HomeMy WebLinkAbout2530 Little Gem Loop; 17-2482; HVAC (2)mat ` tom— 17 CITY OF SANFORD. BUILDING & FIRE PREVENTION PERMIT APPLICATION g Application No: 4 8 Documented Construction Value: S 116700 0 Job Address: 1';30 L I .T.F L C7/tq L_1,,&P Historic District: Yes No Eli Parcel ID:'"-71 _ -G j1 Residential Q Commercial Q Type of Work: New 0 Addition Alteration Repair Demo Change of Use Move Description of Work: e=,-t 77AG) . -S- i % t-tyAc- SV. 7,em t,v ki Plan Review Contact Person: f t i l t - yC>G-,w r Title: ;. rS,1;Itt q-i-1e :mac ' _ gsot.. Phone: Lkc'7 - ! - i Fax: ? z/ Email: 0e91,0-1)0741V Property Owner Information Name ;U ISM t . % I i. tx Phone: Street: 2 C 4-1 Z-E: ) E:-" L-EX)P Resident of property? izes City, State Zip: P- b 4:::`t- .327°7. Contractor Information Name AIR FLOW DESIGNS CENTRAL LLC Phone: 407-331-6521 Street: PO BOX.180308 - Fax: 407-831-2589 City, State Zip: CASSBI,RFRRY FT. 3271 g--0j()8 State License No.: CAC 1814423 Architect/Engineer Information Name: Street: City, St, Zip: Bonding Company: Address: Phone: Fax: E-mail: _ Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5" Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application -2) NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 711 The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current 1CC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. AV , o1/,7 Signature of Owner/Agent Date Signature of Co ranorlAgent Date Print Owner/Agent's Name Signature ofNotary-State of Florida Date Owner/ Agent is Personally Known to Me or Produced ID Type of ID CerrTT I3 Riird Print Contractor/Agent's Name Notary Public State of Florida Jenifer Caporuscio r--: pt My Commission FF 903796 of r,p Expires 0712712019 Contractor/ Agent is *-" Personally Known to Me or Produced ID X ype of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing Gas[] Roof Construction Type: Total Sq Ft of Bldg: Occupancy Use: Min. Occupancy Load: New Construction: Electric - # of Amps Flood Zone: of Stories: Plumbing - # of Fixtures Fire Sprinkler Permit: Yes No of Heads Fire Alarm Permit: Yes No APPROVALS: ZONING: UTILITIES: WASTE WATER: ENGINEERING: FIRE: BUILDING: COMMENTS: Revised: June 30, 2015 Permit Application N ct z Carrier a Distinguished HEATING & AIR CONDITIONING Dealer STATE CERTIFIED #CAC042721 P.O. Box 180308 • Casselberry, FL 32718-0308 Turn to the Experts Family Owned and Operated Since 1958 SYSTEM PROPOSAL Serving You and Your Neighbors!l www.farrtowuesigns. In rnone4or-tlJi-sbuu Proposal submitted ro: a 041 Homeawne'X ena, We Propose: To furnish, Install and service under warranty (stated below) products or related equipment for your home or business in accordance with the conditions and specifications set forth in this proposal. I sMAIOR'COMP,C?NENTaEQUIF'IUIENT>CONTROLS AND ELECTRICAL I @J' Heat Pump Air Conditioner Air Handier Furnace call Heat Strip Zoning BTUH Cooling: BTUH Heating: Mallet Modet: Modeh Model: Model: Model: Model: Nominal) SEER Rating: I g Nominat) HSPF: t -5-0AFUE: 80% Digital Heating/Cooling Thermostat e FW FV7 Day or 5/2 Day Programmable Thermostat: lt-`-' Humidity Control Thermostat: New Outdoor Breaker Amps ONew Indoor Breaker Amps New All Copper Electric Circuit for Outdoor Unit New All Copper Electric Circuit for Indoor Unit 0 New Outdoor Disconnect New Indoor Disconnect Upgrade Existing Electrical from Amps to Amps Other: lec Electronic Air Cfeaner Model #: EVAII Wort( Dane in Accordance with Existing Codes E3' II Req. Permits Pleated Media Filter Model #: U emove & Haul Away Exist' n Equi ent Regne Platform 1" Fiberglass Disp. or Washable Filter Filter Rack _x_ 0 stew Precast Concrete Par x New Platform Top Ultra Violet Light(s): 1-Bulb 2-Bulb All Work to be Performed in a eat and Professional Manner by Journey - Hepa Vac. Duct Cleaning # of Supplies: # of Returns: man Class Technicians. 5WI1 Debris Removed from Premises Daily. Other: - _ . - . Other, Modifications: Supply Plenum Retum Plenum: New Supply Grill(s) New Return Grills): IT Filterback Return Grill:? 