HomeMy WebLinkAbout113 Bellagio CirSANFOA FIRE DEPARTMENT
FIRE PREVENTION DIVISION
300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl.
32772
(407) 302-1091 / FAX (407) 302-2625
F_ D
Plans Review Sheet
Date: 8/03/07 Business Address: 113 Bellagio circle #30 Occ. Business
Business Name: The Fountain Market Place Ph. (407)264-0100
Contractor: ADT security Fax (407)712-1813
Reviewed [ ] Reviewed with comment [ x]; Rejected [ ]
Reviewed by: Orlando Nunez, Fire Inspector/Plans Examiner
Comment:
1.1 Application — The following items submitted for permitting
1.2 Will need to submit approved sprinkler plans.
Please call (407) 302-10221nspector James for fire inspections 48 notice required on all inspections.
1
E
PROJECT SUMMARY
Short Desc:
Tennant Suite # 30
Description:
Tennant Suite # 30
Owner:
Addressl:
113 Bellagio Circle
City:
Sanford
Address2:
State:
Florida
Zip:
32771
Type:
Office
Class:
Renovation to existing
Jurisdiction:
SANFORD, SEMINOLE COUNTY, FL (691500)
Cond Area:
2518 SF
Cond & UnCond Area:
2518 SF
No of Storeys:
2
Area entered from Plans
2518 SF
Permit No:
0
Max Tonnage
6
If different, write in:
Compliance Summary
Component Design Criteria Result
Gross Energy Use 1,890.5 2,463.2 PASSE
LIGHTING CONTROLS
EXTERNAL LIGHTING
HVAC SYSTEM
PLANT
WATER HEATING SYSTEMS
PIPING SYSTEMS
Met all required compliance from Check List?
PASSES
PASSE
PASSES
None Entered
None Entered
None Entered
Yes o/NA
IMPORTANT NOTE: An input report of this design building must be submitted
along with this Compliance Report.
7/19/2007 EnergyGauge FLA/COM 2004 v3.00 2
CERTIFICATIONS
I hereby certify that the plans a d specifications covered by this calculation are in compliance with the
Florida Energy Code
Prepared By: Building Official:
Dat : Date:
I certify that this building is in compliance with the FLorida Energy Efficiency Code
Owner Agent: Date:
If Required by Florida law, I hereby certify (*) that th y ign i in compliance with the FLorida
Energy Efficiency Code
Architect: Reg No: to
Electrical Designer: Reg No:
Lighting Designer Reg No:
A
Mechanical Designer: � ) ey! to/ Reg No: COOK I& S 3 0
Plumbing Designer: Reg No:
{*) Signature is required where Florida Law requires design to be performed by registered design
professionals. Typed names and registration numbers may be used where all relevant information is
contained on signed/sealed plans.
nergyGauge Summit v3.90 incorporating Florida Energy Code Version - FLA/COM 2004 v2.E 3
Project: Tennant Suite # 30
Title: Tennant Suite # 30
Type: Office
(WEA File: Orlando.TMY)
Whole Building Compliance
Design
Reference
Total
75.13
100.00
$1,890
$2,463
ELECTRICITY(MBtu/k
75.13
100.00
Whl$)
36996
49263
$1,890
$2,463
AREA LIGHTS
21.30
15.88
10498
7826
$536
$391
MISC EQUIPMT
8.63
8.63
4234
4234
$216
$212
PUMPS & MISC
0.12
0.12
63
64
$3
$3
SPACE COOL
28.49
24.15
14035
11908
$717
$595
VENT FANS
16.60
51.22
8166
25231
$417
