Loading...
HomeMy WebLinkAbout1141 W Aiport BlvdFlorida Energy Efficiency Code For Building Construction Florida Department of Community Affairs EnergyGauge F1aCom v 2.11 FORM 40OA-2004 Whole Building Performance Method for Commercial Buildings Jurisdiction: SANFORD, SEMINOLE COUNTY, FL (691500) Short Desc: BRIOBLDG#2 Project: BRIO BUILDING #2 - TENANT Owner: Address: 1141 WEST AIRPORT BLVD BRIO COMMERCE CENTER BUILDING #2 City: SANFORD State: FL PermitNo: 0-- Zip: 0 Storeys: 1 Type: Office *Conditioned Area: 560 * denotes lighted Class: Renovation to existing building *Cond + UnCond Area: 560 area. Does not include wall crosection areas Max Tonnage: 3.0 (if different, write in) 11 Compliance Summary 11 Component Design Criteria Result Gross Energy Use 604.95 792.03 PASSES LIGHTING CONTROLS EXTERNAL LIGHTING HVAC SYSTEM PLANT WATER HEATING SYSTEMS PIPING SYSTEMS Met all required compliance from Check List? PASSES None Entered PASSES None Entered PASSES None Entered Yes/No/NA IMPORTANT NOTE: An input report Print -Out from EnergyGauge Com of this design building must be submitted along with this Compliance Report. 3/8/2006 EnergyGauge FlaCom v 2.11 FORM 40OA-2004 COMPLIANCE CER'11F1CA'I'ION: I hereby certify that the plans and Review of the plans and specifications covered by this specifications covered by this calculation are calculation indicates compliance with the Florida Energy in compliance with the Florida Ener y Code. Before construction is completed, this building will be Efficiency Code. inspected for compliance in accordance with Section 553.908, F.S. PREPARED BY: GUS BOBES JR P.E. BUILDING OFFICIAL: DATE: Yr gk DATE: I hereby certify that this building is in compliance with the Florida Energy Efficiency Code. OWNER AGENT: DATE: If required by Florida law, I hereby certify (') that the system design is in REGISTRATION compliance with the Florida Energy Code. No. ARCHITECT: ELECTRICAL SYSTEM DESIGNER: LIGHTING SYSTEM DESIGNER: MECHANICAL SYSTEM DESIGNER: PLUMBING SYSTEM DESIGNER: (') Signature is required where Florida Law requires design to be performed by registered design professionals. Typed names and registration numbers may be used where all relevant information is contained on signed/sealed plans. 3/8/2006 EnergyGauge F1aCom v 2.11 FORM 40OA-2004 2 Project: BRIOBLDG#2 Title: BRIO BUILDING #2 - TENANT Type: Office (WEA File: Orlando.TMY) Whole Building Compliance Total Design 75.50 $604.95 Reference 100.00 $792.03 ELECTRICITY(MBtu/kWh/$ 75.50 100.00 12,099.00 16,033.00 $604.95 $792.03 AREA LIGHTS 12.25 11.70 1,960.00 1,886.00 $98.00 $93.17 MISC EQUIPMT 7.68 7.68 1,231.00 1,231.00 $61.55 $60.81 PUMPS & MISC 0.18 0.18 17.00 31.00 $0.85 $1.53 SPACE COOL 25.96 21.39 4,160.00 3,424.00 $208.00 $169.15 VENT FANS 29.43 59.05 4,731.00 9,461.00 $236.55 $467.37 Credits & Penalties (if any): Modified Points: = 75.51 PASSES External Lighting Compliance Description Category Allowance Area or Length ELPA CLP (W/Unit) or No. of Units (W) (W) (Sgft or ft) None 3/8/2006 EnergyGauge FlaCom v 2.11 FORM 40OA-2004 3 Project: BRIOBLDG#2 Title: BRIO BUILDING #2 - TENANT Type: Office (WEA File: Orlando.TMY) Lighting Controls Compliance Acronym Ashrae Description ID Area No. of Design Min Compli- (sq.ft) Tasks CP CP ance Pr0Zo1Sp1 16 Office - Open Plan 560 1 2 1 PASSES PASSES Project: BRIOBLDG#2 Title: