HomeMy WebLinkAbout4111 - 4121 Centerline Ln+� SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, FI.32771 / P. O. Box 1788, Sanford, Fl. 32772 (407) 302-2516 / FAX (407) 302-2526 Fire Marshal Robles Plans Review Sheet FFIC Date: 5/19/07 Business Address: 4111-4121 Centerline Lane Occ. Air Craft Hanger (interior build out) 1, 581 sq ft Corporate Hanger Type #2INEP.A. #409 Business Name: Orlando Sanford Airport /South West Ramp Contractor: Winter Park Construction Ph. (407) 644-8923 Fax. (407) 645-1972 Architect/Engineer: Eric Kuritzky Phone (407) 898-6654 Fax (407) 898-7992 Reviewed Reviewed with comment [X ] Reviewed by: Timothy Robles, Fire Marsha Comment: (Corporate Hanger #8) 1.1 Application — Construction of 1, 581 sq ft type #2 hanger with 1.2 Submittal not a T- hanger Storage Hanger Per N.F.P.A #409. 1.3 Local Sanford Fire Prevention Code 49 does not apply to hanger usage (see article #-sec-9- 11). 1.4 Two fire extinguishers required per tenant space 1-20Pound Purple "K" in plan storage area. One (1) 3A10 BC fire extinguisher required in the interior office. 1.5 Address required being 6" inches and contrasting in color. 1.6 Call (407) 302-2516 for all fire inspections E X 1 Florida Energy Efficiency Code For Building Construction Florida Department of Community Affairs EnergyGauge FLA/COM 2004 v3.00 -- Form 40OA-2004 Method A: Whole Building Performance Method for Commercial Buildings Effective December 8; 2006 PROJECT SUMMARY Short Desc: CORPORATE HANGER Description: 4111-4121 CORPORATE Owner: Addressl: SE RAMP ORLANDO SANFORD AIRPORT City: SANFORD Address2: State: FLORIDA Zip: 0 Type: Office Class: New Finished building Jurisdiction: SANFORD, SEMINOLE COUNTY, FL (691500) Cond Area: 1566 SF Cond & UnCond Area: 1566 SF No of Storeys: 1 Area entered from Plans 0 SF Permit No: 0 Max Tonnage 4 If different, write in: 5/7/2007 EnergyGauge FLA/COM 2004 v3.00 FF 10E 1 Compliance Summary Component Design. Criteria Result Gross Energy Use 1,28.0.4 1,355.7 PASSES LIGHTING CONTROLS EXTERNAL LIGHTING HVAC SYSTEM PLANT WATER HEATING SYSTEMS PIPING SYSTEMS Met all required compliance from Check List? PASSES None Entered PASSES None Entered PASSES PSSES Yes/No/NA IMPORTANT NOTE: An input report of this design building must be submitted along with this Compliance Report. 5/7/2007 EnergyGauge FLA/COM 2004 v3.00 2 CERTIFICATIONS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code Prepared By: Building Official: Date: Date: ((l % O 7 I certify that this building is in compliance with the Florida Energy Efficiency Code Owner Agent: Date: If Required by Florida law, I hereby certify (*) that the system design is in compliance with the FLorida Energy Efficiency Code Architect: Reg No: Electrical Designer: Reg No: Lighting Designer: Reg No: Mechanical Designer: Hossein Dayi Reg No: 53461 PlumbingDesigner: Hossein Da i g y Reg No: 534 (*) Signature is required where Florida Law requires design to be performed by registered design 1 professionals. Typed names and registration numbers may be used where all relevant information is contained on signed/sealed plans. 