Re: Highsteppers American Karate Studio Expansion
D3A Project No. 06072
Mr. Wayne Thomas:
The following is in response to your Architectural and Plumbing Comment dated February 13,
2007.
A-1: See revised Floor Plan Key Note 18 on Sht. A2.1 which adds the requirement for Category
II glazing.
P-1: The occupant load as listed on the plans is incorrect. Based on 50 s.f. per person (gross
s.f.) for exercise rooms, the occupant load is 126. The two Accessible Women's Toilet rooms
and the single Accessible Men's Toilet room meets the requirements based on the correct
occupant load.
If you have any questions, please do not hesitate to call me.
Since e
"LANS EWED
Mark Hansen FORD
President
Architect, ARA .
Commercial Architectural Design
DESIGN THREE ASSOCIATES - ARCHITECTS
License Number AAP000452
815 Orienta Avenue, Suite 1050
Altamonte springs, FL 32701
(407)834-2444 0 FAX: (407) 834-4922
Interior Design
Space Planning
Florida Energy Efficiency Code For Building Construction
Florida Department of Community Affairs
EnergyGauge F1aCom v 2.11 FORM 40OA-2004
Whole Building Performance Method for Commercial Buildings
Jurisdiction:
SANFORD, SEMINOLE COUNTY, FL (691500)
Short Desc:
HIGHSTEPPERS
Project:
HIGH STEPPERS AMERICAN KARATE
Owner:
STUDIO EXPANSION
Address:
1197 WEST AIRPORT BLVD
BRIO COMMERCE CENTER BUILDING #2
City:
SANFORD
State:
FL
PermitNo:
0--
Zip:
32771
Storeys:
1
Type:
Retail
*Conditioned Area: 1680 * denotes lighted
Class:
Renovation to existing building
*Cond + UnCond Area: 1680 area. Does not include
wall crosection areas
Max Tonnage:
5.6 (if different, write in)
El
11 Compliance Summary 11
Component Design Criteria Result
Gross Energy Use 2,817.90 3,505.03 PASSES
LIGHTING CONTROLS
EXTERNAL LIGHTING
HVAC SYSTEM PLANS REVIEWED
PLANT C;NTY OF SANFORD
WATER HEATING SYSTEMS
PIPING SYSTEMS
Met all required compliance from Check List?
PASSES
None Entered
PASSES
None Entered
PASSES
None Entered
Yes/No/NA
IMPORTANT NOTE: An input report Print -Out from EnergyGauge Com of
this design building must be submitted along with this Compliance Report
1/20/2007 EnergyGauge FlaCom v 2.11 FORM 40OA-2004 1
I hereby certify that the . plans and
specifications covered by this calculation are
in compliance with the Florida Energy
Efficiency Code.
PREPARED BY: GUS BOBES JR P.E.
DATE:
I hereby certify that this building is in compliance
with the Florida Energy Efficiency Code.
Review of the plans and specifications covered by this
calculation indicates compliance with the Florida Energy
Code. Before construction is completed, this building will be
inspected for compliance in accordance with Section
553.908, F.S.
BUILDING OFFICIAL:
DATE:
OWNER AGENT:
DATE:
If required by Florida law, I hereby certify (*) that the system design is in
compliance with the Florida Energy Code.
ARCHITECT:
ELECTRICAL SYSTEM DESIGNER:
LIGHTING SYSTEM DESIGNER:
MECHANICAL SYSTEM DESIGNER:
PLUMBING SYSTEM DESIGNER:
REGISTRATION
No.
(*) Signature is required where Florida Law requires design to be performed by registered design professionals.
Typed names and registration numbers may be used where all relevant information is contained on signed/sealed
plans.
