HomeMy WebLinkAbout517 Myrtle Ave; 17-2821; WINDOW REPLACEMENTSEA'
CITY OF SANFORD
BUILDING & FIRE PREVENTION
PERMIT APPLICATION
Application No: / 9' d 4
Documented Construction Value: $ 000
Job Address: S rl Historic District: Yes,® No
Parcel ID: Residential Commercial
Type of Work: New Addition Alteration Repair Demo Change of Use Move
Description of Work: EQtJo\ 5 tXO DO-V8"w OCW
Plan Review Contact Person: Title:
Phone: 140-(- ZG5 - 'Zq 14 Fax: Email: V6 l (3gS It Q 0. 93 , (-a-I
Property Owner Information I -
Name rfA- ICE QELQ 6L'rY2S Phone: 4Cq— ZSCc - 2q (4-
Street: )V? y (L t Resident of property? : ES
City, State Zip: 5&M
Name
Street:
City, State Zip:
Name:
Street:
City, St, Zip: _
Contractor Information
Phone:
Fax:
State License No.:
Architect/Engineer Information
Phone:
Fax:
E-mail:
Bonding Company: Mortgage Lender:
Address: Address:
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF
COMMENCEMENT.
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction
in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools,
furnaces, boilers, heaters, tanks, and air conditioners, etc.
FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5" Edition (2014) Florida Building C ,
5
Revised: June 30, 2015 Permit Application
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be
found in the public records of this county, and there may be additional permits required from other governmental entities such as water
management districts, state agencies, or federal agencies.
Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713.
The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required
in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal.
The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in
accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value,
credit will be applied to your permit fees when the permit is issued.
OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will
be done ' liance with all applicable laws regulating construction and zoning.
1'y) C7 /z` // I
Signature of Owner Agent Date I Signature of Contractor/Agent Date
Owner/Agent is Personally KjwNkn to Me or
Produced ID Type of ID L_
e - evd S//7 Print
Contractor/Agent's Name Signature
of Notary -State of Florida Date Contractor/
Agent is Personally Known to Me or Produced
ID Type of ID BELOW
IS FOR OFFICE USE ONLY Permits
Required: Building Electrical Mechanical Plumbing[] Gas Roof Construction
Type: Total
Sq Ft of Bldg: Occupancy
Use: Min.
Occupancy Load: New
Construction: Electric - # of Amps Fire
Sprinkler Permit: Yes No # of Heads APPROVALS:
ZONING: c , 2-g OJT LITIES: Flood
Zone: of
Stories: Plumbing - #
of Fixtures Fire
Alarm Permit: Yes No WASTE
WATER: ENGINEERING:
FIRE: BUILDING: 'F t1-i6-t? Revised:
June 30, 2015 Permit Application
JWmnon, CFA
ps LscwatoouTV. a.ocmw
Parcel Information
PMPe[j . Record Card
Parcel: 25-19-30-5AG-0705-0100
Owner: MACPHEE JAMES W & GIBBS DENNY H
Property Address: 517 S MYRTLE AVE SANFORD, FL 32771
Parcel 25-19-30-5AG-0705-0100
Owner MACPHEE JAMES W & GIBBS DENNY H
Property Address 517 S MYRTLE AVE SANFORD, FL 32771
Mailing 517 S MYRTLE AVE SANFORD, FL 32771-1820
Subdivision Name SANFORD TOWN OF
Tax District S1-SANFORD
DOR Use Code 0102-SINGLE FAMILY - SANFORD HISTORICAL DISTRICT
Exemptions 00-HOMESTEAD(2000)
o
Legal Description
LOT 10 BILK 7 TR 5
TOWN OF SANFORD
PB 1 PG 59
Taxes
Taxing Authority
County General Fund
Schools
City Sanford
SJWM(Saint Johns Water Management)
County Bonds
Value Summary
2017 Working 12016 Certified
Values Values
Valuation Method Cost/Market Cost/Market
Number of Buildings 1 1
Depreciated Bldg Value 86,717 83,459
Depreciated EXFT Value 1,113 1,145
Land Value (Market) 19,380 15,390
Land Value Ag
Just/Market Value ** 107,210 99,994
Portability Adj
Save Our Homes Adj $32,812 $27,126
Amendment 1 Adj
P&G Adj $0 $0
Assessed Value $74,398 $72,868
Tax Amount without SOH: $1,191.09
2016 Tax Bill Amount $673.96
Tax Estimator
Save Our Homes Savings: $517.131TRIMNoticeHelp
Does NOT INCLUDE Non Ad Valorem Assessments
Seminole County GIS _3 irl
Assessment Value Exempt Values
74,398
74,398
74,398
74,398
74,398
Taxable Value
49,398 25,000
25,000 49,398
49,398 25,000
49,398 25,000
49,398 25,000
Sales
Description Date o Book Page Amount Qualified Vac/Imp
WARRANTY DEED
WARRANTY DEED
WARRANTY DEED
WARRANTY DEED
9/1/1999
5/1/1999
3/1/1995
4/1/1993
03731 1584
03664 1907
02898 0985
02573 0439
86,000
72,500
67,900
42,000
Yes
Yes
Yes
Yes
Improved
Improved
Improved
Improved
Land
Method Frontage Depth Units Units Price Land Value
FRONT FOOT & DEPTH 57.00 117.00 0 340.00 1 $19 380
Building Information
Is Bed/Bath count incorrect? Click Here.
