Loading...
HomeMy WebLinkAbout2445 Washington St; 17-2302; SOLARD b5 CITY OF SANFORD BUILDING &FIRE PREVENTION jjj PERMIT APPLICATION F . , JUL 2 7 2017 Application No: Documented Construction Value: $ r lP . 05 Job Address: c2yg5 UJa1\g(A0(la - Soakfl IL, 3Q ) 1 Historic District: Yes No Parcel ID: ` `- 1 ( - Q -'0036 Residential Q Commercial Type of Work: New Addition Alteration ® Repair Demo Change of Use Move Description of Work: Insly-M S&a_ W 0__MSAP_rn y V1('J on C)C\Sykr"G Plan Review Contact Person: Mal " l \ll Title: Phone: 40-1-9a-165- Fax: (-i-1d-(, Email:Y Property Owner Information s Name 50(_Na%Ckn 'e.eUef Phone: -10-1 -3) - Ot Street: 1_6 6 Resident of property? : 4e City, State Zip: OC f'L a Contractor Information Name &) Ae`lClf`(1 ) -ey A IC .-IC1c Phone: 1A0 -_7 51 Street: 6sW . sm"A\S"\ . G Fax: 01QQ— QD 9 City, State Zip: ©r \Q c),31 State License No.: tc opo l q Name: Street: City, St, Zip: Bonding Company: Address: Architect/ Engineer Information Phone: Fax: E- mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. ( I FBC 105. 3 Shall be inscribed with the date of application and the code in effect as of that date: 5" Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information accurate be done in compliance with all applicable laws regulating constructio and zpfiill July 6, 2017 Signature of Omer/Agent Date Jondhan Beever Pont rvner nt's Nan ignature of Notary -State of • onda Date 40 Florida LeshNotRDEdfMy74541 Expi Owner/Agent is Produced ID — Type of I Signature or Contractor/Agen M(1,(k S; that all work will bate Pn Contractor nt's Name Signatureroviv I' F1 n a D•Ile Notary Put,1 °:z of Florida Leslie Jo ,. ::yh My Comm;-: :,;n FF 174541 Expirestu 12nig Contractor/Agent is 4t'leivtrtb Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing Gas Roof Construction Type: Total Sq Ft of Bldg: Occupancy Use: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: Yes No # of Heads _ APPROVALS: ZONING: ENGINEERING: COMMENTS: UTILITIES: FIRE: Flood Zone: of Stories: Plumbing - # of Fixtures. Fire Alarm Permit: Yes No WASTE WATER: BUILDING: S; 8,14-0 Revised June 30. 2015 Permit Application Form 208 - Rev. 2111 - MPS Ronda Imm MASTER PRINTING SERVICES. INC. (407) 473-9448 SOLAR=`SOL'UTIIONS LLC s z'.i 1537 W. Smith Street 9 Orlando, Florida :/- 4/ / 9/ Proposal/Contract State Lic: CAC057411 • EC0001898 • CVC56861 www.bobheinmillersolarcom SUBMITTED TO PHONE DATE R Jonathon Beever 407-319-0163 6/22/17 0 STREET JOB NUMBER OR NAME P 2445 Washington Ct Solar Electric Installation 0 CITY STATE ZIP JOB LOCATION s Sanford FL 32771 Beeverj@gmail.com L MAIN CONTACT JOB PHONE Mike Lane 1415-688-0161 WE RESPECTFULLY SUBMIT THE FOLLOWING SPECIFICATIONS AND ESTIMATE FOR: SOLAR ELECTRIC INSTALLATION SYSTEM==4.35KW 15) Hyundai 29OW PANELS 1 SOLAREDGE 5000W INVERTER 15) P300 SOLAREDGE OPTMIZERS EQUIPMENT, LABOR, PERMITTING = $12,895 QUALIFIES FOR 30% FEDERAL TAX CREDIT INCLUDES MONITORING OF PANEL AND OPTMIZER WARRANTY: HYUNDAI WARRANTY 10 YEAR PRODUCT WARRANTY, 25 YEAR PERFORMANCE GAURAUNTEE MANUFACTURERS WARRANTY 12 YEARS ON INVERTER, 25 YEARS OPTIMIZERS BOB HEINMILLER WARRANTY: 1 YEAR PARTS AND LABOR WE OFFER TO FURNISH MATERIAL AND LABOR AND COMPLETE THE ABOVE IN ACCORDANCE WITH ABOVE SPECIFICATIONS FOR THE SUM OF: TWELVE THOUSAND EIGHT HUNDRED AND NINETY FIVE 00/100-------- © DOLLARS ($ 12,895 PAYMENT TO BE MADE AS FOLLOWS: -7 5/I7 a TJ_ ` 6-650% DEPOSIT 50% UPON COMPLETION 