BRIO BUILDING #2 - TENANT Type: Office (WEA File: Orlando.TMY) System Report Compliance PrOSyl System 1 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled < 65000 Btu/h Cooling Capacity Air Handling Air Handler (Supply) - System -Supply Constant Volume 13.00 10.00 13.00 PASSES 0.45 0.90 PASSES PASSES Plant Compliance Description Installed Size Design No Eff Min Design Min Category_ Comp Eff IPLV IPLV liance None 3/8/2006 EnergyGauge FlaCom v 2.11 FORM 40OA-2004 Project: BRIOBLDG#2 Title: BRIO BUILDING #2 - TENANT Type: Office (WEA File: Orlando.TMY) Water Neater Compliance Description Type Category Design Min Design Max Comp Eff Eff Loss Loss liance Water Heater I Electric water heater > 12 [kW] 0.85 0.02 267.41 PASSES PASSES Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance [inches] Runout? . Temp [Btu-in/hr Thick [in] Thick [in] [F] SF.F] None 3/8/2006 EnergyGauge FlaCom v 2.11 FORM 400A-2004 Project: BRIOBLDG#2 Title: BRIO BUILDING #2 - TENANT Type: Office (WEA File: Orlando.TMY) Other Required Compliance Category Section Requirement (write N/A in box if not applicable) Check Infiltration 406.1 Infiltration Criteria have been met System 407.1 HVAC Load sizing has been performed Ventilation 409.1 Ventilation criteria have been met ADS 410.1 Duct sizing and Design have. been performed T & B 410.1 Testing and Balancing will be performed Motors 414.1 Motor efficiency criteria have been met Lighting 415.1 Lighting criteria have been met O & M 102.1 Operation/maintenance manual will be provided to owner Roof/Ceil 404.1 R-19 for Roof Deck with supply plenums beneath it Report 101 Input Report Print -Out from EnergyGauge FlaCom attached? ❑ 3/8/2006 EnergyGauge FlaCom v 2.11 FORM 40OA-2004 6 EnergyGauge F1aCom v 2.11 INPUT DATA REPORT Proiect Information Project Name: BRIOBLDG#2 Orientation: North Project Title: BRIO BUILDING #2 - TENANT BuildingType: Yp Office Address: 1137 WEST AIRPORT BLVD Building Classification: Renovation to existing building BRIO COMMERCE CENTER BUILDING #2 State: FL No.of Storeys: I Zip: 0 GrossArea: 560 Owner: Zones No Acronym Description Type Area Multiplier Total Area 1 PrOZoI Zone 1 CONDITIONED [sfl [sfJ 560.0 1 560.0 ❑ Spaces No Acronym Description Type Depth Width Height Multi Total Area Total Volume [ft] IN [ft] plier lsfl I lef] 3/8/2006 EnergyGauge FlaCom v 2.11 1 In Zone: PrOZol 1 PrOZolsol ZoOSpl Office - Open Plan 28.00 20.00 9.00 1 560.0 5040.0 El Lighting No Type Category No. of Watts per Power Control Type No.of Luminaires Luminaire [W] Ctrl pts In Zone: PrOZol In Space: PrOZo1Sp1 1 Recessed Fluorescent - General Lighting No 1 640 640 Manual On/Off 2 ventEJ Walls No Description Type Width H (Effec) Multi Area DirectionConductance Heat Dens. R-Value [ft] [ft] plier [sf] [Btu/hr. sf. F] Capacity [lb/cf] [h.sf.FBtu] [Btu/sf.F] In Zone: PrOZol 1 PrOZo1Wal 0.5 Ply/35/8" Mtl 20.00 10.00 1 200.0 North 0.0798 0.5388 7.98 12.54 std@24"oc/R 11 /0.5" Gyp 2 PrOZo 1 Wa2 Metal 20.00 12.00 1 240.0 South 0.0957 0.7570 16.80 10.45 siding/R11 Batt/0.5" Gyp Windows No Description Type Shaded U SHG Vis.Tr W H (Effec) Multi Total Area [Btu/hr sf F] [ft] [ft] plier [sf] In Zone: PrOZol In Wall: Pr0Zo1Wa2 1 PrOZo1Wa2Wil SINGLE CLEAR No 1.0018 0.81 0.88 17.00 4.00 2 136.0 El 3/8/2006 EnergyGauge F1aCom v 2.11 2 Doors No Description Type Shaded? Width H (Effec) Multi Area