HomeMy WebLinkAbout1751 WP Ball Blvd 05-909 com int remodely" SANFORD FIKE DEPARTMENT O FIRE PREVENTION DIVISION POt 300.N. Park Ave., Sanford, FI. 32771 / P. O. Box 1788, Sanford, Fl. 32772 1 (407 302-2520 IFAX (407) 302-2526 Plans Review Sheet ►-)Sl Date: October 5, 2004 Business Address: t:5-� W.P Ball Blvd. Occ. Ch. 36, Mercantile Class `B' Business Name: Linens & Things Architect: D.L. Moon Ph. (770) 643-6560 FAX ( ?) not on application P H (817) 738-8095 xx 219 Fax. (817) 738-9524 Contractor: T.B.A. (out to bid at time of submittal) with co'li,ntelt p€'�se reply to comments Ph. ( ) Reviewed by: Timothy Robles, Fire Protection Inspector/Plans Examiner Comment: Plans reviewed as Mercantile Occupancy. FD reserves right to require applicable code requirements if occupancy use changes. Sprinkler plans to be submitted for review, permitting, and inspections. Sealed letter from Engineer of Record stating design criteria for sprinkler system needs to be submitted with construction plans. Separate permit required for Fire Alarm. 1.1 Fine Alarm required for monitoring of sprinkler system 1.2Application — New Building (28,418 s. q. ft.) 1.3 Mixed — N/A, over 50 occupancy load 1.4Special Definitions — Class "B" Mercantile Store (Under 30,000 sq ft.) 1.50assification of Occupancy — Mercantile Store Class "B" 1.6 Classification of Hazard of Contents — Ordinary in office areas, and storage area classified as "High Hazard" per L.S.C. 10,11 1.7 Minimum Construction — Shall comply with Florida Building Code 2001 mercantile occupancy Type IV, UNPROTECTED I.. -- .... -- _... SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Part: Ave., Sanford, FI. 32771 / 13. O. Box 1788, Sanford, FI. 32772 (407 302-2520 / FAX (407) 302 2526 1.8 2.2 Means of Egress Components — Reai.stora-e exits .EXIT.SHALL BExDILIN°EATS WITH, 44 '...yellt on floor':leading to EXIT door: ow pain 2.3 Capacity of Egress — sales floor area based on one (])_person per 30 sq ft., storage area based on one (1) person per 300 sq. ft. 2.4 Number of Exits — (Minimal of Two (2) required EXITS) Four Provided 2.5 Arrangement of Egress: Travel distance increased up to 200' (ft) do to fire sprinkler system 2.6 Travel Distance — Reai EXIT SH.ALI BE'DII,INEATED oor leadng;to EXIT door: 2.7 Discharge from Exits — O.K., will field verify 2.8 Illumination of Means of Egress —additional EXIT SIGNS may be required (power shut down test required at night only) 2.9 Emergency Lighting — (1) foot candle (10 1 x & a minimum at any point of 0.1 foot-candle (1LX) measured along the path of egress at floor level. Therefore additional emergency lights may be required, (power shut down test required at night 171 only) Emergency Lighting required inside Main Electrical room and all rest rooms (*). 2.10 Marking of Means of Egress — O.K.; will field verify? 2.11 Special Features —Reserved 3.1 Protection of Vertical Openings — Class (B) mercantile shall have an automatic, are sprinkler system, design criteria SHALL SHOW storage maximum height stora eg area M. 3.2 Protection from Hazards — (See exception 36-3.2.1 .LSC 101) 3.3 Interior Finish — Not required, building has an automatic fire sprinkler system 3.4 Detection, Alarm and Communications System: (as per N.F.PA.72- 3-8.3.1.2 (99) Ed. • 3.5 Extinguishing Requirements — as her NFPA 10, Ejkht (8) fire extinguishers required per N.FP.A... #10 See blue prints (lllinimal 4A 60 B.C. Rated) (*). 