Loading...
HomeMy WebLinkAbout124 Venetian Bay Cir 04-1887 New SFH4 o WHILE EVERY ATTEMPT HAS BEEN MADE TO PREVENT HUMAN ERROR, CONTRACTORS, SUB -CONTRACTORS AND BUILDERS ARE URGED TO REVIEW ALL INFORMATION CONTAINED HEREIN PRIOR TO COMMENCEMENT OF CONSTRUCTION. BEAUMONT a ASSOCIATES, INC. IS NOT RESPONSIBLE FOR ANY MISINTERPRETATIONS, ERRORS, OMISSIONS OR CUSTOM CHANGES MISSED AND NOT REPORTED TO BEAUMONT d ASSOCIATES, INC. PRIOR TO CONSTRUCTION. NO EXCEPTIONS. N m 0 . N 0 GENERAL NOTES DESIGN REQUIREMENTS I. DESIGN LIVE LOADS(MINIMUM): A) FLOORS - 40 PSF B) DECKS - 40 PSF C) STAIRS - 40 PSF D) ROOFS W/SLOPE 4" TO 12" PER FOOT - 1(c P5F E) ROOFS W/SLOPE LESS THAN 4" PER FOOT - 20 PSF WIND DESIGN LOAD INFORMATION - (PER FBC CHAPTER 1(a SECTION 1606.1.1, REF. ASCE 1=98 CHAPTER 6) 1. BASIC WIND SPEED = 120 MPH(3 SECOND GUST) 2. WIND IMPORTANCE FACTOR = 1.00 (ACSE 1-90, TABLE 6-1, PG.55) BUILDING CATEGORY = II (A5CE =95, TABLE 1=1, PG.4) 3. WIND EXPOSURE(ALL SIDES) =B (ASCE =9�, SECTION 6.5.6, PG.2,5) 4. INTERNAL PRESSURE COEFFICIENT5(A5CE 1-98, TABLE 6-7, PG.6 2) ENCLOSED BUILDINGS = ±0.la PARTIALLY ENCLOSED BUILDINGS (NOTE: COEFFICIENTS FOR PARTIALLY ENCLOSED STRUCTURES ARE APPLIED WHEN DESIGN OF MEMBERS) FALLS UNDER ASCE 1-9a DEFINITIONS CLASSIFYING AS SUCH) �. ALL COMPONENTS AND CLADDING NOT SPECIFIED ON PLANS SHALL BE DESIGNED TO WITHSTAND THE FOLLOWING PRESSURES: FOR WALL LOCATIONS: -35 P5F, +26 FSF FOR. ROOF LOCATIONS: =45 PSF, +14 PSF (ACSE 1-95, TABLE 6-3A, PG.51) FOUNDATIONS 1. SOIL TO BE COMPACTED TO AT LEAST 95% UNDER SLABS AND eb% UNDER FOOTINGS OF MAX. DRY DENSITY AS DETERMINED BY A5TM- ISE�1 (MODIFIED PROCTOR) 2. LAP VAPOR BARRIER JOINTS 4" AND CONTINOUSLY TAPE SEAMS 3. FOUNDATIONS AND FOOTINGS ARE DESIGNED FOR AN ALLOWABLE SOIL BEARING OF 2000 PSF r 7 Model 1614 T F D H OVER VB-51 CAST IN PLACE CONCRETE 1. ALL CONCRETE SHALL HAVE A MINIMUM COMPRE551VE STRENGTH AT 25 DAYS OF 2500 PSI, A SLUMP OF 4" PLUS OR MINUS I", AND HAVE 2 TO 4`o AIR ENTRAINMENT, AND A MAXIMUM WATER/CEMENT RATIO OF 0.58, 2. ALL REINFORCING STEEL SHALL BE NEW DOMESTIC DEFORMED BILLET STEEL CONFORMING TO ASTM A-615 GRADE 40. 3. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A -lay FOR 6X6XUJI.4xW].4 WWF SHALL BE LAPPED AT LEAST 6" & CONTAIN AT LEAST ONE CROSS WIRE WITHIN THE 6", FIBERMIX OF EQUAL SPECIFICATIONS MAY BE USED IN LIEU OF WWF. 4. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH "THE BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE" ACI 318 LATEST EDITION, AND "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS," ACI 301, 5. HORIZONTAL FOOTING BARS SHALL BE BENT MIN. 12 BAR DIAMETERS (EXCLUDING B€ND) AROUND CORNERS OR CORNER BARS WITH MIN. 12'' LAP EXCLUDING BEND AT EACH END SHALL BE PROVIDED, 0. MINIMUM LAP 6PLICE5 ON ALL REINFORCING BARS SHALL BE 40 BAR DIAMETERS. BOLTS AND THREADED RODS 1, ALL 5OLT5 8 THREADED RODS TO BE ASTM 4301 OR BETTER(U.N.O.) MASONRY WALL CONSTRUCTION 1. HOLLOW LOAD BEARING UNITS SHALL BE NORMAL WEIGHT, GRADE N, TYPE 2, CONFORMING TO ASTM C90, WITH A MINIMUM NET COMPRESSIVE STRENGTH OF 2000 PSI (f'm = 1900 PSI) 2. MORTAR SHALL BE TYPE M OR 5, CONFORMING TO ASTM C210. 3. HEAD MORTAR JOINTS AT PRECAST WINDOW SILLS TO BE NO MORE THAN 1" MASONRY WALL CONSTRUCTION (CONT.) 4. COARSE GROUT SMALL CONFORM TO ASTM C416 WITH A MAXIMUM AGGREGATE 51ZE OF 3/S" AND A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI. E5. VERTICAL REINFORCEMENT SHALL BE AS NOTED ON THE DRAWING5 WITH CELLS FILLED WITH. COARSE GROUT. 6. VERTICAL REINFORCEMENT SHALL BE HELD IN POSITION AT THE TOP AND BOTTOM AND AT A MAXIMUM SPACING OF V-0" U.N.O. REINFORCEMENT SHALL BE PLACED IN THE CENTER OF THE MASONRY CELL TYPICAL UNLESS OTPERW15E NOTED. 1, REINFORCING STEEL 5HALL BE LAPPED MINIMUM 30" UNLESS NOTED CTHERW15E ON THE DRAWINGS. 0. NOOKS AT TOP 4 BOTTOM OF VERTICAL REINFORCING BARS TO BOND COARSE AND FOOTING TO BE NO LESS THAN 12 BAR DIAMETERS EXCLUDING BEND S. EXPANSION TYPE ANCHORS ARE NOT TO BE USED IN BOND COURSE. EMBEDDED ANCHORS OR €FOXY FASTENED STUDS SHALL BE USED. WOOD CONSTRUCTION 1, WOOD CONSTRUCTION SHALL CONFORM TO THE NFPA "NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION", LATEST EDITION.(NDS) 2. ALL EXTERIOR WOOD STUD WALLS, BEARING WALLS. SHEAR WALLS AND MISC. STRUCTURAL WOOD FRAMING MEMBERS. (1,E. BLOCKING OR GABLE END BRACING), SHALL BE SOUTHERN YELLOW PINE OR EQUIVALENT. NO. 2 GRADE SHALL BE USED REGARDLESS OF SPECIES. 3. TOP AND BOTTOM PLATES OF LOAD BEARING WALLS MUST BE SOUTHERN YELLOW PINE NO. 2 OR EQUIV. r 7" �; FF. ' REDRAW REVISIONS TO MASTER T REDUCE GARAGE E ),' INCHES GLASS ENTRY DOOR. POCKET DOOR BETWEEN MASTR 5ATH 5EDROOM L1- PRE -FABRICATED WOOD TRUSSES 1. ALL PREFABRICATED WOOD TRUSSES SMALL BE SECURELY FASTENED TO THEIR SUPPORTING WALLS OR BEAMS WITH HURRICANE CLIPS OR ANCHORS. 