'l,,r1 All material is gua ra meed to be as specified. All work to be completed in a workmanlike manner IF according to standa rd practices. Any alteration or deviation from above specifications involving Mike LaneextracostswiIIbeexeculedonlyuponwrittenorders, a nd wi I I become a n extra cha rge over a nd AUTHORIZED SIGNATURE above the estimate All agreements contingent upon strikes, accidents or delays beyond our con- OFFER MAY BE WITHDRAWNtrol. Owner locally fire, tornado, and other necessary insurance. Ourworkers arefullycovered by Workman'sCompensalion Insurance. IF NOT ACCEPTED WITHIN 20 DAYS. C The above prices, specifications and conditions arc satisfacto and are hereby accepted. You are authorized to do thXRIZEDSIGNATURE Payne will be made as outlined above. C E P CN C AUTHORIZED GNATURE DATE OF ACCEPTANCE THIS INSTRUMENT PREPARED BY: Name: Kimberly Killian Address: 1537 W. Smith St. Orlando. FL 32804 NOTICE OF COMMENCEMENT State of Florida County of Seminole GRANT MALOYr SENINOLE COUNTY CLERK OF CIRCUIT COURT & CONPTROLLER BK 8961 Ps 422 (1Pss) CLERK'S T 2017076205 RECORDED 07/27/2017 03:00.255 P11 RECORDING FEES $10.00 RECORDED BY hdevore Permit Number. Parcel ID Number: 31-19-31-524-0300-0030 The undersigned hereby gives notice that improvement will be made to certain real property and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. DESCRIPTION OF PROPERTY: (Legal description of the property and street address if available) LOTS 3 & 4 BLK 3 WYNNEWOOD PB 4 PG 92 GENERAL DESCRIPTION OF IMPROVEMENT: TextInstallSolarPVSystem4.35 kw OWNER INFORMATION: Name: Jonathan Beaver and Laurie A. Pinkert Address: 2445 Washington Ct, Sanford, FL 32771 Fee Simple Title Holder (if other than owner) Name: NA Address: NA CONTRACTOR: Name: Bob Heinmiller A/C, Inc. Address: 1537 W. Smith St, Orlando, FL 32804 Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served as provided by Section 713.13(1)(b), Florida Statutes. Name: NA Address: NA In addition to himself, Owner Designates NA NA To receive a copy of the Lienor's Notice as Provided in Section 713.13(1)(b), Florida Statutes. Expiration Date of Notice of Commencement (The expiration date is 1 year from date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1. SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalties of perjury, I declare that 1 have read the foregoing and that the facts stated in it are true to the tof my wledge and bell r -- It- (J Jonathan Beaver and Laurie A. Pinkert Owner' s'Slgneture Owner's Printed Name Fonda Statute 713.13(1)(g) '7he owner must sign the notice of commencement and no one else may be permitted to sign in his or her stead.' State of F County of 0 VlJtl"` a The foregoing Instrument was acknowledged before me this day of 20 1 / s `'• t s,;.; \Jby Who Is personally known to me A,- C Nameofpersonmakingstatement > O OR who has produced Identification type of Identification oduced: 11/ 26/S2018 te of Florida ough Notary Signature . FF 174541 18 P I Ow_ barl, the 0 wn-c Special Power of Attorney title), of e of i Licenpe Holder), IWhereinafte Y r referred to as the "License Holder," 0 T Li-'Q(M 1 tk L (Name of Company), hereinafter referred to as the "Company", hereby appoint the following persons as Attorney -in -Fact of the License Holder/ Company, in order to (a) sign and submit b Iuildi/(y 1 y(_ permit applications, (b) obtain building permits JOV11( tTkAA, 0 L J WGiO _ GU-r 4z--------------- 