HomeMy WebLinkAbout120 Rockhill Dr; 17-2182; ROOFJUL 1'R 2017 4
CITY OF SANFORD
BUILDING & FIRE PREVENTION
PERMIT APPLICATION
Application No: I L'
Documented Construction Value: $ 47 SD
Job Address: 120 Rockhill Drive, Sanford, FL 32771 Historic District: Yes No X
Parcel ID: 33-19-30-516-0000-1300 Residential X Commercial
Type of Work: New Addition Alteration El Repair Demo Change of Use Move
Description of Work: Re -roof with asphalt shingles SQ.
Plan Review Contact Person: Michael E. Torres Title: Owner
Phone: 407-574-4856 Fax: 407-831-7663 Email: Info@ RoofProsUSA.com
Property Owner Information
Name Deborah L Petty Phone: 407-463-2348
Street: 120 Rockhill Drive Resident -of property? Yes-
City, State Zip:• Sanford, FL 32771 '
4 "Contractor Information, _...
Name Roof Pros USA, LLC. Phone: 407-574-4856
Street: 794 Big Tree Drive, Unit 106 Fax: 407-831-7663
City, State Zip: Longwood, FL 32750 State License No.: CCC1326640
Architect/Engineer Information
Name:
Street:
City, St, Zip:
Bonding Company:
Address:
Phone:
Fax:
E-mail:
Mortgage Lender:
Address:
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF
COMMENCEMENT.
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction
in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools,
furnaces, boilers, heaters, tanks, and air conditioners, etc.
FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 51h Edition (2014) Florida Building Code
Revised: June 30, 2015 Permit Application
A
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be
found in the public records of this county, and there may be additional permits required from other governmental entities such as water
management districts, state agencies, or federal agencies.
Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713.
The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required
in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal.
The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in
accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value,
credit will be applied to your permit fees when the permit is issued.
OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will
be done in compliance with all applicable laws regulating construction and zoning.
SignatureofOwner/Agent Date Signat re of Con
Deborah L Petty Michael E. Torres
Print Owner/Agent's Name Print Contractor/Agent's Name
A
g, /,% k -7- 57-4
Signature of Notary -State of Florida Date
NILDA R PRICE
ALFREDO ALVA My COMMISSION # GG076912
MY COMMISSION M FF902162 '•;'' EXPIRES February 26, 2021
EXPIRES JWy 22.2019
Owner/ t s' 4n
e or Contractor/Agent is (Cersonally Known to Produced
ID Type of ID Ft-N- Produced ID Type of ID BELOW
IS FOR OFFICE USE ONLY Permits
Required: Building Electrical Mechanical Plumbing Gas Roof Construction
Type: Total
Sq Ft of Bldg: Occupancy
Use: Min.
Occupancy Load: New
Construction: Electric - # of Amps Fire
Sprinkler Permit: Yes No APPROVALS:
ZONING: ENGINEERING:
COMMENTS:
of
Heads UTILITIES:
FIRE:
Flood
Zone: of
Stories: Plumbing - #
of Fixtures Fire
Alarm Permit: Yes No WASTE
WATER: BUILDING:
Revised:
June 30, 2015 Permit Application
11011101111111111111 ME 1111111111111
THIS INSTRUMENT PREPARED BY:
Name: `-.Michael E. Torres
Address: 794 Ek. "free Drive, Unit 106
Longwood, FL 32750
NOTICE OF COMMENCEMENT
Permit Number: 1 —1;L 19
Parcel ID Number: 33-19-30-516-0000-1300
GRANT I ALOYe SEIIIHOLE COUNTY
CLERK OF' CIRCUIT COURT & COI'IF'TROLL-ER
BK 8951 Po 726 (1F'3s )
CLERK'S y 2017070457
RECORDED 071/1.2(21 1.7 1l.' = till
RECiia,' IJNG FEES $10.00
RIORDED BY hd avor:-2
The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the
following information is provided in this Notice of Commencement.