1/20/2007 EnergyGauge F1aCom v 2.11 FORM 40OA-2004 2
Project: HIGHSTEPPERS
Title: HIGH STEPPERS AMERICAN KARATE STUDIO EXPANSION
Type: Retail
(WEA File: Orlando.TW)
Whole Building Compliance
II Total
Design
79.73
$2,817.90
Reference
100.00
$3,505.03
ELECTRICITY(MB AWhi$ 79.73 100.00
56,358.00 70,666.00
$2,817.90 $3,505.03
AREA LIGHTS 23.84 26.95
16,854.00 19,058.00
$842.70 $945.28
MISC EQUIPMT
15.30
15.30
10,807.00
10,807.00
$540.35
$536.03
PUMPS & MISC
0.04
0.04
23.00
23.00
$1.15
$1.14
SPACE COOL
31.26
30.93
22,104.00
21,855.00
$1,105.20
$1, 084.01
VENT FANS
9.29
26.78
6,570.00
18,923.00
$328.50
$938.58
Credits & Penalties (if any): Modified Points: = 79.73
PASSES —
External Lighting Compliance
Description Category Allowance Area or Length ELPA CLP
(W/Unit) or No. of Units (VV) (VV)
(Sgft or ft)
None —�
1/20/2007 EnergyGauge FlaCom v 2.11 FORM 40OA-2004 3
Project: HIGHSTEPPERS
Title: HIGH STEPPERS AMERICAN KARATE STUDIO EXPANSION
Type: Retail
(WEA File: Orlando.TMY)
Lighting Controls Compliance
Acronym Ashrae Description Area No. of Design Min Compli-
ID (sq.ft) Tasks CP CP ance
PrOZo1Sp1 001 General Sales Area 1,680 1 2 1 PASSES
PASSES
Project: HIGHSTEPPERS
Title: HIGH STEPPERS AMERICAN KARATE STUDIO EXPANSION
Type: Retail
(WEA File: Orlando.TMY)
System Report Compliance
PrOSyl System 1 Condensing Units No. of Units
1
Component Category Capacity Design Eff Design IPLV Comp-
Eff Criteria IPLV Criteria liance
Cooling System Air Cooled 10.50 10.10 11.20 11.20 PASSES
Air Handling Air Handler (Supply) - 0.31 0.90 PASSES
System -Supply Constant Volume
PASSES
Plant Compliance
Description Installed Size Design Min Design Min Category Comp
No Eff Eff IPLV IPLV liance
None
1/20/2007 EnergyGauge FlaCom v 2.11 FORM 40OA-2004
Project: HIGHSTEPPERS
Title: HIGH STEPPERS AMERICAN KARATE STUDIO
EXPANSION
Type: Retail
(WEA File: Orlando.TMY)
Water Heater Compliance
Description Type Category Design
Min Design Max Comp
Eff
Eff Loss Loss liance
Water Heater 1 Electric water heater > 12 [kW] 0.85
0.02 267.41 PASSES
PASSES
Piping System Compliance
Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance
[inches] Runout? Temp [Btu-in/hr Thick [in] Thick [in]
[F] SF.F]
ul
None
1/20/2007 EnergyGauge FlaCom v 2.11 FORM 400A-2004 5
Project: HIGHSTEPPERS
Title: HIGH STEPPERS AMERICAN KARATE STUDIO EXPANSION
Type: Retail
(WEA Fil
Other Required Compliance
Category
Section
Requirement (write N/A in box if not applicable)
Check
Infiltration
406.1
Infiltration Criteria have been met
System
407.1,
HVAC Load sizing has been performed
Ventilation
409.1
Ventilation criteria have been met
ADS
410.1
Duct sizing and Design have been performed
T & B
410.1
Testing and Balancing will be performed
El
Motors
414.1
Motor efficiency criteria have been met
Lighting
415.1
Lighting criteria have been met
O & M
102.1
Operation/maintenance manual will be provided to owner
Roof/Ceil
404.1
R-19 for Roof Deck with supply plenums beneath it
Report
101
Input Report Print -Out from EnergyGauge F1aCom attached?