7i/— Title: Company Name: b,,, Mnilinr, Address:" Telephone No.: VO? • Ka •_7 O,K Fax No.: q(l 7 Z_2, • ()-fib State ofCountyof WITNESSES: /, Sign: / . Print Name: Sign: Print Name: E-mail Address: bhp g o-PT rrL("w V&f The foregoinginstrumentwasacknwiededbeforepiiss ",-j of 20, by , the ( (/ of ['' corporation, on behalf of the corporation. He/ she is personally known to me or has produc as identification. L Notary Public State of Florida Leslie Joyce Keough Notary Public ,/ p My Commission FF 174541 // ev Y 0 pd" Expires 11/26/2018 Commission Expires: REQUIRED INSPECTION SEQUENCE BP# - 230Z BUILDING PERMIT min Maxi IIns ection Description Footer / Setback Stemwall Foundation / Form Board Survey Slab / Mono Slab Prepour Lintel / Tie Beam / Fill / Down Cell Sheathing — Walls Sheathing — Roof Roof Dry In Frame Insulation Rough In Firewall Screw Pattern Drywall / Sheetrock Lath Inspection Final Solar Final Firewall Final Roof Final Stucco / Siding Insulation Final Final Utility Building Final Door Final Window Final Screen Room Final Pool Screen Enclosure Final Single Family Residence Final Building (Other) Address: Z!W C-1- ELECTRICAL -PERMIT Min Max IIns ection Descri tion Electric Underground Footer / Slab Steel Bond Electric Rough T.U.G. Pre -Power Final Electric Final Y" 'frs'9w\Y Sn.+r, a'.Y.4i+'.t :v.<'%tz:"s..'-.A/' ' YL+rJ"i i8 . Y i A .H \ Min Maxi IInns ection Descri tion Plumbing Underground Plumbing Sewer Plumbing Tub Set Plumbing Final MtCHANICA'L:PERMIT _ Min I Maxi Min I Maxi Mechanical Roug Mechanical Final Gas Unde Gas Roug Gas Final REVISED: June 2014 9 1 249 Maitland Ave Suite 3000 1 Altamonte Springs, Florida 32701 P: (321)972-0491 1 F: (321)972-0484 1 E: info@fdseng.com Website: www.fdseng.com CA# 9161 ENGINEERING ~ASSOCIATES July 26, 2017 Building Department Ref: Bob Heinmiller Air Conditioning, Inc. Project: Solar Array Panels Lot/Block: 3 and 4 Blk. 3 Address: 2445 Washington Court, Sanford, FL 32771 Subdivision: Wynnewood FDS#: 17-0904 To whom it may concern, The above mentioned project has been design in accordance with the following code; 2014 Florida Building Code 51h Edition — Residential Wind Speed 140 Exposure B We have reviewed the UniRac SolarMount — Solar Module Mounting System with the GreenFasten 5/16" stainless steel lag screws with a minimum penetration of 2 1/2" into structural members (not including sheathing) at a maximum spacing of 48" on center. If SolarMount is located on a skewed angle to truss members below, the attachment spacing shall be maximum of 24" with additional blocking, see attached TB 16 Alt. Blocking @ Skewed Roof Slope detail. The 5/16" stainless steel lag screw with minimum penetration of 2 1/2" in structural members is adequate and acceptable for the design uplift loads. This acceptance is limited to the structural components and does not include any product approvals, architectural finishes, subsurface, mechanical, electrical or plumbing. If you have any questions, please do not hesitate to call. Sincerely, Lice n Ca v Bxown, RFC •'• Z FLgE956 2 T,g( 6726 _ a N '••l0 OF If sealed/%n fnre a mrbloor #'t be smudged contact FOR for authorization ll fl i7PNOAK ness with a Service Mindset and an Eye for Detail" y 249 Maitland Ave Suite 3000 1 Altamonte Springs, Florida 32701 P: (321)972-0491 1 F: (321)972-0484 1 E: info@fdseng.com Website: www.fdseng.com CA# 9161 ENGINEERING ASSOCIATES SIMPSON A23CLIP POSTING, SHEATHING SIMPSON A23 CLIP SLOPED', CUT.21 SXP:#2 NAIL TO TOP;CHORD.; OF H(PAED TRUS$;W/.