Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
621 Grovewood Ave; 17-3125; WINDOWS
OCT 2 4 2017 Ij L CITY OF SANFORD Ely BUILDING & FIRE PREVENTION PERMIT APPLICATION 2 Application No: Documented Construction Valuci S 3 ID-1 Job Address: 0A N_t Historic District: YesEl No 91 Parcel ID:1_1 3b-5bS- USOOUNO Residential 91 Commercial n Type of Work: Newn AdditionEl Alteration 3 Repair n DemoEl Change of UscEl move El Description of Work - REPLACE t7 C_ Plan Review Contact Person: MEGAN CONSTABLE Title: AGENT Phone: 352-300- 3360 Fax: 352-861-7587 Einail, PERMITSPLUSLLC@GMAIL.COM Property Owner Information Phonc:Aol-'tb- ` 444 Streetll GVMNA fat Resident of property? YES City, State Zip"Q I IbIL—M) Name LOWES - PETER A CAFARO Street- PO BOX 781933 City, State Zip: ORLANDO, FL 32878 Contractor Information Phone-, 352- 300-3360 Fax: 861-7587 State License No.: . CGC1508417 Arch i te ct/ Enginee r Information Natne: N/A Phone: Street: City', St, zip: Fax: E-mail: Bonding Company: N/A Mortgage Lender. Address: Addrm: WARNING TO OWNER. YOUR FAILURE TO RECORD A No*rtcF ot: COM M ENCEMENT MAI' RESULT IN YOUR PAYING 11VICE FOR EMPROVENIES" IS TO VOUR PROPERTY, A NOTtcr OF cO1I",NIE,-"CEmFNT MUST BE RECORDED AND POSTED ONTHE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WIT11 I' OUR I.ENDER Olt AN ATTORNEY BEFORE RECORDING YOUR NOTICE, OF COMM FNNCEMENT. Application is hereby made to obtain a pert -nit to do the work -and installations as indicated. I certify that no work or installation has commenced prior to the issuance or a permit and that all work will be performed to meet standards of all livvs regulating construction in this jurisdiction. I understand thnt at separa(c permit most be secured for electrical work, plumbing, signs, Wells, Pont$, furnaces, boilers, heaters, tanks, and air conditioners, etc. FUC 105-3 Shall be inscribed with the tinte of application and the code in effect jjz orlhat date: 511 VdItion (2014) Florida lluilding Code Rcviscl June 30. 2015 PCIM14 Application e NOTICE: In addition to the requirements of this permit. there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law. FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current [CC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. s%nature oroumeriAgau Ck" Prins (MmdAgau's Nwne Sipmre orNowy-suft or Florida Date ka-Ak sign C=uta&/A*& pate Hal!WA14 YOVVIA L Prue Contractor/Agem's game 3--/7 DEBBIE BLAN T ON MY COMMISSION # I F 178648 EXPIRES: February 25, 2019 Bonded Thro Notary Public Undenwiiers Owner/Agent is Personally Known to Me or Contractor/Agent is Personally own to Me or Produced 1D Type of ID Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Ell' Electrical Mechanical Plumbing[] Gas[] Roof Construction Type: Occupancy Use: Flood Zone: Total Sq Ft of Bldg: Min. Occupancy Load: # of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes No # of Heads APPROVALS: ZONING: UTILITIES: ENGINEERING: COMMENTS: FIRE: Fire Alarm Permit: Yes No WASTE WATER: BUILDING: Revised: June 30. 2015 Permit Aposeation R]EQUMEIID HNSPlECTI[ON SEQUENCE iR P# 1 1- 3\ ZS Address: C2l BUILDING (PERMIT mim maxC - Inspection Description Footer / Setback Stemwall Foundation / Form Board Survey Slab / Mono Slab Prepour Lintel / Tie Beam / Fill / Down Cell Sheathing — Walls Sheathing — Roof Roof Dry In Frame Insulation Rough In Firewall Screw Pattern Drywall / Sheetrock Lath Inspection Final Solar Final Firewall Final Roof Final Stucco / Siding Insulation Final Final Utility Building Final Door Final Window Final Screen Room Final Pool Screen Enclosure Final Single Family Residence Final Building (Other) IE'LECT.RICA:L F-E'RM-1T min Max Ins ection Description Electric Underground Footer / Slab Steel Bond Electric Rough T.U.G. Pre -Power Final Electric Finial 3+ut. rt...n•yr x:'. ..-L'"AY?"113 i'l.'_. 7s_n t'•'" Z`c.t+ n p .1 '... > Ilf-li ( ...ri I'J[nn Max lus ection Descrn tn®n Plumbing Underground Plumbing Sewer Plumbing Tub Set Plumbing Final RI, Inspection Ih;scripflom Mechanical Rough Mechanical Final YtlI •r 1`Is....lu 3; .... n•. tj4z0N.} 7 13'. w ul.`P :7+S'{.cZ••r";';tt,'.ut;.. ,(+:i.•:, - U, _:) L• ::• 1i5:"%7•iSr rl ...