HomeMy WebLinkAbout249 Bellagio CirSANFORD FIRE DEPARTMENT
FIRE PREVENTION DIVISION
300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl.
32772
(407) 302-1091 / FAX (407) 302-2625
F D
Plans Review Sheet
Date: 8/03/07 Business Address: 249 Bellagio circle #07 Occ. Business
Business Name: The Fountain Market Place Ph. (407)264-0100
Contractor: ADT security Fax (407)712-1813
Reviewed [ ] Reviewed with comment [.x ]I Rejected [ ]
Reviewed by: Orlando Nunez, Fire Inspector/Plans Examiner
Comment:
1.1 Application — The following items submitted for permitting
1.2 Will need to submit approved sprinkler plans.
Please call (407) 302-1022 Inspector James for fire inspections 48 notice required on all inspections.
1
PROJECT SUMMARY
Short Desc: Tennant Suite # 7 Description: Tennant Suite # 7
Owner:
Addressl: 249 Bellagio Circle City: Sanford
Addressl: State: Florida
Zip: 32771
Type: Office Class: Renovation to existing
Jurisdiction: SANFORD, SEMINOLE COUNTY, FL (691500)
Cond Area: 2173 SF Cond & UnCond Area: 2173 SF
No of Storeys: 2 Area entered from Plans 2173 SF
Permit No: 0 Max Tonnage 5
If different, write in:
Compliance Summary
Component Design Criteria Result
Gross Energy Use 1,856.3 2,219.E CPASSES
LIGHTING CONTROLS
EXTERNAL LIGHTING
HVAC SYSTEM
PLANT
WATER HEATING SYSTEMS
PIPING SYSTEMS
Met all required compliance from Check List?
PASSE
ASSES
ASSE
None Entered
None Entered
None Entered
'eglo/NA
IMPORTANT NOTE: An input report of this design building must be submitted
along with this Compliance Report.
7/18/2007 EnergyGauge FLA/COM 2004 v3.00 2
CERTIFICATIONS
I hereby certify that the plans a d specifications covered by this calculation are in compliance with the
Florida Energy Code
Prepared By: Building Official: T
Date 1&fp Date:
I certify that this building is in compliance with the FLorida Energy Efficiency Code
Owner Agent: Date:
If Required by Florida law, I hereby ce " (`) that the sign is ' compliance with the FLorida
Energy Efficiency Code
Architect: _Reg No:
Electrical Designer: Reg No:
Lighting Designer Reg No:
Mechanical Designer: 10 Oj&oV &A /I4(i Reg Na: (AQX V4 --
Plumbing Designer: _ Reg No:
{') Signature is required where Florida Law requires design to be performed by registered design
professionals. Typed names and registration numbers may be used where all relevant information is
contained on signed/sealed plans.
nergyGauge Summit v3.10 incorporating Florida Energy Code Version - FLA/COM 2004 v2.f 3
Project: Tennant Suite # 7
Title: Tennant Suite # 7
Type: Office
(WEA File: Orlando.TMY)
Whole Building Compliance
Design
Reference
Total
81.60
100.00
$1,856
$2,220
ELECTRICITY(MBtu/k
81.60
100.00
Wh/$)
36114
44304
$1,856
$2,220
AREA LIGHTS
29.05
16.15
12857
7162
$661
$359
MISC EQUIPMT
7.21
7.21
3194
3194
$164
$160
PUMPS & MISC
0.1.3
0.13
64
64
$3
$3
SPACE COOL
28.33
24.16
12539
10702
$645
$536
VENT FANS
16.88
52.35
7460
23182
$383
$1,161
Credits & Penalties (if any): Modified Points: = 81.61
PASSES
7/18/2007 EnergyGauge FLA/COM 2004 v3.00
