Loading...
HomeMy WebLinkAbout550 Aero Ln-� SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION Timothy Robles/Fire Marshal 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772 (407 302-2516 / FAX (407) 302-2526 Plans Review Sheet W1 Date: March 22, 2006 Business Address: 550 Aero Lane Occ. Ch. #401#38 Business Name: Adopco Building Ph. () Contractor: Spolski Construction Ph. (407) 322-8424 Fax. (407) 322-8436 Reviewed [] Reviewed with comment [X] Rejected [] Reviewed by: Timothy Robles, Fire Protection Fire Marshal Comment: Plans reviewed as Business / Industrial Occupancy. FD reserves right to require applicable code requirements if occupancy use changes. Sprinkler submitted and review. This occupancy is an Industrial occupancy 14,227 sq. ft @ one (1) person per 100 sq ft.= 27 maximum occupancy for industrial/storage area. Fire alarm monitoring required of fire sprinkler system complying with N.F.P.A. 972. A full operational fire alarm required throughout building, including, but not limited to, pull stations at each EXIT, HORN STROBES through out building with 75 D.B.s of sound, horn strobes in all bathrooms, as well as fire sprinkler monitoring , if building occupies over 100 employees. Fire Alarm plans to be submitted for review, permitting, and Inspections. 1.1 Application — New Building. Type IV @ 14,227 sq. ft . 1.2 Mixed — N/A Business& Industrial area HAS INDEPENDENT ACCESS 1.3 ,Special Definitions — N/N 1.4 Classification of Occupancy — General Industrial Occupancy Group A 1.5 Classification of Hazard of Contents — Shall complies with section 6.2 of L. S. C. 1.6 Minimum Construction — N/R 2.2 Means of Egress Components — One per 100 2.3 Capacity of Egress — O.K . (4) four 1 SANFORD FIRE DEPARTMENT FIRE PREVENTION DI VISION Timothy Robles/Fire Marshal 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772 (407 302-2516 / FAX (407) 302-2526 2.4 Number of Exits —. (4) four 2.5 Arrangement of Egress — O.K., will field verify 2.6 Travel Distance — O.K. 2.7 Discharge from Exits — O.K., will field verify 2.8 Illumination of Means of Egress — O.K.; will field verify, electrical exit signs and emergency lights required 2.9 Emergency Lighting — O.K.; will field verify 2.10 Marking of Means of Egress — O.K.; will field verify 2.11 Special Features — O.K. 3.1 Protection of Vertical Openings — N/N 3.2 Protection from Hazards — N/N 3.3 Interior Finish — Class "B" 3.4 Detection, Alarm and Communications Systems —fire alarm required 3.5 Extinguishing Requirements — as per NFPA 10, see blue prints Four fire extinguishers required. Two (2) 4A60 BC fire extinguishers required in industrial area) Two (2) 2AIOBC fire extinguishers required in office area Break room, and Main entrance. 