HomeMy WebLinkAbout3653 Orlando Dr (4)PERMIT ADDRESS CONTRACTOR ADDRESS PHONE NUMBER PROPERTY OWNER ADDRESS -k 2- ELECTRICAL CONTRACTO] MECHANICAL CONTRACT( PLUMBING CONTRACTOR MISCELLANEOUS CONTRACTOR SUBDIVISION PERMIT # — 9C ' DATE PERMIT DESCRIPTION n&V ''- PERMIT VALUATION SQUARE FOOTAGE / I� ty U txj En En rNo 0 d �-3 CITY OF SANFORD,• FLORIDA APPLICATION FOR BUILDING PERMIT PERMIT ADDRE'--36 ' Orlando Drive PERMIT NUMBER ®i 7 Total Contract Price of Job $4,950,000 Total Sq. Ft,103,141 Describe work 103,141sf expansion to existing Wal-Mart retail store. Type of Construction Type IV Flood Prone (YES) Number of Stories 1 Number of Dwellings N/A ZoningGC2 Occupancy: Residential Commercial X Industrial LEGAL DESCRIPTION (please attach printout from Seminole County) TAX I.D. NUMBER 11-20-30-300-035C-0000 OWNER Wal-Mart Stores East, Inc. PHONE NUMBER (501)204-0489 ADDRESS 702 SW 8th Street CITY Bentonville STATE AR ZIP 72716 TITLE HOLDER (IF OTHER THAN OWNER) ADDRESS CITY BONDING COMPANY ADDRESS CITY STATE STATE ZIP ZIP ARCHITECT Raymond H. Harris Architect ADDRESS 211 N. Record Street, Suite 222 CITY Dallas STATE TX ZIP 75202 MORTGAGE LENDER ADDRESS CITY STATE �— ZIP CONTRACTOR /l7Pf �J L (PHONE NUMBER ADDRESS J GI e ST. LICENSE NUMBER _ i0 CITY STATE ✓ ZIP Application is hereby made to obtain a permit to do the work and installations as indicated: I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL, PLUMBING, MECHANICAL, SIGNS, POOLS, ETC. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating Construction i and zoning. A COPY OF THE RECORDED COPY OF THE NOTICE OF COMMENCEMENT WILL BE POSTED ON THE JOB SITE WITH PERMITS NO LATER THAN SEVEN (7) DAYS AFTER THE PERMIT HAS BEEN ISSUED. FAILURE TO RECORD A NOTICE OF COMMENCEMENT -MAY RESULT IN YOU PAYING TWICE FOR THE IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. F U 0 b 0 �4 a Z 0 NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. ACCEPTANCE OF PERMIT IS VERIFICATION THAT I WILL NOTIFY E OWNER OF THE PROPERTY OF THE REQUIREMENT OF FLORIDA LIEN LAW, FS713. ************** *** ** *** ********************* ******************************* y ro Z °� pO to L o N Signature of Owner/Agent & Date Signature f Contractor & Date °,a ; En Type or Print Owner/Agent Name d� T or Print C ractor's Name t7 � x c z cu a 3 - 0 E x M Q Z r-i H N H (0 W r. 0 o b rn N 4J �4 a 0 0 >4 Z w H 01 Sig atu e of Notary & Date ( ficial Seal) rt Mary L: Muse 0 v '� ��;• CommCC 851 / ;ir n A � �,e4�tl <� 4 h Cl •'• F and ru -ro (1 Atlantic Bonding Co., Inc. - - - - - - - - - - - �O ?- Application Approved BY_ i 4 i Date: '/ 1 7—( FEES: Building Radon Police Eire Open Space Road Impact Application PERMIT VALIDATION: CHECK CASHDATE BY ORIGINAL (BUILDING) YELLOW (CUSTOMER) PINK (COUNTY TAX OFFICE) GOLD (CO. ADMIN) **** THIS APPLICATION USED FOR WORK VALUED $2500.00 OR MORE 4 Signature of Notary'/& Date " NOTARY SEAL" Charlene E. Lyon, Notary Public Benton County, State of Arkansas My Cbmmissioli Expires 3J1/2004 CITY OF SANFORD PLUMBING PERMIT APPLICATION Permit Number:y l •- 9ou Date:_ I o 1 The undersigned hereby applies for a permit to install the following plumbing: Owner's Name: l,Jc,.1—Mc rb Address of Job: Plumbing Contractor: Residential: Non -Residential: Number Amount Addition, Alteration, Repair (Residential & Non -Residential) New Residential: One Water Closet Additional Water Closet Commercial: Minimum Permit Fee $25.00 Fixtures, Floor Drain, Trap 0 Sewer Piping Water Piping I Gas Piping Manufactured Building Description of Work: G� Application Fee: $10.00 TOTAL DUE: By Signing this application I am stating that I am in compliance with City of Sanford Plumbing Code. Applicant's Signature cFco?_0 303 State License Number SPECIAL POWER OF ATTORNEY Monarch Plumbing, Inc., located at 4060 Commercial Dr., Sebring, Florida 33870, hereby appoints Scott C . Webster , as my Attorney -in -Fact ("Agent"). S.S.#590-50-9426 My Agent shall have full power and authority to act on my behalf but only to the extent permitted by this Special Power of Attorney. My Agent's powers shall include the power to: 1. Manage, control, and operate the business known as: Monarch Plumbing, Inc. 4060 Commercial Dr. Sebring, FL. This power shall include the power to; (i) make and carry out decisions regarding sales, purchases, employees, loans, and equipment, and (ii) take any action needed (at the discretion of my Agent) to operate the business. 2. Prepare, sign, and file documents with any governmental body or agency, including, but not limited to, authorization to: a. Obtain information or documents from any government or its agencies, and negotiate, compromise, or settle any matter with such government or agency (including obtaining permitts). I hereby grant to my Agent the full right, power, and authority to do every act, deed, and thing necessary or advisable to be done regarding the above powers, as fully as I could do if personally present and acting. Any power or authority granted to my Agent under this document shall be limited to the extent necessary to prevent this Power of Attorney from causing; (i) my income to be taxable to my Agent, (ii) my assets to be subject to a general power of appointment by my Agent, and (iii) my Agent to have any incidents of ownership with respect to any life insurance policies that I may own on the life of my Agent. My Agent shall not be liable for any loss that results from a judgment error that was made in good faith. However, my Agent shall be liable for willful misconduct or the failure to act in good faith while acting under the authority of this Power of Attorney. My Agent shall be entitled to reasonable compensation for any services provided as my Agent. My Agent shall be entitled to reimbursement of all reasonable expenses incurred in connection with this Power of Attorney. My Agent shall provide an accounting for all funds handled and all acts performed as my Agent, Initials: A `^► if I so request or if such a request is made by any authorized personal representative or fiduciary acting on my behalf. This Power of Attorney shall become effective immediately. This Power of Attorney shall continue effective until June 30, 2005. This Power of Attorney may be revoked by me at any time by providing written notice to.my Agent. Dated 7j 1W- ?S , 0260 1, at Sebring, Florida. Myllion T rry Webster, Pres. Monarch Plumbing, Inc. Witness Signature Witness Signature STATE OF FLORIDA, COUNTY OFgh % 1v �-S , ss: The foregoing instrument was acknowledged before me this 57% of To N (L , � ' oc� by Monarch Plumbing, Inc., , and , who are personally known to me or who hav oduced as identification. MARY RUTH MtCLELLAND i COMMISSION # CC 696687 o EXPIRES DEC 6, 2001 BONDED THRU ,?,OF FLIP ATLANTIC BONDING CO., INC. - 2 - Initials: N111:10 CITY OF SANFORD ELECTRICAL PERMIT APPLICATION Permit Number: 4 \ - 19iQA Date: S d The undersigned hereby applies for a permit to install the following electrical: TT Owner's Name: MXTS-E Address of Job: OR LA �yo -VR.�� Electrical Contractor: 1 1— 9 1 X, c Residential: Non -Residential:_ Number Amount Addition, Alteration, Repair Residential & Non -Residential) New Residential: AMP Service New Commercial: AMP Service po t OOo Change of Service: From AMP Service to AMP Service Manufactured Building Other. Description of Work. - Application Fee: $10.00 TOTAL DUE: ! o(D By Signing this application I am stating that I am in compliance with City of Sanford,Electrical Code. Signature e&- ©OG_O47t State License Number 4' r 111 Rr 'n r p y'1 , poop f'S 9 a p ,� l ` .aPY..B.�,Aai T.iN K ii11 44 f Y..Ai' 4 x :. sr, � FD4 DR, .....:^ w, .i:s..� .r ,S !1'F iRA x 4,4,E `3.rtl'SF =..:. 3 U R I CHfYY.�e�A..tit OWNER YArAl.- fl 1 fi.. >= i}} t�A O d 'dy n Y 11..k IT,! ,3 Yi you ,,y�{ tt yy 11 ) pp 'd�t F, l.Fil r�'." ...F 4_J �.�>,,. a {�. A'�A ���yu�^i'S7 �°• r 2�f 5'F'� S'.,1A s�.:' i4'?8 t?'.'V A* fS :;�' ( ?, * �Y.. _ _ f � t b } ' 1 K' ...- -� XA g a 1',� I�' a s. k, 101100 11 RA 1-.. k �, 1�' i �` °�! n } .� Retail 5009999 d quAl' e 'Y W, r, ,,FTC" :6.900 30 ff i,a,,.f! 28, 67 1. Q{, 3.,.8 M ;r q X� K.,. - RL E IVE 0 flg':�i � . k +i,. Hil- dFJ" G 10 iqq Oa A L„ 010p Y., F01100 1O M IV 0nrF.. di S. E,." FURF T ,4 1 V LA Pa a'P i sEO i !i kY } 1 t:i05 It! "ti11011 LAB I T Y FOR YR HE f '. F -„ I,Y. r: V E't * .. C E � 3q «, ' 1 °y 'r°�, F° s �a t '' A° � 4,,y_ , E rAII' a t a , '9:.+ sT I. A r3.I'1, 4'`i, 'n t, 'k ,'; .,Y i'fl }'i'.. �a4 �._ P`�S ?zd�; '8 � `b u 'i4 n�1,.��� �, .�.,: QMET: 'F' 1401 '.:` Yyy Fh "� }, - 1 ��:, �.le.. 4nt 1y � 5!iy d`103' {4 ¢ , �. R {.. i ,.. I K ..-�..�F i F ...4.�,. S �S. ��F �4 N i.�l;-}f'.1 L 9,'A �. �: � PERM!!. r r v r A I � a � ' a i 3 ¢ d a � nt i e'}� F � F t. THAT � 94 ANY - ... 1 )���' � ._, .{ Fhi dd ... 09 v k'2..+ F. , t i 9;5'�• i SF i Fl t f i ° h 4 ➢ " a f`,� O St „d:� � � �P Vb, S � �., f„ 3 { .:,,4� 9 l�.f�. � dL P AF - _- p 2Sp y 4 t .. � Ri .� .,{ 4..,. 4^ rR.«i ,7. k.. i.�� �.P �,'� kd 4. r1'- 3 T3'.{'E �, to Q WITHIN ':".. .. YF ;. A:. ._ , �4PF 'i` � .x F F r y: p d+ a � t k, � g,� 4 u; , b i�::� � � i' � {.-, C t�;E �{ a 4 ,.�; ni. 4., .}-�' � tr > � �t � e I, ,'t°;fi� a �'�:� ,i ,y � F 1T 4 � .R, $ � � 'TINT.F �, 4 8 F,is, f i {I �'+�;, } S � i ..km }D k ,i n{ ' 4�'t{3 t�i tiff?f E c 6 ti. R4 } 1` d,.,,4 4Y �i� � w" i ,'i,�O� ,i 1 pp 1 2 F ,s 4: 'T�T..T F.I s64F,f O A 1 A ';1''{ Jf5�^��1 a r��, �,�;x,i 9`�{��,',i4 d Hai'- 4 I )4`; V L 41 4 FT LI � { t i A ....�. k9M 9 F z.N,^,,4. a .,101 E � Y. ..Y'. i >* i .. }. F 6`,1..P t k,.T a r r F.45,KDT MADE TO 4 SEA 1 of TCAACAAAMI _ ORi .�.,,�f, c .67f"d, �i"��..d � � 1 101 cm rmaj Fud ur p t� 55 -..11 ..- A..,., R0 xA� Yy i F F.F{', ., F } s .1i,.' � t F tl,», �- b � xa... ,,,t' ¢. � a,4Y��� ,;." NUTT STIVA0104T. et_', ti%F F. ,?d.$,i 1V,i '.:A 'FT T OR NIVER AT r i TiiP VALID I '' a is 1 �.'A E �9 { { q ! � p '�"{ ;'d ,j MEN .Y. §Y�4d 5[�Y Y YQq I~/ f 1.b Y1,� 9 ��4�}krd_ fd �5-4 * i5 .,fii i.,B 113 QUEER ekMAf�4y, <p f i �A D 11 4 1 Y�i d �^,'ir k DAYS O �� ,r . a t„ ��° 3 3 . �2 a , :, a... 9 9 _ r o �t : A F.. 'Too! i" �,�5 i,. ,..8 tp„ tl :,. CAL L � 0 � 1,54 �+ r" 1 ppd CITY OF SANFORD FIRE DEPARTMENT FEES FOR SERVICES PHONE # 407-302-1091 * FAX #: 407-330-5677 DATE: / Z L V-b PERMIT #: V I `i V BUSINESS NAME / PROJECT: 1104 L ADDRESS: 3 1, 1 4 o o o D P -• PHONE NO.: FAX NO.: CONST. INSP. [ ] C / O INSP.:[ ]. REINSPECTION [ ] PLANS REVIEW [•]/ F. A. [ ] F.S. [ ] HOOD [ ] PAINT BOOTH [ ] BURN PERMIT [ ] TENT PERMIT [ ] TANK PERMIT [ } OTHER [ ] TOTAL FEES: $" LI a 7 L/ L (PER UNIT SEE BELOW) COMMENTS: ui ►ri.'i H if d- 'I- Address / Bldg. # / Unit # Square Footage Fees per Bldg. [Unit 1• �bS3 s. ter 0fi- 03 0,2-i 2. 3. 4. 5. 6 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. ' 19. 20. Fees must be paid to Sanford Building Department, 300 N. Park Ave., Sanford, FI. 32771 Phone # -407- 330-5656. Proof of Payment must be made to Fire Prevention division before any further services can take place. I certify that the above is true and correct and that I will comply with all 943,Rlicable codes and ordinances of the City of Sanfo d, F orida. Sanford Fire Prevention Division Applicant' ignature J 00 00 zL June 25, 2001 01 PINKERTON & LAWS INC. City of Sanford 300 North Park Avenue Sanford, FL 32771 RE: Wal-Mart Supercenter #857 Sanford, Florida To Whom It May Concern: I, Lawrence D. Coil, President of Pinkerton & Laws, Inc., hereby authorize the following individuals: Don Maddox - Superintendent David Moreton — Senior Project Manager to sign on my behalf, under my General Contractor's License, CGC 036253, to obtain the necessary permits and/or licenses for the following: Wal-Mart Supercenter #857 3653 South Orlando Drive Sanford, FL 32773 Sincerely, PINKERT N & LAWS, INC. 1 awrence D. Coil President In witness whereof, the said Lawrence D. Coil has hereunto set his hand this 25th day of June, 2001 Notary Public SHEILAGUINN Notary Public, Cobb County, Georgia '1"i % C01M.Mission Expires July 27, 2004 1165 NORTHCHASE PARKWAY, SUITE 100, MARIETTA, GA 30067 PHONE: 770.956.9000 FAx: 770.618.8686 too-�e CITY OF SANFORD PLANS REVIEW COMMENT SHEET PROJECT- ADDRESS - CONTRACTOR: OWNER: PLANS REVIEWED BY DATE /J - aa- - o-Loo o Ac/c(Il t O 3�53 C��la�do .�i2 Good 1&-zyc- Yo �- 3 o z- 4 4 PERSON NOTIFIED: LC y-Q •e_ DATE: PHONE: NO ONE NOTIFIED: 0 FAX I tL4 -- 7 qq _ b 6 d' � Y DATE RESPONSE RECEIVEED: f Foot 4 i` v�✓ �S C'-.. Ul 5 .�L_4.t-6ee_ UiZL) o�`(�GCe..^/ C�1. � � tve�.i-% 's'\. ��-i.cii✓�e��-l.7 r`<-4 ,^.. At- a-, eel w- ,— gu �r .k. q0�Ci" '`"--4 r t�7 L l S tit c+T LwL\eJ 7 t v�-v J<6L[ �Te�cGi CJp Raymond H. Harris Architect Registration No. AR0014269 211 N. Record St., Ste. 222 Dallas, Texas 75202 Telephone 214/749-0626 October 3, 2000 Mr. Dan Florian Building Official City of Sanford 300 North Park Ave. Sanford, FL 32771 (407) 330-5660 RE: Wal-Mart Store #857 3653 Orlando Dr. Sanford, FL 32773 Supercenter Expansion Project #99127 Dear Mr. Florian: Please accept the enclosed two (2) sets of building plans, (2) two sets of site plans, two (2) sets of specifications and permit application as submission for your review and approval for building permit. If you have any questions or if we can be of any assistance to you during the review process, please do not hesitate to call our office. When you have completed your review, please send written confirmation of your approval to our office. Thank you for your time, and we look forward to receiving your approval. Raymond H. Harris Architect Registration No. AR0014269 211 N. Record St., Ste. 222 Dallas, Texas 75202 Telephone 214/749-0626 October 05, 2000 Mr. Dan Florian Building Official City of Sanford 300 North Park Ave. Sanford, FL 32771 (407) 330-5660 RE: Wal-Mart Store #857 3653 Orlando Dr. Sanford, FL 32773 Supercenter Expansion Project #99127 Dear Mr. Florian: Please accept the enclosed original sealed Energy Efficiency Code for Building as submission for your review and approval for building permit. If you have any questions or if we can, be of any assistance to you during the review process, please do not hesitate to call our office. When pl`T0d�your review, please send written confirmation of your approval to 0 o cep Thank you for your time, and we look incerely 1 Raymond H. Harris RHH/pm Enclosure P.O. Box 1788 Sanford, FL 32772 Fax: (407)330-5677 Phone: (407)330-5656 To: Larae From Jo -Ann M. Johnson Fam (214)749-0601 Pages: 1 Phone: (214)749-0626 Date: 01/18/01 Re: Walmart Superstore/Sanford CC: ❑ Urgent X For Review ❑ Please Comment ❑ Please Reply ❑ Please Recycle • Comments: I have entered your application into our permitting system in order to calculate your permit fees. (copy of fees attached.) We have calculated the sq. footage (for the additional area only) to be 50,666 sq. ft. so your police and fire impact fees are calculated on this figure. I addition to these fees you will need to submit a set of plans to Seminole County Road Impact Fee ivision. You can contact Mary or Brenda at (407)665-7474 for any additional information you may need to obtain the fees. They will give you an impact statement (3 copies) all of which should be given to us so we may add those fees to your building permit fees. I will also need additional permit applications for the Demolition of the retail stores located at 3655, 3657 and 3659 Orlando Dr. We can issue one permit for all locations. The permit fee for this is $25.00. The chain link fence around the condenser pads will also need a separate permit. I will also need 2 copies of the approved site plan once you have final approval from Planning and Engineering. Of course prior to releasing your permit you will need to have a contractor (registered with the City of Sanford) sign our permit application, obtain your Site Development Permit, and record a Notice of Commencement. If you have any questions regarding any of this information please do not hesitate to contact me at (407)330-5656. Jo -Ann MEMO _ . CPH Engineers, Inc. 500 West Fulton Street To: Jo -Ann Johnson Sanford, FL 32771 P. O. Box 2808 From: Irene Boyles Sanford, FL 32772-2808 Subject: Wal-Mart Kimco Site 841 Phone: (407) 36Fax: (407) 330-0-0639 www.cphengineers.com Date: February 9, 2001 cc: Larry Wray Attached are the three copies of the Impact fee Statement from Mary at Seminole County. If you need further assistance, please advise. Thanks Irene J:AW 1374\WORD\MEMO\IB0209CIT.DOC SANFORD • ORLANDO • DELAND • PALM CITY • CAPE CORAL • JACKSONVILLE Jan 16 01 03:05p R mond Harris and Assoc. 2147490601 p.1 i i I Raymond H. Harris Arc ect Registration No. AR0014269 211 N. Record St., Ste. 222 Dallas. Texas 75202 Telephone 214/749-0626 January 15, 2001 Mr. Pete Tucker ` City of Sanford 300 North Park Ave. Sanford, FL 32771 (407)330-5660 RE: Wal-Mart Store #857" 3653 Orlando Dr. Sanford, FL 32773 Supercenter Expansion Project 499127 Dear Mr. Tucker: Please except the following as response to your request: SQUARE FOOTAGE& Total Store Area Actual: (:2:07,:821:S7FD EXPANSION PROJECTS: 1C7 b � Total Store Area Original: 104,680 S.F. �. Expansion Square Footage: : Total Square Footage After Expansion: 207,821 S.F. PERMIT ITEMS: �1So0 1. Compactor drains to building system and sanitary sewer, shown on GP2 and attache �v response per Henderson Engineers. The area drain is fully covered and sealed with cover removal only for cleaning of drain. The area sloped indicated on plan has a curb and sloped away to keep water from entering area. 5:) l Project Name: DEVELOPMENT FEE WORKSHEET CITY OF SANFORD UTILITY - ADMIN. P. 0. BOX 1788 i SANFORD, FL 32772-1788 •i, 4 ,5, V Ce �rUiU Date: /D 1 Owner/Contact Persona Phone: Address I 7 Type of Development: 1) RESIDENTIAL Type of Units (single family or multi -family) Total Number of Units: Type of Utility Connection (individual connections or central water meter & common sewer tap): Water Meter Size (3/411, 1", 2", etc.): REMARKS: 2) NON-RESIDENTIAL Type of,Uriits (commercial, industrial,.etc.): Total Number of Buildings: Number of Fixture Units (each building): Type of Utility Connection (individual connections or central water meter & common sewer tap): Water Meter Size..(3/4" 1", 2", etc.) REMARKS: CONNECTION FEE CALCULATION: Y ' 060C,,,.V Name Signature - Date. I REVISED a� 7 1) water system Impact Fees Equivalent Residential Connection (ERC) - 300 Gallons Per Day (GPD) Residential - $650/Unit - Single family structure, or multi -family unit containing three (3) bedrooms or more. $487.50/Unit - Multi -family unit or Mobile Home unit containing less than three (3) bedrooms. (This category is based on judgement/assumption, estimation that such family units on average require 751 - 225 GPD of the water and sewer service of an average single family unit.) Commercial - $650/ERU - Fixture unit schedule from Southern Plumbing Code will be used. One ERU will be charged for connection and up to twenty (2) fixture units. For projects having more than twenty (20) fixture units the Impact Fee will be determined by increments of 25% based on multiples of five (5) fixture units above the twenty (20) fixture unit base for the first ERU. (Example: twenty-five (25) fixture units will be rated as 1.25 eru; twenty-six (26) fixture units will be rated as 1.5 ERU.) 2) Sewer system Impact Fees Equivalent Residential Connections - 270 Gallons Per Day (GPD) Residential - $1700 Unit - Single family structure, or multi -family unit containing three (3) bedrooms or more. $1275/Unit - Multi -family unit or Mobile Home unit containing less than three (3) bedrooms. (This category is based on judgement/assumption/estimation that such family units on average require 751 of water and sewer service of an average single family unit.) Commercial - Industrial - Institutional $1700/ERU - Fixture unit schedule from Southern Plumbing Code will be used. One ERU will be charged for connection and up to twenty (20) fixture units. For projects having more than twenty (20) fixture units the Impact Fee will be increments of 25% based on multiples of five (5) fixture units above the twenty (20) fixture unit base for the first ERU. (Example: twenty-five (25) fixture units will be rated as 1.25 ERU; twenty-six (26) fixture units will be rated as 1.5 ERU.) /0 � SG+ l� TABLE 709.1 DRAINAGE FIXTURE UNITS FOR FIXTURES AND GROUPS FIXTURE TYPE Automatic clothes washers, commercials DRAINAGE FIXTURE UNIT VALUE AS LOAD FACTORS 3 MINIMUM SIZE OF TRAP (Inches) 2 Automatic clothes washers, residential 2 2 Bathroom group consisting of water closet, lavatory, bidet and bathtub or shower 6 _ Bathtubb (with or without overhead shower or whirlpool attachments) 2 11/2 Bidet 2 11/4 Combination sink and tray 2 11/2 Dental lavatory 1 _ 11/4 Dental unit or cuspidor 1 —" 11/4 Dishwashing machine,c domestic 2 11/2 Drinking fountain 1/2 11/ 4 Emergency floor drain 0 2 Floor drains 2 2 Kitchen sink, domestic 2 11/L Kitchen sink, domestic with food waste grinder and/or dishwasher 2 11/2 Laundry tray (I or 2 compartments) 2 11/2 Lavatory 1 11/a Shower compartment, domestic 2 2 Sink 2 11/2 Urinal 4 Footnote d Urinal, 1 gallon per flush or less 2e Footnote d Wash sink (circular or multiple) each set of faucets 2 11/2 Water closet,_flushometer tank, public or private 4e Footnote d Water closet, private installation 4 Footnote d Water closet, public installation 6 Footnote d ror ai: r mcn = c3-4 mm, I gallon = 3.783 L. 2 For traps larger than 3 inches, use Table 709.2. b A showerhead over a bathtub or whirlpool bathtub attachments does not increase the drainage fixture unit value. c See Sections 709.2 through 709.4 for methods of computing unit value of fixtures not listed in Table 709.1 or for rating of devices with intermittent flows. d Trap size shall be consistent with the fixture outlet size. c For the purpose of computing loads on building drains and sewers, water closets or urinals shall not be rated at a lower drainage fixture unit unless the lower values are confirmed by testing. TABLE 709.2 / DRAINAGE FIXTURE UNITS FOR FIXTURE DRAINS OR TRAPS FIXTURE DRAIN OR TRAP SIZE (inches) DRAINAGE FIXTURE UNIT VALUE 11 /a I 1 1/2 2 2 3 21 /2 4 3 5 4 6 Standard Plumbing Code©19f For SI: 1 inch = 25.4 min: Ph ict I F D .&'hA -Ipoc, 6 o v I S I U;IJ L. t - -- ---- - ----- ----- ------ ............ . . - ------- - ---- ----- ----- e,\ OQORE'" PROPERTY SCIENCE.5 598 S. North Lake Blvd., Suite 1024, Altamonte Springs, FL 32701-5228 (407)645-3400 fax (407) 645-3731 PROJECT: kA, - 7 CLIENT: t%1/n /---/ CONTRACTOR: /'� a s QORE REPRESENTATIVE C K" 0 FIELD REPORT JOB NO.: EPORT NO.: ATE: - WEATHER: ❑ earthwork monitoring ❑ concrete placement ❑ reinforcing steel ❑ asphalt ❑ 7i> C-- S-re v�ul �^,�� a��rio,-� tic..c1 � V���e / Ka I s RECEIVED BY: QORE Property Sciences S/cciiences By The above data have not been reviewed nor checked by our Engineers. This information is submitted for preliminary use only. TFR 151 SPARED -,8/!41/01,- 7:5.6:03 INSPECTION TICKET PAGE 3 `rr 'Y` OF SANFORD INSPECTOR BUILDING DATE 8/14/01 t � -------------------------- )RES"S 3653 ORLANDO DR )DIVISION (TRACTOR PINKERTON & LAWS INC )NE -(407) .660-9494 IER . . . . WAL MART )NE . (504) 204-0489 r �� IZCEL 11.20.30.,.300-035C-0000 1911 j ?LICATION NEW STORES AND CUSTOMER SERVICE ?L NUMBER- 01 00000904 000 000 6ZMIT-TYPE BLDG PERMIT — NEW CONST/ALTER I ----------- .-------------= ----- I?/SQ REQUESTED COMPLETED INSP RESULTS DESCRIPTION/RESULTS/COMMENTS p------------------------------- ------------------------------------------ ------. ` MASONRY .WALL 3RD 4, .FT LIFT E & N 2ND 4FT W 1)2 12 8/08/01 8/08/01 140 AP FOUNDATION INSP�� f CL 05 104 01 f ECL 06 102 13 i FOR THE -GARDEN. CENTER REQUESTING P.M.INSPECTION rr e F. PADS,16 PADS (GARDEN CENTER) 8/08/01. 8/08/01 140 AP" DOWN CELL FOR MASONRY WALL' — 4TH LIFT N & E WALL REQUESTING P.M. INSPECTION 3RD LIFT W WALL 8/08/01 8/06/01 140 AP FRAME 8/09/01 8/09/01 ',JCL 07 8/10/01 a ICL 08- ,05 02 BOLT INSPECTION ON FRONT VESTIBULE AREA. 8/09/01 140 CA DOWN CELL 8/09/01 140 AP ` FOUNDATION INSP FOUNDAT"ION 1 TYPE F `PAD 8/10/01 140 AP DOWN CELL MASONRY WALL Bgbl $ N WALL g/ 14/01 BLDG^ DOGrN CELL 8/14/O1 ' !� y FRONT VE T� 10 A BLDG T. ORE P RO P E R T Y S C I E N C-E S - - 59,8 S. North Lake Blvd., Suite 1024, Altamonte Springs, FL 32701-5228 DEPORT FIELD (407) 645-3400 fax (407) 645-3731 IG L REPORT G A tl A PROJECT: w / - /`'! i �` 7Y a' a 7 JOB NO.: 9'0 'f 7 CLIENT: L1% �j'a i ? 5- T . REPORT NO.: CONTRACTOR: DATE: i I OORE REPRESENTATIVE: WEATHER: Iearthwork monitoring ❑ concrete placement ❑ reinforcing steel ❑ asphalt i j C-C, -1 f.- c� / ,�} <, c, v i�F`� yr y T cJ. ,73 U ��+ ✓" i L� !' .•a'-> �" ll' :£ .. i �.j A/-e GY Y' /,'� ., ?'-- [/.� ' /.(.fie" r� Z' /DCe / GGJTE"/vrc� yC//cXC'/! �PiiC4`r' 7`'/1✓-. I < imationsRent. e,cjo( J RECEIVED BY: QORE Property Sciences By.�'_" The above data have not been reviewed nor checked by our Engineers. This information is 'submitted for preliminary use only. TFR 151 >� `� I ��. � �'S �� .-40 k�a O RT ;'gym P R O P E R T Y S C I E N C E S 598 S. North Lake Blvd., Suite 1024, Altamonte Springs, FL 327C (407) 645-3400 fax (407) 645-3731 PROJECT: ��/« 1 «i 7' r 7 V✓t'. % — i/er y'—; a CLIENT: ,+ CONTRACTOR: nnDC QCDQCQGKITATIVr=• '11 z Ae y l earthwork monitoring ❑ concrete placement ❑ reinforcing steel ❑ asphalt ❑ ep Av Z e- f .-:2:!� 0 4' ?" �' r.� G c>�U r+H H GL G✓ �c ? r <> 7�c� .r ��- cC r!f P. i C. c-7 �I 7f // yl 1X O I U 7" G? r1 ,rJ�cfc� Z`8c%7`cct< Gcivr=r�J y�<r�co7`i��cf { c<,rr yr C �tiT °r' rz-Sc,v?`Le r ,., /'obi Cv / r' . C-i` F' <y C' r ct '-'C/ ce P 4 d 74 S / /t117'C• '.�p 7.c.. x' '�w a t n OR PROPERTY SCIENCES pp p� 598 S. North Lake Blvd., Suite 1024, Altamonte Springs, FL 32701` 5228 FIELD REPORT -(407) 645-3400 fax (407) 645-3731 PROJECT: 7 JOB NO.: 9 Q y CLIENT:_ W ✓- i'%ai'f.- REPORT NO.: CONTRACTOR: F DATE: % QORE REPRESENTATIVE: x G Cam' . y WEATHER:- , � R ❑ earthwork monitoring ❑ concrete placement ❑ reinforcing steel ❑ asphalt ❑ Sir ✓c '�. a -'Z — G c 7Ri o F% G. C." /cto" i/ C!51� 31 � � %r c.f, L7-^/q f/ t a_ GL�� 2 " ri E' it r r ce / tx_ c c 0-11— l "I c P jv%ccsa.>,i y GiotJt �cccic�.f, <� 7'v r!�'.— 3, /�/a /o%e. � �, .� � �' � . Q 7� r�i �' P e�= i'�� �.5 .c-i �.. �''r_� r c-y ,-•�✓F. £ s f i/.Ca TM. PROPERTY SCIENCES 598 S. North Lake Blvd., Suite 1024, Altamonte Springs, FL 327011-5228 (407) 645-3400 fax (407) 645-3731 PROJECT: IAI — CLIENT: r CONTRACTOR: QORE REPRESENTATIVE: ❑ earthwork monitoring ❑ concrete placement ❑ reinforc ng steel FIELD REPORT JOB NO.: REPORT NO.: DATE" WEATHER:' ❑ asphalt ❑ S7"/vC7t/! Sr=fiEc.iv✓l V" vim!; o n �cv /!t' p k �'* G O ,04 7'`U p c'c7 :? c /e, O- el S C 7— 7 C� c/ Gr?r•y� / �' c r d S r r- f-/ �7`. . a u i Permit No. O!- boy Tax Folio No. / m CD NOTICE OF COMMENCEMENT '` r� State of FLORIDA a � t County of Seminole THE UNDERSIGNED hereby gives notice that improvement wlil be made to certain real property, and in C� accordance with Chapter 713, Florida Statues, the following information is provided In this Notice of Commencement. 1. Description of property- Attached hereto as Exhibit "A" and incorporated herein by reference. Street Address- 3653 Orlando Drive, Sanford, Florida 32771-.--- 2. General description of improvement: 207,821 Square Feet Retail Store 3. Owner information: a. Name and Address: Wal-Mart Stores, Inc. Department 8702 2001 S.E. 10th Street Bentonville, Arkansas 72716-0550 r b. Interest in property: rn3 Wal-Mart Stores, Inc. Department 8702 CO "� z 2001 S.E. 101" Street C=) Bentonville, Arkansas 72715-0550 ' C.l1< c) C. Name and Address of Fee Simple Titleholder: Wal-Mart Stores, Inc. Department 8702 2001 S.E. 10'" Street Bentonville, Arkansas 72716-0550 4. Contractor: Pinkerton 8 Laws Company �=C) 901 North Lake Destiny Drive cj Maitland, Florida 32751-4874 P :X rnX 5. Surety: y a- Name and Address: PyT TNIS INStRUN� Hartford Fire Insurance Company C/O Dickey-Mangham Company, Inc. t7 / T II gpDR_ 3715 Northside Parkway Northwest Atlanta, Georgia 30327-28M b. Amount of bond $8,244,000.00 6_ Lender: Not Applicable 7. In addition to himself, Owner designates Construction Department of Wal-Mart Stores, Inc. to receive a copy of the Lienor's Notice as provided in Section 713.13(1) (b), Florida Statues. 8. Expiration date of notice of commencement is June 27, 2002 WAL-MART STORES, INC. By Authorized ent Debbie Gilmore, Manager Contract Administration me this 27th day of June, 2001 Fy i STATE OF FLORIDA COUNTY OF SEMINOLE SEAL This certificate must be attached to the document described at right: The foregoing instrument was acknowledged before me this © �� _ by Xf ft*Ej C - C'f+a of , 4& rw AIM0 Inu S rot. orporatlon, on behalf of the Corporation. He/She n Ily sown to me or has produced as identification and id did not) take an oath. /,a t►1_,c.� Notary Public Signature z Commission No. c c Ajjr,Ze,y_ Notary Name (Type/Print/Stamp) f �,s � Oraee Fizr�A1► My Commission Expires: Title or Type of Document. Notice of Commencement Number of Pages Jr Date of Document _ ®G-,97--a/ Signer(s) other than Named Above r-- Sent.by: CPM Engineers Inc 407 330 0039; 06/27/01 4:1SFM; P*t*4ivUVv �IQ !� stlBJ.&= PAR=_ LEGAL DEScRlPnom PARC U 1 (!OA W PARO . A Pv►wW of rand I)Mg in the SE 1/4 of Sactlon it. Townshto 20 "Uth, Range X eed4 Swoholo County, iToft being, deetwSet as 16tloare: Cafflme"CMQ at the NE o&rW of the of&WOW SC 1/4 of Sedb n 11 es nrtlsrengsd on cwt/ftbd Corner naCord nunnbw 00187TA of the n'ecado of the t7wVv Department of NatkrW RaBounw " tow of Su-W*p and N g, rU n S O?7620" W odony the so8twfy Akre Of the a" � 1/4 of Sortie" 11, 7flfia4 hat to No aoudrefj.'Vht of way fb►e of AJAMCANA 80C11.6VARp c rd the Paver Or OGIAAVIAR UNWW S 0276'26" W Qteng oafs wwstarfy t#14 1182.&1 bet to the St cmmor of the north 1/2of the Sr 1/4 of the afb�r W d SE 1/4 of Ser k" 11: thdPCO N 076'$7' W dOng the south /he of M* sold north 1/Z d0 19 Net' thence A6 2JW 48' & 2J&54 $n4- the Af bB3f'f 1 ` Its 4.Y.00 hrot thence N 2J38'49' & 2800 !bet thence N W71.1 T " W SBJJ; t110ROI N 8J'41'47' It47.OtJ t theN 88'p!'11" W, 1A00 /pet. thence S IJtTB'48" W, 4084 Rsdt; tlns»Ce N 8671'11' W,34d24 list thenas N 2X-V 48" C 13d.t7'D Mgt. thence N 967f'1f' IK Zt ago hey tharf* N 2"B'48` t', 1412S het: theme N 8671'11' W. 27,00 6*1, thence N 23.38'40't" f87.7S* f"t thence S Va7l "1' C .n3 Q0 1b04- theme N 2JW4#' & 81.50 *@C thencee S 6971 *11" bot• E 110-41 lthenoe N 2J39*49" & es 00 hot. th*m# S 8871,11' C 7?Q84 Mot tlahoa N 4722*M* E SZO4 feet; tMM& N 2.TJ8'49' C 114.JJ &et th@vrcb N Ms 11' tp; 2t7�.ZB tat, thence 0ME J<! 23'J849' 14i.t18 f4�et to the efbrwreald ®outherly "Want Of way Me of AMOWCANA DAUGEVARDI tynenea S 7?71tP7' E Wong of wold xWthofy rVht of stay linos 43�78 foot to the PaNr Ole BEC1NA1fN� Contelning 1419,4 Cores matt ar rasa PARCEL 2 (H6W?fi MN PARCE). T061 YWR w7N.• n C O 1.*g /n M# SW f/4 of Ssctlan f$ reeneh47 20 south. Range 30 eat Ss"IhotO tyl being doewfboo Ov lbdowr CbvnmonCinp at the NW Comer of the afbreeON SW 1/4 of Seation 12 as rohron+eoc an osrtfflod comer f@Md number 007074 of the r®ccr* of the A WMV DRoafwbrrent of Notice! RbMOMM, 8wvou of-%'rw)'vtg and MOPPIng, OLM S 087820' W Ofang the tooetefny The of the acid Sw 1/a of Soak:" 1Z 82Q74 feet to the POINT Oi MEOA' RYO Thence S 53'3749" E 2iK83 fact to a flogged 'watlavnds' /,he OF deloictd an a gooey by Anrw&w Svrreybng 8 Mopping, 11M dmwhg tVAvef V P19602W4 abtsd Am. 27, 19997 thwnOo of" aWd ling the PW/ownhg 1J egunesa and dfvhmose S 437622" W. 37M feet; thence S iveirw A 5a0J riot Me" S 0117.12' E, 71.77 feat Mow S J04J'2Y U19 thafree S 6$•44 07' E. Sao$ fast: thence S 26V0'47" 1; MOO !best; VwCa S 0l3l7124" E 72 49 ftot thence S Of'43 30' & 110.22 feet Maw* S OQ 48'J9" W. 97.73 lust thence S 24t90'JB'. 4 20,J4 hot. thence S 4873yS' t", 48.99 het; thence S 32VW 46" f, xze but thence S 4072'3?' E 9bt.i3 fiat; Memo N 897697" W depwfl<ng ofbresafd fldgggd VIP- 17a23 fbat to ft POW of CWWturo of O Curve voecove awtheaatefty how4ng a rodW of 1=00 feat thence through a Centrol angle of 8826J7' no Wang the arc of said Curve 231.34 Mgt to 0 paint of Cusp I'Ag an the afmwov d@yter/y fbe of the SW 1/4 of 3000n 12 then co N 0,776,26' & 10iLE8! liven to the Pmr or SEWifAAWC% CantaAft A&V vows more or' as oARCR S (S 1W PARM): %wTwR WTlt• but part of the aovthmst T/4 of $6006 s It, Townsdrlp 20 south, Range 50 vast. SOMONNs Count,* 7--do, doaaribed as rafows: bnntnrenCpng at the Solt 1/4 Oerner of mid Soadon 11, Town&* 20 south. Range JO east, run S 276W' W ofang the oast lane of the geld aouth>jW T/4 of $OCUon 11, 48a38 fast to the PGOWr r BMNNnVI2 thence cohthuw S 024828' W O/afag eakf 1Me. 23115 loot to the harth Ot-VOL-nthvy Hero of ArnsHMIU $Wdeua/Y'' thanC* N 7/7107' W dlong sold north Rlehr-el-+aby.�ha 3&44 F"t; ttienca N 23'4777" & 223-45 foot, • thence S 7133420t» 34460 rove to eAw PANT of E&AW NC. in tofnbrg J O71 O&W "rare ar /sot 401 Site Centd&Wng 24-405 oaroe mom or lam J BOWJ LEGAL DESCRIP77ON: Parcel of land Wo lb rho — 1 14 -. - VIr 'Sent;by: CPH Engineers Inc 407 330 0630; 08/27/01 4:19Pftl; _I1593;Page 3/3 Peet, thence S 66*21110 r, 31,200 16vtr thence N 23,58,40" r 87.30 !tent; thanes s 6642r.11' & s� 118.41 Met; thanes N 2J39 49' L 96.00 lice(; Chance $ 6621 *11' F- =84 !lest• thence N 47723?' E. 02.04 /bat; Menoe N ?JJU49' E, 174.33 fbet; thence N K201' W, 264JS 1i e4 tholoo N 43'38 46' f . 