Loading...
HomeMy WebLinkAbout1220 W 16 St 06-1073 New SFH (2)PERMIT ADDRESS a a CONTRACTOR ADDRESS 'A NUMBERsimPHONE ,•. SUBDIVISION PERMIT # O to - \ 0-13 DATE - a k - 0 0 PERMIT DESCRIPTION Cam' 2- PERMIT VALUATION C7,:A st c) SQUARE FOOTAGE tip q TWA PROPERTY OWNERS ADDRESS 3 ka a c,- I , Z L a -) 3Z,: A J PHONE NUMBER Oi - W A' S r G ELECTRICAL CONTRACTOR MECHANICAL CONTRACTO PLUMBING CONTRACTOR n MISCELLANEOUS CONTRACTOR O PERMIT NUMBER FEE to MISCELLANEOUS CONTRACTOR PERMIT NUMBER FEE CITY OF SANFORD P.O. BOX 1788 SANFORD FL 327721788 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . 6/27/07 Parcel Number . . . . . Property Address . . . Subdivision Name . . . Legal Description . . . Property Zoning . . . . 35.19.30.503-0000-0370 1220 W 16TH ST SANFORD FL 32771 LOT 37 FLA LAND + COLONIZATION COS ADD TO SOUTH SANFORD PB 1 PG 73 SINGLE FAMILY Owner . . . . . . . . . Smith Bernette O Contractor . . . . . . JIM WALTER HOMES INC 407 295-0981 Application number 06-00001073 000 000 Description of Work NEW SINGLE FAMILY HOME - DETACHED Construction type . . . CONCRETE BLK WITH FRM EXT Occupancy type . . . . SINGLE FAMILY Flood Zone . . . . . . NONE Approved . . . . . . . Qiyl CL,.. /04— Building Official VOID UNLESS SIGNED BY BUILDING OFFICIAL In accordance with this Certificate of Occupancy, all inspections for compliance with Florida Building Code 2004 for occupancy and use have been performed and approved. If the construction project was permitted and built under the owner/builder contractor exemption of Florida State statute 489.103; refer to state statute regarding limitations on renting, lease or sale of this property. BP006UO2 CITY OF SANFORD 6/27/07 Edit Narrative 12:29:08 Application number, type . . . Property address . . . . . . . Type information, press Enter. 06 00001073 NEW SINGLE FAMILY HOME - DE 1220 W 16TH co sign off• P&Z: MR 06.08.07 PW: ok per MW 06.08.07 util: PM 04.16.07 Need final Us ( gave f/s package 6/8/07 More... F3=Exit F5=Copy F6=Insert F7=Delete F8=Time stamp F12=Cancel F21=User defaults U.S. DEPARTMENT OF HOMELAND SECURITY ELEVATION CERTIFICATE OMB No. 1660-0008 Federal Emergency Management Agency Expires February 28, 2009 National Flood Insurance Program Important: Read the Instructions on pages SECTION A - PROPERTY INFORMATION For Insurance Company Use Al. Building Owner's Name 8q-T?` (crrc sin / r Policy Number A2 Building Street Address (including Apt.. Unit. Suite, and/or Bldg. No.) or P.O. Route and Box No. Company NAIC Number CityS i3't d=0 --- State F e— ZIP Code 3 77/ A3. Property Descnphon (Lot and Block Numbers, Tax Parcel Number, Legal Description. etc.) Pr+ fZ C EZ -3t- 3 S I9 3E7 Sa 3 000 0 3 70 nA4. Building Use (e g., Residential, Non -Residential, Addition, Accessory, etc.) 1 `C5(AJT 14 L S1-136 L&F A5. Latitude/Longitude: Lat. .21&—Q 7- / 7 Long. — — S Horizontal Datum: NAD 1927 K NAD 1983A6. Attach at least 2 photograph of the building if the Certificate is being used to obtain flood insurance. AT Building Diagram Number_K A8. For a building with a crawl space or enclosure(s), provide: A9. For a building with an attached garage, provide. a) Square footage of crawl space or enclosures s) l_J — q It a) Square footage of attached garage sq ft b) No. of permanent flood openings in the crawl space or b) No. of permanent flood openings in the attached garage enclosure( s) walls within 1 0 foot above adjacent grade walls within 1.0 foot above adjacent grade c) Total net area of flood openings in A8.bQ sq in c) Total net area of flood openings in A9.b sq in SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION 81. NFIP Community Name & Community Number B2. County Name B3. State 6 c- .Si Fo ! a c 4 S t I dJ oe. E s- 4. Map/Panel Number B5. Suffix 86. FIRM Index B7. FIRM Panel B8. Flood ___T89. Base Flood Elevation(s) (Zone I f 7eS ate Effective/Revised Date Zone(s) AO, use base flood depth) i 9 S N B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item 89. FIS Profile FIRM Community Determined Other (Describe) 611. Indicate elevation datum used for BFE in Item B9: NGVD 1929 NAVD 1988 Other (Describe) B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? Yes No DesignationDate CBRS OPA SECTION C - BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) Cl. Building elevations are based on: Construction Drawings- ' • Building Under Construction' Finished Construction A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations — Zones Al-A30, AE, AH, A (with BFE), VE, V1-V30, V (with BFE), AR, AR/A, AR/AE, AR/A1-A30, AR/AH, AR/AO. Complete Items C2.a-g belowaccordingtothebuildingdiagramspecifiedinItemATBenchmark Utilized :5CM - - C0 _ = ,2 <-R 4 f2 n 1 U Conversion/ Comments Vertical Datum (l D —Z the measurement used. rChecka) Top of bottom floor (including basement, crawl space, or enclosure floor) Z feet meters (Puerto Rico only) b) Top of the next higher floor feet meters (Puerto Rico only) C) Bottom of the lowest horizontal structural member (V Zones only) d) Attached W _ feet meters (Puerto Rico only) garage ( top of slab) e) Lowest Al ._ feet meters (Puerto Rico only) elevation of machinery or equipment servicing the building Describe type of equipment in Comments) feet meters (Puerto Rico only) Lowest adjacent (finished) grade (LAG)l2® feet meters (Puerto Rico only) g) Highest adjacent (finished) grade (HAG) Z® feet meters (Puerto Rico only) SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information. I certify that the information on this Certificate represents my best efforts to interpret the data available. 1understandthatanyfalsestatementmaybepunishablebyfineorimprisonmentunder18U.S. Code, Section 1001. Check here if comments are provided on back of form. FEMA Form 81-31"February 2006 See reverse side for continuation. Replaces all previous editions t Y 1111i` IMPORTANT: In these spaces, copy the corresponding information from Section A. For Insurance Company Use: iuilding Street Address (including Apt., Unit, Sui , and/or Bldg. No.) or P.O. Route and Box No. Policy Number701a-, i- .ter— i i City StateSTQ p ZIP Code Company NAIC Number 277J SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION (CONTINUED) Copy both sides of this Elevation Certificate for (1) community official, (2) insurance agent/company, and (3) building owner. Date Check here if attachments SECTION E - BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO"AND ZONE A (WITHOUT BFE) nor Zones AO and A (without BFE), complete Items E1-E5. If the Certificate is intended to support a LOMA or LOMR-F request, complete Sections A, B. and C For Items E1-E4, use natural grade, if available. Check the measurement used. In Puerto Rico only, enter meters. E1. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacentgrade (HAG) and the lowest adjacent grade (LAG). a) Top of bottom floor (including basement, crawl space, or enclosure s feet meters above or ) i below the HAG. b) Top of bottom floor (including basement, crawl space, or enclosure) is _ feet meters above or below the LAG. E2. For Building Diagrams 6-8 with permanent flood openings provided in Section A Items 8 and/or 9 (see page 8 of Instructions), the next higher floorelevationC2.b in the diagrams) of the building is . _ feet meters above or below the HAG. E3. Attached garage (top of slab) is __ feet meters above or below the HAG. E4 Top of platform of machinery and/or equipment servicing the building is _ feet meters above or E]-.below the HAG. tE5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's floodplain managementordinance? Yes No Unknown. The local official must certify this information in Section G. SECTION F - PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION The property owner or owner's authorized representative who completes Sections A; B, and E for Zone A (without a FEMA-issued or community -issued BFE) or Zone AO must sign here. The statements in Sections A, 8, and E are correct to the best ofmy knowledge Property Owners or Owners Authorized Representatives Name i- -riZ ) r. fS f y LE a] A--yL w 1 64" 9 City State ZIP Code Comments S Date/ // 3 /O 7 Check here if attachments SECTION G -COMMUNITY INFORMATION (OPTIONAL) The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A, B, C (or E), and G of this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement used in Items G8. and G9. G1. The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or architect who G2• is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.) A community official completed Section E for a building located, in Zone A (without a FEMA-issued or community -issued BFE) or Zone AO. G3. The followin 9 i G5. Date Permit Issued G6. Date Certificate Of Compliance/Occupancy Issued G7. This permit has been issued for: New Construction Substantial Improvement G8. Elevation of as -built lowest floor (including basement) of the building: feet El meters (PR) DatumG9. BFE or (in Zone" sAO) depth of flooding at the buildingite: E] feet El meters (PR) Datum Local Official's Name Title Community Name Telephone Signature Date Comments Check here if attachments FEMA Form 81 31, February 2006 Replaces all previous editions Building Photographs See Instructions for Item A6. For Insurance Company Use: Policy Number City _ State ZIP Code Company NAICNumber 9 F-70 Yz D L 7 If using the Elevation Certificate to obtain NFIP flood insurance, affix at least two building photographs below according to the instructions for Item A6. Identify all photographs with: date taken; "Front View" and "Rear View"; and, if required, "Right Side View" and "Left Side View." If submitting more photographs than will fit on this page, use the Continuation Page, following. alp • . 3' i# ,-: '^y1 - {ly 5y%Z` ym.. - mot t,— 71 CITY OF SANFORD PERNtfI' APPLIC ATION rmit H b Address: ascription of Work: istoric District: Zoning: Date: J — Z !6 —tg Total Square Footage Value of Work: S t A V xmit Type: Building Electrical Mechanical Plumbing Fire Sprinkler/Alarm foul ectrical: New Service — H of AMPS Additiol Alteration Change of Service Temporary Pole echanical: Residential Non -Residential Replacement New (Duct Layout & Energy Calc. Required) umbing/ New Commercial: H of Fixtures t / H of Water & Sewer Lines H of Gas Lines umbing/New Residential: H of Water Closets Plumbing Repair — Residential or Commercial eupancy Type: Residential Commercial Industrial instruction Type: H of Stories: -) H of Dwelling Units: Flood ")one: (FFAIA form required ) veers Name & Address mlractor Name & Address: one & Far<: riding Compaay: dress: rrtgage Lcndcr- dress: chitcct/Enginccr: dress: 0 J 4 Slate License Number• Contact Person: Phone. Phone. Fac: plication is hereby made 10 obtain a permit to do the work and installations as indicated 1 ccrti(y Thal no µ•ork or installation has commenced prior lu tltc iancc of a permit and that all work will be performed to meet standards of all laws regulating construction in Ihts jurisdiction. 