Loading...
HomeMy WebLinkAbout329 Lusitano Way 03-2651 New SFH- --_i PERMIT ADDRESS �C CONTRACTOR ADDRESS PHONE NUMBER PROPERTY OWNER ADDRESS PHONE NUMBER D R Horton 6250 Hazeltine Nat'l Dr #102 Orlando, FL 32822 (407)857-9101 __.. CBC 055300 ELECTRICAL CONTRACTOR 1�,p C- o p.� � MECHANICAL CONTRACTOR PLUMBING CONTRACTOR MISCELLANEOUS CONTRACTOR PERMIT NUMBER MISCELLANEOUS CONTRACTOR PERMIT NUMBER FEE FEE :D• PERMIT .CS1 L--P,,4DATE PERMIT DESCRIPTION PERMIT VALUATION SQUARE FOOTAGE Mj� ►t, d d r� cn cn I 01 R w DESIGN CRITERIA: • FLORIDA BUILDING CODE (FBC) '*OCCUPANCY- RESIDENTIAL - GROUP R • CONSTRUCTIOPd TYPE — vi 2001 • 1-STORY REST-DENCE: BLDG HGT 10'-8" SPECIFIC PARAMETERS FROM ]FBC 2001 CH.1606 USED FOR DESIGN INCLUDE: ® SSTD-10 • CONCRETE MASONRY RESIDENTIAL CONSTRUCTION * WOOD FRAME CONSTRUCTION MANUAL • WOOD PRODUCTS PROMOTION COUNCIL • AMERICAN SOCIETY OF CIVIL ENGINEERS 1. ALLOWABLE UNIT STRESS AND DESIGN CRITERIA: A. BUILDING CODE REQUIREMENrTS FOR REINFORCED CONCRETE ACI 318 B. FLORIDA BUILDING CODE (FB(C) 2001 2. SOIL A. NET ALLOWABLE SOIL BEARING PRESSURE USED IN DESIGN 2000 PSI FOR CONTINUOUS WALL FOOTINGS. 3. CONCRETE AND REINFORCING A. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH ACI 318 AND WITH SPECIFICATIONS FOR STRUCTURAL CONCRETE BUILDING ACI 301. B. ALL CONCRETE SHALL DEVELOP MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI IN 28 DAYS C. REINFORCING BARS SHALL CONFORM TO ASIM A615 A616 OR 617, GRADE 40 4. DESIGN LOADS A. IN ACCORDANCE WITH THE FLORIDA BUILDING CODE (FBC) 2001 CHAPTER 16 ROOF LIVE LOADS OF 20 PSF, DEAD LOAD 17 PSF WIND LOADS IN ACCORDANCE WITH FBC, SECTION 1606, 2001 EDITION FOR 120 MPH 3 SEC GUST REGIOIN, INTERIOR PARTITIONS PSF PERPENDICULAR TO WALL FACE (DETERMINATION OF WIND FORCES AS PER. FBC, SECTION 1606.1) B. STRUCTUAL LOADS FLOORS @ SLEEPING AREA 30PSF LIVE 1OPSF DEAD FLOORS @ NON —SLEEPING AREA-40PSF LIVE 10PSF DEAD BALCONIES-40PSF LIVE 1OPSF' DEAD DECKS-40PSF LIVE 1OPSF DEAD STAIRS-40PSF LIVE 1OPSF DEAD ROOFS-20PSF LIVE 17PSF DEAD C. BASIC WIND SPEED MPH (M/S))= 120 D. INTERNAL PRESSURE CO—EFFI[CENT=+ .18 E. BUILDING CATEGORY=B, USE ]IMPORTANCE FACTOR 1.0 5. LUMBER A. ALL STRUCTURAL LUMBER SHALL BE #2 SYP. ALL STUDS SHALL BE #2 GRADE OR BETTER SPF. (ALL LUMBER EXPOSED TO WEATHER, OR AGAINST SOIL, CONCRETE OR MASONRY SHALL BE PRESSURE TREATED) 6. TRUSSES A. PRE—ENGINEERED WOOD TRUSSES SHALL BE DESIGNED IN ACCORDANCE WITH FBC 2001 EDITION. TRUSS MANUFACTURER SHALL SUBMIT SIGNED AND SEALED DRAWINGS FOR APPROVAL PRIOR TO FABRICAUION. 7. GARAGE DOOR/ WINDOWS/ DOOR A. ENGINEERED FOR 120 MPH 3 SEC.GUST MIN. WIND LOAD . B. DETAIL TO BE SUPPLIED BY NAANUFACTOR ENG.SUPPLIER C. DETAIL TO BE ATTACHED TO PERMIT PACKAGE BY BUILDER INDEX: PG C1 COVER PAGE PG 1 FOUNDATION /D)OWEL PLAN PG 1A LINTEL SCHEDU ]LE PG 113 WIND LOAD CALICULATION PG 2 FLOOR PLAN PG 3D ELEVATION "D" PG 3E ELEVATION "E" PG 3F ELEVATION "F" PG 4D TRUSS PLAN PG 4E TRUSS PLAN PG 4F TRUSS PLAN PG 5 ELECTRICAL PLAN 7 6, c)2 www. drhorton. com CBC055300 6250 Hazom..ritime Natic>naj E:>rivc=,. C>rlancfc> FL. 328 • (407) 857• 228 D.R. HORTON HOMES 6250 Hazeltine National Drive Orlando, FL 32822 Tel: (407) 857-9101 Fax: (407) 857-9228 • STATE OF FLORIDA PROFESSIONAL ENGINEER: KENNETH ROBERT COYNE PE NO. 53747 A.B. DESIGN GROUP, INC. 1441, CR. #427 NORTH LONGWOOD, FLORIDA 32750 Tel: (407) 774-6078 Fax: (407) 774-4078 ® STATE OF FLORIDA PROFESSIONAL ARCHITECT JIM CANTWELL AR 12079 A.B. DESIGN GROUP, INC. 1441, CR. #427 NORTH LONGWOOD, FLORIDA 32750 Tel: (407) 774-6078 Fax: (407) 774-4078 Ora ni co�1P "' y l c 111101, Lai JUL 0 1 2003 BAKERS CROSSING LOT #137 PHASE #2 DATE: 6/30/03 SCALE: 1/4101.0' SHEET C I ®F' 2 40'-0" 28'-2" 8'-211 3'-8" 21'-9" 9'-0" 3'-3" 0 -0"11 14'-11" *-3 1/2" p 31/2" 3 4) CONC. PE5 -- — — — — SLAB ■ , I LAV. 1 /.---.\ I = rl 0% EXTEND SLAB 1 1/2" I � � I I I -------�,-- ��-------f — `� I— ---------� (OPT. _ REF. I I�wc. ► I II � � l I■ � �' '� I /�,..�\ III � I o 4'-1" 2'-G " 1'- 13'm0" I cD ra � 2xro WALL m LLJ I ( I ICI 0'-0" ELEV. I— — — FIN. CONC. SLAB ,opo �, goo �, r — �-; J r I RANGE( l ( - I 1 3 1/2" CONC. REINFORCED LAV. W/6 "X(o" 1110/10 WWM OR = I FIBERGLASS REINF. ON 6-MIL. r VAPOR BARRIER ON WELL -COMPACTED b I CLEAN TERMITE TREATED FILL OR I I APPROVED SUBSTITUTE, (RECRUIT 11 SYSTEM) I t TUB I ----- — ---------� 20'-11" 19'-1" OPT. I — W. L--J EXTEND r - - -, D1 SLAB 1 1/2" I OPT. ter- I D 3'-� I ■ WH.IN -' SAFETY FAN^ F A/c FOND. -3 1/2" m CONC. SLAP = -- _ (74" \ ` i -� - _ _ -- P.V.C. 14'-4" CHASE 0'-0" ELEV. FIN. CONG. SLAB Is � I ■ 8 D1 1 U w I D1 pl ■ (� } N QNZ ELEV. D4F O O O BRG. FTR U I r Q Ll 2 0'-0" ELEV. Qz FIN. CONC. SLAP w U = D 1 EXTEND ■ � � _I — SLAB 11/2" 8" CURB I I ■ WALL Il 4 1/2" ■ 1 I D1 � I N Dl I 17 _ J 3 1/2" CONC. SLAP lro'-0" 2'-10" 21'-KJ" 4'-011 13'-10" NO Now),) MOP W 000 11111`1 rIff"JOIN")z u J) a 10 All m�� 1112101DW MH MR0,10 Ki'll N.T.S. I - - - - - - - - - - - - - ,_-- ------------------------ ■ I I — — — — I I 0 NJ \\ I 3'-011 