Loading...
HomeMy WebLinkAbout248 Fairfield Dr; 17-2234; SOLAR PANELSJob Address: 24 -} Qr lab j ', . Historic District: Yes No Parcel TD: ; Z - 19 - 3 1 - 5 (5 - 0000 - J-7 o O Residential Commercial Type of Work: New Additionf9 Alteration Repair Demo Change of Use Move Description of Work: 11J5-(e r Lr —1 • 5 4 (C._ItJ P ltbT- \Jd 1,Z Aa L 5 S T l." 2-00 I hA o 0 N Try O c S Plan Review Contact Person: M P<,I P, Mi A-OC Title: T--QI\A I T -rt G to Phone'_12-1 - 2 -1 _:Fax: Email: Property Owner Information C w Name JEE F F_ P-1i VIA D1 S vt,l _V42- Phone: 3 2.1 - 2-4 to - Q 2 q 5_e Street: 2-} 1 A -I g=F 1 C L D, D L- Resident of property? City, State Zip: Sogt,,r-oR-l. L Z-1-1 1 Name Street Contractor Information Ld I-I SDU YL l t'1 ozT LS EPhone l S w G0Wt•3kk-L— D "z3113 Fax: 1 z1— Zj -1— 9 313 City,StateZip: V3Itsfae-- r(, 3HZT1 State License No.: GLI°joa4 613 Architect/Engineer Information Name Street: City, St, Zip: Bonding Company: Address: Phone: Fax: E-mail: _ Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 51' Edition (2014) Florida Building Code Revised: June 30. 2015 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Signature of Owner/Agent Print Owner/Agent's Name Date Signature of Notary -State of Florida Date Owner/Agent is Personally Known to Me or Produced ID Type of ID 0,--o I - 21 - [7 Signature of Contractor/Agent Date Print Contractor/Agent's Name 1 —7-1 —' 7 Date EXPIRES: MARIA C. MEADE My COMMISSION # GGS4091 December I1, 2020 Contractor/Agent is Personally Known to Me or Produced ID Type of ID dl-- BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing Gas Roof Construction Type: Total Sq Ft of Bldg: Occupancy Use: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: Yes No # of Heads APPROVALS: ZONING: "2.-] UTILITIES: ENGINEERING: COMMENTS: le FI.RE: Flood Zone: of Stories: Plumbing - # of Fixtures Fire Alarm Permit: Yes No WASTE WATER: BUILDING: 5 8' 1041 Revised: June 30, 2015 Permit Application CFA Parcel Information Property RecordCard Parcel: 32 '9 3t 515 0000.0 700 Owner: Property Address: 248 F.AIRS ELD DR SANF(JRD, FL 32771 Value Summary 2017 Working 2016 Certified Values Values Valuation Method Cost/Market Cost/Market Number of Buildings 1 Depreciated Bldg Value 145,294 125,490 Depreciated EXFT Value Land Value (Market) 30,000 23,000 Land Value Ag WUSOJlarket valut, 175,294 148,490 Portability Adj Save Our Homes Adj 54,205 29,892 Amendment 1 Adj P& G Adj 0 0 Assessed Value 121,089 118,598 Tax Amount without SOH: $2,063.00 1, 464.00 Tay, E'.,dmatm Save Our Homes Savings: $599.00 Does NOT INCLUDE Non Ad Valorem Assessments Legal Description LOT 70 CELERY LAKES PHASE 1 PB 62 PGS 75 & 76 Taxes Taxing Authority Assessment Value Exempt Values Taxable Value County General Fund 121,089 55,000 66,089 , Schools 121,089 30,000. 91,089 City Sanford 121,089 55,000 66,089 SJWM( Saint Johns Water Management) 121,089 55,000 66,089 , County Bonds 121,089 55,000 66,089 1 Sales Description Date Book Page Amount Qualified Vac/Imp SPECIAL WARRANTY DEED 12/11/2012 U. 793C9 1,34 148,900 No Improved CERTIFICATE OF TITLE 6/1/2012 IS 161 1 100 No Improved QUIT CLAIM DEED 7/11/2005 015i'll 31 00195 100 No Improved SPECIAL WARRANTY DEED 6/11/2004 el,)'Sa,, 0 - 79i'i 158,400 Yes Improved Find Comparable Sales Land Method Frontage Depth Units Units Price Land Value LOT 1 30,000.00 30,000 Building Information is Bed .PBa'ncount incorrccl? Cll--k Hcrc. Year Built Description i Fixtures Actual/Effective Bed Bath Base Area I Total SF Living SF Ext Wall Adj Value Repl Value Appendages 1 2004 13 4 3:0 1,364 3,424 3,012 145,294 152,540 Description Area Scanned by CarnScanner EVILUE SKY S CHOICE Contractor's Authorization Letter I, T"Co (, s l —6EW , license holder for Ok-JM aLarL 12, , authorize the following people to apply/sign for permits under my license number el- i3 u q'T13 Please allow the person(s) listed below to sign. Contractor's Signature n)AC `D, r ( I n Contractor's Printed Name STATE OF FLORIDA COUNTY OF PINELLAS The foregoing instrument was before me this day of , 20 lq- by Ste) o urh.p to acknowledged who is personally known to me or has produced LLL as identification. STEP8ANIF_ STEPHEN Nly COMMISSION # FF218087 NOTA J`&jnq`' EXPIRES April 07. 