1 understand ilia(a separalc mit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS. Wi-LLS, POOLS, FURNACES, 1301L F-RS, I WATERS. TANKS, and t CONDfrLONL"RS, etc. NER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance wnli all applicable laws regulating tstruction and zoning. WARNING TO OWNER: YOUR FAILURE_ TO RECORD A NOTICE OF COMMENCEMENT klAY RISUL f IN YOUR PAYING ICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND -1'0 013TAIN FINANCING. CONSULT WI'fli YOUR LENDER Olt AN TORNEY BEFORE RECORDING YOUR NOTICE OF COMMLNCEMENT. TICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in dtc public records of county, and there may be additional permits required from other governmental entities such as water management districts, state agencies• or federal agencies. cptancc of permit is verification that I will notify the owner of the property of the requirements of Florida le-icn law, FS 713 Signature of 0u nor/Agent Print Ownc/Agent's Name Signature of Notary -State of Florida Owner/Agent is _ Produced ID ROVALS: ZONING: cial Conditions: 03ROOG Personally Known to Me or Date rgnaturc ofCon for/Agent k71111/ SET T F ,& rt,HilSSrrJh O Print Contractor/Agent's Natne 'yk ety 1.6 Date Signature of Notary -State of Florida ' Pa t + r C0507298 Q d9 0. °nwlTM°.yy •Q0 actor/Agcnl is Personally Known toM ia'6L Sot O\\\\\\\\ ontr1_j--Produced 10_Z UrIL: FD: ENG: BLDG: 9-/0z106 r ea000_m_eee_-----.oeaea -___nd__evea_..a_a_e__oe_oo_ave________a__ae_e___e__a______°e__..__ea_.. 3II 7 I PATRICK K. VANDERWYDEN, PLS LAND SURVEYING SERVICES PHONE: ( 407 ) 363 — 7642 E 6419 VINELAND ROAD FAX ( 407 ) 373 — 0330 .; ORLANDO, FLORIDA 32819 1 E (June 15, 2007 1 City of Sanford Building Division P.O. Box 1788 , Sanford, Florida 32772-1788 1 + 1 e RE: Lot 37, Florida Land and Colonization Company's Addition to South Sanford ( Plat Book 1, Page 73) Parcel # 35-19-30-503-0000-0370 + F Permit # 06-1073 , F I e + City of Sanford Building Department; f The finished floor elevation of the single family residence located at 1220 West 16th Street, Lot 37, Florida Land and ; Colonization Company's Addition to South Sanford ( Plat Book 1, Page 73 ), meets or exceeds the requirements set forth ; in the City of Sanford Building Code, Chapter 18, Sections 18 - 4 (a) ; e Sincerely, , I E Patrick K. VanderWyden, PLS, Cert # 5154 3 0 - 1 1 1 1 1 1 ! 1 1 C ! 1 ! i ! E 1I F ! 5 i1 F 1I tl ! C + 1 d 1 I r. ! F ! 5 ! e ! 1 5 - 1 i ! 1 o 0 o a .a PATRICK K. VANDERwYDEN, PLS E LAND SURVEYING SERVICES PHONE: ( 407 ) 363 — 7642 6419 VINELAND ROAD FAX ( 407 ) 373 — 0330 a ORLANDO, FLORIDA 32819 E June 15, 2007 City of Sanford Building Division ; P.O. Box 1788 ; Sanford, Florida 32772-1788 RE: Lot 37, Florida Land and Colonization Company's Addition to South Sanford ( Plat Book 1, Page 73) Parcel # 35-19-30-503-0000-0370 ; Permit # 06-1073 ; City of Sanford Building Department; ; The finished floor elevation of the single family residence located at 1220 West 16th Street, Lot 37, Florida Land and ; Colonization Company's Addition to South Sanford ( Plat Book 1, Page 73 ), meets or exceeds the requirements set forth ; a in the City of Sanford Building Code, Chapter 18, Sections 18 - 4 (a) ; Sincerely, Patrick R. VanderWyden, PLS, Cert # 5154 19 it afth,/01 Permit # : s -17 ti Job Description of Work: Historic District: _ Zoning: CITY OF SANFORD PERMIT APPLICATION Su Date: Total Square Footage / U 7t? Value of Work: $ 3, 76/7. o Permit Type: Building Electrical Mechanical, Plumbing Fire Sprinkler/Alarm Pool Electrical: New Service - # of AMPS Mechanical: Residential Non -Residential Addition/Alteration Chan a of Service Temporary Pole Replacement New (Duct Layout & Energy Calc. Required) Plumbing/ New Commercial: # of Fixtures of Water & Sewer Lines # of Gas Lines Plumbing/New Residential: # of Water Closets Plumbing Repair - Residential or Commercial Occupancy Type: Residential Commercial Construction Type: 1 # of Stories:- Industrial of Dwelling Units: Flood Zone: (FEMA form required) Name 37y3 S, Cyoc7SAddress:( r7e-/I.f//%% lltWtl y A%l'.-Lroo Phone & Fa:3,5pa 33Y- 6?S-157ntaet Person: Bonding Company: Address: Mortgage Leader. . Address: Ambkect/Engineer: Address: Phone: rise Number: 614CL /Sl7-;R liLl/APhone:3. %.ii Phone: Fa:: Application is hereby made to obtain a permit to do the work and installations as indicated. 1 certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER' S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance o it i fits ' t 1 coil otify the owner of the property of the requueme to ' W n Law, FS 713. Sigm o /A Date Sig ontractor/Agent •JG• •rat SCQ cJKy 16 roll N Pri t n ' erne Pnnt or is = Q o iij0 _ 8 0 Signakre of Notary -State of PfQrjb Date Signature of Notary -State of Florida "Art•OQ\ C Ah OF IIIII I IIII\\ Owner/ Agent is _Personally Known to Me or Contractor/Agent is Pers ally nown tome r Produced ID _Produced ID - S - 613- APPROVALS: ZONING: UTIL: FD: ENG: BLDG: Special Conditions: Rev 032006 5- 3.o6 FORM 60OA-2004 EnergyGauge@) 4.0 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: 219RO906 Builder: DoneRight Heat and Air Address: Permitting Office: City, State: Sanford, FL Permit Number: Owner: Jim Walter Homes, The San Antonio Jurisdiction Number: 691500 Climate Zone: Central 1. New construction or existing New 2. Single family or multi -family Single family _ 3. Number of units, if multi -family I _ 4. Number of Bedrooms 3 _ 5. Is this a worst case? No _ 6. Conditioned floor area (ft') 1048 ft' _ 7. Glass type I and area: (Label reqd. by 13-104.4.5 if not default) a. U-factor: Description Area or Single or Double DEFAULT) 7a. Dble Default) 117.9 ft' _ b. SHGC: or Clear or Tint DEFAULT) 7b. Clear) 117.9 ft' _ 8. Floor types a. Raised Wood, Post or Pier R=11.0, 1048.011' _ b. N/A c. N/A 9. Wall types a. Frame, Wood, Exterior R=1 1.0, 940.3 R' _ b. N/A c. N/A d. N/A e. N/A 10. Ceiling types a. Under Attic R=19.0, 1048.0 ft' b. N/A c. N/A 11. Ducts a. Sup: Unc. Ret: Unc. AH: Interior Sup. R=6.0, 192.0 ft b. N/A 12. Cooling systems a. Central Unit b. N/A c. N/A 13. Heating systems a. Electric Heat Pump b. N/A c. N/A 14. Hot water systems a. Electric Resistance b. N/A c. Conservation credits HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HVAC credits CF-Ceiling fan, CV -Cross ventilation, HF-Whole house fan, PT -Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.11 Total as -built points: 17747 PASSTotalbasepoints: 18223 I hereby certify that the plans and specifications covered by this calculation are in compl' ergyAMJLn Code. Y ASW, . INC. PREPARED BY: DATE: 23 d96 I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: Cap: 3 1.0 IcBtu/hr _ SEER: 13.00 Cap: 28.6 IcBtu/hr _ HSPF: 7.10 Cap: 40.0 gallons _ EF: 0.92 1 Predominant glass type. For actual glass type and areas, see Summer & Winter Glass output on pages 2&4. EnergyGauge® (Version: FLRCSB v4.0) FORM 60OA-2004 EnergyGauge® 4.0 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS:, Sanford, FL, PERMIT #: BASE AS -BUILT GLASS TYPES 18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points 18 1048.0 25.78 4863.1 Double, Clear N 1.3 11.0 16.2 26.25 0.99 422.1 Double, Clear E 1.3 5.7 43.5 55.69 0.93 2253.0 Double, Clear S 1.3 5.7 13.5 41.92 0.89 502.3 Double, Clear S 6.0 5.7 13.5 41.92 0.56 316.2 Double, Clear W 1.3 3.7 16.2 50.22 0.84 684.4 Double, Clear W 1.3 5.7 15.0 50.22 0.93 699.9 As -Built Total: 117.9 4877.9 WALL TYPES Area X BSPM Points Type R-Value Area X SPM Points Adjacent 0.0 0.00 0.0 Frame, Wood, Exterior 11.0 940.3 1.90 1786.6 Exterior 940.3 1.90 1786.6 Base Total: 940.3 1786.6 As -Built Total: 940.3 1786.6 DOOR TYPES Area X BSPM Points Type Area X SPM Points Adjacent 0.0 0.00 0.0 Exterior Wood 20.1 7.20 144.7 Exterior 40.2 4.80 193.0 Exterior Wood 20.1 7.20 144.7 Base Total: 40.2 193.0 As -Built Total: 40.2 289.4 CEILING TYPES Area X BSPM Points Type R-Value Area X SPM X SCM = Points Under Attic 1048.0 2.13 2232.2 Under Attic 19.0 1048.0 2.82 X 1.00 2955.4 Base Total: 1048.0 2232.2 As -Built Total: 1048.0 2955.4 FLOOR TYPES Area X BSPM Points Type R-Value Area X SPM Points Slab 0.0(p) 0.0 0.0 Raised Wood, Post or Pier 11.0 1048.0 1.83 1912.6 Raised 1048.0 3.43 3594.6 Base Total: 3594.6 As -Built Total: 1048.0 1912.6 INFILTRATION Area X BSPM Points Area X SPM Points 1048.0 14.31 14996.9 1048.0 14.31 14996.9 EnergyGauge® DCA Form 60OA-2004 EnergyGauge®/FlaRES'2004 FLRCSB v4.0 FORM 60OA-2004 EnergyGauge® 4.0 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS:, Sanford, FL, PERMIT #: BASE AS -BUILT Summer Base Points: 20477.2 Summer As -Built Points: 26818.8 Total Summer X System Cooling Total X Cap X Duct X System X Credit Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points System - Points) DM x DSM x AHU) sys 1: Central Unit 31000 btuh ,SEER/EFF(13.0) Ducts:Unc(S),Unc(R),Int(AH),R6.0(INS) 26819 1.00 1.09 x 1.150 x 0.90) 0.262 1.000 7914.4 20477.2 0.4266 8735.6 26818.8 1.00 1.125 0.262 1.000 7914.4 EnergyGaugeTm DCA Form 60OA-2004 EnergyGauge®/FlaRES'2004 FLRCSB v4.0 FORM 60OA-2004 EnergyGauge® 4.0 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS:, Sanford, FL, PERMIT #: BASE AS -BUILT GLASS TYPES 18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Point 18 1048.0 5.86 1105.4 Double, Clear N 1.3 11.0 16.2 11.00 1.00 177.9 Double, Clear E 1.3 5.7 43.5 8.82 1.02 389.9 Double, Clear S 1.3 5.7 13.5 6.74 1.04 94.6 Double, Clear S 6.0 5.7 13.5 6.74 1.88 171.1 Double, Clear W 1.3 3.7 16.2 9.55 1.02 158.3 Double, Clear W 1.3 5.7 15.0 9.55 1.01 144.4 As -Built Total: 117.9 1136.1 WALL TYPES Area X BWPM Points Type R-Value Area X WPM Points Adjacent 0.0 0.00 0.0 Frame, Wood, Exterior 11.0 940.3 2.00 1880.6 Exterior 940.3 2.00 1880.6 Base Total: 940.3 1880.6 As -Built Total: 940.3 1880.6 DOOR TYPES Area X BWPM Points Type Area X WPM Points Adjacent 0.0 0.00 0.0 Exterior Wood 20.1 7.60 152.8 Exterior 40.2 5.10 205.0 Exterior Wood 20.1 7.60 152.8 Base Total: 40.2 205.0 As -Built Total: 40.2 305.5 CEILING TYPES Area X BWPM Points Type R-Value Area X WPM X WCM = Points Under Attic 1048.0 0.64 670.7 Under Attic 19.0 1048.0 0.87 X 1.00 911.8 Base Total: 1048.0 670.7 As -Built Total: 1048.0 911.8 FLOOR TYPES Area X BWPM Points Type R-Value Area X WPM Points Slab 0.0(p) 0.0 0.0 Raised Wood, Post or Pier 11.0 1048.0 0.47 493.6 Raised 1048.0 0.20 209.6 Base Total: 209.6 As -Built Total: 1048.0 493.6 INFILTRATION Area X BWPM Points Area X WPM Points 1048.0 0.28 293.4 1048.0 -0.28 293.4 EnergyGauge® DCA Form 60OA-2004 EnergyGauge®/FlaRES'2004 FLRCSB v4.0 FORM 60OA-2004 EnergyGauge® 4.0 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS:, Sanford, FL, PERMIT #: BASE AS -BUILT Winter Base Points: 3358.7 Winter As -Built Points: 4434.2 Total Winter X System = Heating Total X Cap X Duct X System X Credit Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points System - Points) DM x DSM x AHU) sys 1: Electric Heat Pump 28600 btuh ,EFF(7.1) Ducts: Unc(S),Unc(R),Int(AH),R6.0 4434.2 1.000 1.078 x 1.160 x 0.92) 0.481 1.000 2452.2 3358.7 0.6274 2107.3 4434.2 1.00 1.150 0.481 1.000 2452.2 EnergyGaugeTm DCA Form 60OA-2004 EnergyGauge®/FlaRES'2004 FLRCSB v4.0 FORM 60OA-2004 EnergyGauge® 4.0 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS:, Sanford, FL, PERMIT #: BASE AS -BUILT WATER HEATING Number of X Multiplier Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 3 2460.00 7380.0 40.0 0.92 3 1.00 2460.00 1.00 7380.0 As -Built Total: 7380.0 CODE COMPLIANCE STATUS BASE AS -BUILT Cooling + Heating + Points Points Hot Water Points Total Points Cooling Points Heating + Hot Water = Total Points Points Points 8736 2107 7380 18223 1 7914 2452 7380 =747 PASS yp THB ST, o. n a c 00 we EnergyGaugeTm DCA Form 60OA-2004 EnergyGauge®/FlaRES'2004 FLRCSB v4.0 FORM 60OA-2004 EnergyGauge® 4.0 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS:, Sanford, FL, PERMIT #: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/sq.ft. window area; .5 cfm/sq.ft. door area. Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility penetrations; between wall panels & top/bottom plates; between walls and Floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from, and is sealed to, the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from conditioned space, tested. Multi -story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. bA-ZZ U I Mt:K YKt,GKIF' 1 IVt MtA5UKt5 (muSL De met or eXCeeaea DV all resicienceS. COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 612.1.ABC.3.2. Switch or clearly marked circuit breaker (electric) or cutoff (gas) must be provided. External or built-in heat trap required. Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1, 602.1 Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. EnergyGaugeTm DCA Form 60OA-2004 EnergyGauge®/FIaRES'2004 FLRCSB v4.0 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 84.2 The higher the score, the more efficient the home. Jim Walter Homes, The San Antonio, , Sanford, FL, 1. New construction or existing New 2. Single family or multi -family Single family _ 3. Number of units, if multi -family 1 _ 4. Number of Bedrooms 3 _ 5. Is this a worst case? No _ 6. Conditioned floor area (ft2) 1048 112 _ 7. Glass type I and area: (Label reqd. by 13-104.4.5 if not default) a. U-factor: Description Area or Single or Double DEFAULT) 7a. (Dble Default) 117.9 ft2 _ b. SHGC: or Clear or Tint DEFAULT) 7b. Clear) 117.9 ft2 8. Floor types a. Raised Wood, Post or Pier R=1 1.0, 1048.0ft2 _ b. N/A c. N/A 9. Wall types a. Frame, Wood, Exterior R=11.0, 940.3 ft2 _ b. N/A c. N/A d. N/A e. N/A 10. Ceiling types a. Under Attic R=19.0, 1048.0 ft2 _ b. N/A c. N/A 11. Ducts a. Sup: Unc. Ret: Unc. AH: Interior Sup. R=6.0, 192.0 ft b. N/A 12. Cooling systems a. Central Unit b. N/A c. N/A 13. Heating systems a. Electric Heat Pump b. N/A c. N/A 14. Hot water systems a. Electric Resistance b. N/A c. Conservation credits HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HVAC credits CF-Ceiling fan, CV -Cross ventilation, HF-Whole house fan, PT -Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New Home: City/FL Zip: Cap: 3 1.0 IcBtu/hr _ SEER: 13.00 Cap: 28.6 kBtu/hr _ HSPF: 7.10 Cap: 40.0 gallons _ EF: 0.92 04-v14s srq oA hat a v a NOTE: The home's estimated energy performance score is only available through the FLARES computer program. This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a US EPA/DOE EnergyStJrm designation), your home may qualify for energy efficiency mortgage (EEM) incentives ifyou obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 321/638-1492 or see the Energy Gauge web site at www.fsec.ucf edu for information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 8501487-1824. I Predominant glass type. For actual glass type and areas, see Summer & Winter Glass output on pa es 2&4. EnergyGauge® (Version: FLEE v4.0) Minneola, FI Job: 219RO906ProjectSummaryDate: Sep 23,2006 Entire House By: FLEA/dn DoneRight Heating and Air For: Jim Walter Homes Sanford, FI Notes: The San Antonio Weather: Orlando, FL, US Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Building heat loss 13633 Btuh Ventilation air 8 cfm Ventilation air loss 233 Btuh Design heat load 13866 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 Heating Cooling Area (ft2) 1049 104 Volume (ft') 8384 8384 Air changes/hour 0.75 0.35 Equiv. AVF (cfm) 105 49 Heating Equipment Summary Make Lennox Trade Model 13HPD-030 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 7.1 HSPF 28600 Btuh @ 47°F 25 OF 1065 cfm 0.078 cfm/Btuh 0.50 in H2O Heat/Cool Summer Design Conditions Outside db 93 OF Inside db 75 OF Design TD 18 OF Daily range Relative humidity M 50 Moisture difference 44 gr/lb Sensible Cooling Equipment Load Sizing Structure 19473 Btuh Ventilation 150 Btuh Design temperature swing 3.0 OF Use mfg. data n Rate/swing multiplier 0.98 Total Sens. equip. load 19231 Btuh Latent Cooling Equipment Load Sizing Internal gains 800 Btuh Ventilation 225 Btuh Infiltration 1446 Btuh Total latent equip. load 3102 Btuh Total equipment load 22333 Btuh Req. total capacity at 0.70 SHR 2.3 ton Cooling Equipment Summary Make Lennox Trade Cond 13HPD-030 Coil CB26UH-030 Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 13 SEER 21700 Btuh 9300 Btuh 31000 Btuh 1065 cfm 0.055 cfm/Btuh 0.50 in H2O 86 Bold/italic values have been manually overridden Printout certified by ACCA to meet all requirements of Manual J 8th Ed. t vregHtsoft Right -Suite Residential 5.9.11 RSR32737 2006-Sep-24 10 47:13 C:\Files\Wdghtsoft J6 Jobs\219R0906.rrp Calc = MJfi Orientation = N Page 1 Right-J Worksheet Entire House may DoneRight Heating and Air Minneola, FI Job: 219R0906 Date: Sep 23, 2006 By: FLEA/dn 1 Room name Entire House Living Room 2 Exposed wall 137.3 ft 26.2 R 3 Ceiling height 8.0 0 d 8.0 ft heat/cool 4 Room dimensions 1.0 x 262.0 ft 5 Room area 1048.0 ft2 262.0 R2 Ty Construction U-value Or HTM Area UP) Load Area (R2) Load number Btuh/ft2-'F) Btuh/R2) or perimeter (R) Btuh) or perimeter (fi) Btuh) Heal Cool Gross N/P/S Heal Cool Gross N/P/S Heat Cool 6 yJ ;' •• 12B-Osw. • :::::., . 0.097 n 2:72 2.79 192 176 477 491' 0 0 0 0 L- G 1D-c2ob'. _ 0:650 n. 18.20 18.87 16 0 295 306 0 0 0 0 y! 12B-Osw 0.097 a 2.72 2.79 368 325 881 907 98 84 228 235 G 1D-c2ob 0.650 a 18.20 57.59 44 3 792 2377 14 1 246 738 11 Vh 12B-Osw .. 0.097 s 2.72 2.79 192 145 394 405 112 78 213 219 ID-c2ob ' 0.650 s 18.20 22.63 14 14 246 255 0 0 0 0 1 D-c2ob 0.650 s 18.20 22.63 14 14 246 255 14 14 246 255 11G0 . ' ;.;.;.:,::;;;!;... 0.540, s§:•: 15.12 16.85 20 20 304 339 20 20 304 339, Val 12B-Osw 0.097 w 2.72 2.79 346 295 801 824 0 0 0 0 G 1D-c2ob 0.650 w 18.20 57.59 16 2 295 854 0 0 0 0 L-Gp 1D-c2ob 0.650 w 18.20 57.59 15 1 273 820 0 0 0 0 11G0 0.540 w 15.12 16.85 20 20 304 339 0 0 0 0 C 16B-19ad . 0.049 1.37 2.68 1048 1048 1438 2809 262 262 359 702 F 20P-11c 0.078 2.18 1.15 1048 137 2289 1202 262 26 572 300 Envelope loss/gain 9034 12181 2168 2788 12 a) Infiltration 3216 965 614 184 b) Ventilation 0 0 0 0 13 Internal gains: Occupants ® 230 4 920 0 0 Appliances ® 1200 1 1200 0 0 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 12250 15265 2782 2972 15 Duct loads 11% 28% 1383 4208 11% 28% 314 819 Total room load 13633 19473 1 3096 3791 Air required (cfm) 1065 1065 242 207 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wr ghtsoft Right -Suite Residential 5.9.11 RSR32737 2006-Sep-24 10:47:13 C:\Files\WrightsoftJ8Jobs\219RO906.rrp Calc = MJB Orientation = N Page 1 Right-J Worksheet0. Entire House DoneRight Heating and Air Minneola. FI Job: 219R0906 Date: Sep 23, 2006 By: FLEA/dn 1 Room name Dining Room Kitchen 2 Exposed wall 24.5 ft 11.0 ft 3 Ceiling height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 100.0 ft 1.0 x 93.0 ft 5 Room area 100.0 ft' 93.0 ft' Ty Construction U-value Or HTM Area (ft2) Load Area (02) Load number Btuh/ft? 'F) Btuh/ft2) or perimeter (ft) Btuh) or perimeter (ft) Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 1y 1213-0sw 0.097 n 2.72 2.79 0 0 0 0 0 0 0 0 G 1D-c2ob 0.650 n 18.20 18.87 0 0 0 0 0 0 0 0 y/ 12B-0sw 0.097 a 2.72 2.79 32 32 87 89 0 0 0 0 G 1D-c2ob 0.650 a 18.20 57.59 0 0 0 0 0 0 0 0 11 Vj/ 126-0sw 0.'097 s ' 2.72 2.79 80 67 181 186 0 0 0 0 1Dc2ob 0.650 s 18.20 22.63 14 14 246 255 0 0 0 0 1D-c2lob 0.650 s. 18.20 22.63 0 0 0 0 0 0 0 0 11G0:. .. 0.540 is 15.12 16.85 0 0 0 0 0 0 0 0 VV II 1213-0sw 0.097 w 2.72 2.79 84 76 206 212 88 80 217 223 G 1D-c2ob 0.650 w 18.20 57.59 8 1 147 427 8 1 147 427 1 D-c2ob 0.650 w 18.20 57.59 0 0 0 0 0 0 0 0 1-Gp 11G0 0.540 w 15.12 16.85 0 0 0 0 0 0 0 0 C 16&19ai1:. 0.049 1:37 2.68 100 100 137 268 93 93 128 249 F 20P-11c 0.078 2.18 1.15 100 25 218 115 93 11 203 107 Envelope loss/gain 1222 1551 695 1006 12 a) Infiltration 574 172 258 77 b) Ventilation 0 0 0 0 13 Internal gains: Occupants Q 230 0 0 0 0 Appliances @ 1200 0 0 1 1200 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1796 1724 953 2283 15 Duct loads 11% 28% 203 475 11% 28% 108 629 Total room load 1999 2199 1060 2913 Air required (cfm) 156 120 83 159 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wrIgF-ftSoTC Right -Suite Residential 5 9 11 RSR32737 2006-Sep-2410:47:13 C:\Files%Wdghtsoft J8 Jobs1219R0906.rrp Calc = MJ8 Orientation = N Page 2 Right-J Worksheet Job: 219R0906 Entire House Date: Sep 23, 2006 DoneRight Heating and Air By: FLEA/dn Minneola, FI 1 Room name Utility Bedroom 1 2 Exposed wall 5.9 fl 26.0 fl 3 Ceiling height 8.0 fl heat/cool 8.0 fl heat/cool 4 Room dimensions 1.0 x 50.0 fl 1.0 x 168.0 fl 5 Room area 50.0 fl2 168.0 fl2 Ty Construction U-value Or HTM Area (fl2) Load Area (fl2) Load number Btuh/fl2 'F) Btuh/R2) or perimeter (fl) Btuh) or perimeter (0) Btuh) Heal Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool Osw 0.097 n ..: 2.72 2.7g •,,.;:::.::: 0 0 0 0 96 E";:':'::88 239 246 1D-c2ob. :.;: . I:0.650 n . 18.20 18.87.: `:3' i:: 0 0 0 0 0 ``::>?:>147 153 yl 12B-Osw 0.097 a 2.72 2.79 0 0 0 0 112 97 263 271 t-G 1D-c2ob 0.650 a 18.20 57.59 0 0 0 0 15 1 273 820 097. 2:72 2.79 :;.>::::;::<:;:;0 0 0 0 0 0 0 0 1D=c2ob 0.650 s' 18.20 22.63 i3O 0 1Dc2ob :' 0:650 s 18:20 2's.63::;.;.;:.:0 0,.;:s:s:::!' 0" 0.:::5;:::>:`0.';':,;::: 0 :: 0 0 11G0::>s >: : ;:.:r 0.540 s;>:: 15'.12 1685 0 r: :>:;,;0 0 i..... VVV lll 12B-Osw 0.097 w 2.72 2.79 47 27 74 76 0 0 0 0 1D-c2ob 0.650 w 18.20 57.59 0 0 0 0 0 0 0 0 1D-c2ob 0.650 w 18.20 57.59 0 0 0 0 0 0 0 0 11G0 0.540 w 15.12 16.85 20 20 304 339 0 0 0 0 C;»:;:>:< e;: 16B,19ad:;... ..::::.. 0.049 1.37.:2.68 50 50.':.168 168 230 ts3>?<450 F 20P-11c 0.078 2.18 1.15 50 6 109 57 168 26 367 193 Envelope loss/gain 1 555 6061 15201 2132 12 a) Infiltration 138 41 609 183' b) Ventilation 0 0 0 0, 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances @ 1200 0 0 0 0 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 693 647 2129 2775 15 Duct loads 11% 28% 78 178 11% 28% 240 765 Total room load 772 826 2369 3540 Air required (cfm) 60 45 185 194 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wtrrfgF tSofC Right -Suite Residential 5.9.11 RSR32737 2006-Sep-24 10:47:13 C:tFileslWrightsoft J8 Jobst219R0906.rrp Calc = MJ8 Orientation = N Page 3 Right-J Worksheet Entire House dry. DoneRight Heating and Air Minneola, FI Job: 219RO906 Date: Sep 23, 2006 By: FLEA/dn 1 Room name Bath 1 WIC 2 Exposed wall 5.4 0 0.0 R 3 Ceiling height 8.0 ft heat/cool 8.0 R heat/cool 4 Room dimensions 1.0 x 43.0 ft 1.0 x 21.0 R 5 Room area 43.0 1`12 21.0 f12 Ty Construction U-value Or HTM Area (W) Load Area (02) Load number Btuh/ft2-'F) Btuh/fl2) or perimeter (0) Btuh) or perimeter (ft) Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 yI "• 128-0sw 0.097 n, 2.72. 