HomeMy WebLinkAbout241 Bellagio CirSANFORDTIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772 (407) 302-1091 / FAX (407) 302-2625 T Plans Review Sheet Date: 8/03/07 Business Address: 241 Bellagio circle #9 Occ. Business Business Name: The Fountain Market Place Ph. (407)264-0100 Contractor: ADTsecurity Fax (407)712-1813 Reviewed [ ] Reviewed with comment [ x ]j Rejected [ ] Reviewed by: Orlando Nunez, Fire Inspector/Plans Examiner Comment: 1.1 Application — The following items submitted for permitting 1.2 Will need to submit approved sprinkler plans. Please call (407) 302-2520 Inspector Minnetto for fire inspections 48 notice required on all inspections. 1 PROJECT SUMMARY Short Desc: Tennant Suite # 9 Description: Tennant Suite # 9 Owner: Addressl: 241 Bellagio Circle City: Sanford Address2: State: Florida Zip: 32771 Type: Office Class: Renovation to existing builc Jurisdiction: SANFORD, SEMINOLE COUNTY, FL (691500) Cond Area: 2173 SF Cond & UnCond Area: 2173 SF No of Storeys: 2 Area entered from Plans 2173 SF Permit No: 0 Max Tonnage 5 If different, write in: k� # 7/18/2007 EnergyGauge FLA/CO 20 .00 Compliance Summary Component Design Criteria Result Gross Energy Use 1,772.0 2,175.E PASSES LIGHTING CONTROLS EXTERNAL LIGHTING HVAC SYSTEM PLANT WATER HEATING SYSTEMS PIPING SYSTEMS Met all required compliance from Check List? PASSE PASSES PASSE None Entered None Entered None Entered ( `No/NA RTANT NOTE: An input report of this design building must be submitted with this Compliance Report. 7/18/2007 EnergyGauge FLA/COM 2004 v3.00 2 CERTIFICATIONS I hereby certify that the plans a d specifications covered by this calculation are in compliance with the Florida Energy Code Prepared By: Building Official: Date" 7/11 ` Date" I certify that this building is in compliance with the FLorida Energy Efficiency Code Owner Agent: Date: If Required by Florida law, I hereby ce {*) that th sy sign in compliance with the FLorida Energy Efficiency Code Architect: Reg No: i t �p Electrical Designer: Reg No: Lighting Designer Reg No: Mechanical Designer: I�:. Reg No: C& Ala SYs Plumbing Designer: Reg No: {*) Signature is required where Florida Law requires design to be performed by registered design professionals" Typed names and registration numbers may be used where all relevant information is contained on signed/sealed plans. nergyGauge Summit v3.10 incorporating Florida Energy Code Version - FLA/C7M 2004 v21 3 Project: Tennant Suite # 9 Title: Tennant Suite # 9 Type: Office (WEA File: Orlando.TMY) Whole Building Compliance Design Reference Total 79.58 100.00 $1, 772 $21176 ELECTRICITY(MBtu/k 79.58 100.00 Wh/$) 34475 43338 $1,772 $2,176 AREA LIGHTS 26.57 16.57 11502 7176 $591 $360 MISC EQUIPMT 8.65 8.65 3762 3762 $193 $189 PUMPS & MISC 0.14 0.14 64 64 $3 $3 SPACE COOL 27.99 24.07 12124 10419 $623 $523 VENT FANS 16.23 50.57 7023 21917 $361 $1,100 Credits & Penalties (if any): Modified Points: = 79.59 PASSES 7/18/2007 EnergyGauge FLA/COM 2004 v3.00 Project: Tennant Suite # 9 Title: Tennant Suite # 9 Type: Office (WEA File: Orlando.TMY) External Lighting Compliance Description Category Allowance Area or Length ELPA CLP (W/Unit) or No. of Units (W) (W) (Sgft or ft) Ext Light I Other (doors) than main entries 20.00 18.0 360 100 Design: 300 (W) PASSES Allowance: 360 (W) Project: Tennant Suite # 9 Title: Tennant Suite # 9 Type: Office (WEA File: Orlando.TMY) Lighting Controls Compliance Acronym Ashrae Description Area No. of Design Min Compli- ID (sq.ft) Tasks CP CP ance Reception 12 Lobby (General) - Reception and 287 1 2 1 PASSES