(3) 12d NAIL64 EA. END;.. SPACED 24"- O:C. HP TRUSS TB16 ALT. BLOCKING @ S,KEWED ROOF SLOPE o. dVS6 Carli. rpwn$? FLPF* W2 F a If Seal and *a it aEetVjgOt o,40t be smudged contact FOR for authorization ll9 Illt `\ omg Business with a Service Mindset and an Eye for Detail' SHEET CATALOG: INDEX NO. DESCRIPTION VICINITY Forest Dr T-1 COVER PAGE M-1 MOUNTING DETAILS M-2 STRUCTURAL DETAILS E-1 THREE LINE DIAGRAM PL-1 WARNING PLACARDS SCOPE OF WORK HOM E OWNER: JONATHON BEEVER 2445 WASHINGTON COURT,SANFORD,FL 32771 GENERAL SYSTEM INFORMATION SYSTEM SIZE 4.35kW DC, 5.00kW AC M ODULES: 15) HYUNDAI SOLAR HYUNDAI HiS-S290RG INVERTER 1) SOLARE GETECHNOLCGIESSES000A-US(24OV) BRANCH DETAILS: 1x15 SMES OF STRINGS STRUCTURAL DETAILS MAKRAIL SPANW-0" MAX.POINT LOAD.26.54LBS MAX DISTRIBUTED LOAD:2.81 PSF GENERAL NOTES 1. THE PHOTOVOLTAIC (PV) SYSTEM WILL BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF THE 2011 NATIONAL ELECTRIC CODE (NEC) AND 2014 FLORIDA BUILDING CODE(FBC) ARTICLE, ALL MANUFACTURERS'S LISTING AND INSTALLATION INSTRUCTIONS AND THE RELEVANT CODES AS SPECIFIED BY THE AUTHORITY HAVING JURISDICTION'S (AHJ) APPLICABLE CODES. 2. CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(E). 3. THIS SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND THE AUTHORITY AND THE UTILITY COMPANY ARE OBTAINED. 4. ALL PV SYSTEM COMPONENTS ARE IDENTIFIED AND LISTED FOR USE IN PHOTOVOLTAIC SYSTEMS AND REQUIRED BY NEC 690.4 & NEC 690.60: PV MODULES: UL1703,IEC61730 AND IEC61215 & NFPA 70 CLASS C FIRE INVERTERS: UL 1741 CERTIFIED,IEEE 1547,929,519. 5. INVERTER(S) USED IN UNGROUNDED SYSTEM SHALL BE LISTED FOR THIS USE [NEC 690.35(G)]. 6. AS SPECIFIED BY THE AHJ. EQUIPMENT USED IN UNGROUNDED SYSTEMS LABELED ACCORDING TO NEC 690.35(F). 7. ARRAY DC CONDUCTORS ARE SIZED FOR DERATE CURRENT. 8. ALL INVERTERS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS, AND SOURCE CIRCUIT COMBINERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4(D).SHALL BE INSTALLED ACCORDING TO ANY INSTRUCTIONS FROM LISTING OR LABELING NEC 110.3]. JONATHON BEEVER RESIDENCE ROOF HEIGHT:SINGLE STORY JURISDICTION: FL -CITY SANFORD APN:311-931-524-030-000-30 m t 130' l 0 1 8 1624 130' ILLUMINE i LOUR, AIR COROR DOW i ELECMCA1 CONTAACMRS 1537 WEST SMITH STREET ORLANDO, FLORIDA 32804 PHONE 407-422-7657 ELECTRICAL LICENSE: EC0001898 SOLAR LICENSE: CVC56861 PROPERTY LINE CLIENT INFO JONATHON BEEVER RESIDENCE PHOTOVOLTAIC ARRAYS ON ROOF CONDUIT RUN ON ROOF) PVINVERTER MAIN SERVICE PANEL 2445 WASHINGTON COURT, SANFORD,FL 32771 PRN NO: BHR-000354 ENGINEER OF RECORD REVISIONS ID DATE REV COVER PAGE DESIGNER: AHJ CHECKED BY: SK DATE: 07/25/17 SCALE: AS NOTED T- 1 INSTALLATION NOTES: 1. SOLAR PHOTOVOLTAIC SYSTEM TO BE INSTALLED ON RESIDENTIAL STRUCTURE. 2. THIS PROJECT HAS BEEN DESIGNED IN COMPLIANCE WITH THE 2014 FBC TO WITHSTAND A BASIC WIND SPEED OF 110 MPH (3 SECOND GUST), WIND EXPOSURE B. 3. THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL OR BUILDING ROOF VENTS. 4. ALL CONDUCTORS AND CONDUITS MOUNTED ON ROOF SHALL BE MINIMUM 2.5" ABOVE ROOF SURFACE (INCLUDING CABLES UNDERNEATH MODULES AND RACKING). 5. LAG SCREWS SHALL BE AT LEAST 6" FROM ANY NAILING PLATES. 