5.1 Utilities — as per LSC 7-1 SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, FI. 32771 / P. O. Box 1788, Sanford, Fl. 32772 (407 302-2520 / FAX (407) 302-2526 5.2 HVAC — as per LSC 7-2 5.3 Elevators, Escalators, Conveyors (4A-47) — N/A Sanford City Code — Chapter9: Required; Fire Sprinklers. Tire Department will field verify sight glass at all inspectors test. Monitoring: Required for fare sprinkler system and all inside and outside fire sprinkler valves. Other: NFPA 1 3-5.1 Fire Lanes — Required if building is more than 150' from street; exception: building has fire sprinkler system. 3-6.1 Key Box— One (1) required see application attached 3-7.1 Bldg. Address Number Posted and Legible — Post address in 6" six inch numbers contrasting in color (see blue prints). ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs EnergyGauge F1aCom v1.22 FORM 40OB-2001 Selected Component Compliance for Commercial Buildings Jurisdiction: SANFORD, SEMINOLE COUNTY, FL (691500) Short Desc: 040531 Project: Linens N Things - Sanford Owner: Address: 200 Towne Center Circle Seminole Towne Center City: Sanford State: Florida PermitNo: 0 Zip: 32771 Storeys: 1 Type: Retail (mercantile) GrossArea: 27761 Class: Renovation to existing building Net Area: 27761 Max Tonnage: 16 (if different, write in) Compliance Summary Component WHOLE OR ENVELOPE Compliance Other Envelope Requirements LIGHTING POWER LIGHTING CONTROLS EXTERNAL LIGHTING HVAC SYSTEM PLANT WATER HEATING SYSTEMS PIPING SYSTEMS Met all required compliance from Check List? Design Criteria Result 39,455.00 80,503.77 Not Requested Not Requested PASSES PASSES Not Requested PASSES Not Requested PASSES PASSES Yes/No/NA IMPORTANT NOTE: An input report Print -Out from EnergyGauge FlaCom of this design building must be submitted along with this Compliance Report. 9/16/2004 EnergyGauge FlaCom ,FL"CCSB v1.22 1 COMPLIANCE CERTIFICATION: I hereby certify that the plans and specifications covered by this calculation are in compliance wi Efficiency Code. PREPARED BY: DATE: I hereby certify that this building is in compliance with the Florida Energy Efficiency Code. OWNER AGENT: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed, this building will be inspected for compliance in accordance with Section 553.908, F.S. BUILDING OFFICIAL: PIA S HAULED DATE: CITY OF SANF RD If required by Florida law, I hereby certify (*) that the system design is in REGISTRATION compliance with the Florida Energy Code. No. ARCHITECT: ELECTRICAL SYSTEM DESIGNER: LIGHTING SYSTEM DESIGNER: MECHANICAL SYSTEM DESIGNER: PLUMBING SYSTEM DESIGNER: Gregory R. Schnackel PE 0048442 / FL Gregory R. Schnackel PE 0048442 / FL Gregory R. Schnackel PE 0048442 / FL Gregory R. Schnackel PE 0048442 / FL (*) Signature is required where Florida Law requires design to be performed by registered design professionals. Typed names and registration numbers may be used where all relevant information is contained on signed/sealed plans. 9/ 16/2004 EnergyGaugeF7aCam FLCCSB 0.22 2 Project: 040531 Title: Linens N Things - Sanford Type: Retail (mercantile) Location: SANFORD, SEMINOLE COUNTY, FL (691500) (WEA File: Orlando.TMY) Lighting Power Compliance Space Ashrae Description Area Height No. of AF Design Effective Allowance ID (sq.ft) (ft) Spaces (W) (W) (W) 001 2 Corridor 349 14.0 1 1.00 580 435 279 002 100 Retail Establishments 23,362 14.0 1 1.00 44960 33720 77,095 (Merchandising & Circulation Area) Applicable to all lighting, including accen 003 2 Corridor 108 10.0 1 1.00 180 180 86 009/010 45 Storage & Warehouse - 2,379 14.0 1 1.00 2370 