+3 n7 rY nr°er y.7iY LJ:. A.t,ra i`y't.'iC •"F_,7t1.._ iJ i 1' turn. s.rJ11•:.t6a;L i?t.L'•...:.sltc,.:l.tiii':...li'.n Y•c'_V:i•.:::.,:t _ef s; erlptlon Gas-Underground KC W • M. REVISED: June 2014 JAI&i L 73Cr/To CUSTOMER:- PRICE CALCULATIONS: In ord Rr to properly perform th6 installation of certain G6ods, the Contract Price rr(ay include mor6fGbodsthanactuallywillbeinstalledbasedonthemeasurecsquarefootageoftheProjectArea. As a result, the 'parties agree that the lump -sum Price Tm stated in this Contract is calculated upon both the value -of estimated Goods required to fulfill the Contract (including Ste). which may exceed the actual square footage of the Project Area, and the labor which may By signing this Contract below, Customer acknowledges receipt estimated based — — the amount of Goods'requir2g fill the Contract (including waste). of this notice and agrees and understands that the ' ,pludes these costs which may not be refunded once the Installation Services re ,,.aperformec, NOTICE TO CUSTOMER: Federal law r Ul !SL(044PS(to vide you with the pamphlet Renovate Right. By signing thiqVC, C nowledges 00"; havingthisSContract Total receivedacopyofpamphletfCunInfoffningstomerof the potential risk of the lead hazard exposure from rmen vatlon a cfivfty to be tioapplicable taxes included performed In Customer's dwelling unit. NOTE: ff rotted wood is discovered during installation additional charges will pI You will be given a quote a a change order must be completed and signed by the customer Tor an additional charges. Customer must Initial -7 Any work or material not specified Any 34 .3 iedisnotIncludedinthiscontraAchangesoradditionswill * 5t an additional charge for the material abor. NOTICE TO OWNER: — ACCORDING TO FLO IDA'S CONSTRUCTION, LIEN LAW (SECTIONS 713.001-713.37, FLORIDA- STATUTES), THOSE WHO WORK ON YOUR PJ'PERTY OR PROVIDE MATERIALS AND SERVICES AND ARE NOT PAID IN FULL HAVE A RIGHTTOENFORCE THEIR CLLAAI FOR PAYMENT AGAINST YOUR PROPERTY. THIS CLAIM IS KNOWN AS CONSTRUCAWL . IF YOUR CONTRACTOR OR A SUBCONTRACTOR FAILS TO PAY SUBCONTRACTORS, SUB-SUBOONTRAM0, 11S, OR MATERIAL SUPPLIERS, THOSE PEOPLE WHO ARE OWED MONEY MAY LOOK TO YOUR PROPERTY FOR PAYMENT, EVEN IF YOU HAVI ALREADY PAID YOUR CONTRACTOR IN FULL. IF YOU FAIL TO PAY YOUR CONTRACTOR, YOUR CONTRACTOR MAY ALS, HAVE A LIEN ON YOUR PROPERTY. THIS MEANS IF A LIEN IS FILED YOUR PROPERTY COULD BE SOLD AGAINST YOUR ILL TO PAY FOR LABOR, MATERIALS,. OR OTHER SERVICES THAT YOUR CONTRACTOR OR A SUBCONTRACTOR MAY i AVE FAILED TO PAY. TO PROTECT YOURSELF, YOU SHOULD STIPULATE IN THIS CONTRACT THAT BEFORE ANY PAYME NT IS MADE, YOUR CONTRACTOR IS REQUIRED TO PROVIDE YOU WITHA WRITTEN RELEASE OF LIEN FROM ANY PERS)N OR COMPANY THAT HAS PROVIDED TO YOU A "NOTICE TO OWNER." FLORIDA'S CONSTRUCTION LIEN LAW IS COMPLEX, AND IT IS RECOMMENDED THAT YOU CONSULT AN ATTORNEY. PHOTO RELEASE: Customer grants to Lowe's and Lowe's e nployees and independent contractors the right. to take photographs of the Premises where Installation Services will be performed and all work performed interest in to the for at the Premises related to this Contract, and irrevocably grants to Lowe's all right, title and and photographs use in all markets and.rT edia, worldwide, in perpetuity. Customer authorizes Lowe's to copyright, use and publish the photographs inprint and/or electronically, and agrees that Low)'s may use such photographs for any lawful purpose, including but not limited to, marketing, advertising, publicity, illustration, training and Web content. By initialing he, Customer agrees to the foregoingk= [Customer to initial to the iefil. Work is t commence upon reasonable avallability'of Co tractor and/or any special order or customer de Goo d( -s') I which Is anticipated to be 0'e, [ fill in date]. Estim sakf estimated substantial corm` 16 p tiondateis not M', 3ted completiondateis44-4:kk4Aq, 9a , , . (fill in date]. ice. A statement of any contingencies that would mat nay change said estimated substantial compl,,tion 0 q _*eis as follows: Aep 1C, 4. L ( if applicable, insert a statement of such contingencies). This Contract provides that If Oalms y Cpstomeq6r Lo vje's w!H tw resolved by, 8114DING ARBITR*TION.