6, LAG LENGTH MUST HAVE A MINIMUM 2.5" THREAD DEPTH INTO THE STRUCTURAL BEAM. 7. ROOF ACCESS POINTS SHALL BE PROVIDED PER THE FOLLOWING (IRC R324.7.1): LOCATED IN AREAS NOT REQUIRING PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS DOORS OR WINDOWS. LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS: TREE LIMBS,WIRES, OR SIGNS. SITE INFORMATION M P-01 AZIMUTH 1w PITCH 22' NO.OF MODULES 1 s ARRAY AREA 264sq.ft WIND SPEED 110 MPH SNOW LOAD 1 0 PSF AERIAL VIEW fir,:-..a M P-01 ALUMINIUM RAILS R SPACING a ILLUMINE i Because qualitymattei a I e° IV, OR -puffff SOUR, AIR CONOMOMMO A EU MICAI CONTRACTORS 1537 WEST SMITH STREET ORLANDO, FLORIDA 32804 PHONE 407-422-7657 ELECTRICAL LICENSE: EC0001898 SOLAR LICENSE: CVC56861 CLIENT INFO JONATHON BEEVER 2445 WASHINGTON COURT,SANFORD,FL 32771 PRN NO: BHR-000354 ENGINEER OF RECORD I REVISIONS I I ID I DATE I REV MOUNTING DETAILS DESIGNER: A,J CHECKED BY: SK DATE: 07/25/17 SCALE: AS NOTED 0 2 4 8 12 I SCALE: 1'-0" M-1 INSTALLATION NOTES: 1. RACKING SYSTEM AND PV ARRAY SHALL BE INSTALLED ACCORDING TO CODE -COMPLIANT INSTALLATION MANUAL. 2. ROOF MOUNTED STANDARD RAIL REQUIRED ONE THERMAL EXPANSION GAP FOR EVERY RUN OF RAIL GREATER THAN 40°. 3. JUNCTION BOX SHALL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. IT SHALL BE FLASHED AND SEALED PER LOCAL REQUIREMENTS. 4. ROOF TOP PENETRATIONS PERTAINING TO SOLAR RACKING WILL BE COMPLETED AND SEALED WITH APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED CONTRACTOR. 5- ALL PV RELATED RACKING ATTACHMENTS WILL BE SPACED NO GREATER THAN THE SPAN DISTANCE SPECIIFIED BY THE RACKING MANUFACTURER O.C. FINAL ATTACHMENTS LOCATION MAY BE ADJUSTED IN THE FIELD AS NECESSARY, 6. ALL PV RELATED RACKING ATTACHMENTS SHALL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS. MODULES: HYUND I SOLAR-HYUNDAI HIS-S290RG MODULE DIMS: 64.57"09.29"x1.38" LAG SCREWS: 5/16" x 3.5": 2.5" M IN EM BEDM ENT NOTE: INSTALLER TO VERIFY RAFTER SIZE, SPACING AND SLOPED SPANS, AND NOTIFY ANY DISCREPANCIES BEFORE PROCEEDING. ROOF I ROOF TYPE I ATTACHMENT ROOF EXPOSURE FRAMETYPE FRAMESIZE RAFTERSPACI MAX.RAILSPANMAX.RAILOVERHANG M P-01 I COMPOSITION SHINGLE I FLASHED L-FOOT ATTIC RAFTER 2X4 1 2'-0" 1 4'-0 2'-0" n^1 An &A^M1 11 r! RAIL i STAINLESS STEEL 5/16" HANGER BOLT 2-1/2" EMBEDMENT PILOT HOLE REQUIRED MODULE Lrriwr rzNL) ULrrn 3) SCALE: NITS uv»a DEAD LOAD CALCULATION BOM QUANTITY I LBS/ UNIT TOTAL VVEIGHT(LBS) MODULES 15 41.20 618.00 MDCLAMP 26 0.05 1.30 ENDCLAMP 8 0.050 0.40 FLASHED L-FOOT 28 1.88 52.71 RAIL LENGTH 101.00 0.68 68.68 SPLICE BAR 6 0.36 2.16 TOTAL WEIGHT OF THE SYSTEM(LBS) 743.3 TOTAL AREA ON ROOF(SQ.FT) 264.27 WEIGHT PER SQ.FT LBS 2.81 WEIGHT PER PENETRATION(LBS) 26.54 ILLUMINE i Because quality matters e° ln7 a°1 l0t+tl1 loU 1fE M SOLAR, ALA CO DMONNO A ELEMCAL COWFA ORS 1537 WEST SMITH STREET ORLANDO, FLORIDA 32804 PHONE 407-422-7657 ELECTRICAL LICENSE: EC0001898 SOLAR LICENSE: CVC56861 CLIENT INFO JONATHON BEEVER 2445 WASHINGTON COURT,SANFORD,FL 32771 PRN NO: BHR-000354 ENGINEER OF RECORD I REVISIONS I I ID I DATE I REV I STRUCTURAL DETAILSI DESIGNER: AJ CHECKED BY: SK DATE: 07/25/17 SCALE: AS NOTED M-2 PV MODULE SPECIFICATIONS PV INVERTER SPECIFICATIONS SYSTEM CHARACTERS71CS MODEL NUMBER M ODULE POWER @ STC Voc(Open Circuit Voltage) Vm p(Max Power Voltage) Isc(Short Circuit Current) Im p(Max Power Current) HYUNDAI HiS S29ORG MODEL NUMBER POWER RATING MAX OUTPUT CURRENT CEC WEIGHTED EFFICIENCY MAX INPUT CURRENT MAX DC VOLTAGE SE5000A-US(24OV) DC SYSTEM SIZE INVERTER FIXED STRING VOLTAGE (Vm p) MAX INVERTER SYSTEM VOLTAGE(Voc) MAX SHORT CIRCUIT CURRENT OPERATING CURRENT 