5/7/2007 EnergyGauge FLA/COM 2004 v3.00 3 Project: CORPORATE HANGER Title: 4111-4121 CORPORATE HANGER Type: Office (WEA File: Orlando.TMY) Whole Building Compliance Design Reference Total 94.44 100.00 $1,280 $1,356 ELECTRICITY(MBtu/k 94.44 100.00 Wh/$) 25404 26898 $1,280 $1,356 AREA LIGHTS 17.97 19.61 4839 5275 $244 $266 MISC EQUIPMT 12.75 12.75 3442 3442 $173 $173 PUMPS & MISC 0.11 0.11 32 32 $2 $2 SPACE COOL 21.90 20.59 5878 5534 $296 $279 VENT FANS 41.72 46.95 11213 12615 $565 $636 :redits & Penalties (if any): Modified Points: = 94.45 PASSES External bighting Compliance Description Category Allowance Area or Length ELPA CLP (W/Unit) or No. of Units (W) (W) (Sgft or ft) Il None 5/7/2007 EnergyGauge FLA/COM 2004 v3.00 4 Project: CORPORATE HANGER Title: 4111-4121 CORPORATE HANGER Type: Office (WEA File: Orlando.TMY) Lighting Controls Compliance Acronym Ashrae Description Area No. of Design Min Compli- ID (sq.ft) Tasks CP CP ance OFFICE 17 Office - Enclosed 1,566 1 3 1 PASSES PASSES Project: CORPORATE HANGER Title: 4111-4121 CORPORATE HANGER Type: Office (WEA File: Orlando.TMY) System Report Compliance A/C-1 SPLIT DX Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled < 65000 Btu/h 13.00 13.00 8.00 PASSES Cooling Capacity Air Handling Air Handler (Supply) - 0.80 0.90 PASSES System -Supply Constant Volume PASSES Plant Compliance Description Installed Size Design Min Design Min Category Comp No Eff Eff IPLV IPLV liance None 5/7/2007 EnergyGauge FLA/COM 2004 v3.00 Project: CORPORATE HANGER Title: 4111-4121 CORPORATE HANGER Type: Office (WEA File: Orlando.TMY) Water Heater Compliance Description Type Category Design Min Design Max Comp Eff Eff Loss Loss liance Water Heater 1 Electric water heater <= 12 [kW] 0.95 0.89 PASSES PASSES Project: CORPORATE HANGER Title: 4111-4121 CORPORATE HANGER Type: Office (WEA File: Orlando.TMY) Piping System Compliance Category Pipe Dia is Operating Ins Cond Ins Req Ins Compliance [inches] Runout? Temp [Btu-in/hr Thick [in] Thick [in] [F] SF.F] Heating System (Steam, Steam Condensate, & Hot Water) 0.25 False 105.00 0.28 0.75 0.50 PASSES PASSES 5/7/2007 EnergyGauge FLA/COM 2004 v3.00 Project: CORPORATE HANGER Title: 4111-4121 CORPORATE HANGER Type: Office (WEA File: Orlando.TMY) Other Required Compliance Category Section Requirement (write N/A in box if not applicable) Check Infiltration 406.1 Infiltration Criteria have been met System 407.1 HVAC Load sizing has been performed Ventilation 409.1 Ventilation criteria have been met ADS 410.1 Duct sizing and Design have been performed T & B 410.1 Testing and Balancing will be performed Motors 414.1 Motor efficiency criteria have been met Lighting 415.1 Lighting criteria have been met O & M 102.1 Operation/maintenance manual will be provided to owner Roof/Ceil 404.1 R-19 for Roof Deck with supply plenums beneath it Report 101 Input Report Print -Out from EnergyGauge F1aCom attached? 