Loading...
HomeMy WebLinkAbout2403 Sanford Ave; 17-2277; HVAC & DUCT WORKCITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: Documented Construction Value: $ gbe o, C"d 0 Job Address: 763 SsvY, .tt, r. SSA-,./, ; 3 27 7 / Historic District: Yes No Parcel ID: Residential 0 Commercial Type of Work: New Addition Alteration Repair Demo Change of Use Move Description of Work: Plan Review Contact Person: Title: P4, ce_4' c P Phone: g6?_f1t_o7jy Fax: Email: SO-4dr- 1.4-0-' e V,Cv '— 0;.1 Property Owner Information Name IdAa-el y IL'_ %o S Street: Z V6 -3 S'gin pocd City, State Zip: S4nWa- Phone: Resident of property? : Y,,eJ Contractor Information Name .CL _-erytc--s =7'1, C. Phone: qo-)- kl y- O -z-Vl Street: 2_3 ooA <yllcityet" All-e„ Fax: 07 I y_ a3 k,3 City, State Zip: , /.'!( ,C. 327o 3 State License No.: C-4C / ,SG yJ Name: Street: City, St, Zip: Bonding Company: Address: Architect/ Engineer Information Phone: Fax: E- mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. ^ FBC 105. 3 Shall be inscribed with the date of application and the code in effect as of that date: 51 Edition (2014) Florida Building Code Ft Revised: June 30, 2015 Pemut Application U o 1 I -6onat restri.edons applicable to this property that may beNOTICE. rat addition to the requirements of this permit, there =y be add-, found in the public records of this county, and there may be additioml. permits required from other governmental entities such as water management districts, state agencies, or federal agencies. kcceptance of permit ts,,erification that I c,vill notify— 6e owner of the property of the requirements of Florida Lien fa%,,,, I-S, 7D The City of Sanf6rd requires payment of plan review fee at the time of permit subnurtal. A copy of the executed, contract is required review the tiMC,Cf SubillittAl. in. order to calculate a plan review charge and will be considered the esdinated construction value of the job y The actual construction• value will be figured, based on the current FCC Valuation, Table in effect at the time, the permit is issued., in accordance tLrith, local. ordinance. Should calculated charges figured off the executed contract exceed the actml construction valne, credit will be applied to your permit fees when the permit is issued:. OWNIF,W,S -AFFIDAVIT- I certify that all of the foregoing information is accurate and that all. work will be done in compliance with all 2PPUc3ble lams regalafincr construction and Zoning. rp sipawle Q--Nonry-smre. OILE106da 2 7 Y4 2 1 s, N-0 DatePriat Gnntt dorlAgmnfs NL-C m2rv-state of Rod& a IN, D31C a JOSENFOFFER C USSON0% 10ExRRES:AP ' F9 Known to Me or Contractorjkgent is Y— Personally Knc wn to D Produced ID TypeoflD_ BELOW IS FOR OFFICE USE ONLY Gwrncr/Agreat is Personally Produced ID Type of lager e of Me or Pe-rmitsRequired: Building[] Electrical Mechanical W Plumbine flZI Construction Type: Total Sq Ft of Bldg. occupancy Use: Alin. Occulmney Load: Ne v Construction: Electric - # of soaps GasO Roaf D Flood Zone: of Stories: pt-umbing - # of Fixtures Were SprinUer Permit: Yes F1 Igo #of Heads Fire Alarm Permit: Yes 11 N!