1/20/2007 EnergyGauge FlaCom v 2.11 FORM 40OA-2004 6
EnergyGauge F1aCom v 2.11
INPUT DATA REPORT
Proiect Information
Project Name: HIGHSTEPPERS Orientation: North
Project Title: HIGH STEPPERS AMERICAN KARATE STUDIO EXPANSIO Building Type: Retail
Address: 1197 WEST AIRPORT BLVD Building Classification: Renovation to existing building
BRIO COMMERCE CENTER BUILDING #2
State: FL
Zip: 32771
Owner:
No.of Storeys: I
GrossArea: 1680
Zones
No Acronym Description Type
Area
[sfl
Multiplier
Total Area
[sf]
1 PrOZol Zone 1 CONDITIONED
1680.0
1
1680.0
Spaces
No Acronym Description Type Depth
[ft]
Width Height Multi
IN [ft] plier
Total Area
[sf]
Total Volume
[ctl
1/20/2007 EnergyGauge FlaCom v 2.11 1
In Zone: PrOZol
1 PrOZo1Sp1
ZoOSp1 General Sales Area
70.00
24.00 11.00
1
1680.0
18480.0
Lighting
No
Type Category
No. of
Watts per Power
Control Type
No.of
Luminaires
Luminaire [W]
Ctrl pts
In Zone: PrOZol
In Space: PrOZo1Spl
1
Recessed Fluorescent - General Lighting
26
120 3120
Manual On/Off
2
No vent
Walls
No Description
Type Width H (Effec) Multi Area DirectionConductance
Heat
Dens. R-Value
IN
IN plier
[sf] [Btu/hr.
sf. F]
Capacity
[lb/cf] [h.sf.F/Btu]
[Btu/sf.F]
In Zone: PrOZol
1 PrOZo1Wal
0.5 Ply/35/8" Mtl 24.00
12.00 1
288.0 SouthWes
0.0798
0.5388
7.98 12.54 ❑
std@24"oc/R11/0.5"
t
Gyp
2 PrOZo1Wa2
Metal 24.00
12.00 1
288.0 NorthEast
0.0957
0.7570
16.80 10.45
siding/R l l Batt/0.5"
Gyp
Windows
No
Description Type Shaded
U SHG
Vis.Tr W
H (Effec)
Multi
Total Area
[Btu/hr sf F]
[ft]
[ft]
plier
[sf]
In Zone: PrOZol
In Wall: Pr0Zo1Wa2
1
PrOZo1Wa2Wi1 SINGLE CLEAR No
1.0018 0.81
0.88 21.50
4.00
2
172.0
1/20/2007 EnergyGauge F1aCom v 2.11
F,
Doors
No Description
Type
Shaded? Width H (Effec) Multi
Area
Cond. Dens. Heat Cap.
R-Value
[ft] IN
plier
[sf]
[Btu/hr. sf. F] [lb/cf] [Btu/sf.
F]
[h.sf.FBtu]
In Zone: PrOZol
In Wall: PrOZolWal
1 PrOZo 1 Wa 1 Drl Aluminum door,
No
3.00 7.00
1
21.0
0.1919 43.67
0.53
5.21
1.25 in.
polystyrene
Roofs
No Description
Type
Width
H (Effec) Multi
Area
Tilt
Cond. Heat Cap
Dens.
R-Value
IN
[ft] plier
[sf]
[deg]
[Btu/hr. SE F] [Btu/sf. F]
[lb/cf]
[h.sf.F/Btu]
In Zone: PrOZol
1 PrOZo1Rfl
Mtl Bldg Roof/R-19
24.00
70.00 1
1680.0
0.00
0.0492 1.34
9.49
20.34 ❑
Batt
Skylights
No Description Type
U SHGC Vis.Trans
W
H (Effec) Multiplier
Area
Total Area
[Btu/hr sf F]
IN
[ft]
[Sf]
[Sf]
In Zone:
In Roof:
Floors
No Description
Type
Width
H (Effec) Multi
Area
Cond. Heat Cap. Dens.