5/7/2007 EnergyGauge FLA/COM 2004 v3.00 7 EnergyGauge FLA/COM 2004 v3.00 INPUT DATA REPORT Project Information Project Name: CORPORATE HANGER Orientation: Project Title: 4111-4121 CORPORATE HANGER Building Type: Address: SE RAMP ORLANDO SANFORD AIRPORT Building Classification: State: FLORIDA No.of Storeys: Zip: 0 GrossArea: Owner: North Office New Finished building I 1566 SF Zones No Acronym Description Type Area lsfl Multiplier Total Area Isfl 1 OFFICE OFFICE CONDITIONED 1566.0 1 1566.0 [I Spaces No Acronym Description Type Depth IN Width Height Multi Total Area Iftl Iftl plier Isfl Total Volume Icfl 5/7/2007 EnergyGauge FLA/COM 2004 v3.00 In Zone: OFFICE I OFFICE OFFICE Office - Enclosed 18.00 87.00 10.00 1 1566.0 15660.0 El Lighting No Type Category No, of Watts per Power Control Type No.of Luminaires Luminaire IWI Ctrl pts In Zone: OFFICE In Space: OFFICE 1 Rece d Fl sse uorescent - General Lighting vent 1 1580 1580 Manual On/Off 3 El Walls No Description Type Width H (Effec) Multi Area DirectionConductance Heat Dens. R-Value IN IN plier [sfl (Btu/hr. sf. F] Capacity JIb/cfl Ih.sf.F/Btul Btu/sf.Fl In Zone: OFFICE 1 WALL Metal siding/2x4@24"+R1 87.00 12.00 1 1044.0 North 0.0920 1.0718 19.38 10.87 ❑ 1 Batt/5/8"Gyp 2 WALL Metal siding/2x4@24"+R 1 18.00 12.00 1 216.0 East 0.0920 1.0718 19.38 10.87 ❑ 1 Batt/5/8 "Gyp 3 WALL Metal siding/2x4@24"+R 1 87.00 12.00 1 1044.0 South 0.0920 1.0718 19.38 10.87 ❑ 1 Batt/5/8"Gyp 4 WALL 8"CMU/3/4"ISO 18.00 12.00 1 216.0 West 0.2642 9.6960 62.72 3.79 BTWN24"oc/5/8 ❑ Windows No Description Type Shaded U SHG Vis.Tr W H (Effec) Multi Total Area [Btu/hr sf F] [ft] (ft] plier ]sI'l 5/7/2007 EnergyGauge FlaCom v 2.11 2 In Zone: OFFICE In Wall: EAST WALL 1 WINDOW In Wall: NOTRH WALL I WINDOW In Wall: WEST WALL I WINDOW User Defined User Defined User Defined No No No 1.2500 0.82 1.2500 0.82 1.2500 0.82 0.76 0.76 0.76 4.00 3.00 4.00 3.00 4.00 3.00 1 4 1 12.0 48.0 12.0 Doors No Description Type Shaded? Width H (Effec) Multi Area Cond. Dens. Heat Cap. R-Value [ftJ IN plier [sfl [Btu/hr. sf. F] jib/cfl (Btu/sf. F1 Ih.sf.F/Btul In Zone: In Wall: El Roofs No Description Type Width H (Effec) Multi Area Tilt Cond. Heat Cap Dens. R-Value IN IN plier Istj [deg] (Btu/hr. Sf. F1 113tu/sf. F1 JIb/cfl [h.sf.F/Btul In Zone: OFFICE 1 ROOF Mtl Bldg Roof/R-19 87.00 18.00 1 1566.0 0.00 0.0492 1.34 9.49 20.34 Batt ❑ Skylights No Description Type U SHGC Vis.Trans W H (Effec) Multiplier Area Total Area lBtu/hr sf FJ [ft] [ft] [Sf) [SfJ In Zone: In Roof: im 5/7/2007 EnergyGauge FlaCom v 2.11 3 No Description