Loading...
HomeMy WebLinkAbout618 Sarita St; 17-2094; SUNROOMCITY OF SANFORD JULBUILDING & FIRE PREVENTION J1 2017 `l PERMIT APPLICATION Application No: l Documented Construction Value: $ Job Address: ( k ak-,i -n ) Historic District: Yes No, Parcel ID: Residential Commercial Type of Work: New Addition g Alteration Repair Demo Change of Use Move Descri tion of Work: Lt 1 2r X 2-5— (M IM I Y U—,lA Y'! rtAe X i qt4WPlan Review ntact erson: Title: d Phone: { •% p 1 7 Fax: y 0' 73d a Email• s^nlr Cl.c S roperty Owner Information Name t V% h' t.INS Phone: b 7 31) Street: Resident of property? City, State Zip: J e,,,,, [} 3 7 Contractor Information Name 4 i 1 1 t •Y-1 C— Phone: Lt a_ 7 Sc-' 4 9 1-11 6 L Street: 1 Fax: J D City, State Zip: State License No.: c,ig G-Cg s77K o 07 Architect/ Engineer Information Name: L'v=+ '^ V -- --! =1 I b Phone: Street: I / Fax: City, St, Zip: 0 ,, L- 4 :i' E-mail: Bonding Company: Mortgage Lender: Address: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, 19 furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5" Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application I ` 1 I NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental erxtities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: ertify that all of the foregoing information is accurate and that all work will be done i compliance wit Il applicable laws regulating construction and zoning. I 1 17 ignatureofowner gent Date / Signature Contractor/A ent Date MlH Print Owner/Agent' Print C o+fA Na e 7-d -_ 7 Si e o a Date ignature acy-Sta Flo a Date Ry p • BRYAN DORION ...... Notary Public- State of Florida =o"aY°`e BRYAN QORION y , 4: Notary Public• State of FloridaCommission # FF 181319 ? • + - Commission # FF 181319MyComm. Expires Mar 27, 2019 N9F D, My m rOwnerAgflt; BonAr"Ayo%{e f". e or Contractor/Ag ;Qs' S , IIR iakmn e or 3 inn J dir a anal Notary Assn. Produce d' Produce dfi BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing Gas[] Roof Construction Type: Total Sq Ft of Bldg: Occupancy Use: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: Yes No # of Heads k4 APPROVALS: ZONING: —1 - UTILITIES: ENGINEERING: FIRE: COMMENTS: Flood Zone: of Stories: Plumbing - # of Fixtures, Fire Alarm Permit: Yes No WASTE WATER: BUILDING: 'A- I P- Q Ok to construct 12' x 25' (300 S.F.) sunroom as shown on plan. Meets open space requirements, rear yard setback and does not exceed the existing non -conforming side yard setback. Revised: June 30, 2015 Permit Application SCPA Parcel View: 01-20-30-504-0900-0170 http://parceldetai1.scpafl.org/Parcel Detaillnfo.aspx?PI D=O 120305040... Property Record Card r AMERrcel: 01-20-30-504-0900-0170 VPr Owner: MATTHEWS MINDY secc avrv,ri mx Property Address: 618 SARITA ST SANFORD, FL 32773-5037 Parcel Information Value Summary Parcel 01-20-30-504-0900-0170 ner MATTHEWS MINDY Property A ss RD, FL 32773-5037 Mailing 618 SARITA ST SANFORD, FL 32773-5037 Subdivision Name DREAMWOLD Tax Detrict 1 S1-SANFORD DOR Use Code 0 - LY-- Exemptions 00-HOMESTEAD(1994) 2017 Working 2016 Certified Values Values Valuation Method Cost/Market Cost/Market Number of Buildings 1 1 Depreciated Bldg Value 65,282 58,611 Depreciated EXFT Value 6,546 6,546 Land Value (Market) 12,000 12,000 Land Value Ag Just/Market Value *• 83,828 77,157 Portability Adj Save Our Homes Adj 14,071 8,835 Amendment 1 Adj P&G Adj 0 0 Assessed Value 69,757 68,322 Tax Amount without SOH: $733.00 t b - 2016 Tax Bill Amount $640.00 Tax Estimator Save Our Homes Savings: $93.00 Does NOT INCLUDE Non Ad Valorem Assessments Seminole County GIS Legal Description LOT 17 BLK 9 DREAMWOLD PB3PG90 Taxes Taxing Authority Assessment Value Exempt Values Taxable Value County General Fund 69,757 44,757 , 25,000 Schools 69,757 25,000 44,757 City Sanford 69,757 44,757 25,000 SJWM(Saint Johns Water Management) 69,757 44,757 ? 25,000 County Bonds 69,757 44,757 25,000 Sales Description Date Book Page Amount Qualified Vac/Imp WARRANTY DEED 12/1/1990 02251 1953 72,000 Yes Improved WARRANTY DEED 11/1/1987 01909 0522 70,500 Yes Improved WARRANTY DEED 1/1/1977 01 118 0141 3,500 No Vacant omparable Sales I Method Frontage Depth Units Units Price Land Value LOT 0.00 0.00 : 1 $12,000.00 $12,000 Building Information is Bed/Bath count incorrect? Click Here. Fixtures Bed Bath Base Area Total SF Living SF Ext Wall Adj Value Repl Value AppendagesDescription Year Built Actual/Effective c 1 of 2 6/27/2017 4:09 PM REQUIRED INSPECTION SEQUENCE lRpg I -I - 204 -A BUILDING ]PERMIT Min Max Inspection Description Footer / Setback Stemwall Foundation / Form Board Survey Slab / Mono Slab Prepour Lintel / Tie Beam / Fill / Down Cell Sheathing — Walls Sheathing — Roof Roof Dry In Frame Insulation Rough In Firewall Screw Pattern Drywall / Sheetrock Lath Inspection Final Solar Final Firewall Final Roof Final Stucco / Siding Insulation Final Final Utility Building Final Door Final Window Final Screen Room Final Pool Screen Enclosure Final Single Family Residence Final Building (Other) Address: Pd l R QkP—,,-ra IELECT.RICAL ]P.ERMIT Min Mays HnnS ection Descri tionn Electric Underground Footer / Slab Steel Bond Electric Rough T.U.G. Pre -Power Final Electric Final 71l ny}+ j t Minn Marc Ins ection Descri tionn Plumbing Underground Plumbing Sewer Plumbing Tub Set Plumbing Final MECHANICAL;PERMI I Min Mays Inspection Descri tionn Mechanical Rough Mechanical Final Min Mays Gas Unde Gas Roug Gas Final ED) REVISED: June 2014 Page 1 of 1 Permit Number: O a O 3 a 5 y o 9 0 a 0170 GRANT MALOYr SEMINOLE COUNTY Folio/Parcel Identification Nursber: CLERY, OF CIRCUIT COURT & COMPTROLLER Prepared by: ) pY. g944 Fs 1913s (iF35) CLE4,'S t 2017066895 Return to: v_.r I I l / RECORDED 06/30/2017 03c17.' FM a938 RECORDED FEES f1i}.tlU RECORDED BY tsmith NOTICE OF COMMENCEM T State of Florida, County of Orange '? 