CERTIFIED COPY - GRANT MALOY.,
1. DESCRIPTION OF PROPERTY: (Legal description of the property and street address if available) CLERK OF THE CIRCUIT COURT
l=fit120RockhillDrive, Sanford. FL 32771 A KIN rnNAnTnn1 f Ca
Lot 130 Country Club Park PH 2, PB 54 PGS 22 THRU 24 cFnmNni r rnl ,wri n nlztns
2. GENERAL DESCRIPTION OF IMPROVEMENT: BY `!vv I
REROOF WITH ASPHALT SHINGLES r10010 79
3. OWNER INFORMATION OR LESSEE INFORMATION IF THE LESSEE CONTRACTED FOR THE IMPROVEMENT:
Name and address: Deborah L. Petty - 120 Rockhill Drive Sanford FL 32771
Interest in property: Owner
Fee Simple Title Holder (if other than owner listed above) Name:
4. CONTRACTOR: Name: Roof Pros USA, LLC Phone Number: 407-574-4856
Address: 794 Big Tree Drive, Unit 106, Longwood, FL'32750
6. SURETY (If applicable, a copy of the payment bond is attached): Name:
6. LENDER:
Address:
Phone Number:
Amount of Bond:
7. Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served as provided by Section
713.13(1)(a)7., Florida Statutes.
8. In addition, Owner designates
Phone Number:
of
to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Phone number:
9. Expiration Date of Notice of Commencement (The expiration is 1 year from date of recording unless a different date is specified)
WARNING TO OWNER. ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE
CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE
JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY
BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.
Under penalties of perju , I decl a that 1 have read the foregoing and that the facts stated in it are true to the best of my knowledge and
belief.
o - r
Signalu?e-DY er or essee, or Own r Lessee's (Print Name and Provide Signatory's Title/Orrice)
Authorized Officer/Director,ner M ager)
state of Florida county of Seminol
The foregoing instrument was acknowledged before me this s— day of _ —To L-r , 2017
by U0&D r..49 Who is personally known tome OR
Name of person making statement
who has produced identification IN type of identification produced: rbcs
ALFDO ALVA
MY COM 'IS ION # FF902162 -- Notary signature
EXPIRES July 22.2019
407) 308-0'53 FWWNouySer ict.corr
Y CLERK
A77/
1(
PERMIT # ) -1 'j1 22 City
of Sanford Building Division Residential
Re -Roof Scope of Work JOB
ADDRESS: 120 Rockhill Drive, Sanford FL 32771 STRUCTURE
TYPE: Q SINGLE FAMILY RESIDENCE/TOWNHOUSE O MOBILE HOME O APARTMENT/CONDOMINIUM RE -
ROOF TYPE: Q REPLACEMENT (TEAR OFF EXISTING ROOF AND REPLACE WITH NEW COMPONENTS) O
RE-COVER (NEW ROOF INSTALLED OVER EXISTING ROOF) DECK
TYPE (PLEASE SPECIFY): Wood Deck - Plywood PLEASE
NOTE: ONL Y IOO SQUARE FEET OF THE EXISTING DECK IS PERMITTED TO BE REPLACED ROOFVENTILATION:
OOFF-RIDGE RIDGE OSOFFIT OPOWERED VENT OTURBINES SKYLIGHTS:
OYES (2) NO IF YES, PLEASE PROVIDE FLORIDA PRODUCT APPROVAL #: MAIN
ROOF AREA ROOF
SLOPE: O LESS THAN 2:12 O 2:12 - 4:12 r'4:12 OR GREATER TYPE
OF ROOF MANUFACTURER FLORIDA PRODUCT APPROVAL SHINGLE
CertainTeed FL# 5444-R10 O
METAL FL# O
MODIFIED BITUMEN FL# OTORCH
DOWN FL# O
INSULATED FL# O
TILE FL# Z)
OTHER: V (1 oC FiLL W FL# 15-Z j - I
v ROOF
EXTENSIONS (PORCHES, PATIOS, ETC.) **IFAPPLICABLE**,ram
ROOFSLOPE: O LESS THAN 2:12 O 2:12 — 4:12 V 4:12 OR GREATER TYPE
OF ROOF MANUFACTURER FLORIDA PRODUCT APPROVAL O
SHINGLE FL# O
METAL FL# O
MODIFIED BITUMEN FL# OTORCH
DOWN FL# O
INSULATED FL# O
TILE FL# O
OTH ER: F L#
CUSTOMER AGREEMENT J CONTRACT PROPOSAL
RoofProsUSA.com
ROOF PROS USA, LLC
CORPORATE HEADQUARTERS
794 Big Tree Drive / Unit 106
Longwood, FL 32750
PH: 866-407-0250 • FX: 407-831-7663
Serving:
Orlando: 407-574-4856
Jacksonville: 904-371-3235
South FL: 954-234-2616
FL Lic. #CGC1507133
FL Lic. #CCC1326640
Customer Name: f e— Date:
Job Address: 4-,96/'—
City / State: ? e Zip: 3 2 7"7—t
Cell Phone: 5'--c 3 3 547 Home Phone: Email:
Insurance Company Pcr'i Y2s Claim No.: Policy No.: =5
1
ROOF SPECIFICATIONS
one layer of roof materials and dispose.