http://parceldetaii.scpafl.org/ParcelDetailinfo.aspx?PID=2519305AGO7050100 9/20/17, 2:05 PM
Page 1 of 2
C I agree that, as the party legally and financially responsible for this proposed construction activity, I will
abide by all applicable laws and requirements that govern owner -builders as well as employers. I also
n understand that the construction must comply with all applicable laws, ordinances, building codes, and
zoning regulations.
I am of aware of construction practices and I have access to the Florida Building Codes.
I understand that I may obtain more information regarding my obligations as an employer from the Internal
Revenue Service, the United States Small Business Administration, the Florida Department of Financial
Services, and the Florida Department of Revenue. I also understand that I may contact the Florida
Construction Industry Licensing Board at 1-850-487-1395 or at www.myflorida.com/dbpr/pro/cilb/ for
more information about licensed contractors.
I am aware of, and consent to, an owner -builder building permit applied for in my name and understand
that I am the party legally and financially responsible for the proposed construction activity at the address
listed below.
I agree to notify the building department immediately of any additions, deletions, or changes to any of the
information that I have provided on this disclosure or in the permit application package.
Licensed contractors are regulated by laws designed to protect the public. If you contract with a person
who does not have a license, the Construction Industry Licensing Board, the Department of Business and
Professional Regulation and the building department may be unable to assist you with any financial loss
that you sustain as a result of a complaint. Your only remedy against an unlicensed contractor may be in
civil court. It is also important for you to understand that, if an unlicensed contractor or employee of an
individual or firm is injured while working on your property, you may be held liable for damages. If you
obtain an owner -builder permit and wish to hire a licensed contractor, you will be responsible for verifying
whether the contractor is property licensed and the status of the contractor's workers' compensation
coverage.
Property Address: 1 7 i. S 0yr2-R_C A JE
I, 7 1-y t s do hereby state that I am qualified
and capable of performing the requested construction involved with the permit application filed and agree to the
conditions specified above.
Signature of Owner -Builder
Form of Identification
Must be Photo ID)
Date
A violation of this exemption is a misdemeanor of the first degree punishable by a term of imprisonment
not exceeding 1 year and a $1,000.00 fine in addition to any civil penalties. In addition, the local
permitting jurisdiction shall withhold final approval, revoke the permit, or pursue any action or remedy
for unlicensed activity against the owner and any person performing work that requires licensure under
the permit issued.
Rev. 9.14.2009
C
OWNER BUILDER STATEMENT/AFFIDAVIT
Altamonte Springs, Casselberry, Lake Mary, Longwood, Oviedo, Sanford,
Seminole County, Winter Springs
Florida Statutes are quoted here in part for your information to indicate the authority for exemptions for
homeowners from qualifying as contractors and to express any applicable restrictions and responsibilities.
OWNERS MUST PERSONALLY APPEAR AT THE BUILDING DIVISION TO SIGN THIS DOCUMENT
BY SIGNING THIS STATEMENT, I ATTEST THAT: (Initial to the left of each statement)
I understand that state law requires construction to be done by a licensed contractor and have applied for
an owner -builder permit under an exemption from the law. The exemption specifies that I, as the owner of
the property listed, may act as my own contractor with certain restrictions even though I do not have a
license.
I understand that building permits are not required to be signed by a property owner unless he or she is
responsible for the construction and is not hiring a licensed contractor to assume responsibility.
I understand that, as an owner -builder, I am the responsible party of record on a permit. I understand that I
may protect myself from potential financial risk by hiring a licensed contractor and having the permit filed
in his or her name instead of my own name. I also understand that a contractor is required by law to be
licensed in Florida and to list his or her license numbers on all permit and contracts.