1 (L q L o +--) `7 The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Description t roperty (legal description of theDropetly, and Street address if available) 2. General description of i ovent - 420 . 190, N4A, l t z..ema cam- e o 3. her. Information 6r e see WpirmaLtkoh if the Lessee contracted for the improvement Interest in Propert. . Name and address of fee simple titleholder (if different from Owner listed above) Name Address 4. Contractor 1 Name rr} "V 1 "'"'' -4 '" ', Tjplep4one Number 5. Surety ( if applicable, a copy of t payment bond is attached) Name Telephone Num Address Amount of Bond 6. Lender Telephone N 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by §713.13(1)(a)7, Florida Statutes. Name Telephone Number Address S. In addition to himself or herself, Owner designates the following to receive a copy of the Lienor's Notice as grovlde I to §?513(1)(b), Florida Statutes. Name IL2/ -}- ` I vN, I _ I TeleDtxQne Number 9. Expiration t% 6f notice of coltnllencefnent (the expiration date may n be before the completion of construction and final paymentlo4hepontractor, but will be 1 year from the date of recording unless a different date is specified) ®_p, [_3_ 1 WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. perjury, I declareit)taad the foregoing notice of commencement and that the are trlq to thtf bk tno edge and belief. Sihefture of Owner or L Sseey6r OwRr'3m6n6ssee's Authorized Officer/Director/Partner/Manager Signatory's Title/Office rrhe foregoing instrument was acknowledged before me thiSCday'A )Y1.by T monthlyearname of pe o as for Ty u rity, e.., , rustee, alto in fact Name f art on behalf of ment was executed b2.1 OA1 ublic - State tea" or sta nam f Notary Public r°, ¢, NotaryPuIr- State:offtfridaCommission # FF 19ersonallyKnownORProducedID `=:My Comm. Expires M2019cedBonded through National Assn. Form Revised: September 26, 2011 Book8944/Page1908 CFN# 2017066895 Page 1 of 1 http://officialrecordsbv.seminoleclerk. org/BrowserView/ 7/24/2017 07/07/2017 07: 59 4073223039 RECORD COW PAGE 01/06 d JUL I i Zav am .10L. Rift an a NALUMINUM SCREEN DESIGN Pi n Types: Asr_ al-7 _27 PooA Scnaen/Cage (Removable Screen - Remove sawn whw wind speed exceeds 75 MPH) Pf%A1 SCreWCage (Non -Removable Scan — Designed to v4stand adual Wind Spe4 rupon REVIEWED FOR CODE COMPLIANCE atio Cover I$F Xher PLANS EXAMINER i DATE Troject Addrm: Tontractor ' Name: PRAGER BUILDERS INC SANFORD BUILDIN DIVISION Address: 2938 STONEWALL PL A PERMIT ISSUED SHALL BE CONSTRUED TO BE ALICENSETOPROCEEDWITHTHEWORKANDNOTAST4:11WNFORD AUTHORITY TO VIOLATE, CANCEL, ALTER OR SETASIDEANYOFTHEPROVISIONSOFTHETECHNICALZipCode:32M CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENTTHEBUILDINGOFFICIALFROMTHEREAFTERPhone1Fa :4a 383- 1 q073 _3p3g REQUIRING A CORRECTION OF ERRORS IN PLANS, CONSTRUCTION OR VIOLATIONS OF THIS CODEEMail_ INFOrC PRAGERSUILDERS.COM ChdoSe One: mauFl Pick Up Fed Ee°`Q _ _ No of Copies For FedEX option got to wvvw_aluminUMSaBendesiarLCom and provide FedEx accoun, #} Tayrnent: check[] CMLdi# Card Q For CreM Gard option go to vvww.a>r - - to „ay by credit rani) ENinea`IN p Wand by: 07/07/2017 07:59 4073223039 P PAGE 02/06 ALUMINUM SCREEN DESIGN jw%jLAi.-r:;rurr. & Consl. uc!ion Engineering Uftimate Wind Speed (mph): Z 10 Exposed Category: C Risk Category: Sc Insulated " Pan Roof Fascia Wall: BlockO Conventional Q Uprights z Top Plate x , Kick Plate Pool Screen/Cage: FlDoane GableLl Mansard Guttero Wall: Block Conventional (1 Beams x U0911% x Purfin -x Car Port Insulated I~asciaQ Beams x Pang Wall: Black Ej Conventional M Past x Patio Cover. Insufa#e [] Pan[] I~asciar] Wall: Block[] Conventional] Beams x Past x 9;ing• [dew: 4" Slab Pier'dfUADvn F ios r x PaVerSET AS DA rn i n, u m. & C o r. s i u c, on ' n ('I Ie I e'. n 9 1 N General Notes & Design Standards Screen Patio Room Enclosure) The following are general design standards. More stringent design standards may be noted on the plans. In the event of a conflict in plans and/or design standard dimensions and/or member sizes, the contractor must utilize the more stringent dimensions and/or member sizes prior to ordering materials, fabrication and/or construction. Design Codes: Florida Building Code 2014 (5t' Edition) Aluminum Design Manual 2010 ASCE 7-10 Design Loads: Pursuant to FBC Chapters 16 & 20 Ultimate Wind: -140 MPH (FBC Table 2002.4) (40 psj) Risk Category: -See attach site specific plan sheet (FBC Table 1604.5) Exposure Category: -See attach site specific plan sheet (FBC 1609.4.3) Additional Load requirements: Structural members supporting screened enclosures are designed for wind in both of two orthogonal directions using the pressures given in Table 2002.4. Each primary member is also designed for a 300 pound load applied vertically downward along any 1 foot of any member, not occurring simultaneously with wind load. In addition to wind pressures, purlins is also be designed for a 200 pound load applied vertically downward along any 1 foot of any member, not occurring simultaneously