Waiting Toilet 6 Toilet and Washroom 57 1 1 1 PASSES Corridor 5 Corridor 80 1 1 1 PASSES Open Work Area 16 Office - Open Plan 1,004 1 2 1 PASSES Office 17 Office - Enclosed 144 1 2 1 PASSES Offices 17 Office - Enclosed 510 1 4 1 PASSES Stair 4 Stair - Active Traffic 91 1 1 1 PASSES PASSES 7/18/2007 EnergyGauge FLA/COM 2004 v3.00 Project: Tennant Suite # 9 Title: Tennant Suite # 9 Type: Office (WEA File: Orlando.TMV) System Report Compliance RTU-1 System 1 Constant Volume Packaged No. of Units System 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled < 65000 Btu/h 13.00 13.00 13.00 PASSES Cooling Capacity Air Handling Air Handler (Supply) - 0.31 0.90 PASSES System -Supply Constant Volume RTU-2 System 2 Constant Volume Air Cooled No. of Units Single Package System < 65000 Rtu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled < 65000 Btu/h 13.00 13.00 13.00 PASSES Cooling Capacity Air Handling Air Handler (Supply) - 0.23 0.90 PASSES System -Supply Constant Volume PASSES Plant Compliance Description Installed Size Design Min Design Min Category Comp No Eff Eff IPLV IPLV liance None -, Water Heater Compliance Description Type Category Design Min Design Max Comp Eff Eff Loss Loss liance None 7/18/2007 EnergyGauge FLA/COM 2004 v3.00 Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance [inches] Runout? Temp [Btu-in/hr Thick [in] Thick [in] [F] SF.F] None Project: Tennant Suite # 9 Title: Tennant Suite # 9 Type: Office (WEA File: Orlando.TMY) Other Required Compliance Category Section Requirement (write N/A in box if not applicable) Check Infiltration 406.1 Infiltration Criteria have been met System 407.1 HVAC Load sizing has been performed d Ventilation 409.1 Ventilation criteria have been met d ADS 410.1 Duct sizing and Design have been performed T & B 410.1 Testing and Balancing will be performed Motors 414.1 Motor efficiency criteria have been met Lighting 415.1 Lighting criteria have been met O & M 102.1 Operation/maintenance manual will be provided to owner Roof/Ceil 404.1 R-19 for Roof Deck with supply plenums beneath it Report 101 Input Report Print -Out from EnergyGauge FlaCom attached? 7/18/2007 EnergyGauge FLA/COM 2004 v3.00 Project Name: Tennant Suite # 9 Project Title: Tennant Suite # 9 Address: 241 Bellagio Circle State: Florida Zip: 32771 Owner: EnergyGauge FLAXOM 2004 v3.00 INPUT DATA REPORT Project Information Orientation: North Building Type: Office Building Classification: Renovation to existing building No.of Storeys: 2 GrossArea: 2173 SF Zones No Acronym Description Type Area Multiplier Total Area [sal 1S11 1 1 St Floor Zone 1 CONDITIONED 1572.3 1 1572.3 ❑ 2 2 nd Floor Zone 2 CONDITIONED 600.6 1 600.6 ❑ 7/18/2007 EnergyGauge FLA/COM 2004 Q.00 1 Spaces No Acronym Description Type Depth Width Height Multi Total Area Total Volume [ft] IN [ft] plier [sf] [cf] In Zone: 1 St Floor 1 Reception Zo0Sp1 Lobby (General) - Reception 22.10 13.00 10.00 1 287.3 2873.0 and Waiting 2 Toilet Zo0Sp2 Toilet and Washroom 8.50 6.66 9.00 1 56.6 509.5 3 Corridor Zo0Sp4 Corridor 20.00 4.00 9.00 1 80.0 720.0 4 Open Work ArZo0Sp6 Office - Open Plan 44.32 22.66 9.00 1 1004.4 9039.4 [l 5 Office Zo0Sp8 Office - Enclosed 10.00 14.40 9.00 1 144.0 1296.0 El In Zone: 2 nd Floor 1 Offices Zo0Sp1 Office - Enclosed 22.50 22.66 8.00 1 509.9 4078.8 2 Stair Zo0Sp3 Stair - Active Traffic 11.00 8.25 22.00 1 90.8 1996.5 Lighting No Type Category No. of Watts per Power Control Type No.of Luminaires Luminaire [W] Ctrl pts In Zone: 1 St Floor In Space: Reception 1 Incandescent General Lighting 8 60 480 Manual Continuous 2 Dimming In