'x_jL" Mastic on All Duct Joints Fiberglass Duct System with Reinforced Rip -Guard Vapor Barrier Main Trunk, Flexible Branch Supply and Return Ducts of Supplies: # of Re rns: IB Condensate Drain New LYExis tin wrap Refrigerant Copper Liquid Line: r11i d '" Refrigerant Copper Suction Line with insulation: r Condensate Pump: Dedicate edldreuit Combustion Air Vent(s): CO Detector Flex vent con.: Flex. Gas Line Con.: Ili' AFD 2nd Year Protection Plan U 1 Year Labor Warranty 121" Manufacturer's Warranty on compressor: 16 Years C, manufacturer's Warranty on Outdoor Coil: 74-5—Years E7 Manufacturer's Warranty on Indoor Coil: Years Manufacturer' s Warranty on Heat Exchanger: Years L! d Manufacturer's Warranty On All Remaining Parts: D Years 10 Year Mfg. Ext. Parts and Labor War. (Requires Annual Tune-up by AFD) Warranty on Duct installation: Years f Warranty - other: Years IKI Upon Receipt at our Office of Your Service Agreement We Will Provide a PRECISION TUNE-UP & PROFESSIONAL CLEANING at the End of the First Year, and ALL REPAIR LABOR for 2nd Year Is Also Covered Free of Charge. Unless otherwise noted, the scope of this job is confined to the details in the contract. Air Flow Designs will conduct a visual inspection of the homeowner's existing duct syste at the time of instatWtion and advise homeowner of any repairs necessary to achieve maximum performance from the new system and the cost for these repairs. It Is the Homeowner's Responsibility, with Air Flow Designs, to Arrange a Mechanical Inspection at Completion of Work. Init. Cont. Amt $ 1 rct!!n r» fh rts' S Y m.. r : vt.. I/J 1 I AFD Discount Net Contract g We propose to furnish complete, as specified above, for the sum of (tax includea): jj ea— is WbO-'6G } Payment to Installers in Full upon Completion of Installation. Make Check Payable to Air Flow Designs, Inc. BUYER' S RIGHTTO CANCEL- You, the Buyer. May Cancel This Transaction Without Penalty or Obligation Any Tune Prior to Midnight of the I Third Business Day after Me Date of This Transaction by Propter Notification. signature,, " X t _ _- ---~— This proposal is valid for SO days. It Is agreed and understood by the parties that all equipment and parts which are sold Signature, Date: pursuant hereto shall not become holures or part of the real estate where they ire rBwwn, d placed. Said parts and equipment shall at all times remain personal property and,ilur Ignature: Date: title thereto shill remain with the seller until payment In full is received. Buya hereby rc.—" agrees that all parts and equipment may be repossessed In the event of non-payment. ftleCopy - Homeowner /Customer yaflowcopy-Purchasing Pink Copy -File 512014 AHRI Certified Reference Number: 9677670 Date: 6/30/2017 Product: Split System: Heat Pump with Remote Outdoor Unit -Air -Source Outdoor Unit Model Number: 2SHCE430A*030* Indoor Unit Model Number: FX4DN(B,F)037L Manufacturer: CARRIER AIR CONDITIONING Trade/Brand name: CARRIER Series name: 14 SEER HP Manufacturer responsible for the rating of this system combination is CARRIER AIR CONDITIONING Rated as follows in accordance with AHRI Standard 2101240-2008 for Unitary Air -Conditioning and Air -Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): 29000 EER Rating (Cooling): '' 12.00 SEER Rating (Cooling): 15.00 Heating Capacity(Btuh) @ 47F: 27600 Region IV HSPF Rating (Heating): 8.20 Heating Capacity(Btuh) @ 17 F: 16700 Ratings followed by an asterisk (') indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valld only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and AMconfidentialreferencepurposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. AIR-CONDITIONING. HEATING, CERTIFICATE VERIFICATION REFRIGERATION INSTITUTE The information for the model cited on this certificate can be verified at www.ahrid lrectory.org, click on "Verify Certificate" link L make life better - and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above, and the Certificate No., which is listed at bottom right, 2014 Air -Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 131433115642863832 M Page 1 Residential Heat Loss and Heat Gain Calculation 6/30/2017 In accordance with ACCA Manual J Report Prepared By: Air Flow Designs For: marilyhn Rodriguez 2530 Little gem loop sanford, Florida 32771 Design Conditions: Orlando Indoor: Outdoor: Summer temperature: 77 Summer temperature: 95 Winter temperature: 70 Winter temperature: 38 Relative humidity: 55 Summer grains of moisture: 110 Daily temperature range:Medium Building Component Sensible Latent Total Total Gain Gain Heat Gain Heat Loss BTUH) BTUH) (BTUH) BTUH) Whole House 26,532 2,506 29,038 39,442 2.6tons) First Floor 26,532 2,506 29,038 39,442 All Rooms 26,532 2,506 29,038 39,442 Whole House 26,532 2,506 29,038 39,442 2.5 tons } HVAC-Calc Residential 4.0 by HVAC Computer Systems Ltd. 888 736-1101 Load calculations are estimates only. actual loads may vary due to weather and construction differences. 