In Zone: OFFICE 1 FLOOR Floors Type Width H (Effec) Multi Area Cond. Heat Cap. Dens. R-Value IN IN plier [sfl [Btu/hr. sf. F) [Btu/sf. F[ jib/cfl Ih.sf.F/Btul Concrete floor, 87.00 18.00 1 1566.0 0.5987 9.33 140.00 1.67 carpet and rubber pad Systems A/C-1 SPLIT DX Constant Volume Air Cooled Split System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System (Air Cooled < 65000 Btu/h Cooling 48000.00 13.00 Capacity) 8.00 2 Air Handling System -Supply (Air Handler (Supply) - 1600.00 0.80 Constant Volume) Plant Equipment Category Size Inst.No Eff. W-Heater Description 1 Electric water heater Water Heaters Capacit Cap.Unit UP Rt. 30 [Gal] 5 [kW] Efficienc 0.9500 [Ef] No. Of Units 1 Loss [Btu/h] IPLV 5/7/2007 EnergyGauge FlaCom v 2.11 4 UK 8 ON Ext-Lighting Description Category No. of Watts per Area/Len/No. of units Control T Type Wattage Luminaires Luminaire [sf/ft/No] [ W I I Ext Light I Building Entrance with (or 1 20 free standing) Canopy 7.50 Photo Sensor control 20.00 Ej Piping No Type Operating Insulation Temperature Nomonal pipe Insulation Is Runout? Conductivity Diameter Thickness IFI I Btu-in/h.sf.F) lint lint Heating System (Steam, Steam Condensate, & 105.00 0.28 Hot Wat 0.25 0.75 No Fenestration Used Name Glass Type No. of Glass SHGC VLT Conductance Panes lBtu/h.sf.Fl ASHULS91CIrAII User Defined 1 1.2500 0.8200 0.7600 Frm El Materials Used Mat No Acronym Description Only R-Value RValue Thickness Conductivity Density SpecificHeat Used lh.sf.F/Btul IN [Btu/h.ft.Fl lib/cfl lBtu/Ib.FI 187 Mat] 187 GYP OR PLAS No 0.4533 0.0417 BOARD, I /21N 0.0920 50.00 0.2000 ❑ 151 Matl151 CONC HW, DRD, 140LB, No 0.4403 0.3333 41N 0.7570 140.00 0.2000 ❑ 5/7/2007 EnergyGauge FlaCom v 2.11 5 178 Matl178 CARPET W/RUBBER PAD Yes 1.2300 105 Mat] 105 CONC BLK HW, 81N, No 1.1002 HOLLOW 269 Mat1269 .75" ISO BTWN24" oc NO 2.2321 23 Matl23 6 in. Insulation No 20.0000 4 Mat14 Steel siding No 0.0002 271 Mat1271 2x4@24" oc + RI I Batt No 10.417 94 Mat194 BUILT-UP ROOFING, NO 0.366 3366 3/81N No Name 1004 Concrete floor, carpet and rubber pad Layer Material Material No. 0.6667 0.6060 69.00 0.2000 ❑ 0.0625 0.0280 4.19 0.3000 ❑ 0.5000 0.0250 5.70 0.2000 ❑ 0.0050 26.0000 480.00 0.1000 ❑ 0.2917 0.0280 7.11 0.2000 ❑ 0.0313 0.0930 70.00 0.3500 ❑ Constructs Used Simple Massless Conductance Construct Construct [Btu/h.sEF] No No 0.60 1 151 CONC HW, DRD, 140LB, 4IN 2 178 CARPET W/RUBBER PAD No Name Simple Massless Construct Construct 1014 8"C:MU/3/4"ISO BTWN24"oc/5/8 Gyp No No Layer Material Material No. 1 105 CONC BLK HW, 81N, HOLLOW 2 269 .75 ISO BTWN24" oc 3 187 GYP OR PLAS BOARD,1/2IN Heat Capacity Density RValue [Btu/sf.F] [Ib/cf] Ih.sf.F/Btu[ 9.33 140.00 1.6703 ❑ Thickness Framing IN Factor 0.3333 0.00 ❑ 0.00 ❑ Conductance Heat Capacity Density RValue [Btu/h.sf.F) [Btu/sEF1 [Ib/cf[ [h.sEF/Btu[ 0.26 9.70 62.72 3.7856 ❑ Thickness [ft[ 