-'Custome6and Lowe's GIVE UP4,HE RIGHT, rformad. ly signing this Contract neiow. t.us v„•• _....... lot be refunded once the installation Services are pe Prdv IOnCE 7O CUSTOMER: Federal law ontract Crt_ y>s2Rl samphiet Renovate Right. By 9 act, began itlavingreceivedacopyofthispamphletbafoTryrfthepotentialriskoftheleadhazardexposurefromrenovat performed in Customer's dwelling unit. instailatior LATE: if rotted wood is discovered during ai Anyworek completed tapd {signed ind the icustomer m rAn FLORII NOTICE TO OWNER: - AC ARKONYOUR PROF STATUTES, THOSE WHO W FULL HAUC ON H =TN ENFORCEURT CONTRACT1 R CLAIM CONSTRUCTION R MATERIAL SUPPI SUB -SUBCONTRACTORS, OR IF YOU HAVE 1PROPERTYFORPAYMENT, CONTRACTOR,COULD R CONTRACTOR MAY ALSO PROPER SOLD AGAINST YOUR W1 CONTRACTOR THATBEFORE ANY PAYMEIINTHISRELEASEOFLIENFROMANYPEIRSC FLORIENrSCONSTRUCTION LIEN LAW iS COMP! FLORiDA PHOTO RELEASE: Customer grants to Lawe's and Lowes er installation Services will be performedlse anallwork performed markets and m interest in and to the photog p rear that Lowy photographs in print and/or electronically, and agrees advertising; publicity, illustration, training and Web content. By n reasonable availability of CO Workistocommencet [fife in date]. Estir Said estimated substantial co,pletion date is not of ijhe esst completion . oeiss as follows, Gustarneror Lov This Contract provides ththis Contract (Eat allclaimsbyTO GO TO COURT to enforce T orceARBITRATOR andCNOT arit determined by proceALduresareSIMPLERANDMORE LIMITED THAN RUL FOFare subject to VERY LIMITED REVIEW BY A COURT. N TRIALANDWAIVEROFCLASSACTIONADJUDICATIONDO NOT SIGN THIS CONTRACT UNTIL COMPLETE PAGESOFTHISCONTRACT. BY SIGNING BELOM ANDAGREETOSHETERMSANDCONDITIONSSCOPYOFTHISCONTRACTATTHETIMEOFSIGtWITNESS OUR HAND(S) AND SFJ1i-(S) BELOW THIS _- Lowe' 1-(I/ime;Qpnter; LC I . f • l j. 1 '.. rr p t orized I' a resentative` i_ + Customer acknowledges re~eipt of a true copy of this a cancel thistransactionatanytimepriortomidnightof1formfor an explanation of this right. 55106 REV. 12J13 1 t you with the T` Itnowiedges Contract Total ,f `\—, ' rming Customer es included , { ! activity to be*applicable tax e order dditionaf charges will ppt. You will be given a quote a d a Chang Customer mustinitialadditionalcharges: It or additions wits fan additional charge for the material and`labor RIDN IS CONSTRUCTION. LIEN LAW ND S€RICES AND ARE NNS OT PAID iNRTYORPROVIDE MATERIALS A IRPAYMENT AGAINST YOUR PRA LS QTPAY SUBCONTRACTORS, CLAIM OR A SUBCONTRACTOR F TO RS, THOSE PEOPLE WHO ARE R NED MON Y0KFAILTO A©IU1RREADYEN ON CONTRALTO SERVICES THAT YOUR WE A LIEN ONYOURPROPERTHORMEANSTNRFALIENiSFILEDYOURTOPAYFORLABOR, MATERIALS,YOU E FAILED TO PAY. TO PROTECT IS REQUIRED TO SHOULDYOU WITH A IS MADE, YOUR CONTRACTOR OR COMPANY THAT HAS PROVIDEDTYOU CONSULT ANT ATTORNEY. X,,AND I7IS RECOMMENDED ra hs of the Premises where yees and independent contractors the right to take Yhogrants to Lawe's allright, title and the Premises relatedothis Contract, ontrertauthorizesirrevLaowe's tocopyright• use and publish the a, worldwide, in perpetuity,{awful purpose, including, but not limited to, marketing, i 9• may use suchphotographsfor any (Customer to initial to the leftJ. tinlino here, Customer agrees to the foregoing.: _. ed to be for andlor any special order or customer ' completion date is . 't contingencies that would A statement of any contingencies), if appticable, insert a statementofsuchswillberesatvedby BINDING ARB .RA +CCIURT)• Lowe's and Customer's rights will be m atters thatay be taken toSMALLLA fge or Jury court order and Lowe's and Customer areentitledtoaFAIRHEARING. But the,arbitratwn WAIVER OF JURY S APPLICABLEIN, COURT. AlldecisionsareasenforceableasaMOREDETAILS: Review the section titled ARBITRATION AGREEMENT, Dund in the Terms andConditionsofthisContract. I iN ALL AND YOU HAVE READ THE TERM 0 EREAD, UNDERSTA,N YOU ARE ACKNOWLEDGING THATYOU FORTH ON ALLPAGESOFTHISCONTRACT. YOU ARE ENTITLED TO A kTURE, < DAY OF , ll Good(s)'which Is anttc,pat fill in date]. i y change` said estimated substantial Y .. f)ner Gaowner or Witness s execution hereof. You, the buyer, r ract which was eomptowy filled in priortoCustomer' notice of cancetlatit third business day after the date of this transaction. See the attached 0 2004 trY Y.ow® s. t, own's and ti+s gable desi5n ate+. FILE COPY are r0goered trademark Ppof LF GW THIS 1 T P PARED BY: Name: US Address: _ O _j L MA tot M NOTICE OF COMMENCEMENT Permit Number:_--_-_ n---2—^-.,.