435OW 290 Watts Volts DC Volts DC Amps Amps 5 kWAC Amps Am ps 350.OV 38.8 21 500.0V 32 98.00% 15.OA 9.7 45 Vohs 12.4A 9.1 500 OPTIMIZER CHARACTERISTICS I CONDUIT SCHEDULE M IN INPUT VOLTAGE MAX INPUT VOLTAGE MAX INPUT CURRENT MAX OUTPUT CURRENT 8V TAG ID CONDUIT SIZE CONDUCTOR NEUTRAL GROUND 48V 1 FREE AIR 2) 1OAWG PV WIRE NONE 1) 10AWG BARE COPPER 10A 15A 2 314"EMT OR EQUIV 2) 10AWG THHIWTFRW -2 NONE 1) 10AWG THHWTMNN-2 3 314"EMT ORBCUIV 2) 10AWG THHWTHWN-2 1) 10AWG THHPYTHWN-2 1) BAWG THHN/THMIN 2 THREE LINE DIAGRAM 200A END FEI MAIN BREAKEI ADD 2P 30A 2P PV BREAKER AT OPPOSITE END OF BUS BAR DC WIRE CALCULATIONS ALLOWABLE BACKFEED INVERTER OVERCURRIR(T PROTECTION = INVERTER OUTPUT x CONTINUOUS LOAD x #NO OF INVERTER 21Ax1.25x1 26.3A PV BREAKER = 30A MAIN CIRCUIT BREAKER = 200A MAIN PANEL RATING = 200A 120% X MAIN PANEL RATING -MAIN CIRCUIT BREAKER = 40A TOTAL REQUIRED PV BREAKER SIZE = 30A 40A >= 30A THE DESIGNED INTERCONNECTION MEETS THE 705.12(D)(2) REQUIREMENTS APPROVED BY: HYUNDAI SOLAR HiS-S290RG (15) MODULES OPTIMIZERS WIRED IN (1) SERIES OF (15) OPTIMIZERS SOLAREDGE P300 OPTIMIZER CONDUCTOR SPECIFICATIONS REQUIRED CONDUCTORAMPACRY TERM INAL RATING CHECK CORRECTED AM PACITY CALCULATION DERATED CONDUCTOR AM PACITY CHECK TA G CIRCUIT ORIGIN CIRCUIT TEMP. TRADE AMPACITY RATING@ 30-C Isc #OF MAX CURRENT 125%PER MAX 125% PER MAX CUR14M TERMINAL CONDUIT DERATED TEMP CONDUCTO MAX CURRENT DEBATED ID DESTINATION MATERIAL x (Amp x PARALLEL = PER X 690.8(B)(2)( = CURRBNTPBt PER c RATING@ AMPACITY X X FILL = PER < CONDUCTORRATINGSIZEPER690.8(A)(1) DEBATE R s) STRINGS 690. A)(1) a) 690.8(13)(2)(a) 690.8( B)()() 2 a 60°C DEBATE 690.8(13)(2)(a)AMPACITY310.15(8)(16)AMPACITY 1 PV STRING JUNCTION BOX COPPER 90°C 10 40A 1 x 15 x 1 15.OA 7 1.25 18.8A 18.8A 30A 40A x 0.58 x 1.00 23.2A 18AA 23.2A 2 JUNCTION BOX INVERTER COPPER 90°C 10 40A 1 x 15 x 1 15.OA x 1.25 1 = I 18AA 18.8A I < 30A 1. 40A x 0.71 x 1.00 28.4A 181A 28AA AC WIRE CALCULATIONS TA CONDUCTOR SPECIFICATIONS REQUIRED CONDUCTOR AMPACITY G CIRCUIT ORIGIN CIRCUIT TEMP. TRADE AMPACITY @ INVERTER MAX CURRENT 126% PER MAX ID DESTINATION MATERIAL 30°C PER OUTPUT x NUMBER OF INVERTER = PER X 690.8(B)(2)1 = CURRENT PER RATING SIZE 310.16(B)(16) CURRENT 690.8(A)(3) a) 690.8(B)(2)(a) 3 INVERTER PV BREAKER COPPER 90°C 10 40 21 x 1 = 21.OA x 1 1.26 = 26.3A TERMINAL RATING CHECK CORRECTEDAMPACITY CALCULATION DERATED CONDUCTOR AMPACITY CHECK MAX CURRENT TERMINAL CONDUIT DERATED MAX CURRENT DERATED PER < RATING@ AMPACITY X TEMP X FILL = CONDUCTO PER < CONDUCTOR 690.8(B)(2)(a) 60°C DERATE DERATE R 690.8(S)(2)(a) AMPACITY AMPACITY 26.3A < 30 40 x 1 0.87 1 x 1 = 34.8A 26.3A < 34.8A ILLUMINE i f3ecause quality matters ARMLLM01e° AOLAR SOLAR AM CONDMOMM10 S VJCrMCAI CON AACMRS 1537 WEST SMITH STREET ORLANDO, FLORIDA 32804 PHONE 407-422-7657 ELECTRICAL LICENSE: EC0001898 SOLAR LICENSE: CVC56861 CLIENT INFO JONATHON BEEVER 2445 WASHINGTON COURT,SANFORD,FL 32771 PRN NO: oc,000t fF ENGINEER OF RECORD r REVISIONS ID I DATE I REV I HREE LINE DIAGRAM DESIGNER: AJ CHECKED BY: SK DATE: 07/25/17 SCALE: AS NOTED E-1 A WARNING ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED LABEL LOCATION DC DISCONNECT, INVERTER PER CODE: NEC 690.35(F)] To be used when inverter is ungrounded] r 0 WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT LABEL LOCATION AC DISCONNECT.POINT OF INTERCONNECTION PER CODE: NEC 690.17(E)] A WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION AC DISCONNECTROINT OF INTERCONNECTION PER CODE: NEC 690.17(E)] LABEL LOCATION INVERTER, JUNCTION BOXES(ROOF), AC DISCONNECT PER CODE: NEC 690.13.G.3 & NEC 690.13.G.41 LABEL LOCATION CONDUIT, COMBINER BOX PER CODE: NEC690.31(G)(3)(4) & NEC 690.13(G)(4)] INVERTER 1 LABEL LOCATION DC DISCONNECT PER CODE. NEC 690 14(C)(2)] LABEL LOCATION AC DISCONNECT. POINT OF INTERCONNECTION PER CODE: NEC 690.54] LABEL LOCATION POINT OF INTERCONNECTION PER CODE: NEC 705.12(D)(7) I Not Regwred d Panel board rs rated not less than sum of ampere ratmgs of al: overcunent devu,es supplymg RI CAUTION: SOLAR CIRCUIT LABEL LOCATION MARKINGS PLACED ON ALL INTERIOR AND EXTERIOR DC CONDUIT, RACEWAYS, ENCLOSURES AND CABLE ASSEMBLES AT LEAST EVERY 10 FT, AT TURNS AND ABOVE/BELOW PENETRATIONS AND ALL COMBINER/JUNCTION BOXES. PER CODE IFC605.11.1.4) LABEL LOCATION DISCONNECT, POINT OF INTERCONNECTION PER CODE: NEC690.13(B)] A WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM LABEL LOCATION POINT OF INTERCONNECTION PER CODE: NEC705.12(D)(4)] CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED LABEL LOCATION WEATHER RESISTANT MATERIAL. DURABLE ADHESDIVE, UL969 AS STANDARD TO WEATHER RATING (UL LISTING OF MARKINGS NOT REQUIRED), MIN Y/" LETTER HEIGHT ARIAL OR SIMILAR FONT NON-BOLD,PLACED WITHIN THE MAIN SERVICE DISCONNECT,PLACED ON THE OUTSIDE OF THE COVER WHEN DISCONNECT IS OPERATED WITH THE SERVICE PANEL CLOSED. PWER CODE: NEC690.15 ,690.13(B)) WARNING: POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN 4 1V SOLAR PHOTOVOLTAIC ARRAYS ON ROOF PVINVERTER SERVICE POINT & UTILITY METER 2445 WASHINGTON COURT,SANFORD,FL 32771 ALL PLACARDS SHALL BE OF WEATHER PROOF CONSTRUCTION, BACKGROUND ON ALL PLACARDS SHALL BE RED WITH WHITE LETTERING U.O.N. PLACARD SHALL BE MOUNTED DIRECTLY ON THE EXISTING UTILITY ELECTRICAL SERVICE. FASTENERS APPROVED BY THE LOCAL JURISDICTION ILLUMINE i fic:,fi(:sE yualrtyn atters ON, VL"FflrffflEMELMlRFF SOU), A!) CONDMON1N0 A ELECTRICAL CONMUORS 1537 WEST SMITH STREET ORLANDO, FLORIDA 32804 PHONE 407-422-7657 ELECTRICAL LICENSE: EC0001898 SOLAR LICENSE: CVC56861 CLIENT INFO JONATHON BEEVER 2445 WASHINGTON COURT,SANFORD,FL 32771 PRN NO: BHR-000354 ENGINEER OF RECORD I REVISIONS I I ID I DATE I REV WARNING PLACARDS DESIGNER: AJ CHECKED BY: SK DATE: 07/25/17 SCALE: AS NOTED PL-1 Efficiency tuns SUNNY BOY 5000TL-US22 240Voc 92 a f; i. 907Be f K Ge (V„ - 400 Vl t 861 _.. El. (V„-ASOV) 0.0 0.2 0 A 0.6 0.8 1.0 1 Output P / Rated Pow - er SU-y bay Soo Sunny Boy 6000TL-US 208 V AC ' 40 V AC 208 V AC 240 V AC 5300 W 6300 W 600 V 600 V 175-480V 210-A80V 125 - 500 V 125 - 500 V 125V/150V 125V/150V 30A/15A 30A/15A Accessories t Speedvrte/Webconnect RSA85 mledaca interface DMA85CB-US 10 SWDM-US-10 Fon kd for SB 3000/3800/ 4000/500OTWS-22 FANKIT02.10 Standard feature O Optional feature - Not available Data of nominal conditions Sunny Boy 7000TL-US 208 V AC 240 V AC 7300 W 600 V 245 - A80 V 125 - 500 V 125V/ 150V 30A/18A Sunny Boy 770OTL-US 208 V AC 240 V AC 8000 W 600 V 270 - 4B0 V 125 - 500 V 125V/150V 30A/ 18A 2/2 4550 W 5000 W 5200 W 6000 W 6000 W 7000 W 6650 W 76BO W 4550 VA 5000 VA 5200 VA 6000 VA 6000 VA 7000 VA 6650 VA 7680 VA 208V/• 240V/0 208V/• 240V/0 208V/• 240V/• 208V/• 240V/0 183 - 229 V 211 - 264 V 183 - 229 V 211 - 264 V 183 - 229 V 211 - 264 V 183 - 229 V 211 - 264 V 60 Hz / 59.3 - 60.5 Hz 60 Hz / 59.3 - 60.5 Hz 60 Hz / 59 3 - 60.5 Hz 60 Hz / 59.3 - 60.5 Hz 22 A 25 