2.79 0 0 0 0 0 0 0 0 a ID-c2ob::" .. 0.'650 n 18.20 18.87 0. 0 0 0 0 0 0 0 yl 12B-Osw 0.097 a 2.72 2.79 43 43 117 121 0 0 0 0 1---G ID-c2ob 0.650 a 18.20 57.59 0 0 0 0 0 0 0 0 11 1213-0svr 0.097 s 2.72 2.79 0 0 0 0 0 0 0 0 G ID-c2ob 0.650 s 18.20 22.63 0 0 0 0 0 0 0 0 G' 1Dc2ob 0:650 s 18.20 22.63 0 0 0 0 0 0 0 0 DD 11G0. 0.540 s 15.12 16.85 0. 0 0 0 b 0 0 0 VV 12B-Osw 0.097 w 2.72 2.79 0 0 0 0 0 0 0 0 G 1D-c2ob 0.650 w 18.20 57.59 0 0 0 0 0 0 0 0 1D-c2ob 0.650 w 18.20 57.59 0 0 0 0 0 0 0 0 I-Gp 11GO 0:540 w 15.12 16.85 0 0 0 0 0 0 0 0 C....: 16B-19ad 0.049 1.37 2.68.. 43 43 59 1.15 21 21 29 56 F 20P-11c 0.078 2.18 1.15 43 5 94 49 21 0 46 24 Envelope loss/gain 270 285 75 80 12 a) Infiltration 126 38 0 0 b) Ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 1200 0 0 0 0 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 397 323 75 80 15 Duct loads 11% 28% 45 89 11% 28% 8 22 Total room load 441 412 83 103 Air required (cfm) 34 23 6 6 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wr g"tsoft Right -Suite Residential 5.9.11 RSR32737 2006Sep-2410:47:13 C:\Files\Wdghtsoft J8 Jobs\219RO906.rrp Calc = MJ8 Orientation = N Page 4 Right-J Worksheet0. Entire House DoneRight Heating and Air Minneola, FI Job: 219RO906 Date: Sep 23, 2006 By: FLEA/dn 1 Room name Bedroom 2 Bath 2 2 Exposed wall 22.5 ft 5.4 ft 3 Ceiling height 8.0 0 heat/cool 8.0 0 heat/cool 4 Room dimensions 1.0 x 142.0 ft 1.0 x 45.0 ft 5 Room area 142.0 02 45.0 W Ty Construction U-value Or HTM Area (w) Load Area (W) Load number Btuh/ft? 'F) Btu ft) or perimeter (ft) Btuh) or perimeter (ft) Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 VL_I 12B=0sw ID-c2ob 0.097 0.650 n n 2.72 18.20 2.79 18.87 96 8 88 0 239 147 246 153 0 0 0 0 6 0 0 0 V I 12B-0sw 0.097 a 2.72 2.79 0 0 0 0 0 0 0 0 1D-c2ob 0.650 a 18.20 57.59 0 0 0 0 0 0 0 0 11 VEI 12B-0sw 0.097 s 2.72 2.79 0 0 0 0 0 0 0 0 1D-c2ob 0.650 s 18.20 22.63 0 0 0 0 0 0 0 0 1 D=c2ob =• 0.650 s 18.20 22.63 0 0 0 0 0 0 0 0 11G0 0.540 s 15.12, 16.85 0 0 0 0 0 0 0 0 VV II 12B-Osw 0.097 w 2.72 2.79 84 69 187 193 43 43 117 121 G ID-c2ob 0.650 w 18.20 57.59 0 0 0 0 0 0 0 0 1D-c2ob 0.650 w 18.20 57.59 15 1 273 820 0 0 0 0 I-Gp 11G0 0.540 w 15.12 16.85 0 0 0 0 0 0 0 0 C. 1613-19ad ... 0.049 1.37 2,68.:. 142 142 195 381 45 45 62 121 F 20P-11c 0.078 2.18 1.15 142 23 310 163 45 5 98 52 Envelope loss/gain 1352 1954 277 293 12 a) Infiltration 527 158 126 38 b) Ventilation 0 0 0 0 13 Internal gains: Occupants ® 230 1 230 0 0 Appliances ® 1200 0 0 0 0 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1878 2342 404 331 15 Duct loads 11% 28% 212 646 11% 28% 46 91 Total room load 2091 2988 449 422 Air required (cfm) 163 163 35 23 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wr140h1t5o1Ft Right -Suite Residential 5.9.11 RSR32737 2006-Sep-24 10:47:13 k-45A C:\Files\Wrightson J8 JobsN219RO906.rrp Calc = MJ8 Orientation = N Page 5 Right-J Worksheet Entire House DoneRight Heating and Air Minneola, FI Job: 219RO906 Date: Sep 23, 2006 By: FLEA/dn 1 Room name Bedroom 3 2 Exposed wall 10.4 ft 3 Ceiling height 8.0 ft heat/cool 4 Room dimensions 1.0 x 124.0 0 5 Room area 124.0 ft' Ty Construction U-value Or HTM Area (W) Load Area Load number Btuh/Rz-*F) Btu /01) or perimeter (ft) Bt h) or perimeter Heat Coal Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 12B-Osw 0.097 n 2.72 2.79 0 0 0 0 L --- G, I D-c2ob 0.650 n. 182 183T 0 0 0 00 t_r. 1213-0sw 0.097 e 2.72 2.79 83 68 185 191 1D-c2ob 0.650 e 18.20 57.59 15 1 273 820 11 V 1213-0sw 0.097 i 2.72 2.790 0 0 0 1D-c2ob 0.650 s 18.20 22.63 0 0 0 0b1p-c2ob 0.650 s 18.20 22.63 0 0 0 11GO: 0.540 s 15AZ 16.85 0 0 V-0 0 Vh12B-Osw 0.097 w 2.72 2.79 0 0 0 0 1D-c2ob 0.650 w 18.20 57.59 0 0 0 0 1D-c2ob 0.650 w 18.20 57.59 0 0 0 0 11GO 0.540 w 15.12 16.85 0 0 0 0 C 116B-19acl. 0.049 1.37 2.68 124 124 170 332 F 20P-1 1c 0.078 2.18 1.15 124 10 271 142 Envelope losstgain 899 1485 12 a) Infiltration 244 73 b) Ventilation 0 0 13 Internal gains: Occupants @ 230 1 230 Appliances @ 1200 0 0 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 1143 1788 15 Duct loads 11% 28% 129 493 Total room load 1272 22111 Air required (cfm) 99 125 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. HtSC>T-t Right -Suite Residential 5.9.11 RSR32737 2006-Sep-24 10:47:13 C:\Files%Wdghtsoft J8 Jobs\219RO906.rrp Calc = MJ8 Orientation = N Page 6 Minneola, FI Duct System Summary Entire House DoneRight Heating and Air For: Jim Walter Homes Sanford, FI External static pressure Pressurelosses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0.12 in H2O 0.38 in H2O 0.30 / 0.08 in H2O 0.100 in/100ft 1065 cfm 401 ft Job: 219RO906 Date: Sep 23, 2006 By: FLEA/dn Cooling 0.50 in H2O 0.12 in H2O 0.38 in H2O 0.30 / 0.08 in H2O 0.100 in/100ft 1065 cfm Name Design Btuh) Htg cfm) Clg cfm) Design FIR Diam in) Rect Size (in) Duct Mat! Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Bedroom 1 -A c 1770 0 97 0.100 7 Ox 0 VIFx 41.0 275.0 st4 Living Room -A c 1896 0 104 0.100 7 Ox 0 VIFx 41.0 275.0 st2 Living Room c 1896 0 104 0.100 7 Ox 0 VIFx 41.0 275.0 st2 Dining Room c 2199 0 120 0.100 7 Ox 0 VIFx 41.0 275.0 st2 Kitchen c 2913 0 159 0.100 8 Ox 0 VIFx 41.0 275.0 st2 Utility c 826 0 45 0.100 5 Ox 0 VIFx 41.0 275.0 st3 Bedroom 1 c 1770 0 97 0.100 7 Ox 0 VIFx 41.0 275.0 st4 Bath 1 c 412 0 23 0.100 4 Ox 0 VIFx 41.0 275.0 st3 WIC c 103 0 6 0.100 4 Ox 0 VIFx 41.0 275.0 st4 Bedroom 2 c 2988 0 163 0.100 8 Ox 0 VIFx 41.0 275.0 st4 Bath 2 c 422 0 23 0.100 4 Ox 0 VIFx 41.0 275.0 st3 Bedroom 3 c 2281 0 125 0.100 7 Ox 0 VIFx 41.0 275.0 st3 Trunk Htg Clg Design Veloc Diam Rect Duct Duct Name Type cfm) cfm) FIR fpm) in) Size (in) Material Trunk st2 Peak AVF 0 487 0.100 620 12 0 x 0 VinlFlx st1 st3 Peak AVF 0 578 0.100 541 14 0 x 0 VinIFIX st1 st4 Peak AVF 0 363 0.100 665 10 0 x 0 VinIFIX st3 st1 Peak AVF 0 1065 0.100 533 18 16 x 18 RectFbg P P Peak AVF 0 1065 0.100 533 18 16 x 18 RectFbg Sold/italic values have been manually overridden 6i. wrighjtsoft Right -Suite Residential 5.9.11 RSR32737 2006-Sep-24 10:52 56 ACCiA C.Tiles\Wrightsott J8 Jobs1219R0906 rrp Calc = MJ8 Orientation = N Page 1 Name Grill Size (in) Htg cfm) Clg cfm) TEL ft) Design FIR Veloc fpm) Diam in) RectSize in) Stud/Joist Opening (in) Duct Matl Trunk rb1 24x 21 0 1065 85.0 0.100 603 18 0x 0 VIFx rt1 Trunk Htg Clg Design Veloc Diam Rect Duct Duct Name Type cfm) cfm) FIR fpm) in) Size (in) Material Trunk rt1 Peak AVF 0 1065 0.100 548 18 14 x 20 RectFbg R R Peak AVF 0 1065 0.100 548 18 14 x 20 RectFbg wrightsoft Right -Suite Residential5.9.11 RSR32737 2006-Sep-2410:52:56 C:Tiles\Wdghtsoft A Jobs\219R0906.rrp Calc = MJ6 Orientation = N Page 2 BEDROOM 2 BEDROOM 1 97 CFM 12 X 6 7• 1 WAY 163 CFM 12 X 6 1 WAY 8' 10' BATH 2 23 CFM 4' 8 X 4 1 WAY 50 CFM EXH FAN* 97 CFM 12 X 6 7' 1 WAY 11- 6 CFM 8 X 4 10' 1 WAY WIC UTIL 14' 45 CFM 10 X 6 14' 1 WAY 5' 12 KITCHEN 159 CFM 10 x 10 4 WAY N. 7' 120 CFM 10 X 10 4 WAY DINING BATH 1 24 CFM 8 X 4 4' 1 WAY 50 CFM EXH FAN 7%125 CFM 12 X 6 1 WAY 12' 7' 104 CFM 10 X 10 4 WAY BEDROOM 3 104 CFM 10 X 10 4 WAY LIVING ROOM NOT TO SCALE LEGEND CIELING SUPPLY AIR DIPrUSER CIELING RETURN AIR DITfUSER SIDE -WALL OR I WAY DITPUSER SOLID LINE- SUPPLY TRUNK BROKEN LINE- RETURN TRUNK BALANCING DAMPER OR DOD lle- CEILING EXHAUST PAN r/D PIRE DAMPER SCD-PR 3NR. RATING O/A OUTSIDE AIR JIM WALTER HOME THE SAN ANT NI SUPPLY LAYOUT BATH 2 50 CFM I EXH FAN UTIL. JO BEDROOM 1 RETURN 10 X 8 THRU WALL m RETURN 12' 12 X 12 HOP OVER I WIC RETURN 10 X 6 THRU WALL cxc BATH 1 50 CFM ~ EXH FAN BEDROOM 3 LIVING ROOM NOT TO SCALE LEGEND CIELING SUPPLY AIR DIFFUSER CIELING RETURN AIR DIFFUSER SIDE -WALL OR I WAY DIFFUSER SOLID LINE- SUPPLY TRUNK BROKEN LINE- RETURN TRUNK BALANCING DAMPER OR OBD 9 CEILING EKNAUST FAN P/D FIRE DAMPER SCD-PR 3HR. RATING O/A OUTSIDE AIR JIM WALTER HOME THE SAN ANT NI RETURN LAYOUT CITY OF SANFORD PERMIT APPLICATION / I Permit # :_\Q J 1 (:)--)I Date: M / / Job Address: I Z L O W )(00, yT, ^RECEIVED Description of Work: CONljtt`UCT pJ iJSr F l 2005 Historic District: Zoning: lue of Work: S g CO 0 Permit Type: Building Electrical Mechanical Plumbing Fire Sprinkler/Alan^ Pool Electrical: New Service — # of AMPS Addition/Alteration Change of Service Temporary Pole Mechanical: Residential Non -Residential Replacement New (Duct Layout & Energy Calc. Required) Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lines Plumbing/New Residential: # of Water Closets Plumbing Repair — Residential or Commercial Occupancy Type: Residential —,/-- Commercial Industrial Total Square Footagea._ Construction Type: _gn/H. 1 C # of Stories: # of Dwelling Units: Flood Zone: (FEMA form required for other than X) 3s•/J-30-SoS-06200- 0370 Parcel q: (Attach Proof of Ownership & Legal Description) Owners Name & Address: lkhN ErTC S/t•(.SrH 3-7y3 5ARutM418 4r-CoJ yulhN AL0;6e 09a7n , \) A aa323 Phone: - 167 19-5102 91 Contractor Name & Address: J9 H() W _C"1W_:Q L W, Oz 1.41-1a) c , .3 8 State License Number: 7)-14' Phone & Fax: -407- _• 6 4 S U ga-35)•- a 3 K< Contact Person: _/.JLif_fL`%rd -> Phone: X07-3_1,5--0 q 9 / T r Bonding Company: !Q / S{ Address: 1V/)q Mortgage Lender - Address: Architect/ Engineer. JAM-C CAJ 65 LYs1[t'fN 6 Phone: 3 39 Address: P.D . % -t'm M Yl3 3 01 Fax: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER' S AFFIDAVIT: 1 certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS 1'0 YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTI E: In addition to the requirIftits of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county and thereAnay be addilonkl permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of p n crificatioV1ha will notify the owner of the property of the require7ts of Florid ien Law, FS 71 AMA 12- igna r of(&ner/ t Date Signature of Cont ctor/Agent Date Print O cr t Pri t Contractor/Agent's Namme A) S S* 44 if N(ft %ijrF VE Date Sig annvo f totarp-St Date My COMMISSI OtN# DD 164280 DEBBIE BLANTON EXPIRES: November 12, 2006 PA' COMMISSION # DD t t38491 EXPIRED Fa n 7 cnt _ o Me or ( r Co trma todAgent is Pera hyfl y IC t w to or roduced ID t; f/) b1 rdUccd ID r' vofi p;- .q C J7 APPLICATION APPROVED BY: Bldg: Zon Utilities: / FD: Initial • D e) (Ingial & te) (initial & Date) (Initial & Date) Special Conditions: LITIJ17Y IMPACT FEES e&_ 0111, 73 Sty A Z4 S_o I iU48.00 + n5•ou + 16.00 i 1 7 149.OU*i 1 +048 • X 40• _ 41 92r•UO 85• X 18• = 17530.00 * 16• X 18• _ 288.00 417920.00 f 1 75O-00 + V 248.00 + 431' 133.00*+ 1049- 2• _ 574. 50 74. 50 X 0. 01 = 5 • ' 15 5• 74 + 5. 75 + 11. 49*+ Seminole County Property Appraiser Get Information by Parcel Number Page 1 of 1 i2E• 14.0V. T DAViD JOHN90N. CFA. ASA 60.A 5 .APROPERTYryya? z121 6.0 28.0 28.0 a 56.A APPRAISER _ FFM- SEMINOLE COUNTY FL_ 1101 E. R RST ST SANFORD . 