I understand that I may build or improve a one -family or two-family residence or a farm outbuilding. I
may also build or improve a commercial building if the costs do not exceed $75,000. The building or
O
residence must be for my own use or occupancy. It may not be built or substantially improved for sale or
lease. If a building or residence that I have built or substantially improved myself is sold or leased within
in 1 year after the construction is complete, the law will presume that I built or substantially improved it
for sale or lease, which violates this exemption.
I understand that, as the owner -builder, I must provide direct, onsite supervision of the construction.
I understand that I may not hire an unlicensed individual person to act as my contractor or to supervise
persons working on my building or residence. It is my responsibility to ensure that the persons whom I
employ have the licenses required by law and by city ordinance.
I understand that it is a frequent practice of unlicensed persons to have the property owner obtain an
owner -builder permit that erroneously implies that the property owner is providing his or her own labor
and materials. I, as an owner -builder, may be held liable and subjected to serious financial risk for any
injuries sustained by an unlicensed person or his or her employees while working on my property. My
homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an owner -
builder and am aware of the limits of my insurance coverage for injuries to workers on my property.
I understand that I may not delegate the responsibility for supervising work to a licensed contractor who is
not licensed to perform the work being done. Any person working on my building who Is not licensed
must work under my direct supervision and must be employed by me, which means that I must
comply with laws requiring the withholding of federal income tax and social security contributions
under the Federal Insurance Contributions Act (FICA) and must provide workers' compensation
for the employee. I understand that my failure to follow these laws may subject me to serious financial
risk.
Rev. 9.14.2009
Revision City of Sanford
Response to comments 1l1 Lol Building & Fire Prevention Division I
Z . Ph: 407.688.5150 Fax: 407.688.5152 Email:
building@sanfordfl.gov Permit -
vM a 1 Project
Address: M w Contact:.
Ph:
Submittal
Date. OUA.-
f— Fax:
Email:
Q 1 Trades
encompassed in revision: General description of revision: Building
Plumbing
Electrical
Mechanical
Waste
Water ROUTING
INFORMATION Department
Approvals Utilities
Waste
Water Planning
Engineering
Fire
Prevention Building
0M
FIRE DEPARTMENT
PLAN REVIEW COMMENTS
Building & Fire Prevention Division
Application Number: 17-2821 Date: 10/05/2017
Project Description: Windows/Siding Contact Name: Denny Gibbs
Job Address: 517 S Myrtle Ave Contact Email: DGibbsl(&lI.rr.com
This is a general overview for code compliance in accordance with the minimum plan review required by the Florida Building Code. It is not a
complete detailed review. The comments noted in this review must be addressed before the plans can be approved. Changes to plans shall be
submitted on the same size format as the original submittal — changes in letter form are not permitted. All references to FBC Chapter 1 are as
amended by City of Sanford ordinance viewable on our website at www.sanfordfl.gov. Provide two copies of affected plan sheets and/or
supplemental information as requested. Permit submittals will not be accepted without two copies.
COMMENTS:
1. The permit application description of work states "remove old window and replace with new jeld-wen windows (2)". The
Certificate of Appropriateness grants approval to "place windows on east elevation and decrease the size of the window opening.
Further clarification is required as to the exact scope of work that will be conducted at this property.
If you are simply swapping out windows, size for size (meaning no openings are being modified), then the only requirement needed to
achieve a plan review approval is two copies of a floor plan showing the exterior walls and the location and size of the windows being
replaced. This floor plan can be hand -drawn.
If you are modifying a window opening, signed and sealed engineering from a design professional will be required as this is
considered a structural modification. The engineering must include all framing requirements needed to modify the opening. In
addition, a floor plan will also be required showing the location of the window replacements and modification.
FBC 107
2. The permit application description of work also states to replace bad siding. Please provide an exterior wall floor plan (same as
above) showing the location of the siding replacement.
FBC 107
No Review has been conducted*
Any error or omission in this plan review shall not be construed to grant approval of any violation of any of the adopted codes or municipal
ordinances of this jurisdiction.
Office meetings with the plans examiner to discuss comments will require an appointment, arranged by phone or email prior to arrival.
Respectfully,
Steve Fiorey, CBO
Residential Plans Examiner
M!
RC Engineering, LLC
Residential, Commercial, Multi -Family Consulting Engineering
2381 Crest Ridge Ct November 14, 2017
Sanford, FL 32771
407-474-9181
Fax 407-328-5397 City of Sanford Building Department
300 North Park Ave
Sanford, Florida 32771
Re: Gibbs Residence
517 So. Myrtle Ave
Dear Building Official:
The following responses address your comments from review letter dated 10/5/17.