OTHER PROPERTY CONDITIONS
Existing Driveway Damage: Yes NoUpemove
IyJ/Re-nail existing deck to meet uplift codes.
7 Install painted metal drip edge around perimeter of roof.
Skylights:
Interior Damage:
Install boots to pipes 11/2" 2" 3"
LJJN /IInstall Gooseneck vents 4" 101,
LYApply ASTM D226, UL underlayment to wood deck.
Emergency Repair
WORK INCLUDES:
Remove trash from roof gutters and yard Furnish Permit
LN .Apply METAL /SHINGLES /TILE /SHAKES /FLAT ROOF SYSTEM
LH Style of roof to be installed:
Color: Pitch:
UInstall ridge or off ridge vents Qty: Size:
d $80 per sheet of plywood (or $5/ft for <10" wide deck boards)
Protect landscaping where applicable 2 Year Warranty
Roll yard with magnetic roller
UPGRADE RECOMMENDATIONS / NOTES
if decking replacement is needed.
TOTAL INVESTMENT SUMMARY
We propose to furnish material and labor
in accordance with the specifications above.
Insurance Proceeds + Deductable: c o
Change Orders / Upgrades:
TOTAL COST: Ins. Proceeds + Deductible + Change Orders / Upgrade:
ACCEPTANCE OF AGREEMENT: This Agreement DOES NOT OBLIGATE THE CUSTOMER OR ROOF PROS USA, LLC IN ANY WAY
UNLESS PAYMENT FOR DAMAGE IS APPROVED BY THE INSURANCE COMPANY AND ACCEPTED BY ROOF PROS USA, LLC.
By signing this agreement, Customer hereby grants the right and authority to ROOF PROS USA, LLC to do the following:
a) To cooperate with Customer's insurance company for insurance proceeds for the restoration of the damage covered by the insurance proceeds, with
the intent to have Customer's requested work paid by the insurance proceeds at no additional cost to Customer except for Customer's insurance policy
deductible and those items that Customer's insurance policy excludes for coverage. Customer agrees to payfor all items excluded by Customer's insurance
policy. Roof Pros USA, LLC will provide customer with a cost break down of those itemsexcluded from the insurance policy after that information is made
known to Roof Pros USA, LLC.
b) To request payment from customer's insurance company for items not included in the Insurance Company's estimate. All monies received from the
insurance company as contractor overhead and profit and/or cost increase supplements will be paid to ROOF PROS USA, LLC.
c) IF THIS CONTRACT IS CANCELLED BY THE CUSTOMER LATER THAN MIDNIGHT ON THE 3rd BUSINESS DAY from execution, customer shall pay to
RPUSA twenty percent (20%) of the insurance proceeds or $2,000.00, whichever is greater, as liquidated damages -not -as,,_ enalty, and RPUSA agrees to
accept such as a reasonable and just compensation for said cancellation.
Accepted by Property Owner: Date:A / 1 5/ r
Accepted by ROOF PROS USA, LLC: Date: / / By:
Sales Representative: Date://_ By:
O
ALL PAYMENTS SHOULD BE MADE TO ROOF PROS USA, LLC - NOT THE SALESMAN
TERMS AND CONDITIONS OF SERVICE
1. The services that ROOF PROS USA, LLC, hereinafter referred to as RPUSA, will provide are limited to those specifically described herein. The services
described here in constitute a comprehensive specification that expressly excludes any and all services not specifically described in thiscontract. RPUSA's
performance of the services is limited by, among other things, the pre-existing conditions and characteristics of the premises. RPUSA EXPRESSLY DISCLAIMS
ANY RESPONSIBILITY OR LIABILITY FOR ANY PRE-EXISTING OR HIDDEN CONDITIONS KNOWN ORUNKNOWN. Customer shall retain responsibility and
shall be liable for all effects of and costs necessary to correct such situations. In the event that a party other than RPUSA makes corrections while RPUSA is
performing its work, RPUSA shall be entitled to stop work and receive payment for the percentage of the work completed to date. RPUSA may resume the
project once the condition has been rectified.