with wind load. Design Basis: Allowable Stress Design (ASD) =Allowable Strength Design (ASD) divide by safety factor General Requirements: Reproductions of contract drawings by contractor in lieu of preparation of shop drawings signifies acceptance of information shown as correct and obligates himself to any expense, real or implied, arising from their use. A change to the structural drawings due to the acceptance of alternates and/or substitutes is the responsibility of the contractor and must be submitted to the engineer for approval. The general contractor and each subcontractor shall review the approve construction plans in its entirety and verify all existing conditions prior to the start of any work. All inconsistencies shall be reported to the designer and/or structural engineer, if needed. Should contractor construct the premises in a fashion not consistent with the plans prepared by the designer and/or structural engineer, or in any fashion, change the plans and drawing without the review and approval from the designer and/or structural engineer. Then designer and/or structural engineer shall bear no responsibility or liability for the construction of premises and accuracy of the drawings. Foundation and Earthwork: Applicable only when unsuitable soils are encountered. When unsuitable soils are encountered as specified bearing strata, notify owner's representative/engineer. Soil bearing capacity — 2,000 psf Minimum Provide neat excavation for footing and place concrete immediately after excavation and inspection. Pump water from footing excavation if greater than one inch. Compact all fill to 95% ASTM D698 density. Unit soil weight = 105 pcf Internal angle of friction = 30 degrees Coeff. Of friction between footing and soil = 0.5 Michael Thompson, P.E. #47509/CA#30930 4401 Vineland Road., Suite A6, Orlando, FL 32811. (P) 407-734-1470 (F) 407-734-1790 www.aluminumscreendesign.com Structural Aluminum: Conform to latest edition of Florida Building Code and Aluminum Design Manual standard practice for aluminum design. All aluminum shall be 6005-T5 (E= 10,000 ksi; Fy = 35 ksi) with a minimum wall thickness of 0.046" Splicing prohibited without prior approval as to location and type. Burning of holes in aluminum members is prohibited. Any member with burned holes must be replaced. Aluminum Protection: Shall be pursuant FBC 2003.8.4. Aluminum surfaces in contact with dissimilar materials, lime -mortar, concrete, or other masonry materials, shall be protected with powder coated or ESP paint or alkali -resistant coatings, such as heavy -bodied bituminous paint or water -white methacrylate lacquer. Screws: Aluminum self -tapping screws shall conform to ASME B 18.6.4 specification. Self —tapping screws shall meet the requirements of ADM J.5 Maximum fastener spacing shall not exceed (3+20t) where "t" is the member thickness in inches. For roofing and siding connection, use minimum #12 screws for end and side laps spaced at 12" max for side lap and end lap fasteners shall be no more than 2" from the end of overlapping sheets. Bolts: Bolts and other fasteners shall be aluminum, stainless steel, hot -dip or electro-galvanized steel. Double cadmium plated steel bolts may also be used. Bolt holes diameter shall not exceed 1/16" larger than the bolt diameter and shall be spaced at a minimum of 2.5 times the bolt diameter with minimum edge distance of 1.5 times the bolt diameter. Bolts shall meet the requirements of ADM J.3 Chair Rails, Purlins & Wind Brace: Chair rails, purlins and wind brace shall conform with the below maximum span length. If the event contractor's specific site plan conflict with the below recommended length, the contractor shall utilize the more stringent dimensions and member sizes prior to ordering materials, fabrication and/or construction. Wind Speed =140 MPH 2 x 2 Chair Rail = 6'-0" 2 x 2 Purlins = 6'-6" 2 x 2 Wind Brace = 4'-3" 2 x 3 (0.125) Wind Brace = 9'-0" 2 x 3 Chair Rail = 7'-3" 2 x 3 Purlins = 7'-3" 2 x 3 Wind Brace = 8'-9" 2 x 4 Wind Brace = 9'-0" Concrete Conform to ACI 318, latest edition and ACI 301 Compressive Ultimate Strength (Minimum at 28 days) shall be 3000 psi Exposed chamfer edges shall be'/<" Reinforcine Steel: Conform to ACI 318 and 315, Latest edition All reinforcement steel shall be ASTM A615 Grade 60. Smooth dowels & ties shall be ASTM A 18 5 Welded Wire Fabric shall be ASTM A185 or A82 (Flat sheet). Deformed bar anchors shall be ASTM A496, Grade 70 Cover: Footing 3" Washer: Washers shall be used under bolt heads and under nuts. Hole Alignment: Poor matching holes must be rejected. Contractor shall prevent holes from drifting and distort the metal. All chips and foreign matter between contacting surfaces shall be removed before assembly. Michael Thompson, P.E. #47509/CA#30930 4401 Vineland Road., Suite A6, Orlando, FL 32811. (P) 407-734-1470 (F) 407-734-1790 www.aluminumscreendesign.com E5R;ASn" D) i n i ff, c o n K j f uc- n q i - e r': I: Beams & Uprights: In the event of a conflict with the values in this table and the site specific plan, the contractor must utilize the more stringent dimensions and/or member sizes between the site specific plan and the below applicable span limitations prior to ordering materials, fabrication and/or construction. 