1) See attached engineered plan showing location and size of window replacement.
See plan's scope of work
The new windows will require larger openings, see plan.
Plans are signed and sealed for new window openings.
2) See plan for window installation, siding replacement and floor plan.
The Jeld Wen Window installation instructions has been included (FL. Approval
17594.4).
Please call Jack Reynolds at 407-262-9176 or me at 474-9181 if you have any questions.
Sincere
4
Dd#
A@
e
i4/$ooRoo e i
a
s
a!,5 ,
LPL nse #:5K590 a
9 STATE OF%
0OOOOD0000 'k
gip J
RC Engineering, LLC
407-474-9181
FAX 407-688-1898
City of Sanford
r 5
Historic Submittal Guidelines
F U Window & Door Replacement
The following information is meant as a general guideline to assist with meeting Florida
Building Code and Historic Preservation requirements when replacing or altering windows
or doors on a home or business located in the Sanford Historic District.
GENERAL RULES FOR HISTORIC PRESERVATION COMPLIANCE
A Certificate of Appropriateness must be applied for prior to obtaining a Building Permit
FLORIDA BUILDING CODE COMPLIANCE
If Florida Product Approval cannot be obtained due to the proposed window or door being custom made
or refurbished, the following alternative method is required:
A product -evaluation report or certification based upon testing or comparative or rational analysis, or a
combination thereof, developed and signed and sealed by a Florida professional engineer or Florida
registered architect, which indicates that the product complies with the code.
553.8425(1)(d) Florida Statute
The following information must be included on the submittal from the engineer or architect:
Detailed and dimensioned drawing of the window or door
Installation requirements for the window or door (type and size of fasteners, spacing of fasteners)
Substrate of existing structure where window or door will be installed
Maximum design pressure (positive & negative) of the window or door
Signed and sealed
The following statement must also be provided by the engineer or architect:
The (window/door) has been designed to meet ultimate wind speed of 139mph and complies with
current Florida Building Code requirements."
Revised: September 2016
REQUIRED INSPECTION SEQUENCE
Address:
OUILIDING (PERMIT
Min Max .. Inspection Description
Footer / Setback
Stemwall
Foundation / Form Board Survey
Slab / Mono Slab Prepour
Lintel / Tie Beam / Fill / Down Cell
Sheathing — Walls
Sheathing — Roof
Roof Dry In
Frame
p Insulation Rough In
Firewall Screw Pattern
Drywall / Sheetrock
Lath Inspection
Final Solar
Final Firewall
Final Roof
Final Stucco / Siding
Insulation Final
Final Utility Building
Final Door
Zo 3o Final Window
Final Screen Room
Final Pool Screen Enclosure
Final Single Family Residence
Final Building (Other)
Min Max Ins ection Descri Lion
Electric Underground
Footer / Slab Steel Bond
Electric Rough
T.U.G.
Pre -Power Final
Electric Final
1, t . 1 v. tM
X 1 •/;{
C
at.:y n.r.. 1.ax;,s ys,y_l v{,i9';a[/+H^ m q `.i
f ,
T.4Kl'.blG M ?pV' i• _ 'Y:'??.,r`. °'
Min Max Inspection Descri Lion
Plumbing Underground
Plumbing Sewer
Plumbing Tub Set
Plumbing Final
e
Inspection Description
Mechanical Rough
i ..:$ (
p•
i...ylllrvw,1,;'41.
j a•. t
i 5 j7j'i; Tx«7«.
