Loading...
HomeMy WebLinkAbout111 S 21 St49B' 22.4' 26' r; CA h d1 cq i M EXIB ING EL C SERVICE � N GARAGE m ih NEW 3/4 PVC WATER EXISTING HVAC d) NEW 4" PVC EXISTING 4" PVC SANITARY------------- cv EXISTING DRIVEWAY 4 SITE PLAN TEED AND L INDA (SILVA) NEUJSOM eAF,...AGE RENOVATION LEGAL DESCRIPTION: BEGINNING 100111 OF NE CORNER OF 8 1/2 OF OF NWi/4 OF NE 1/4 OF SE 1/4 OF SECTION 36 TWP 19S R 30 E SEMINOLE COUNTY, RUN 8 260 FT THEN W 100FT THEN N 110FT THEN E 45FT TO P05. LESS 4 ECEPT DESCRIPTION RECORDED 11/2V18 IN OR 1198-165 AND DESCRIBED IN DEED RECORDED 4/5/33 IN OR BOOK 2565-1846 ALL IN SEMINOLE COUNTY FLORIDA NOTE: THIS RENOVATION 18 PHASE 1 OF THE RENOVATION / EXPANSION OF THE EXISTING HOUSE. FLOOR PLANS OF THE EXISTING AND THE PROPOSED REMODEL ARE ATTACHED. REMODELING OF THE HOUSE IS TO BE PERMITTED SEPARATELY INDEX TO DRAWINGS 2 3 0 5 0 COVER / SITE FLOOR PLAN ELEVATION5 WERE, m DIMENSION PLAN ELECTRIC PLAN PLUM51NG PLAN T`T'i=IC. AL WALIL; �05/01/2001 ANDREW KUTX ARCHITECT AR 0006451 (401) 322 3855 FOUNDATION NOTES ALL CONCRETE SHALL BE MININUM 2500 PSI AT 28 DAYS ALL FILL SHALL BE COMPACTED TO 95% OF MODIFIED PROCTOR 0 14% MOISTURE ALL REINFORCING STEEL SHALL BE 5 OR GREATER GRADE 60 DEFORMED STEEL ALL REINFORCING STEEL 18 TO HAVE A MINIMUM OF 3 INCH CONCRETE COVERAGE ALL REINFORCING STEEL JOINTS SHALL LAP A MINIMUM OF 40 BAR DIAMETERS OR 25 INCHES WHICHEVER IS GREATER VAPOR BARRIER SHALL BE 6 MILL POLYETHYLENE THE FOUNDATION HAS BEEN DESIGNED FOR A SOIL BEARING CAPACITY OF 2500 PSF. THE COMPACTED SOIL SHALL BE VERIFIED BY A GEOTECHNICAL TESTING LAB ALL LUMBER IN CONTACT WITH MASONRY SHALL BE PRESSURE TREATED NOTE: JACK UP EXISTING STRUCTURE AND CONSTRUCT NEW FOUNDATION AND FLOOR SLAB. SEE TYPICAL WALL SECTION. BRACE STRUCTURE AT ALL TIMES TO SECURE AGAINST LATERAL MOVEMENT IN ANY DIRECTION. EXISTING DOOR OPENING NEW HEADER NEW 2-2x10 W ELECTRIC 1/2" FLITCH PANEL FETAL-- --- — HOL° I DRYS I 16" SHELF PANEL WITH STOR CAB ABOVE ro u GARAGE / =W ROOM -�- (EXISTM ADJACENT HOUSE IS AT 24") Ali� � •. a . 