-GF ApPROVALS: ZONIING: UTILITIES: -WASTE WATER- ENGrNTEERING: FIRE: BUILDING: COMMENTS: Rv,rised. June 30,2015 Permit Applicatioll Job: 2403 SANFORD AVENUE RManualSComplianceReportpp Date: Jul 11, 2017 By: TRICIA HIGGINS SPEEDY CALC'S LLC 2805 STATEN DRIVE, DELTONA, FL 32738 Phone: 407 314-8495 Fax: 407 322-5788 Email: SPEEDYCALCS@YAHOOO.COM Web: wWW.SPEEDYCALCS.COM For: MICHAEL & HEATHER FOSTER, OWNER BUILDER 2403 SANFORD AVENUE, SANFORD, FL 32771 Design Conditions outdoor design DB: 93.0°F Sensible gain: 35824 Btuh Btuh Outdoor design WB: 75.2°F Latent gain: 6091 41915 Btuh Indoor design DB: 75.0°F Total gain: 1533 cfm Indoor RH: 50% Estimated airflow: Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Actual airflow: 1533 cfm Sensible capacity: 36340 Btuh Latent capacity: 9660 Btuh Total capacity: 46000 Btuh Design Conditions Outdoor design DB: 40.9°F Indoor design DB: 70.0°F Model: 25H NB648A00310+F E4AN F005L++U I 101% of load 1590/6 of load 110% of load SHR: 79% Heat loss: 40350 Btuh Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HNB648A00310+FE4ANF005L++UI Actual airflow: 1533 cfm Output capacity: 46500 Btuh 115%o of load Supplemental heat required: 0 Btuh Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1533 cfm Output capacity: 8.0 kW 68% of load Temp. rise: 21 °F Meets are all requirements of ACCA Manual S. Entering coil DB: 75.9°F Entering coil WB: 62.9°F Entering coil DB: 69.6°F Capacity balance: 36 OF Economic balance: -99 OF 2017-Jul-14 18:47:15 wrightsoft' RightSuiteO Universal 2017 17.0.23 RSU08373 Page 1 cuments\Wrightsoft HVAC12403 SANFORD AVENUE.rup Calc = MJ8 Front Door faces: N Job: 2403 SANFORD AVENUE Date: Jul », 2017ProjectSummary By: TRICIA HIGGINS SPEEDY CALLS LLC 2805 STATEN DRIVE, DELTONA, FL 32738 Phone: 407 314-8495 Fax: 407 322-5788 Email: SPEEDYCALCS@YAHOOO.COM Web: WWW.S11 PEEDYCALCS. COM For: 24103 SANFORD THER AVENUE, SANFORD, FL OWNER BUILDER Notes: Load Calculation was obtained via electronic copy of drawing Weather: Winter Design Conditions Outside db 41 °F Inside db 70 'F Design TD 29 °F Orlando Sanford, FL, US Heating Summary Structure 36140 Btuh Ducts 4210 Btuh Central vent (0 cfm) 0 Btuh none) 0 Btuh Humidification0BtuhPiping Equipment load 40350 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 Heating Cooling Area ( ftz) 2426 2426 Volume ( ft') 21175 0. 32 21175 0. 16 Airchanges/hour 113 56 Equiv. AVF (cfm) Heating Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HNB648AO0310 AHRI ref 9161086 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat Capaatybalance point= 36 °F 9 HSPF 46500 Btu h @ 47° F 28 F 1533 cfm 0. 