277-146B 9 a4. 0-i , a31,3 33A 30 2006 WORKING VALUE SUMMARY GENERAL Value Method: Market Parcel Id: 35-19-30-503-0000-0370 Number of Buildings: 0 Owner: SMITH BERNETTE O Depreciated Bldg Value: $0 Mailing Address: 3743 SHANNONS GREEN WAY Depreciated EXFT Value: $0 City,State, ZipCode: ALEXANDRIA VA 22309 Land Value (Market): $6,953 Property Address: 16TH ST W Land Value Ag: $0 Subdivision Name: FLA LAND AND COLONIZATION COS ADD TO SOUTH SANFORDJust/Market Value: $6,953 Tax District: S1-SANFORD Assessed Value ( SOH): $6,953 Exempt Value: $ 0 Exemptions: Dor: 00- VACANT RESIDENTIAL Taxable Value: $ 6,953 Tax Estimator SALES 2005 VALUE SUMMARY Deed Date Book Page Amount Vac/Imp Qualified WARRANTY DEED 03/2005 05682 0415 $12,000 Vacant Yes 2005 Tax Bill Amount: $139 QUIT CLAIM DEED 03/1980 01284 1660 $9,300 Improved No 2005 Taxable Value: $6,953 QUITCLAIM DEED 02/1980 01284 1659 $100 Improved No DOES NOT INCLUDE NON -AD VALOREM ASSESSMENTS Find Comparable Sales within this Subdivision LAND LEGAL DESCRIPTION Land Unit Land PLATS: Pick... Land Assess Method Frontage Depth Units Price Value LEG LOT 37 FLA LAND + COLONIZATION FRONT FOOT & 50 150 . 000 135.00 $6,953 COS ADD TO SOUTH SANFORD DEPTH PB 1 PG 73 NOTE: Assessed values shown are NOT certified values and therefore are subject to change before being finalized for ad valorem tax purposes. If you recently purchased a homesteaded property your next ear's property tax will be based on Just/Market value. http://www. scpafl.orglplslweblre_web.seminole_county_title?PARC L=35193050300000370&cbparcel=... 1 /5/2006 d/m ;5a/Ner NOME9 CUSTOMER NAME: BERNETTE O SMITH PHONE: 703-799-5329 ADDRESS: W. 16TH STREET SANFORD, FL 111 l 1 SIZE & MODEL HOUSE: 1w SAN ANTONIO SALESPERSON: Linda Supplee DATE: 04/25/2005 DIRECTIONS WEST 16TH STREET, SANFORD, FLORIDA HWY 46 TO SANFORD, RIGHT ON AIRPORT BLVD LEFT ON 18TH STREET- LEFT ON SOUTHWEST ROAD- RIGHT ON 16TH STREET- EAST 1/4 TO 1/2 MI- PROPERTY ON LEFT IN FRONT OF GOLDSBORO ELEMENTARY SCHOOL. SIGNED (MANAGER OR CONST. MANAGER) DATE SALES SYSTEM FORM 296C HMT ENGINEERING, INC. P.O. BOX 18573 TAMPA, FL 33679 Copyright 2000 by Tondelli Engineering, P.A. Tampa, Florida CUSTOMER : JIM WALTER HOMES, INC. JOB NUMBER 2212 DESCRIPTION SAN ANTONIO MODEL DESIGN WIND LOADS MAIN WIND FORCE RESISTING SYSTEMS WIND VELOCITY = 120 MPH EXPOSURE CATEGORY = B BUILDING CATEGORY = 2 IMPORTANCE FACTOR = 1.00 Kzt = 1.00 GUST FACTOR = 0.85 BUILDING DIMENSION NORMAL TO WIND DIRECTION = 46.0 FT BUILDING DIMENSION PARALLEL TO WIND DIRECTION = 24.0 FT MEAN ROOF HEIGHT = 15.0 FT Kh = 0.575 qh = 21.2 PSF DISTANCE, Z = 10.0 FT Kz = 0.575 qz = 21.2 PSF ROOF SLOPE = 5.00 : 12 (22.62 DEG) ROOF WIND LOADS NORMAL TO RIDGE - WINDWARD Cp = 0.27 A ID PgF )) -J II f , T 7. d) P = 8 . PSF, 11 PSF, GCpi GCpi 0. 18 0. 18I P 1 . a•-P)C l)(.o 1Z 35r Cp = 0.22 P = 0.1 PSF, GCpi 0.18 P = 7.7 PSF, GCpi = 0.18 LEEWARD Cp = 0.60 P = 14.6 PSF, GCpi 0.18 d L) D ' 3 s s 0 k' P = 7 . 0 PSF, GCpi 0.18 PARALLEL TO RIDGE - 0 TO H/2 Cp = 1.00 HORIZ. DISTANCE -j- P = 21.8 PSF, GCpi 0.18 FROM WINDWARD EDGE P = 14.2 PSF, GCpi 0.18 w w H/2 TO H Cp = 0.85 e a W a P = 19. 1 PSF, GCpi 0.18 P 11.5 PSF, GCpi 0.18 H TO 2H Cp 0.55 W x P 13.7 PSF, GCpi 0.18 E"' m vw, P 6.1 PSF, GCpi 0.18 a 2H Cp 0.40 P 11.0 PSF, GCpi 0.18 P 3.4 PSF, GCpi 0.18 Some of the above values may be reduced due to the applicable area. Nov 0 2005 HMT ENGINEERING, INC. P.O. BOX 18573 TAMPA, FL 33679 Copyright 2000 by Tondelli Engineering, P.A. Tampa, Florida CUSTOMER : JIM WALTER HOMES, INC. JOB NUMBER 2212 DESCRIPTION SAN ANTONIO MODEL DESIGN WIND LOADS 2IZ COMPONENTS AND CLADDING WIND VELOCITY = 120 MPH EXPOSURE CATEGORY = B BUILDING CATEGORY = 2 IMPORTANCE FACTOR = 1.00 Kzt = 1.00 ROOF SLOPE = 5.00 : 12 (22.62 DEG) TRIBUTARY AREA = 192.0 FT2 MEAN ROOF HEIGHT = 15.0 FT Kh = 0.701 DISTANCE, Z = 10.0 FT Kz = 0.701 WIND LOADS WALL AREA 4 5 GCp (+) 0.773 0.773 GCp (-) 0.873 0.947 PRESSURE psf ) 24.6 24.6 SUCTION psf) 27.2 29.1 a 4 5 a 4 b 7 qh = 25.8 PSF qz = 25.8 PSF P G gh[(GCp) - (GCpi)] Cpi = ± 0.18 BUILDING WIDTH = 24.0 FT CORNER DISTANCE, a = 3.0 FT r u : (R Ps-C g Z)(Z a19 f HMT ENGINEERING, INC. gkfA Jw 4.aG' PO BOX 18573 TAMPA, FL 33679 813) 839-4498 0 HOSEIN H. TAHERI - PE 43424 a7I q a k N 0 2005 POWER Of- LTTORNEX Date: do herby authorize S to pull the ` \ permit fo Type pertrut job address signature Notary Personally OrAivers license # State of Florida, County.o , on ' day of Aw OiW Humph Cor un(i on 00132t, F-"W rs SePtemb ft 23. 2ppe I'A"aV1% t,' :..i"iwltiida This instrument prepa ed by: Name Address Permit # Folio # NOTICE OF COMMENCEMENT State of Florida County of The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement: 1. Property Legal Description ® Lot Unit []Block BldgSubdivision/Condominium Lengthy Legal, please see description attached hereto M"' YANNE F4tlR`.st:, 11Etttt t' UIRL'UIT UORT SENIN011 CUIIP Y Bit 06120 Rg 1742; 0 ") CLERK'S # Z'00&(Q'41&6 RECURDI;D 08/14/'1X 11:31:,8 pa RE01i2!)IW t-115 iti.i REG` MI)!_0 BY t holiien 'ra"'Am COPY space above reserved for 1 irll 1 1 OWN 2. General Description of NEW HOME CONSTRUCTION - SINGLE FAM LY DWE LNGImprovement: 3. Property Owner Name: N, Mailing Address: and interest in property: 1`i"' `Z' FEE SIMPLE Name/mailing address of fee simple title holder if N/A other than owner: N/A 4. Contractor name: MARVIN G. SMITH Address: P.O. BOX 585037 ORLANDO FLORIDA 32858 Phone Number: 407-295-0981 Fax#: (optional- if service by fax is acceptable) 407-578-0471 5. If Surety Bond, Name: TRAVELERS SECURITY and address of Surety: ONE TOWER SQUARE HARTFORD CT 06183 9062andamountofBond: Phone Number: Copy of bond must be attached to this Notice at time of recording) Fax#: (optional -if service by fax is acceptable) 6. Lender name: JIM WALTER HOMES INC Address: PO_ ROX 25037 ORLANDO Phone Number: FLORIDA 1?898 407 295 0981 Fax#: (optional- if service by fax is acceptable) 407-578-04717_ Persons within the State or other documents may of Florida (names and addresses) designated by property owner upon whom NoticesbeservedasprovidedbySection713.13(1)(A)7., Florida Statutes: Name: Address: P.O. BOX 585037 ORLANDO FLORIDA 32858 Phone Number: _407-295-0981 Fax#: (optional- if service by fax is acceptable)_ 407-578-0471 8, In addition to himself, Owner desiggnates the following person(s) to receive a copy of the Lienor's Notice asprovidedbySection713.13(1)(B), Florlda Statutes: Name: Address: P.O. BOX 585037 ORLANDO FLORIDA 32858PhoneNumber: 4 - - Fax#: (optional- if service by fax is acceptable) 407-578-0471 9. Expiration date of th' ( Expires one year from date recorded unless a different date is specified) Ownerslgnature: Owner signature: Printed name: Printed name: SWORN TO AND SUBSCRIBED before me this day of ,.-j, 200 b personally known to me or produced as identification. Notary signature: \ c Printed name: My commission expires: seal: ...... _. Meche1e VAU .0Aes dsy Commission00 5 522 23 2006 yExpires September o, F space above this line reserved for use of the recording oMBo .......... Name Jim Walter Homes P. O. Box 585037 Returnrecordeddocumentto: Address Orlando FL 32858 POWER OF ATTORNEY Date: -ta - Is • cio z5(I, _ , \ / ` , do herby authorize r to pulltheSF R--- permit for 12 11 r Type of permit Q av2nSignature r Notary job address Personally known to me or drivers license # , State of Florida, County of on day of 20Zk Q a HMT ENGINEERING, INC. P.O. BOX 18573 TAMPA, FL 33679 Copyright 2000 by Tondelli Engineering, P.A. Tampa, Florida CUSTOMER : JIM WALTER HOMES, INC. JOB NUMBER 2212 DESCRIPTION FOXBOROUGH MODEL DESIGN WIND LOADS MAIN WIND FORCE RESISTING SYSTEMS WIND VELOCITY = 120 MPH EXPOSURE CATEGORY = B BUILDING CATEGORY = 2 IMPORTANCE FACTOR = 1.00 Kzt = 1.00 GUST FACTOR = 0.85 BUILDING DIMENSION NORMAL TO WIND DIRECTION = 32.0 FT BUILDING DIMENSION PARALLEL TO WIND DIRECTION = 30.0 FT MEAN ROOF HEIGHT = 22.0 FT Kh = 0.641 qh = 23.6 PSF DISTANCE, Z = 25.0 FT Kz = 0.665 qz = 24.5 PSF ROOF SLOPE = 10.00 : 12 (39.81 DEG) ROOF WIND LOADS NORMAL TO RIDGE - WINDWARD : Cp = 0.05 r 7•0 P = 5.2 PSF, GCpi 0.18 ps F P = 3.3 PSF, GCpi 0.18 Cp = 0.40 To)( ' P = P = 3.8 PSF, 12.3 GCpi PSF, GCpi 0.18 0.18 s.w o'j by,EEWARD : Cp 0.60 D ae)(a•86) ; Epp ?,6q P 16. 3 PSF, GCpi 0.18 U „ P 7.8 PSF, GCpi 0.18 PARALLEL TO RIDGE - 0 TO H/2 Cp 1.09 ra a HORIZ. DISTANCE P 26.1 PSF, GCpi 0.18 FROM WINDWARD EDGE P 17.6 PSF, GCpi 0.18 d w z Fo o H/2 TO H Cp 0.81 o P 20.5 PSF, GCpi 0.18 z P 12.0 PSF, GCpi 0.18 0 H TO 2H : Cp 0.59 P 16.2 PSF, GCpi 0.18 P 7.7 PSF, GCpi 0.18 2H : Cp 0.49 P 14.0 PSF, GCpi 0.18 P 5.5 PSF, GCpi 0.18 Some of the above values may be reduced due to the applicable area Nov 0 3 2005 HMT ENGINEERING, INC. P.O. BOX 18573 TAMPA, FL Copyright 2000 by Tondelli Engineering, CUSTOMER : JIM WALTER HOMES, INC. JOB NUMBER 2212 DESCRIPTION FOXBOROUGH MODEL 33679 P.A. Tampa, Florida DESIGN WIND LOADS COMPONENTS AND CLADDING *** WIND VELOCITY = 120 MPH EXPOSURE CATEGORY = B BUILDING CATEGORY = 2 IMPORTANCE FACTOR = 1.00 Kzt = 1.00 ROOF SLOPE = 10.00 : 12 (39.81 DEG) TRIBUTARY AREA = 480.0 FT2 MEAN ROOF HEIGHT = 22.0 FT Kh = 0.701 DISTANCE, 7 = 25.0 FT Kz = 0.701 WIND LOADS WALL AREA 4 5 GCp (+) 0.703 0.703 GCp (-) 0.803 0.806 PRESSURE psf) 22.8 22.8 SUCTION psf) 25.4 a 4 5 a 4 b 0 qh = 25.8 PSF qz = 25.8 PSF P G BUILDING WIDTH = 30.0 FT CORNER DISTANCE, a = 3.0 FT I, r G-d (,),5" -c' Tu = HMT ENGINEERING, INC. A. r,,e/ PO BOX 18573 TAMPA, FL 33679 813) 839.4498 Nov Dkt.% tJX Ofa c. # 10SE1N H. TAHERI - PE 43424 3 2p S 3846 > 32 6. K. 12/1/2005 3:51 PM FROM: Fax Southern Energy Eval Srvice TO: 1-407-578-0471 PAGE: 001 OF 001 FORM 60OA-2004 EnergyGauge@ 4.0 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: 1128511 Builder: 4imWalter Homes Address: West 16th Street Permitting Office:Ah or'd City, State- Sanford, FI Permit Number: J2 - \Q13 Owner: Smith Jurisdiction Number: 1A1500 Climate Zone: Central 1. New construction or existing New - 2. Single family or multi -family Single family _ 3. Number of units, if multi -family 1 _ 4. Number of Bedrooms 3 - 5. Is this a worst case? No _ 6. Conditioned floor area (RI) 1048 ft2 - 7. Glass typel and area: (Label reqd by 13-104.4.5 if not default) a. U-factor: Description Area or Single or Double DEFAULT) 7a.