2019 ti; r r 3y;:-C' NaxtallotryService.corr License # EC13004873 Blue Sky Solar Energy 970 Lake Carillon Dr., 3rd Floor, Saint Petersburg, FL 33716 800-588-1950 REQUIRED INSPECTION SEQUENCE BP# BUILIDING PERMIT Min Max Inspection Description Footer / Setback Stemwall Foundation / Form Board Survey Slab / Mono Slab Prepour Lintel / Tie Beam / Fill / Down Cell Sheathing — Walls Sheathing — Roof Roof Dry In Frame Insulation Rough In Firewall Screw Pattern Drywall / Sheetrock Lath Inspection Final Solar Final Firewall Final Roof Final Stucco / Siding Insulation Final Final Utility Building Final Door Final Window Final Screen Room Final Pool Screen Enclosure Final Single Family Residence Final Building (Other) Address: Minn Marx I[ns ection Descri tion Electric Underground Footer / Slab Steel Bond Electric Rough T.U.G. Pre -Power Final Electric Final vgw Min Marx Inns ection Descri tion Plumbing Underground Plumbing Sewer Plumbing Tub Set Plumbing Final MEC HAN I CAL; PERMIT . Min I Max Min I Marx Mechanical Roug Mechanical Final Gas Unde Gas Roug Gas Final REVISED: June 2014 Design 1 1< N ; f IRS !F1 i_, D1 <, A Design e Components Design Design 1 Component Name DC Nameplate 7 54 kW Inverters SE7600 (240V) (SolarEdge) Combiners 1 input Combiner AC Nameplate 7.63 kW (0.99 DC/AC) Combiners 2 input Ccmbirer Last Modified sam ksl (Today at 2:00 PM) Strings 10 AWG (Copper) Optimizers P300 (Sol3rEdge) Q Project Location Modules SolarWo ld. Sunmodule SW 290 mono (290W) M Field Segments Count 1 (7.6316W) 1 1 2 (17.2 tt) 26 (7.80 kW) 26 (7.54 kW) Description Racking Orientation flit Azimuth Intrarow Spacing Frame Size Frames Modules Power F10d Segment i Flush Mount Vertical (Portmir) 18.4' 180' 0.0It 1.1 16 16 4.64 kW Field Segment 2 Flush Mount Horizontal (Landscape) 18.4' 180` 0.0 h 1,,1 10 10 2.90 kw c3a Wiring Zones Description Combiner Poles String Size Stringing Strategy Wiring Zonn 12 8-18 Along Racking 2017 Folsom Labs 212 July 13, 2017 Photovoltaic System Approval Certificate UM-16-0208A Awarded to: UMA Solar 950 Sunshine Lane Altamonte Springs, FL 32714 For The Photovoltaic System Designated: SOLEDGE3 - SW290 - SE760OA-US PV Modules and Array Array Configuration PV Module Manufacturer: SolarWorld Total Number of PV Modules: 21-34 PV Module Model Number: Sunmodule Plus SW290 Mono Series Strings/Branch Circuits: 2 FSEC Module Registration Number: SW15-ACTL-0429 Modules Per Series String/Branch Circuit: 8-18 Listing to UL 1703 Verified: Yes Array Nameplate Power Rating: 6,090 to 9,860 W Power Conditioning Equipment (Inverter) Inverter DC Voltage Window: 350 V to 600 V Inverter Manufacturer: SolarEdge AC Power Rating: 7,600 W Inverter Model Number: SE760OA-US AC Nominal Voltage Output: 240 V Listing to UL 1741 Verified: Yes Max PV Array Power Per Inverter: 9,500 W Charge Controller and Batteries Battery Manufacturer: N/A Charge Controller Manufacturer: N/A Battery Model Number: N/A Charge Controller Model Number: N/A Battery Type: N/A Listing to UL 1741 Verified: N/A Battery Capacity (C/20 rate): N/A Battery Bank Configuration Total Number of Batteries: N/A Number in Each Series String: N/A Number of Series Strings: N/A Comments Electrical Design (Verify the following items for agreement between the installed components and the supplied electrical schematic.) Size, type and location of all conductors in the PV system; Conduit, raceways, junction boxes, and combiner boxes; Size, current rating, voltage ratings, and location of all over -current protection devices; Rating and location of all disconnects; Point of connection to the utility; PV module and equipment grounding system (including conductor size); PV DC circuit and system grounding (including grounding electrode conductor size); Ground fault detection & interrupter (GFDI) rating and location; Battery wiring and cable sizes (if applicable). Inspection Inspector Name (printed) Installer Information and Certification Company Name: Address 1: Inspector Signature Website: Address 2: City: State: Phone Number: Fax Number: Florida Contractor