Loading...
HomeMy WebLinkAbout3993 - 3999 W 1 St0010 0 M, SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772 (407 302-2520 / FAX (407) 330-5677 Pager (407) 918-0395 Plans Review Sheet Date: April 21, 2004 Business Address: 3991 West First Street Occ. Ch. 38 Business Business Name: Kampf Title Ph. ( ) Contractor: Wiginton Fire Protection Ph. (407) 831-3414 FAX (407) 831-5740 Reviewed [ J Revrewed wlth comment„[ X ] Rejected [ ] Reviewed by: Timothy Robles, Fire Protection InspectoL-K— Comment: Instillation of 114 new wet heads, one ( 1) type of head L l Application — Per N.F.P.A. #13-1999 ed, Design area, Light Hazard office 1.2 114 Tyco Model TY-FBR Size V2 inch K- 5.6 @ '/2" >155 degree heads Tamper switches required on all outside and inside fire sprinkler valves, including outside Backflow Prevention valves. • Two (2) hour hydro and spacing test required. • Please have installer available at time of final inspection • Under ground work includes 5' (ft) of under ground • Hydro and flush required on under ground 1 SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772 (407 302-2520 / FAX (407) 330-5677 Pager (407) 918-0395 Plans Review Sheet Date: March 24, 2004 Business Address: 3999 West First Street Occ. Ch. Business Occupancy 38 Business Name: Kempf Title Contractor: McKee Construction Architect: Architectural Dynamics Ph. () FAX () Ph. (407) 323-1150 FAX (407) 323-9304 Reviewed [] Ke�leweCl Wlth CO11] rilelltXRejected [] Reviewed by: Timothy Robles, Fire Protection Inspector/plans Examiner Comment: Plans reviewed as Business Occupancy. FD reserves right to require applicable code requirements if occupancy use changes. Sprinkler System require per local city ordinance. Fire sprinkler system shall be monitored per City of Sanford local ordinance. Fire sprinkler contractor to submit design criteria for sprinkler system. Fire alarm system may be required to have horn strobes and pull stations through -out, (depending on amount of employee's) 1.1 Application — New Building. 11,250 sq. ft. , Type IV- fire sprinkler protected 1.2 Mixed — N/A 1.3 Special Definitions — Meets F.F.P.C.- 6.1.11.1 (Record keeping/Business transactions). 1.40assification of Occupancy — Business F.F.P. C. 1.5 Classification of Hazard of Contents — Ordinary/6.2.2.2. * 1.6 Minimum Construction — N/R 2.2 Means of Egress Components — 2.3 Capacity of Egress — One person per 100 sq ft (50 or more occupants shall comply with 44' isle ways) 1 SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772 (407 302-2520 / FAX (407) 330-5677 Pager (407) 918-0395 2.4 Number of Exits — O.K. 2.5 Arrangement of Egress — Two separate EXITS 2.6 Travel Distance — O.K., Does not exceed 93' ft 6" inches 2.7 Discharge from Exits — O.K., will field verify 2.8 Illumination of Means of Egress — O.K.; will field verify 2.9 Emergency Lighting =0k, will field verify 