(Dble Default) 145.9 fN - b. SHGC: or Clear or Tint DEFAULT) 7b. Clear) 151.9 f:2 - 8. Floor types a. Raised Wood, Post or Pier R=1 1.0, 1048.3fN - b. N/A c. N/A 9. Wall types a. Frame, Wood, Exterior R=11.0, 901.6 ft2 - b. N/A c. N/A d. N/A e. N/A 10. Ceiling types a. Under Attic R=19.0, 1048.3 ft2 b. N/A c. N/A 11. Ducts a. Sup: Unc. Ret Con. AH: Interior Sup. R=6.0, 40.0 ft b. N/A 12. Cooling systems a. Central Unit b. N/A c. N/A 13. Heating systems a. Electric Heat Pump b. N/A c. N/A 14. Hot water systems a. Electric Resistance b. N/A c. Conservation credits H R-Heat recovery, Solar DHP- Dedicated heat pump) 15. HVAC credits CF- Ceiling fan, CV -Cross ventilation, HF- Whole house fan, PT - Programmable Thermostat, M7_- C-Multizone cooling, M7_- H-Multizone heating) Glass/ Floor Area: 0.14 Total as -built points: 17950 PASS Totalbasepoints: 18189 I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: _ ,lj\(C. DATE: la/ I OS 1 hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/ AGENT: DATE: 1 ZI S L- Cap: 24.0 kBtu/hr - SEER: 12.00 - Cap- 22.0 kBtu/hr - HSPF: 7.80 Cap: 40.0 gallons - EF: 0.92 - PT' - Review of the plans and E S74 specifications covered by this ti0 _ Foy calculation indicates compliance with the Florida Energy Code.,' Before construction is completed a this building will be inspected for 9 compliance with Section 553.908 Florida Statutes. coo WME O BUILDING OFFICIAL: PLAN DATE: Cily OFc A L rnnn 1 Predominant glass type. For actual glass type and areas, see Summer & Winter Glass output on pages 2&4. EnergyGauge® ( Version: FLRCSB v4.0) 12/1/2005 3:52 PM FROM: Fax Southern Energy Eval Srvca TO: 1-407-578-0471 PAGE: 001 OF 001 Summary Energy Code Results Residential Whole Building Performance Method A Smith Project Title: Class 3 Rating West 16th Street 1128511 Registration No. 0 Sanford, FI Climate: Central 12/1 /2005 Building Loads Base As -Built Summer: 20445 points Summer: 27346 points Winter: 3326 points Winter: 4909 points Hot Water: 6790 points Hot Water: 6790 points Total: 30561 points Total: 39045 points Energy Use Base As -Built Cooling: 8722 points Cooling: 8244 points Heating: 2087 points Heating: 2326 points Hot Water: 7380 points Hot Water: 7380 points Total: 18189 points Total: 17950 points PASS e-Ratio: 0.99 EnergyGauge®(Version". FLRCSB v4.0) 12/1/2005 3:53 PM FROM: Fax Southern Energy Eval Srvcs TO: 1-407-578-0471 PAGE: 001 OF 006 FORM 60OA-2004 EnergyGauge@ 4.0 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: West 16th Street, Sanford, FI, PERMIT#: BASE AS -BUILT GLASS TYPES 18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points 18 1048.0 25.78 4863.1 Double, Clear N 2.0 4.0 17.0 26.25 0.81 363.4 Double, Clear E 2.0 6.0 33.6 55.69 0.84 1575.9 Double, Clear E 2.0 5.0 14.2 55.69 0.76 603.0 Double, Clear E 2.0 4.0 8.5 55.69 0.69 328.1 Double, Clear S 2.0 5.0 11.2 41.92 0.71 335.5 Double, Clear S 8.0 5.0 27.6 41.92 0.50 583.1 Single, Clear W 2.0 6.0 6.0 57.68 0.84 291.1 Double, Clear W 2.0 6.0 16.8 50.22 0.84 709.8 Double, Clear W 2.0 5.0 8.5 5022 0.76 325.9 Double, Clear W 2.0 4.0 8.5 50.22 0.70 297.6 As -Built Total: 151.9 5413.5 WALL TYPES Area X BSPM Points Type R-Value Area X SPM Points Adjacent 0.0 0.00 0.0 Frame, Wood, Exterior 11.0 901.6 1.90 1713.0 Exterior 901.6 1.90 1713.0 Base Total: 901.6 1713.0 As -Built Total: 901.6 1713.0 DOOR TYPES Area X BSPM Points Type Area X SPM Points Adjacent 0.0 0.00 0.0 Exterior Wood 49.0 7.20 352.8 Exterior 49.0 4.80 235.2 Base Total: 49.0 235.2 As -Built Total: 49.0 352.8 CEILING TYPES Area X BSPM Points Type R-Value Area X SPM X SCM = Points Under Attic 1048.3 2.13 2232.9 Under Attic 19.0 1048.3 2.82 X 1.00 2956.2 Base Total: 1048.3 2232.9 As -Built Total: 1048.3 2956.2 FLOOR TYPES Area X BSPM Points Type R-Value Area X SPM Points Slab 0.0(p) 0.0 0.0 Raised Wood, Post or Pier 11.0 1048.3 1.83 1913.1 Raised 1048.3 3.43 3595.7 Base Total: 3595.7 As -Built Total: 1048.3 1913.1 INFILTRATION Area X BSPM Points Area X SPM Points 1048.0 14.31 14996.9 1048.0 14.31 14996.9 EnergyGauge® DCA Form 60OA-2004 EnergyGauge®/FlaRES'2004 FLRCSB v4.0 12/1/2005 3:53 PM FROM: Fax Southern Energy Eval Srvcs TO: 1-407-578-0471 PAGE: 002 OF 006 FORM 60OA-2004 EnergyGauge® 4.0 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: West 16th Street, Sanford, FI, PERMIT#: BASE AS -BUILT Summer Base Points: 20445.5 Summer As -Built Points: 27345.6 Total Summer X System Cooling Total X Cap X Duct X System X Credit Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points System - Points) DM x DSM x AHU) sys 1: Central Unit 24000 btuh ,SEER/EFF(12.0) Ducts:Unc(S),Ccn(R),Int(AH),R6.0(INS) 27346 1.00 1.08 x 1.150 x 0.90) 0.284 0.950 8244.1 20445.5 0.4266 8722.0 27345.6 1.00 1.117 0.284 0.960 8244.1 EnergyGaugeT° DCA Form 60OA-2004 EnergyGauge®/FIaRES'2004 FLRCSB v4.0 12/1/2005 3:53 PM FROM: Fax Southern Energy Eval Srvc3 TO: 1-407-578-0471 PAGE: 003 OF 006 FORM 60OA-2004 EnergyGauge@ 4.0 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: West 16th Street, Sanford, FI, PERMIT#: BASE AS -BUILT GLASS TYPES 18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Point 18 1048.0 5.86 1105.4 Double, Clear N 2.0 4.0 17.0 11.00 0.99 185.6 Double, Clear E 2.0 6.0 33.6 8.82 1.03 306.3 Double, Clear E 2.0 5.0 14.2 8.82 1.05 132.0 Double, Clear E 2.0 4.0 8.5 8.82 1.08 80.7 Double, Clear S 2.0 5.0 11.2 6.74 1.25 94.5 Double, Clear S 8.0 5.0 27.6 6.74 2.19 407.3 Single, Clear W 2.0 6.0 6.0 13.25 1.02 81.4 Double, Clear W 2.0 6.0 16.8 9.55 1.02 164.2 Double, Clear W 2.0 5.0 8.5 9.55 1.04 84.3 Double, Clear W 2.0 4.0 8.5 9.55 1.05 85.4 As -Built Total: 151.9 1621.5 WALL TYPES Area X BWPM Points Type R-Value Area X WPM Points Adjacent 0.0 0.00 0.0 Frame, Wood, Exterior 11.0 901.6 2.00 1803.2 Exterior 901.6 2.00 1803.2 Base Total: 901.E 1803.2 As -Built Total: 901.6 1803.2 DOOR TYPES Area X BWPM Points Type Area X WPM Points Adjacent 0.0 0.00 0.0 Exterior Wood 49.0 7.60 372.4 Exterior 49.0 5.10 249.9 Base Total: 49.0 249.9 As-Bullt Total: 49.0 372.4 CEILING TYPESArea X BWPM Points Type R-Value Area X WPM X WCM Points Under Attic 1048.3 0.64 670.9 Under Attic 19.0 1048.3 0.87 X 1.00 912.0 Base Total: 1048.3 670.9 As -Built Total: 1048.3 912.0 FLOOR TYPES Area X BWPM Points Type R-Value Area X WPM Points Slab 0.0(p) 0.0 0.0 Raised Wood, Post or Pier 11.0 1048.3 0.47 493.7 Raised 1048.3 0.20 209.7 Base Total: 209.7 As -Built Total: 1048.3 493.7 INFILTRATION Area X BWPM Points Area X WPM Points 1048.0 0 28 293.4 1048.0 -0 28 293.4 EnergyGauge® DCA Form 60OA-2004 EnergyGauge®/FlaRES'2004 FLRCSB v4.0 12/1/2005 3:53 ?M FROM: Fax Southern Energy Eval Srvca TO: 1-407-578-0471 PAGE: 004 OF 006 FORM 60OA-2004 EnergyGauge@ 4.0 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: West 16th Street, Sanford, FI, PERMIT #: BASE AS -BUILT Winter Base Points: 3326.3 Winter As -Built Points: 4909.5 Total Winter X System = Heating Total X Cap X Duct X System X Credit Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points System - Points) DM x DSM x AHU) Sys 1: Electric Heat Pump 22000 btuh ,EFF(7.8) Ducts: Unc(S),Con(R),Int(AH),R6.0 4909.5 1.000 1.068 x 1.160 x 0.92) 0.438 0.950 2326.0 3326.3 0.6274 2086.9 4909.6 1.00 1.140 0.438 0.960 2326.0 EnergyGaugeT" DCA Form 60OA-2004 EnergyGauge®/FlaRES'2004 FLRCSB v4.0 12/1/2005 3:53 PM FROM: Fax Southern Energy Eval Srvcs TO: 1-407-578-0471 PAGE: 005 OF 006 FORM 60OA-2004 EnergyGauge® 4.0 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS: West 16th Street, Sanford, FI, PERMIT #: BASE AS -BUILT WATER HEATING Number of X Multiplier Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 3 2460.00 7380.0 40.0 0.92 3 1.00 2460.00 1.00 73800 As -Built Total: 7380.0 CODE COMPLIANCE STATUS BASE AS -BUILT Cooling + Heating + Points Points Hot Water Points Total Points Cooling Points Heating + Hot Water = Total Points Points Points 8722 2087 7380 18189 82" 2326 7380 17950 PASS EnergyGaugeT" DCA Form 600A-2004 EnergyGauge®/FlaRES'2004 FLRCSB v4.0 12/1/2005 3:53 PM FROM: Fax Southern Energy Eval Srvca TO: 1-407-578-0471 PAGE: 006 OF 006 FORM 60OA-2004 EnergyGauge® 4.0 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: West 16th Street, Sanford, FI, PERMIT #: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/sq.fl. window area; .5 cfm/sq.ft. door area. Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from, and is sealed to, the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of lop floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous Infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from conditioned space, tested. Multi -story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration regts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. bA-ZZ U 1 MtK rKt5GKIr I IVt IVItA5UKt5 (must be met or exceeded DV all resluences. COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 612.1.ABC.3.2. Switch or clearly marked circuit breaker (electric) or cutoff (gas) must be provided. External or built-in heat trap required. Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls 607.1 Separate ready accessible manual or automatic thermostat for each system. Insulation 604.1. 602.1 Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. EnergyGaugeT" DCA Form 60OA-2004 EnergyGauge®/FlaRES'2004 FLRCSB v4.0 12/1/2005 3:57 PM FROM: Fax Southern Energy Eval Srvc3 TO: 1-407-578-0471 PAGE: 001 OF 001 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 83.8 The higher the score, the more eiFcient the home. Smith, West 16th Street, Sanford, FI, l . New construction or existing New - 2. Single family or multi -family Single family 3. Number of units, if multi -family I - 4. Number of Bedrooms 3 - 5. Is this a worst case? No _ 6. Conditioned floor area (ft2) 1048 ftz 7. Glass typeI and area: (Label reqd. by 13-104.4.5 if not default) a. U-factor: Description Area or Single or Double DEFAULT) 7a.(Dble Default) 145.9 fP _ b. SHGC: or Clear or Tint DEFAULT) 7b. Clear) 151.9 W _ 8. Floor types a. Raised Wood, Post or Pier R=11.0, 1048.3ft2 b. N/A c. N/A 9. Wall types a. Frame, Wood, Exterior R=11.0, 901.6 ft- _ b. N/A c. N/A d. N/A e. N/A 10. Ceiling types a. Under Attic R=19.0, 1048.3 ft' - b. N/A c. N/A 11. Ducts a. Sup: Unc. Ret: Con. AH: Interior Sup. R=6.0, 40.0 ft - b. N/A 12. Cooling systems a. Central Unit b. N/A c. N/A 13. Heating systems a. Electric Heat Pump b. N/A c. N/A 14. Hot water systems a. Electric Resistance b. N/A c. Conservation credits HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HVAC credits CF-Ceiling fan, CV -Cross ventilation, HF-Whole house fan, PT -Programmable Thermostat, NIZ-C-Multizone cooling, A17_-H-Multvone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code om li t features. / / 0SBuilderSignature: ) ItlA.1/M4 7 Date: IZ $ Address of New Home: VJ tb 'tt" -_ City/FL Zip. $,Uj Ft,2p. L - Cap: 24.0 kBtu/hr - SEER:12.00 - Cap: 22.0 kBtu/hr _ HSPF: 7.80 Cap: 40.0 gallons _ EF: 0 92 _ NOTE: The home's estimated energy performance score is only available through the FLARES computer program. This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a US EPAMOE EnergyStar7"designation), your home may qualify for energy efficiency mortgage (EEM) incentives ifyou obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 3211638-1492 or see the Energy Gauge web site at www.fsec. ucf edu for information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 8501487-1824. 