Loading...
HomeMy WebLinkAbout1165 W Airport Blvd (3)E ,S s SANFORD FIRE DEPARTMENT FIRE PREVENTIONDIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, FI. 32772 (407 302-2516 / FAX (407) 302-2526 Fire Marshal Plans Review Sheet Date: October 9, 2006 Business Address: 1165 W. Airport Blvd. Occ. Ch. 40 Industrial- 38-Business Business Name: Prostalund PH (407) 830-1414 Fax. (407) 830-8448 Architect: JRJJ & Associates PH (407) 875-0115 Fax. (407) 875-0308 Comment: Plans reviewed as Occ. Ch. 40 Industrial-38-Business Type IV fire sprinkler protected 2,093sq ft type IV fire sprinkled building Occupancy's FD reserves right to require applicable code requirements if occupancy use changes. Sprinkler plans to be submitted for review, permitting, and inspections. Sealed letter from Engineer of Record stating design criteria for sprinkler system needs to be submitted with construction plans. F Fire Alarm Requirement: See below Fire Alarm notification: Each individual tenant space shall have two (2) horn strobes, for individual tenant notification (one in business office, and one in storage/industrial area). - Application — New Building (2,093 s. q. ft.) 1 T SANFORD FIRE DEPARTMENT , FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, FI. 32771 / P. O. Box 1788, Sanford, FI. 32772 (407 302-2516 / FAX (407) 302-2526 Fire Marshal 1.1 1.2 1.3 Mixed — N/A, 2.3 Capacity of Egress — sales floor area based on one (])_person per 30 sq ft., storage area based on one (1) person per 300 sq. ft. 2.4 Number of Exits — two for each individual tenant ok 2.5 Arrangement of Egress O.K. — two for each individual tenant ok 2.6 Travel Distance — 2.7 Discharge from Exits — O.K., will field verify 2.8 Illumination of Means of Egress —additional EXIT SIGNS may be required (power shut down test required at night only) 2.9 Emergency Lighting — (1) foot candle (10 Ix & a minimum at any point of 0.1 foot-candle (1LX ) measured along the path of egress at floor level.Therfore additional emergency lights may be required, (power shut down test required at night only) Emergency Lights required In all rest rooms & Main Electrical Room (*). 2.10 Marking of Means of Egress — O.K.; will field verify 2.11 Special Features —Reserved 3.1 Protection of Vertical Openings — Ch. 40 Industrial-38-Business 3.2 Protection from Hazards — (See exception 40-3.2.1 .LSC 101) 3.3 Interior Finish — Not required, building has an automatic fire sprinkler system 3.4 Detection, Alarm and Communications System: (as per N.F.PA.72- 3-8.3.1.2 (99) Ed. 2 SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, FI. 32771 / P. O. Box 1788, Sanford, FI. 32772 (407 302-2516 / FAX (407) 302-2526 Fire Marshal • 3.5 Extinguishing Requirements — as per NFPA 10, one (1) 2A 10 BC rated fire extinguishers required per N.F.PA. #10 (see blueprints for locations). 5.1 Utilities — as per LSC 7-1 5.2 HVAC — as per LSC 7-2 5.3 Elevators, Escalators, Conveyors (4A-47) — N/A Sanford City Code — Chapter9: Required; Fire Sprinklers. Drop fire sprinkler heads below ceiling Monitoring: Required on all fire sprinkler valves (includes inside and out) Other: NFPA 1 3-5.1 Fire Lanes — Required (see sight plan) 3-6.1 Key Box— required already 3-7.1 Bldg. Address Number Posted and Legible — Post address in 6" Six inch numbers contrasting in color (see blue prints). 