City of Sanford
Certificate of Occupancy
This is to certify that the building located at 212 W 20t' Street for which permit number
04-2405 was issued and has been completed according to the plans and specifications filed in
the permit, to wit a New Single Family Residence complies with all the building, plumbing,
electrical, mechanical, as well as City of Sanford codes and ordinances and with the provisions
of these regulations.
Staff Approval Date Conditions (if blank, no conditions apply)
Building:
R. Addison 03/15/05
Engineering:
D. Richards 03/23/05
Public Works:
J. Crumpton 03/17/05
Utilities:
R. Blake 03/18/05
Fire Department:
Zoning:
James Blagg YV1, _ 03/23/05
Property Owner Building Official Date
CERTIFCATE OF OCCUPANCY
REQUEST FOR FINAL INSPECTION
DATE:
PERMIT #:
ADDRESS:
CONTRACTOR:
PHONE #:
a
Single Family Residence****
1
5
3
03/17/05
04-2405
212W20"ST
James Blagg
407-302-9687
The building division has prepared a Certificate of Occupancy for the above
location and is requesting final inspection by your department. After your
inspection, please sign off and date the C. O. or submit addendum if it has
been denied or approved with conditions. Your prompt attention will be
appreciated.
Engineer'n 3 z o
Public Works
Utilities
Fire
lZoning
licensing
CONDITIONS: (TO BE COMPLETED ONLY IF APPROVAL IS CONDITIONAL)
CERTIFCATE OF OCCUPANCY
REQUEST FOR FINAL INSPECTION
DATE:
PERMIT #:
ADDRESS:
CONTRACTOR:
PHONE #:
Single Family Residence****
03/17/05
04-2405
212W20"ST
James Man
ter- 3a_
The building division has prepared a Certificate of Occupancy for the above
location and is requesting final inspection by your department. After your
inspection, please sign off and date the C. O. or submit addendum if it has
been denied or approved with conditions. Your prompt attention will be
appreciated.
Engineering Fire _
Pu ic Works,Zoning _
3.
0
Utilities licensing
CONDITIONS: (TO BE COMPLETED ONLY IF APPROVAL IS CONDITIONAL)
CERTIFCATE OF OCCUPANCY I
REQUEST FOR FINAL INSPECTIC!-N
LU
Single Family Residence**** LU
t- -
t I 1 1 1 1
DATE: 03/17/05
PERMIT #: 04-2405
ADDRESS: 212 W 20th ST
C w ti
CONTRACTOR: James Man
Z
o
PHONE #: 407-302-9687
V S
The building division has prepared a Certificate of Occupancy for the above
location and is requesting final inspection by your department. After your
inspection, please sign off and date the C. O. or submit addendum if it has
been denied or approved with conditions. Your prompt attention will be
appreciated.
Engineering
Public Works
Fire
TZoning
A'Utilities (Licensing
CONDITIONS: (TO BE COMPLETED ONLY IF APPROVAL IS CONDITIONAL)
LMBC1001 CITY OF SANFORD
i Address Misc. Information Inquiry
3/18/05
13:37:15
Location ID . . . . . . .
Parcel Number . . . . . .
Alternate location ID . .
Location address . . . . .
Primary related party . .
Type options, press Enter.
5 View detail
Opt Description
CUSTOMER SERVICE NOTES
CUSTOMER SERVICE NOTES
CUSTOMER SERVICE NOTES
CUSTOMER SERVICE NOTES
268655
36.19.30.506-0000-1420
212 W 20TH ST
Free -form information
SW DEV FEE $1700.00 WA DEV FEE $650.00
BP04-2405 PD 7-1-04 SEE REC#6998
3/4"WA METER SET FEE $190.00 PD 7-1-04
ST) $855.00 PD 7-1-04 REC#6998
F2=Address F3=Exit F5=Special Notes F9=Parcel Notes%
F12=Cancel
BOUNDARY SURVEY
FOR
JAMES A. BLAGG
DESCRIPTION: LOT 142, SANFORD HEIGHTS ADDITION, ACCORDING TO THE PLAT THEREOF AS
RECORDED IN PLAT BOOK 2, PAGES 62 AND 63 OF THE PUBLIC RECORDS OF
SEMINOLE COUNTY, FLORIDA.
REC. 1/2-1.R.
NON)
14' Alley, Per
Plat —Open, Dirt
Fence Corner /
2.2'S.dr 0.8'w.
Edge of Mel
Root 0 3'Eosl
lMellorRoo:
Overhang
O
IO
VN
49.8 I
3 '
143 0
Iu _ Q
u Q
0o _ Z
Fence Corrnn\er
4.3,w. 50 2
50.2—
I
116
53'P.
N 89 ' S3' 25" E 53. 1 2' M.
I
117
Wood Power Pole
1.0'5 k 0.2'w.
46.6 ,
Overhead Ut ililyLOT142)
Lines (Typ.)
REC. 5/8"I.R.(L.S.3764 )
Conc. Drive ALSO REC.1/2"I.R.(L.S.
3382) 0.50'E.
49 5
4'
16' 2.7' 4 9.2
49.8
21.44' 4 6. 4
rr—
7'
49.4
3 0
Conc.
Walk ~
n
3
Roofed ?'33'
Conc. o O
Porch O
9.65. 3.80' o
a'
a in
m
ro
o
u
a
ONE STORY o 3 14 1
C.B. RESIDENCE U v
v; F.F. Elev.=50.70
Q
Q
7.24 lJ
z
39.12' 7/
48.6 o49. —/
t9
5'
Roofed I -iW
Patio 3 2
o a
3
1 0.5' wide Yw
o u Wood Ret. a30Ic
U
Wall
3' I
50.6— Water Meter 49.0 211'
f -- --_ f—1
REC.1/2' R. N 89'54' 50" E 53. 30' M. REC. 5/8-I.R.(L.S.3764)
NON) 53'P. ALSO REC 1/2"I.R.(L.S..
3382) 0 46'E 0
N (
N212 W.)
N
SITE BENCHMARK ELEV.=49.82,7-'
CU -X" ON TOP OF CURB 2 0 T H. S T R E E T
4- i (PUBLIC R/W-OPEN,PAVED 48.58
NOTE:
THE ELEVATION AND LOT GRADING ON THE ABOVE REFERENCED
RESIDENCE MEETS OR EXCEEDS THE REOUIREMENTS AS OUTLINED
IN SANFORD CITY CODE SECTION 6.7 ABBREVIATIONS:
O
w
V T
SCALE
1' =30'
REC. DENOTES RECOVERED
I.R. IRON ROD
SURVEY REPORT: C CENTERLINE
R/W RIGHT-OF-WAY
1. This surve,Y does not reflect or determine ownership. C.B. CONCRETE BLOCK
2 Till,- data has not been furnished to this surveyor unless otherwise noted.
RES.
CONC
RESIDENCE
CONCRETE
3. Underground improvements or underground foundations hove not been located A•C. AIR CONDITIONER
except as noted on survey mop.
L.S. LICENSED SURVEYORL.B. LICENSED BUSINESS
4. Acc.)rding to the Federal Insurance Role Mop, this property lies in Zone "X",
Community -Panel number 120294 0045 E, Doted April 17, 1995.
5. This property lies Section 36, Township 19 S, Range 30 E.. Seminole County, Florida.
6. Site Benchmark and elevations are based on Seminole County vertical datum (NGVD '29).
HE;VR.TCH—L UKE &
SIVAGGERTY, LLC
surveyors & mappers
250 S. Ronald Reagan Blvd.
Suite 114
Longwood, FL 32750
407) 64 7- 734 6
Fox (407) 647-8097
Licensed BLIsiness No 7276
f
N
I
O
p
03/23/2005 14:57 4076478097 HENRICH PAGE 01
MULK41LC111ItKUL14:TMAKAL N&HiAutmv
NATIONAL FLOOD MMURANCE PROGRAM
ELEVATION CERTIFICATE
O. M. B. No. 3067-0077
Expires December 31, 2005
dokoft;dve on am 1-7.
SECTION A - PROPERTY OWNER INFORMATION 1 For- 11 w Carsarh tlw I
BUILDING STREET ADDRESS (Including Apt., Una, SuEe, mWor t11ep. No.) OR P.O. ROUTE AND BOX NO. Canlpery 11AiC NuRlber 813
212 W. 20` Sb*M
CITY STATE ZIP CODE
aANFORD FL 3ZT72
PROPERTY DESCRIPTION (Lot snd Block Numbers, Tax Pnoel Number, Legal Description, etc )
LOT 142, SANFORD HEXWM ADDITION. PLAT BOOK 2, PAGE 62 BEWNOLE COUNTY
BUILDING USE (e.e., Residential. Nw4astderft Addition, Accessory. sec Use a Cormwds area, if neoeseary.)
RESNENTIAL
LATITUDEA"44TUDE (OPTIONAL) HORIZONTAL TUM: E: 0 GPS (T`ype):
W - W - *N.W or 80.0 O NAD 1927 MAD lees O USGS quad Map O Other Q
SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION
Tet. NFP COLaMJNrTY NAME a CO MI1NRY N LMER Bz 00WTY NAME 03 STA-TE
CRY OF SANFORD 120M I SEMINOLE FLORA
81. MAP AND PANEL Bi'. FRM PAIELL B9.IMSE R, ATIOM
Nl1MBER MOWN B& FIRM NM DATE EFFECTI1lElR MSED DATE FLOOD WAS) FLOOD AS) Riau AO. ass dap h d bo ft)
12117000IS E APRIL 17.1995 4L17-191i5 X NA
ow. sarkaae me saunas a vro Hare HOOD erevnnsan (feral mar oasesoot cape enterea mug.
AS Praha ® FIRM Cormurdy DelerMned Otter (Desdbe):
811. Indicate the elevation dam used for to BFE In 89: ® NOVD 1 W9 NAVD 1988 Odner (Deacba):
B12 [aft bu1dng located Ina Coastal Barter Resawes %vAam (CBI sea a 01awtse Prolersted Area (OPA)7 Yes ®ND Designation Date
SECTION C - 61ALDING ELEVATION WFORMATION (SURVEY REQUIRED)
C1. Bnddmg klleraions aIe based on Comhoon DraAings" &MV Under Canstkuction' ® Fhbhed Co OWion
A nw t:levadan Caft to wi be reglfrod when mmmx9on d the W" is , r gi e m
C2. BuldrnB Dagram Number I (Select the build'ng diVa n most sh niter to the bkdldeng for which ones eerdAcete is hi g competed -see pages 6 and 7. n no degram
WWA* ropmeents Me bd6ng. provide a sketch or, r , - 9r 1 F
1.)
C3. Bew4ons — Zones Al AM, AE, AH, A *th SFE), VE, V143D, V (w@tk 8FE). AR. APIA. AR/AE, ARIA1 AM, ARfM ARIAO
COTO Os Itsos C3.41 bebw a000dng b Cue bdlding dVam i; P Aed in Mom C2. State the datum used, fl the dmm b dif ip from the dalum used for file 8FE in
Sermon B, Mwelt the datkrn to d at used far the BFE. Show Held measurements and datum conversion kalculaW. Use the space provided a the ccimmerm area d
Section D or Section G. as applDpAate, to d=ment Cue datum amersion,
Datum NGVD29
Efevadon rdarerrce mark used SEMINOLECO. Does the elevation reference man, used appear on the RRW p Yee ®No
o a) Top of bow. floor (ndkdvkg basement a trrdoeure) 50 711.(m)
D b) Top of reod hvW Moor M R (m)
o c) Bottom of lowest haiamw structura member (V zon= only) NA 11(m)
o d) Atachad garcqa (lop of tdab) 50.4 A.(m) o
o e) Lowest elevalon d machineryinery andta equipment
swidtg fie building (Deeonbe in a Cwnw b area)
u Q Lo*W (ANC VWB (LAG)
o 9) edleoerrt (birched) grade (HAG) 114m)
o h) No, of permanent openings (W vent) Of in 1 A. above a0ml grade NA
T0i) anal area d at pemanenl opersngs (Aeon vents) In C3A NI sq n. (sq. can)
Gs .Soo6
SECTION D - SURVEYOR, EIM EER, OR ARCI`ff ECT CERTIFICATION _
This oertific4on is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation inbrnabon.
I CerfltY hW Ma information in Sedtons A, d and Con this ceditafe eprosentr my best afiats to Inferpret the date available.
I_understand that any false stetement may be punlshabla by fine or imprisonment under 18 u. S. Code Section 1401
CERTIFIERS NAME MARK I. LUKE UCOM NUMBER LS SON
Tm.EMANAGING MEMBER COMPANY NAME MENRICH-LUKE & S NAGGERTY, LLC
ADDRESS - - -- CRY STATE ZIPCOOE
PhMA ecru 07-31. January 2003 See roverse side for continuation. Replaces all previous editions
03/23/2005 14:57 4076478097 HENRICH PAGE 02
IMPORTANT: to MNM spacm copy flee consmilpariding hdormaon Itrom 5 o ri' m tt A. Fa simsmos cam Liew
MADINGUSKOAN 86 (kbrdt+o Apt. Unt Sufi ands' Bft. ND,)OR P.O. ROI1}E ANIDWX NO. Pulpy Mardsr
212 W.20TM STREET
C1Y STATE DPCOOE CarnpmvWxmimm
SANFORD FL 32TT1
SECTION D - SURVEYOR, ENGINEER OR ARCHITECT CERTIFICATION (CONTINUED)
Caps both aided d M emrellm Cerolcaw tr (t) ao mwty deoa+, (2) irlsumm aperNamWny, and (3) boding omw.
COMMENTS -
LOWEST MACHINERY SERVICING BUILDING IS AIR CONDITIONING EQUIPMENT
Clack here if elleahmenb
SECTION E -BUILDING ELEVATION INFORMATION (SURVEY NOT REQUM FOR ZONE AO AND ZONE A (WITHOUT 13FE)
Fa Zone AO and Zane A "tut BEE), mnplete bon El ftwo 64. d Ire Elevdm Cefrats is irbnde0 for use as saw" Mortnab for a LOMA or LOMRf,
Secrom C must be mrpeled.
Ell. Buldtg Dlegram Number _(SdW the bukkV &Von moss strr6ar b one b f*g for whldt Iris aertili r to Is bertg dompfeead — see ptpee 6 and T. a no dagram amurately
mvewft ttne buldrg, provide a etAIch or pabgraptt.)
E2. The top d fie bwn. Ioor (ndu&V beaernerd or endmure) d Ire bul]&V is _ R.(m) = .(on) above Of below (do* one) the hgheet a mm grade. (Use
naMW grade. IavMable).
E3. For &A*q Diararrrs 6-8 w M d v*W (see page 7). the nerd higher lbor or elevated floor (elevedon b) d Ire building is , fQm) _Irr.(an) above the hoW m Went
Bade. CoTom meHans C3 h and C3.1 m Oarnt d lam. EA.
The top d the plaftm d mmdnir m andbr eoiugment eervWv Ate bulk" Is _ k(m) _n.(an) above a below (do* me) the OW agaoau graft (Use natural
glade, I available). E5
For Zone AO only: I no food duff , unbei is a+al 0e, is the lop d the bWom nod devamad in amwdunce wM ore mmnturtltys Aoogplain managemeM arjrnartoa7 Yes
No Uhlmm. The foal 09*211 mud Derry ors Intoenabon in Sealm G. SECTION
F - PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CE MCATION The
property owner a om a a dvized mpwenlaM who oomph Sums A, B, C (Items C3.h and C3J only), and E for Zoe A tmMl i a F EMA4n uad or amts mty- mmW
BFE) a Zom AO must sigh hart T1r9sit wv is in Sadma A, A q end E am =- fo the best of my furoaft0m PROPERTY OWNER'
S OR OWNERS AUTHORIZED REPRESENTATIVES NAME ADDRESS CRY
STATE DP CODE SIGNATURE DATE
TELEPHONE COMMENTS Chafe
here
d dlEedMMIs SECTION G -
COMMUNITY INFORMATION (OPTIONAL) The bcal
dbal aft b aut orized bylaw a ardinarim to adrrird r fhe w tv nitys Aooclplaln maragemerq ardnmm can oo no* Sections A. S. C (a E), end G d this Elevation Cerfditale. CW0e1a
the Ibtrnn(s) and go below. G1. The
irdarr eft in Sacdm C arras oaken tram dha dorunart0m Itaf has been signed and ernbomd by a kpnsW virvep. engineer, or arched who is authoriaed by sine a bcA
lacy to oemity elevation mklmvtm. (kndrate the soeoe and dale d the elevaton data in Ote Cam h eta baba.) GZ A
ommu ry di dal completed Section E fa a bui N bead In Zone A (wftA a FEMAa umd or cmmniy4ssnued BEE) of Zone AO. G3. The
Ietibwirg dwnabm (Ifm G4(39) is pm dad for =m u* Aoot>iiain n mpmm purpma. G7. T1m
MM has been issued far. New Co ulrumm S% betaitlyd rnprdvmnem G8. eavation
all as.brdt bond nemr (wKkx rp bmernem) d dne bu d% oK _ _A.(m) Daunt G8. 6FE
or (in Zone AO) depth d lbod M at fhe bul"site Is: — _ A (m) Datum _ LOCAL OFFICIALS
NAME TITLE COMMUNTrY NAME
TELEPHONE SIGNATURE DATE
OOMMENTS Check
here
It 8ltethmettta FEMIA Fonn
81-31, January 2003 Replaeas all previous editions
March 15, 2005
Engineering Department
City of Sanford
Sanford, FL 32771
To Whom It May Concern;
Subject: Driveway
Permit #04-2405
212 W 20"' Street
Sanford, FL 32771
At the time of our submitting for a permit for building a residential home at the above
address, included in the package, was a plot plan showing the drive entering off the alley
with the drive stopping before the property line and a curb cut on 20`h. St. Before
reviewing the contents of the permit and talking to the Engineering Department they
stated they were not allowing any curb cuts on 20`
h street do to traffic flow.
However, upon reviewing our permit, it was discovered that we did received a permit for
driveway installation in right-of-way as shown on plot plan at time of submittal for
building permit.
After starting construction of the home and seeing the amount of traffic on 20`
h Street.
We decided to take the Engineering Departments advice and installed only the driveway
in rear of home, to use the alleyway for entry.
The permit was not used and this letter is to request that the permit be removed/cancelled
for the final CO of home.
Sincerely4&
Paul aamesA. K. Blagg J 0'
Owners/Builders
i
y
l
3
4 rj
24 GA. STEEL skim (5) WIOWEDMi STILES FOR It WIDE OOOIL
REV. N0. Z
1
I/5• oso!'T" L
A 1
I
S[[
I
N
REVISIONS
DATE: ECN NO. APPVD: DESCRIPTION
11/0o I - — I OTY (1) WAS (2) FOR TRACK BOLT
INOWEORK TRACK SROT BY
m G IRN. OO SrILD ATTAOm IO DOOR DOOR VISTA= (TO Sv0SONWITHPATENTEDTOC-L-LpC sTSTOJ
cTD.. BOTTOM . JTTm
uAG1u rxv. sTm rue suaxr.
a) S%LW LAG i 11S
LISTED80IC DaALE TRA«
m&cK_Q EQzA H LOW HEANALARbD.rnN BODR
VIEWrNOOKrCA' . .
T Kn.ammnw I=
POSITION WIN
SNr iDDo,u (Tr. .
L
x Ers Rv.S TRAoL Hunan. REPORT#
9606C LNR
Ha.
xaNTAL 3•
20 CA.u-6Ma PAPATrEXNN (
Li TWO U 1M OMMYWAF DwIITDNN ON
BOTTOM SD:MK ONE
U-MRS ON Km SELTIOK
ETC.) SIM
LET LDunoN
or 1 OnONAL
VENTS R1 • OPIIONAL oursoc KEYED I= OSTON MAIL
0001 W10M IW_0- W®
E ELEVATIONS NOTE
I. DOORS
11 TO r-0. 1ILCN Na3N95T OF a) sECigN6 (O qIM . ) FRONT FRAME WITH u.V. i194J]t R 91lW LC ISOEt7 11Af 1 oA Doo1a
OKR r-w HIOI 00NtSST or ( 5¢TIDrNs (N oanxc a ouTSCc swALC WOf
NOT ImURD) TO /VOICE A PAISH MOLVOC SUEACL
HORIZONTAL 4UM 00 NW IRNaU LD16 M
TOJpr RWE LN 1
F- x' nwx GAtS dl amm" Y a
EA MINI. STEEL . SON
COATED WIN C-NO MUN CALVMNxING.
WAJCED-0OM POWER. AND
A UIxD-ON PO.r670 TOR
COAT APPLIED TO BOt1N SCES
OF STEEL SIGN. SHIP
W JOINTS. 3•
TILL U-OM 20
G CKv. STEEL N
I N. IM STRE NCTH: 50 R9 Ld
3• I 1-
7/W' T
SECTION
A -A (SIDE NTWI 4
MOLDED
INSIDE 1" •'
TK LED -IpN
R-n L
LITE
ACTANER ,ya/.•
Nw HEAD saEW - Ix
G CIW. sTm TR.ACI MAC
ETS FASIO[O TO WOOD JAY 10
SCREWS PER LAZE) ... ANICCRs ON xl WIN ONE 5/1r.1-5/W LAC MILL WLDrx)
a EN• f>Df1O6 PR MN. (00 CE E) 01 RU MAC( OIAORT @:
KT
MEWS
I
1/
A•J A• SELF MlWS. 31f
nn MNIf,1 In LA VNTRIiI11ATF N.NCE sw LNDLu*
c A DOOR VSTALlO1 (W SIM rx0 G
AM. CALVE SM OD STILL 20 G
CALVE STEEL VIOL. STILE fi7 C
0
J/
112
CA.LER E.K T.v. STEELToSNAP UTON fHOL7<S SI1f1NONTO. Toom WIp2TLr49eTaW1hl4DRIM - CENTERS JI `r/IASRNG (am PPut r) IW I.
A. cALv, SIEFL CCMFII IRNf' TTACH WRIOKET
ATTACHEDr/(I) WIER. STILE
ONE SNIPLATCH
tU CTONNEACH90C
W 00011E REEVE ANCINOItS,
1. 0O MN, WASINU RECIRED E' CALv. SIM TRACK FASTO/ED P I. G CKv. WITH fAPEpa. NN01016 wr WE A FLUSHSLWf IE G CALV. STEEL TRACK G ACRETS FASIOEO f0 CSIEO$T EACH ) FII ID 1NTO1. E r(a DTI NOTWAIRD) To rNIOr 0, A NA9N W SKET tETK MlWS. II.S/
W" METAL YOI.NIILNC TRACK ATTACHED TO TJLN WRIGR7 /IIId/E YETJt NOIL2ORK JAIf CO NOT WITH ONE 1/A•d/W BOLr R No `I) IJi•J/SA UDR SCREWS IV 00 IRINCC OUTSIDE IQl'
m LOAD.SURFACE.
IRAI19T11LOAD. ON two
I/A' IRA RNKIS II G
C.Q.V. STEEL HANDLE END
x'
OIL SHORT -STEM. 10 RALL SIM ROLLER. CND MIKE.
