Loading...
HomeMy WebLinkAbout1801 Airline Ave4e?,lopa // �/AR Whole Building Performance Method for Commercial Buildings ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs FLA/COM-94 Version 2.1A PROJECT NAME_K099622957 A-D ADDRESS: _630 EAST LANDSTREET ROAD_ ORLANDO,FLORIDA 32824 _ OWNER: —RESUN LEASING, INC.,__ AGENT: M Form 40OA-94 `�� Date t— 6L-j Pfnn No. Ni �S Approved By ClAYTON E. BARRQWS i Modular Dullding Plana Examiner PERMITTING OFFICE: Florldo Certificate No. 017 _Orlando CLIMATE ZONE: _5 PERMIT NO: _N/A � JURISDICTION NO:_582100 ; BUILDING TYPE: _Business (Office)_ CONSTRUCTION CONDITION: New Construction DESIGN COMPLETION: _Finished Building,_ CONDITIONED FLOOR AREA: _2730 MAX. TONNAGE OF EQUIPMENT PER SYSTEM: .4 NUMBER OF ZONES: 1 COMPLIANCE CALCULATION: METHOD A'• DESIGN CRITERIA RESULT A. WHOLE BUILDING 56.87 100.00 PASSES PRESCRIPTIVE REQUIREMENTS: LIGHTING EXTERIOR LIGHTING 240.00 694.00 PASSES LIGHTING CONTROL REQUIREMENTS PASSES HVAC EQUIPMENT COOLING EQUIPMENT 1. SEER ' 10.00 9.70 PASSES HEATING EQUIPMENT 1. Et 1.00 N/A AIR DXSTRIBUTION SYSTEM INSULATION LEVEL 1, Ventilated 6.00 6.00 PASSES WATER HEATING EQUIPMENT 1, EF 0.93 0.92 PASSES PIPING INSULATION REQUIREMENTS 1. Non -Circulating Wo H 1.00 1.00 PASSES ------------------ ---------------------------------------------------- `` COMPLIANCE CERTIPICATICIZ Y hereby certify' that lthe� 016,ns &.rid Review of the .pllans. and specifica- j specifications _coveLed,by tions covered by this calculation lation are in c:omralian-de with ­the' indicates compliance with the Florida Ener off- i r-. 'Co Florida Energy Efficiency Code. PREPARED Y: Before construction is completed, RATE this building will be inspected 4 for compliance in accordance with I hereby certify that th >:'building is Section 553.908, Florida Statutes. in compliance with.the Florida Energy BUILDING OFFICIAL: Efficiency Code. DATE: OWNER/AGENT: DATE: I hereby certify(*) that the system design is in compliance with the Florida Energy Efficiency C de. REGISTRATXQN STATE �� S TENT n S IG E s �s i MECHANICAL: _ ' PLUMBING 3 _ ELECTRICAL: --- LIGHTING (*) Signatu a is required where Florida law reciuires desiA performed by registered design professionals. Typed names and regis umbers may be used where all relevant information is contained on si ned/sealed plans. s G :.•==va0-W=co=CGW Wc�ccolll ��r ,j BUILDING INFORMATION COMPLIANCE CHECK 401.-------GLAZING--ZONE 1------------------------------------------------ v- Elevation Type U SC VLT Shading Area(Sgft)l ------------------------ ---- ---- ----------------------------j Raet Residential 1.13 .74 .89 None 581 North Residential 1.13 .74 .89 None 581 South Residential 1.13 .74 .89 None 291 Total Glass Area in Zone 1 - 1441 Total Glass Area = 1441 402.------WALLS--ZONE 1---------------------------------------- -------- j--- Elevation Type - r _-_ U Added R Goss(sgft) - --------------------------------------- --------- -------j East Frame Wall + 3" InS. 0.081 4801 West Frame Wall + 3" In$. 