2.10 Marking of Means of Egress — O.K.; will field verify 2.11 Special Features —N/A 3.1 Protection of Vertical Openings - Shall be constructed as a smoke barrier with degree of compartments 3.2 Protection from Hazards — N/N 3.3 Interior Finish - Class "A "or 'T " 3.4 Detection, Alarm and Communications Systems Required fire sprinkler monitoring per City Fire Code 3.5 Extinguishing Requirements — as per NFPA 10 — Three (3) 3A rated fire extinguishers required in this building mounted approved cabinet one (1) 5 pound CO 2c fire extinguisher required in SERVICE ROOM. (See blue prints) 3.6 Corridors — Rated wall required between buildings. One -hour fire rated corridors (exception Fire Sprinkler System) - 4 Special Provisions - 5 Building Services 5.1 Utilities — Additional fire hydrant required per L.D.R. (250' FT from principle building) 5.2 HVAC - shall comply with N.F.P.A. # 90 A & 990B over 2000 C.F.M. duct detectors required (blue prints show none over 1,200 c.f. m) 5.3 Elevators, Escalators, Conveyors: 5.4 Rubbish Chutes, Incinerators, and Laundry Chutes — N/A 2 SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, FI. 32771 / P. O. Box 1788, Sanford, Fl. 32772 (407 302-2520 / FAX (407) 330-5677 Pager (407) 918-0395 Sanford City Code — Chapter 9 Fire Sprinklers: blue prints required; Monitoring: Required by a U.L. listed Central Station for all mandated fire Sprinklered properties, per city code chapter #9 Other: NFPA 1 3-5.1 Fire Lanes — Not Required 3-6.1 Key Box - Required; will field veri , see application, and see blue prints for location 3-7.1 Bldg. Address Number Posted and Legible - Required; will field veri , see blue print for visible location 3 ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs EnergyGauge F1aCom v1.22 FORM 40OA-2001 NVhole Building Performance Method for Commercial Buildings Jurisdiction: SANFORD, SEMINOLE COUNTY, FL (691500) Short Desc: 200406 Project: KAMPF TITLE & GUARANTY CORP. Owner: KAMPF TITLE & GUARANTY CORP. Address: City: SANFORD State: FLORIDA PermitNo: 0 Zip: 0 Storeys: 1 Type: Office (Business) GrossArea: 10696 Class: New Finished building Net Area: 10696 Max Tonnage: 10 (if different, write in) Compliance Summary Component Design Criteria Result Gross Energy Use 64.22 100.00 PASSES Other Envelope Requirements - A PASSES LIGHTING CONTROLS EXTERNAL LIGHTING HVAC SYSTEM PLANT WATER HEATING SYSTEMS PIPING SYSTEMS Met all required compliance from Check List? PASSES PASSES PASSES PASSES PASSES PASSES es o/NA IMPORTANT NOTE: An input report Print -Out from EnergyGauge FlaCom of this design building must be submitted along with this Compliance Report. 