038 cfm/Btuh 0. 50 in H2O Backup: Input = 8 kW, Output = 27297 Btuh, 100 AFUE Summer Design Conditions Outside db 93 °F Inside db 75 ' F Design TD 18 °F Daily range M e Relative humidity 50 /e Moisture difference 39 gr/lb Sensible Cooling Equipment Load Sizing Structure 30641 Btuh Ducts 5183 0 Btuh Btuh Centralvent (0 cfm) none) 0 Btuh Blower Use manufacturer's data 0 1.0 Rate/ swing multiplier 35824.00 Btuh EquipmentsensibleloadLatent Cooling Equipment Load Sizing Structure 5084 1008 Btuh Btuh Ducts Central vent (0 cfm) 0 Btuh none) 6091 EquipmentlatentloadBtuh Equipment Total Load (Sen+Lat) 41915 Btuh Req. total capacity at 0.79 SHR 3.8 ton Cooling Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING 10 Co' lld FE4AN 005L+0+ UI f 9161086 AHRIreEfficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 12. 5 EER, 16 SEER 36340 Btuh 9660 Btuh 46000 Btuh 1533 cfm 0. 043 cfm/Btuh 0. 50 in H2O 0. 85 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2017- Ju1-14 18:47:15 wri htsoft' Rig htSuite®Universa1201717.0.23RSU08373 Page 1 cuments\ Wrightsoft HVAC 2403 SANFORD AVENUE.rup Calc = MJ8 Front Door faces: N Job: 2403 SANFORD AVENUE I r COI'1' portent Constructions Date: Jul 11, 2017 w` s By: TRICIA HIGGINS SPEEDY CALC'S LLC 407 322-5788 Email: SPEEDYCALCS@YAHOOO.COM Web: WWW.SPEEDYCALCS.COM2805STATENDRIVE, dELTONA, FL 32738 Phone: 407 314 8495 Fax: For: MICHAEL & HEATHER FOSTER, OWNER BUILDER 2403 SANFORD AVENUE, SANFORD, FL 32771 Indoor: Heating Cooling Location: Indoor temperature (°F) 70 75 Orlando Sanford, FL, US Design TD (°F) 29 18 Elevation: 56 ft Relative humidity N 50 50 Latitude: 29'N Heating Cooling Moisture difference (gr/lb) 24.6 38.7 Outdoor: 41 93 Infiltration: Dry bulb (°F) 17 (M) Method Simplified Dailyrange (°F) 75 Construction quality Average Wind spWetbulbeed (mph) 15.0 7.5 Fireplaces 0 Or Area U-value Insul R Htg HTM Loss CIg HTM Btuh BtuhlW Gain Btuh Construction descriptions 1p (" ..F ft-"FBtuh BNh/W Walls n BLOCK WALL R3: Blk wall, 8" thk 484 0.333 3.0 3.0 9.69 9.69 4690 5930 8.67 8.67 4199 5309 a 612 0.333 456 0.333 3.0 9.69 4417 8.67 3954 s w 543 0.333 3.0 3.0 9.69 9.69 5262 20300 8.67 8.67 4710 18172 all 2095 0.333 Partitions none) WindowsCODEMINIMUM: 2 glazing, cir low-e outr, argon gas, insulated vinyl frm n 16 0.400 0 0 11.6 11.6 186 372 9.94 24.724.7 159 791 mat, cir innr, 1/2" gap, 1/4" thk; 50% blinds 45", mediurn; 50% outdoor s 0.400320.400 0 11.6 372 318 insect screen; 1.4 ft overhang (4 ft window ht, 1.4 ft sep.