License Number: Florida Contractor License Type: ( ) Solar ( ) Electrical ( ) Other, please specify: I hereby certify that this PV system has been installed in full accordance with the National Electrical Code. Installer Name (printed) Installer Signature Zip: Note: FSEC approvals do not replace or exempt any requirements of electrical utilities or local jurisdiction authorities in matters such as permitting, inspections, or utility interconnection agreements as required for PV system installations. When referring to FSEC approvals in any documentation produced by the supplier, including technical or marketing information, the following statement shall be included: The photovoltaic system design described in th man 1, whe operly installed and maintained, meets the minimum recommended practices established by the Florida Solar Energy Center. This 'approval' does not imply elors nt oranty of this product by the Florida Solar Energy Center or the State of Florida." Provided by: 2016-07-12 Solar Tes Ing & Certification Coordinator Date Date Date I^\ OBTAIN All PER AND WROVAIS FROM GOVERNING AGFNOES PROVIDE WAPMNG'ELECTRIC SHOCK HAZARD. DO NOT TOUCH FRRMINMS.RB-ALS ON BOTH LEE MAD LOAD SIDE MAY BE Pi PRICE TO THE COMMEN[FMEM OF WORK ENEROZ® N IM OR POSD W SIGN PRI NEC 6% T7. fii7 FOU.YPMENT SHALL N NSTAII[D PER THE ZLII I HADONM RFCTRCM CODE MKL ALL APRUCARLE OR GOVFRMN'G CODES, AMNUFA — LARK DEA10E m NECRRO.NyCBZL ARpSR AND SECURE mNBC ER0.7EDf. V REOURREMIIAS OP AND PER THE GOVERNING UIDIY COMPANY. LL, Si US —AGENT NAME AND NUMBER SMALLN INDICATED e\ LABEL WRITER NKERPER 690s4, 70s.11(0)ANp7Os.I o. I TD0(6{ TO PREVENT AN INCREASE IN AC VOLTAGE IMt AND AVOID ANY TV BAOLFEED CURRENT PLUS MAN BREAR9 RAIR.G MUST BE LESS MAN OR f QNUSANCEFAULTS,PIS RECOMMENDED TO SIZE CONWCTORFOR A 9\ EWAL TO 120%OF MAIN SERVICE BUS RATING AND BREAKERS MUST BEDROPOFZ'A. ALL CONDUCTORS SHOWN SIZED FOR AMPAOTY MY. AMOUNTED AT OPPOSITE END OF MAW NEARER PER NEC 705.I2 METALLIC CONDUIT SHALL BE USED WIIIRN THE BUILDING F0OT.N7 PER LAR E ANCDON WX, CON" SOY, CISCONN ECTS, AND ENERGIZED HIC 00.3I IEF UNGROUNDED ORCUITS PR W RRD]S AMMNMv Wmyt [HM [ANTE IN`-r SAADI ma iR.w, NNAA»oN IMmmnw-. I I Y R.w cmLRMAmRaRla KONpurtR]R>MNRHHM a.vc saDDlwuAav DAaPowaAAA caMMa rMxNIDWNRA .mMs oRw,n omwaRs w aBa=1=1 fit_{ F- MOT. 3 3 a N 9^ c o g qpF WC6m- 0DT6 r ouwTiBr_ T`ItmNO. R i1 SCAU A5 WiED pAAaaNDa SWSUK , ? FE: NEC 2011 LABELING REQUIREMENTS PHOTOVOLTAIC AC DISCONNECT I—IUM—VtATINGCUIIRENT', 31A MAXIMUMACOPEPATRaOVIXT— 140V PERNK650.54 PROVIDEATEXRRN41. OISCONNECT/MA01sERVIQPANEL/ERWsF f PANEL FOR SOLAR PV IF APPFKAMEI PHOTOVOLTAIC TYPE INFORMATION HERE) AC DISCONNECT PERNECRR9.141C)11)&610.1E PROVIOEATMER EXTFPHPI AC DNCONNKT OP N SYSTEM NEARER NVUA—E PANES CEaOML IMFRTERSY5TEM5 RATED MAX POWER -POINT CURRENT: 18.66Adc RATED MAX POWER -POINT VOLTAGE: 3SO.O Vdc MAXIMUM SYSTEM VOLTAGE: 500.0 Vdc MAXIMUM SHORT CIRCUIT CURRENT: 19.94 Adc PER NEC690.51) - PROVIDE AT INVERTER INTEGRATED AC/DC Of CONNECT - FOR SINGLE STRING SYSTEMS WARNING DUAL POWER SOURCE SECOND SOURCE IS PV SYSTEM LABEL PER NK M15.111M(4)- PMMOE AT MAN1 SEMICE —EL . TAP "LOCAT— CIRCUIT PANEL DIRECTORY Na. va cNCLYr ce6raRATCN: Ra Eoua avEam.Irw mAM a.cara+KroarPl6cnro vRFOaaEOPMNEB >1 aaECtOa PHOTOVOLTAIC TYPE INFORMATION HERE) DC DISCONNECT PER NEC 690.14(C)(2) & 690.15 - PROVIDE AT EITHER INVERTER INTEGRATED AC/DC DISCONNECT OR EXTERNAL OC DISCONNECT WARNING ELECTRIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION u&i PM xFc6aV-PMVtOF ArMNN SFnv4F PaMt WARNING INVERTER OUTPUT CONNECTION - DO NOT RELOCATE THIS OVERCURRENTDEVICE 1aS WONT nON MAIN PV SYSTEM DISCONNECT PEN NEC 650.14(11' PROIIOE AT MAIN SERVICE PANE1 OR NBV SERVICE PANELPOR SOLAR PV E OR SUPPLY 510E CIXINECTNIN ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED. DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT Pea Mc aw.I nn aao sm1sl. Pmna.r iavraaa PHOTOVOLTAIC POWER SOURCE NOTE: PROVIDE AT ALL DC CONDUIT, RACEWAY, ENCLOSURES, CABLE ASSEMBLIES AND JUNCTION BOXES PER NEC 690.31 (E)(3). 