2/17/2004 EnergyGauge F1aCom FLCCSB v1.22 1 COMPLIANCE CERTIFICATION: I hereby certify that the plans and Review of the plans and specifications covered by this specifications covered by this calculation are calculation indicates compliance with the Florida Energy in compliance with the Florida Energy Code. Before construction is completed, this building will be Efficiency Code. inspected for compliance in accordance with Section 553.908, F.S. PREPARED BY: DON WILSON, P.E. BUILDING OFFICIAL: DATE: Z / 2 '0 ¢ DATE: 1 hereby certify that this building is in compliance with the Florida Energy Efficiency Code. OWNER AGENT* DATE: ff required by Florida taw, t Hereby certify (•) that the system design is in compliance with the Florida Energy Code. REGISTRATION No. ARCHITECT: ELECTRICAL SYSTEM DESIGNER: -LIGHTING SYSTEM RESIGNER: MECHANICAL SYSTEM DESIGNER: DON WILSON, P.E. F(I 33�� ' PLUMBING SYSTEM DESIGNER: () Signature is required where Florida Law requires design to be -performed by registered design.professionals. Typed names and registration numbers may be used where all relevant information is contained on signed/sealed plans. 2/17/2004 EnergyGauge FlaCom FLCCSB 0.22 Project: 200406 Title: KAMPF TITLE & GUARANTY CORP. Type: Office (Business) Location: SANFORD, SEMINOLE COUNTY, FL (691500) (WEA File: Orlando.TMY Whole Building Compliance II Total Design 64.22 Reference 100.00 ELECTRICITY 64.22 100.00 AREA LIGHTS 18.90 22.91 MISC EQUIPMT 8.18 8.18 PUMPS & MISC 0.03 0.03 SPACE COOL 14.57 23.52 SPACE HEAT 2.51 1.30 VENT FANS 20.03 44.04 :redits &Penalties (if any): Modified Points: = 64.22 PASSES 2/17/2004 EnergyGauge FlaCom FLCCSB v1.22 3 Project: 200406 Title: KAMPF TITLE & GUARANTY CORP. Type: Office (Business) Location: SANFORD, SEMINOLE COUNTY, FL (691500) (WEA File: Orlando.TMY Other Envelope Requirements Item Zone Description Design Limit Meet Req. 200406Zo 1 Rfl 200406Zo 1 Exterior Roof - Max Uo Limit 0.04 0.09 Yes 200406Zo2Rfl 200406Zo2 Exterior Roof - Max Uo Limit 0.04 0.09 Yes 200406Zo3Rfl 200406Zo3 Exterior Roof - Max Uo Limit 0.04 0.09 Yes Meets Other Envelope Requirements External Lighting Compliance Description Category Allowance Area or Length ELPA CLP (W/Unit) or No. of Units (W) (W) {Sgft or ft) None 411 Project: 200406 Title: KAMPF TITLE & GUARANTY CORP. Type: Office (Business) Location: SANFORD, SEMINOLE COUNTY, FL (691500) (WEA File: Orlando.TMY Lighting Controls Compliance Acronym Ashrae Description Area No. of Design Min Compli- ID (sq.ft) Tasks CP CP ance 200406Zo1Spl 28 Offices (Partitions>4.5 ft below 4,000 1 21 5 PASSES ceiling) Enclosed offices, all open plan offices without partitions 200406Zo2Spl 28 Offices (Partitions>4.5 ft below 1,320 1 6 2 PASSES ceiling) Enclosed offices, all open plan offices without partitions 200406Zo3Spl 28 Offices (Partitions>4.5 ft below 5,376 1 30 7 PASSES ceiling) Enclosed offices, all open plan offices without partitions I PASSES 2/17/2004 EnergyGauge F1aCom FLCCSB v1.22 Project: 200406 Title: KAMPF TITLE & GUARANTY CORP. Type: Office (Business) Location: SANFORD, SEMINOLE COUNTY, FL (691500) (WEA