Loading...
HomeMy WebLinkAbout500 Airport Blvd (2)SITE LOCATION PLAN (NTS) GENERAL NOTES RENOVATION PLANS FOR COLLISON FUNERAL HOME SCOPE OF WORK : EXTEND ROOFLINE OUT OVER EXISTING PATIO TO CREATE A COVERED PORCH .._........._......... _.._ _...:__.�WI 12 VA ►������������ 1 mac+ �. � ■ ;. � ■ ■ EXISTING BUILDING L----------___--_--____J EXISTING BUILDING 1. AGURED DIMENSIONS TAKE PRECEDENCE OVER SCALED MEASUREMENTS. DO NOT SCALE DRAWINGS. 2. DETAILED DRAWINGS AND LARGER SCALE DRAWINGS TAKE PRECEDENCE OVER SMALLER SCALE DRAWINGS. 3. ITEMS NOTED ON DRAWINGS ARE RELOCATED FROM THIS PROJECT, NEW OR TO BE PROVIDED AND INSTALLED BY CONTRACTOR UNLESS NOTED OTHERWISE. 4. THE MANUFACTURER'S STANDARD DETAILS OR APPROVED SHOP DRAWINGS / DATA SHEETS, IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS, SHALL APPLY UNLESS OTHERWISE DETAILED IN CONSTRUCTION DOCUMENTS. DIMENSIONING UNLESS OTHERWISE NOTED, PLAN DIMENSIONS ARE TAKEN FROM: C. FACE OF METAL/WOOD STUD TO FACE OF METAL/WOOD STUD. 500 AIRPORT BLVD E. SANFORD, FL 32773 CITY OF SANFORD - SEMINOLE COUNTY, FLORIDA GENERAL Parcel1d: 01.20.30-512-0000-027A Tax Dlzict: S1-SANFORD Owner: COLLISON HOLDING CO-SANFORD Address: 3806 HOWELL BRANCH RID WINTER PARK FL 32M Property Address: 500 AIRPORT BLVD E. SANFORD 32773 Facility Name: Dor: 76-MORTUARIES/C EMtIERI ES APPLICABLE CODES INCLUDE BUT ARE NOT LIMITED TO THE FOLLOWING: 2001 FLORIDA BUILDING CODE W/ LATEST REV. FLORIDA BUILDING CODE, PLUMBING FLORIDA BUILDING CODE, MECHANICAL 1997 NATIONAL ELECTRICAL CODE 2001 NFPA - LIFE SAFETY CODE 101, 2000 EDITION FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION MDO;D USE: GENERAL OFFICE / ASSEMBLY TOTAL COVERED AREA 460 S.F. OCCUPANCY: ASSEMBLY / MORTUARY CHAPEL CONSTRUCTION CLASSIFICATION � UNPROTECTED, UNSPRINQaED DESIGNED FOR 120 MPH WINDLOADS DRAWING INDEX CVR COVER SHEET / MISC. NOTES A 1.0 OVERALL SITE PLAN A2.0 CONCRETE SLAB LAYOUT A3.0 HVAC / ELECTRICAL LAYOUTS P 1.O PLUMBING RISER / PLAN - FIXTURE SCHEDULE & LAV. DETAILS P2.0 PLUMBING DETAILS M 1.0 MECHANICAL / HVAC PLAN, NOTES & DETAILS Sanford Fire Date: BUILDING DESIGN CONSULTANT: CREATIVE PLANNING & DESIGN 1 899 KENTUCKY AVENUE, WINTER PARK, FL 32789 PHONE: 407-41 5-3201 - FAx. 407-599-1984 CONTACT: R. CASEY NELSON ISSUE DATE: 2/12/2005 CREATIVE PLANNING DESIGN 00 000 00 0000 ,899 f KInter we A WlnOer Perk, F1 PHONE. FAX: 9. 