2. All contracts are subject to approval of our credit department and office without exception. The person executing this contract must obtain the approvalof an
officer of RPUSA for this contract to be effective under any conditions in the state of record.
3. IF THIS CONTRACT IS CANCELLED BY THE CUSTOMER LATER THAN MIDNIGHT ON THE 3RD BUSINESS DAY from execution, customer shall pay to
RPUSA twenty percent (20%) of the insurance proceeds or $2,000.00, whichever is greater, as liquidated damages, not as a penalty, and RPUSA agrees to
accept such as a reasonable and just compensation for said cancellation. For the cancellation to be effective, notice must be sent via certified mail to RPUSA.
Client understands this 20% is for inspection services, estimating, travel expenses and working with adjuster to win the claim.
4. CUSTOMER ACKNOWLEDGES AND AGREES THAT MOLD IS COMMONLY FOUND THROUGHOUT THE ENVIRONMENT AND AGREES TO HOLD
HARMLESS AND INDEMNIFY RPUSA FROM ANY CLAIMS ARISING OUT OF OR RELATING TO INDOOR AIR QUALITY, MOLD, FUNGUS, SPORES
OR OTHER ORGANISMS WHETHER EXISTING OR A FUTURE CONDITION REGARDLESS OF WHETHER IT MAY BE ASSOCIATED WITH DEFECTS IN
RPUSA'S CONSTRUCTION OR SERVICES, INCLUDING BUT NOT LIMITED TO PROPERTY DAMAGE, PERSONAL INJURY, LOSS OF INCOME, EMOTIONAL
DISTRESS, DEATH, LOSS OF USE, LOSS OF VALUE, ADVERSE HEALTH EFFECTS OR ANY SPECIAL, CONSEQUENTIAL, PUNITIVE OR OTHER DAMAGES.
5. If hidden and unknown conditions are encountered at the site which are either (1) materially different from those indicated in this agreement or (2) materially
different from those ordinarily found to exist and generally recognized as inherent in construction activities of the character provided for in this agreement,
then notice by the observing party shall be given to the other party promptly before conditions are disturbed and in no event later than 21 days after the first
observance of the condition(s). The Customer and RPUSA will promptly investigate such condition and will negotiate for an equitable adjustment to the contract
amount, contract time or both.
6. Customer hereby authorizes RPUSA to make all openings necessary to perform this Contract, and RPUSA will close such openings in a workmanlike manner.
Customer acknowledges that it is often not possible to exactly match existing colors, textures and the like. Customer understands and agrees that RPUSA is
not responsible for evaluating design factors including but not limited to venting and circulation systems and that vents and soffits will be installed according
to Florida Building Codes.
7. CUSTOMER UNDERSTANDS AND AGREES THAT RPUSA WILL NOT BE RESPONSIBLE FOR ANY SPECIAL INDIRECT, PUNITVE, SPECULATIVE,
CONSEQUENTIAL DAMAGES OR FOR ANY PENALTIES REGARDLESS OF THE LEGAL OR EQUITABLE THEORY ASSERTED INCLUDING ANY DAMAGE
CAUSED BY SETTLEMENT, VIBRATION, DISTORTION, WATER INTRUSION OR FAILURE OF THE FOUNDATION ON WHICH THE ROOF RESTS, OR DAMAGE
CAUSED BY HAIL, HURRICANES, GALE WINDS, UNUSUAL WEATHER CONDITIONS OR ACTS OF GOD NOR FOR ANY DAMAGE OR DELAYS DUE TO
STRIKES, FIRES, ACCIDENTS, BAD WEATHER, OR OTHER CAUSES BEYOND RPUSA'S CONTROL; NOR FOR INHERENT DEFECTS IN THE PREMISES ON
WHICH THE WORK IS TO BE DONE AND IN NO EVENT SHALL RPUSA BE RESPONSIBLE FOR INTERIOR OR EXTERIOR DAMAGE TO THE BUILDING, ITS
CONTENTS OR SURROUNDING PROPERTY.