10 FT MAX SPACING PER NEC 690.31(E)(4). sola=se SolarEdge Single Phase Inverters For North America SE3000A—US SE300OA—US / SE5000A- US / SE6000A—US / SE7600A-US % SE10000A— S / SE11400A—US w a r erte, CS e F dY[4QftJ.fst DmCe4Pb z The best choice for S61arEdge enabledsystem., Specifically designed to work with power optimizers Integrated arc fault protection for NEC 2011 690.11 cornpliance w Rapid shutdown for NEC 2014 690.12 Superior efficiency (98%) Small, lightweight and easy to Install on provided bracket Built-in module -level monitoring Internet connection through Ethernet or Wireless Outdoor and indoor installation Fixed voltage inverter, DC/AC conversion only Pre -assembled Safety Switch for faster installation Optional — revenue grade data, ANSI C12.20 A - CAP4ADA - G!iPNIANa 1"AI.r FRANCE - MPAN . CHINA A JS?RAL€P. - THE. >dE"'H¢.P.LANDS UK - ISRAEL 7JRKEY - S0L;TH AFR1`A- SJLGARiA www.solaredge.us solar=e"Single Phase Inverters for North America SE3000A US / SE3800A--US / SE5000A-US / SE600OA-US SE7600A-US / SEI0000A-US SE1140OA-US SE300OA-US SE380DA US SESOOOA-US SE600OA-US . SE760OA-US SHOW A- US LSE1140OA-US OUTPUT Nominal AC Power Output 3000 3800 5000 6000 7600 9980 @ 208V 11400 10000.E 40V Max. AC Power Output 3300 4150 5400 @ 203V 6000 8350 10800 @ 208V 12000 5450 @240V 10950 @240V AC Output Voltage Min: Nom.-Max ' 183 - 208 - 229 Vac AC Output Voltage Min: Nam: Max.' I f 211 - 240 - 264 Vac AC Frequency tvlin.-horn: Max.: S9.3 60 - 60.5 Max. Continuous Output Current 12.5 16 24 cl 203V 2S 32 48 @ 208V 47 S i. 21 @ 240V 42 @ 240V.. GFDI Threshold 1 Utility Monitoring, Isianding Protection, Country Configurable Thresholds Yes Maximum DC Power (STC) 4050 5F00 67SO 8100 10250 13500 15350 Transformer -less, Ungrounded Yes Max. Input Voltage 500 Nom. DC Input Voltage , 325 @ 208V / 350 @ 240V Max Input Currents) 9.5 13 16.5 @ 208V i8 23 33 @ 208V 34,5 15.S.t?,240V 305,@140V..!. Max. Input Short Circuit Current 45 Reverse -Polarity Protection Yes Ground -Fault Isolation Detection 600Iw Sensitivity Maximum Inverter Efficiency 97.7 98 2 98.3 98.3 98 98 98 CEC Weighted Efficiency 97.5 9S 97 @ 208V 97.5 97.5 97 @ 208V 97.5 98 240V..... 97.5,E NOV j................. Nighttime Power Consumption 2.5 4 ADDITIONAL FEATURES Supported Communication Interfaces RS48S, RS232, Ethernet LigBee. (optional) Revenue Grade Data, ANSI C12.20 Optionall" Rapid Shutdown - NEC 2014 690.12 Yes STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, UL1998, CSA 22.2 Grid Connection Standards IEEE1547 I ....... missions .._......- FCC partly class B INSTALLATION SPECIFICATIONS VA VA i Hz A A. Yes W vdc Vdc Adc Adc W/ AC output conduit size ! AWG range 3/4" minimum / 16-6 AWG 3/4" minimum / 8-3 AWG DC input conduit size j# of strings / 3/4' minimum J 1-2 strings / 16-6 AWG 3/4' minimum / 1-3 strings / AWG range ...... 14-6 AWG Dimensions with Safety Switch 30.5x12.5x7.2%775x315x184 30.5 x 12.5 x 10.5 j in / HxWxD) _ ..... ........ .. ....:....... 775,x315x,260. .. _min ... Weight with Safety Switch 57..2 / 23,2 54.7 / 24.7 88.4 / 40.1. lb / kg Natural convection Cooling Natural Convection and internal Fans (user replaceable) fan (user replaceable) .'. Noise < 25 < 50 Min. -Max. Operating temperature Range. _ .. : 13 to +140 i -25 to +60 (AO to +60 version available l01) Protection Rating NEMA 3R For other regional settings please contact SolarEdge support. A higher current source may be used; the inverter will lint its input current to the values stated. l" Revenue grade inverter P/N: 5ExxxxA-USWONNC2. - 141 40 version P/N: SExxxxA U5000NNU4 (for 7600W invertec5E76WA U5002NNU4l. dBA F/'C.. solar -.. :. SolarEdge Power Optimizer Module Add -On For North America P300 / P320 / P370 / P400 / P405 PV power optimization at the module -level Up to 25% more energy Superior efficiency (99.5%) Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading Flexible system design for maximum space utilization Fast installation with a single bolt Next generation maintenance with module -level monitoring Module -level voltage shutdown for installer and firefighter safety A CANADA- GERMANY - ITALY - FRANCE - WAN- CHINA • AUSTRAL'A -THE NETHEREAND5 -UK - ISRAEL- WK•EY •SOUTH =?li: cU GAfiIA - iNDIA 4vww.solaredge.us solar -• SolarEdge Power Optimizer Module Add -On for North America P300 / P320 / P370 / P400 / P405 P300 P320 P370 P400 P405 for 60-cell mod- (for higher -powerforhigh -power (for 72 & 96-cell for thin film 60 and 72-cell ules) 60-cell modules) modules)i modules) modules) INPUT Rated Input DC Power"' T...... 300 320 370 400 405 W Absolute Maximum Input Voltage Voc at lowest temperature) 60 8o f 125 Vdc MPPT Operating Range b' - 48 - 6 8 . 