140 MPH PRIMARY BEAMS & COLUMNS -SCREEN PATIO ROOM ENCLOSURES ROOF PANELS Beam -Size Max Beam Span & Max Column Spacing Column -Size Max Column- Height Pan Roof Span Insulated Roof Span 2 X 3 6'-0" 2 X 3 7'-6" 3" Spans 12'-5" 3" Spans 13'-10" 6" Spans 18'-5" 2 X 4 8'-0" 2 X 4 8'-0" 2 X 5 9'-6" 2 X 5 8'-6" 2 X 6 10'-6" 2 X 6 10'-0" Knee Bracing: Contractor shall provide knee bracing on 45 degree angle pursuant the attach detail sheet that specified size and length requirements. Knee bracing on upright above super gutter intersection shall be connected to upright no more than 6" above the super gutter. Knee brace size shall be a minimum of 2 x 2 for beam span of 15' max; 2 x 3 for 30' max; 2 x 4 for beam span greater than 30'. Purlin• Contractor is required to install purlins spaced to align with column spacing; however, spacing between purlins shall not exceed 7'-2". Intermediate/Header Beam: Contractor is required to install a minimum 2 x 7 intermediate header beam supported with 3 x 3 column spaced at 10 feet (max) when insulated roof span exceeds 15 feet. Patio Cover: Contractor is required to install insulated roof covering pursuant to the Florida product approval specification. Overhang shall be a maximum of F-0" along the side, 3'-0" along the front and 1/2" along the front interface between the super gutter and the attached pool cage knee riser wall. Edge Distance: Contractor is required to install uprights to provide a 2" minimum clearance from edge of slab and/or footer. Michael Thompson, P.E. #47509/CA#30930 4401 Vineland Road., Suite A6, Orlando, FL 32811. (P) 407-734-1470 (F) 407-734-1790 www.aluminumscreendesign.com m Nt wD an ral m mm mN CVm N m 0) LLl ti m CDCV r- N m m f CDT. z-k 3 Y 7 2+ ki E. CD c N U3 O N Co e F in tho event of a eondici in member Was shown on the plans and the general notes, the contractor must utilize the more stringent member size requirements. 07/07/2017 07:59 4073223039 P PAGE 06 06 PLAT OF SURVEY for MINDY MATTHEWS Lecja4 -Description t 17, Block .cs, DREA01WUL0, acel•_L'dirl() to the plat thereof as recorded in plat •Book Page' 9J, of t(he PLLI, _ F'IecoT4F, of 5err,inolc County, Florida_ . SRbK £ cnv to;382 (op IRaH tAP *'3'.BT 17 tc, Tot 000E at U 34 44, u v it 20 14 tb jj', 0, Iry lL tir 4L ij • l0 S4iti'Ut YiT. zw 4' LIL RIES. 4 c.L_E cc, C . mliE _ Q l 2oq. tRAMiCAP 338Z 4. 1JAu4 . , .. _, . . Ok to construct 12' x 25' (300 S.F.) sunroom as shown on plan. Meets open space requirements, rear yard setback and does not exceed the existing non -conforming side yard A T7 i- setback. ray.= Y "•,OTir~. 07/07/2017 07:59 4073223039 P PAGE 03106 PRAGER BUILDERS, ENC. 5450 Bryant Avenue - Sanford, FL 32773 p Telephone: (407) 324-9960 - Fax: (407) 322.-3039 State Certified: #CRC053007 www.sunroolmpro.com NAME—& %- 4"l r F # k DIRECTIONS - SCREEN: I CATEGORY_ FLAT: GABLE: TIE IN: F.4Lq, f V1T`4G ROOF SIZE: tq V tP o TYPE: 9 /f pf"--61v -- - - - KiCKPLATE: OUTTSRS' mat wINPOW'PXPi;; C V} y G , i I'RtAMF COI-09: PORCH OVERIIP,NG: HOUSE O'H'; SOFFIT? PEAK: v smE• FAN BFIAMS' + n C Y j- SLAB SIZE: EXISTING SLAB! DEMO: \ N-^ A'k— r le-.Ie; W 1-A Y o ELECTRICAL CiATE CODE: www@ s o(ompro s comJam' MATERIALAND WORKWANSHM GUARANTEED FOR 2 YEARS, n+rruts NOTE: I) HAIRLINE CRACKING OF NEW CONCRETE SLABS IS A Contactor enpressly reserves ell contractors, mechenles and materiq COMMON OCCURRENCE, Man's lien wbiob maybe asserted anda any pr—loom of the law to 2) SPRIN[KLER SYSTEM MUST BE RELOCATED BY CUSTOMEF- secure payment of the contract price and may nsscl and fix the same as a 3) DRANAOX AS 13ASP- OF ROOM IS RESPONSIBR ITY OF lien upon the real property on which installation is made. HOMEOWNER purchaser agrees to supply electrical power at Job site, 4) FLOOR MAY REQUIRE LEVELING PDX TXI,E XNSTAI.LAT'ION, 5) OWM IS RESPONSIBLE FOR ANY REINSPECTION FEES DUE TO INACCESSIBILITY OR MISSING PERMIT. 6) HOMEOWNER IS RESPONSIBLE FOR U0A. ORARC AITWVA) . 7) ALL WORK AREAS MUST aE Fib OF) lEBRIS AND Email- • f(JJ FURNITURE. ! I,We-have re c foTgoin ropos con cept the same on the terms arld coadi ors prinked on tits tc+•crse side r, o 7 'J as stated abov `( I orrrwtcl rRz Purrltas r:?t' . 0 6 Estimator_ 11 Terms: V aAl-DUE Cash. Check. 3% Com b)'oeee ee for Credit Card transactions ye s la.bor and'rtjateri;l Lnrsratstx. /, i a_ //. BEAM IS ATTACHED TO UPRIGHTS WITH (8) #10 1" ON EACH SIDE OF BEAM w C7 U oN, V 3X3 & 2X3 X UPRIGHTS 00 Q a X Q NLu 6" INSULATED PANELS ARE ATTACHI TO ALUMINUM STRUCTURE WITH 4) #10 7" PER PANEL OR 6" FROM ENDS 24" O.C. TYP. 2X3 GIRTS ARE ATTACHED WITH INTERNAL CLIPS WITH (4) 910 1", CAPRI CLIPPED WITH (8) #10 1", OR BLIND SCREWED WITH (3) # 10 2" 2X4 OR GREATER BEAMS UP TO 15' ARE STITCHED TOGETHER WITH #10 1" 6" FROM ENDS 24" O.C. 1X3 BOTTOM PLATE IS ATTACHED TO CONCRETE WITH 2-114" X 114" TAPCONS (5" X 1/4" IF THRU PAVERS) 6" FROM ENDS 24" O.C. 2 X 2 X 1/8" ANGLE SCREWED INTO EACH SIDE OF BEAM WITH (2) 10 1" & INTO CONCRETE WITH (1) 2-1/4" X 1/4" TAPCON FRONT WALL, BACK WALL & SIDE WALLS TOP PLATES ATTACH TO ROOF MEMBERS WITH # 10 1" 6" FROM ENDS 24" O.C. TRAP 24" O.C. MAX 4" FROM EWED THROUGH GUTTER INTO ATTACHED TO FRONT OF XTRUDED GUTTER IS ATTACHED TO ASCIA WITH # 10 4" 6" FROM ENDS 4" O.C. INTO RAFTER TAILS KNEE WALL ATTACHES TO STRUCTURAL GUTTER WITH 4" 2 X 2 X 1/8" ANGLE & (4) #10 1" INTO GUTTER & BEAM PER SIDE 2X2 POST .046 OR GREATER 2 HINGE HINGE LOCATIONS SCREEN DOOR FULL Z OR DOOR JAM STANDARD DETAIL EACH DOOR IS SCREWED INTO UPRIGHTS WITH #10 1" 6" FROM ENDS 24" O.C. ALUMINUMSCREENDESIGN.COM DESIGN STATEMENT MICHAEL THOMPSON ALUMINUMSCREENDESIGN