2, TRUSSES SHALL BE DESIGNED BY MWFRS METHODOLOGY FOR LONG SPAN TRUSSES TO DETERMINE UPLIFT AND REACTION VALUES. MEMBER AND PLATE DESIGN TO BE CALCULATED BY COMPONENTS AND CLADDING METHOD UNLESS SPECIFIED OTH€RW15€ BY TRUSS ENGINEER OF RECORD 3. PREFABRICATED WOOD TRUSSES SHALL BE DESIGNED IN ACCORDANCE WITH THE LATEST EDITION OF THE 4. ''NATIONAL DESIGN SPECIFICATION FOR 5TRES5=GRADE LUMBER AND ITS FASTENERS" AS RECOMMENDED BY THE NATIONAL FOREST PRODUCTS ASSOCIATION, 5. TRUSS MEMBERS AND CONNECTIONS SHALL BE PROPORTIONED (WITH A MAXIMUM ALLOWABLE STRESS, INCREASE FOR LOAD DURATION OF 25%) TO WITHSTAND THE LIVE LOADS GIVEN IN THE NOTES AND TOTAL DEAD LOAD. 6. BRIDGING FOR PRE=ENGINEERED TRUSSES SMALL BE AS REQUIRED BY TRUSS MANUFACTURER UNLESS NOTED ON PLANS. 1. TRUSS ELEVATIONS AND SECTIONS ARE FOR GENERAL CONFIGURATION OF TRU55E5 ONLY. WEB MEMBERS ARE NOT SHOWN, BUT SHALL BE DESIGNED BY TRUSS MANUFACTURER IN ACCORDANCE WITH THE DESIGN LOADS. TRUSS DESIGN LOADS : TOP CHORD : LL = 20 PSF DL = 10 PSF(SHINGLE TYPE ROOF COVER) DL = 14 PSF AT OVERBUILT BOTTOM CHORD : DL = 10 PSF WIND LOAD : SEE DESIGN REQUIREMENTS (TRUSS MNF. MAY TAKE REDUCTION FOR 6:12 SLOPES OR GREATER) 4 PRE -FABRICATED WOOD TRUSSES (CONT.) 0. THE TRUSS MANUFACTURER SHALL DETERMINE ALL SPANS, WORKING POINTS, BEARING POINTS, AND 51MILAR CONDITIONS. TRUSS 514OF DRAWINGS SHALL SHOW ALL TRUSSES, ALL BRACING MEMBERS, AND ALL TRUSS TO TRUSS HANGERS. 9. PROVIDE ADDITIONAL BRACING AND BLOCKING PER HIB-91 AND TRUSS MANUFACTURER'S DRAWINGS FIELD REPAIR NOTES I. DRILL A 3/4" DIAMETER HOLE MIN. 6" DEEP AT THE LOCATION OF THE OMITTED REBAR, AND INSTALL NO. �, BAR INTO EPDXY FILLED HOLE EPDXY TO BE SIMPSON STRONG TIE EPDXY OR EQUIVILENT. FOLLOW MANUFACTURE'S INSTRUCTIONS. ASSURE THAT ALL DUST AND DEBRIS FROM DRILLING ARE REMOVED FROM HOLE BY USING COMPRESSED AIR PRIOR TO APPLYING EPDXY. ALLOW EPDXY TO CURE TO MANUFACTURER'S SPECIFICATIONS, THEN FILL CELL IN THE NORMAL WAY DURING BONDBEAM POUR. USE 30" MIN. LAP SPLICE. HOOKS AT TOP OF BAR TO BE MIN, 12 BAR DIAMETERS(EXCLUDING BEND), 2. MAY SUBSTITUTE 5TRAP5/CONNECTOR5 w/5TRAF5/CONNECTOR5 OF EQUAL OR GREATER UPLIFT & LATERAL RESISTANCE VALUES IN FIELD WITHOUT VERIFICATION, PROVIDED ALL MANUFACTURES INSTALLATION INSTRUCTIONS ARE FOLLOWED. 3. FOR MORTER JOINTS LESS THAN 1/411, PROVIDE (1)#5 VERT, IN CONC, FILLED CELL EA. SIDE OF JOINT(BAR DOES NOT HAVE TO BE CONT. TO FTG.) 4. 2XITS MAY BE USED ILO TIMBERSTRANDS FOR STAIR STRINGERS S. RIM BOARDS MAY BE USED FOR R15ER5 & TREADS ILO 2xl2'5 6. WOOD STUDS MAY BE SUBSTITUTED OF METAL 5TUD5 IN NON -LOAD BEARING WALLS I. MISSED META=16 LINTEL STRAPS FOR MASONRY CONSTRUCTION MAY BE REPLACED w/ 51MP50N MTSM16 TWIST STRAP(S) w/ (1) 10d 0 TRUSS d (4) 1/4 x 2 1/4 TAFCONS e CMU EACH. USE (1) FOR UPLIFTS OF a40 1-155. OR LESS. USE (2) FOR UPLIFTS OF 041 LBS. TO 1000 L55. OTHERS ON CASE BY CASE BASIS TO BE APPROVED BY ENGINEER OF RECORD. V � � I I O O 0' ® Q a +A X W z W 2 � z 0 +j Ei w Q ® WQ � vi 0: A O O w 0 cqd cn U O N Z O r\ F- U 0 0 0 Ix w WP W� N � aA ME W •�' wC4 ROBERT M. MONTA, P.E 3w U W� N 2 U� 2� 3� i O Ww MR am X_, D n w Q: E+ O�W F- V1 Q J� QA zw 2.� L� 00 N WW 20 C L ~U 00 z 0 0 Id 2.4 1a Ua 00 FI- W 004 cf) � F- w� W m� Q F-o 0 acn WE2 O 0 .�H F- A 2� WO LEC011 as O U a+ W W > m� w� W m� Um z E+ vi w a U O V) a F- z 0 2 D a w m 0 �, Ill b N F- 2 O U C� u _ _ m 2'-411 5'-10" 71-0" 5'-1011 5 pl 24" x 24'' x 12'1w(3)11S'5 EAC�4 WAY DEEP DI NS - r - J I r------- ------- ---------'�-, L PLR FIN. PER 14 /a" 11 2 -7 I I 1 DI i j I I 1 3/4' RECESSED SILL I SLID NG GLASS DOOR I _ I I� I I •I � II I cal u ' u I 11 — 1 sHUJR - T UB �I I Li) TILE L�. (CDAV,R — 11 TUB 2' -10"01 N N I Nr DwC I I I A II rl o _.» I II Nis ANu I 6) .1 FIN. FLOOR LINE IN SLAB FOR ICE MAKER LINE I 1 !!! I 1 — PT. \\ \ I w I I c0 \\ 1 4" DIA. SCN 40 I 3 DI r I I 15 PYC CHASE IN SLAD FOR A/C 1 �n 'IT F _1 ...�_._._.. OWH — —_..I... al I 1 IN. FLOOR I �' = 0" I 11'=a" I I 1 3/v "X42 "\4�� 2'-a" 4'-a" 2' 8'! 