File: Orlando.TMY System Report Compliance 200406Sy1 System 1 Constant Volume Packaged No. of Units System 2 Component Category Capacity .Design Eff -Resign IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled 65000 to 135000 9.90 8.90 8.30 8.30 PASSES Btu/h Cooling Capacity Heating System Electric Furnace 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 0.37 0.80 PASSES System -Supply Constant Volume Air Distribution ADS System 6.00 4.20 PASSES System 200406Sy2 System 2 .Constant VolumeAir Cooled No. -of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled < 65000 Btu/h 10.00 10.00 8.00 PASSES Cooling Capacity Heating System Electric Furnace 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 0.28 0.80 PASSES System -Supply Constant Volume Air Distribution ADS System 6.00 4.20 PASSES Systcm 200406Sy3 System 3 Constant Volume Packaged No. of Units System 2 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled 65000 to 135000 10.10 8.90 8.30 8.30 PASSES Btu/h Cooling Capacity Heating System Electric Furnace 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 0.38 0.80 PASSES System -Supply Constant Volume PASSES 2/17/2004 EnergyGauge FlaCom FLCCSB vl.22 Plant Compliance Description Installed Size Design Min Design. Min No Eff Eff IPLV IPLV Category Comp liance None Water Heater Compliance Description Type Category Design Eff Min Design Max Comp Eff Loss Loss liance None Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance [inches] Runout? Temp [Btu-in/hr Thick [in] Thick [in] [F] .SF.F] None 2/17/2004 EnerZVGauge F1aCom FLCCSB vI.22 -t: 200406 KAMPF TITLE & GUARANTY CORP. Office (Business) ion: SANFORD, SE Other Required Compliance Category Section Requirement (write N/A in box if not applicable) Check Infiltration 406.1 Infiltration Criteria have been met ©- System 407.1 HVAC Load sizing has been performed Ventilation 409.1 Ventilation criteria have been met D ADS 410.1 Duct sizing and Design have been performed T & B 410.1 Testing and Balancing will be performed Electrical 413.1 Metering criteria have been met ED Motors 414.1 Motor efficiency criteria have been met Lighting 415.1 Lighting criteria have been met O & M 102.1 Operation/maintenance manual will be provided to owner Roof/Ceil 404.1 R-19 for Roof Deck with supply plenums beneath it Report 101 Input Report Print -Out from EnergyGauge FlaCom attached? Er I 2/ 17/2004 EnergyGauge F1aCom FLCCSB v1.22 7 ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs E,nergyGauge FlaCom v1.22 INPUT DATA REPORT Project Information Project Name: 200406 Project Title: KAMPF TITLE & GUARANTY CORP. Address: Orientation: North Building Type: Office (Business) Building Classification: New Finished building State: FLORIDA No.of Storeys: 1 Zip: 0 GrossArea: 10696 Owner: KAMPF TITLE & GUARANTY C Zones No Acronym Description Type Load Profile Area Multiplier