Project: Tennant Suite # 7
Title: Tennant Suite # 7
Type: Office
(WEA File: Orlando.TMY)
External Lighting Compliance
Description
Category Allowance Area or Length ELPA CLP
(W/Unit) or No. of Units (W) (W)
(Sgft or ft)
Ext Light 1
Other (doors) than main entries 20.00 18.0 360 100
Design: 300 (W)
PASSES
,Allowance: Allowance: 360 (W)
Project: Tennant Suite # 7
Title: Tennant Suite # 7
Type: Office
(WEA File: Orlando.TMY)
Lighting Controls Compliance
Acronym
Ashrae
Description
Area
No. of
Design
Min
Compli-
ID
(sq.ft)
Tasks
CP
CP
ance
Reception
12
Lobby (General) - Reception and
286
1
2
1
PASSES
Waiting
Toilet
6
Toilet and Washroom
57
1
1
1
PASSES
Corridor
5
Corridor
152
1
2
1
PASSES
Open Work Area
16
Office - Open Plan
156
1
1
1
PASSES
Conference
15
Conference/meeting (Multiple
204
1
1
1
PASSES
Functions)
Offices
17
Office - Enclosed
715
1
7
1
PASSES
Offices
17
Office - Enclosed
510
1
4
1
PASSES
Stair
4
Stair - Active Traffic
94
1
1
1
PASSES
�— PASSES
7/18/2007 EnergyGauge FLA/COM 2004 v3.00
Project: Tennant Suite # 7
Title: Tennant Suite # 7
Type: Office
(WEA File: Orlando.TMY)
System Report Compliance
RTU-1 System 1
Constant Volume Packaged No. of Units
System 1
Component Category
Capacity Design Eff Design IPLV Comp-
Eff Criteria IPLV Criteria liance
Cooling System Air Cooled < 65000 Btu/h
13.00 13.00 13.00 PASSES
Cooling Capacity
Air Handling Air Handler (Supply) -
0.31 0.90 PASSES
System -Supply Constant Volume
RTU-2 System 2
Constant Volume Air Cooled No. of Units
Single Package System < 1
65000 Rtu/hr
Component Category
Capacity Design Eff Design IPLV Comp-
Eff Criteria 1PLV Criteria liance
Cooling System Air Cooled < 65000 Btu/h
13.00 13.00 13.00 PASSES
Cooling Capacity
Air Handling Air Handler (Supply) -
0.23 0.90 PASSES
System -Supply Constant Volume
PASSES
Plant Compliance
Description Installed Size Design Min Design Min Category Comp
No Eff Eff IPLV IPLV liance
�— None
Water Heater Compliance
Description Type Category Design Min Design Max Comp
Eff Eff Loss Loss liance
None
7/18/2007 EnergyGauge FLA/COM 2004 v3.00
Piping System Compliance
Category
Pipe Dia Is Operating Ins Cond Ins Req Ins
Compliance
[inches] Runout? Temp [Btu-in/hr Thick [in] Thick [in]
[F] SF.F]
None
Project: Tennant Suite # 7
Title: Tennant Suite # 7
Type: Office
(WEA File: Orlando.TMY)
Other Required Compliance
Category
Section
Requirement (write N/A in box if not applicable)
Check
Infiltration
406.1
Infiltration Criteria have been met
System
407.1
RVAC Load sizing has been performed
Ventilation
409.1
Ventilation criteria have been met
ADS
410.1
Duct sizing and Design have been performed
T & B
410.1
Testing and Balancing will be performed
Motors
414.1
Motor efficiency criteria have been met
Lighting
415.1
Lighting criteria have been met
O & M
102.1
Operation/maintenance manual will be provided to owner
Roof/Ceil
404.1
R-19 for Roof Deck with supply plenums beneath it
Report
101
Input Report Print -Out from EnergyGauge F1aCom attached?