P f"vYe. [iAt G" l_ n .N 5 PK 30 [Z rc r i £i °:" 1 n^fi ' (i':,. y :v 1 C r .. ,..>. j1 ,:ry£. 7 i•'v (i•7 :r• r;'i„ ..f•G ram'•.4,`if:l,
L^s;,.n'1 1:_t'.a"+riC,7/?fLi.IL•...1 t iC, 3.5:sT.:..7f3._.u.S fn.o.'+..1.:.._c•ti
msecfion _ _ . . 4110-
REVISED:
June 2014
r-- KITCHEN
l
r-
DECK i
EMOVE (3)WINDOWS
ND INSTALL (2)
EW WINDOWS LAUNDRY
ROOM
BATHROOM —
HISTORIC PERMIT
All work must be done in strict accordance with the
Approved Certificate of Appropriateness
wilding does not approve any work outside this scope
permit Applicant is coley responsible for compliance
RECORD COPY
LIVING ROOM
DINING ROOM
1,200 S.F. HOUSE
FRONT PORCH 130' CLO ETS `
r— I
III
OFFICE
BEDROOM II
II
ATHROOM
40'-0"
EXISTING HOUSE FLOOR PLAN
Irn,,_ A"=1 '
SANFORD BU11 DING DIVISION I " --- II ;II; Iil; ;I-1---7 SAPS
I; ;II I I; ;IPERMITISSUEDSHALLBECONSTRUEDTOBE
1 _
I 1II1 _ _ III
I _
I
1
ENSE
TO PROCEED WITH THE WORK AND NOTL _ JL _ _ JL _ J AUTHORITY
TO VIOLATE, CANCEL, ALTER OR SET SIDE
ANY OF THE PROVISIONS OF THE TECHNIC DES,
NOR SHALL ISSUANCE OF A PERMIT PREVE NT THE
BUILDING OFFICIAL FROM THEREAFTER _ _ L 1 - -LL -JA CORRECTION
IN PLANS, OF CONSTRUCTIONEQUIRINGORVIOLATIONSOFTHISCODE— EXISTING REAR
ELEVATION & DEMO PLAN i„=1
EXISTING SIDING
TO BE REPLAC IN COMPLIANCE
WITH CAO EWED POR
CODE COMPLIANCE PLANS EXAMINER
Ix-k(
e-I 1 F,F ;TF_, DATE IIII
IIII
li ill
i i Ili ill i
i Ili IL II
L___ IILJ NEW 1x6
SIDING (EXTENT TO BE DETERMINED
IN FIELD) & COMPLIANCE WITH
GAO PROPOSED PLAN
1 3036
WINDOWS
SIDING TO
REMAIN ROOF & WALL
SHEATHING NAILING PATTERN 8D (RING
SHANK) NAILS 8" O/C IN FIELD 8D (RING
SHANK) NAILS 4" O/C EDGE 1-/2I
SHEATHING W/1
x6 SIDING L_ — _ _ — — EXIST.
BOT. - ---
PLATE 1
PROP. DBL.
2x12 HDR.
PROP. WINDOW
PROP. SILL
I d-
H2.
5
CLIP EA. NEW STUD TO
PLATE 2) HDR.
STUDS & (1) FULL LENGTH STUD
EA. SIDE OF OPENING FXLSLF)B1_-
IOP_P-1 TF --- RETA I
STII[ S OR,IREFRXI I I PROP. DBL.
12x12 HEADER M ')LSTA
12 PER HHSIDE & CENTER\ FRAME OPENING
FOR NEW
WINDOW n AME
OPENING
R NEW
WINDOV I. EXIST. [
1
PLATE BOT. ---JJ _____
1111------ 11______1 ___ill1.11_____]1______ Ill EXIST. BOTTOM
PLAT PROP. 2x4
STUDS H3 CLIP EA. NEW 2 SPF,
16"O/C STUD TO PLATE PROPOSED WALL
SECTIONS DEMO SCOPE
OF WORK 1) REMOVE (
3) EXISTING WINDOWS AND TRIM 2) REMOVE
1x6 SIDING AND SHEATHING ABOVE AND BELOW WINDOW OPENING. HOMEOWNER TO
DETERMINE EXTENT OF SIDING REMOVAL 3) REMOVE
ANY ROTTEN 2x4 STUDS, SHEATHING AND SIDING PROPOSED CONSTRUCTION
SCOPE OF WORK F-03
I
i
I
I
I
I
I
I
I
I
I
I
I
I
I
I
II
I
I
I
I
I
I
I
I
I
I
1)
FRAME
IN NEW OPENING TO ACCOMONDATE (2) NEW 3036 WINDOWS INSTALL WINDOWS
PER MANUFACTURERS SPECS. 2) ADD
STUDS AS NECESSARY. ALL NEW STUDS TO BE #2 SPF, 16" 0/C. ALL NEW
STUDS TO BE CLIPPED TO EXISTING TOP AND BOTTOM PLATES 3) ADD
NEW DBL. 2x12 HEADER OVER NEW WINDOW OPENING. USE (2) HEADER STUDS AND
ONE FULL LENGTH STUD EACH SIDE OF NEW OPENING. STRAP HEADER TO
STUDS W/(2) LSTA 12 EACH SIDE 4) ADD
NEW 1 /2" CDX PLYWOOD SHEATHING AND TYVEK OR 1 /2" GREEN BOARD ZIP SYSTEM)
W/O TYVEK. 5) ADD
NEW 1x6 SIDING TO MATCH EXISTINGCAULK AND PAINT. EIV e WIND
LOAD
NOTE
I 0 ,.° a` NOV
1
5 2017 THIS STRUCTURE HAS
BEEN DESIGNED TO MEET OR EXCEED
THE 140 M.P.H.(Vult) WIND wM LOAD REQUIREMENTS OF
CHPT. 3 OF THE 2014 ERMOCRATS,CASffLLO, P.E. DATE FLORIDA RESIDENTIAL BLDG. CODE,
5th ED. FL. REG. # 52590 o E 8 Z
0
E
Fr
E
FT oHLLrn
E
QCO
c7 o0 J
toF LU
Ujo0v
U = p 0
d' a.