----------_-^n—.---- Parcel ID Number: L'.7y' 45• ft'V 'L(0 ri ( r ri{...i} . SEr1:r 1x.E COUNTY LE:'M 0i--:' r.1:>1:CUIT COURT & CONF'TROLIER CLERK'S tt 2017107611 RE;;ORDECr BY hdevorr:= T he undersigned hereby gives notice that improvement will be made to certain real property. and in accordance with Chapter 713. Florida Ine toilowing information is provided in this Notice of Cominencernent. 2. G NERAL DESCRIPTION OF IMPROVEMENT: JZeo(JM W j r&W 5 ap Cbo! S - 3. OWNER INFORMRIO,,N,,OR LESSEE INFORMATION IF THE LESSEE CONTRACTED FOR THE IMPROVEMENT Narne and addressV Ifl%x-dbi (N_—_l.e_2.1 C2!v_Zw4od__P.__G{ c __...32'1 3..._... __. _ _ . Interest in property:OW n,e Fee Simple Title Holder (if other than owner listed above) Name:_N Address: _ rr r _ 4. CONTRACTOR: Narne:``LO ekeC QJJTt-Yb Phone Number Address :—w7" q 1l(v -320— _. -. _.._... . _ _ _ __. _._ ... _ __ 5. SURETY (if applicable, a copy of the payment bond is attached): Narne U Address: _ _ _ Amount of Bond: 6. LENDER: Narne_N I Ia _ — Phone Number. Address: 7. Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes. Narne Phone Number. Address:_ 8. In addition.. Owner designates ._.._... _._ ____ _. of to receive a copy of the Lienors Notice as provided in Section 713.13(1)(b), Florida Statutes. Phone number. 9. Expiration Date of Notice of Commencement (The expiration is 1 year from date of recording unless a different date is specifiedi WARNING TO OWNER. ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEIMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713. PART I, SECTION 713.13. FLORIDA STATUTES. AND CAN RESUt_T IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SHE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Jlq dl..l rl. a1 v.ner nr Lessee _ or Uwners or Lesscy, i5U11 on-%t;i OII;--ei L), Ix P;k,l=icr r.-1 nna-,m) State of _ .- for + i' Count ofnp..__ ti rant Nllrrx t-.,• ptrr: 7 a.,.r ;il=fir rh-i V' e; The foregoing instrument was acknowledged before me this f "', day of 0C-t .20 17 by b1p: r rJ;vnC• cd ;.9G rsOC rr=in;t 51 [st e+Went who has produced identification 'X type of identification produced: PAUL HOLMES MY COMMISSION #FF965167 EXPIRES: FEB 28. 2020 Bonded through 1st State Insurance IMPROVING HOME IMPROVEMENT P. O. Box 781993 Orlando, Florida 32878 Phone: (407) 393-9161 Facsimile: (407) 407-393-9151 Limited Power of Attorney Date: AoWn To: Building Dept. From: Peter Anthony Cafaro III I hereby name and appoint, Megan Constable, Gregory Galas, Donna Biggers, Joshua Galas, Christy Galas, or Hailigh Schwingel, a permit service for Lowes Home Centers, to be my lawful attorney in fact to act for me to register my license and apply to: C for a n dW permit for work to be performed at: Lot: ^Blk: Sec: Twp: Rage: a Subdivision `UY W Parcel or Altkey: `D' L6' -;6'9'5' o 000- V zo Address of Job: W, ci fw wood , t Owner of Property: and to sign and dq t YKhings necessary to this appointment. Thank you foxytlur assistance. 7P ter Anthony Cafaro III rimary State Qualifier CGC 1508417 State of Florida County of Orange The foregoing instrument was acknowledged before me by Peter Anthony Cafaro III, who is personally known to me and who did not take an oath. Sworn to ands scribed before me this W day of 00DW 2017. Notary Public ( & A oL, My Commission Expires: 10/21/2018 1PRY Pia" ANNES.ROMANO [SEAL] MY COMMISSION # FF 166860 EXPIRES: October 21, 2018 v Bonged Thru Budget Notary servicesTy., OF F10 Product Approval Specification Form SUQo,\ Permit # * 17 - 3 1 2'! Project Location Address As required by Florida Statute 553.842 and Florida Administrative Code 9N-3, please provide the information and product approval number(s) on the building components listed below if they are to be utilized on the construction project for