ALL TAPCONS SHALL PROVIDE MINIMUM OFRI , ALLOY IS 6005-T5 1/8" EMBEDMENT DEPTH 4401 VINELAND ROAD @YAHOO. COM THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE TO MEET THE REQUIREMENTS OF THE 2014 (5TH EDITION) SUITE A6 OF THE FLORIDA BUILDING CODE FOR OPEN AND SEMI -OPEN STRUCTURES AND SHALL WITH STAND ULTIMATE WIND ORLANDO, FL 32811 PHONE: 407-734-1470 SPEEDS OF 140 MPH (FOR 3 SECOND GUSTS) NOMINAL SPEED109.2 MPH UP TO A 15FT ROOF HEIGHT, FACTOR OF 1.0, AND EXPOSURE C, RISK CATEGORY II. # 47509 FAX: 407-734-1790 CONTRACTOR SHALL FIELD VERIFY ALL PLANS DIMENSIONS PRIOR TO MATERIAL PURCHASE, FABRICATION AND CONSTRUCTION CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY SHOULD SITE CONDITIONS DIFFER FROM CONSTRUCTION PLANS 'eA#3 093 0 2X3 SIDE WALL DETAIL6" INSULATED PANELS ARE ATT TO ALUMINUM STRUCTURE WITHCHED 4) #10 T' PER PANEL OR 6" FROM ENDS 24" O.C. TYP. 2X3 BEAM 1X3 BOTTOM PLATE IS ATTACHED TO UPRIGHTS WITH CAPRI CLIP WITH (4) 10 1" OR BLIND SCREWED WITH (2) GUTTER & FASCIA DETAIL EXTRUDED FASCIA IS ATTACHED TO 6" INSULATED ROOF WITH 910 1" 6" FROM ENDS 24" O.C. EXTRUDED GUTTER IS ATTACHED TO 6" INSULATED ROOF WITH 910 1" 6" FROM ENDS 24" O.C. 2X2 POST .046 OR GREATER 2 HINGE HINGE LOCATIONS SCREEN DOOR FULL Z OR DOOR JAM STANDARD DETAIL EACH DOOR IS SCREWED INTO UPRIGHTS WITH #10 1" 6" FROM ENDS 24" O.C. ALUMINUMSCREENDESIGN.COM DESIGN STATEMENT MICHAEL THOMPSON TAL IS.046 OR GREATER,IS 6005-T5ALUMINUMSCREENDESIGNALLTAPCONSSHALLPROVIDEMINIMUMOF118EOMBEDMENT DEPTH 4401 VINELAND ROAD @YAHOO.COM THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE TO MEET THE REQUIREMENTS OF THE 2014 (5TH EDITION) SUITE A6 OF THE FLORIDA BUILDING CODE FOR OPEN AND SEMI -OPEN STRUCTURES AND SHALL WITH STAND ULTIMATE WIND ORLANDO, FL 32811PHONE: 407-734-1470 SPEEDS OF 140 MPH (FOR 3 SECOND GUSTS) NOMINAL SPEED109.2 MPH UP TO A 15FT ROOF HEIGHT, FACTOR OF 1.0, AND EXPOSURE C, RISK CATEGORY II. E. # 475 09 FAX: 407-734-1790 CONTRACTORO ONTRACCTOR SHALL NO FY T E ENGINEER IVERIFYALLPLANS ,IMENSIONS MMDIA ELY SHOD PRIOR TO DMATERIALSITE ONDI IONS DIFFER FROM ONSTRUCPURCHASE, FABRICATION AND OT ON r ANSON CA#3 0930 ATTACHMENT DETAIL CUSTOM WINDOW ALUMINUM FRAME WINDOW 10 2" 6" FROM ENDS O 24" O.C. ON ALL SIDES TO ALUMINUM FRAME B # 10 1" THRU FACE 6" FROM ENDSO24" O.C. ON ALL SIDES TO ALUMINUM FRAME 2X2 POST .046 OR GREATER HINGE LOCATIONS DOOR FULL Z OR DOOR JAM STANDARD DETAIL 2 HINGE DOO EACH DOOR IS SCREWED INTO UPRIGHTS WITH #10 1" 6" FROM ENDS 24" O.C. ALUMINUMSCREENDESIGN.COM DESIGN STATEMENT MICHAEL THOMPSON IS 6005-T5ALUMMUMSCREENDESIGNALLTAPCONSSHALLRODEMINIMUMOFR118EOMBEDMENT DEPTH 4401 VINELAND ROAD SUITE A6@YAHOO. COM THIS STRUCTURE HAS BEEN DESIGNED IN OF THE FLORIDA BUILDING ODE FOR OPEN AND ACCORDANCE EMI-OPEN STRUCTURES ANDS AELLTWITH STAND ULTIMATES OF THE 2014 (5TH WINDORLANDO ' FL 32811 PHONE: 407-734-1470 SPEEDS OF 140 MPH (FOR 3 SECOND GUSTS) NOMINAL SPEED109.2 MPH UP TO A 15FT ROOF HEIGHT, FACTOR OF 1.0, AND EXPOSURE C, RISK CATEGORY IL E # 47509 FAX: 407-734-1790 CONTRACTOR OCONTRACTOR ORSHALL NOTVERIFY E ENGINEER MMEDIAOTELY NS SHOD D R TO SITE CONDI IONS DIFFEAL PURCHASE, RFROM ROM CONSTRURICATION AND CTION PLANSON A#30930 I idd &u In,, Code Online https://www.rioriclai)uumng.org/pr/pr_app_isi.asp a ,. 1 i YA.TdF M BCIS Home Log In User Registration Hot Topics Product Approval USER: Public User r rt . ::: Submit Surcharge . Stats & Facts Publications FBC Sti Product Approval -Meng > Product_or Application Search > Application List Search Criteria Code Version 2014 FL# Application Type ALL Product Manufacturer Category ALL Subcategory Application Status ALL Compliance Method Quality Assurance Entity ALL Quality Assurance Entity Contract Expired Product Model, Number or Name ALL Product Description Approved for use in HVHZ ALL Approved for use outside HVHZ Impact Resistant ALL Design Pressure Other ALL Search Results -Applications_ FL# ` Tyae r Manufacturer V; FL2291-R9i Revision Four Seasons Building Products ' Tri History Category: Roofing (9 i Subcategory: Products Introduced as a Result of New Technology Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commisf on if necessary. Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-182 The State of Florida is an AA/EEO employer. Coovrioht 2007-2013 State of Florida.:: Privacy Statement :: A ccessib Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, pleas Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide they have one. The emails provided may be used for official communication with the licensee. However email addresses supply a personal address, please provide the Department with an email address which can be made available to the public Chapter 455, F.S., please click here . Product Approval Accepts: eCfxck - Credit Cara Safe 7/6/17, 11:58 AN 2 EPS FOAM CORE ROOF PANELS SEAL JOINT WITH CONTINUOUS CAULKING OR SEALING TAPE OPTIONAL FAN BEAM I Uj w:.:•:.:: I 2 PANEL INTERLOCK VERT SECTION PROVIDE 1Y/2" MIN. SPACING BETWEEN TO WOOD_ (2) 1/4" 0 LAG SCREWS WITH ANCHORS IN EACH j 1%2" MIN. THREAD PENETRATION TO PAIR, TYP. EXISTING WOOD HOST (G=0.55 OR EXISTINGBETTER), 3/4" ,1IN. EDGE DISTANCE, SPACED AT 6" O.C. MAX. HOST STRUCTURE 1 BY OTHERS, TYP. j TO CONCRETE: (2) 1/4" 0 ITW STAINLESS MIN. PANEL i STEEL TAPCONS with 13/4" MIN. EMBED. FDEPTH TO EXISTING 3192PSI NON -CRACKED CONCRETE HOST, 2%2" MIN. EDGE 0 DISTANCE, SPACED AT 12" O.C. MAX. 0 0 0 0 4' MAX WIDTH PER INTERLOCKING PANEL 1/4" PER FOOT MIN SLOPE) EPS CORE (1.0 PCF) 0.024" OR 0.030" ALUM OR 269a - STEEL TOP & BOTTOM FACINGS HOLLOW BLOCK: (2) t/4" O ITW I j `C-CHANNEL, MIN 0.045" e STAINLESS STEEL TAPCONS WITH 1 %4" THICK (6063-T6 ALUM) e MIN. EMBED. TO EXISTING HOLLOW --CLEAR SPAN (L) INSIDE TO INSIDE -1 1 OVA BLOCK, 2Y2" MIN. EDGE DISTANCE,—#8x9/6" SAE GRADE 5 SMS AT 6" SPACED AT 6" O.C. MAX. 36" O.C. MIN. TOP & BOTTOM, TYP. i 1 21 1 ROOF PANEL/SPAN DETAIL WII: 12" MAXIMUM ALLOWABLE CLEAR SPAN TABLE 1 N.T.S. VERT SECTION ROOFS OVER SCREEN WALLS AND PATIO COVERS: Wind S P Expo' Live Load sure 8/or Uplift Deflection Limit L/ ) 0.024" plum Skin 1-LB EPS 3" Panels 0.030" 26GA 0.024" (") Alum Skin j Steel Skin plum Skin 1-LB EPS ! 