LUC. I I I 11'-0" I �I -,��r y i-------------------------------� - 4'-" -2" ► ELEV. �I "F" DOWEL LAYOUT WALL = XroI 2X I I �1 WAL LI A I_ I — — — �- ' L 'ono °0Q r — — —I o — 7a �� IRANGEI I jLAV. OPT. L--J LAV. - N i r l TUB — — — — — — — — — — — — — — — — — — — — — — ------------ OPTIONAL MSTR• CLOSET HURRICANE RESISTANT WELDED WIRE FABRI (oX&-U)2.1XW2.1 4" F0L T 5T1'fRENE z m GONC. 5LA8 2 #5's CONT. INTERIOR 5EARINC; WALL A _- NOTE: FOR FLOOR BEARING WALLS DO NOT INSTALL CONNECTORS. CONNECTORS ONLY NEEDED WHEN THERE IS UPLIFT ON WALL B u z BAKERS ,"...ROSSING LOT #137 PHASE MODEL: l9 1 7 3 2 L" FS/BC FOUNDATION/ DOWEL PLAN DATE: 6/30/03 SCALE: 1/41■1'-®' SHEET O P' IM BAKERS CROSSING ILOT #137 PHASE#21 MODEL: "1732- L" 6/12 ROOF FS. /BC LINTEL SCHEDULE DATE: 6/30/03 SCAT : 1/4181'-01 SHEET IAOF 5 a f, 16' - 0 " X 1' - 0 " O.H. O1 306D 8 R O 16 C= O (2)25-5H W1 W/SIDE LITE ARCH TOP ABV. O2 G=48"x10"xi4" 1� D= 35-SH W/ TRANS. ABV. 54"X20"X28" OD = 48"X48"X54" 3 E= TRANS. ASV. 35-SH W1 TRANS. ASV. 18 54"xIO"x16" 48"x3O"x3 O E= 6" 4 TRANS. ABV. TRANS. ABV. 1g F= (2)25-5H W1 60 "X38" 1/2 RND. ABV. ar,F= 48"x26"x51" TRANS. ABV. COMPONENT AND CLADDING WIND LOADS BASIC WIND EXPOSURE FOR 3 SECOND GUSTS CALL # SQUARE FOOTAGE WINDOW SEE AND TYPE ZONE0 0 MPH WIND MPH WIND 1 28 3068 DR W/SIDE LITE 4 .5/ -22.3 F214.3/ -26.5 2 5 48"x10"xl4" TRANS. ABV. 4 21.8/ -29.1 ELEV "C" 25.9/ -34.1 3 19 48"X48"X54" TRANS. ABV. 4 20.9/ -2-1 EL_EV "D" 24.8/ -32.6 4 12 48"x30"x36" TRANS. ASV. 4 21.6/ -281 ELEV Th 25.1/ -34.2 5 18 48"x26"x51" TRANS. ABV. 21/ -26.6 ELEV "1=" 24.8/ -32.9 6 112 GARAGE 16'0" X -i'0" 5 18.3/ -22.4 21.8/ -26.1 -f 1-1 25-6H 4 21.1/ -22.9 25.1/ -2-1.3 8 I-i 25-5H 4 21.1/ -22.9 25.1/ -2-1.3 9 11 25-5H 5 21.1 / -28.0 25.0/ -33.1 10 1-1 25-8H 4 21.1/ -22.9 25.1/ -21.3 11 I-1 25-SH 4 21.1/ -22.9 25.1/ -21.3 12 53 0068 5GD 4 19.4/ -24.4 23.1/ -29.2 13 10 23-5H 4 21.8/-23.6 25.9/-28.1 14 24 35-SH 4 20.9/-22.4 24.5/-261 15 24 35-SH 4 20.9/=22.4 24.5/-26.1 16 30 (2) 25-6H U1/ ARGH TOP 4 20.4/ -22.2 ELEV "C" 24.2/ -26.4 1-1 33 35-SH LU/ 54"X20"X28" TRANS. ASV. 4 20.2/ -22 ELEV "D" 24/ -26.2 18 28 35-5H W1 54"X10"X16" TRANS. ABV. 4 20.5/ -22.3 ELEV "E" 24.3/ -26.5 19 4-1 (2)25-SH W1 60"X38" 1/2 RND. ABV. 4 19.ro -21.4 ELEV "1=" L:2:3.4/ -25.6 BAKERS CROSSING ILOT #137 PHASE #21 MODEL: "1732- L" 6/12 ROOF FS. /BC WIND LO AD CALCULATIONS DATE: 6/30/03 SC AT: 1/4121'-01 SHEET JL OF 5 I JUL 0 1 2003 �t I � r OOFT.AfRCH OFEN ING 6 " PRE -CAST WALL 1R-ISH I 6" PRE -CAST WALL "'L-&" PRE -CAST WALL OFT CLOSET 'A Irk wr� 0 q)�CFT. POOL BATI--I 40' - 0" IK 9'-4" 11 10'-2" 2'-8" , 2 10'-10" v 10'-6" KNEE — 25_SH 2E� 25-SH SPACE EGRES EGRESS cv o o m I � I � LAV. OPEN v �' Q I to A SOVE Q Q 311 OWNERS m I O.BATH CD SUITE 9'-4" CLG 3" WALL 3ro" PALL PATIO 80(08 S.G.D. 2-4 NOOK 9'-4" CLG. (TILE) ^ — A (TILE) 1 m C 2" WALL� � Q 5< � ' m T'_TT. ITT�_r 12'-0" OPT. I 2 -4 3 INSULATION I z W.I . C . Q I� I = I cn 2X& WALL o o TILE I LAV OPT. BDRM. 3 I = LAV Iz-S HALL (CARPET) I m I BATH %s HC,ACC, -' N Lu `4 - BF. TUF3 c;, 5-SN �n = N I 0; 3'-0" 3'-ro" 4'-0" F5'-4" m R.A.G. La BDRM.#2 SOFFIT 9'-4" CLG. I —_ —_ FOR AC (CARPET) � I = m , RETURN LAUN I I 30°xz6" (TILE) z I N ® N F RANGE O oTL 0 I 9'-4" GLC�I I pp I FAMILY WATER HEATER IN `� I ^ -- J ROOM SAFTEY PAN I A.G. 9'-4" CLG. � PLATFORM (CARPET) - 3OX483 �GOND.1 WH. Fp 12'-0" ,2'-4" 5'-4" 4'-01' —2 2—" X 547_1 I ATTIC I LACCES _ J W/ OPTIONAL PULL DN. STAIRS 9'-4" CLG. 111 9'-4" GLG. ELEV. A,E3,C,G TILE LINE — — — — 13'-4" CLG ELEV. D,E,F , LINE OF CLG. — — — ELEV. D,E,F FOYER oo O(TILE) � 00 3.� LL MT. p H.R. � > ENTRY �I Lu — — — — — — iml ITT—Q V-0" X 1'-0" O.H. 3-0 DR. W/10" SIDELITE ELEV. C,D,E,F D = 4,5"x48"x54" AB`\/. E = 45"x30"x3&" A5V. BDRM.#4 6 DEN (CARPET) c0 9' - 4" CLG. ELEV. D,F VAULTED CLG. M ELEV. D,F ONLY 0 _I I � m 2'-8" IG '-0" 2'-10" 2'-4" 2'-4" 3'-0" 10'-10" 21'-(o" 40' - 0" F L 0 0 'F_ FLAN Ink mm I 01 I D= 35-6H W/ 54"X20"X28" TRANS. ABV. NO LINTEL REQUIERD E= 35-5H W/ 54"xl0 "xl&" TRANS. ABV. I i � z� VAULTEC Q �I tit ELEV. D,F cn w ENTRY eOl e I w l-- 45"46 "x51 ° (2) 25-61­1 W/ TRANS. Af5V. 60"X38" 1/2 RND. ABV NO LINTEL REQUIREC 10'-2" ELEV. 99 99 3-0 DR. W/10" SIDELITE ELEV. C FOYEf I00 CTILE I p CD w ENTR r- I � 48"xle TRANS. m vd, ELEV. "C" SQ.FT. CALC.'S LIVING GARAGE ENTRY fmATIO 1132 45(o 22 54 50. 50. 5Q. 50_ FT. FT. FT. FT_ TOTAL 2 2 �? 