3.6 Corridors — N/A - 4 Special Provisions - 5 Building Services 5.1 Utilities — as per LSC 7-1 5.2 HVAC — as per LSC 7-2 5.3 Elevators, Escalators, Conveyors (4A-47) — N/A 5.4 Rubbish Chutes, Incinerators, and Laundry Chutes — N/A Sanford City Code — Chapter 9 Fire Sprinklers: Required; also see 3.5 above Monitoring: Required by a U.L. listed Central Station for all mandated fire sprinklered properties 2 SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION Timothy Robles/Fire Marshal 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772 (407 302-2516 / FAX (407) 302-2526 Other: NFPA 1 3-5.1 Fire Lanes — Required if building is more than 150' from street; exception: Building has fire sprinkler system. 3-6.1 Key Box — Required; will field verify (see application) 3-7.1 Bldg. Address Number Posted and Legible — Required; will field verify w ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs EnergyGaugeFlaCom v1.22 FORM 40OB-2001 Component Performance Method for Commercial Buildings Jurisdiction: SANFORD, SEMINOLE COUNTY, FL (691500) Short Desc• Adapco Project: Adapco Solutions & Technology Owner: Adapco, Inc. Address: 550 Aero Lane City: Sanford State: FL Zip: 32771 Type: Office (Business) Class: New Finished building PermitNo: 0 Storeys: 1 GrossArea: 8088 Net Area: 8088 Max Tonnage: 7 (if different, write in) Compliance Summary Component Design Criteria Result ENVELOPE 185.95 210.53 PASSES Other Envelope Requirements - B PASSES LIGHTING POWER 11,850.00 12,088.00 PASSES LIGHTING CONTROLS PASSES EXTERNAL LIGHTING PASSES HVAC SYSTEM PASSES PLANT PASSES WATER HEATING SYSTEMS PASSES PIPING SYSTEMS PASSES Met all required compliance from Check List? Yes/No/NA IMPORTANT NOTE: An input report Print -Out from EnergyGauge FlaCom of this design building must be submitted along with this Compliance Report. 1 /4/2006 EnergyGauge FlaCom FLCCSB 0.22 COMPLIANCE CERTIFICATION: I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Efficiency Code. PREPARED BY: Kevin J. Spolski or DATE: I hereby certify that this building is in compliance with the Florida Energy Efficiency Code. OWNER AGENT- Kevin .1- fipnlski DATE: Z-) Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed, this building will be inspected for compliance in accordance with Section 553.908, F.S. BUILDING OFFICIAL: DATE: If required by Florida law, 1 hereby certify (') that the system design is in compliance with the Florida Energy Code. ARCHITECT: T. N. Davis, P.E. ELECTRICAL SYSTEM DESIGNER T. N. Davis, P.E. LIGHTING SYSTEM DESIGNER: T. N. Davis, P.E. MECHANICAL SYSTEM DESIGNER: T. N. Davis, P.E. PLUMBING SYSTEM DESIGNER: T. N. Davis, P.E. REGISTRATION #7857 #7857 #7857, I #7857 #7857 M ginnnfijrA iS required where Florida Law reauires design to be performedby registered design professionals. Typed names and registration numbers may be used where all relevant information is contained on signed/sealed r i . Project: Adapco Title: Adapco Solutions & Technology Type: Office (Business) Location: SANFORD, SEMINOLE COUNTY, FL (691500) (WEA File.