14 i 1 1 CONC.A 1 PE;l — 1 FIN. FLOOR 1 1 1'-4" 1 I = 24" x 24" x 12" Di=1=P - CONC. FOOTING w/ I I I 1 I Q 3 #5 54RS EA. WAY 1 I I IS r 1 I SLOPE I DI 1 i I/8" PER r-T. 1 I N.B. 1 I I I FIN. FLOOR 16 D2 1 I 1 �T---------- ---- ----� h 16 13 (2) � — D2 DI 2'-011 10'-0" 5'-0" Ilk 20'-0" jk 35'-0'I FOUNDATION PLAN 'A' 'B' 'G' 'D' 2'-011 (2) #5 1/4" = 1'-011 2 U B.T. 3/4 "C;W,HW BATH LAV. L A V. �NIUR 1/2 "GUJ,NU1 W.G. 1/2 "cW,HW BATH T. A V. W.C. 1/2 "CW,HW L.T. LAUNDRY KITCHEN 3/4" wHW WASHER D.UJ. K.S. 3/4 "CW HW 3/4 "CW,HW 3/4 "cW1 To I/2 `CW,H METER PDX 3/4 "GUJ,HW ��a "cW NOTE: DIAGRAMS FOR EA. UNIT ARE SIMILAR EXCEP-1- WHERE NOTED WATER PLUMBING RISER DIAGRAM NEATER NO SCALE TO CITY SEWER C � � I O O W H ct •V � � 2 �i a, °� O 0-4 HO a a w� LAI Z� 0 "•mow Q ®w o W a' a � _ U o � f/j � cCf O co G�2 F- U O m a w ix ch W a xa ap w wPA ROBERT M. MONTA, P.E 3w U W �' U pp SW 3r 0 w U , iz J Q ZW 2,4 IX Q 00 w_w O ~ U 00 � W z 0 o W -4 ON U 00 Q� w W � c--I w O LO 0 a F— q � F- H F-�--I wo cQ 0 O� Q�u) w H O a� E" H A 2� Ucn (w W m rJ wp (AN w jxcn V O LO co O 0 I co �'CQ� o m x x 0 z� ro u __ m FLOOR FLAN IA I, I51/ IG I / IID I WHILE EVERY ATTEMPT HAS BEEN MADE TO PREVENT HUMAN ERROR, CONTRACTORS, SUB -CONTRACTORS AND 5UILDER5 ARE URGED TO REVIEW ALL INFORMATION CONTAINED HEREIN PRIOR TO COMMENCEMENT OF CONSTRUCTION. BEAUMONT 4 ASSOCIATES, INC. IS NOT RESPONSIBLE FOR ANY MISINTERPRETATIONS, ERRORS, OMISSIONS OR CUSTOM CHANCsES MISSED AND NOT REPORTED TO 5EAUMONT 4 ASSOCIATES, INC. PRIOR TO CONSTRUCTION. NO EXCEPTIONS. 35'-O" inn /_II /_I 11 II 1/4 11 O 11-011 DENOTES OPENING SURFACE WINDOW SQ. FT. AREA AND DESIGN PRE55URES +PSF A (P5F) TYf-. 0 DOOR 5GHF.DULt O KNI WIOTH HEI6HT THICKNESS COMMENTS 15'-O"6'-8"15/4"6 PANEL DOUBLE METAL ENTR 2 16'-O" " =i'—O ------ O\/ERHEAD GARAGE DOOR TYPE LIGHTS GLASS HD. H6T. EL;CK DIMENSIONS 151411 EXT. GLASS ENTRY W/ 12" S.L. A C-1/2-35 SEE ELEV. CLEAR SEE ELEV. 21 1/4"X63" 4 ------ TRIPLE SLIDING GLASS DOOR B C-1/2-35 SEE ELEV. CLEAR SEE ELEV. 21 1/4" X 63" W/ BOWTOP 5 2'-3" 6'-P" 1 5/4" FIRE DOOR C C-25 SEE ELEV. CLEAR SEE ELEV. 31 3/4"X63" 6 1 1/2" H.G. INTERIOR D C-25 5EE ELEV. CLEAR SEE ELEV. 3 3/ Xro3 -7 2'-6" 6'-8" 1 1/2" H.G. INTERIOR E MC-25 SEE ELEV. CLEAR 8'=0" 743/4"Xro3" 1 1/2" H.G. INTERIOR F C-34 SEE ELEV. BSC/TEM g _0 531/8'X50�/8 1 1/2" FIRE DOOR TRANS FIXED CLEAR 9'-2" 50" X 16" 10 5'-0" 6'-8" 1" NOM. BI-FOLD H C=25 EE ELEV. CLEAR SEE ELEV. 31 3/4"X63" 11 4'-0" 6'-8" 1" NOM. BI-FOLD I TRANS FIXED CLEAR 9'-2" 50" X 14'' 12 2'-0" 1" NOM. 51-FOLD U TRANS FIXED CLEAR 9'-2° 50" X 14" W/ BOWTOP [14 ------ POCKET 2'-6" 6'-6" I" NOM. BI-FOLD 15 (2) 2'-6" 6'-a" 1 5/4" DBL. FRENGH DOORS 16 2'-8" 6'-8" 1 5/4" EXTERIOR MTL. W/ WINDOW I� 2'-4" 6'-8" 1 1/2" H.G. INTERIOR 18 1'-6" 6'-8" 1 1/8" H.G. INTERIOR Iq 6'-0" 6'-5" I" NOM. BI-FOLD 20 12'-0" 8'-O" ------ TRIPLE SLIDING GLASS DOOR 21 q'-0" 5'-0" ------ 5-(PANEL FRENGH DOOR 22 8'-O" " 5'-0 ------ SLIDING GLASS DOOR 25 61-0" a'-O" ------ PAIR FRENGH DOORa 24 5'-6" 8'-0" ------ FRENGH DOOR 25 6'-O" 8'-0" ------ SLIDING GLASS DOOR 26 5'-0" 8'-0" ------ SLIDING GLASS DOOR GENERAL NOTES. ].ALL EXTERIOR WALL SHALL ASSUMED TO BE LOAD BEARING. SEE FLOOR PLAN AND FOUNDATION PLAN FOR C,M,U, WALL REINFORCEMENT LOCATIONS. 2. WINDOW AND DOOR SUPPLIERS SHALL CURRENT ROUGH OPENING INFORMATION WHICH SHALL HAVE PRECEDENCE OVER THE WINDOW AND DOOR SHEDULES ON PLANS. 3. CABINET MANUFACTURER SHOP DRAWINGS SHALL HAVE PRECEDENCE OVER THE INTERIOR CABINET ELEVATIONS SHOWN ON PLANS, 4, DO NOT SCALE PLANS. DIMENSIONS ARE TO BE FOLLOWED AS NOTED. 5. ALL GLASS LOCATED IN HAZARDOUS LOCATIONS SHALL COMPLY WITH SECTION 2405.2.1 OF THE FLORIDA BUILDING CODE 2001 EDITION. 6. ALL GARAGE/OVER HEAD DOORS SHALL BE LISTED AND TESTED FOR 30 SECONDS AT DESIGN PR5,5URE(+/-) TO INCLUDE A 10 SECOND GUST AT 1.5 TIMES THE DESIGN PRESSURE, 1. MOISTURE BARRIER: ALL EXTERIOR WALLS TO HAVE APPROVED MOISTURE BARRIER NOT LESS THAN NO. 15 FELT, KRAFT WATER PROOF COVERING, TYVEK (OR EaJ, OR PAPER BACKED MTL LATH FOR STUCCO. APPLY WITH A MINIMUM OF 6" VERTICAL LAP (UPPER LEVER OVER LOWER LEVEL) AT VERTICAL JOINTS. FASTEN PER MAN. SPECS, LEGEND INDICATES Oxaxl6 (NOM.) C.M.U. (EXTERIOR LOAD BEARING ). 12'=0" TOP OF CMU INDICATES Sx,5x16 (NOM.) G.M.U. (EXTERIOR LOAD BEARING ). 10'-0" TOP OF CMU INDICATES 8xax16 (NOM.) C.M.U. (EXTERIOR LOAD BEARING ), V-4" TOP OF CMU INDICATES 8xax16 (NOM.) C.M.U, (EXTERIOR LOAD BEARING ). 0'=0" TOP OF CMU INDICATES WALLS TO BE UTILIZED FOR TRUSS BEARING 2x4 WOOD STUDS ,v 16" O.C. U.N.O. INDICATES 25 GA. MTL. STUDS 24" O.C: MAX. (NON LOAD BEARING INTERIOR PARTITIONS ONLY.) (U.N.O.) INDICATES FILLED CELL WITH (1) VERTICAL #5 GROUTED SOLID, (U.N.O.) BAR TO BE CONT, BOND COURSE TO FOOTING, REFER TO COVER SHEET FOR SPLICE AND BEND REQ. ARr-A TAE3ULATION UNDER A/C GARAGE COVERED ENTRY COVERED PORCH fro14 5Q. FT. 422 SQ. FT. 52 SQ. FT. 114 SQ. FT. TOTAL SQUARE FEET 2202 SQ. FT LINEAR FT CALL. MAIN HOUSE (o2'-5" LINEAR FT. OF V-0" BLOCK MAIN HOUSE 152'-211 LINEAR FT. OF 9'-4" BLOCK PATIO 23'-4" LINEAR FT. OF 9'-4" BLOCK TOTALS 1-15' -6 LINEAR FT. OF 9' - 4" BLOCK D15L. 2x12 HEADER ABOVE COLUMN (2)lGd NAILS e 12" o.c. 5M. TO 2x4 FRAMING NOTE: RUN -1/1/o" 055 SHEATHING FROM EXT. TOP OF BEAM TO TBOTTOM OF FRAMING CONT. NAILED PER SCHEDULE. 