N ~
J M Q
H LL
W 8 U Z Q
tl
Z
Q
W
M
to
moo Q OJZo
Z="
Z
F- WOE O
000 0
0
z z rj)
w
Z
E
U.
a
DESIGNED:
JHR
I
REVIEWED
BY: RC SCALE:
1 /4"=1'
DATE: 11 /12/17
Al 1 OF 1.
VL # 1-15g4.4
4" MAX.
16" O.C. MAX. FROM
THRU FRAME CORNERS
1 1
H F
H F
H (r
I WINDOW WIDTH
45.375" MAX.)
16" O.C.
MAX. TYe 9THRUit
FRAME 1 C6
yR
I
Tog,'
Is
Rai
b g
co
TYPICAL ELEVATION WITH FASTENER SPACING
MIN. DISTANCE FROM
EDGE: 3/4"
1 2X WOOD FRAME
2 1 1/4" MIN.
EMBEDMENT
4" MAXSHIMSPACE
CLAD FRAME SECTION (TYP)
TF'rIl' VERTICAL SECTION
Installed Fastener Schedule:
1. Seal flange/frame to substrate.
2. All windows: install corrosion resistant #8 fasteners no more than 4" from each corner and 16" o.c. through
the nail fins on all sides of the window. Fasteners must be long enough to penetrate at least 1 1/4" into
framing members.
a 0 0
This schedule addresses only the fasteners required to anchor the
window to achieve the rated design pressure up to the size limitations
noted. It is not intended as a guide to the installation process and does
not address the sealing consideration that may arise in different wall
conditions. For the complete installation procedure, see the instructions
packaged with the door or go to
www.jeld-wen.com/resources/installation.
DISCLAIMER:
This drawing and its contents are confidential and are not to be
reproduced or copied in whole or in part or used or disclosed to others
except as authorized by JELD-WEN Inc.
MAXISPACE
2X WOOD FRAME
THROUGH FRAME
INSTALLATION
1 1/4" MIN. 1/4" MAX
EMBEDMENT SHIM SPACE
2X WOOD
FRAME
2
MIN. DISTANCE
FROM EDGE: 3/4"
FRAME JAMB SECTION (TYP)
1 HORIZONTAL SECTION
Frame oo„s"Max DP Ratin Impact
45 3 8" x 92" 35 NO
General Notes:
1. The product shown herein is designed, tested and manufactured to comply with the wind load criteria of
the adopted International Building Code (IBC), the International Residential Code (IRC), the Florida
Building Code (FBC) and the industry standard requirement for the stated conditions.
2. Buck, framing and masonry by others and is responsibility of architect or engineer of record.
3. All glazing shall conform to ASTM E1300.
4. At minimum, glazing shall be double strength annealed insulating glass.
ROJECi ENGINEER: DATE:
01/19/2015 3737 Lakeport Blvd
RAWN BY: SCALE: JEL&WENKIamath Falls, OR. 97601
D. Vezo NTS Phone: (541) 882-3451
Jones
Siteline Wood Double Hung Window
PDbP1204b
IDENTIFIER Na. PLANT NAME AND LCIG4TION:
N/A Rantoul, IL
This Instrument Prepared By
Lonnie N. Groot, Esquire
Stenstrom, McIntosh, Colbert,
Whigham, P.A.