which you are applying for a building permit. We recommend that you contact your local product supplier should you not know the product approval number for any of the applicable listed products. Be aware that windows, skylights, and exterior doors must be tested in accordance with the Florida Building Code, Section 1714.5. More information about Statewide Product Approval can be obtained at www.floridabuilding.org. The following information must be available on the jobsite for inspections: 1. This entire product approval form 2. A copy of the manufacturer's installation details and requirements for each product. Category / Subcategory Manufacturer Product Description Florida Approval # include decimal) 1. Exterior Doors Swinging Sliding REVIEWED FOR CID Sectional Roll U PLANS EXAMINER Automatic Other Ic 2. Windows Single Hun p Horizontal Slider Casement Double Hun Fixed Awning-- TO RE A Pass Through A PERMIT E e&4ST-RUED To 12RC)rpEn WITH THE WO K AND NOT ASHGENSEProjectedAUTHORITYTOVIOLATE, CANCEL, Mullions ASIDr ISSUANCE OF A P RMIT PREVENT Wind Breaker THE BUILDING OFFICIAL FR M Dual Action CoNSTAI IrTION OR VIOLATIONS C F THIS CODE Other June 2014 Category / Subcategory Manufacturer Product Description Florida Approval # including decimal) 3. Panel Walls Siding Soffits Storefronts Curtain Walls Wall Louver Glass block Membrane Greenhouse E.P.S Composite Panels Other 4. Roofing Products Asphalt Shingles Underla ments Roofing Fasteners Nonstructural Metal Roofing Wood Shakes and Shingles Roofing tiles Roofing Insulation Waterproofing Built up roofing System Modified Bitumen Single -Ply Roof Systems Roofing slate Cements/ Adhesives / Coating Liquid Applied Roofing Systems Roof Tile adhesive Spray Applied Polyurethane Roofing E.P.S. Roof Panels Roof Vents Other June 2014 Category / Subcategory Manufacturer Product Description Florida Approval # include decimal 5. Shutters Accordion Bahama Colonial Roll up Equipment Other 6. Skylights Skylights Other 7. Structural Components Wood Connectors / Anchors Truss Plates Engineered Lumber Railing Coolers/Freezers Concrete Admixtures Precast Lintels Insulation Forms Plastics Deck / Roof Wall Prefab Sheds Other 8. New Exterior Envelope Products Applicant's Signature Applicant's Name MEGAN CONSTABLE Please Print) June 2014 P 14, F2 bF ILITC-q'N UT(4T x c CND 5,2 Kc Nl ' it hiA.1 Fl . C r- A (U-46 -S Go 100-3 //V (ab4AI L , CVof Florida Building Code Online Page 1 of 1 BCIS Home ', Log In ; User Registration ' Hot Topics I Submit Surcharge Stats & Facts i Publications FBC Staff ; BCIS Site Map I Links Search bProduct Approval i.USER: Public Userr Product Approval Menu > Product or Application Search > Application List Search Criteria Refine Search Code Version 2014 FL# 16812.1 Application Type ALL Product Manufacturer ALL Category ALL Subcategory ALL Application Status ALL Compliance Method ALL Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL Product Model, Number or Name ALL Product Description ALL Approved for use in HVHZ ALL Approved for use outside HVHZ ALL Impact Resistant ALL Design Pressure ALL Other ALL FL# Type Manufacturer Validated By Status FL16812-R2 Revision Pella Corporation FL#: FL16812.1 Terrence E. Lunn, PE 561) 625-6455 Approved History Model: 250 Series Single Hung Window Description: 36" x 63" vinyl non -impact single window Category: Windows Subcategory: Single Hung Approved by UBPR. Approvals by UBPR shall be reviewed and ratlned by the PUC and/or the Commission it necessary. Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1624 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: n zi http://www.floridabuilding.org/pr/pr_app_lst.aspx 10/20/2017 1. ALL FASTENERS SHALL BE IN ACCORDANCE WITH THESE DRAWINGS. SPECIFIED ANCHOR EMBED TO BASE MATERIAL SHALL BE BEYOND WALL FINISH OR STUCCO. 2 OPENINGS, BUCKING &BUCKING FASTENERS MUST BE PROPERLY DESIGNED &INSTALLED TO TRANSFER FOR MAX. FRAME WIDTH, SEE NOTE BELOW Al FOR MAX. FRAME WIDTH, SEE NOTE BELOW Plnr: I.I. are3 05"` WIND LOADS TO THE STRUCTURE. 3,THESE NON -IMPACT RATED WINDOW SYSTEM INSTALLATIONS ARE IN ACCORDANCE WITH AND MEET THE 4 a REQUIREMENTS OF THE FLORIDA BUILDING CODE (FBC). 