R-Value
IN
IN plier
[sf]
[Btu/hr. sf. F] [Btu/sf. F] [lb/cf]
jh.sf.FBtu]
In Zone: PrOZol
1/20/2007 EnergyGauge F1aCom v 2.11
I Pr07n1R11
_., K;; I.IvvI, Ll+•UU
carpet and rubber
AM1
1680.0 0.5987
9.33 140.00
1.67
❑
pad
Systems
PrOSyl System 1
Condensing Units
No. Of Units 1
Component Category
Capacity
Efficiency
IPLV
1 Cooling System (Air Cooled)
67000.00
10.50
11.20
2 Air Handling System -Supply (Air Handler (Supply),-
2400.00
0.31
❑
Constant Volume)
❑
Plant
Equipment Category
Size
Inst.No
Eff.
IPLV
Lj
Water Heaters
W-Heater Description Capacit Cap.Unit
I/P Rt.
Efficienc
Loss
1 Electric water heater 50 [Gal]
16382 [kW]
0.8500 [Ef]
0.0200
[Btu/h]
❑
Ext-Lighting
Description Category
No. of Watts per
Area/Len/No. of units Control Type
Wattage
Luminaires Luminaire
[sf/f"01
[w]
r--- 1
u
1/20/2007 Energy'Gauge F1aCom v 2.11
Piping
No
Type
Operating Insulation
Nomonal pipe
Insulation
Is Runout?
Temperature Conductivity
Diameter
Thickness
[F] [ Btu-in/h.sf.F]
[in]
[in]
Fenestration Used
Name
Glass Type No. of
Glass SHGC VLT
Panes
Conductance
[Btu/h.sf.F]
ApLbWndl
SINGLE CLEAR 1
1.0018 0.8150 0.8810
❑
Materials Used
Mat No
Acronym
Description
Only R-Value RValue Thickness
Conductivity
Density
SpecificHeat
Used [h.sf.FBtu] [ft]
[Btu/h.ft.F]
[lb/c f]
(Btu/1b.F)
264
Mat1264
ALUMINUM, 1/16IN
No 0.0002 0.0050
26.0000
480.00
0.1000
❑
214
Mat1214
POLYSTYRENE, EXP.,
No 5.2100 0.1042
0.0200
1.80
0.2900
❑
1-1 /41N,
187
Mat1187
GYP OR PLAS
No 0.4533 0.0417
0.0920
50.00
0.2000
❑
BOARD,1 /21N
151
Mad151
CONC HW, DRD, 140LB,
No 0.4403 0.3333
0.7570
140.00
0.2000
❑
41N
178
Mat1178
CARPET W/RUBBER PAD
Yes 1.2300
❑
- 211
Matl211
POLYSTYRENE,EXP.,1/2I
No 2.0850 0.0417
0.0200
1.80
0.2900
❑
N,
12
Mad 12
3 in. Insulation
No 10.0000 0.2500
0.0250
2.00
0.2000
❑
23
Mat123
6 in. Insulation
No 20.0000 0.5000
0.0250
5.70
0.2000
❑
4
Mat14
Steel siding
No - 0.0002 0.0050
26.0000
480.00
0.1000
❑
1/20/2007 EnergyGauge FlaCom v 2.11
94 Mat194
BUILT-UP ROOFING, No
0.3366 0.0313
0.0930
70.00
0.3500
❑
3/81N
Constructs Used
No Name
Simple
Massless Conductance Heat Capacity
Density
RValue
Construct
Construct [Btu/h.sf.F]
[Btu/sf.F]
[lb/cf]
[h.sf.FBtul
1002 Aluminum door,
1.25 in. polystyrene No
No 0.19
0.53
43.67
5.2104
❑
Layer
Material
Material
Thickness
Framing
No.
