SANFORD FIRE DEPARTMENT
FIRE PREVENTION DIVISION
300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772
(407 302-2520 / FAX (407) 302-2526
Plans Review Sheet
Date: December 14, 2004
Business: 550 West First Street Occ. Ch. 34(Mercantile)
Business Name: C. VS. S. Pharmacy
Contractor: Richard Davis FPI
Architect/Engineer: Larson Design Group
Reviewed [ ]
Ph. (214) 706-6671
Ph. (800) 607-4CVS
Ph. (570)323-6603
Ph. (570) 323-9902
Rejected [ ]
Reviewed by: Timothy Robles, Fire Protection Inspector/Plans Examiner %
\"�r
Comment: Plans reviewed as (Mercantile) Occupancy (8,988 sq. ft) FD reserves right to require
applicable code requirements if occupancy use changes. Sprinkler plans to be submitted for
review, permitting, and inspections ( design criteria not stated). Fire Alarm plans to be submitted
for review, permitting, and inspections.
1.1 Application — New Building. Type V> Fire sprinkler protected
1.2 Mixed — N/A
1.3 Special Definitions — Bulk merchandise retail
1.4 Classification of Occupancy — (Mercantile)
1.5 Classification of Hazard of Contents — (Mercantile) Class "B "
1.6 Minimum Construction — See Sanford build depts. Comments
2.2 Means of Egress Components — The rear exit in the storage area shall have yello,�u stripping
on floor 44" showing delineated path of travel.
2.3 Capacity of Egress — Per table 7.3 in (F. F.P. C.) sales floor (1) per 30 sq. ft.
Storage one person (])per 300 sq. ft
2.4 Number of Exits —Additional°EXIT,ShGNREOUIRED (See Blue Pans)'
Ll
SANFORD FIRE DEPARTMENT
FIRE PREVENTION DIVISION
300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772
(407 302 2520 / FAX (407) 302 2526
2.5 Arrangement of Egress — Na storagealloed„tn the 44"1N sle extt access( eeblu p nts
2.6 Travel Distance — Exits were placed less than 200' (fy, from any point of travel inside
building.
2.7 Discharge from Exits — O.K., will field verify
2.8 Illumination of Means of Egress — O.K.; will field verify; with
2.9 Emergency Lighting — Two more emergency lights required 1 > "main electrical shut off";
2.10 Marking of Means of Egress — Additional Exit sign may be required
2.11 Special Features — (Reserved)
3.1 Protection of Vertical Openings — Shall comply with sec8.2.5 of FFP.C.
3.2 Protection from Hazards — N/N
3.3 Interior Finish — Class "A" &"B" only allowed inside store
3.4 Detection, Alarm and Communications Systems —
..................... .
3.5 Extinguishing Requirements —as per NFPA 10; four)> 4A rated J
3.6 Corridors — See Sanford building dept. for construction requirment
- 4 Special Provisions
- 5 Building Services
5.1 Utilities —
5.2 HVAC — as per LSC 9-2 "'( e all duct detectors „auto main fire',
Elevators, Escalators, Conveyors (4A-47) — N/A
5.4 Rubbish Chutes, Incinerators, and Laundry Chutes — N/A
Sanford City Code — Chapter 9
Fire Sprinklers: Required;
Monitoring: Required by a U.L. listed Central Station for all mandated fire
sprinklered properties
Other: NFPA 1
3-5.1 Fire Lanes — Required by F.D.0 hose connection
3-6.1 Key Boxes —
►A
N SANF'ORD FIRE DEPAR"I'MEN"I'
FIRE PREVENTION DIVISION
300 N. Park Ave., Sanford, H. 32771 / P. O. Box 1788, Sanford, Fl. 32772
(407 302-2520 / FAX (407) 302 2526 _
3-7.1 Bldg. Address Number Posted and Legible —Required, will fielduerlfy; sf
l;lue Prints:
CARBON � :�
D E S I G N
G .R...O.._U...P
1000 Commerce Park Drive, P.O. Box 487
Williamsport, PA 17703-0487
Phone: (570) 323-6603 FAX: (570) 323-9902
ATTENTION:
BUILDING CODE OFFICIAL
The Construction Documents submitted with this application for
permit are extremely limited in the scope of work to be performed.
This overview is attached to briefly.summarize the limited nature of
work planned and hopefully help expedite the review process.
PROJECT OVERVIEW
This project consists of refurbishing the Interior Spaces only of the existing building, with no
exterior work being proposed as part of this Scope of Work.
There is no proposed structural work.
The existing means of egress have not been modified or altered in any way.
No modifications, additions, or alterations have been proposed to the following existing building
systems: Sprinkler, Fire Alarm, Emergency Lighting, Exit Signs, and ADA Accessibility.
All electrical work being proposed is with relocated and/or redistributed circuits; no additional
services or panels are required.
An existing sink is being relocated and r-placed, by extending and re -using the existing water and
sanitary services already in pladV
Robert J. Gehr, A.I.A., NCARB
Architect of Record — State Of Florida Seal #AR0092168
A complete Scope of Work can be found on the Construction
Documents attached with this submission.
Thank You