Loading...
HomeMy WebLinkAbout4639 W 1 St (3)i 4w.. Whole Building Performance Method for Commercial Buildings Form 4.O0A-97 ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs FLA/COM-97 Version 2.2 PROJECT NAME_ECKERD - SANFORD PERMITTING OFFICE: ADDRESS: _SANFORD 39 . / _Sanford - _FLORIDA .3aJ?.: CLIMATE ZONE: _5 OWNER: _ECKERDS PERMIT NO: AGENT: JURISDICTION NO:_691500 BUILDING TYPE: _Mercantile (Retail) CONSTRUCTION CONDITION: New construction DESIGN COMPLETION: _Finished Building CONDITIONED FLOOR AREA: _11200 NUMBER OF ZONES: 1 MAX. TONNAGE OF EQUIPMENT PER SYSTEM: COMPLIANCE CALCULATION: METHOD A DESIGN CRITERIA RESULT A. WHOLE BUILDING 69.15 100.00 PASSES PRESCRIPTIVE REQUIREMENTS: LIGHTING LIGHTING CONTROL REQUIREMENTS PASSES HVAC EQUIPMENT COOLING EQUIPMENT 1. EER 9.90 8.50 PASSES IPLV 9.90 7.50 PASSES HEATING EQUIPMENT 1.. Et 1.00 N/A AIR DISTRIBUTION SYSTEM INSULATION REQUIREMENTS 1. Unconditioned Space 4.20 4.20 PASSES REHEAT SYSTEM TYPES USED NO REHEAT SYSTEM is USED WATER HEATING EQUIPMENT 1. EF 0.90 0.89 PASSES 2. EF 0.92 0.92 PASSES PIPING INSULATION REQUIREMENTS 1. Non -Circulating ---------------------------------------------------------------------------- 1.00 1.00 PASSES COMPLIANCE CERTIFICATION: I hereby' certify ' htft'-the plans and Review of the and specifica- specifications-c&v-e're y this calcu- plans tions covered by this calculation lation_are'in compliance with the indicates compliance with the Florida Enerq'y--Ef dh y Code. Florida Energy Efficiency Code. PREPARED.BY: - Before construction is completed, DATE: this building will be inspected for compliance in accordance with I hereby certify t,hat'this building is Section 553.908, Fliarida ti}te in compliance with the Florida Energy BUILDING OFFIC AL: Efficiency Code. DATE: — —162 k 0 0 r r OWNER/AGENT: DATE: Y I hereby certify(*) that the system design is in compliance with the Florida Energy Efficiency Code. SYSTEM DESIGNER REGISTRATION/STATE ARCHITECT ' MECHANICAL: PLUMBING : A.i.olAP-- f-L ELECTRICAL: LIGHTING (*) Signature is required where Florida law requires design to be performed by registered design professionals. Typed names and registration numbers may be used where all relevant information is contained on signed/sealed plans. BUILDING ENVELOPE SYSTEMS 'COMFLI. C� 401.------GLAZING--ZONE 1 ---------------------------------------------- Elevation Type U SC VLT Shading Area(Sgft) ------------------------ ---- ---- ---------------------------- North Commercial 1.1 .71 .51 Continuous Ove 240 Total Glass Area in Zone 1 = 240 Total Glass Area = 240 402.------WALLS--ZONE 1 ------------------------------------------------ Elevation Type U Insul R Gross(Sgft) ----------------------------------------- ----- ------- ----------- North 811CMU\0.75 POLY\ 0.5 0.13 4 1600 South 811CMU\0.75 POLY\ 0.5 0.13 4 1600 East 8"CMU\0.75 POLY\ 0.5 0.13 4 2800 West 8"CMU\0.75 POLY\ 0.5 0.13 4 2800 Total Wall Area in Zone 1 = 8800 Total Gross Wall Area = 8800 403.------DOORS--ZONE 1 ------------------------------------------------ Elevation Type U Area(Sgft) --------------------------------------------------- ----- ---------- East 1-3/4 Steel Door -Solid Urethane foam co 0.40 21 South .25 STEEL ROLL -UP 0.75 80 South 1-3/4 Steel Door -Solid Urethane foam co 0.40 21 Total Door Area in Zone 1 = 122 Total Door Area = 122 404.------ROOFS--ZONE 1 ------------------------------------------------- Type Color U Insul R Area(Sgft) ------------------------------------ ------ ---------------------- BUR\R-19\AIR SPACE\.5 ATC Medium 0.04 19 11200 Total Roof Area in Zone 1 = 11200 Total Roof Area = 11200 405.------FLOORS-ZONE 1 ------------------------------------------------ Type Insul R Area(Sgft) ---------------------------------------------------------------- Slab on Grade/Uninsulated 0 11200 Total Floor Area in Zone 1 = 11200 Total Floor Area = 11200 406.------INFILTRATION -------------------------------------------------- ICHECK Infiltration Criteria in 406.1.ABCD have been met. MECHANICAL SYSTEMS %NCE iECK --v- CHECK ------------------------------------------------------------ ---- --- HVAC load sizing has been performed. (407.1.ABCD) 407.------COOLING SYSTEMS----------------------------------------------- --- Type No Efficiency IPLV Tons ---------------------------- ------------- ------------------- 1. Air Cooled ( >= 65,000 Btu/h 1 9.9 9.9 36.92 408.------HEATING SYSTEMS----------------------------------------------- --- Type No Efficiency BTU/hr -------------------------------- ---'------------------------ 1. Electric Resistance 1 1 180495 409.------VENTILATION --------------------------------------------------- --- Ventilation Criteria in 409.1.ABCD have been met. I CHECK 410.-----AIR DISTRIBUTION SYSTEM---------------------------------------- --- 5 CHECK -----------------------------------------------------------` - --- Duct sizing and design have been performed. (410.1.ABCD) I AHU Type Duct Location R-value ---------------------------------------------------------------- 1. Packaged Constant Volume Unconditioned Space 4.2 CHECK - --- ---------- ----- --- ----------- ------------- Testing and balancing will be performed. (410.1.ABCD) 411.-----PUMPS AND PIPING -ZONE ----------------------------------------- --- Basic prescriptive requirements in 411.1.ABCD have been met. PLUMBING SYSTEMS 411.-----PUMPS AND PIPING -ZONE 1 --------------------------------------- Type ------------------------ R-value/in Diameter Thickness 1. Non -Circulating ---------- 4.0 -------- 1 --------- 1 412.-----WATER HEATING SYSTEMS -ZONE 1---------------------------------- --- Type ------------------------ Efficiency StandbyLoss -------------------- InputRate ---------- Gallons ---------- 1. <=12 kW .90 0 4.5 30 2. <=12 kW .92 0 1.5 10 ELECTRICAL SYSTEMS CHECK 413.-- --ELECTRICAL POWER DISTRIBUTION ----------=----------------- ----- --- Metering criteria in 413.1.ABCD have been met. 414.-----MOTORS --------------------------------------------------- ----- --- Motor efficiencies in 414.1.ABCD have been met. 415.-----LIGHTING SYSTEMS -ZONE 1--------------------------------------- --- Space Type No Control Type 1 No Control Type 2 No Watts Area(Sgft) Type D(Gen 1 On/Off 15 None 0 21600 11200 Total Watts for Zone 1 = 21600 Total Area for Zone 1 = 11200 Total Watts = 21600 Total Area = 11200 CHECK Lighting criteria in 415.1.ABCD have been met. 16. Operation/maintenance manual will be provided to owner.(102.1) ----------------------------------------------------------------------------