4 50- FT_ I BAKERS CROSSING LOT #137 PHASE #2 MODEL: 1732— L" 6/12 ROOF FS. /BC ]FLOOR PLAN DATE: 6/30/03 SCAT : V41=1'-®' SHEET 2 OF 5 AIL U 1 ZOO,J 9' - 4" 15RG. 0'-0" FIN. FLR. REAR ELEVATION 2 ST�JCCO BAND DETAIL 1 CRICKET 24" DECO. 12 LOUVER ro 14' - m" BRG- 2.5/12 VAULT LINE 9'-4" B9'-4" PRG. iG/11 0 11 TEXTURED FINISP 18" DEGO. SPUTTER 0'-0" r- N. FLR. , IL c6,0'-O" FIN. FLR. OFF-RIDGirz VENT FRONT ELEVATION OFF -RIDGE VENT 12 6 9'-4" BRG. I01 C TEXTURED ' FINISP m'-O" FIN. FLR. — — — — — — — — — — — — — — — 0'-0" FIN. FLR. RIGHT ELEVATION LEFT ELE'IT"ATIO11, 9'-4" 5Re. 0'-0" FIN. FLR. BAKERS CROSSING LOT #137 I PHASE #2 MODEL: "1732- L" 6/12 ]ROOF FS/BC ELEVATION" F" DATE: 6/30/03 SIC AT: SHEET 3 F OF 5 2X4 COLLAR TIE EVERY OTHER RAFTER 2X RAFTER 2-126 EVERY TRU66 IX6 NAILER-7 2X RIDGE U- y 3-12cl RAFTER TO NAILER 1/16O.S.B. _j IX& MAILER -J-- OF, 1/2" FLY. 2-126 EVERY TRUSS CONV. FRAMING DETAIL/VALLEY HEADER SPAN CHAFU eINGLE 5TORY APPLICATION SIZE GLEAR SPAN D5L 2X6 DBL 2X8 D5L 2XIO D5L 2XI2 UP TO 5'-4" 51-411 TO 11-011 11-011 TO 1011-011 10'-0" AND OVER TWO STORY APPLICATION DOWN STAIRS SIZE CLEAR SPAN D5L 2Xro D5L 2X8 D5L 2XIO D5L 2XI2 UP TO 5'-0" 5'-0" TO &'-4" 6l-4u TO all-oll V-0" AND OVER 4X4 PO6T=(2)2X4'5 NAILED WITH 126 &"-V O.C. STAGGERED 4Xro PO6T=(3)2X4'6 NAILED WITH 126 (o"-V O.C;.,5TAGGERE[;) _D5L 2 X 4 TOP PLATE 6F4 5F4 14'-0" E3fRaa ENTRY DBL. TOP PLATE MeTA-24,-if (2) 2 X (o E3M M5TA-24 X 4 EXTI_ WALL 'a ENTRY - 1 13-4" 5fRG.HGT.5L< D I ro 11 O.C. 1/2 X a" A-5OLT5 W/2' WASHER 1/2 " X 0" A.f5JLT6 3-EA. 5fDE TYP, W/2' WASHER 3-EA. SIDE TYP. MSTA-24 2 X12 5M M8TA-24 _(2) lNlSH 2 X 4 PT.OR 2 X 4 PT.OR 2 X 4 W1 VAPOR 2 X 4 W1 VAPOR BARRIER 0BARRIER 2 X 4 FT—, 5' GMU BLK 3/4" X 2" RECESS (6 - TYP.) ,LL 8" CMU 5LK 0'-0" FIN.FLR. KNEE WALL DETAIL@ENTRY WDW/DOOR DETAIL /_ 1-1,7) 1/01, @ HIP DETAIL M 11 1 1 IF 1­1 1 1 1 ILI L3 �H ��I I I'll I I I L1.1 m I if, - 77 II II rL- K= (2) META-lro Al A A13 All A13 AIF2 All A19 A A A A A A A A A A 22 "X54 ATTIC; A = I ACCESS Al Al A2 A2 AGI E3 ul - - - - - - - - - - -- (y- - i—if 7-- .TRUSS PLAN 10 AG2 HE * CONNECTORS TO BE SIMPSON U.N.O. * TRUSS TO 5L< META- 1(o W/12 - 106X] 1/2 * TRUSS TO WOOID MTS- 12 W/14- 106XI 1/2 2) META - l(o BAKERS CROSSING LOT #137 PHASE #21 MODEL: "1732-L" 6/12 ROOF FS/BC TRUSS PLAN D & F DATE:6/30/03 SCAT: V41mil-01 SHEET 4DF OF 5 a JUL o 1 2003 0 ELECTfRICAL LEGEND 5,t'IMI50L DEFINITION NOTES 11mV OUTLET I/2 OF OUTLET 110V OUTLET WIRED TO SWITCH EQUIPED WITH IIOV OUTLET GROUND FAULT GFI INTERUPTER (jf �I 220V OUTLET WP EXTERIOR GROUND FAULT GFI WATERPRO INTERUPTER OUTLET SWITCH It3 SWITCH 3-WAY OPERL -4 SWITCH 4-WAY OPER. WALL QMOUNTED LIGH CEILING LIGHT i l VAPOR PRO `OJVP LIGHT 1 RECE55ED `OJ CAN I CFM VENT. FAN SQ. FT. VENT_ FAN I CFM PER W/LIGHT SQ. FT. 2' LIGHT STRIP 4' LIGHT STRIP uuuuuu FLOURECENT RAP AROUN41:? LIGHT 2' FLouRECENT — — — — 4' FLOURECENT ® PANEL METER SMOKE GATT. BACK-UP W/ HARDWIRE DETECTOR INTER- CONNECTED PENDANT L IGHT TELEPHONE ® JACK WATER HEAT. WH D 15CONNECT AIR. COND. A/G DISCONNECT TV. TELEVISION JACK CEILING BOX TO QSUPPOR CEILING BE ED FAN/LIGHT IN ACCORDANCE W/ BOX MARKED AS SUCH FOR INSPECTION FLOOD L IGHT Ee INTERCOM I SPEAKER PATIO /'�P. GF I 1 OWNERS 0. BATH I SUITE I _ (o0 Y _ Yoe 0 \ KITCHEN /� J I GFI PRE -WIRE I I I— — lit,\ ZPRE - W I RE \ Q I G / Eo� W.I.C. I / �fo�'---Aro') l F o ono PRE -WIRE — I DINING m AREA a BDRM. 3qp \\ \ ELO / 0 / PRE -WIRE BDRM. #2 t` I UTIL. l0 / WP. \ I I —a _ / GF I Fq AA/C Fv�P� R/ E/ -/WIR PANEL E/z ,u , FAMILY ROOM t�r 44A.F. METER SAFT1PAN WALL MOUNTED LIGHT / / FIELD 4SWITCH IN ATTIC VERIFY FOYER \ I OS.D. , CLG. OUTLET GARAGE I PRE -WIRE FOR \ I BED RM4/DEN MIMES C ELECTRICAL PLAN LOC. OF T.V. AND PH. OUTLETS 4 FAN TO BE VERIFIED HOMEOWNER PRECONSTRUCTION MEETING NOTE: *ALL RECEPTACLES IN SLEEPING ROOMS TO SE ARC FAULT.(NEC 210-12) NOTE: #20 AMP DEDICATED LAUNDRY CIRCUIT. 4/0 ALU. GABLE 200 AMP METER BASE 4 SERVICE BY I I I—AL50 SERVICE 5/5" GROUND R TO BE BONDEDO POWER CO. TOFOOTING STEEL A/C DISC. ELECTf;ZC;AL FZGEF, 012 COPPER TO LIGHTS 4 OUTLETS 010 COPPER TO WATER HEATER #5 COPPER TO RANGE NOTE: ELECTRICAL MATERIALS AND INSTALLATIONS SHALL COMPLY W/ APPLICABLE PROVISIONS OF THE NATIONAL ELEC. CODE, LOCAL CODES, AND THE LOCAL POWER CO. 3 —1,'. PLUMBING RISER KITCHEN SINK W/ AUTO VENT TO MAIN BAKERS CROSSING LOT #137 PHASE #2 MODEL: "l 732- L>> 6/12 ROOF FS /R C ELECTRICAL P LAN DATE: 6/30/03 SC AT: 1/41811,01 SHEET 5 ®F 5 v JULV 1 2003 D 1/2 11 X 911 A.B. 3211 O.C. _ /o"Xro 1, #1 D W.W.M. (o ° EMBEDMENT MIN. (o" EMBEDMENT 1/2" X 9" z q WHEN UPLIFT FROM ROOF ANCHOR BOLTS AT 3' O.C. 2" ABV. CONC. CONC. SLAB - 60 " #10 W.W.M. 41 (2) CONT. #5 REBARS2 #E✓''S CONT. 4 4 I ° 8 7��2� 1'-0" m _ CONC. SLAB ? `� 411 �{II II_QII 4II _ /o`` 3 #5 s CONT. CJ TNIGKN EI�C-: 0 0 U m 11_411 2-#5'S ON CHAIRS GARAGE CURB STOP TYP. WALL SECTION INTERIOR BEARING WALL INTERIOR BEAFR NG WALL 2 -STORY � 2 2A BLK. SINGLE STORY NOTE: FOR FLOOR BEARING WALLS NOTE: FOR FLOOR BEARING WALLS DO NOT INSTALL CONNECTORS. WOOD FRAME FOOTING CONNECTORS ONLY NEEDED WHEN THERE DO NOT INSTALL CONNECTORS. fS UPLIFT ON WALL CONNECTORS ONLY NEEDED WHEN THERE IS UPLIFT ON WALL 3 1/2 11 4 4EAD OF GARAGE 3 1//2 " HEAD OF GARAGE �-.-#5 DOWEL BAR(ONE SIDE / #5 DOWEL BARS #5 DOWEL BARS (VARIES W744 SLOPE) (VARIES WITH SLOPE) OF DOOR IF NEEDED) r DIM VARIES 7 5/8" z DIM VARIES 9" ANCHOR BOLTS AT 3' O.C. -1 5/S" cuff B �� 6 "x6 ii #10 W.W.M. -1 5/S" CURB �� ro "X(oI' #IID W.W.M. CURB �� 6 "X6" #10 W.W.M. (3) # 5 RODS EA. WAY ON 8" C1"IU 9 ANCHOR BOLTS AT 3 O.C. MIN 6" EMBEDMENT ONLY IF UPLIFT ON WALL ( IIX/ ll #10 W.W.M. rCHAIRS (MIN. 3" COVER) MIN 6" EMBEDMENT EXTEND 1 1/2 �_� II 6 "X6'l #10 W.W.M. "--"-.