Space: Toilet 1 Compact Fluorescent General Lighting 2 34 68 Manual On/Off 1 (l In Space: Corridor 1 Incandescent General Lighting 2 60 120 Manual On/Off 1 E] In Space: Open Work Area 1 Recessed Fluorescent - General Lighting 13 128 1664 Manual On/Off 2 El No vent In Space: Office 7/18/2007 EnergyGauge FLA/COM 2004 v3.00 I Recessed Fluorescent - General Lighting 2 128 256 Manual On/Off 1 �] No vent 2 Incandescent General Lighting 4 60 240 Manual On/Off 1 [] In Zone: 2 nd Floor In Space: Offices 1 Recessed Fluorescent - General Lighting 7 128 896 Manual On/Off 4 [] No vent In Space: Stair 1 Suspended Fluorescent General Lighting 1 32 32 Manual On/Off 1 ❑ Walls No Description Type Width H (Effec) Multi Area DirectionConductance- Heat Dens. R-Value IN [ft] plier [sf] [Btu/hr. sf. F] Capacity [lb/cf] [b.sf.F/Btu] [Btu/sf.F] In Zone: 1 St Floor 1 PrOZolWal Concrete Tilt Wall 22.66 12.00 1 271.9 North 0.3139 14.496 119.74 3.2 ❑ w/ .75"ins./GypBd 2 PrOZo1Wa3 Concrete Tilt Wall 22.66 22.00 1 498.5 South 0.3139 14.496 119.74 3.2 ❑ w/ .75"ins./GypBd In Zone: 2 nd Floor 1 PrOZo2Wal Concrete Tilt Wall 22.66 11.00 1 249.3 North 0.3139 14.496 119.74 3.2 ❑ w/ .75"ins./GypBd 2 PrOZo2Wa2 Partition wall, 0.75 22.66 11.00 1 249.3 North 0.8350 2.500 100.00 1.2 Ej in. gyp, airspace, 0.75 in. gyp Windows No Description Type Shaded U SHGC Vis.Tra W H (Effec) Multi Total Area [Btu/hr sf F] IN [ft] plier [sf) In Zone: 1 St Floor In Wall: North 1 PrOZolWalWi1 UserDefined No 1.2500 0.82 0.76 4.66 8.00 2 74.6 ❑ 2 PrOZol Wal Wi2 UserDefined No 1.2500 0.82 0.76 6.00 8.00 1 48.0 7/18/2007 EnergyGauge FLA/COM 2004 v3.00 In Zone: 2 nd Floor In Wall: North 1 PrOZo2Wa1Wil User Defined No 1.2500 0.82 0.76 4.66 4.66 3 65.1 ❑ Doors No Description Type Shaded? Width H (Effec) Multi Area Cond. Dens. Heat Cap. R-Value [ft] [ft] plier [sf] [Btu/hr. sL F1 [lb/cf1 [Btu/sf. F] [h.sLFBtu] In Zone: 1 St Floor In Wall: South 1 PrOZo1Wa3Drl Hollow core flush No 10.00 12.00 1 120.0 0.7553 0.00 0.00 1.32 ❑ 2 PrOZolWa3Dr2 Panel with.7/16" No 10.00 12.00 1 120.0 0.9981 0.00 0.00 1.00 ❑ panels In Zone: 2 nd Floor In Wall: Partition 1 PrOZo2Wa2Drl Solid core flush No 3.00 6.66 1 20.0 0.3504 0.00 0.00 2.85 ❑ (2.25) Roofs No Description Type Width H (Effec) Multi Area Tilt Cond. Heat Cap Dens. R-Value [ft] IN plier [sf1 [deg] [Btu/hr. St F] [Btu/sE F1 [lb/cf] [b.sLF/Btu] In Zone: 1 St Floor 1 PrOZolRfl Mtl Bldg Roof/R-19 22.66 69.33 1 157LO 0.00 0.0492 1.34 9.49 20.3 ❑ Batt In one: 2 nd Floor 1 PrOZo2Rfl Mtl Bldg Roof/R-19 22.66 26.56 1 601.8 0.00 0.0492 1.34 9.49 20.3 ❑ Batt Skylights No Description Type U SHGC Vis.Trans W H (Effec) Multiplier Area Total Area [Btu/hr sf F1 [ft] [ft] [Sf] [Sf] 7/18/2007 EnergyGauge FLA/COM 2004 v3.00 In Zone: In Roof: Floors No Description Type Width H (Effec) Multi Area Cond. Heat Cap. Dens. R-Value [ft] [ft] plier [sf] [Btu/hr. sL F] [Btu/sf. F] [lb/cf] [h.sf.F/Btu] In Zone: 1 St Floor 1 Pr0Zo1F11 1 ft. soil, concrete 22.66 69.33 1 1571.0 0.1745 54.00 108.00 5.73 floor, carpet and rubber. pad Systems RTU-1 System 1 Constant Volume Packaged System No. Of Units 1 Component Category Capacity Efficiency IPLV 1 2 Cooling System (Air Cooled < 65000 Btu/h Cooling Capacity) Air Handling System -Supply (Air Handler (Supply) - Constant Volume) 60000.00 13.00 13.00 1980.00 0.31 ❑ ❑ RTU-2 System 2 Constant Volume Air Cooled Single Package System < 65000 Btu/hr No. Of Units 1 Component Category Capacity Efficiency IPLV 1 .2 Cooling System (Air Cooled < 65000 Btu/h Cooling Capacity) Air Handling System -Supply (Air Handler (Supply) - Constant Volume) 