141.86 Mot to the afatwoW southafr right of way Abra of AMEi?4ANA BOWANARD,• them= S 713107' F along oforaaard southerly rfght of way lh* 45828 last to the POAYT OF KGWNVG Coma"( In owres more or 1WA ,PARCEL 2 (NW7NVGTi N PARLEI X 7A7MMER f1/7Nr A parrs/ of lord I)Mv to the SW //4 of SiVW 12. roWnoh,p 20 swO, ergo JO aost Sernfifole CoMtx i1WMQ bobeg deecrtwd as fbfeww CommeneMy at the NW collar of Me otbresal0 SW 1/4 of SeCtAM 12 ae ralbrWCVd aA oa IXOd can r record M"ber 0018735, of the r000rda of the ROMO 0dpQrbnent of NatWW RCSCWVPe, Vurow of 3Zrt )09 and Mgopha Ain S 0276'26' W along the cravtaty Me of the sW►d SW 1/4 of SwGun 1Z 820.74 feet to the PGNr OF BEGINNM- 7herwe $ 3S37'40' & VOW foot to a Ragged 'wVtfwrda' llhe as dwkted on o survey byAmerkon Surre . 1 .0 A�WI, bee dvwktg nNb►enw 01640ANY, dated .,Me. 27, 1090, thence clang Bold lbro the &ftw fg 70OWsas and 64mcer. S 4534'22' 1K 57.36 het; thence 5 7657'47' W, M 03 Met thence S 02'8l'12' & 71.7J *4 (heron S J043122' F, U 19 het• thence $ 4244'07' & 8505 katt thane S 26110'4r 1r, 85,09 *& thane S 0JB174' $ 72.49 Met; thenoo 5 014998' E 11922 feet; Marro S 001461is' lei 97,7J tW thence S 24W 3r- W, 20:J4 feet; thanes S 467J'1S' E. QL59 fw thence S J2V#*46' 6, 5629 &OC lmo%v S 4072'32' F, SO.JS last; thsnoe N t le'sr W daportbrg OAVVsald ltogrd AW46 17253 fact to Cho PoMt wf Cvrratwv of o avrvw oar ao►e ow&most- havlrrg a retire off 00 Ape(; thence through o rantra/ w4a of 8876'J7' run along the are of sold eraw 231.54 foot to a POW of crap fyft an the afbrve" Westerly too of the SW 114 of Section 1$ thence N me,"" & 1082.81 Met to the pawn OF SFGNMNIZ � Contohi+g 3.320 owes more or /am y PARCEL J (SAQTN PARCEL): lD' MG lMER tit 71h C' r That part of the soutlio"t 1/4 of Scotian 11, roamahp 20 couft N&W JO OWL S9mA70/0 raptx Flo Vk dowrfbed ao me* o Co)wy rcbrg at the east 1/4 comer of sans! Section If. rownsh# ?0 south, Range 30 scot nor S w 02*16*26" W alw►g the east lino of the sold southoost 1/4 of SaotW If, 48338 het to the PONTOD OF REOyNNWa thence cantbus S 0276'26' W along sold IhA 23313 Met to the earth Right-906-f9by The of Amwlcano 8bu/evarit Owme N 71111074 W along mid WM Right-0-IWy lire, 4.3 " Meet; there N 2347'17- E 22145 fact; thence S 7f'3J'42' E, 3"00 foot to the P0/NT OF co ntaAft 2011 bsfee move or /M. Total Site Cantakift 24,483 aaras more of less AA09=M /�` tom_ aGAL DacAYPI70N. 4'I A pored of land I)MO 1W tee SE 1/4 of ssctlon 11, rOM&W 20 SOUth, Range 30 Soft Se-Mb ►e County FkWida, being dlea►tbe4 ds Aef/ars: Cof►+me wmgp at We east 1/4 comer of said SawfAon 12 os refs maW an owffAed comer r000rd n"er 001873A of the rwm* of the f7of94h Oapartmont of Natural Rwwrcm% Bur+ Y of 90 WA9 and m4opb7g, rrn► S 0276*26' W along the ontedy lire of the soid SF 114 of Swim It. 7111 M Arat to a 41lr4' easncreto rnowment & dek stonV64 78 220' sold polht Dears the PANT 4W gWANN O,• trrenoe aontJhve S 02,1620" W along sold easterly /km 03.31 Awt thence N 7137b7- W, 897.SS Ibet to a po ht of non -tangency of a curve conoaw southerly haherg o radttrs of 224.98 feat sale ct/rMe Deft the eatsrfy axtenslon of the northerly ew►w of Mors fond& dowrAbed b of9►tclal Reoorft Bock 2196. page 0W of the Publk Rsoorde of Sembnode Count,% ROFMa6 thence alongp acid northerly cur" and It'* easterly extanslan though a oentraf Wfgle of 24'40'01" run westcrfy MOO feat along the arc of oWd cur+% hat"I a Chord of ff. Tt fftst ankh bears N 897r09' W to a pant of eevwve avrvatury of a eurvie concave, nor Maly hdWOy a moNs of MOO feet; thence continuing olang said northerly aurm thraugff a central w0fe of J27J'Sr run wW14rfy 141.37 fact oton0 the am of sold curve to a point of A00-tdAgenrY on ON southeostWly pot of ray /bhe of V.S Highway 17 & 92, as shown on Florida pspartnrwhf of iftff4P0FT9tlah Not of fOtZy male fir State 'go" 15 df 1900. saotAkre f7714f-203 (-1131 thWxW N MrO Ar E afa+g sold aavbtsosterfy lira 144.e7 fist to a 4'x4 oonortte monument dr disk stomped 16 NO thm-0 S rrAral'" G 7077.M rest to Me POINT OF SEOWNINGr ConW479 I19J varos Mora Of less. SSE S4 f:T 5 OF 5 FOR A L/57WO OF EN V4TRANCES & SURMF�W IS NOTA70M s�lRtJ1C''Yn�P'c' ��nT1F►rr*� �� Go X � ci Q'0. PROPERTY S C I E.NCES 598 S. North Lake Blvd., Suite 1024, Altamonte Springs, FL 32701-5228 FIELD REPORT (407) 645-3400 fax (407) 645-3731 G L REPORT PROJECT: G9�ac%- .`1'vc.-�5 JOB NO.: CLIENT: G. REPORT NO.: CONTRACTOR: DATE:1 QORE REPRESENTATIVE: WEATHER: ❑ earthwork monitoring ❑ concrete placement ❑ reinforcing steel ❑ asphalt. ❑ T 1- t11- c � / t l Nr S� � c )`i + �/ �i c c a �af�p' ✓ � G7 / y 5' •-^ .i . �a ire / � d •*t '.ti.s,s C' ,� . s P �°? 5 , cz. cv tl e" '01 /r cad po.` -I b / ! 4L �° �. , y��- 7` ,✓`1 •x s �v .7 �' Ve ;g a° CC'� f 7' JfGf C k' 1.,77 e e e' 7r e <4 O / 64 7 , r ,-a' s5— 9'''. .3, Z, IV .i' 70t"o" eo' w.1 ., 41 i° ► cell > 7` T o vc ...!21. P rhea .v > ? ce7 ,s/`�r e .*7 e y G+✓ez %✓s RECEIV ED BY:. QORE Property Sciences By The above data have not been reviewed nor checked by our Engineers. This information is submitted for preliminary use only. TFR 151 r PR"0PERTY-SCI E N C E S 598 S. North Lake Blvd., Suite 1024, Altamonte Springs, FL 32701-5228 FIELD REPORT (407) 645-3400 fax (407) 645-3731 t PROJECT: �f«. /-.iy� „--r'�'`.„ JOB NO.: % d S' 7 CLIENT: (A/_�� /`jam -' 7`_ . REPORT NO.: CONTRACTOR: ¢ DATE: i QORE REPRESENTATIVE.[: WEATHER:'[ ❑ earthwork monitoring ❑ concrete_ placement ❑ reinforcing "steel ❑ asphalt ❑ y 0 C. ,� i�,:Ss���' � i�c c.4' 1�"r rr u r � � '�,l'�j". C,,.� � .,�s'�' � :✓ co ,.-s ®'"�,,,' Gr/�Y: / .s. ct. ra aC S A /vya�J c-c P !'• %` `G`J C !" H 9r rl P✓ mC 1 o /' A f .1 e 3 ercv +!/Poo ,GG)of�� r i I a3. RECEIVED BY. d..- 4. Sciences �� � QOREPro pert Y a The above data have not been reviewed nor checked by our Engineer This information is submitted for preliminary use only. TFR 151. TM i PROPER.T'Y 5'CIEN'.CES $' 598 S. North Lake Blvd., Suite 1024 Altamonte Springs, FL32701 5228 FIELD REPORT r (407) 645-3400 fax (407) 645-3731 PROJECT: RA< `. , j'dr a^'i/ JOB NO.: 9'0 ,9' 7 CLIENT: W�aI a,�y.* REPORT NO.: CONTRACTOR: DATE:! 1 ✓� / Gr /' QORE REPRESENTATIVE: / WEATHER: I earthwork monitoring ❑ concrete placement ❑ reinforcing steel ❑ asphalt 0 / ✓ ' / �.. ' 3 - �% �'.� /" �." G'!7 � � �r J'F�" y' �ci ��/✓.�> .,�! �'i /fir'^ ,.{.- � C' "" �" � rC��'F" � l -'`' „y,."!1 V :./"✓`�i %I e`T- G'/'<e o.t i//t?�`� ors ,' i.c r f Ga', r-r�. C •''mot' c Hr .-t ,lam G' ,Air r1 ` -lore r~ a s� Syr P r7 � � %^^ C" �' � ✓�'t� .•' 7 �1 ve 7'� / t 4t ! "t V'o i 1. tIf7W-rb RECEIVED BY: ` QORE,P.rpperty Sciences s � ,The above data have not been reviewed nor checked by our EngineerAThis information is submitted for preliminary use only. TFR 151 TM P,RO'PERTY.SCIENtCES t .598 S. ' North Lake Blvd., Suite 1024, Altmonte Springs, FL 32701-5228 ® REPORT y (407) 645-3400 fax (407) 645-3731 FIE ' GS PROJECT: 7 JOB NO.: CLIENT: wet / //,x t REPORT NO.: CONTRACTOR: DATE: 1 QORE REPRESENTATIVE: WEATHER: �- earthwork monitoring ❑ concrete placement ❑ reinforcing steel ❑ asphalt ❑ C cx, .�+ Y / �•, f�/cC r_- r° C_'c-'ram I F`= 7'-,�-• !s} •t' r.. d �' �" ! G-> c� 'i`v � y =7 � - ,•: 'L,_. %i•/%?c r�,f /G y' c C J Cc7_�t /7cF' ash �rc� .y . er •� " ` ^.:� .•-!"tom >`C`°,cx ...;$ c�c,•7F• .0 i <r C C' 7` y ��.cricf�t"�� C: ca'>fc.""F.. !� ,ir;"'r�'.':-'-tJc='.•�Yr d�•irck'P:f rf r?-�Gf'F-'Gy,; L%' .trd F . c- r-• `7'. c - ! I r'!j /' - G• cJ.,..z. /� / F' ,.. $ r G.� �= ..�+' '7` /' C' r / G./ r7E`. <ry ��f / �•� G±�, F/_ ('.. l / U` <:G i rl /; �r..rY.,S ,t'C`"'C 9°f Q'�% /"f'e"4.".� G." !'C.Y .+• <q fp �"' //! Cl ", J /�.� .. I� s t (,�,. %� .!%�� f�.c%'>;%�` c-� ,/ .� 7'' �' � rt_^ i i/ � f �"'.�rF.•" ,r e.=r_' // �+' r^ � Ct ,. cf'r. r .� r" ,C =: ,`%, r r c- /a /cr r F° s.✓./ r H t G'� 7" ti r d Li r� e=, �/°'c e° (% r 0 f c' ,-,Se,�".ce^.ca lc rk' C. �°' e •a° t� > X I _ ,/' o .--�� sri �,' �' � 1 / G' r'l "�:. r.°'�' �! /� , c� ' �✓e 3 "7"' lt,%c i/� lsC.� �,�.� /iJc� 7`.. p�' / silt • rIT t RECEIVED BY: }' "° ` f QORE Property Sciences - ` By The above data have not been reviewed nor checked by our Engineers. This information is, submitted for preliminary use only. TFR 151 Q 0 R ETm PROPERTY SCIENCES 1211 Tech Boulevard, Suite 200 Tampa FL 33619 Phone: (813)623-6646 Fax: (813) 623-3795 FIELD REPORT PROJECT: 8r3'7 JOB NO.: 5?'S 9 7 CLIENT: L✓«,/— i1��-7 CONTRACTOR: QORE REPRESENTATIVE: 'eL".t4' TIME ARRIVED ON SITE: REPORT NO.: DATE: WEATHER: 7� �- TIME DEPARTED SITE: AS REQUESTED, A QORE REPRESENTATIVE REPORTED TO THE ABOVE REFERENCED PROJECT TO PERFORM EARTHWORKy_'CONCRETE PLACEMENT ASPHALT MONITORING SERVICES. ON THIS DAY THE FOLLOWING WAS NOTED: /'lea•7`o-e-W 7 4e 0 S�C.vw.c// So�.yrC �i.Tm 'Yv/ 'e6 re 7`" -V ,Cast ; t o arcs <zp ,c a O-e c OK�y �r�ecr/' — /5'S8' -' 3.3 STANDBY TIME OF HOURS WAS INCURRED DUE TO UPON DEPARTURE, THE SPECIMEN(S) CAST ON WERE PICKED -UP AND TRANSPORTED BACK TO OUR OFFICE FOR LABORATORY PREPARATION AND TESTING. SPECIMENS DAMAGED ON SITE? I:OT" T:K103 RECEIVED BY: YES NO. IF YES, HOW MANY? QORE, Inc. By The above data has not been reviewed nor checked by our Engineers. This information is submitted for preliminary use only. Q 0 R ETm P R O P E R T Y S C I E N C E 5 1211 Tech Boulevard, Suite 200 Tampa FL 33619 Phone: (813)623-6646 Fax: (813)623-3795 PROJECT: 8�7 CLIENT: CONTRACTOR: QORE REPRESENTATIVE: eL- K TIME ARRIVED ON SITE: REINFORCING STEEL INSPECTION REPORT. JOB NO.: 9 d i REPORT NO.: DATE: WEATHER: TIME DEPARTED SITE: AS REQUESTED, A QORE REPRESENTATIVE ARRIVED ON SITE AND OBSERVED REINFORCING STEEL AT � ,/ S 7—eiKs ccl�/ A5 16 7f`v A/16 i 4cs "/dam REINFORCED STEEL OBSERVED VZWAS WAS NOT IN ACCORDANCE TO PROJECT DRAWINGS AND REQUIREMENTS WITH REGARDS TO BAR SIZE, LENGTH, SPACING, QUALITY AND CLEANLINESS. STANDBY TIME OF HOURS WAS INCURRED DUE TO SEE THE PROJECT PUNCH LIST FOR DEFICIENCIES OBSERVED. RECEIVED BY: QORE, Inc. By °�✓%fi The above data has not been reviewed nor checked by our Engineers. This information is submitted for preliminary use only. ..,a Q 0 R ETm P R O P E R T Y S C I E N C E S 1211 Tech Boulevard, Suite 200 Tampa FL 33619 Phone: (813)623-6646 Fax: (813) 623-3795 REINFORCING STEEL INSPECTION REPORT PROJECT: W,.,/-�- I- --t 6 5 - 7 JOB NO 9'O 7 7 CLIENT: REPORT NO.: CONTRACTOR: QORE REPRESENTATIVE: ,eZ le - TIME ARRIVED ON SITE: DATE: z WEATHER: PC TIME DEPARTED SITE: AS REQUESTED, A QORE REPRESENTATIVE ARRIVED ON SITE AND OBSERVED REINFORCING STEEL AT REINFORCED STEEL OBSERVED P WAS WAS NOT IN ACCORDANCE TO PROJECT DRAWINGS AND REQUIREMENTS WITH REGARDS TO BAR SIZE, LENGTH, SPACING, QUALITY AND CLEANLINESS. STANDBY TIME OF HOURS WAS INCURRED DUE TO SEE THE PROJECT PUNCH LIST FOR DEFICIENCIES OBSERVED. RECEIVED BY: QORE, Inc. By�� ' The above data has not been reviewed nor checked by our Engineers. This information is submitted for preliminary use only. Q 0 R ETM P R O P E R T Y S C I E N C E S 1211 Tech Boulevard, Suite 200 Tampa FL 33619 Phone: (813) 623-6646 Fax: (813)623-3795 REINFORCING STEEL INSPECTION REPORT PROJECT: LA/.,-/- sr S' 7 JOB NO.: i ' 7 CLIENT: W"-/ -Mauer REPORT NO.: CONTRACTOR: DATE: F/z QORE REPRESENTATIVE: WEATHER: C- TIME ARRIVED ON SITE: TIME DEPARTED SITE: AS REQUESTED, A QORE REPRESENTATIVE ARRIVED ON SITE AND OBSERVED REINFORCING STEEL AT f'l�t5dnry Gygc// 3 �•,cr F'�e.�, �3 /1, 7 -r'a q, 3 1//,7 ro A REINFORCED STEEL OBSERVED ✓IWAS WAS NOT IN ACCORDANCE TO PROJECT DRAWINGS AND REQUIREMENTS. WITH REGARDS TO BAR SIZE, LENGTH, SPACING, QUALITY AND CLEANLINESS. STANDBY TIME OF HOURS WAS INCURRED DUE TO SEE THE PROJECT PUNCH LIST FOR DEFICIENCIES OBSERVED. RECEIVED BY: QORE, Inc. By The above data has not been reviewed nor checked by our Engineers. This information is submitted for preliminary use only. 9 Q0RETm P R O P E R T Y S C I E N C E S 1211 Tech Boulevard, Suite 200 Tampa FL 33619 Phone: (813)623-6646 Fax: (813) 623-3795 COMPACTION TEST REPORT PROJECT: 7 JOB NO.: 7e 4' 7 CLIENT: "/«- /- i"1a .- t CONTRACTOR: REPORT NO.: DATE: Z�z z. QORE REPRESENTATIVE: WEATHER: yt:;;'c- TIME ARRIVED ON SITE: TIME DEPARTED SITE: 3. C7 AS REQUESTED, A QORE REPRESENTATIVE REPORTED TO THE ABOVE REFERENCED PROJECT TO PERFORM IN PLACE DESITY TESTING ON A STANDBY BASIS. ON THIS DAY A TOTAL OF `I TEST(S) WAS/WERE PERFORMED AT Gai'c�crt Gc� r�i' S/a 6 Gra�G `�'•� se�� r" Sri-datv�c. Y TEST RESULTS INDICATED THAT COMPACTED FILL IN AREAS AND ELEVATIONS TESTED A" MET DID NOT MEET THE PROJECT'S MINIMUM PERCENT COMPACTION SPECIFICATION. FIELD REPRESENTATIVE FROM Lv� q✓ems r G C /`'l WAS ADVISED OF ALL TEST RESULTS PRIOR TO OUR DEPARTURE FROM THE PROJECT SITE. FIELD TEST DATA � AND TEST RESULTS WILL BE FORWARDED WITH THE NUCLEAR GAUGE DRIVE CYLINDER SAND CONE REPORT. STANDBY TIME OF IHOURS WAS INCURRED DUE TO REMARKS: RECEIVED BY: QORE, Inc. By . . a Q 0 R ETm P R O P E R T Y S C I E N C E S 1211 Tech Boulevard, Suite 200 Tampa FL 33619 Phone: (813) 623-6646 Fax: (813) 623-3795 PROJECT: CLIENT: G✓«� �lu�-� CONTRACTOR: QORE REPRESENTATIVE:. 161-1< TIME ARRIVED ON SITE: FIELD REPORT JOB NO.: 5' % REPORT NO.: DATE: WEATHER: �- TIME DEPARTED SITE: AS REQUESTED, A QORE REPRESENTATIVE REPORTED TO THE ABOVE REFERENCED PROJECT TO PERFORM EARTHWORK CONCRETE PLACEMENT ASPHALT MONITORING SERVICES, ON THIS DAY THE FOLLOWING WAS NOTED: B -1.7' res riT er' /_s .-ss 7e,, /` 1/ "` L. i rC7! et S o d Z11. 7 Tv -4, 3 ,///. 7 TO d..3 1/ STANDBY TIME OF HOURS WAS INCURRED DUE TO UPON DEPARTURE, THE SPECIMEN(S) CAST ON OFFICE FOR LABORATORY PREPARATION AND TESTING. SPECIMENS DAMAGED ON SITE? YES REMARKS: WERE PICKED -UP AND TRANSPORTED BACK TO OUR NO. IF YES, HOW MANY? RECEIVED BY: QORE, Inc. The above data has not been reviewed nor checked by our Engineers. This information is submitted for preliminary use only. Q 0 R ETm P R O P E R T Y S C I E N C E 5 1211 Tech Boulevard, Suite 200 Tampa FL 33619 Phone: (813)623-6646 Fax: (813)623-3795 PROJECT: ±iA-4, , - `* 6,.., —'— CLIENT CONTRACTOR: REINFORCING STEEL INSPECTION REPORT JOB NO.:� REPORT NO.: DATE: >= 5 QORE REPRESENTATIVE:' WEATHER: TIME ARRIVED ON SITE: TIME DEPARTED SITE: AS REQUESTED, A QORE REPRESENTATIVE ARRIVED ON SITE AND OBSERVED REINFORCING STEEL AT REINFORCED STEEL OBSERVED /IWAS WAS NOT IN ACCORDANCE TO PROJECT DRAWINGS AND REQUIREMENTS WITH REGARDS TO BAR SIZE, LENGTH, SPACING, QUALITY AND CLEANLINESS. STANDBY TIME OF HOURS WAS INCURRED DUE TO SEE THE PROJECT PUNCH LIST FOR DEFICIENCIES OBSERVED. RECEIVED BY: QORE, Inc. By The above data has not been reviewed nor checked by our Engineers. This information is submitted for preliminary use o '(y. rm Q O R E P R O P E R T Y S C I E N C E S 1211 Tech Boulevard, Suite 200 Tampa FL 33619 Phone: (813)623-6646 Fax: (813)623-3795 COMPACTION TEST REPORT PROJECT: V1�-e ,1-r -'° %' JOB NO.: CLIENT:~' _ ` '` °'� REPORT NO.: CONTRACTOR: DATE: QORE REPRESENTATIVE: A",r: WEATHER TIME ARRIVED ON SITE: TIME DEPARTED SITE: AS REQUESTED, A QORE REPRESENTATIVE REPORTED TO THE ABOVE REFERENCED PROJECT TO PERFORM IN PLACE DESITY TESTING ON A STANDBY BASIS. ON THIS DAY A TOTAL OF !E. TEST(S) WAS/WERE PERFORMED AT �° s, .x. • �, < _ , _:� rs < w� - f TEST RESULTS INDICATED THAT COMPACTED FILL IN AREAS AND ELEVATIONS TESTED %" f, MET DID NOT MEET THE PROJECT'S MINIMUM PERCENT COMPACTION SPECIFICATION. FIELD REPRESENTATIVE FROM WAS ADVISED OF ALL TEST RESULTS PRIOR TO OUR DEPARTURE FROM THE PROJECT SITE. FIELD TEST DATA B' AND TEST RESULTS'WILLE FORWARDED WITH THE " NUCLEAR GAUGE DRIVE CYLINDER SAND CONE REPORT. STANDBY TIME OF HOURS WAS INCURRED DUE TO REMARKS: RECEIVED BY: QORE, Inc. Q0RETm PROPERTY SC I E N C E S 1211 Tech Boulevard, Suite 200 Tampa FL 33619 Phone: (813) 623-6646 Fax: (813) 623-3795 FIELD REPORT PROJECT: VA, JOB NO.: CLIENT: �'111_e/" - 4,V REPORT NO.: CONTRACTOR:— DATE: QORE REPRESENTATIVE:— WEATHER: TIME ARRIVED ON SITE: TIME DEPARTED SITE: AS REQUESTED, A QORE REPRESENTATIVE REPORTED TO THE ABOVE REFERENCED PROJECT TO PERFORM EARTHWORK `--"CONCRETE PLACEMENT ASPHALT MONITORING SERVICES. ON THIS DAY THE FOLLOWINGWAS NOTED: 7— STANDBY TIME OF HOURS WAS INCURRED DUE TO UPON DEPARTURE, THE SPECIMEN(S) CAST ON WERE PICKED -UP AND TRANSPORTED BACK TO OUR OFFICE FOR LABORATORY PREPARATION AND TESTING. SPECIMENS DAMAGED ON SITE? YES NO. IF YES, HOW MANY? REMARKS: RECEIVED BY: QORE, Inc. By The above data has not been reviewed nor checked by our Engineers. This information is submitted for preliminary use only. Q 0 R ET" P R O P E R T Y S C I E N C E S 1211 Tech Boulevard, Suite 200 Tampa FL 33619 Phone; (813)623-6646 Fax:` (813)623-3795 PROJECT: 01, � �, �,_� � _ J CLIENT: CONTRACTOR: QORE REPRESENTATIVE: TIME ARRIVED ON SITE: COMPACTION TEST REPORT JOB NO.: REPORT NO.: DATE: WEATHER: TIME DEPARTED SITE: AS REQUESTED, A QORE REPRESENTATIVE REPORTED TO THE ABOVE REFERENCED PROJECT TO PERFORM. IN PLACE DESITY TESTING _ ON A STANDBY BASIS. ON THIS DAY A TOTAL OF TEST(S) WAS/WERE PERFORMED AT l� TEST RESULTS INDICATED THAT COMPACTED FILL IN AREAS AND ELEVATIONS TESTED'' MET DID NOT MEET THE PROJECT'S MINIMUM PERCENT COMPACTION SPECIFICATION. FIELD REPRESENTATIVE FROM WAS ADVISED OF ALL TEST RESULTS PRIOR TO OUR DEPARTURE FROM THE PROJECT SITE. FIELD TEST DATA AND TEST RESULTS WILL BE FORWARDED WITH THE °NUCLEAR GAUGE DRIVE CYLINDER SAND CONE REPORT: STANDBY TIME OF HOURS WAS INCURRED DUE TO REMARKS: RECEIVED BY: QORE, Inc. QORETm PROPERTY SCIENCES 1211 Tech Boulevard, Suite 200 k Tampa FL 33619 FIELD REPORT Phone: (813)623-6646 Fax: (813) 623=3795 PROJECT: Vl--l- JOB NO.: CLIENT: A/ f REPORT NO.: CONTRACTOR: DATE: QORE REPRESENTATIVE:L� WEATHER: TIME ARRIVED ON SITE: TIME DEPARTED SITE: AS REQUESTED, A QORE REPRESENTATIVE REPORTED TO THE ABOVE REFERENCED PROJECT TO PERFORM EARTHWORK � CONCRETE PLACEMENT ASPHALT MONITORING SERVICES. ON'yIS DAY THE FOLLOWING WAS NOTED: /`�a ��o� '� r1,_C ,/ -ti W? ✓°_'" .. R Y �^.%} ` .fi «,:;: ,:::'4 ..k w ,.� !�+ Tv�` s, �� , ,r ,..J.,.4. • ,+..w e',. It - y, fir..: F ti ,-.c" =k �-. #- r,r= ✓ w �, _, .tX�.Fa v. '""'`�s�a5'" v� `"�: '.' :c=.:" Y,*�t. :m w. STANDBY TIME OF HOURS WAS INCURRED DUE TO UPON DEPARTURE, THE SPECIMEN(S) CAST ON ' v'' WERE PICKED -UP AND TRANSPORTED BACK TO OUR OFFICE FOR LABORATORY PREPARATION AND TESTING. SPECIMENS DAMAGED ON SITE? YES .-"}~ NO. IF YES, HOW MANY? REMARKS: RECEIVED BY: QORE, Inc. The above data has not been reviewed nor checked by our Engineers. This information is submitted for preliminary use only. c Q 0 R ETm , P R O P E R T Y S C I E N C E S 1211 Tech Boulevard, Suite 200 Tampa FL 33619 Phone: (813)623-6646 Fax: (813) 623-3795 , REINFORCING STEEL INSPECTION REPORT PROJECT: JOB NO.: CLIENT: = REPORT NO.: CONTRACTOR: DATE: .tea QORE REPRESENTATIVE: WEATHER: == TIME ARRIVED ON SITE: TIME DEPARTED SITE: AS REQUESTED, A QORE REPRESENTATIVE ARRIVED ON SITE AND OBSERVED REINFORCING STEEL AT .� REINFORCED'STEEL OBSERVED ��' WAS WAS NOT IN ACCORDANCE TO PROJECT DRAWINGS AND REQUIREMENTS WITH REGARDS TO BAR SIZE, LENGTH, SPACING, QUALITY AND CLEANLINESS. STANDBY TIME OF HOURS WAS INCURRED DUE TO SEE THE PROJECT PUNCH LIST FOR DEFICIENCIES OBSERVED. RECEIVED BY: QORE, Inc. The above data has not been reviewed nor checked by our Engineers. This information is submitted for preliminary use only. Q 0 R ETm P R O P E R T Y S C I E N C E S 1211 Tech Boulevard, Suite 200 Tampa FL 33619 Phone: (813)623-6646 Fax: (813)623-3795 PROJECT: 7- &s7 CLIENT: t.✓'-•--.'ra--r' CONTRACTOR: QORE REPRESENTATIVE: Tel- K TIME ARRIVED ON SITE: AS REQUESTED, A QORE REPRESENTATIVE ARRIVED ON SITE AND OBSERVED REINFORCING STEEL AT REINFORCING STEEL INSPECTION REPORT JOB NO.: 70 97 REPORT NO.: DATE: s"Iz 8' WEATHER: f G TIME DEPARTED SITE: REINFORCED STEEL OBSERVED WAS WAS NOT IN ACCORDANCE TO PROJECT DRAWINGS AND REQUIREMENTS WITH REGARDS TO BAR SIZE, LENGTH, SPACING, QUALITY AND CLEANLINESS. STANDBY TIME OF HOURS WAS INCURRED DUE TO SEE THE PROJECT PUNCH LIST FOR DEFICIENCIES OBSERVED. RECEIVED BY: QORE, Inc. By The above data has not been reviewed nor checked by our Engineers. This information is submitted for preliminary use only. Q 0 R ETm PROPERTY SCIENCES 1211 Tech Boulevard, Suite 200 Tampa FL 33619 Phone: (813)623-6646 Fax: (813) 623-3795 PROJECT: �✓'�-iY-�� �` S-s 7 CLIENT: L4/'cr,/.-1-/- CONTRACTOR: QORE REPRESENTATIVE TIME ARRIVED ON SITE: JOB NO.: 9 O l 7 REPORT NO.: DATE: 5- z y L. WEATHER: TIME DEPARTED SITE: AS REQUESTED, A QORE REPRESENTATIVE REPORTED TO THE ABOVE REFERENCED PROJECT TO PERFORM EARTHWORK k` CONCRETE PLACEMENT ASPHALT MONITORING SERVICES. ON THIS DAY THE FOLLOWING WAS NOTED: Kati farms pl¢ C e'` 0'7� Cv -� c -c G C 40es -e r .s de d.S &4.1 —,41 C 0 l v.+r n �'O B� - -7 .S f ecei c r Cc/ e S �Y a o d r' G�. li it C• r S TOE'C49f rCSS i✓r S7'/Cr! /i B l C W m . V-- S �7`' C 1 G d✓ 7`- 4F -:.s-`-.s 74 Cl If ^42110 0'. y !.t/oc.// STANDBY TIME OF HOURS WAS INCURRED DUE TO UPON DEPARTURE, THE SPECIMEN(S) CAST ON OFFICE FOR LABORATORY PREPARATION AND TESTING SPECIMENS DAMAGED ON SITE? YES REMARKS: WERE PICKED -UP AND TRANSPORTED BACK TO OUR NO. IF YES, HOW MANY? RECEIVED BY: QORE, Inc. By .� The above data has not been reviewed nor checked by our Engineers. This information is submitted for preliminary use only. r ,,a, Q OR ETm PROPERTY SCIENCES 1211 Tech Boulevard, Suite 200 Tampa FL 33619 Phone: (813)623-6646 Fax: (813)623-3795 PROJECT: (A/-,e,/...mac.-f '00—' 61 S 7 REINFORCING STEEL INSPECTION REPORT JOB NO.: io i7 CLIENT: G✓1"—/- �-�r�` REPORT NO.: CONTRACTOR: QORE REPRESENTATIVE TIME ARRIVED ON SITE: ,ole Z- /e C ! :4 GcAj�r cs--7 DATE: Z/Z WEATHER: /f' TIME DEPARTED SITE / '/ 5-� — 3. 6 AS REQUESTED, A QORE REPRESENTATIVE ARRIVED ON SITE AND OBSERVED REINFORCING STEEL AT / CerJY'/.ttlpUs i.i��( C®Oi�in�J �io�lf�+il TG4�S7�cr�S �/'�✓Y �°-La.Sa�►rr t,✓Q/� 3'' G.�'r �c'�'ow� A.3 /O. Z r-m R. 3 REINFORCED STEEL OBSERVED t/WAS WAS NOT IN ACCORDANCE TO PROJECT DRAWINGS AND REQUIREMENTS WITH REGARDS TO BAR SIZE, LENGTH, SPACING, QUALITY AND CLEANLINESS. STANDBY TIME OF HOURS WAS INCURRED DUE TO SEE THE PROJECT PUNCH LIST FOR DEFICIENCIES OBSERVED. RECEIVED BY: QORE, Inc. By The above data has not been reviewed nor checked by our Engineers. This information is submitted for preliminary use only. I , ' a Q 0 R ETm PROPERTY SCIENCES 1211 Tech Boulevard, Suite 200 Tampa FL 33619 Phone: (813)623-6646 Fax: (813)623-3795 PROJECT: # 5- 7- CLIENT: tv'«-� CONTRACTOR: QORE REPRESENTATIVE:_ TIME ARRIVED ON SITE: REINFORCING STEEL. INSPECTION REPORT JOB NO.: % D S' 7 REPORT NO.: DATE: �g-l3 iQ L A. WEATHER: ' TIME DEPARTED SITE: AS REQUESTED, A QORE REPRESENTATIVE ARRIVED ON SITE AND OBSERVED REINFORCING STEEL AT REINFORCED STEEL OBSERVEDyWAS WAS NOT IN ACCORDANCE TO PROJECT DRAWINGS AND REQUIREMENTS WITH REGARDS TO BAR SIZE, LENGTH, SPACING, QUALITY AND CLEANLINESS. STANDBY TIME OF HOURS WAS INCURRED DUE TO SEE THE PROJECT PUNCH LIST FOR DEFICIENCIES OBSERVED. RECEIVED BY: QORE, Inc. By The above data has not been reviewed nor checked by our Engineers. This information is submitted for preliminary use only. Q O`R E P R O P E R T Y S C I E N C E S 1211 Tech Boulevard, Suite 200 Tampa FL 33619 Phone: (813) 623-6646 Fax: (81.3) 623-3795 COMPACTION TEST REPORT PROJECT: Sr' -'g- -7 JOB NO.: 570 5;" 7 CLIENT: 7- REPORT NO.: CONTRACTOR: DATE: /3 a QORE REPRESENTATIVE: WEATHER: f' L TIME ARRIVED ON SITE: TIME DEPARTED SITE: 5le c . r%'c mfi d �r Z "� O Q ^ 3 . e $' AS REQUESTED, A QORE REPRESENTATIVE REPORTED TO THE ABOVE REFERENCED PROJECT TO PERFORM IN PLACE DESITY TESTING ON A STANDBY BASIS. ON THIS DAY A TOTAL OF 3 TEST(S) WAS/WERE PERFORMED AT Se,�.so�se�/ mac. TEST RESULTS INDICATED THAT COMPACTED FILL IN AREAS AND ELEVATIONS TESTED MET DID NOT MEET THE PROJECT'S MINIMUM PERCENT COMPACTION SPECIFICATION. FIELD REPRESENTATIVE FROM G C�-J WAS ADVISED OF ALL TEST RESULTS PRIOR TO OUR DEPARTURE FROM THE PROJECT SITE. FIELD TEST DATA AND TEST RESULTS WILL BE FORWARDED WITH THE 1,�NUCLEAR GAUGE DRIVE CYLINDER SAND CONE REPORT. STANDBY TIME OF HOURS WAS INCURRED DUE TO RECEIVED BY: QORE, Inc. Q 0 R E' PROPERTY SC IEN CES 1211 Tech Boulevard, Suite 200 Tampa.FL 33619 ' Phone: (813)623-6646 Fax: (813)623-3795 REINFORCING STEEL INSPECTION REPORT PROJECT: JOB NO.: 7d 9 7 CLIENT: REPORT NO.: CONTRACTOR: DATE: ? 3 'QORE REPRESENTATIVE: WEATHER:'c- TIME ARRIVED ON SITE: TIME DEPARTED SITE: AS REQUESTED, A QORE REPRESENTATIVE ARRIVED ON SITE AND OBSERVED REINFORCING STEEL AT<<� liaso,a � •- Gva l� !�'/'vrr f% 3 l4. Z 7`0 009.. .317 ECG , -;-,n �E'/G Z KE-- G_� s�T` -- REINFORCED STEEL OBSERVED WAS WAS NOT IN ACCORDANCE TO PROJECT DRAWINGS AND REQUIREMENTS WITH REGARDS TO BAR SIZE, LENGTH, SPACING, QUALITY AND CLEANLINESS. STANDBY TIME OF HOURS WAS INCURRED DUE TO SEE THE PROJECT PUNCH LIST FOR DEFICIENCIES OBSERVED. RECEIVED BY: QORE, Inc. By The above data has not been reviewed nor checked by our Engineers. This information is submitted for' preliminary use only. Q 0 R ETm P R O P E R T Y S C I E N C E S 1211 Tech Boulevard, Suite 200 Tampa FL 33619 Phone: (813)623-6646 Fax: (813)623-3795 PROJECT: JOB NO.: ie 5�- CLIENT: i` REPORT NO.: CONTRACTOR: DATE: 3/ QORE REPRESENTATIVE: /C / --- WEATHER: C � FIELD REPORT TIME ARRIVED ON SITE: TIME DEPARTED SITE: AS REQUESTED, A QORE REPRESENTATIVE REPORTED TO THE ABOVE REFERENCED PROJECT TO PERFORM EARTHWORK CONCRETE PLACEMENT ASPHALT MONITORING SERVICES. ON THIS DAY THE FOLLOWING WAS NOTED: .s -,co/1 -"r -da o' s- -741 STANDBY TIME OF HOURS WAS INCURRED DUE TO UPON DEPARTURE, THE SPECIMEN(S) CAST ON OFFICE FOR LABORATORY PREPARATION AND TESTING. SPECIMENS DAMAGED ON SITE? YES REMARKS: WERE PICKED -UP AND TRANSPORTED BACK TO OUR NO. IF YES, HOW MANY? RECEIVED BY: QORE, Inc. By, The above data has not been reviewed nor checked by our Engineers. This information is submitted for preliminary use only. Q O R ETm PROP E R T Y S C I E N C E S 598 S. North Lake Blvd., Suite 1024 Altamonte Springs, FL 32801 REINFORCING STEEL INSPECTION REPORT Phone: (407)645-3400 Fax: (407) 645-3731 PROJECT: �t/� �- ���'��-57 JOB NO.: 90 % 7 CLIENT: W - /-/`/ai7` REPORT NO.: CONTRACTOR: DATE: QORE REPRESENTATIVE: WEATHER: TIME ARRIVED ON SITE: "r- C--- TIME DEPARTED SITE: $�cc:rcu7`.cv �ys-g _ 3 AS REQUESTED, A QORE REPRESENTATIVE ARRIVED ON SITE AND OBSERVED REINFORCING STEEL AT /`7•rs o ,r .- y a../ 3 �� L r �'r �r d -"z 6 �-� /� / � �• /� STes. �✓��� �rm� -/ TO 6 c�/•- +. S L' .G/ S d-� �c / f cr AI -7`s t L✓�cs 4 c� S REINFORCED STEEL OBSERVED WAS WAS NOT IN ACCORDANCE TO PROJECT DRAWINGS AND REQUIREMENTS WITH REGARDS TO BAR SIZE, LENGTH, SPACING, QUALITY AND CLEANLINESS. STANDBY TIME OF HOURS WAS INCURRED DUE TO SEE THE PROJECT PUNCH LIST FOR DEFICIENCIES OBSERVED. RECEIVED BY: QORE, Inc. By✓���' The above data has not been reviewed nor checked by our Engineers. This information is submitted for preliminary us only. MIN Q 0 R ETm P R O P E R T Y S C I E N C E S 1211 Tech Boulevard, Suite 200 Tampa FL 33619 Phone: (813)623-6646 Fax: (813)623-3795 PROJECT: FIELD REPORT JOB NO.: p % CLIENT: JA. 1_"'-e ,"7- REPORT NO.: CONTRACTOR: DATE: QORE REPRESENTATIVE: /CL WEATHER: TIME ARRIVED ON SITE: TIME DEPARTED SITE: AS REQUESTED, A QORE REPRESENTATIVE REPORTED TO THE ABOVE REFERENCED PROJECT TO PERFORM EARTHWORK CONCRETE PLACEMENT ASPHALT MONITORING SERVICES. ON THIS DAY THE FOLLOWING WAS NOTED: / .90 O STANDBY TIME OF HOURS WAS INCURRED DUE TO UPON DEPARTURE, THE SPECIMEN(S) CAST ON WERE PICKED -UP AND TRANSPORTED BACK TO OUR OFFICE FOR LABORATORY PREPARATION AND TESTING. SPECIMENS DAMAGED ON SITE? YES NO. IF YES, HOW MANY? REMARKS: RECEIVED BY: QORE, Inc. The above data has not been reviewed nor checked by our Engineers. This information is submitted for preliminary use only. Q 0 R E.. P R O P E R T Y S C I E N C E 5 1211 Tech Boulevard, Suite 200 Tampa FL 33619 Phone: (813)623-6646 Fax: (813)623-3795 FIELD REPORT PROJECT: ,- JOB NO.: Id 7 7 CLIENT: ! -7-- REPORT NO.: CONTRACTOR: DATE: 9 QORE REPRESENTATIVE: "PG /C WEATHER: /'f' TIME ARRIVED ON SITE: TIME DEPARTED SITE: AS REQUESTED, A QORE REPRESENTATIVE REPORTED TO THE ABOVE REFERENCED PROJECT TO PERFORM EARTHWORK CONCRETE PLACEMENT ASPHALT MONITORING SERVICES. ON THIS DAY THE FOLLOWING WAS NOTED: /`lol�c�C "o, 5 -7"- a STANDBY TIME OF HOURS WAS INCURRED DUE TO UPON DEPARTURE, THE SPECIMEN(S) CAST ON % WERE PICKED -UP AND TRANSPORTED BACK TO OUR OFFICE FOR LABORATORY PREPARATION AND TVtT NG. SPECIMENS DAMAGED ON SITE? REMARKS: RECEIVED BY: YES k--'NO. IF YES, HOW MANY? QORE, Inc. The above data has not been reviewed nor checked by our Engineers. This information is submitted for preliminary use only. Q O R ETm PROPERTY SCIENCES 598 S. North Lake Blvd., Suite 1024 Altamonte Springs, FL 32801 Phone: (407) 645-3400 Fax: (407) 645-3731 REINFORCING STEEL INSPECTION REPORT PROJECT: r Fss 7 JOB NO.: 9o5� 7 CLIENT: 14/-/-M� ' f REPORT NO.: CONTRACTOR: DATE: � QORE REPRESENTATIVE: �G WEATHER: PC' TIME ARRIVED ON SITE: TIME DEPARTED SITE: 2�eG�c.cc.f',ca� AS REQUESTED, A QORE REPRESENTATIVE ARRIVED ON SITE AND OBSERVED REINFORCING STEEL AT 7 O REINFORCED STEEL OBSERVED "AS WAS NOT IN ACCORDANCE TO PROJECT DRAWINGS AND REQUIREMENTS WITH REGARDS TO BAR SIZE, LENGTH, SPACING, QUALITY AND CLEANLINESS. STANDBY TIME OF HOURS WAS INCURRED DUE TO SEE THE PROJECT PUNCH LIST FOR DEFICIENCIES OBSERVED. PORE, Inc. By The above data has not been reviewed nor checked by our Engineers. This information is submitted for preliminary use only. PROP E R T Y S C I E N C E S 598 S. North Lake Blvd., Suite 1024 Altamonte Springs, FL 32801 REINFORCING STEEL INSPECTION REPORT Phone: (407) 645-3400 Fax: (407) 645-3731 PROJECT: 65"7 JOB NO.: i O y 7 CLIENT: REPORT NO.: CONTRACTOR: DATE: QORE REPRESENTATIVE: iP WEATHER: TIME ARRIVED ON SITE: TIME DEPARTED SITE: AS REQUESTED, A QORE REPRESENTATIVE ARRIVED ON SITE AND OBSERVED REINFORCING STEEL AT /-/4.s--y - 7 uju1x ,? "W I-;' 'r Fi-,, /</ / 7--0 &/ REINFORCED STEEL OBSERVED V WAS WAS NOT IN ACCORDANCE TO PROJECT DRAWINGS AND REQUIREMENTSWITH REGARDS TO BAR SIZE, LENGTH, SPACING, QUALITY AND CLEANLINESS. STANDBY TIME OF HOURS WAS INCURRED DUE TO SEE THE: PROJECT PUNCH LIST FOR DEFICIENCIES OBSERVED. RECEIVED BY: QORE, Inc. By vn The above data has not been reviewed nor checked by our Engineers. This information is submitted for preliminary use only. CITY OF SANFORD PLANS REVIEW COMMENT SHEET DATE - s / PROJECT: ul I i - m a ADDRESS: CONTRACTOR: OWNER: (.lea. << - M n c lL PLANS REVIEWED BY: ZA t aftk -107 30 Z - Q Y17 COMMENTS! ( a Z000 G1 os ,/lco,,- Cco hvllec_� A-o sa,,;,, pv\ .4 cJ1 .5 J+2n iQ. 0- PERSON NOTIFIED: lc, o. r c. PHONE: NO ONE NOTIFIED: DATE: FAX _74-19 0 6 0 1 c DATTJE( RESPONSE RECEIVED: /� C'`C'G �L� �.t�e� Lornv.c e 4, �1dCJve 55 C'�w.w,e.�r Jan 16 01 03:05p Raymond Harris and Assoc. 2147490601 p.3 Mr. Pete Tucker January 15, 2001 Page 3 of 3 Provided Water ClosetsJUrinals 8 8 16 Accessible Toilet 1 1 Pharmacy 1 I Total Provided 8 10 18 Required Lavatories (1 /750) (1/750) 1-700 1 1 2 Total Required 1 1 2 Provided Lavatories 9 9 18 Accessible Toilet I Pharmacy 1 Total Provided 20 Required Drinking Fountains 4 Provided Drinking Fountains 4 Thank you for your time, and we look forward to receiving your approval. Sincerely, T Raymond . Harris RHHAs Jan 16 01 03:05p Raymon'd:Harris and Assoc. 2147490601 p.2 Mr. Pete Tucker January 15, 2001 rage 2 of 3 2. Fixture calculations: 94 SBC Code: Total Building Area: 207,821 Square Feet Occupant Square Footage: 200 Square Feet ! Person Occupant Load: Men Women Total 416 624 1,040 Fixtures Units Units Total Units Required Water Closets(Urinals 1-150 8 15 23 151-624 (1200) 2 5 7 Total Required 10 20 30 Provided'Water Closets/Urinals 8 8 16 Accessible Toilet I I Pharmacy I 1 Total Provided 8 10 18 Required Lavatories 1-125 5 10 15 126-520 (1/200) 2 5 _7 Total Required 7 15 22 Provided Lavatories 9 9 18 Accessible Toilet I Pharmacy 5 Total Provided 20 Required Drinking Fountains 4 Provided Drinking Fountains 4 The facility does not meet the 1994 requirements at current code for plumbing and the building is being built under the 1997 Building Code and under the 1997 Plumbing Code the building meets the requirements and I understand that the. city has adopted the 1997 code effective in ,tune of 2001, so this is a request for the building to be under the new adopted code. Fixture calculations: 1997 SBC Code: Total Building Area: 207,821 Square Feet Occupant Square Footage: 200 Square Feet / Person Occupant Load: Men Women Total 416 624 1,040 Fixtures Units Units Total Units Required Water ClosetsfUrinals (11500) (11500) 1-500 1 1 2 501-624 _ 1 1 Total Required 1 2 3 Jan 16 0'1 03:05p Raymond Harris and Assoc. .2147490601 p.1 Raymond H. Harris Architect Registration No. AR0014269 211 N. Record St.,, Ste_ 222 Dallas, Texas 75202 Telephone 214/749-0626 January 15, 2001 Mr. Pete Tucker City of Sanford 300 North Park Ave. Sanford, FL 32771 (407) 330-5660 RE: Wal-Mart Store #857 3653 Orlando Dr, Sanford, FL 32773 Supercenter Expansion Project #99127 Dear Mr. Tucker: Please except the following as response to your request: SQUARE FOOTAGES: Total Store Area Actual: 207,821 S.F. EXPANSION PROJECTS: Total Store Area Original: 104,680 S.F. Expansion Square Footage: 103,141 S.F. Total Square Footage After Expansion: 207,821 S.F. PERMIT ITEMS: 1. Compactor drains to building system and sanitary sewer, shown on GP2 and attache response per Henderson Engineers. The area drain is fully covered and sealed with cover removal only for cleaning of drain. The area sloped indicated on plan has a curb and sloped away to keep water from entering area. • r. T I 18' 411 REMOVE EXISTING FACES THAT ARE PLEXIGLASS FABRICATE AND INSTALL NEW FLEX FACES WITH INTERNAL FRAMEWORK AND NEW 4.5" CAPPING. PAINT CAPPING BLUE TO MATCH FACES EXISTING SIGN FILE NAME - WALMARTSANFORD 2Na i"' ffll�%ORIDA SIONzCOMPANK DATE PREPARED - 3/6/02 AMPS REQUIRED - PVC OR PLASTIC LETTER 10/24 ALUM, STUD 3" LONG INSTALLED WITH SILICONE. (4) PER LETTER WALL 6'-10 1/8- p tical 18" CAPS `- 14" LOWER CASE HELVETICA MEDIUM STUD MOUNT PLASTIC LETTERS � 18" OPTICAL SIGN N T 10.25 SO. FT. -Hr. P pto18" CAPS LOWER CASE 3 18" 1-HR. PHOTO SIGN N.T.S. i 6.5 S0. FT. Pharmac t y 18" CAPS ` 14" LOWER CASE HELVETICA MEDIUM STUD MOUNT PLASTIC LETTERS 5 18" PHARMACY SIGN N.T.S. t4.56 S0. FT. 13'-4 3/4" Vision Center 18" CAPS �- 14" LOWER CASE HELVETICA MEDIUM STUD MOUNT PLASTIC LETTERS 2 18" VISION CENTER SIGN N.T.S. 20. t 0 S0. FT. 15'-5 1/2" PharmacyDept 18" CAPS ` 14" LOWER CASE HELVETICA MEDIUM STUD MOUNT PLASTIC LETTERS 4 18" PHARMACY OEPT. SIGN N.T.S. 23.19 SO. FT. 1/8" FORMED PLASTIC LETTER 1/8" X 4" THREADED STUD IN 1/4" DRILLED HOLE FILLED W/ SILICONE FTTERS ON SPOT -FACE 6 SIGNAGE SECTION N T NOTE: DRAWINGS ON SHEET NOT TO SCALE. ANCILLARY SIGNING 09-15-00 D-1 ON SPACING DIMENSIONS TRANSLUCENT SYSTEM �J I N T �- TRANSLUCENT PANEL 146 SO. FT. QSECTION AT JAMB N.T.S. ALUM. MULLION FRAME AND COVER - ALUM. PERIMETER CHANNEL COVER SILICONE SEALANT ALL AROUND SHIM- 3/4" THICK x 2 1 /2" WIDE x 1 1 /2" HIGH ALUM. SHIM - COLOR TO MATCH ALUM. FRAMING 1 1/2" x 3/8" THICK HORIZONTAL - MULLION ATTACHED TO EACH VERT. MULLION OF TRANSLUCENT SYSTEM REMOVE AND REPLACE EXISTING - FASTENERS WITH LONGER FASTENERS TO MATCH EXISTING DIAMETER AND TYPE L SUPERCENTER SIGNING ALWAYS �WA15*UV AR7 09-15-00 B-5 NOTE: DRAWINGS ON SHEET NOT TO SCALE. 