1 ENTRY SECTION W.W. 7 " = - 11 IT PAP OUT OFENING5 WITH 2X45 EA. SIDE. FASTEN TO MASONRY llt"X3" TAPCONS EVERY 6" O.C. - ELEVATION YIEUIED FROM EXTERIOR O8A1'FRONT WINDOW DtL PLAN VIEW 1/411_11-011 1/211=11_011 co cat V Lco co H � � o� 00 4-J �+ ct 0 a � 04 W Q Ld w 2 (7) a� 0 4-J ' w Ei Q ®wQ �v1 a A -4 O 0 w n U O ^ Z O C F- U o O a a w a � Ix A /y a w wa ROBERT M. MONTA, P.E 3W U )-Cn w 2�F- S U p To 3 t! I a� O w ww w am a� n. W aH O�w VQ�-I J t-I QA Zw 6-4 0�o 00 N ww =o c 1 00 � W z 0 o -4 DOa 00 o W �a o a v) H r--I F, F- Ld r a� FW �01 Ix Ix acn LIE 2 H 0 ,�F F-A 2:z U� �-w aA O O� L w � U Wp to o W acn cn Zm E-i w _Q U O N W Q "Am O„ d N 0 U >� 'd v) 2 U a O 0 3 0 u Z w k 0 i ,II WHILE EV o o CONTRAC REVIEW N OF CONS' N FOR ANY MISS�PII< CONSTRU N O V � � I 00 4 J da W ct U a W cat Q OU H P z W rn cat � O w Q Q ® W co a A -4 o o w U O Z O 7D --� H U O 0 O a a w a," 0 U � wp Qcn jLcn W� aA w wa ROBERT M. MONTA, P.E 3� F oal wu N0 J� QA ZW 2-4 a0 O� ww Io V 1 00 � W w z o Ua 00 o�44 ww � r � w V)0 F-w 2'"q O a MCI) I W� H O O ,� E-+ F- z 0 Q W m cq O +, b O p x q H 2 U a } a O U r� T- k Oi-F -RI -c vE 5HING RO V-4" AF 70P OF T T eI ARCHITECTURA FINIS LEFT SIDE ELEVATION 1/e11 _ 1-0 WHILE EVERY ATTEMPT HAS BEEN MADE TO PREVENT HUMAN ERROR, CONTRACTORS, SUB -CONTRACTORS AND BUILDERS ARE UR3ED TO REVIEW,ALL INFORMATION CONTAINED HEREIN PRIOR TO COMMENCEMENT OF CONSTRUCTION, REAUMONT 4 ASSOCIATES, INC. IS NOT RESPONSIBLE FOR ANY MISINTERPRETATIONS, ERRORS, OMISSIONS OR CUSTOM CHANGES MISSED AND NOT REPORTED TO 13EAUMONT 4 ASSOCIATES, INC. PRIOR TO CONSTRUCTION. NO EXCEPTIONS. a° RAISED sTucco BAND z 5HINGLE ROOF 6 SCORED STUCCO IT-O" AFF. r DETAIL A ENTRY o ii-oll CRICKET 2x6 SUB -FASCIA W/ ALUM. WFIAP AND DRIP EDGE i (TYPICAL) AFF. - Y— _ +I' TOP OF TIE Bl" I. Ll ol JIT❑❑❑❑El❑❑ YP. (TYPJ SCORED BANpING SCORED BANDING �r ARCHITECTURAL T FINIS" 1:1 El El D I I cal _ -- ❑ ❑ ❑ 0'-0" FIN. FLR�_ _ FRONT ELEVATION 'A' OFF- RIDGE VENT 5HINGLE- ROOF V-4" AFF. TOP OF TIE ;M. a REAR ELEVATION 12 6 1/411 c 11 —011 8'-0" A.F.F. IE TOP OF TBMj!�=- ARCHITECTURAL FINISH 0'-0" FIN. FL v fRIGNT SIDE ELEVATION va^ = 11-011 OFF -RIDGE vENT 5HINGLE ROOF V-4" AFF. TOP OF TIE pM. L- c d+ d' 00 W c� 0 U a W C\2 OU d+ t- Z� w cf) 2 C\l O 4-J Q Q ® W m N � O 0 � W Q i +, i!) 0 _ U 0 U1 +�-) 0 F- U r7 0 X OIL W W�:) �A a w wa ROBERT M. MONTA, P.E 3W U }� w� U� I� 3r I Irw Ov IL Wr'4 Ww as � m O � as W Ir E- O�W F- �HO J� QA Z_W � O 00 cla W_W 00 � W Z� Da Oa Ua Oo o� Wcn pq _ E-� F- Q O a v ) r-I a r � W�lY FV-p O 4 �m WE O mg =Z Ucj �cn }-w aA O U� W 1 lY (> W;ZD ON W X V] N O O C4 O H = 1O } a 0 U vi ^ 00 IM a� c� o a W W cQ w � O E Q ® WQ O va Ld a � Ra W U O co z O co F- U O � 0 I a w a � Wu FY ul � A a� w wa ROBERT M. MONTA, P.E 3w 0 0 WV F- OO QA Zw 2- MO 00 cq ww Fo r , 00 III w z� � o 0� U 00 O1�4 w _ E-F F- �S J a c9 a r-I zcn U F- o ry� W CQ �U) W F- 0 O of E-E F- A S� UO LLV] ?- w aA Ocn U" (I)PQ W aU WN �cn En ZN U W F- Q U O N W Q 14, 2 (9 0 } a O U r� �co Dc �co co 05 00 o � wcid 0V O U a G� W cq a z w v� \2 i � 4-J '� w Q a WQ � ui 0 A p o w PP4 � a zCld z a _ � U � o � Z z O H U D 0 O x IL w o� W� � A a�w w� ROBERT M. MONTA, P.E 3� >- w� S�F- S U� 20 34 i �w OU W!� wr.: N Oa I a: CO O4 n rx w irH O�W F- Nz 0 J aA Z_w O-4 Wo Oo N WW SO V 1 ~U F- q PO oe Ua 00 o� w 0 ~w cn � r , LLI� H fn o S� U� W� 2 F- O 0 o�f E F- A S� O� }w aA OW 0" N W wU w� NO w �cn ,cn Um Z W f- a U O N N a 0 Z Q F- z O a w m N O O N F- S Q' } a O U �f u - 1/2" GYP, BD. ON 2x4'$ PRE-ENGINEERED WD TRUSS, 24" O.C. I/2" G.W.B. OVER VAPOR a 16" O.C. BARRIER W1 R-3 INSUL. TEXT. FINISH ON �/16" BETWEEN 3/4" P.T. VERTICAL OR 15/32" 0.5.8. 12 R-30 INSULATION FURRING 24" O.C. F2x BRG. EXT. WALL HURRICANE ANCHOR AT EACH TRUSS 8 CMU BLOCK (TYP) 6 3-1/2 CON 3'i2" CONC, SLAB(2500P.5,I.) = REFER TO ROOF PLAN " G. SLAB(2500P.S.1. �i2" J-BOLTS 6" FROM hit.. W/6x6 IO/I0 W.W.M. OR EA. END OF WALLW/6x6 10/I0 W.W.M. OR (1) "5 FROM FTC. t0 FIBER REINF. CONC.4 SPACE a 32" O.C.,. FIBER REINF. CONC. TIE BEAM SPLICE TO ON 6 MIL. VAPOR (6 MIN. EMBED) _) I�I=i I-I�"I�) i== (�I I=III= _ SHINGLES ON ON 6 MIL. VAPOR BE MIN, 30" GROUT I — ;•:.,r. I (APPLIED ACCORDING TO MANUF. SPEC) CELL SOLID BARRIE Pt BOt. PLT. - --- ! I= I I== I I (= -i' • - I -� BARRIER I5* ROOF FELT ON ROOF I I I I SHEATHING ON ROOF TRUSSES. _ ,� 'a • 1'' - lXi -� ,,+• � -I f I- I. �I I � 1 - - - �-•' �I I I J( J' � ( / \ \ ;, GRADE X III = i 11= I I 1=1 I !