• Orlando TM Envelope Compliance Design Load Criteria Zone Heating Cooling Heating Cooling Zone 1 (CONDITIONED) -16.89 52.43 -29.24 55.10 Zone 2 (CONDITIONED) 0.00 116.64 0.00 126.18 Total Loads: Desisn=185.948 Criteria=210.53 �—PASSES 1 /4/2006 EnergyGauge FlaCom FLCCSB vI.22 2 Project: Adapco Title: Adapco Solutions & Technology Type: Office (Business) Location: SANFORD, SEMINOLE COUNTY, FL (691500) (WEA File: Orlando.TM Other Envelope Requirements Item Zone Description Design Limit Meet Req. Zone 1 % Skylight - Max % Limit 0.00 5.50 Yes Zone 2 % Skylight - Max % Limit 0.00 6.70 Yes Roof Zone 2 Exterior Roof- Max Uo Limit 0.05 0.07 Yes Meets Other Envelope Requirements Project: Adapco Title: Adapco Solutions & Technology Type: Office (Business) Location: SANFORD, SEMINOLE COUNTY, FL (691500) (WEA File: Orlando.TM External Lighting Compliance Description Category Allowance Area or Length ELPA CLP (W/Unit) or No. of Units (W) (W) (Sgft or ft) Ext Light 1 Exit (with or without Canopy) 25.00 7.0 175 150 Design: 150 (W) PASSES Allowance: 175 (W) Project: Adapco Title: Adapco Solutions & Technology Type: Office (Business) Location: SANFORD, SEMINOLE COUNTY, FL (691500) (WEA File: Orlando.TM Lighting Power Compliance Space Ashrae Description Area Height No. of AF Design Effective Allowance ID (sq.ft) (ft) Spaces (W) (W) T) Zn I Spl 46 Storage & Warehouse - Fine 3.088 10.0 1 1.00 3000 3000 3,088 Active Storage Zone 2 26 Offices (Partitions>4.5 ft 5,000 10.0 1 1.00 8850 8850 9.000 below ceiling) Enclosed offices, all open plan offices without partitions Design 11850 (W) PASSES Effective: 11850 (W) Allowance: 12088 (W) 1/4/2006 EnergyGauge FlaCom FLCCSB v1.22 Project: Adapco Title: Adapco Solutions & Technology Type: Office (Business) Location: SANFORD, SEMINOLE COUNTY, FL (691500) (WEA File: Orlando.TM Lighting Controls Compliance Acronym Ashrae ID Descriation Area (sq.ft) No. of Design Min Compli- Tasks CP CP ance Zn 1 Sp 1 46 Storage & Warehouse - Fine 3,088 2 3 3 PASSES Active Storage Zone 2 Spaces 26 Offices (Partitions>4.5 ft below 5,000 1 6 6 PASSES ceiling) Enclosed offices, all open plan offices without partitions F--PASSES 1/4/2006 EnergyGauge FlaCom FLCCSB v1.22 Project: Adapco Title: Adapco Solutions & Technology Type: Office (Business) Location: SANFORD, SEMINOLE COUNTY, FL (691500) (WEA File: Orlando TM System Report Compliance Zone 1 Zone 1System Constant Volume Packaged No. of Units System I Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled 65000 to 135000 11.00 8.90 8.30 8.30 PASSES Btu/h Cooling Capacity Air Handling Air Handler (Supply) - 0.80 0.80 PASSES System -Supply Constant Volume Zone 2 Sys Zone 2 System 1 Constant Volume Packaged No. of Units 1 System I Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled 65000 to 135000 11.00 8.90 8.30 8.30 PASSES Btu/h Cooling Capacity Air Handling Air Handler (Supply) - 0.80 0.80 PASSES System -Supply Constant Volume Zone 2 Sys Zone 2 System 2 Constant Volume Air Cooled No. of Units 2 Split System < 65000 Btu/hr 4 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled < 65000 Btu/h 11.00 10.00 8.00 PASSES Cooling Capacity Air Handling Air Handler (Supply) - 0.80 0.80 PASSES System -Supply Constant Volume PASSES Plant Compliance Description Installed Size Design Min Design No Eff Eff IPLV Min Category Comp IPLV liance None 1/4/2006 EnergyGauge F1aCom FLCCSB v1.22 Project: Adapco Title: Adapco Solutions & Technology Type: Office (Business) Location: SANFORD, SEMINOLE COUNTY, FL (691500) (WEA File: Orlando.TM Water Heater Compliance Design Min Design Max Comp Description Type Category Eff Eff Loss Loss liance Water Heater 1 Storage Water Heater - <=120 [gal] & <= 0.88 0.88 PASSES Electric 12 [kW] PASSES Piping System Compliance Category Pipe Din Is Operating Ins Cond Ins Req Ins Compliance [inches] Runout? Temp [Btu-in/hr Thick ]in] Thick [in] [F] .SF.F] �— None 1/4/2006 EnergyGauge FlaCom FLCCSB vI.22 6 Project: Adapco Title: Adapco Solutions & Technology Type: Office (Business) Location: SANFORD, S Other Required Compliance Category Section Requirement (write N/A in boa if not applicable) Check Infiltration 406.1 Infiltration Criteria have been met System 407.1 HVAC Load sizing has been performed Ventilation 409.1 Ventilation criteria have been met ADS 410.1 Duct sizing and Design have been performed ❑ T & B 410.1 Testing and Balancing will be performed Electrical 413.1 Metering criteria have been met Motors 414.1 Motor efficiency criteria have been met Lighting 415.1 Lighting criteria have been met 0 & M 102.1 Operation/maintenance manual will be provided to owner Roof/Ceil 404.1 R-19 for Roof Deck with supply plenums beneath it Report 101 Input Report Print -Out from EnergyGauge FlaCom attached? El 1 /4/2006 EnergyGauge FlaCom FLCCSB v1.22 7 ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs EnergyGauge FlaCom v1.22 INPUT DATA REPORT Project Name: Adapco Project Title: Adapco Solutions & Technology Address: 550 Aero Lane Proiect Information Orientation: North Building Type: Office (Business) Building Classificatio New Finished building No.of Storeys: 1 State: FL Zip: 32771 GrossArea: 8088 Owner: Adapco, Inc. Zones No Acronym Description Type Load Profile Area Multiplier Total Area lsfl [sfl 1 Zone 1 Zone 1 CONDITIONED Uses Building Load 3088.0 1 3088.0 ❑ Profile 2 Zone 2 Zone 2 CONDITIONED Uses Building Load 5000.0 1 5000.0 ❑ Profile 1/4/2006 EnergyGauge FlaCom FLCCSB v1.22 1 Spaces No Acronym Description Type Depth Width Height Multi Total Area Total Volume IN IN [ft] plier [sf] [cf] In Zone: Zone 1 1 Zn 1 SO Zone 1 Space i Storage & Warehouse - Fine 38.60 80.00 10.00 1 3088.0 30880.0 Active Storage In Zone: Zone 2 1 Zone 2 Svaces Zone 2 Spaces Offices (Partitions>4.5 ft 100.00 50.00 10.00 1 5000.0 50000.0 El below ceiling) Enclosed offices, all open plan offices without partitions Lighting No Type Power Control Type No.of [W] Ctrl pts In Zone: Zone 1 In Space: Zn 1 