1001 Heathrow Park Lane, Suite 4001
Lake Mary, Florida 32746
Return To:
Ms. Christine Dalton
Community Planner/Historic Preservation Officer
Planning and Development Services Department
City Hall
300 North Park Avenue
Sanford, Florida 32771
Tax Parcel Identification Number: 25-19-30-5AG-0705=0100.
s ssss ,ss ssae_< n;sss s,s s s `i is.s a
lD i11 17 1 M. O i O l i'II FL.,fUMPT
EM" PC
CLERK'S `1 201 7075400
1
Irla.0F, I -
HISTORIC PERMIT theAllworkmustbedoneinstrictaccordance
Approved Certificate of Appropriateness
Building does not approve any work outside this scopePemtitApplicantissoleyresponsibleforcompliance
HISTORIC PRESERVATION BOARD OF THE CITY OF SANFORD DEVELOPMENT
ORDER RELATING TO 51.7 SOUTH MYRTLE AVENUE AND ISSUING
CERTIFICATE OF APPROPRIATENESS
On June 21, 2017, the Historic Preservation Board of the City of Sanford issued
this Development Order issuing a Certificate of Appropriateness relating to and
touching and- concerning the following described property: 517 South Myrtle Avenue,
Seminole County Tax Parcel Identification Number: 25-19-30-5AG-0705-0100.
FINDINGS OF FACT
Property Owners: James W. Macphee and Denny H. Gibbs
517 South Myrtle Avenue
Sanford, Florida 32771
Applicant: Denny H. Gibbs
517 South Myrtle Avenue
Sanford, Florida 32771
Project: To place windows on east elevation and decrease the size
of the, window opening on the real property located at 517
South Myrtle Avenue. -
Requested Development Approval: To place windows on east elevation and
decrease the size of the window opening on the real property located at 517 South
Myrtle Avenue. -
J LDING
Additional Findings: None.
OFPAR-
HISTORIC PERMIT
All work must be done in strict accordance with the
Approved Certificate of AppropriatenessCONCLUSIONSOFLildingdoesnotapproveanyworkoutsidethis scope
Permit Applicant is soley responsible for compliance
a). Under Schedule "S" of the. City's Land Development Regulations as set
forth in the Code of Ordinances of the City of Sanford, windows, frames, glass, muntins,
mullions, sills, lintels and pediments in good condition or repairable and in character
with the style and period of the building shall be retained. Window types that are no
longer permitted by law, such as jalousies, may be replaced with another style of
window that is in character with the style and period of the building. (S-33). The existing
windows are not original and are not in character with the period of the building. If
windows or window details are determined to be irreparable, they may be replaced
provided that on the primary facades of contributing buildings, replacement windows
shall match .the existing original windows in size; configuration, material, design and
placement. A window survey and specifications for each window must be submitted
with the Certificate of Appropriateness application. On secondary facades, replacement
windows may be of a different design or type provided the windows are consistent with
the style of the building. (S-33). The proposed windows are consistent with the style of
the building. Only when a change is .appropriate to the style and period of the building
may a window be relocated,, enlarged, reduced or introduced. (S-33). The reduction of
the window opening is appropriate to the style and period of the building. When
replacing existing windows that are inappropriate to the style and period of the building,
they shall be replaced with new windows that are appropriate to the style and period of
the building. (S-33). The proposed windows are appropriate to the style and period of
the building. Windows on additions shall have the same orientation and be of a similar
size to the existing or original windows of the principal fagade except if the addition is
HISTORIC PERMIT
All work must be done in strict accordance witl
Approved Certificate of Appropriatettoss
Building does not approve any work outside this
on the same plane as the existing principal fagade, then the wind8 ik dk4en rdditilDtVsponsibteforcompli
shall match the original windows in orientation, size, materials and configuration. (S-33).
The proposed windows are similar to the original windows in orientation, size, materials
and configuration. Windows shall be proportioned such that the height shall be equal to
or greater than the width, with the exception of historically, appropriate window
groupings. (S-34).The proposed windows are in a historically appropriate grouping.
b). The purpose and intent of Schedule "S" have been met in the context of
the approval set forth herein.
c). To the extent that a conclusion of law as set forth herein also constitutes a
factual finding, then such shall be taken to be so as part of this Development Order
d). The proposed Certificate of Appropriateness is hereby found and
determined to comply with the aforestated requirements.
e). Additionally, the Certificate of Appropriateness sought is hereby found and
determined to be consistent with the City of Sanford Comprehensive Plan and
development of the property as proposed would be consistent with and in compliance to
applicable land development regulations and all other applicable regulations and
ordinances as set forth in the Code of Ordinances. of the City of Sanford.
A0
NOW, THEREFORE, IT IS ORDERED THAT:
1). The aforementioned application for a Certificate of Appropriateness is
APPROVED.
2). Development shall occur in accordance with the provisions of Schedule
S" of the City's Land Development Regulations as set forth in the Code of Ordinances
3
of the City of Sanford.