8. The contract is based on the fact that RPUSA will have direct access to the eave of the roof for heavy trucks and equipment unless otherwise stated. If such
access to the eave of the roof is over the existing driveway or lawn, RPUSA will not be responsible for any damage that may occur as a resultof the weight of
equipment and vehicles even if protection is provided. Protection of driveways, pavers and lawns or other means of access will be provided only if expressly
included in RPUSA's scope of work. Although RPUSA may cover any brick pavers or stamped concrete driveway with wood planking during the course of work,
customer understands and agrees that RPUSA will not be responsible for any damage that may occur as a resultof the weight of its equipment or vehicles.
9. If skylights are present and RPUSA is not paid and/or contracted to install new skylights, RPUSA shall not be held liable for any leaks or issues relating to
existing skylights and/or existing flashing even if they had to be removed and re -installed by RPUSA in order to complete RPUSA's work. RPUSA recommends
that Customer purchase new skylights in order to avoid any problems.
10. If decking is required but not covered by your policy it will be replaced and you agree to pay RPUSA $80 per sheet of plywood decking and $5.00 per lineal
foot for <10" wide deck boards repaired for plank decking. Price may fluctuate depending on size and type of wood.
11. If re -nailing of your roof sheathing to the trusses is required but not covered by your policy it will be replaced and you agree to pay RPUSA $0.25 per square
foot. In addition, Customer is responsible for any and all engineering fees if required by the city and covered by the insurance policy.
12. Section 489.126, Florida Statutes provides that: A contractor who receives, as initial payment, money totaling more than 10 percent of the contract price for
repair, restoration, improvement, or construction to residential real property must: (a) Apply for permits necessary to do work within 30 days after the date
payment is made, except where the work does not require a permit under the applicable codes and ordinances, and (b) Star t the workwithin 90 days after the
date all necessary permits for work, if any, are issued, unless the person who made the payment agreed, in writing, to a longerperiod to apply for the necessary
permits to start the work or to longer periods for both. Customer hereby agrees that Customer and RPUSA havediscussed the time required to obtain permits
for the work and the time required to actually start the work. Customer agrees that RPUSA may takelonger for both periods, provided that reasonable efforts
will be made by RPUSA to perform its contractual obligations in a timely manner.
13. RPUSA shall not be liable for failure of performance due to labor controversies. Strikes, fires, weather, inability to obtain materials from usual sources, or any
other circumstances beyond the control of RPUSA.
14. Customer agrees to fully cooperate with RPUSA to secure any licenses, permits or any other authorization necessary to accomplish the work. Customer hereby
appoints RPUSA as its agent to procure said licenses, permits or authorizations.
15. RPUSA will provide Customer with a two (2) year limited warranty, which shall be limited to repair or replacement of defective material or defective workman-
ship. Customer agrees that the decision of whether to repair or replace the defective material or defective workmanship will be based solely and exclusive on
RPUSA's professional discretion. RPUSA will not be liable for any damage to the roof or below the roof due to wind, condensation, hail, thunderstorms, rain,
ice or any other Act of God during the warranty period.
16. RPUSA shall be entitled to a charge of 1.5 % per month on all balances left owed over 30 days. Should legal action be brought under the terms of this Contract
or arise out of the performance of the Services referenced herein, or should the matter be turned over for collection, RPUSA shall be entitled to the fullest extent
permitted under the law to all costs of collection, including but not limited to reasonable attorney's fees.
17. This Agreement contains the entire agreement of the parties. Customer agrees and acknowledges that no representations or warranties of any kindhave been
made by RPUSA or its employees other than those expressed herein. All prior agreements respecting the subject matter thereof have been incorporated in the
terms herein and are no longer of any force or effect. All modifications to this Agreement shall be in writing and signed by both parties.