}; 6.67 ft 32 0.400 0 11.6 372 24.7 791 w head ht all 112 0,400 0 11.6 11.6 1304 105 18.4 24.7 2060 223 CODE MINIMUM: 2 glazing, cir low-e outr, argon gas, insulated vinyl frm e 9 0.400 p mat, cir innr, 1/2" gap, 1/4" thk; 50% blinds 45", medium; 50% outdoor 1.4 ft overhang (3 ft window ht, 1.4 ft sep.); 6.67 ftinsectscreen; 0 11.6 37 9.94 31 head ht lCODEMINIMUM: 2 glazing, cir low-e outr, argon gas, insulated vinyl frm s 3 0400 mat, clr innr, 112" gap, 1/4" thK 50% blinds 45", medium; 50% outdoor 1.4 ft overhang (2 ft window ht, 1.4 ft sep.); 6.67 ftinsectscreen; 0 11.6 873 24.7 1855 head htCODEMINIMUM: 2 glazing, dr low-e outr, argon gas, insulated vinyl frm w 75 0.400 mat, cir innr, 10 gap, 1/4" thk; 50% blinds 45", medium; 50% outdoor insect screen; 1.4 ft overhang (5 ft window ht, 1.4 ft sep.); 6.67 ft head ht Doors none) Ceilings 030.0 0.93 2259 1.75 4235 16B- 30ad: Attic ceiling, asphalt shingles roof mat, r-30 ceil ins, 1/2" 2426 .032 gypsum board int fish 2017- Jul-14 18:47:15 wrightsoft` Right -Suite® Universal2017 17.0.23 RSU08373 Page 1 Z51 ... cuments\Wrightsoft HVAC\2403 SANFORD AVENUE.rup Calc = MJ8 Front Door faces: N Floors 22A-tpl: Bg floor, light dry soil, on grade depth 266 0.989 0 28.8 7655 20W-Jul-14 18:47:15 c , + wright$aft' Right -Suite® Universal 2017 17.0.23 RSU08373 Page 2 i c"a.... cumentslWrightsoft HVAC2403 SANFORD AVENUE.rup Calc = MJ8 Front Door faces: N Job: 2403 SANFORD AVENUE AED Assessment Date: Jul 11, 2017 By: TRICIA HIGGINS SPEEDY CALC'S LLC 2805 STATEN DRIVE, DELTONA, FL 32738 Phone: 407 314-8495 Fax: 407 322-5788 Email: SPEEDYCALCS@YAHOOO.COM Web: WWW.SPEEDYCALCS.cOM For: Location: Orlando Sanford, FL, US Elevation: 56 It Latitude: 29°N Outdoor: Dry bulb (°F) Dailyrange (T) Wet bulb CF) Wind speed (mph) MICHAEL & HEATHER FOSTER, OWNER BUILDER 2403 SANFORD AVENUE, SANFORD, FL 32771 Heating Cooling 41 93 17 (M 75 15.0 7.5 Indoor: Heating Indoor temperature ('F) 70 29DesignTD (T) 50Relativehumidity (%) Moisture difference (gr/lb) 24.6 Infiltration: Hourly Glazing Load Har d W/ Holly i Avo" Maximum hourly glazing load exceeds average by 45.8%. House does not have adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 650 Btuh (PFG-1.3*AFG) Cooling 75 18 50 38.7 2017-Jul-14 18:47:15 ti r wrightsoft' RightSuite® Universal2017 17.0.23 RSUD8373 Page 1 cuments\Wrightsoft HVAC\2403 SANFORD AVENUE.rup Calc = MJ8 Front Door faces: N a4a Righter Worksheet SPEEDY CALC'S LLC Job: 2403 SANFORD AVENUE Date: Jul 11, 2017 By: TRICIA HIGGINS c--;I ePCGnvCAI cSraYAH000.COM Web: WWW.SPEEDYCALCS.COM Calculations approved by ACCA to meet all re uirements of Manual J 8th Ed. 2017Jul-14 18:47:15 414- wrightSoft' RightSuite® Universal 201717.0.23 RSU08373 Page 1 cuments\Wrightsoft HVAC\2403 SANFORD AVENUE.rup Calc = MJ8 Front Door faces: N Right -JCS Worksheet SPEEDY CALLS LLC Job: 2403 SANFORD AVENUE Date: Jul 11, 2017 By: TRICIA HIGGINS r— - 1—Q D6-- An711d11dQ9 car 4n7 322-5788 Email SPEEDYCALCS(COYAH000.COM Web: WWW.SPEEDYCALCS.COM Calculations approved bv ACCA to meet all re uirements of Manual J 8th Ed. 2017-Juh14 18:47:15 