4. ALL ANCHORS SECURING WINDOW FRAME TO PRESSURE TREATED BUCKS OR WOOD FRAMING SHALL BE 4" MAX. CAPABLE OF RESISTING CORROSION CAUSED BY THE PRESSURE TREATING CHEMICALS IN THE WOOD. MATERIALS, INCLUDING BUT NOT LIMITED TO STEEL SCREWS, THAT COME INTO CONTACT WITH OTHERRDISSIMILARMATERIALSSHALLMEETTHEREQUIREMENTSOFFLORIDABUILDINGCODECHAPTER20. 6. TO THE BEST OF OUR KNOWLEDGE, THE WINDOWS SHOWN HEREIN ARE CERTIFIED & QUALITY ASSURED FIN FASTENER WITHIN 2" BY A FLORIDA STATE APPROVED CERTIFICATION/QA ENTITY & SHALL BE LABELED IN ACCORDANCE WITH THE CORNERS & 4 12ING FRAME SCREWS WHERE SHOWN FBC AND THE 9N-3 FLORIDA BUILDINGOFCOMMISSIONSPECIFICATIONS. WINDOW ASSEMBLY IS NOT PART OF MAX. O.C. WHEN JOB AT SIDES. SEE "FRAME ANCHOR THIS DRAWING AND SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S QUALITY ASSURANCE SPECIFICATIONS & TESTING REPORTS. REQUIRED DESIGN REQUIREMENTS TABLE" ON THIS o 7. CERTIFICATION OF THESE WINDOW INSTALLATIONS SHALL BE CONSIDERED VOID IF ANY OF THE PRESSURE IS OVER +/-35 3 SHEET FOR REQUIREMENTS. FOLLOWING APPLY: 1) THEY ARE INSTALLED WITHOUT A BUILDING PERMIT FROM THE APPLICABLE LOCAL BUILDING DEPARTMENT. 2) IF THEY ARE INSTALLED BY ANYONE OTHER THAN A LICENSED CONTRACTOR Cl 5 9 C2PSF; 9" MAX. O.C. WHEN wm 5 NOTE THAT WHEN JOB REQUIRED DESIGN PRESSURE ISEXPERIENCEDWITHWINDOWINSTALLATIONS. 3) IF CHANGES HAVE OCCURRED TO THE PRODUCT'S CERTIFICATION ENTITY'S CERTIFICATE THAT CAUSE THESE INSTALLATIONS TO BE INCORRECT OR INCONSISTENT JOB REQUIRED DESIGN PRESSURE IS +/-35 PSF w OVER +/-35 A FRAME FILLER WITH WHAT HAS BEEN TESTED. B. THE LEAST DESIGN PRESSURE SPECIFIED EITHER IN THIS DRAWING OR IN THE PRODUCTS CERTIFICATION pORLESS. SEE "FRAME z MUST BE USED AT EACH FRAME SCREW, SEE SHEEP 5 FOR SHALL CONTROL FOR THE INSTALLED WINDOW. 9. THESE DRAWINGS CERTIFY THE WINDOW INSTALLATION ONLY. WATER PROOFING OF THE INSTALLED ANCHOR REQUIREMENTS wTABLE" ON THIS SHEET PART DETAIL) WINDOWS IS NOT PART OF THIS INSTALLATION CERTIFICATION. THAT RESPONSIBILITY SHALL BE THAT OF THE OR INSTALLER. FOR REQUIREMENTS. j 2" MANUFACTURER 6' 30,oo 3CHo;sue INSTALLATION EVALUATION IS BASED ON APPLICABLE ANDR STANDARDS AND/OR INFORMATION & RESULTS FROM APPLICABLE TEST REPORTS. THE FLORIDA BUILDING CODE VERSION CONSIDERED WITH THE CLUSTER FlN FASTENERS AT a U g N 5 v EVALUATION WAS THAT IN FORCE AT THE TIME OF THE EVALUATION. IN THE EVENT OF CODE VERSION CHANGES/UPDATES OR IN THE EVENT THAT NEW OR ADDRIONAL TESTING IS COMPLETED ON THE MEEFING RAIL ENDS SUCH THAT ZE Qa a REFERENCED PRODUCT, PRIOR TO STATING CODE COMPLWNCE WITH THE STATE, THE MANUFACTURER SHALL THERE ARE A.TOTAL OF 5 0 CONFIRM WITH THE INSTALLATION EVAUTATION ENGINEER OF RECORD THAT THE INSTALLATIONS SPECIFIED HERE -IN ARE CURRENT WITH THE THEN CURRENT TESTING, CODE AND APPUCABLE STANDARDS. POSITIONED AS SHOWN. SEE "- FRAME FRAME ANCHOR REQUIREMENTS TABLE ANCHOR REQUIREMENTS TABLE" ON THIS SHEEP FOR z .p IL OPENING TYPE FRAME/CLIP/NAIL FIN TO MINIMUM MINIMUM REQUIREMENTS. B1 CDZ LJ- SUBSTRATE) OPENING FASTENER TYPE EMBED EDGE DIST. 1) FRAME SCREWS 4" MAX. COo K0 MIN. 2X4 WOOD FRAME OR BUCK GR. 3 & G=0.55) NO. 10 SMS OR WOOD SCREW 1 1/4" 3/4" - MINM.E c0Z to GA 33 KSI METAL STUD NO. 10 GR. 5 SELF TAP DRILL SCREW FULL 1/2" m 1/8" THK A36 STEEL NO. 10 GR. 5 SELF TAP DRILL. SCREW FULL 1/z" EXTERIOR ELEVATION: EXTERIOR ELEVATION: s a 8" THK 5063-T5 ALUM. NO. 10 GR. 5 SELF TAP DRILL SCREW FULL 1/2" SINGLE WINDOW SINGLE WINDOW 6a CMU OR 25DO PSI CONCRETE (2) 1/4" CONCRETE SCREW 1 1/4" 2" SCALE: 3/4" = 1'-O" SCALE: 3/4" = 1'-O" I INSTALLATION CLIP SCREWS NAIL FIN MOUNT CONDITION) FRAME SCREW MOUNT CONDITION) v, 4 WOOD FRAME OR BUCKN0. 10 SMS SCREW 1 1/4 GR. 3 & G=O.55) 1/2IN. JAMB Main O. U GA. 33 KSI METAL STUD NO. 10 GR. 5 SELF TAP/DRILL SCREW FULL 1/z NOTE: FOR MAX. SINGLE SIDE 1/8" THK A36 STEEL NO. 10 GR. 5 SELF TAP DRILL SCREW FULL 1/2" WINDOW FRAME DIMENSIONS ANCHOR SPACING TABLE'"°'"""sN3EAHKR. 5 SELF PS DRIeLLW SCREWLUM. N0.