=1 IAI =+ _ GRADE X A/c cHAs� i— . • : w I 1=1 .,�:. ELEVATION VARIES _ _! I (_ III: TOP OF MASONRY ;1TfITII I f v1Tl _ - - 1TI=T� T 1Tf !T _ 4" PVC 5LEEVE III A/C CHASE CLEAN 1 I lI I ICI I I� _ _- I I ICI I ICI I I� I �Z = CLEAN 1 I I - I I ICI I Ii, ` - --III-I I Iz_ WI ICI I = THRU STEM WALL -=---� -I i - —I a •'" �. I I_ „ COMPACTED FILL I I—) I I--311 - I I=I I !`) I I=III' I — -- ? =III—) I ,I I 4 PVC SLEEVE 4' _ i I/2 DRYWALL _ ALUM. DRIP EDGE COMPACTED FILL I; -I I I__i I :,'"'' - ! I I I ! �: -III :III _ I_ a 95% STANDARD i.-i y . ;:Awl r+ tHRU STEM WALL - 2x6 R.S.C. FASCIA a 95go STANDARD I �=-"! � • •�� •' • ' I:- - — I•= lx2 PT NAILER DENSITY ANDI- ", • ".. 1 �,_-) DENSITY ANDI- . ''.y,: I I_u,61 TERMITE 7REATED� '_-=I `4;'' ,:''''., �I P (- TERMITE TREATED ';..' !, , VENTED ALUM. SOFFIT III'-4II TYP. SINGLE TIE -BEAM S"xl6" CONC, FTC. S"x16" CONC. FTC. - - W/ (1) "S CONT. GROUT WHERE 2ND STORY OCCURS W/ (2)'5 CONT. WHERE 2ND STORY OCCURS W/ (2) "S'S GONT. WHERE 2ND STORY OCCURS WHERE 2ND STORY OCCURS - - SOLID FTG SHALL BE 10" x 20" ON CHAIRS. FTG SHALL BE 10" x 20" ON CHAIRS. FTG SHALL BE 10" x 20" FTG SHALL BE 10" x 20" W/(3)WO BAR W/(3)05 BAR W/(3/'5 BAR W/(31'S BAR PRECAST LINTEL I/2" DRYWALL PER PLAN 1 STEM WALL W1 II_ I_ 2 STEM WALL W1 „_ 3 STEM WALL A/C CHASE � STEM WALL A/C CHASE C„tU BLOCK 3/� -1 ,z� WOOD FRAME 3/� -1 ,a C„IU BLOCK 3/4"=1'-o" WOOD FRAME 3/4"=1'-0" "1 ALUM. FRAMED WINDOW } W/ SCREEN FILLED CELL MARBLE $TOO W/ 1" 5 TIED WHILE EVERY ATTEMPT HAS BEEN MADE TO PREVENT HUMAN ERROR,PRECAST GONC SILL <r CONT. ROD CONTRACTORS, SUB -CONTRACTORS AND BUILDERS ARE URGED TO REVIEW I, Ix2 PT FUR STRIP IN FOOTER I/2 GYP. BD. EA. SIDE „ _ ALL INFORMATION CONTAINED HEREIN PRIOR t0 COMMENCEMENT OF AT 16 O.C. SxSxl6 CONC BLOCK CONSTRUCTION. BEAUMONT 4 ASSOCIATES, INC. AND MONTH CONSULTING AND OF 2x'S a 16" O.C. SLAB SLOPES AT DESIGN, INC.(MCD) ARE NOT RESPONSIBLE FOR ANY MISINTERPRETATIONS, NON -LOAD Mks" PER FT. AWAY ERROR', OMISSIONS OR CUSTOM CHANGES MISSED AND NOT REPORTED TO BRG. WALL GARAGE INSULATION ON VERT REINF. BEYOND FROM HOUSE BEAUMONT 4 ASSOCIATES, INC. OR MCC) PRIOR TO CONSTRUCTION. NO INTERIOR OF BLOCK WALL - „ EXCEPTIONS. EXTERIOR FINISH (SEE ELEVATIONS) -� 4" CONC. SLAB J-BOLT a 32" O.C. (MIN INTERIOR GARAGE INTERIOR 6 EMBED) 6 2 1/4 _ FROM EA. END QC 5P-4 EA. STUD Ix4 PT BASE NAILE _q PT BOt. PLT. tOP4BOT, WOOD BAS FIN. GRADE ' • � � °' a'• .� . •.. "�' __" � A• I MAIN FLOOR �i,.� :.:r;::'" ELEV 0'-0" e _ �' ' —III==f =1 I Iii I I� �� 111=1 I ► �rr�_rrlrr�rrrrrr_ C.M.U. FOUNDATION CONT. • (3) *5'5 CONT.I lu -_ _ ----� I ==1 — i-- :LI �=1 — — 8 w_� i W/ 3" MIN. CLEAR I i�=l I I --I I, _ y� —I �-- _ Im" �! 1m" !_ I I_ _- W� �I I I- �I i 1—I �_i-1ff I �--I;I•-'ii--••� � �I�=1� q I ;III=I�I=III=— NO REINFORCEMENT REQUIRED III24"-=� I I—) I I —III ; III=I I I e=I — I I -- - 2-15 CONT. 24" X 24" X12" d CONC _ _ V • • - _ ROOTER W/3�— ROD EACH WAY `� I -- --- � CLEAN COMPACTED CLEAN, COMP., TERMITE 1 4 " POISON TREATED TREATED FILL FILL COLUMN FOOTER DETAIL 6 NOT USED � OFFSET" FOOTING 8 OFFSET FOOTING �� WALL SECTION W1 3/4" = 1'-0 NON BEARING 3/4II_11-�" BEARING 3/4"=1'-0" C" IU / STEM WALL 3/� =1 -r� COMP. SHINGLES OVER 15" FELT ON 'i/16" 0.5.5. MIN. PRE-ENGINEi=RED TRUSS 6 24" O.C. W/ HURRICANE ANCHOR I/2" GYP. BD. EA. SIDE 1/2" GYP. BD. EA. SIDE ON EA. TRUSS OF 2x'S a 16" O.C. OF 2x4'5 a 16" O.C. - 5P-46EA. STUD ''12 "X-i" EXPANSION SP-4aEA. STUD tOP450T. U.N.O. TOP4BOT, U.N.O. ANGHOR5a32" O.G. 112 "X�" EXPANSION PT BOT. PLT, PT. BOT. PLT. ANCHOR5a32" O.C. .4 ♦ •.,d.r •rd r a �; A•• •r. d� .. P .•} •A. SEE ELEVAdk .,1 d Y, A '�• �.. ,. •e�; �. a d' •4 r' +'+.=T I--' _ • -) � �=I 11= I i 1=1 � " ` .r.•. ,,.1=I I I_`""I I I._ � �) � I��I I I.�"I ,; , . ,•�,� •.: ''j' —) I �-- :�%�`• R-3ID BAT7 INSULATION CONT I--;-- � � ` :"�'�'� �'• (2) «5'S C -I I _ ! 11— 1 I ! �I ! I= ''=_ ICI I I III =1 11==1 ,1 I I :...:; :.,;; 1/2" GYP. BOARD W/ 3" MIN. CLEAR �" 'I I" "_-' �' "' FILLED LINTEL BLOCK W/ 145 �� (3) *5'S CONT. 8 811 W/ 3" MIN, CLEAR 10" l0" CONT. HORIZ. W/ 30" SPLICE MIN. REFER TO CA5TCRETE 5PEC5 FOR LINTEL REQUIREMENTS g INTERIOR BEARING 3/a."=1'-,a" l,a INTERIOR TWO II_ ,_ Il 19 TYf=. SECTION - OPENING STORY BEARING 3/� -1 ,a 3/4"=1'-o" 3/4" RECESS 05 ROD IN FILLED CELL PER MFG. a SLIDING �A5 PER FLOOR PLAN SPEC' GLASS DR. g" TIED TO CONT. ROD IN WALL BEYOND FOOTER 4 LINTEL ROD ABOVE 31/2" CONIC. SLAB W/ FIBERMEBH SLOPE 3'i2" GONG. SLAB W/ FIBERME5H (OR W/6x6 10/10) FINISH GRADE - _ (OR W/6x6 10/10) OVER 6M VI50. - - OVER 6M VISQ, 3-1/2" CONC. SLABNA if II IIIIIIIr — — .a . '.a 5LIDING GLA55 DR, �"' GRADE •.. ,s:. ;. .