2C'-2" 0o Center I N 30' CAPS 23 1/2" LOWER CASE HELVETICA MEDIUM STUD MOUNT PLASTIC LETTERS SPACING DIMENSIONS N.T (50.47 SO. FT.) 17'-9" ow Prices 30" CAPS `— 23 1/2" LOWER CASE 3 aa. SPACING DIMENSIONS N T. S J/Bakeryt Deli t Meat Produc �1S" CAP "\- 14" LOWER CASE (10.25 SO. FT.) (5.30 SO. Fr.) (6.84 S0. FT.) (11.88 SO. FT.) NT 2 SPACING DIMENSIONS PATTERNS PROVIDED 27'-3 1/2" e Sel! For Less N 30" CAPS 23 1/2" LOWER CASE HELVETICA MEDIUM STUD MOUNT PLASTIC LETTERS 4 SPACING DIMENSIONS N T (68.20 SO. FT.) tTl-Fi/8" FORMED PLASTIC LETTER /8' X 4" THREADED STUDIN 1/4" DRILLED HOLE FILLED W/ SILICONE ACE 5 SIGNAGE SECTION N.T. 29'-3 1 /2" SUPERCENTE i M HELVETICA MEDIUM WITH 15' SLANT NOTE: SUPERCENTER STOREFONT 6 SPACING DIMENSIONS STUD MOUNT PLASTIC LETTERS SIGNAGE ONLY N T. (87.90 S0. FT. / 61 STUDS) NOTE: DRAWINGS ON SHEET NOT TO SCALE, SUPERCENTER SIGNING YY 09-15-00 B-1 (392 SO. FT.) L 4 _7. L m ----------- ---- -1 1� 56,-0" NOTE" INDIVIDUAL LETTERS ARE INTERNALLY LIT SPACING DIMENSIONS NTS 392 S0. FT. PAINTED .071 ALUM SIGN RETURN - WHITE OR RED ACR FORMED SIGN FACE PAINTED ALUM. FACT EXTRUSION RETURN SEALANT ALL SIDES 1/2" X 4" SLEEVE ANCHOR FLUORESCENT TUBING MOUNTED ON ALUMINUM WIRING TRACK (ALL ENCLOSED WIRING) FLUORESCENT LIGHT BALLAST FURNISHED BY WAL-MART SIGN SHOP 3/8" FLEX CONDUIT 5' LONG SUPPLIED IN LETTER, STUBBED THROUGH AND CAULKED BY SIGN INSTALLER 4"x4" JUNCTION BOX SUPPLIED AND INSTALLED BY GENERAL CONTRACTOR'S ELECTRICIAN �17'-0" SIGNAGE SECTION NTS. CAULK TCP OF ALL LETTERS PAINTED ALUM. FACIAL EXTRUSION RETURN - PAINTED .071 ALUM. SIGN RETURN WHITE OR RED ACRYUC FORMED SIGN FACE - DOUBLED .080 ALUM. BACK ® MOUNTING LOCATION DRYVIT SYSTEM 2x4 METAL STUDS ® 4'-0" O.0 BY BLDG. CONTRACTOR SIGN ATTACHED TO BLDG. WITH 3/8" STAINLESS STEEL 30LTS AND WASHERS FRONT AND BACK FLUORESCENT TUBING MOUNTED ON ALUMINUM WIRING TRACK (ALL ENCLOSED WIRING) FLUORESCENT LIGHT BALLAST FURNISHED BY WAL-MART SIGN SHOP 3/8- FLEX CONDUIT 5' LONG SUPPLIED IN LETTER, STUBBED THROUGH AND CAULKED BY SIGN INSTALLER 4"x4" JUNCTION BOX SUPPLIED AND INSTALLED BY GENERAL CONTRACTOR'S ELECTRICIAN 3 7'-0" SIGNAGE SECTION N T S NOTE: DRAWINGS ON SHEET NOT TO SCALE. 7'-0" WAL•MART LIT LETTERS 09-15-00 A-1 56' WAL*MART 7' INTERNALLY ILLUMINATED CHANNEL LETTER WITH WHITE FACES. INSTALL WITH'/2' X 4" RED HEAD FASTENERS, FOUR PER LETTER. WIRE TO PRIMARY BY OTHERS 392 SQ. FT. 20' 2" 17' 9" 3o,,, Food Center 3o"= Low Prices 30" WHITE FORMED PLASTIC LETTERS INSTALLED 30" WHITE FORMED PLASTIC LETTERS INSTALLED WITH STUDS AND 3UCONE 44.38 SQ. FT. WITH STUDS AND SILICONE 50.47 SQ. FT. 29" 27' 3.5" T 30" We Sell For Less 3� - _ 30" WHITE FORMED PLASTIC LETTERS INSTALLED 68.20 SO. FT. 36" YELLOW FORMED PLASTIC LETTERS INSTALLED WITH STUDS AND SILICONE WITH STUDS AND SILICONE 87.00 SQ. FT 2x 1 • RED PC ED PLASTTC LETTERS INSTALLED ON OtAES SLOG" VKTH ALW1. EAR. 146.00 SO. FT. 10.25 SQ. FT. 5.3 SQ. FT. 6.84 SQ. FT. 11.88 SQ. FT. 6' 10" 3' 6" 45 799 7' 1199 18" = Bakery Deli Meat Produce 18" WHITE FORMED PLASTIC LETTERS INSTALLED WITH STUDS AND SILICONE 9' 8.5" _ 11' 61101, 18"_ Pharmacy 18" : 1-Hr. Photo 18"__ Optical 19' WHITE FORMED PLASTIC LETTERS INSTALLED WITH STUDS AND SILICONE 18" WHITE FORMED PLASTIC INSTALLED PL WARE FORMED PLASTIC LETTERS INSTALLED 14.56 SQ. FT. WITH STUDS WITH STUDS AND SILICONE 16.50 SQ. FT. WITH STUDS AND SILICONE 1025 SO. FT. FILE NAME - WALMLEES DATE PREPARED - 12/7/98 SINCE ,Po, FIOB/DA SION COMPANx AMPS REQUIRED - ,,0,29THAYE.W. SRADENTORFL 34205 PH.ry4,1:4Ta000� s n: Feb 08 02 02:57p Ratimond Harris and Rssoc. 21474OUGOI P.1 i FES-00-2002 13;41 SE'NC141ARK GRMF 1 479 636 96Er P.61 I. TO: RAYM014D HAMS �dc,,ASSOCIATTS ARCHITECTS PROJECT, WAI,-MART # 21 R NORTH RXCOAO S' MZT SUITE 222 DATE: Z l f d DALLAS,TX'15202 FAX (214) 7494601 ATTM. WILLJAMRICEVJMON , WE ARX SENDING YOU THE FOLLOWING, sORa a f 7(i Number of pages inefaadibg cover $but: REMA MS: PAIZI r#Ai . Rev,Y'rad fl"Oviv ra I LD O'k 1✓ JLARRV E. JONES 121 WEST WALNUT, ROG10EtS, ARKANSAS 72756 1-800-3x1-8.'Ml :SQ1-63fr5Q04 FAX: 50163"687 r: G abed :Wdtrtr £ ZG 9 qad :88988490LL "ONI `8MV1 �i N0143NNId :A8 }uaS � s SCALE; t18,.=� -a" 12_L8.9 Yr�lE-tL`20L ,W,-�-% ro r A J A ED Q 01 v a iV s r iz,54 I ENTIRC -BOTH CURTESY DESK I TYP16.t47 E WOW AT B"AFF . ROUTE ALL CONDUIT CONCEALED AT BASE OF CABINET. 'COGROINATE CASH RECISTER LOCATIONS WITH cmSTRUCTION MANAGER PAY LIB-1 BANK PHONE i.Y-4 +42' #AOw EDIT IRE ccT LIB--7 �-� TY L:B- _Z-\� 16.975 LIB-5,7 ..I9=4 :;',� v._.,�, - �►r ,.mow._ � 1 lip 4~ ` FLUSH kd0�iN —47 iN CEILING 1/2"C W ETH PULL LI13-2.4 WIRE TO TELEPHONE L Y-46 BOARD IN ELECTRICAL ROOM #2. TERMINATE EACH END WITH BUSHING LIB-6.8 PANEL LIB LY-46.46 16.975 TY P L2r-2,4,6 NIOV ENTIRE L7.P-4,6 LLF-6 4CT—RL L 4 16.201 Ea.s C.3 CUURTESY �E�� P��ER�PA�SCALE: 1/8°=1�-O" 7.13.0 W '-7 - - : Z 0 - - -. - - rn C m jK} t20 zay. 3Pa�,.- 40 L p���y PANEL T�ANELC3tilARD IMA M.I-ff r FURNISHED BY SEER ta.oa r I $E rs - BANK _ BAR LOCIMOW &9NK ISOLATED gt(XM BAR ' ----- FLUSH fs OLWT acvh ( 9CttIPTdt)N % _ PL 9WR DESCRIPTION m A ` 1 I.G. RECEPTACLE 1 0261 Q. c 1 2D SPARE 2 3 RECEPTACLES 20 1 �a.72 0.06 t ZO SPARa { 5 7 RE W TACLES RECEPTACLES - 2G I 0. 72 0.00 1T 20 SPARE 6 4 SPARE 120 1 20 t 0.721 0. 1 20 SPARE B 11 SPARE 20 1 17.0@ C.00 — 1 2O SPARE t0 � V i3 SFaACE A PROYaSIC 0.0b O.Ofl 0.00 0:C0 1 20 SPARE 12 y o IS SPACE 3 PROVISloft 4;Ofl O.DO SPAt- & PRMS1697 14 c, t7 SPACE APfiO+/ SItINS SPACE & PROVISIONS t$ m 19 DACE A PR{71!ISIg s O:OQ 0.00 O:QO O.00 SPACE & PROVISIONS 4B 2t sPaCL A PROtirasltlhts 4.t>O } 0.00 SPACE 8 PROfiI5I0NS 20 23 SPACE A PROVISIONS SPACE t PR(7PISIONS 22 27 `27 ; DACE A �Rt0YMOM SFAtE 8� P�tiSIOt� _ 0.00 0.00 0.00 O.Od SPACE A PROVISIONS SPARE k PMVISIMI 21 2E � 0.{)0 0.00 SPACE � 29 SPADE & PRtWISICN s & PAOY]SIOt1S 28 TOTAL 0.00 b_00 SPACE A MOVISTONS, 3A I.03 0.72 0.72 I[VA TOTAL LOAD ®:OO 2.32 6.OD 9NA 9.00 Mas i m PER NEC ARTLCLE 22C FEEDER LOAD 2.52 WAL 6`04 k1pS ; W Il I N I I � U"7 � f ; n y III 4#410,104GR. (1 - 2 1/2"C, 4-300KCMIL AL. MAL GR) - , .343. 3##1/0.1#sGRliy i (I - 1 1 /2" C, 225 ' 343/0 AL, 1 1#4AL GR) i so 1 TY f 75KVA 4 6 E4 E4 = ##2CU 2 - 2°C,4#1/0. 1 1 1%4a C. 1#4 IG, EACH 4##33, 1#8GR" 1##8 IG, Ll (z-2c, (1'- 1 1/24C, 4#1 AL,1#6AL GR, 1 a#�/o AL, 1#6AL IG) 300 } 1#2AL GR, 1#2AL IG EACH) l i 0� 4#3, 1#BGR, 1#S IC, IN EXISTING 2 % LT51 I L 113 100 10b 1 TENANT BANK V SPACE i j� t t8.963 ELECTRICAL l 16.�ss ROM #2 1"C,4#S 1#10 CR,1#10 IG (1 - I 1/4"C, 4#4AL ,1 ##6AL GR , 146AL ICE URNISH AND INSTALL " EMPTY CONDUIT WITH ULL WIRE FOR FEEDER O PUTURE BANK 3/4"C,3#8: 1#8CR 611 1, &6J TP 15KYA #8cu s4 , NO E0l WITHIN J OF TRA SECONO LP 1"C,� 60 1 ##10 (1 - 4#4AL 1 #6AL PHARMACY 50' d L996 9L'9 6Lb T dt102f3 ?IatiNH�Pl3H �� =£T Z60Z-8F3�83� _ , _... .��-. ... ,�.. .•.-. .w ..� . o„ r.,,r. ,.,Co" ..inn •-in 9;9 abpj !Wd9b E 0 8 9a3 '•98988190LL '•'aNI 'SMV� 5 NCla3?NId :A8 �ueS $� . s 1 1 CITY OF SANFORD FIRE DEPARTMENT FEES FOR SERVICES PHONE # 407-302-1091 * FAX #: 407-330-5677 9 rA DATE: U � t - -)�-A BUSINESS NAME / PROJECT: ADDRESS: PHONE NO.(-<'G �1 a 97 AX NcSC7 / ) a73 Rb CONST INSP. [ ] C / 0 INSP.:[ ] REINSPECTION [) PLANS REVIEW F. A. [ F.S. ] HOOD [ ] PAINT BOOTH [) BURN PERMIT [ ] TEN ERMIT I ] TANK PERMIT [ ] OTHER [ ] TOTAL FEES: $ (PER UNIT SEE BELOW) COMMENTS: Address / Bldg. # / Unit # Square Footage Fees per Bldg. / Unit 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. Fees must be paid to Sanford Building Department, 300 N. Park Ave., Sanford, Fl. 32771 Phone # -407- 330-5656. Proof of Payment must be made to Fire Prevention division before any further services can take place. I certify that the above is true and correct and that I will comply with all applicable codes and ordinances pf the Cyty of Sanford, Florida. 7:z= Sanford Fire Pre ntion ivision plic is Signature 09/05/2001 12:06 501-273-6667- WAL-MART ALARM ENGRG PAGE 02 8-07-201 3=35AM FROM RECEIVED A c P I SEp 2 L 2001 CITY OF SANFORD ELECTRICAL PERMIT APPLICA ON permit Number. I — 5CG 3 Date: Z 1 The undersigned hereby applies for a permit to install the tolbwing electrical: 0., ^a r _ ��a rrh •�u i 5•�o n Ownefs Name:' owe n C -� ai_ Ar S' re a Address of Job: r- Ejecuicai Contractor. v� A ���-t D • ✓ i 6 ,\o ResideatiaL Nan -Residential: By Signing this application I am stating tnat.l am in compliance with City f Sanford Eledrlcal Code. Applicant' Si/gnu ^I'e/ State license Number w a i i o r Sanford, fo G� id, Building Department P.O. Box 1788 - 32772-1788 Telephone (407) 330-5656 Fax.( 407) 330-5677 SEP 2 6 2001 i September 19, 2001 e Wal-Mart Stores Inc. 347 Powell Dr. Lancaster, PA 17601 Dear Mr. Renkawitz, cannot accept this $50.00 check for permit fees until your permits are issued. We do not charge a plan review fee for submittal. We will advise you of the permit fees after the plans have been reviewed. do need some licensing information. You have included your state license and your liability insurance, however if you do not have a -current occupational, license for another jurisdiction in the state of Florida, we will charge -a $10.00 registration fee. We would appreciate you completing a new contractor registration form since you havenThad an active License with us since 1992. 1 have enclosed the form for you to complete. If you have any questions regarding this request, please contact me at (407) 330-5660. ,- i Sincerely, Jo -Ann M. Johnson Permit Technician "The Friendly City'► SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772 (407 302-1022 / FAX (407) 330-5677 Pager (407) 918-0388 s RevW Sheet Date: September 28, 2001 Business Address: 3653 S. Orlando Drive (Store 857) Occ. Ch. 24; Mercantile Business Name: Wal/Mart Store # 857 Ph. (407) 321-1371 Fire Alarm Contractor: Wal- Mart Alarm Central Ph. (501) 273-8402 Fax (501) 273-6867 Reviewed [ ] (pReviewed�with comment [ X)] Rejected Reviewed by: Timothy Robles, Fire Protection Inspector/Plans Examiner l + � lans tevrewed as Merca idle Occupancy (L:S C Chp #2�4) Comment: P Fire Alarm System: Plans received and reviewed. Permitting and inspections required. Application — New Building addition to existing Wal- Mart department store. #1> Fire Department will field verify constantly attended location site #2>-Fire-Department wilhrequiremorie"Pull Station"and•"Horn Strobe"War service desk perm N.F.P.A. #72- 3-8-3.1.2. 1999 edition #3>EDp.Kid�rarfartmureineostructure near fire sprinkler room #4. Fire Department will field verify ambient sound and pitch of flashes on all visual alarms devices #5> Last appliance receiving current will be tested for proper amps. Per plans submittal 1 SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, FI. 32771 / P. O. Box 1788, Sanford, FI.32772 (407 302-1022 / FAX (407) 330-567 _ Pager (407) 918-0388 �D #6>Plans do6-6-1-9If w:placemenER f re 14rinkler flow switches #7>:7hans do not show fire sprinkler -tamper- switches----i 4 ALARM CENML> I so,•n�.�soo • h— WAL-MART STORES, INC ALARM CENTRAL DIV. #0610 ' PHONE 501-273-8402' FAX 273-6867 1105 S.E. 5TH STREET' BENTONVILLE, ARKANSAS 72716-0610 AHJ Hotline to the Systems Engineering Team 1-800-530-9924 Option 3 AUTHORITY HAVING JURISDICTION Tim Robles Sanford Fire Dept 300 North Park Ave Sanford FL 32771 Phone 407-302-1091 x2052 FAX 407-330-5677 Tuesday, September 18, 2001 Store #:. 857 Facility Type Super Center Project Type: EXPANSION Address - site: 3653 Orlando Drive City - site: Sanford State - site: FL AHJ's Point -of -Contact on the Systems Engineering Team is Debra Ward 1-800-530-9924, Option 3 II' Dear Code Official; The attached "site -specific" fire alarm documents, for the above referenced project, are submitted for i - review and approval. If no approval is required, please notify the "point -of -contact" indicated above and keep these documents as a courtesy copy for your records. Wal-Mart Stores - Alarm Central Division is committed to maintaining our spotless history of life safety from fire - in well over 3000 buildings - for our Associates and the citizens of your jurisdiction. Our objective is to provide a fire alarm system that is 100% compliant with all legally enacted and adopted codes, standards, ordinances and other applicable requirements. Previously - in our "PRE -PLAN" process - we initiated steps designed to help us determine the State and/or Local modifications in your jurisdiction, and that DIFFER (if any) from the nationally published codes and standards of NFPA, BOCA, ICBO and SBCCI which we use. The attached submittal should reflect those modifications. In the event that you should determine that changes (if any) are needed regarding the attached submittal, we request that each of your review comments specify the code document, edition (yr) and numerated paragraph provision therein which is the basis for your determination. This will assist us - internally - in substantiating any increased budgetary expenditure caused by the cited change(s), and will be necessary in order to obtain authorization. All of us at the Wal-Mart Alarm Central, look forward to working with you on this project! The Systems Engineering Team e By: i - Sanford Fi e r Dater L. Ward I. R •ns Specialist NAL*­ tic, event'on Dig►. = STORES', llvc . Phone: . 50f-273-8402 Alarm Central '1 FAX: 501-273-¢867 `" -110.5 Southeast.5th St. Voice Mail;`501-273-8800 Ext. 55500 Bentonville, AR 727'16-8091 WAL*MART - ELECTRONIC FIRE PROTECTION SYSTEM - PROJECT DOCUMENTATION s� Summary of Applicable Requirements Based Upon The STANDARD FIRE AND BUILDING CODES as published by the Southern Building Code Congress International (SBCCI) Also applied where a State or locally adopted code is based upon these requirements. 1) This is a GROUP M (Mercanitle) Occupancy Classification per B310.1, with ordinary contents for this class. 2) The building shall include complete automatic fire SPRINKLER protection throughout per B903.7.1 3) The sprinkler system shall be electronically supervised and connected to the building fire alarm system per 13903.8 4) Manual stations are not required per F603.7.2 and per B905.1.1 Exception 2. 5) Occupant notification will be provided in accordance with B905.1.5 See Tab #2 of the submittal package for details. 6) One manual station will be provided at the constantly attended location as required by NFPA 72, 3-8.3.1.2 ('99). 7) One smoke detector will be provided to protect the CPU ("FACP") as required by NFPA 72, 1-5.6 ('99). 8) Where automatic extinguishing systems (ANSUL, etc) are provided within this project (if any) they will be connected to initiate an "Alarm" condition per NFPA 72, 2-7 ('99). 9) Wiring shall be PLFA (Power Limited Fire Alarm) cabling (Listed "FPL') installed in accordance with the applicable requirements of NFPA 70, The National Electric Code, specifically including Articles 760-52 (b) and 336-18. SEE "AHJ / COMPLIANCE NOTES" ON SHEET EFP-1 FOR ADDITIONAL DETAILS. NOTE: In the event that any State or local amendments have been legally adopted in your jurisdiction and where such amendments are contrary to the nationally recognized code first set forth above, please provide a copy of the applicable provisions to Wal*Mart Alarm Central along with your review comments. REV091500 ,,. i i Southern Building Code Congress International :.. Inc. scn�r*it tr,e Stanaaro for President and °MV='s kroner Codes Chairman of the Hoard Nick D'Andre"a. Jr.. CBO Manager. Commercial Development Sarvicss January 19, 2000 Tampa, Florida Vice Presiders Wigiam L. Duck, Jr., CaO ` Michael Minieri, li, Manager Chief of'Inspe�cnens and Code System Engine 2ring & )ndUstry Affairs Enforcement DivisionColumbus. Gcargie Alarm Central 1105 S_E. 5'*' Street Board of Directors Warty Bailey, Ciao Bentonville, AR 72716-8091 Director, "peveiopment and - Construction ° VIA FAX 501 273-6867 Fan Smith Arkansas - Frank P. bodge, Jr., C80," CSAP RE 1997 Edition - Standard Fire Prevention Code Director. Building and Fire Codes I filton'Head Island, South Carolina Section 603.7-2 ' + C. Curtis Mann, PE, C80 Dear Mr. Minieli: Cniaf Bum Official Now Ontaans. Louisiana Section 603.7.2 in m opinion iS a poorly Written provision. This Section should be written as y � p � P Donny Phipps, CeO oireaa o1 Inspection -- a second exception to section 503.7.1. in otherwords-the provision should be. Calurnbia. South Carolina. ' 603.7.1 A manual firs alarm system complying with the requirements of NFPA 72 shall be Dominic Sims: C80 Executive Director installed in all of the fallowing occupancies: Palm Baach Courtly, Florida ; ° 1 2..,. lmmeedfara Past President # Larry BAIL; 3 Budding Director I 4..:. - Starkville, Mississippi 5.... Chief Executive Officer - 6... Mfliam J: Tangye, PE I 7... Headquartars Office" — 8..._ 900 Montciair Goad. ° 5irmingt�inl,` Alat�ama ° Exception 1. Where each guest room or apartment has a direct exit to the outside of the 35213-1206` 205-591-1853 ' building and the building is three stories or less in height Fax2os•592-7oot - TDD: 2C5-599-97'42 " Exception 2 In buildings equipped with an automatic firs detection system or automatic Eastern Regional Office sprinldei system covering all areas- 1200 W00drUff rR=tL Suite G-26 ° arieer ville, South Carotma 29607-9443 Actuation of the automatic fire detection system or automatic sp rinideer system shall sound 864-281-1006 a 4 n mtema! evacuation alarm- Provision shall be made to manually activates th® internal Fax e64-2e1 1a3o evacuation alarm at a minimum of one centrally located station. southeast Regional orrice 4303 Vineland Road, Suite F-7 Ortando, Florida 32811 - 407-648-9632 Far 407-60-9702 Southwest Regional trtrice 9d20 Research Boulevard Echelon ill, Suite 150 Austin, Taxis 78752 512-346-4150 -- Fax:512.346-4227 -- Toll tree order numbor- (BM) 44-WCCI • Honk pagw httpJlwwwAbeti.org E-mail: info®ebcci.om L i Mr. Michael Minieri, II Page 2 The way the code is currently written, the word "may" means that, you don't have to install manual pull stations, but if you do it's OK If the Cade Official is requiring pull stations in this sihiation, it is being done outside the scope of Section 603.72 I am pleased to provide you with the opinions stated herein. It should be noted, however, that the final . interpretation is that of the code official. Sincerely, I! _' Mel Cosgrove Fire Code Anaiyst ,! MClas ;I I i STORE #857 PSI LP1 August 08, 2001 09:49 AM Fire Alarm Panel Specifications: Panel Voltage = 24V; Panel Current = 2A; Allowable Percent Degradation = 10% # Dev Company Name Device Model Number DevCur AWG Dist VDEV IDRAW;.RLDEV RLOOP Fire Alarm Panel 24. 1 1 Custom PC2475 (W-75-HS) .15 12 47 23.87 .15 0.15228 0.15228 2 2 Custom PC2475 (W-75-HS) .15 12 80 23.68 .3 0_2592 0.41148 3 3 Custom PC2475 (W-75-HS) .15 12 108 23.48 .45 0.34992 0.7614 4 4 Custom PC2475 (W-75-HS) .15 12 86 23.36 .6 0.27864 1.04004 5 5 Custom PC2475 (W-75-HS) .15 12 302 23.09 .75 0.97848 2.01852 6 6 Custom SC2475 (W-75-S) .127 12 90 23.05 .877 0.2916 2.31012 STORE #857 PSI LP2 August 08, 2001 10:44 AM Fire Alarm Panel Specifications: Panel Voltage = 24V; Panel Current = 2A; Allowable Percent Degradation = 10% # Dev Company N4pe Device Model Number DevCur AWG Dist VDEV IDRAW RLDEV RLOOP Fire Alarm Panel 24. 1 1 Custom PC2475 (W-75-HS) .15 12 35 23.84 .15 0.1134 0.1134 2 2 Custom SC2475 (W-75-S) .127 12 57 23.61 .277 0.18468 0.29808 3 3 Custom SC2475 (W-75-S) .127 12 44 23.45 .404 0.14256 0.44064 4 4 Custom PC2475 (W-75-HS) .15 12 39 23.32 .554 0.12636 0.567 5 5 Custom SC2475 (W-75-S) .127 12 50 23.18 .681 0.162 0.729 6 6 Custom PC2475 (W-75-HS) .15 12 50 23.06 .831 0.162 0.891 7 7 Custom PC2475 (W-75-HS) .15 12 30 23. .981 0.0972 0.9881999 8 8 Custom PC2475 (W-75-HS) .15 12 102 22.86 1.131 0.33048 1.31868 9 9 Custom SC2475K (W-75-S-WP) .127 12 121 22.75 1.258 0.39204 1.71072 10 10 Custom PC2475 (W-75-HS) .15 12 30 22.74 1.408 0.0972 1.80792 STORE #857 PSI LP3 August 09, 2001 12:57 PM Fire Alarm Panel Specifications: Panel Voltage = 24V; Panel Current = 2A; Allowable Percent Degradation = 10% # Dev Company Name Device Model Number DevCur AWG Dist VDEV IDRAW RLDEV ' RLOOP Fire Alarm Panel 24. 1 1 Custom PC2475 (W-75-HS) .15 12 542 22.68 .15 1.75608 1.75608 2' 2 Custom PC2475 (W-75-HS) .15 12 83 22.52 .3 0.26892 2.025 3 3 Custom PC2475 (W-75-HS) .15 12 75 22.41 .45 0.243 2.268 4 4 Custom PC2475 (W-75-HS) .15 12 77 22.34 .6 0.24948 2.51748 5 5 'Custom PC2475K (W-75-HS-WP) .15 12 43 22.32 .75 0.13932 2.6568 AlarmSaf 65A Industrial Way, Wilmington, V MA 01887-3499 (508) 658-6717 FAX: (508) 658-8638 Web Site: www.alarmsaf.com STORE #857 PS1 LP4 August 08, 2001 11:14 AM Fire Alarm Panel Specifications: Panel Voltage = 24V; Panel Current = 2A; Allowable Percent Degradation = 10% # Dev Company Name Device Model Number DevCur AWG Dist VDEV IDRAW RLDEV RLOOP Fire Alarm Panel 24. 1 1 Custom PC24177 (C-177-HS) .314 12 315 22.72 .314 1.0206 1.0206 2 2 Custom PC24177 (C-177-HS) .314 12 86 22.46 .628 0.27864 1.29924 3 3 Custom PC24177 (C-177-HS) .314 12 98 22.26 .942 0.31752 1.61676 4 4 Custom PC24177 (C-177-HS) .314 12 81 22.18 1.256 0.26244 1.8792 STORE #857 PS2 LP1 August 08, 2001 11:22 AM Fire Alarm Panel Specifications: Panel Voltage = 24V; Panel Current = 2A; Allowable Percent Degradation = 10% # Dev Company Name Device Model Number DevCur AWG Dist VDEV IDRAW RLDEV RLOOP Fire Alarm Panel 24• 1 1 Custom PC24177 (C-177-HS) .314 12 657 21.99 .314 2.12868 2.12868 2 2 Custom PC24177 (C-177-HS) .314 12 97 21.79 .628 0.31428 2.44296 3 3 Custom PC24177 (C-177-HS) .314 12 125 21.66 .942 0.405 2.84796 STORE #857 PS2 LP2 August 08, 2001 01:10 PM Fire Alarm Panel Specifications: Panel Voltage = 24V; Panel Current = 2A; Allowable Percent Degradation = 108' # Dev Company Name Device Model Number DevCur AWG Dist VDEV IDRAW RLDEV RLOOP Fire Alarm Panel 24• 1 1 Custom PC24177 (C-177-HS) .314 12 280 22.86 .314 0.9072 0.9072 2 2 Custom PC24177 (C-177-HS) .314 12 94 22.57 .628 0.30456 1.21176 3 3 Custom PC24177 (C-177-HS) .314 12 125 22.32 .942 0.405 1.61676 4 4 Custom PC24177 (C-177-HS) .314 12 92 22.23 1.256 0.29808 1.91484 STORE #857 PS2 LP3 August 08, Panel Voltage = 24V; 2001 01:21 PM Panel Current = 2A; Allowable Percent Degradation = 10% Fire Alarm Panel Specifications: Device Model Number DevCur AWG Dist VDEV IDRAW RLDEV RLOOP # Dev Company Name Fire Alarm Panel 24• PC24177 (C-177-HS) .314 12 162 23.34 .314 0.52488 0.52488 1 1 Custom PC24177. (C-177-HS) .314 12 85 23.08 .628 0.2754 0.80028 2 2 Custom PC24177 (C-177-HS) .314 12 200 22.67 .942 0.648 1.44828 3 3 Custom PC24177 (C-177-HS) .314 12 92 22.58 1.256 0.29808 1.74636 4 4 Custom AlarmSaf t 65A Industrial Way, Wilmington, MA 01887-3499 (508) 658-6717 FAX: (508)i658-8638 Web Site: www.alarmsaf.com STORE #857 PS2 LP4 August 08, 2001 02:25 PM Fire Alarm Panel Specifications: Panel Voltage = 24V; Panel Current = 2A; Allowable Percent Degradation = 10% # Dev Company Name Device Model;'Number DevCur AWG Dist VDEV IDRAW RLDEV RLOOP Fire Alarm Panel 24, 1 1 Custom SC2475 (W-75-S) .127 12 531 22.57 .127 1.72044 1.72044 2 2 Custom PC2475 (W-75-HS) .15 12 68 22.41 .277 0.22032 1.94076 3 3 Custom PC2475 (W-75-HS) .15 12 102 22.23 .427 0.33048 2.27124 4 4 Custom PC2475 (W-75-HS) .15 12 43 22.17 .577 0.13932 2.41056 5 5 Custom SC2475 (W-75-S) .127 12 24 22.15 .704 0.07776 2.48832 6 6 Custom SC2475 (W-75-S) .127 12 18 22.14 .831 0.05832 2.54664 STORE #857 PS3 LP1 August 08, 2001 02:40 PM Fire Alarm Panel Specifications: Panel Voltage = 24V; Panel Current = 2A; Allowable Percent Degradation = 10% # Dev Company Name Device Model Number DevCur AWG Dist VDEV IDRAW RLDEV RLOOP Fire Alarm Panel 24. 1 1 Custom PC24177 (C-177-HS) .314 12 157 23.2 .314 0.50868 0.50868 2 2 Custom PC24177 (C-177-HS) .314 12 88 22.84 .628 0.28512 0.7938 3 3 Custom PC24177 (C-177-HS) .314 12 199 22.23 .942 0.64476 1.43856 4 4 Custom. PC24177 (C-177-HS) .314 12 93 22.04 1.256 '0.30132 1.73988 5 5 Custom PC24177 (C-177-HS) .314 12 80 21.96 1.57 10.2592 1.99908 STORE #857 PS3 LP2 August 08, 2001 02:58 PM Fire Alarm Panel Specifications: Panel Voltage = 24V; Panel Current = 2A; Allowable Percent Degradation = 10% # Dev Company Name Device Model Number DevCur AWG Dist VDEV IDRAW RLDEV RLOOP Fire Alarm Panel 24. 1 1 Custom SC2475 (W-75-S) .127 12 653 22.51 .127 2.11572 2.11572 2 2 Custom SC2475 (W-75-S) .127 12 20 22.47 .254 0.0648 2.18052 3 3 Custom PC2475 (W-75-HS) .15 12 27 22.43 .404 0.08748 2.268 4 4 Custom PC2475 (W-75-HS) .15 12 20 22.41 .554 0.0648 2.3328 5 5 Custom PC2475 (W-75-HS) .15 12 141 22.34 .704 0.45684 2.78964 AlarmSaf 65A Industrial Way, Wilmington, MA 01887-3499 (508) 658-6717 FAX: (508) 658-8638 Web Site: www.alarmsaf.com STORE #857 PS3 LP3 August 08, 2001 03:22 PM Fire Alarm Panel Specifications: Panel Voltage = 24V; Panel Current = 2A; Allowable Percent Degradation = 10% # Dev Company Name Device Model Number DevCur AWG Dist VDEV IDRAW RLDEV RLOOP Fire Alarm Panel 24. 1 1 Custom PC24177 (C-177-HS) .314 12 260 22.82 .314 0.8424 0.8424 2 2 Custom PC24177 (C-177-HS) .314 12 88 22.51 .628 0.28512 1.12752 3 3 Custom PC24177 (C-177-HS) .314 12 80 22.31 ..942 0.2592 1.38672 4 4 Custom PC24177 (C-177-HS) .314 12 98 22.16 1.256 0.31752 1.70424 5 5 'Custom PC2475 (W-75-HS) .15 12 222 22.05 1.406 0.71928 2.42352 STORE #857 PS3 LP4 August 08, 2001 04:04 PM Fire Alarm Panel Specifications: Panel Voltage = 24V; Panel Current = 2A; Allowable Percent Degradation = 10% # Dev Company Name Device Model Number DevCur AWG Dist VDEV IDRAW RLDEV RLOOP - Fire Alarm Panel 24• 1 1 Custom PC24177 (C-177-HS) .314 12 345 22.6 314 1.1178 1.1178 22 Custom PC24177 (C-177-HS) .314 12 99 22.3 .628 0.32076 1.43856 3 3 Custom PC24177 (C-177-HS) .314 12 113 22.07 .942 0.36612 1.80468 4 4 Custom PC24177 (C-177-HS) - .314 12 86 21.98 1.256 0.27864 2.08332 STORE #857 PS4 LP1 August 08, 2001 04:17 PM Fire Alarm Panel Specifications: Panel Voltage = 24V; Panel Current = 2A; Allowable Percent Degradation = 10 # Dev Company Name Device Model Number DevCur AWG Dist VDEV IDRAW RLDEV RLOOP Fire Alarm Panel 24• 1 1 Custom PC24177 (C-177-HS) .314 12 641 22.07 .314 2.07684 2.07684 2 2, Custom PC24177 (C-177-HS) .314 12 92 21.89 .628 0.29808 2.37492 3 3 Custom PC2475 (W-75-HS) .15 12 84 21.81 .778 0.27216 2.64708 4 4 Custom PC2475 (W-75-HS) .15 12 100 21.76 .928 0.324 2.97108 AlarmSaf 65A Industrial Way, Wilmington, MA 01887-3499 (508) 658-6717 FAX: (508) 658-8638 Web Site: www.alarmsaf.com .-:.0 to N1 = w N y d 'p ' O 0 O *1 L. _l 0 d C L C 0 i Qr CCA E O# a w�j 0 a OM aCi pM ID •�pMo L O V ~ 'v L Ri a'� �?,ocaa'�d aNipL c4'nd�=v�U) as �w� d ow iv N CC a'N C Cv d d Nw� = � cl NV am O I- Qd= �O "' o 0� E i Vd V o N d O O cc E O�= v -Qd � yN W Q c t`v O O (A w to V O m p_ d=W to r -p OaC C N '� U Q O~ LL O .p ? N d O C Q v N O .O 10 0i U) - ' top :° _ L V d i L. CT d cr d N L V — - C) N am. 'd V H L d 2 O c:� Ri d ^C N t O N> .� e- O C N 'Q ,� =O Q O� L O= '� C R .i . li7 d tm .� d N L. O O , to (� •� . O O 0R.°�LQOC# coON v o V Q v al� NN0'dO N � O 0)NX �C.)rO~ 3N C d K �r�°'° aw. ro- _ = °o m E a. c�o . -o MMLL oa o oL+ Mrti 6. -_ Q' 2C. w Q '� CCc d o M O N `� 4' L. ch Z O L L L Hcb<a,Pm H•vW. cc 0.E c��wA cc a. U) 0 < R H vii:Z 0 e � V U) Q U L) 0 V .N M g M Q cm a .® L O CD m V Z Wd� 1 2oa N ® , d CO V to �� �� _ d J 1 O - r S - •- 1 1 1 , 1 1 I , , 1 I 1 , 1 ' ' 1 -------------------- O O L N d r.l I Ik $ _ WAL*MART STORES, INC. - "�`ALARM CENTRAL * PHONE 501-273-8402 FAX'273-6867 SCENT 1105 S.E. 5th Street * BENTONVILLE AR 72716-8091 WHY WAL*MART DOES NOT SPACE STROBES .BASED UPON - NFPA 72, TABLE 4-4.4.1.1 j The following data shows that half (6 out of 12) of the selections permitted by the table do not comply with the technical criteria required to meet the Americans with Disabilities Act Accessibility Guidelines j (ADAAG). The ADA/FAQ requires an effective intensity of .0300 footcandles (lumens/ft2) at the maximum actual viewing distance. This is derived from calculating the inverse square law as applied to a 75cd strobe viewed at 50'. l SPACE (ft) HEIGHT (ft) STROBE (cd) INTENSITY (fc) MEETS ADA? ' 1 20x20 10 5cd .0109 NO 20x20 20' 30cd .0325 YES 20x20 30' 55cd .0334 YES I 30x30 10, 30cd .0207 NO i 30x30 20' 45cd .0392 YES l 30x30 30' 75cd .0409 YES�� 40x40 10, 60cd .0233 NO 40x40 20' 80cd .0293 NO i 40x40 30' 115cd .0344 YES 50X50 10, 95cd .0227 NO 50x50 20 115cd .0287 NO 50x50 30' 150cd .0389 YES P Notes: 1) Room size, ceiling mounting height and cd rating correspond to table 4-4.4.1.1 (b) r99] 2) Calculation using adjusted intensity for viewing angle per UL Standard #1971, table 27.3 3) Inverse Square Law formula is "candela rating" divided by "viewing distance" squared. Prepared by Michael Wm. Minieri II, Manager— Systems Engineering & Industry Affairs (501-277-2274) [Revised August 24, 2000] 1 5T o August 3, 2000 _1 i° Mr. Michael Minieri Alarm Central 702 S.W. 8" Street Bentonville, AR 72716-8091 Subject: 177 Candela Strobe Calculations -_ I Dear Mr. Minieri: Enclosed please find a series of calculations and sketches that are intended to provide -- guidance when using 177 candela strobes in areas larger than 50' Wx50'Lx30'H. As the calculations indicate, 177 candela strobes may be used in areas as large as 100'Wx100'Lx30'H and still provide 0.03 lumens per square feet light intensity. This light intensity meets the minimum light output requirements outlined in the Americans with Disabilities Accessibility Guidelines. Note that these calculations assume that the 177-candela strobe is mounted no higher than 30' above the floor, and is mounted in the center of the ceiling. Should any further questions arise, please feel free to contact us at 800-SENSOR2. i I Sincerely, s i Tom Potosnak Director of Marketing AudibleNisible & Waterflow Products e cc: John Kearle y Ken Krup System Sensor A Division of Pittway Audible/Visible and Waterflow Division 3820 Stern Avenue St. Charles, Illinois 60174 Telephone: 630-377-6580 Fax: 630-443-2590 http://w=. systeTnsensor. com i, 100' L 100, 30' H Distance Y is calculated in a similar way. By taking the square root of the sum (302 + 70.712), we find that: Y = the square root of 5900 = 76.81' Y represents the furthest distance the light must travel in this 100'x100'x30' area. According to ADA, at this furthest distance, the light intensity must be at least 0.03 lumens per square foot. Using the formula: Lumens per square foot = candela / distance2 Lumens per square foot = 177 candela / (76.81 feet)2 Lumens per square foot = 177 candela / 5900 feee Lumens per square foot = 0.03 Therefore, 177-candela strobe can be mounted in a 100'x1WOO' area, and meet the minimum light intensity required by the Americans with Disabilities Act. Note: It is assumed that the ceiling mount device is mounted in the center of the ceiling, and is located no more than 30' above the floor. 100, 100, W 177-candela strobe mounted in center of the ceiling, 30' above floor. 