-:� = z w - - z LU --.. 4 RECESS /2" `� Y_ > II `� Y_ > II GRADE SLIDING DOOR TRACK -------- 1n v �� 2-#5'5 ON CHAIRS U �� (3-5'5 W/2-STORY) m o 0 0 2-#5'S ON CHAIRS I'-4" m SLOPE GONG. G ° m SINGLE (3-5'S W/2-STORY) SINCzL TO FRONT(1/4" -1/2 `) I'-811 3 #5'S ON CHAIRS STORY 2 0 1 1/2 11 STORY 2 #5'S ON CHAIRS TWO TWO 9 1/2 INSIGNE FTC. AT GARAGE StEP-UP STORY STORY 2-61iORY BEARING WALL GARAGE SERVICE/POOL GARAGE CURB GARAGE CURB SLAB AT SL. GLASS DOOR INSIDE FTC. AT GARACxE STEP-UP 24"X24" EXT PAD 1 STORY BEARING WALL DOOR RECESS 8 �A 1 CONC. SLAB OVER GLEAN, COMPACT TERMITE TREATED "5 REBAR SET IN 2000 OL L, MIL. V15. VAPOR � FLAB/�O MIN " MIN. AE EMBEDMENT TOP CORD BLOCKING AT 4' O.G. MAX. IN FIRST 2 FRAMING -� II 611X6" #10 W.W.M. SPACES AT EACH END. GARAGE SLAB � 6"X6" #10 W.W.M. �, u RAFTER OR TRUSS NAILING SQHE®ULE ALL NOTES IN REFERENCE %- ROOF SNEAT�-IfNC� LAYOUT ROOF SHEATHING \� ROOpDIAPHRAt1 TO FLORIC.�A BUILDING CURB WALL 8° GONG. DRIVEWAY GARAGE BEYOUND o o- o 1 _g 3 #5 s CONT. 3 MIN. COVER O ° TYP" RETROFIT FOR ALL �� OMITTED FOUNDATION DOWELS l I A ANp ENDWALL BRAGING FOR GABLE END FRAMING � Z Q I USE VI6'O.B.B.ORIR'FLY WITH -5S"NAILS AT4'Or-AT �®�E 2001 SMEDEfATE SUUMPOWS. ALSO BEE �DE AIL.NAILAT 6' OC. AT ROOF 8HEATHMG TO GABLE END FROM EXTERIOR BHEA7 �NAILB s 4' O.C. SITE PLAN NOTES V V I \ � PANEL US' IDES AND 0.515OR 09 GLAI NAILS •4'' Or- TOP NAILS '4BOTTOOM.C' AT ca PANEL AND IS GUN NAILS AT 6' OG. AT 1) LOWEST SLAB AT LIVING AREA SHALL BE MINIMUM IS' ABOVE GARAGE DOOR BUILDING LENGTH MTErd"IEDIATE BUPPORT6. ALSO SEE DETAIL. GROWN OF FRONTAGE ROAD OR AS NOTED ON PLANS. NOTE: GUN NAILS SHALL BE PERMITTED AS AN 2) UNLESS OTHERWISE NOTED, THI5 BUILDING IS NOT INTENDED TO BE OPEN f NG ACCEPTABLE FASTENER FROM ANY MANUFACTURER CONSTRUCTED WITHIN A FLOOD ZONE REQUIRING A FIN15H FLR. ELEVATION 1 1 2 -STORY FOOTING ABV. 10.5' MEAN SEA LEVEL. CONTRACTOR SHALL VERIFY ELEVATION I I I I NAIL REQUIREMENTS OF FINISH FLOOR SLAB WITH SIGNED AND•SEALED SURVEY_ _ SIZE HEAP LENCsHT PIA. TEN51L STR AND RESTRICTIONS HAVING JURISDICTION. 4) ALL CN-SITE DRAINAGE SHALL BE DIRECTED BY SWALES OR OTHER SYSTEMS TO AN OFF -BITE DRAINAGE FACILITY. I ­OIiII_ looll_ATI/lAl CLCO Ilkl C aunt I /` I=nGW1 T/] I eV -Al ed ROUNDI" IOPIFIED OR T 1 -1/8' .113 110,000 lOd 2 I/8' 128 110f000 Sd GUN NAILS 4" O.G. # -. -IDES,', IZ,4T__I..-,I..I_ III.- �,.. # a� NOTE: NAILS TO BE MFG. BY MEMBER OF INT. CODES, REGULATIONS ANP RESTRICTIONS HAvfNG JURISDICTIONS AND 8d GUN NAILS ') STAPLENAIL 4 TOOL ASSOCIATION AS SELECTED BY BUILDER -IATED WORK TOP BOTTOM EDGES 6) O.C. IN FIELD GENERAL NOTES 6) SWIMMING POOL, A, AND ASSOC PERMITTED SEPARATE YPBY ENGINEERED SHOP ISOSBE POURED LENTIL CONT. (TYP) II II I. DESIGN AND LOADING C .;a A. ALLOWABLE UNIT STRESS AND DESINCs CRITERIA: PLUMBING NOTE S II @ N I. BUILDING COPE REQUIRMENT6 FOR REINFORCED CONCRETE AGI 318 e < 2 X WALL FRAMING t� Q Q 2. FLORIDA BUILDING CODE 20101 TO BE II I) I w LLI -A - 1U 3. WIND SPEEDS 110-120 (PERWIIND SPEED MAP) 1) SANITARY LINES SHALL BE OF CAST IRON, OR PVC (SCHEDULE 40) (3) 1/2 "XV ANCHO%: BOLTS I OUTS 1DE BAR - IU 44 WIC IMPORTANCEXPOSURE E ACTOR (U A6 APPROVED BY THE BUILDING OFFICIAL. 8 GMU FILLED o or (3) 1/2 XS J-BO?LTS REBAR II II _q Q z U 6. INTERNAL PRESSURE CO -EFFICIENT +15 THF&I -18 2) WATER LINES SHALL BE CPvC. CELL (Ti-P") , p -�` MIN. 6" EMBEDMENT II ,Z� Lu z Z Z Q 2. SOIL 3) CONDENSATE LINES SHALL BE MIN. 3/4' DIAMETER PVC W/ 211X2 "X1/S WASHER' AND = _ _ _ _ �� �� CONTINUOUS z @ z A. NET ALLOWABLE 501L BEARING FRE55URE USED IN DE51GN 2000 PSI FOR (SCHEDULE 40), INSULATED WITH 1/2' AMAFLEX CONTINUOUS WALL FOOTINGS. �Y 4) PROVIDE AIR CHAMBER FOR ALL WATER SUPPLIES. NUT SPACED EVENLY FROM - U 3. CONCRETE AND REINFORCING TROL DEVICE TO GIVE EXT. FRAME WALL TO = _ = s = = U 10 @ A. ALL CONCRETE WORK SHALL BE fN ACCORDANCE WITH AGI 31B AND WITH FLOOR TO BOND BEAM. SET (� O # SPECIFICATIONS FOR 5TWTURAL CONCRETE BUILDING ACI 301. 5J MAXIMUM M FLOW OF (3ER HEADS TO THREE GALLVE FLOW ONS PER MINUTE EACH. BLOCK WALL: CONNECTION IN JOINTS PRIOR TO FILLING- #-T-T/�. IEI EXTERIOR OR SHEATHING I I * � B. PSI ICONCRETE DAYS SHALL DEVOLOP MINIMUM COMPRESSIVE ST�NGTH OF 2500 6) NOSE BIBS TO BE PROVIDED WITH BAGKFLOW PREVENTER (SLEEVED ANCHOR IN SOLID �Q A I I /-' CHt'-1E �lT FOR ROOF- 5HEATH ING C. REINFORCING BARS SHALL CONFORM TO ASIM A615 All OR ell, GRADE 4O -1) ELECTRIC WATER HEATER 514ALL HAVE A STANDBY LOSS NOT TO POUR ACCEPTABLE: RETROFIT) 25" MIN. LAP @ 4. DESIGN LOADS NOTE -, A IN ACCORDANCE WITH FLORIDA BUILDING GOpE 2001 CHAPTER 16 EXCEED 4.0 WATTS PER SQUARE FOOT of LANK SURFACE AREA. TYP, REBAR LAP @ WHEN II I I }� ROOF LIVE LOADS OF 20 P5F 8) PLUMBING FIXTURES, TRIM, ACCESSORIES, COLORS, ETC. SHALL W CORNERS HEN GLUED TO ROOF MEMBER BE SELECTED BY OWNER FROM BUILDER'S OFFERINGS. / II - Q II @ E DGE L+ 4 10" _ 12 " IN EE I L D 5. LUMBER 13) ALL POOL PLUMBING AND