Cond. Dens. Heat Cap. R-Value IN [ft] plier [sfJ [Btu/hr. sf. F] [lb/cf] [Btu/sf. F] [h-sf.F/Btu] In Zone: In Wall: Roofs No Description Type Width H (Effec) Multi Area Tilt Cond. Heat Cap Dens. R-Value IN IN plier [sf] [deg] [Btu/hr. Sf. F] [Btu/sf. F] [lb/cf] [h.sf.FBtu] In Zone: PrOZol 1 PrOZo1Rf1 Mtl Bldg Roof/R-19 Batt 20.00 28.00 1 560.0 0.00 0.0492 1.34 9.49 20.34 ❑ Skylights No Description Type U SHGC Vis.Trans W H (Effec) Multiplier Area Total Area [Btu/hr sf F1 [ft] [ft] [Sf] [Sf] In Zone: In Roof: Floors No Description Type Width H(Effec) Multi Area Cond. Heat Cap. Dens. R-Value IN IN plier [sf] [Btu/hr. sf. F] [Btu/sf. F] [lb/cf] [h.sf.F/Btu] In Zone: PrOZol 1 PrOZo 1 F11 Concrete floor, 20.00 28.00 1 560.0 0.5987 9.33 140.00 1.67 ❑ carpet and rubber pad 3/8/2006 EnergyGauge F1aCom v 2.11 3 PrOSyl System 1 ►vent Category 1 Cooling System (Air Cooled < 65000 Btu/h Cooling Capacity) 2 Air Handling System -Supply (Air Handler (Supply) - Constant Volume) Systems Constant Volume Air Cooled Split System < 65000 Btu/hr Capacity Efficiency IPLV 36000.00 13.00 13.00 1200.00 0.45 No. Of Units 1 3/8/2006 } EnergyGauge F1aCom v 2.11 4 I Fenestration Used Name Glass Type No. of Glass SHGC VLT Panes Conductance [Btu/h.sf.Fl ApLbWndl SINGLE CLEAR 1 1.0018 0.8150 0.8810 ❑ Materials Used Mat No Acronym Description Only R-Value RValue Thickness Conductivity Density SpecificHeat Used [h.sf.FBtu] [ft] [Btu/h.ft.Fl [lb/cf] [Btu/Ib.F] 187 Mat1187 GYP OR PLAS No 0.4533 0.0417 0.0920 50.00 0.2000 ❑ BOARD,1 /2IN 151 Matll51 CONC HW, DRD, 140LB, No 0.4403 0.3333 0.7570 140.00 0.2000 ❑ 41N 178 Matl178 CARPET W/RUBBER PAD Yes 1.2300 ❑ 211 Matl211 POLYSTYRENE,EXP.,1/2I No 2.0850 0.0417 0.0200 1.80 0.2900 ❑ N, 12 Matl12 3 in. Insulation No 10.0000 0.2500 0.0250 2.00 0.2000 ❑ 23 Matl23 6 in. Insulation No 20.0000 0.5000 0.0250 5.70 0.2000 ❑ 4 Mat14 Steel siding No 0.0002 0.0050 26.0000 480.00 0.1000 ❑ IL 94 Mat194 BUILT-UP ROOFING, No 0.3366 0.0313 0.0930 70.00 0.3500 ❑ 3/8IN Constructs Used 3/8/2006 EnergyGauge FlaCom v 2.11 5 No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.FBtu] 1004 Concrete floor, carpet and rubber pad No No 0.60 9.33 140.00 1.6703 ❑ Layer Material Material Thickness Framing No. IN Factor 1 151 CONC HW, DRD, 140LB, 41N 0.3333 0.00 ❑ 2 178 CARPET W/RUBBER PAD 0.00 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sLF] [Btu/sf.F] [lb/cf] [h.sLFBtu] 1015 0.5 Ply/35/8" Mtl std@24"oc/R11/0.5" Gyp No No 0.08 0.54 7.98 12.5383 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 211 POLYSTYRENE,EXP.,1/2IN, 0.0417 0.00 ❑ 2 12 3 in. Insulation 0.2500 0.00 ❑ 3 187 GYP OR PLAS BOARD,1/2IN 0.0417 0.00 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [Ib/cf] [h.sLF/Btu] 1020 Metal siding/RI I Batt/0. 5 "Gyp No No 0.10 0.76 16.80 10.4535 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 4 Steel siding 0.0050 0.00 ❑ 2 12 3 in. Insulation 0.2500 0.00 ❑ 3 187 GYP OR PLAS BOARD,1/2IN 0.0417 0.00 ❑ 3/8/2006 EnergyGauge F1aCom v 2.11 6 t No Name 1047 Mtl Bldg Roof/R-19 Batt Layer Material Material No. Simple Massless Construct Construct No No 1 94 BUILT-UP ROOFING, 3/81N 2 23 6 in. Insulation Conductance [Btu/h.sLF] Heat Capacity [Btu/sf.F] Density [lb/cf] RValue [h.sf.FBtu] 0.05 1.34 9.49 20.3366 ❑ Thickness Framing IN Factor 0.0313 0.00 ❑ 0.5000 0.00 ❑ 3/8/2006 EnergyGauge FlaCom v 2.11 W