100' L 0 Top view of area 6111 50' 30' H X is calculated by taking the square root of the sum (502 + 502). X = 70.71' Models Available Strobe Models White Red SC2415W SC2415 SC241575W SC241575 SC2430W SC2430 SC2475W SC2475 SC2495W SC2495 SC24177W SC24177 Horn/Strobe Models White Red PC2415W PC2415 PC241575W PC241575 PC2430W PC2430 PC2475W PC2475 PC2495W PC2495 PC24177W PC24177 cessory Mounting Plates kite Red BBSCW BBSC Product Overview Lower current draw Available in 15, 15/75, 30, 75, 95, and 177 candela Horn/strobe models include a three position switch for field -selecting horn tones: Electromechanical/3 KHz Temporal 3/Non-temporal 3 High/Low dBA output Ceiling -specific shape, profile, and aesthetics Mounts to 4x4x1-1/2 back box Round shape offers greater placement -flexibility U� LISTED .SC2A.15.i5W- System Sensor's SpectrAlert ceiling mount series strobes and horn/strobes offer a fresh approach to addressing the unique needs for ceiling mount applications. Technology. Like the original SpectrAlert, the SpectrAlert ceiling mount series offer significant current draw reductions over other ceiling mount strobes and horn/strobes. Flexibility. Spectr Alerr ceiling mount strobes and horn/strobes are available in six different candelas, including 177 candela for sleeping areas. The horn/strobe's tones are field-selecrable through the use of a three position switch located on the back of the unit. Selections include electromechanical and 3 KHz tones, temporal 3 and non -temporal 3 patterns, and high and low volume. Aesthetics. SpecrrAlert ceiling strobes and horn/strobes offer a design that is sensitive to the aesthetic demands of ceiling mount applications. The round shape maintains a low profile appearance, similar to that of a smoke detector. Its SU lish curves and design further refine the aesthetics over other creneric wall/ceiling mount designs. Yer Spectr Alert's round shape provides clearly visible "FIRE" identification from all angles. Installation. SpecrrAlert's compact design also offers installation savings. The strobe and horn/strobe models mount to a 4x4x1-1/2 back box, and take up little room in the back box, making connections easier. And with SpectrAlerr's round shape, it is not necessary to align the back box with the room's walls. SpectrAlerr always lines up. System Sensor's SpectrAlert ceiling mount series strobes and horn/strobes offer a fresh approach to addressing the unique needs for ceiling mount applications. Technology. Like the original SpectrAlert, the SpectrAlert ceiling mount series offer significant current draw reductions over other ceiling mount strobes and horn/strobes. Flexibility. Spectr Alerr ceiling mount strobes and horn/strobes are available in six different candelas, including 177 candela for sleeping areas. The horn/strobe's tones are field-selecrable through the use of a three position switch located on the back of the unit. Selections include electromechanical and 3 KHz tones, temporal 3 and non -temporal 3 patterns, and high and low volume. Aesthetics. SpecrrAlert ceiling strobes and horn/strobes offer a design that is sensitive to the aesthetic demands of ceiling mount applications. The round shape maintains a low profile appearance, similar to that of a smoke detector. Its SU lish curves and design further refine the aesthetics over other creneric wall/ceiling mount designs. Yer Spectr Alert's round shape provides clearly visible "FIRE" identification from all angles. Installation. SpecrrAlert's compact design also offers installation savings. The strobe and horn/strobe models mount to a 4x4x1-1/2 back box, and take up little room in the back box, making connections easier. And with SpectrAlerr's round shape, it is not necessary to align the back box with the room's walls. SpectrAlerr always lines up. r General Specifications Dimensions 6.8" diameter SpectrAlert Dimensions -7 Mounting 4"x4"x1-1/2" back box —2.4"� T I 6.8" SpectrAlert Ceiling Mount Strobe SpectrAlert Mounting Diagrams 000 , d' d , Strobe or Horn/Strobe with Mounting Plate Electrical Specifications Operating Voltage 24 VDC and FWR unfiltered 1—,t Terminals 18 AWG Operating Voltage Range 24V, 16-33 V Indoor Operating Temperature 32° to 120° F (0° to 49°C) SpectrAlert Ceiling Mount Horn/Strobe o a Strobe or Horn/Strobe with Accessory Back Box Skirt Operating Voltage Range w/Sync-Circuit Module 24V. 17-33 V Sound Output Guide (dBA) 'mporal — Low Volume I High Volume Electromechanical 3000 Hz Interrupted Electromechanical 3000 Hz Interrupted Non- Low Volume j Electromechanical Temporal 3000 Hz Interrupted High Volume Electromechanical 3000 Hz Interrupted Current Draw Table Strobe Only 1 AVERAGE CURRENT (mA) PEAK CURRENT (mA) UL Reverberant Room dBA @ volts DC 16 75 j 24 75 33 19 75 75 j 79 79 82 82 79 1 82 82 75 82 ! 82 79 82 85 82 I 85 85 82 1 85 85 IN RUSH CURRENT (MA) Candela DC — I twv FWR DC 1 156v ! lbv FWR i. DC 1 FWR I DC I 24V FWR DC FWR I 33V OC I FWR j DC 16V FWR j 24V DC 1 FWR 33V DC FWR 15 63 56 48 55 41 51 164 232 1170 242 1701 224 91 118 133 177 188 252 15/75 75 64 56 62 47 1 62 ;174 238 172 258 168i 228 91 115 1341 179 i182! 237 30 951 75 11791 95 223 81 j 68 144 1 127 198 153 79 j 140 1 173 56 73 1238 288 1226j 1 101 126 1 418J 436 ' 398 j 122 163 ' 5401 562 1 534 318 2181 298 462 1 384 ; 486 199 560 518 i 552 , 94 92 j 116 118 115 ! 1137! 179 133 j 177 1186 132 ' 176 1187 184 244 i 238 ! 244 177 TBID1 TBDj TBD I TBD 1 TBD; TBD 1 TBD TBD TBD TBD 1 TBD; TBD TBDj TBD 1 TBD TBD 1 TBD TBD Horn/Strobe 15 cd Tone Electro- 3000 Hz Interrupt. AVERAGE CURRENT (mA) High/Low Temp 16V j 24V 33V Volume Non DC FWR DC ! FWR DC FWR High Temp. 78 1 80 1 71 j 89 70 1 94 Non. 78 i 80 71 89 70 94 Low Temp. 71 ! 69 ! 62 74 59 77 Non. 71 69 62 74 59 77 High Temp. 81 ! 83 75 1 94 76 99 Non. 81 83 75 94 76 1 99 Low Temp. 72 70 64 77 63 81 Non. 72 j 70 64 77 63 81 Horn/Strobe 15/75 cd AVERAGE CURRENT (mA) High/Low Temp 16V I 24V 33V Tone Volume I Non DC FWR OC FWR DC I FWR Electro- i High Temp. 90 88 79 96 76 ! 105 mech. Non. 90 88 79 1 96 76 ; 105 Low Temp. 83 i.. 77 70 81 65 1 88 i i 3000 Hz High Non. j Temp. 83 77 1 70 81 65 1 88 ! 93 j 91 i 83 101 1 82 1 110 Interrupt., 1 Low Noon. I Temp. 1 63 91 1 83 i 101 82 1 110 84 ' 8 62 1 84 169 92 Non. j 84 78 j 72 j 84 ! 69 92 Horn/Strobe 30 cd AVERAGE CURRENT (mA) High/Low ! Temp 16V 24V I 33V Tone Volume Non DC FWR 1 DC j FWR : OC FWR Electro- High Temp. ;110 i 105 1 91 ! 113 85 116 Non. I110105 91 113 8�5 1166 Tem 103: 94 ' 82 ' 98 7I 4 99 Low Non. 1031 94 82 98 74 1 99 �— 3000 Hz High Tem . 1113 108 95 1 118 91 121 Interrupt. Low Non. 113i 108 1 95 1 118 91 1121 Temp. `E1041 95 84 101 78 103 Non. 1 104 j 95 1 84 j 101 78 ! 103 Horn/Strobe 75 cd Tone Electro- mech. 3000 Hz interrupt AVERAGE CURRENT (mA) High/Low Temp 16V j 24V 33V Volume Non DC I FWR DC 1 FWR DC FWR High Temp. 11941 168 j 150 174 130 1 169 Non. j 194i 168 j 150 i 174 1301 169 Low ITemp. 1187, 157 141; 159 1191 152 Non. 187 157 141: 159 119 152 High Temp. 197, 171 154! 179 136 174 Non. 11971 171 154' 179 136 174 Low jTemp. j188I 158 143! 162 123 156 Non. 11881 158 j 143 162 1231 156 Horn/Strobe 95 cd ,AVERAGE CURRENT (mA) High/Low j Temp j 16V 24V 33V — Tone Volume I Non I DC I FWR OC FWR . DC I FWR Elect'ro- High I Temp. 1238j 222 j 176: 207 151 2 66 mech. Non. 2 g; 222 176. 207 151 206 Low Temp. i2311 211 167 192 140 ! 139 — Non 1231; 211 167 192 '140' 189 3000 Hz ! High Temp. 1241! 225 ! 180 212 157 .211 Interrui Non. !241. 225 180 212 157: 211 Low Temp. !232: 212 169 195 144 193 Non. !232! 212 169 195 144 193 Horn/Strobe 177 cd AVERAGE CURRENT (mA) High/Low i Temp 16V 24V 33V Tone Volume Non DC FIN DC FNR DC FWR Electro- i High Temp. TBD; TBD TBD: TBD TBD' TBD mech. I Non. 'TBD; TBD TBD., TBD TBD! TBD I Low Temp. TBD TBD : TBD , TBD TBD ' TBD I Non. !TBDj TBD i TBD' TBD . TBD i TBD 3000 Hz High Temp. iTED! TBD TBD TBD TBD TBD Interrupt.I Non. 1TBD TBD !TBD' TBD TBD TBD Low I Temp. i 'TEID1 TBD TBDj TBD : TBD TBD Non. I TBDj TBD 1 TBD 1 TBD TBD TBD Engineering Specifications Strobe Strobe shall be a System Sensor SpectrAlert Model listed to UL 1971 and be approved for fire protective service where ceiling mount strobes are permitted. The strobe shall be wired as a primary signaling notification appliance and shall flash at 1Hz over the strobe's entire operating range. The strobe shall consist of a xenon flash tube and associated lens/reflector system. Horn/Strobe Combination Horn/strobe shall be a System Sensor SpectrAlert Model listed to UL 1971 and UL 464 and be approved for fire protective service where ceiling mount horn/strobes are permitted. The horn/strobe shall be wired as a primary signaling notification appliance and shall flash at 1Hz over its entire operating range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two tone options, two audibility options, and the option to switch between a temporal 3 pattern and a non -temporal continuous pattern. These options shall be selected by a multi - position switch. Strobes shall be powered independently of the sounder with the removal of factory installed jumper wires. The horn on horn/strobe models shall operate on a coded or non -coded power supply. Note: The strobes must be powered continuously for the horn to operate. Ordering Information Ceiling Mount Strobes Ceiling Mount Horns/Strobes' ",Circuit !le Surface -mount back box skirt Model No. White Red I Voltage SC2415W j SC2415 i 24 SC241575W j SC241575 24 SC2430W I SC2430 24 SC2475W SC2475 24 SC2495W SC2495 24 SC24177W SC24177 24 PC2415W PC2415 24 PC241575W PC241575 24 PC2430W PC2430 24 PC2475W PC2475 24 PC2495W PC2495 24 PC24177W PC24177 24 MDLW MDL — BBSCW BBSC I - Candela 15 15/75 30 75 95 177 15 15/75 30 75 95 177 *Horn/strobe current draws assume horn is set at temporal 3, electromechanical tone, and high audibility. System Sensor Sales and Service System Sensor Headquarters System Sensor Canada 3825 Ohio Avenue Ph: 905.812.0767 St. Charles, IL 60174 Fx: 905.812.0771 Ph: 800-SENSOR2 System Sensor Europe Fx: 630/377-6495 Ph: 011.44.1403.276500 ents on Demand Fx: 011.44.1403.276501 736-7672 x3 www.systemsensor.com System Sensor in China System Sensor— Far East Ph: 011.86.29.524.6253 Ph: 011.85.22.191.9003 Fx:011.86.29.524.6259 Fx:011.85.22.736.6580 System Sensor in Singapore System Sensor— Australia Ph: 011.65.273.2230 Ph: 011.613.54.281.142 Fx:011.65.273.2610 Fx:011.613.54.281.172 Avg. Current (mA) @24V DC FWR 48 55 56 62 68 79 127 140 153 173 TBD TBD 71 89 79 96 91 113 150 174 176 207 TBD TBD 16 24 0 1999 System Sensor. The company reserves the right to change product specifications without notice. A05.1025.01.11; 99(5k).x515 N �'Pf CJ T n D O Z Control Unit Component Clarification ...... __... . Plan Symbol = CP SA D1256 - CP-SA The Radionics D1256 is a combination keypad - annunciator with a plain English, Alpha -Numeric display of the addressable, Point I.D. information. This component provides the user interface found at a "control panel". 0 Plan Symbol = CPU D9124 FRCP or CPU The Radionics D9124 is a blank faced cabinet housing the central processor , and circuitry. It has NO annunication and NO use interfacecontrols. The location of the CPU on the premises is irrelevant. Plan Symbol = SA D1257 - SA The Radionics D1257 is an annunciator with a plain English, Alpha -Numeric display of the addressable, Point I.D. information. This component provides NO user interface. i � iCS � TM Control Features • Eight programmable areas, each with perimeter/interior partition- ing. Regular, master, associate, or shared option by area • Real-time clock and test timer • Up to 1000-event log, including time, date and event with area, point and user number • Battery charging circuit, AC power and voltage supervision • Automatic reset circuit protectors • On -board CPU watchdog warning buzzer and diagnostic LEDs • Lightning and EMI protection • Power limited external circuits Communicator [71, • Built-in digital communicator with , phone line monitor (loop or ground start) • Multiple telephone numbers, primary and duplicate paths with main and alternate destinations • All reports within each 4 route groups are programmable • Optional dual phone line switcher monitors 2 phone lines • Automatic test and status reports • Time windows for arming and open/close report suppression • Programmable answering machine work -around for remote programming on shared phone lines Programmable Outputs • 2-amp alarm power @ 12 VDC • 1.4-amp aux power @ 12 VDC • 4 alarm output patterns • Automatic bell test • Programmable bell shut-off timer • D7212/D7412: 67 programmable relay outputs D9112/D9412: 131 programmable relay outputs 9000 Series Control/Communicators Integrated Security Systems for Intrusion, Fire and Access Control (Models: D7212, D74129 D9112, and D9412) System Response • D7212/D7412: 75 points, 8 on -board, up to 67 off -board D9112/D9412: 246 points, 8 on -board, up to 238 off -board • 31 custom point indexes, including fire supervisory • Selectable point response time • Fire alarm verification • Fire inspector's local test • Watch mode • Scheduled events (Skeds) arm, disarm, bypass and unbypass points, control relays, control authority levels, control door access and more User Interface • Supervises up to 8 command centers (up to 32 non -supervised command centers can be used) • Custom command center text • D7212/D7412: 4 custom functions D911209412:16 custom functions • Full function command menu including custom functions • D7212/D7412: 99 Users D9112/D9412: 249 Users • Each user has authority by area and 16-character name • 14 custom authority levels control user's authority to change, add, delete passcodes or access control tokens/cards, disarm, bypass points, initiate system tests, and more • Adjustable brightness/loudness for command center display/ sounder • D7212/D7412: 1 parallel printer D9112/D9412: 3 parallel printers Access Control (D7412/D9412) • D7412: 2 access control doors and 396 tokens/cards D9412: 8 access control doors and 996 tokens/cards • Custom door strike, point shunt and auto disarming response by area • Logging options for: Access Granted, No Entry, Request to Exit and Request to Enter • 14-panel wide access levels with both manual and scheduled control L923 P/N 39173E (6/98) 9000 Series Specification Sheet © 1998 Radionics, Inc. 1 System Description Security and Fire Detection 9000 Series Control/Communicators provide an integrated solution to Access Control, Security, and Fire Alarm System applications. Control / Communicators are capable of monitoring alarm points for intruder or fire alarms while operating user command centers, (access readers, door locks - D7412/ D9412), and other outputs. Includes a built-in digital communicator which reports events to selected destinations via 4 programmable route groups. Programming and accessory modules offer flexibility and beneficial features rarely found in other security control systems. Area Configurations 9000 Series' area programming offers you a wide selection of different system configurations. Each area is assigned an account number to define annunciation, control, and reporting functions. Multiple areas can be linked to a shared area which is automatically controlled (hallway or lobby). Area arming can be conditional on other areas (master/associate). User Interface 9000 Series command centers provide on -premises point and system status annunciation. A fully selectable user interface can customize command center displays and simplify operation by creating menu items and functions, appropriate only to that command center. Function Lists can help a user become familiar with the operation of the control panel. Custom functions allow users to perform complex functions with a few keystrokes. Each may be programmed and identified by 16 characters of custom text and contain up to 32 keystrokes. D1255 Command Center, D1256 Fire Alarm Command Center and D1257 Fire Alarm Annunciator use a 16- character English language display to show system status, area status (custom text), and point status (custom text). D720 8-point LED area command center provides command functions and annunciation for up to 8 points in a single area. Any combination of these command centers may be used within the same area. Easy to remember commands like Command 1, Command 2, and Command 8 make an easy transition for seasoned Radionics users. UserPasscodes 9000 Series can accommodate: • D7212/D7412: 99 user passcodes D9112/D9412: 249 user passcodes. (Each passcode individually programs with 3 to 6 digits in length and no fixed digits). Each user is assigned one of 14 customized authority levels in each area. You may restrict passcodes to operate only during certain times. Each user may have a 16-character customized name that may be viewed, printed, reported to a central station in radionics' Modem 111a2TM Communications format or retrieved with Remote Account Manager (RAM). 9000 Series provide eight "on -board" detection points, and up to 238 additional off -board points (depending on Model and expansion interfaces). Points may be individually programmed and used to monitor all types of burglar alarm, fire alarm, and supervision devices. Communications 9000 Series have four route groups, sorts reports by priority and are capable of transmitting reports to up to four locations. Each group has a programmable primary and backup destination. Radionics' Modem IIIa2TM Communications Format, available with Radionics' D6500 Receiver, adds these reporting capabilities. To name just a few: • Individual point numbers and text • Opening/Closing reports by area number • Remote programming attempts • Diagnostic reports • Access control events with user name Event Log Storage, Viewing and Printing 9000 Series' event log automatically stores up to 1000 events. All local and transmitted events are stored (some access events are selectable). Event log includes time, date and event, with area, point and user number. Users may view event log from Alpha Command Centers. Events may be retrieved remotely using RAM. Events print as they are stored in event log. D9131A Parallel Printer Interfaces can be installed to record events locally on one, two, or three printers (depending on model). Each can print opening and closing, access, alarm, Skeds, or any combination of events. Each can print information from any combination of areas. Each can supervise various printer status conditions. Event log and local printer are ideally suited for customers who like to have a record of openings and closings without having extra communications costs. Logger and Remote Account Manager, can suppress reports and then retrieve events periodically using one phone call, rather than receiving several calls each day. When the panel's event log reaches its programmed threshold of stored events, it can send a report to D6500 Receiver to remind central station to retrieve events from the panel's event log with Remote Account Manager. Scheduled Events (Skeds) 9000 Series' internal clock and calendar help the panel operate individually scheduled events (Skeds). Skeds performs a specific function (such as arm/disarm, relay control, point bypassing, etc.). Each Sked is programmed for a time -and -day -of -week schedule or a date -of -year schedule. Users may change Sked Time if programmed for local time editing. Holiday schedules can enable or disable individual Skeds during holiday periods. • 64 scheduled events with up to 26 different functions • Day -of -week or date -of -year schedules • Four holiday schedules of 366 days each (leap year) L923 P/N 39173B (6/98) 9000 Series Specification Sheet © 1998 Radionics, Inc. Fire Test Specifications 9000 Series Fire Test Mode suppress reports to central station so you can test initiating and indicating devices without transmitting alarms. Initiating Fire Test Mode, sends "Fire Walk Start" to central station indicating start of test. Test events become "local only". Command center shows how many points are to be tested. Each time a device initiates an alarm, programmed point text displays at command center and fire bell rings for 2 seconds. Automatic sensor reset feature allows continued testing of devices without time consuming trips to manually reset sensors. At the end of test, command center displays number of untested points. You can also view point text for each untested point. Ending Fire Test Mode, sends "Fire Walk End" to central station indicating end of test. Combining Access Control with Security and Fire Detection (D7412/D9412) 9000 Series' combined systems can help prevent false alarms making it easy to use one system that controls access, security, and fire functions. Access control features of D7412/D9412 can deny access during armed periods, grant access only to certain authorized users depending whether an area is master armed, perimeter armed or disarmed. Alarm system can automatically disarm when designated authorized users are granted access. • D7412: Two (2) access doors / 75 detection points • D9412: Eight (8) access doors / 246 detection points D9210B Access Control Interface Module Access is granted from Wiegand format readers or Re- quest to Enter/Exit devices when connected to D9210B. Also provided are connections for door point, strike, buzzer and enclosure tamper. (One D9210B required per door). • Each access door can be configured independently • Door point controls access door and is part of alarm system (door does not need double contacts) • Door contact can reset strike time when opened • Door contact can terminate entry buzzer (if used) • Door contact is shunted when valid access is granted • Optional buzzer can trigger prior to end of door shunt period, warning user a "door left open" condi- tion is about to occur. • Door point can be configured to generate alarm or trouble (or have no response) when door is left open beyond shunt period • In addition to granting access, cards control whether system will disarm along with granting access • Door strike can release automatically during dis armed periods, then automatically re -lock when area is armed • Door can generate an alarm, trouble, (or have no response) depending on area's armed condition when door is opened outside authorized access period • REQUEST TO ENTER and REQUEST TO EXIT can be programmed to shunt door without activating strike • An option determines whether access granted, no entry, request to enter, or request to exit messages are sent to event log General Contractor shall furnish and install, where indicated on plans, a Radionics 9000 Series Control/Communicator. Panel shall be listed by Underwriters Laboratories for NFPA 72 Applications. 9000 Series shall support initiating and indicating modules and Radionics Command Centers. Power supply shall provide 1.4-amp @12 VDC for all processing functions and auxiliary requirements. Software 9000 Series' programming of all system functions shall be accomplished on site using Radionics D5200 Programmer or remotely using Remote Account Manager software package. A programmable system passcode shall be used to prevent unauthorized remote programming. Panel shall accommodate up to four separate telephone numbers for primary, alternate and backup receivers, automatic test reports, selective relay activation, and custom text on associated command centers and annunciators. When resetting alarms, arming or disarming a combination fire/burglary and/or access control system, user shall be identified by name and number. D7212/D7412: Up to 99 users D9112/D9412: Up to 249 users Panel's internal clock shall support Skeds (scheduled events) feature. User shall have option to alter Sked activation times using a programmable passcode. Up to 64 programmable scheduled event functions shall be available for controlling relays, enabling passcodes, windows, and supporting service alert feature. Other programmable functions shall include fire alarm reset commands, and day/date/time adjustments. Event Logger/Clock 9000 Series' event log shall store up to 1000 events. All system events shall include time, date and event with area, point and user number. Access events (optional) stored shall include: Access granted, no entry, Request To Enter, and Request To Exit. Logger records certain functions entered at command centers. Stored events in Logger shall be retrievable with a Remote Account Manager software package. Remote Diagnostics and Controls 9000 Series shall be able to be remote controlled through use of Remote Account Manager software. Features shall include: reset of audible signals, activation/ deactivation of D8129 relays, interrogation of battery, point and armed status, enabling or disabling reporting functions, and shunting of reporting points during servicing. © 1998 Radionics, Inc. 9000 Series Specification Sheet L923 39173B (6/98) RJ Specifications (cont'd) Command Centers Accessories 9000 Series command centers shall be Radionics D1255 Command Center, D1256 Fire Alarm Command Center and D1257 Fire Alarm Annunciator. Each shall be equipped with a 16-character alphanumeric display, distinct fire and burglary tones, and backlighted multi - key touchpad. D1255, D1256, and D1257 shall have the abilityto display for each detection point: alarm, trouble, supervisory, or faulted, and custom text. In addition, expanded, addressable point displays shall include missing and extra point information. System -wide displays shall include: local system test, sensor reset, fire test mode, and user programming prompts. Fire Test 9000 Series' Fire Test Mode shall support single -person operation. All reports to central station shall be suppressed while fire test is being conducted. Fire Test Mode shall be activated by entering a user passcode at command center. All testing data shall be visible on command center and annunciator displays during testing. Hardware 9000 Series shall provide up to 246 individually identified addresses, (75 with D7212/D7412). Each shall accommodate normally open and/or normally closed devices with end -of -line resistor supervision. Each point shall be programmable for fire, fire supervisory or burglary applications. Point output shall be silent or audible. Audible output shall be steady, pulsed, CA standard, or temporal code 3. External Hardware 9000 Series shall allow use of up to three on -site parallel printers (one with D7212/D7412), using Radionics D9131 A Printer Interface Modules. Events shall print time, date, and event description with area, account, point, and user number, including text for points and users. Installation, Warranty, and Training 9000 Series System Installation, wiring of initiating devices and signaling circuits, shall be the responsibility of installing company. Warranty on all components shall be one year, subject to manufacturer's limitations. Training on complete system operation shall be furnished by installing company upon completion of installation. Listings and Approvals Fire UL: Central Station, Local, Auxiliary, Remote Station, and Household Fire Warning. CFSM, FM and NYC-MEA approved. Burglary UL: Central Station, Local, Police Connect, Bank Safe and Vault, Mercantile Safe and Vault, and Grade A Household DOD: Approved for installations in Sensitive Compart- mented Information Facilities (SCIF). Access UL: Access Control Systems. Command Centers, Keypads and Accessories: D1255 Command Center D1256 Fire Alarm Command Center D1257 Fire Alarm Annunciator D720 8 Point LED Area Command Center D268 Independent Point Control Module D269 Independent Point Control Keypad D279 Independent Point Control D54B Command Center Flush Mount Kit, Brass D54C Command Center Flush Mount Kit, Stainless D55 Command Center Desk Stand D56 Command Center Surface Mnt. Conduit Box Zone Expansion and Interface Modules: D8125 POPEX Module D9127U/T POPIT Module, U=No Tamper / T= Tamper D8128C OctoPOPIT Module D940 Super Loop Module D8129 OctoRelay Module D127 Reversing Relay D136 Plug-in Relay D8121A Derived Channel S.T.U. Non UL D8122 Derived Channel S.T.U. UL Listed D9131 A Parallel Printer Interface Module D9210B Access Control Interface Module Detection Devices with Built-in POPIT: ZX835 PIR/Microwave Detector, 35 ft. x 35 ft. ZX970 PIR/Microwave Detector, 60 ft. x 60 ft. ZX935Z PIR Detector, 35 ft. x 35 ft. ZX776Z PIR Detector, 50 ft. x 50 ft. ZX794 PIR Detector, 90 ft. x 90 ft. ZX938Z PIR Detector, Ceiling Mount, 360' x 60 ft. D278S Smoke Detector Base 12 VDC D298M Smoke Detector Base, Master, 24 VDC D298S Smoke Detector Base, 24 VDC Fire Alarm Modules and Accessories: D125B Dual Class B Powered Loop Interface Module D129 Dual Class A Initiation Circuit Module D130 Auxiliary Relay Module, 12/24 VDC D184 Auxiliary Local Energy Interface Kit D185 Reverse Polarity Interface Module D192C N.A.C. Module, Class B, 12/24 VDC, 1.8-amp D192D N.A.C. Module, Class A/B, 12/24 VDC, 3-amp D928 Dual Phone Line Switcher D8130 Release Module Power Supplies,Transformers, Batteries & Accessories: D9142F Auxiliary Power Supply, 24 VDC, 4-amp D8132 Battery Charger Module, 12 VDC D1640 16.5 VAC 40 VA Transformer D113 Battery Lead Supervision Module D122/L Dual Battery Harness/Long Leads D126 Battery, 12 V, 7 Ah D1218 Battery, 12 V, 17.2 Ah Enclosures, Brackets, and Phone Cords: D8103 Universal Enclosure D8109 Fire Enclosure D8108A Attack Resistant Enclosure D8004 Transformer Enclosure D137 Module Mounting Bracket D101 Lock and Key for D8103 D161/162 Dual Mod. Telephone Phone Cord, 7 ft./2 ft. Programming Products: D5200 Programmer D5400 Remote Account Manager, RAM L923 P/N 39173E (6/98) 11998 Radionics, Inc., Salinas, CA, USA. All rights reserved. Radionics' .M The Radionics logo is a registered trademark of 4 Radionics, Inc.,1800 Abbott Street, Salinas, CA. ISO 90020 CERTIFICATE NO. A3946 D1256/011257 Fire Command Center/Fire Annunciator Specifications Features • Compatible with the D9124, D9112, D9412, D7212 and D7412 Attractive low profile fire annunciators • D1256 provides system control with easy to use function keys • D1257 can be remotely installed in public access areas • Built-in multi -tone sounder • Easy to read vacuum fluorescent display • Displays complete system status in English format • Programmable custom text for each point Local systemtest display • Molded red ABS plastic construction Description Radionics' b1256. Fire Command Center and D1257 Fire Alarm Annunciator are four -wire serial devices used with the Radionics' D9124 Addressable 24 VDC Fire Alarm Control/ Communicator and the D9112, D9412, D7212 and D7412 Control/Communicators. One D1256 is included with the D9124 panel, which can be accessed through the slide door on the front of the enclosure. Both annunciators provide English text displays of system events with highly visible blue vacuum fluorescent displays. A built-in sounder alerts building personnel to system alarms and troubles andguides responding agencies to the annunciator location. Both" units are molded' in durable red plastic and have low profile enclosures: The wording "Fire Alarm Annunciator" is clearly printed on the faceplate of the D1257. This allows inspectors: service technicians and responding fire agencies to identify the annunciator. The D1256 Fire, Command Center is a full -function system controller and annunciator. Four special one -touch function keys provide user-friendly control over the system. The function keys allow the user to silence the audible alarm output, silence the trouble sounder, reset the annunciator display and reset system detectors. Four additional navigational keys allow access to other programmed system functions. The D1257 Fire. Alarm Annunciator provides remote annunciation capabilities without system control. Similar in appearance to a D1256 Fire Command Center, yet the D1257 Fire Alarm Annunciator lacks function keys. This makes system control functions inaccessible to unauthorized persons: Thus, the D1257 can be placed in locations where the public may have access to it. Two navigational keys allow the user to step forward or backward through a list of system events. Radionics Fire Command Center and Fire Annunciator . Application The D1256 can be mounted in secure areas for use as both a system controller and annunciator. a The D1257 Remote Fire Annunciator is typically installed in building entrances and areas with unrestricted access. Near exterior -.doors in hotel or business lobbies are ideal locations. l This allows a responding agency, or persons evacuating the l building to quickly identify the type and location of the j emergency.from,outside the building without being in danger. Both devices have a built-in sounder that allows them to be installed in locations not in general .view. Audible tones alert s personnel to fire system events and assist fire fighters in locating the annunciator. Installation The D1256 and D1257 system annunciators connect to the fire control/communicator through standard four -wire cable. l Shielded cable may sometimes be required where excessive EMI is a problem. The field wiring connects to a four -wire harness supplied with the unit. This harness plugs into a four -pin connector on the circuit board through the back of the D1256 or D1257. Each unit has three mounting holes in the base that allow secure, correct positioning during installation. Do not install the D1256 or D1257 in direct sunlight. This damages the module components and makes the display less visible. Install, test and maintain these devices according to their Installation Guides, NFPA 72, Local Codes and the Authority Having Jurisdiction. failure to follow these procedures may result in failure of the devices to operate properly. Radionics is not responsible for devices that are improperly installed, tested and maintained: 1 Operational Data The D1256 and D1257 operate through the Serial Device Interface buss of the control/communicators. The D1256 and D1257 receive serial data and power through a four -wire cable. Both devices continually show the status of the fire alarm system. Changes in the normal panel condition such as alarm or trouble events are displayed in alphanumeric English