1-LB EPS 1.5-LB EPS 4" Panels 0.024" 0.030" Alum Skin ' Alum Skin 1-LB EPS i 1-LB EPS 26ga Steel Skin 1-LB EPS 0.024" Alum Skin 1-LB EPS 6" Panels 0.030" Alum Skin 1-LB EPS 269a Steel Skin i 1-LB EPS 110 MPH 8 I 9 PSF 120 15'-11" 18'-6" 19'-8" 16-8" 18'-11" 20'-5" 23'-T 23'-0" 23'-0" 23'-0" 110 MPH C I 10 PSF 120 16-2" 17'-7" 18'-8" 15'-101' 1T-11" ! 19'4" 27-2" 27-8" 23'.0" 23'-0" 110 MPH 0 13 PSF 120 14'-1" 164" I 17'4" 14'-B" 16'-8" 1T-11" 20'-6" 21'-1" 22'-7' : 23'-0" 120 MPH B I 11 PSF 120 14'-11" 1T4" 18'-6" 16-7" 17'-9" I 19'-1" 21'-10" 27-5" 23'-0" 23'-0" 120 MPH C 12 PSF 120 14'-3" 16'-6" 17-7" 14'-10" 16'-10" 18'-2" 20'-9" 214-4" 22'-5" 23'-0" 120 MPH D i 15 PSF 120 13'-4" 15'-5" I 16-5" IT-11" 16-9" 1 1T-0" 19'-2" 19'-17' 21'-0" 23'-0" i30 MPH B 12 PSF 120 14%2" 16-5" i 17'-6" 14'-10" 16-9" 18'-1" 20'-8" 21'-3" 22'-4" 30 MPH C 14 PSF 120 1T-6' 15'-8" 16-8" 14'-1" 16-12" 17'-3" 19'-6" 20'-2" 21'-3" 23'-0" 130 MPH D 17 PSF 120 12'-7" 14'-7" 15'-6" 1T-2" 14'-11" 16-1" 1T-7" 18'-10" 19'-10" 22'-5" 140 MPH B 14 PSF 120 13'-6" 15'-8" 16'-8" 14'-1" 16'-0" 1 1T-3" 19'-7" 20'-3" 21'-4" 23'-0" 140 MPH C 17 PSF 120 12'-9" 14'-9" 15'-9" 13'-4" 15'-1" 1 16'-3" 1T-11" IVA" 20'-1" 27-9" 140 MPH 0 20 PSF 120 11'-12" IT-11" 14'-5" 17-6" 14'-3" 1 15'-4" 16'-5" 1T-12" 18'-11" 20'-10" 150 MPH B 15 PSF : 120 13'-2" 15'-3" 16'-3" 13'-9" 1F-T' i 16-10" 18'-10" 19-8" 2U-9" 23'-0" 150 MPH C I 19 PSF 120 12'-3" 14'-2" 14'-11" 12'-9" 14'-0" 15'-8" 16' 11" 18'•4" 19'-4" 21'-6" 150 MPH D 23 PSF 120 11' 6" 13'-4" 13'-7" j 17-0" 13'-7" i 14'-8" 15-4" 17-1" 18'-2" 19-6" 156 MPH B 17 PSF 120 12'-8" 14'-8" I 15'-B" 1Y-3" 154' 16'-2" 1T•9" 18'-12" 19'-1T' 22'-7" 156 MPH C 21 PSF 120 11'-11" IT-10" 14' 4" 12'-5" 14' 1" 16-3" 17'-10" 18'-10" 20'-T' 156 MPH 0 25 PSF 120 11' 2" 12-12" 1 13' 0" 11'-8" 13'-3" 1 14'-4" 14'-9" 16'-T 1T-8" 18'-9" 160 MPH B 18 PSF 120 12'-4" 14'-4" 15'-2" 12'-11" 14'-8" 15'-IU' 1T-2" 18'-7" 19-6" 21'-10" 160 MPH C 22 PSF 120 1T-9" 13'-7" j 13'-12" 17-3" 13'-11" 14'-12" 15'-10" 1T-T' 18'-6" 29-1" 160 MPH D 26 PSF 120 10'-12" IZ-9' I 12'-8" 11'-6" 13'-0" 14'-1" 14'-5" 15'-12" 17-3" 18'-3" 165 MPH B i 19 PSF 120 12'-2" 14'-1" 14'-9" 12'-9" 14'-5" 1 164" 16-9" 18'_3" 19'-2" 21'-3" 165 MPH C i 23 PSF 120 11'-6" 13'-4" 13'-T' 17-0" 13'-7" 14'-6" 15'-4" 1T-1" 18'-2" 19'-6" 165 MPH C 28 PSF 120 10'-9" 12'-6" 174" 11'-3" 17-9" 13'-9" 13'-11" 16-6" 16'-9" 1T-9" 170 MPH B i 20 PSF 120 11'-12" 13'-11" I 14'-5" 12'-6" 14'-Z' 15'-4" 16'-4" 17'-12" 18'-11" 20'-9" 170 MPH C 24 PSF 120 11'-3" 13' 1" 13'-2" 11'-9" 13'-4" 14'-5" 14'-11" 16'-7" 1T-9" 18'•12" 170 MPH D 1 29 PSF 120 10'-T' IZ-2" 11'-11" 11'-1" 17-6" i 13'-6" 13'-7" 15'-1" 16'-3" 17'-3" 170 MPH t C 1 30 PSF 80 11'-2" 11'-11" ' 11'-9" 12'-0" 12'-0" j 12'-0" 12-0" 17-0" IZ_0" 12'-0" 170 MPH C 30 PSF' 120 10-5" 11'-11" ( 11'-9" 10'-11" 17-4" j 13'-4" IT-4- 14'-9" 16-11" 16-11" 170 MPH T C 30 PSF' 180 9'-1" 10'-7" 11'-3" T-6" 10'-10" 1 11'4" 13'-4" 13'-8" 14'-5" 16'-9" 175 M H t C i 30 PSF ' 80 11'-2" 11'-11" 11'.9" 12'-0" 12'-0" j 17-0" 17-0" 17-0" 12'-0" 12'-0" 175 MPH C i 30 PSF' 120 10'-5" 11'-11" I 11'-9" 10'-11" 17-4" 13'-4" 13'-4" 14'-9" 16-11" 16'-11" 175 MPH t C 130 PSF' 180 T-1" 10'-7" 11'-3" 9'-6" 10'-IT j 11' 8" 134" 1T-8" 14' 5" 16'-9" 175— MPH t D 31 PSF 80 11' 1" 11'-10" 11'-8" IZ-0" 12'-0" ; 12'.0" 12'-0" 17-0" 12'-0" 12'-0- MPH 0 3" PSF 120 10'-5" 11'-10" 11'-8" 10'-10" 17-4" 1 IT-3" 1S-z' 14'•8" 15'-10" 16-9" TA 1. 5 MAXIMUM ALLOWABLE CLEAR SPAN TABLE ROOFS OVER ENCLOSED SUNROOM ADDITIONS: a® 3 4 5 Wind Speed Expo sure Live Load or Uplift Deflection Limit U... ) 3" Panels 0.024" 0.030" 26ga Steel, 0.024" (') Alum Skin Alum Skin : Skin Alum Skin 1-LB EPS 1-LB EPS : 1-LB EPS 1.5-LB EPS 0.024" Alum Skin 1-LB EPS 4" Panels 0.030" 26ga Steel Alum Skin Skin 1-LB EPS i 1-LB EPS 0.024" Alum Skin 1-LB EPS 6 _Panels 0.030" Alum Skin 1-LB EPS 26ga Steel Skin 1-LB EPS 100 MPH B 13 PSF 120 13'-11" ! 16'-2" 17'-2" 14'-7' 16'-6" 1T-i0" 20'4" 20'-11" 21'-12" 23'-0" 100 MPH B 13 PSF 180 12'-2" 14'-1" 15'-0" 12'-91, 1 14'-5" 15' 7" 17'-9" 18'-3" 19' 2" 22'-4" 100 MPH , B 13 PSF 240 11'-1" 12'-10" 13'-8" 11'-7" i3'-1" 14'-2"' 16'-2" 16'-7" 17'-5" 20'-4" 100 MPH C 16 PSF 120 13'-1" 15'-2" 16'-2" 13'-8" 15'-6" 16'-9" 18'-8" 19'-7" 20'-7" 23'-0" 100 MPH C 16 PSF 180 11'-5" 1X-3" 14'-1" 11'-11" 13'-6" 14'-7" 16'-8" 17'-1" 18'-0" 20'-12" 100 MPH C 16 PSF 240 10' 4" 12'-1" 12'-10" 10'-10" 12'-4" 13'-3" 15'-2" 1 15'-T' 164" 19'-1" 100 MPH D 19 PSF 120 12'-3" I 14'-3" 14'-11" 12'-10" 14' 6" 15'-8" 16'-11" 18'-4" 19'-4" 21'-6" 10 MPH D 19 PSF 180 10' 8" j 12' 5" 13' 3" 11'-2" 12'-8" 13'-8" 15'-8" 16--1.. 