$1,262
Credits & Penalties (if any): Modified Points: = 75.14
PASSES
7/19/2007 EnergyGauge FLA/COM 2004 v3.00
Project: Tennant Suite # 30
Title: Tennant Suite # 30
Type: Office
(WEA File:.Orlando.TMY)
External Lighting Compliance
Description
Category Allowance Area or Length ELPA CLP
(W/Unit) or No. of Units (W) (W)
(Sgft or ft)
Ext Light 1
Other (doors) than main entries 20.00 18.0 360 100
Design: 300 (W)
PASSES
Allowance: 360 (W)
Project: Tennant Suite # 30
Title: Tennant Suite # 30
Type: Office
(WEA File: Orlando.TMY)
Lighting Controls Compliance
Acronym Ashrae
Description
Area
No. of Design Min Compli-
ID
(sq.ft)
Tasks CP CP ance
Toilet 6
Toilet and Washroom
57
1 1 1 PASSES
Open Work Area 16
Office - Open Plan
1,847
1 2 1 PASSES
Mezzanine Storage 3
Storage & Warehouse - Bulky
522
1 l 1 PASSES
Active Storage
Stair 4
Stair - Active Traffic
92
1 1 1 PASSES
PASSES
7/19/2007 EnergyGauge FLA/COM 2004 v3.00
Project: Tennant Suite # 30
Title: Tennant Suite # 30
Type: Office
(WEA File: Orlando.TMY)
System Report Compliance
RTU-1 System 1
Constant Volume Packaged No. of Units
System
I
Component Category
Capacity Design Eff Design IPLV
Comp-
Eff Criteria IPLV Criteria
liance
Cooling System Air Cooled 65000 to 135000
13.00 10.30 13.00
PASSES
Btu/h Cooling Capacity
Air Handling Air Handler (Supply) -
0.31 0.90
PASSES
System -Supply Constant Volume
RTU-2 System 2
Constant Volume Air Cooled No. of Units
Single Package System <
65000 Rtu/hr
1
Component Category
Capacity Design Eff Design IPLV
Comp-
Eff Criteria IPLV Criteria
liance
Cooling System Air Cooled < 65000 Btu/h
13.00 13.00 13.00
PASSES
Cooling Capacity
Air Handling Air Handler (Supply) -
0.23 0.90
PASSES
System -Supply Constant Volume
PASSES j
Plant Compliance
Description Installed Size Design
Min Design Min Category
Comp
No Eff
Eff IPLV IPLV
liance
None
Water Heater Compliance
Description Type Category Design Min Design Max Comp
Eff Eff Loss Loss liance
None
7/19/2007 EnergyGauge FLA/COM 2004 v3.00
Piping System Compliance
Category
Pipe Dia Is Operating Ins Cond Ins Req Ins
Compliance
[inches] Runout? Temp [Btu-in/hr Thick [in] Thick [in]
[F] SF.F]
None
Project: Tennant Suite # 30
Title: Tennant Suite
# 30
Type: Office
(WEA File: Orlando.TMY)
Other Required Compliance
Category
Section
Requirement (write N/A in box if not applicable)
Check
Infiltration
406.1
Infiltration Criteria have been met
System
407.1
HVAC Load sizing has been performed
1_J
Ventilation
409.1
Ventilation criteria have been met
ADS
410.1
Duct sizing and Design have been performed
T & B
410.1
Testing and Balancing will be performed
L:J
Motors
414.1
Motor efficiency criteria have been met
�.
Lighting
415.1
Lighting criteria have been met
O & M
102.1
Operation/maintenance manual will be provided to owner
Roof/Ceil
404.1
R-19 for Roof Deck with supply plenums beneath it
Report
101
Input Report Print -Out from EnergyGauge F1aCom attached?