Spl 1 Recessed Fluorescent - No vent 3000.00 Manual On/Off 3 In Zone: Zone 2 In Space: Zone 2 Spaces 1 Recessed Fluorescent - No vent 8850.00 Manual On/Off 6 Walls No Description Type Width H (Effec) Multi Area DirectionConductance Heat Dens. R-Value IN [ft] plier [sf] [Btu/hr. sf. F] Capacity [lb/cf] [h.sf.F/Btu] [Btu/sf.F] In Zone: Zone 1 1 Zone 1 North Wall 0.5 Ply/35/8" Mtl 80.00 10.00 1 800.0 North 0.0444 1.0088 8.59 22.54 std@24"oc/R19/0.5" Gyp 1/4/2006 EnergyGauge F1aCom FLCCSB v1.22 2 Zone 1 South Wall 8"CMU/3/4"ISO 80.00 10.00 1 800.0 North 0.2642 9.6960 62.72 3.79 BTWN24"oc/5/8 Gyp 3 Zone I East Wall Partition wall, 0.75 38.60 10.00 1 386.0 North 0.8350 2.5000 100.00 1.20 in. gyp, airspace, 0.75 in. g 4 Zone 1 West Wall 8"CMU/3/4"ISO 38.60 10.00 1 386.0 North 0.2642 9.6960 62.72 3.79 BTWN24"oc/5/8 Gyp In Zone: Zone 2 1 Zone 2 North Wall 0.75 in. stucco, 50.00 10.00 1 500.0 North 0.1118 1.1829 14.94 8.94 2x4x16" oc, RI 113att, 0.5 in. gyp 2 Zone 2 South Wall 0.75 in. stucco, 50.00 10.00 1 500.0 North 0.1118 1.1829 14.94 8.94 2x4x 16" oc, RI 1Batt, 0.5 in. gyp 3 Zone 2 East Wall 0.75 in. stucco, 100.00 10.00 1 1000.0 North 0.1118 1.1829 14.94 8.94 2x4xl6" oc, RI lBatt, 0.5 in. gyp Windows No Description Type Shaded UCen Sc Vis.Tr W H (Effec) Multi Total Area [Btu/hr sf F] IN [ft] plier [sf] In Zone: Zone 1 In Wall Zone 1 South Wall 1 Zone I South SINGLE CLEAR No 1.0018 0.95 0.88 4.00 4.00 6 96.0 Windows 1/4/2006 EnergyGauge FlaCom FLCCSB v1.22 In Zone: Zone 2 In Wail Zone 2 East Wall 1 Zone 2 East Wall SINGLE CLEAR No 1.0018 0.95 0.88 4.00 4.00 6 96.0 ❑ Windows 2 Zone 2 East Wall SINGLE CLEAR No 1.0018 0.95 0.88 3.00 7.00 1 21.0 ❑ Glass Door 3 Zone 2 East Wall SINGLE CLEAR No 1.0018 0.95 0.88 3.00 7.00 2 42.0 ❑ Sidelites In Wall Zone 2 North Wall 1 Zone 2 North SINGLE CLEAR No 1.0018 0.95 0.88 4.00 4.00 5 80.0 ❑ Windows 2 Zone 2 North SINGLE CLEAR No 1.0018 0.95 0.88 4.00 5.00 5 100.0 ❑ Windows In Wall Zone 2 South Wall 1 Zone 2 South SINGLE CLEAR No 1.0018 0.95 0.88 4.00 4.00 5 80.0 ❑ Windows 2 Zone 2 South SINGLE CLEAR No 1.0018 0.95 0.88 4.00 5.00 6 120.0 ❑ Windows 3 Zone 2 South SINGLE CLEAR No 1.0018 0.95 0.88 3.00 7.00 1 21.0 ❑ Glass Door Doors No Description Type Shaded? Width H (Effec) Multi Area Cond. Dens. Heat Cap. R-Value IN [ftl plier [sfl [Btuthr. sE F} [lb/cfl [Btu/sf. Fl [h.sEF/Btul In Zone: Zone 1 In Wall: Zone 1 North Wall 1 Zone I North Do Polystyrene core No 3.00 8.00 2 24.0 0.4982 0.00 0.00 2.01 ❑ (18 ga steel) 1 2 Zone 1 North Do Polystyrene core No 3.00 7.00 3 21.0 0.4982 0.00 0.00 2.01 ❑ (18 ga steel) 1 In Wall: Zone I East Wall I Zone 1 East Door Polystyrene core No 3.00 7.00 1 21.0 0.4982 0.00 0.00 2.01 ❑ (18 ga steel) 1 2 Zone 1 East Door Solid core flush No 3.00 7.00 1 21.0 0.6061 0.00 0.00 1.65 ❑ (1.75") In Zone: Zone 2 In Wall: Zone 2 North Wall I Zone 2 North Do Polystyrene core No 3.00 8.00 2 24.0 0.4982 0.00 0.00 2.01 ❑ (18 ga steel) 1 1/4/2006 