Loading...
HomeMy WebLinkAbout1137 W Airport Blvd (3)Florida Energy Efficiency Code For Building Construction Florida Department of Community Affairs EnergyGauge FlaCom v 2.11 FORM 40OA-2004 Whole Building Performance Method for Commercial Buildings Jurisdiction: SANFORD, SEMINOLE COUNTY, FL (691500) Short Desc: BRIOBLDG#2 Project: BRIO BUILDING #2 - TENANT Owner: Address: 1137 WEST AIRPORT BLVD BRIO COMMERCE CENTER BUILDING #2 City: SANFORD State: FL PermitNo: 0-- Zip: 0 Storeys: 1 Type: Office *Conditioned Area: 560 * denotes lighted Class: Renovation to existing building *Cond + UnCond Area: 560 area. Does not include wall crosection areas Max Tonnage: 3.0 (if different, write in) Compliance Summary Component Design Criteria Result Gross Energy Use 604.95 792.03 PASSES LIGHTING CONTROLS EXTERNAL LIGHTING HVAC SYSTEM PLANT WATER HEATING SYSTEMS PIPING SYSTEMS Met all required compliance from Check List? PASSES None Entered PASSES None Entered PASSES None Entered Yes/No/NA IMPORTANT NOTE: An input report Print -Out from EnergyGauge Com of this design building must be submitted along with this Compliance Report. 3/8/2006 EnergyGauge FlaCom v 2.11 FORM 40OA-2004 CVMFLIANCL CERTIFICATION: I hereby certify that the plans and specifications covered by this calculation are in compliance with _ the Florida Energy Efficiency Code. �- �y PREPARED BY: GUS BOBES JR P.E. DATE: I hereby certify that this building is in compliance with the Florida Energy Efficiency Code. Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed, this building will be inspected for compliance in accordance with Section 553.908, F.S. BUILDING OFFICIAL: DATE: OWNER AGENT: DATE: If required by Florida law, I hereby certify (*) that the system design is in compliance with the Florida Energy Code. ARCHITECT: ELECTRICAL SYSTEM DESIGNER: LIGHTING SYSTEM DESIGNER: MECHANICAL SYSTEM DESIGNER: PLUMBING SYSTEM DESIGNER: REGISTRATION No. (*) Signature is required where Florida Law requires design to be performed by registered design professionals. Typed names and registration numbers may be used where all relevant information is contained on signed/sealed plans. 3/8/2006 EnergyGauge F1aCom v 2.11 FORM 40OA-2004 2 • - - Project: BRIOBLDG#2 Title: BRIO BUILDING #2 - TENANT Type: Office (WEA File: Orlando.TMY) Whole Building Compliance Total ELECTRICITY(MBtu/kWh/$ AREA LIGHTS Design 75.50 $604.95 75.50 12,099.00 $604.95 12.25 1,960.00 $98.00 Reference 100.00 $792.03 100.00 16,033.00 $792.03 11.70 1,886.00 $93.17 MISC EQUIPMT 7.68 7.68 1,231.00 1,231.00 $61. SS $60.81 PUMPS & MISC 0.18 0.18 17.00 31.00 $0.85 $1.53 SPACE COOL 25.96 21.39 4,160.00 3,424.00 $208.00 $169.15 VENT FANS 29.43 59.05 4,731.00 9,461.00 $236.55 $467.37 .redits & Penalties (if any): Modified Points: = 75.51 PASSES External Lighting Compliance Description Category Allowance Area or Length ELPA CLP (W/Unit) or No. of Units (W) (W) (Sgft or ft) None 3/8/2006 EnergyGauge FlaCom v 2.11 FORM 40OA-2004 3 Project: BRIOBLDG#2 Title: BRIO BUILDING #2 - TENANT Type: Office (WEA File: Orlando.TMY) Lighting Controls Compliance Acronym Ashrae Description Area No. of Design Min Compli- ID (sq.ft) Tasks CP CP ance PrOZo1Spl 16 Office - Open Plan 560 1 2 1 PASSES PASSES Project: BRIOBLDG#2 Title: BRIO BUILDING #2 - TENANT Type: Office (WEA File: Orlando.TMY) System Report Compliance PrOSyl System 1 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled < 65000 