HISTORIC PERMIT
All work must be done in strict accordance with the
Approved Certificate of Appropriateness
Building does not approve any work outside this scope
Permit Applicant is soley responsible for compliance
3). This Development Order touches and concerns the aforedescribed
subject real property and shall be a burden that runs with and burdens the subject real
property and all matters set forth herein may be enforced by any code enforcement
process available to the City.
Done and Ordered on the date first written above.
As approved and authorized for execution by the Historic Preservation Board of
the City of Sanford at its meeting of June 21, 20.17.
ATTEST.'' . alpB' G HISTORIC PRESERVATION BOARD
OF THE CITY OF SANFORD
yl
ry .-
f ' f Tam A ni , Chai anCynisPorter, City C lrk F y 9
Date: 1g -1 i City
Seal ' n F
r' -- Nunc pro tunc to June 21, 2017. Witness:
Jennifer
Go way PROPERTY
OWNERS SIGNATURE BLOCK FOLLOWS:
HISTORIC PERMIT
All worts must be done in strict accordance with the
Approved Certificate of Appropriateness
Building does not approve any want outside this scope
Permit
Y PROPERTYY WN for cot tiatece
JOINDER AND APPROVAL OF CONDITIONS BY P
IN WITNESS WHEREOF, the subject Property Owner has signed and sealed
these presents, through its authorized officer and representative, the day and year
written below and AGREES to all of the terms and conditions of this Development
Order approving a Certificate of Appropriateness.
ATTEST.' JAMES W. MACPHEE AND DENNY H.
GIBBS
STATE OF FLORIDA )
COUNTY OF SEMINOLE
The foregoing was sworn to and subscribed before me this2lLday of June, A.D.
2017, by James W. Macphee and Denny H. Gibbs, who are personally known to me or
who produced A.9n identification.
WITNESS my hand and official seal in the C my and State aforesaid this Z-w
day of June, A.D. 2017.
JENNIFER M. GOLLOWAY
Notary Public - State of Florida
My Comm. Expires Nov 3, 2017
Commission FF 043230
N ota ry P l is Nglor`il Norte' Assn.
My Commission Expires:
5
fiilS INSTRUMENT PREPARED BY:
Address:
NOTICE OF COMMENCEMENT GRANT MALOYf SEMINOLE COUNTY - CLERK OF CIRCUIT COURT t, COMPTROLLER
State of Flori BK 9031Ps 452 (1 P3 S ) County
of emin/ol e ,c a ?i1 7 Permit
Nu ber: I L ( rcel ID Number: B ev w_- o
i5 FG to
certain real property; The
undersig d hereby gives notice provement will be made and in accoraalt owing
information is provided in this Notice of Commencement. Chapter713, Flo g ' . ••• -. 4; nESCRIPTION
OF PROPERTY: (Legal de rip of the property and street address if available)n DESCRIPTION
OF OWNER
INFOEMATION: ' p Name:
Address:
Fee
Simple Title Holder (if other than owner) Name: Address:
CONTRACTOR: /
Name:
Address:
Persons
within the State of Florida Designated by Owner upon whom notice or other documents may be served as
provided by Section 713.13(1)(b), Florida Statutes. Name:
Address:
of In
addition to himself, Owner Designates To
receive a copy of the Lienor's Notice as Provided in Section
713.130)(b), Florida Statutes. Expiration
Date of Notice of Commencement (The expiration date is 1 year from date of recording unless a different
date is specified) WARNING
TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENTARECONSIDEREDIMPROPERPAYMENTSUNDERCHAPTER713, PART 1, SECTION 713.13, FLORIDASTATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICEOFCOMMENCEMENTMUSTBERECORDEDANDPOSTEDONTHEJOBSITEBEFORETHEFIRSTINSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORECOMMENCINGWORKORRECORDINGYOURNOTICEOFCOMMENCEMENT. Under
enalties of perjury, I declare that I have read the foregoing and that the facts stated in it are true tot
a best f my knowledge and belief. S Owners
Signature Owner'
s Pnmed Name 1 The
owner must sign the notice of commencement and no one else may be permitted to sign in his or her stead' FloridaStatute713.13(1)(g): - ''0 1yM
State
of _ County of t z The
foregoing instrument was acknowledged before me this 6 day of l e m i . Ile-
20
1 ' o w by
U I Who is personally known to me m w Q i Name
of person making statem t 7 " m
OR
who has produced identification type of identification produced: 1, q cn y
w. C,
0 arrr4q,
k
s" "s••, ANNETTE BLAND °' c = 0
Notary
Public - State of FloridaUo w n Commission # GG
060623 Notary Signature W oafs My