( 2101 4" 1 2" AND ALLOWABLE DESIGN OOTPSI CONCRETETS CONCRETE 1F1 4" MAXIMUM MAXIMUM `P•S33N,3PRESSURE, SEE APPLICABLE 3) NAILING FIN FASTENERS FLORIDA APPROVAL W WIDTH SPACING COO JIN. 4 WOOD FRAME OR BUCK NO. 8 SMS SCREW 1 3/8" 1/2" O : IN.) (IN.) Z d, La GR. 3 & G=0.55) 54 12 U 0. MIN. 2X4 WOOD FRAME OR BUCK MIN. GR. 3 & G=0.55) 11 GA. ROOFING NAIL 1 3/8" 1/2" F 48 13 •' 2 . Z 36 17 . J6, •' 8" THK A36 STEEL NO. 8 GR. 5 SELF TAP/DRILL SCREW FULL 1/2" NOTE: Q` THK 6063-TS ALUM. N0. B GR. 5 SELF TAP/DRILL SCREW FULL 1/2" ALTERNATE ANCHOR/SUBSTRATE EVALUATION ALL ALTERNATE ANCHORS IN THEIR SPECIFIED6••*pDINSTALLATIONCLIPSCREWSSHALLBEAPANORHEXHEADSCREW. SUBSTRATES HAVE BEEN ANALYZED IN ACCORDANCE WpIN R . 1'V67SCREWSSHALLBEELCOULTRACONS (C.S.), ELCO CRETE-FLEX (S.S.), ITW WITH THEIR APPLICABLE STANDARD($) AND ARE FOUND 1HESE DRAWINGS ARE APPLICABLE ONLY TO THE PRODUCT TO BE EQUIVALENT TO OR STRONGER THAN THE SPECIFIED. THEY MAY NOT BE USED FOR THE ASSEMBLYnEDHEADTAPCONS (C.S. OR S.S.) OR HILTI KWIK-CON II (C.S OR S.S.). AHD/OB IN oN of ANY PRODUCT NOR MAYTHEYSHEETN0. ND/OTHERBEUSEDFORMTONAIAND/OR LOCAL APPROVALREWSAREUSEDWITHTHENAILFIN, THEY MUST BE A PAN HEAD OR WAFFLE HEAD ANCHOR(S) USED IN TESTING WITH THIS PRODUCT. =OA R HAVE A FLAT WASHER AT THE SCREW HEAD. OF ANY PROD NOT PNGoucEO in THE MANUFACTURER STATED ON THESE DRAWINGS. of rJ DRAWNWAYB!: LHFLI(m Wf: M.MS 48" MAX. FRAME WIDTH PLDT: 611E Al 4 FOR MAX OVERALL FRAME WIDTH SEE SIDE -BY -SIDE WINDOW CLUSTER FIN FASTENER SCREWS AT MULLION ENDS SUCH THAT THERE ARE A 2" TOTAL OF 3 POSITIONED AS o SHOWN. SEE "FRAME ANCHOR REQUIREMENTS TABLE" ON SHEET 1 FOR SCREW REQUIREMENTS. Y NOTE THAT ROOFING NAILS w ARE NOT APPLICABLE AT MULLION END CLUSTERS) w w CLUSTER FIN FASTENERS 2 Cl AT MEETING RAIL ENDS Z F waSUCHTHATTHEREAREA 3 N o x TOTAL OF 5 POSITIONED AS 2 o o o mo,> o SHOWN. SEE "FRAME z a o z 5ANCHORREQUIREMENTS3 5TABLE" ON SHEET 1 FOR REQUIREMENTS. a I FIN FASTENER WITHIN 2" Z ClLo OF CORNERS & z p 9" MAX. O.C. SEE "FRAME o ANCHOR REQUIREMENTS Z TABLE" ON SHEET 1 FOR REQUIREMENTS. c z Ul zomK EXTERIOR ELEVATION: z aN SIDE —BY —SIDE WINDOW EXTERIOR ELEVATION: S v, x w . SCALE: 3/4" = 1'-O" NAIL FIN MOUNT CONDITION) SINGLE WINDOW WITH TRANSOM w a wd 80 , SCALE:, 3/4" = 1'-O" rn z R^ Y "g; NAIL FIN MOUNT CONDITION) o N Nco $ a ALLOWABLE DESIGN PRESSURE gib TRANSOM UNITS ONLY) 35 PSF tJy i ny.: oN J / co rn :z d ,.r C);Zwd ¢ 3:w3w i- co) 0. E\ 1867 SHEET N0. 2 of 5 30 SIZE/PRESSURE TABLE ON THIS SHEEP 2" 2 Al 4 j Q CLUSTER FIN FASTENER SCREWS AT MULLION ENDS SUCH THAT THERE ARE A TOTAL OF 3 c=i1 POSITIONED AS SHOWN. SEE "FRAME ANCHOR REQUIREMENTS TABLE" ON SHEET 1 FOR C1 SCREW REQUIREMENTS. (NOTE THAT ROOFING NAILS ARE NOT APPLICABLE AT MULLION END in N I CLUSTERS) o m FIN FASTENER WITHIN 2" OF CORNERS & CLUSTER FASTENERS AT 4 1/2" MAX. O.C. WHEN JOB REQUIRED DESIGN MEETING RAIL ENDS SUCH THAT PRESSURE IS OVER +/-35 PSF; 9" MAX. O.C. THERE ARE A TOTAL OF 5 m w WHEN JOB REQUIRED DESIGN PRESSURE IS +/-35 POSITIONED AS SHOWN. SEE FRAME ANCHOR REQUIREMENTS PSF OR LESS. SEE "FRAME ANCHOR REQUIREMENTS TABLE" ON SHEET 1 FOR TABLE" ON SHEET 1 FOR REQUIREMENTS. REQUIREMENTS. B1 ALLOWABLE SIDE —BY —SIDE WINDOW SIZE/PRESSURE TABLE MAXIMUM MAXIMUM ALLOWABLE OVERALL FRAME PRESSURE FRAME HEIGHT PSF) WIDTH DIMENSION DIMENSION IN.) IN.) TRIPLE WINDOW 109 63 35 DOUBLE WINDOW 96 72 35 72 65 1 2 50 j Q j j j j t 81 FOR MAX. OVERALL FRAME WIDTH, SEE SIDE -BY -SIDE WINDOW SIZE/PRESSURE TABLE ON THIS SHEET INDIVIDUAL WINDOW WIDTH INDIVIDUAL WINDOW WIDTH INDIVIDUAL WINDOW WIDTH 4" MAX. 13 1/4" TLTL 3" 13 1/4" 1 FI TI, 3 13 1/4" 4" MAX. MAX. O.C. MAX. O.C. 1 11 MAX. O.C. A2 4 _ 1 wWww C2 iww 5 v U U3wU3 wax z Z jw3o1 0 r 0 0N I FRAME SCREWS WHERE SHOWN AT HEAD & a SIDES. SEE "FRAME ANCHOR REQUIREMENTS TABLE" ON SHEET 1 FOR REQUIREMENTS. (NOTE THAT WHEN JOB REQUIRED DESIGN PRESSURE IS OVER +/-35 A FRAME FILLER MUST BE USED AT EACH FRAME SCREW, SEE SHEET 5 FOR PART DETAIL) I I I INSTALLATION CLIPS WHERE SHOWN AT SILL. SEE "FRAME ANCHOR REQUIREMENTS TABLE" ON SHEET 1 FOR REQUIREMEiT. 11 4 4" MAX. --I MAX.104C. 4 A 1/ 4. 4 1 4„ 4„ MAX. O..CC . EXTERIOR ELEVATION: SIDE -BY -SIDE WINDOW SCALE: 3/4" = 1'-O" FRAME SCREW AND CLIP MOUNT CONDITION) ALLOWABLE SIDE -BY -SIDE WINDOW SIZE/PRESSURE TABLE MAXIMUM MAXIMUM ALLOWABLE OVERALL FRAME PRESSURE FRAME HEIGHT PSF) WIDTH DIMENSION DIMENSION IN.) IN.) TRIPLE WINDOW 109 1 63 35 DOUBLE WINDOW 96 72 35 72 65 1 2 1 50 12 1/4 MAX. O.C. 4" MAX. 4" MAX. 4" MAX. SIDE JAMB ANCHOR SPACING TABLE MAXIMUM MAXIMUM INDIVIDUAL O.C. WINDOW SPACING WIDTH (IN.) IN.) 48 13 36 17 48" MAX. FRAME WIDTH 4" MAX. — j 3" j 3" 3. 