text and the appropriate sounder response tone emitted. Resetting the display and sounder can only be accomplished at the D1256 Fire Command Center by authorized persons. Specifications D1256/D1257 Specifications Operating Voltage Nominal 12 VDC (supplied by control/communicator) Operating Current 104 mA min.; 206 mA max. Wiring Four conductors supply: Serial data, +12 VDC and panel common Display 16-character vacuum fluorescent Operating Temperature +32°F to 122°F (0°C to +50°C) Non -condensing Relative Humidity 5 % to 85 % at 86"F (30°C) Base Dimensions (L x W x D) 8.3 in. x 4.5 in. 0.8 in. (21 cm x 11.4 cm x 2 cm) Wire Information Four -Conductor from Panel D1256 or D1257 Wiring Harness 12 VDC 12 VDC (Red) Data -Out Data -In (Yellow) Data -In Data -Out (Green) Common Common (Black) © 2001 Radionics, a division of Detection Systems, Inc. ® The Radionics logo is a registered trademark of Radionics, PO Box 80012, Salinas, CA 93912-0012 USA Customer Service: (800) 538-5807 Listings and Approvals • UL Listed • CSFM Listed • FM Approved Ordering Information Model Number Description D1256 Fire Command Center D1257 Remote Fire Alarm Annunciator D54B Brass Faceplate D54C Stainless Steel Faceplate D55 Desk Stand D56 Conduit Backbox Specifications The contractor shall furnish and install, where indicated on the plans, Radionics D1256 Fire Command Center and D1257 - Remote Fire Alarm Annunciator. Each device shall have a 16 l character vacuum fluorescent display and show all fire system events. Alarms shall be prioritized ahead of other system events and displayed in sequence. The D1257 shall have no on board system control function keys. A built-in sounder shall indicate events with distinct tones for fire alarm and system trouble. The D1256 and D1257 shall l connect to the fire control/communicator through a four -wire cable. The D1256 and 1257 shall be constructed of high impact red plastic. The D1257 shall have the text "Fire Alarm Annunciator" clearly printed in bold letters to the right of the event display. The D9124, with the D9112LTB, D9112131 and D7212131, have a 500 event non-volatile event memory log. The D9124 with the D9112LTB-EX or D9412GLTB, 9000/7000 Series panels have a 1000 event non-volatile memory log. All system events are displayed on system annunciators, printed locally or retrieved from off premises via the Remote Account Manager (RAM) software package. ISO W02 U� CERTIFICATE NO. A5137 75-06926-000-B 01/01 Specifications D1256/D1257 ! _ L643 Page 2 of 2 i D928 Dual Phone Line Switcher Specifications Features • Dual Phone Line Switcher • Automatic switching to alternate phone line • D9124, D9412, D9112, D7412, D7212 CPU (Central Processing Unit) supervision • CPU failure annunciation • AC Status LED • Primary and alternate phone trouble LEDs • Communication fail LED Description Radionics' D9124, D9412, D9112, D7412, D7212 Control/Communicator panels use the D928 Dual Phone Line Switcher to transmit over an alternate phone line when the primary phone line 'is faulted: The D928 monitors the alternate line and the panel monitors the primary line. If a signal is generated and the panel senses that the primary phone line is bad, then it will attempt to use the alternate phone line to send the message. If trouble is detected, the panel keeps the faulty phone line in memory. If the primary line is found to be electrically faulty, the D928 switches to the alternate phone line and reports the fault. The D928 uses the primary or alternate phone line to dial a primary, backup or duplicate phone number. When using Modem llla,TM, the panel sends a phone line failure message to the D6500 or D6600 Receiver, indicating which phone line is in trouble. The panel sends two distinct messages for trouble on the primary or alternate phone line. The D928 also has a circuit that monitors the panel's CPU for proper operation. If the CPU fails, a buzzer on the D928 sounds as does.a sounder in the panel. This sounder cannot be reset while the CPU is failed. Four LEDs mounted on the front edge of the D928 serve as status LEDs by displaying primary and alternate phone line failure, failure to communicate and AC power status. D928 Dual Phone Line Switcher Application All reporting fire alarm systems are required to have a primary and alternate means of transmitting reports to a receiver. Typical D928 applications are schools; factories and care facilities where the ability of the system to relay information off -premises. is especially critical for safeguarding life and property. Installation The D928'Dual Phone Line Switcher mounts inside the Fire Alarm Control Panel (FACP.) enclosure. Mount the module to the inside of the enclosure as instructed in the appropriate Operation and Installation Manual. The D928 connects to the control/communicator through the interconnect wire provided. The ribbon cable attaches to the panel's accessory connector. The D928 is programmed at the control panel using the appropriate Program Entry Guide. Install, test and maintain this device according to its Installation Guide, NFPA 72, Local Codes and the Authority Having Jurisdiction. Failure to follow these. procedures may result in failure of the device to operate properly. Radionics is not; responsible for devices that are improperly installed,: tested or maintained. Specifications Idle Current 18 mA @13.8 VDC Maximum Current 100 mA @ 13.8 VDC Operating Voltage 10.2 to 13.9 VDC supplied by the control/communicator Status Indicators LEDs indicate primary phone line fail, alternate phone line fail, failure to communicate and AC power status. Buzzer annunciates CPU failure. Wiring Connections Standard Modular Connections Dimensions (H x W x D) 5 in. x 3 in. x 3.8 in. (13 cm. x 8 cm. x 2 cm.) Listings and Approvals • Underwriters Laboratories • FM • NYC-MEA CSFM Ordering Information Model Desedption �....h n. D161/D162 Dual Modular Phone Cords D928 Dual Phone Line Switcher IS0 9002 UL CERTIFICATE NO. A5137 © 2001 Radionics, a division of Detection Systems, Inc. 75-07163-000-C 8/01 PO Box 80012, Salinas, CA 93912-0012, USA Specifications D928 (800) 538-5807 L1095 Page 2 of 2 D8132 Battery, Charger Module Specifications Features • Provides additional standby Amp hours for control/communicators • 1200mA battery recharging circuit • Suitable for 12 VDC; 7 and 18 Amp -hour batteries • Suitable as a stand alone 12 VDC, 1 Amp power supply Description The D8132 Battery Charger Module is an accessory device for Radionics D6112, D7112, D8112,'D8124, and 9000 Series control/communicator panels. The D8132 uses a 16.5 VAC, 40 VA plug-in transformer to supply 1200mA of battery charging current. An on- board, green LED remains lit to indicate the presence_ of AC voltage. The D8132 can be used to increase the standby battery time of a panel when installed with external batteries in an adjacent approved enclosure. The D8132 is not to be used as the sole means of standby power for a panel. One or two 12 VDC, 7 Amp -hour batteries must still be provided for the panel. The D8132 can also be used as a stand-alone power supply, in non-UL applications. You can connect one or two 12 VDC, 7 Amp -hour batteries or one or two 12 VDC, 18 Amp -hour batteries to the D8132 in either application. In addition to providing increased standby time and auxiliary power, batteries connected to the D8132 also filter the AC power supply. The amount of ripple that appears on the panel outputs is dependent on the charge state of the batteries. Radionics does not recommend using the D8132 to power'devices that are sensitive to excessive ripple. Application The D8132 Battery Charger Module is suitable for systems requiring extended battery standby time. The D8132 is UL listed for use in Central Station. Household and Local Fire and Burglary Alarm applications, Police Connected, Remote Station, and Electrically Actuated Transmitter applications. The D8132 is not UL.listed for use with the D6112. Provided with the D8132 are two cables, and two sets of lockwashers, nuts, screws, and terminal lugs. The cables connect the D8132 to the D1640 transformer, one or two batteries, and the control/communicator. Additional hardwareis provided for connecting the hardware is not required when connecting 12 VDC, 7 Amp -hour batteries. Installation The D8132 Battery Charger Module and additional batteries are typically mounted inside a separate approved enclosure such as the. Radionics D8103, D8108A,.or D8109. The enclosure is installed adjacent to the control/communicator enclosure. The plug-in AC transformer is installed on the same AC branch circuit as the control/communicator transformer. No other devices may be connected to the transformer. A 4-wire harness is used to connect one or two batteries to the.D8132. An additional 4-wire harness connects to the AC transformer (2 wires) and the battery terminals of the control/communicator. The D8132 installs in the enclosure using three plated screws` supplied with the unit. Radionics enclosures provide -module mounting locations with knockouts. Use a. Radionics D137 Mounting Bracket when installing the D8132 in a non-Radionics enclosure. The D8132 should be mounted towards the top of the enclosure away from the batteries to avoid overheating. The Radionics D8103, D8108A, and D8109 enclosures provide a rectangular knockout on the door that allows the green AC power LED on the. D8132 to be easily viewed. battery cable to 12 VDC 18 Amp -hour, batteries. This R 16n,i s' Operational Data When using the D8132 to increase your control/communicator panel standby battery Amp hours, refer to the appropriate calculation chart contained in the D8132 Operation and Installation Manual (74-04777-000). These charts detail the Amp -hour requirements, control/communicator Auxiliary current load, and the D8132 battery recharge time. The D8132 can also be used as a stand-alone, 12 VDC 1 Amp power supply. For stand-alone applications the D8132 does not provide battery supervision or load shed capability and is not recommended for critical loads. The D8132 is not LIL listed for stand-alone applications. A form of battery supervision can be provided to a D8132 in stand-alone configurations when connected to the same AC branch circuit as the panel. AC power failures and restorals, which would also affect the D8132 module, can be reported by the panel to a remote receiver. This supervision relies on the assumption that AC power to both devices has been affected. The Amp -hour rating of batteries on the D8132 should be greater than batteries connected to the panel. This ensures that devices connected to the D8132 are powered at least as long as those on the control/communicator. The stand-alone D8132 and the panel must share a common ground. Specifications Operating Voltage 16-18 VAC supplied by plug-in transformer Operating Current 1200mA of rectified AC Float Voltage 13.9 VDC maximum current Length 5.0" Width 3.0" Depth .75" The contractor shall furnish and install Radionics model D8132 Battery Charger Module where indicated on the plans. The D8132 shall provide increased standby Amp -hours for the specified Radionics control/communicator panel. The module shall be equipped with a 16.5 VAC, 40 VA plug-in transformer, two sets of connecting cables and all hardware required for proper installation. The D8132 shall have an on- board, green LED for indicating the presence of AC power. The D8132 shall be capable of supplying recharging current for one or two 12 VDC, 7 Amp -hour or 18 Amp - hour batteries. The module shall be mounted in the recommended Radionics enclosure or other approved enclosure. Installation shall be subject to the requirements of the authority having jurisdiction. Listings and Approvals • A Listed • CSFM and NYC -BSA approved Ordering Information t A46 eil Descrt!tidn u D126 12 VDC 7.0 Amp -hour Battery D137 Mounting Bracket D1218 12 VDC 18 Amp -hour Battery D8132 Battery Charger Module ISO 9002 WIL CERTIFICATE NO. A5137 © 2000 Radionics, a division of Detection Systems, Inc. 75-06430-000-B 02/00 ® The Radionics logo is a registered trademark of Radionics, Specifications D8132 PO Box 80012, Salinas, CA 93912-0012, USA L515 Page 2 of 2 4, .•.. Manual Alarm Box Specification Features • Rugged die cast housing • 14 Ga. Plated steel back plate • Single gang mounting • Corrosion resistant construction • 10 Amp 120 VAC contacts • Key locked reset • Screw terminal connections • Optional break glass rod • Latching pull down lever Description The Radionics D461 Manual Fire alarm Box is a single action, UL listed fire alarm initiating device. It has one set of normally open contacts rated for 10 Amps at 120 VAC. The D461 has an easily identified pull down lever and contains an integral break glass rod carrier. The unit is a high quality manual fire alarm box constructed entirely of non -toxic materials with a low profile and rounded edges to fit most design applications. All components are prepainted or have plated surfaces to inhibit corrosion. Non -corroding screw terminals are provided for wire connections to the D461. The D461 is manufactured in conformance with the standards set forth in the Americans with Disabilities Act. Application The D461 Manual Fire Alarm Box is an accessory device for Radionics control/communicators and is typically used in fire alarm applications. Manual fire alarm boxes are generally installed near building fire exits such as lobbies or stairways. Persons evacuating the building during an emergency are able to initiate an alarm by pulling down a lever. This alerts others who may still be inside. The snap lock feature of the D461 prevents the unit from being reset without a key so the origin of the alarm can be more easily determined. The 10 Amp, 120 VAC contact rating allows the D461 to handle larger current loads. This makes the unit an ideal choice for both new installations and retrofits. Listings and Approvals • UL listed • NYC-MEA pending • CSFM listing no. 7150-0801:113 Accessories • D463 Double -Action Cover: Hinged red lid requires lift - and -pull action on part of the user. • D465 Replacement Rod: Replaces glass rod that breaks when the lever is pulled. • D466 Back Box: The D461 is mounted in a red metal backbox, the D466. Installation The Radionics D461 Manual Fire Alarm Box is a UL listed fire alarm initiating device. The D461 is installed alone or with other approved mechanical devices on Radionics control/communicators. Manual fire alarm boxes must be installed according to codes set by the authority having jurisdiction. The D461 mounts to a standard flush or surface mounted single gang switch box or plaster ring. Slotted screw holes allow for correct positioning during installation. Two corrosion resistant screw terminals are provided for wire connections. All wiring and installation is subject to the authority having jurisdiction. Ordering Information Model Description D461 Manual Fire Alarm Box D463 Double -Action Cover D465 Glass Replacement Rod D466 Backbox, Red 75-06561-000-B 6/94 - © 1994 Radionics Electrical Specifications Contact current rating 10 Amps at 120 VAC Operational Data The D461 has a white pull down lever in its center. Pulling down the lever latches it into place. The D461's normally open contact switch is shorted causing an alarm on the fire initiating loop. The pull down lever can not be reset unless the correct key is inserted into the manual fire alarm box lock and the unit is opened. The latching lever can then be restored to its normal position. When the D461 is being reset and has a glass break rod installed, all debris must be removed priorto installing another rod to ensure the unit will close and lock securely. Wiring Information TO FIRE ALARM CONTROUCOMMUNICATOR ZONE OR POINT :X Specifications The contractor shall furnish and install the Radionics D461 Manual Fire Alarm Box where indicated on the plans. All manual fire alarm boxes shall have single pole, single throw normally open contacts rated for 10 Amps at 120 VAC. The D461 shall be UL listed and suitable for use with Radionics fire control/communicators. The D461 shall be constructed of non -toxic, die cast materials with slotted mounting holes for correct positioning during installation. Terminal block connections shall have plated metal screws and fit all applicable wire sizes. For applications requiring double -action activation of the manual station, a D463 Double -Action Cover shall be installed on the D461. The unit shall use a key for resetting and have the option for installing break glass rods as determined by the authority having jurisdiction. No special tools shall be required for replacing the break glass rods. N E.O.L. RESISTOR -0 0 C C ©1994 Radionics, Salinas, CA, U.S.A. All rights reserved. Tm The Radionics logo is a registered trademark of Radionics, Salinas, CA. Radionics, 1800 Abbott Street RadIonicC " _ Salinas, CA, 93901, U.S.A. D126, D1218, D1224, and D1238 12 V Sealed Lead -Acid Batteries Features • 12 V DC sealed lead -acid • Fully rechargeable • Maintenance -free • For use with Radionics Control/communicators • For use as secondary power for Radionics accessory modules • Long service life Description The Radionics 12 Volt Sealed Lead -Acid Batteries are maintenance -free standby and auxiliary power supplies that provide long service life and dependability. The D126 is a 12 Volt, 7.0 Amp -hour battery. The D126 fits in any Radionics enclosure and connects to the two color -coded battery leads supplied with the panel or module. A Radionics D122 Dual Battery Harness may connect two D126 batteries in parallel to double the Amp hour output. The D1218 is a 12 Volt, 17 Amp -hour battery. The D1218 can be used with all Radionics control panels. The D1224 is a 12 Volt, 24 Amp -hour battery. The D1238 is a 12 Volt, 38 Amp -hour battery. The D1218, D1224, and D1238 are larger than the D126 and must be mounted in a suitable enclosure to accommodate their size. One or two batteries are typically installed in a separate approved enclosure adjacent to the control/communicator enclosure. The D1218, D1224, and D1238 have two bolt - fastened terminals and include hardware for attaching battery leads or spade connectors. Application These batteries are for use only with charging circuits calibrated for lead -acid batteries. They are suitable for supplying backup power for all Radionics fire, security, and access control systems during AC power failures. See the control panel Installation Manual for information on calculating the standby battery requirements for the system. Total continuous and intermittent current requirements must not exceed the amp hour capacity of the batteries. Installation The D126 battery installs inside the 7000, 8000, and 9000 series control panel enclosures and connects to the panel through the color -coded D122 Dual Battery harness consisting of two leads. The D1218, D1224, and D1238 are larger batteries and install in separate approved enclosures. Some enclosures do not support two batteries. Refer to the appropriate Control/communicator Operation and Installation Manual. ©1996 Radionics All rights reserved 75-06573-000-B 9/96 Radionics rne Radionics logo is a registered trademark of Radionics, 12 V Battery Specifications _J Q 1800 Abbott Street, Salinas, CA 93901, USA Page 1 of 2 Specifications D126 I D1218 D1224 D1238 Capacity (Ah) 20 hour rate 7.2 17.0 24.0 38.8 (Nominal) Dimensions Model ` Length Width Height with Terminals , Weight (Approx.) D126 6" 2-9/16" 3 3-15/16" 5.45 lb. D1218 j 7-1/8" 3" i 6 -5/8" 14.3 lb. D1224 6-1/2" 4-15/16" 6-15/16" 19.2 Ib. D1238 7 -3/4" 6-1/2" 6-15/16" ( 28.7 lb. Listings and Approvals • Underwriters Laboratories • CSFV, • NYC-:V.EA Ordering Information Model Description D122 Dual Battery Harness D122L j Dual Battery Harness with Long Leads D126 12 V. 7 Ah Battery DI218 12 V, 17 Ah Battery D1224 12 V, 24 Ah Battery D1238 12 V, 38 Ah Battery D8132 Battery Charne_ Module Cc1996 Radio vcs AI': rights reserved 75-06573-000-B 9/96 Radionics- 'The Radio ucs Iogo is a registered nzdezrarlc of Radionics, 12 V Battery Specifications 1800 Abbott Street, Salinas, CA 93901, USA Page 2 of 2 Hadlonics 0=eatu res • Provides point identification of initiating devices • Supervises wiring to devices for circuit integrity • Compatible with D7212, D7412, D8112, D9112, D9412, and D9124 Control/Communicators • Expands the number of points of protection in the system • Compact size • Terminal connections for reliability • Multiplex technology • Low installation costs Description D8125 and D9127 Addressable Expansion Modules Specification Sheet The D8125 and D9127U/T expansion modules are a proven multiplex technology combining zone/point supervision with individual device addressing on one pair of wires. The control/communicators use the D8125 to provide for expansion beyond the standard number of zones up to a total of 240 points of protection. Each D8125 module can fully supervise 120 D9127U/T (Untampered and Tampered) POPITs(Pointof Protection Input Transponders). The D9127 is a compact, addressable device. Future system expansion is very economical as they can be spliced in anywhere along the two wire data expansion loop from the D8125 module. Four screw terminals provide reliable connections for the data expansion loop and supervised sensor loop wiring. Application The D8125 and D9127U/T Modules are used when there is a need to expand the appropriate contro Vcommu nicators beyond their standard number of on -board initiating zones or points. Listings and Approvals • UL listed • NYC-MEA approved • CSFM listing no. for D8125 and D9127: I 7167-0801:104 (household) 7165-0801:102 (non-highrise) Installation The D7212 and D7412 control/communicators use one D8125 expansion module to provide a maximum of 40 additional points of protection. Up to two model D8125 expansion modules can be used with the D8112, D8124, D9112, D9412, and D9124 control/communicators. The D9124 Control/ Communicator basic system comes with an integral D8125 module and can accept one additional module. Each D8125 installs in the control panel enclosure or in an adjacent approved enclosure. You can supervise up to 120 D9127 POPITs with each D8125 module. The D9127U/T POPIT modules are suitable for applications where specifications call for point identification from each initiating device or series of devices. The units are small, and easily installed in standard outlet boxes, above false ceilings, closets, or other accessible locations. CONTROL COMMUNICATOR ZONE EXPANSION LOOP D9127U/T PORT MODULE TO OTHER PORT MODULES DOI25 ZONEX MODULE 33 kLl END-OF'LINE POPIT SENSOR LOO RESISTOR (MONITORS NORMALLY OPEN AND/OR NORMALLY CLOSED DETECTION DEVICES) 75-07506-000-B 3/96 © 1995-1996 Radionics Ordering Information itAodel ey, Description D8125 D7212, D8112, D9112, D9412, D9124 Expansion Module D9127U/T Point of Protection Transponder Electrical Specifications Operating Nominal 12 VDC supplied by Voltage control/communicator Operating 50 mA per D8125 module plus Current 0.5 mA per D9127U/T module Operational Data Each D8125 expansion module monitors the D9127 POPITs over a two -conductor supervised data expansion loop. Off -normal sensor loops (open or shorted), missing, and extra POPITs are quickly identified by device address and the information relayed to the control/communicator. Each D9127 provides one supervised point of protection. Normally open and/or normally closed contacts may be connected on the same sensor loop. A 33k Q EOL resistor is provided to be installed at the furthest point on the loop for proper supervision. Wiring Information Specifications The contractor shall furnish and install the D9127 PORT expansion modules as indicated on the plans. Each POPIT shall provide a supervised sensor loopfor initiating devices and identify the device status in off -normal conditions. Each PORT shall be assigned a device address as indicated on the plans and annunciate at the specified locations. The POPITs shall connect to a 2-wire data expansion loopfrom a D8125 installed in the control/ communicator enclosure. The D8125 module shall be used for D9124, D9112, D9412, or D8112 control/communicators and provides supervision for up to 63 or 120 D9127 POPITs on each of up to two modules. The D8125 module shall be used for D7212 control/ communicators and provide supervision for up to 40 D9127 POPITs. Specified Radionics control/communicators shall be capable of providing device point identification to a remote Radionics D6500 receiver using the Modem II reporting format. All wiring shall be in accordance with the manufacturer's instructions and follow all applicable codes. Dimensions D8125/D8125X: 5" L x 3" W x 3/4" D = D9127 SENSOR LOOP D9127U/T: 3 3/16" L x 1 1 /2" W x 7/8" D © = 33K a END-OF-LNE RESISTOR (D = D9127 SVPITCH BLOCK PO ® aO ® O MODUDU LE MI � O m®n � � B t-I � X TERMINAL t•I D9127U/T D9127UIT D9127U/T D9127U/T CONNECTORS t•I-T. :"LI!06 1!!(Db TO&O GNoour ux OO OO OO (-) a - POSITIVE (+) ZONE EXPANSION LOOP • AUX POWER POPEX GND MODULE#2 [TEO Q ® OO ® O O IV 1-1 N an t•) O l•) D9127U D9127U D9127U D9127U °":"ioro :"n(D@ :"loan aHo SERIAL DATA IN our SERIAL DATA OUT 8-Auz O OO O OO O a` NEGATIVE(-) POSITIVE (+) e6ee9eeeeee6 ZONE EXPANSION LOOP •a MASTER EXPANSION ZONES ZONES -� Hl The Radionics logo is a registered trademark of Radionics, Salinas, CA, U.S.A. ©1996 Radionics, Salinas, CA, U.S.A. All rights reserved. RQdlonic$ Radionics, 1800 Abbott Street, Salinas, CA, 93901 U.S.A. L. The DS280 Series are low profile, Photoelectric System type smoke detectors. The patented chamber design provides superior immunity to false alarms caused by dust. Chamber CheckO self diagnostics allow the sensitivity to be verified by simply looking at the detector LED. Several different models are available, offering a wide variety of features and outputs. FEATURING ..... • Direct Wire Design with Removable Terminal Strip • Diagnostic/Sensitivity Test Features • Chamber CheckO Self Diagnostics • Field Replaceable Smoke Chamber • Easy Disassembly for Cleaning - Sensitivity Voltage Output • 12 or 24 VDC Operation • 135OF1570C Heat Sensor Option • UL Listed, ULC Listed • CE Detection Systems, Inc. OPTIONAL ACCESSORIES ® The International Leaders of Access, Fire, Intrusion and Sensor Products. SPECIFICATIONS POWER REQUIREMENTS 2-wire: 8.5 to 33VDC 4-wire: 10 to 30VDC RELAY CONTACTS Form "A": Alarm and Trouble Relay Contacts, 0.5A, 200V (Normally Open). Form "C": Auxiliary Contact, 1A, 220VDC, 250VAC (Normally Open/Closed/Normally Closed). RADIO FREQUENCY No alarm or setup on critical frequencies in the range of 26 to 950 Megahertz at 50v/m. INTERFERENCE (RFI) IMMUNITY STORAGE & OPERATING +32°F to+120OF (0°C to 40°C) 0 to 95% relative humidity (non -condensing). TEMPERATURE TEST FEATURES LED automatically flashes to indicate a calibration trouble and latches on alarm. Sensitivity can be verified using visual check, magnet test or digital volt meter. CHAMBER CHECK® The Chamber Check® automatic sensitivity feature provides an indication if the detector is outside the factory calibrated specifications. This feature reduces service costs because the installer can easily determine which detectors require attention. This feature also reduces false alarms by alerting the end -user that the detector is dirty long before the possibility of producing a false alarm. A visual indication is provided in all IDS smoke detectors. The DS284THR and DS284THSR include a trouble relay, allowing this indication to send a report to the central station. PATENTED CHAMBER The detection chamber includes computer designed chamber walls and lenses to optimize internal DESIGN light scattering and dust hiding capabilities. This provides for industry leading dust immunity without sacrificing detection. The detection chamber can be easily removed should it require cleaning, and is field replaceable. Replacement chambers are available in packs of ten (10). SOUNDER 85db sounder activates on detector alarm or reverse polarity. Available on detectors with "S" in model number (see features chart). TROUBLE RELAY Indicates Chamber Check® trouble condition or loss of power (DS284THR and DS284THSR only). ENCLOSURE DESIGN High impact, fire retardant ABS plastic enclosure and separate twist -lock mounting plate. The DS282 and DS284 detectors measure 2 in. (5 cm) High by 5 in. (12.7 cm) in Diameter. MOUNTING Separate mounting plate mounts directly to 4-inch octagonal electrical box, single gang box and wiremold surface box #5738. A removable terminal strip allows for quick installation. HEAT SENSOR 135°F (57°C). TEMPERATURE OPTIONAL ACCESSORIES RC3-10' Replacement Chamber, EOL200 End -of -Line Supervision Module, TC2000 Test Cord, DT1 RemovaUrest Tool (suitable for testing only, not for installation/removal). ' Shipped in packages of 10. TP280 Trim Plate for retrofit and remodeling purposes. 6 in. (16.2 cm) diameter. LISTINGS U.L. Listing S3019, CSFM #7272-1062:108. U.S. PATENTS #5,400,014, #5,543,777, #5,552,765. ORDERING INFORMATION Model , ' 2 W►re/=, 135Heat 85db% Trouble EOL Auxlhary ++£ Current Drawl '', 7 xy Number...- 4 wlre' Sensor ° Sounder Rela y Rela y Relay Standby , Trouble Alarm ? DS282 2-Wife 80uA @m12V, IOWA— Determined by panel DS282TH 2-wife • 80uA @ 12V, oouAmax Determined 1OOUA max by panel DS282THS 2-wire e • 80uA @ 12V, oouAmax Determined 1OOuA max by panel DS282THC 2-wife • • BOuA @ 12V, 00uAmax Determined 100,A max by panel DS284 4-wire 80uA @ 12V, OOuA max 18mA max (+/. 100uA max 5mA) @ 30V DS284TH 4-wire • B0uA @ 12V' mouA max IBmA max (+/. 100uA max SmA) @ 30V DS284THS 4-wire • • 80uA@12V, 100uA max 78mA max(+/- 100uA max 10mA) @ 30V DS284THR 4-wire • e 18 mA max @ 30 V 1OOuA max 18mA max (+/. SmA) @ WV DS284THSR 4-wire • • • max @ 30 V 96mA max.00Amax DS284THCS 4-wire • • • uA @ 12V, 00uA ma 90MA max (+ /-OOuA r18MA me 10mA) @ 30V DS284THC 4-wire • • A @ 12V oouA max 33mA max ' OOA ma 10mA) @ 30V DS284THE 4-wire • • 15mA 15mA max. (+/- 2mA) @ 12V 36mA max (+/- SmA) @ 30V DS284ES 4-wire • • 15mA 15mA max. ZA) @ 12V max 96mA ma 10mA 30v DS2841S 4-wire Isolated • BOpA@ 12V, 1004A max. 100mA max(+/- 100yA max. 10mA) @ 30V DS284THES 4-wire • • e 15mA 15mA max. 96mA max (+/- 2mA) @ 12V (+/- 10mA) @ 30V Detection Systems, Inc. 130 Perinton Parkway, Fairport, New York 14450-9199 (716) 223-4060 • Customer Service (888) 289-0096 *Technical Service (800) 374-7454 • Fax: (716) 223-9180 ISO eooz . U� P/N: 29668H CERTIFICATE NO. A5137 z GENESIS CABLE SYSTEMS Customer Specification Part Number: 4045 Description: 12 AWG 2/C Parallel FPL Compliance: UL Standard 1424- NEC Article 760; CSA FT-4- CSFM Construction: I Conductor 12 AWG 7/0.0305 Bare Copper .IJ Insulation -Jacket PVC - Integral Construction (One leg ribbed for polarity) Insulation Thickness 0.030" nom. g' Insulation -Jacket Color White i Cable Diameter 0.155" x 0.320" nom. Lay Length Parallel Legend (Ink Prim) GENESIS CASLE.SYSTEMS 12 AWG 21C (UL) TYPE FPL E175105 -- C(UL) CMG -- w/os# XXXX FT p Packaging 100`0' Reels Properties "F 17em erature Rating -20 to 75 °C p 9 'I jOperating Voltage 300 Volts max. Capacitance 20 pf/ft nom. 'Impedance 100 Ohms nom. IDC Resistance 1.6 Ohms/M' at 200C 'i F'ame Rating UL Vertical Tray; CSA FT-4 ,I-ustomer Approval: Date: 10i4i00 on GENESIS CABLE SYSTEMS Customer Specification Part Number: 4053 Description: 18 AWG 2/PR STR MID -CAP FPL CABLE Compliance: UL Standard 1424. NEC Article 760; CSFM Construction: Conductor 18 AWG 16/30 Bare Copper No. of Pairs 2 Assembly Each twisted pair is laid parallel and jacketed with a web connecting each jacketed pair. Insulation Type Polypropylene Color Black -Red, Yellow -Green Thickness 0.010" nom. Diameter 0.066 nom. Lay Length 1.5" nom. Jacket Type PVC Color White Thickness 0.018" nom. Diameter 0.160" x 0.370" nom. Legend (Ink Print) GENESIS CABLE SYSTEMS 19 AWG 2/PR (UL) TYPE FPL E175105 - AOCRESSABLE FIRE CABLE - 1.0 z><+FT Packaging 1000' Reels (Properties Temperature Rating -20 to 75 °C Operating Voltage 300 Volts max. Capacitance 15 pf/ft nom. Velocity of Propagation 671/10 nom. Impedance 100 Ohms nom. DC Resistance 6.2 Ohms/M' at 20GC Fiame Rating UL Vertical Tray (Customer Approval: Date: ioNlw R E- (BP01'TER VANE - e ALARM SWITCH WITH RETARD U.S. Pat. No. 3921989 Canadian Pat. No. 1009680 Other Patents Pending Potter Electric, Rd., 1990 GENERAL INFORMATION The Model VSR-F is a vane type waterflow switch for use on wet sprinkler systems. It is UL Listed and FM Approved for use on steel pipe; schedules 10 through 40, sizes 2" thru 8". LPC approved sizes are 2" thru 8" (50mm thru 200mm). The unit may also be used as a sectional waterflow detector on large systems. The unit contains two single pole, double throw, snap action switches and an adjustable, instantly recycling pneumatic retard. The switches are actuated when a flow of 10 gallons per minute or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. ENCLOSURE: The unit is enclosed in a general purpose, die-cast housing. The cover is held in place with two tamper resistant screws which require a special key for removal. A field installable cover tamper switch is available as an option which may be used to indicate unauthorized removal of the cover. See bulletin no. 5400775 for installation instructions of this switch. UL, ULC and CSFM Listed, FM and LPC Approved, NYMEA Accepted, CE Marked Service Pressure: Up to 450 PSI Minimum Flow Rate for Alarm: 10 GPM Maximum Surge: 18 FPS Contact Ratings: Two sets of SPDT (Form C) 15.0 Amps at 125/250VAC 2.0 Amps at 30VDC Resistive Conduit Entrances: Two knockouts provided for 1/2" conduit Environmental Specifications: • Suitable for indoor or outdoor use with factory installed gasket and die-cast housing. • NEMA 4/IP54 Rated Enclosure - use with appropriate conduit fitting. • Temperature Range: 40°F/1200F, 4.50C/49°C • Non -corrosive sleeve factory installed in saddle. Caution: This device is not intended for applications in explosive environments. Sizes Available: Steel Pipe schedules 10 thru 40, sizes 2" thru 8" BS 1387 pipe 50mm thru 200mm Note: For copper or plastic pipe use Model VSR-CF. Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 Optional: Cover Tamper Switch Kit, Stock No. 0090018 INSTALLATION: See Fig.2 These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they should be installed on the top side of the pipe where they will be accessible. The units should not be installed within 6" of a fitting which changes the direction of the waterflow or within 24" of a valve or drain. Drain the system and drill a hole in the pipe using a circular saw in a slow speed drill. The 2" (50mm) and 2 1/2" (65mm) devices require a hole with a diameter of 1 1/4" + 1/8" - 1/16" (33mm ±2mm). All other sizes require a hole with a diameter of 2" ±1/8" (50mm ±2mm). Clean the inside pipe of all growth or other material for a distance equal to the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole; do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterflow. Install the saddle strap and tighten nuts alternately to an eventual 50 ft- Ibs. of torque (see Fig. 2). The vane must not rub the inside of the pipe or bind in any way. Specifications subject to change without notice. Potter Electric Signal Company • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 905-882-1833 • www.pottersignal.com PRINTED IN USA MKT. #8800001 - REV S PAGE 1 OF 2 MFG. #5400761 - 7/00 FIG. 1 SWITCH TERMINAL CONNECTIONS CLAMPING PLATE TERMINAL G G' � DYYC. {923-3 CAUTION: An uninsulated section of a single conductor should not be looped around the termi- nal and serve as two sepa- rate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire becomes dislodged from under the terminal. FIG. 2 VSR-F VANE TYPE WATERFLOW SWITCH WITH RETARD DO NOT LEAVE COVER OFF FOR EXTENDED PERIOD OF TIME RETARD ADJUSTMENT: TO CHANGE TIME TURN KNOB (EITHER DIRECTION) FOR DESIRED TIME DELAY. USE THE MINIMUM AMOUNT OF RETARD NECESSARY TO PREVENT FALSE ALARMS, A "B" SETTING IS USUALLY ADEQUATE FOR THIS. FACTORY IS SET TO "B". L TO INSTALL, DRILL HOLE AS INDICATED: PIPE SIZE HOLE SIZE 2" to 2 1 /2" 1 1 /4" +1 /8" -1 /16" (50mm to 65mm) (33mm ±2mm) 3" to 8" 2" +1 /8" (80mm to 200mm) (50mm ±2mm) DWG. #761-30 FIG. 3 TYPICAL ELECTRICAL CONNECTIONS 2 SETS OF NORMALLY OPEN CONTACTS WATERFLOW ZONE EOLR FROM CLOSE ON ALARM ON FIRE PANEL FIRE PANEL eaR CDW W NC POSITIVE DC THE NC AND NO MARKINGS ON THE SWITCH ARE FOR OR HOT AC AN ALARM CONDITION. THE CONTACTS ARE REVERSED NEGATNE DC OR NEUTRAL AC WHEN THE DEVICE IS IN ONG. V51-2 THE NORMAL CONDITION. DIRECTION OF WATERFLOW [Y] TIGHTEN NUTS ALTERNATELY TO AN EVENTUAL 50FT.—LBS OF TORQUE MOUNT ON PIPE SO ARROW ON SADDLE POINTS IN DIRECTION OF WATERFLOW ROLL PADDLE IN OPPOSITE DIRECTION OF WATERFLOW APPROX. RETARD SETTINGS (IN SECS.) 0 0 1 A 10-25 9 1 20-40 C 35-55 D 50-70 E 60-90 NOTES: 1. The Model VSR-F has two switches, one can be used to operate a central station, pro- prietary or remote signaling unit, while the other contact is used to operate a local audible or visual annunciator. 2. A condition of LPC Approval of this product is that the electri- cal entry must be sealed to exclude moisture. D-3. For supervised circuits see "Switch Terminal Connec- tions" drawing and caution note (Fig. 1). FIG. 4 To remove knockouts: Place screwdriver at edge of knock- outs, not in the center. APPLICATION WARNING! Due to the possibility of unintended discharges caused by pressure surges, trapped air, or short retard times, waterflow switches that are monitoring wet pipe sprinkler systems should not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. TESTING The frequency of inspection and testing for the model VSR-F and its associated protective monitoring system should be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). If provided, the inspector's test valve, that is usually located at the end of the most remote branch line, should always be used for test purposes. If there are no provisions for testing the operation of the flow detection device on the system, application of the VSR-F is not recommended or advisable. A minimum flow of 10 gpm is required to activate this device. IMPORTANT NOTICE: Please advise the person responsible for testing of the fire protection system that this system must be tested in accordance with the testing instructions. PRINTED IN USA MKT. #8800001 -REVS PAGE 2 OF 2 MFG. #5400761 - 7/00 PCVS-19 -2 POTTER CONTROL VALVE ® SUPERVISORY SWITCH EI UL and CSFM.Listed, FM Approved, NYMEA Accepted, CE Marked �I PCVS-1 Stock No. 1010107 I PCVS-2 Stock No. 1010207 The Model PCVS is a weather proof and tamper resistant switch for monitoring the open position of fire sprinkler control valves of the post indicator, butterfly and other types. Depending on the model, one or two SPDT (Form C) contacts are provided which will operate when the valve position is altered from an open state. The unit mounts in a 1/2" NPT tapped hole in the post indicator or butterfly valve housing. The device is engaged by the indicating assembly of the post indicator or the operating mechanism.of the butterfly valve, actuating switch(es) when the valve is fully open. The unit should be installed where it is accessible for service. The cover is held in place by two tamper resistant screws that ORDERING INFORMATION MODEL PCVS-1 - PCVS-2 PBK-S PBK-L PVK Dimensions: 4.75"L x 2.25"W x 7.2"H (stem extended) 12.1 cm L x 5.7cm W x 18.3cm H Weight: 1.35 lb. (.61 kg.) Enclosure: Cover - Die-cast Finish - Red Spatter Enamel Base - Die Cast Zinc All parts have corrosion resistant finishes. Cover Tamper: Tamper Resistant Screws, Optional cover tamper kit available Mounting: 1/2" NPT Contact Rating: PCVS-1: One set of SPDT (Form C) PCVS-2: Two sets of SPDT (Form C) 15.00 Amps at 125/250VAC 2.50 Amps at 30VDC resistive Environmental Limitations: -40OF to +140OF (-40°C to 60°C) NEMA 4 and NEMA 6P Enclosure (IP67) when used with appropriate watertight conduit fittings. Indoor or Outdoor Use (Not for use in hazardous locations. See bulletin no. 5400694 PIVS-U-EX for hazardous locations.) Conduit Entrances: Two knockouts for 1/2' conduit provided. Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 require a special tool to remove. The tool is furnished with each device and should be left with the building owner or responsible party. Replacement or additional cover screws and hex keys are available. See ordering information. OPTIONAL COVER TAMPER SWITCH: A field installable cover tamper switch is available as an option which may be used to indicate removal of the cover. See ordering information. TESTING: The PCVS and its associated protective monitoring system should be tested in accordance with applicable NFPA codes and standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). DESCRIPTION STOCK NO. Potter Control Valve Switch (single switch) 1010107 Potter Control Valve Switch (double switch) 1010207 Cover Screw 5490344 Hex Key for Cover Screws and Installation Adjustments 5250062 Pratt Butterfly Valve Kit (Up to 12") 0090133 Pratt Butterfly Valve Kit (14" and Up) 0090132 Pratt Valve Kit 1000060 Optional Cover Tamper Switch Kit 0090131 For pressure reducer type valve installation kits (if required) contact valve manufacturer. Potter Electric Signal Company • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 905-882-1833 • www.pottersignal.com PRINTED IN USA MKT. #8820001 - REV O PAGE 1 OF 4 9/99 o FIG. 1 3.00 5.20 75 p .85 8.20 ROD RETRACTED 1.20 I AND BREAKAWAY 1 SECTION REMOVED DIMENSIONS 4.75 3.62 II' ' II II II 3.12 II II II ROD EXTENDED u 11 DWG. #980-1 U 0 12 PCVS-1, -2 CONTROL VALVE SUPERVISORY SWITCH FIG. 2 PARTS KN FO' CO TYPICAL INSTALLATIONS ON POST INDICATOR VALVE HOUSINGS (SEE FIGS. 3 THRU 6) Refer to Fig. 2 for the location of parts described in the following instructions. NOTE: If the sprinkler system is in service the owner or authorized representative should be notified, before any work is done on the system, that the valve controlling the water supply to the system may be closed for periods of time during the installation and testing of this device, resulting in all or portions of the system being inoperative during these periods. If the system is not in service and valve is dosed, be sure that opening the valve will not allow any unwanted water flow due to openings in the system, such as heads off, broken or incomplete piping, etc. 1. Position the valve to fully open ("OPEN' should appear in the window of the housing). Partially close the valve while observing the direction that the target assembly moves. Reopen the valve. If the valve housing is predrilled with a 1/2' NPT for installation of a monitoring switch, remove the 1/2" plug and fully open the valve. Makesure that "OPEN" appears in the window of the housing. GO TO STEP NO.6. 2. Remove the head and target assembly (consultation with valve manufac- turer is recommended). 3. If the target assembly moved up as the valve was closed, measure the distance from the bottom of the head to the lower part of the target assembly that will contact the trip rod of the PCVS (see Fig. 3). This is usually a plate or bar on the target assembly, on a side adjacent to the "OPEN/SHUT" plates. Subtract 1/8" from the measurement. If the target moved down as the valve was closed, measure the distance from the bottom of the head to the upper portion of the target assembly that will contact the trip rod of the PCVS (see Fig. 4). Add 1/8" to -this measurement. GROUND SCREW TRIP ROD LOCKING SCREW SOCKET HEAD SCREW NIPPLE LOCKNUT TRIP ROD open end of the nipple to the target assembly. Subtract 1/2" from this measurement. NOTE: In some cases, it may be necessary to attach an angle bracket to the target assembly to engage the PCVS trip rod. 10. Using the special tool provided, loosen the two cover screws and remove the cover from the PCVS. 11. Loosen the locking screw that holds the trip rod in place and adjust the rod length, from the end of the collar to the end of the rod, using the dimension determined in Step 9. Tighten the locking screw to hold the rod in place. NOTE: If trip rod length is excessive, loosen the locking screw and remove the trip rod from the trip lever. Using pliers, break off the one (1) inch long notched section (see Fig. 7). Reinstall trip rod and repeat Step 11 procedure. 12. Partially close the valve (3 to 4 revolutions of the handle/hand wheel). 13. Slide the PCVS unit as far as possible onto the nipple, observing which direction the rod will move when the valve is closed. Orient the device to actuate the switches when the valve is open. Tighten the socket head screw in the collar. 14. Carefully open the valve to the fully open position. As the target moves to the open position it should engage the trip rod and actuate the switch(es). There should be a minimum overtravel of 1/2 revolution of the handle/hand wheel after the switch(es) actuate (a continuity meter connected to each set of contacts is one method that could be used to determine this). 15. Slowly close the valve. The switch must operate during the first two 4. Mark the housing at the proper location. Using a 23/32" drill bit, drill and revolutions of the handle/hand wheel or during 1/5 of the travel distance then tap a 1/2" NPT in the housing on the side that coincides with the of the valve control apparatus from its normal condition. portion of the target assembly that will engage the trip rod of the PCVS. NOTE: Small adjustments of the target position may be necessary 5. Replace the head and target assembly. (consultation with valve manufacturer is recommended). 6. Loosen the socket head screw that holds the nipple in the PCVS and 16. Completethe required electrical wiring, connections and tests. The valve remove the nipple. should be operated through the entire cycle of fully closed and fully open 7. Screw the locknut that is provided onto the nipple. to determine the integrity of the PCVS installation and the signaling 8. Screw the nipple into the 1/2" NPT hole in the valve housing - hand system. Checkthat all electrical and mechanical connections are secure. tighten. Tighten the locknut against the valve housing to secure the nipple 17. When the installation and testing are complete, return valve to its proper ifirmly in place. position. 9. Insert a scale or probe thru the nipple to measure the distance from the 18. Alternative installation for other post indicator valve housing shown in Fig. 5 and 6. I I PRINTED IN USA MKT. #8820001 - REV Q PAGE 2 OF 4 i 9/99 NOTE: In some cases it may be necessary to remove the gear box cover to ensure correct operation (consultation with the valve manufacturer is recommended). B9. Carefully open the valve to its full open position, as the boss on the gear hub moves to the open position it must engage the PCVS trip rod and actuate the switch(es). There should be a minimum overtravel or revolution of the crank or hand wheel after the switch(es) actuate (a continuity meter connected to each set of contacts is one method that could be used to determine this). NOTE: Slight adjustment of gear stops may be necessary to prevent overtravel of the trip rod (consultation with valve manufacture is recom- mended). B 10. Carefully close the valve. The switch(es) must operate during the first two revolutions of the crank or hand wheel or during 1/5 of the travel distance of the valve control apparatus from its normal condition. B11. Complete the required electrical wiring, connections and tests. The valve should be operated through the entire cycle of fully closed and fully open" to determine the integrity of the PCVS installation and signaling system. Check that all electrical and mechanical connections are secure. B12. When the installation and testing are complete, return valve to its proper position. SWITCH TERMINAL CONNECTIONS CLAMPING PLATE TERMINAL FIG. 8 -014 CAUTION: o An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, i uva 99e0-13 thereby providing supervision of the connection in the event that the wire becomes dislodged from under the terminal PRINTED IN USA MKT. #8820001 -REV Q PAGE 3 OF 4 9/99 "-i PCVS-1, -2 iER Pot CONTROL VALVE ® SUPERVISORY SWITCH FIG. 3 FIG. 4 FIG. 5 FIG. 6 METAL PLATE REPLACES 1' GLE!�) E!�) I rf_EL� LOCKNUT j j TARGET I —I MOVES U STEEL UP AS TAMPER TRIPPING SWITCH BLOCK - VALVE UT • REPLACES OH CV C O OPEN • IS SHUT O OPEN• OPEN 0 TAMPER SWITCH MARKER UT • O TARGET MOVES U DOWN AS SHUT TARGETVALVE MARKER IBLE 11 3 8IS SHUT ASSEMBLYDUIT D MOVESTARGET N AS VALVE MOVES HUT UP AS VALVE IS SHUT DWG. #980-30 - Notes: 1. Subject to the approval of the "authority having jurisdiction" the alternate method of installation shown in Fig. 5 maybe used. In this method, one of the glass windows of the housing is replaced with a 1/4" thick metal plate that is cut to fit in place of the glass and drilled and tapped to receive the 1/2" NPT pipe nipple. ;,In some cases it may be necessary to attach an angle bracket to the target assembly to engage the PCVS trip rod. - 2. If the target is stationary. and a hood arrangement is used, such as is shown in Fig. 6, the hood must be drilled with a 23/32" drill and tapped with a 1/2" NPT. The center line of this hole should be 1/8" below the portion of target assembly that strikes the PCVS trip rod. The 11 3/8" dimension shown is for a Clow Valve. Flexible conduit must be used for this type of installation. TYPICAL INSTALLATION ON A BUTTERFLY VALVE (SEE FIGS. 9 AND 10) Refer to Fig. 2 for location of parts described in the following instructions: B1. Remove the 1/2" NPT plug from the gear operator case. B2. Loosen the set screwthat holds the nipple in the PCVS and remove the nipple. 133. Screw the locknut that is provided onto the nipple. B4. Screwthenippleintothe1/2" NPT hole inthe gear operator -handtighten. Tighten the locknut against the case, to secure the nipple firmly in place. B5. Partially close the valve (3 or 4 revolutions of the hand wheel or crank). B6. Using the special tool provided, loosen the two cover screws and remove the cover from the PCVS. B7. Loosen the locking screw that holds the trip rod in place. Estimate trip rod length required and extend slightly past that point. Slide the PCVS unit as far as possible onto the nipple, observing which direction the rod will move when the valve is closed. Orient the device to actuate switches when valve is open. NOTE: If trip rod length is excessive, loosen the locking screw and remove the trip rod from the trip lever. Using pliers, break off the one (1) inch long notched section (see Fig. 7). Reinstall trip rod and repeat Step B7 procedure. B8. Remove device from nipple and withdraw trip rod 1/32" (this dimension is important). Tighten the locking screwto hold the rod in place. Re -install the device on the nipple. Tighten the screw in the collar against the nipple. FIG. 7 BREAKING EXCESSIVE ROD LENGTH ITT GRINNELUKENNEDY INDICATING BUTTERFLY VALVE FIG. 8 F-1 0 ��� • .1fIH5 o m VALVE PARTIALLY CLOSED VALVE OPEN DWG. #980-6 PBK- PRATTIBV BUTTERFLY VALVE KIT FIG. 12 Lot 80' BRACKET AND LOCKNUTS SUPPLIED WITH POK MOUNTING KIT D MODEL PBK-L Stock No. 0090132 (MDT-4S Actuator) MODEL PBK-M Stock No. 0090146 (MDT-3S Actuator) MODEL PBK-S Stock No. 0090133 (MDT-2S Actuator) Pratt Butterfly Valve Kit as used to mount a PCVS on a Pratt Model IBV Valve. Krts contain: Bracket, nuts and instructions Note: This application is subject to the approval of the authority having jurisdiction. DRESSER INDICATING BUTTERFLY VALVE FIG. 10 r- - ,---------------I- 1 e 1 e 1 e I I I I l 0 I 0 I 6 J I I PVK - PRATT PIVA POST INDICATOR VALVE KIT (STOCK NO. 1000060) FIG. 13 MACHINE SCREW { DWG. #9F Pratt Valve Kit as used to mount a PCVS on a Pratt Model PIVA Valve. Kit contains: Instructions, template, screw and nut. Note: This application is subject to the approval of the authority having jurisdiction. PRINTED IN USA MKT. #8820001 -REV O 9/99 r PCVS'1, -2 CONTROL VALVE l SUPERVISORY SWITCH TYPICAL PRESSURE REDUCER TYPE i VALVE INSTALLATION FIG.11 COLLAR LOCKNUT a O NIPPLE _1 PCVS 1/1s/MIN. qa��p GAP DWG. #980-10 This figure shows the Model PCVS mounted on the valve yoke, with a bracket supplied by the valve manufacturer, to supervise a pressure reducer type valve. Note: This application is subject to the approval of the authority having jurisdiction. TYPICAL ELECTRICAL CONNECTIONS Please Note: This device should be wired in accordance with the applicable parts of the National Electrical Code, all state and local codes, applicable NFPA Standards and the requirements of the authority having jurisdiction. FIG. 14 LOCAL CIRCUIT N.O. TO POWER FOR COM. j N.C. INDICATING INDICATING DEVICE ; DEVICE i I TO SUPERVISORY CIRCUIT I N.O. OF CONTROL PANEL ENO OF COM. N.C. LINE RESISTOR DWG. #980-12 Contacts shown in normal (valve open) condition. TYPICAL SWITCH ACTION OPEN VALVE POSITION CLOSED VALVE POSITION COM. N.O. C;CN Sw #1 N, ,C SW #1 I I COM. I N0 Sw #2 SW #1J.0Tt �� DWG. #980-11 Switches Shown in Valve Open Position PAGE 4 OF 4 Qltronix® AL802ULADA provides 8 powerful amps of added signaling power distributed via four (4) class B or two (2) class A supervised output circuits. Equipped with System Sensor®, Gentex®, Faraday and Amseco two -wire horn/strobe sync modes. Allows audible notification appliances (horns) to be silenced while visual notification appliances (strobes) continue to operate. (No sync modules required). AL802ULADA FEATURES: • UL Listed (UL864) Control units for �L Fire Protective Signaling Systems. • CSFM - California State Fire Marshal. • MEA - NYC Department of Buildings. • NFPA 72 Compliant. • Input 115VAC 50/60 Hz, 3.2 amps. • Field selectable 24VDC or 12VDC voltage regulated power limited outputs. • 24VDC or 12VDC rated @ 8 amps max. • Typical 100mV output voltage ripple. • Separate 50mA auxiliary output with built-in and remote reset capability. • Two (2) outputs may be paralleled for more power on an indicating circuit. • Two (2) Class A or two (2) Class B FACP inputs. • Two (2) NC dry contact trigger inputs. • Programmable supervised indicating circuit outputs: Four (4) Class B or Two (2) Class A or One (1) Class A and Two (2) Class B. • 2 wire horn/strobe Sync mode allows audible notification appliances (horns) to be silenced while visual notification appliances (strobes) continue to operate. • Temporal Code 3, Steady Mode, Input to Output Follower Mode (maintains synchronization of notification appliances circuit). • March Time. • Compatible with 12VDC or 24VDC fire panels. • Output loop supervision steered to input 1 or input 2. • Common trouble input and output. • Ground fault detection. • Automatic switchover to stand-by battery when AC Fails. • Zero voltage drop when switching over to battery backup. • AC fail supervision (form "C" contact, I amp 28VDC or 115VAC). Factory set for 1 minute with optional 6 hour delay setting (field selectable). • Battery presence and low battery supervision (form "C" contact, I amp / 28VDC or 115VAC). Making It Work."" 140 58th Street, Brooklyn, New York 11220 • 888.258.7669 9 Fax: 718.567.9056 web site: www.altronix.com • email: info@altronix.com Lifetime Warranty • Made in U.S.A. Gentex is a registered trademark of Gentex Corporation. System Sensor is a registered trademark of Honey SYSTEM SENS®R° GENTEX® FARADAY oud S Typical Application Drawings: Normal or Sync Mode (Class B hookup): sw2 sw, +OUT1— +ouT2— +OUT3— +OUT4— rA From FACP NAC1 EOL 2.2K 2.2K EOL EOL 2.21K EOL Optional paralleled Class B output Optional hookup: EOL Resistor from FACP Fire Alarm Control Panel (FACP) tJ + LT- 4-wire Smoke Detector t1 — F-± t=J + LT- 4-wire Smoke Detector fl _ --± EOL Power Supervision Relay (Not Supplied) C "DRY1" NC UPPER TERMINALS - C "DRY2" NC LOWER TERMINALS To FACP NAC2 EOL or next signaling device or ALS02UL-ADA From FACP NAC2 To FACP NAC1 EOL or next signaling device or AL802UL-ADA Normal or Sync Mode (Class A hookup): swz sw, OUT+OUT 0 @� /"wzw u W00010 PEN -24V ocwseo=�ry 111— j 100 AL801ULE! MM DC 0 AC .- �- ALTRONI%CORP. OC IS A N.O. Reset Switc" ® AUX NO'REMOTE'C ® o,® 00 FAULT AL802LGK s^K CO on", NY RP. F-1 00001 r1r110©0--- 0 ♦00♦ Making It Work.T"" C "DRY1" NC UPPER TERMINALS - C TRIM" NC LOWER TERMINALS From Return FACP to FACP NAC1 From FACP Return NAC2 to FACP Legend Horn )� Strobe A Horn/Strobe Black White Lead Lead 115 VAC/60 Hz, 3.2 amps (Connect to seperate unswitched AC circuit) These circuits are used to monitor AC and Bat Fail and will cause a simultaneous trouble condition to the FACP's IN1 and IN2 Digital Communicator or Local Annuicator Dry output Contact (Form "C" contacts) Addressable Control Module Trigger Output 140 58th Street, Brooklyn, New York 11220 • 888.258.7669 • Fax: 718.567.9056 • web site: www.altronix.com • email: info@altronix.com SS101000Fire 3 0 z 0 z O 0 cc:ccc:c.cc00000000000000c000ccco UL Underwriters Laboratories Inc.,�D Northbrook, IL Santa Clara, CA Melville. NY Research Triangle Park, NC C Camas. 'WA A not -for -profit organization dedicated to public safety and committed to quality service cccccccc; Applicant ID No: 974889-001 Service Center No: 1 Expires: 31-MAR-2002 CERTIFICATE OF COMPLIANCE THIS IS TO CERTIFY that the Alarm Service Company indicated below is included by Underwriters Laboratories Inc. (UL) in its Product Directories as eligible to use the UL Listing Mark in connection with Certificated Alarm Systems. The only evidence of compliance with UL's requirements is the issuance of a UL Certificate for the Alarm System and the Certificate is current under UL's Certificate Verification Service. m n. ` c Listed Service From: BENTONVILLE, AR n n: lu Alarm Service Company(974889-001) Service Center. (974889-001) WAL-MART STORES INC WAL-MART STORES INC ALARM CENTRAL ALARM CENTRAL `. 1105 SE 5TH ST 1105 SE 5TH ST C BENTONVILLE, AR 72716 BENTONVILLE, AR 72716 u The Alarm Service Company is Listed in the following Certificate Service Categories: C. y File - Vol No. CCN Listing Category n• S3152 - 1 UUFX PROTECTIVE SIGNALING SERVICES -CENTRAL STATION r`n u n n. u. u 3 u a e * * * THIS CERTIFICATE EXPIRES ON 31-MAR-2002 In n "LOOK FOR THE UL ALARM SYSTEM CERTIFICATE" f� U �-n I Engineering Manager Z 1998 UL Form CS -CC 5Ml3/98 6-MAR-2001 C u no n. uui n u n u_ u n u W. W'1 Wal-Mart Stores Non -Contiguous Wal-Mart Wal-Mart Fleet Maintenance n� Stores, Inc (contiguous premises) ALARM ice: CENTRAL UL File S3152 r , f, loll I . . ....I,t• Wal-Mart Warehouse #2 L(contiguous premises) rw �r' 1 Wal-Mart "Old CTs Bldg" ;r (non-contiguous premises) = r ;jIr Wal-MartWarehouse #8 i (non-contiguous premises) I ^�J�y;'-'may '_ µ e�•.,....v.- .,✓� 1,^' J✓ � � '11 i Y T 7, I MIA � I ; / • � �F:i •a3�y Wal-Mart's ALARM CENTRAL meets all requirements of a PROPRIETARY SUPERVISING STATION as defined in NFPA 72, 1-4 and specified in NFPA 72, 4-3 (1996) 07 A r m Q n r x a 0 WAL *MART - ELECTRONIC FIRE PROTECTION SYSTEM - PROJECT DOCUMENTATION CODE DESIGN BASIS for DUCT SMOKE DETECTORS NFPA 90A, 4-4.3 ('99) requires that duct smoke detectors "...shall automatically stop their respective fan(s) on detecting the presence of smoke". There is no mandate to shut down any or all other fans within the building, nor is there any requirement that the fan(s) be shut down by anything (such as a fire alarm) other than its respective duct smoke detector. In accordance with NFPA 72, 2-10.3.1 ('99), shutting down an air handling unit via duct smoke detectors is intended "To prevent the recirculation of dangerous quantities of smoke..." - throughout the building. NFPA 90A, Appendix 4-4 reiterates this by stating that "Protection provided by the installation of smoke detectors and related requirements is intended to prevent the distribution of smoke..." . This is logical and essential in most buildings where duct worts -' serves more than one room, space or smoke compartment.. In most Wal-Mart store buildings, each RTU (Roof Top Unit) serves only a very limited amount of duct work, all of which duct work is usually within a single space. The effect is that smoke is extracted from - and returned to - the same space, and therefore, fan shut down in such cases has almost none of the intended benefits. A portion of the expert commentary from the BOCA Mechanical Code serves as an example of this philosophy. Duct detectors for fan shutdown "...should not be applied to installations of air handlers and HVAC equipment which do not involve ductwork and extensive plenums. For example, rooftop HVAC units ... are commonly installed without distribution ductwork. In these examples, the extent of what might be considered as ductwork is typically limited... Because there is no distribution ductwork extending to areas and spaces beyond the immediate location of the HVAC equipment, it is not possible for the HVAC equipment to contribute significantly to the spread of smoke in the building. Therefore, a duct mounted smoke detector would be of little value. " It is an error to consider duct smoke detectors as early fire warning devices, as if they functioned in the way that spot or beam type smoke detectors are typically applied. NFPA 72, 2-10.2 ('99) supports this with the prohibition that, "Detectors that are installed in the air duct system ... shall not be used as a substitute for open area protection. " Just one of the many reasons for this is the ifact that duct smoke detectors do not function when fans are in the OFF cycle. In addition, they are generally not listed for use in the very low air flow velocity present when the fan is not icirculating air. In instances where duct smoke detection can be effective, NFPA 90A, 4-4.2 ('99) requires that they be on the SUPPLY side in systems exceeding 2000 cfm. With only a handful of exceptions, all Wal-Mart stores are single story structures. Under NFPA 90A, an additional duct smoke detector on the RETURN side is required when the system exceeds 15,000 cfm and then ONLY ;f that unit serves more than one story. Logically, there is no meaningful benefit that a RETURN Page 1 of 2 side detector can provide, that is not provided by the SUPPLY side detector. Where the filters might prevent smoke from setting off the SUPPLY side detector, then the fan is obviously not circulatingsufficient smoke e s o e o s as to pose a threat to life safe Additionally, y, RETURN side detectors do not generally provide notice when the fan motor itself, is the source of the smoke. Where duct smoke detectors are required, numerous provisions of the applicable codes and .� standards are often overlooked or are misunderstood. Wal-Mart provides a supervisory signal at the constantly attended location within the store (the customer service desk or equal) AND sends - such signals to the 24 hour off -site supervising station. This is done in accordance with NFPA 72, 3-9.5.3 ('99) which states that "Smoke detectors mounted in the air ducts of HVAC systems shall initiate either an alarm signal at the protected premises or a suQervisory signal at a constantly attended location or supervising station." Wal-Mart does not designate duct smoke detectors to initiate an "alarm" which is compliant with NFPA 90A, 4-4.4.2 ('99) which reads, "Smoke detectors used solely for... heating, ventilating, and lair -conditioning system shutdown shall not be required to activate the building evacuation alarm" In accordance with NFPA 72, 2-10.5.8 Exception ('99), remote alarm indicators for duct smoke _detectors are not required "...where the specific detector in alarm is indicated at the control unit." Wal-Mart systems provide point identification of each duct smoke detector, in a plain English, alpha -numeric display with audible sounder, at each remote annunciator station on the premises. CONCLUSIONS i 1) Unless specifically required by a legally applicable provision from OTHER THAN NFPA or BOCA codes and standards, most HVAC systems in Wal-Mart stores should not be required to include ANY duct smoke detectors. When such detectors are included, these should be 1 considered as an elective by the building owner, and treated as "supplementary" devices as defined in NFPA 72,, Section 1-4 ('99) Unless specifically required by a legally applicable provision from OTHER THAN NFPA or BOCA codes and standards, most HVAC systems in Wal-Mart stores should not be required to include RETURN SIDE duct smoke detectors. When such detectors are included, these should be considered as an elective by the building owner, and treated as "supplementary" devices as defined in NFPA 72, Section 1-4 ('99). Unless specifically required by a legally applicable provision from OTHER THAN NFPA or BOCA codes and standards, duct smoke detectors in Wal-Mart stores should cause a "supervisory" signal, and should not be required to cause a building evacuation. 