*; _ __ _ ' .. '�-' �y�'•.r �I I=i�i 1-i { I-Iii=i i 1- - - �� I ----� =I 11-1 I I- I I 1=1 I I —:I 11=111=11 41/2" CASING I JA 4 I-- III l_I i I = III =III —I I I -`III- ALUMINUM THRE5HOL SLOPE axe THICKENED " x 5" THICKENED EDGE W/ 1 -*5 SLAB W/ (I) +'2 CONT. 3-1/2" CONC. SLAB(2500P.S.1. 3/4" RECESS CONT. W/6x6 10/10 W.W.M. OR DRIVEWAY SLAB FIBER REINF. LONG. - - SLOPE 1/4"a" X Ih" GONG. ON 6 MIL. VAPOR = - PER F Ot EXP JOINT FOOTER W/ 2 05 CLEAN, COMP., BARRIER = - 3R MIN. CONT. CcE TERMITE TREATED PER MFG - = FILL SPECS. WHERE 2ND STORY OCCURS EXTERIOR DOOR FTG SHALL BE 10" x 20" 13 THICKENED EDGE ,I _ I _ II 1� THICKENED EDGE 3/4 =1' -0" 15 NT5 C�,4I<AGE CURB W/(3)'5 BAR Q GARAGE DOOR 3/4 -1 ,a POURED SILLS 18 DETAIL ;` CC) I I co � 00 441 -t w L m • r-4 '4 A o ®� a o w Q L) D z W UDN 2 Q z - Q o A +-' � C/) w Whr a I U m O z o c� I= U 13 O a w w x wL �cr. W e: as w ip wa ROBERT M. MONTA, FIX 3W U itH o w No a� zW �o o0 =o U� 00 W W O o O� Ua O� o� W �a I. O a V)4 W� 0 00 I O 4 O 0 M E+ F- P 2� .o y Q � 0 o co C\2 I I o b V o P+ 'd v w U d D1 DBL TOP PLT. '-HURRICANE CLIPS OR TRUSS ANCHORS - SEE ANCHOR SCHEDULE (-'T' . BOARD (4) ,Sdx2" MIN. TOE NAILS EDGE BLOCKING-r----\ EA. JOIST TO TOP PLT. NAIL RIM BOARD -si) &I' O.G. STRAP TOP PLATE, HEADE � 2x4 STUDS a 16" O.G. SIMPSON 5P1 OR SP4 CRIPPLES TOGETHER W/ CMU WALL 2 (OR p�TTER) SYP OR 5PF TOP PLATES TO STUD LTSA 18 MIN. U.N.O. PER PLAN CONNECTION A7 16" O.G. 2x DBL. GYP. BOARD —TRUSS TOP PLT. 2x4 STUDS 9 IG " O.C. #2 (OR BETTER) SYP ABOvE PRE -ENG. 2x STUDS MID SPAN BLOCKING W FLOOR SYSTEM 1G>" O.G. (X BETWEEN EA. STUD DBL. TOP PLATE 5TC=40 MID SPAN EA. STUD BLOCKING ANCHOR BOLTS i (4) EQ. SPACED 2x PT BOT. PER PLAN 1/z GYP. )BOARD 3/1G "x 3 1/4" SIMPSON PLATE. IMPSON SPI OR 5P4 PT BOTTO TITENS w/ WASHERS, SPF STUD 1/ " J B'@ OLTS 32" HURRICANE CLIPS '@ Iro" AND BOTTOM O.G. PLATE 6 MAX FROM TOP -SHEAR WALLS TO BE viz" GYPSUMO.C. MAX ro" EMBED. 2x4 P.T. PLATE WALL BOARD "STAGGERED, BLOCK 6 MAX FROM E.A. END z" GYP- BD. ALL EDGES, STUDS'a 1(o O.G. No.ro REFER TO FOUNDATION 1'14" SCREWS TYPE W OR S, FASTEN PLAN FOR FOOTING SIZE PLYWOOD OR O.S.B. 4" O.G. PANEL EDGES AND FIELD. AND LOCATION STRAP TOP PLACE, HEADER a FOR UPLIFT INT. LOAD IMF -SON SPl OR SP4 CRIPPLES TOGETHER W/ 3 C� �� I I �'�" I /��� _, � -�ii I) I WALL /� 15 E XT. FRAME WALL CONN. P PLATES TO STUD LT5A 12 MIN. U.N.O. 2x4 P.T. PLATE -- LATE +- L L SEARING WALL �-�/2�� _ ��-emu J� WALL I T ONNECTION AT 16" O.C. �O BLOCK UJ�LL II����_,'-��� j 2x4 STUD5 a I6" O.G. J" BOLT 32" O.C. jl #2 (OR BETTER) SYP OR SPF ID SPAN BLOCKING_ f� ETWEEN LA. STUD (1)"5 IN TIE BEAM (1 *5 BAR IN PRECAST LINTEL 41� CHOP, P R PLAIN GYP. BOARD NOTES: ALL LAPS 4a BAR DIAMETER MIN. fK (2)#5's VERTICAL -10 WINDOW AND DOOR ASSEMBLIES To CONFORM �ILq IN GROUT FILLED IMP60N SPI OR 3P4 TO FBC 2001 CHAPTER l­SECTION 170�1.4 RUNNING BAR NOM. 8" KNOCK -OUT �m (1)# 5 CONT. IN TIE CELL HURRICANE CLIPS e 16" O.C. ALL CONNECTIONS BY OTHERS SHALL BE BLOCK cv~ BEAM COARSE (I)#5 VERTICAL IN x4 P.T. PLATE CAPABLE OF RESISTING THE DESIGNATED GROUT FILLED CELL WIND FORCES SHOWN ON SHT. 2 (FLOOR PLAN). DOWEL LAPPED PROVIDE HANGERS TO HOLD WITH WALL REINF. GROUT TIE BEAM REFER TO FOUNDATION COARSE SOLIDS o. BAR IN PLACE DURING P®UR, PLAN FOR FOOTING SIZE 2X PT BUCKS/NAILERS SHALL EXTEND BEYOND REFER TO MAN. SPECS. FOR a AND LOCATION INTERIOR FACE OF WINDOW, FASTEN . SPACING REQUIREMENTS BUCK TO MASONRY W/1/4"X3" 7APCONS - NOM. a" CMU ro" FROM EDGES AND 16" O.C. MAX. BUCKS LESS THAN 2X TO BE FASTENED PROVIDE SCREEN WHEN BLOCK BELOW IS NOT W/CUT NAILS OR EQUIVALENT, STRUCTURAL REQUIRED TO BE FILLED I' I I WALL CONNECTION OF WINDOW TO STRUCTURE LZ*5 CORNER BAR lk I INT. LOAD I RG. WALL <NEE IW'AI,I.,I. L ION TOP BY OTHERS IN Tr 15 CASE, GROUTED CELL NOTE: ALL 1-100<5 I SPLICES TO BE 2 STORM, WALL ASV ' OF CMU WALL 1- 1/2 = V-0II CONSTRUCTED AND SDED PER NOTES UJINDOUJ/DOOi�. T�F. CORNER VERT. NOTE: TIE BEAM COURSE MAY BE USED ILO OF KNOCK-oU7 5 8 BLOCK 7O ELIMINATE USE OF HIANGERS, 2" COVER MUST REMAIN 5UCK NOTES NTs WALL REINFORCING NTs 12 TIE �3EAM DTL• 11/2II=I'-��� 1� R ,� ' D �' IL NTS i 2x4 5TUD5 16" O,C, 2x4 STUDS 16" O.G. r #2 (OR BETTER) 5YP OR SPF #2 (OR BETTER) SYP OR SPF LtS-I� GYP. BOARD ',2" GYP. BOARD PRE - ENG. PRE =ENG. FLOOR SYSTEM FLOOR SYSTEM MSTC-40 I EA. STU9 —TIE-BEAM— PRE CAS HEADER PT 2x4 NAILER 2x4 BLKS. EXT. SHEATHING P€R PLAN PRECAST SILL w w' X (,�, X 12 P.T. OF OPENING CENTER BUCK MIN. L57A-12 RAFTER TO RAFTER OVER RIDGE • )— I 1" EDGE 1 1/2" EDGE-) 2 1/2" EDGE-) 2X8 RIDGE B AR DIA. ANCHOR 2 X 4 P.T. TOP BUCK 10dX3" 0 COMMON Q X L w ui ®- 2 X ro P.T. BUCK EACHI I/�" FASTEN SYP OR SPF SIDE OF OPENING d IOX31 2X�o (MIN. WIDTH) PLATE