Total Area [sfl [sfl 1 200406Zol Zone 1 CONDITIONED Uses Building Load 4000.0 1 4000.0 ❑ Profile 2 200406Zo2 Zone 2 CONDITIONED Uses Building Load 1320.0 1 1320.0 ❑ Profile 3 200406Zo3 Zone 3 CONDITIONED Uses Building Load 5376.0 1 5376.0 ❑ Profile 2/17/2004 EnergyGauge FlaCom FLCCSB v1.22 1 Spaces No Acronym Description Type Depth. Width Height Multi Total Area Total Volume [ft] IN [ft] plier [sf] [cf] In Zone: 200406Zol 1 200406Zo1Sp Zo0Spl Offices (Partitions>4.5 ft 80.00 50.00 14.00 1 4000.0 56000.0 El below ceiling) Enclosed offices, all open plan offices without partitions In Zone: 200406Zo2 1 200406Zo2Sp Zo0Sp1 Offices (Partitions>4.5 ft 22.00 60.00 14.00 1 1320.0 18480.0 [l below ceiling) Enclosed offices, all open plan offices without partitions In Zone: 200406Zo3 1 200406Zo3Sp Zo0Spl Offices (Partitions>4.5 ft 56.00 96.00 14.00 1 5376.0 75264.0 El below ceiling) Enclosed offices, all open plan offices without partitions Lighting No Type Power Control Type No.of [W] Ctrl pts In Zone: 200406Zol In Space: 200406Zo1Spl 1 Recessed Fluorescent - No vent 7200.00 Manual On/Off 21 [] In Zone: 200406Zo2 In Space: 200406Zo2Sp1 1 Recessed Fluorescent - No vent 1824.00 Manual On/Off 6 El In Zone: 200406Zo3 In Space: 200406Zo3Sp1 1 Recessed Fluorescent - No vent 9504.00 Manual On/Off 30 [] 2/17/2004 EnergyGauge FlaConn FLCCSB vl.22 Walls No Description Type Width H (Effec) Multi Area DirectionConductance Heat Dens. R-Value IN [ft] plier [sf] [Btu/hr. sf. F] Capacity [lb/cf] [h.sf.FBtu] In Zone: 200406Zo1 1 200406Zo1Wal 5/8" stucco 50.00 14.00 1 700.0 North 0.2067 5.7314 34.65 4.84 /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 2 200406Zo1Wa2 5/8" stucco 80.00 14.00 1 1120.0 East 0.2067 5.7314 34.65 4.84 /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 3 200406Zol Wa3 5/8" stucco 50.00 14.00 1 700.0 South 0.2067 5.7314 34.65 4.84 /8"CMU/3/4"ISO 13TWN24"oc/.5" Gyp In Zone: 200406Zo2 1 200406Zo2Wal 5/8" stucco 16.00 14.00 1 224.0 East 0.2067 5.7314 34.65 4.84 /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 2 200406Zo2Wa2 5/8" stucco 22.00 14.00 1 308.0 South 0.2067 5.7314 34.65 4.84 /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp In Zone: 200406Zo3 1 PrOZo3Wa1 5/8" stucco 75.00 14.00 1 1050.0 North 0.2067 5.7314 34.65 4.84 ❑ /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 2 200406Zo3Wa2 5/8" stucco 96.00 14.00 1 1344.0 West 0.2067 5.7314 34.65 4.84 /8"CMU/3/4"ISO 13TWN24"oc/.5" Gyp 3 200406Zo3Wa3 5/8" stucco 56.00 14.00 1 784.0 South 0.2067 5.7314 34.65 4.84 /8"CMU/3/4"ISO 13TWN24"oc/.5" Gyp 2/17/2004 EnergyGauge FlaCom FLCCSB 0.22 3 Windows No Description Type Shaded UCen SC Vis.Tr W H (Effec) Multi Total Area [Btu/hr sf F] [ft] [ft] plier [sf] In Zone: 200406Zol In Wall: 200406Zo1Wal 1 200406Zo 1 Wal Wi SINGLE REF B No 0.8785 0.26 0.05 3.50 6.50 7 159.3 FJ 1 TINT-L In Wall: 200406Zo1Wa2 1 