18. CHOICE OF FORUM/CHOICE OF LAW: The validity and affect of this Agreement shall be governed by and construed and enforced exclusively in accordance
with the laws of the State of Florida, without regard to principles of conflicts of laws. The Customer and Roof Pros USA, LLC ("Parties") hereby submit to the
exclusive jurisdiction of any federal or state court sitting in Seminole County, Florida for the purpose of any action arising out of or relating to this agreement
an "Action"), and agree that all such actions shall be heard and determined in such Florida federal court or in such state court. Each of the Parties hereby
irrevocably waivers, to the fullest extent it may effectively do so, the defense of an inconvenient forum to the maintenance of any Action in Seminole County,
Florida. The prevailing party in any Action, including appeals, shall be entitled to recover its reasonable attorneys' fees, costs and expenses. The Parties waive
their respective rights to a trial by jury for any Action.
19. Every provision of this Agreement is intended to be severable. If any terms or provision hereof is found by a Court of competent jurisdiction to be invalid, such
invalidity shall not affect the validity of the balance of the Contract or the remaining terms and provisions hereof.
20. ANY CLAIMS FOR CONSTRUCTION DEFECTS ARE SUBJECTS TO THE NOTICE AND CURE PROVISIONS OF CHAPTER 558 FLORIDA STATUTES.
21. Customer has been provided with a Project Review Checklist. Customer has read the project Review Checklist and agrees to be bound by its terms and
conditions.
D `
City of Sanford Building Division
Residential Re -Roof Inspection Policy & Procedures
PERMITTING REQUIREMENTS —NO PLAN REVIEW REQUIRED
This document (signed) along with an accurate and completed Residential Re -Roof Scope of Work are required
to be submitted as part of your permit application.
The Scope of Work must include all applicable Florida Product Approval numbers for all roof components that
will be installed on the project.
A permit will not be issued without these documents. Copies will be made to post on the job site.
Projects located in the Sanford Historic District will require plan review and approval by the Sanford
Historic Preservation Board
INSPECTION POLICY & PROCEDURES
A Final Roof Inspection is the only inspection required for Residential (Single Family, Townhouse, Mobile
Home, Apartment and/or Condominium) Re -Roof Permits.
The Following is required to be provide on the job site:
Permit Card, posted in a conspicuous and weatherproof location
Completed Residential Re -Roof Scope of Work
Completed and Notarized Inspection Affidavit
All Florida Product Approval and Corresponding Installation Instructions
Product Approval shall match what is on the scope of work)
Digital Photographs (must include the permit number or address in each picture)
o Each plane of the roof, showing the underlayment installed
o Roof Deck Nailing Pattern & Spacing (including a measuring device or ruler)
o Roof Deck Nails used, (including a measuring device or ruler showing size of nails)
o Underlayment Pattern & Spacing (including a measuring device or ruler)
o Drip Edge & Valley Attachment (including a measuring device or ruler)
o Shingles installed, nail pattern and location of nails
Skylights (if applicable)
o Digital photographs showing all installation components, per FL Product Approval
o Digital photographs showing all required flashing, per FL Product Approval
Failure to follow these specific guidelines will result in an affidavit provided by a Florida Design
Professional (architect or engineer), certifyin FBC cod compliance by personal inspection.
CONTRACTOR (OR OWNER/BUILDER) SIGNATURE: _ DATE:
l
LIMITED POWER OF ATTORNEY
Altamonte Springs, Casselberry, Lake Mary, Longwood, Sanford,
Seminole County, Winter Springs
Date: Julv 7, 2017
I hereby name and appoint J/W,* 7r; CF-
an agent Of: ROOF PROS USA, LLC
Name of Company)
to be my lawful attorney -in -fact to act for me to apply for, receipt for, sign for and do all things
necessary to this appointment for (check only one option):
Lxl The specific permit and application for work located at:
120 Rockhill Drive, Sanford, FL 32771
Street Address)
Expiration Date for This Limited Power of Attorney:
License Holder Name: Michael E . Torres
State License Number:
Signature of License H
STATE OF FLORIDA
COUNTY OF Seminole
CCC1326640
July 7, 2018
The foregoing instrument was acknowledged before me this 13 day of July
20017 , by Michael E. Torres who is Rg personally known
to me or who has produced as
identification and who did (did not) take an oath.
ee
a
Signature
Notary Sea])
Print or type name
t r Patricia Choate Notary Public - State of Florida
NOTARY PUBLIC Commission No. Ei GO yN 53$
STATE OF FLORIDA My Commission Expires: titZ ZdZ pComm# GG044538
Expires 11/2/2020
Rev. 08.12)
SCPA Parcel View: 33-19-30-516-0000-1300
Property Record Card
DP*
HF
P SR Parcel: 33-19-30-516-0000-1300
Owner: PETTY DEBORAH L
lntew,xLtJot:rrrv,tt5trgA .