1 Predominant glass type. For actual glass type and areas scc Summer & Winter Glass out ut on a es 2&4 nergyGaugeO (Version: ?LRCg) v4.0) PT' - 12/1/2005 3:58 ?M FROM: Fax Southern Energy Eval Srvcz TO: 1-407-578-0471 PAGE: 001 OF 006 J-MASTER(c) * 12-01-2005 RESIDENTIAL HEAT GAIN / HEAT LOSS CALCULATION BASED ON A.C.C.A. MANUAL J - EIGHTH EDITION'(c) 2003 by A.C.C.A.) Project name New residence Prepaired by: Address West 16th Street Southern Energy Eval Ser City/State Sanford 122 East Minnesota Ave. Owner Smith Orange City, Fl 32763 Builder Jim Walter Homes 1-800-329-SEES (7337) HVAC contr. FAX:1-800-639-SEES(7337) Cond Flr Area = 1048 JTotal Glass Area = 151.9 1 Zone Faces: South Conditioned Floor Area to Total Glass Area Ratio = 14.5% USA Climatic Conditions & Design Conditions Geographical Location Sanford, Florida North Latitude / Elevation 28 Deg. 14 Ft.Above Sea Level Outdoor Winter Dry Bulb 38 Deg.F Indoor Winter Dry Bulb 74 Deg.F Winter Temp. Diff. (wTd) 36 Deg.F Outdoor Summer Dry Bulb 93 Deg.F Outdoor Sumer Wet Bulb 76 Deg.F Outdoor Summer Hum. Ratio Gr/Lb 37 Indoor Summer Relaltive Hum. 50 Indoor Sumner Design Gr/Lb. 44 Indoor Sumner Dry Bulb 75 Deg.F Summer Temp.Diff.(sTd) 18 Deg.F Summer Daily Range 17 Deg.F (Medium Deviation) HEATING SUMMARY * SANANT_C.MAX * COOLING SUMMARY * SUBTOTAL = 17778.59 STRUCTURE SENSIBLE = 11879.31 OCCUPANT/APPLIANCE + 3690.00 SUBTOTAL SENSIBLE = 15569.31 DUCT LOSS + 888.94 DUCT GAIN + 1556.93 TOTAL LOSS = 18667.53 TOTAL SENSIBLE = 17126.24 MECH.VENT- 75 Cfm + 2970.00 MECH.VENT- 75 Cfm + 1485.00 TEMP.SWING @ 3m/95o x 1.00 EQUIPMENT LOSS = 21637.53 1 EQUIPMENT SENSIBLE = 18611.24 TOTAL LATENT + 4723.66 SENSIBLE + LATENT = 23334.90 2096 OVERSIZE FACTOR + 4327.51 20% SENS.OVRSZE FTR = 3722.25 ACTUAL+20% OVERSIZE = 25965.04 SENS. + 20% OVERSIZE = 22333.49 EQUIPMENT SELECTION * EQT. MANUF_. SENSIBLE CL (BTUH) CU MOD # _ LATENT CLG _ (STUN) AHU MOD # _ TOTAL CLG _24000 (BTUH) HTG INPUT (BTUH) TONAGE _ 2 HTG OUTPUT 22200 (BTUH) (S)EER 12.0 HTG CFM 800 CLG CFM 800 AFUE/HSPF 7.8 TYPE HP AIR FLOW FACTORS * HTG FACTOR = .0370653 BTUH per CFM CLG FACTOR = .0429848 BTUH per CFM STRUCTURE DESIGN CFM-- 957.4 SENSIBLE HEAT RATIO = 8% 12/1/2005 3:58 PM FROM: Fax Southern Energy Eval Scvc3 TO: 1-407-578-0471 PAGE: 002 OF 006 Calculation Procedures A,B,C,D I I Procedure A Winter Infiltration HTM I I 1. Winter Infiltration CFM Envelope Evaluation # 3 Better) 7 Air Changes per hour x 8384 Cubic ft. x .0167 98.01 CFM I 2. Winter Infiltration Btuh I 1.1 x 98.01 CFM x 36 Degrees Winter TD 3881.15 Btuh I 3. Winter Infiltration HTM I 3881.15 I Btuh / 200.9 Sq.Ft of total Glass & Door areas 19.32 HTM I I I Procedure B Summer Infiltration HTM I 1. Summer Infiltration CFM Envelope Evaluation # 3 ( Better) 35 Air Changes per hour x 8384 Cubic ft. x .0167 = 49.00 CFM I I 2. Summer Infiltration Btuh I 1.1 x 49 CFM x 18 Degrees Summer TD = 970.29 Btuh I I I 13. Summer Infiltration HTM 970.29 Btuh / 200.9 Sq.Ft. of total Glass & Door areas = 4.83 HTM I I I I I Procedure C Latent Infiltration Gain I 0.68 x 44 grains difference @ 50% RH x 49 CFM = 1466.08 Btuh I I I Procedure D Equipment Sizing I I 1. Sensible Sizing Loads I I Sensible Ventilation Load I 1.1 x 75 Vent CFM x 18 Degree Summer TD 1485.00 Btuh I Sensible Load for Structure 11879.31 Btuh Sum of Ventilation & Structure Loads 13364.31 Btuh I Rating & Temperature Swing Multiplier x 1.00 RSM Equipment Sizing Load - Sensible 13364.31 Btuh I 2. Latent Sizing Load I I Latent Ventilation Load I 0.68 x 75 Vent CFM x 44 Grains difference 2244.00 Btuh Internal Loads = 230 Btuh x 6 people 1380.00 Btuh Infiltration Load from Procedure C 1466.08 Btuh Equipment Sizing Load - Latent I 5090.08 Btuh I 12/1/2005 3:58 ?M FROM: Fax Southern Energy Eval Srvcs TO: 1-407-578-0471 PAGE: 003 OF 006 I I S.C.= Single I D.C.= Double T.C.= Triple Shdg= Shading Sc = Shading I N.S.= No I IWhtm = Winter Abbreveations Glass/Windows Clear S.T. = Single Tint S.R. Clear D.T. = Double Tint D.R. Clear T.T. = Triple Tint T.R. Ovhg = Overhang ; Btm = Bottom Coefficient Inside Shading * shades D/B = Drapes or Blinds; Other Heat Transfer Multiplier; IInfiltration #Is: 1..Sub I Standard/Poor; I I Single Reflective I Double Reflective I Triple Reflective I Hgt = Height I I I R.S. = Roller Shades I I Shtm = Summer Heat Transfer Multiplierl 2..Standard; 3..Better; 4..Excellent I I I 1 RooName Dining Room Square Footage IRoomIRm 106.70 I m I1IRooDeminsion : 10.67x10 I I I IGlass Type Shdg OvHg Botm Hgt Sc Area Loss/Btuh Gain/Btuh I I------------------------------------------------------------------------------I IS -All Shaded D.C. R.S. 2.0 5.0 4.2 1.0 11.20 262.08 215.04 I I------------------------------------------------------------------------------I IW-Shaded Area D.C. R.S. 2.0 4.0 3.0 1.0 1.87 35.90 I IW-Solar Area D.C. R.S. 6.63 385.87 I IW-T. Area Loss D.C. R.S. 8.50 198.90 I I Comiponet Description I R- value Area Loss Gain I IWood Stud- Ext. 11 177.66 575.62 344.66 I ISolid Core/ Wood-Ext. 0 13.00 149.76 63.70 I Under Attic 19 106.70 202.17 235.77 I IRsd Wood - Post or Pier-Ext. it 106.70 614.59 85.36 I IGlass/Door Infil. Whtm/14.49 Shtm/3.62 x 32.7 473.82 118.37 I Occupant Gain 000.00 900.00 i IDuct Loss/ Gain 123.85 238.47ms I ITotalRoom Loss/Gain 2600.79 2623.14 I Interpolated CFM = 105.33 I ISupply Htg/ Clg CFM = 96.40 112.80 I I I 1 RooName Living Room Square Footage IRoomIRm 164.70 IRoom12I RoaDeminsion12x12.17/5.33x3.5 I I I IGlass Type Shdg OvHg Botm Hgt Sc Area Loss/Btuh Gain/Btuh I I------------------------------------------------------------------------------I IS -All Shaded D. C. R.S. 8.0 5.0 4.2 1.0 27.60 645.84 529.92 I IE-Shaded Area D. C. R.S. 2.0 5.0 4.0 1.0 2.34 44.93 I IE-Solar Area D. C. R.S. 11.86 690.25 I IE-T.Area Loss D.C. R.S. 14.20 332.28 I I------------------------------------------------------------------------------I Componet Description I R- value Area Loss Gain I IWood Stud-Ext. it 130.56 423.01 253.29 I ISolid Core/Wood-Ext. 0 21.00 241.92 102.90 I Under Attic 19 164. 70 312.06 363.93 I IRsd Wood - Post or Pier-Ext. 11 164.70 948.67 131.76 I 12/1/2005 3:58 ?M FROM: Fax Southern Energy Eval Srvco TO: 1-407-578-0471 PAGE: 004 OF 006 Glass/Door Infil. Whtm/14.49 Shtm/3.62 x 62.8 909.97 227.34 1 Occupant Gain 000.00 900.00 I Appliance Gain 000.00 230.00 I Duct Loss/Gain 190.69 347.43 I ITotal Room Loss/Gain 4004.44 3821.75 I Interpolated CFM = 156.98 I ISupply Htg/Clg CFM = 148.40 164.30 I I I IRm #1 Room Name Kitchen Room Square Footage I 93.50 I 13 I Roan Deminsion : llx8.5 I I I Glass Type Shdg OvHg Botm Hgt Sc Area Loss/Btuh Gain/Btuh I I------------------------------------------------------------------------------I IW-Shaded Area D.C. R.S. 2.0 5.0 4.0 1.0 1.40 26.88 I IW-Solar Area D.C. R.S. 7.10 413.22 I IW-T.Area Loss D.C. R.S. 8.50 198.90 I I Ccmponet Description I R-value Area Loss Gain I Wood Stud-Ext. 11 79.50 257.58 154.23 Under Attic 19 93.50 177.16 206.60 1 IRsd Wood - Post or Pier-Ext. 11 93.50 538.56 74.80 1 Glass/Door Infil. Whtm/14.49 Shtm/3.62 x 8.5 123.17 30.77 1 Appliance Gain 000.00 1290.00 1 Duct Loss/Gain 64.77 219.65 1 ITotal Roan Loss/Gain 1360.14 2416.15 1 Interpolated CFM = 92.58 1 ISupply Htg/Clg CFM = 50.40 103.90 I 1 I - IRm #1 Roam Name Br 3 Room Square Footage I 161.50 I 1 4 1 Room Deminsion : 10.42xl2/3.5x10.42 1 I I Glass Type Shdg OvHg Botm Hgt Sc Area Loss/Btuh Gain/Btuh I I------------------------------------------------------------------------------I IE-Shaded Area D.C. R.S. 2.0 6.0 5.0 1.0 2.22 42.62 I IE-Solar Area D.C. R.S. 14.58 848.56 I IE-T.Area Loss D.C. R.S. I 16.80 393.12 I I Componet Description I R-value Area Loss Gain I Wood Stud-Ext. 11 66.56 215.65 129.13 1 Under Attic 19 161.50 306.00 356.86 1 IRsd Wood - Post or Pier-Ext. 11 161.50 930.24 129.20 1 1Glass/Door Infil. Whtm/14.49 Shtm/3.62 x 16.8 243.43 60.82 1 Duct Loss/Gain 104.42 156.72 1 ITotal Room Loss/Gain 2192.86 1723.91 I 11nterpolated CFM = 78.01 1 ISupply Htg/Clg CFM = 81.30 74.10 I 1 I I IRm #1 Rocca Name Util/Laundry Room Square Footage 51.80 I 15 1 Room Deminsion : 6.1x8.5 I I 1 1Glass Type Shdg OvHg Botm Hgt Sc Area Loss/Btuh Gain/Btuh 1 I------------------------------------------------------------------------------1 12/1/2005 3:58 PM FROM: Fax Southern Energy Eval Srvc3 TO: 1-407-578-0471 PAGE: 005 OF 006 IW-Shaded Area S.C. R.S. 2.0 6.0 5.0 1.0 79 18.49 I IW-Solar Area S.C. R.S. 5.21 345.94 I IW-T.Area Loss S.C. R.S. I 6.00 249.48 I Componet Description I R-value Area Loss Gain I Wood Stud-Ext. it 27.80 90.07 53.93 I Solid Core/Wood-Ext. 0 15.00 172.80 73.50 I Under Attic 19 51.80 98.15 114.46 I IRsd Wood - Post or Pier-Ext. 11 51.80 298.37 41.44 I Glass/Door Infil. Whtm/14.49 Shtm/3.62 x 21 304.29 76.02 I Appliance Gain 000.00 370.00 I Duct Loss/Gain 60.66 109.38 I ITotal Rocca Loss/Gain 1273.82 1203.16 I Ilnterpolated CFM = 49.65 1 ISupply Htg/Clg CFM = 47.20 51.70 I 1 I IRm #1 Room Name Bath 1 Room Square Footage I 41.30 I 16 I Room Deminsion : 5.5x7.5 I I I Glass Type Shdg OvHg Botm Hgt Sc Area Loss/Btuh Gain/Btuh I I------------------------------------------------------------------------------I IE-Shaded Area D.C. R.S. 2.0 4.0 3.0 1.0 1.87 35.90 I IE-Solar Area D.C. R.S. 6.63 305.87 I IE-T.Area Loss D.C. R.S. 8.50 198.90 I I------------------------------------------------------------------------------I I Componet Description R-value Area Loss Gain I I------------------------------------------------------------------------------I Wood Stud-Ext. 11 35.50 115.02 68.87 I Under Attic 19 41.30 78.25 91.26 I IRsd Wood - Post or Pier-Ext. 11 41.30 237.89 33.04 I IGlass/Door Infil. Whtm/14.49 Shtm/3.62 x 8.5 123.17 30.77 I IDuct Loss/Gain 37.66 64.57 I ITotal Room Loss/Gain 790.89 710.28 I Interpolated CFM = 29.9 1 ISupply Htg/Clg CFM = 29.30 30.50 I 1 I IRm #1 Room Name Closet Room Square Footage I 24.80 I 17 I Room Deminsion : 4.5x5.5 I I I I01ass Type Shdg OvHg Botm Hgt Sc Area Loss/Btuh Gain/Btuh I I------------------------------------------------------------------------------I I Coonponet Description I R-value Area Loss Gain I Under Attic 19 24.80 46.99 54.80 I IRsd Wood - Post or Pier-Ext. 11 24.80 142.85 19.84 I Duct Loss/Gain 9.49 7.46 I ITotal Room Loss/Gain 199.33 82.10 I Ilnterpolated CFM = 6.65 1 ISupply Htg/Clg CFM = 7.40 3.50 I 1 I IRm #1 Room Name Br 1 Room Square Footage 168.00 1 8 I Room Deminsion : 12x14 I 12/l/2005 3:58 ?M FROM: Fax Southern Energy Eval Srvcs TO: 1-407-578-0471 PAGE: 006 OF 006 IGlass Type Shdg OvHg Botm Hgt Sc Area Loss/Btuh Gain/Btuh IE-Shaded Area D.C. R.S. 2.0 6.0 5.0 1.0 2.22 42.62 I IE-Solar Area D.C. R.S. 14.58 848.56 I IE-T.Area Loss D.C. R.S. 16.80 393.12 I I------------------------------------------------------------------------------I IN -No Shd Fctr D.C. R.S. 2.0 I 4.0 n/a 1.0 8.50 198.90 163.20 I Componet Description I R-value Area Loss Gain I Wood Stud-Ext. 11 182.70 591.95 354.44 I Under Attic 19 168.00 318.32 371.22 I IRsd Wood - Post or Pier-Ext. it 168.00 967.68 134.40 I Glass/Door Infil. Whtm/14.49 Shtm/3.62 x 25.3 366.60 91.59 I IDuct Loss/Gain 141.83 200.60 I ITotal Roam Loss/Gain 2978.40 2206.63 I Interpolated CFM = 103.37 1 ISupply Htg/Clg CFM = 110.40 94.90 I 1 I I Rm # 1 Rooma Name Br 2 Roams Square Footage I 130.00 I 1 9 1 Room Deminsion : 10.83xl2 I I I IGlass Type Shdg OvHg Botm Hgt Sc Area Loss/Btuh Gain/Btuh I I------------------------------------------------------------------------------I