2370 714 Bulky Active Storage Oil 4 Electrical Mechanical 120 14.0 1 1.00 110 110 84 Equipment Room - General 013 4 Electrical Mechanical 59 14.0 1 1.09 60 60 45 Equipment Room - General 004 4 Electrical Mechanical 30 10.0 1 1.14 60 60 24 Equipment Room - General 005 13 Toilet and Washroom 135 8.0 1 1.00 270 270 108 006 13 Toilet and Washroom 135 8.0 1 1.00 270 270 108 007 7 Food Service - Leisure 265 10.0 1 1.00 540 540 663 Dining 014 2 Corridor 151 8.0 1 1.00 180 180 121 012 28 Offices (Partitions>4.5 ft 125 9.0 1 1.00 360 360 262 below ceiling) Enclosed offices, all open plan offices without partitions 016/017 2 Corridor 148 14.0 1 1.00 120 120 118 008 28 Offices (Partitions>4.5 ft 290 9.0 1 1.00 540 540 609 below ceiling) Enclosed offices, all open plan offices without partitions 018 2 Corridor 28 9.0 1 1.12 60 60 25 015 28 Offices (Partitions>4.5 ft 77 10.0 1 1.00 180 180 162 below ceiling) Enclosed offices, all open plan offices without partitions Design 50840 (W) PASSES Effective: 39455 (V) Allowance: 80503.77 (V) 9/16/2004 EnergyGauge F1aCom FLCCSB v1.22 Project: 040531 Title: Linens N Things - Sanford Type: Retail (mercantile) Location: SANFORD, SEMINOLE COUNTY, FL (691500) (WEA File: Orlando.TMY) Fighting Controls Compliance Acronym Ashrae Description Area No. of Design Min Compli- ID (sq.ft) Tasks CP CP ance 001 2 Corridor 349 0 10 1 PASSES 002 100 Retail Establishments 23,362 0 115 30 PASSES (Merchandising & Circulation Area) Applicable to all lighting, including accen 003 2 Corridor 108 0 1 1 PASSES 009/010 45 Storage & Warehouse - Bulky 2,379 0 2 2 PASSES Active Storage Oil 4 Electrical Mechanical Equipment 120 0 1 1 PASSES Room - General 013 4 Electrical Mechanical Equipment 59 0 1 1 PASSES Room - General 004 4 Electrical Mechanical Equipment 30 0 1 1 PASSES Room - General 005 13 Toilet and Washroom 135 0 1 1 PASSES 006 13 Toilet and Washroom 135 0 1 1 PASSES 007 7 Food Service - Leisure Dining 265 0 1 1 PASSES 014 2 Corridor 151 0 1 1 PASSES 012 28 Offices (Partitions>4.5 ft below 125 0 1 1 PASSES ceiling) Enclosed offices, all open plan offices without partitions 016/017 2 Corridor 148 0 1 1 PASSES 008 28 Offices (Partitions>4.5 ft below 290 0 1 1 PASSES ceiling) Enclosed offices, all open plan offices without partitions 018 2 Corridor 28 0 1 1 PASSES 015 28 Offices (Partitions>4.5 ft below 77 0 1 1 PASSES ceiling) Enclosed offices, all open plan offices without partitions PASSES 9/16/2004 EnergyGauge FlaCom FLCCSB v1.22 Project: 040531 Title: Linens N Things - Sanford Type: Retail (mercantile) Location: SANFORD, SEMINOLE COUNTY, FL (691500) (WEA File: Orlando.TMY) System Report Compliance RTU-1 RTU-1 Thru RTU-6 Constant Volume Packaged No. of Units Thru RTi1-6 System 6 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled 135000 to 11.80 8.50 13.30 7.50 PASSES 760000 Btu/h Cooling Capacity Air Handling Air Handler (Supply) - 0.37 0.80 PASSES System -Supply Constant Volume 7 RTU-7 Component Category Cooling System Air Cooled < 65000 Btu/h Cooling Capacity Air Handling Air Handler (Supply) - System -Supply Constant Volume Constant Volume Air Cooled No. of Units Single Package System < 1 Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance 12.00 9.70 8.00 PASSES 0.56 0.80 PASSES PASSES Project: 040531 Title: Linens N Things - Sanford Type: Retail (mercantile) Location: SANFORD, SEMINOLE COUNTY, FL (691500) (WEA File: Orlando.TMY) Water Heater Compliance Description Type Category Design Min Design Max Comp Eff Eff Loss Loss