80 3 12.5 - 105 Vdc Maximum Short Circuit Current 0sc) 1fi 11 10.1 Adc Maximum DC Input Current i 2 5 13.15 12.63 Adc Maximum Efficiency 99.> Weighted Efficiency 98 8 Overvoitage Category OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Cu! r.=ni 1S Adc Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optimizer 1 VdC STANDARD COMPLIANCE EMC FCC Part15 Class B, IEC61000-6.2, IEC61000-6-3 Safr.,ty IEC621.09-1 (class 11 safety), UL1741 ROHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed Sy,t m Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions (W x L x H) 128x152x35/ 128x152x27.5/5x5.97x1.08 128x152x50/ mm/in 5x5.97x1.37 Sx5.97x1.96 Weight (including cables) 630 / 1.4 750 / 1.7 845 / 1.9 gr / lb Input Connector MC4 Compatible MC4 / MC4 Compatible Amphenol AH4 Double Insulated; Output Wire Type / Connector Double Insulated; MC4 Cornpabble MC4 / Double insulated: MC4 Compatible Amphenol AH4 Dut ut Wire LengthPg 3.0 1.2/3.90.95 .... _ - _ ... m/ft Operating Temperature Range 40 - +85 / -40 - +185 C / 'F Protection Rating IP68 / NEMA6P Relative Humidity 0 - 100 Rated SIC power of the module. Moduleof up to *S%power tolerance allowed. PV SYSTEM DESIGN USING A SOLAREDGE I NVERTERM SINGLE PHASE SINGLE PHASE THREE PHASE 209V HD - WAVE THREE PHASE 480V Minimum String Length Power Optimizers) 8 10 18 Maximum String Length 25 25 50 Power Optimizers) .. ... ....... ... Maximum Power per String 5700 ( 6000 with 5250 6000 1 12750 W SE7600H- US) ._... ... !,......._-........`...._ Parallel Strings of Different Lengths or Orientations _ ...... ..... Yes i" For detailed string suing information refer to: http://www.solaredge.com/sites/default/files/string_sizing na.pdf- tri it is not allowed to mix P405 with P300/P370/P400/P600jP700 in one string. Sunmodule,;," Pius SW 290 - 300 MONO SolarWorld's foundation is built on more than 40 years of ongoing innovation, continuous optimization and technology expertise. All production steps from silicon to module are established at our production sites ensuring the highest possible quality for our customers. Our modules come in a variety of different sizes and power, making them suitable for all global applications — from residential solar systems to large-scale power plants. Extremelytough and stable, despite its light weight — able to handle loads up to 178 psf (8.5 kN/m=) Tested in extreme weather conditions— hail -impact tested and resistant to salt spray, frost, ammonia, dust and sand Proven guarantee against hotspots and PID-free to IEC 62804-1 SolarWorld Efficell'" PERC cell technology for the highest possible energy yields 1 rrrrr r ._ . ;:.. rr. (h,allty TP_sif-fl MADE IN USA OF US & IMPORTED PARTS 10. 4004fAW, Patented corner design with integrated drainage for optimized self-cleaning High -transmissive glass with anti -reflective coating Z Long-term safety and guaranteed top performance — 25-year linear performance warranty; 20-year product warranty www.solarworld.com Sunmodulei Plus SW 290 - 300 MONO PERFORMANCE UNDER STANDARD TEST CONDITIONS (STC)` SW 290 SW 295 SW 300 Maximum power V., 290 Wp 29S Wp 300 Wp Open circuit voltage V, 39.6 V 39.8 V 40.0 V powerMaximum point voltage V,- 31.9 V 32.3 V 32.6 V Short circuit current 9.75 A 9.78 A 9.83 A Maximum power point current L,.., 9,20 A 9.25 A 9.31 A Module efficiency 17.3 % 17.59 % 17.89 % Measuring tolerance (Pm„) traceable to TUV Rheinland: +/ 2% (TUV Power controlled, ID 00000393Si) STC:1000W/m2. 