EACH FASTENED TO
STILE Dam
yOj
j)m MARK WESTERFM . PL STILES r/(
A) .s/W' INSIDE NANDLE COL FNIFPIIt.Anm OF J RY QtvOI [-c 144495PZ SHEET KfKNORTHRNORMCAROIMPL /23672 LOCK &AR
TAPPING SCREWS,SWtR eM.w OUTUDEE ENPXES
IN
TRACK ON
tIE DE9C" OF T1E SUPPORnIG StRAnuw. OEI10NI5 DESIGN LOADS: +24.0 PSF & -24.5 PSF EACH SIDE
THE REsvN9euTT OF THE PROFESSIONAL OF TEST LOADS: +36.0 PSF & -37.0 PSF a• WALL .
ID a Exv. SfOl u-BA16 FxD HANDLE SDE
ROLL
OF DOOR. RECORD FOR THE WIAIDRIC OR SIlWAA E NO IN ACCORDANCE M A
x_N-x-I R.rTEJM (IL TWO u-OARS SRE IQ7f FNG1G[S wIN aRWtnNr rNLaDDNc cents FOR ra LlYOS LISTED a THIS CURRENTQK,t; PARTNO.: - ON BOTTOMSECItONN. ON( U_w ON NEXT SECTION Eft.
z WI M-.NI ARAOED INTO MERI
AL TRAiX Oro
rD,a: e WlM 1
I•J// SOf rl~ SCREWS Ras LDUT1w.
IOC( ON
un SIDE
y.y
r anr•
T "` "nm as m s aNM"
TOLERANCES . IDEAL
312 .dRE a SuL 1600 cR °"^De
4H 451a2 Di 00011E
r O 'L 0 - 1.03 INL 11a
I!W-451-Taro W r
WOa QNOMrL Ea N& 1-513-752-3511 I ovr -=
13 a
CAm STEEL 00 At &RACKET. ATTACHED WITH (
x) 011.5/W' BEET METAL MtEWS i RF
r_...A rr. r WI' ^ -+F —
A i, N+Wb
Nr " W.•-P r 00 - t •
015 000 - t.
005 OODO - t.
001 DESCRIPTION: MODEL
6RST Wa 16-0 8-0: 24/-24.5 DESIGN LOAD DRAWN BY:
BMM DATE: 4/18/00 SCALE: NTS OWO. R En> S
ZDl. naAIYW w..W.n 049 an - t I/Y CHECKED BY: MWW DATE: 4/18/00 SHEET I 1 SIZEMUM L HERSTRIP., TMFaAnglePFojKOL1N1LAV.
sR Stated 0Wvr1N- OF OMEnSIDtNs
ARE
W WNC/E5 OWE. NO.: 102138 REV. NO. I 3 2
dRAAE Co JJA"_lY' BURDIN4 DIV.
ONE BY VOIID DETAIL" 2000 Sx 1 X 2 7/16 X U8 ' 2000 SA I X 2 7/16 X 3/8 j
B (TYPJ TUBE 141LLIDN. JAMB MID.) TUBE MULLION I BUpC' BY OTHERS
CONCRETE OR MASONRY
1 U4' MIK BY OTHERS
EMBEMMENT
I8 X 1/2 SELF IB X 1/2 ,SELF
TAPPING SMS TAPPING SMS
DNSTALLATIDN ANCHOR 3/16•
TAPCUN SCREW ANU47R RYPJ .
EXTERNAL Ml1LLMN
DISTALL'ATMN . QIP
SEALANT BETWEEN 7. SEALANT BETWEEN - .-TUBE 14lJl.L,IDM
WINDOW FLANGES VINIM FLANGES xi !- .r
a MULLttIIN
18 X 1-1/2 SELF
a Mt LLIGN 2000 Sx' TYPICAL FIUIIJON 'TO ;CONCRETE O HEAD
TAPPING SMS
I8 X 1-1/2 SELF
TAPPING SMS
JAMB CTYPJ
i
MULLIIIN APPUES. TO`. HEAD.:d: SILL.WHERE I' X 4
4'_ TU8E' MULLIONS ARE USED)
SECTION A -A (1) SECTION A --:A (2)
IX4XU8
TUBE MULLION
2000 S.H. 2O00 Sit
JAMB (TYPJ JAMB TYP
I8 x 1/2 SELF -
TAPPING SMS". . -- __
I8 z 1/2 -SELF. DEIAL_B
TAPPING SMS
a•' INSTALLATION AN(iflR
I X 4.X 3/0.
AFCiNQR
3/16• MA -TAPCOI
SCREy C YPJ
TUBE MULLION
SILL CLIP
I8 X 1-1/2'SELF
7APPING_SMS
SEALAMT'1TVE01 Q"
WINDOW FLANGES -. - -
t MULLD]TI " 1 U4• MIN.
SECTION A=A'(5) ' — _-Q_: `t. _
Q EMBEDMENT
s
DETAIL C-. - ` _
PR_C11ST SILL BY-DiINERs .
AUXIL ARY.' PLATE ,.. Ie x t/z SELF - ..... ..
TAPPING SMS — _(FOR_ADDITMNAL - ANCWRS VFtEDIREOUIREM
SEALANT BETWEENSEALANT BETWED; VDNDOW
FLANGES VDGUV FLANGES . - --- a
MULIG N t MULLI@I : I8
x 1-1/2 SELF tiB x i-I/e SELF Ie
SELF TAPPING \ TAPPING
SMS TAPPING SMSnZATUS SMS:
RYPJ : .. . ` DETA BLI(]Pt ' O • .
SECTIONA -A (3) SECTION A -A (4) SEWED FRom EXTERIOR C
cWri '' FLQRIDA EXTRUpERS Oxu, I FAG"
I'R • PIAI : , r • SANFbRD,MANU>:'
1.0Rma. i o
i v. S T S R. 00 ANG r, SHEE 1.- i, ; 17
VA VERTICAL MULLION•SECTIOt S SEE -
OTHER.; S:I•DEz;SHEET.:'2-,OF•'2) fDR: : 1B ?lD? DESIGN PRESSURE -CAPACITIES. ,' DRAWN
ErY: JBH , t Rif ' '.APPR09ED"HY:?2at , ^•,`n. 1- DAT1a2/
2/.02. SCAIE:,NTS D51G ' 2V[i
92-0-0
66-0-0 26-0-0
3
7- -6
7
EJ7
EJ7
EJ7
J
ao09,49
o,
0
a,
m
0
o
p
N
0;
5-0
O O
4 0- I
co
0 0 0j o d o 0
12 P
4
7 PI
0 0 0 0 0 0IT
h,
7-
7
EJ7
EJ7
EJ7
J5
0
N
c
J7
EJ7
FEJT77
7'0-0
EJ7
EJ7
EJ7
cJ5
Lr
3 MI
V1
11
8-0- 84-0-0
APPROVED TRUSS ANCHOR BY BUILDER
SOURRE CUT OVERHANG
HEEL HEIGHT = 2x4 STD.
BOTTOM = 2x4 MIN.
12TOP = 2x4 MIN. 6
All walls @ 9'-4" A.F.F.
12
Hangers
J L HUS26 (06 required)
1 •-4'
TRUSS END DETAIL
NOTES :
I) 0 991 IRMMUM
E M FOR MGM
mm MU
M DGNM IR IM FOR F4dIiERT
ffmc PID11Ell 21
lu MIMS mulm mm UDR
tRM H IW MIST
a ang aT am k
UR m IFIR UI05 i IETR
M05 FOR aTONNE HR76
1XIME nS 3)
ILL IR1EYS M E MUMIFur FMG
BY HIM 41
ILL W S SMW FIE MW 5)
ROM .ITS MY BE IflIlS1FD MY
FOR as STUB' IWIM 6)
RDR IF DI F 1 N IIL KIM
m offlum 7)
M RM MIST BE W1110 Im
TIE TIP 06 IF. 81
ILL n
new gm 9)
ILL RIXR TIIM M M M BE 2FO MIN
ULM WE 9DEN1 Obilders
FirstSourceSanford
Truss Division 2901
Polervl CIrde Sanford.
Floyd 3!M 407)
322-0059 Fax -1407) 322-5553 1-
888-946-5637 O
y JN0 0T
cm lLp ~2 0 2
Wy O
yW F-
Jyd'w clN
LmU20 SW p[y aa-
KU= . v O
F-
Wy =
W=X U
K W 0
00 V%
aJWm Z =
Wa WOUJ W
QyWJd.
CE:
W SUS 02
W--S O
y JmW e lGfn—=
cr- 2
yy 2 c,)
Jy a O
T
y2"WOm2 .+ 1 =SY S v H1-
OJmU p Q w..
Bumilders 2901 Aileron Circle
First Source
Sanford, Florida 32773
407) 322-
5553Fax(407)322-5553
DATE: 03/29/2004 Designed By: S. Caponey
SUBJECT: State of Florida Truss Cover Sheet — Rule 61 G 15-31.003
Design of Structures Utilizing Prefabricated Wood Components
ENGINEER: Randall Byrd, P.E. # 23451 (321) 630-0231 Beeper
2325 Jason Street (321) 453-6564 H/O
Merritt Island, Florida 32952 (321) 453-4187 Fax
CODES & CRITERIA: FBC-2001 Sec. 1606, ASCE-7/98, ANSI/TPI-95, HIB-91,NDS-97, and ASTM A653
Design Loads -Shingle Roof: TCLL = 20, TCDL = 7, BCLL = 0, BCDL = 10; Total Load = 37 psf / LF = 1.25
Wind Speed Loading: 120 MPH, Exposure B, Condition 1, Partially Enclosed Building, Category 11
REFERENCE:
Job Number: Master
Job Date: 03/29/2004
Number of Truss Profiles: 17
Builder: Blagg
Lot & Sub: Blagg Residence
County, State of Job: Orange, Florida
The truss drawings referenced above have been designed using MiTek 2000, Version 5.201 SR -I, by MiTek
Industries under my direct supervision based upon the parameters provided by Builders First Source..
F\, L A.
23451
0
STATE OF •:
Mardh 29,12004
The seal on these Drawings indicate acceptance of Professional Engineering responsibility solely for the tkjss
components shown. The suitability and use of this component for any particular building is the responsibilily of the
Structural Engineer -of -Record (Building Designer) per Chapter 2 ofANSIlTPI 1-1995.
0312912004 - 8:41 AM
Single Family Release Order Acknowledgement By:
Builder: Blagg Job No: Temp SAEng52 BldrDii BLAGG
Subdivision: Orange Pick Ticket: SAOrd52 BldrDii BLAGG
State: Florida Sales No: Model SubDir: BLAGG RESIDENCE
Lot: Blagg Residence AccNo: Release File: Temp
Model: Custom Ship Date: Master Truss File: Master
Shipment. Roof Designer: S. Caponey Layouts:
Elevation: Source Folder:
Option: Job Destination:
Truss ID Totals Price Quantity
c' 1 8
c'3 8
c'S 8
ej7 18
hj7 4
t01 1
102 3
t03 4
1:05 2 1-2P1
t05a 2 1-2P1
t06 21
t07 2 1-2P1
t08 1
t09 1
110 8
t11 3
t12 2 1-2PIy)
Total I 96
Hangers IHUS26 6
Seat Plates 1 175
MAR 2 9 2004
m Builders FirstSource, Inc 2002
lei
1 n+ss 1 We sty Fly tsiaggi rnagg Kesidence/ sec
MASTER' CJ1 ROOF TRUSS 8 1
Job Reference (optional)
Randall Byrd, P.E. #23451. 23235 Jason Street, Merrill Island, FI. 32952 (321) 453.6564 5.200 s Seo 30 2003 MITek Industrie
t]
i
scale •15
1-0-0
1-0-0
LOADING(psQ SPACING 2-0-0 CSI DEFL in loc) Well Ud PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.19 Vert(LL) -0.00 2 >999 240 M1120 249/190
TCDL 7.0 Lumber Increase 1.25 BC 0.01 Vert(TL) 0.01 1 >999 180
BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a
BCDL 10.0 Code FBC2001/ANSI95 Matrix) Weight: 6lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.3 TOP CHORD Sheathed or 1-0-0 oc purlins. BOT CHORD 2 X 4 SYP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing
REACTIONS (lb/size) 3=33/1V!echanical, 2=16710-8-0. 4=9/Mechanical
Max Horz2=670oad case 5)
Max UpliK3=33(load case 1). 2=-149(load case 5)
Max Grav3=380oad case 5). 2=167(load case 1). 4=18(load case 2)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=0131, 2-3=-41/19
BOT CHORD 24=0/0
NOTES (5)
1) Wind: ASCE 7-98: 120mph (3-second gust), h=25ft: TCDL=4.2psf; BCDL-5.Opsf, Category 11; Exp B: partially; MWFRS interior zone; cantilever left and right
exposed ; end vertical left and right exposed: Lumber DOL=1 33 plate grip DOL=1.33.
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads per Table No. 16-B, UBC-94.
3) Refer to girder(s) for truss to truss connections.
4) Provide mechanical connection (by of of Wss to bearing plate capable of withstanding 33lb uplift at joint 3 and 149lb uplift at joint 2. 5) Randall B axon Stree s a rida 3 os2ra.M 453-6564 LOAD
CASE(S) Standard MAV
2 9 2004 s
Job Truss Truss Type Oty Blagg/Blagg Residence/sec 17
MASTER CJ3 ROOF TRUSS 8 7r Job Reference (optional)
Randall Byrd, P.E. #23451. 23235 Jason Street, Merritt Island, FI. 32952 (321) 453-6564 5.200 s Sep 30 2003 MiTek Industries, Inc. Mon Mar 29 08:36:42 2004 Page 1
1-4-0 3-0-0
1-4-0 3-0-0
raY • 17
6OD IT
TI
1
1
34=
4
3-0-0
3-0-0
LOADING(psf) SPACING 2.0-0 CSI DEFL In (loc) Udefl Ud PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.25 Veri(LL) -0.00 2-4 >999 240 M1120 249/190
TCDL 7.0 Lumber Increase 1.25 BC 0.11 Vert(TL) 0.03 1 >783 180
BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(fL) -0.00 3 n/a n/a
BCDL 10.0 Code FBC2001/ANSI95 Matrix) Weight: 12 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.3 TOP CHORD Sheathed or 3-0-0 oc purlins. BOT CHORD 2 X 4 SYP No.3 BOT CHORD Rigid ceiling directly applied or 10.0-0 oc bracing.
REACTIONS (lb/size) 3=42/Mechanical, 2=215/0.8-0, 4=26/Mechanical
Max Horz 2=1 20(load case 5)
Max Uplil`0=58(load case 4), 2=142(load case 5)
Max Grev3=42(load case 1), 2=215(load case 1), 4=52(load case 2)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=0/32. 2-3=-50/14
BOT CHORD 2.4=0/0
NOTES (5)
1) Wind: ASCE 7-98; 120mph (3-second gust); h=25fl; TCDL=4.2psf; BCDL=S.Opsf; Category It: Exp B, partially; MWFRS interior zone; cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL-1.33 plate grip DOL-1.33.
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads per Table No. 16-B, UBC-94.
3) Refer to girder(s) for truss to truss connections.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 58 lb uplift at joint 3 and 142 lb uplift at joint 2.
5) Randall Byrd, P.E. # 23451, 2325 Jason Street ,Merritt Island, Florida 32952 (321) 453-65640
LOAD CASE(S) Standard
Job Trusa Truss Type Oty Py Blagg/Blagg Residence/sac 17
MASTER CJS ROOFTRUSS 8 t
Job Reference o tional
Randall Byrd, P.E. #23451, 23235 Jason Street, Merritt Island, FI. 32952 (321) 453-6564 5.200 s Sep 30 2003 Mf7ek Industries, Inc. Mon Mar 29 08:36:43 2004 Page 1
1-4-0 5-0-0
1-4-0 5-0-0 3
3.1 •113
l oo 11
TI
2
51
1
a.=
5-0-0
5-0-0
LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIPTCLL20.0 Plates Increase 1.25 TC 0.38 Vert(LL) -0.03 2-4 >999 240 M1120 249/190TCDL7.0 Lumber Increase 1 25 BC 0.34 Vert(TL) -0.07 1 >287 180
BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(rL) -0 00 3 n/a n/a
BCDL 10.0 Code FBC2001/ANS195 (Matrix) Weight: 18 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.3 TOP CHORD Sheathed or 5-0-0 oc purlins.
BOT CHORD 2 X 4 SYP No.3 BOT CHORD Rigid ceiling directly applied or 10-0.0 oc bracing.
REACTIONS (lb/size) 3-108/Mechanical, 2=277/0-8-0. 4-46/Mechanical
Max Horz2=174(lood case 5)
Max Uplil`0=125(foad case 5). 2=-150(load case 5)
Max Grov3=108(load case 1). 2=277(load case 1). 4=92(load case 2)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=0/32, 2-3=78/40
BOT CHORD 2-4=0/0
NOTES (5)
1) Wind: ASCE 7-98; 120mph (3-second gust); h=25ft; TCDL-4.2psf; BCDL=S.Opsf; Category II; Exp B. partially; MWFRS interior zone; cantilever left and right
exposed : end vertical left and right exposed; Lumber DOL-1.33 plate gnp DOL-1.33.
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads per Table No. 16-B, UBC-94.
3) Refer to girder(s) for truss to truss connections.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 125 lb uplift at joint 3 and 150 lb uplift at joint 2.
5) Randall Byrd, P.E. 0 23451. 2325 Jason Street ,Merritt island, Florida 32952 (321) 453-65640
LOAD CASE(S) Standard
Jab Truss Truss Type Oty Ply Blagg/ Blegg Residence/ sec 17
MASTER EJ7 ROOF TRUSS 18 1
Job Reference (optional)
Randall Byrd, P.E. #23451. 23235 Jason Street. Merritt Island, Fl. 32952 (321) 453-6564 5.200 s Sep 30 2003 MTek Industries. Inc. Mon Mar 29 08:36:43 2004 Page 1
1-4-0 7-0-0
1-4-0 7-0-0 3
k.,4. ,.n
2
a.=
s,
4
7-0-0
7-0-0
LOADING(pso SPACING 2-0-0 CSI DEFL in (loc) Udef1 Ud PLATES GRIP
TCLL 20.0 Plates Increase 1 25 TC 0.90 Vert(LL) -0.10 2-4 >794 240 M1120 249/190
TCDL 7.0 Lumber Increase 1.25 BC 0.40 Vert(TL) -0.23 1 >88 180
BCLL 0.0 Rep Stress Incr YES WB 000 Horc(TL) -0.00 3 n/a n/a
BCDL 10.0 Code FBC2001/ANSI95 Matrix) Weight: 24 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.3 TOP CHORD Sheathed or 6-0-0 oc purlins.
BOT CHORD 2 X 4 SYP No 2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) 3=167/Mechanical, 2=346/0-8-0, 4=66/Mechanical
Max Horz2=229(load case 5)
Max Uplift3=190(load case 5). 2=-167(load case 5)
Max Grov3=167(load case 1), 2=346(load case 1), 4=132(load case 2)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-2.0/32, 2-3=-115/62
BOT CHORD 24=0/0
NOTES (5)
1) Wind: ASCE 7-98; 120mph (3-3econd gust); h=25ft; TCDL-4.2psf; BCDL=5.Opsf: Category 11: Exp B; partially; MWFRS Interior zone; cantilever left and right
exposed : end vertical left and right exposed; Lumber DOL-1.33 plate grip DOL=1.33.
2) This truss has been designed for a 10.0 psf bottom chord live toad nonconcurrent with any other live loads per Table No. 16-8, UBC-94.
3) Refer to girder(s) for truss to truss connections.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 190lb uplift at joint 3 and 187 lb uplift at joint 2.
5) Randall Byrd, P.E. N 23451, 2325 Jason Street ,Merritt Island, Florida 32952 (321) 453-65640
LOAD CASE(S) Standard
Job Truss Truss Type Oty Ply Blagg/ Blagg Residence/ sec 17
MASTER HJ7 ROOF TRUSS 4 7
Job Reference o Lionel
Randall Byrd, P E. 023451. 23235 Jason Street. Merritt Island, FI. 32952 (321) 453.6564 5.200 s Sep 30 2003 M1Tek Industries, Inc. Mon Mar 29 08:36:43 2004 Page 1
1-10-10 5-2-5 9-10-13
1-10-10 5-2-5 4-8-7
x.r•1
14s
x. 7
TI
W Mil
2
elLJ
r
a'4 u
T
5
s.. _
3.4 =
5-2-5 9-10-13
5-2-5 4-8-7
LOADING(psp SPACING 2-0-0 CSI DEFL In (loc) I/dell Ud PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.44 Vert(LL) -0.05 6-7 >999 240 M1120 249/190
TCDL 7.0 Lumber Increase 1.25 BC 0.87 Vert(TL) 0.08 1 >345 180
BCLL 0.0 Rep Stress Incr NO WB 0.29 Horz(TL) 0.01 5 n/a n/a
BCDL 10.0 Code FBC2001/ANSI95 Matrix) Weight: 42 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.2 TOP CHORD Sheathed or 6-0-0 oc purlins.
BOT CHORD 2 X 4 SYP No.3 BOT CHORD Rigid ceiling directly applied or 9-0-2 oc bracing.
WEBS 2 X 4 SYP No.3
REACTIONS (lb/size) 4=229/Mechanical, 2=426/0-11-5, 5=347/Mechanical
Max Horz2=279(load case 3)
Max Uplifl1=240(load case 3), 2=198(load case 3). 5=-116(load case 3)
Max Grav4=229(load case 1), 2=426(loed case 1), 5=3640oad case 2)
FORCES Qb) - Maximum Compression/Maximum Tension
TOP CHORD 1-8=0/28, 2.8=029, 2-3=720/175, 3.4=-104/56
BOT CHORD 2-7=387/656, 6-7=-387/656, 5-6=0/0
WEBS 3-7=0/316, 3-6=-715/422
NOTES (6)
1) Wind. ASCE 7-98; 120mph (3-second gust); h=25ft; TCDL=4.2psf; BCDL=S.Opsf: Category 11; Exp B; partially; MWFRS Interior zone; cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL-1.33 plate grip DOL=1.33.
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads per Table No. 16-B, UBC-94.
3) Refer to girder(s) for truss to truss connections.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 240 lb uplift at joint 4, 198lb uplift at joint 2 and 116lb uplift at
joint 5.
5) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or beck (B).