1 K OBATHROOM(3�2x80 ANE NEW FOOTING AND I NEW CONC SLAB I I EXISTING WALLS REPLACE ANY BAD STUDS RESHEATH t RESIDE L--- ----- ----------------------J FLOOR FLAN 6CALEs V4° ■ P-0' REPLACE EXISTING SLIDING GARAGE DOOR WITH 2-48x80 FABRICATED DOORS EXISTM6 ROOF 4ARDIE BOARD 40RIZONTAL SIDING V TO WEATHER Ix4 TRIM SOUTH WEST EAST NORTH t /1 NOTE: ANY CHANGE IN FLOOR HEIGHTS REMIRES A CHANGE IN RISER / TREAD DIMENSIONS SUCH THAT THE SUM OF 2 RISERS + 1 TREAD IS GREATER THAN 24 AND LESS THAN 25 23'-2"+/- DECK 21 r b "GARAGE it STAIRS D IMEN51ON FLAN SCALES V4° - P-O- 3-1/0 CU I%CU I5" CONDUIT 125 AMP 125 AMP PANEL MAIN DISCONNECT 30/40 CIRCUITS 120/240 VOLT I PH MLO Cu-3-1/0 Cu I%CU IN 15" CONDUIT �6TO EXISTING SERVICE 5/8" x I0' CU CLAD GROUNDROD (2) ELECTRIC RISER DIAGRAM ELECTRICAL NOTES PROVIDE INSULATED BOXES FOR ANY RECESSED INCANDESCENT FIXTURES ALL ELECTRICAL DEVICES SHALL BE RESIDENTIAL GRADE OR BETTER ALL BRANCH CIRCUITS SHALL BE COPPER MIN 012 ALL PRIMARY CIRCUITS SHALL BE COPPER. NO ALUMINUM WIRE IS ALLOWED PAST THE METER ALL FEEDER CONDUCTORS SHALL HAVE COMPRESSION CONNECTORS UNDERGROUND CONDUIT MAY BE PVC WHERE ALLOWED BY CODE ALL ELECTRICAL WORK SHALL MEET THE NATIONAL ELECTRICAL CODE. WIRING AND CONDUIT SHALL BE SIZED TO MEET OR EXCEED THOSE REQUIREMENTS NEW 125A PANEL 15" CONDUIT TO EXISTING SERVICE - ---------------------- I 50 CFM EXH FAN ILwp W SCREENED WALL CAP ELECTRIC FLAN GCoALE. 114' - P-m' J§ 220 V 0 DUPLEX OUTLET O,wi GROUND FAULT OUTLET ow' WATERPROOF OUTLET 036 RAISED OUTLET d TELEPHONE/COMPUTER O RECESSED INCANDESCENT 5 SWITCH 63 SWITCH, 3 WAY ,o, EXHAUST FAN, OR MOTOR SURFACE INCANDESCENT O WATER HEATER r PANEL EIJ SURFACE INCANDESCENT T-1 WATER NEATER TIMER DRAIN PAN F3/4" 110 DEGREE RELIEF 1/2" PVC TO SYSTEM _j T4P RELIEF 311 vom pJ wtal s ( `KtNS CCr. c�e�� e 1/2" COPPER UNION 3/4" CW SUPPLY r " PVC 2" �C HB WC2O •-• 0-1 0.1/2" P4T DRAIN p RELIEF II 2" _ VALVE VALVE II o • I I I C., 1/2" COPPER DRYS SHUTOFF 3/4" PVC FROM 3/4" TO 50 GAL i TO DRIP PAN II VALVE EXISTING SERVICE GRADE! 1 I I ' ♦ % SEE SITE PLAN OUTSIDE I b" CLEAR WASTE -�i ALL AROUND 18 GA STEEL DRIP PAN r e ees e e ®e eee® C� 3 ' �A WATER HEATER DETAIL x 4"PVC RECESSED SLOPE MIN 1/10" WASHER HOOKUP PER FOOT TO WITH DRAIN WATER PAN EX18tING SANITARY L OPTION PLUMBING NOtEB NEWT' TRAP PRIME DRAIN PAN THE DRAIN FROM ALL HOSE BIBS SHALL HAVE NON REMOVEABLE THE TOILET SUPPLY 000 VACUUM BREAKERS THE POTABLE WATER SYSTEM SHALL BE DISINFECTED NOTE: INSTALL COLD WATER IN ACCORD WITH THE PLUMBING CODE SHUTOFF OUTSIDE OF GARAGE TEST THE WATER SYSTEM AT 125 PSIG FOR 24 HOURS BEFORE COVERING UP ANY WATER SUPPLY LINES 000 TEST THE WASTE