7/18/2007 EnergyGauge FLA/COM 2004 v3.00
Project Name: Tennant Suite # 7
Project Title: Tennant Suite # 7
Address: 249 Bellagio Circle
State: Florida
Zip: 32771
Owner:
EnergyGauge FLAXOM 2004 v3.00
INPUT DATA REPORT
Project Information
Orientation: North
Building Type: Office
Building Classification: Renovation to existing building
No.of Storeys: 2
GrossArea: 2173 SF
Zones
No Acronym Description Type Area Multiplier Total Area
[sit [sal
1 1 St Floor Zone 1 CONDITIONED 1569.6 1 1569.6
2 2 nd Floor Zone 2 CONDITIONED 603.4 1 603.4
7/18/2007 EnergyGauge FLA/COM 2004 v3.00 1
Spaces
No Acronym Description
Type
Depth
Width
Height
Multi Total Area
Total Volume
IN
[ft]
[ft]
plier [sf]
[cf]
In Zone: 1 St Floor
1 Reception Zo0Sp1
Lobby (General) - Reception 22.00
13.00
10.00
1 286.0
2860.0
and Waiting
2 Toilet ZoOSp2
Toilet and Washroom
8.50
6.66
9.00
1 56.6
509.5
El
3 Corridor ZoOSp4
Corridor
38.00
4.00
9.00
1 152.0
1368.0
n
4 Open Work ArZoOSp6
Office - Open Plan
13.00
12.00
9.00
1 156.0
1404.0
El
5 Conference ZoOSp7
Conference/meeting
18.50
11.00
9.00
1 203.5
1831.5
[�
(Multiple Functions)
6 Offices ZoOSp8
Office - Enclosed
40.40
17.71
9.00
1 715.5
6439.4
El
In Zone: 2 nd Floor
i Offices ZoOSp 1
Office - Enclosed
22.50
22.66
8.00
1 509.9
4078.8
[�
2 Stair ZoOSp3
Stair,- Active Traffic
11.00
8.50
22.00
1 93.5
2057.0
Lighting
No Type
Category
No. of
Watts per
Power
Control Type
No.of
Luminaires
Luminaire
[W]
Ctrl pts
In Zone: 1 St Floor
In Space: Reception
1 Incandescent
General Lighting
8
60
480
Manual Continuous
2
El
Dimming
In Space: Toilet
1 Compact Fluorescent
General Lighting
2
34
68
Manual On/Off
1
El
In Space: Corridor
I Recessed Fluorescent
- General Lighting
3
128
384
Manual On/Off
1
No vent
2 Compact Fluorescent
General Lighting
1
34
34
Manual On/Off
1
In Space: Open Work Area
7/18/2007 EnergyGauge FLA/COM 2004 v3.00
I Recessed Fluorescent - General Lighting
2
128
256
Manual On/Off
1
[]
No vent
In Space: Conference
1 Recessed Fluorescent - General Lighting
2
128
256
Manual On/Off
1
[]
No vent
In Space: Offices
1 Recessed Fluorescent - General Lighting
14
128
1792
Manual On/Off
7
❑
No vent
In Zone: 2 nd Floor
In Space: Offices
1 Recessed Fluorescent - General Lighting
7
128
896
Manual On/Off
4
[]
No vent
In Space: Stair
1 Suspended Fluorescent General Lighting
1
32
32
Manual On/Off
1
[]
Walls
No Description Type Width H (Effec) Multi
Area
DirectionConductance Heat
Dens.
R-Value
IN
[ft] plier
[sf]
[Btu/hr.
sf. F] Capacity
[lb/cf]
[h.sf.FBtu]
[Btu/sf.F]
In Zone: i St Floor
1 PrOZo1Wal Concrete Tilt Wall 22.66
12.00 1
271.9
North
0.3139 14.496
119.74
3.2 ❑
w/ .75"ins./GypBd
2 PrOZo1Wa3 Concrete Tilt Wall 22.66
22.00 1
498.5
South
0.3139 14.496
119.74
3.2 ❑
w/ .75"ins./GypBd
In Zone: 2 nd Floor
1 PrOZo2Wal Concrete Tilt Wall 22.66
11.00 1
249.3
North
0.3139 14.496
119.74
3.2 ❑
w/ .75"ins./GypBd
2 PrOZo2Wa2 Partition wall, 0.75 22.66
11.00 1
249.3
North
0.8350 2.500
100.00
1.2 ❑
in. gyp, airspace,
0.75 in. gyp
Windows
No Description Type Shaded U SHGC Vis.Tra
W
H (Effec) Multi
Total Area
[Btu/hr sf F]
IN
IN plier
[sf]
7/18/2007 EnergyGauge FLA/COM 2004 v3.00
In'Zone: 1 St Floor
In Wall: North
1 PrOZolWalWil User Defined
No
1.2500 0.82
0.76
4.66 8.00
2
74.6
❑
2 PrOZolWalWi2 User Defined
No
1.2500 0.82
0.76
6.00 8.00
1
48.0
❑
In Zone: 2 nd Floor
In Wall: North
1 PrOZo2WalWil User Defined
No
1.2500 0.82
0.76
4.66 4.66
3
65.1
❑
Doors
No Description Type
Shaded? Width H (Effec) Multi
Area Cond.
Dens. Heat Cap.