EnergyGauge FlaCom FLCCSB v1.22 2 Zone 2 North Do Polystyrene core No 3.00 7.06 1 21.0 0.4982 0.00 0.00 2.01 ❑ (18 ga steel) 1 Roofs No Description Type Width H (Effec) Multi Area Tilt Cond. Heat Cap Dens. R-Value IN IN plier [sn [deg] [Btu/hr. Sf. Fl [Btu/sf. Fl [lb/cfl [h.sf.F/Btu) In Zone: Zone 2 ❑ 1 Roof Md Bldg Roof/R-19 160.00 100.00 1 16000.0 0.00 0.0492 1.34 9.49 20.34 Batt Skylights No Description Type UCen Shading Vis.Tran W H (Effec) Multiolier Area Total Area [Btu/hr sf F] Coeff [ft] Vt] [Sf] [Sf] In Zone: In Roof: Floors No Description Type Width H (Effec) Multi Area Cond. Heat Cap. Dens. R-Value IN [ft] plier [sfJ [Btu/hr. sf. F] [Btu/sf. Fl [lb/cf] [h.sf.F/Btul In Zone: Zone 2 ❑ 1 Floor Concrete floor, 160.00 100.00 1 16000.0 0.5987 9.33 140.00 1.67 carpet and rubber pad Systems 1/4/2006 EnergyGauge FlaCom FLCCSB v1.22 Zone 1 Zone 1System Constant Volume Packaged System No. Of Units 1 Component Category Capacity Efficiency IPLV 1 2 Cooling System (Air Cooled 65000 to 135000 Btu/h Cooling Capacity) Air Handling System -Supply (Air Handler (Supply) - Constant Volume) 81750.00 11.00 1500.00 0.80 8.30 ❑ ❑ Zone 2 Sys 1 Zone 2 System 1 Constant Volume Packaged System No. Of Units 1 Component Category Capacity Efficiency IPLV 1 2 Cooling System (Air Cooled 65000 to 135000 Btu/h Cooling Capacity) Air Handling System -Supply (Air Handler (Supply) - Constant Volume) 81750.00 11.00 1500.100 0.80 8.30 ❑ ❑ Zone 2 Sys 2 Zone 2 System 2 Constant Volume Air Cooled Split System < 65000 Btu/hr No. Of Units 4 Component Category Capacity Efficiency IPLV 1 2 Cooling System (Air Cooled < 65000 Btu/h Cooling Capacity) Air Handling System -Supply (Air Handler (Supply) - Constant Volume) 54500.00 11.00 1500.00 0.80 8.00 ❑ ❑ Plant Equipment Category Size Inst.No Eff. IPLV Water Heaters W-Heater Description Capacit Cap.Unit UP Rt. Efficienc Loss 1 Storage Water Heater - Electric 40 Gal [M] 0.8800 [EF] [%/hr] ❑ 1/4/2006 EnergyGauge FlaCom FLCCSB v1.22 Ext-Lighting Description Categories. LL-1 Area/Len/No. of units [sf/ft/No] Wattage [W] Ext Light 1 Exit (with or without Canopy) 7.00 150.00 ❑ Piping No Type Operating Insulation Temperature Conductivity [Fj [ Btu-In/h.sf.F] Nomonal pipe Diameter [in] Insulation Is Runout? Thickness [in] Fenestration Used Name Glass Type No. of Glass Conductance SC VLT Frame Frame Conductance Absorptance Panes [Btu/h.sf.F] [Btu/h.sf.FJ ApLbWnd1 SINGLE CLEAR 1 1.0018 0.9500 0.8810 0.4340 0.7000 ❑ Materials Used Only R-Value RValue Thickness Conductivity Density SpecificHea Mat No Acronym Description Used [h.sf.F/Btu] A [Btu/h.ft.F[ [Ib/cf] t 18 Mad18 2 in. Wood No 2.3857 0.1670 0.0700 37.00 0.3900 0 264 Mat1264 ALUMINUM, 1/16IN No 0.0002 0.0050 26.0000 480.00 0.1000 0 214 Mat1214 POLYSTYRENE, EXP., No 5.2100 0.1042 0.0200 1.80 0.2900 ❑ 187 Mat1187 1-1/4IN, GYP OR PLAS No 0.4533 0.0417 0.0920 50.00 0.2000 El BOARD,1 /2IN 1/4/2006 EnergyGauge FlaCom FLCCSB v1.22 206 Mat1206 CELLULOSE,FILL,5.5IN,R- No 20.8318 0.4583 0.0220 3.00 0.3300 ❑ 151 Matt 151 20 CONC HW, DRD, 140LB, No 0.4403 0.3333 0.7570 140.00 0.2000 ❑ 41N 178 Matt 178 CARPET W/RUBBER PAD Yes 1.2300 ❑ 265 Mat1265 Soil, I ft No 2.0000 1.0000 0.5000 100.00 0.2000 ❑ 48 Matl48 6 in. Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000 ❑ 123 Matt 123 CONC BLOCK No 1.7227 0.6667 0.3870 53.00 0.2000 ❑ MW,8IN,HOLLOW 159 Mat1159 CONC No 0.3202 0.3333 1.0410 140.00 0.2000 ❑ HW-UNDRD-140LB-4IN 57 Mat157 3/4 in. Plaster or gypsum No 0.1488 0.0625 0.4200 100.00 0.2000 ❑ 72 Matl72 AIR LAYER, 3/4IN OR Yes 0.9000 ❑ LESS, VERT. WALLS 267 Matl267 0.75" stucco No 0.1563 0.0625 0.4000 16.00 0.2000 El 266 Mat1266 2x4@16" oc + RI 1 Batt No 8.3343 0.2917 0.0350 9.70 0.2000 ❑ 215 Mat1215 POLYSTYRENE, EXP., No 8.3350 0.1667 0.0200 1.80 0.2900 ❑ 105 Matl105 2IN, CONC BLK HW, SIN, No 1.1002 0.6667 0.6060 69.00 0.2000 ❑ HOLLOW 256 Mat1256 WOOD, SOFT, 1-1/21N No 1.8939 0.1250 0.0660 32.00 0.3300 ❑ 268 Mat1268 0.625" stucco No 0.1302 0.0521 0.4000 16.00 0.2000 ❑ 42 Mat142 8 in. Lightweight concrete No 2.0212 0.6670 0.3300 38.00 0.2000 ❑ block 269 Mat1269 .75" ISO BTWN24" oc No 2.2321 0.0625 0.0280 4.19 0.3000 ❑ 86 Mat186 BRICK, COMMON, 4IN No 0.8012 0.3333 0.4160 120.00 0.2000 ❑ 211 Matl211 POLYSTYRENE,EXP.,1/2I No 2.0850 0.0417 0.0200 1.80 0.2900 ❑ 12 Matt 12 N, 3 in. Insulation No 10.0000 0.2500 0.0250 2.00 0.2000 ❑ 218 Mat1218 POLYURETHANE,EXP.,1/2 No 3.2077 0.0417 0.0130 1.50 0.3800 ❑ 23 Matl23 IN, 6 in. Insulation No 20.0000 0.5000 0.0250 5.70 0.2000 ❑ 4 Mat14 Steel siding No 0.0002 0.0050 26.0000 480.00 0.1000 ❑ 271 Mat1271 2x4@24" oc + RI I Batt No 10.4179 0.2917 0.0280 7.11 0.2000 ❑ 272 Mat1272 Panel with 7/16" panels Yes 0.9044 ❑ 273 Mat1273 Hollow core flush (1.375") Yes 1.2777 ❑ 274 Mat1274 Solid core flush (1.375") Yes 1.7141 ❑ 275 Mat1275 Panel with 7/16" panels Yes 1.0019 ❑ (1.375") 1/4/2006 EnergyGauge FlaCom FLCCSB v1.22 8 276 Mat1276 Hollow core flush (1.75") Yes 1.3239 ❑ 277 Mat1277 Panel with 1-1/8" panels Yes 1.7141 ❑ (1.75") 278 Mat1278 Solid core flush (1.75") Yes 1.6500 ❑ 279 Mat1279 Solid core flush (2.25") Yes 2.8537 ❑ 280 Mat1280 Fiberglass/Mineral wool core Yes 0.8167 ❑ 281 Mat1281 Paper Honeycomb core Yes 0.9357 ❑ 282 Mat1282 Solid Urethane foam core Yes 1.6500 ❑ 283 Matl283 Solid mineral fiberboard core Yes 1.7816 ❑ 284 Mat1284 Polystyrene core (18 ga steel) Yes 2.0071 ❑ 285 Mat1285 1 Polyurethane core (18 ga Yes 2.5983 ❑ steel) 2 286 Mat1286 Polyurethane core (24 ga Yes 2.5983 ❑ steel) 1 287 Mat1287 Polyurethane core (24 ga Yes 4.1500 ❑ steel) 2 ❑ 288 Mat1288 Solid Urethane foam core Yes 4.1500 81 Matl81 ASPHALT -ROOFING, Yes 0.1500 ❑ 244 Matl244 ROLL PLYWOOD, 1/2IN No 0.6318 0.0417 0.0660 34.00 0.2900 ❑ 185 Mat1185 CLAY TILE, PAVER, 3/81N No 0.0301 0.0313 1.0410 120.00 0.2000 ❑ 82 Mat182 ASPHALT -SHINGLE AND Yes 0.4400 ❑ SIDING El 11 Matl11 2 in. Insulation No 6.6800 0.1670 