6) Randall Byrd. P.E. # 23451. 2325 Jason Street ,Merritt Island, Florida 32952 (321) 453.65640
LOAD CASE(S) Standard
1) Regular: Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (pip
Vert: 1-8=54
Trapezoidal Loads (pip
Vert: 8=0(F=27, 13=27)-to-4=-134(F=-40, 13=40). 2=-2(F=9, B=9}10-5=49(F=-15, 8=15)
Job Truss Truss Type Qty Ply Blagg/Blagg Residence/sec 17
MASTER T01 ROOF TRUSS 1 7
Job Reference (optional)
Randall Byrd, P.E. #23451. 23235 Jason Street, Merritt Island, FI. 32952 (321) 453-6564 5.200 s Sep 30 2003 MiTek Industnes, Inc. Mon Mar 29 08:36:44 2004 Page 1
1-4-0 9-6-0 19-0-0 20-4-0
1-4-0 9-6-0 9-6-0 1-4-0
3 M"1.34
4=
0
3
T
scoliT
4
6
T
p
7
T T
2
10
1
1 1
19-0-0
19-0-0
Plate Offsets X Y : [7:0.2-14,0-0-121[8:0-2-14,0.0.12],[9,0-2-14,0-0-12],-f10:0-1-0,0-0-2],[12:0-2-0,0-0.12],(13:0-2-0,0-0-12)[14:0-2-0,0-0-12],-[15:0-3.0,0-30]
LOADING(pst) SPACING 2.0-0 CSI DEFL in (loc) I/dell Ud PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.15 Vert(LL) n/a - n/a 999 M1120 249/190
TCDL 7.0 Lumber Increase 1.25 BC 0.08 Vert(fL) 0.01 11 >999 180
BCLL 0.0 Rep Stress Incr NO WB 0.07 Horz(TL) 0.00 10 n/a n/a
BCDL 10.0 Code FBC2001/ANSI95 Matrix) Weight: 94 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.2 TOP CHORD Sheathed or 6-0-0 oc purlins.
BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2 X 4 SYP No.3
REACTIONS (lb/size) 2-202/19-0.0, 15=133/19-0-0, 16=157/19-0-0, 17=115/19-0-0, 18-236/19-0-0, 14-157/19-0-0, 13=115/19-0-0, 12=236/19-0.0, 10=202/19-0-0
Max 1-1=2=147(load case 6)
Max Uplift2--139(toad case 5), 16=143(load case 5). 17=-120(load case 5), 18=-208(lood case 5), 14=-140(load case 6). 13=-120(load case 6), 12=208(load case 6). 10=167(load case
Max Grov2=202(load case 1), 15=133(lood case 1). 16-161(load case 7), 17=115(load case 1), 18=236(load case 7), 14=161(load case 8), 13=115(load case 1). 12-236(load case 8).
10=202(load case 1)
FORCES (Ib) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=0/31, 2-3=-114/61, 34=44/138, 4-5=-35/185, 5-6=37234, 6-7=37/223, 7-8=-35/144, 8-9=-44177, 9-10=-55/'35, 10-11=0/31
BOT CHORD 2-18=0/156, 17-18=0/156, 16-17=0/156, 15-16=0/156, 14.15=0/156, 1314=0/156, 12-13=0/156, 10.12=0/156
WEBS 6-15=-95/0, 5-16=-117/163. 4-17=-87/137, 3-18=166235, 7-14=117/161, 8-13=-87/138, 9-12=160234
NOTES (9)
1)•Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-98: 120mph (3second gust): h-25ft; TCDL=4.2psh BCDL=5.Opsf; Category II; Exp B; partially; MWFRS gable end zone; cantilever left and
right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33.
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see MiTek "Standard Gable End Detail"
4) All plates are 2x4 M1120 unless otherwise Indicated.
5) Gable requires continuous bottom chord bearing.
6),Gable studs spaced at 2.0-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads per Table No. 16-13, UBC-94.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 139 lb uplift at joint 2, 143 lb uplift at joint 16. 120 lb uplift at joint
17. 208 lb uplift at joint 18. 140 lb uplift at joint 14, 120 lb uplift at joint 13, 208 lb uplift at joint 12 and 167 lb uplift at joint 10.
9) Randall Byrd, P.E. fi 23451, 2325 Jason Street ,Merritt Island, Florida 32952 (321) 453-65640
LOAD CASE(S) Standard
Job Truss Truss Type Oty Ply'Blapg/ Blagg Residence/ 17
MASTER T02 ROOF TRUSS 3 1
Job Reference (optional)
Randall Byrd. P.E. X23451, 23235 Jason Street, Merritt Island, FI. 32952 (321) 453-6564 5.200 s Sep 30 2003 MTek Industries. Inc. Mon Mar 29 08:36:44 2004 Page 1
1-4-0 5-0-4 9-6-0 13-11-12 19-0-0 20-4-0
1-4-0 5-0-4 4-5-12 4-5-12 5-0-4 1-4-0
bY•IH
as =
000(3 2.4,1
W23
1
7.4 0
2
car
Soo
9-6-0
St=
Soo
19-0-0
9-6-0 9-8-0
Plate Offsets X Y : 5:0-0-12 0.0-12 [6:0.1.4,0-0-2][8:0.4-0 0-3-0]
LOADING(psf) SPACING 2.0-0 CSI DEFL in (loc) Wait Ud PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.40 Vert(LL) -0.17 2-8 >999 240 M1120 249/190
TCDL 7.0 Lumber Increase 1.25 BC 0.82 Vert(TL) -0.35 2-8 >620 180
BCLL 0.0 Rep Stress Ina YES WB 0.13 Horz(fL) 0.02 6 n/a n/a
BCDL 10.0 Code FBC2001/ANSI95 Simplified) Weight: 86 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.2 TOP CHORD Sheathed or 6-0-0 oc purtins.
BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 7-8-6 oc bracing.
WEBS 2 X 4 SYP No.3
REACTIONS (lb/size) 2=768/0-8-0, 6=768/0-8-0
Max Horz2=-147(load case 6)
Max Uplift2=-528(load case 5), 6=528(load case 6)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=0/16, 2-3=970/664, 3-4=726/498, 4-5=-726/498. 5-6=970/6(>4, 6-7.0/16
BOT CHORD 2-8=-594/851, 6.8=-463/851
WEBS 3-8=-237/380, 4-8=-196/409, 5-8=-237/380
NOTES (5)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-98; 120mph (3-second gust); h=25ft; TCDL=4.2psf; BCDL=S.Opsf; Category It: Exp B; partially; MWFRS gable end zone: cantilever left and
right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33.
3) This truss has been designed for a 10.0 psi bottom chord Inre load nonconcurrent with any other live loads per Table No. 16-B, UBC-94.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 528 lb uplift at joint 2 and 528 lb uplift at joint 6
5) Randall Byrd, P.E. X 23451, 2325 Jason Street ,Merritt Island, Florida 32952 (321) 453-65640
LOAD CASE(S) Standard
Job Truss Truss Type Oty Ply Blagg/ Biaggi Residence/ sec 17
MASTER T03 ROOFTRUSS 4 1
Job Reference (optional)
Randall Byrd. P.E #23451. 23235 Jason Street, Merrill Island, Fl. 32952 (321) 453-6564 5.200 s Sep 30 2003 MTek Industries, Inc. Mon Mar 29 08:36:44 2004 Page 1
1-4-0 5-0-4 9-6-0 13-11-12 19-0-0
14-0 5-0-4 4-5-12 4-5-12 5-04
bM • ,.33
a4O
3
a.
W! s
x
w,
9-6-0
r
19-0-0
3.4=
9-6-0 9-6-0
Plate Offsets X Y : 12:0 1 4,0 0.2j,[5:0 0 12,0 0 12][7.0-4-0,0-3 0)
LOADING(psf) SPACING 2-0.0 CSI DEFL in (loc) 11defl Ud PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.40 Vert(LL) -0.18 2-7 >999 240 M1120 249/190
TCDL 7.0 Lumber Increase 1.25 BC 0.85 Vert(fL) -0.36 2-7 >625 180
BCLL 00 Rep Stress Incr YES WB 0.13 Horz(Q 0.02 6 n/a n/a
BCDL 10.0 Code FBC2001/ANS195 Simplified) Weight, 84 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.2 TOP CHORD Sheathed or 6-0-0 oc purhns.
BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 7-6-8 oc bracing.
WEBS 2 X 4 SYP No.3
REACTIONS (lb/size) 6=685/Mechanical, 2=775/0-8-0
Max Horz2=162(load case 5)
Max UplifS=-420(load case 6). 2=-532(load case 5)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=0/16, 2-3=984/671, 3-4=741/507, 4-5--741/505, 5-6=1001/687
BOT CHORD 2-7=615/864, 6-7=520/886
WEBS 3-7=-237/379, 4-7=204/418, 5-7=-258/399
NOTES (6)
1) Unbalanced roof live loads have been considered for this design.
2) Wlnd: ASCE 7-98; 120mph (3-second gust); h=25fl; TCDL=4.2psf; BCDL=S.Opsf: Category II; Exp B; partially; MWFRS gable end zone; cantilever left and
right exposed ; end vertical left and right exposed: Lumber DOL=1.33 plate grip DOL=1.33.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads per Table No. 16-B, UBC-94.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 420 lb uplift at joint 6 and 532 lb uplift at joint 2.
6) Randall Byrd, P.E. # 23451, 2325 Jason Street,Merritt Island, Florida 32952 (321) 453-65640
LOAD CASE(S) Standard
Job Truss Truss Type Oty Ply Blegg/Blegg Residence/sec 17
MASTER T05 BOSTON HIP 1
Job Reference (optional)
Randall Byrd, P.E. #23451. 23235 Jason Street. Merritt Island. Fl. 32952 (321) 453-6564 5.200 s Sep 30 2003 MITek Industries, Inc. Mon Mar 29 08:36:45 2004 Page 1
r1-4-Q 4-1-0 11-2-0 1 15-4-0 1 19-6-0 1 23-8-0 27-10-0 34-11-0 39-0-0 10-4-
1-4-0 4-1-0 7-1-0 4-2-0 4-2-0 4-2-0 4-2-0 7-1-0 4-1-0 1-4-0
c44 • 1 a
34
m(1t
a.n a.0
R
2.411 2.411
L/4 7
s /
4 17
44
34
3
703
1/
ml
e10= 01 00 m L 77 mu 73 24 m ?l 2, e10=
2./r1 tr/= e/= ee= e.10= e/= 4x/= e/= 3./11
m= m=
4-1-0 11-2-0 15-4-0 19-6-0 23-8-0 27-10-0 34-11-0 39-0-0
4-1-0 7-1-0 4-2-0 4-2-0 4-2-0 4-2-0 7-1-0 4-1-0
Plate Offsets X : 12 0-5-0.0.1-7]119,0-5 0.0.1-71
LOADING(psf) SPACING 2-0-0 CSI DEFL In (loc) Well Lrd PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.87 Vert(LL) 0.19 27 >999 240 M1120 249/190
TCDL 7.0 Lumber Increase 1.25 BC 0.39 Vert(TL) -0.24 27 >999 180
BCLL 0.0 Rep Stress Incr NO WB 0.44 HOR(TL) 0.06 19 n/a n/a
BCOL 10.0 Code FBC2001/ANS195 Matrix) Weight: 681 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.2 TOP CHORD Sheathed or 5-2-13 oc purlins. Except:
BOT CHORD 2 X 8 SYP No. 10 3 Rows at 1/4 pis 4-17
WEBS 2 X 4 SYP No.3 BOT CHORD Rigid ceiling directly applied or 10-0.0 oc bracing
OTHERS 2 X 4 SYP No.2 'Except'
O22X4SYP No.3 REACTIONS (
lb/size) 2=3304/0-8-0. 19=2679/0-8-0 Max
Horz2=659(load case 5) Max
Uplifl2=-1696(load case 5), 19=-1437(load case 6) FORCES (
lb) - Maximum Compression/Maximum Tension TOP
CHORD 1-33=0/31,2-33=0/33,2-3--6371/3145,3-4=-6550/3332,4-5=-3671/1518,5-7=-3571/1537,7-8=3685/1825,8-11=-36762110. 11-
34=34912171, 12-34=36032168, 12-14=36272098. 14-16=-3571/1998, 16-17--3615/1989, 17-18=-51512742. 18-19=50622611. 19-
20=0/J8. 4-6=30922154, 6-9=2614/1729. 9-10=15537794, 10.13=15537794, 13-15=1841/1028, 15-17-1817/1070 BOT
CHORD 2-31=3350/5619, 30-31=-3350/5619, 29-30=-3442/5816, 28-29=3743/6285, 27-28=3743/6285. 26-27=3318/5808, 26-32=2442/5035. 25-
32=2442/5035. 24-25=2484/5010, 23-24=24B4/5010. 22-23=-2254/4579, 21-22=-2213/4457, 19-21=2213/4457 WEBS
4-30=-318/652. 17-22=30/204, 4-29=401/626. 6-29=196/355, 6.27=-638/548, 9-27-145/530, 9-26=1437/1226. 1D-26=15132725. 13-
26=-440/J02. 13.25=10/149, 15.25=89/209, 15-23=305253, 17-23=307/578, 3-31=317242, 3-30=178/J14, 18.22=110/198, 18-
21=246206.6-7=503/635, 8.9=-494/644, 12-13=185206. 14-15=-240259, 10-11=-15302752 NOTES (10) 1) 2-
pry truss
to be connected together with 0.131"x3" Nails as follows: Top chords connected as
follows: 2 X 4 - 1 row at 0-9-0 oc. Bottom chords connected as
follows: 2 X 8 - 2 rows at 0-9-0 oc Webs connected as follows,
2 X 4 - 1 row at 0-9-0 oc, Except member 26-10 2 X 4 - 1 row at 0-8-0 oc. 2) All loads are
considered equally applied to all plies, except if noted as front (F) or back (B) face In the LOAD CASE(S) section. Ply to ply connections have been provided to distribute
only loads noted as (F) or (8). unless otherwise Indicated. 3) Unbalanced roof live
loads have been considered for this design. 4) Wind: ASCE 7-
98; 120mph (3-second gust); h=25f1: TCDL=4.2psf: BCDL=S.Opsf; Category II; Exp B; partially; MWFRS interior zone; cantilever left and right exposed ; end vertical left
and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 5) Provide adequate drainage
to prevent water ponding. 6) This truss has
been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads per Table No. 16-8, UBC-94. 7) Provide mechanical connection (
by others) of truss to bearing plate capable of withstanding 1696lb uplift at joint 2 and 1437 lb uplift at joint 19. 8) Design assumes 4x2 (
flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails. 9) Special hanger(s)
or other connection device(s) shall be provided sufficient to support concentrated load(s) 1360.01b down and 662.41b up at 19-10-8, and 474.81b down and
327.61b up at 7.0-0 on bottom chord. The design/selection of such special connection device(s) Is the responsibility of others. 10) Randall Byrd, P.
E. # 23451, 2325 Jason Street ,Merritt Island, Florida 32952 (321) 453.65640 LOAD CASE(S) Standard
1) Regular. Lumber Increase=
1.25, Plate Increase=1.25 Uniform Loads (pif) Vert:
2-30=-20,
30-32=-04(F=24), 19.32=20, 1-33=54, 2-33=-14, 2-4=54, 4-11=120(F=66), 11-34=-120(1`=66), 17-34=54, 17-20=54 Concentrated Loads (lb) Vert:
30=-475(F)
32=-1360(F)
Job Truss Type Oty Ply Blagg/Blegg Residence/sec 17
MASTER T05A TB-OSSSTONHIP 1
2 Job Reference (optional)
Randall Byrd, P.E. 023451. 23235 Jason Street, Merritt Island, FI. 32952 (321) 453-6564 5.200 s Sep 30 2003 M7ek Industries, Inc. Mon Mar 29 08:36:46 2004 Page 1
14- 4-1-0 11-2-0 154-0 19-6-0 23-8-0 27-10-0 34-11-0 39-0-0 104-0
1-4-0 4-1-0 7-1-0 4-2-0 4-2-0 4-2-0 4-2-0 7-1-0
i
4-1-0 14-0
Scab " ON
us_
3s
mom
a.n 2.111
12
a.0 a.a
sn a
ae.
SJG 3 12 5.61,
n
3.. G
a..
3
2x.
u
IY
ml
410= 31 30 29 xl 77 32 Mil 25 x. 23 xx xl A10=
3.111 .E= m/= d.= 410= Ve= At= 6L= aE ll
Ve= m.=
4-1-0 11-2-0 154-0 19-6-0 23-8-0 27-10-0 34-11-0 39-0-0
4-1-0 7-1-0 4-2-0 4-2-0 4-2-0 4-2-0 7-1-0 4-1-0
Plate offsets x Y : (2:0-5-0,0-1-71,,(19:0.5.0 0-1-7j
CSI DEFL in (loc) Ude9 L/d PLATES GRIPLOADING(psQ SPACING 2-0-0
TCLL 20.0 Plates Increase 1.25 TC 0.48 Vert(LL) 0.20 26-27 >999 240 M1120 2491190
TCDL 7.0 Lumber Increase 1.25 BC 0.42 Vert(TL) -0.25 26-27 >999 180
BCLL 0.0 Rep Stress Incr NO WB 0.44 Horz(TL) 0.06 19 n/a n/a
BCDL 10.0 Code FBC20011ANS195 Matrix) Weight: 681 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.2 TOP CHORD Sheathed or 5.1-15 oc purlins. Except:
BOT CHORD 2 X 8 SYP No. 1D 3 Rows at 1/4 pts 4-17
WEBS 2 X 4 SYP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2 X 4 SYP No.2 'Except*
02 2 X 4 SYP No.3
REACTIONS (lb/size) 2=337810-8-0. 19=2605/0-8-0
Max Horz2=659(load case 5)
Max Upllft2=-1732(load case 5). 19=1401(load case 6)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-34=0/31. 2-34=0/33, 2-3=-6520/3218, 3-4=6721/3415, 4-5=-3638/1502, 5-7=3537/1521, 7-8=3652/1809, 8-11=-36422093,
11-35=34582154, 12-35=35692151, 12-14=35942082, 14-16=3537/1982, 16.17=3582/1973, 17-18=4984/2660, 18-19=-4912/2538, 19-20=0/
38, 4-6=-33512281, 6.9=-3098/1964, 9-10=-1468/752, 10-13=1468/752, 13-15=1533/878, 15-17=1642/986 BOT CHORD 2-
31=-3414/5752, 30-31--3414/5752, 29-30=-3516/5968, 28-29=3854/6514, 27-28=385416514. 27-32-3539/6262. 26.32=3539/6262, 26.33=-2278/
4697, 25-33=2278/4697, 24-25=2385/4806, 23-24=2385/4806, 22-23=-2181/4430, 21-22=2148/4324, 19-21=2148/4324 WEBS 4-30=
331/680. 17-22=24/194, 4.29=452/729, 6-29=-389/449, 6.27=-349/423, 9-27=375/903. 9-26=-2171/1583, 10.26=14952689, 13-26=15l/
333, 13.25=193/141, 15-25=163/139, 15.23=191/197, 17-23=-271/502, 3-31=-337/252, 3.30=171/339, 18-22=87/179, 18-21-231/
198.6-7=505/636, 8-9=490/642, 12-13=-185206, 14-15=239258, 10-11=-15152719 NOTES (10) 1)
2-ply
truss to be connected together with 0.131"x3" Nails as follows: Top chords connected
as follows: 2 X 4 - 1 row at D-9-0 oc. Bottom chords connected
as follows: 2 X 8 - 2 rows at 0-7-0 oc. Webs connected es
follows: 2 X 4 - 1 row at 0-9-0 oc. 2) All loads
are considered equally applied to all plies, except if noted as front (F) or back (B) face In the LOAD CASE(S) section. Ply to ply connections have been provided to
distribute only loads noted as (F) or (B), unless otherwise Indicated. 3) Unbalanced roof
live loads have been considered for this design. 4) Wind: ASCE
7-98: 120mph (3-3econd gust); h=25ft; TCDL=4.2psf; BCDL=S.Opsf; Category II; Exp B; partially; MWFRS interior zone; cantilever left and right exposed ; end vertical
left and right exposed; Lumber DOL-1.33 plate grip DOL-1.33. 5) Provide adequate
drainage to prevent water ponding. 6) This truss
has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads per Table No. 16-8, UBC-94. 7) Provide mechanical
connection (by others) of truss to bearing plate capable of withstanding 1732 lb uplift at joint 2 and 1401 lb uplift at joint 19. 8) Design assumes
4x2 (flat orientation) purlins at oc spacing Indicated, fastened to truss TC w/ 2.1 Od nails. 9) Special hanger(
s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 474.81b down and 327 61b up at 7-0-0. and 1360.01b down
and 662.41b up at 17-9-8 on bottom chord. The design/selection of such special connection device(s) is the responsibility of others. 10) Randall Byrd,
P.E. # 23451. 2325 Jason Street ,Merritt Island, Florida 32952 (321) 453.65640 LOAD CASE(S)
Standard 1) Regular. Lumber
Increase=l 25, Plate Increase=1.25 Uniform Loads (plQ
Vert: 2-30=
20. 30-33=-44(F=24), 19-33=-20, 1-34-54, 2-34-14, 2.4--54, 4-11--120(F=66), 11-35=-120(F--66), 17.35=54, 17-20=-54 Concentrated Loads (lb)
Vert: 30=475(
F) 32=1360(F)
Job Truss Truss Type Oty Ply— Blegp/ Blegg Residence/ sec 17
MASTER T06 ROOF TRUSS 21 1
Job Reference (optional)
Randall Byrd, P.E. #23451. 23235 Jason Street. Merritt Island, Fl. 32952 (321) 453-6564 5.200 s Sep 30 2003 MfTek Industries, Inc. Mon Mar 29 08-36:46 2004 Page 1
11-4-9 6-10-5 13-2-3 19-6-0 25-9-13 32-1-11 39-0-0 40-4-0
14-0 6-10-5 6-3-13 6-3-13 6-3-13 6-3-13 6-10-5 14-0
SOY • 1 M.
0
a F1
b4 b4C
3 r
b 4
as c
b J
b4
1 N,
7 10
111
3.8 13 14 10 17 3.1 =
a= h3= 3.6 No= 3.4=
10-0-4 19-6-0 28-11-12 39-0-0
10-0-4 9-5-12 9-5-12 10-0-4
Plate Offsets X Y : [2:0-4-12,0-1-8) 8:0-3.0,0.0-4] [9:0.1-7 0.0-12],[10:0-8.0,0-0-2),-[13:0.3-0.0.0-4I
DEFL in (loc) Udefl L/dLOADING(psf) SPACING 2-0-0 CSI PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.56 Vert(LL) -0 25 12-14 >999 240 M1120 249/190
TCDL 7.0 Lumber Increase 1.25 BC 0.82 Vert(TL) -0.55 12-14 >843 180
BCLL 0.0 Rep Stress Incr YES WB 0.77 Horz(TL) 0.10 10 n/a n/a
BCDL 10.0 Code FBC2001/ANSI95 Simplified) Weight: 202 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.2 TOP CHORD Sheathed or 3-6-12 oc pudins.
80T CHORD 2 X 4 SYP No.1 D BOT CHORD Rigid ceiling directly applied or 6-4-1 oc bracing. WEBS 2 X 4 SYP No.3 WEBS 1 Row at midpt 5-14, 7-14
REACTIONS (lb/size) 2=1508/0-8-0, 10=1508/0-8.0
Max Horz2=-165(load case 6)
Max Uplift2--692(load case 5), 10=-692(load case 6)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=0/16, 2-3=2445/1079, 3.4=-2212/1009, 4-5=-2212/1009, 5-6=1553f797, 8-7=1553f797, 7-8=2212/1009. 8.9=2212/1009, 9.10=-2445/1079. 10-11=0/16
80T CHORD 2-16=-987/2159, 15.16=68a/1798, 14-15=-688/1798, 13-14=-579/1798, 12-13=-579/1798, 10-12=-8222159
WEBS 3-16=-271/J33, 5-16=160/456, 5.14=59a/459, 6.14=-455/1047, 7-14=598/459, 7-12=-160/456, 9-12=271/333
NOTES (5)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-98; 120mph (3-second gust); h=25ft; TCDL=4.2psf; BCDL=5.Opsf; Category 11; Exp 8; partially; MWFRS Interior zone; cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33.
3) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrenl with any other live loads per Table No. 16-8, UBC-94.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 692 lb uplift at joint 2 and 692 lb uplift at joint 10.
5) Randall Byrd, P.E. # 23451, 2325 Jason Street ,Merritt Island, Florida 32952 (321) 453-65640
LOAD CASE(S) Standard
Job Truss Truss Type Oty Ply Blagg/Blagg Residence/sec 17
MASTER T07 MONO TRUSS 1 n
Job Reference (optional)
Randall Byrd, P.E. #23451. 23235 Jason Street, Merritt Island. FI. 32952 (321) 453-6564 5.200 s Sep 30 2003 MiTek Industries, Inc. Mon Mar 29 08:36:46 2004 Page 1
3-9-8 7-0-0
3-9-8 3-2-8
b4 II /uM • 1:1/.
3
00 12 4
2 wJ
TI
WI
cot
1
b4=
3-9-8
1
b4 II
S
tr/ _
7-0-0
3-9-8 3-2-8
LOADING(psf) SPACING 2-0-0 CSI DEFL In (loc) I/dee Ud PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.12 Vert(LL) 0.01 5 >999 240 M1120 249/190
TCDL 7.0 Lumber Increase 1.25 BC 0.33 Vert(TL) 0.01 5 >999 180
BCLL 0.0 Rep Stress Incr NO WB 0.21 Horz(TL) 0.00 4 n/a n/a
BCDL 10.0 Code FBC2001/ANS195 Simplified) Weight: 79lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.2 TOP CHORD Sheathed or 6-0-0 oc purtins, except end verticals.
BOT CHORD 2 X 6 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0.0 oc bracing. WEBS 2 X 4 SYP No.3
REACTIONS (lb/size) 1=1500/0-8-0, 4=1500/Mechanical
Max Horz1=150(load case 4)
Max Uplift1=721(load case 5). 4=740(load case 5)
FORCES (lb) - Maximum Compresslon/Maximum Tension
TOP CHORD 1-2=14937708, 2-3=38/52, 3-4 83/71
BOT CHORD 1-5=609/1316, 4-5=-609/1316
WEBS 2-5=-580/1324, 2-4=-1538f798
NOTES (7)
1) 2-ply truss to be connected together with 0.131•x3• Nails as follows:
Top chords connected as follows: 2 X 4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 2 X 6 - 2 rows at 0-9-0 oc.
Webs connected es follows: 2 X 4 - 1 row at 0-9-0 oc.
2)IAII loads are considered equally applied to all plies, except if noted as front (F) or back (B) face In the LOAD CASE(S) section. Ply to ply connections have
been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-98: 120mph (3-second gust); h=25ft; TCDL=4.2psf; BCDL=5.Opsf; Category It: Exp B; partially; MWFRS Interior zone; cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrenl with any other live loads per Table No. 16-B, UBC-94.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 721 lb uplift at joint 1 and 740 lb uplift at joint 4.
7) Randall Byrd, P.E. # 23451, 2325 Jason Street ,Merritt Island, Florida 32952 (321) 453.65640
LOAD CASE(S) Standard
1) Regular. Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-4=406(1`=386). 1-3=-54
Job Truss Truss Type Oty Ply Blagg/ Blagg Residence/ sec 17
MASTER T08 ROOF TRUSS 1 1
Job Reference o Lionel
Randall Byrd, P.E. 023451, 23235 Jason Street. Merritt Island, FI. 32952 (321) 453-6564 5.200 s Sep 30 2003 M.Tek Industries, Inc. Mon Mar 29 08:36:47 2004 Pagel
1-4-0 3-9-4 7-0-0 10-8-0 14-4-0 17-6-12 21-4-0 22-8-0
1-4-0 3-9-4 3-2-12 3-8-0 3-8-0 3-2-12 3-9-4 1-4-0
8c • 136
410 =
A. 11 b10=
S
6W 12 L.4
3.4
W
2
1. 12 12 11 10Ao =
a. li 3.4 it o 1. = h = a.n
3-9-4 7-0-0 10-8-0 14-4-0 17-6-12 21-4-0
3-9-4 3.2-12 3-8-0 3-8-0 3-2-12 3-9-4
Plate Offsets X Y : [2.0-8-0 0-0-6],[4:0-7-0,0-2-0),[6:0-7-0,0.2-0)_[8:0-8-0.0.0-61,-[10.0.2-0,0.0.121 [12:0-4-0,0-3-0]
LOADING(pso SPACING 2-0-0 CSI DEFL in (loc) Udefl Ud PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.57 Vert(LL) 014 12 >999 240 M1120 249/190TCDL70LumberIncrease1.25 BC 0.60 Vert(Q -0.18 11-12 >999 180
BCLL 00 Rep Stress Inu NO WB 0.21 Horz(TL) 0.07 6 n/a n/a
BCDL 100 Code FBC2001/ANSI95 Simplified) Weight: 114 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.2 TOP CHORD Sheathed or 3-4-13 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 5-5-5 oc bracing. WEBS 2 X 4 SYP No.3
REACTIONS (lb/size) 2=1620/0.8-0, 8=1620/0-8-0
Max Horz2=-77(load case 6)
Max Uplift2=914(load case 5), 8=-914(load case 6)
FORCES (Ib) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=0/16, 2-3--2873/1569, 3-4=2696/1566, 4-5=-2718/1594, 5.6=2716/1594, 6-7=2696/1566, 7-8=-2873/1569, 8-9=0/16
BOT CHORD 2.14=-1356/2507, 13.14=-1356/2507, 12-13=-1324/2435, 11-12=1281/2435. 10.11=1309/2507.8-10=1309/2507
WEBS 3.14=0/136, 3-13=118/97.4-13=322/641, 4-12=-264/455, 5.12=-400/398, 6.12=-264/455, 6.11=322/641. 7-11=118/97, 7-10=0/136
NOTES (9)
1) Unbalanced roof live loads have been considered for this design.
2) Wlnd: ASCE 7-98, 120mph (3-second gust); h-25ft; TCDL=4.2psf; BCDL-5 Opsf; Category 11; Exp B: partially; MWFRS interior zone; cantilever left and right
exposed ; end vertical left and right exposed: Lumber DOL=1.33 plate grip DOL=1.33.
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads per Table No. 16-B, UBC-94.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 914 lb uplift at joint 2 and 914 lb uplift at joint 8.
6) Girder carries hip end with 7-0-0 end setback
7) Special hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 474 Bib down and 327.61b up at 14 4 0, and
474 81b down and 327.61b up at 7-0-0 on bottom chord. The design/selection of such special connection device(s) is the responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (8).
9) Randall Byrd, P.E. 0 23451. 2325 Jason Street ,Merritt Island, Florida 32952 (321) 453-65640
LOAD CASE(S) Standard
1) Regular. Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plo
Vert: 14=54, 4-6=113(F-58), 6-9=54, 2-13=-20, 11-13=-42(F=22), 8-11-20
Concentrated Loads (lb)
Vert:13=-475(F) 11=-475(F)
Job Truss
I
Truss Type Oty PlyBlagg/ Blegg Residence/ sec 17
MASTER T09 ROOF TRUSS 1 1
Job Reference tional
Randall Byrd, P.E. 023451. 23235 Jason Street, Merritt Island, FI. 32952 (321) 453-6564 5.200 s Sep 30 2003 M9stries, Inc. Mon Mar 29 08:36:47 2004 Page 1Indu
1-4-0 4-9-4 9-0-0 12-4-0 16-6-12 21-4-0 22.8-0
1-4-0 4-9-4 4-2-12 3-4-0 4-2-12 4-9-4 1-4-0
s
6mri'F b.o
b.L
0
w
2 r
to
h4=
a.=
a= a1= a.=
9-0-0 124-0 214-0
9-0-0 3-4-0 9-0-0
Plate Offsets X 5:0.7-0 0-2-0
LOADING(psQ SPACING 2.0-0 CSI DEFL In (Ioc) Udefl Ud PLATES GRIPTCLL20.0 Plates Increase 1.25 TC 0.28 Vert(LL) -0.15 7-9 >999 240 M1120 249/190TCDL7.0 Lumber Increase 1.25 BC 0.66 Vert(TL) -0.31 7-9 >801 180
BCLL 0.0 Rep Stress Incr YES WB 0.10 Horz(rL) 0.03 7 n/a n/a
BCDL 10.0 Code FBC2001/ANSI95 Simplified) Weight: 106lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.2 TOP CHORD Sheathed or 5-8-6 oc purlins. BOT CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or B-10.6 oc bracing. WEBS 2 X 4 SYP No.3
REACTIONS (lb/size) 2-855/0-8-0, 7=855/0.8-0
Max Horz2=91(load case 5)
Max Uplift2=403(load case 5). 7-403(load case 6)
FORCES 6b) - Maximum Compression/Maximum Tenslon
TOP CHORD 1-2=0/16, 2-3=1168/546. 3-4=940/410, 4-5=-647/428, 5.6=-940/410, 6-7=116a/546, 7-8=0/16
BOT CHORD 2-11--468/1024, 10-11=211/847, 9-10=211/847, 7-9=377/1024
WEBS 3-11=213/265, 4-11=57/253, 5.11--89/89, 5-9=-62/253, 6-9=-213/265
NOTES (6)
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-98; 120mph (3-second gust); h=25ff; TCDL-4.2psf; BCDL=S Opsf; Category Il; Exp B; partially; MWFRS Interior zone; cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33.
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads per Table No. 16-8, UBC-94.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 403 lb uplift at joint 2 and 403 lb uplift at joint 7.
6) Randall Byrd, P.E. 9 23451. 2325 Jason Street ,Merritt Island, Florida 32952 (321) 453.65640
LOAD CASE(S) Standard
Job Truss Type City Ply Blagg/Blagg Residence/ sec 17
MASTER T10 TRUSST 8 1
Job Reference (optional)
Randall Byrd, P.E. #23451. 23235 Jason Street, Merritt Island, FI. 32952 (321) 453-6564 5.200 s Sep 30 2003 MiTek Industries, Inc. Mon Mar 29 08:36:47 2004 Page 1
14-0 5-7-4 10-8-0 15-8-12 21-4-0 22-8-0
1-4-0 5-7-4 5-0-12 5-0-12 5-7-4 1-4-0
3f • 1.38
tre =
900 F12 h.
a.o
0 s
e
TTF-
1
10
a.=
7-3-8 14-0-8 21-4-0
7-3-8 6-9-0 7-3-8
Plate Offsets X,v : 5,0-1-120-0-12 _[6:0.1-4,0-0-z LOADING(
psp SPACING 2-0-0 CSI DEFL in (loc) Vdefl L/d PLATES GRIP TCLL
20.0 Plates Increase 1.25 TC 0.36 Vert(LL) -0.07 8.10 >999 240 M1120 249/190 TCDL
7.0 Lumber Increase 1.25 BC 0.54 Vert(TL) -0.16 B-10 >999 180 BCLL
0.0 Rep Stress Incr YES WB 0.13 Horz(TL) 0.03 6 n/a n/a BCDL
10.0 Code FBC2001/ANS195 Simplified) Weight: 99lb LUMBER
BRACING TOP
CHORD 2 X 4 SYP No.2 TOP CHORD Sheathed or 5-7-0 oc purlins. BOT
CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 9-3-9 oc bracing WEBS2X4SYPNo3REACTIONS (
lb/size) 2=855/0-8-0. 6=855/0.8-0 Max
Horz2=-103(load case 6) Max
Uplift2=-413(load case 5). 6=-413(load case 6) FORCES (
lb) - Maximum Compression/Maximum Tension TOP
CHORD 1-2=0/16, 2-3=-1169/509, 3-4=1022/507, 4-5=1022/507, 56=1169/509, 6-7=0/16 BOT
CHORD 2-10=-437/1029, 9-10=199!/14, 8-9=-199/714, 6-8=-351/1029 WEBS
3-10=-221/264, 4-10=182/383, 4-8=-182/383, 5-8=-221/264 NOTES (
5) 1)
Unbalanced roof live loads have been considered for this design. 2)
Wind: ASCE 7-98; 120mph (3-second gust); h=25tt; TCDL=4.2psf, BCDL=S.Opsf; Category II, Exp B; partially; MWFRS Interior zone; cantilever left and right exposed ;
end vertical left and right exposed; Lumber DOL=1 33 plate grip DOL=1.33. 3)
This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other Irve loads per Table No. 16-8, UBC-94. 4)
Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 413lb uplift at joint 2 and 413 lb uplift at joint 6. 5)
Randall Byrd, P.E. 0 23451, 2325 Jason Street ,Merritt Island, Florida 32952 (321) 453-65640 LOAD
CASE(S) Standard
Job Truss Truss Type Oty Ply Blagg/ Blagg Residence/ sec 17
MASTER T11 ROOF TRUSS 3 1
Job Reference (optional)
Randall Byrd, P E #23451, 23235 Jason Street, Merritt Island, FI. 32952 (321) 453-6564 5.200 s Sep 30 2003 MiTek Industries, Inc. Mon Mar 29 08:36:48 2004 Page 1
1-4-0 5-7.4 10-8-0 15-8-12 21-4-0
1-4-0 5-7-4 5-0-12
m =
5-0-12 5-7-4
ioM • 136,
4OOr{ h4P
3
1
a4 5
3
1
Y
4 L4=
7
Al= h4_
7-3-8 14-0-8 21-4-0
7-3-8 6-9-0 7-3-8
Plate Offsets Y . 2.0-1-4,0-0.215:0-1-12 0-0-12 LOADING(
psf) SPACING 24)-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL
20.0 Plates Increase 1.25 TC 0.36 Vert(LL) -0.07 7-9 >999 240 M1120 249/190 TCDL
7.0 Lumber Increase 1.25 BC 0.57 Vert(TL) -0.16 7-9 >999 180 BCLL
0.0 Rep Stress Incr YES WB 0.14 Horz(TL) 0.03 6 n/a n/a BCDL
10.0 Code FBC2001/ANS195 Simplified) Weight. 97 lb LUMBER
BRACING TOP
CHORD 2 X 4 SYP No.2 TOP CHORD Sheathed or 5-5-14 oc purtins BOT
CHORD 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 9-1-12 oc bracing. WEBS
2 X 4 SYP No.3 REACTIONS (
lb/size) 6=772/Mechanical, 2=862/0-8-0 Max
Horz2=113(load case 5) Max
Uplif16=-330(load case 6). 2=-415(load case 5) FORCES (
lb) - Maximum Compression/Maximum Tension TOP
CHORD 1-2=0/16, 2-3=-1184/514, 3-4=1037/512, 4-5=1051/519, 5-6=-1202/524 BOT
CHORD 2.9=-452/1042, 8-9=-214/728, 7.8=-214/728, 6-7=389/1066 WEBS
3.9=-221/264, 4-9=-182/382, 4-7=192/403, 5-7=-239/275 NOTES (
6) 1)
Unbalanced roof live loads have been considered for this design. 2)
Wind: ASCE 7-98; 120mph (3-second gust); h=25ft; TCDL=4.2psf; BCDL=5.Opsf, Category 11; Exp B; partially; MWFRS lnlenor zone; cantilever left and right exposed;
end vertical left and right exposed; Lumber DOL=1 33 plate grip DOL=1.33. 3)
This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads per Table No. 16-B, UBC-94 4)
Refer to girder(s) for truss to truss connections. 5)
Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 330 lb uplift at joint 6 and 415 lb uplift at joint 2. 6)
Randall Byrd, P.E. # 23451. 2325 Jason Street ,Merritt Island, Florida 32952 (321) 453-6564 LOAD
CASE(S) Standard
Job Truss Truss Type Oty Ply 9 Residence/sec 17
MASTER' T12 MONO TRUSS 1 BlagRg/eafelarence(optional)
Randall Byrd, P.E. 023451. 23235 Jason Street, Merritt Island, Fl. 32952 (321) 453-6564 5.200 s Sep 30 2003 MiTek Industries. Inc. Mon Mar 29 08:36-48 2004 Page 1
3-9-8 7-0-0
3-9-8 3-2-8
21411 OcaM • 1.1
400 r1{ a44
2 yy
T1
W va
1
1
b411
s 4
3-9-8 7-0-0
3-9-8 3-2-8
LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/dell Ud PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.11 Vert(LL) 001 5 >999 240 M1120 249/190
TCDL 70 Lumber Increase 1.25 BC 0.30 Vert(TL) 001 5 >999 180
BCLL 0.0 Rep Stress Incr NO WB 0.19 Horz(TL) 0.00 4 n/a rile
BCDL 10.0 Code FBC2001/ANSI95 Simplified) Weight: 79lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.2 TOP CHORD Sheathed or 6-0-0 oc purtins, except end verticals.
BOT CHORD 2 X 6 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10.0-0 oc braclng. WEBS 2 X 4 SYP No.3
REACTIONS (lb/size) 1=1360/0-8-0, 4=1360/Mechanical
Max Horz1=150(load case 4)
Max Upfiftl=-653(load case 5). 4=671(load case 5)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=-1353/640, 2-3=38/52, 3-4=-83f71
BOT CHORD 1-5=549/1193, 4-5=549/1193
WEBS 2.5=512/1184, 2-4=1394l728
NOTES (7)
1) 2-ply truss to be connected together with 0.131•x3• Nails as follows:
Top chords connected as follows: 2 X 4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 2 X 6 - 2 rows at 0-9-0 oc.
Webs connected as follows: 2 X 4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section Ply to ply connections have
been provided to distribute only loads noted as (F) or (B), unless otherwise Indicated.
3) Wind: ASCE 7.98. 120mph (3-second gust); h=25ft; TCDL=4.2psf; BCDL=S.Opsf; Category 11; Exp B; partially; MWFRS Interior zone; cantilever left and right
exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL-1.33.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads per Table No. 16-B. UBC-94.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 653 lb uplift at joint 1 and 671 lb uplift at joint 4.
7) Randall Byrd, P.E. 0 23451. 2325 Jason Street ,Merritt Island, Florida 32952 (321) 453-65640
LOAD CASE(S) Standard
1) Regular: Lumber Increase=1.25. Plate Increase=1.25
Uniform Loads (plo
Veil: 1-4=-363(F=-343), 1.3=54
FORM 60OA-2001
WATER HEATING & CODE COMPLIANCE STATUS
Residential Whole Building Performance Method A - Details
I ADDRESS: , , , PERMIT #: I
BASE AS -BUILT
WATER HEATING
Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total
Bedrooms Volume Bedrooms Ratio Multiplier
3 2564.00 7692.0 50.0 0.95 3 1.00 2375.07 1.00 7125.2
As-BuiR Total: 7125.2
CODE COMPLIANCE STATUS
BASE AS -BUILT
Cooling + Heating +
Points Points
Hot Water
Points
Total
Points
Cooling
Points
Heating + Hot Water = Total
Points Points Points
17767 4024 7692 29483 10949 4608 7125 22682
PASS nn, va
EnergyGaugeT"
DCA
Form 600A-2001 EnergyGauge9/FIaRES'2001 FLRCSB J3.22
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE SCORE* = 87.8
The higher the score, the more efficient the home.
i . New construction or existing New _ 12. Cooling systems
2. Single family or multi -family Single family _ a. Central Unit Cap: 38.9 kBtu/hr _
3. Number of units, if multi -family 1 _ SEER: 12.00 _
4. Number of Bedrooms 3 _ b. N/A
5. is this a worst case? No
6. Conditioned floor area (Rl) 2105 ft' c. N/A
7. Glass area & type
a. Clear - single pane 186.0 ft' _ 13. Heating systems
b. Clear - double pane R0.0 ' _ a. Electric Heat Pump Cap: 36.0 kBtu/hr _
c. Tint/other SHGC - single pane 0.0 R' _ HSPF: 7.90 _
d. Tint/other SHGC - double pane 0.0 ft' b. N/A
8. Floor types
a. Slab -On -Grade Edge Insulation R=0.0, 194.0(p) R _ c. N/A
b. N/A
c. N/A 14. Hot water systems
9. Wall types a. Electric Resistance Cap: 50.0 gallons _
a. Concrete, int Insul, Exterior R=4.0, 1667.0 ft' _ EF: 0.95 _
b. Frame, Wood, Adjacent R=11.0, 168.0 R' _ b. N/A
c. N/A
d. N/A c. Conservation credits
e. N/A I R-Heat recovery, Solar
10. Ceiling types DHP-Dedicated heat pump)
a. Under Attic R=30.0, 2105.0 R' _ 15. HVAC credits PT, _
b. N/A CF-Ceiling fan, CV -Cross ventilation,
c. N/A HF-Whole house fan,
11. Ducts PT -Programmable Thermostat,
a. Sup: Unc. Ret: Unc. AH: Interior Sup. R=6.0, 45.0 R _ MZ-C-Multizone cooling,
b. N/A MZ-H-Multizone heating)
I certify that this home has complied with the Florida Energy Efficiency Code For Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
VOTE.- The home's estimated energy performance score is only available through the FLARES computer program.
This is not a Building Energy Rating. Ifyour score is 80 or greater (or 86 for a US EPA/DOE EnergyS dW designation),
your home may qualify for energy efciency mortgage (EEM) incentives ifyou obtain a Florida Energy Gauge Rating.
Contact the Energy Gauge Hotline at 3211638-1492 or see the Energy Gauge web site at wwwfsec. ucf edu for
information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction,
contact the Department of Community Affairs at 8501487-1824.
EnergyGauge® (Version: FLRCSB v3.22)
FORM 60OA-2001
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
Residential Whole Building Performance Method A
Project Name: blagg2 Builder.
Address: Permitting Office:
City, State: Permit Number.
Owner. Jurisdiction Number:
Climate Zone: Central
I . New construction or existing New _ 12. Cooling systems
2. Single family or multi -family milSinglefay _ a. Central Unit Cap: 38.9 kBtu/hr _
3. Number of units, if multi -family 1 _ SEER: 12.00
4. Number of Bedrooms 3 _ b. N/A
5. is this a worst case? No
6. Conditioned floor area (ft 2105 ft' c. N/A
7. Glass area & type
a. Clear - single pane 186.0 ft' _ 13. Heating systems
b. Clear - double pane 0.0 fl' _ a. Electric Heat Pump Cap: 36.0 kBtu/hr _
c. Tint/other SHGC - single pane 0.0 fl7 _ HSPF: 7.90 _
d. Tint/other SHGC - double pane 0.0 fl' b. N/A
8. Floor types
EL Slab -On -Grade Edge Insulation R=0.0, 194.0(p) 11 _ c. N/A
b. N/A
c. N/A 14. Hot water systems
9. Wall types a. Electric Resistance Cap: 50.0 gallons _
a. Concrete, Int Insul, Exterior R=4.0, 1667.0 fl' _ EF: 0.95 _
b. Frame, Wood, Adjacent R=1 1.0, 168.0 fl= _ b. N/A
c. N/A
d. N/A c. Conservation credits
e. N/A HR-Heat recovery, Solar
10. Ceiling types DHP-Dedicated heat pump)
a. Under Attic R=30.0, 2105.0 ft' _ 15. HVAC credits PT, _
b. N/A CF-Ceiling fan, CV -Cross ventilation,
c. N/A HF-Whole house fan,
11. Ducts PT -Programmable Thermostat,
a. Sup: Unc. Ret: Unc. AH: Interior Sup. R=6.0, 45.0 It _ W-C-Multizone cooling,
b. N/A MZ-H-Multizone heating)
Glass/Floor Area: 0.09 Total as -built points: 22682 PASSTotalbasepoints: 29483
I hereby certify that the plans and specifications covered
by this calculation are in compliance with the Florida
Energy Code.