16'-11" 19' 8" 100 MPH D 19 PSF 240 9'-9" 11'-3" 12'-0" 10'-2" 11'-6" 12'-5" T 14'-2" f 14'-7" 15' 4" 1 T-10" 110 MPH B 16 PSF 120 IT-1" j 15'-2" 16'-2" IT-8" 15'-6" 16'-8" 18'-7" 19'-7" 20' 7" 23' 0" 110 MPH B 16 PSF 180 11'-5" 13'-3" 14'-1" 11'-11" 13'-6" 14'-7" 16'4" 17'-1" 17'-12" 20'-12" 110 MPH B 16 PSF 240 10'-4" 12'-0" 12'-10" 10'-10" 12'-3" 13'-3" 15'-2" 15'-6" 16'-4" 19'-1" 110 MPH C 19 PSF 120 12'-3" 14'-3" 14'-11" 12'-10" 14'-6" 15'-8" 16' 11" 18'-4" 19'-4" 21'-6" 110 MPH C 19 PSF 180 10'-8" j 1Z-5" 13'-3" 11'-2" 12'-8" 13'-8" 15'-8" IT-1" 16'-11" 19'-8" 110 MPH C 19 PSF 240 9'-9" ; 11'-3" 12'-0" 10'-2" 11' 6" 12'-5" 14'-3" 14' 7" 15' 4" 17 1 1 110 MPH D 23 PSF 120 11'-6" 13'-4" 13'_6" 11'-12" 13'-7" 14'-8" 15' 4" 1T-1" 18'-1" 19'-6" I 110 MPH D 23 PSF 180 10' 0" 11'-8" 12'-5" 10'-6" 11'-11" 12'-10" 14'-8" 15' 0" 15'-101, 18'-5" 110 MPH D 23 PSF 240 9'-1" 10'-7" 11'.3" 9'-6" 10'-10" 11'-8" 13'-4" 13' 8" 14'-5' 16' 9" 120 MPH B 19 PSF 120 12' 4" i 14'-4" 15--1" 12'-11" 14'-7" 15' 9" I 17'-1" 18'-6" 19'-5" 21'-8" 120 MPH B 19 PSF 180 10'-9" 12'-6" 13'-4" 11'-3" 12'-9" 13'-9" 15'-9" 16'-2" 16-12" 19'-10" 120 MPH B 19 PSF 240 9'-9" I 11'-4" 12'-1" 10'-3" 1 V-7" 12'-6"99 14' 4" 14'-8" 15' S" 1 T-12" 120 MPH C 22 PSF 120 1 V-7" I 13'-5" 13'-8" 12'-1" 13'-9" 14'-9" I 15'-6" 17'-3" 18'-3" 19'-9" 120 MPH C 22 PSF 180 10'-1" j T- 2" i 11'- 9" 10'- 8" 12'- 6" 11' 4" 10' 7" 9'- 7" 11'- 12" 10'- 11" 12'- 11" 11'- 9" 14'- 9" 1 T-5" 15'- 2" 13'- 9" 15'- 11" 14'- 6" 18' 7" 16'- j 1_ 120MPHC22PSF240120 MPH D 27 PSF 120 10'-10" 12'-7" 12'75" 11'-4" 12'-10" IT-10" 14'-1" 15'-8" 16-11" 17'-1 V 120 MPH D 27 PSF 180 9'-6" 10'-12" 11'-8" 11'-3" 12'-1" j 13'-10" 14'-2" 14' 11" 17' 5" 120 MPH D 27 PSF 240 8'-7" ! 9'-12" 10'-8" 8'-1Z" 10'-2" 10'-12" 12'-7" 12'-11" 13'-7" 15'-10" 130 MPH 8 22 PSF 120 11'-8" 13'-7" 13'-11" 12'-2" 13'-10" 14'-11" 15'-9" 17-6" 18'-5" 20'-0" 130 MPH B 22 PSF 180 10'-2" 1 V-10" 12'-7" 10'-8" 12'-1" 13' 1" 14'-11" 15'-4" I 16-1" 18'-9" 130 MPH B 22 PSF 240 9'-3" 10'-9" 11'-5" 9'-8" 10'-12" 11'-10" 13'-7" 13'-11" 14' 8" 1T 1" 130 MPH C 26 PSF 120 10'-12" 12'-9" 12'-8" 11'-5" 12'-12" 14'-0" I 14'4" 15'-11" 17'-2" 18'-2" 130 MPH C 26 PSF 180 ! 9'-7" ! 11'-1" 11'-10" 10'-0" 11' 4" 12'-3" j 13'-12" 14'4" 15'-1" 17'-7" 130 MPH C 26 PSF 240 8'-8" 10'-1" 10.9" 9'-1" 10'-4" 11'-1" 12'-9" 13'-1" 13'-9" 15'-12" 130 MPH D 32 PSF 120 10'-3" 11' 7" 11'-51, 10'-9" 12'-V 13,-0" 12'-12" 14' 5" 130 MPH D 32 PSF 180 8'-12" 10'-5" 11' 1" 9' S" 10' 8" 1 V-6" 12-12" 13'-5" 14'-2" 16'-6" 130 MPH D 32 PSF 240 8'-2" 9' 6" 10'-1" 8'-6" 9'-8" 10'-5" 11'-11" 12'-3" 12'-10" 14'-12" 140 MPH 8 25 PSF 120 11'-2" 12'-11" 12'-11" 11'-8" 13'-2" 14'-3" 14'-8" 16.3" 17'-7" 18' 7" ' 140 MPH B 25 PSF 180 9'-9" 1 V-3" 12'-0" 10'-2" 11'-6" 12'-5" 14'-2" 14'-7" 15'-4" 17.-10" 140 MPH B 25 PSF 240 8'-10" 10'-3" 10'-11" 9'-3" 10' 6" 11'-3" i 12--11" i 13'-3" 13'-11:' 16' 3" 140 MPH C 30 PSF 120 10'-5" j 11'-11" 11'-9" 10'-11" 12'-5" 13'4" 13'-4" 14'-9" 15'-12" 16'-1 V 140 MPH C 30 PSF : 180 9'-1" 10'-7" 11'-3" 9'-6" 10'-10" 11'-8" 13' 4" 131-8" 14'-5" 16' 9" 140 MPH C 30 PSF 240 8'-3" j 9' 7" 10'-3" 8'-8" 9'-10" 10'-7" 12'-1" 12'-5" 13%1" 15' 3" 140 MPH D 37 PSF 120 9'-9" ! 10'-10" 10'-8" 10'-3" 11'-3" 12' 1" 12'-1" 13'-5" 14'-6" 15' 4" 140 MPH D 37 PSF 180 8'-7" ! 9'-11" 10'-7" 8'-11" 10'-2" 10'-11" 12'-1" 12'-10" 13'-6" 5' 4" 140 MPH D 37 PSF 240 T-9" 9'-0" 9'-7" 8'-1" 9'-2" 9' 11" 11'-4" 1 11'-8" 12'-3" 14 3" BLE NOTES: ALLOWABLE WABLELE NCALULATBADN -10 IG RISK10SSNLOSEXPPRESSURESVALIDUP TO 30' MRH. EXP'C' & EXP'D' PRESSURES ALID UP TO 15' MRH ONLY. DEFLECTION LIMIT AS NOTED IN CLEAR SPAN TABLES, MAXIMUM 4LLOWABLE ROOF SLOPE SHALL BE 3" MAX PER FOOT (3:12). ANEL DEAD LOADS HAVE BEEN FACTORED INTO CALCULATIONS FOR 3RAVITY LOADS AS WELL AS CALCULATIONS FOR PANEL PROPERTIES. MAXIMUM ALLOWABLE ROOF OVERHANGS FOR THE VALUES LISTED ABOVE SHALL NOT EXCEED 3'-0". MAXIMUM ALLOWABLE SIDE OVERHANG IS 25% OF LAST PANEL WIDTH. (i.e. 12" MAX FOR 48" ANEL WIDTH). t) INDICATES ROWS FOR USE WITHIN THE HVHZ ONLY. DEFLECTION IMITS CONSIDERED FOR USE IN THE HVHZ ARE: L/80 FOR SPANS :512'-0" L/180 FOR SPANS > 12'-0" CLEAR SPAN TABLES . DIRECTIVE: 1. CHOOSE TYPE OF ENCLOSURE TO BE COVERED SCREENED WALLS, OR FULLY ENCLOSED). 2. VERIFY APPROPRIATE ALLOWABLE LIVE LOAD, I WIND SPEED AND EXPOSURE CATEGORY WITH GOVERNING MUNICIPALITY AND BUILDING CODES IN EFFECT FOR THE PROJECT LOCATION USING FLORIDA BUILDING CODE. 3. FIND ALLOWABLE COMPOSITE PANEL CLEAR SPAN IN TABLES FOR APPROPRIATE PANFL DEPTH, i FACING THICKNESS, AND EPS CORE DENSITY i SELECTED. I; 4. ANCHOR COMPOSITE PANELS TO EXISTING HOST STRUCTURE AND EXISTING SUPPORTING MEMBERS AS ILLUSTRATED HEREIN. 15 lorida Building Code Online c- https://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVX... µpsivki ,,.k.;: :, . ,` x azbfi ! ,,.,,i," "' w - ham. r n ::.: •>. auW,. a,.::i`s`" ,¢ • x e..,ar,3 t.....,., ,wta.:ii;aiw„u u^r. E :..vYs'»ts S:ew iws,a;? r BCIS Home Log In User Registration Hot Topics Submit Surcharge j Stats & Facts Publicat Business' Professl vo',;'` O USER: Product Approval! i I Public User . Product Approval Menu > Product or Application Search > Aoolication List > Application Detail FL # FL161-R5 Application Type Revision Code Version 2014 Application Status p rovedComments Archived Product Manufacturer Custom Window Systems Inc Address/ Phone/Email 1900 SW 44th Avenue Ocala, FL 34474 352) 368-6922 ekoss@cws. cc Authorized Signature Koss Erin ekoss@cws. cc Technical Representative Erin Koss Address/ Phone/Email 1900 SW 44th Ave. Ocala, FL 34474 352) 368-6922 Ext 291 ekoss@cws. cc Quality Assurance Representative Jay Lathrop Address/ Phone/Email 1900 SW 44th Ave. Ocala, FL 34474 352) 368-6922 Ext 291 jlathrop@cws. cc Category Exterior Doors Subcategory Swinging Exterior Door Assei of 3 3/1/2016 11:56 AM Florida -Building Code Online https://www.florid/abuildiiig.org/pr/pr_app_dtl.aspx? aram=wGEVX. C d-- t-8 a C Q..