25'C, AM IS PERFORMANCE AT 800 W/m2, NOCT, AM 1.5 Maximum power Open circuit voltage Maximum power pc Short circuit current voltage SW 290 SW 295 SW 300 f`,„„ 219.6 Wp 223.6 Wp 226.7 Wp V. 36.7 V 36.9 V 37.0 V V„,rF 29.5 V 29.9 V 30.2 V I, 7.99 A 8.01 A 8.06 A Maximum power point cu ren t I, w 7 43 A 7.47 A 7.52 A Minor reduction in efficiency .0 dei partial load ccnd i e v, at ?5'C, at 200 W/mz, 97% (+/-3%) of the STC efficiency (1000 W/mz) is achieved. PARAMETERS FOR OPTIMAL SYSTEM INTEGRATION Powersorting -0 Wp/+5 Wp fr E - - ,:"• L.i \! r Maximum system voltage SC ll , NEC 1000 V Maximum reverse current -__ _ 25 A 37,8 (961) - Number of bypass diodes 3 Operating temperature -40 to +85 °C 106.65 O Maximum design loads (Two rail system)* 113 psf downward, 64 psf upward vz y 712 zi 0.26 (6.6) Maximum design loads (Three rail system)' 178 psf downward. 64 psf upward 180.85) Please refer to the Sunmodule costa€lation instructions for the details associated with these Icad cases 0.35(9 COMPONENT MATERIALS o 0 Cells per module 60 Cell type Monocrystalline PERC Cell dimensions 6 in x 6 in (156 mm x 156 mm) Front Tempered safety glass with ARC (EN 12150) a Back Multi -layer polymer backsheet, white 6 Frame Black anodized aluminum J-Box IP65 Connector PV wire (UL4703) with Amphenol UTX connectors Module fire performance (UL 1703) Type i DIMENSIONS / WEIGHT THERMAL CHARACTERISTICS 11.32 287.50) Length 65.95 in (1675 rnm) NOCT 46 °C Width 39.40 in (1001 mm) TC1" 0.07%/C 39.4 (7001) Ii Height 1.30 in (33 mm) TCV -0.29 % /C t.30 (33) Weight 39.7 lb (18.0 kg) TC p ,n, -0 39 % /C All units provided are imperial. 51 units provided in parentheses. ORDERING INFORMATION CERTIFICATES AND WARRANTIES Ordernumber Description IEC61730 IEC61215 UL1703 82000482 Sunmodule Plus SW 290 mono (black frame) Certificates IEC 62716 IEC 60068-2-68 IEC 61701 82000430 Sunmodule Plus SW 295 mono (black frame) Product Warranty 20 years Warranties ' 82000432 Sunmodule Plus SW 300 mono (black frame) Linear Performance Guarantee 25years Supplemental warranty coverage available through SolorWorld Assurance" Warranty Protection Program - wwwsolorwarld.com/assurance SolarWorid AG reserves the right to make specification changes without notice. This data sheet complies with the requirements of EN 50380. V10O 6 10 0 0 3 s 9 1 g 1 7 6 5 n 3 2 1 B E Q O W U H Lu C Z a ro N E Lu — C) ELIN U (D z O 3 U a 8 RESIDENTIAL GENERIC STRUCTURAL PLAN. THIS PLAN SHALL NOT BE USED FOR SYSTEMS LARGER THAN 10-kW OR COMMERCIAL PROJECTS. LARGER RESIDENTIAL & ALL COMMERCIAL PV INSTALLATIONS REQUIRE SITE -SPECIFIC PLANS. IRONRIDGE PV RAIL GENERIC INSTALLATION PLAN THIS PAPER PLAN IS INTENDED TO PROVIDE THE ESSENTIAL INFORMATION NEEDED BY AHJ (AUTHORITY HAVING JURISDICTION AKA BUILDING DEPARTMENT) AND INSTALLERS.USERS ARE ENCOURAGED TO ACCESS EV ( ELECTRONIC VERSION) OF THIS PLAN. ACTIVE HYPERLINKS ON EV PROVIDE EASY ACCESS TO SUPPLEMENTAL INFORMATION. EV ALSO ALLOWS VIEWER TO STUDY THE PLAN AND OEM (ORIGINAL EQUIPMENT MANUFACTURER) DETAILS AT MAGNIFICATION OF VIEWER CHOICE UP TO 6400 % . IF A CONFLICT SHOULD OCCUR BETWEEN A DRAWING AND/OR SPECIFICATIONS HEREON AND AN OEM DETAIL, OEM SHALL PREVAIL. THIS IS A SINGLE SHEET GENERIC PLAN. CONTRACTOR SHALL PROVIDE AHJ WITH SITE -SPECIFIC INFORMATION AS REQUIRED. THIS PLAN OFFERS THREE INSTALLATION METHODS. 1. FRAMING METHOD. SEE DRAWING. 2. SHEETING METHOD. SEE DRAWING. 3. STANDING SEAM METAL ROOF. USE CLAMP OF CHOICE; a. ACE". http://wW W.pmcind.rom/ar eclamp/ b. S-5!'". http://www.s-5.conVclamps/ c. TRA". httpJ/trasnowandsun.com/product-categorylsolar-mounting/ SOLAR EQUIPMENT ADDS LESS THAN 4-PSF GRAVITY LOAD TO STRUCTURE. THERE SHALL BE A PV MODULE TO RAIL MOUNTING AT EVERY MODULEIRAIL CROSSING POINT WITH MINIMUM 4 CLAMPS PER MODULE. ADJOINING MODULES SHALL SHARE CLAMPS. MODULES MAY BE LANDSCAPE OR PORTRAIT AT CONTRACTOR OPTION. ROOF IS ASSUMED TO BE FRAMED WITH TRUSSES ON 24-INCH CENTERS & DECKED WITH s " PLYWOOD. CONTRACTOR SHALL VERIFY AND SHALL NOTIFY FOR ( ENGINEER OF RECORD) IF DIFFERING CONDITIONS EXIST & SHALL FOLLOW FOR INSTRUCTIONS IF ISSUED AS CONSEQUENCE OF DIFFERING CONDITIONS. PV MOUNTING RAILS SHALL BE INSTALLED PERPENDICULAR TO ROOF FRAMING. SEE ROOF ATTACHMENT SPAN TABLE HEREON. THERE SHALL BE A MINIMUM OF TWO RAILS UNDER EACH PV MODULE. RAILS SHALL NOT CANTILEVER BEYOND OUTSIDE OF END ROOF ATTACHMENT