PREPARED BY: Clark Waters
DATE: S
1 hereby certify that this building, as designed, is in
compliance with the Florid n C
OWNER/AGENT:
DATE: -,9-7
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
BUILDING OFFICIAL:
DATE:
EnergyGauge® (Version: FLRCSB v3.22)
FORM 60OA-2001
Code Compliance Checklist
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT #:
6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST
COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK
Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 afm/s .ft. window area; .5 cfm/ .ft. door area.
Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall:
foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility
penetrations: between wall panels & top/bottom plates; between walls and floor.
EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends
from and is sealed to the foundation to the top plate.
Floors 606.1ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members.
EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed
to the perimeter, pen"ions and seams.
Ceilings 606.1 ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor, around shafts, chases,
soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate;
attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is
installed that is sealed at the perimeter, at penetrations and seams.
Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a
sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from
conditioned space, tested.
Mufti -story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors.
Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA,
have combustion air.
6A-22 OTHER PRESCRIPTIVE MEASURES Imust be met or exceeded by all residences-)
COMPONENTS SECTION REQUIREMENTS CHECK
Water Heaters 612.1 Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit
breaker electric or cutoff as must be provided. External or built-in heat trap required.
Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools
must have a pump timer. Gas spa & pod heaters must have a minimum thermal
efficiency of 78%.
Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG.
Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically
attached, sealed, insulated, and installed in accordance with the criteria of Section 610.
Ducts in unconditioned attics: R-6 min. insulation.
HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system.
Insulation 604.1, 602.1 Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides.
Common ceiling & floors R-11.
EnergyGaugeT" DCA Form 60OA-2001 EnergyGauge&/FlaRES'2001 FLRCSB J3.22
FORM 60OA-2001
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT *
BASE AS -BUILT
Winter Base Points: 6414.3 Winter As -Built Points: 9759.9
Total Winter X System = Heating Total X Cap X Duct X System X Credit Heating
Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points
DM x DSM x AHU)
6414.3 0.6274 4024.3
9759.9
9759.9
1.000
1.00
1.078 x 1.160 x 0.92) 0.432
1.150 0.432
0.950
0.950
4608.3
4608.3
EnergyGaugeTM DCA Form 60OA-2001 EnergyGaugeOIFIaRES'2001 FLRCSB J3.22
FORM 60OA-2001
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT #:
BASE AS -BUILT
GLASS TYPES
18 X Conditioned X BWPM = Points Overhang
Floor Area Type/SC Omt Len Hgt Area X WPM X WOF = Point
18 2105.0 5.86 2220.4 Single, Clear S 12.0 2.0 36.0 7.73 2.29 637.5
Single, Clear E 1.5 2.0 42.0 9.96 1.11 466.3
Single, Clear N 1.5 2.0 48.0 12.32 0.99 586.2
Single, Clear W 1.5 2.0 60.0 10.74 1.07 689.5
As -Built Total: 186.0 2379.5
WALL TYPES Area X BWPM Points Type R-Value Area X WPM = Points
Adjacent 168.0 1.80 302.4 Concrete, Int Insul, Exterior 4.0 1667.0 3.35 5584.4
Exterior 1667.0 2.00 3334.0 Frame, Wood, Adjacent 11.0 168.0 1.80 302.4
Base Total: 183S.0 3636.4 As -Built Total: 1835.0 5886.8
DOOR TYPES Area X BWPM Points Type Area X WPM = Points
Adjacent 0.0 0.00 0.0 Exterior Wood 33.0 7.60 250.8
Exterior 33.0 5.10 168.3
Base Total: 33.0 168.3 As -Built Total: 33.0 250.8
CEILING TYPESArea X BWPM Points Type R-Value Area X WPM X WCM = Points
Under Attic 2105.0 0.64 1347.2 Under Attic 30.0 2105.0 0.64 X 1.00 1347.2
Base Total: 2105.0 1347.2 As -Built Total: 2105.0 1347.2
FLOOR TYPES Area X BWPM Points Type R-Value Area X WPM = Points
Slab 194.0(p) 1.9 368.6 Slab -On -Grade Edge Insulation 0.0 194.0(p 2.50 485.0
Raised 0.0 0.00 0.0
Base Total: 368.6 As -Built Total: 194.0 485.0
INFILTRATION Area X BWPM Points Area X WPM = Points
2105.0 0.28 589.4 2105.0 -0.28 589.4
EnergyGauge® DCA Form 60OA-2001 EnergyGauge®/FlaRES'2001 FLRCSB J3.22
FORM 60OA-2001
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT #:
BASE AS -BUILT
Summer Base Points: 41648.3 Summer As -Built Points: 36049.9
Total Summer X System Cooling Total X Cap X Duct X System X Credit Cooling
Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points
DM x DSM x AHU)
36049.9 1.000 1.087 x 1.150 x 0.90) 0.284 0.950 10948.9
41648.3 0.4266 17767.2 36049.9 1.00 1.125 0.284 0.950 10948.9
EnergyGaugeTM DCA Form 60OA-2001 EnergyGaugeDIFIaRES'2001 FLRCSB W3.22
FORM 60OA-2001
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT #:
BASE AS -BUILTFGLASSPESditionedXBSPM = Points Overhang
or Area Type/SC Omt Len Hgt Area X SPM X SOF Points
18 2105.0 25.78 9768.0 Single, Clear S 12.0 2.0 36.0 44.66 0.48 764.0
Single, Clear E 1.5 2.0 42.0 59.31 0.61 1509.3
Single, Clear1 N 1.5 2.0 48.0 27.96 0.77 1029.5
Single, Clear W 1.5 2.0 60.0 53.47 0.62 1973.8
As -Built Total: 186.0 5276.7
WALL TYPES Area X BSPM Points Type R-Value Area X SPM Points
Adjacent 168.0 0.70 117.6 Concrete, Int Insul, E)derior 4.0 1667.0 1.20 2000.4
E)derior 1667.0 1.90 3167.3 Frame, Wood, Adjacent 11.0 168.0 0.70 117.E
Base Total: 1835.0 3284.9 As -Built Total: 1835.0 2118.0
DOOR TYPES Area X BSPM Points Type Area X SPM Points
Adjacent 0.0 0.00 0.0 E)derior Wood 33.0 7.20 237.6
E)derior 33.0 4.80 158.4
Base Total: 33.0 168.4 As -Built Total: 33.0 237.6
CEILING TYPES Area X BSPM Points Type R-Value Area X SPM X SCM = Points
Under Attic 2105.0 2.13 4483.7 Under Attic 30.0 2105.0 2.13 X 1.00 4483.7
Base Total: 2105.0 4483.7 As -Built Total: 2105.0 4483.7
FLOOR TYPES Area X BSPM Points Type R-Value Area X SPM Points
Slab 194.0(p) 31.8 6169.2 Slab -On -Grade Edge Insulation 0.0 194.0(p 31.90 6188.6
Raised 0.0 0.00 0.0
Base Total: 6169.2 As -Built Total: 194.0 6188.6
INFILTRATION Area X BSPM Points 1 Area X SPM Points
2105.0 14.31 30122.E 2105.0 14.31 30122.6
EnergyGauge® DCA Form 600A-2001 EnergyGaugeg/FlaRES'2001 FLRCSB J.3.22
RIGHT,J WORKSHEET
Entire House
E. C. Waters Inc.
1405 N. Forest Ave., Orlando, FI 32803 Phone: 407-894-5989 Fax 999-555-2121
J: /tn to.
1 Name of room Entire House Blagg14MANUAL2Lengthofeosedwall2105ft 2105 ft
3 Room dimensions 0.0 x 0.0 ft
Ceiings Condit Option 8.0 ft Id 8.0 ft heat/cool
TYPE OF C HTM Area Load (Btuh) Area Load (Btuh) Area Area
EXPOSURE NO. Htg Clg fl2) Htg Clg OF) Htg I Clg Htg Clg Htg I Clg
5 Gross a 14B 4.0 2.1 16672 16672
Exposed b 13N 2.6 0.9 168 168
walls and c 0.0 0.0 0 0
partitions d 0.0 0.0 0 0
e 0.0 0.0 0 0
f 0.0 0.0 0 0
6 Windows and a 113 29.3 186 5442 186 5442
glass doors b 0.0 0 0 0 0
Heating c 0.0 0 0 0 0
d 0.0 0 0 0 0
e 0.0 0 0- 0 0
f 0.0 0 0 0 0
7 Windows and North 29.4 126 3704 126 3704
glass doors NE/NW 0.0 0 0 0 0
Coding E!W 87.4 60 5244 60 5244
SE/SW 0.0 0 0 0 0
South 0.0 0 0 0 0
Horz 0.0 0 0 0 0
8 Other doors a 10D 12.9 9.9 33 425 328 33 425 328
1 b 0.0 0.0 0 0 0 0 0 0
c 0.0 0.0 0 0 0 0 0 0
9 Net a 14B 4.0 2.1 16453 66338 33880 16453 66338 33880
exposed b 13N 2.6 0.9 168 435 157 168 435 157
walls and c 0.0 0.0 0 0 0 0 0 0
partitions d 0.0 0.0 0 0 0 0 0 0
e 0.0 0.0 0 0 0 0 0 0
f 0.0 0.0 0 0 0 01 0 0
10 Ceilings a 16G 0.9 1.4 2105 1945 2918 2105 1945 2918
b 0.0 0.0 0 0 0 0 0 0
c 0.0 0.0 0 0 0 0 0 0
d 0.0 0.0 0 0 0 0 0 0
e 0.0 0.0 0 0 0 0 0 0
f 0.0 0.0 0 0 0 0 0 0
11 Floors a 22A 22.7 0.0 194 4400 0 194 4400 0
Note: room b 0.0 0.0 0 0 0 0 0 0
perimeter c 0.0 0.0 0 0 0 0 0 0
is displ. d 0.0 0.0 0 0 0 0 0 0
for slab a 0.0 0.0 0 0 0 0 0 0
floors) f 0.0 0.0 0 0 0 0 0 0
12 Infiltration a 0.0 0.0 219 0 01 219 0 0
13 Subtotal loss=6+8. +11+12 78986 78986
Less external heating 0 0
Less transfer 0 0
14 Duct loss 5 OA 3949 50A 3949
15 Total loss = 13+14 82936 82936
16 Int. gains: People @ 300 0 0 0 0
Appl. @ 1200 0 0 0 0
17 Subtot RSH gain=7+8..+12+16 46231 46231
Less external cooling 0 0
Less transfer 0 0
18 Dud gain 100/ 4623 10° 4623 ry
19 Total RSH gain=(17+18)•PLF 1.00 50854 1.00 50854
20 Air required (cfm) 2719 V19 27191 27191••••I I••'•
Printout certified by ACCA to meet all requirements of Manual J 7th Ed.
wr gl-tsoR Right-Sufte Residential^' 5.0.28 RSR21331 2004-Mar-18 17:01:55
wry Projectissr Pagel
RIGHT-J WINDOW DATA
E. C. Waters Inc.
1405 N. Forest Ave.. Ortando. FI 328M Phone: 407.894-5989 Fax 999-555-2121
W S D W G L S S O N A S O O W C W S
N K I A L O T H V G N H V V H H N H
D Y R L A W R A H L G C R R G T A A
W L Z E M D G Z L O X Y T M R R
Blagg
a n s a c n 0 n 1 1 90 1.0 8.0 2.0 1.0 46.4 36.0 36.0
a n e a c n 0 n 1 1 90 1.0 17.0 2.0 1.0 87.4 42.0 42.0
a n n a c n 0 n 1 1 90 1.0 1.6 2.0 1.0 29.4 48.0 0.0
a n w a c n 0 n 1 1 90 1.0 1.6 2.0 1.0 87.4 60.0 0.0
Wnght50ft R4MSulte Residential^' 5.0.28 RSR21331 2004-Mar-18 17:01:55
47&R,*dt.rsr, Pape 1
RIGHT-J LOAD AND EQUIPMENT SUMMARY
Entire House
E. C. Waters Inc.
1405 N. Forest Ave., Orlando, FI 32803 Phone: 407-894-5989 Fax 999-55 2121
0 0
For. Jim Blagg
Notes:
Design=InfoIrma tion-
Weather Orlando, FL, US
Winter Design Conditions
Outside db 42 OF
Inside db 70 OF
Design TD 28 OF
Heating Summary
Building heat loss 82936 Btuh
Ventilation air 59 cfm
Ventilation air loss 1825 Btuh
Design heat load 84760 Btuh
Infiltration
Method Simplified
Construction quality Average
Fireplaces 0
Area ftHeating
Cooling Volume (
ft) 0 0 Air
changes/hour 1.2 0.5 Equiv.
AVF (cfm) 0 0 Heating
Equipment Summary Make
trane Trade
Efficiency
Heating
Input Heating
output Heating
temp rise Actual
heating fan Heating
air flow factor Space
thermostat 7.
9 HSPF 0
Btuh 0
Btuh 0
OF 2719
ctm 0.
033 ctm/Btuh Summer
Design Conditions Outside
db 93 OF Inside
db 75 OF Design
TD 18 OF Daily
range Relative
humidity M
50 %
Moisture
difference 43 gr/lb Sensible
Cooling Equipment Load Sizing Stricture
50854 Btuh Ventilation
0 Btuh Design
temperature swing 3.0 OF Use
mfg. data n Ratelswing
multiplier 0.98 Total
sens. equip. load 49837 Btuh Latent
Cooling Equipment Load Sizing Internal
gains 0 Btuh Ventilation
0 Btuh Infiltration
0 Btuh Total
latent equip. load 0 Btuh Total
equipment load 49837 Btuh Cooling
Equipment Summary Make
trane Trade
Efficiency
12.0 EER Sensible
cooling 0 Btuh Latent
cooling 0 Btuh Total
cooling 0 Btuh Actual
cooling fan 2719 cfm Cooling
air flow factor 0.053 cfm/Btuh Load
sensible heat ratio 100 % Printout
certified by ACCA to meet all requirements of Manual J 7th Ed. wlrrghtsoft
RIWSuite Residential" 5.0.28 RSR21331 2004-Mar-18 17:01:55 Projectl.
rsr Page 1
RIGHT-J CALCULATION PROCEDURES A, B, C, D
Entire House
I
E. C. Waters Inc.
1405 N. Forest Ave., Orlando, FI 32803 Phone: 407494-5989 Fax 999- i55-2121
Procedure A - Winter Infiltration HTM Calculation*
1. Winter infiltration AVF
1.2 ach x 0
2. Winter infiltration load
1.1 x0 cfm
3. Winter infiltration HTM
0 Btuh / 219
ftz 0.0167 = x
28 OF Winter TD = ft2
Total window = and
door area Procedure
B - Summer Infiltration HTM Calculation 0
cfm 0
Btuh 0.
0 Btuh/ft2 1.
Summer infiltration AVF 0.
5 ach x 0 ft z 0.0167 = 0 cfm 2.
Summer infiltration load 1.
1 x0 cfm x 18 OF Summer TD = 0 Btuh 3.
Summer infiltration HTM 0
Btuh / 219 ft2 Total window = 0.0 Btuh/ft2 and
door area Procedure
C - Latent Infiltration Gain 0.
68 x43 gr/Ib moist.diff. x 0 cfm = 0 Btuh erocedure
u - taumment 5itzma Loads 1.
Sensible sizing load Sensible
ventilation load 1.
1 x 0 drn vent. x 18 OF Summer TD = Sensible
load for structure (Line 19) + Sum
of ventilation and structure loads = Rating
and temperature swing multiplier x Equipment
sizing load - sensible = 2.
Latent sizing load Latent
ventilation load 0.
68 x 0 cfm vent. x 43 gr/Ib moist.diff. Internal
loads = 230 Btuh x 0 people Infiltration
load from Procedure C Equipment
sizing load - latent Construction
Quality is: a 0
Btuh 50854
Btuh 50854
Btuh 0.
98 49837
Btuh No.
of Fireplaces is: 0 0
Btuh 0
Btuh 0
Btuh 0
Btuh Printout
certified by ACCA to meet all requirements of Manual J 7th Ed. wrPghtsoft
RightSuile Residerdial- 5.0.28 RSR21331 2004-Mar-18 17:01:55 Projectl.
rsr Page 1
181
A/G LAyo L) ,r
I-tUtKAL tMtKlitNUY MANAUt:MtNI AUt:NUY O.M.B. No. 3067-0077
NATIONAL FLOOD INSURANCE PROGRAM Expires December 31, 2005
ELEVATION CERTIFICATE
Important: Read the instructions on pages 1 - 7.
SECTION A - PROPERTY OWNER INFORMATION For Insurance Canpany Use:
BUILDING OWNER'S NAME Policy Number
James and Paula Blagg
BUILDING STREET ADDRESS (Including Apt., Unit, Suite, and/or Bldg. No.) OR P.O. ROUTE AND BOX NO. Company NAIC Number 613
212 W. 20"' Street
CITY STATE ZIP CODE
SANFORD FL 32772
PROPERTY DESCRIPTION (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.)
LOT 142, SANFORD HEIGHTS ADDITION, PLAT BOOK 2, PAGE 62 SEMINOLE COUNTY
BUILDING USE (e.g., Residential, Non-residential, Addition, Accessory, etc. Use a Comments area, if necessary.)
RESIDENTIAL
LATITUDE/LONGITUDE (OPTIONAL) HORIZONTAL DATUM: SOURCE: C3 GPS (Type):
or ##.#####) NAD 1927 NAD 1983 USGS Quad Map Other. O
SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION
B1. NFIP COMMUNITY NAME & COMMUNITY NUMBER 82 COUNTY NAME B3. STATE
CITY OF SANFORD 120294 1 SEMINOLE I FLORIDA
B4. MAP AND PANEL 87. FIRM PANEL 89. BASE FLOOD ELEVATION(S)
NUMBER 85. SUFFIX B6. FIRM INDEX DATE EFFECTIVE/REVISED DATE B8. FLOOD ZONE(S) Zone AO, use depth of fbodirg)
12117CO045 E APRIL 17,1995 4-17.1995 X NA
B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in 89.
FIS Profile ® FIRM Community Determined Other (Describe):
B11. Indicate the elevation datum used for the BFE in 89: ® NGVD 1929 NAVD 1988 Other (Describe):
B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? Yes ® No Designation Date
SECTION C - BUILDING ELEVATION INFORMATION (SURVEY REQUIRED)
C1. Building elevations are based on: Construction Drawings' Building Under Construction' ® Finished Construction
A new Elevation Certificate will be required when construction of the building is complete.
C?. Building Diagram Number 1(Select the building diagram most similar to the building for which this certificate is being cr,mrleted - see pages 6 and 7. If no diagram
accurately represents the building, provide a sketch or photograph.)
C3. Elevations — Zones Al-A30, AE, AH, A (with BFE), VE, V1430, V (with BFE), AR, ARIA, AR/AE, AR/A1-A30, AR/AH, AR/AO
Complete Items C3.-ami below according to the building diagram specified in Item C2. State the datum used. If the datum is different from the datum used for the BFE in
Section B, convert the datum to that used for the BFE. Show field measurements and datum conversion calculation. Use the space provided or the Comments area of
Section D or Section G, as appropriate, to document the datum conversion.
Datum NGVD29 Conversion/Comments _
Elevation reference mark used SEMINOLE CO. Does the elevation reference mark used appear on the FIRM? Yes ®No
o a) Top of bottom floor (inducing basement or enclosure) 50.7 fL(m)
o b) Top of next higher floor NA ft.(m) a
o c) Bottom of lowest horizontal structural member (V zones only)
o d) Attached garage (top of slab) 50.4 ft.(m) 00M.,
o e) Lowest elevation of machinery and/or equipment w
servicing the building (Describe in a Comments area) 49.8 ft.(m) E 2
o f) Lowest adjacent (finished) grade (LAG) 49.4 fL(m) z' 0
o g) Highest adjacent (finished) grade (HAG) 50.2 ft.(m)
N
o h) No. of permanent openings (flood vents) within 1 ft. above adjacent grade NA 8
J
o i) Total area of all permanent openings (flood vents) in C3.h NA sq. in. (sq. cm)
SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION
This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information.
I certify that the information in Sections A, B, and C on this certificate represents my best efforts to interpret the data available.
1 understand that any false statement may be punishable by fine or imprisonment under 18 U. S. Code, Section 1001.
CERTIFIER'S NAME MARK I. LUKE LICENSE NUMBER LS 5006
TITLEMANAGING MEMBER COMPANY NAME HENRICH-LUKE & SWAGGERTY, LLC
ADDRESS CITY STATE ZIP CODE
SIGNATU DATE TELEPHONE
L 03-23-05 407 647-7W
FEMA Form 81-31, January 2003 See reverse side for continuation. Replaces all previous editions
IMPORTANT: In these spaces, copy the corresponding information from Section A
BUILDING STREET ADDRESS (IndudV9 Apt, Unit Sure, and/or Bldg. No.) OR P.O. ROUTE AND BOX NO.
For Irsuranoe Company Use:
Polwv Number
212 W. 20TH STREET
CITY STATE ZIP CODE Company NAIC Number
SANFORD FL 32772
SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION (CONTINUED)
Copy both sides of this Elevation Certificate for (1) community official, (2) insurance agenUcompany, and (3) building owner.
COMMENTS
LOWEST MACHINERY SERVICING BUILDING IS AIR CONDITIONING EQUIPMENT
Check here if attachments
SECTION E - BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A (WITHOUT BFE)
For Zone AO and Zone A (without BFE), complete Items Et through E4. If the Elevation Certificate is intended for use as supporting information for a LOMA or LOMR-F,
Section C must be completed.
El. Building Diagram Number _(Select the building diagram most similar to the building for which this certificate is being completed — see pages 6 and 7. If no diagram accurately
represents the building, provide a sketch or photograph.)
E2. The top of the bottom floor (including basement or enclosure) of the building is _ ft.(m) _in.(crm) above or below (check one) the highest adjacent grade. (Use
natural grade, if available).
E3. For Building Diagrams 6-8 with openings (seepage 7), the next higher floor or elevated floor (elevation b) of the building is _ ft.(m) _in.(cm) above the highest adjacent
grade. Complete items C3.h and C3.i on front of form.