0.6667 0.0625 0.0417 5/7/2007 EnergyGauge FlaCom v 2.11 Framing Factor 0.00 0.00 0.00 6 Im No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sEF[ IBtu/sf.FI [Ib/cfl Ih.sf.F/BtuI 1019 Metal siding/2x4@24"+RI]Batt/5/8"Gyp No No 0.09 1.07 19.38 10.8713 ❑ Layer Material No. Material Thickness Framing IN Factor 1 4 Steel siding 0.0050 0.00 2 271 2x4@24" oc + RI I Batt 0.2917 0.00 ❑ 3 187 GYP OR PLAS BOARD,1/2IN 0.0417 0.00 ❑ ❑ No Name Simple Construct Massless Conductance Heat Capacity Density RValue 1047 Mtl Bldg Roof/R-19 Batt Construct [Btu/h.sEF) Btu/sf.F I I Ilb/cfl [h.sf.F/Btul No No 0.05 1 34 9 49 20.3366 ❑ Layer Material Material Thickness Framing No. IN Factor 1 94 BUILT-UP ROOFING, 3/8IN 0.0313 0.00 2 23 6 in. Insulation 0.5000 0.00 ❑ 5/7/2007 EnergyGauge FlaCom v 2.11 7 PROJECT SUMMARY Short Desc: CORPORATE HANGER Owner: Addressl: SE RAMP ORLANDO SANFORD AIRPORT Address2: Description: 4111-4121 CORPORATE City: State: Zip: Type: Office Class: Jurisdiction: SANFORD, SEMINOLE COUNTY, FL (691500) Cond Area: 1566 SF Cond & UnCond Area: No of Storeys: 1 Area entered from Plans Permit No: 0 Max Tonnage If different, write in: 5/7/2007 FnergyGauge FLA/COM 2004 v3.00 SANFORD FLORIDA 0 New Finished building 1566 SF 0 SF 4 Compliance Summary Component Design Criteria Result Gross Energy Use 1,280.4 1,355.7 PASSES LIGHTING CONTROLS EXTERNAL LIGHTING HVAC SYSTEM PLANT WATER HEATING SYSTEMS PIPING SYSTEMS Met all required compliance from Check List? PASSES None Entered PASSES None Entered PASSES PALo/NA ES 'Y �, L IPORTANT NOTE: An input report of this design building must be submitted ong with this Compliance Report. 5/7/2007 EnergyGauge FLA/COM 2004 v3.00 2 CERTIFICATIONS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code Prepared By: Building Official: Date: Date: /n�� 7 I certify that this building is in compliance with the Florida Energy Efficiency Code Owner Agent: Date: If Required by Florida law, I hereby certify (") that the system design is in compliance with the FLorida Energy Efficiency Code Architect: Reg No: Electrical Designer: Reg No: Lighting Designer: Reg No: Mechanical Designer: Hossein Dayi Reg No: 53461 Plumbing Designer: Hossein Dayi Reg No: 53 (*) Signature is required where Florida Law requires design to be performed by registered design professionals. Typed names and registration numbers may be used where all relevant information is contained on signed/sealed plans. 