7/19/2007 EnergyGauge FLA/COM 2004 v3.00
EnergyGauge FLAXOM 2004 v3.00
INPUT DATA REPORT
Proiect Information
Project Name:
Tennant Suite # 30
Orientation:
East
Project Title:
Tennant Suite # 30
Building Type:
Office
Address:
113 Bellagio Circle
Building Classification:
Renovation to existing building
State: Florida No.of Storeys: 2
Zip: 32771 GrossArea: 2518 SF
Owner:
Zones
No Acronym Description Type Area Multiplier Total Area
[stl [stl
1 1 St Floor Zone 1 CONDITIONED 1903.6 1 1903.6 ❑
2 2 nd Floor Zone 2 CONDITIONED 614.0 1 614.0 ❑
7/19/2007 EnergyGauge FLA/COM 2004 Q.00 1
Spaces
No Acronym Description
Type
Depth
Width
Height
Multi Total Area
Total Volume
[ft]
[ft]
[ft]
plier [sf]
[cf]
In Zone: 1 St Floor
1 Toilet Zo0Sp2
Toilet and Washroom
8.50
6.66
9.00
1 56.6
509.5
El
2 Open Work ArZo0Sp6
Office - Open Plan
71.98
25.66
9.00
1 1847.0
16623.1
E]
In Zone: 2 nd Floor
1 Mezzanine StoZo0Sp1
Storage & Warehouse -
20.34
25.66
8.00
1 522.0
4175.8
[l
Bulky Active Storage
2 Stair Zo0Sp3
Stair - Active Traffic
11.00
8.36
22.00
1 92.0
2023.8
Lighting
No Type
Category
No. of
Watts per
Power
Control Type
No.of
Luminaires
Luminaire
[W]
Ctrl pts
In Zone: 1 St Floor
In Space: Toilet
1 Compact Fluorescent
General Lighting
2
34
68
Manual On/Off
1
In Space: Open Work Area
1 Recessed Fluorescent
- General Lighting
20
128
2560
Manual On/Off
2
No vent
In Zone: 2 nd Floor
In Space: Mezzanine Storage
1 Recessed Fluorescent
- General Lighting
6
128
768
Manual On/Off
1
El
No vent
In Space: Stair
1 Suspended Fluorescent General Lighting
1
32
32
Manual On/Off
1
[�
7/19/2007 EnergyGauge FLA/COM 2004 v3.00
Walls -
No Description
Type
Width H (Effec) Multi Area DirectionConductance
Heat
Dens. R-Value
IN IN plier [sf]
[Btu/hr. sf. F]
Capacity
[lb/cf] [h.sf.F/Btu]
[Btu/sf.F]
In Zone: 1 St Floor
1 PrOZo1Wal
Concrete Tilt Wall
25.66 12.00 1 307.9
East 0.3139
14.496
119.74 3.2
❑
w/ .75"ins./GypBd
2 PrOZo1Wa3
Concrete Tilt Wall
12.00 22.00 1 264.0
West 0.3139
14.496
119.74 3.2
❑
w/ .75"ins./GypBd
3 PrOZo1Wa4
Partition wall, 0.75
32.00 22.00 1 704.0
North 0.8350
2.500
100.00 1.2
❑
in. gyp, airspace,
0.75 in. gyp
In Zone: 2 nd Floor
1 PrOZo2Wa1
Concrete Tilt Wall
25.66 11.00 1 282.3
East 0.3139
14.496
119.74 3.2
❑
w/ .75"ins./GypBd
2 PrOZo2Wa2
Partition wall, 0.75
25.66 11.00 1 282.3
North 0.8350
2.500
100.00 1.2
❑
in. gyp, airspace,
0.75 in. gyp
Windows
No Description Type
Shaded U SHGC Vis.Tra
W H (Effec)
Multi
Total Area
[Btu/hr sf F]
IN [ft]
plier
[sf]
In Zone: 1 St Floor
In Wall: East
1 PrOZo1Wa1Wi1
UserDefined
No 1.2500 0.82 0.76
4.66 8.00
2
74.6
❑
2 PrOZo1Wa1Wi2
UserDefined
No 1.2500 0.82_ 0.76
6.00 8.00
1
48.0
❑
In Zone: 2 nd Floor
In Wall: East
1 PrOZo2WalWi1 UserDefined
No 1.2500 0.82 0.76
4.66 4.66
3
65.1
❑
Doors
No Description
Type
Shaded? Width H (Effec) Multi
Area Cond.
Dens. Heat Cap. R-Value
IN [ft] plier
[sf] [Btu/hr. sE F]
[lb/cf] [Btu/sE F] [h.sf.FBtu]
7/19/2007 EnergyGauge FLA/COM 2004 v3.00
In Zone: 1 St Floor
In Wall: West
1 PrOZo1Wa3Dr1 Hollow core flush
No
10.00 12.00
1
120.0
0.7553 0.00
0.00
1.32
❑
In Zone: 2 nd Floor
In Wall: Partition
1 PrOZo2Wa2Drl Solid core flush
No
3.00 6.66
1
20.0
0.3504 0.00
0.00
2.85
❑
(2.25)
Roofs
No Description Type
Width
H (Effec) Multi
Area
Tilt
Cond. Heat Cap
Dens.