24000.00 13.00 13.00 800.00 0.23 [� Plant Equipment Category Size Inst.No Eff. ]PLV 7/18/2007 EnergyGauge FLA/COM 2004 Q.00 El Water Heaters W-Heater Description Capacit3Cap.Unit I/P Rt. Efficiency Loss lij EA -Lighting Description Category No. of Luminaires Watts per Area/Len/No. of units Luminaire [sf/ft/No] Control Type Wattage [W] 1 Ext Light 1 Other (doors) than main 3 entries 100 18.00 Astronomical Timer Coi 300.00 ❑ Piping No Type Operating Temperature [F] Insulation Conductivity [ Btu-in/h.sf.F] Nomonal pipe Diameter [in] Insulation Is Runout? Thickness [in] ED Fenestration Used Name Glass Type No. of Glass SHGC VLT Panes Conductance [Btu/h.sf.F] ASHULSg1CIrAll User Defined 1 1.2500 0.8200 0.7600 ❑ Frm 7/18/2007 EnergyGauge FLA/COM 2004 v3.00 Materials Used Mat No Acronym Description Only R-Value RValue Thickness Conductivity Density SpecificHeat Used [h.sEFBtu] IN [Btu/h.ft.F] [lb/cf] [Btu/lb.F] 187 Mat1187 GYP OR PLAS No 0.4533 0.0417 0.0920 50.00 0.2000 ❑ BOARD,1 /21N 178 Mat1178 CARPET W/RUBBER PAD Yes 1.2300 ❑ 265 Mat1265 Soil, 1 ft No 2.0000 1.0000 0.5000 100.00 0.2000 ❑ 48 Matl48 6 in. Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000 ❑ 57 Mat157 3/4 in. Plaster or gypsum No 0.1488 0.0625 0.4200 100.00 0.2000 ❑ 72 Mat172 AIR LAYER, 3/41N OR Yes 0.9000 ❑ LESS, VERT. WALLS 269 Mat1269 .75" ISO BTWN24" oc No 2.2321 0.0625 0.0280 4.19 0.3000 ❑ 23 Matl23 6 in. Insulation No 20.0000 0.5000 0.0250 5.70 0.2000 ❑ 94 Mat194 BUILT-UP ROOFING, No 0.3366 0.0313 0.0930 70.00 0.3500 ❑ 3/8IN Constructs Used No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sEF] [Btu/sf.F] [lb/cf] [h.sf.F/Btu] 1024 Panel with 7/16" panels No Yes 1.00 1.0 ❑ Layer Material Material Thickness Framing No. IN Factor 1 275 Panel with 7/16" panels (1.375") 0.000 ❑ 7/18/2007 EnergyGauge FLA/COM 2004 v3.00 Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.FBtu] 1025 Hollow core flush No Yes 0.76 1.3 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 276 Hollow core flush (1.75") 0.000 ❑ . Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.F/Btu] 1047 Mtl Bldg Roof/R-19 Batt No No 0.05 1.34 9.49 20.3 ❑ Layer Material Material Thickness Framing No. IN Factor 1 94 BUILT-UP ROOFING, 3/81N 0.0313 0.000 ❑ 2 23 , 6 in. Insulation. 0.5000 0.000 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.FBtu] 1056 Concrete Tilt Wall w/ .75"ins./GypBd No No 0.31 14.50 119.74 3.2 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 48 6 in. Heavyweight concrete 0.5000 0.000 ❑ 2 269 .75" ISO BTWN24" oc 0.0625 0.000 ❑ 3 187 GYP OR PLAS BOARD,1/21N 0.0417 0.000 ❑ 7/18/2007 EnergyGauge FLA/COM 2004 v3.00 8 Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sLF] [Btu/sf.F'] [ib/cf] [h.sf.FBtu] 1057 1 ft. soil, concrete floor, carpet and rubber pad No No 0.17 54.00 108.00 5.7 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 265 Soil, 1 ft 2.0000 0.000 ❑ 2 48 6 in. Heavyweight concrete 0.5000 0.000 ❑ 3 178 CARPET W/RUBBER PAD 0.000 ❑ Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sf.F] [Btu/sf.F] [Ib/cf] [h.sf.F/Btn] 1058 Solid core flush (2.25) No Yes 0.35 2.9 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 279 Solid core flush (2.25"), 0.000 ❑ Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.FBtu] 1059 Partition wall, 0.75 in. gyp, airspace, 0.75 in. No No 0.83 2.50 100.00 1.2 ❑ gyp Layer Material Material Thickness Framing No. [ft] Factor 1 57 3/4 in. Plaster or gypsum 0.0625 0.000 ❑ 2 72 AIR LAYER, 3/41N OR LESS, VERT. 0.000 ❑ WALLS 3 57 3/4 in. Plaster or gypsum 0.0625 0.000 ❑ 7/1.8/2007 EnergyGauge FLA/COM 2004 v3.00 9