Btu/h 13.00 10.00 13.00 PASSES Cooling Capacity Air Handling Air Handler (Supply) - 0.45 0.90 PASSES System -Supply Constant Volume PASSES Plant Compliance Description . Installed Size Design Min Design Min Category Comp No Eff Eff IPLV IPLV liance None 3/8/2006 EnergyGauge FlaCom v 2.11 FORM 400A-2004 4 Project: BRIOBLDG#2 Title: BRIO BUILDING#2 - TENANT Type: Office (WEA File: Orlando.TMY) Water Heater Compliance Description Type Category Design Min Design Max Comp Eff Eff Loss Loss liance Water Heater 1 Electric water heater > 12 [kW] 0.85 0.02 267.41 PASSES PASSES Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance [inches] Runout? Temp [Btu-in/hr Thick [in] Thick [in] [F] SF.F] None 3/8/2006 EnergyGauge FlaCom v 2.11 FORM 400A-2004 Project: BRIOBLDG#2 Title: BRIO BUILDING #2 - TENANT Type: Office (WEA File: Orlando.TMY) Other Required Compliance Category Section Requirement (write N/A in box if not applicable) Check Infiltration 406.1 Infiltration Criteria have been met El System 407.1 HVAC Load sizing has been performed Ventilation 409.1 Ventilation criteria have been met El ADS 410.1 Duct sizing and Design have been performed T & B 410.1 Testing and Balancing will be performed Motors 414.1 Motor efficiency criteria have been met Lighting 415.1 Lighting criteria have been met O & M 102.1 Operation/maintenance manual will be provided to owner Roof/Ceil 404.1 R-19 for Roof Deck with supply plenums beneath it Report 101 Input Report Print -Out from EnergyGauge F1aCom attached? 3/8/2006 EnergyGauge FlaCom v 2.11 FORM 40OA-2004 6 EnergyGauge FlaCom v 2.11 INPUT DATA REPORT Proiect Information Project Name: BRIOBLDG#2 Orientation: North Project Title: BRIO BUILDING #2 - TENANT Building Type: Office Address: 1137 WEST AIRPORT BLVD Building Classification: Renovation to existing building BRIO COMMERCE CENTER BUILDING #2 State: FL No.of Storeys: 1 Zip: 0 GrossArea: 560 Owner: Zones No Acronym Description Type Area Multiplier Total Area lsfl lsfl I PrOZoI Zone I CONDITIONED 560.0 I 560.0 Spaces No Acronym Description Type Depth Width Height Multi Total Area Total Volume IN IN IN plier [sf] lcfl 3/8/2006 EnergyGauge F1aCom v 2.11 1 A In Zone: - PrOZol 1 PrOZolSpl Zo0Sp1 Office - Open Plan 28.00 20.00 9.00 1 560.0 5040.0 Lighting No Type Category No. of Watts per Power Control Type No.of Luminaires Luminaire [W] Ctrl pts In Zone: PrOZol In Space: PrOZolSpl 1 Recessed Fluorescent - General Lighting 1 640 640 Manual On/Off 2 EJ No vent Walls No Description Type Width H (Effec) Multi Area DirectionConductance Heat Dens. R-Value IN [ft] plier [sf] F sf. Btu/hr. [ ] Capacity p ty [Ib/cf] [h.sf.F/Btu] [Btu/sf.F] In Zone: PrOZol 1 PrOZo1Wal 0.5 Ply/35/8" Mtl 20.00 10.00 1 200.0 North 0.0798 0.5388 7.98 12.54 std@24"oc/R 11 /0.5" Gyp 2 PrOZo1Wa2 Metal 20.00 12.00 1 240.0 South 0.0957 0.7570 16.80 10.45 siding/R 11 Batt/0.5" Gyp Windows No Description Type Shaded U SHG Vis.Tr W H (Effec) Multi Total Area [Btu/hr sf F] IN [ft] plier [sf] In Zone: PrOZol In Wall: Pr0Zo1Wa2 1 PrOZolWa2Wil SINGLE CLEAR No 1.0018 0.81 0.88 17.00 4.00 2 136.0 3/8/2006 EnergyGauge FlaCom v 2.11 Doors No Description Type Shaded? Width H (Effec) Multi Area Cond. Dens. Heat Cap. R-Value IN IN plier [sf] [Btu/hr. sf. F] [lb/cf] [Btu/sf. F] [h.sf.F/Btu] In Zone: In Wall: Roofs No Description Type Width H (Effec) Multi Area Tilt Cond. Heat Cap Dens. R-Value [ft] IN plier [sf] [deg] [Btu/hr. SE