3 Florida Energy Efficiency Code For Building Construction Florida Department of Community Affairs EnergyGauge F1aCom v 2.11 FORM 40OA-2004 Whole Building Performance Method for Commercial Buildings Jurisdiction: SANFORD, SEMINOLE COUNTY, FL (691500) Short Desc: PROSTALUND Project: PROSTALUND, INC. Owner: Address: 1165 WEST AIRPORT BLVD City: SANFORD State: FL PermitNo: 0-- Zip: 0 Storeys: 1 Type: Office *Conditioned Area: 1163 Class: Renovation to existing building *Cond + UnCond Area: 1163 Max Tonnage: 3.5 (if different, write in) Compliance Summary * denotes lighted area. Does not include wall crosection areas Component Design Criteria Result Gross Energy Use 1,352.85 1,801.17 PASSES LIGHTING CONTROLS EXTERNAL LIGHTING HVAC SYSTEM PLANT WATER HEATING SYSTEMS PIPING SYSTEMS Met all required compliance from Check List? PASSES None Entered PASSES None Entered PASSES None Entered Yes/No/NA IMPORTANT NOTE: An input report Print -Out from EnergyGauge Co of this design building must be submitted along with this Compliance Report. 9/14/2006 EnergyGauge FlaCom v 2.11 FORM 40OA-2004 I MWAVIA WA I LIMIA I hereby certify that the plans and specifications covered by this calculation'arp, in compliance with the Florida- Enemy Efficiency Code.'. PREPARED BY:- GUS BOBES JR P.E. DATE: I hereby certify that this building is in'compliiancr with the Florida Energy Efficiency Code. Review of the plans and specifications covered by this calculation indicates compliance with the Florida .Energy Code. Before construction is completed, this building will be inspected for compliance in accordance with Section 553.908, F.S. BUILDING OFFICIAL: DATE: OWNER AGENT; DATE: If required by Florida law, I hereby certify (*) that the system design is in REGISTRATION compliance with the Florida Energy Code. No. ARCHITECT: ELECTRICAL SYSTEM DESIGNER: LIGHTING SYSTEM DESIGNER: MECHANICAL SYSTEM DESIGNER: PLUMBING SYSTEM DESIGNER: (*) Signature is required where Florida Law requires design to be performed by registered design professionals. Typed names and registration numbers may be used where all relevant information is contained on signed/sealed plans. 9/14/2006 EnergyGauge FlaCom v 2.11 FORM 40OA-2004 2 Project: PROSTALUND Title: PROSTALUND, INC. Type: Office (WEA File: Orlando.TMY) Whole Building Compliance Design Reference Total 74.20 100.00 $1,352.85 $1,801.17 ELECTRICITY(MBtu/kWh/$ 74.20 100.00 27,057.00 36,461.00 $1,352.85 $1,801.17 AREA LIGHTS 10.05 10.77 3,675.00 3,916.00 $183.75 $193.45 MISC EQUIPMT 6.99 6.99 2,555.00 2,555.00 $127. 75 $126 22 PUMPS & MISC 0.08 0.08 28.00 31.00 $1.40 $1.53 SPACE COOL 26.77 21.62 9,763.00 7,886.00 $488.15 $389.57 VENT FANS 30.31 60.53 11,036.00 22,073.00 $551.80 $1, 090.41 Credits & Penalties (if any): Modified Points: = 74.2 PASSES External Lighting Compliance Description Category Allowance Area or Length ELPA CLP (W/Unit) or No. of Units (W) (W) (Sgft or ft) None 9/ 14/2006 EnergyGauge FlaCom v 2.11 FORM 40OA-2004 3 Project: PROSTALUND Title: PROSTALUND, INC. Type: Office (WEA File: Orlando.TMY) Lighting Controls Compliance. Acronym Ashrae Description Area No. of Design Min Compli- ID (sq.ft) Tasks CP CP ance PrOZo 1 Sp 1 17 Office - Enclosed 1,163 1 4 1 PASSES II PASSES II Project: PROSTALUND Title: PROSTALUND, INC. Type: Office (WEA File: Orlando.TMV) System Report Compliance PrOSyl System 1 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 2 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled < 65000 Btu/h 13.00 10.00 13.00 PASSES Cooling Capacity Air Handling Air Handler (Supply) - 0.45 0.90 PASSES System -Supply Constant Volume PASSES Plant Compliance Description Installed Size Design Min Design Min Category Comp No Eff Eff IPLV IPLV liance None 9/14/2006 EnergyGauge FlaCom v 2.11 FORM 40OA-2004 4 Project: PROSTALUND