A 29.2 A 1 32 A 11 1/2 1 1/2 1/2 1/2 A% A% 4% 4% 97.2 % 97 6% 97.0% 97 4 % 96 8 % 96.8% 96.8% 97.3% 965% 97.0% 96.5% 970% 96.5% 96.5% 96.5% 96.5% A90/519/185 (19.3/20.5/7.3) 187/297/190 (7.4/11.7/7.5) 617 / 597 / 266 (24.3 / 23.5 / 10.5) 370/240/280 (14.6/9.4/ 11.0) 24 kg (53 lb) / 3.5 kg (B lb) 27 kg (60 lb) / 3.5 kg (8 lb) 40 °C +60 °C 1-40 °F _ +140 `F) 29 dB(A) < 29 dB(A) < 29 dBIA) < 29 dB(A) I W < 1 W < I W < 1 W Transformerless Transformedess Tronsformerless Transformerless Convection Fan Fan Fan NEMA 3R NEMA 3R NEMA 3R NEMA 3R 0/0 0/0 0/0 0/0 0/0 •/O/O 0/0/0 0/0/0 UL 17A1, UL 1998, UL 1699B, IEEE1547, FCC Part 15 (Class A & B), CAN/CSA C22.2 107.1-1 SB 5000TL-US-22 SB 6000TL-US-22 SB 7000TL-US-22 SB 7700TL-US22 Electrical Characteristics Multi -crystalline Type Nominal output (Pmpp) W 265 270 275 Voltage at Pmax (Vmpp) V 31.3 31.4 31.5 Current at Pmax (Impp) A 8.5 8.6 8.7 Open circuit voltage (Voc) V 37.9 38.0 38.2 Short circuit current (Isc) A 9.1 9.2 9.3 Output tolerance 3/-0 No. of cells & connections PCs 60 in series Cell type 6" Multi -crystalline silicon with PERL technology (Hyundai cell, Made in Korea) Module efficiency 16.2 16.5 16.8 Temperature coefficient of Pmpp i %/K 0.41 -0.41 -0.41 Temperature coefficient of Voc K I 0.32 -0.32 -0.32 Temperature coefficient of Isc I %/K 0.039 0.039 0,039 z All data at STC (Standard Test Cond,tons) Above data may be changed without prior notice Mono -crystalline Type Nominal output (Pmpp) W 280 I 285 Voltage at Pmax (Vmpp) V 31.7 31.8 32.0 Current at Pmax (Impp) A 8.8 8.9 9.1 Open circuit voltage (Voc) V 38.5 38.7 38.8 Short circuit current (Isc) i A 9.4 9.5 9.7 Output tolerance 3/-0 No. of cells & connections I PCs 60 in series Cell type I 6" Mono -crystalline silicon with PERL technology (Hyundai cell, Made in Korea) Module efficiency 17.1 17.4 17.7 Temperature coefficient of Pmpp I %/K 1 0.42 0.42 0,42 Temperature coefficient of Voc K 0.30 0.30 0.30 Temperature coefficient of Isc I K I 0.047 0.047 0.047 7c All data at STC (Standard Test Conditions) Above data may be changed without prior notice Module Diagram Installation Safety Guide unit mm,inch) IN Curves c \ _.. o - ; t,aDrfwim, - r2C X071tI a - fire 75(037 s 1 _ firC BHOLES 1-1 I+) DETAL A t AnO mm I.eemm. t 0937j a9371 ffTTHIU4m CABIE& 4i CABJ COWfOOR CON KrO9 c a io rs x 1s w ss 11 8 c_ W Vakw Orl CROUNDMAM DE74L8.-.-- axe92 talOn•I _. -- taoawAn• swww GROUND HOLE 6e 12 /-1 7 t ww SM(37W)QpWlrrt 2www c 4 = n X IIJJ C 253 @9a Xf1.16 1B 0a a -'- SERION C{ p 9 s r9 is 20 ss n ss u Vokage IV) Only qualified personnel should install or perform maintenance. Be aware of dangerous high DC voltage. Do not damage or scratch the rear surface of the module. Do not handle or install modules when they are wet. Sales & Marketing Hyundai Bldg., 75, Yulgok-ro, Jongno-gu, Seoul 03058, KoreaKfr.WW parr FSC Tel: +82-2-746-4671, 7635, 8556 Fax : +82-2-746-7675 46•C 3 2 40 - 85'C DC 1,000 V (IEC) DC 600 V (UL) 15A I Pointed Date Dec..embe, 201 i 1 A HYUNDAI HEAVY INDUSTRIES RECORD COPY RENEWED FOR CODE COMPL ANCE PLANS EXAMINER 7 DATE SAN 70RD BUILDIN DIVISI(_ry A PERMIT ISSUED SHALL BE CONSTRUED TO BE ALICENSETOPROCEEDWITHTHEWORKANDNOTASAUTHORITYTOVIOLATE, CANCEL, ALTER OR SETASIDEANYOFTHEPROVISIONSOFTHETECHNICALCODES, NOR SHALL ISSUANCE OF A PERMIT PREVENTTHEBUILDINGOFFICIALFROMTHEREAFTERREQUIRINGACORRECTIONOFERRORSINPLANS, CONSTRUCTION OR VIOLATIONS OF THIS CODE 17-2302 0U.DIIVG SANFORD