F] [Btu/sf. F] [lb/cf] [h.sf.F/Btu] In Zone: PrOZol 1 PrOZo1RD Mtl Bldg Roof/R-19 20.00 28.00 1 560.0 0.00 0.0492 1.34 9.49 20.34 ❑ Batt Skylights No Description Type U SHGC Vis.Trans W H (Effec) Multiplier Area Total Area [Btu/hr sf F] IN IN S [fl [Sfl In Zone: In Roof: Floors No Description Type Width H (Effec) Multi Area Cond. Heat Cap. Dens. R-Value IN[ft] plier [sf] [Btu/hr. sf. F] [Btu/sf. F] [lb/cf] [h.sf.FBtu] In Zone: PrOZol 1 ' PrOZolFll Concrete floor, 20.00 28.00 1 560.0 0.5987 9.33 140.00 1.67 ❑ carpet and rubber pad 3/8/2006 EnergyGauge F1aCom v 2.11 3 Systems PrOSyl System 1 Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System (Air Cooled < 65000 Btu/h Cooling 36000.00 13.00 13.00 Capacity) 2 Air Handling System -Supply (Air Handler (Supply) - 1200.00 0.45 Constant Volume) Plant Equipment Category Size Inst.No Eff. IPL V Water Heaters W-Heater Description Capacit Cap.Unit UP Rt. Efficienc Loss 1 Electric water heater 50 [Gall ] 16382 [kW] 0.8500 [Ef] 0.0200 [Btu/h] Ext-Lighting Description Category No. of Watts per Area/Len/No. of units Control Type Wattage Luminaires Luminaire [sf/ft/No] [W] No Type Piping Operating Insulation Temperature Conductivity [F] [ Btu-in/h.sf.F] Nomonal pipe Insulation Is Runout? Diameter Thickness [in] [in] 3/8/2006 EnergyGauge F1aCom v 2.11 4 I ❑■ FM Fenestration Used Name Glass Type No. of Glass SHGC Conductance VLT Panes [Btu/h.sf.F] ApLbWndl SINGLE CLEAR 1 1.0018 0.8150 0.8810 ❑ Materials Used Mat No Acronym Description Only R-Value RValue Thickness Conductivity Density SpecificHeat Used [h.sf.F/Btu] IN [Btu/h.ft.F] [lb/c f] [Btu/Ib.F] 187 Mat1187 GYP OR PLAS BOARD,1 /21N No 0.4533 0.0417 0.0920 50.00 0.2000 ❑ 151 Mat1151 CONC HW, DRD, 140LB, 41N No 0.4403 0.3333 0.7570 140.00 0.2000 ❑ 178 Matl178 CARPET W/RUBBER PAD Yes 1.2300 211 Mat1211 POLYSTYRENE,EXP.,1/2I No 2.0850 0.0417 0.0200 N, 1.80 0.2900 ❑ 12 23 Matl12 Mat123 3 in. Insulation No 10.0000 0.2500 0.0250 2.00 0.2000 ❑ 4 Mat14 6 in. Insulation Steel siding No 20.0000 _ 0.5000 0.0250 5.70 0.2000 ❑ 94 Mat194 BUILT-UP ROOFING, No 0.0002 No 0.0050 26.0000 480.00 0.1000 El 0.3366 0.0313 0.0930 70.00 0.3500 El Constructs Used 3/8/2006 EnergyGauge FlaCom v 2.11 5 No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sLF] [lb/cf] [h.sf.F/Btu] 1004 Concrete floor, carpet and rubber pad No No 0.60 9.33 140.00 1.6703 ❑ Layer Material Material Thickness Framing No. IN Factor 1 151 CONC HW, DRD, 140LB, 41N 0.3333 0.00 2 178 CARPET W/RUBBER PAD 0.00 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf[ [h.sf.FBtu] 1015 0.5 Ply/35/8" Mtl std@24"oc/R11/0.5" Gyp No No 0.08 0.54 7.98 12.5383 ❑ Layer Material Material Thickness Framing No.IN Factor 1 211 POLYSTYRENE,EXP.,1/2IN, 0.0417 0.00 ❑ 2 12 3 in. Insulation 0.2500 0.00 ❑ 3 187 GYP OR PLAS BOARD,1/21N 0.0417 0.00 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.F/Btu] 1020 Metal siding/R11Batt/0.5"Gyp No No 0.10 0.76 16.80 10.4535 ❑ Layer Material Material Thickness Framing No. IN Factor 1 4 Steel siding 0.0050 0.00 ❑ 2 12 3 in. Insulation 0.2500 0.00 ❑ 3 187 GYP OR PLAS BOARD,1/21N 0.0417 0.00 ❑ 3/8/2006 EnergyGauge F1aCom v 2.11 6 No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sLFBtu] 1047 Mtl Bldg Roof/R-19 Batt No No 0.05 1.34 9.49 20.3366 ❑ Layer Material Material Thickness Framing No. IN Factor 1 94 BUILT-UP ROOFING, 3/8IN 0.0313 0.00 ❑ 2 23 6 in. Insulation 0.5000 0.00 3/8/2006 EnergyGauge FlaCom v 2.11 7 4_ .... - - . .