E4. The top of the platform of machinery and/or equipment servicing the building is _ ft.(m) _in.(crm) above or below (check one) the highest adjacent grade. (Use
natural grade, if available).
E5. For Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's floodplain management ordinance?
Yes No Unknown. The local official must certify this information in Section G.
SECTION F - PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION
The property owner or owner's authorized representative who completes Sections A, B, C (Items C3.h and C3.i only), and E for Zone A (without a FEMA4ssued or community -
issued BFE) or Zone AO must sign here. The statements in Sections A, B, C, and E are corned to the hest of my knowledge.
PROPERTY OWNER'S OR OWNER'S AUTHORIZED REPRESENTATIVES NAME
ADDRESS CITY STATE ZIP CODE
SIGNATURE DATE TELEPHONE
COMMENTS
Check here if attachments
SECTION G - COMMUNITY INFORMATION (OPTIONAL)
The local official who is authorized by law or ordinance to administer the communitys floodplain management ordnance can complete Sections A, B. C (or E), and G d this Elevation
Certificate. Complete the applicable item(s) and sign below.
G1. The information in Section C was taken from other documentation that has been signed and embossed by a licensed surveyor, engineer, or architect who is authorized by state
or local law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.)
G2. A community official completed Section E for a building located in Zone A (without a FEMA4ssued or communityassued BFE) or Zone AO.
G3. The following information (Items G4-G9) is provided for community floodplain management purposes.
G4. PERMIT NUMBER G5. DATE PERMIT ISSUED G6. DATE CERTIFICATE OF COMPUANCE/OCCUPANCY ISSUED
G7. This permit has been issued for. New Construction Substantial Improvement
GB. Elevation of as -built lowest floor (including basement) of the building is: — _ft(m) Datum:
G9. BFE or (in Zone AO) depth of flooding at the building site is: _ _ ft(m) Datum:
LOCAL OFFICIAL'S NAME TITLE
COMMUNITY NAME TELEPHONE
SIGNATURE DATE
COMMENTS
Check here if attachments
FEMA Form 81-31, January 2003 Replaces all previous editions
rfll INTY ('11-` F
C:-T-^TI:71,IWI,I T'
I yv
UL_.0 7-1-64-
TTYT (r, rry INTY 1,1111YIPPR'n
I INTT A T) T) P P- q cz 24 1— \N 9.()
F%. yj ll::-
LANf,',4L1.) VV? '501; DIV-
PI AT vinnv. 2-PI AT r, nf.) I" PA('11 -
JA1'AP__S AAPAVEI/\- 13"&C- 102,
JBCL.61AN wAY_SAA)FosXo (_L 12-773 1,
141-117r. 34M(S AAPAdA 1- - Ay)
T)Rr5;-,: I b J.- -0 Pj _32-7_73 j\ r\I po v ANT)
1151F r * ATi=,f,,ni;!y t oo, v T)-+.' TYPE
WORK
T)FSrRTPTTnNt M.t, ho i BFNFF
T T P I IN T T RATP PI R it X TYF'I'= T(ITAI . T)l 11: TYFT
DIST F_JE'Dtjj. F7. M_-Rr. I IN'I'T ROADS)
dW1
unit 14 705.00 70'b .00 ARTERIALS
CO--W'EDI= 0 ROADS
142.
00 142.00 COLLEC
TORS NORTH d w I Lk II i IL $ L
1BRARY CO -WIDE 0 CjW3. Unit $ 54.00 1 $ 54.00 SCHOOLS
CO --WIDE_ 0 dwl Lkl')i-t $1.384.00 1 $ 1..384.00 AMOUNT
DUE $ 2.285-00 STATEDIL..
111T IrO:::
C;E]:VE:.D r3y: JAMRA G)-A" SIGNATURE.: 1:11
FARIZ: PR,r.l.4T NAMI_ ) V o
NOTE TO
I-,I'zf-FTVTIlr, 'RTRIIATr1IRY/AI='PI TrANTT FATI IIRI- TF1 Nf-IT-rry nuI,-ji*:*I-.e (,..NI-4y) I:::N1,
3l..JRE TIVIEL.Y PAYMENT MAY RESUI..T TN yCjjli;:• I i,Awri 'fTY F(IR THF FFF, DISTR*I*
Pt.ITmmt 1 -rfll INTY _rvy-y 4 A"
I'll INTY Nf1T1=)K* -
1-5,
A RT6TFVIFNT CIF FFF R WH T ("H ARI,: AY)
VI F,FM THAT TI-H R rdz, ni
ii':' ANY) 1=14Y41:41''I'nRTf') I^Fif,P I'll= 6 r4i I*FI n'I'Mf. 1--1:71r.-MIT I cm
AT)VT5,r'1) THAT ANY ;:,MHTS nr-- THS' . Appl m r1IjNPR_ Tn f*
Ar,r,l*-Al TH'I= r^I rill e.%-r-rnNq f-jI:- TWIL- Tr4RAiz-y c:ZYQTI7IA Aljn/nR EDLJlF'AT'
I:F)NAI. (qrl-inni ) rrtr,Ar.T F-Fpp, rll IqT PP.- p, y p* Fz r,r q Fm 14Y VTI TNr, A wR, .
ri"rpN Ri7n1117qT ILITTI.4'r11 45 ('^1 T)Ayq f11, 7141- IZ. IZ VI, I'l f1 MFII I
ATF-P THAN F'Vr,,T T F 1'r.ATW ni:7 nr,r,.ilr,AF4r,y riv,, Fjf-r.
IIPANrY_ THP pPnIIPRT Pfllq' j;.I*:'5j'rI'-I,I IIII(Q-T 1111=17T TI-IP INTY I
ANT) I)F'VF:'l nP'MFI,JT rr)T)r:' . nP THr' pill Pq r;F1VFPNTF4R, PPI"Al MAY v(
p r,*rrvr--n ltP np ll'*'qTl*-n i=iz,nl,l T1.417 PI AN I PTF",,
qT c,^Fjr.,rm7). Fl r)F,,TYN^ I7,AYI11.
FNT qH(Illl T) T41- ilAnl:Tf*I t f—rTy nP q^NP(IRT) Fill'il
TYH%lf'4 T)F:"PARTIyIFNT cZ^I,
II:.,f,W.Y,1 1:71 pAylvilz"HT
c,WnIll'T) PP ray CAI-, ('11::-MrO nh,n C%ucnl 11 n -7- 1 17* F,'TATF-
MF--I,IT KII ll,IT:4pre ANy) r'I'T Y V41 I I'l T)'I* IJ f": T NI IMPr'R AT TI--IP* TrIP I 171=
T' VIP TI-4P 5,TATp-
1,1F:wT rc, mm -r.n rim y *m rnm.1liwr'T,rnKj WTT4.1 Tc%,c',1IA-KIf,,P.- nr-- 4,**w dew** CC)
oco
THIS INSTRUMENT PREPARED BY:
Patricia L. Coulton
D.R. Horton Inc.
6250 Hazeltine National Drive, Ste.: 102
Orlando, Florida 32822
RECORD AND RETURN TO:
James Blagg
102 Belgian Wayy
Sanford, FL 32773
NOTICE OF COMMENCEMENT
Prepare in duplicate)
ehlIAMLE COUNTY --- "r Wfcu1T COURT
BR 05303 PS 0732CLERKS # 2004073985RECOWDe5/13jL*q% #9145418 AN
RECMRDe BY L
6. M
MN(inl y
The undersigned hereby gives notice that improvement will be made to certain real property, and in accordancewithChapter713, Florida Statutes, the following information is provided in the Notice of Commencement.
DescripPtion of property
Lot 142 Sanford Heights Addition, Plat Book2, Page(s) 62 & 63, Public Records of Seminole County, Florida
General description of improvements: Single Family Dwelling
Owner(s): James Blagg
Address: 102 Belgian Wey Sanford, FL 32773
Owner's interest to site of the improvements: Fee Simple
Fee Simple Title Holder (if other than Owner):
Name: Phone #:
Address: Fax #:
Contractor:.Owner Builder Phone #: 407-302-9687 Fax #: Address: 102 Belgian Way Sanford, FL 32773
Surety (if any):
Address: Phone #:
Amount of bond: $0.00 Fax #:
Lender: Phone #:
Address: Fax #:
Persons within the State of Florida designated by Owner upon whom notices or other documents may be served asprovidedbySection713.13(I)(a)7, Florda Statutes:
Name:
Address:
In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided inSection713.13(1)(b), Florida Statutes:
Name:
Address:
Expiration date of Notice of Commencement: (the expiration date is one (1) year from the date of recording unless adifferentdateisspecified):
By:_James Bla
STATE OF FLORIDA
COUNTY OF ORANGE
The foregoing instrument was acknowledged before me this /D day of / r 2004byJamesBlagg, owner of above mentioned property. He is persona y known to me.
Notary Public, State and County Aforesaid
OFFICIAL :1'•7rARYSEAL
P'A'IRI:. :! .TON
NOTARY110,iLK::>rAT.'•1 a.OKIDA
0
CON:.!S?IOiV KQ r,0134330
i MYCOMM!SS!ONEXP. JULY26XMiignatureNotarySeal
CITY OF SANFORD PERMIT APPLICATION
Permit # : C)IA r
Date: .1'—/ 3— 04'
Job Address: Z/ Z W . Za Dui ET
Description of Work: N (W (,1-1 h) S t X\) (--"(J Q N) S/ /I/ 6 IL C-A N/LI iMI%J P
Historic District: )V 11 Zoning:: RAA Value of Work: Su O Fi 0 0
Permit Type: Building Electrical Mechanical Plumbing Fire Sprinkler/Alarm Pool
Electrical: New Service — # of AMPS 2,Q f1 Addition/Alteration Change of Service Temporary Pole _,/
Mechanical: Residential V Non -Residential Replacement New 1/ (Duct Layout & Energy Calc. Required)
Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lines
Plumbing/New Residential: # of Water Closets 2- Plumbing Repair — Residential or Commercial
Occupancy Type: Residential Commercial Industrial Total Square Footagfte: k.2=9 (41
Gonstructi"ontiTypei-L.1I-.# of Stories: j- # of Dwelling Units: Flood Zone: Y (FEMA form required for other than X)
Parcel q: 3 r, — 14 — -5 Q — U —
77 —
i 7- (Attach Proof of Ownership & Legal Description)
Owners Name & Address: a A M C. -, A 4 PA & MIP tl [4/G_ _
Contractor Name & Address:
State License Number.
Phoned, r--• —
Bondlnp 1
Address
Mortgage
Address:
Architect
Address:
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to theissuanceofapermitandthatallworkwillbeperformedtomeetstandardsofalllawsregulatingconstructioninthisjurisdiction. I understand that a separate
permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and
AIR CONDITIONERS, etc.
Z/-?-2S-314/
OWNER'S AFFIDAVIT: 1 certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulatingconstructionandzoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING
TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of
this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies.
Acceptance of ermit is verify io that l will notify the owner of the property of the requirements of Florida Lien Law, FS 713.
NA 1 a ZU
nature of Owner/A 11, Date Signature of Contractor/Agent
JAME, 92-A (r
Prinl`Owner/Agent's Name
n Print Contractor/Agent's Name
taryState of Flo •da Date
DEBBIE BLANTOW
MY COMMISSION # DD 188491
cYataES: February 25.2007
Date
Signature of Notary -State of Florida Date —
r+wnevxgent rs to Me or
t( soo OTPfliducedF , Contractor/
Agent is _Personally Known to Me or t
M 4i3 ' q6 S- O _ Produced I D APPLICATION
APPROVED BY: Bldg: ?16 k , L1 Zoning: F T Utilities: Q FD: Initial &
Date) (Initial & Date) (Initial Date) (Initial & Date) Special
Conditions: -r ,
f AOIL, lA ee}`.' 5-CSa,ke L .. loT C1eoe loe94 d s . 4 N{...tr .n siC 1 14 5'1 4.
0. Su
CITY OF SANFORD BUILDING DIVISION
OWNER/BUILDER AFFIDAVIT
CONSTRUCTION CONTRACTING
Owners of property when acting as their own contractor and providing direct, onsite supervision
themselves of all work not performed by licensed contractors, when building or improving farm
outbuildings or one -family or two-family residences on such property for the occupancy or use of such
owners and not offered for sale or lease, or building or improving commercial buildings, at a cost not to
exceed $25,000, on such property for the occupancy or use of such owners and not offered for sale or
lease. In an action brought under this part, proof of sale or lease, or offering for sale or lease, of any such
structure by the owner -builder within 1 year after completion of same creates a presumption that the
construction was undertaken for purposes of sale or lease. This subsection does not exempt any person
who is employed by or has a contract with such owner and who acts in the capacity of a contractor. The
owner may not delegate the owner's responsibility to directly supervise all work to any other person
unless that person is registered or certified under this part and the work being performed is within the
scope of that person's license. For the purposes of this subsection, the term "owners of property"
includes the owner of a mobile home situated on a leased lot. To qualify for exemption under this
subsection, an owner must personally appear and sign the building permit application.
State law requires construction to be done by licensed contractors. You have applied for a permit under
an exemption to that law. The exemption allows you, as the owner of your property, to act as your own
contractor with certain restrictions even though you do not have a license. You must provide direct,
onsite supervision of the construction yourself. You may build or improve a one -family or two-family
residence or a farm outbuilding. You may also build or improve a commercial building, provided your
costs do not exceed $25,000. The building or residence must be for your own use or occupancy. It may
not be built or substantially improved for sale or lease. If you sell or lease a building you have built or
substantially improved yourself within 1 year after the construction is complete, the law will presume that
you built or substantially improved it for sale or lease, which is a violation of this exemption. You may
not hire an unlicensed person to act as your contractor or to supervise people working on your building. It
is your responsibility to make sure that people employed by you have licenses required by state law and
by county or municipal licensing ordinances. You may not delegate the responsibility for supervising
work to a licensed contractor who is not licensed to perform the work being done. Any person working
on your building who is not licensed must work under your direct supervision and must be employed by
you, which means that you must deduct F.I.C.A. and withholding tax and provide workers' compensation
for that employee, all as prescribed by law. Your construction must comply with all applicable laws,
ordinances, building codes, and zoning regulations.
I, 3 AM r_ S A , B LA & Cr , do hereby state that I am qualified and capable of performing the
requested construction involved with the permit application filed.
I will assume full responsibility as an Owner/Builder Contractor, and will personally supervise all work
allowed by law on the permitted structure.
10y t3 2ot A-
wner udder gnature Date
4 Mr s A . 8L-Acr+,
Print Owner/Builder Name DEBBIE BI ANTON
MY COMMISSION # DD 1884.91
EXPIRES: February 25, 2007NOrARYFL
Signature of Notary —State of Florida Date
Owner is Personally Known to Me or has
Produced ID F h L- A, y 16- L/L// -` J- qC.9- O e" .
r L-12-V0y
CITY OF SANFORD BUILDING DIVISION
OWNEWBUILDER AFFIDAVIT
ELECTRICAL & FIRE ALARM SYSTEMS
An owner of property making application for permit, supervising, and doing the work in connection with
the construction, maintenance, repair, and alteration of and addition to a single-family or duplex residence
for his or her own use and occupancy and not intended for sale or an owner of property when acting as his
or her own electrical contractor and providing all material supervision himself or herself, when building
or improving a farm outbuilding or a single-family or duplex residence on such property for the
occupancy or use of such owner and not offered for sale or lease, or building or improving a commercial
building with aggregate construction costs of under $25,000 on such property for the occupancy or use of
such owner and not offered for sale or lease. In an action brought under this subsection, proof of the sale
or lease, or offering for sale or lease, of more than one such structure by the owner -builder within I year
after completion of same is prima facie evidence that the construction was undertaken for purposes of sale
or lease. This subsection does not exempt any person who is employed by such owner and who acts in
the capacity of a contractor. For the purpose of this subsection, the term "owner of property" includes the
owner of a mobile home situated on a leased lot. To qualify for exemption under this subsection, an
owner shall personally appear and sign the building permit application.
State law requires electrical contracting to be done by licensed electrical contractors. You have applied
for a permit under an exemption to that law. The exemption allows you, as the owner of your property, to
act as your own electrical contractor even though you do not have a license. You may install electrical
wiring for a farm outbuilding or a single-family or duplex residence. You may install electrical wiring in
a commercial building the aggregate construction costs of which are under $25,000. The home or
building must be for your own use and occupancy. It may not be built for sale or lease. If you sell or
lease more than one building you have wired yourself within I year after the construction is complete, the
law will presume that you built it for sale or lease, which is a violation of this exemption. You may not
hire an unlicensed person as your electrical contractor. Your construction shall be done according to
building codes and zoning regulations. It is your responsibility to make sure that people employed by you
have licenses required by state law and by county or municipal licensing ordinances.
1, J A M GS la . W-A(rl/' do hereby state that I am qualified and capable of performing the
requested construction involved with the permit application filed.
I will assume full responsibility as an Owner/Builder Contractor, and will personally supervise all work
allowed by lacy on the permitted structure.
AJPME/ 13 v
cr/Builder S ' Date JAlVifS
A-&ACrl., Print
Owner/Builder Name DMMBSI
MEXPRES: oe
DOON Sig
ature of Notary —Slate of Florida Date TARY Feb"'e'Y2s 99j orary
Olxoum 2 07 hoc.
Co. Owncr
is Personally Known to Me or has Produced
ID pi) I_ (ydy- yy/-'/3- IfVp -
12-/Lgl0`/
ST
J CO2 TRC?!_
V', a! !/roam
Sentricon* Colony Elimination System
Pretreatment Plan Agreement
Dace of Install :
Contract Number
dime
Address. i WAN
C(t/State/Zip D.
Phone S, Email 40 7- T67 —9J1
Quarterly Payment Amount 1.
First payment due on the Install Anniversary Date)
Any payment deemed 30 days past due tivlll result
In the cancellation of this Warranty and Justify
removal of the Sentricon System.
Name JAN GS AA, BLACye,
Address
City/State/Zip
Phone & Emall
INSTALLATION ADDRESS: 21 Z W.
SPECIAL OR A.DDITIONAL.COMMENTS
NOTIFICATION STICKER LOCATED: Ru t-r-
DAMAGE REPAIR WARRANTY From the date of Installation of the Sentricon* Colony Elimination System, Apex tivlllarrantthestructure(s) against subterranean termite damage. If subterranean termite damage occurs to the describedpropertyduringthewarrantyperiod, Apex will, upon notification and Inspection, arrange for the necessary repairs and paythecostoflaborAndmaterialsnottoexceed $1,000,000. Apex may chemically treat the affected area of the property at noadditlonalcosttotheCustomer.
THE UNDERSIGNED CONSENTS TO AND AUTHORIZES THE WORK CONTEMPLATED HEREIN, AND FURTHERAGREESTHATTHETERMSANDCONDITIONSSTATEDONEITHERSIDEOFTHEAGRE00VEFNTHERELATIONSHIPOFTHEPARTIES. EMENT SHALL
Apex Representative Signature Date Customer or Agent Signature Date. Apex Pest Control Inc.) (Apex) will, In substantial compliance with fill federal, state, and local laws, rules, and re ulatlallapplicablerecommendationscontainedinliteratureprovidedbyDowElanco: g ons, andI
install Sentrlcon* stations (the Stations) In the soar around the outside perimeter of the'structure(s), 2.
monitor those Stations for twelve months from ttie date -hereof; 31 during those years, add Recruit* termite balt and rerhove it4. during those years, Inform theZustomer of: from the Stations as appropriate; anda.
any new or Increased termite Activity. noted at the Stationsb,
any addition or. removal of Recruit* of Recruit* termite bait; andc
any observed 'effect of the Sentricon Colony Elimination System (Sentricon) on termite activityTheCompanywillextendthisServiceCommitmentfollowingtheoriginaltwelvemonthobligation. Pretreatment Plan may
maintained for the LIFETIME of the Identified property subject to the termagreement
forfter
g on. The Sentricon
the fifth year, and each year thereafter, Apex period) Payable o
to revise
t e end f the previous monitoringsandconditions of this
per %,car,
q rly payment amount, notgto exceedl0%,
The Customer warrants full cooperation with Apex during the term of this Agreement, and abaitedfreefromanyfactorscontributingtolnfestatlonsuchaswood, trash, lumber, direct wunderpiertypestructure, or as noted In "Special or Additional Comments"
agrees to maintain the arca(s)
eliminate faulty plumbing; leaks; dampness from drains; condensation or leaks from the
wood -soil contact, standing water. the area(s) balled.
b
no time will damage caused to an The Customer also agrees to notify Apex of andInsectInfestation,
bane
be the
o time will
of Apex
u
areas where any (
s
the conditions de
roof or otherwise Into, onto, or undery
re Piny f e
the
conditions describedeven by an active wood destroyingOfApextoalerttheCustomertoanyoftheaboveconditionsdoesnotaltertheCustomerscribedinthisParagraphexist, FailureDISCLAIMER; COMPANY DISCLAIMS ALL OTHER yyA AN
s responsibility under this paragraph. INCLUDING STATUTORY W TIES, MERCHANTAgII,ITY, FITNESSA FpR TIES, AND PECIFICALLY DISCLAIMS EXPRESS OR IMPLIED, FURTHER, COMPANY HAS MADE NO PURPOSE, OR W ANY IMPLIED `''ARFtAINTES pgSERvICEPROVIDEDMATIONOFFACTORPROMISERELATINGOFWORI{MANLIKE SERVICE.' Customer expressly waives And releasesUeHEREUNDERDER any ialmHAS
any laTED OR L'
iE-PRODUCT ORnegligence, torts, personal Injury, AMOUNTED TO AN EXPRESS W1ry, death, viola of any statute, rule, or regulation, loss of use, dtml ut
ARRANTYcompensatory, Ihcidental, consequenttfil, exem la
t+ or regulation,
rntlon or other legal
event shall Apex be liable for any Amount greater that amoun
g Proceeding against Apex forexemplary, punitive,
aid b
liquidated, treble, or special damages If any kind, andInnc) tpaidbytheCustomertoApexfortheservicetobeperformed. o
SENSITIVITY/PHYSICAL FACTORS' Customer understands and agrees that (1)it Is the responsibility of all family members, vlsltors,
guests, and/or other temporary or permanent occupants to consult a physician If necessary regarding any affects the Property treatmentmayhaveand (2)lt Is their responsibility to notify Apex in writing not less than two (2) days prior to treatment regarding any•ailergy orsensitivityconcerningodors, dust, pollen, respiratory illness, or other condition that may be activated or exacerbated by the products and or
techniques utilized by Apex.
GENERAL TERMS AND CONDITIONS
By specific reference hereto, the Customer understands that the general terms and conditions are hereby made part of this contract and
apply without exception.
I, DOWELANCO OWNERSHIP OF SENTRICON" SYSTEM COMPONENTS: The Customer understands that: All components
of the Sentrlcon *System (Components) are and will remain to property of DowElanco. The Customer has no rights to any of the
Components, and the Purchaser may not alter, remove, or modify the components In any way, other than the right to their use as
Installed by Apex on the Customer's premises under this agreement.
On expiration or termination of this Agreement, Apex and DowElanco or Its representative are authorized by the Customer co
retrieve from the Customer's premises the Stations and other Components contained therein for appropriate disposition.