R-Value
[ft] [ft]
plier
[sf] [Btu/hr. sf. F] [lb/cf] [Btu/sf. F]
[h.sf.FBtu]
In Zone: 1 St Floor
In Wall: South
1 PrOZolWa3Drl Hollow core flush
No
10.00 12.00
1
120.0 0.7553
0.00
0.00
1.32
❑
In Zone: 2 nd Floor
In Wall: Partition
1 PrOZo2Wa2Drl Solid core flush
No
3.00 6.66
1
20.0 0.3504
0.00
0.00
2.85
❑
(2.25)
Roofs
No Description Type
Width
H (Effec) Multi
Area
Tilt Cond.
Heat Cap
Dens.
R-Value
[ft]
IN plier
[sf]
[deg] [Btu/hr. Sf. F]
[Btu/sf. F]
[lb/cf]
[h.sf.F/Btu]
In Zone: 1 St Floor
1 PrOZo1Rfl Mtl Bldg Roof/R-19
22.66
69.33 1
1571.0
0.00 0.0492
1.34
9.49
20.3
❑
Batt
In one: 2 nd Floor
1 PrOZo2Rfl Mtl Bldg Roof/R-19
22.66
26.56 1
601.8
0.00 0.0492
1.34
9.49
20.3
❑
Batt
Skylights
No Description Type
U SHGC Vis.Trans
W H (Effec) Multiplier
Area
Total Area
[Btu/hr sf F]
IN [ft]
[sf]
[Sf]
7/18/2007 EnergyGauge FLA/COM 2004 v3.00
In Zone:
In Roof:
Floors
No Description Type
Width H (Effec) Multi Area Cond. Beat Cap. Dens. R-Value
[ft] [ft] plier [sf] [Btu/hr. sf. F] [Btu/sf. F] [lb/cf] [h.sLF/Btu]
In Zone: 1 St Floor
1 PrOZoiFll 1 ft. soil, concrete
22.66 69.33 1 1571.0 0.1745 54,00 108.00 5,73 ❑
floor, carpet and
rubber pad
Systems
RTU-1
System 1
Constant Volume Packaged System
No. Of Units 1
Component
Category
Capacity Efficiency IPLV
1
2
Cooling System (Air Cooled < 65000 Btu/h Cooling
Capacity)
Air Handling System -Supply (Air Handler (Supply) -
Constant Volume)
60000.00 13.00 13.00
2140.00 0.31
❑
❑
RTU-2
System 2
Constant Volume Air Cooled Single
Package System < 65000 Btu/hr
No. Of Units 1
Component
Category
Capacity Efficiency IPLV
1
2
Cooling System (Air Cooled < 65000 Btu/h Cooling
Capacity)
Air Handling System -Supply (Air Handler (Supply) -
Constant Volume)
24000.00 13.00 13.00
800.00 0.23
❑
❑
Plant
Equipment Category
Size Inst.No Eff.
IPLV
7/18/2007 EnergyGauge FLA/COM 2004 v3.00
Water Heaters
W-Heater Description Capacit3Cap.Unit I/P Rt. Efficiency Loss
Ext-Lighting
Description Category No. of Watts per Area/Len/No. of units
Luminaires Luminaire [sf/ft/No]
Control Type Wattage
[W]
1 Ext Light 1 Other (doors) than main 3 100
entries
18.00 Astronomical Timer Coi 300.00 ❑
Piping
No Type Operating Insulation
Temperature Conductivity
[F] [ Btu-in/h.sf.F]
Nomonal pipe
Diameter
[in]
Insulation Is Runout?