5/7/2007 EnergyGauge FLA/COM 2004 v3.00 3 Project: CORPORATE HANGER Title: 4111-4121 CORPORATE HANGER Type: Office (WEA File: Orlando.TMY) Whole Building Compliance Design Reference Total 94.44 100.00 $1,280 $1,356 ELECTRICITY(MB A 94.44 100.00 Wh/$) 25404 26898 $1,280 $1,356 AREA LIGHTS 17.97 19.61 4839 5275 $244 $266 MISC EQUIPMT 12.75 12.75 3442 3442 $173 $173 PUMPS & MISC 0.11 0.11 32 32 $2 $2 SPACE COOL 21.90 20.59 5878 5534 $296 $2 79 VENT FANS 41.72 46.95 11213 12615 $565 $636 Credits & Penalties (if any): Modified Points: = 94.45 PASSES External Lighting Compliance Description Category Allowance Area or Length ELPA CLP (W/Unit) or No. of Units (W) (W) (Sgft or ft) None 5/7/2007 EnergyGauge FLA/COM 2004 v3.00 Project: CORPORATE HANGER Title: 4111-4121 CORPORATE HANGER Type: Office (WEA File: Orlando.TMY) Lighting Controls Compliance Acronym Ashrae Description ID Area No. of Design Min Compli- (sq.ft) Tasks CP CP ance OFFICE 17 Office - Enclosed 1,566 1 3 1 PASSES PASSES Project: CORPORATE HANGER Title: 4111-4121 CORPORATE HANGER Type: Office (WEA File: Orlando.TMY) System Report Compliance A/C-1 SPLIT DX Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled < 65000 Btu/h Cooling Capacity Air Handling Air Handler (Supply) - System -Supply Constant Volume 13.00 13.00 8.00 PASSES 0.80 0.90 PASSES PASSES Plant Compliance Description Installed Size Design Min No Eff Eff Design Min Category Comp IPLV IPLV liance None 5/7/2007 EnergyGauge FLA/COM 2004 v3.00 Project: CORPORATE HANGER Title: 4111-4121 CORPORATE HANGER Type: Office (WEA File: Orlando.TMY) Water Heater Compliance Description Type Design Min Category Design Max Comp Eff Eff Loss Loss liance Water Heater 1 Electric water heater <= 12 [kW] 0.95 0.89 PASSES PASSES Project: CORPORATE HANGER Title: 4111-4121 CORPORATE HANGER Type: Office (WEA File: Orlando.TMY) Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance [inches] Runout? Temp [Btu-in/hr Thick [in] Thick [in] [F] SF.F] Heating System (Steam, Steam 0.25 False 105.00 0.28 0.75 0.50 PASSES Condensate, & Hot Water) PASSES 5/7/2007 EnergyGauge FLA/COM 2004 v3.00 Project: CORPORATE HANGER Title: 4111-4121 CORPORATE HANGER Type: Office (WEA File: Orlando.TMY) Other Required Compliance Category Section Requirement (write N/A in box if not applicable) Check Infiltration 406.1 Infiltration Criteria have been met System 407.1 HVAC Load sizing has been performed Ventilation 409.1 Ventilation criteria have been met ADS 410.1 Duct sizing and Design have been performed T & B 410.1 Testing and Balancing will be performed Motors 414.1 Motor efficiency criteria have been met Lighting 415.1 Lighting criteria have been met O & M 102.1 Operation/maintenance manual will be provided to owner Er I Roof/Ceil 404.1 R-19 for Roof Deck with supply plenums beneath it Report 10] Input Report Print -Out from EnergyGauge FlaCom attached? rv-l/ 5/7/2007 EnergyGauge FLA/COM 2004 v3.00 7 EnergyGauge FLA/COM 2004 v3.00 INPUT DATA REPORT Project Name: CORPORATE HANGER Project Information Orientation: North Project Title: 4111-4121 CORPORATE HANGER Building Type: Office Address: SE RAMP ORLANDO SANFORD AIRPORT Building Classification: New Finished buildinsz State: FLORIDA Zip: 0 Owner: No.of Storeys: I GrossArea: 1566 SF Zones No Acronym