200406Zo 1 Wa2Wi SINGLE REF B No 0.8785 0.26 0.05 3.50 6.50 10 227.5 1 TINT-L In Wall: 200406Zo1Wa3 1 200406Zo 1 Wa3 Wi SINGLE REF B No 0.8785 0.26 0.05 3.50 6.50 2 45.5 1 TINT-L In Zone: 200406Zo2 In Wall: 200406Zo2Wal 1 200406Zo2Wa1 WiSINGLE REF B No 0.8785 0.26 0.05 3.50 6.50 1 22.8 1 TINT-L In Wall: 200406Zo2Wa2 1 200406Zo2Wa2WiSINGLE REF B No 0.8785 0.26 0.05 3.50 6.50 2 45.5 1 TINT-L In Zone: 200406Zo3 In Wall: 200406Zo3Wa1 1 200406Zo3Wa1WiSINGLE REF B No 0.8785 0.26 0.05 3.50 6.50 11 250.3 1 TINT-L In Wall: 200406Zo3Wa2 1 200406Zo3Wa2WiSING1'-E REF B No 0.8785 0.26 0.05 3.50 6.50 8 182.0 1 TINT-L In Wall: 200406Zo3Wa3 1 200406Zo3Wa3WiSINGLE REF B No 0.8785 0.26 0.05 3.50 6.50 3 68.3 1 TINT-L Doors No Description. Type Shaded? Width H (Effec) Multi Area Cond. Dens. Heat Cap. R-Value IN [ft] plier [sf] [Btu/hr. sf. F] [lb/cf] [Btu/sf. F] [h.s£F/Btu] In Zone: In Wall: 2/17/2004 EnergyGauge F1aCom FLCCSB v1.22 Roofs No Description Type Width H (Effec) Multi Area Tilt Cond. Heat Cap Dens. R-Value IN [ft] plier [sf] [deg] [Btu/hr. SE F] [Btu/sf. F] [lb/cf] [h.sf.FBtu] In Zone: 200406Zo1 1 200406Zo1Rfl Sngl Ply/2"Iso/Mtl 50.00 80.00 1 4000.0 0.00 0.0369 0.64 4.77 27.12 ❑ Deck/6"BATT In Zone: 200406Zo2 1 200406Zo2Rfl Sngl Ply/2"Iso/Mtl 60.00 22.00 1 1320.0 0.00 0.0369 0.64 4.77 27.12 ❑ Deck/6"BAT'r In Zone: 200406Zo3 1 200406Zo3Rfl Sngl Ply/2"Iso/Mtl 56.00 96.00 1 5376.0 0.00 0.0369 0.64 4.77 27.12 ❑ Deck/6"BAT'C Skylights No Description Type UCen Shading Vis.Trans W H (Effec) Multiplier Area Total Area [Btu/hr sf F] Coeff IN [ft] [Sf] [sf] In Zone: In Roof: El Floors No Description Type Width H (Effec) Multi Area Cond. Heat Cap. Dens. R-Value IN [ft] plier [sf] [Btu/hr. sf. F] [Btu/sf. F] [lb/cf] [h.sf.FBtu] In Zone: 200406Zo1 1 200406Zo1F11 Concrete floor, 50.00 80.00 1 4000.0 0.5987 9.33 140.00 1.67 ❑ carpet and rubber pad In Zone: 200406Zo2 2/17/2004 EnergyGauge F1aCom FLCCSB v1.22 I 200406Zo2F11 Concrete floor, 60.00 22.00 1 1320.0 0.5987 9.33 140.00 1.67 0 carpet and rubber pad In Zone: 200406Zo3 1 200406Zo3F11 Concrete floor, 56.00 96.00 1 5376.0 0.5987 9.33 140.00 1.67 �] carpet and rubber pad Systems 200406Syl System 1 Constant Volume Packaged System No. Of Units 2 Component Category Capacity Efficiency IPLV i Cooling System (Air Cooled 65000 to 135000 Btu/h 91000.00 9.90 8.30 Cooling Capacity) 2 Heating System (Electric Furnace) 38385.00 1.00 3 Air Handling System -Supply (Air Handler (Supply) - 3000.00 0.37 Constant Volume) 4 Air Distribution System (ADS System) 6.00 ❑ 200406Sy2 System 2 Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System (Air Cooled < 65000 Btu/h Cooling 58000.00 10.,00 8.00 Capacity) 2 Heating System (Electric Furnace) 33984.00 1.00 3 Air Handling System -Supply (Air Handler (Supply) - 2000.00 0.28 El Constant Volume) 4 Air Distribution System (ADS System) 6.00 El 2/17/2004 EnergyGauge