wrightscift' RightSuite® Universal 2017 17.0.23 RSU08373 Page 2 Aeek cuments\Wrightsoft HVAC12403 SANFORD AVENUE.rup Calc = MJB Front Door faces: N Right-JO Worksheetar, Job: 2403 SANFORD AVENUE x Date: Jul 11, 2017 By: TRICIA HIGGINS SPEEDY CALC'S LAC c7uu -2prrnYCAt CSOYAHOOO.COM Web: WWW.SPEEDYCALCS.COM ri1q "--1*n Right-Sulte® Universal2017 17.0.23 RSU08373 AC ...cuments\Wrightsoft HVAC12403 SANFORD AVENUE.rup Ca1C = MJ8 Front Door faces: N 2017-Jul-1418:47:15 Page 3 R1 ht Wolrksheet Job: 2403 SANFORD AVENUE g Date: Jul 11, 2017 By: TRICIA HIGGINS SPEEDY CALVS LLC 1 ......, 1 — , —1 c t.cr cPFFnYCALCS8YAHOOO.COM Web: WWW.SPEEDYCALCS.COM Calculations approved by ACCA to meet all re uir ments of Manual J 8 h Ed. r 2017-Jul-141$:47:15 TFWrrightSoft" Right -Suite® Universal 2017 17.0.23 RSU08373 Page cuments\ Wrightsoft HVAC\2403 SANFORD AVENUE.rup Calc = MJ8 Front Door faces: N Right-JU Worksheet SPEEDY CALC'S LLC Job: 2403 SANFORD AVENUE Date: Jul 11, 2017 By: TRICIA HIGGINS en7111_s,7aa r-,.il• RPFFOYCALCSCCDYAHOOO.COM Web: WWW.SPEEDYCALCS.COM Calculations approved by ACCA to meet all _requirements of Manual J 8th Ed. 2017-Ju1-14 18:47:15 TAT- wri9htsoft' RightSuite@ Universal 2017 17.0.23 RSU08373 Page 5 cuments\Wrightsoft HVAC2403 SANFORD AVENUE.ruP Calc = MJ8 Front Door faces: N 3 Right-JO Worksheet SPEEDY CALC'S LLC Job: 2403 SANFORD AVENUE Date: Jul 11, 2017 By: TRICIA HIGGINS r, 111— -- An7 zld-idn5 Far- dn7 322-5788 Email: SPEEDYCALCS@YAHOOO.COM Web: WWW.SPEEDYCALCS.COM Calculations approved by ACCA to meet all re uirements of Manual J 8th Ed. 2017-Jul-1418:47:15 wri ht50ft" Page 9 Right-Suite®Universal 2017 17.0.23 RSU08373 cuments\Wrightsoft HVAC\2403 SANFORD AVENUE.rup Catc = MJ8 Front Door faces: N Job: 2403 SANFORD AVENUE Right WOrICSIleetAN"M Date: Jul 11, 2017 By: TRICIA HIGGINS SPEEDY CALC'S LLC 2805 STATEN DRIVE, DELTONA, FL 3273E Phone: 407 314-8495 Fax: 407 322-5788 Email: SPEEDYCALCSQa YAHOOO.COM Web: WWW.SPEEDYCALCS.COM 1 Room name LIVING ROOM 2 Exposed wall 35.0 ft 9.0 ft heaticool 3 Room height 1.0 x 515.0 ft 4 Room dimensions 515.0 ft' 5 Room area Ty Construct on U-value Or I HTM Btuhlft') I Area (ft2) or perimeter (ft) I Load Btuh) ( Area ( or perimeter load number Btuhtfl'-°F Heat Cool Gross NIP/S Heat Cool Gross NIPIS Heat Cool 6 Vp BLOCK WALL R3 0.333 n 9.69 8.67 0 0 0 0 0 0 0 t--G CODE MINIMUM 0.400 n 11.64 9.94 0 0.333 a 9.69 8.67 99 99 959 859 BLOCK WALL R3 24.73 0 0 0 0T=CODE MINIMUM 0.400 a 11.64 0 0 0 11 CODE MINIMUM 0.400 a 11.64 24.73 0 0 0 Y f BLOCK WALL R3 0.333 s 9.69 8.67'' 0 0 0 0 0 0 1 CODE MINIMUM 0.400 s 11.64 9.94 0 0 0 0 G CODE MINIMUM 0.400 s 11.64 9.94 0.333 w 9.69 8.67 216 171 1657 1483 BLOCK WALL R3 CODE MINIMUM 0.400 w 11.64 24.73 0 0 0 0 CODE MINIMUM 0.400 w 11.64 24.73 45 0 0.032 - 0.93 1.75 515 515 524 480 111 899 C 16B-30ad F 22A-tpl 