liance Water Heater Storage Water Heater - <=120 [gal] & <= 0.99 0.91 PASSES Electric 12 [kW] PASSES 9/16/2004 EnergyGauge F1aCom FLCCSB v1.22 5 Project: 040531 Title: Linens N Things - Sanford Type: Retail (mercantile) Location: SANFORD, SEM Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance [inches] Runout? Temp [Btu-in/hr Thick [in] Thick [in] [F] .SF.FJ Domestic and Service Hot Water 0.50 False 105.00 0.28 1.50 1.38 PASSES Systems PASSES 9/16/2004 EnergyGauge FlaCom FLCCSB v1.22 ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs EnergyGauge FlaCom v1.22 INPUT DATA REPORT Project Name: 040531 Project Title: Linens N Things - Sanford Address: Seminole Towne Center 200 Towne Center Circle State: Florida Zip: 32771 Owner: Project Information Orientation: North Building Type: Retail (mercantile) Building Classification: Renovation to existing building No.of Storeys: 1 GrossArea: 27761 Zones No Acronym Description- Type Load Profile Area Multiplier Total Area [sq [sq 1 RTU-1 Thru RTU-1 Thru RTU-6 CONDITIONED Uses Building Load 26377.4 1 26377.4 ❑ RTU-6 Profile 2 RTU-7 RTU-7 CONDITIONED Uses Building Load 1384.1 1 1384.1 ❑ Profile 9/16/2004 EnergyGauge F1aCom FLCCSB v1.22 1 Spaces No Acronym Description Type Depth Width Height Multi Total Area Total Volume IN IN [ft] plier [sf] [cf] In Zone: RTU-1 Thru RTU-6 1 001 Vestibule Corridor 26.89 12.98 14.00 1 349.0 4886.5 Q 2 002 Sales Retail Establishments 143.67 162.61 14.00 1 23362.2 327070.5 ❑ (Merchandising & Circulation Area) Applicable to all lighting, including accen 3 003 Corridor Corridor 6.76 15.97 10.00 1 108.0 1079.6 ❑ 4 009/010 Stock/Receiving Storage & Warehouse - 20.87 114.00 14.00 1 2379.2 33308.5 ❑ Bulky Active Storage 5 011 Electrical Room Electrical Mechanical 8.51 14.10 14.00 1 120.0 1679.9 ❑ Equipment Room - General 6 013 Sprinkler Room Electrical Mechanical 6.56 9.00 14.00 1 59.0 826.6 ❑ Equipment Room - General In Zone: RTU-7 1 004 Janitors Closet Electrical Mechanical 3.70 8.10 10.00 1 30.0 299.7 El Equipment Room - General 2 005 Women's Toilet Toilet and Washroom 10.66 12.67 8.00 1 135.1 1080.5 El 3 006 Men's Toilet Toilet and Washroom 7.64 17.67 8.00 1 135.0 1080.0 ❑ 4 007 Break Room Food Service - Leisure 13.24 20.02 10.00 1 265.1 2650.6 ❑ Dining 5 014 Passage Corridor 15.98 9.45 8.00 1 151.0 1208.1 ❑ 6 012 G.M. Office Offices (Partitions>4.5 ft 9.95 12.56 9.00 1 125.0 1124.7 ❑ below ceiling) Enclosed offices, all open plan offices without partitions 7 016/017 Stairs/Vestibule Corridor 9.34 15.85 14.00 1 148.0 2072.5 8 008 Office Offices (Partitions>4.5 ft 15.13 19.17 9.00 1 290.0 2610.4 below ceiling) Enclosed offices, all open plan offices without partitions 9/16/2004 EnergyGauge FlaCom FLCCSB v1.22 2 9 018 Closet Corridor 4.47 6.26 9.00 1 28.0 251.8 10 015 Counting Room Offices (Partitions>4.5 ft 7.76 9.92 10.00 1 77.0 769.8 below ceiling) Enclosed offices, all open plan offices without partitions Lighting No Type Power Control Type No.of [W] Ctrl pts In Zone: RTU-1 Thru RTU-6 In Space: 001 1 Metal Halide 580.00 Programmable timer with 2 ❑ Daylighting 4 step In Space: 002 1 Metal Halide 2900.00 Programmable timer with 2 Daylighting 4 step 2 Suspended Fluorescent 42060.00 Programmable timer with 21 ❑ Daylighting 4 step In Space: 003 1 Recessed Fluorescent - No vent 180.00 Manual On/Off 1 In Space: 009/010 1 Suspended Fluorescent 1870.00 Manual On/Off 1 2 Incandescent 500.00 Manual On/Off 1 In Space: 011 1 Suspended Fluorescent 110.00 Manual On/Off 1 El In Space: 013 