30/2017 SCPA Parcel View: 18-20-31-509-0000-1430 I Property Record Card tlavfOdcturaon,CFA Parcel: 18-20-31-509-0000-1430 Owner: RODRIGUEZ MARILYN & ISMAEL srusaou coirrrvrwr Property Address: 2530 LITTLE GEM LOOP SANFORD, FL 32773 N OY Y1,42 ME 144 Seminole County GIS Legal Description OT 143 AAGNOLIA CLUB 18 67 PGS 75 - 79 Value Summary 2017 Working 2016 Certified Values Values w Valuation Method Cost/Market Cost/Market Number of Buildings 1 1 Depreciated Bldg Value 106,455 94,033 Depreciated EXFT Value Land Value (Market) 25,500 21,000 Land Value Ag A101'Vfarket Value — 131,955 115,033 Portability Adj Save Our Homes Adj 0 51,017 Amendment 1 Adj P&G Adj 0 0 Assessed Value 131,955 64,016 Tax Amount without SOH: $1,493.00 i 2016 Tax Bill Amount $607.00 ; Tax Estimator 1 Save Our Homes Savings: $886,00 j Does NOT INCLUDE Non Ad Valorem Assessments Taxes i Taxing Authority T Assessment Value — Exempt Values -- — Taxable Value County Bonds 131,955 50,000 81,955 City Sanford 131,955 50,000 81,955 SJWM(Saint Johns Water Management) 131,955 50.000 I 81,955 County General Fund 131,955 s 50,000 81,955 Schools 131,955 '; 25,000 i 106,955 Sales Description Date (Book Page Amount Qualified Vac/imp I WARRANTY DEED 10/1/2016 08797 02 3 162.000 Yes Improved SPECIAL WARRANTY DEED 9/l/2008 07064 0715 135,000 No Improved WARRANTY DEED 9/1/2008 07078 1856 135,700 No Improved CERTIFICATE OF TITLE 2/112008 06936 1083 100 No Improved WARRANTY DEED 8/1/2006 06410 0576 226,000 : Yes Improved Find Comparable Sales Land Method Frontage Depth Units Units Price lLand Value LOT 1 25,500.00 25,500 Building Information a Bed/Bath count incorrect? Click Here. p://pareeldetaii.scpafl.org/ParcelDetailinfo,aspx?PID=18203150900001430 1/2 SCPA Parcel View: 18-20-31-509-0000-1430 Page 1 of 2 Property Record Card Da,Ifaaa,CFA q} Y,, Parcel: 18-20-31-509-0000-1430 Owner: RODRIGUEZ MARILYN & ISMAEL Property Address: 2530 LITTLE GEM LOOP SANFORD, FL 32773 Parcel Information Value Summary r18-- Parcel 18-20-31 509 0000 1430 2017 Working 2016 Certified Values Values Owner RODRIGUEZ MARILYN & ISMAEL Valuation Method Cost/Market Cost/Market Property Address 2530 LITTLE GEM LOOP SANFORD, FL 32773-- Number of Buildings 1 1 Mailing 2530 LITTLE GEM LP SANFORD, FL 32773 Depreciated Bldg Value 106,455 94,033 Subdivision Name MAGNOLIA CLUB Depreciated EXFT Value Tax District DOR Use Code St-SANFORD 0103-TOWNHOME 00-HOMESTEAD(2017) 2LandValue (Market) $25,500 Land Value Ag 21 000 Exemptions Just/Market Value " 131,955 115,033 Portability Adj Save Our Homes Adj $0 i $51,017 Amendment 1 Adj j j..._e_........_._....m.........__, __.._........_.. P&G Adj $0 $0 Assessed Value $131,955 $64,016 Tax Amount without SOH: $1,492.55 2016 Tax Bill Amount $607.06 Tax Estimator Save Our Homes Savings: $885.49 Does NOT INCLUDE Non Ad Valorem Assessments Legal Description LOT 143 MAGNOLIA CLUB PB 67 PGS 75 - 79 Taxes Taxing Authority Assessment Value I Exempt Values Taxable Value County General Fund 131,955 i 50,000 81,955 Schools 131,955 25 000 106 955 City Sanford 131,955 i 50,000 81,955 SJWM(Saint Johns Water Management) 131,955 50,000 { 81,955 County Bonds 131,955- 50,0001 81,955 Sales Description-- Date Book Paged Amount y Qualified Vac/Imp WARRANTY DEED 10/1/2016 08797 10233 i- 162 000 Yes Improved WARRANTY DEED 9/1/2008 07078 1856 135 700 No Improved SPECIAL WARRANTY DEED j 9/1/2008 07064 0715 135 000 No Improved CERTIFICATE OF TITLE 1 2/1/2008 06936 1083 100 No Improved WARRANTY DEED 8/1/2006 06410 0576 226,000 Yes Improved Fir;d Compatabts Sales__ Land Method _ Frontage Depth Units Units Price Land Value LOT 1 ', 25,500.00 ( 25,500 Building Information Description Year Built ve ( Fixtures I Bed I Bath ( Base Area Total SF Living SF Ext Wall Adj Value Repl Value I Appendages http://parceldetail.scpafl.org/ParcelDetailInfo.aspx?PID=l 8203150900001430 8/14/2017