4) Unless specifically required by a legally applicable provision from OTHER THAN NFPA or i BOCA codes and standards, duct smoke detectors in Wal-Mart stores should not be required to include remote alarm indicators, rather, they shall be specifically identified and indicated at all remote annunciator stations, and shall signal to the off -site monitoring station. Page 2 of 2 (REV091500) 02 Features • Outside mounting tabs • Patented telescoping sampling tube • Built-in reset button • Interconnectability* for multi -fan shutdown (up to ten air handlers) • Patented cover tamper trouble signal • Easy to clean • 24 VAC/DC or 120/240 VAC operation • High -Low voltage barrier • Ion or photo models available • Remote test station option • Remote sounder option • Air velocity rating from 500 to 4000 FPM • Equipped with two DPDT Form C relay contacts • Easy and quick mounting to round or rectangular ducts from 1'-12' wide • Textured cover for convenient visual inspection • UL 268A listed • 3-year warranty Specifications N'lodels Available DH100ACDC14wire Ionization Detector DH100ACDCP 4-wire Photoelectronic Detector System Sensor DH100ACDC 4-wire duct smoke detector is available as either an ionization or photoelectric model. This new design allows for simplified cleaning and maintenance, or a change in application without removing the duct housing. The DH100ACDC samples air currents passing through a duct and gives dependable performance for management of fans, blowers, and air conditioning systems, preventing the spread of toxic smoke and fire gases through the protected area. WARNING: Duct smoke detectors have specific limitations. DUCT DETECTORS ARE: NOT a substitute for an open area smoke detector, NOT a substitute for early warning detection, and NOT a replacement for a building's regular fire detection system. Refer to NFPA 72 and 90A for additional duct smoke detector application information. Length: 141/8 inches (37 cm.) Operating Width: 51/2 inches (14 cm.) Humidity Range: 10% to 9 3 % relative humidity Depth: 23/4 inches (7 cm.) noncondensing Shipping Weight: 3.75 lbs. (1.7 kg.) Air Duct Velocity: 500 to 4000 ft./min. Operating Temperature Range: Photoelectric: 32' to 131' F (0' to 55' C) Ionization: 32' to 120' F (0' to 49' Q * Patent pending APPROVED m System Sensor 7/99 This document is not intended to be used for installation purposes. A05-977-02 Architectural/Engineering Specifications The air duct smoke detector shall be a System Sensor Model DH100ACDC Series Duct Smoke Detector. The detector housing shall be UL listed per UL 268A specifically for use in air handling systems. The detector shall operate at air velocities of 500 feet per minute to 4000 feet per minute. The unit shall be capable of controlling up to ten (10) air handling systems when interconnected with other detectors. The detector shall be capable of providing a trouble signal in the event that the front cover is removed. It shall be capable of local testing via magnetic switch or remote testing using the SSK451 Multi -Signaling Accessory or the RTS451KEY Remote Test Station. The unit shall be reset by local reset button or remote test station. The duct smoke detector housing shall incorporate an airtight smoke chamber in Whrin� Guide System wiring diagram for 4-wire duct smoke detectors compliance with UL 268A, Standard for Smoke Detectors for Duct Applications. The housing shall be capable of mounting to either rectangular or round ducts without adapter brackets. An integral filter system shall be included to reduce dust and residue effects on detector and housing, thereby reducing maintenance and servicing. Sampling tubes shall either be telescoping or be easily installed by passing through the duct housing after the housing is mounted to the duct. The unit shall provide a spacial separation of no less than 1/4' and/or a physical barrier between the high and low voltage terminals. The enlosure shall meet all applicable NEC and NFPA standards regarding electrical junction boxes. Terminal connections shall be of the strip and clamp method suitable for 12-18 AWG wiring. AVAILABLE POWER INPUTS I AVAILABLE POWER INPUTS I CONNECT POWER SOURCE POWER INPUTS ACCEPT I 9 10 A B C I I 9 10 A B C I TO APPROPRIATE TERMINALS 24 VDC, 24 VAC 50-60 HZ, OF EACH DETECTOR. SEE -- 120 VAC AC 5 HZ,-60 OR I I 1 I SPECIFICATIONS FOR CONNECT VAC WE HZ. ADDITIONAL POWER SUPPLY & & & y TO APPROPRIATE SOURCE I } } I TO APPROPRIATE TERMINALS L J [VA 0L�120 INFORMATION.OF EACH DETECTOR. 24V I I 24V VAC 1 220/240 I 1 220/240 1 VAC I I VAC 1 ALARM AUXILIARY CONTACTS I ALARM AUXILIARY CONTACTS FOR FAN SHUTDOWN, ETC. I FOR FAN SHUTDOWN, ETC. I AUX. CONTACT RATINGS 1 16 6 17 7 18 8 I 1 16 6 17 7 18 8 1OA @ 30 VDC RESISTIVE 10A @ 250 VAC 1 ( 1 1 FOR WIRING OF AUXILIARY III 100mA MINIMUM @ 5 VDC I N.C. C. N.O. N.O.UNC. 1 I N."C2. N.O.UNC. I DEVICES, REFER TO - NOT INTENDED FOR MANUFACTURER'S CONNECTION TO CONTROL I I I I INSTALLATION INSTRUCTIONS PANELS. OR CONTACT MANUFACTURER. ALARM AUXILIARY CONTACTS SHOWN IN 1 I ALARM AUXILIARY CONTACTS SHOWN IN 1 NOTE: THE SUPERVISORY RELAY NOW STANDBY.INDICATEDCONTACTS TTDURING I STANDBY.INDICATED TTDURING PROVIDES A "FORM C" CONTACT FOR ALARM AS BY HE ARROWSALARM AS BY HE ARROWS CUSTOMIZED APPLICATIONS. 1 I 1 I FOOE NO' STANDARD CONTA APPLICATIONS, ONLY TROUBLE CONTACT RATING SUPERVISORY TROUBLE CONTACTS SUPERVISORY TROUBLE CONTACTS _ 2.0 A@ 30 VDC resistive I 14 3 I 14 3 ITROUBLE CONTACTS CLOSED IN ATARM AND S TROUBLEC NTACTSC ED IN ALARM AND STAND I CONTACTS OPEN WHILE DETECTOR PCB OR POWER IS I I CONTACTS OPEN WHILEODETECTOR PCB OR POWERS REMOVED OR WHEN TAMPER FEATURE TIMES OUT. OPEN REMOVED OR WHEN TAMPER FEATURE TIMES OUT. OPEN 1 CONTACTS SIGNAL TROUBLE CONDITION TO PANEL. CONTACTS SIGNAL TROUBLE CONDITION TO PANEL. 1 1 5 5 I ALARM ALARM CONTACTS SHOWN ALARM CONTACTS SHOWN INITIATION INITIATION OPEN IN STANDBY. INITIATION OPEN IN STANDBY. LOOP CONTACTS CONTACTS CLOSE CONTACTS CONTACTS CLOSE IN ALARM. IN ALARM. 4 4 I I I I I L__----_------I UL LISTED 4-WIRE FIRST DETECTOR IN THE LOOP LAST DETECTOR IN THE LOOP EOL RESISTOR CONTROL PANEL DH100ACDC DH100ACDC SPECIFIED BY PANEL MANUFACTURER Page 2 Electrical Ratings ® DH100ACDC (includes Detector) Power supply voltage: 20-29 VDC 24 VAC 50-60-Hz 120 VAC 50-60 Hz 220/240 VAC 50-60 Hz Input capacitance: 270 µF max. 270 µF max. N/A N/A Reset voltage: 3.0 VDC min. 2.0 VAC min. 10 VAC min. 20 VAC min. Reset time (with RTS451): .03 to 0.3 sec. .03 to 0.3 sec. .03 to 0.3 sec. .03 to 0.3 sec. Reset time (by power down): 0.6 sec. max. 0.6 sec. max. 0.6 sec. max. 0.6 sec. max. Power up time: 34 sec. max. 34 sec. max. 34 sec. max. 34 sec. max. Alarm response time: 2 to 17 sec. 2 to 17 sec. 2 to 17 sec. 2 to 17 sec. Sensitivity Test: See detector label See detector label See detector label See detector label Power Supply Voltage 20 - 29 VDC 24 VAC 50 - 60 Hz 120 VAC 50 - 60 Hz 220/240 VAC 50 - 60 Hz CURRENT REQUIREMENTS (USING NO ACCESSORIES) Max. standby current 15 mA 35 mA RIMS 25 mA RMS' 15 mA RMS' Max. alarm current 70 mA 125 mA RMS 35 mA RMS" 25 mA RMS' CONTACT RATINGS Alarm initiation contacts (SPST) 2.OA @ 30 VAC/DC (0.6 power factor) Alarm auxiliary contacts (DPDT) 10A @ 30 VDC 1 OA @ 250 VAC Note: Alarm auxiliary contacts must switch 100mA minimum at 5VDC. Alarm auxiliary contacts shall not be connected to inititaing circuits of control panels. Use the alarm initiation contact for this purpose. Trouble contacts (SPOT) 2.OA @ 30 VDC (resistive) Wiring diagram for DH100ACDC to APA451 DH100ACDC Alarm Signal 15 Aux. Power+ 19 Sup. N. O. 14 Sup. COM 3 Aux. Power — 20 APA451 Alarm Power Common NOTE: Wiring diagram shown is for DH100ACDC 4-wire duct smoke detector system equipped without a control panel. NOTE: A trouble condition is indicated when the green LED is not illuminated. Wiring diagram for DH100ACDC to SSK451 and interconnect feature FIELD INSTALLED JUMPER FOR TEMPORAL PATTERN COMMON,' TEMPORAL SELECT' ALARM SIGNAL SUPERVISORY SIGNAL RESET TEST POWER (-) POWER (+) SSK451 FIELD INSTALLED JUMPER ALARM SIGNAL SUPERVISORY 1 CONTACT RESET TEST AUX. POWER (-) AUX. POWER (+) INTERCONNECT + INTERCONNECT - UNIT 1 12 INTERCONNECT+ 1 INTERCONNECT- DH100ACDC UNIT 2 Coil Note Please note that the magnetic coil supplied with the RTS451 and RTS451KEY is not required when these accessories are used with the DH100ACDC detectors. The functionality of the magnetic coil has been designed into the circuitry of the new InnovairT" duct smoke detectors. ACCESSORY CURRENT LOADS AT 24 VDC DEVICE STANDBY TROUBLE ALARM APA451 12.5mA Max. n/a 30mA Max. PA400 OmA n/a 15mA Max. RA40OZ OmA n/a 1 OmA Max. RTS451/RTS451KEY 12mA' n/a 7.5mA Max. SSK451 5mA Max. 9mA Max. 30mA Max. 'NOTE: When a unit is powered at the 120VAC or 220/240VAC input, any combination of accessories may be used such that the given accessory loads are: 60 mA or less in the standby state; 110 mA or less in the alarm state. Important Interconnect Notes e When using the interconnect feature, all interconnected units must be powered with the same, independent supply. • Polarity must be maintained throughout the interconnect wiring. Connect terminal 12 on unit 1 to terminal 12 on unit 2 and so on. Similarly, connect terminal 1 on unit 1 to terminal 1 on unit 2 and so on. Wiring diagram for the RTS451/RTS451KEY and interconnect feature DH100ACDC Alarm Signal 15 - - - - - Aux. Power + - 19 - - Sup. N. O. I 14 I Sup. COM 3 Aux. Power — 20 Reset 2 Test 11 Interconnect — OE Interconnect+ Unit 1 12 DH100ACDC UNIT 2 Interconnect — (1- -Interconnect + 12 RTS451/RTS451KEY 1 (Red LED) Alarm 6 (Green LED) Power I I *NOTE: For RTS451 KEY only without a Control Panel. Page 3 A05-977-02 Ordering Information Part No. Description SSK451 Multi -Signaling accessory DH100ACDCI 4-wire ionization duct detector RTS451KEY Remote test station with key lock (see below) DH100ACDCP 4-wire photoelectronic duct detector RTS451 Remote test station A5052 Replacement ionization detector board APA451 Remote annunciator with piezo alarm A5069 Replacement photoelectronic detector board MOD40OR Sensitivity test module A5064 Replacement 4-wire power board RA40OZ Remote annunciator alarm LED (see below) Accessories F36-09-00 Replacement air filters (two per package) ST-1.5 Metal sampling tube duct widths 1'-2' M02-04-00 Test magnet ST-3 Metal sampling tube duct widths 2'-4' P48-21-00 End cap for metal sampling tubes ST-5 Metal sampling tube duct widths T-8' S08-39-01 Photo replacement screen ST-10 Metal sampling tube duct widths 8'-12' PA40OW Mini -Alert sounder T80-71-00 Replacement telescoping sampling tube PS24LO Mini -Alert add -on strobe P48-55-00 Replacement end cap for T80-71-00 PS12/24LENSC Ceiling -mount "SMOKE" lens PS12/24LENSW Wall -mount "SMOKE" lens Accessories System Sensor provides system flexibility with a variety of annunciation. As with our duct detectors, all duct detector accessories, including two remote test stations, and several accessories are UL listed. different means of visible and audible system R APA451 RTS451KEY PA400 with RTS451 RA40OZ Piezo Remote Test PS24LOW Add -on Strobe Remote Test Remote Annunciator Station with Key (PS12/24SLENSW Station Annunciator (UL S4011) (UL S2522) smoke lens option available) (UL S2522) (UL S2522) (UL S3593) O O loll o 0000 Ormer- Oo a"GoO 0 00000000 O 00 0000000 0000000000 .000000000 00"000000 0000000000 0000000000 0 0 System Sensor Sales and Service O O o o 0 M 0O O0 00 0 00 0o O 00 00 00 0 00 00 �Mw SSK451 SSK451 with PS24LOW Strobe and PS12/24SLENSW "SMOKE" Lens System Sensor Headquarters System Sensor Canada: System Sensor China: System Sensor -Far East 3825 Ohio Avenue Ph: 905.812.0767 Ph: 011.86.295.246.253 Ph: 011.852.2191 St. Charles, IL 60174 Fx: 905.812.0771 Fx: 011.86.295.246.259 Fx: 011.852.2736.6580 Ph: 800-SENSOR2 Fx: 630/377-6495 System Sensor UK: System Sensor in Singapore: System Sensor -Australia Documents on Demand Ph: 011.44.1403.276500 Ph: 011.65.273.2230 Ph: 011.613.54.281.142 1-800-736-7672 x3 Fx: 011.44.1403.276501 Fx: 011.65.273.2610 Fx: 011.613.54.281.172 Web: www.systemsensor.com Page 4 A05-977-02 0 m v O 0 m a m y N v 0 0 c rn r m D O Z j CITY OF SANFORD MECHANICAL PERMIT APPLICATION Permit Number: Date: 6eO'j&4f A d&R7o- ✓ 9-14qGJ 67o v,- The undersigned hereby applies for a permit to install the following equipment: Owner's Name: Aqps E 4+ Address of Job: �, 1,7 9 Q� Mechanical Contractor:Zr Residential Non -Residential X Amount Nature of Work: G Oat% l..L T f Job Valuation: Application Fee: $10.00 TOTAL DUE: VC(rJ By signing this application, I am stating that I am in compliance with City of Sanford Ov v Mechanical Code. Ar ApplicAt Signature State License Number W4 " 9oLi - (a3b g3o3 BUILDING AND ZONING DEPARTMENT AUTHORIZATION FOR AGENT Date L, do hereby authorize my employee, ( Contractor name) Glenn Lam>,ien to act as my agent in securing permits for Sunbelt Equipment ( Employee name) Sales, Inc. I understand I am responsible for any and all work preformed by my agent. I am also Aware. that I will be responsible for the renewal of this form annually. OF Contractor Signature ( State Certification Number ) State of° b, County of The foregoing instrument was acknowledged before me this ( Date by � °H" //"V�c� who is personally known to me or has produced as identification. ( Agents. Name) i�r"6ue"% GWENDOLYNFAYLAHEM ` " c� . Notary Public -State of Fioddc MycommraionBpi'esMay31,7�4 _mac y. Comm on # CC941005 ( Notary and Commission) ` ( Agent / Employee Signature) State of Countyof The foregoing instrument was acknowledged before me is ( Date ) by 6tt—`�l, � N � L 4m ewho is personally known to me or has produced as identification. — A ( Agents NamePK" GWENDOLr4 FAY LAHERA �c Notary Puuiic - State of Florida ,,!;yCammssronEPimMay31,Z004 - G`Ms�f a�F Commission # CC941WS ( Notary and Commission) `'`"p I I5Z.1 .FcP;Gi �:N"E� dGUI ':a.RG; SJ,TE n.1G' D .L_ r x °.C: Date: No. of pages incluting cover sheet: From: Hun,. 8� o ner, Inc`. Phone: (21 4) 760-7000 Fax phone; t214i 760.7060 _ IM IF REMARKS: J Urgent For your review Repiy ASAP COMMENTS: Please comment Tr Decllr�(lll', Ra�rnTT `. �T..iG,zs and Assoc. 21474906Q1 El- r� Post-Ir Faj Note 7671 %2.4] (,'I paeesd :Ro r s GaIce. Phone C Rue k Fax Y aK .... W-A L- I` i - RZQLMFOR (YFORMATION SUP'ERCMER DATE: TdPt Nt?: IZ TO: Pwinand H. Hanna Att:hitect FAX (Z 14) 749-060 PROJECT. (Cesare! Coturecusr) ""�"" Stora q (i�rolect Supermtettd tom""' (Ciry, Stato) S; ECIFIOATION SECTION: a-� �� • Numbxr (Job Sue e Pbot►W- 1kM,�GIDETAIL: _... (J�- {te Fax Romer} This request has been rewgfwad by **.WW-I Mott slams, bc: C4tbcnxtttlw M'apag�t Y�5 INFORMATION REQUESTED. 4 � �rL Requested y, �f Vsin W o► --T--�-•------•��...__ �?r,?A�0 wnsag td By 'i , Deta REPLY` a p Q t I,Y I r{ n � p fiJ+c ttcPa response sha{E oot Os Cop red m .ontrtttt 5 "01 CotfEreet T' e e t7 Ot 1 .ettEe Dtrectide, tter osa u"a _ art:b c ranges in ,e O{15�-3 F��nter Exputsicn #9Sf - SanfordFL fagv j October 3, 3DE10 _ tJl u6ga `Wdlt:z .0-ce-Qvp •9BBB�{gaLL 9 e ; _ . OAfI SMV 18 NOitibHU :AB iue9 CITY OF SANFORD ELECTRICAL PERMIT APPLICATION Permit Number: '01 - a 0 6- Date-- _71°1./01 'The undersigned hereby applies for a permit to install the following electrical: Owner's Name: Na%, -u- t AAr2z-T- Address of Job. - Electrical Contractor: Residential: Non -Residential:_ Number.. Amount Addition, Alteration, Repair Residential & Non -Residential`' New Residential: By Signing this application I am stating that l am in compliance with City of Sanford Electrical Code. App icant's'Signature ��OO�c��715 State License Number` POST TENSIONING/STEEL REPORT w TM 4Y H O R Yr P R O P E R T Y S C I E N C E S 598 S. North take Blvd., Suite 1024 / Altamonte Springs, Florida 32701 / 407-645-3400 407-645-3731 PROJECT: Wal-Mart Store #857 CMT Services Americana JOB NO: 9097 Blvd. & Us 17/92 Sanford FL CLIENT: Wal-Mart Store, Inc. REPORT NO: 111078 TECHNICIAN: Ronald Kersey DATE OF EVALUATION: October 25, 2001 SECTION: 1458-3.6 WEATHER CONDITIONS: Partly Cloudy SUMMARY OF WORK PERFORMED: As requested, a QORE Property Sciences representative arrived on site and observed reinforcing steel at the north Loading Dock, west retaining wall footing. The reinforced steel observed appears to be in general accordance with the projects drawings and specifications with regards to bar size, length, spacing, quality and cleanliness. COPIES TO: Wal-Mart Store, Inc. / MS Laurie Demers (1) CPH Engineers, Inc / MS Diana Greene (1) Pinkerton & Laws / MR David Morton (3) Florida n-! , P.E. on No. 48574 CITY OF SANFORD, FLORIDA APPLICATION FOR THE DEMOLITION AND REMOVAL JUL 9.20.01 OF BUILDINGS AND STRUCTURES g PERMIT ADDRESS 3(a S. oR-4ontp -t —• . PERMIT NUMBER 9 TOTAL CONTRACT PRICE OF DEMOLITION �QQr] _ TOTAL SQUARE FT. TAX PARCEL NUMBER 5 i 1 ro,.4 2,0 OWNER AL WW2-1�Si�i�-�� I..IC... PHONE NUMBER �'0I rl�, . L000 ADDRESS act 1 i IC�� S� 1�C�.wl►i r4R CITY 3Ci.i;a,jV1�,t►� STATE ZIP i2-11 G CONTRACTOR �I,a,�L�"i'1� eiL�S trlC� PHONE NUMBER LJCr`)-6•S 4 ADDRESS -jp\ ps , LAC , ��i1.•1�( i7tlr '�30 \ ST. LICENSE NUMBER -03-Q. Z CITY MAC �LA,S �� STATE �: ` ZIP y TYPE OF STRUCTURE TO BE DEMOLISHED: FRAME CONCRETE BLOCK STEEL ✓ OTHER; PREVIOUS USE OF BUILDING OR STRUCTURE PROPOSED USE OF THE SITE 2erAil-f:6a, ZaZ 4- GAS COMPANY DISCONNECT NUMBER (IF APPLICABLE) GAS COMPANY PERSONNEL ISSUING NUMBER NOTE: GAS COMPANY SECTION MUST BE COMPLETED BEFORE DEMOLITION PERMIT WILL BE ISSUED. THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION'AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS'OR IF CONSTRUCTION OR WORK IS SUSPENDED OR.'ABANDONED FOR A PERIOD OF 180' DAYS AT ANYTIME AFTER .THE WORK IS COMMENCED. IN ADDITION TO THE REQUIREMENTS OF THIS PERMIT, THERE MAY BE ADDITIONAL RESTRICTIONS APPLICABLE TO THIS PROPERTY THAT MAY BE FOUND IN THE PUBLIC RECORDS OF THIS COUNTY, AND THERE MAY BE ADDITIONAL PERMITS REQUIRED FROM OTHER GOVERNMENTAL ENTITIES SUCH AS WATER MANAGEMENT DISTRICTS, STATE AGENCIES, OR FEDERAL AGENCIES. THE NAMED CONTRACTOR/OWNER BUILDER TO.WHOM THE PERMIT IS ISSUED SHALL HAVE THE RESPONSIBILITY FOR SUPERVISION, DIRECTION, MANAGEMENT, AND CONTROL OF THE CONSTRUCTION ACTIVITIES ON THE PROJECT FOR WHICH THE BUILDING PERMIT WAS ISSUED. OWNER'S AFFIDAVIT: I CERTIFY THAT ALL THE FOREGOING INFORMATION IS ACCURATE AND THAT ALL WORK WILL BE DONE IN COMPLIANCE WITH ALL APPLICABLE LAWS REGULATING CONSTRUCTION AND ZONING. A"COPY OF THE RECORDED COPY OF THE NOTICE OF COMMENCEMENT WILL BE POSTED ON THE JOB SITE WITH PERMITS NO.LATER THAN SEVEN ('7) DAYS AFTER THE PERMIT HAS BEEN ISSUED. FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY-RESULT.IN YOU PAYING TWICE FOR THE IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE.OF-COMMENCEMENT. ASBESTOS NOTIFICATION STATEMENT (SEC. 553.79(11), FL STATUTES) FOR FACILITIES OTHER THAN SINGLE FAMILY OR DUPLEX HOUSING. I HEREBY AFFIRM THAT J HAVE COMPLIED WITH THE PROVISIONS OF SECTION 455-302, FL STATUTES, AND HAVE NOTIFIED THE DEPARTMENT OF ENVIRONME TAL REGULATION OF MY INTENTIO TO REMOVE ASBESTOS, IF APPLICABLE. wit. - I s 2 , N(. SIGNATURE OF OWNER/AGENT &. DATE SIGNATURE 0 CONTRACTOR & DATE ~ TYPE OR PRINT WNER/AGENT NAME TYPE OR PRINT CONTRACTOR'S NAME o SIGNATURE OF NOTA & DA Y SIGNATURE OF NOTARY & DATE a (OFFICIAL SE ) AOFFICIAL SEAL) a y SHEILA GUM o Notary Public Cobb Courtly,GeMA !� Ccmruitis 99 Expires July.27 2004' R a 3 0 � a i Z >,Q APPLICATION APPROVED BY DATE /11 I o FEES: BUILDING APPLICA ION OTHER o � � PERMIT VALIDATION: CHECK CASH DATE %�L�( BY Z a F ORIGINAL (BUILDING) YELLOW (CUSTOMER) _ PINK (COUNTY TAX OFFICE) 0I�a Florida Department of otr�«+„uss�soopt EfkrrM:_— i ... Environmental Protection rate r a i RORIDA RDWisiov of Arc Resource Management NOTICE OF ASBESTOS RENOVATION OR DEMOLITION TYPE OF NOTICE (CHECK ONE ONLY) )0 ORIGINAL D REVISED ❑ CANCELLATION . 0 COURTESY TYPE OF PROJECT (CHECK ONE ONLY): X DEMOLITION X RENOVATION - Retail Shops Demolished IF DEMOLITION, IS IT AN ORDERED DENIOUTION? ❑YES VNO — Walmart Store Renovated IF RENOVATION; IS IT AN EMERGENCY RENOVATION OPERATION? 0 YES 0 N0. S NO 15 IT A PLANNED RENOVATION OPERATION? I. Facility Name wa1 art. to e 857 Address C cm i n n l P 2 . G.�r.a State_'T. Zip 32771 _ County city - Site Consultant Inspecting Site 00 Building Size _ (Square FeeO # of Floors _�Age in Years 17 _ w& Retai �.Spaces Prior Use: 0 School/College/Universiry D Residence 0 Small Business XOther a 1 mart _ Present Use: ❑ SchooVCollege/Universlty ❑ Residence 0 Small Business JQ Other y?a i mart & Retail Spaces II. Fadliryowner W&lm§Lrt . stores Inc. Phrm(5.p.1) 27 i-4 (l(I Address 7 2716- 0 5 5 0 City _ R n tnny i 1 State AR zip — III. Contractor's Name Pinkerton & Laws Inc. ► Phone 40 Address 9 (11 1N� z T v n St my City _ srt i f- t3 State F T C Zip 3 7 7 7 4 ,-•rr �r�� Is the contractor from licensure under section 469.00a(n, F.S.? , ❑ YES Florida License No. yp NO IV. Scheduled Dates: (Notice must be postmarked 10 working days before the project start date) _ Asbestos Removal (mm/dd/yy) Sta►t:j2-1-01 Finish: 12-5-01 Demo/Renovation(mm/dd/yy) Start: — — Finish: 1-1-02 V. Procedures to be Used (Check All That Apply): �Buildozer Wrecking Bal I Strip and Removal Glove Bag •DryMethodWet Method plode Burn Down pTHER: •MUST OBTAIN PRIOR DEP APPROVAL BEFORE USING A DRY METHOD will not OCCUr VI. Procedures for Unexpected RACM: Due to work Practices Friability Phone407 )294-8551 VIL Asbestos Waste Transporter. Name _jiA�,AtI m3ti c �y� L— Address City State F zip 3 2 8 0 E ,ate; � 1 Class CND � a T.,„ Vill. Waste Disposal Site: Name ec nla - -- Address State, _ __zip 32710 city — „ e. - t.,—;—will RP Sent to Address In Block Below: (Print or Type) IX. Amount of RACM or ACM square feet surfacing material linear feel pipe cubic feet of RACM off facility components square feet cementitious material 3 6 4 6 square feet resilient` flooring square feet asphalt roofing I Certify that the above information -is correct and that an individual trained in the provisions of This regulation (40 CFR Part 61, Subpart M) will be on rile duri the emolitton or renovation and evidence that the required training has been accomplished by th1 er av le f r 'ns lion during normal business hours. ` O' (Date) b (Signature of Owner/Operator) - DEP USE ONLY Po,tm::.jrldDate Received ID# 1r)kl. VIJ.1 11.1 )C-Tfi T11.J Tnn2_an—inf` �Rx Day T► NEj R 15, 50 = 8-14-201 3:53AM FROM P. 2 CITY OF SANFORD MECHANICAL PERMIT APPLICATION l r Permit Number: `' Date: I The undersigned hereby applies for a permit to install the following equipment: Owners Name: Address of Job: ' /G3�:N�. ,•�✓ 11.i�il�f�C Mechanical Contractor: A4GUw, Residential Non -Residential w�F`�..�`.� . Nature of Work: yvdc I 1fP1V,7V1941'0,1- f C',r PAPS 'uti ►^ V C 3 C i9 5Q /. o ,, E -17 NjVlf F,4 u� Job Valuation: Application Fee: $10.00 TOTAL DUE: By signing this application, I am stating that I am in compliance with City of Sanford Mechanical Code.- r Applicant Slgnalure State License Number REVISIONS PERMIT # ADDRESS 3 C-Ss3 ®� CONTRACTOR DATE PH # IFAX # DESCPRITION OF REVISION: =L(1 UTIL FIRE B L D � � 0 i i CONSTRUCTION CHANGE DIRECTIVE #7 PROJECT 99127 207 WAL MART SUPERCENTER EXPANSION #857 SANFORD, FLORIDA 3653 ORLANDO DRIVE SANFORD, FL 32773 February 19, 2002 RAYMOND H. HARRIS ARCHITECT REG. NO. AR0014269 211 NORTH RECORD STREET, SUITE 222 DALLAS, TX 75202 (214) 749-0626 WAL MART STORES, INC. CONSTRUCTION DEPARTMENT WAL-MART REALTY DIVISION 2001 S. E. 10T" STREET BENTONVILLE, AR 72712. ATTN: MR. MARK CASPERMEYER, CONSTRUCTION DIRECTOR TO: PINKERTON & LAWS COMPANY 1165 N. CHASE PARKWAY SUITE #100 MARIETTA, GA 30067 REASON FOR CHANGE: This change is to finish the Bank Space per Wal-Mart Bank Space Finish -Out Report #17 dated January 8; 2002. Contained herein are the changes to the Drawings and Specifications for the above -referenced Project. The General Contractor shall obtain approval of the Wal-Mart Construction Manager before beginning the Work as defined in this Construction Change Directive. If applicable, adjustment to the Contract sum may be based only on the method described in 7.3.3.1 of the Contract. A response to this Construction Change Directive shall be returned to the Construction Manager within 21 days as per the Construction Contract. The Construction Documents are hereby amended in the following particulars, Page 1 through 2 of 2 and Sheets A5.5, A7, M2, E1.1, E2.1, E3.2-1 E4, dated February 7, 2002. ARCHITECTURAL 1. SHEET A5.5: a. Revise plan 1-A5.5 for Bank Space Finish Out as shown as shown. b. Revise Elevation 2/A5.5 for Bank Space Finish Out as shown. 2. SHEET A7: a. Add window Type D as shown. b. Revise Room Finish Schedule as shown for Bank BT1. C. Revise Door Schedule to add Door 800. ELECTRICAL 1. SHEET E1'.1: a. Add lights and Grid for bank.. j Page 1 of 2 i ,.",--CONSTRUCTION CHANGE DIRECTIVE #7 0 i i PROJECT 99127 2000 WAL MART SUPERCENTER EXPANSION #857 SANFORD, FLORIDA 3653 ORLANDO DRIVE SANFORD, FL 32773 2. SHEET E2.1: a. Add receptacles and circuitry of bank. 3. SHEET E3.2: a. Add panelboard LIB. 4. SHEET E4: a. Add panelboard LIB feeder in existing conduit. MECHANICAL 1. SHEET M5: a. Add HVAC for RTU6. END OF CONSTRUCTION CHANGE DIRECTIVE #7 Page 2 of 2 Signs (.0 Lights Storm Sewer Driveway, Street Work 4 FEES PAID DESCRIPTION Dom",;.,: AMOUNT WATER -SEWER IMPACT FEES 01-APPLCTN FEE -ELECTRIC 7/03/01 10.00 01-APPLCTN FEE -BUILDING 6/27/01 10.00 01-APPLCTN tEt-MECHANIC 8/21/01 10.00 .01-APPLCTN FEE -PLUMBING 7/23/01 10.00 01-FIRE IMPACT - NONRES- 6/27/01 1747.98 INSPECT -NEW CONST 46/27/01 4076.42 ,01-FIRE 01-PLAN ALTERATIONS .5/31/02' 35.00 01-POLICE IMPACT - NONRES 6/27/01 11146.52 OWNER INS] i REQUEST FOR FINAL INSPECTION CERTIFICATE OF OCCUPANCY/COMPLETION i ""INTERIOR/EXTERIOR REMODEL TO A BUILDING**** DATE l0 PERMIT # ADDRESS �OCJ� 0(-" CD ( — PROJECT CONTRACTOR (\Ker�on 4-- The Building Division has received a request for a final inspection and a Certificate of Occupancy for the above referenced address. We would appreciate a final inspection of the site by your department. Approval by your department would result in a granting a C.O. for the address. If you have any issues that the contractor will need to address, please submit a statement for denial of C.O. or a conditional agreement to be attached to the C.O. Thank you for Engin<e'*erin1 s r-,>' /07 / 0-2— Public Works Zoninq Utilities_ Licensing Conditions: (to be completed only if approval is conditional)�l - G Certificate Of Occupancy Addendum Owner: Wal-Mart Address: 3653 Orlando Drive Date: June 7, 2002 Reason for Disapproval: ❑ Install the signal Loop at the entrance and Hwy 17&92 ❑, Install the required Stop sign and Right Turn Only sign at the exit from Wendy's. ❑ Replace the chain link fence along the west property line of the retention pond located in the southwest corner of the property (behind Office Depot). Applicant shall call Engineering Department (330-5652) for re -inspection. Thanks, Dave FASHA_ENG\Development Review\06-Post Approval\Certificate of Occupancy\Wal-Mart.CO June 10, 2002 a INSPECTOR REQUEST FOR FINAL INSPECTION CERTIFICATE OF OCCUPANCY/COMPLETION ****INTERIOR/EXTERIOR REMODEL TO A BUILDING**** DATE O� PERMIT # d�� Cj�L"� n I ADDRESS PROJECT G&A �T CONTRACTOR �� f1�an 4— L-0-W The Building Division has received a request for a final inspection and a Certificate of Occupancy for the above referenced address. We would appreciate a final inspection of the site by your department. Approval by your department would result in a granting a C.O. for the address. If you have any issues that the contractor will need to address, please submit a statement for denial of C.O. or a conditional agreement to be attached to the C.O. Thank you for your cooperation. Engineering Fire opvS Public Works l �/--o5 02 Zoninq Utilities Licensing Conditions: (to be completed only if approval is conditional) CITY OF SANFORD. FL UTILITIES DEPARTMENT REQUEST FOR FINAL REINSPECT ION DATE ADDRESS CONTRACTOR. rin THE BUILDING DEPARTMENT HAS PREPARED A C.OF 0. FOR THE ABOVE LOCATION AND THr-fNJTIAL INSPECTION WAS 1 DENIED DOE TO. UTILITY FE'A,---- L ITEMS. THE CONTRACTOR IS RE LQUESTINC- A REINSPECTIO.N OF RELATED ITEMS AND IS NOV.! ,,S FOLLOWS. . Gas G.- INSPECTOR OWNER:I.r�l� ADDRESS: �G S r'�,� ���%� l�•� DATE:-. 616 /©Z REASON FOR DISAPPROVAL:' epl+ Q S 1 ✓. A 1 er- Ct 55e- -� 6A Ic r" (s f f lq-5', CA Yk fete PFe /' us- )&I i 4-(a 1/4 4,e,s4by wq a S 4el, 1Cet/ ed zo 23s3 on Lc s i,% e -� # 1 /oposs -{v!x ctlained ;,I cto ed Ip05410'11, ®rope-r-.5lopc ✓h Q S�tr N--v� c ►/' a m S cr /'iff w T r c.4, 0-' &P 314 L S o d e fc ki FJO Va ivc on Pa side o-� bac-ICE' �w c%v�c -{� G�aih� oI1�► ✓cos;-�io,� 4r- owner (h).s /ock Ma'5+-ee- LaGl(- l<e!-i ar- 235.3 U5Cj onkt 6 y 04, pei�"SOnne I Yl l . (� FIRE DEPARTMENT UTILITIES PUBLIC WORKS ENGINEERING INSPECTOR d I I I I I I 1 I I I �• h— I I I I I REQUEST FOR FINAL INSPECTION \ CERTIFICATE OF OCCUPANCY/COMPLETION:;; 1 1 � ****INTERIOR/EXTERIOR REMODEL TO A BUILDIN-'*k-� r 1 1 ( c-> I 1 I DATE 1 � PERMIT # — .�� L'j I.. .. -- �... w...� L; E,. ADDRESS PROJECT �-1 �'''��.,��' � aE m a c) c u a� 0v CONTRACTOR (\�il 4� L�.�� C. a Cr cy- The Building Division has received a request for a final inspection and a Certificate of Occupancy for the above referenced address. We would appreciate a final inspection of the site by your department. Approval by your department would result in a granting a C.O. for the address. If you have any issues that the contractor will need to address, please submit a statement for denial of C.O. or a conditional agreement to be attached to the C.O. Thank you for your cooperation. Engineering Fire Public Works Zonin Utilities Licensing Conditions: (to be completed only if approval is conditional) I I 4u ram;.. INSPECTOR I i I I I I I I I REQUEST.FOR FINAL INSPECTION CERTIFICATE OF OCCUPANCY/COMPLETIONC'n I , I I I ****INTERIOR/EXTERIOR REMODEL TO A BUILDING7_" * f I I t. - II __ DATE lD PERMIT # ADDRESS c> c� C: PROJECT C`..I ►'-' �, CONTRACTOR01. The Building Division has received a request for a final inspection and a � 'M C. J Certificate of Occupancy for the above referenced address. We would appreciate a final inspection of the site by your, department. Approval by your department would result in a granting a C.O. for the address. If you have any issues that the contractor will need to address, please submit a statement for denial of C.O. or a conditional agreement to be attached to the C.O. Thank you for your cooperation. Engineering Fire Public Works Zonin Utilities Licensin Conditions: Ito e completed only if approval is conditional) 6/a. B GG b C_-)0 tow n L,3 / le ✓L¢ S G 07C a,7 o rr 64 VAJ1 i in T 710 n U v-e- GU r V71 O S !1 e- o ' � c (n �t � Per -%r,re-(� s on ZACk n OSc ��T c n � ,fie, � M /{-S LO e k- � .' 4v�� E2 S 11!e`? Z153 U s n p d G (a �_�C G �t l.¢.r o Y REQUEST f:OR FINAL INSPECTION CERTIFICATE OF OCCUPANCY/COMPLETION ****INTERIOR/EXTERIOR REMODEL TO A Rlin DIN( DATE d� PERMIT # ADDRESSS(O';3y( PROJECT CONTRACTOR The Building Division has received a request for a final inspection and a Certificate of Occupancy for the above referenced address. We would appreciate a final inspection of the site by your department. Approval by your department would result in a granting a C.O. for the address. If you have any issues that the contractor will need to address, please submit a statement for denial of C.O. or a conditional agreement to be attached to the C.O. Thank you for your cooperation. ` Engineering Fire Public Works Zoninq Utilities Licensing Conditions: (to be completed only if approval is conditional) INSPECTOR i REQUEST FOR FINAL INSPECTION CERTIFICATE OF OCCUPANCY/COMPLETION ****INTERIOR/EXTERIOR REMODEL TO A BUILDING`*** E DATE PERMIT ADDRESS yC-( rbt- PROJECT wCti1►'`NOX CONTRACTOR The Building Division has received a request for a final inspection and a Certificate of Occupancy for the above referenced address. We would appreciate a final inspection of the site by your department. Approval by your department would result in a granting a C.O. for the address. If you have any issues that the contractor will need to address, please submit a statement for denial of C.O. or a conditional agreement to be attached to the C.O. Thank you for your cooperation. Engineering Fire Public Utilities Conditions: (to be completed only if approval is conditional) 3 2- 2- Ll Ll 4IR DESCRIPTION DOOR OPERATOR 2 Q DOOR OPERATOR 4 Q INSECT CONTROL MON 6 0 SPARE 0 8 MOTORIZED CART 10 0 MOTORIZED CART 12 OTHER INCOME REC 1 14 OTHER INCOME REC 18 1 OTHER INCOME REC 18 I OThfR EINCOME REC 20 I OTHER IMCow REC 2-2 OTTER INCOiME REC 24 Q ' OTHER INCOME REC 26 SUPPLY FAN (2) 28 SUPPLY FAN 2 30 SUPPLY FAN (2) 32 SUPPLY FAN (2) 34 VESTIBULE RECEPT 36 LOSS PREY. RECEPTS 38 LOSS PREY. RECEPTS 40 LOSS PREY. RECEPTS 42 OUTSIDE RECET'T 44 COUNTING RM RECEPTS 46 CASH OFFICE RECEPTS 48 COURTESY DESK REC 50 HAS DRYER 52 HAND DRYER 54 WATER COOLER 56 IG RECEPTACLE 58 AUTO FLUSH 60 PORTRAIT STLD10 62 PORTRAIT STUDIO 64 PORTRAIT STLgI0 3 66 PORTRAIT STUDIO (3) 68 ICE MAKER 70 ICE MAKER 72 74 76 ICE MAKER 78 ICE Id. KER 80 SPARE 82 SPARE 84 SER.i�ES:—BANK= -- L OCA 7 I.:ON:-BA4......: DESCRIPTION I.C. RE EPTAC[E' 3 -'`--RECEPTACLES 5 RECEPTACLES 7 RECEPTACLES 9 11 SPARE 13 SPARE SPACE do PROV ISI p 15 SPACE & PROVISIONS 17 SPACE & PROVISIONS 19 SPACE A PROVISIONS 21 SPACE A PROVISIONS 23 SPACE k PROVISIONS 25 SPACE & PROVISIONS 27 SPACE & PROVISIONS 29 SPACE do PROVISIONS TOTAL TOTAL LOAD PER NEC ARTICLE 220 FEEDER LOAD PANELBOARD FURNISHED 8Y OWNER 0.00 0.00 3.36 2.00 28.00 16.67 7.36 1CVA 7.36 KVA 91 00 �0.00 2.00 KVA 76.67 AMPS 20.43 AMPS 20,43 AWS m r+ 0 'D z A m r` 20 208V, 3W 4w M Z 100A M.L.O. 10,000 AIC GROUND BAR ISOLATED GROUND 13AR FLUSH MOUNT � INSCRIPTION RECEPTACLES RECEPTACLES ECEIPTACLES RECEPTACLES o , SPARE SPARE SPACE dt PROVISIONS 1 m , SPACE d PROVISIONS 1 SPACE PROVISIONS 1 SPACE do PROVISIONS 2, SPACE Ir PROVISId��SPACE PROVISISPACE & PROVISISPACE do PROVISISPACE PROVISI 0 �iN I o D 0o LFS PANELBOARD 208/12OV, 3 PH, 4W 225A, M. L 0. Z m SERVES: RADIO GRILL PANELS & EQUIP. 10,000 AIC -mi LOCATION. RADIO GRILL GROUND 13US Z PANEL FURNISHED BY EDC MFR., INSTALLED BY E.C. ISOLATED GROUND BUS °° KVA FLUSH MOUNT n DESCRIPTION WIRE BRKR A B C BRKR WIRE E C IM 1 RADIO GRILL PANEL W 1 2 2.60 20 2 SPARE 2.64 3 208 t20 3 60 3 3 3.34 1..14 SB 3 DOOR. FREEZER o 5 20 2 7 1.14 11.0 A. 120 208 1 9 SPARE 60 3 20 1 0.88 EF—SB1 1 11 20 1 0.30 EH—SB1 CONTROLS 1 13 RADIO GRILL PANEL C 1 5.20 0.30 I 20 1 EH—SB1 LIGHTS 1 1 2.10 1 0.72 PADDLE FANS J 15 208 120 3 #6 60 3 20 1 3 3.22 0.50 MENU BOARD o . 7 20 1 1 19 SPACE ONLY 0.90 20 1 INSECT CONTROL 1.08 IS849 COTTON CANDY 21 SPACE ONLY 20 1 23 SHUNT TRIP BREAKER 3 XXXX 20 1 SPARE 25 RADIO GRILL PANEL "B" 1 8.07 20 1 SPARE 27 208 120 3 #3 10014 7.21 1 20 1 SPARE 2 9.16 20 1 SPARE TOTAL 18.21 14.62 17.65 KVA PER NEC ARTICLE 220 152 122 147 AMPS TOTAL LOADI 50.48 KVA 140 AMPS FEEDER LOAD 34.16 KVA _ 95 AMPS N 3 9 � 6 ' v I � 5 i 3 I ELECTRICAL EQUIPMENT SCHEDULE' MFG, MODEL NO. VOLT H LOAD TERMINATION NOTES MTG ICEE FC9 1120 2O8 1 22.5 A PRE —WIRED TO RADIO GRILL PANEL "A" IF GAD MEDAL #2214 WM 120 .1 - 20.0 A PRE —WIRED TO RADIO GRILL PANEL "A" - --- •••••.-.. +n r.•nrn ^"rI nAAICI 40A,w $ 27 18 16.803 ! 1 1 12. i LIES R7. 