IN -No Shd Fctr D.C. R.S. 2.0 4.0 n/a 1.0 8.50 198.90 163.20 I I------------------------------------------------------------------------------I IW-Shaded Area D.C. R.S. 2.0 6.0 5.0 1.0 2.22 42.62 I IW-Solar Area D.C. R.S. 14.58 848.56 I IW-T.Area Loss D.C. R.S. I 16.80 393.12 I Camsponet Description I R-value Area Loss Gain I Wood Stud-Ext. 11 157.34 509.78 305.24 I Under Attic 19 130.00 246.32 287.26 I IRsd Wood - Post or Pier-Ext. it 130.00 748.80 104.00 I IGlass/Door Infil. Whtm/14.49 Shtm/3.62 x 25.3 366.60 91.59 I IDuct Loss/Gain 123.18 184.25 I ITotal Room Loss/Gain 2586.70 2026.72 I Interpolated CFM = 91.87 1 ISupply Htg/Clg CFM = 95.90 87.10 I 1 I I Rm # 1 Roams Name Bath 2 Rooms Square Footage I 66.00 I 1 10 I Rooms Deminsion : 5.5xl2 I I I IGlass Type Shdg OvHg Botm Hgt Sc Area Loss/Btuh Gain/Btuh I I------------------------------------------------------------------------------I I Componet Description R-value Area Loss Gain I I------------------------------------------------------------------------------I Wood Stud-Ext. 11 44.00 142.56 85.36 I Under Attic 19 66.00 125.05 145.84 I IRsd Wood - Post or Pier-Ext. 11 66.00 380.16 52.80 I IDuct Loss/Gain 32.39 28.40 I ITotal Roam Loss/Gain 680.16 312.40 I Interpolated CFM = 22.77 1 ISupply Htg/Clg CFM = 25.20 13.40 I 1 C0No R/A DUCT OVER SUPPLY DUCT. Jim Walter Homes San Antonio Model South Facing A.D.S. r JN OO OO Cn LAM N 1 Cl- 00 CV Ti Li1 OO N 1j:] . i 1 V IU4; e. L V.: IwoINNS wee. tee© 1. :1 M©:' wee I 1. COUNTY OF SEMINOLE IMPACT FEE STATEMENT ISSUED BY CITY OF SANFORD STATEMENT NUMBER 106-75008 P,qlo FM 2 8 2006 DATE: CITY CRD BUILDING PERMIT NUMBER:0kp-\0_)_, (CITY) COUNTY NUMBER: UNIT ADDRESS: \ ac7 \\o``^ 4 t TRAFFIC ZONE: JURISDICTION: 06 CITY OF SANFORD SEC: TWP: RNG: PARCEL: 3s-\S--2, - ti'L(-Ub-'L37-U SUBDIVISION: TRACT: PLAT BOOK: PLAT BOOK PAGE: BLOCK: LOT: OWNER NAME: ADDRESS: APPLICANT NA..... ADDRESS: LAND USE CATEGORY: 001 - Single Family Detached House TYPE USE: Residential WORK DESCRIPTION: Single Family House: Detached - Construction FEE BENEFIT RATE FEE UNIT RATE PER # & TYPE TOTAL DUE TYPE DIST SCHEDULE DESC. UNIT OF UNITS ROADS ARTERIALS CO -WIDE 0 dwl unit $ 705.00 1 $ 705.00 ROADS COLLECTORS NORTH 0 dwl unit $ 000.00 1 $ 000.00 LIBRARY CO -WIDE 0 dal unit SCHOOLS CO -WIDE 0 dwl unit STATEMENT RECEIVED BY: 11v PLEA E PRINT NAME) SIGNATUR 54.00 1,384.f0 1 AMOU DATE: 1 $ 54.00"" 1 t 1,384.00 2,143.00 NOTE TO RECEIVING SIGNATORY/APPLICANT: FAILURE TO NOTIFY OWNER AND ENSURE TIMELY PAYMENT MAY RESULT IN YOUR LIABILITY FOR THE FEE. **** DISTRIBUTION: 1-COUNTY 3-CITY 2-APPLICANT 4-COUNTY NOTE** PERSONS ARE ADVISED THAT THIS IS A STATEMENT OF FEES WHICH ARE DUE AND PAYABLE PRIOR TO ISSUANCE OF A BUILDING PERMIT. PERSONS ARE ALSO ADVISED THAT ANY RIGHTS OF THE APPLICANT, OR OWNER, TO APPEAL THE CALCULATIONS OF THE ROAD, LIBRARY SYSTEM AND/OR EDUCATIONAL (SCHOOL) IMPACT FEES MUST BE EXERCISED BY FILING A WRITTEN REQUEST WITHIN 45 CALENDAR DAYS OF THE RECEIVING SIGNATURE DATE ABOVE, BUT NOT LATER THAN CERTIFICATE OF OCCUPANCY OR OCCUPANCY. THE REQUEST FOR REVIEW MUST MEET THE REQUIREMENTS OF THE COUNTY LAND DEVELOPMENT CODE. COPIES OF THE RULES GOVERNING APPEALS MAY BE PICKED UP, OR REQUESTED, FROM THE PLAN IMPLEMENTATION OFFICE: 1101 EAST FIRST STREET, SANFORD, FLORIDA 32771; (407) 665-7474. PAYMENT SHOULD BE MADE TO: CITY OF SANFORD BUILDING DEPARTMENT 300 NORTH PARK AVENUE SANFORD. FL 32771 PAYMENT SHOULD BE BY CHECK OR MONEY ORDER, AND SHOULD REFERENCE THE STATEMENT NUMBER AND CITY BUILDING PERMIT NUMBER AT THE TOP LEFT OF THE NOTICE. THIS STATEMENT IS VALID ONLY IN CONJUNCTION WITH ISSUANCE OF A*** SINGLE FAMILY BUILDING PERMIT******************** 9 sup R LOT 23 _(8.9) 5' CLF CORNER IS 0.2 N. 0.6 W. 4' CLF CORNER IS REC 1" IP REC 1/2" IP 0.8 S. 0.2 W. 50.0 PLAT, 49.99 MEAS. ( 8.6) FF S 89-59-38 E t ( 10.0) 4' CLF CORNER IS B } [ 11.5] 0.5 S. 1.3 E. 11.51 R/W q R/W LOWEST POINT POINT MIN.9 R W-A 1.0 C-A 1.0 O-C 2.0 D-FF MIN. 0.67' A-R 1.0 LOT GRADING PLAN TYPE (A) r0 m 10.4) f O VI rn rm m D0 I nOA ZM II M oZ 63m 9 r D LnO CI m DN O __l II j--15.8 I+ O N REC 1" IP ® THE SE CORNER OF LOT 40 FENCE CORNER IS 1.5 EAST CALCULATED CORNER 100.0 PLAT V 99.54 MEAS. -j 3.7 9.78) J 0.5' CONCRETE CURB SET PK + DISK GENERAL NOTES` I. !,ALL SURVEY INFORMA71ON (I.E. EXISTING TOPOGRAPHIC SHOTS, BOUNDARY, & LOCATION) WAS PROVIDED BY PA TRICK K. VANDERIMEN, PLS LAND SURVEYING SERVICES, 6419 VINELAND ROAD, ORLANDO, FL 32819 AND RELIED ON FOR LOT GRADING DESIGN. Z ALL ELEVATIONS SHOWN ARE BASED ON SEMINOLE COUNTY ASSUMED DATUM. SITE BENCHMARK (78M) EAST END OF THE 0.5- CONCRETE CURB AS BEING ELEV. I0.00 (BASED ON ASSUMED DATUM) ALL ELEVA170N5 SHOULD BE VERIFIED BY PA7RICK K. VANDERWYDEN, PLS. 3. BEARINGS ARE BASED UPON THE NORTH RAV OF 16th STREET AS BEING N 90-00-00 E ( AN ASSUMED BEARING ) 4. THIS DRAWING IS FOR LOT GRADING ONLY. ALL OTHER SURVEY INFORMA77ON SHOULD BE OBTAINED FROM J7M WAL TER HOMES 9.1)_\ r0 11.3 E^' 24.0 N O p MIN. FLR. 12.20 9.5) J 10.0 PORCH Y/ U K m D 8.1)JI cn 36.0 (\ WI 10.0] [10.0 (10.4) 4' CLF ENDS 0.8 NORTH 5' CONCRETE SIDEWALK /_TBM (10.00) 8.7) P rn 'n D D 0 rrnOZA u0n vm A z m 8.7) LEI LLJ L O V Lil J Q U 1n af O Z REC LB 220 3/4" IR SE CORNER OF LOT 35 CALCULATED CORNER 4' CLF ENDS 0.6 EAST 100.0 PLAT q 99.54 MEAS.. l \ 16th STREET ASPHALT PAVEMENT I 1". I\ N 90-00-00 E 50.0 PLAT, 49.78 MEAS. C/L ni/ 40' R/W\ CROWN OF ROAD (997)J SET PK + DISK LEGAL DESCRIPTION: LOT 37, FLORIDA LAND AND COLONIZATION COMPANY'S ADDITION TO SOUTH SANFORD, ACCORDING TO THE PLAT THEREOF AS RECORDED IN PLAT BOOK 1, PAGE 73, PUBLIC RECORDS OF SEMINOLE COUNTY, FLORIDA. LEaw 10.0 PROPOSED GRADE ELEVATIOW (BASED ON IBM) 10.0) EXIST. SPOT GRADE ELEVA71ON (BASED ON IBM) PROPOSED SWALE OR FLOW DIREC770VV ZEV COHEN BERNETTE SMITH X'V'& ASSOCIATES, INC $00' 55 Seton Trail, Ormond Beoch, Florido, 32176 05131105 ( 386) 677-2482 FAX 677-2505 SLOTGRADINGPLAN99064ENGINEERPLANNERS LANDSCAPE ARCHITECTS ta . nc cz) DOD) R:/99064/8-SMITH.DWC (g) COPYRIGHT BY Z£V COHEN A': ASSOCIATES INC. 2005 Aug 15 200E 2:41PM HP LRSERJET FRX p.2 MY OF SANFORD PERMIT APPLICATION roil N: 0.9 3 Date: b Address: 12 2 O W • 1 6' t S /'N e`%- eseripKioaof Work: /er L`j— _ --Total Square Foutal;e ---- o :J isteric District.._--_ Zoning: _T Value of Work: S__Cj wait Type: Building. - ___• Eloxtrical X_- Mechanic al _—__ Plumbing Fire SpnnkicieAla ni ("Col eetricai New Senior ll of ANIPS 2 0 O AdditioNAltcfalion _ Changc of Service _ Tcmlw)rary Pole. 60 R eehanieal: RcsidentW . _— Non-Residcutial Rep6ccment _— Nav (Duct La.•uut & En:rgy C.&Ic. Required) umbiag/ New Ceintmercial: # of Fixicim ornbingiNew Residen". N of Water Closers of Water & Scwer Lirxs_— $ of Gas Lines eupaaey Type: Residential _-- Commerdal _-- InduAttal Plumbing Repair - Restdent A or Commercial tnatruetioo Type: N of Storks: # of Dtvelliog Limits: Flood Zuate. (FENIA forth required t vam Name & Address: @ r ti ?7Q 7- Phone: 9 =_'Y 3324-`' atracmr Name ec Address: i n P F /G CTr` ; C —Q f:y o o /le o r/,_•R c. /( jJ ci h e F1-Y y ? tare Number: -'r a o 2 i 9 S% Coataet Person:/ f * 1 ^4X C1 v_ Phorte• 71 Z lasting CompaaY Su ^ev h C. t, --- --- Id., aa:-7& n7 YO- . 3 3 6'a tdr•ess: — —_ - -- — -- -- -.—... -- -- -- -- -- ehitesUEngi¢eer. -.-. . --- . - _ - . -- _ dress: attune Fs plicadon is hrreby made Do obtain o pcnstit to do the wort and imtallmiruks as indicated 1 comfy dwno work-oc4n:stailat, on Ika_s awomeru:ed prior to the uenee of a permit art! dug all trotk will be pe iormed to meeit standards of aY isys regulating eonstnictiort in this )ouisdicu m. I undetsurrtd that a separate mit rtu , be soa=od for ELECTRICAL WORK PLUMBING. SKAJS. WELLS. POOLS. FURNACES. BOILERS. HEA"ERS. TANKS. and R CONDITIOIwos, etc. VNER' S AFFIDAVIT: I certify dot all of Use foregoiog inft>tmatiott is aeearaw and that ail work Nitl be done to cornplian x with alI Wokabic taws rcbtdating tsbuotion and saiaiag WARNLNG TOOWNF3t: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT M YOUR PAYING VICE FOR tMPROVEMEN TS TO YOUR PROPERTY. IF YOU MEND TO OBTAIN FINANCV4G, CONSULT WITH YOUR LENDER OR AN TORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. M: In addWX to 111C tnt;rtitCtneoO of this PaIrtit. dMIX may be additional restrictions applicable to this prop" that n ay be found to the public rev"ds of cowtty. and thtra ratty be additinal paeans reQuaW Croat Odra govtruvttatal cuides such as water rmanagetmatt Jistrie s, state agencies. or federel agencks. cepfance of pemut is Verifautioo that 1 sill motif} the onrttcr of the Pr%—y of the rcgtt;remosnts f Ro ll Lies Law. f S ; 13. Sigrianae ofOwnu/ANent Date tgriat>Q< tit Contractor,Abent U Date PriatOwou! Agm's Name Print Costractor.Agetv's Nara P .................. RL "NIA F Sq ueofNotiryStateofFWda Datc l) weedALeat is _ PersorWly Koawa to Me.0 ProdoccdID PROVALS ZONING: cial Condidarts: IrYJ. 0016 OM Comm# DD0244125 t-. Notary - Sate of Florid, Expires 9272007 Bonded dins (&)0)432-425 n•'' Florida NotatY Assn.. ltiC Contractor/ Agent is oasonsUr inowa Menu Produced iD ENE:----•----•— BLDCi:-------- DEVELOPMXNT FgE WORKSHEET Utility Department Project Name: N4A-1 A00A -c— 'Date at- Owner/Contact.Person: v7f Phone: Address: 1 TYPE OF DEVELOPMENT: Residential ® Non -Residential El 2) TYPE OYUNIT(s): Single Family tz * Multi -Family Commercial, Industrial. 3) TOTAL NUMBER OF .UNITS or BUILDINGS: 4) TYPE OF UTILITY -CONNECTION: a) Meter: Individual Master Tap Required Tap Existing b Sewer Tap: Individual . Common b Tap Required Tap Existing 5) WATER METER SIZE: %-inch© 1-inch 1 '/z-inch 2-inch Supplied by Contractor 6) AWS METER:' NoneF] Individual Master Supplied by Alternative water supply) Meter Meter Contractor a) Meter Size: %-inch 1-inch 1 %Z-inch 2-inch Supplied by Contractor SUMMARY OF IMPACT FEES METER SET and TAP CHARGES Water impact fees........ $ // 93 COMMENTS: Sewer impact fees........ $ 2 L Ava ey/ Water Meter set .......... $ Water Meter set and tap $ y7 Meter deposit and S/C.. $ y C_Lr Sewer tap ................ $1 o o f 3S70'Lt AWS Meter Set .........$ AWS Meter Tap & Set..$ TOTAL DUE .......... $ Signature - Utility Director or Engineer Date: o Page 1 of 2 City of Sanford Utility Department Updated: July, 2005 g P.O. Box 1788, Sanford, Fl. 32772 Phone (407) 330-5641 P.O. Box 580937 Orlando, FL 32858 Phone: 407-721-2292 Fax: 407-905-9422 E-Mall. dbec@engineer.com March 21, 2007 Attn: Residential Building Department 12 WesstAMAS'tree* Sanford, Florida Pe it # 0610f73 Dear Building inspector; This letter is to inform you that I, Michael Thompson (PE47509), have conducted a roofing inspection at the above residential home. After having inspected the roofing structure, it is in my determination that the roof 30 pound felt underlayment dry -in application shows no evidence of poor workmanship and meet the current roofing codes as shown in the 2004/2006 Florida Building Code. Should you have any questions, please feel free to contact me at 407-721-2292. Thank you, Cctural ael Thompson, MS, PE Engineer