BY MORE THAN 1-FOOT. RAILS SHALL ATTACH TO ROOF THRU L-FEET ROOF AS SHOWN HEREON. L-FEET REQUIRE FLASHINGS WHICH CAN BE SF -SO (SELF -FLASHING, SHEETING ONLY) ROOF ATTACHMENTS SHOWN HEREON OR 4" x8 " x MIN. 26 GA. ALUMINUM SHEET OR INDUSTRY STANDARD OEM FLASHINGS LAGGED INTO ROOF FRAMING SUCH AS SOLAR MOUNT, IRONRIDGE FLASHFOOT, OR OTHER ACCEPTABLE TO AHJ. SF-FO ROOF ATTACHMENTS ARE INTENDED TO BE INSTALLED INTO SHEETING ALONE. HAVE BEEN SO TESTED AND ARE RATED AT 900-POUNDS ALLOWABLE PER ROOF ATTACHMENT. ALL FLASHINGS SHALL BE INSTALLED IN A GENEROUS BED OF FLORIDA PRODUCT CONTROL APPROVED(PCA) POLYURETHANE ROOF SEALANT. OPTIONAL STANDOFFS ARE PERMITTED AS NEEDED FOR ADDITIONAL ROOF CLEARANCE. CONTRACTOR SHALL PROVIDE AHJ (AUTHORITY HAVING JURISDICTION) ADDITIONAL INFORMATION AS MAY BE REQUESTED. FOLLOW OEM INSTALLATION INSTRUCTIONS FOR ALL DETAILS SHOWN HEREON. ENGINEER OF RECORD (EOR) PREFERS EMAIL COMMUNICATION; allen@gezelmanpe.com 01 ENGINEERING NOTES. SCALE NTS PV RAIL READY FOR ROOF MODULES I SELF -FLASHING WITH FL-PCA SEALANT I I YPICAL CONCRETE TILER LADY FOR SEALANT 9 WiBF ALLOWABLE OS SHEETING ATTACHMENT ALE: MS MIN. 4EA..e12,SS.SMS1'THRUDECx OEM TESTED FACTORY/FIELD 9 8 1 7 I CERTIFY THAT THE SHEETING AND FRAMING OF THIS STRUCTURE WILL SAFELY ACCOMMODATE CALCULATED WIND UPLIFT AND LATERAL FORCES AND EQUIPMENT DEAD LOADS. THIS IS ATTESTED TO BY MY SIGNATURE AND SEAL ON THIS DRAWING AT THE UPPER RIGHT, VOID WITHOUT RAISED OR ELECTRONIC SEAL, MAY NOT BE USED FOR PLANS ON FILE, EVERY PERMIT PULLED REQUIRES A SEALED ELECTRONIC PLAN OR SEALED ORIGINAL PAPER COPY OF THE PLAN. CONTRACTOR SHALL IDENTIFY DETAILS USED TO o DESIGNED FOR V =200 MPH., LL CONTRACTOR SHALL CHANGE/ADJUST THIS PLAN AS REQUIRED TO l RISK III, EXPOSURE D. SATISFY FBC (INCLUDING REFERENCED STANDARDS), AHJ, JOBSITEAHJAUTHORITYHAVINGJURISDICTION` ULT w CONSTRAINTS, & OEM DOCUMENTATION HARDWARE APPEARANCE MAY VARY, SUCH AS, ROUND HEAD BOLTS OR HEX HEAD BOLTS ARE EQUALLY ACCEPTABLE. PV MODULE SERRATED L ROOF MOUNT 5/16" CPS. LAG W/ 3" THREAD EMBEDMENT IN BLOCKING, JOIST, OR TRUSS 02 FRAMING METHOD SCALE: NTS j - 16 x j HEX HEAD BOLT Is - 16 FLANGE BOLT MID -CLAMP - 16 x HEX HEA s - 16 FLANC IRONRIDGE RAIL EXIST. ROOF SERRATED L ASPH. SHINGLE ROOF MOUNT ROOF MEMBRANE WATER PROOFING EXISTING TOP CORD OF TRUSS 5I CRS. LAG W/ THREAD EMBEDMENT IN BLOCKING, JOIST, OR TRUSS 03 METAL ROOF ATTACHMENT SCALE: NR 4 RAIL METHOD I PZ1 PZ2 P73 - FRAMING 4-FT 4-FT 2-FT XR 3000 SHEETING 10-FT 8-FT 6-FT End Clamp 1Md Ckalgl Ak-b— IIi11Ik iYM J IRONRIDGE XR IMB RAIL & COMPONENTS ALE: NTS SRA MAY BE ROUND OR SQUARE. BED IN COMPATIBLE ROOF SEALANT, HEAT WELD TARGET ON TOP RAIL & L-FOOT INSTALLED ON TOP OF ROOFING TARGET 07 SINGLE -PLY ATTACHMENT ALE: NTS HEAT WELDING OUTER EDGE OF TARGET TO EXISTING ROOF MEMBRANE FOR REDUNDANT WATER -PROOFING PV MOUNTING SYSTEM READY FOR MODULE INSTALLATION e-16x$HEY HEAL DULE e - 16 FLANGI IRONRIDGE RAIL XIST. METAL DECKING IN ROOF SHEETING WATER PROOFING STING TOP RD OF TRUSS WATER PROOFING WITH SONOLASTIC NP-1 OR EQUAL POLYURETHANE CAULK LAMP DULE RIDGE RAIL RRATED L ROOF MOUNT NGTHENING NEEDED. EXIST. ROOF TILE TILE ROOF STANDOFF OF MBRANE 04 SHEETING METHOD SCALE NTS Proper Flashing Placement FLASH®iRUCTI --. SELF -FLASHING. SHEETING -ONLY ROOF ATTACHMENTS. 08 SCALENTS 09 SGLEH NTS Classic Composition Mounting Instructions ?A Tu1. Ma.M.""."", •En.N+w rw+"Mwn rLmearouid.,xmmdM.Mw"h . r ACE'., CLAMP r,+. r.wr .....".Nw. ...sr. TRA, r+ MOUNTING j CLAMP L SHINGLE MOUNTING INSTRUCTIONS POVED STANDINGEAM SCLAMPSSCALE: NTS SPRcZ NTS 6 1 5 4 1 3 1 2 FLORIDA BUILDING CODE FBC 2014 IST" EDITION) ENGINEER ALLEN GEZELMAN A 16502 HANNARD. LUTZ. FLORIDA 33549 PH.813 909 1956 Allen@GezelmanPE.com Www.GezelmanPE. com PE 59180 N 2 9 281 1 B IAIpericeli@I RAFTSMAN: APERICELI mail. ust. ed z O J I Lu D (7 o0 O= 2z IZ = CONTRACTOR: r.+ x C; 970 Lake Ceram. 3rd Floor St Petersburg. FL 33716 EC13004873 Emag: Info@Nueskysofamnwgy. eon, Phone:(800) 588-1950 C IN E AI- IR 5-EDIT 24.02. 