7fi43 FAX: 407. 829. 7647 RMU p lf3v s lJJ LL I— 00 Lu 0 qJ LL � w z � LL LLL O z U 0 N -D J O U APff� 1 rv:sa�: OWE m E M21M I J U R U S . I i caNc POWE2 ❑ a I PaIE i I 12 I Pro N!O carc UM wO) PARCEL 3 03 1$� g R ,4 loO m. I N I � � I Z, r; O I AG PAD lax POKER N I POLE m PARCEL 1 Tiwc��I `�canc C'N I IZ p 1 STORY care l , BLOCK/STUCCOIBRICK BUILDPIG ir I I I I /f a.r I / PWAER I ASPHALT I ° I GAP P ` ASPHALT I+ IA to I IQ I 1�� PARCEL 2 d Z 91 I� �c�Cil i P.O.B. PARCEL 2 N g9 3 °B 28• ° 4 a -°; • �° cov. PLANTER v � � 20i I e b I ASPHALT Si �51 SUMNRESS PARCI-=L 0� CAP03M t0l OwaEAD ELM P.O.B. PARCELS 1 a! 3 SET MN& CAP 6J3M2J Jog NJ►BR, a-M PLAN VERSK)N: sam DATE 2FIZ oB CONC. m e A 41.37 ❑ a COVERED + AREA 38.w COV. 1z CONC. EXISTING 1 STORY BLOCK/STUCCO/BRICK § BUILDING o jil a M a 38 ...........�............... COV. _ PLANTER Eb3TING CONC. PATIO 2 y 25 ,f • a PLANTER.........................�......... 6 � ro .wr FOR ENLARGED AREA . SEE TMS SHEET BUILDING LAYOUT EXISTING SIDEWAU W-8 _� w0) z IL z O J J O U THICKENEP EDGE, 2 # 5 I REBARS WAY WAY .I.LLJ In I (FIELD VE Z =,: S d 12" DEEP 16" X 16" I PADS AS L CATED ON TiT Z PLAN ARE (STING. cn 77 1 FIEL VERIFIED CONCRETE SLAh (EXISTING) 1 /2"=1'-(Y" 15/32" PLYWOOD OR 7/16" O.S.B. i I I NAILED PER ROOF NAILING DETAIL 12 12 I MATCH EXISTING SLOPE I12 I MATCH EXISTING SLOPE ` \ (MATCH EXISTING SLOPE I FASCIA TO MATCH D(ISTING. PAINT OR i STAIN TO MATCH I ADJACENT FINISH I HUGHES RT 16 UPL. 744 (EACH SIDE( OR SIMP. MST 12 UPL. 640 (4-1 Od X 1 1T) ELEV. TO MATCH CONVENTIONAL FRAMED i I•, EXISTING ROOF 2X RAFTERS AT 16' (2) 2X8 OR 4X8 . •. i t O.C., TO MATCH GLUE -LAM. BEAM BLOCKING AS READ TO EXISTING SLOPE (TYP.)- I IN POST / BEAM MATCH EXISTING %a" EXTERIOR GRADE I CONNECTOR AS BOXED BEAM. DIMENSIONS (TYP.) GYPSUM OR GREEN RIDGE BOARD SHALL BE SPECIFIED BOARD SCREWED TO 2X TO MATCH UNDERSIDE OF RAFTERS EXISTING.-2X'S LAPPED 1X USED TO BOX i - - PROVIDE (1) ONTO EXISTING RIDGE, IN BEAM TO MATCH VENTILATION SCREEN I (1)EACH SIDE.