1 Suspended Fluorescent 60.00 Manual On/Off 1 ❑ In Zone: RTU-7 In Space: 004 1 Suspended Fluorescent 60.00 Manual On/Off 1 El In Space: 005 1 Recessed Fluorescent - No vent 270.00 Manual On/Off 1 El In Space: 006 1 Recessed Fluorescent - No vent 270.00 Manual On/Off 1 ❑ 9/16/2004 EnergyGauge F1aCom FLCCSB v1.22 3 In Space: 007 1 Recessed Fluorescent - No vent 540.00 Manual On/Off 1 ❑ In Space: 014 1 Recessed Fluorescent - No vent 180.00 Manual On/Off 1 ❑ In Space: 012 1 Recessed Fluorescent - No vent 360.00 Manual On/Off 1 ❑ In Space: 016/017 1 Suspended Fluorescent 120.00 Manual On/Off 1 In Space: 008 1 Recessed Fluorescent - No vent 540.00 Manual On/Off 1 ❑ In Space: 018 1 Recessed Fluorescent - No vent 60.00 Manual On/Off 1 In Space: 015 1 Recessed Fluorescent - No vent 180.00 Manual On/Off 1 ❑ Wails No Description Type Width H (Effec) Multi Area DirectionConductance Heat Dens. R-Value IN [ft] plier [sfJ [Btu/hr. sf. F] Capacity [lb/cf] [h.sf.FBtu] [Btu/sf.F] In Zone: Windows No Description Type Shaded UCen SC Vis.Tr W H (Effec) Multi Total Area [Btu/hr sf F] IN [ft] plier [Sf] In Zone: In Wall: 9/16/2004 EnergyGauge F1aCom FLCCSB v1.22 4 Doors No Description Type Shaded? Width H (Effec) Multi [ft] IN plier Area [sf] Cond. Dens. Heat Cap. [Btu/hr. sf. F] [lb/cf] [Btu/sf. F] R-Value [h.sf.F/Btu] In Zone: In Wall: Roofs No Description Type Width H (Effec) Multi [ft] IN plier Area [sf] Tilt [deg] Cond. Heat Cap [Btu/hr. Sf. F] [Btu/sf. F] Dens. [lb/cf[ R-Value [h.sf.FBtu] In Zone: Skylights No Description Type UCen Shading Vis.Trans [Btu/hr sf F] Coeff W IN H (Effec) Multiplier IN Area [Sf] Total Area [Sf] In Zone: In Roof: Floors No Description Type Width H (Effec) Multi [ft] IN plier Area [sf] Cond. Heat Cap. Dens. [Btu/hr. sf. F] [Btu/sf. F] [lb/cf] R-Value [h.sf.FBtu] In Zone: 9/16/2004 EnergyGauge F1aCom FLCCSB v1.22 5 Systems RTU-1 Thru RTU-6 RTU-1 Thru RTU-6 Constant Volume Packaged System No. Of Units 6 Component Category Capacity Efficiency IPLV 1 Cooling System (Air Cooled 135000 to 760000 Btu/h Cooling Capacity) 2 Air Handling System -Supply (Air Handler (Supply) - Constant Volume) 188100.00 11.80 13.30 6000.00 0.37 RTU-7 RTU-7 Constant Volume Air Cooled Single No. Of Units 1 Package System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System (Air Cooled < 65000 Btu/h Cooling Capacity) 2 Air Handling System -Supply (Air Handler (Supply) - Constant Volume) 63900.00 12.00 8.00 2000.00 0.56 Plant Equipment Category Size Inst.No Eff. IPLV Water Heaters W-Heater Description Capacit Cap.Unit UP Rt. Efficienc Loss 1 Storage Water Heater - Electric 19 Gal 5 [kW] 0.9900 [EF] [%/hr] Ext-Lighting Description Categories. Area/Len/No. of units Wattage 11 [sf/ft/No] [W] 9/16/2004 EnergyGauge F1aCom FLCCSB v1.22 6 Piping No Type Operating Temperature [F] Insulation Conductivity [ Btu-in/h.sf.F] Nomonal pipe Diameter [in] Insulation Is Runout? Thickness [in] 1 Domestic and Service Hot Water Systems 105.00 0.28 0.50 1.50 No ❑ Fenestration Used Name Glass Type No. of Glass SC VLT Frame Frame Panes Conductance Conductance Absorptance [Btu/h.sf.F] [Btu/h.sf.F] Materials Used Mat No Acronym Description Only R-Value RValue Thickness Conductivity Density SpecificHeat Used [h.sf.FBtu] [ft] [Btu/h.ft.F] [lb/cf] [Btu/lb.F] Constructs Used 9/16/2004 EnergyGauge FlaCom FLCCSB v1.22 7 i W. No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.F/Btu] Layer Material Material Thickness Framing No. [ft] Factor 9/16/2004 EnergyGauge F1aCom FLCCSB v1.22 EI 8 J