Thickness
[in]
Fenestration Used
Name Glass Type No. of Glass SHGC VLT
Panes Conductance
[Btu/h.sf.F]
ASHULSg1CIrAll User Defined 1 1.2500 0.8200 0.7600 ❑
Frm
7/18/2007 EnergyGauge FLA/COM 2004 v3.00
Materials Used
Mat No
Acronym
Description
Only R-Value
RValue Thickness
Conductivity
Density
SpecificHeat
Used
[h.sf.FBtu]
IN
[Btu/h.ft.F]
[lb/cf]
[Btu/Ib.F]
187
Mat1187
GYP OR PLAS
No
0.4533
0.0417
0.0920
50.00
0.2000
❑
BOARD,1 /21N
178
Mat1178
CARPET W/RUBBER PAD
Yes
1.2300
❑
265
Mat1265
Soil, 1 ft
No
2.0000
1.0000
0.5000
100.00
0.2000
0
48
Matl48
6 in. Heavyweight concrete
No
0.5000
0.5000
1.0000
140.00
0.2000
❑
57
Matl57
3/4 in. Plaster or gypsum
No
0.1488
0.0625
0.4200
100.00
0.2000
❑
72
Mat172
AIR LAYER, 3/41N OR
Yes
0.9000
❑
LESS, VERT. WALLS
269
Mat1269
.75" ISO BTWN24" oc
No
2.2321
0.0625
0.0280
4.19
0.3000
❑
23
Mat123
6 in. Insulation
No
20.0000
0.5000
0.0250
5.70
0.2000
❑
94
Mat194
BUILT-UP ROOFING,
No
0.3366
0.0313
0.0930
70.00
0.3500
❑
3/81N
Constructs Used
No
Name
Simple
Massless Conductance Heat Capacity
Density
RValue
Construct
Construct [Btu/h.sf.F]
[Btu/sf.F]
[ib/cf]
[h.sf.F/Btu]
1025
Hollow core flush
No
Yes
0.76
1.3
❑
Layer
Material Material
Thickness
Framing
No.
IN
Factor
1
276 Hollow core flush (1.75")
0.000
❑
7/18/2007 EnergyGauge FLA/COM 2004 v3.00
No Name
Simple
Massless
Conductance Heat Capacity
Density
RValue
Construct
Construct
[Btufh.sf.F]
[Btu/sf.F]
[lb/cf]
[h.sfFBtu]
1047 Mtl Bldg Roof/R-19 Batt
No
No
0.05
1.34
9.49
20.3
❑
Layer
Material
Material
Thickness
Framing
No.
[ft]
Factor
1
94
BUILT-UP ROOFING, 3/81N
0.0313
0.000
❑
2
23
6 in. Insulation
0.5000
0.000
❑
Simple
Massless
Conductance Heat Capacity
Density
RValue
No Name
Construct
Construct
[Btu/h.sf.F]
[Btu/sf.F]
[lb/cf]
[h.sf.FBtu]
1056 Concrete Tilt Wall w/ .75"ins./GypBd No
No
0.31
14.50
119.74
3.2
❑
Layer
Material
Material
Thickness
Framing
No.
[ft]
Factor
1
48
6 in. Heavyweight concrete
0.5000
0.000
❑
2
269
.75" ISO BTWN24" oc
0.0625
0.000
❑
3
187
GYP OR PLAS BOARD,1/21N
0.0417
0.000
❑
No Name
Simple
Massless
Conductance Heat Capacity
Density
RValue
Construct
Construct
[Btu/h.sf.F]
[Btu/sf.F]
[lb/cf]
[h.sf.F/Btu]
1057 1 ft. soil, concrete floor, carpet and rubber pad No
No
0.17
54.00
108.00
5.7
❑
Layer
Material
Material
Thickness
Framing
No.
[ft]
Factor
1
265
Soil, I ft
2.0000
0.000
❑
2
48
6 in. Heavyweight concrete
0.5000
0.000
❑
3
178
CARPET W/RUBBER PAD
0.000
❑
7/18/2007 EnergyGauge FLA/COM 2004 v3.00 8
No
Name
Simple
Massless
Conductance Heat Capacity
Density
RValue
Construct
Construct
[Btu/h.sf.F]
[Btu/sf.F]
[lb/cf]
[h.sf.F/Btu]
1058
Solid core flush (2.25)
No
Yes
0.35
2.9
❑
Layer Material
Material
Thickness
Framing
No.
IN
Factor
t 279
Solid core flush (2.25")
0.000
❑
No
Name
Simple
Massless
Conductance Heat Capacity
Density
RValue
Construct
Construct
[Btu/h.sf.F]
[Btu/sf.F]
[lb/cf]
[h.sf.F/Btu]
1059
Partition wall, 0.75 in. gyp, airspace, 0.75 in. No
No
0.83
2.50
100.00
1.2
❑
gyp
Layer Material
Material
Thickness
Framing
No.
[ft]
Factor
1 57
3/4 in. Plaster or gypsum
0.0625
0.000
❑
2 72
AIR LAYER, 3/41N OR LESS, VERT.
0,000
❑
WALLS
3 57
3/4 in. Plaster or gypsum
0.0625
0.000
❑
7/18/2007 EnergyGauge FLA/COM 2004 v3.00 9