3" FRAME SCREWS WHERE SHOWN AT SIDES. SEE "FRAME ANCHOR REQUIREMENTS TABLE" ON SHEET 1 FOR REQUIREMENTS. C2 5 v 6" j O I o 4" MAX. EXTERIOR ELEVATION: SINGLE WINDOW WITH TRANSOM SCALE: 3/4" = 1'-0" FRAME SCREW MOUNT CONDITION) ALLOWABLE DESIGN PRESSURE TRANSOM UNITS ONLY) 35 PSF 05z00W w ' Za L o z UU Vfz 30 6 3 'a OF FIN FASTENER ELEVATION SEALANT BY OTHERS-\ BEHIND NAIL FIN SEALANT BY OTHERS F—IF FRAME SCREW PER ELEVATION SUBSTRATE BY SUBSTRATE BY SUBSTRATE BY OTHERS PER FRAME SCREW OTHERS PER SEALANT BY OTHERS OTHERS PER FRAME ANCHOR PER ELEVATION FRAME ANCHOR BEHIND FRAME FLANGE FRAME ANCHOR REQUIREMENTS x :`•: ,,; REQUIREMENTS t ,- : REQUIREMENTS TABLE" TABLE" TABLE" 1/4" MAX. 1/4" MAX. SHIM 1/4" MAX. SHIMVATSPACEATEACHANCHOREACHANCHOR SEALANT BY SEAL-ANTBY OTHERS THRST 1 1OTHERS1 SEAL SPACE WITH LOW EXPANSION EXTERIOR lti FOAM AROUND PERIMETER OF WINDOW FRAME SECTION Al SCALE: 3/4 FULL 4 NAIL FIN MOUNT) EXTERIOR SEAL SPACE WITH LOW EXPANSION FOAM AROUND PERIMETER OF WINDOW FRAME---, EXTESEAL SPACE WITH 4" LOW EXPANSION FOAM AROUND FRAME FILLER PERIMETER OF WINDOW FRAME SECTION A2 SCALE: 3/4 FULL 4 FRAME SCREW MOUNT CONDITION) E 2 1 U EXTERIOR SEAL SPACE WITH w w LOW EXPANSION = 4 FOAM AROUND w FRAME FILLER PERIMETER OF < WINDOW FRAME EXTERIOR I SEAL SPACE WITH LOW EXPANSION w SHIM R TO FOAM AROUND R AL SUPPORT & ALIGN PERIMETER OF WINDOW FRAME WINDOW3 NSTALLATION ALTERNATE SECTION A2 SCALE: 1/2 FULL 4 FRAME SCREW MOUNT CONDITION WITH FLANGE) SEALANT BY w SEALANT BY O p p CLIP OTHERS OTHERS 1/ 4:: MAX. SPACE 1/4" MAX. SHIM AS REQ'D TO MAX. SHIM SPACE SUPPORT & ALIGN THICK X 3" WINDOW LONG SHIM t AT EACH CLIP SEALANT BY OTHERS SUBSTRATE BY SUBSTRATE BY OTHERS INSTALLATION CLIP SCREW PER BEHIND NAIL FIN OTHERS PER PER "FRAME ANCHOR FRAME ANCHOR REQUIREMENTS FIN FASTENER PER FRAME ANCHOR REQUIREMENTS TABLE" TABLE" (2 PER CLIP). ELEVATION REQUIREMENTS TABLE" SECTION g2 SECTION gt SCALE: 3/4 FULL 4 SCALE: 3/4 FULL 4 INSTALLATION CLIP MOUNT CONDITION) NAIL FIN MOUNT) z 0UNw' d' O[ O a U y • o -.3 uii tZ` 4 a 4 OF 5 1/4" MAX. SPACE SUBSTRATE BY OTHERS PER FRAME ANCHOR REQUIREMENTS TABLE" FIN FASTENER PER ELEVATION FRAME WIDTH SEAL SPACE WITH LOW EXPANSION FOAM AROUND PERIMETER OF WINDOW FRAME SEALANT BYE: ' .... ouuuOTHERS BEHIND NAIL FIN SEALANT BY OTHERS EXTERIOR SECTION Cl SCALE: 3/4 FULL 5 NAIL FIN MOUNT) CONTINUOUS WOOD MEMBER LESS IN THICKNESS THAN A 2X_ BUCK TO BE MIN. 3 1/2" DEEP (NOT REQUIRED WHEN SHIM SPACE IS WITHIN ALLOWABLE DIMENSIONS SHOWN IN SECTIONS). SEALANT BYE C OTHERS JJjj 1/4" MAX. SHIM AT EACH ANCHOR SUBSTRATE BY OTHERS PER FRAME ANCHOR REQUIREMENTS TABLE" FRAME SCREW • \ PER ELEVATION ' SUBSTRATE BY OTHERS PER "FRAME ANCHOR REQUIREMENTS TABLE" EXTERIOR FRAME SCREW PER 4 ELEVATION & "FRAME FRAME FILLER ANCHOR REQUIREMENTS LVL TABLE" OPTIONAL DIRECT MOUNT DETAIL TO SUBSTRATE WITH SPACER HEAD SECTION SHOWN; SIDES ARE INSTALLED THE SAME) DIRECT MOUNT CONDITION IS NOT APPLICABLE AT SILL) FOR DETAIL NOT SHOWN, SEE OTHER SECTIONS) FRAME HEIGHT — SEAL SPACE WITH LOW EXPANSION FOAM AROUND PERIMETER OF WINDOW FRAME SEALANT BY OTHERS EXTERIOR SECTION C2 SCALE: 3/4 FULL 5 FRAME SCREW MOUNT CONDITION) 0.60.4 -{ T 0.604 --{ 0.860 IUL ' l 2.485 0 I1 l TI 0.059 J 0.059 O FRAME FLANGE O FRAME FLANGE RIGID PVC) RIGID PVC) 1/4" MAX. SHIM AT EACH ANCHOR SUBSTRATE BY OTHERS PER FRAME ANCHOR REQUIREMENTS TABLE" FRAME SCREW--'. PER ELEVATION '-` FRAME HEIGHT ---- SEAL SPACE WITH LOW EXPANSION FOAM AROUND a PERIMETER OFWINDOWFRAME SEALANT BYE o -LJ J OTHERS BEHIND FRAME FLANGE '. SEALANT BY 2 1 OTHERS EXTERIOR ALTERNATE SECTION C2 SCALE: 1/2 FULL 5 FRAME SCREW MOUNT CONDITION WITH FLANGE) 0.375 0.500 i 1.020 0.225 J LENGTH = 3.000" 3.000 FRAME FILLER RIGID PVC) NOTE THAT WHEN 0.500 JOB REQUIRED DESIGN PRESSURE IS OVER +/-35 A FRAME FILLER MUST 41325 r 0.060 BE USED AT EACH FRAME SCREW) 0.293 J ' O3INSTALLATION CLIP RIGID PVC) wozoo Y wa nNJ z UD 3v OF 5