IN
Factor
1
264
ALUMINUM, 1/16IN
0.0050
0.00
❑
2
214
POLYSTYRENE, EXP., 1-1/41N,
0.1042
0.00
❑
3
264
ALUMINUM, 1/16IN
0.0050
0.00
❑
No Name
Simple
Massless Conductance Heat Capacity
Density
RValue
Construct
Construct [Btu/h.sf.F]
[Btu/sf.F]
[lb/cf]
[h.sf.FBtu]
1004 Concrete floor, carpet and rubber pad No
No 0.60
9.33
140.00
1.6703
❑
Layer
Material
Material
Thickness
Framing
No.
IN
Factor
1
151
CONC HW, DRD, 140LB, 41N
0.3333
0.00
❑
2
178
CARPET W/RUBBER PAD
0.00
❑
No Name
Simple
Massless Conductance
Heat Capacity
Density
RValue
Construct
Construct [Btu/h.sf.F]
[Btu/sf.F]
[lb/cf]
[h.sLFBtul
1015 0.5 Ply/35/8"
Mtl std@24"oc/R11/0.5" Gyp No
No 0.08
0.54
7.98
12.5383
❑
Layer
Material
Material
Thickness
Framing
No.
IN
Factor
1
211
POLYSTYRENE,EXP.,1/2IN,
0.0417
0.00
❑
2
12
3 in. Insulation
0.2500
0.00
❑
3
187
GYP OR PLAS BOARD,1/21N
0.0417
0.00
❑
1/20/2007
EnergyGauge FlaCom v 2.11
6
No Name Simple
Construct
Massless
Construct
Conductance
[Btu/h.sfF]
Heat Capacity
[Btu/sfF]
Density
[lb/cf]
RValue
[h.sfFBtu]
1020 Metal siding/RI I Batt/0.5 "Gyp No
No
0.10
0.76
16.80
10.4535 ❑
Layer
Material
Material
Thickness
Framing
No.
IN
Factor
1
4
Steel siding
0.0050
0.00
❑
2
12
3 in. Insulation
0.2500
0.00
❑
3
187
GYP OR PLAS BOARD,1/2IN
0.0417
0.00
❑
No Name
Simple
Massless Conductance
Heat Capacity
Density RValue
Construct
Construct [Btu/h.sf.F]
[Btu/sfF]
[lb/cf] [h.sf.F/Btu]
1047 Mtl Bldg Roof/R-19 Batt
No
No 0.05
1.34
9.49 20.3366 ❑
Layer Material Material Thickness Framing
No. IN Factor
1 94 BUILT-UP ROOFING, 3/81N 0.0313 0.00 ❑
2 23 6 in. Insulation 0.5000 0.00
1/20/2007 EnergyGauge FlaCom v 2.11 7
City of Sanford
Building Division
300 N. Park Ave
Sanford, Florida 32771
Phone: 407-330-5656
Fax: 407-328-3859
PLAN REVIEW RESPONSE
Date: February 13, 2007
Contact Person: Mike Puryear
Contact Phone Number: 407-830-1414 Contact Fax Number: 407-830-8448
Contact E-mail Address:
Reference Number:
Project Description: Highsteppers Karate
Job Address: 1197 W. Airport Blvd.
The following is a list of the areas of the submitted plans that contained violations of the codes
adopted by the City of Sanford and enforced by the Building Division. The violations noted must
be addressed before the plans can be approved. Changes must be submitted on the original
submitted format. Changes to construction documents that require an Architect or Engineer's seal
must be submitted with the appropriate seal.
ARCHITECTURAL
A-1 The window adjacent to the door to office 102 shall be safety glazed. FBC 2406.3
PLUMBING
P-1 Based on an occupant load of 409 there are not enough restroom plumbing fixtures for
both men and women. FPC 403.1.
Any error or omission in this plan review shall not be construed to grant approval of any violation
of any of the adopted codes or municipal ordinances of this jurisdiction.
Please direct any questions you may have to Wayne Thorne at (407) 330-5686 or fax to (407)
328-3859. You may also contact me by E-mail at thornew(dci.sanford.fl.us.
-1-
,1\