RELATED EQUIPMENT SHALL GROUTED Z KJ CJ l�l `J SL/ A. ALL STRUCTUAL LUMBER SHALL BE'2 SYP. ALL STUDS SHALL BE STUD GRADE SPF. BE PROVIDED BY POOL CONTRACTOR AND SHALL BE PERMITTED BOND BEAM 2 -#5's REBAR a 1 STORY TALL LUMBER EXPOSED TO WEATHER OR AGAINST BOIL, CONCRETE OR MASONARY SEPARATELY, SEE POOL CONTRACTOR'S ENGINEERED SHOP DRAWINGS.PLUMBING CONTRACTOR SHALL PROVIDE TWO COPIES OF 'AS -BUILT' TIE TO NORz. BARS LU 3-05 s REBAR 2 STORY SHALL BE PRESSURE TREATED) 8" MIN. EMBEDMENT �" T"I'P. EXTERIOR ePEATN INCH ATTAGI4MENT Ttd)SSES RISER DIAGRAMS AMC) PLAN LOCATIONS TO OWNER A FLORIDA BUILDINGS CODE 2005ES SHALL BE DESIGNED IN ACCORDANCE WITH 10) ALL GLE.4NOUT5 FLUSH WITH GRADE. FOR SHEAR AND UPLIFT TRUSS MANUFACTURER SHALL SUBMIT SIGNED AND SEALED DRAWINGS FOR APPROVAL 11) NO VENT STACKS SHALL PASS THROUGH ROOF CRICKETS, VALLEYS, (O.S.B. TO BE STRUCTURAL GRADE) PRIOR TO FABRICATION. RIDGES. HORZ. REINFORCING7.1 VERT. REINF. GARAGE DOOR 12) 51ZE AND LOCATION OF CLEANOUT5 SHALL CONFORM TO FLORIDA 6 NOOKIN GROUTED CONNECTORS FROM PLATE TO STUD TO PLATE A. B. DETAIL ENGINEERED O BE SUPPLIED 120 MPW BYIND 663 SE DOOR SUPPLIER PLUMBING CODE CURRENT EDITION. CELL ARE NOT REQUIRED EXCEPT AT OPENINGS C. DETAIL TO BE ATTACHED TO PERMIT PACKAGE BY BUILDER 13) FIXTURE SUPPLY SIZES SHALL CONFORM To FLORIDA BUILDING coDE 8. ASPHALT SHINGLES 2001. + #Sd GUN NAILS A. ROOFING TO COMPLY W/ FLORIDA BUILDING CODE 2001 A �A � O � R f N� O �1„i A � f O N 12 " O.C. I N FIELD B. SHINGLE STANDARD ASTM D-225, UNDERLAYMENT t0 BE ASTM D-226 14) PLUMBER TO DIVERT ALL VENTS TO REAR ELEVATION WHEN POSSIBLE. cn 15J ALL WATER CLOSETS SHALL BE WATER SAVING lb GALLON FLUSH TYPE FO U N COATI O N N OTE BLOCK NOTES CUEANOUT REQ'D 1. FOUNDATION DESIGN BASED ON 2000 P.S.F. MIN. ALLOWABLE BEARING N . �� a FOR / ROI IT LIFT Q PRESSURE. I. CONCRETE MASONRY UNITS SHALL BE HOLLOW CORE OR 8OLIp UNIT 'd ' ; . , ` t� 1.1 a - J j� 2. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH AGI 301 AND MASONARY IN ACCORDANCE WITH A87M G90 AND CI45 AND SHALL +• ' - -�' • - •- > 5 FT. UNLESS ` POURED LENTIL HAVE A NET AREA COMMPRESSIVE STRENG44T OF 11300 PSI. I I 'Q SHOP DRAWINGS WITH ACI 315. SHOP DRAWINGS SHALL BE SUBMITTED MORTAR HORZ. RE INFORGING Z �/ FOOTING DWL 16 O , GONT. (TYP) Z U TO ARCHITECT FOR APPROVAL PRIOR TO FABRICATION OR CONC. POUR. 1. MORTAR SHALL BE TYPE N IN ACCORDANCE WITH ASTM C210. METAL ACCESSORIES / II NOOK LU N01T REQ ID. ��� Z O ' ' 3. CONCRETE 28 DAY STRENCGHT SHALL BE 2500 PSI W/ 3/4' MAXIMUM I. JOINT REINFORCEMENT, ANCHORS AND TIES SHALL CONFORM TO THE KJ } _ AGGREGATE FOLLOWING: a ; SIDES: A. A5TM A82 FOR JOINT REINFORCEMENT AND WIRE ANCHORS. HORIZONTAL/VERTICAL RE ENFORCING c(1 0 PRE -CAST HDR. 4. ALL SLABS SHALL BE MIN. 3 I/2, THICK CONCRETE OVER 6 MIL VAPOR B. ASTMA36 FOR PLATE, HEADED AND BENT BAR ANCHORS. 2X�o GARAGE DOOR BUCK U)/ BARRIER OVER CLEAN WELL COMPACTED TERMITED TREATED SOIL. G. ASTM A366 FOR SHEET METAL ANcHoR6 AND TIES. # @ 2. METAL PLATES, CONNECTORS, SCREWS, BOLTS AND NAILS EXPOSED (3) 1/2 "X8" ANCHOR BOLTS 5. REINFORCED STEEL: ASTM A615, GRADE 40. VERTICAL REINFORCEMENT o` or C3) 1/2 "XS" J-BOLTS TYP. FLOOR DECKING SHALL BE 05 DOWEL BARS W/ A 6' HOOK PER DOWEL PLAN LAYOUT. DIRECTLY TO THE WEATHER OR SUBJECT TO SALT CORROSION SHALL ALL CORNERS AND OPENINGS GREATER THAN 6 BE STAINLESS STEEL OR DIPPED GALVANIZED MEETING THE . TIE PERT. DOWELS TO REQUIREMENTS OF ASTM A90. (o ° EMBEDMENT MIN. ATTACHMENT TO FLOOR JOIST HORIZ. BARS AND LAP VERTICAL BARS TO DOWELS MIN. 25'. MASONRY WOW., GENERAL: W/ 2'X2 "X1/S WASHER AND fo. ANCHOR BOLTS SHALL BE LOCATED ON EACH SIDE OF ALL WOOD I. ALL MORTAR JOINTS FOR HOLLOW MASORY UNITS SHALL EXTEND THE all GMU FILLED NUT SPACED EVENLY FROM EA. SKEET TO BE GLUED AT ALL FRAME SHEAR WALL OPENINGS AND SHALL BE 1/Vx8' W/ 2'x2'x1/8" FULL WIDTH OF FACE SHELLS. MORTAR JOINTS FOR SOLID MASONRY CELL (TYP.) FLOOR TO GARAGE DOOR HDR AT 3' O.C. STARTING AT 8' OFF EACH CORNER MASONRY UNITS SHALL BE FULL HEAD AND BED JOINTS. � X PO S E D JOIST 2. BED AND HEAD JOINTS SHALL BE 3/8' THICK. 1. DESIGN LOADS: IN ACCORDANCE W/FLORIDA BUILDING CODE 2001 3. MASONRY WALLS SHALL BE RUNNING OR STACK BOND CONSTRUCTION. IN JOINTS PRIOR TO FILLING. ROOF LIVE LOAD: 20 PSF WHEN MASONARY UNITS ARE LAID STACK BOND, S GAGE HORIZONTAL WIND LOADS: IN ACCORDANCE W/FLORIDA BUILDING CODE 2001 JOINT REINFORCEMENT, IN ADDITION TO VERTICAL REINFORCEMENT 1-2X6 PT BLOCK '� CENTER OF PER WIND MAP. REIN o�IrE•1�PSTEELD, GENERAL JOINTS AT NOT MORE THAN6 IN BED 1 8. FOOTING REINFORCING SHALL BE 2-05 REBARS 1-STORY, DOOR HEADER W/(1) 3"-5 REBAR 2-STORY. OUTER BAR MUST BE CONTINUOUS AROUND 1. REINFORCING STEEL SHALL BE No. 5 BARS. CORNERS. USE CORNER BARS OR BEND REBAR LAP A 2. WHEN 2 BARS ARE IN THE SAME CELL THEY MAY B LED. (1) 1/2 XS ANCHOR BOLTS 3. SPLICE LENGTHS SHALL BE A MINIMUM OF 25". MINIMUM OF 25. or (1) 1/2 "XS" J - BOLI I-OJ 4. REINFORCING STEEL SHALL BE MINIMUM GRADE 4 A CERTIFIED IN ACCORDANCE WITH ASTM A615, A616, A611, OR "1 �� 9. ALL FOOTINGS ELEVATION MUST BE 12' BELOW 6 EMBEDMENT FINISH GRADE W/ 2'X211X118 WASHER ANC) NUT 10. FINISH SLAB TO BE 6' ABV. FINISH GRADE BAKERS CROSSING LOT #137 PHASE #2 MONOLITHIC BLOCK DETAILS NOTES DATE: 6/30/03 SCiAI-w: 1/41=I1-01 :SHEET D 1 OF 4 11 d MAXIMUM HEADER SPAN (Ft.) UP TO 5'-0" TO S'-m' 4'-I1 1/2' -1'-11 1/2 AND UP NUMBER OF HEADER STUDS SUPPORTING END OF HEADER 1 2 3 NUMBER OF FULL LENGHT STUDS j AT EACH END OF HEADER I7_2 3 2X4 SUB -BAND a HURRICANE STRAPS CHASE GROVES,WAVERLEE WOODS 2X4 SUB -BAND Q 2X4 SUB -BAND Q FEILD STREAM CHASE GROVES,WAVERLEE WOODS (SEE TRUSS PLAN CHASE GROVES,WAVERLEE WOODS 2"X4" BLOCKING 2X6 SUB -BAND 10 FEILD STREAM FOR CONNECTOR) FEILD STREAM FIRST TWO BAYS LAKE KEHOE,CYPRESS HEAD 2X6 SUB -BAND @ 2X6 SUB -BAND METAL LATH ALOMA WOODS LAKE KEHOE CYPRESS HEAD LAKE KEHOE CYPRESS HEAD 4 -0" O.G. MAX WRAPPED/ALUM FINISHED FASCIA ALOMA WOODS —ROOF TRUSSES ALOMA WOODS ASPHALT SHINGLES WRAPPED/ALUM FINISHED FASCIA 2 4 " O.C. WRAPPED/ALUM FINISHED FASCIA OVER 1115 FELT OVER 1/16" OSB OR -1/8" TEXTURED ASPHALT SHINGLES. METAL DRIP EDGE 1/16" OSB SHEATHING 1/2" PLYWOOD FINISH OVER 015 FELT /- R-19 INSULATION FIBERGLASS SHINGLES __ R-19 INSULATION OR 1/2" FLY. W/ 15# FELT 1/16" OSB. SHEATHING ON #15 FELT OVER OR 1/2 PLY. 3/4" T 4 G PLYWOOD 2X4(CONT.) 7/16 OSB. SHEATHING SEE TRUSS ENG. -o - ROOF TRUSSES HURRICANE STRAPS TO BE GLUED (SEE TRUSS PLAN METAL DRIP EDGE FOR PROPER 2 4 " O.G. 4 NAILED FOR CONNECTOR) 1/2" CLG. BOARD & TEXT. 2X4 DOUBLE PLATE (TYP.) 2X4 SPF STfFFBAGK AT BRACING O (1 5 CONT. LL UPRIGHTS OVER 4'-10" HET METAL DRIP EDGE B DD ALUM. FINISHED VENTED SOFFIT No LINTELSTRAP 1X2 FURR STRIPS SEE TRUSS PLAN FOR CONNECTOR SILL ENG. GABLE TRUSS ALUM. FINISHED VENTED SOFFft 1/2' CLG 50ARD 4 TEXT. 1/5" TEXTURED FIN15HIn 8" LINTEL BLOCK FILLED ° ALUM. WINDOW # 1/2" DRYWALL SEE FLR./ELEV FOR DES. WOOD BASE (TYP.) OVER 15 FELT OVER R-19 INSULATION TEXTURED PRE -CAST LINTEL -1/S"TEXTURED FINISH ON 3/4" T 4 G PLYWOOD 1/16" O.S.B.OF, 1 2THCMU'S FLY --- FINISH FELT 5ARRIER OVER GLUED 4 NAILED ALUM. WINDOW -1/16" 055 SHEATHING OR 1/2" PLY. SEE FLR./ELEV FOR DES. SILL (SHEATHING MUST BREAK MIN. 1'-4" FLOOR JOISt/FLOOR TRUSS PRE -CAST SILL 2X PLATE SECURE 1 FROM 2nd FLR. LINE) /2" CLG. BOARD 4 TEXT. SEE FRAME PLANS TO DBL TOP PLATE 5I W/ 0 0 S IMPSON HTC - 4 32 " O.C. MAX. ® 1/2" DRYWALL 2X4 RE-FORCEMENT (CONT.) JOIST TYPE MSTA-24 24" O.C. MAXA 2X4 DOUBLE PLATE (TYP.) 2X4 NAILER (CONT.) TRUSS S" CMU R-4.2 INSULATION O (I) S CONT. FOR NDR SIZ�AN 1X2 P.T. FURRING STRIPS FLR JSETTTOI BLK 1X2 FURRING STRIPS BAND DETAIL ALUM. WINDOW TEXTURED FINISH 1/4° WOOD BASE ° o I/2" DRYWALL SEE FLR./ELEV FOR DES. SILL S LINTEL BLOCK FILLED 1/16" OSB SHEATHING WOOD BASE (TYP.) PRE -CAST LINTEL OR 1/2" PLY. UNDER :1-A, _:: � FELT FARRIER p � PRE-FAB TRUSS 4 ALUM. WINDOW FLOOR JOIST/ (�rollxroll #10 W.W.M. SEE FLR./ELEV FOR DES. SILL FLOOR TRUSS 1/2" CLG. BOARD 4 TEXT. OR FIBER MESH FOR JOISTETPPENS SP-4 32" O.G. STUD 2X4 DBL. TOP PLATE 0 REINFORCEMENT PRE -CAST SILL CONC. SLAB OVER GLEAN, HETA-16 ",w 32" O. C. MAX 1/2" CLG. BOARD TEXT . 1/2" DRYUJALL COMPAGT,TERMITE TREATED O (1/*5 CONT. z z w SOIL OVER 6 MIL V15. VAPOR 2X4 WOOD STUDS NY_ 0 1 _4 2 #5 CONT. S GMU BARRIER,W/6X6 #10 WWM 8 LINTEL (IL c;KED 1X2 FURRING STRIPS 2X4 CONT. STRESS �16" O.C. A TEXTURED FINISH 1/4° PRE -CAST LINTEL _No- ° ° 1/2" DRYWALL BLOCKING MID -WALL WOOD BASE (TYP.) 2X4 PT. PLATE - c, 5P-4 32" O.C. s STUD 1/2"XS" A.B. 32" O.C. z ALUM. WINDOW (WHEN UPL IFT� 6" EMBEDMENT T'rP. WALL SECTION'(7 SEE FLR./ELEV FOR DES. SILL BL< 1= STOR"r L WOOD BASE (TYP.) CONC. 5LA8 z rO"X6" #10 W.W.M. PRE -CAST SILL �'- 4 4" - z (k 3 #5's CONT OR FIBER MESH CONC. SLAB 2 #5's CONT. z w RE INFORCF_MENt 1' - 4" m N 0 m0 1'-8" all cMu 6 MIL V16 VAPOR BARRIER INTEi�IOR BEA�f1�1C-� WALL TEXTURED FINISH 1/4" ASPHALT SHINGLES OVER TYF. WALL SECTION NOTE: FOR WALLS W/FLOOR LOAD ONLY #15 FELT ON -i/16" O.S.F. 2 0 c� > DO NOT INSTALL CONNECTORS. SHEATHING OR I/2 PLY 2 "X4" BLOCKING _ ~ � FIRST TWO BAYS 2 - STOF,"r z METAL DRIP EDGE 4'-0" O..C. MAX 6 "X6" #10 W.W.M. 2X4 DBL TOP PLATE 2X4 SUB -BAND Q O O RE RE FIBER ME',SH .�. INFORGEMENT CHASE GROVES,WAVERLEE WOODS SEE TRUSS ENG. FEILD STREAM FOR PROPER ROOF FRAMING W/ CONNECOR& Z Lu z 2X6 SUB -BAND (SEE TRUSS PLAN) } — } LAKE KEHOE,CYPRESS HEAD Lu BRACING 0 0 (3) #5 s GONT 1/2" DRY WALL ALOMA WOODS ROOF TRUSSEa S DBL. TOP PLATE `�' U U WRAPPED/ALUM FINISHED FASCIA 2 4 " O.C. ENG, GABLE TRUSS R-19 INSULATION CRIPPLE STUDS F(fic'ST FLOOR BLOCK 2X4 SPF STIFFBACK AT SECOND FLOOR FRAME -i/16° os ALL UPRIGHTS OVER 4'-10" 2X4 16" O.C. MAX (SEE TRUSS ENG. FOR SIZE) HEADER (SEE PLANS) 1/0" TEXTURED FINISH OVER 15# FELT OVER 1/2" CLG. BOARD 4 TEXT. PRE -FAB TRU55 2X4 PT. 2 "X4" NAILER CONT, 1/2" CLG. BOARD 4 TEXT. TEXTURED FINISH -1/I�o" O.S.B. SNEATHINCa � BT. PLATE OR 1/2" PLY. C2) LAYERS �/16 L o.s.B.sEcuRE EA, /16 5P-4 32" O.G. ia STUD 2X4 DBL. TOP PLATE LATHAOY R TYVFK 1/2 x 9 A.B W/ MIN. 6" EMBEDMENT 2x4 P.T. PLATE W/ o W/2 Sd,s 5"-12" O.C. -ir— HIDR STUpCS)/JAGKCS) 1/2" DfRYWALL OF 15 FELT r 2" DIA. WASHER 1/2 "X9" ANCHOR BOLTS MAX. MIN. 6" EMBEDMENT 1/2" X 9" A.B OR J-BOLT LSTA 12 2X4 WOOD STUDS #5 REBAR CONT. STUD TO HDR. FULL LENGTH STUD(S)/ 2X4 CONT. STRESS '�lro" O_C_ ..