0.989 28.78 0.00 515 35 1007 0 421 6 c) AED excursion 4627 4775 Envelope lossigain 495 153 12 a) Infiltration 0 0 b) Room ventilation 13 Internal gains: Occupants Qa 230 0 700 0 Applianceslother 51 22 5628 Subtotal (lines 6 to 13) 0 0 Less external load 0 0 Less transfer 529 632 Redistribution 5651 6260 14 Subtotal 1290 17°„ 658 105 9 15 Duct loads 6310 7313TotalroomloadII240IAirrequired (cfm) of Manual J 8th Ed. Calculations a roved hy ACCA to meet all re uirements 2017-Jul-14 18:47:15 f wrightsoft' RightSuite®Universal 201717.0.23RSU08373 Page cumentslWrightsoft HVACQ403 SANFORD AVENUE.rup Calc = MJ8 Front Door faces: N Duct System Summary SPEEDY CALC'S LLC Job: 2403 SANFORD AVENUE Date: Jul 11, 2017 By- TRICIA HIGGINS 2805 STATEN DRIVE, DELTONA, FL 32738 Phone: 407 314-8495 Fax: 407 322-5788 Email: SPEEDYCALCS@YAHOOO.COM Web: WWW.SPEEDYCALCS.COM For: MICHAEL & HEATHER FOSTER, OWNER BUILDER 2403 SANFORD AVENUE, SANFORD, FL 32771 Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O 0.26 in H2O Pressure losses 0.26 in H2O 0.24 in H2O 0.24 in H2O Available static pressure Supply / return available pressure 0.148 / 0.092 in H2O 0.148 / 0.092 in H2O Lowest friction rate 0.076 in/100ft 0.076 in1100ft 1533 cfm Actual air flow 1533 cfm 315 ItTotaleffectivelength (TEL) Design Name (Btuh) Htg cfm) Clg cfm) Design FR Diam H x W in) (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk 4 0.111 4.0 Ox 0 VIFx 18.2 115.0 st2 97 2BATH1c h 501 19 17 0.106 4.0 Ox 0 VIFx 23.8 115.0 st2 BATH 3 BEDROOM h 4659 177 153 0.103 7.0 Ox0 VIFx VIFx 29.0 33.7 115.0 160.0 st2 st3 BEDROOM 2 h 5591 212 207 0.076 0.097 8.0 Ox 0 7.0 Ox 0 VIFx 32.0 120.0 st2 BEDROOM 3 h 4046 154 154 130 130 0.096 7.0 Ox 0 VIFx 28.1 125.0 st2 BEDROOM 3-A h 4046 61 51 0.108 5.0 Ox 0 VIFx 21.8 115.0 st2 DEN h 1616 2733 45 117 0.113 6.0 Ox 0 VIFx 21.0 110.0 stlKITCHENc LAUNDRY h 3347 127 107 0.115 6.0 Ox 0 VIFx 18.0 32.0 110.0 155.0 stl st3 LIVING ROOM c 3659 120 157 0.079 7.0 Ox 0 7.0 Ox 0 VIFx VIFx 18.0 150.0 st3 LIVING ROOM -A c 3659 120 157 88 0.088 0.100 6.0 Ox 0 VIFx 33.4 115.0 stl M BATH -A h 3037 115 215 0.104 0 Ox 0 VIFx 32.0 110.0 stl M BEDROOM h 5953 226 TrunkWI Clg Desigr Name TypeCfm) FR st3 Peak AVF520 0.07 st2 Peak AVF1006 0.07 SO Peak AVF527 0.10 Veloc Diam H x W Duct fpm) in) in) Material Trunk j 662 12.0 0 x .0 7VinIFIx st2 B 953 14.0 0 x 0 VinIFIX 3 671 12.0 0 x 0 VinlFix 2017-Jul-14 18:47:16 wrightSOft` RightSuite® Universal 2017 17.0.23 RSU08373 Page 1 cuments\Wrightsoft HVACU403 SANFORD AVENUE.rup Cale = MJ8 Front Door faces: N Jame Grille Size (in) Htg cfm) rb4 Ox 0 212 rb3 Ox 0 177 rb1 Ox 0 327 rb2 Ox 0 342 rb5 Ox 0 476 TEL ft) Design FIR• Veloc ' fpm) Diam in) H x W in) Stud/Joist Opening (in) Duct Matl TrunkClg cfm) 107.0 109.0 121.1 67.0 62.0 0.060 0.060 0.060 0.060 0.060 481 507 599 626 425 9.0 8.0 10.0 10.0 