Property Address: 120 ROCKHILL DR SANFORD, FL 32771
Parcel Information Value Summary
Parcel
Owner
33-19-30-516-0000-1300
PETTY DEBORAH L
Property Address 120 ROCKHILL DR SANFORD, FL 32771
Mailing 1875 CYPRESS AVE ORANGE CITY, FL 32763-8730
Subdivision Name COUNTRY CLUB PARK PH 2
Tax District
DOR Use Code
S1-SANFORD
01-SINGLE FAMILY
Exemptions
9
e•
Seminole•
Legal Description
LOT 130
COUNTRY CLUB PARK PH 2
PB 54 PGS 22 THRU 24
Taxes
Page 1 of 2
2017 Working 2016 Certified
Values Values
Valuation Method Cost/Market Cost/Market
Number of Buildings 1 1
Depreciated Bldg Value 129,867 120,494
Depreciated EXFT Value 1,150 1,200
Land Value (Market) 38,000 32,000
Land Value Ag
Just/Market Value ** 169,017 153,694
Portability Adj
Save Our Homes Adj 0 0
Amendment 1 Ad/ 6,445 5,901
P&G Ad/ 0 0
Assessed Value 162,572 147,793
Tax Amount without SOH: $3,007.00
2016 Tax Bill Amount $3,007.00
Tax Estimator
Save Our Homes Savings: $0.00
Does NOT INCLUDE Non Ad Valorem Assessments
Taxing Authority Assessment Value Exempt Values Taxable Value
I County General Fund 162,572 00 162,572
Schools 169,017 0 169,017
City Sanford 162,572: 0 162,572
SJWM(Saint Johns Water Management) I $162 572 0 162,572
County Bonds 162,572 1 0 162,572
Sales
Description Date Book Page Amount Qualified Vac/Imp
SPECIAL WARRANTY DEED 3/1/2000 103831 0097 $112,200 Yes Improved
WARRANTY DEED 12/1/1999 03791 1138 $23,5001 Yes Vacant
Find Comparable Sales
Land
Method Frontage Depth Units Units Price Land Value
LOT 1 38,000.00 38,000
Building Information
Is Bed/Bath count incorrect? Click Here.
Description Year Built Fixtures Bed Bath Base Area Total SF Living SF Ext Wall Adj Value Repl Value Appendages
Actual/Effective
1 SINGLE 2000 7 3 2_0 1,462 1 2,070 1,462 CB/STUCCO $129,867 138,156
Description Area
FAMILY FINISH
GARAGE I
411.00
FINISHED
http://parceldetail.scpafl.org/ParcelDetailInfo.aspx?PID=33193051600001300 7/18/2017
CITY OF SANFORD BUILDING SERVICES
Residential Re -Roof
Hurricane Mitigation Inspection Affidavit
Permit4:
l Michael E. Torres hereby acknowledge that I personally inspected
Roof deck nailing and/or Secondary water barrier work
at 120 Rockhill Drive, Sanford FL 32771 and have determined that the work
Job Site Address)
was done according to the Hurricane Mitigation Retrofit Manual. (based on 553.844 F.S.)
I certify that my statements herein are true and accurate to the best of my belief and that I fully
understand that making any false statements in writing with the intent to mislead a public servant in the
performance of his or her official duty shall constitute a misdemeanor of the second degree pursuant to
Section 8137.06 F.S
Signature, of Contr 51 Date
Michael E Torres
i'rinted Name of Contractor
CCC1326640
License
License Typc: General Building Residential (Roofing Contractor)
or any individual certified in accordance with F.S. 468 to make such an inspection.
STATE OF FLORIDA COUNTY OF Seminole
Sworn to (or affirmed) and subscribed before me this a day of --Tv C _, 2017 , by
Michael E. Torres , who is (Personally Drown to me)or has Produced (type of
identif=t') as identification.
SL'AL)
Signature of Notar Public
State of Florida F,.V e. NILDA R PRICE
Print/Type/Stamp Name ; MY COMMISSION # GG076912
of Notary Public EXPIRES February 26, 2021