•: r" W/2 p IA. AT 32 O. C. � 32 O.C.MA�C • f ; r ,; SECURE TRUSS TO 2X6 W/ KING STUD(S) 5P-4 BLOCKING MID -WALL 12d e 6"-a" CONC. (FILLED LINTEL TOP BOTTOM) 3/4" TOG SUBFLOOR ; ..;.:�•• PLYWOOD TO TRUSS NAILING BLK. REINF. WITH (1/'5 ROD C-�LUED 4 NAILED 4" O. C. e EDGE I j' 6" O. C. a IN FEILD ,•a all cMU FLR. J5T. SIZE SEE FRAME PLAN '�,r-�;�: 14 TEXTURE FINISH IX2 P.T. FURRING STRIPS SHEATHING OVER 2X4' •' ' R-4.2 INSULATION NAIL PER SCHEDULE 2nd FLR, STUD TO i/2" CLG. BOARD TEXT. 1st FLR. STUD 2X4 DBL. TOP PLATE 1.000D F�'Al~'C TO BLf<. 1/2" DRYWALL — — — -1 r — — — — — - - -I MSTA-3(o 32" O.C. 1/2" F-)FY JALL 2X4 WOOD STUDS 2X4 GONT. STRE55 e16 " O.C. WOOD BASE I I I I I I BLOCKING MID -WALL II II I I I 2X4 PT. PLATE X I I I I I NAIL PER SCHEDULE/ 0 � � ---- I I I I I BOLT PER FND. PLAN SP-4 32" O.G. � STUD—� 1/2"X9" A.B. 32" O.C. MIN. 6" EMBEDMENT z O - Z O 6 ">C(o" #10 W.W.M. 0 0 OR'FIBER MESH C�#'B4°"4'l 2X4 COLLAR TIE �2X8 RIDGE �} 0 REIINFORCEMENT TAP EXTERIOR OPENING IN FRAME 5s CONT.I' S„ EVERY OTHER RAFTER tL L _ 2 #5 CO)NT. U • 1-4 Z Ilk T'I'P. WALL SECTION 2-STOi��1' 2-126 EVERY TRUSS 3-12d RAFTE INTERIOR BEARING WALL 1X6 NAILER 3-12d TO NAILER NOTE: FOR FLOOR BEARING WALLS DO NOT INSTALL CONNECTORS. -1/1(0" O.S_B. IXO NAILER 1 OR I/2" PLY. 2-12d EVERY TRUSS BL< 1-STORE (CABLE) MINIMUM WALL ANF) HEADER GONV. FRAMING [DETAIL/VAS/ STUD R QU• I R1"INT5 fill BAKERS CROSSING LOT #137 PHASE #2 MONOLITHIC BLOCK DETAILS & NOTES DATE: 6/30/03 SCALE: V41211-01 SHEET 2 ®F 4 L u 1 2003 4 A # IOOO UFLIPT 51MP5OM MT5-12 W/-i 10d TO TRUSS AND (2)1/4" X 1 3/4" TAP CONS TO GONT POURED LINTEL # 2000 UFL IFT (2)51MPSOM MT5-12 ONE EA. 51DE OE TRL OPPOSITE SIDE OF E Y W/-i 10d TO TRUSS AND (2)1/4" X 1 3/4" TAP CONS TO CONT POURED LINTEL 'RU55 3 BOND BEAM TRUSS ANCHOfR IDTA I L = fRTROF I T 9" MIN. LESS THAN 10' REQUIRES 1' NOSING DBL ZXIZ - FLOOR J015T J/T I 1.. I WVVV WITH 4 160 COMMONS NAILED THRU 3/4" PLYWOOD INTO EACH STRINGER NOTE STAIRS RISERS TO CONFORM TO FBC 2001 2R+IT=24'-25' 3/16' MAX. VARIATION IN RISERS/TREADS ADJACENT TO EACH OTHER 3/5' MAX. VARIATION IN ANY R15ER/TREAD HANDRAIL CIRCULAR CROSS SECTION DIA. TO BE 1 3/4' +-1/4" OR PROVIDE EQUIVALENT GRASPA31 L I TY WINDERS- MIN. 6' WIDE im NARROW END MIN. 11' WIDTH 6 12' FROM NARROW END 34' MIN. HANDRAIL HGT. IX2 PT.TOP OF BOX DBL. TOP PLATE 2X4 6TUp 7/1Fi' OR 15/32' O.SB. Wn/a' TEXTURED FINISHED OVER GALVINIZED METAL - — — — PAPER BACK LATH SIMPSON H-5 (MIN-) ® 2X4 TO TRUSS PRE. ENG. TRUSS 2X4 BTM. PLATE 3/4" PLYWOOD 2X12 TREAD CUT Tc0 FIT - 1Xa IRISER LESS THON 4' TYP. BETWEEN `,SPINDLES II I-- ---SP4 OR H-5 TOP PLATE TO STUDS V-0' ABV. 10'-0' LEVEL TO ROOF OR 2'-0' ABV. HIGHEST RIDGE WITHIN 2'-0' 10'-0° FRAMED CRICKET FINISH m LANDING 1211 Z NAND 1/2' D I' NOSING TYP. 4 r STAIfR G CTION [DETAILS CHlt-(INE"� �)ETAIL5 SIMPSON H-5 (MIN.) e 2X4 TO TRUSS SECTION PRE. ENG. TRUE IX2 PT.TOP OF I D5L. TOP PLA" T/16' OR 15/32' Wn/a' TEXTURE FINISHED OVER GALVINIZp M)= PAPER SACK 1 CRICKET 2'-5-1/2" FLAN VIEW 2X4 STUDS FROM TRU66 6TUp6 TO IDM. PLATES Ai3V. 36" MIN. FINISH STAIF, UJINtDfR [DETAIL ASPHALT SHINGLES OVER * 15 FELT ON 1/16' O.S.B. — (2) 2X4 $2 ND SYP DIAGONAIL BRACE / W/ 3-12d e EA TRUSS ( DIAGONAIL BRACE TO COVER 5-TRUSSES 2X4 BLOCKING FIRST 2 BAYS 2) NLSENImd AIEA D TO TRU56 2X4 5YP 5TIFF5ACK AT ALL UPRIGHTS OVER 4'-10' 7/16" OSB SHEATHING USE ad NAILS AT 4' o-c. EDGE 4 6" 0.0. FIELD 2X6 PT. PLATE BOLT W/ 1/2'X9 A.B. COMMONM (W/ 2' DIA. WASHERS) 0 32' O.G. MAX. 1/2' CLGi. BOARD tRU55 24' O.C. NAIL CONT. RAT RUN TO INSULATION TRUS5 W/ (2) 12d m EA. TRUSS R-19 MIN. 1-05 REBAR CONT. 2X4 SPF RAT ADJACENT TO DIAGONAL BRACE. 0'-0" TO 30'-0" (I) 'X' BRACE 30'-1" TO 60'-0" (3) 'X' BRAGS 0 'X' BRACE a CENTER) (2 'XBRAGE DIVIDED EQUALY FROM GENTER TO END) eAL ENE) CO55 RC INS 1 FOR 2X4 SECURE TO 2X4 BLK W/2-12d SECURE T BLK W/ META-16 �2X4X4' SECURE TO TRUSS W/ 3-12d 6'-a' O.C. MAX TYP. AL 2x4 BLK SECURE THRU TRUSS 111/3-12de -'PER ENG'D TRUSS 24' O.G. MAX 1' - 0" 2 ' -OII EXTEN51ON OFT SERVICE [�)R. N.T.S. METAL LATH 1/16" 05B OR TEXTURED 1/2" PLYWOOD FINISH W/ I60 FELT 2X6 (GONT.) 2X4 (CONT.) SIMPSON EXPANSION HETA-I& CMU'S TEXTURED a FINISH TWO 5TOi,1' (2) 2X4 #2 ND 5YP DIAGONAIL BRACE— W1 2dEtv R 6ATTRUU$S�( DIAGONAIL BRACE TO 2X4 BLOCKING FIRST 2 BAYS (2) ImdNAILSEA FNp TO TRUSS 2X4 5YP STIFFBACK AT ALL UPRIGHTS OVER 4'-10" 1/16' 055 SHEATHING: USE ad NAILS AT 4' o.c. EDGE 4 6' c.c. FIELD IF SMA41immil 2X4 W/ 3/6" X 5 LAG OR SIMPSON HTC-4 a 32' O.C. MAX. SHEATHING NAILING TO BE I \\ 6"-9' OrC. IN FIELD 4' O.G.eALL EDGES Wad NAILS 1/16" 05k3 OR 1/2" PLYWOOD W/ 15 FELT 2X6 (CONT.) 2X FLOOR JOIST 2X4 (CONT.) 2" MIN. OVERLAP CAULK S IMP50N META-16 GMU'S TEXTURED FINISH TWO 5TORY FIRST FLOOR BLOGK SECOND FLOOR FRAMING M 15 FELT ON -1116' O_S$. 