Loading...
HomeMy WebLinkAbout1255 - 1259 W Aiport Blvds Florida Enertiy Efficiency Code For Building Construction Florida Department of Community Affairs EnergyGauge F1aCom v 2.11 FORM 40OA-2004 Whole Building Performance Method for Commercial Buildings Jurisdiction: SANFORD, SEMINOLE COUNTY, FL (691500) Short Desc: PRECPROTH Project: PRECISION PROSTHETICS Owner: Address: 1255 & 1259 WEST AIRPORT BLVD City: SANFORD State: FL Zip: 0 Type: Office Class: Renovation to existing building PermitNo: 0-- Storeys: 1 *Conditioned Area: 3792 * denotes lighted *Cond + UnCond Area: 3792 area. Does not include wall crosection areas Max Tonnage: 5.0 (if different, write in) Compliance Summary Component Design Criteria Result Gross Energy Use 2,641.62 3,807.41 PASSES LIGHTING CONTROLS EXTERNAL LIGHTING HVAC SYSTEM PLANT WATER HEATING SYSTEMS PIPING SYSTEMS Met all required compliance from Check List? PASSES None Entered PASSES None Entered PASSES None Entered Yes/No/NA IMPORTANT NOTE: An input report Print -Out from EnergyGauge Com of this design building must be submitted along with this Compliance Report. 8/l/2006 EnergyGauge FlaCom v 2.11 FORM 40OA-2004 I hereby . certify that the p!ans, and specifications covered 6y1h1s,calculation,are in compliance with' the Florida , Energy Efficiency Code. PREPARED BY: GUS BOBES JR P.E. DATE: I hereby certify that this b`ui!ding is in compliance with the Florida Energy Eicier/cy;-Code. Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed, this building will be inspected for compliance in accordance with Section 553.908, F.S. BUILDING OFFICIAL: DATE: OWNER AGENT: DATE: If required by Florida law, I hereby certify (') that the system design is in compliance with the Florida Energy Code. ARCHITECT : ELECTRICAL SYSTEM DESIGNER: LIGHTING SYSTEM DESIGNER: MECHANICAL SYSTEM DESIGNER: PLUMBING SYSTEM DESIGNER: REGISTRATION No. (') Signature is required where Florida Law requires design to be performed by registered design professionals. Typed names and registration numbers may be used'where all relevant information is contained on signed/sealed plans. 8/1/2006 EnergyGauge FlaCom v 2.11 FORM 40OA-2004 2 i Project: PRECPROTH Title: PRECISION PROSTHETICS Type: Office (WEA File: Orlando.TMY) Whole Building Compliance Design Reference Total 68.53 100.00 $2, 641.62 $3, 807.41 ELECTRICITY(MBtu/kWh/$ 68.53 100.00 52,413.00 76,454.00 $2, 641.62 $3, 807.41 AREA LIGHTS 14.41 16.71 11,025.00 12,774.00 $555.66 $636.15 MISC EQUIPMT 10.89 10.89 8,334.00 8,334.00 $420.03 $415.03 PUMPS & MISC 0.08 0.08 60.00 62.00 $3.02 $3.09 SPACE COOL 18.36 19.74 14,047.00 15,077.00 $70Z97 $750.83 VENT FANS 24.80 52.59 18,947.00 40,207.00 $954.93 $2, 002.31 Credits & Penalties (if any): Modified Points: = 68.54 PASSES External Lighting Compliance Description Category Allowance Area or Length ELPA CLP (W/Unit) or No. of