0.081 4801 North Frame Wall + 3" InS, 0.081 3741 South Frame Wall + 311 InS. 0.081 3741 Total Wall Area in Zone 1 = 17071 Total Gross Wall Area = 17071 403------- DOORS --ZONE 1,------------------------------------------------ i --- Elevation Type r U A ea(Sgft) --------- ------------------------^------------_---- -------------j East 1.75 STORE FRONT 1.13 421 East 1.75 STORE FRONT 1.13 1051 West 1.75 STORE FRONT 1.13 211 Total Door Area in Zone 1 = 1681 Total Door Area = 1681 404------- ROOFS --ZONE 1------------------------------------------------ i--- Type Color U Added R Area(Sgft)l ------------------------------------ ------ --------------- j TRUSS W/R-19 INSULATION Medium .05 28021 Total Roof Area in Zone 1 28021 Total Roof Area = 28021 405------- FLOORS -ZONE 1---------- --------------------------------------j--- Type R Area(Sgft)j ----------------------------------------------------------------I Floor over Unconditioned Space/Insulated 11 28021 Total F1ocr Area in Zone 1 = 28021 _ Total Floor Area = . 28021 406------- INFILTRATION -------------------------------------------------- I--- ICHECK Infiltration Criteria in 406.1.A13C.1 have been met. 1 j 407------- COOLING SYSTEMS-=----------------------------=-------�---------�- - Type - No Efficiency. IPLV Tonsi ---------------------------- --------.---- --------------- 1. Single Package 4 10 l 3.50j 408.------HEATING SYSTEMS--------------------------------------- ----- --- No Efficiency BTU/hrj ��--------------- ------ ----------------------_----j 1. Electric Resistance _ 1 255751 409------- VENTILATION ---------- ^----------- ^--------- -------------------- i--- JCHECK Ventilation Criteria in 409.1.ABC.I,have been. met. 410.-----AIR DISTRIBUTION SYSTEM---------- -------------------------"-- AHU tYpe Duct Location R-value --------------------------------- ------------------------.---� 1'. Split / PTAC Air Conditioner Ventilated 61 s .. 411.-----PUMPS AND PIPING -ZONE 1---------------------------------------�--- Type R-value/in Diameter Thickness] ---------------------------------------------------� 1. Non -Circulating w/o Heat 4 .75 1� 412------ WATER HEATING SYSTEMS, -ZONE 1----------------------------------�--- Type Efficiency StandbyLoss InputRate Gallons( -------------------------.93---------- ----- --- ---------- I 1. a-12kW 413------ ELECTRICAL POWER DISTRIBUTION----------------------------------I--- ICHECK Metering Criteria in 413.1.ABC.1 have been met. Transformer criteria in 413.1.ABC.2 have been met. 414------ MOTORS --------------------------- ^----------------------------` _ Motor efficiencies in 4,14.1.ABC.1 have been met. I 415------ LIGHTING SYSTEMS -ZONE 1---------------------------------------�-"- Space Type No Control Type 1 No Control Type 2 No Watts Area(Sgft)i --- ------ ----------------- ----------------- --- ------ ----------I Reading, T 1 On/Off 4 425E 20331 Reading, T 1 On/Off 2 456 3131 Toilet and 2 On/Off 2 608 3011 Total Watts for Zone 1 = 53201 Total Area for Zone 1 - 264.81 Total Watts - 53201 j Total Area = 26481 I 1CHECK� Lighting criteria in 415.1.ABC have been met. ---------------------------------------------------------------- (-----�--_ 16. HVAC load sizing has been, performed. (407.1.ABC.1) ---------------------- ------------------------------------------------ 17. Duct sizing and design have been performed. (410.1.ABC.1.2) ----------------------------------------------------------------- f-----(--- 18. Testing and balancing will be performed. (410.1.ABC.4) ---------------------------------------------------------------- -----� -_ 19, Operation/maintenance manual will be provided to owner.(102.1)1 t j4j