F1aCom FLCCSB v1.22 6 200406Sy3 System 3 Constant Volume Packaged System No. Of Units 2 Component Category Capacity Efficiency IPLV 1 2 3 Cooling System (Air Cooled 65000 to 135000 Btu/h Cooling Capacity) Heating System (Electric Furnace) Air Handling System -Supply (Air Handler (Supply) - Constant Volume) 122000.00 38385.00 4000.00 10.10 8.30 1.00 0.38 ❑ ❑ Plant Equipment Category Size Inst.No Eff. IPLV Water Heaters W-Heater Description Capacit Cap.Unit I/P Rt. Efficienc Loss Ext-Lighting Description Categories. Area/Len/No. of units [sf/ft/No] Wattage [W] Piping No Type Operating Insulation Temperature Conductivity [F] [ Btu-in/h.sf.F] Nomonal pipe Diameter [in] Insulation. Is Runout? Thickness [in] 2/17/2004 EnergyGauge FlaCom FLCCSB v1.22 Fenestration Used Name Glass Type No. of Glass SC VLT Frame Frame Panes Conductance Conductance Absorptance [Btu/h.sf.F] [Btu/h.sf.F] ApLbWnd4 SINGLE REF B 1 0.8785 0.2600 0.0500 0.4340 0.7000 ❑ TINT-L Materials Used Only R-Value RValue Thickness Conductivity Density SpecificHeat Mat No Acronym Description Used [h.sLF/Btu] IN [Btu/h.ft.Fl [Ib/cf] [Btu/Ib.F] 18 Mad18 2 in. Wood No 2.3857 0.1670 0.0700 37.00 0.3900 ❑ 264 Ma1.1264 ALUMINUM, 1/16IN No 0.0002 0.0050 26.0000 480.00 0.1000 0 214 Mat1214 POLYSTYRENE, EXP., No 5.2100 0. 10 42- 0.0200 1.80 0.2900 ❑ 1-1/4IN, 187 Mat1187 GYP OR PLAS No 0.4533 0.0417 0.0920 50.00 0.2000 ❑ BOARD,1 /2IN 206 Mat1206 CELLULOSE,FILL,5.5IN,R- No 20.8318 0.4583 0.0220 3.00 0.3300 ❑ 20 151 Mad151 CONC HW, DRD, 140LB, No 0.4403 0.3333 0.7570 140.00 0.2000 ❑ 4IN 178 Mat1178 CARPET W/RUBBER PAD Yes 1.2300 ❑ 265 Matl265 Soil., 1 ft No 2.0000 1.0000 0.5000 100.00 0.2000 ❑ 48 Mat148 6 in. Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000 ❑ 123 Mat1123 CONC BLOCK No 1.7227 0.6667 0.3870 53.00 0.2000 ❑ MW,8IN,HOLLOW 159 Mat1159 CONC No 0.3202 0.3333 1.0410 140.00 0.2000 ❑ HW-UNDRD-140LB-41N 57 Mat157 3/4 in. Plaster or gypsum No 0.1488 0.0625 0.4200 100.00 0.2000 ❑ 72 Mat172 AIR LAYER, 3/41N OR Yes 0.9000 ❑ LESS, VERT. WALLS 267 Mat1267 0.75" stucco No 0.1563 0.0625 0.4000 16.00 0.2000 ❑ 2/17/2004 EnergyGauge FlaCom FLCCSB v1.22 8 266 Mat1266 2x4@16" oc + RI 1 Batt No 8.3343 0.2917 0.0350 9.70 0.2000 ❑ 215 Mat1215 POLYSTYRENE, EXP., No 8.3350 0.1667 0.0200 1.80 0.2900 ❑ 2IN, 105 Mat1105 CONC BLK HW, 8IN, No 1.1002 0.6667 0.6060 69.00 0.2000 ❑ HOLLOW 256 Mat1256 WOOD, SOFT, 1-1/21N No 1.8939 0.1250 0.0660 32.00 0.3300 ❑ 268 Mat1268 0.625" stucco No 0.1302 0.0521 0.4000 16.00 0.2000 ❑ 42 Mat142 8 in. Lightweight concrete No 2.0212 0.6670 0.3300 38.00 0.2000 ❑ block 269 Mat1269 .75" ISO BTWN24" oc No 2.2321 0.0625 0.0280 4.19 0.3000 ❑ 86 Mat186 BRICK, COMMON, 41N No 0.8012 0.3333 0.4160 120.00 0.2000 ❑ 211 Matl2ll POLYSTYRENE,EXP.,1/21 No 2.0850 0.0417 0.0200 1.80 0.2900 ❑ N, 12 Mad 12 3 in. Insulation No 10.0000 0.2500 0.0250 2.00 0.2000 ❑ 218 Mat1218 