- l.i Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory u r T snhmit Surcharae Stats & Facts Publicat Custom Window Systems Inc 1900 SW 44th Avenue Ocala, FL 34474 352) 368-6922 ekoss@cws.cc Koss Erin ekoss@cws.cc Erin Koss 1900 SW 44th Ave. Ocala, FL 34474 352) 368-6922 Ext 291 ekoss@cws.cc Jay Lathrop 1900 SW 44th Ave. Ocala, FL 34474 352) 368-6922 Ext 291 jlathrop@cws.cc Windows Horizontal Slider 2/22/2016 12:4-7 1 of 3 City of Sanford Building and Fire Prevention Permit # z Project Location Address 6 1 ? 7 As required by Florida Statute 553.842 and Florida Administrative Code 9N-3, please provide the information and product approval number(s) on the building components listed below if they are to be utilized on the construction project for which you are applying for a building permit. We recommend that you contact your local product supplier should you not know the product approval number for any of the applicable listed products. Be aware that windows, skylights, and exterior doors must be tested in accordance with the Florida Building Code, Section 1714.5. More information about Statewide Product Approval can be obtained at www.floridabuilding.org. The following information must be available on the jobsite for inspections: 1. This entire product approval form 2. A copy of the manufacturer's installation details and requirements for each product. Category / Subcategory Manufacturer Product Description Fl(,rida Approval # include decimal) 1. Exterior Doors Swinging Sliding Sectional Roll U Automatic Other 2. Windows Single Hun orizontal Sli Casement Double Hun Fixed Awning Pass Through Projected Mullions Wind Breaker Dual Action Other June 2014 Category/,Subcategory Manufacturer Product Description Florida Approval # including decimal) 3. Panel Walls Siding Soffits Storefronts Curtain Walls Wall Louver Glass block Membrane Greenhouse E.P.S Composite Panels Other 4. Roofing Products Asphalt Shingles Underla ments Roofing Fasteners Nonstructural Metal Roofing Wood Shakes and Shingles Roofing tiles Roofing Insulation Waterproofing Built up roofing System Modified Bitumen Single Ply Roof Systems Roofing slate Cements/ Adhesives / Coating Liquid Applied Roofing Systems Roof Tile adhesive Spray Applied Polyurethane E.P.S. Roof s oast 's ntj r,, T v-rad Roof Vents Other June 2014 Category/•Subcategory Manufacturer Product Description Florida Approval # include decimal) 5. Shutters Accordion Bahama Colonial Roll up Equipment Other 6. Skylights Skylights Other 7. Structural Components Wood Connectors / Anchors Truss Plates Engineered Lumber Railing Coolers/Freezers Concrete Admixtures Precast Lintels Insulation Forms Plastics Deck / Roof Wall Prefab Sheds Other 8. New Exterior Envelope Products Applicant's Signature Applicant's Name Please Print) June 2014 L- P 7% M CITY OF SANFORD I I BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: o7y Documented Construction Value: $ 500.00 Job Address: 618 Sarita Street Sanford, FI 32773 IIiStOrlC District: Yes No Parcel ID: 01-20-30-504-0900-0170 Residential 0 Commercial Type of Work: New 0 Addition Alteration Repair Demo Change of Use Move Description of Work: Electrical wiring of a Glass Sunroom Plan Review Contact Person: Steve Thomas - Title: owner Phone: 407-323-6958 Fax: 407-323-1154 Email:• ticelectricinc@bellsouth.net Property Owner Information Name Mindy Matthews Phone: 407-322-8888 Street: 618 Sarita Street Resident of property? : yes City, State Zip: Sanford A 32773 Contractor Information Name TLC Electric Inc Phone: 407-323-6958 Street: 2534 Park Dr Fax: 407-323-1154 City, State Zip: Sanford FI 32773 State License No.: ECO02027 Architect/Engineer Information Name: Phone: Street: Fax: City, St, Zip: E-mail: Bonding Company: Mortgage Lender: Address: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST. BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR 'LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. t certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5°i Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application i NOTICE: In addition to the requirements, of this Hermit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713._ The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zo ing. Signature of Owner/Agent Date Si nature of Contractor/Agent Date La (j C) U Print Owner/Agent's Name Print Contractor/ gent'siName Signature of Notary -State of Florida Date Signature of Noted. c ntMH LIAE P,iY r lq1^tu510N k r MW ExpiPE& R40W.' e z n Fubl;cUndenari!s Owner/Agent is Personally Known to Me or Contractor/Agent is Personally Known to Me or Produced 1D Type of 1D Produced ID Type of lD BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing[] Gas[:] Roof Construction Type: Occupancy Use: Flood Zone: Total Sq Ft of Bldg: Min. Occupancy Load: # of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes No # of Heads Fire Alarm Permit: Yes No APPROVALS: ZONING: UTILITIES: WASTE WATER: ENGINEERING: FIRE: BUILDING: COMMENTS: Revised:.tune 30, 2015 Permit Application