Title: PROSTALUND, INC. Type: Office (WEA File: Orlando.TMY) Water Heater Compliance Description Type Category Design Min Design Max Comp Eff Eff Loss Loss liance Water Heater 1 Electric water heater > 12 [kW] 0.85 0.02 267.41 PASSES PASSES Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance [inches] Runout? Temp [Btu-in/hr Thick [in] Thick [in] [F] SF.FJ None 9/14/2006 EnergyGauge FlaCom v 2.11 FORM 400A-2004 Project: PROSTALUND Title: PROSTALUND, INC. Type: Office (WEA File: Orlando.TMY) Other Required Compliance Category Section Requirement (write N/A in box if not applicable) Check Infiltration 406.1 Infiltration Criteria have been met System 407.1 HVAC Load sizing has been performed Ventilation 409.1 Ventilation criteria have been met ADS 410.1 Duct sizing and Design have been performed ED T & B 410.1 Testing and Balancing will be performed Motors 414.1 Motor efficiency criteria have been met Lighting 415.1 Lighting criteria have been met O & M 102.1 Operation/maintenance manual will be provided to owner Roof/Ceil 404.1 R-19 for Roof Deck with supply plenums beneath it Report 101 Input Report Print -Out from EnergyGauge FlaCom attached? El 9/14/2006 EnergyGauge F1aCom v 2.11 FORM 40OA-2004 6 EnergyGauge F1aCom v 2.11 INPUT DATA REPORT Project Information Project Name: PROSTALUND Orientation: North Project Title: PROSTALUND, INC. Building Type: Office Address: 1165 WEST AIRPORT BLVD Building Classification: Renovation to existing building State: FL Zip: 0 Owner: No.of Storeys: l GrossArea: '1163 Zones No Acronym Description Type Area Multiplier Total Area 1 PrOZol Zone 1 CONDITIONED [Sl1 1162.5 [sl7 1 1162.5 Spaces No Acronym Description Type Depth Width Height Multi Total Area Total Volume lft] [ft] lft] plier lsf] 1cfl 9/14/2006 EnergyGauge FlaCom v 2.11 1 In Zone: PrOZol 1 Pr0ZolSvI Zo0Sp1 Office - Enclosed 37.50 31.00 11.50 1 1162.5 13368.8 Lighting No Type Category No. of Watts per Power Control Type No.of Luminaires Luminaire [W] Ctrl pts In Zone: PrOZol In Space: Pr0Zo1Sp1 1 Recessed Fluorescent - General Lighting 1 600 600 Manual On/Off 2 El No vent 2 Recessed Fluorescent - General Lighting 1 600 600 Manual On/Off 2 No vent Walls No Description Type Width H (Effec) Multi Area DirectionConductance Heat Dens. R-Value IN [ft] plier [sf] [Btu/hr. sf. F] Capacity [lb/cfl [h.sLFBtu] [Btu/sLF] In Zone: PrOZol I PrOZOI WaI Metal 31.00 12.00 1 372.0 East 0.0957 0.7570 16.80 10.45 siding/R11 Batt/0.5" Gyp 2 Pr0ZOIWa3 0.5 Ply/35/8" Mtl 48.00 12.00 1 576.0 West 0.0798 0.5388 7.98 12.54 std@24"oc/R 11 /0.5' Gyp Windows No Description Type Shaded U SHG Vis.Tr W H (Effec) Multi Total Area [Btu/hr sf F] [ft] [ft] plier [sf] In Zone: PrOZol In Wall: PrOZo1Wal 1 PrOZolWalWi1 SINGLE CLEAR No 1.0018 0.81 0.88 22.00 8.00 2 352.0 9/14/2006 . EnergyGauge FlaCom v 2.11 Doors No Description Type Shaded? Width H (Effec) Multi Area Cond. Dens. Heat Cap. R-Value IN IN plier [sf] [Btu/hr. sf. F] [lb/cf] [Btu/sf. F] [h.sf.F/Btu] In Zone: PrOZol In Wall: PrOZo1Wa3 1 PrOZolWa3Drl Wood door, 2 in. No 3.00 7.00 1 21.0 0.4192 37.00 2.41 2.39 ❑ Roofs No Description Type Width H (Effec) Multi Area Tilt Cond. Heat Cap Dens. R-Value . [ft] [ft] plier [sf] [deg] [Btu/hr. Sf. F] [Btu/sf. F] [lb/cf] [h.sf.F/Btu] In Zone: PrOZol 1 PrOZo1Rfl Mtl Bldg Roof/R-19 31.00 37.50 1 1162.5 0.00 0.0492 1.34 9.49 20.34 ❑ Batt Skylights No Description Type U SHGC Vis.Trans W H (Effec) Multiplier Area Total Area [Btu/hr sf F] IN A [sf] [Sf] In Zone: In Roof: Floors No Description Type Width H (Effec) Multi Area Cond. Heat Cap. Dens. R-Value IN [ft] plier [sf] [Btu/hr. sL F] [Btu/sL F] [Ib/cf] [h.sLFBtu] In Zone: PrOZol 1 PrOZolFll Concrete floor, 31.00 37.50 1 1162.5 0.5987 9.33 140.00 1.67 ❑ carpet and rubber pad 9/14/2006 EnergyGauge F1aCom v 2.11 Systems PrOSyI System 1 Constant Volume Air Cooled Split System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System (Air Cooled < 65000 Btu/h Cooling 42000.00 1100 13.00 Capacity) 2 Air Handling System -Supply (Air Handler (Supply) - 1400.00 0.45 Constant Volume) Plant Equipment Category Size Inst.No Eff. Water Heaters No. Of Units 2 IPLV W-Heater Description Capacit Cap.Unit UP Rt. Efficienc Loss 1 Electric water heater 50 [Gal] ] 16382 [kW] 0.8500 [Ef] 0.0200 [Btulh] Ext-Lighting Description Category No. of Watts per Area/Len/No. of units Control Type Wattage Luminaires Luminaire [sf/ft/No] [w] No . Type - Piping Operating Insulation Temperature Conductivity [F] [ Btu-in/h.sf.F] Nomonal pipe Insulation Is Runout? Diameter Thickness [►n] [inl 9/14/2006 EnergyGauge FlaCom v 2.11 4 0 M Fenestration Used Name Glass Type No. of Glass SHGC VLT Panes Conductance [Btu/h.sf.F] ApLbWndl SINGLE CLEAR 1 1.0018 0.8150 0.8810 ❑ Materials Used Mat No Acronym Description Only R-Value RValue Thickness Conductivity Density SpecificHeat Used [h.sf.F/Btu] IN [Btu/h.ft.F ] [Ib/cf] [Btu/Ib.F] 18 Mat118 2 in. Wood No 2.3857 0.1670 0.0700 37.00 0.3900 - ❑ 187 Mat1187 GYP OR PLAS No 0.4533 0.0417 0.0920 50.00 0.2000 ❑ BOARD,1 /21N 151 Mad151 CONC HW, DRD, 140LB, No 0.4403 0.3333 0.7570 140.00 0.2000 ❑ 41N 178 Mat1178 CARPET W/RUBBER PAD Yes 1.2300 ❑ 211 Mat12ll POLYSTYRENE,EXP.,1/2I No 2.0850 0.0417 0.0200 1.80 0.2900 ❑ N, 12 Mat112 3 in. Insulation No 10.0000 0.2500 0.0250 2.00 0.2000 ❑ 23 Matl23 6 in. Insulation No 20.0000 0.5000 0.0250 5.70 0.2000 ❑ 4 Mat14 Steel siding . No 0.0002 0.0050 26.0000 480.00 0.1000 ❑ 94 Mat194 BUILT-UP. ROOFING, No 0.3366 0.0313 0.0930 70.00 0.3500 ❑ 3/81N Constructs Used 9/14/2006 EnergyGauge FlaCom v 2.11 No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sLF] [Btu/sf.F] [lb/cf] [h.sLF/Btu] 1001 Wood door, 2 in. No No 0.42 2.41 37.00 2.3857 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 18 2 in. Wood 0.1670 0.00 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sLF] [Btu/sf.F] [lb/cf] [h.sLFBtu] 1004 Concrete floor, carpet and rubber pad No No 0.60 9.33 140.00 1.6703 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 151 CONC HW, DRD, 140LB, 4IN 0.3333 0.00 ❑ 2 178 CARPET W/RUBBER PAD 0.00 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sLF] [Btu/sf.F] [lb/cf] [h.sLFBtu] 1015 0.5 Ply/35/8" Mtl std@24"oc/R11/0.5" Gyp No No 0.08 6.54 7.98 12.5383 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 211 POLYSTYRENE,EXP.,1/2IN, 0.0417 0.00 ❑ 2 12 3 in. Insulation 0.2500 0.00 ❑ 3 187 GYP OR PLAS BOARD,1/21N 0.0417 0.00 ❑ 9/14/2006 EnergyGauge F1aCom v 2.11 6 No 1020 Name Metal siding/RI I Batt/0. 5 "Gyp Simple Construct No Massless Construct No Conductance [Btu/h.sf.F] 0.10 Layer Material Material Thickness No. IN1 4 Steel siding 0.0050 2 12 3 in. Insulation 0.2500 3 187 GYP OR PLAS BOARD,1/21N 0.0417 No Name Simple Massless Conductance Construct Construct [Btu/h.sf.F] 1047 Mtl Bldg Roof/R-19 Batt No No 0.05 9/14/2006 Layer Material Material Thickness No. [ft] 1 94 BUILT-UP ROOFING, 3/81N 0.0313 2 23 6 in. Insulation 0.5000 EnergyGauge FlaCom v 2.11 Heat Capacity Density RValue [Btu/sf.F] [lb/cf] [h.sf.FBtu] 0.76 16.80 10.4535 ❑ Framing Factor 0.00 ❑ 0.00 ❑ 0.00 ❑ Heat Capacity Density RValue [Btu/sf.F] [lb/cf] [h.sf.FBtu] 1.34 9.49 20.3366 ❑ Framing Factor 0.00 ❑ 0.00 ❑ 7