1/2' CLG. BOARD \ NAIL CONT. RAT RUN TO TRUSS W/ (2) 12d im EA. TRUSS TO DIAAGONNAL ADJACENT RAGS NT DSL TOP PLATE -2X4 STUD 16' O.G. MAX. 2X4 BTM. PLATE 5UB-FLOOR NAILED COMMOM TRUSS 24' 0.0. INSULATION R-19 MIN. HETA-16' FLR J5T TO BLK \—FLR TRUSS 1-+'S REBAR CONT. 0'-0" TO 30'-0" (U 'X' BRACE 30'-1" TO (o0'-0" (3) 'X' BRACE (I 'X' BRACE to CENTER) (2 'X' BRACE DIVIDED EQUAL.Y FROM CENTER TO ENE)) A LE ENID CR055 RAC INCT 2 - STORE BAKERS CROSSING LOT #137 PHASE #Or- MONOLITHIC BLOCK DETAILS & SECTIONS DATE: 6/30/03 SCALE: 1/41811-01 SHEET � 3 of ql- J A w 2 X 4 (MIN 2 X 3J I-3/16 TAPCON OR DRIVE PIN (MIN SHANK SIZE.145 MIN HEAD SIZE 300 2X4: MIN EMBEDMENT 1 1/4') SECURE TO BLOCK 8' FROM EACH END AND 18' W/3/16" TAPCONS OR DRIVE O.C. MAX. MIN 1-1/4' EMBEDMENT PIN (MIN SHANK SIZE.145 2 X 4 (MIN 2 X 3) 1-3/16 TAPCON MIN HEAD SIZE 300 OR DRIVE PIN (MIN SHANK SIZE.145 2 X 6 (MIN 2 X 3) 2-3/1(o TAPCON MIN EMBEDMENT 1 1/4') MIN HEAD SIZE 3IDID OR DRIVE PIN (MIN SHANK 51ZE.145 WITHIN 8' OF EACH END 4 MIN EMBEDMENT 1 1/4') MIN HEAD SIZE .300 15' O.C. MAX. SPACING. MIN EMBEDMENT i I/49 2 X 6: 8' FROM EACH END AND IS' PRECAST HEADER(MIN) 8' FROM EACH END AND IS' SECURE TO BLOCK O.G. MAX. MIN 1-1/4' EMBEDMENT O.C. MAX. MIN 1-1/4' EMBEDMENT W/2-3/16' TAPCONS OR DRIVE 2 X 6 (MIN 2 X 3) 2-3/16 TAPGON EXISTING BLK ABV. PIN (MIN SHANK SIZE.145 2 X 8 (MIN 2 X 3) 2-3/16 TAPGON MIN HEAD SIZE 300 OR DRIVE PIN (MIN SHANK SIZE.145 LESS THAN OR DRIVE PIN (MIN SHANK 51ZE.145 1/4' TEXTURED FIN15H MIN HEAD SIZE 300 l/8' TEXTURED FIN15H MIN EMBEDMENT I I/4') MIN EMBEDMENT 1 1/4') 16' HIEGHT. MIN HEAD 51ZE .300 WITHIN 8' OF EACH END 4 8' FROM EACH END AND 16' MIN EMBEDMENT 1 1/4') "I/16' OSB SHEATHING IS" O.C. MAX. SPACING. O.C. MAX. MIN 1-1/4" 1=MBEDMENT 8' FROM EACH END AND 18' 2 X 4 lro" O.G. MAX.(WHEN OVER 16' IN HIEGHT.) O.C. MAX. MIN 1-1/4" EMBEDMENT 2 X 4 (WHEN OVER 16" IN HIEGHT.) 2 X 8: 2 X 8 (MIN 2 X 3) 2-3/16 TAPCON 2 X SOLID BLK'G m ARCH SECURE t0 BLOCK---1/2' DRYWALL OR DRIVE PIN (MIN SHANK 51ZE.145 �/16' OSB SHEATHING 1/4' TEMPERED MA50NITE SECURE W/2-12d EACH END W/2-3/16' TAPCONS OR DRIVE 8' CMU .- 1"X4" OR 1'X2' P.T. NAILER MIN HEAD SIZE 300 GLUE 4 NAIL W/8d'S 8'-12' O.C. ATTACHMENT PER MANUFACTOR'S SPECS. PIN (MIN SHANK SIZE.145 2X4 BLOCKS MIN HEAD 51ZE 300 -- DOOR CASING MIN EMBEDMENT 1 1/4') MTL WDW FRAME 8' FROM EACH END AND I8' MIN EMBEDMENT 1 1/40) D.C. MAX. MIN 1- 1/4' EMBEDMENT CMU WALL WITHIN 8' OF EACH END 4 NOTE: #NOtE: NO GAP o WDW FRAME SHIM AS NEEDED 4 t0 EXCEED I/4' 18' O.G. MAX. SPACING. DOOR JAMB t0 PLUMB JAMB ATTACH TO 2 X DO NOT EXECEP 1/4". �C H � � � � T � 1 L j ` �'j� I 'j� I �- 11 � �� � � � � � � DETAIL TAjL C U T A � A � tDoopPER MANUFACTOR'S DETAILS. 2 X 4 (MIN 2 X 3) 1-3/16 TAPCON OR DRf VE PIN (MIN SHANK 51ZE.145 A PRECAST HEADER(MIN) MIN HEAD SIZE 300 MIN EMBEDMENT 1 1/49 J*NOTE- BL. TOP PLATE 8' FROM EACH END AND 18" 8' TEXTURED FIN15H O.C. MAX. MIN 1-1/4" EMBEDMENT MORE THAN SECURE 2 X RfP TO FIT 16" HIEGHT. 6' 058 SHEATHING IX4 P.T. OR 5/4' X 4' MIN. 2 X 6 (MIN 2 X 3) 2-3/16 TAPCON W/2-12dS 6'-8" O.C. MAX OR DRIVE PIN (MIN SHANK SIZE.145 X 4 16' O.C. MAX.(WHEN OVER 16' IN HIEGHT.) SECURE THUR FRAME AND EXTEND 1-1/4' INTO BLOCK MIN HEAP SIZE 300 X 4 (LUHEN OVER lro' IN HIEGHT.) W/3/ 6 TAPCONS OR DRIVE MIN EMBEDMENT 1 1/4'J PIN (MIN SHANK SIZE.145 X 80LIIp 13LK'G ARCH 8' FROM EACH ENID AND 18' MIN HEAD SIZE .3IDID ECURE W/2-126 EACH END I/2" DRYWALL O.C. MAX. MIN 1-1/4' EMBEDMENT 1/16' OSB SHEATHING MIN EMBEDMENT 1 1/4") I'X4' OR I'X2' P.T. NAILER 2 X 8 (MIN 2 X 3) 2-3/16 TAPCON 2 X 4 16' O.G. MAX.(WHEN OVER 16" IN HIEGHT.) ATTACHMENT PER MANUFACTOR'S 8PEC'S. REFER t0 MANUFACTURING OR DRIVE PIN (MIN SHANK 51ZE.145 MTL WDW FRAME DETAILS FOR SPACING. - DOOR CASING 2X4 BLOCKS NO GAP m WDW FRAMEMIN HEAP SIZE 300 NOTE: MIN EMBEDMENT 1 1/4') — GMU WALL EXCEED 1/4' SHIM AS NEEDED 8' FROM EACH END AND 18" 11 DOOR JAMB TO PLUMB JAMB O.C. MAX. MIN 1-1/4" EMBEDMENT A I� LU A� D E T A I� C U T A UJA� DO NOT EXEEED 1/4'. A C�UJA� D T74IL 1(o11 AND U(:E3 [DOCF-, JAME3 TC E5LCC< 3/4 o �/4. DBL. TOP PLATE B DBL. TOP PLATE DBL. TOP PLATE DBL. TOP PLATE 2X4 16" O.C. MAX. 2X4 16' D.C. MAX. SECURE 2X4 NN TO WOOD W/2-12d II O.G. STAGGERED SECURE 2X4 TO WOOD W/2 -12d g BT. PLATE O.C. STAGGERED Bt. PLATE SECURE 2X4 W/2-3/16' TAPCON5 OR DRIVE PIN (MIN SHANK SIZE.145 MIN HEAP SIZE 300 SECURE 2X4 W/2-3/16" TAPCONS MIN EMBEDMENT 1 1/4') OR DRIVE PIN (MIN SHANK SIZE.145 WITHIN 01 OF EACH END NOT TO MIN HEAD SIZE 300 EXCEED 18' O.CMAX. 2X4 50LID BLOCKING MIN EMBEDMENT 1 1/4') SECURE TO SHEATHING W/ WITHIN 8" OF EACH ENp NOT TO MIN. 2-12d PER BLK. EA. END 1/2' PLYWOOD EXCEED IS' O.CMAX. OR 71/16' O.S.B. 2X4 SOLID BLOCKING SECURE TO SHEATHING W/ 1/2' PLYWOOD MIN. 2-112d PER BLK. EA. ENp OR 7/16' O.S.B. EXTERIOfR Af.CkIUUA� W/LUfNDODU XT 1;Rf 0f;R AfRCHLUA� BAKERS _ __ ILOT #137 PHASE #2 MONOLITHIC BLOCK DETAILS NOTES DATE: 6/30/03 SCALE: I/41011-01 SHEET D4OF 4 m