R-Value
[ft]
IN plier
[sfJ
[deg] [Btu/hr. SC F] [Btu/sf. F] [lb/cf]
[h.sf.FBtu]
In Zone: 1 St Floor
1 PrOZo1Rfl Mtl Bldg Roof/R-19
25.66
49.47 1
1269.5
0.00
0.0492 1.34
9.49
20.3
❑
Batt
In Zone: 2 nd Floor
1 PrOZo2Rfl Mtl Bldg Roof/R-19
25.66
24.32 1
624.0
0.00
0.0492 1.34
9.49
20.3
❑
Batt
Skylights
No Description Type
U SHGC Vis.Trans
W
H (Effec) Multiplier
Area
Total Area
[Btu/hr sf F]
IN
IN
[sf]
[Sf]
In Zone:
In Roof:
a
Floors
No Description Type
Width
H (Effec) Multi
Area
Cond.
Heat Cap. Dens.
R-Value
[ft]
[ft] plier
[sf]
[Btu/hr. sf. F] [Btu/st F] [lb/cf]
[b.sf.FBtu]
In Zone: 1 St Floor
7/19/2007 EnergyGauge FLA/COM 2004 v3.00
I Pr0Zo1Fll 1 ft. soil, concrete 25.66 70.21 1 1801.5 0.1745 54.00 108.00 5.73 ❑
floor, carpet and
rubber pad
Systems
RTU-1
System 1
Constant Volume Packaged System No. Of Units 1
Component
Category
Capacity Efficiency IPLV
1
2
Cooling System (Air Cooled 65000 to 135000 Btu/h
Cooling Capacity)
Air Handling System -Supply (Air Handler (Supply) -
Constant Volume)
72000.00 13.00 13.00
2400.00 0.31
❑
❑
RTU-2
System 2
Constant Volume Air Cooled Single No. Of Units 1
Package System < 65000 Btu/hr
Component
Category
Capacity Efficiency IPLV
1
2
Cooling System (Air Cooled < 65000 Btu/h Cooling
Capacity)
Air Handling System -Supply (Air Handler (Supply) -
Constant Volume)
24000.00 1.3.00 13.00
800.00 0.23
❑
❑
Plant
Equipment Category
Size Inst.No Eff. IPLV
LJ
Water Heaters
W-Heater Description Capacit3Cap.Unit
I/P Rt. Efficiency Loss
7/1.9/2007 EnergyGauge FLA/COM 2004 v3.00 5
Ext-Lighting
Description Category No. of Watts per Area/Len/No. of units
Luminaires Luminaire [sf/ft/No]
Control Type Wattage
[W]
1 Ext Light 1 Other (doors) than main 3 100
entries
18.00 Astronomical Timer Coi 300.00 ❑
Piping
No Type Operating Insulation
Temperature Conductivity
[F] ] Btu-in/h.sf.F]
Nomonal pipe
Diameter
[in]
Insulation Is Runout?
Thickness
[in]
El
Fenestration Used
Name
Glass Type No. of
Glass Conductance SHGC VLT
Panes
[Btu/h.sf.F] _
ASHULSg1ClrAll
User Defined 1
1.2500 0.8200 0:7600
[�
Frm
Materials Used
Mat No Acronym
Description
Only R-Value RValue Thickness
Conductivity
Density
SpecificHeat
Used [h.sf.FBtu] [ft]
[Btu/h.ft.F]
[lb/cf]
[Btu/lb.F]
187 Mat1187
GYP OR PLAS
No 0.4533 0.0417
0.0920
50.00
0.2000 ❑
BOARD,1 /21N
178 Mat1178
CARPET W/RUBBER PAD
Yes 1.2300
❑
265 Mat1265
Soil, 1 ft
No 2.0000 1.0000
0.5000
100.00
0.2000 ❑
7/19/2007
EnergyGauge FLA/COM 2004 v3.00
6
48
Mat148
6.in. Heavyweight concrete
No
0.5000
0.5000
1.0000
140.00
0.2000
❑
57
Matl57
3/4 in. Plaster or gypsum
No
0.1488
0.0625
0.4200
100.00
0.2000
❑
72
Mat172
AIR LAYER, 3/41N OR
Yes
0.9000
❑
LESS, VERT. WALLS
269
Mat1269
.75" ISO BTWN24" oc
No
2.2321
0.0625
0.0280
4.19
0.3000
❑
23
Matl23
6 in. Insulation
No
20.0000
0.5000
0.0250
5.70
0.2000
❑
94
Mat194
BUILT-UP ROOFING,
No
0.3366
0.031.3
0.0930
70.00
0.3500
❑
3/81N
Constructs Used
No
Name
Simple
Massless
Conductance
Heat Capacity
Density
RValue
Construct
Construct
[Btu/h.sEF]
[Btu/sf.F]
[lb/cf]
[h.sf.FBtu]
1008
Partition wall, 0.75 in. gyp, airspace, 0.75 in. No
No
0.83
2.50
100.00
1.2
❑
gyp
Layer
Material
Material
Thickness Framing
No.