POLYURETHANE,EXP.,1/2 No 3.2077 0.0417 0.0130 1.50 0.3800 ❑ IN, 23 Mat123 6 in. Insulation No 20.0000 0.5000 0.0250 5.70 0.2000 ❑ 4 Mat14 Steel siding No 0.0002 0.0050 26.0000 480.00 0.1000 ❑ 271 Mat1271 2x4@24" oc + RI 1 Batt No 10.4179 0.2917 0.0280 7.11 0.2000 ❑ 272 Mat1272 Panel with 7/16" panels Yes 0.9044 ❑ 273 Mat1273 Hollow core flush (1.375") Yes 1.2777 ❑ 274 Mat1274 Solid core flush (1.375") Yes 1.7141 ❑ 275 Mat1275 Panel with 7/16" panels Yes 1.0019 ❑ (1.375") 276 Mat1276 Hollow core flush (1.75") Yes 1.3239 ❑ 277 Mat1277 Panel with 1-1/8" panels Yes 1.7141 ❑ (1.75") 278 Mat1278 Solid core flush (1.75") Yes 1.6500 ❑ 279 Mat1279 Solid core flush (2.25") Yes 2.8537 ❑ 280 Mat1280 Fiberglass/Mineral wool core Yes 0.8167 ❑ 281 Mat1281 Paper Honeycomb core Yes 0.9357 ❑ 282 Mat1282 Solid Urethane foam core Yes 1.6500 ❑ 283 Mat1283 Solid mineral fiberboard core Yes 1.7816 ❑ 284 Mat1284 Polystyrene core (18 ga steel) Yes 2.0071 ❑ 1 285 Mat1285 Polyurethane core (18 ga Yes 2.5983 ❑ steel) 2 286 Mat1286 Polyurethane core (24 ga Yes 2.5983 ❑ steel) 1 2/17/2004 EnergyGauge FlaCom FLCCSB v1.22 9 287 Mat1287 Polyurethane core (24 ga Yes 4.1500 ❑ steel) 2 288 Mat1288 Solid Urethane foam core Yes 4.1500 ❑ 81 Mat181 ASPHALT -ROOFING, Yes 0.1500 ❑ ROLL 244 Mat1244 PLYWOOD, 1/21N No 0.6318 0.0417 0.0660 34.00 0.2900 ❑ 185 Mad185 CLAY TILE, PAVER, 3/8IN No 0.0301 0.0313 1.0410 120.01) 0.2000 ❑ 82 Mat182 ASPHALT -SHINGLE AND Yes 0.4400 ❑ SIDING 11 Mad11 2 in. Insulation No 6.6800 0.1670 0.0250 2.00 0.2000 ❑ 95 Mat195 CONC BLOCK No 0.7107 0.3333 0.4690 101.01) 0.2000 ❑ HVv'-4IN-HOLLOW 248 Mat1248 ROOF GRAVEL OR No 0.0500 0.0417 0.8340 55.00 0.4000 ❑ SLAG 1 /2IN 94 Mat194 BUILT-UP ROOFING, 3/81N No 0.3366 0.0313 0.0930 70.00 0.3500 ❑ Constructs Used Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sEF] [Btu/sf.F] [lb/clj [h.sf.FBtu] 1004 Concrete floor, carpet and rubber pad No No 0.60 9.33 140.00 1.6703 ❑ Layer Material Material Thickness Framing No. IN Factor 1 151 CONC HW, DRD, 140LB, 41N 0.3333 0.00 ❑ 2 178 CARPET W/RUBBER PAD 0.00 ❑ 2/17/2004 EnergyGauge F1aCom FLCCSB v1.22 10 9 Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sLF] [Btu/sf.F] [lb/ct] [h.sf.F/Btu] 1011 5/8" stucco /8"CMU/3/4°ISO No No 0.21 5.73 34.65 4.8368 ❑ BTWN24"oc/.5" Gyp Layer Material Material Thickness Framing No. [ft] Factor 1 268 0.625" stucco 0.0521 0.00 ❑ 2 42 8 in. Lightweight concrete block 0.6670 0.00 ❑ 3 269 .75" ISO BTWN24" oc 0.0625 0.00 ❑ 4 187 GYP OR PLAS BOARD,1/21N 0.0417 0.00 ❑ Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sLF] [Btu/sf.F] [lb/cf] [h.sEF/Btu] 1043 Sngl Ply/2"Iso/Mtl Deck/6'BATT No No 0.04 0.64 4.77 27.1200 ❑ Layer Material Material Thickness Framing No. IN Factor 1 82 ASPHALT -SHINGLE AND SIDING 0.00 ❑ 2 11 2 in. Insulation 0.1670 0.00 ❑ 3 23 6 in. Insulation 0.5000 0.00 ❑ 2/17/2004 EnergyGauge FlaCom FLCCSB v1.22 t1