0.0250 2.00 0.2000 47 Matl47 2 in. Heavyweight concrete No 0.1670 0.1670 1.0000 140.00 0.2000 ❑ 95 Mat195 CONC BLOCK No 0.7107 0.3333 0.4690 101.00 0.2000 ❑ HW-41N-HOLLO W 248 Matl248 ROOF GRAVEL OR No 0.0500 0.0417 0.8340 55.00 0.4000 ❑ SLAG1/2IN 94 Matl94 BUILT-UP ROOFING, No 0.3366 0.0313 0.0930 70.00 0.3500 ❑ 3/81N Constructs Used 1/4/2006 EnergyGauge FlaCom FLCCSB v1.22 9 Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sf.Fl [Btu/sf.F] [Ib/cf[ [h.sf.F/Btu[ 1004 Concrete floor, carpet and rubber pad No No 0.60 9.33 140.00 1.6703 ❑ Layer Material Material Thickness Framing No. IN Factor 1 151 CONC HW, DRD, 140LB, 41N 0.3333 0.00 ❑ 2 178 CARPET W/RUBBER PAD 0.00 ❑ Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sEF] [Btu/sf.F] [Ib/cf] [h.sf.F/Btu] 1008 Partition wall, 0.75 in. gyp, airspace, 0.75 in. No gyp No 0.83 2.50 100.00 1.1976 ❑ Layer Material Material Thickness Framing No. IN Factor 1 57 3/4 in. Plaster or gypsum 0.0625 0.00 ❑ 2 72 AIR LAYER, 3/4IN OR LESS, VERT. 0.00 ❑ WALLS 3 57 3/4 in. Plaster or gypsum 0.0625 0.00 ❑ Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sf.F] [Btu/sEF] [Ib/cf] [h.sf.F/Btu] 1009 0.75 in. stucco, 2x4x16" oc, RI IBatt, 0.5 in. No No 0.11 1.18 14.94 8.9438 ❑ gyp Layer Material Material Thickness Framing No. IN Factor 1 267 0.75" stucco 0.0625 0.00 ❑ 2 266 2x4@ 16" oc + RI 1 Batt 0.2917 0.00 ❑ 3 187 GYP OR PLAS BOARD,1/2IN 0.0417 0.00 ❑ 1/4/2006 EnergyGauge FlaCom FLCCSB vI.22 10 Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sf.F] [Btu/sEF] [ib/cf] [h.sf.F/Btu[ 1014 8"CMU/3/4"ISO BTWN24"oc/5/8 Gyp No No 0.26 9.70 62.72 3.7856 ❑ Layer Material Material Thickness Framing No. IN Factor 1 105 CONC BLK HW, 81N, HOLLOW 0.6667 0.00 ❑ 2 269 .75" ISO BTWN24" oc 0.0625 0.00 ❑ 3 187 GYP OR PLAS BOARD,1/2IN 0.0417 0.00 ❑ Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sf.F] [Btu/sEF] [Ib/cf) [h.sEFBtu] 1017 0.5 Ply/35/8" Mtl std@24"oc/R19/0.5" Gyp No No 0.04 1.01 8.59 22.5383 ❑ Layer Material Material Thickness Framing No. IN Factor 1 211 POLYSTYRENE,EXP.,1/2IN, 0.0417 0.00 ❑ 2 23 6 in. Insulation 0.5000 0.00 ❑ 3 187 GYP OR PLAS BOARD,1/21N 0.0417 0.00 ❑ Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sEF) [Btu/sf.F] [ib/cf] [h.sf.F/Btu] 1027 Solid core flush (1.75") No Yes 0.61 1.6500 ❑ 1/4/2006 Layer Material Material Thickness Framing No. IN Factor 1 278 Solid core flush (1.75") 0.00 ❑ EnergyGauge FiaCom FLCCSB v1.22 11 Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.F/Btu] 1033 Polystyrene core (18 ga steel) I No Yes 0.50 2.0071 ❑ Layer Material Material Thickness Framing No. IN Factor 1 284 Polystyrene core (18 ga steel) 1 0.00 ❑ Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.F/Btu] 1047 Mtl Bldg Roof/R-19 Batt No No 0.05 1.34 9.49 20.3366 ❑ Layer Material Material Thickness Framing No. IN Factor 1 94 BUILT-UP ROOFING, 3/81N 0.0313 0.00 ❑ 2 23 6 in. Insulation 0.5000 0.00 ❑ 1/4/2006 EnergyGauge F1aCom FLCCSB v1.22 12