Units (W) (W) (Sgft or ft) None 8/1/2006 EnergyGauge FlaCom v 2.11 FORM 40OA-2004 3 Project: PRECPROTH Title: PRECISION PROSTHETICS Type: Office (WEA File: Orlando.TMY) Lighting Controls Compliance Acronym Ashrae Description Area No. of Design Min Compli- ID (sq.ft) Tasks CP CP ance PrOZo 1 Sp 1 16 Office - Open Plan 2,976 1 3 2 PASSES Pr0Zo2Sp 1 16 Office - Open Plan 816 1 3 1 PASSES PASSES Project: PRECPROTH Title: PRECISION PROSTHETICS Type: Office (WEA File: Orlando.TMY) System Report Compliance PrOSyl System 1 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 2 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System . Air Cooled < 65000 Btu/h 13.00 10.00 13.00 PASSES Cooling Capacity Air Handling Air Handler (Supply) - 0.45 0.90 PASSES System -Supply Constant Volume PrOSy2 System 2 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled < 65000 Btu/h 13.00 10.00 13.00 PASSES Cooling Capacity Air Handling Air Handler (Supply) - 0.34 0.90 PASSES System -Supply Constant Volume PASSES 8/1/2006 EnergyGauge FlaCom v 2.11 FORM 40OA-2004 Plant Compliance Description Installed Size Design Min Design Min Category Comp No Eff Eff IPLV IPLV liance None Project: PRECPROTH Title: PRECISION PROSTHETICS Type: Office (WEA File: Orlando.TMY) 11 Water Heater Compliance 11 Description Water Heater 1 Type Category Design Min Design Max Comp Eff Eff Loss Loss liance Electric water heater > 12 [kW] 0.85 0.02 267.41 PASSES PASSES Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance [inches] Runout? Temp [Btu-in/hr Thick [in] Thick [in] [F] SF.F] None 8/l/2006 EnergyGauge FlaCom v 2.11 FORM 40OA-2004 G Project: PRECPROTH Title: PRECISION PROSTHETICS Type: Office (WEA File: Orlando.TMY) Other Required Compliance Category Section Requirement (write N/A in box if not applicable) Check Infiltration 406.1 Infiltration Criteria have been met System 407.1 HVAC Load sizing has been performed Ventilation 409.1 Ventilation criteria have been met ADS 410.1 Duct sizing and Design have been performed T &. B 410.1 Testing and Balancing will be performed Motors 414.1 Motor efficiency criteria have been met Lighting 415.1 Lighting criteria have been met ❑ O & M 102.1 Operation/maintenance manual will be provided to owner Roof/Ceil 404.1 R-19 for Roof Deck with supply plenums beneath it Report 101 Input Report Print -Out from EnergyGauge FlaCom attached? El 8/1/2006 EnergyGauge FlaCom v 2.11 FORM 40OA-2004 6 EnergyGauge FlaCom v 2.11 INPUT DATA REPORT Project Information Project Name: PRECPROTH Project Title: PRECISION PROSTHETICS Address: 1255 & 1259 WEST AIRPORT BLVD State: FL Zip: 0 Owner: Zones Orientation: North Building Type: Office Building Classification: Renovation to existing building No.of Storeys: I GrossArea: 3792 No Acronym Description Type Area Multiplier Total Area lsfl lstl 1 PrOZol Zone 1 CONDITIONED 2976.0 1 