PIPING WITH A 10 FT HEAD OF WATER FOR NOT LESS THAN 30 MINUTES ol 100 WATER AND SANITARY PLUMBING AND LINES SHALL BE SCHEDULE 40 PVC EXCEPT HOT WATER WHICH SHALL BE CPVC ABOVE GRADE AND TYPE K COPPER BELOW GRADE FLUM51NG FLAN SCSAI.Es V4° ■ P-O° 511/Zzo SOLID 2x6 BLOCKING 2x6 COLLARTIES (4 ® 24 EXISTING 2x6 COLLAR TIE EVERY RAFTER MIN 2-1/*( 3 SCREWS EACH END -IORIZONTAL HARDIE BD SIDING 3" TO WEATHER ON 15# FELT )/ER 1/2" PLYWOOD - NAIL 6" k WITH 8d ?x4 DIAGONAL BRACING AT INTERSECTION OF COLLAR IE5 AND RAFTERS. SECURE ENDS WITH 51MP50N k34 CLIP. :ONTIN000S 5PF 2x4 LATERAL BRACE IN LINE WITH NAGONAL BRACING 2x4 ® 24" OC ED(ISTING GABLE END CONSTRUCTION 1/2" =1'-O" ne H1 e MAS A. 2x6 SOLID BLOCKING FIRST 3 RAFTER SPACES SIMPSON H-3 CONNECTOR ._ EVERY STUD NAIL 8-8dx1112 EXISTING SLAB 2x4 PT PLATE CUT BACK TO INSTALL NEW FOOTING 4" CONC. SLAB REINF. W/ 6x6, 0I011AlF OVER D6 VISa EN VAPOR BARRIER OVER CLEAN, COMPACTED, TERMITE TREATED FILL. T*1"F I CAL WALL SE CT I Old 1/2 11 O = 011 SIMPSON H-1 CONNECTOR EVERY RAFTER 6-8d 11/2 0 RAFTERS 4-8d ® PLATE f —1'-4" --� h1 NEW EDGE TRIM AND FLASHING 1x8 PT - NOTCH FOR RAFTERS GALV METAL DRIP bQ PT DRIP bt6 PT FASCIA NEW HARDIE BOARD SIDING. 6 " TO THE WEATHER - OVER 15# FELT. ON NEW 1/2" PLYWOOD. SECURE PLYWOOD TO STUDS WITH 8d AT 6" OC SIMPSON "MAO" CONNECTOR 0 32" OC. NAIL: 2-10d x 11/2 51DE 4-10d x 11/2 TOP 1/2x2 PT CONTIN BEHIND BOTTOM OF SIDING - LAP FOUNDATION 1" FINISH GRADE VARIES CONC. FOOTING 125M PB.IJ WITH 2 +5 CONTINUOUS NOTE: STRUCTURE DESIGNED TO RESIST 100 MPH WINDS 'k )7 Aln.00wtlkk EXISTING HOUSE 101 101 a iREMODELED HOUSE _ -J PLANS REVIERVi*'D CITY OF SANFOr" SANFORD BUILDING DEPT. THESE PLANS ARE REVIEWED AND CONDITIONALLY ACCEPTED FOR PERMIT. A PERMIT ISSUED SHALL BE CONSTRUED TO BE A LICENSE TO PROCEED WITH THE WORK AND NOT AS AUTHORITY TO VIOLATE, CANCEL, ALTER. OR SET ASIDE ANY OF THE ,PROVISIONS OF THE TECHNICAL CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT -THE BUILDING DEPT FROM THEREAFTER REr)u1RNG A CORREC- TION OF ERRORS ON THE PLANS. qONSTRUCTION OR OTi-4:R vjj-)4-, Or -THE CODES. Cit .1y Model Codes in cffc.,--t: St tafld-ird Gufiiding Code 1997 ed. Standaid P'Urlbii 9 Code 1997 ed. Qla Indqrd'!'Aechanical Code 1997 ed. Naf:cjr;:.'! k'ode 19096 ed. See --1-,JDMENTS FL. Atcc-.c 1 OD97 FL. 7 t FERMI #01./682- s- /5 ovx'17014F F Ic1. ", V