1 2 I >r _ ' — SB I ANEL )� ` - I16.607 _ 16.483 CT .t t6.806 16.664' t _ j 22 (PART. 2/2) 3 �20f,24A p�N ' ,� L_ �� 5 54" 15; I SB49 ' (D' RADIO GRILL 16.803 `` ` ' T ! 77 INSECT PANEL "A" , f ' CONTROL, 16.803 RADIO GRILL +96 "' , PANEL "C?`,,. 1 .f L--- I f�•ii�'�i� '�•� I -_ 3iJ J.��-"f"f �•-•;ti,%li i��.% �.. i � I r .. I ��,i} Ili (�'( ii .--•�' 71f---•-�,� i -_.;ram •wl ice, }: \ �, `✓L�j`.i' S Ji S( s 'i� +--.1 �:� Il_ Jl ^•�-"'jr'-_ l�"_s�-•., T !"" r • �\� \�--_J.l J'-��- "� •��.,.�]'v S`.-mil- I1"J CLOCK OUTLET +6'-4''FOR INSET f C_ ONTROL, 120V�TYP. OF 4 RAD10 'GRILL POWER PLAN cn co 00 A m 0 z cn cn I A 3 I ice........_.. ... - TOTAL LOAD 152 FEEDER LOAD 344.It RADIO GP1�L E�ECTR�G N0. DESCRIPTION A� EQUIPM T RREDULE SB1 ICES MACHINE MFG. S132 POPCORN MACNtNE tCEE MODEL N0. VOLT } GOLD MEDAL FC120 208 3 CASH REGISTER B SH14 y� S134 HOT DOG GRILL NCR 120 1 S135 NOT DOG BUN WARMER #2i 13 NACHO CHIP WARMER SRS CONVECTION COOKIE OVEN SB9 COFFEI'llE DISPENSER (SINGE, S810 ICE DSPENSER REWEEA i8OKETTLE 5813 ICE M EKA R 5B17 Foot) WARMER SB18 SAND Mcii REFRIGERATOR S820 UNDERCOUNTER FREEZER SB35 ELECTRIC WARMER SI339 .TOASTER S840 CAPPUCCINO MACHINE GOLD MEDAL 12( GOLD MEDAL 023 16 12C GOLD MEDAL 120 'OTIS SPUNKMEYER S-1 1 120 BUNN-SYSTEM 1 SINGLE: B 120 BUNK-OMATIC iD4T 1200 A WY07't R�1V 120 REMCOR Ti-SOS-BC 120 SCOTSMAN CNE806AS-32D 120 ANA CRC 118T2 208 / AMER. PERK. WARE 90 UL 201- TRUE TSSU-48--12 120/1 TRUE .�C-27F 120 1 BUNN-OMATIC RW1 S 720/1 STAR MFG. ST 02 120/1 CECILWARE G132-LD 120/1 GOLD MEDAL 3017 120/1 TRUF _ 120/1 i g. b1 17.65 KVA 122 KVA 147 AMF KVA 140 AMF Q7 95 AMP H Z m 0 z r LOAD Z� TERMINATION h 22.5 A 20.0 A PRE -WIRED RADIO GRI, I A PRE-YYlREp TO RAD10 GRt! _ 8'3 A PRE -WIRED TO RADIO GRt1 P -3 2.5 A , PRE- WIRIrD TO RADIO GR11 00 0.3 A PRE -WIRED TO ' 11.3 q PRE —WIRED TO RADIO GRILI rn 17.92 A _ w GRILL °' PRE —WIRED 15.0 A TO RADIO GRILL PRE —WIRED TO RADIO GRILL 4.2 A 13.6 A PRE—WIREO TO RADIO GILL 17.5 A PR — W1 Ep 0 RADIO PRE --WIRED 8.65 A TO RADIO PRE-111RED TO RADIO GRILL '` 6.3 A 9.0 A PRE —WIRED TO R GRILL o ; ADrO GRIIt ,,, 7.2 A ARE —WIRED TO RADIO GRILL ; 1 2'5 A PRE— WIRED TO RADIO GRILLI PRE —WIRED 7.5 A TO RADIO PRE—WrREO GRILL F v RADIO GRILL 15.0 q 9.0 A F PRE --WIRED TO RA010 GILL p OUTLET: NEMA: 5— , 20R. 52.0 A PRE—W1RE0 TOR e RADIO GRILL, — PI A 25.0 q PRE —WIRED TO RAnln �o... r-. I z CI'TX OF rSANFO" PY,"HT APPLICATION P• rmit No.: OZ _� (XO Q�-- Date: - z .. -,1 _. _ ...... . Job Address- Permit Type: _�I3c,ildiag ✓ Electrical Mechanical —_ plumbing Fire Alerm/SprinkJer Description tlon 'of Work: V Additiortal Information for Electrical & Plumbing Permits Electrical: 4ZAddition/Alteration __Change of ServiceTemporary Pole _� New AMP Ser..",M (P of AMPS —_ } PlumbiagjResidenlial: Addition/Alteration — New Construction (One Closet Plus Additional) Plumbing/Commercial: Number of Fixtwv--,` Number of Water & Sewer Drainage Lines Number of Gas Lutes Occupancy Type: _Residential !Commercial _- Industrial 'Total Sq Ftg: value of Work Zt-, , _ �� 'Type of Construction:�--1�-'�—- Flood Zones Number of Stories:_ / Number of b-A•rt2ing Units Parcel No.: _ T D -- , �t� ^ 3bD,^03S p —G) d,�y (Attach. Proofof Ownership & Legnl Description) ' Owner/Addres-/Phone:-1�Cir�� L-0 Sri �o Z7 — &Vj?77 Contractor/Address/Phone:1 Contact Person: Title Holder (if other than Owt►er): Address: Bonding Company: Address: Mortgage Lender: Address: Architect/Enginea Addrew l� ANT �`lr 7yz Lod D t/ 2a�—�_ State License Nutrbf :. A_2� Z.7 Phone & Fax Number: 911Z *2,L Z .S`b Q f' t� .• --- — - 0 Phone No-: Fax, No.: Appliestion is hereby made to obWn a permit to do the work and installatio u as indicated, I certify thst no work or installation has commenoed prior to the issuance of A permit and that all work will be, performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit mast be secured for ELECTRICAL WORK., PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEAT ER.S, TANKS, and AIR CONDITIONERS, eta OWNER'S AFFIDAVIT; I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCIN9, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORD MN YOUR NOTICE OF CONDaNCEME. IT. It NO i ICE: In addition to the requirements of this perinit, there may be additional restrictions applicable to this property that may be found in the public reoores of this county; and here may be additional permits requirtad from other governmental entities such as water management districts, state agancics, or federal agencies. Acceptaride of permit is verification that I will notify the owner oftfi=propaV of the requirements of F)orida Lien Law, FS',13, -- - Sign a of Owner/Agent bate Signature of Contractor/Agent Date Print tuner/Agent's Name Print Contractor/Agent's Name --LgAP, Sipnetyra MarTJv' State ��fg���,�,� ao1F.Pr F7/eGn I{AREN DRING llat Sill _.Ao �Rtary-SIB, 1'� C"Qjoljd G - Date MY COMMISSION # CC 825838 MY COMMiSS10N # CC 825833 EXPIRE5:05121/2003 w� Q �ypiRE5:05/21/2003 �OFF�o �OFfv� 1.80C 3-NOTARY Fla, Notary Service & Bonding Co. 1.800-3-NOTARY Fier. Notary Service & Bonding Co. 'J Owna/Agent is _ Personally Knowtl to Me or ProducedlD APPLICATION APPROVED 6Y: _ ig�1_ Special Conditions: Contractor/Agent is v Personally Known to tide or Produced ID LY-50 R MOUNT DEVICES WITHIN CABINET WORK AT 8"AFF. ROUTE ALL CONDUIT CONCEALED AT BASE OF CABINET. COORDINATE CASH l%. rig t o,rr- . _ _ L[P-4,6 SIDE C cn NIPPLES r+ 03 16•610 PROVIDE BOX (y Z t60"(UN1 16.904 FURNISli Z PVC CONOi ABOVE CONDUIT CAVITY. H z 16 • 951 EXISTING p . BE RFLOC EXISTING CONTROL AS SHOWr COMPACTOR, o CIRCUITRY GENERAL C m WAL—MART m DEPARTMENT OF THE TRH VAL INE SCN MS. KIM TOL 16.952 BALER WILL y RELOCATE THE`` SWITCH AND F o THE GENERALN THE WAL-MAR T -- DEPARTMENT y_ OF THE BAL, v SCHENKEL AT 47 TOLLER AT (5C 16,953 FURNISH AND WEATHERPROOF SWITCH 80X OU- AND A 120 V( O #1065-N5 IN STD 16.972 FURNISH AND IN BOX AT r Permit No.: / Job Address: Permit Type, Dow: 16 Dl- J�rw-QJ -r/. .Additio, aal Information for Mctcieal & Plumbing Permita Electrical: ­AdditioW.Alteration Change of Service Temporary Pole —New AMP Service !# of ANIFS 1. PlumbingfResidential: _addatiotl/Alterat:on New Construction (One (,loset Flux ,._ ,,._...•... Additional) PhimhingJCnmrnerciai: Numher of Fixi Tres NUM) r of Water & Sewer Drainage Lin" Number of ("m f inre Oeenpancy Type: _Residential Commercial -L dustrtal Total Sq Ftg: : Value of Woriil Type of Construction: Flood zouc: iYumber. of stories: Number of Dwclliug Units. Pamel No.: (AUxcit Proia of Owrtership & Legal Description) Uwaer/AddresslYhoneti I gin„ ti Coatractor/Address. Ltcenae Maribor: =taa Ferson: Ph000 &' r-" Number; q(/Z-_Il9_L1 07ol- L)If%7 Title Holder (Uother than Owner); Address: Bondins Company: Address: Mortgage Lender: Address:.- Archhect/Enginew Phone No.: Address- 1{ax No.: Application is hereby made to o;xain a permit to do the work and installations as indicated. I. certify thzt nowork or installation has rnmmtncFrl lwior tn.the. i"miArne. of A perm it'And that Alt work, wtl.l be. perfome+d to meet standards of all laws regulating constn:etion ui this juriWXI,1ivtt. I ut1dcrtlat1d polio a suparNlc partr:it rrtttsl be sccumd for ELEMUCAL WORK, FLUM$TNO, $IONS, WFLU, FOOTS. FURNACES, EOiLERS, HEATERS. TANKS, and AIR CONDITIONERS. etc. OWNER'S AFFPAYIT: 1 eertify that all of the lbregoing information is actuate and that all work will be done in compliance with Of af,pl;cable laws regulating construction and zPmr..g. WARN1NG`TO OWNER: YOUR 1'A1LLME TO RECORD A NOTICE or CONWENCEMENT MAY RESULT tN YOUR PAYINO TWICE 1 OR IMYKUVEMIEN'l S TO YUUK FX0ftlt'I'Y, [F YUI_i INTEND TO ORTAI11 FINANC114—, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING Y'JaR . NOTICE OF£OMMENCEMEItiT. +1 NOTICE: Li additim to the requiruneats of this peitii!. , (teat cnq tx additivr►al ros:rit titn:s applicably to this prope ,y %hat may tm found in the public records of this county. and fare may be additional perorate required fi-mn ether $nvemmental enhiift vX4 ac water rr anagement dimiots, stato agmcim, or fvdcral agencies. Acceptauce of permit it verification that ; Will notify the owner of ale property of the requirements of Florida Lien Law, FS 711. Signature of Owner/Agent rP Print 0%na/Agent's Name Signature of Notary -State of Florida Date �7 S -- — Susan C. pensieri VA my-cowpIg 61,%,V.P�ES! ct�obber,, 31, 2t102 Owrer/Agot iv Pere-onally Known to Me or (�.DY pr��C4Ct l9 � rq'SOtLaf�ov�T[ tpD$ �I" c�ROYFAIN INSURANCE, INC Produced ID �uood 10 _ APPT.TrATIAN APA1 OWD AY DAte: - Special Canditions: SANFORD FIRE,DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl.- -2771 ; P. O. Box 1788, Sanford, Fl. 32772 (407 302-2520 .I FAX (407) 330-5677 Pager (407) 918-0395 Plans Review Sheet Date: March 21, 2002 Business Address: 3653 Orlando Drive Occ. Ch. #36 New Mercantile - Business Name: Wal-Mart Ph. (407) 481=0872 Fire Equipment: Orlando Fire Equipment Co. Ph. (407) 481-0872 Fax (407) 839-3994 Reviewed [ ] Reveed wlthCUltlment�� ] Rejected u_. Reviewed by: Timothy Robles, Fire Protectiori Inspector Comment: Plans,reviewed as mercantile. (F:F.P;C. Chp. #36) Fire equipment plans to be submitted for review, permitting, and inspections. 1.1 Application — New UL Fire Suppression System • Fire Department requires fire protection system to be tied into the main fire alarm upon activation "K" rated fire extinguisher required per N.F.PA. #10 (1998) ed • Final inspection required for "Dump Test" > Appliance verification • PLANS REVIEWED CITY OF SANFORD SANFORD BUILDING DEPT THESE PLANS ARE REVIEWED AND CONDITIONALLY ACCEPTED FOR PERMIT. A PERMIT ISSUED SHALL BE CONSTRUED TO BE A LICENSE TO PROCEED WITH THE WORK AND NOT AS AUTHORITY TO VIOLATE, CANCEL, ALTER, OR SET ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL_ CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT" THE BUILDING DEPT FROM THEREAFTER REQUIRING A CORREC- TION OF ERRORS ON THE PLANS, CONSTRUCTION OR OTHER VIOLATIONS OF THE CODES. 2-3.2* Fire extinguishers provided for the protection of cooking appliances that use combustible cooking media (vegetable or animal oils and fats) shall be listed and labeled for Class K fires. Exception: Extinguishers installed specifically, for these hazards prior to June 30, 1998. HECEIVED MAR 1 $ 200r� ` Copyright NFPA *110 1°19$ r-A. ACMdam � ©u m ®® ALTAMONTE SPRINGS OFFICE 801 W. State Road 436 SUITE #2183 ALTAMONTE SPRINGS, FL 32714 Phone (800) 948-7124 or (407) 682-0317 Fax (407) 772-0623 Email Address: REG66@captiveair.com TO: WHOM IT MAY CONCERN DATE: MARCH 14, 2001 FROM: SCOTT TOWNER i RE: CAPTIVE AIRE PRINTS NO OF PAGES INCLUDING THIS COVER: 1 WE HEREBY GIVE ORLANDO FIRE EQUIPMENT CO. PERMISSION TO USE CAPTIVE AIRE SYSTEMS; INC. SUBMITTAL PRINTS WHEN APPLYING FOR PERMITS ON JOBS THEY ARE CONTRACTED TO DO WHILE INSTALLING FIRE SUPPRESSION SYSTEMS IN YOUR COUNTY I TRUST THAT THIS WILL COMPLY WITH YOUR REQUIREMENTS. PLEASE CALL IF YOU HAVE ANY QUESTIONS. Certificate of Insurance This certificate is issued as a matter of information only and confers no,rghts upon you the certificate holder. This certificate is not an insurance policy and does not amend, extend. or alter the coverage afforded by the policies listed below. Named Insured(s): Staff Leasing Inc. d/b/a Gevity HR and its wholly owned subsidiaries including Gevity HR, LP; Gevity HR IV, LP; Gevity HR IX, LP; and Gevity HR X, LP 600 301 Boulevard West, Suite 202 Bradenton, Florida 34205 Coverages: INSURANCE IN TOUCH WITH BUSINESS Insurer Affording Coverage Continental Casualty Company The policy(tes) of insurance listed below have been Issued to the insured named above for the policy period indicated. The insurance afforded by the pol)cy(ies) described . herein is subject to all the terms, exclusions and conditions of such policy(ies). . Date Type of Insurance o Extended �us Policy Number Limits * 0 Policy Term Workers 1-1-2003 WC 189165165 Employers LtabUity Compensation Other. WC 189165182 Bodily Injury by Accident WC 247848874 $1,000,000 Each Accident WC 2478410M Bodily Injury by Disease $1,000,000 Policy Limit Bodily Injury by Disease $1,000,000 Each Person Employees Leased to. Effective Date: 1/1/02 10956 Orlando Fire Equipment Company ; FL 3 H 065351 The above referenced workers compensation policy(les) provide(s) statutory beneftis only to the employees of the Named Insured(s) on such policy(les), not to the employees of any other employer. *If the certificate expiration date is continuous or extended term, you will be notified if coverage is terminated or reduced before the certificate expiration date. However, you will not be notified annually of the continuation of coverage. Notice of Cancellation: (Not applicable unless a number of days are entered below) Before the stated expiration date, the company will not cancel or reduce the insurance afforded under the above policy(ies) until at least 10 days notice of such cancellation has been mailed to: Certificate Holder: I City of Sanford Trudy WMIarnis PO BOX 1788 Authorized Representative Sanford, FL 32772-1788 St. Louis, MO (877) 427-5567 12/15/01 Office Phone Date Issued SANFORD FIREDEPARTMENT , FIRE PREVENT 101Y DIVISION 300 N. Park -Ave., Sanford, Fl: 32771 / P. O. Box 1788, Sanford, Fl. 32772 (407 302-2520 I FAX (407) 330-5677 Pager (407) 918-0395 Plans Review Sheet Date: March 21, 2002 Business Address: 3653 Orlando Drive Occ. Ch.#36 New Mercantile - Business Name: Wal-Mart Ph. (407) 481=0872 Fire Equipment: Orlando Fire Equipment Co. Ph. (407) 481-0872 Fax (407) 839-3994 Reviewed [ ] Re i ed�,'w"ONlthrComein i ] Rejected Reviewed by: Timothy Robles, Fire Protection Inspector Comment: Plans reviewed as mercantile (F.F.P.C. Chp. #36) Fire equipment plans to be submitted for review, permitting, and inspections. 1.1 Application — New UL Fire Suppression System • Fire Department requires fire protection system to be tied into the main fire alarm upon activation • "K" rated fire extinguisher required per N.F.PA. #10 (1998) ed • Final inspection required for "Dump Test" > Appliance verification 1 ORLANDO FIRE EQUIPMENT COMPANY 3220 37`h STREET ORLANDO, FLOR1DA 32839 r (407) 481-0872 FAX (407) 839-3994 AUTHORIZED SIGNATURE FORM Qualifiers Name: Certification Number (s) Company Name: City, State, Zip: Phone: I hereby authorize the and Building Departm company to: Edmund J. Aleksa 54645800012001 Orlando Fire Equipment Co., Inc. Orlando, Florida 32839 407-481-0872 Sao _4anning, Zoning mits_for_the above referenced Location Address: Wa -too o I certify that the above person is authorized by the company and I understand that I am fully responsible and liable for all acts performed under said permits. Sig ure ualifier Signature of thorized ent Sworn to and subscribed before me this day of 20 J"- , My commission expires NiAy'. ", Susan C Spensieri *; .* MY COMMISSION # CC755682 EXPIRES 3 October 31, 2002 ;'k BONDED THRU TROY FAIN INSURANCE, INC. CITY OF SANFORD FIRE DEPARTMENT FEES FOR SERVICES 2 PHONE # 407-302-1091 * FAX #: 407-330-556677 DATE: J a ock PERMIT #: BUSINESS NAME / PROJECT: ADDRESS: 0 s- l P, PHONE NO.: / R1— C)�?o2 FAX NO.: L%r�� �c��— 32I CONST. INSP. [ ] C / 0 INSP.:[ ] REINSPECTION [ ] PLANS REVIEW F. A. [ ] F.S. [ ] HOOD [ ] PAINT BOOTH [ ] BURN PERMIT [ ] TENT PERMIT LZANK PERMIT [ ] OTHER [\X TOTAL FEES: $ C� ^ ©6:) (PER UNIT SEE BELOW) COMMENTS: Address / Bldg. # / Unit # Square Footage Fees per Bldg. / Unit 1. 2. 3. 4. 5. 6. 7. 8. 90 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. Fees must be paid to Sanford Building Department, 300 N. Park Ave., Sanford, FI. 32771 Phone # -407- 330-5656. Proof of Payment must be made to Fire Prevention division before any further services can take place. I certify that the above is true and correct and that 1 will comply with all applicable codes and ordinances of the City of Sanford, Florida. Sanford Fire Pre ntion Division pplicant'. Signature E i i i WAL*MART STORES, INC. WAL*MART SIGN SHOP LYNN BEAVER 2001 S.E. 10th BENTONVILLE, AR. 72716-0550 (479)277-9516 PHONE (479)204-0005 FAX February 7, 2002 ADDRESS 3653 Orlando Drive Re: Store #857 Sanford; FL. To Whom It May Concern; I hereby authorize Florida Signs Unlimited and its representatives to act as agent on our behalf for sign permits and any variance at the below address: WAL-MART #857 3653 Orlando Drive Sanford, FL. 32771 Sincerely, Property Owner Property Owner Name: WAL-MART Stores East, LP Property Owner Address: 702 Southwest 81 Street Bentonville, AR. 72712 Property Owner Phone: (501)273-4000 State of: Arkansas County of: Benton Subscribed and t rn o Notary Public My Commission Expires day of 20 Q JUN. -IT OO ME) 18:45 - P. 005/005 Prepared by and return to: WILLIAM L. COLBERT, ESQUIRE P. O. Box 4W Sanford, FL 32772480 PARCEL ID NUMBER 11-20-30-300-0410-M r�paj—" L THIS WARRANTY DEED made the day of June, A. D_ 2000, by ROBERT J. SMITH and BETTYE D. SMITH, his wife, hereinafter called the Grantor, to WAL-MART STORES EAST, INC.. whose address is --- hereinafter called the Grantee. WITNESSETH: That the Grantor, for and in consideration of the sum of $10.00, and other valuable considerations, receipt whereof is hereby acknowledged, hereby giant, bargain, sell, alien, remise, release, convey, and confirm unto the Grantee all that certain land situate in Seminole County. Florida, viz: Begin 483.38 feet South of the Fast 114 of Section 11. Township 20 South, Range 30 East, run thence North 71 °3319" West 344.69 feet thence South 25°47'00" Wag 225.46 feet thence South 71°33-59" East to a point South of beginning thence North to point of beginning, Seminole Courity. Florida. TOGETHER with all the tenements, hersditaments, and appurtenances thereto belonging or in anywise appertaining. TO HAVE AND TO HOLD, the same in fee simple forever. AND the Grantor hereby covenants with said Grantee 00 the Grantor is lawfully seized of said land In fee simple: that the [grantor has good right and lawful authority to sell and convey said land, and hereby warrants the title to said land and will defend the same against the lawful claims of all persons whomsoever, and that said land is free of all encumbrances, except taxes accruing subsequent to December31, 1999. IN WITNESS WHEREOF, the said Grantors have signed and sealed these presents the day and year first above written. Signed, sealed and delivered in the presence of witnesses: Signature Printed Name Signature Printed Name STATE OF FLORIDA COUNTY OF SEMINOLE ROBERT J. SMITH BETTYE D. SMITH 103 County Place Sanford, FL 32771 I HEREBY CERTIFY that on this day, before me, an ofttcer duty authorized to administer oaths and take acknowledgments, personallyappeared ROBERT J. SMITH and BETTYE D. SMITH, his wife, (check one) ❑ who are personally known to me or O who provided their Florida driver's license as identification and who executed the foregoing instrument, who acknowledged before me that they executed same, and that an oath was not taken. WITNESS my hand and official seal in the County and State fast aforesaid this day of June, 20W. Print Name: Notary Public, State of Florida i:wAKfiLEs%*%REr&ra umwmVDE O-mw -7 } 7 x� 110A 29TH AVE. W BRADENTON, FL 34205 PH.(941) 747-1000 March 6, 2002 City of Sanford Building Department Attention: Ilene Fax 407-330-5679 Re: Walmart Signs requested. 7" set of Walmart letters 3' SuperCenter 30" Food Center 30" We Sell For Less 30" Low Prices Two readings of Always 18" Bakery 18" Deli 18" Meat 18" Produce 18" Pharmacy 18" 1-Hr. Photo 18" Optical 392.00 87.00 50.47 68.20 44.38 292.00 10.25 5.30 6.84 11.88 14.56 16.50 10.25 jY ov' S r-A' A Total square feet on wall is 1,009.63. The height of the front wall is 25' with the lenght being 490'. Please tell me if the above is okay and also we are changing the face on the front pole sign. Will I need a permit for that. If I need engineering drawings for the wall signs, please tell me and finally, do 1 need a application .per sign or can 1 group them together on one application. I will await your call. C�arles F. Ogle Partner D N SMCE 1951 ff 92 A ffid OCOA ffffi AP 11OA 29TH AVE. W. BRADENTON, FL. 34205 PH.(941) 747-1000 March 6, 2002 City of Sanford Building Department Attention: Ilene Fax 407-330-5679 Re: Walmart Signs requested. 7" set of Walmart letters 3' SuperCenter 30" Food Center 30" We Sell For Less 30" Low Prices Two readings of Always 18" Bakery 18" Deli 18" Meat 18" Produce 18" Pharmacy 18" 1-Hr. Photo 18" Optical 392.00 87.00 50.47 68.20 44.38 292.00 10.25 5.30 6.84 11.88 14.56 16.50 10.25 /Y I C-�c, 5 r'A''` 1 Total square feet on wall is 1,009.63. The height of the front wall is 25' with the lenght being 490'. Please tell me if the above is okay and also we are changing the face on the front pole sign. Will I need a permit for that. If I need engineering drawings for the wall signs, please tell me and finally, do 1 need a application - r sign or can I group them together on one application. I will await your call. C�arles F. Ogle Partner SINCE 1951 040MA RON MAMA", t ill March 20, 2002 City of Sanford Building Division 2nd. Floor 300 N. Park Ave. Sanford, Fl. 32771 Re: Walmart permits To whom it may concern, Enclosed is my application for signs for the above. If I need anything else, please call. Sincerel Charles F Ogle Partner 1101 29THAVE W. BRADENTON, FL 34205 PH.(941) 747-10001FAX(941)746-5689 VISIT OUR WEBS►TE AT FLORIDASIGN.COM m k� ^Y/ �� 1 QQ Date Permit # Pre -Construction A i- n Job Name Job Address C4�' Mobilization A. Job Office Trailer B. Site Access'- All Weather Stabilized Roadway 4r,""`°""`� 1 C. Security II. Site A. Fire Safety B. Building Access - �mergene Vehicle, etc. C. Material Storage D. Trash Receptacles E. Toilet Facilities F. Temporary Power/Water a� G. Environmental Protection III. Structures _ A. Building Identification" - A, dJ 5 s w a 10 C� . B. Horizontal AccessX b �P C. Vertical Access/ D. Safety E. Trash, Litter, Debris Control F. Changes and Revisions to Approved Plans IV. Inspections �e ; - Sews �� � A. Utilities -Utility Department s vco B. Site - Engineering Department - w c;,u,� °� �` Ckas� C. Structure Building Division C �A" D c p S3 %w ip" C o, i 1. Required Inspection(s) � - Cv L , -2— wer Bup i d g Occupancies 4. Permit Locations and Inspections Log 5. Inspection Request Procedure 6. City Staff Contacts (��¢ cSL�SS.�..L Pre -Construction Meeting Sign -In Sheet Date _7 --O 1. Permit # Job Name q, — r Job Address UL NA 0 Owner's Representative(s) Job S, r- j 1,Jgc4k ¢07­ 4�4-a3/1 — Building Contractor F, i' - i�'Y /y11DQ41-a,J, 770. 9�• �io�o -7-iJ • c.S 3• do ``1 Electrical Contractor -)VvNLCwl V—_ Rca _ �5�1 —<48,53 -000,S7 Mechanical Contractor Plumbing Contractor 6eO2s2 6o,,LD /Yl pNy,eCA 5r o,s/ 7 & 3, Fire Safety H 'pzr,6 '' Tveio >= 0 i ! Other S -/z O* Gt O`_ c, clQ7 7-��19 r 1"-RiZ_ A_,f,eK >> 3�e-;z y 13c�(.(.SouTK �Gc LORr�Z W .(40 7)- 3o0-76pG1 City Staff vn z7o7 9 r � L a,.,, I &Z, CPH i En knee- y' s Y'u 7 - 3Xz- 68 �{f L �o w� Pre-Construction Agenda Date CQ ,�"(� 1c� PikPermit 3 Job Name. lCti ! 4 I 1 �iC �G� n j(c) n Job Address 3�653 D dc) �'D iv 6 I. Mobilization A. Job Office Trailer B. Site Access — All WeatherStabilized Roadway' C. Security II. Site A. Fire Safety B. Building Access — Emergency Vehicle, etc. C. Material Storage D. Trash Receptacles E. Toilet Facilities F. Temporary Power/Water G. Environmental Protection II1. Structures A. Building Identification B. Horizontal Access C. Vertical Access D. Safety E. Trash, Litter, Debris Control F. Changes and Revisions to Approved Plans IV. Inspections A. Utilities — Utility Department B. Site — Engineering Department C. Structure — Building Division 1. Required Inspection(s) 2. Prepower -3. Building Occupancies 4. Permit Locations and Inspections Log 5. Inspection Request Procedure 6. City Staff Contacts BUILDING DIVISION OF COMMUNITY & ECONOMIC DEVELOPMENT DEPARTMENT CERTIFICATE OF OCCUPANCY (AKA: C.O.) A. Final inspection is requested by the contractor 1. A "Certificate of Occupancy Request for Final Inspection" form is completed and distributed to the following departments: fire, engineering, zoning; public works, and utilities. a. Each department checks for compliance. 1. If a department denies the C.O., department notifies contractor of reason and C.O. is placed on hold until compliance is met. 2. If department approves the C.O. with a conditional agreement, that department will be responsible to monitor completion of requirements. 3. If department approves the C.O., they sign off on the C.O. b. The contractor is advised if additional documents are needed to be submitted prior to the issuance of the Certificate of Occupancy. 1. If additional documents are required, C.O. is placed on hold until documents are received. 2. If additional documents are not needed, C.O. will be printed upon approval of final inspection by the inspector. . C. An inspection slip is given to the building inspector for` a final inspection. 1. If building inspector rejects the final inspection, rejection notice is left on job site listing problems. Rejection fee is required to'be paid prior to - re -inspection of the final. 2. If building inspector approves.the final inspection; approvals are entered into the computer system and the C:O. is printed. 13 All departments sign off on C.O. The Power Company is called,to release final power. C. The C.O. is issued to contractor. BUILDING DIVISION OF COMMUNITY & ECONOMIC DEVELOPMENT CERTIFICATE OF OCCUPANCY REQUEST FINAL INSPECTIONi2EQUESTED BY CONTRACTOR "CERTIFICATE OF CONTRACTOR IS INSPECTION 6 OCCUPANCY REQUEST REMINDED OF SCHEDULED FOR FOR FINAL ANY DOCUMENTS BUILDING INSPECTION" REQUIRED PRIOR INSPECTOR FORMS ARE TO ISSUANCE OF COMPLETED AND CERTIFICATE OF i FORWARDED TO: OCCUPANCY FIRE DEPT. FINAL FINAL . ENGINEERING BUILDING BUILDING PUBLIC WORKS CONTRACTOR INSPECTION INSPECTION UTILITIES SUBMITS IS FAILS & REQUIRED APPROVED ZONING DOCUMENTS REJECTION FEES ARE PAID, INDIVIDUAL FINAL DEPTS. NOTIFY STOP - INSPECTION IS CONTRACTOR OF C.O. HELD RESCHEDULED ANY REASON UNTIL EACH WHY C.O. MAY BE DEPT. DENIED APPROVES DEPTS. CONDITIONALLY APPROVE C.O. REQUEST. CONDITIONS TO BE MONITORED BY INDIVIDUAL DEPARTMENT FOR CO IS REIFASED, COMPLETION OF POWER CO\SPA-N'N', REQUIREMENTS IS NOTIFIED TO GIVE FINAL POWER DEPTS. APPROVE C.O. FIN AL- C.O. IS BUILDING PRINTED INSPECTION IS APPROVED CO IS ISSUED BUILDING DIVISION OF COMMUNITY & ECONOMIC DEVELOPMENT DEPARTMENT INSPECTION. PROCEDURES After a permit is issued, there are inspections that are required to be performed. The owner/contractor must call the inspection phone line 330-5659 prior to 4:00 P.M. in order to request an inspection for the following business day. The general contractor is required to call all sub -contractors inspections in. All rough -in inspections are to be performed at time of framing inspection. All finals are to be performed at -same time at completion. The information that is needed to request an inspection is: - I . Permit number 2. Owner/Contractor name 3. Owner/Contractor phone number 4. Address of requested inspection 5. Type of requested inspection 6. Date requested inspection needed BUILDING DIVISION OF IMMUNITY & ECONOMIC DEVELOPMENT INSPECTION REQUEST PROCESS . :,DING NET IS ;UED CERTAIN PHASE OF CONSTRUCTION IS COMPLETED AND NEEDS TO BE INSPECTED INSPECTOR RECEIVES ALL INSPECTIONS THAT ARE SCHEDULED. INSPECTOR SORTS THEM ACCORDING TO HIS/HER INSPECTION ROUTE - INSPECTOR PERFORMS INSPECTION(S) ON INSPECTION SLIP. INSPECTOR NOTES APPROVAL OR REJECTION ON THE PERMIT INSPECTION CARD THAT IS POSTED ON JOB SITE. ALSO NOTES IT ON INSPECTION SLIP. OWNER/GENERAL CONTRACTOR CALLS 330-5659 PRIOR TO 4:00 P.M.. TO REQUEST AN INSPECTION FOR THE FOLLOWING- BUSINESS DAY. INFORMATION NEEDED IS: PERMIT NUMBER, NAME, PHONE NUMBER, ADDRESS OF INSPECTION, TYPE OF INSPECTION, AND DATE INSPECTION NEEDED SECRETARY RETRIEVES REQUEST FROM INSPECTION LINE. AN INSPECTION SLIP IS COMPLETED FOR EACH INSPECTION ADDRESS INSPECTOR RETURNS THE INSPECTION SLIPS TO THE SECRETARY. THE SECRETARY ENTERS THE INSPECTION RESULTS INTO THE COMPUTER. IF INSPECTION WAS REJECTED, A $15.00 REINSPECTION FEE IS DUE PRIOR TO ANY MORE INSPECTIONS ON JOB SITE. s s s p9 i S h h FIRE DEPARTMENT / LIFE SAFETY REQUIREMENTS t PLANNING AND DEVELOPMENT The following are general, requirements to meet Fire Department / Life Safety requirements for construction and development. Each particular project may require additional requirements, which are reviewed on a case by case basis. Project Name: XXX Address: XXX Type Occupancy / Project: XXX HYDRANTS [ ] Residential areas / 1 & 2 family structure: every 800 feet within .400 feet of buildings shall supply minimum of 600 gpm at 20 psi residual [ ] Multifamily area / Apartments: every 500 feet within 250 feet of buildings shall supply minimum of 1250 gpm at 20 psi residual [ ] Commercial areas: every 500 feet within.250 feet of principal building shall supply minimum of 1250 gpm at 20 psi residual Additional: [ ] During construction, water supply must be available on site before construction. [ ] During construction, access must be provided with an all- weather roadway surface capable of supporting fire apparatus necessary to respond. Whenever possible, two means of access should be provided. [ ] Access roads shall be a minimum of 20' in width. [ J Minimum overhead clearance must be 13' 6" / Dead end access roads longer than 300' shall be provided with approved provisions for turning FD apparatus around with a minimum of a 90' diameter. [ J Turning radius must be minimum of 40' outside turning radius, plus no overhang obstructions for an additional 5' for aerial apparatus . AUTOMATIC FIRE SPRINKLER REQUIRED Commercial (Type construction based on SBCCI Tables) [ ] Type I Construction — 12,000 square feet or more / more than 2 stories and 10,000 square feet, more than 3 stories regardless of square feet [ ] Type II -Type VI Construction — 8,000 square feet or more / more than 1 story and 5,000 square feet / more than 3 stories regardless of square feet [ J Type l Construction — more than 4 stories in height [ ] Type If = Type IV Construction — more than 3 stories in height [ ] Type V — Type VI Construction — more than 2 stories in height (] Type I — Type VI Construction—,6,000 square feet or more (restaurants, bowling alleys. etc.) FIRE DEPARTMENT / LIFE SAFETY REQUIREMENTS 2 PLANNING AND DEVELOPMENT [ ] Type II — Type VI Construction — Public assembly (theatres, stages, etc.) no minimum square footage, if located above first floor [ ]. All buildings over 75 feet in height, regardless of construction or.square footage [ J All buildings over 20,000 square feet, regardless of construction [ ] Group H (Hazardous), regardless of square footage SPRINKLERS (Additional) [ ] More than 12 but less than 50 heads, shop drawings may be used [ ] Sealed letter from Engineer of Record, stating design criteria for system to be submitted with construction plans. (50 heads or more) [ ] Underground Fireline — if contractor other than sprinkler contractor installs, separate permits, plans and inspections required. Class 5 license required. [ ] Point of service refers to 5' out from building, not from main water supply [ ] Monitoring required [ ] Underground and aboveground systems inspections require Visual, hydrostatic, and flush tests. 24 to 48 hour notifications required for inspections FIRE ALARM SYSTEMS [ ] As per NFPA 72 [ ] Over $5000 for work requires engineer sealed plans EMERGENCY ACCESS FOR GATED COMMUNITIES [) Gates must be able to be activated by emergency personnel with manual back up in the event power failure. (SOS systems, Cards, Keypads, Knox Key, etc.) () Knox Box required for FD emergency access for all facilities having sprinkler systems, alarm systems, or any facility having restricted access. ADDITIONAL REQUIREMENTS () Burn Permits required for on -site burning for land clearing purposes, subject to City of Sanford and Dept. of Forestry regulations. Permit cost $100.00 PHONE CONTACT LIST Building Division Dan Florian - Building Official 407-330-5658 Joy Deen — Deputy Building Official 407-330-5643 Robert Bott — Plans Examiner 407-302-9417 Bill Oden — Code Compliance Inspector 407-330-5643 Contractual Position — Permit Technician 407-330-5656 Jo Ann Johnson — Permit Technician 407-330-5660 Mary Muse — Admin. Secretary 407-330-5657 Inspection Request Line 407-330-5659 Fax Machine 407-33'0-5677 Fire Department Mike McGibeny — Fire Marshal (Code Questions) 407-302-1091 Pete Tucker — Fire Inspector (Plans Review) 407-302-1022 Tim Robles — Fire Inspector (Fire Inspections) 407-302-2520 Utility Department Paul Moore — Utility Director 407-330-5640 Ed Woods (Field Inspector) 407-302-1025 John Chanoit (Field Inspector) 407-302-1025 Public Works Department Jerry, Herman — Public Works Director 407-330-5680 Kris Strine — Admin. Secretary (Driveway Inspections) 407-330-5681 Engineering Department Jay Marder — Planning & Development Director 407-330-5670 Bob Walter — City Engineer (Site Work inspections) 407-330-5671 Chris Smith — Engineering Asst. (Site Work Inspections) 407-330-5674 Russell Gibson — Land Dev. Manager (Issues Addresses) 407-330-5669 Miscellaneous Agencies Sunshine (Utilities Locate) BellSouth Telephone Florida Power& Light Co. Florida Power Corporation Florida Public Utilities 800-432-4770 407-780-2800 800-226-3545 800-700-8744 407-322-5733