2976.0 2 PrOZo2 Zone 2 CONDITIONED 816.0 1 816.0 8/1/2006 EnergyGauge FlaCom v 2.11 1 Spaces No Acronym Description Type Depth Width Height Multi Total Area Total Volume IN IN [ft] plier ]sf] lef] In Zone: Pr0Zo1 1 Pr0ZolSp1 Zo0Spl Office - Open Plan 62.00 48.00 11.50 1 2976.0 34224.0 In Zone: PrOZo2 1 Pr0Zo2Sp1 Zo0Sp1 Office - Open Plan 17.00 48.00 11.50 1 816.0 9384.0 Lighting No Type Category No. of Watts per Power Control Type No.of Luminaires Luminaire [W] Ctrl pts In Zone: PrOZol In Space: PrOZo1Sp1 1 Recessed Fluorescent - General Lighting 1 960 960 Manual On/Off 1 No vent 2 Recessed Fluorescent - General Lighting 1 960 960 Manual On/Off 1 No vent 3 Recessed Fluorescent - General Lighting 1 960 960 Manual On/Off 1 No vent In Zone: PrOZo2 In Space: Pr0Zo2Sp1 1 Recessed Fluorescent - General Lighting 1 360 360 Manual On/Off 2 No vent 2 Recessed Fluorescent - No General Lighting 1 360 360 Manual On/Off 1 vent Walls No Description Type Width H (Effec) Multi Area DirectionConductance Heat Dens. R-Value IN IN plier [sf] [Btu/hr. sf. F] Capacity [lb/cf] [h.sf.F/Btu] [Btu/sLF] In Zone: PrOZol 8/1/2006 EnergyGauge FlaCom v 2.11 2 I PrOZo 1 Wa 1 Metal 48.00 12.00 1 siding/R 11 Batt/O.5" Gyp 2 PrOZo1Wa2 Metal 79.00 12.00 1 siding/R11 Batt/0.5" Gyp 3 PrOZo 1 Wa3 Metal 48.00 12.00 1 siding/Rl lBatt/0.5" Gyp 576.0 East 0.0957 0.7570 16.80 10.45 948.0 South 0.0957 0.7570 16.80 10.45 576.0 West 0.0957 0.7570 16.80 10.45 Windows No Description Type Shaded U SHG Vis.Tr W H (Effec) Multi Total Area [Btu/hr sf F] IN IN plier [Sf1 In Zone: PrOZol In Wall: PrOZo1Wal 1 PrOZolWalWil SINGLE CLEAR No 1.0018 0.81 0.88 6.00 8.00 2 96.0 In Wall: PrOZo1Wa2 1 PrOZo1Wa2Wi1 SINGLECLEAR No 1.0018 0.81 0.88 10.00 8.00 1 80.0 In Wall: PrOZo1Wa3 1 PrOZo1Wa3Wil SINGLE CLEAR No 1.0018 0.81 0.88 3.00 7.00 2 42.0 Doors No Description Type Shaded? Width H (Effec) Multi Area Cond. Dens. Heat Cap. R-Value [ft] [ft] plier [sf] [Btu/hr. sL F] [lb/cf] [Btu/sL F1 [h.sLFBtu] In Zone: In Wall: 0 Roofs No Description Type Width H (Effec) Multi Area Tilt Cond. Heat Cap Dens. R-Value [ft] [ft]- plier [sf] [deg] [Btu/hr. Sf. F] [Btu/st. F1 [lb/cf] [h.sf.F/Btu] In Zone: PrOZol 8/1/2006 EnergyGauge FlaCom v 2.11 3 I PrOZo1Rfl Mtl Bldg Roof/R-19 Batt 48.00 62.00 1 2976.0 0.00 0.0492 1.34 9.49 20.34 ❑ In Zone: PrOZo2 1 PrOZo2Rfl Mtl Bldg Roof/R-19 Batt 48.00 17.00 1 816.0 0.00 0.0492 1.34 9.49 20.34 ❑ Skylights No Description Type U SHGC Vis.Trans W H (Effec) Multiplier Area Total Area [Btu/hr sf F] [ft] [ft] [sf] [Sf] In Zone: In Roof: Floors No Description Type Width H (Effec) Multi Area Cond. Heat Cap. Dens. R-Value IN IN plier [sfJ [Btu/hr. sf. F] [Btu/sf. F] [Ib/cf] [h.sf.F/Btu] In Zone: PrOZol 1 PrOZolFl1 Concrete floor, carpet and rubber 48.00 62.00 1 2976.0 0.5987 9.33 140.00 1.67 0 pad In Zone: PrOZo2 1 PrOZo2F11 Concrete floor, carpet and rubber 48.00 