[ft]
Factor
1
57
3/4 in. Plaster or gypsum
0.0625
0.000
❑
2
72
AIR LAYER, 3/41N OR LESS, VERT.
0.000
WALLS
3
57
3/4 in. Plaster or gypsum
0.0625
0.000
❑
No
Name
Simple
Massless
Conductance
Heat Capacity
Density
RValue
Construct
Construct
Btu/h.sf.F [ )
[Btu/sf.F]
[Ib/cfJ
[hsf.FBtu]
1025
Hollow core flush
No
Yes
0.76
1.3
❑
Layer Material Material Thickness Framing
No. IN Factor
1 276 Hollow core flush (1.75") 0.000
7/19/2007 EnergyGauge FLA/COM 2004 v3.00 7
No Name
Simple
Massless Conductance Heat Capacity
Density
RValue
Construct
Construct [Btu/h.sf.F]
[Btu/sf.F]
[lb/cf]
[h.sf.FBtu]
1047 Mtl Bldg Roof/R-19 Batt
No
No 0.05
1.34
9.49
20.3
❑
Layer
Material
Material
Thickness
Framing
No.
[ft]
Factor
1
94
BUILT-UP ROOFING, 3/81N
0.0313
0.000
❑
2
23
6 in. Insulation
0.5000
0.000
❑
No Name
Simple
Massless Conductance Heat Capacity
Density
RValue
Construct
Construct [Btu/h.sf.F]
[Btu/sf.F]
[lb/cf]
[h.sf.F/]Btu]
1056 Concrete Tilt Wall w/ .75"ins./GypBd No
No 0.31
14.50
119.74
3.2
❑ __
Layer
Material
Material
Thickness
Framing
No.
[ft]
Factor
1
48
6 in. Heavyweight concrete
0.5000
0.000
❑
2
269
.75" ISO BTWN24" oc
0.0625
0.000
❑
3
187
GYP OR PLAS BOARD,1/21N
0.0417
0.000
❑
No Name
Simple
Massless Conductance Heat Capacity
Density
RValue
Construct
Construct [Btu/h.sf.F]
[Btu/sf.F]
[lb/cf]
[h.sf.F/Btu]
1057 1 ft. soil, concrete floor, carpet and rubber pad No
No 0.17
54.00
108.00
5.7
❑
Layer
Material
Material
Thickness
Framing
No.
[ft]
Factor
1
265
Soil, 1 ft
2.0000
0.000
❑
2
48
6 in. Heavyweight concrete
0.5000
0.000
❑
3
178
CARPET W/RUBBER PAD
0.000
❑
7/19/2007 EnergyGauge FLA/COM 2004 v3.00 8
No
Name
Simple
Massless Conductance Heat Capacity
Density
RValue
Construct
Construct [Btu/h.sLF] [Btu/sLF]
[lb/cf]
[h.sLF/Btu]
1058
Solid core flush
(2.25)
No
Yes 0.35
2.9
❑
Layer
Material
Material
Thickness Framing
No.
[ft] Factor
1
279
Solid core flush (2.25")
0.000
❑
No
Name
Simple
Massless Conductance Heat Capacity
Density
RValue
Construct
Construct [Btu/h.sf.F] [Btu/sf.F]
[lb/cf]
[h.sf.FBtu]
1059
Partition wall, 0.75
in. gyp, airspace,
0.75 in. No
No 0.83 2.50
100.00
1.2
❑
gyp
Layer
Material.
Material
Thickness Framing
No.
[ft] Factor
1
57
3/4 in. Plaster or gypsum
0.0625 0.000
❑
2
72
AIR LAYER, 3/41N OR LESS, VERT. 0.000
❑
WALLS
3
57
3/4 in. Plaster or gypsum
0.0625 0.000
❑
7/1.9/2007 EnergyGauge FLA/COM 2004 v3.00 9