1. If Apex, for whatever reason, ceases to represent or to be authorized to represent, the Sentrlcon" System
a. Apex will, (1)so notify the Customer; (2)offer Customer the alternatives of either using a different form of termite protection
or discontinuing the relationship(noter Conventional "liquid barrier" method of termite control may not offer an effective
means of controlling certain termite Infestations of certain structures. In such event Apex may not be able to offer a different
form of termite protection, and therefore may have to discontinue the relationship.); (3)lf the Customer and Apex (Parties)
agree on use of a different form of termite protection, give the Customer credit for service paid for but not yet recclved; (4)If
the Customer elects to discontinue the relationship, or If Apex cannot offer an effective different -form of termite profectlon,
refund to the Customer an amount equal to the fee paid for services not yet received, andt(S)retrleve, or advise DoWElanco-or
Its representatives where to retrieve, the Components from the Customer's premises, and
b. the Customer will; (1)grant Apex and DowElanco or Its representative reasonable access to the premises for the retrieval of
the Components; and; (2)either agree with Apex on the use of a different form of termite control or elect to discontinue this
relationship.
ADDITIONS AND/OR ALTERATIONS This Agreement covers the Structure(s) Identified herein as of the date of the Initial Installation.
Prior to; (1)the Structure(s) being structurally modified, altered, or otherwise changed on (2) to any termltieide being applied on or close to
the location of any Station, or; (3) soil Is removed or added around the foundation, or; (4) any tampering -of baiting equipment or supplies
occurs, the Customer will Immediately notify Apex In writing. Failure to notify Apex In writing of the events listed above may void this
Agreement. Additional services because of any alteration, addition, or other such event, may be provided by Apex at the Customers
expense, and may require and adjustment In the annual fee.
DAMAGE RELATED TO SERVICE Apex will exercise due care while performing any work hereunder In avoidance of damaging any pan
of the Customer's property, plants, or animals. Under no circumstances or conditions shall Apex be responsible for damage caused at the.
time the work Is performed except those damages resulting from gross negligence on the part of Apex.
PAYMENT/DEFAULT. All payments due pursuant to this Agreement shall be made at the Apex Corporate Headquarters located In
Merritt island, Brevard County, Florida. In the event of failure to make payment when due, or any other default by Customer (1) Apex may
without notice., terminate this Agreement and pursue all other avallable remedies, which shall be cumulative, and (2) Interest shall accrue at
the highest rate allowed by law during the period of any delinquency, and (3) Customer agrees to pay all costs and attorneys fees Incurred by
Apex, whether or not suit Is brought.
VENUE/SEVERABILITY. Venue for any and all legal proceedings shall be In Brevard County, Florida. If any part of this Agreement is
held to be Invalid or unenforceable for any reason, the remaining terms and conditions of this Agreement shall remain In full force and
effect.
CHANGE IN LAW. In the event of a change In applicable law as It pertalr>s to the services promised herein, Apex reserved the right, to
revise the annual extension charge or terminate this Agreement.
DISCLAIMER/CONDUCIVE CONDITIONS Apex's liability under this Agreement will be terminated If Apex is prevented from fulfilling
Its responsibilities under the terms of this Agreement by any reason of delays in transportation, shortages of fuelJor matert ils, strikes,
embargoes, fires, floods, hurricanes, storms, quarantine restrictions, or any other act of God or circumstances beyond the control of Apex.
Apex disclaims any liability for special, Incidental, or consequential damages. This Agreement does not cover and Apex will not btresponsiblefor; (1)termite damage resulting from water leakage; (2)termite damage resulting from masonry failure or grade alterntlons:
Mtermlte damage resulting from direct wood to soli contact; (4)furniture and contents; (5)areas of existing damage unless areas have beerrepairedbyCustomer's evidence of receipts.
ARBITRATION. Not withstanding any provision contained herein regarding lltlgatlon, In the event of any dispute arising hereunderCustomeragreestosubmitthedisputetotheleastexpensiveprocedureofarbitrationInaccordancewiththerulesandproceduresfocommercialarbitrationoftheAmericanArbitrationAssociationoranysuccessororganization, and in accordance with and subject to all th
provisions of the Uniform Arbitration Act as In force In the State of Florida, or the Federal Arbitration Act, 9 U.S.C. section 1, et seg. Thproceedingshallbegovernedbyonearbitrator, and the location of arbitration will be Brevard County, Florida at the offices of Apex or i- des gnee. The arbitrator will have the complete power to determine all Issues of fact and law, and any determination of the arbitrators Nvibefinalandconclusive, and binding on both parties. Customer agrees that any such arbitration shall be conducted on an Individual bnsiandnotnclasswidebasis. Apex shall recover all fees, costs, and attorneys fees associated with the arbitration proceeding. ENTIRE AGREEEMENT. The service Agreement signed at the time of purchase constitutes the entire Agreement between the panics arnootherrepresentationsofstatementswillbebindingontheparties. REFUNDS. Apex at any time on or after 36 (thirty-six) months from the Initial date of installation, terminate this Agreement andrelievedofanyliabilityhereunderIfApexdetermines, In Its sole discretion, that It Is unable to prevent or stop further damage to Properfromsubterraneantermiteactivity. Partial refunds may be made under the discretion of Apex Pest Control Inc. NOTICE OF CLAIMS, ACCESS TO PROPERTY. Any claims under the terms of this Agreement must be made Immediately in writingTheApexCorporateOffice. Apex Is only obligated to perform under this Agreement If the Customer allows Apex access to the Identif. Property for any purpose contemplated by this Agreement, Including but not limited to re -Inspection, whether the Inspection was requcs: by the Customer or considered necessary by Apex.
LIMITED ASSIGNABILITY. This Agreement Is assignable by Customer for a period of 1 (one) year from Its cffetitive date. After tInitial12 (twelve) month period, Customer may transfer or assign this Agreement with a transfer fee payable to Apex %Ylthinthirty) days of the transfer of the treated Property.
Trademark of DoWElane0
Brevard Area Orlando Area508SPlumosaSt. 7006 Stapolnt Ct. #C Tampa/Sarasota Area
Merritt Island, FL 32952 Wlnterpnrk, FL 32792 5314 Faulkenburg Rd N
407-459.2847 407.858.0540 Tampa, FL 33510
800.929.2847 888-764.2847 813.221.2847
877-459.2847
l
BOUNDARY SURVEY FOR: o19/VES /9, 4gGAGC
DESCRIPTION: LOT 142. SANFORD HEIGHTS ADDITION, ACCORDING TO THE PLAT THEREOF AS
RECORDED IN PLAT BOOK 2, PAGES 62 AND 63 OF THE PUBLIC RECORDS OF
SEMINOLE COUNTY, FLORIDA.
116
REC.1/2"I.R.
No/) N 89'53' 25"
14' Alley, r J
Plat —Open, lrt
F4nce Coro.r,
2.2'S. 0.B'w.
motel Roc11
a
141
Edge or/
lS
MEa
1
7 JROtril)lbO4
i
OEAD
REMOVE
117
53•P.
00
E 53. 12M. To aP, Pol-G 142
AFL
ET /
8'.R.(L.S13764) LLS
REC.1/2"I.R.(L.S. 331130.50'E. Qgly '
1
Slab
f
F
U.
O
W
Z
a
3
4I
ci W
O= I
a
xW
0:
O METER
BASE i+ 200
AMP 4TOV A/c UQIT =ch PALM
KEEP I-
Z
141
PIAIES
e
10 I
W
J
rw 3 F•
c• Cot 7;w IL ,00 Z,ao i,o1 0 W 0.
1 w. p 0
0a-OAK 3rDIA, d I o CT
1(G 5P N
89'54' 50" E .5 a'30- M. SET 5/8'I.R.(L.S.3764)W
NO/)
S3'P: , LSO REC.1/2'I.R.(L.S. N
1 382) 0.48'E. N PPC0PQS5D
CVR$ CVT 20TH.
STREET PUBLIC
R/W-OPEN,PAVED) AODRES5:
Z12 W• ZQTH.STRBE'f z
OV
W
W LA
m a
V1 03aW
W
aWC4
VN
za -
m
N N
SCALE.:
1"=30' DATE
OF: BOUNDARY:
2-17-04 FOUND:
FINAL:
x
N
C
1.
THIS PROPERTY LIES IN FLOOD ZONE "K', PER SWAGGERTY
LAND F.E.M.A. FLOOD INSURANCE RATE MAP, COMMUNITY -PANEL INC.
NUMBER 120294 0045 E. DATED APRIL 17, 1995. SURVEYING, LICENSED
BUSINESS No.4Y06 2. TITLE DATA HAS NOT BEEN FURNISHED TO THE SURVEYOR. 1450
KASTNER #LACE, SUITE 100 3. UNDERGROUND IMPROVEMENTS HAVE NOT BEEN LOCATED. Box
23 P.O. FLORIDAJ2772-
2384 SANFORD, 4. NOT VALID UNLESS SEALED WITH AN EMBOSSED SEAL. 407)
322-4630 FAX (407)322-8011 5. THIS PROPERTY LIES IN SECTION 36. TOWNSHIP 19 SOUTH, RANGE
30 EAST, SEMINOLE COUNTY, FLORIDA. ABBRE
VIA TIONS: CERTIFIED CORRECT TO: REC.
DENOTES RECOVERED C.B. DENOTES CONCRETE BLOCK C.
M. CONCRETE MONUMENT W.F. WOOD FRAME I.
P. IRON PIPE RES. RESIDENCE I.
R. IRON ROD CONC. CONCRETE P,
CENTERLINE A.C. AIR CONDITIONER R/
W RIGHT-OF-WAY UTIL. UTILITY R.)
RADIAL DRAIN. DRAINAGE I HEREBY CERTIFY THAT THE SURVEY SHOWN N.R.) NON -RADIAL ESMT. EASEMENT HEREON WAS MADE IN ACCORDANCE TO THE R.P. RADIUS POINT L.S. LICENSED SURVEYOR MINIMUM TECHNICAL STANDARDS' FOR LAND P.
C. POINT OF CURVATURE L.B. LICENSED BUSINESS SURVEYING IN THE STATE F FLORIDA CH. P.T. POINT OF TANGENCY P. PLAT 472.027 A CH. 61 17 P.
R.C. POINT OF REVERSE M. MEASURED E
D. DESCRIPTION GATE: Z-04.04 P.C.C. PONTCURVAOFRCOMPOUND C. CALCULATED MARK.
I. LUKE PSM/5006 CURVATUREn'
1
BOUNDARY SURVEY FOR: I:/AlW46S A. 464AG6
DESCRIPTION: LOT 142. SANFORD HEIGHTS ADDITION. ACCORDING TO THE PLAT THEREOF AS
RECORDED IN PLAT BOOK 2. PAGES 62 AND 63 OF THE PUBLIC RECORDS OF
SEMINOLE COUNTY. FLORIDA.
115 116 117
REC.t 2'I.R. 33P.
No/ N 89'53' 2S' E 53. 12 M.
LOT
F3302) 3/6'1.R.(L.S.3764)
14' Alley. Per REC.1/2'I.R.(L.S.
Plat -Open. DJrt g =; " 0.30•E.
ne• Corner _
Meth RMI
Over" s 0
143 ;
O_
b
LLoEZ
one•
0.97.
s
g,C 1 J
F
NEC. 2'1.R. 1N 89'34' SO" ENOW
a
N
g
h
3t 141
4
4
g
I
I !r
I N
i0
211' -
53. 3G' AL SET 3/8'I.R. (L.S.4764)
331P. ALSO REC.1/2'1.R.(L.S. a3382) 0.46'E. a
20TH. STREET
PUBLIC R/w-OPEN.PAVED)
O
W
Z
1 C
i
1
VI
0:
F'oov
Z+
Ia
1.. O
O0
O WNIII
CDIA
w
W
1/1
tJ N
Ir:
WO
0) N
N
SCALE:1"=30'
DATE OF:
BOUNDARY: 2-17-04
FOUND:
FINAL:
L THIS PROPERTY LIES IN FLOOD ZONE 'X'. PER
SWAGGERTY LAND F.E.M.A. FLOOD INSURANCE RATE YAP. COMMUNITY -PANEL
SURVEYING. INC. NUMBER 120294 0048 E. DATED APRIL 17. 199S.
LICENSED &VfM S$ 100.4904 2. TITLE DATA HAS NOT BEEN FURNISHED TO THE SURVEYOR.
ME0 NASTNER PLACE, Kai 100 J. UNDERGROUND IwROVEMENTS HAVE NOT BUN LOCATED.
P.O. sox 230/ 4. NOT VALID UNLESS SEALED WITH AN EMBOSSED SEAL. 07)322--i6MFAA1A Y (40?)322-"Il 8. THIS PROPERTY LIES IN SECTION 36. TOWNSHIP 19 SOUTH.
RANOE 30 EAST. SEMINOLE COUNTY. FLORIDA.
ABBREVIATIONS: CERTIFIED CORRECT TO.
REC. DENOTES RECOVERED C.B. DENOTES CONCRETE BLOCK
C.Y. CONCRETE MONUMENT W.F. WOOD /RAME
I.P. IRON PIPE RES. RESIDENCE
I.R. IRON ROD CONC. CONCRETE r
CENTERLINE A.C. AIR CONDITIONER
w RIGHT-OF-WAY UTIL. UTILITY
R.) RADIAL DRAIN. DRAINAGE I HEREBY CERTIFY THAT THE SURVEY SHOWN
N.R.) NON -RADIAL MT. EASEMENT HEREON WAS MADE N ACCORDANCE TO THE
P. RADIUS POINT L.S. LICENSED SURVEYOR MINRIUM TECHNICAL STANDARDS' FOR LAND
P.C. PONT 0/ CURVATURE L.B. LICENSED BUSINESS SUIt 4 N THE STATE FLORIDA CH.
P.T. POINT 0/ TANGENCY P. PLAT. A CH. 81 7P.R.C. POINT OF REVERSE M. MEASUREDCURVATURED. DESCRIPTION
4,2021.
DATE:
P.C.C.POINT OF COMPOUND C. CALCULATED
LUK[CURVATURE PSM/b006MEMNON
4 .}
First American Title Insurance Company
870 Sun Drive, Suite 1072
Lake Mary, Florida 32746
Ph. (407) 321-5449 / Fax. (407) 322-4096
February 17, 2004
James A. Blagg and Paula K. Blagg
Lot 142
Sanford, FL 32771
RE: File Name: / Blagg
Property Address: Lot 142,
Sanford, Florida 32771
File No.: 2022-432441-0716
Please find enclosed the final policy of title insurance for the above captioned property. Please keep this
document with your permanent records for this property. The original recorded documents will be
returned to you after recording.
Please remember, if this property qualifies for and you intend to file for homestead exemption for tax
purposes, you must do so prior to February 28, 2004. You must apply for this exemption in person at the
County Property Appraisers Office.
We thank you for the opportunity to be of service to you, In the future should you have any title
Insurance needs, we hope you will allow First American Title Insurance Company to be of service to you
again. If you have any questions or concerns or need anything further, please do not hesitate to contact
this office.
Sincerely,
Closing Team
First American Title Insurance Company
FATIC 524 Policy No.: FA-35-2022-432441
Policy of Tide Insurance
ft a aRi
4 ?+
ISSUED BY
First American Title Insurance Company
SUBJECT TO THE EXCLUSIONS FROM COVERAGE, THE EXCEPTIONS FROM COVERAGE CONTAINED IN
SCHEDULE B AND THE CONDITIONS AND STIPULATIONS, FIRST AMERICAN TITLE INSURANCE COMPANY, a
California corporation, herein called the Company, insures, as of Date of Policy shown In Schedule A, against
loss or damage, not exceeding the Amount of Insurance stated in Schedule A, sustained or incurred by the
Insured by reason of:
1. Title to the estate or interest described in Schedule A being vested other than as stated therein;
2. Any defect in or lien or encumbrance on the title;
3. Unmarketability of the title;
4. Lack of a right of access to and from the land.
The Company will also pay the costs, attorneys' fees and expenses incurred In defense of the title, as Insured,
but only to the extent provided in the Conditions and Stipulations.
First American Tide Insurance Company
By '` o President
V
AMest.• 1q / xd,,t 4 Oflj,Y Secretary
O 2000 The First American Corporation.
All Rights Reserved
ALTA Owner's Policy (10-17-92) (WIth F/odda MadiAgdons)
COMMERCIAL RESIDENTIAL NEW HOME SALE RESALE FORECLOSURE OTHER
SCHEDULE A
Issuing Office File No. 2022-432441-0716 Policy No. FA-35-2022-432441-
0716
Date of Policy: 02/17/2004 Amount of Insurance: $ 28,750.00
or the date of recording of the instrument
executed at closing vesting title in the insured,
whichever is later)
1. Name of Insured:
James A. Blagg and Paula K. Blagg
2. The estate or interest in the land which is covered by this policy is:
Fee Simple
3. Title to the estate or interest in the land is vested in:
James A. Slagg and Paula K. Blagg
4. The land referred to in this policy is described as follows:
See Schedule A attached hereto and made a part hereof
By:
First American Title Insurance Company
J
as Vice President of First American Title Insurance Company
Schedule A (Continued)
Issuing Office File No.: 2022-432441-0716
Lot 142 of "SANFORD HEIGHTS" ADDITION to Sanford, according to the Plat thereof as recorded in Plat
Book 2, Page(s) 63, of the Public Records of Seminole County, Florida.
SCHEDULE B
Issuing Office File No. 2022-432441-0716 Policy No.: FA-35- 2022-432441-0716
EXCEPTIONS FROM COVERAGE
This policy does not insure against loss or damage (and the Company will not pay costs, attorneys' fees
or expenses) which arise by reason of:
1. Any rights, Interests, or claims of parties in possession of the land not shown by the public
records.
2. Any rights, interests, or claims affecting the land which a correct survey would disclose and which
are not shown by the public records.
3. Any lien for services, labor, or materials in connection with improvements, repairs or renovations
provided before, on, or after Date of Policy, not shown by the public records.
4. Any dispute as to the boundaries caused by a change in the location of any water body within or
adjacent to the land prior to Date of Policy, and any adverse claim to all or part of the land that
Is, at Date of Policy, or was previously, under water.
Taxes or special assessments not shown as liens in the public records or in the records of the
local tax collecting authority, at Date of Policy.
6. Any minerals or mineral rights leased, granted or retained by prior owners.
7. Taxes and assessments for the year 2004 not yet due and payable and subsequent years.
NOTE: Exception(s) numbered 1, 3 and 5 above Is/are hereby deleted.
8. Restrictions, dedications, conditions, reservations, easements and other matters shown on the
plat of "SANFORD HEIGHTS", as recorded In Plat Book 2, Page(s) 63, but deleting any covenant,
condition or restriction indicating a preference, limitation or discrimination based on race, color,
religion, sex, handicap, familial status or national origin to the extent such covenants, conditions
or restrictions violate 42 USC 3604(c).
9. Terms and provisions of all agreements and franchises pertaining to the cost, installation,
operation and maintenance of gas, water and/or sewer facilities.
Issuing Office File No.: 2022-432441-0716
Note: All of the recording information contained herein refers to the Public Records of Seminole County,
Florida , unless otherwise indicated. Any reference herein to a Book and Page Is a reference to the
Official Record Books of said county, unless indicated to the contrary.
Notices - Where Sent
All notices required to be given the Company and any statement in writing required to be furnished the
Company shall include the number of this policy and shall be addressed to the Company, Attention:
Claims Department, 1 First American Way, Santa Ana, CA 92707.
service, umain ana AvaII0101111ty
First American Title Insurance Company cares about its customers and their ability to obtain information
and service on a convenient, timely and accurate basis. A qualified staff of service representatives is
dedicated to serving you. A toll -free number Is available for your convenience In obtaining information
about coverage and to provide assistance in resolving complaints at 1-800-929-7186. Office hours are
from 8:30 a.m. through 5:30 p.m. Monday through Friday.
EXCLUSIONS FROM COVERAGE
The following matters are expressly excluded from the coverage of this policy and the Company will not pay loss or damage, costs, attorneys' fees or expenses which arise by reasonof:
I. (a) Any law, ordinance or governmental regulation (Including but not limited to building and zoning taws, ordinances, or regulations) restricting, regulating, prohibiting or relatingto (1) the occupancy, use, or enjoyment of the land; (11) the character, dimensions or location of any Improvement now or hereafter erected on the land; (III) a separation In
ownership or a change In the dimensions or area of the land or any parcel of which the land Is or was a part; or (Iv) environmental protection, or the effect of any violation of
these laws, ordinances or governmental regulations, except to the extent that a notice of the enforcement thereof or a notice of a defect, lien or encumbrance resulting fromaviolationorallegedviolationaffectingthelandhasbeenrecordedInthepublicrecordsatDateofPolicy.
b) Any governmental police power not excluded by (a) above, except to the extent that a notice of the exercise thereof or a notice of a defect, lien or encumbrance resultingfromaviolationorallegedviolationaffectingthelandhasbeenrecordedInthepublicrecordsatDateofPolicy.
2. Rights of eminent domain unless notice of the exercise thereof has been recorded In the public records at Date of Policy, but not excluding from coverage any taking which hasoccurredpriortoDateofPolicywhichwouldbebindingontherightsofapurchaserforvaluewithoutknowledge.
3. Defects, liens, encumbrances, adverse claims, or other matters:
a) created, suffered, assumed or agreed to by the Insured claimant;
b) not known to the Company, not recorded in the public records at Date of Policy, but known to the Insured claimant and not disclosed In writing to the Company by the InsuredclaimantpriortothedatetheInsuredclaimantbecameanInsuredunderthispolicy;
c) resulting In no loss or damage to the Insured claimant;
d) attaching or created subsequent to Date of Policy; or
e) resulting In loss or damage which would not have been sustained If the Insured claimant had paid value for the estate or Interest Insured by this policy.
4. Any claim, which arises out of the transaction vesting In the Insured the estate or Interest Insured by this policy, by reason of the operation of federal bankruptcy, state Insolvency, or similar creditors' rights laws, that R Is based on:
a) the transaction creating the estate or Interest Insured by this policy being deemed a fraudulent conveyance or fraudulent transfer; or
b) the transaction creating the estate or Interest Insured by this policy being deemed a preferential transfer except where the preferential transfer results from the failure:
1) to limey record the Instrument of transfer; or
II) of such recordation to Impart notice to a purchaser for value or a judgment or lien creditor.