17.00 1 816.0 0.5987 9.33 140.00 1.67 ❑ pad Systems 8/1/2006 EnergyGauge FlaCom v 2.11 PrOSyl System I Constant Volume Air Cooled Split No. Of Units 2 System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System (Air Cooled < 65000 Btu/h Cooling Capacity) 2 Air Handling System -Supply (Air Handler (Supply) - Constant Volume) 60000.00 13.00 13.00 1950.00 0.45 EJ PrOSy2 System 2 Constant Volume Air Cooled Split No. Of Units I System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System (Air Cooled < 65000 Btu/h Cooling Capacity) 2 Air Handling System -Supply (Air Handler (Supply) - Constant Volume) 36000.00 13.00 13.00 1200.00 0.34 ID Plant Equipment Category Size Inst.No Eff. IPLV Water Heaters W-Heater Description Capacit Cap.Unit UP Rt. Efficienc Loss 1 Electric water heater 50 [Gal] 16382 [kW] 0.8500 [Ef] 0.0200 [Btu/h] ❑ Ext-Lighting Description Category No. of Watts per Area/Len/No. of units Control Type Wattage Luminaires Luminaire [sf/ft/No] [W] EJ 8/l/2006 EnergyGauge F1aCom v 2.11 Piping No Type Operating Insulation Nomonal pipe Insulation Is Runout? Temperature Conductivity Diameter Thickness [F] [ Btu-in/h.sf.F] [in] [in] Fenestration Used Name Glass Type No. of Glass SHGC VLT Conductance Panes [Btu/h.sf.F] ApLbWndl SINGLE CLEAR 1 1.0018 0.8150 0.8810 ❑ Materials Used Mat No Acronym Description Only R-Value RValue Thickness Conductivity Density SpecificHeat Used [h.sf.F/Btu] [ft] [Btu/h.ft.F] [lb/cf] [Btu/lb.F] 187 Mat1187 GYP OR PLAS No 0.4533 0.0417 0.0920 50.00 0.2000 0 BOARD,1 /21N 151 Matll51 CONC HW, DRD, 140LB, No 0.4403 0.3333 0.7570 140.00 0.2000 ❑ 41N 178 Mat1178 CARPET W/RUBBER PAD Yes 1.2300 ❑ 12 Mat112 3 in. Insulation No 10.0000 0.2500 0.0250 2.00 0.2000 ❑ 23 Mat123 6 in. Insulation No 20.0000 0.5000 0.0250 5.70 0.2000 ❑ 4 Mat14 Steel siding No 0.0002 0.0050 26.0000 480.00 0.1000 ❑ 94 Mat194 BUILT-UP ROOFING, No 0.3366 0.0313 0.0930 70.00 0.3500 ❑ 3/8IN 8/1/2006 EnergyGauge F1aCom v 2.11 .Constructs Used No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [Ib/cf] [h.sf.FBtu] 1004 Concrete floor-, carpet and rubber pad No No 0.60 9.33 140.00 1.6703 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 151 CONC HW, DRD, 140LB, 41N 0.3333 0.00 ❑ 2 178 CARPET W/RUBBER PAD 0.00 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [Ib/cf] [h.sf.F/Btu] 1020 Metal siding/R11Batt/0.5"Gyp No No 0.10 0.76 16.80 10.4535 ❑ Layer Material Material Thickness Framing No. IN Factor 1 4 Steel siding 0.0050 0.00 ❑ 2 12 . 3 in. Insulation 0.2500 0.00 ❑ 3 187 GYP OR PLAS BOARD,1/21N 0.0417 0.00 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sLF] [lb/cf] [h.sf.F/Btu] 1047 Mtl Bldg Roof/R-19 Batt No No 0.05 1.34 9.49 20.3366 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 94 BUILT-UP ROOFING, 3/8IN 0.0313 0.00 ❑ 2 23 6 in. Insulation 0.5000 0.00 ❑ 8/1/2006 EnergyGauge F1aCom v 2.11