GOMMO THRU 1/1ro" O.S.B. SHEATHIN 3/0" DIA. J-BOLT W/ 5-I/2" EMBEDMENT 10dX3" X X, Z TO PRE-ENGINEERED TRUSS BELOW WITH 1/4"x4-1/2" SIMPSON • AT EACH DOOR BRACKET, EACH SIDE OF COMMON Z 2XG 'S 2 24" O.G. MAX. DOOR. PROVIDE 1=1/2" X 3/16 " THIICK OFF. SIDE _ SD5 SCREWS 2Xro PLATE TO WASHER W/ EACH ANCHOR. U TOP CHORD OF EA. TRUSS BELOW FASTEN CONVENTIONAL 2X VALLE X 100IX3" to IX RAFTER FRAMING (OR PRE-ENGINEERED DUCK sP>=cIFIED DY COMMON VALLEY TRUSSES) TO 2X PLATE WITH %� SIDE— WINDOW/DOOR OPP. DE) 5IMP50N H2.5 CONNECTORS (5-5d NAILS) MANUFACTURED AT EACH RAFTER TO PLATE CONNECTION NOTE: ARCH�.PSS WINDOWS SIMILAR START BOLTS AFTER (2)2X4's (2)2X(o's (2)2XVs GARAGE CURB 1,211 CaYP. BD. (: ) � ARCH WINDOWg �31�C� l��fi�l� NT5 13 2X �31�1L�'-l�� StI�I� I 11_ � �� 1-r GYP. FRAMING DETAIL NTs COLUMN DETAIL5 1/2 -� -r� TYf=. VALLEY CONNECTION STRAP TOP PLATE, HEADER a STRAP TOP PLATE, HEADER IMPSON SPI OR 5P4 CRIPPLES TOGETHER W/ SIMPSON SPI OR SP4 CRIPPLES TOGETHER W/ OP PLATES TO STUD LTSA 12 MIN. U.N.O. TOP PLATES 1-0 STUD LT5A 12 MIN. U.N.O. 4" BACKSPLASH ONNECTION AT 10" O.G. CONNECTION AT 16" O.C. OUNTERTOP 5 1/2 2x4 STUDS Q 16" O.G. r 2x 5TUD6a 16" O.C. 2 (OR BETTER) SYP OR SPF #2(OR BETTER) SYP OR SPF EXTE p TO ID SPAN 5I-OCKING MID SPAN BLOCKIN�s -f/Iro O.S.B. J 1# 5 BAR CONT. �� PAST RASE BETWEEN EA. STUD 2x8'se12" O.C. 4" MTL, STUDS lro° ETWEEN EA. STUD O.G. BUILDING WRAP ■ T11=-?BI=AM MSTAM=24 EA. SIDE 1/2" M.R. GYP. BD. OF EA. STUD TO CEMENTITUOUS FINISH ANCHOR 5OLT5 ANCHOR BOLTS TIE BEAM BELOW CERAMIC TILE .� PER PLAN ''/2" GYP. BOARD PER PLAN �2" GYP. BOARD RECESSED CEMENTITUOUS WATERPROOF / IMPSON SPI OR "SP4 PRECAST FINISH STOP IMPSON SPI OR SP4 HEADER HOLD 0.5.5, B BACK 3/lro" SEALANT HURRICANE CLIPS a 16" O.G. HURRICANE CLIPS a 16" O.C. 2x4 P,T, PLATE FLASHING N 2x4 P.T. PLATE � 2Xb P7 BOT. PLT. BASE CABINET 1O FEhFfh REFER TO FOUNDATION T z J-BOLT W/SIMPSON TUB REFER TO FOUNDATION P NAIL€ 8�' CMU AS LBPS'iz WASHER�32" O.C. PLAN FOR FOOTING SIZE � PLAN FOR FOOTING SIZE AND LOCATION AND LOCATION MAX.(MIN. -I" EMBED.) " BOARD POURED CELL W/1 #5 BAR 1/2 GYP. CEMEN7ITUOU5 FINISH{ CONT. FROM BEAM TO ` FOOTING. BUCK SPECIFIED BY WINDOW/DOOR MANUFACTURER 19 INS'. LOAD 5fRG. WALL, 2 INS'. LOAD 5IRG. WALL, i� COUNTEfR/TU5 2 5TORY, WALL A5V 2 5TORY [:)OCR 5UCK DTL. NTs STEP DOWN TIE � EAM I� WALL 5PL ICE DETAIL WALL DETAIL I L-co ', "t c\j r\l I I �CO F•-■I � � V1 00 Lli 2 • V � '�r4 a Q; W c�2 fy Q �CQ z� w sn C\t i C' z 2 -•-j Q a i�l ®w u� a A W to Q..' a, C/] w U � O z +� O � H U D 0 O a W a W W Q� aA a� Wf!I wa ROBERT M. MONTA, P.E 3W U w� Uco ='m 3� aU O� a ww w Ow a °" it to D as w 0 O w U V,z 0 QA Zw Fo oo cli WW U V ) 00 H� 0 i� 0 U Oo o� O ~w 0 a mm a Wm � w V)p O Q too c� Wul O J� E�-E I... A 1� to W Q U 0 W W Q 0 z Q z O i D w m N 0 0 N m COMP. SHINGLES OVER lra# FELT ON O.S.B. MIN. PRE-ENGINEERED TRUSS 'a 24" - O.C. W/ HURRICANE ANCHOR ON EA. TRUSS eeeme um lhihl C � C SEE ELEV — R=30 BATT INSULATION — 1/2" GYP. BOARD FILLED LINTEL BLOCK W/ 205 CONT. HORIZ. W/ 30'' SPLICE MIN. SLAB SLOPES AT /a" PER FT. AWAY FROM HOUSE 4" CONC. SLAB FIN. GRADE z - �I� 24" X 24" X12" d CONC _ _ 24 FOOTER W/3 #5 ROD EACH WAY - CLEAN, COMP., TERMITE TREATED FILL SECTION THROUC;H LANAI WHILE EVERY ATTEMPT HAS BEEN MADE TO PREVENT HUMAN ERROR, CONTRACTORS, 5U5-CONTRACTOR5 AND BUILDERS ARE URGED TO REVIEW ALL INFORMATION CONTAINED HEREIN PRIOR TO COMMENCEMENT OF CONSTRUCTION. BEAUMONT 4 ASSOCIATES, INC. IS NOT RESPONSIBLE FOR ANY MISINTERPRETATIONS, ERRORS, OMISSIONS OR CUSTOM CHANGES MISSED AND NOT REPORTED TO [BEAUMONT 4 ASSOCIATES, INC. PRIOR TO CONSTRUCTION. NO EXCEPTIONS. 3/4" = V 2X4 BLOCKINCa'@EA. OUTLOOKER (ROOF SHEATHING SPAN TO BE 2 AO° MAX.) END NAIL W/(2)16d 2X4 OUTLOOKER '024'' O.C. MAX. -1/16" O.S.B., MAIL PER NAILING SCI 2)16d NAILS PLT. TO iTUD TOP450TTOM(TYFd END NAIL PLTS, TO STUD) 31MPSON H-10(TYP.) ?X FACIA, END NAIL J/(2)IG d NAILS@EA. DUTLOOKER 40LD WALL DOWN 31/2" -OR OUTLOOKERS /IG " O.S.B., NAIL DER NAILING SCHEDULE 2X6's'w16" O.G.W/FULL DEPTH BLOCKING 5'-0" O.C. MAX. NOTE: PROVIDE ADDITIONAL BLOCKING AS REQ'D. PER HIB-V 4 TRUSS MAN. DRAWINGS CEILING GYP. BOARD IS NOT A DIAPHRAGM GA5LE END SIVAUL.TED CEILING (5ALLOON FRAMED WALL) WALL PL SHEATHING F PLAN BEAUTY SHIN W/ MASTIC Ol NOTES: 1. MOISTURE BARRIER: APPLY HORIZONTALLY W/ MIN. 2" HORIZONTAL LAP (UPPER LEVER OVER LOWER LEVEL) 4 6" LAP AT VERTICAL JOINTS FASTEN PER MAN. SPECS. 