17 F 1 RECORD COPY REVIEWED FOR CODE COMPLIANCE PLANS EXAMINER 14. t'7 DATE SANFORD BUILDING DIVISION A PERMIT ISSUED SHALL BE CONSTRUED TO BE A LICENSE TO PROCEED WITH THE WORK AND NOT AS AUTHORITY TO VIOLATE, CANCEL, ALTER OR SET ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING A CORRECTION OF ERRORS IN PLANS, CONSTRUCTION OR VIOLATIONS OF THIS CODE BUILWol ogNFoRD AgRTM N 1 7- 223 4 J lt! `.ij`edT ('1t'jLtl`t : N.t9 I i`dI?1_.E t::r ii;`i ; ,I Permit Number _ ER1;. 0 F Cl RCLi1-1 C0Lf'tT & CtNP-1 R0LLE":1R a `<Q f1TaxFolio/Parcel ID 3A.9,:ICLERK'S aw 2017082 91 NOTICE OF COMMENCEMENT i;L=:C0RDED i:l? '1c!1.117 11 17 "_7 r'ji1 THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property;~.iT. if-ifit,'bW-,&rdaU.-e%wii itiiA ter 713, Florida Statutes, the following information is provided in this Notice of Commencement: 1. Description of property: (legal description of property, and street address if available) ,G4%..._.... 7iJ...... G.11el 2. General description of improvement: Install New Photovoltaic Solar 3. Owner information: a. Name and address://1-d b. Phone number: ....... _/......... O c. Name and address of fee simple titleholder (if other than owner): 4. Contractor: a. Narne and address: Blue rgy; 1 5 W. CQLQnid-Driy-e-AZ$3113, Winter Carden FL 3477$ b. Phone number: $ 00-$$$-1950 CEn71fIFu' r 5. Surety: CLEIRK Of THE CIRCU! i COURT Gq, a. Name and address: N/A AND COMil"I'ROLI-FR b. Amount of bond 5: 6. Lender: a. Name and address: c. Phone number: BY b. Phone number: 915 L1 V A 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)( a)7, Florida Statutes: a. Name and address: NJA.... ...... ......... ....... .--------------- ...................... --............._.........._........................_..._....-..._.._.._..._........._.._.............._._._....._... -- - .._._.....__.__._.._.. - b. Phone number: S. in addition to himself, owner designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1) b). Florida Statutes: a. Name and address: N/A b. Phone number 9. The expiration date of the notice of commencement is one (1) year from the date of recording unless a different date is specified WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Q y11mr rat- fOwr 0Here, Authorized OlTicer/Director/Partner/Manager Signatory's Title/Office STATE OF FLORIDA, COUNTY OF The foregoinginstrumentwas acknowiwdged before me this 3rd _ day of Augu-t-, 7.0 % % by (name of person) as Ow--(type_(type of authority: e.g., officer, trustee, attorney in fact) for - ................................. (name of party on behalf of whom instrument was executed), who is personally know to me or who has prod d _ FL DMV as identification. r Notary Pubk State of Flor'Ida :< nature of Notary Public JAMES C SMITH ° Verification Pursuant to Section 92.525, Florida Statutes Ex ires 211&* 0 RF 93M1 Under penalties of perjury, I declare that I have read the foregoing and ar> Expires 2/1rs/201aPP1Y. g' 9 that the facts stated in are true to the best of my knowledge and belief James Smith 4 8604 E Sligh Ave e of ural Person Signing Abov e ve Tampa FL 33610 DEPUTYCLERK 2017 LIMITED POWER OF ATTORNEY Altamonte Springs, Casselberry, Lake Mary, Longwood, Sanford, Seminole County, Winter Springs Date: 8/14/17 I hereby name and appoint an agent of: Blue Sky Solar James Smith Name of Company) to be my lawful attorney -in -fact to act for me to apply for, receipt for, sign for and do all things necessary to this appointment for (check only one option): IN The specific permit and application for work located at: 248 FAIRFIELD DR SANFORD FL 32771 Street Address) Expiration Date for This Limited Power of Attorney: 8/14/18 License Holder Name: Otto A. Curbelo State License Number: EC13004873 i Signature of License Holder: STATE OF FLORIDA COUNTY OF Hillsborough The foregoing instrument was acknowledged before me this 14tlday of August , 200 17 , by Otto Curbelo who is personally known to me or who has produced as identification and who did (did not) take an oath. PC& P'CGe ZZZ Signature Notary Seal) Patricia Nasrallah Print or type name Rev. 08.12) Notary Public - State of _ Commission No. My Commission Expires: PATRICIA A NASRALLAH MY COMMISSION # FF2431a2- ti;,• EXPIRES June 17, 2019 - 7 AQT);598-Ct55 Fk)MallotarySeMcexom