HomeMy WebLinkAbout550 W First Stv SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772 (407 302-2520 / FAX (407) 302-2526 Plans Review Sheet Date: December 14, 2004 Business: 550 West First Street Occ. Ch. 34(Mercantile) Business Name: C. VS. S. Pharmacy Contractor: Richard Davis FPI Architect/Engineer: Larson Design Group Reviewed [ ] Ph. (214) 706-6671 Ph. (800) 607-4CVS Ph. (570)323-6603 Ph. (570) 323-9902 Rejected [ ] Reviewed by: Timothy Robles, Fire Protection Inspector/Plans Examiner % \"�r Comment: Plans reviewed as (Mercantile) Occupancy (8,988 sq. ft) FD reserves right to require applicable code requirements if occupancy use changes. Sprinkler plans to be submitted for review, permitting, and inspections ( design criteria not stated). Fire Alarm plans to be submitted for review, permitting, and inspections. 1.1 Application — New Building. Type V> Fire sprinkler protected 1.2 Mixed — N/A 1.3 Special Definitions — Bulk merchandise retail 1.4 Classification of Occupancy — (Mercantile) 1.5 Classification of Hazard of Contents — (Mercantile) Class "B " 1.6 Minimum Construction — See Sanford build depts. Comments 2.2 Means of Egress Components — The rear exit in the storage area shall have yello,�u stripping on floor 44" showing delineated path of travel. 2.3 Capacity of Egress — Per table 7.3 in (F. F.P. C.) sales floor (1) per 30 sq. ft. Storage one person (])per 300 sq. ft 2.4 Number of Exits —Additional°EXIT,ShGNREOUIRED (See Blue Pans)' Ll SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772 (407 302 2520 / FAX (407) 302 2526 2.5 Arrangement of Egress — Na storagealloed„tn the 44"1N sle extt access( eeblu p nts 2.6 Travel Distance — Exits were placed less than 200' (fy, from any point of travel inside building. 2.7 Discharge from Exits — O.K., will field verify 2.8 Illumination of Means of Egress — O.K.; will field verify; with 2.9 Emergency Lighting — Two more emergency lights required 1 > "main electrical shut off"; 2.10 Marking of Means of Egress — Additional Exit sign may be required 2.11 Special Features — (Reserved) 3.1 Protection of Vertical Openings — Shall comply with sec8.2.5 of FFP.C. 3.2 Protection from Hazards — N/N 3.3 Interior Finish — Class "A" &"B" only allowed inside store 3.4 Detection, Alarm and Communications Systems — ..................... . 3.5 Extinguishing Requirements —as per NFPA 10; four)> 4A rated J 3.6 Corridors — See Sanford building dept. for construction requirment - 4 Special Provisions - 5 Building Services 5.1 Utilities — 5.2 HVAC — as per LSC 9-2 "'( e all duct detectors „auto main fire', Elevators, Escalators, Conveyors (4A-47) — N/A 5.4 Rubbish Chutes, Incinerators, and Laundry Chutes — N/A Sanford City Code — Chapter 9 Fire Sprinklers: Required; Monitoring: Required by a U.L. listed Central Station for all mandated fire sprinklered properties Other: NFPA 1 3-5.1 Fire Lanes — Required by F.D.0 hose connection 3-6.1 Key Boxes — ►A N SANF'ORD FIRE DEPAR"I'MEN"I' FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, H. 32771 / P. O. Box 1788, Sanford, Fl. 32772 (407 302-2520 / FAX (407) 302 2526 _ 3-7.1 Bldg. Address Number Posted and Legible —Required, will fielduerlfy; sf l;lue Prints: CARBON � :� D E S I G N G .R...O.._U...P 1000 Commerce Park Drive, P.O. Box 487 Williamsport, PA 17703-0487 Phone: (570) 323-6603 FAX: (570) 323-9902 ATTENTION: BUILDING CODE OFFICIAL The Construction Documents submitted with this application for permit are extremely limited in the scope of work to be performed. This overview is attached to briefly.summarize the limited nature of work planned and hopefully help expedite the review process. PROJECT OVERVIEW This project consists of refurbishing the Interior Spaces only of the existing building, with no exterior work being proposed as part of this Scope of Work. There is no proposed structural work. The existing means of egress have not been modified or altered in any way. No modifications, additions, or alterations have been proposed to the following existing building systems: Sprinkler, Fire Alarm, Emergency Lighting, Exit Signs, and ADA Accessibility. All electrical work being proposed is with relocated and/or redistributed circuits; no additional services or panels are required. An existing sink is being relocated and r-placed, by extending and re -using the existing water and sanitary services already in pladV Robert J. Gehr, A.I.A., NCARB Architect of Record — State Of Florida Seal #AR0092168 A complete Scope of Work can be found on the Construction Documents attached with this submission. Thank You