(2,V LAP I EXISTING BEAMS PAINT I HUGHES PC44 UPL 1480 ON EA. SLOPE EACH WAY) STAGGERED OR STAIN TO MATCH 14 - 16d TO MATCH EXISTING. I NAIL PATTERN AT 4' ( ADJACENT FINISH. I OR: SIMPSON PC44 UPL 1420 O.C., TEtB EACH SIDE. i ( 14 - 16d I I SLAB SLOPES AT 1 /4' � PER FT. AWAY FRONT i I OF BUILDING 7/8" STUCCO ON 1 /2' PLYWOOD ON P.T. SYP. 4x4 POST i 4" CONC. SLAB (EXISTING) HUGHES PA 4X40 UPL 1515 3 - 16d PER EA. FLAP OR: SIMPSON ABU44 W / 14 - 16d COMMONS DRIVEWAY TO POST - (1) 5/8" i EXP. BOLT TO SLAB - bD ALA. b I ° I e I I I I I Ae I I I I ( hr I I I 16"X16» n 16 X16 TF WOOD POST COLUMN 1 I I III III 12- x 16' x 16" coNc £t MONO FOOTING DETAIL ( I I I I FOOTER W/ 2 #5 ROD EACH WAY (EXISTING) m o x Q t- N Lu � w z w z J 0 I "NUWaL RM vgmm ME DATE b,2ria a■ Z Z z �j • 03 03 °~ L� J Z JZ 3 03 U C7 U U U Z J J Q J Q Vr U0 Q v J Q /� 6'-0"t .I ass•+ R�11•� v SLOPE 1,1 SLOPE C9 wz oEn U. x 0� J UZ J ,a 6'-Oot SLOPE SLOPE I!I SLOPE l+l SLOPE W-O"t Q ------ U ------ C/LOFCOLUMNS @8" LL BACK FROM EDGE OF TT EXISTING SLAB 1X FASCIA TO MATCH SIZE OF EXISTING 4X4 P.T. 4X4 P.T. 4X4 P.T. COLUMN COLUMN COLUMN NOTE: REFER TO DETAIL FOR FRAMING AND HOLD DOWN REQUIREMENTS ROOF FRAMING PLAN 1 /2"=1'-O" CItEA'I'IVE PLANNING DESIGN 0 00 000 000 00 less KenbAy Aw Winter Perk, R 09 PHOE: 407. GM. 7a43 FAR: 407, 629. 7647 MAL CASEY40WATMMANSROOKOOM =m��;�a �@6s LL is q2�C1���� ,yWSRi V0 1§1 cl o� W ! d [= p � tS41` W LL. 0 x 4J �ZZ W z LL z O J J O 0 JOB NJWEFL FLAN z z C9 0 wvx_~i wN z w? Z w oCA m 5'-0"' Q2 ROOF EDGE (a) 5'-0" 1----------------------------------------------- 0' (D o ------------------------------------------------------' .:^ RIDGE 51 --------------------------- ----------------- ---------; o 10 1 0 �Q�� O j 4' 1 i ----------------- w - ----- - ------ - - - - -z PNEUMATIC NAILS: PNEUMATIC OR MECHANICALLY DRIVEN NAILS WILL BE ACCEPTED UNDER THE FOLLOWING CONDITIONS; A. MINIMUM NAIL SIZE: 6d OR LARGER SPIRAL SHANK WITH: -MINIMUM SHANK DIAMETER - .099 -MINIMUM LENGTH - 2 1/4- -MINIMUM HEAD DIAMETER - 1 5/64" B. MINIMUM NAIL SPACING ( MIN. SHEATHING 7/16") AREA EDGE FIELD ZONE 1 6" 8" ZONE 2 4' 6" ZONE 3 6" 8" ZONE 4 4' 6" GABLE TRUSS 4' O.C. NAILING PATTERN ROOF FRAMING DETAIL N.T.S. ZONE 10 118"o.. INTERMEDIATE.N NAILS ®6"o.c. AT EDGES, AND ZONE Q I I USE 8d COMMON NAILS 0 6"o.c. AT ALL FIELDS. I ZONE 0 11 USE 8d COMMON NAILS 0 4"o.c. AT ALL FIELDS. I Zj2 2 0 2 2 2 1� 2 a-� �1 O 2IT 2 O Oi O3 2 3 3 2 ROOF SHEATHING NAILING ZONE NOTES N.T.S. ROOF PLAN NOTES: 1. ALL RAFTERS SHALL HAVE A TOP CHORD PITCH OF 6:12t. CONTRACTOR TO FIELD VERIFY AND MATCH EXISTING ROOF SLOPES 2. ALL OVERHANGS SHALL BE 2'4r UNLESS NOTED OTHERWISE. 