16.0 Ox 0 Ox 0 Ox 0 Ox 0 Ox 0 VIFx VIFx VIFx VIFx VIFx rt1 rt1 rt1 rt2 rt2 207 153 277 303 593 Trunk Htg Clg Type cfm) cfm) KrtIPeakAVF 716 637akAVF817896 Design Veloc Diam H x W in) Duct Material Trunk FR fpm) in) 0.060 670 14.0 0 x 0 VinlFlx 0.060 642 16.0 0 x 0 VinlFlx 2017-Jul-14 18:47:16 wrightSOft' Right -Suite® Universal 2017 17.0.23 RSU08373 Page 2 cuments\Wrightsoft HVAC%2403 SANFORD AVENUE.ruP Calc = MJ8 Front Door faces: N Job: 2403 SANFORD AVENUE Static Pressure and Friction Rate Date: Jul 11, 2017 By: TRICIA HIGGINS SPEEDY CALC'S LLC 2805 STATEN DRIVE, DELTONA, FL 32738 Phone: 407 314-8495 Fax: 407 322-5788 Email: SPEEDYCALCS@YAHOOO.COM Web: WWW.SPEEDYCALCS.COM For: MICHAEL & HEATHER FOSTER, OWNER BUILDER 2403 SANFORD AVENUE, SANFORD, FL 32771 External static pressure Pressure losses Coil Heat exchanger Supply diffusers Return grilles Filter Humidifier Balancing damper Other device Available static pressure Measured length of run -out Measured length of trunk Equivalent length of fittings Total length Total effective length Supply Ducts Return Ducts Supply Return Heating Cooling in H2O) in H2O) 0.50 0.50 0.10 0.1C 0 0 0.03 0.011: 0.03 0.01, 0.10 0.1C 0 0 0 0 0 0 0.24 0.24 Supply Return ft) ft) 19 18 15 23 160 80 194 121 315 Heating Cooling in/100ft) in/100ft) 0.076 OK 0.076 0.060 OK 0.060 4X=35, 11C=40, 11G=5, 11G=5, 11C=40, 1A=35: TotalEL=160 6M=20, 11C=40, 11G=5, 5E1=10, 11G=5: TotalEL=80 OK OK 2017-Jul-14 18:47:16 wrightSOft' RightSuite® Universal 2017 17.0.23 RSU08373 Page 1 cumentstWrightsoft HVA=403 SANFORD AVENUE.rup Calc = MJ8 Front Door faces: N RECORD COPY N u Sheet 1 REVIEWED FOR .CODE COMPLIANCE BEDROOM 3 o 7. 7• 94xi4 PLANS EXAMINER toxs 327ctm I 10x8 154 Cfm 154 CfM DATE 4'BATH 3 12x12 8x 81 DEN 19 5" 12x6 177 cfm MBATH LAUNDRY e x 10x8 4d 7" 10 x B 127 dm BAT 1 BEDROOM 1 115 Ctrs 6' 6' 4' 14' 1 14' 8' 14x8 24 x 12 226 dm t 177 ctm 8. KI HEN 6' k 14 x 14 16 • LIVING ROOM 9 MBEDROOM 342dm tOxB 117 d 8• 10' 12x6 12x8 12x12 14x8 157 dm 157 eim 212 dm 212 cfm 7' 7 BEDROOM 2 MINING 18 x 18 93 cfm SANFORD BUILDING DNISION A PERMIT ISSUED SHALL BE CONSTRUED TO BE A LICENSE TO PROCEED WITH THE WORK AND NOT AS AUTHORITY TO VIOLATE, CANCEL, ALTER OR SET ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING A CORRECTION OF ERRORS IN PLANS, CONSTRUCTION OR VIOLATIONS OF THIS CODE Job #: 2403 SANFORD AVENUE Performed by TRICIA HIGGINS for: MICHAEL & HEATHER FOSTER 2403 SANFORD AVENUE SANFORD, FL 3277T SPEEDY CALC'S LLC 2805 STATEN DRIVE DELTONA, FL 32738 Phone: 407 314-8495 Fax: 407 322-5788 WWW.SPEEDYCALCS.COM SPEEDYCALCS@YAH Scale: 1 : 125 Page t RightSuiteO Universal 2017 17.0.23 RSUG8373 2017-Jul-1418:48:06 oft HVAC\2403 SANFORD AVENI 1--a!0W 4Somw UVAMiSR APPLIA.NlCE SERVICES Prepared For: Mike Foster 2403 Sanford Ave. Sanford, F1. 