Description Type Area [sq Multiplier Total Area [sfl 1 OFFICE OFFICE CONDITIONED 1566.0 1 1566.0 ❑ Spaces No Acronym Description Type Depth [ftl Width Height Multi IN [ft] plier Total Area [sfJ Total Volume [cfJ 5/7/2007 EnergyGauge FLA/COM 2004 v3.00 1 In Zone: OFFICE 1 OFFICE OFFICE Office - Enclosed 18.00 87.00 10.00 1 1566.0 15660.0 Lighting No Type Category No. of Luminaires Watts per Luminaire Power [WI Control Type No.of Ctrl pts In Zone: OFFICE In Space: OFFICE 1 Recessed Fluorescent - General Lighting No vent 1 1580 1580 Manual On/Off 3 Walls No Description Type Width H (Effec) Multi [ft] [ft] plier Area DirectionConductance [sf] [Btu/hr. sf. F] Heat Capacity Dens. R-Value [Ib/cf[ [h.sf.F/Btu) [Btu/sf.F[ In Zone: OFFICE 1 WALL Metal 87.00 siding/2x4@24"+R 1 12.00 1 1044.0 North 0.0920 1.0718 19.38 10.87 l Batt/5/8"Gyp 2 WALL Metal 18.00 siding/2x4@24"+R 1 12.00 1 216.0 East 0.0920 1.0718 19.38 10.87 1 Batt/5/8"Gyp 3 WALL Metal 87.00 siding/2x4@24"+R 1 12.00 1 1044.0 South 0.0920 1.0718 19.38 10.87 1 Batt/5/8"Gyp 4 WALL 8"CMU/3/4"ISO 18.00 13TWN24"oc/5/8 12.00 1 216.0 West 0.2642 9.6960 62.72 3.79 Gyp Windows No Description Type Shaded U SHG Vis.Tr W H (Effec) Multi Total Area [Btu/hr sf F] IN [ft] plier [sf] 5/7/2007 EnergyGauge FlaCom v 2.11 In Zone: OFFICE In Wall: EAST WALL 1 WINDOW User Defined No 1.2500 0.82 0.76 4.00 3.00 1 12.0 ❑ In Wall: NOTRH WALL 1 WINDOW User Defined No 1.2500 0.82 0.76 4.00 3.00 4 48.0 El Wall: WEST WALL I WINDOW User Defined No 1.2500 0.82 0.76 4.00 3.00 1 12.0 ❑ Doors No Description Type Shaded? Width H (Effec) Multi Area Cond. Dens. Heat Cap. R-Value IN [ft] plier [sf[ [Btu/hr. sf. F] [Ib/cf[ [Btu/sf. F[ [h.sf.F/Btu[ In Zone: In Wall: El Roofs No Description Type Width H (Effec) Multi Area Tilt Cond. Heat Cap Dens. R-Value IN IN plier [sf[ [deg] [Btu/hr. SE F] [Btu/sf. F[ [Ib/cf] (h.sf.F/Btu] In Zone: OFFICE I ROOF Mtl Bldg Roof/R-19 87.00 18.00 1 1566.0 0.00 0.0492 1.34 9.49 20.34 ❑ Batt Skylights No Description Type U SHGC Vis.Trans W H (Effec) Multiplier Area Total Area [Btu/hr sf F] IN IN [S11 [Sf] In Zone: In Roof: 5/7/2007 EnergyGauge FlaCom v 2.11 Floors No Description Type Width IN H (Effec) Multi [ftl plier Area Cond. Heat Cap. [sfl [Btu/hr. sE F] [Btu/sE Ff Dens. R-Value jlb/cf[ [h.sf.F/Btu) In Zone: OFFICE 1 FLOOR Concrete floor, 87.00 carpet and rubber pad 18.00 1 1566.0 0.5987 9.33 140.00 1.67 Systems A/C-1 SPLIT DX Constant Volume Air Cooled Split System < 65000 Btu/hr No. Of Units 1 Component Category Capacity Efficiency IPLV I Cooling System (Air Cooled < 65000 Btu/h Cooling Capacity) 2 Air Handling System -Supply (Air Handler (Supply) - Constant Volume) 48000.00 1600.00 13.00 8.00 0.80 Equipment Category Plant Size Inst.No Eff. IPLV Water Heaters W-Heater Description Capacit Cap.Unit I/P Rt. Efficienc Loss I Electric water heater 30 [Gal] 5 [kW] 0.9500 [Ef] [Btu/h] ❑ 5/7/2007 EnergyGauge FlaCom v 2.11 Ext-Lighting Description Category No. of Watts per Area/Len/No. of units Control Type Wattage Luminaires Luminaire [sf/ft/Noj [WI 1 Ext Light I Building Entrance with (or 1 20 7.50 Photo Sensor control 20.00 ❑ free standing) Canopy Piping No Type yp Operating Insulation Nomonal pipe Insulation Is Runout? Temperature Conductivity Diameter Thickness [F[ [ Btu-in/h.sf.F] [in[ [in[ I Heating System (Steam, Steam Condensate, & 105.00 0.28 0.25 0.75 No El Wat Fenestration Used Name Glass Type No. of Glass SHGC Conductance VLT Panes [Btu/h.sf.F[ ASHULSg1CIrAll User Defined 1 1.2500 0.8200 0.7600 ❑ Frm Materials Used Mat No Acronym Description Only R-Value RValue Thickness Conductivity Density SpecificHeat Used [h.sf.FBtul A [Btu/h.ft.F[ [lb/cf[ [Btu/Ib.F] 187 Matl187 GYP OR PLAS No 0.4533 0.0417 0.0920 50.00 0.2000 ❑ BOARD,1 /21N 151 Matl151 CONC HW, DRD, 140LB, No 0.4403 0.3333 0.7570 140.00 0.2000 ❑ 41N 5/7/2007 EnergyGauge FlaCom v 2.11 5 178 Mat] 178 CARPET W/RUBBER PAD Yes 1.2300 105 Matl105 CONC BLK HW, 81N, No 1.1002 0.6667 0.6060 69.00 ❑ HOLLOW 0.2000 ❑ 269 Mat1269 .75" ISO BTWN24" oc No 2.2321 0.0625 0.0280 4.19 0.3000 ❑ 23 Mat123 6 in. Insulation No 20.0000 0.5000 0.0250 5.70 0.2000 ❑ 4 Matl4 Steel siding No 0.0002 0.0050 26.0000 480.00 0.1000 ❑ 271 Mat1271 2x4@24" oc + RI I Batt No 10.4179 0.2917 0.0280 7. l 1 0.2000 ❑ 94 Matl94 BUILT-UP ROOFING, No 0.3366 0.0313 0.0930 70.00 0.3500 El Constructs Used No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.Fl [Ib/cfl [h.sLF/Btul 1004 Concrete floor, carpet and rubber pad No No 0.60 9.33 140.00 1.6703 ❑ Layer Material Material Thickness Framing No. [ftl Factor 1 151 CONC HW, DRD, 140LB, 4IN 0.3333 0.00 ❑ 2 178 CARPET W/RUBBER PAD 0.00 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F[ [Btu/sf.Fl [lb/cfl [h.sf.F/Btu) 1014 8"CMU/3/4"ISO BTWN24"oc/5/8 Gyp No No 0.26 9.70 62.72 3.7856 ❑ Layer Material Material No. 1 105 CONC BLK HW, 81N, HOLLOW 2 269 .75" ISO BTWN24" oc 3 187 GYP OR PLAS BOARD, 1/2 IN Thickness Framing [fti Factor 0.6667 0.00 ❑ 0.0625 0.00 ❑ 0.0417 0.00 ❑ 5/7/2007 EnergyGauge FlaCom v 2.11 6 I No Name Simple Massless Construct Construct 1019 Metal siding/2x4@24"+Rl 1 Batt/5/8°Gyp No No L M Conductance Heat Capacity Density RValue (Btu/h.sf.F] jBtu/sfFj jib/cfj (h.sf.F/Btu] 0.09 1.07 19.38 10.8713 ❑ ayer aterial Material Thickness Framing No. IN Factor 1 4 Steel siding 0.0050 0.00 ❑ 2 271 2x4@24" oc + RI I Batt 0.2917 0.00 ❑ 3 187 GYP OR PLAS BOARD,1/2IN 0.0417 0.00 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct jBtu/h.sLF] [Btu/sf.Fj jib/cfj (h.sf.F/Btu] 1047 Mtl Bldg Roof/R-19 Batt No No 0.05 1.34 9.49 20.3366 ❑ Layer Material Material Thickness Framing No. IN Factor 1 94 BUILT-UP ROOFING, 3/8IN 0.0313 0.00 ❑ 2 23 6 in. Insulation 0.5000 0.00 ❑ 5/7/2007 EnergyGauge FlaCom v 2.11 7