3. ALL RAFTERS, HEADER, BEAMS, AND OTHER LOAD BEARING MEMBERS SHALL BE ENGINEERED BY FL, REGISTERED P.E. 4. THIS PLAN IS TO SHOW BASIC ROOF CONFIGURATION. 5. ATTACH EACH RAFTER, SUPPORT WITH HURRICANE ANCHOR PER DETAIL 6. ROOF DECK IS % C.D.X. PLYWOOD OR ib O.S.B. ATTACH PER NAILING SCHEDULE. RAFTER NOTES: 1. CONTRACTOR TO FIELD VERIFY EXISTING DIMENSIONS, SPINS, PITCHES, AND ANY CONDITIONS WHICH COULD ALTER OR AFFECT TRUSS DESIGN. LUMBER: 1. ALL STRUCTURAL LUMBER (INCLUDING BUT NOT LIMITED TO: JOIST, BEANS, RAFTERS, STUDS, PLATES AND POSTS) SHALL BE SOUTHERN YELLOW PINE, GRADE #2, KID 19% OR BETTER (Fb FOR LUMBER NOTED TO BE IN CONFORMANCE WITH VALUES LISTED IN THE NATIONAL FOREST PRODUCTS ASSOCIATION NATIONAL DESIGN SPECIFICATION SUPPLEMENT TABLE 4B), AND SHALL CONFORM TO THE NATIONAL GRADING RULE FOR DIMENSION LUMBER, THE SOUTHERN PINE INSPECTION BUREAU AND THE SOUTHERN FOREST PRODUCTS ASSOCIATION. 2. ROOF DUIFRAM: MINIMUM 1%2 PLYWOOD, C-C EXTERIOR OR OTHER PS-1 GRADE. NAILING: 8d @ 4" O.C. ALL EDGES 12" O.C. IN FIELD, ALL EDGES BLOCKED, 8d RINGSHANK NAILS @ 4" O.C. WITHIN THE FIRST 5' EITHER SIDE OF THE RIDGE AND WITHIN Y OF THE EDGE AROUND THE ROOF PERIMETER. NAILING SCHEDULE FOR WALLS AND ROOF: ROOF: WITHIN 4 FEET OF ALL EAVES, GABLES, RIDGES AND HIPS. NAIL 6" O.C. ON EDGES AND INTERMEDIATE SUPPORTS ON EACH PANEL. ALL OTHER AREAS SHALL BE NAILED 6' O.C. AT THE EDGE AND 12" O.C. IN THE INTERIOR OF THE PANEL. NAIL SHEATHING 4" O.C. INTO ALL GABLE END TRUSS TOP CHORDS. NAILS: NAILS USED IN ALL SHEATHING APPLICATIONS SHALL BE 8d, COMMON, RING OR SPIRAL SHANK, OR HOT -DIPPED GALVANIZED, HAND OR GUN -DRIVEN NAILS. GUN -DRIVEN NAILS SHALL HAVE HEAD SIZE EQUIVALENT TO HAND -DRIVEN NAILS. OTHERWISE SPACING SHALL REDUCE FROM 12" TO 10", 6" TO 5" AND 4" TO 3" IN THOSE APPLICATIONS. CONNECTION NOTES: ALL FRAME TO TRUSS CONNECTORS TO BE HUGHES OR SUBSTITUTE SIMPSON AS SHOWN ON DETAILS UNLESS OTHERWISE NOTED. 262M R, Suzy pp1'g mW Br0■ 6i w H O Z cn J H w C] Sup DATE' MX2n I