32771. Date: June 21, 2017 Job Description: 4 Ton. A/C System Install with New Duct Work Installation of New (ICP) 4 Ton Straight Cool Split System with 10 kw of Heat and New Duct Work as well as, Copper piping Materials, Drain Materials, New Thermostat and Drain Safety Switch, Auxiliary Drain Pan and Float Switch, Hanging Hardware and Misc. Hardware and other materials needed to complete the Install as per Mechanical Code. Also will need a Drawing, Energy Calc. and Permit for the Install. PRICING 16 SEER 1CP System ........ $2600.00 4 Ton Straight Cool W/ 10 KW Heater) Duct Materials .... All New Over Head Duct Work) Permitand Drawing Fee........................................................................... Labor............................................................................................. Total............................................................................................. Customer Signature: THANKS) SEAN REECE lyr Labor Warranty and 10yr Manufacture's Parts Warranty ) 2200.00 1000.00 2200.00 8000.00 25 Wall Street, Ste 7 Orlando, FL 32801 Phone/Fax (407)839-8989 THIS INSTRUMENT P EPARED BY: Name: r Address: I d r, cr G NOTICE OF COMMENCEMENT State of Florida County of Seminole Permit Number: 11 - 9yi% —7 Parcel ID Number: 3I _1 % —.- % — S/ !— pro —-,, -zel The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 4v OF P 3 Ire-fi i.,, 9-lGC-S t- A U 7, UT/Y -'i o. S lam/' (, f -73. i GENERAL DESCRIPTION OF IMPROVEMENT: W47 Y V,--u/ o OWNER of the orc oerty and street address if Address: ? Y a S Svl +- crcq vl EIC Fee Simple Title Holder (if other than owner) Name: Address: CONTRACTOR: J - Name:_,,; , kk Address: 23 6-e 6 S Li c f Z. rti z 33. rl aS'sSI jLere,-f,+ : P 13 .3 P e L Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served as provided by Section 713.13(1)(b), Florida Statutes. Name: In addition to himself, Owner Designates of To receive a copy of the Lienor's Notice as Provided in Section 713.13(1)(b), Florida Statutes. Expiration Date of Notice of Commencement (The expiration date is 1 year from date of recording unless a different date is specified) %/ '7 / f WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalties of perjury, I declare that I have read the foregoing and that the facts stated in it are true to the best of my knowledge and belief. Ovine' s Si .lure Owner's Printed Name Florida Statute 713.13(1)(g): ' The owner must sign the notice of commencement and no one else may be permitted to sign in his or her stead.' County of The fo goi g instrument was knowledged before me this` J / day of ' 2D l / I ' by ,• r / Who i known to Name of person making slalemmil OR w)10 has produced identification 12type of identification produced. l ! / r\ r•TO" SHAAONB. CATlANEONotary Public -StateofFloridajNotarysinafureCommissionAFF 232829 My Comm. Expires Aug 26, 2019