2. UNDERLAYMENT APPLICATION - FOR SLOPES 4:12 AND ABOVE - MIN. I LAYER. START AT SAVE ( PARALLEL) PROVIDE MIN. 2" LAP W/ SUCCESSIVE LAYERS. FASTEN PER MAN. SPECS. NOTE: ALL FASTENERS FOR UNDERLAYMENT TO BE MIN. 12 GA.xI'/4" CORROSION RESISTANT ANNULAR RING SHANK OR COIL ROOFING NAILS THROUGH 32 GA.xl%'' DIAMETER TIN GAP. 3. SHINGLES = FASTENING - (4) NAILS FOR EVERY FULL SHINGLE, P FROM EA. EDGE -a 12'' O.G., NAIL ROW TO BE LOCATED APPROX, E55/a" FROM LOWER PORTION. ALL FASTENERS FOR SHINGLES TO BE MIN. 12 GA.xI" CORROSION RESISTANT ROOFING NAILS W/ Na" HEAD USE ROOFING CEMENT FOR MAN. SPECS. 4. DRIP EDGE - MIN. 26 GA_ GALV. STEEL AND OVERLAP A MIN. OF 2" DRIP EDGE TO EXTEND 1/4" BELOW SHEATHING AT EAVES AND EXTEND BACK TO THE ROOF MIN. 2 DRIP EDGE TO BE FASTENED W/ MIN. 12 GA. CORROSION RESISTANT ANNULAR RING SHANK NAILS a 12" O.C. MAX. a. FLASHING= MIN, 26 GA GALV. STEEL FASTENED PER MAN. SPECS. &.VALLEY LINING(CLOSED VALLEY) - PROVIDE (1)LAYER OF 30" WIDE ASTM D 1910 COMPLIANT UNDERLAYMENT 5 SHINGLE / FLASHING DETAIL BARRIER FELT OOF COVERING :EL ELF -SEAL -OCKING AND CONFORM ASTM D 3462 UNDERLAYMENT TO CONFORM WITH ASTM D 22ro, TYPE I, OR ASTM D 4069 TYPE I. PROVIDE MIN. 26 GA. GALV. STEEL DRIP EDGE 2X4 BLOCKING�EA. OUTLOOKER (ROOF SHEATHING SPAN TO BE 2'-0" MAX.) END NAIL W/(2)1iod 2X4 OUTLOOKERS NAILS EA. END 024" O.G. MAX. 1/16" O.S.B., NAIL 2'-0" MAX. PER NAILING SCHEDULE END NAILA. OUTLOOKER , W/(2)16d NAILS TO TRUSS DBL. 2X8 TOP PLT. — PRE-ENG. ROOF TRUSS 2X8's �l6" O.C. (TYPJ 1'-9" MAX. /2" GYP. BOARD CEILING NAILER AS REQ'D. 1/2" GYP. BOARD ON PT. FURRING (2)16d NAILS PLT. TO STUD TOP45OTTOM(TYP.) (END NAIL PLTS. TO STUD) SIMPSON H-10(TYPJ 2X FACIA, END NAIL -}—'-' W/(2)16d NAILSo)EA. OUTLOOKER M HOLD WALL DOWN 3/2" FOR OUTLOOKERS l/16" O.S.B., NAIL PER NAILING SCHEDULE /2'' J-BOLT W/SIMPSON L5P5'/2 WA5HER'532" O.G. MAX. (MIN. (o" EMBED.) CMU WALL. BELOW LST4-24 W/(6)3/16"XI-1/4" SIMPSON TITENS TO CMU (TYP. EA. STUDXEA. SIDE) REFER TO FLASHING DETAIL FOR FLASHING REQUIREMENTS NOTE: PROVIDE ADDITIONAL BLOCKING AS REQ'D. PER NIB-91 4 TRUSS MAN. DRAWINGS CEILING GYP. BOARD IS NOT A DIAPHRAGM 1 GA5LE END aVAULTE1) CE IL ING(C" IU WALL) 2x4 BLOCKS, l2) 16d NAILS � J=A. END. BLOCK ADJACENT BAYS €A. DIAGONAL AS SHOWN. FASTEN ROOF SHEATHING TO BLOCKS w/8d NAILS 1'-4" M ?<. CONT. 2X4 ` 2X4'5 a 24" O.G. l5) 16d NAILS BRACE TO REFER TO PLANS FOR BLOCKING EXACT SIZE OF O.N. PRE-ENGINEERED GABLE END TRUSS —GABLE ENE) SHEATHING FASTEN PER PLAN. PROVIDE 2x4 BRACE TO SPLICE AS REQ'D EA. ADJ. DIAGONAL FASTEN TO DIAGONAL 02) l( d NAILS. 5IMP60N A239EA. 1x4" I IOL BRACE TO PLT, 1/2" J-BOLTS W/WASHERS(MIN. (o" EMBED) MIN. (a" FROM EA. END AND 32" O.C. MAX. GABLE BRACING a 4a" O.C. L5TA-12624" O.G. BOT. OF PLT. TO MAX. 45' FROM HORIZONTAL GABLE TRUSS, ATTACH STRAP TO PLT. (+/ 10°) BRACING NOT REQ.'D BEFORE PLT. IS INSTALLED WITHIN 6'-0" OF EAVES --TIE BEAM COURSE PT 2Xa PLT., CANT, FJ/VM\—GMU W/(1l5 CONT. NAILING SURFACE WALL PROVIDE 16d NAILS GABLEEND_ BELOW TRUSS To PLT.1@12" O.G. MAX, 2 C1„I'U W74L L G415L E ENID W/FL AT CLG. I`�j�� IS 2x4 BLOCKS, (2) 16d NAILS a EA. END. BLOCK ADJACENT BAYS a EA. DIAGONAL AS SHOWN. FASTEN ROOF SHEATHING TO BLOCKS w/3d NAILS -I 3 CxABLE ENDaFLAT GEILINCx (BALLOON FRAMED WALL) 3/4" =1' -0" 2X4 OUTLOOKERS a 24" O.G. H-10 a FA. TRUSS PROVIDE 2x4 BLOCKING ABV. GABLE TRUSS a EA OUTLOOKER. GABLE TRUSS HELD DOWN 3'%" FOR OUTLOOKERS. CxABLE END SHEATHING FASTEN PER PLAN. SIMPSON HGA-10 a 4a" O.G. DBL. 2x4 TOP PLT SIMPSON H-10 DIAGONAL TO TOP PLT. FASTEN SIDE WALL SHEATHING PER PLAN. 3/4" =1' -0" i L_co C\2 Chi L_ L I I 00 F- •V _ �� c� U a o W Q a� N H Z W 6 �m cn m a� ';-4 w H Q a® W Q) cn o • 6 1 W Un U � O �5 0 1- U � C 0 ct a w u i W a92 04 ELM W� �A W wa ROBERT M. MONTA, P.E 3� >-cn w., U ap Io 3� I C)pq U O!Q W4; Oa Omm a-c4 W 0 O w Nz J QA _ZW O1-4 jxo 00 cQ wW �O U W Oc.D ^� W z 0 o w pq O� I U O� Da�v W _E" O T .. Lo ~a C1 PgWa � r-I F- V)p 0 �o o U� W�. 2 H O O off E" TWA =Z 00 Lr.(n >- W a.A O" U mw W� m� W� Or W �cn Um Z �•i F- Z 0 i D a W m O ;, m -6 O c� W O 0 1 P T1 VI w U d H 2 (9 rr } 0- 0 U [OR L- co C\t �t V � � t/l 0o W Ct �� m•7 a>1 0 ®a� m w� Q o� Z � cat w � a � Q a ®W oo� W Z A S U O� N z � � r� O F- mp W (Yi w� 2�H 2 Uco SO 3� i 0�w Ov w!Q W� N O d� jrm 0 0 w� H J QA ZW _ U-4 � o ON wW V ) 00 N w O pq O�U Oo Lie in W S 0 L1 J U WG4 /-1 l / 1 T q f/10 C9 W� S� H O O C�H H�S OpW � U W�D (nW W E� mu) U cn Z Ey W a z Q F- z 0 Q w m N 0 0 N O F- S U } a 0 U WHILE EVERY ATTEMPT HAS BEEN MADE TO PREVENT HUMAN ERROR, CONTRACTORS, SUB -CONTRACTORS AND BUILDERS ARE UR3ED TO REVIEW ALL INFORMATION CONTAINED HEREIN PRIOR TO COMMENCEMENT OF CONSTRUCTION. BEAUMONT < ASSOCIATES, INC. IS NOT RESPONSIBLE FOR ANY MISINTERPRETATIONS, ERRORS, OMISSIONS OR CUSTOM CHANGES M155ED AND NOT REPORTED TO BEAUMONT f A55OCIATE5, INC. PRIOR TO CONSTRUCTION. NO EXCEPTIONS.