1. DEFINITION OF TERMS.
The following terms when used In this policy mean:
a) "Insured": the Insured named In Schedule A, and,
subject to any rights or defenses the Company would
have had against the named Insured, those who succeed
to the Interest of the named Insured by operation of law
as distinguished from purchase Including, but not limited
to, heirs, distributees, devisees, survivors, personal
representatives, next of kin, or corporate or fiduciary
successors.
b) "Insured claimant": an Insured claiming loss or
damage.
c) "knowledge" or "known': actual knowledge, not
constructive knowledge or notice which may be Imputed
to an Insured by reason of the public records as defined In
this policy or any other records which Impart constructive
notice of matters affecting the land.
d) "land': the land described or referred to In
Schedule (A), and Improvements affixed thereto which try
law constitute real property. The term "land" does not
Include any property beyond the lines of the area
described or referred to In Schedule A, nor any right, title,
Interest, estate or easement In abutting streets, roads,
avenues, alleys, lanes, ways or waterways, but nothing
herein shall modify or limit the extent to which a right of
access to and from the land is Insured by this policy.
e) "mortgage: mortgage, deed of trust, trust deed,
or other security Instrument.
f) "public records": records established under state
statutes at Date of Policy for the purpose of Imparting
constructive notice of matters relating to real property to
purchasers for value and without knowledge. With
respect to Section 1(a)(lv) of the Exclusions From
Coverage, 'public records' shall also Include
environmental protection liens flied In the records of the
clerk of the United States district court for the district In
which the land Is located.
g) "unmarketablilty of the title": an alleged or
apparent matter affecting the title to the land, not
excluded or excepted from coverage, which would entitle
a purchaser of the estate or Interest described In Schedule
A to be released from the obligation to purchase by virtue
of a contractual condition requiring the delivery of
marketable title.
2. CONTINUATION OF INSURANCE AFTER
CONVEYANCE OF TITLE.
The coverage of this policy shall continue In force as of
Date of Policy In favor of an Insured only so long as the
insured retains an estate or Interest In the land, or holds
an Indebtedness secured by a purchase money mortgage
given by a purchaser from the Insured, or only so long as
the Insured shall have liability by reason of covenants of
CONDITIONS AND STIPULATIONS
continue In force In favor of any purchaser from the
Insured of either (1) an estate or Interest in the land, or (11)
an Indebtedness secured by a purchase money mortgage
given to the Insured.
3. NOTICE OF CLAIM TO BE GIVEN BY AN
INSURED CLAIMANT.
The Insured shall notify the Company promptly In
writing (1) In case of any litigation as set forth In Section
4(a) below, (11) In case knowledge shall come to an
Insured hereunder of any claim of title or Interest which Is
adverse to the title to the estate or Interest, as Insured,
and which might cause loss or damage for which the
Company may be liable by virtue of this policy, or (111) If
title to the estate or Interest, as Insured, Is rejected as
unmarketable. If prompt notloe shall not be given to the
Company, then as to the Insured all liability of the
Company shall terminate with regard to the matter or
matters for which prompt notice Is required; provided,
however, that failure to notify the Company shall In no
case prejudice the rights of any Insured under this policy
unless the Company shall be prejudiced by the failure and
then only to the extent of the prejudice.
4. DEFENSE AND PROSECUTION OF ACTIONS;
DUTY OF INSURED CLAIMANT TO COOPERATE.
a) Upon written request by the Insured and subject
to the options contained In Section 6 of these Conditions
and Stipulations, the Company, at Its own cost and
without unreasonable delay, shall provide for the defense
of an Insured In litigation In which any third party asserts
a claim adverse to the title or Interest as Insured, but only
as to those stated causes of action alleging a defect, lien
or encumbrance or other matter Insured against by this
policy. The Company shall have the fight to select
counsel of Its choice (subject to the right of the Insured to
object for reasonable cause) to represent the Insured as
to those stated causes of action and shall not be liable for
and will not pay the fees of any other counsel. The
Company will not pay any fees, costs or expenses incurred
by the Insured In the defense of those causes of action
which allege matters not Insured against by this policy.
b) The Company shall have the right, at Its own cost,
to Institute and prosecute any action or proceeding or to
do any other act which In Its opinion may be necessary or
desirable to establish the title to the estate or Interest, as
Insured, or to prevent or reduce loss or damage to the
Insured. The Company may take any appropriate action
under the terms of this policy, whether or not it shall be
liable hereunder, and shall not thereby concede liability or
waive any provlslon of this policy. If the Company shall
exercise its rights under this paragraph, It shall do so
diligently.
c) Whenever the Company shall have brought an
litigation to final determination by a court of competent
jurisdiction and expressly reserves the right, In Its sole
discretion, to appeal from any adverse judgment or order.
d) In all cases where this policy permits or requires
the Company to prosecute or provide for the defense of
any action or proceeding, the Insured shall secure to the
Company the right to so prosecute or provide defense
In the action or proceeding, and all appeals therein, and
permit the Company to use, at its option, the name of the
Insured for this purpose. Whenever requested by the
Company, the Insured, at the Company's expense, shall
give the Company all reasonable aid (1) In any action or
proceeding, securing evidence, obtaining witnesses,
prosecuting or defending the action or proceeding, or
affecting settlement, and (II) In any other lawful act which
In the opinion of the Company may be necessary or
desirable to establish the title to the estate or Interest as
Insured. If the Company Is prejudiced by the failure of
the Insured to furnish the required cooperation, the
Company's obligations to the Insured under the policy
shall terminate, Including any liability or obligation to
defend, prosecute, or continue any litigation, with regard
to the matter or matters requiring such cooperation.
S. PROOF OF LOSS OR DAMAGE.
In addition to and after the notices required under
Section 3 of these Conditions and Stipulations have been
provided the Company, a proof of loss or damage signed
and sworn to by the Insured claimant shall be furnished to
the Company within 90 days after the insured claimant
shall ascertain the facts giving rise to the loss or damage.
The proof of loss or damage shall describe the defect In,
or lien or encumbrance on the title, or other matter
Insured against by this policy which constitutes the basis
of loss or damage and shall state, to the extent possible,
the basis of calculating the amount of the loss or damage.
If the Company is prejudiced by the failure of the Insured
claimant to provide the required proof of loss or damage,
the Company's obligations to the Insured under the policy
shall terminate, Including any liability or obligation to
defend, prosecute, or continue any litigation, with regard
to the matter or matters requiring such proof of loss or
damage.
In addition, the Insured claimant may reasonably be
required to submit to examination under oath by any
authorized representative of the Company and shall
produce for examination, Inspection and copying, at such
reasonable Ltmes and places as may be designated by any
authorized representative of the Company, all records,
books, ledgers, checks, correspondence and memoranda,
whether bearing a date before or after Date of Policy,
which reasonably pertain to the loss or damage. Further,
if requested by any authorized representative of the
Company to examine, Inspect and copy all records, books,
ledgers, checks, correspondence and memoranda In the
cvs;tody or control of a third party, which reasonably
pertain to the loss or damage. All Information designated
as confidential by the Insured claimant provided to the
Company pursuant to this Section shall not be disclosed to
others unless, In the reasonable judgment of the
Company, It Is necessary In the administration of the
claim. Failure of the Insured claimant to submit for
examination under oath, produce other reasonably
requested Information or grant permission to sea re
reasonably necessary Information from third parties as
required In this paragraph shall terminate any liability of
the Company under this policy as to that claim.
6. OPTIONS TO PAY OR OTHERWISE SETTLE
CLAIMS; TERMINATION OF LIABILITY.
In case of a claim under this policy, the Company shall
have the following additional options:
a) To Pay or Tender Payment of the Amount of
Insurance.
1) To pay or tender payment of the amount of
Insurance under this policy together with any costs,
attorneys' fees, and expenses Incurred by the Insured
claimant, which were authorized by the Company, up to
the time of payment or tender of payment and which the
Company Is obligated to pay.
11) Upon the exercise by the Company of this
option, all liability and obligations to the Insured under
this policy, other than to make the payment required,
shall terminate, Including any liability or obligation to
defend, prosecute, or continue any litigation, and the
policy shall be surrendered to the Company for
cancellation.
b) To Pay or Otherwise Settle With Parties Other than
the Insured or With the Insured Claimant
1) to pay or otherwise settle with other parties for
or In the name of an Insured claimant any claim Insured
against under this policy, together with any costs,
attorneys' fees, and expenses Incurred by the Insured
claimant which were authorized by the Company up to the
time of payment and which the Company Is obligated to
pay; or
11) to pay or otherwise settle with the Insured
claimant the loss or damage provided for under this
policy, together with any costs, attorneys' fees, and
expenses Incurred by the Insured claimant which were
authorized by the Company up to the time of payment
and which the Company is obligated to pay.
Upon the exercise by the Company of either of the
options provided for in paragraphs (b)(i) or (II), the
Company's obligations to the Insured under this policy for
the claimed loss or damage, other than the payments
required to be made, shall terminate, Including any
liability or obligation to defend, prosecute or continue any
litigation.
7. DETERMINATION, EXTENT OF LIABILITY AND
COINSURANCE.
This policy Is a contract of Indemnity against actual
monetary loss or damage sustained or Incurred by the
Insured claimant who has suffered loss or damage by
reason of matters Insured against by this policy and only
to the extent herein described.
a) The liability of the Company under this policy shall
not exceed the least of:
1) the Amount of Insurance stated In Schedule A;
or,
II) the difference between the value of the Insured
estate or Interest as Insured and the value of the insured
estate or Interest subject to the defect, lien or
encumbrance Insured against by this policy.
b) (7h/s paragraph dealing with Coinsurance
was removed line Ronda pol/dam)
c) The Company will pay only those costs, attorneys'
fees and expenses Incurred In accordance with Section 4
of these Conditions and Stipulations.
8. APPORTIONMENT.
If the land described In Schedule A consists of two
or more parcels which are not used as a single site, and a
loss is established affecting one or more of the parcels but
not all, the loss shall be computed and settled on a pro
rate basis as If the amount of Insurance under this policy
was dlvlded pro rata as to the value on Date of Policy of
each separate parcel to the whole, exclusive of any
Improvements made subsequent to Date of Policy, unless
it IIahIIIN nr vahre hoc nthenuiaa been agreed upon as to
of the Issuance of this policy and shown by an express
statement or by an endorsement attached to this policy.
9. LIMITATION OF LIABILITY.
a) If the Company establishes the title, or removes the
alleged defect, lien or encumbrance, or cures the lack of a
right of access to or from the land, or cures the claim of
unmarketabllfty of title, all as Insured, In a reasonably
diligent manner by any method, Including litigation and
the completion of any appeals therefrom, It shall have
fully performed Its obligations with respect to that matter
an shall not be liable for any loss or damage caused
thereby.
b) In the event of any litigation, Including litigation by
the Company or with the Company's consent, the
Company shall have no liability for loss or damage until
there has been a final determination by a court of
competent jurisdiction, and disposition of all appeals
therefrom, adverse to the title as Insured.
c) The Company shall not be liable for loss or damage
to any Insured for liability voluntarily assumed by the
Insured In settling any claim or suit without the prior
written consent of the Company.
10. REDUCTION OF INSURANCE; REDUCTION OR
TERMINATION OF LIABILITY.
All payments under this policy, except payments made
for costs, attorneys' fees and expenses, shall reduce the
amount of the insurance pro tanto.
11. LIABILr1Y NONCUMULATIVE.
It Is expressly understood that the amount of Insurance
under this policy shall be reduced by any amount the
Company may pay under any policy Insuring a mortgage
to which exception Is taken In Schedule 8 or to which the
Insured has agreed, assumed, or taken subject, or which
Is hereafter executed by an Insured and which Is a charge
or lien on the estate or Interest described or referred to In
Schedule A, and the amount so paid shall be deemed a
payment under this policy to the Insured owner.
12. PAYMENT OF LOSS.
a) No payment shall be made without producing this
policy for endorsement of the payment unless the policy
has been lost or destroyed, in which case proof of loss or
destruction shall be furnished to the satisfaction of the
Company.
b) When liability and the extent of loss or damage has
been definitely fixed In accordance with these Conditions
and Stipulations, the loss or damage shall be payable
within 30 days thereafter.
13. SUBROGATION UPON PAYMENT OR
SETTLEMENT.
a) The Company's Right of Subrogation.
Whenever the Company shall have settled and paid a
claim under this policy, all right of subrogation shall vest
In the Company unaffected by any ad of the insured
claimant.
The Company shall be subrogated to and be entitled to
all rights and remedies which the Insured claimant would
have had against any person or property In respect to the
claim had this policy riot been Issued. If requested by the
Company, the Insured claimant shall transfer to the
Company all rights and remedies against any person or
Property necessary In order to perfect this right of
subrogatlon. The Insured claimant shall permit the
Company to sue, compromise or settle In the name of the
Insured claimant and to use the name of the Insured
claimant In any transaction or litigation InvoMng these
rights or remedies.
If a payment on account of a claim does not fully cover
the loss of the Insured claimant, the Company shall be
subrogated to these rights and remedies In the proportion
which the Company's payment bears to the whole amount
of the loss.
If loss should result from any act of the Insured
dalmant, as stated above, that act shall not void this
policy, but the Company, In that event, shall be required
to pay only that part of any losses Insured against by this
policy which shall exceed the amount, It any, lost to the
Company by reason of the Impairment by the Insured
claimant of the Company's right of subrogation.
b) The Company's Bights Against Non -Insured
The Company's right of subrogation against non -
Insured obligors shall exist and shall Include, without
limitation, the rights of the Insured to Indemnities,
guaranties, other policies of Insurance or bonds,
notwlthstandlno anv terms or conditions contained In
reason of this policy.
14. ARBITRATION.
Unlew prohibited by appli®bJe law, arbitration
pursuant to the "de Insurance Arbitradon Rukas of
the Amertcan Arbitration Association may be
demanded if agreed to by both the Company and
the lnsure+d. Arbitrable matters may indude, but
en not limited to, any controversy or daim
between the Company and the Insured arising out
of or m&t0ng to this policy, and service of the
Company In connection with itr Issuance or the
breach of a polky pmvWon or other obllyadon.
Arbitatlon pursuant to this poky and under the
Rules; in effect on the date the demand 1br
arbitration Is made or, at the option of the lnsura4
the Ruk v In effect at Dade of egolky shell be
b/ndlny upon the perdeA the award may include
attorneys' Bees only if the laws of the state in
which the land is located permit a court to award
attorneys' fees to a prevalUng prrty. Judgment
Upon the award rendered by the Arblbator(s) may
be entered In any court havingiurisdicdon thereof.
The law of the sltus of the land shall apply to an
arbitration under the Title Insurance Arbitrations Rules.
A copy of the Rules may be obtained from the
Company upon request.
15. LIABILITY LIMITED TO THIS POLICY; POLICY
ENTIRE CONTRACT.
a) This policy together with all endorsements, It any,
attached hereto by the Company is the entire policy and
contract between the Insured and the Company. In
Interpreting any provision of this policy, this policy shall be
construed as a whole.
b) Any claim of loss or damage, whether or not based
on negligence, and which arises out of the status of the
title to the estate or Interest covered hereby or by any
action asserting such daim, shall be restricted to this
policy.
c) No amendment of or endorsement to this policy can
be made except by a writing endorsed hereon or attached
hereto signed by either the President, a Moe President,
the Secretary, an Assistant Secretary, or validating officer
or authorized signatory of the Company.
16. SEVERABILIiY.
In the event any pmvlslon of the policy Is held Invalid
or unenforceable under applicable law, the policy shall be
deemed not to Include that provision and all other
provisions shall remain In full force and effect
17. NOTICES, WHERE SENT.
All notioes required to be given the Company and any
statement In writing required to be fumes the
Company shall Include the number of this policy and shall
be addressed to the Company, Attention: Claims
Department, 1 First American Way, Santa Ana, California
92707.
M
f.DCS '""' Siti...actEtK.:iY,s..ti t.flt35i•'-,s"..ter..r TA:r-a:.aJ,ic l^L.YdaT,"a:.czf!r`52R.r,79:f l5oc.•. _.:7 IMri:S,.•+•R IIF'Yra:,aurr,oKa! J'iiQuR.w•.
A
First American Title Insurance Company
11
r ,= 11 E I,ys ',
SUTEMBEA 24, a S
195E
i..ak•.,,fLtt•iN'%r;1a;. I
Prepared by
Holly Allison, an employee of
First American Title Insurance Company
870 Sun Drive, Suite 1072
Lake Mary, Florida 32746
407) 321-5449
Return to: Grantee
File No.: 2022-432441-0716
WARRANTY DEED
This indenture made on February 17, 2004 A.D., by
Dove Builders of Central Florida, Inc.
whose address Is: ,
hereinafter called the "grantor", to
James A. Blagg and Paula K. Blagg
whose address is: Lot 142, Sanford, FL 32771
hereinafter called the "grantee":
which terms 'Grantor" and "Grantee" shall include singular or plural, corporation or Individual, and either sex, and shall include heirs, legal
representatives, successors and assigns of the same)
Witnesseth, that the grantor, for and in consideration of the sum of Ten Dollars, ($10.00) and other
valuable considerations, receipt whereof is hereby acknowledged, hereby grants, bargains, sells, aliens,
remises, releases, conveys and confirms unto the grantee, all that certain land situate in
Seminole County, Florida, to -wit:
Lot 142 of "SANFORD HEIGHTS" ADDITION to Sanford, according to the Plat thereof as
recorded in Plat Book 2, Page(s) 63, of the Public Records of Seminole County, Florida.
Parcel Identification Number: 36-19-30-506-0000-1420
Subject to all reservations, covenants, conditions, restrictions and easements of record and to all
applicable zoning ordinances and/or restrictions imposed by governmental authorities, if any.
Together with all the tenements, hereditaments and appurtenances thereto belonging or in any way
appertaining.
To Have and to Hold, the same in fee simple forever.
Page 1 of 2
2022 - 432441
And the grantor hereby covenants with said grantee that the grantor is lawfully seized of said land in fee
simple; that the grantor has good right and lawful authority to sell and convey said land; that the grantor
hereby fully warrants the title to said land and will defend the same against the lawful claims of all
persons whomsoever; and that said land is free of all encumbrances except taxes accruing subsequent to
December 31st of 2003.
In Witness Whereof, the grantor has hereunto set their hand(s) and seal(s) the day and year first
above written.
Dove Builders of
Central Florida,
Inc.
Signed, sealed and delivered in our presence:
Witness Signature
Print Name:
State of Florida
County of Seminole
Witness Signature
Print Name:
The Foregoing Instrument Was Acknowledged before me on February 17, 2004, by Dove
Builders of Central Florida, Inc. who is/are personally known to me or who has/have produced a
valid driver's license as Identification.
NOTARY PUBLIC
Notary Print Name
My Commission Expires:
Page 2 of 2
2022 - 432441
DEVELOPMENT FEE WORKSHEET
CITY OF SANFORD
UTILITY — ADMIN
P.O. BOX 1788
SANFOR/D, FL 32772-1788
Project Name: Date y/Y
Owner/Contact Person:
Address: 217
Type of Development:
1) RESIDENTIAL
Phone:
Type of Units (single family
or multi -family):
Total Number of Units: 3 f3E "
Type of Utility Connection
individual connections
or central water meter &
common sewer tap):
Water Meter Size (3/4",
y
1 ", 201, etc.): f
REMARKS:
2) N N-RESIDENTIAL
Type of Units (commercial,
Industrial, etc.):
1
Total Number of Buildings:
Number of Fixture Units
each building):
Type of Utility Connection
individual connections
or central water meter &
common sewer tap):
Water Meter Size (3/4",
1" 2" ,etc.) ,
REMARKS:
cmn
CONNECTIONFEE CALCULATION.it.+JL170 a, O A."
7 /, /'04/J/.tcr A.1.5-p 0% A
TAB dr 44 3 tl/
G/f/L py f5 G poo. 00 Name -
Signature - Dat Ile
1) Water Svstem Impact Fees
Equivalent Residential Connection (ERC) -300 Gallons-PerDay (GPD) Residential
S65WUnit -
Single family structure, or multi -family unit containing
three (3) bedrooms or more. . S487.
50/Unit - Multi -family unit or Mobile Home unit containing less
than three (3) bedrooms. (Ibis category is based
on judgment/anumption, estimation that such
family units on average require 75%P-225 GPD of
the water and sewer service of an average single family
unit} Commercial
S650/
ERU - Fixtures unit schedule from Southern Plumbing Code Will
be used. One ERU will be charged for connection and
up to twenty (20) fixtures units. For
projects having more that twenty (20) fixture unit base
for the first ERU. (Example: twenty-five (25) fixtures
units will be rated as 1.25 eru: twenty-six (26) fixture
units will be rated as 1.5 ERU.) 2)
Sewer Systems impact Fees Equivalent
Residential Connectibns-270' Gallons Per Day (GPD) Residential -
S1,
700 Unit - Single Family structure, or multi -family unit Containing
three (3) bedrooms or more. S1,
275/Unit - Multi -family unit or Mobile Home unit containing less
than three (3) bedrooms. (Ibis category is based on judgment/
assumption, estimation that such family units on average
require 75% of water and sewer service of an. average
single family unit Commercial -
Industrial- Institutional S
1,700/ERU Fixtures
unit schedule from Southern Plumbing Code will
be used. One ERU will be charged for connection and up to twenty (
20) fixtures units For projects having more than twenty 20)
units the Impact fee will be increments of 25% based on multiples
of five (5) fixture units above the twenty (20) fixture unit
base for the Cast ERU. (Example: twenty five (25) fixture units will' be
rated as 1.25 ERU: twenty six (26) fixture units will be rated as 1.5 ER14 FIXTURES
TYPE DRAINAGE FIXTURES UNIT VALVE
AS LOAD FACTORS MINIMUM
SIZE OF TRAP(
INCHES) Automatic
clothes washers, commercial a 3 2 Automatic
clothes washers, residential 2 2 Bathroom
group consisting of water closets, lavatory, bidet
and bathtub or showers 6
Bathtub (
b) (with or without overhead shower or whirlpool
at hments)' 2
1 '/2 Bidet
2 1 '/4 Combination
sink and tray 2 1 '/2 Dental
lavatory 1 1 'A Dental
unit or cuspidor 1 1 ''A Dishwashing
machine, (c )domestic 2 1 '/2 Drinking
fountain 2 1 '/4 Floor
drains 2 2 Kitchen
sink domestic 2 1 M Kitchen
sink, domestic with food waste grinder and/or Dishwasher
2
1 '/2 Laundry
tray 1 or"2 coin ents 2 1 '/ Lavatory
1 1 'A Shower
comDartments. domestic 2 2 Sink
2 1 Urinal
4 Footnote d Urinal,
1 gallon per flush or less 2e Footnote d Wash
sink (circular or multiple) each ser of faucets 2 1 y, Water
closets, flushometer tank, public or private 4e Footnote d Water
clo, ts, private installation 4 Footnote d Water
closets, public installation 6 Footnote d For
SI: 1 hwh-25.4 min, I gallorr3.795 L a
For traps larger than 3 inches, use Table 709.2 b
A showerhead over a bathtub or whirlpool bathtub attachments does not increase the drainage fixttaes unit valve e
See sections 709.2 thought 709.4 for methods of computing unit vatve of fixtures pat listed in Table 709.1 or for ruing of devices with intermittent flows.• d
Trap size shall be consistent with the fixtures outlet size. - e
For the purpose of computing loads on building drains and sewers, water closets or urinals shall not be rated at a lower drainage first fixture unit unless
the lower values are confirmed by testing. TABLE 709.2 DRAINAGE FIXTURES UNITS FOR FIXTURES DRAINS OR TRAPS Fixture
Dram or Trap Size
inches Drainage
Fixtures Unit
Value 1 '
A 1 1%
2 2
3 2%
4 3
5 4
6 Standard
Plumbing cod" 0 1997