699 Aero Ln 01-1693 PlansGENERAL NO I ES: FLORIDA S.B.C.,NFPA 101 1. HANDICAP ACCESS TO BUILDING IS DESIGNED AND FIELD BUILT BY OTHERS AND ` SUBJECT TO LOCAL JURISDICTION, 2. ALL DOORS SHALL BE OPEt1ABLc FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY, TOOL, SPECIAL KNOWLEDGE OR EFFORT. MANUALLY OPERATED FLUSH BOLTS OR SURFACE BOLTS SHALL NOT BE USED. 3. ALL GLAZING WITHIN A 24 INCH ARC OF DOORS, WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES ABOVE THE FLOOR, AND ALL GLAZING IN DOORS SHALL BE SAFETY, TEMPERED OR ACRYLIC PLASTIC SHEET. 4. FLOOR DESIGN LIVE LOAD -100 PSF CORRIDORS, LOBBY, 50 PSF ELSEWHERE 5. MAXIMUM WIND SPEED - 110 MPH 6. SEISMIC PERFORLIANCE CATAGORY-A 7. OCCUPANCY IS BUISNESS 8, OCCUPANT LOAD IS BASED ON 1 PERSON PER 100 SQUARE FEET OF FLOOR AREA, 9. ALL STEEL STRAPS REFERENCED ON FLOOR PLAN SHALL BE 1.5 INCH x 30 GA. WITH (7)- 16 GA. x 7/16 INCH CROWN x 1 INCH PENETRATION STAPLES EACH END OF STRAP (OR EQUIVALENT) FROM RIDGE BEAM TO COLUMN AND COLUMN -TO FLOOR, 10, PORTABLE FIRE EXTINGUISHER(S) PER N,F.P.A.-10 INSTALLED BY OTHERS ON ' SITE, AND SUBJECT -TO LOCAL JURISDICTION, 11. MINIMUM CORRIDOR WIDTH IS 44INCHES. 12. MINIMUM CORRIDOR FINISH IS CLASS A (GYPSUM), 'ELECTRICAL NOTES: NEC NFPA70 1. ALL CIRCUITS AND EQUIPMENT SHALL BE GROUNDED IN ACCORDANCE WITH THE APPROPRIATE ARTICLES OF THE NATIONAL ELECTRIC CODE (N.E.C.). 2. WHEN LIGHT FIXTURES ARE INSTALLED IN CLOSETS, THEY SHALL BE SURFACE MOUNTED OR RECESSED. INCANDESCENT FIXTURES SHALL HAVE COMPLETELY ENCLOSED LAMPS. SURFACE MOUNTED INCANDESCENT FIXTURES SHALL HAVE A MINIMUM CLEARANCE OF 12 INCHES AND ALL OTHER FIXTURES SHALL HAVE A MINIMUM CLEARANCE OF 6 INCHES FROM "STORAGE AREA" AS DEFINED BY N.E.C. 410--8(a), 3. VIHEN WATER HEATERS ARE INSTALLED THEY SHALL BE PROVIDED WITH READILY ACCESSIBLE DISCONNECTS ADJACENT TO THE WATER HEATER(S) SERVED. THE BRANCH CIRCUIT SWITCH OR CIRCUIT BREAKER SHALL BE PERMITTED TO SERVE AS THE DISCONNECTING MEANS ONLY WHERE THE SWITCH OR CIRCUIT BREAKER IS WITHIN SIGHT FROM THE WATER HEATER OR IS CAPABLE OF BEING LOCKED IN THE OPEN POSITION. 4. HVAC EQUIPMENT SHALL BE PROVIDED WITH READILY ACCESSIBLE DISCONNECTS ADJACENT TO THE EQUIPMENT SERVED, A UNIT SWITCH WITH A MARKED "OFF" POSITION THAT IS A PART QF THE HVAC EQUIPMENT AND DISCONNECTS ALL UNGROUNDED CONDUCTORS SHALL BE PERMITTED AS THE DISCONNECTING MEANS WHERE OTHER DISCONNECTING MEANS ARE ALSO PROVIDED BY A READILY ACCESSIBLE CIRCUIT BREAKER. 5. PRIOR TO ENIERGIZING THE ELECTRICAL SYSTEM THE INTERRUPTING RATING OF THE MAIN BREAKER MUST BE DESIGNED AND VERIFIED AS BEING IN COMPLIANCE WITH SECTION 110---9 OF THE N.E.C. BY LOCAL ELECTRICAL CONSULTANT. 6. -THE MAIN ELECTRICAL_ PANEL AND FEEDERS ARE DESIGNED BY OTHERS, SITE ` INSTALLED AND SUBJECT TO LOCAL JURISDICTION APPROVAL, 7. ALL CIRCUITS CROSSING OVER MODULE MATING LINE(S) SHALL BE SITE CONNECTED WITH APPROVED ACCESSIBLE JUNCTION BOXES OR CABLE CONNECTORS, 8. RECESSED PORTIONS OF LIGHTING FIXTURE ENCLOSURES,OTHER THAN AT THE POINTS OF SUPPORT, SHALL BE SPACED AT LEAST 1/2" FROM CUMBUSTIBLE MATERIALS. 9• THERMAL INSULATION SHALL NOT BE INSTALLED WITHIN 3" OF THE RECESSED FIXTURE ENCLOSURE, WIRING COMPARTMENT, OR BALLAST, AND SHALL NOT BE INSTALLED ABOVE THE FIXTURE SO AS TO TRAP HEAT AND PREVENT THE FREE CIRCULATION OF AIR, IvIECHAI' I AL NOTES: S,M.C, 1. ALL SUPPLY AIR REGISTERS SHALL BE 12 INCHES BY 12 INCHES ADJUSTABLE WITH 8 INCHES BY 16 INCHES (INSIDE) x 5/8 INCH OVERHEAD FIBERGLASS DUCT, UNLESS OTHERWISE SPECIFIED. DUCTS LOCATED IN VENTILATED ATTIC SHALL HAVE AN INSULATION VALUE OF R-6. DUCTS LOCATED IN UNCONDITIONED INTERIOR SPACES SHALL HAVE AN INSULATION VALUE OF R 4.2. 2. INTERIOR DOORS SHALL BE UNDERCUT 1.5 INCHES ABOVE FINISHED FLOOR FOR AIR RETURN. ANY ON -SITE ADJUSTMENTS OF DOORS AFTER SET-UP ARE NOT THE RESPONSIBILITY OF THE BUILDING MANUFACTURER. 3. VENT FANS SHALL BE DUCTED TO THE EXTERIOR AND TERMINATE AT AN APPROVED VENT CAP. 4. HVAC EQUIPMENT SHALL BE EQUIPPED WITH OUTSIDE FRESH AIR INTAKE PROVIDING 20 CFM FOR EACH OCCUPANT, OR 50 CFM FOR EACH WATER CLOSET OR URINAL_, WHICHEVER IS GREATER. 5. IN PRIVATE RESTROOMS CONTAINING ONE TOILET AND ONE LAVATORY, RESTROOM VENT FANS SHALL PROVIDE ONE CFM PER SQUARE FOOT OF FLOOR AREA. IN OTHER RESTROOMS FANS SHALL PROVIDE A MINIMUM OF TWO CFM PER SQUARE" FOOT OF RESTROOM SQUARE FOOT. 6. IN AN ( BATHROOPA THAT DOES NOT CONTAIN BATHTUBS, AND/OR SHOWERS, MECHANICAL EXHAUST MAY BE OMITTED WHEN NATURAL VENTILATION OR AN APPROVED RECIRCULATING AIR TREATMENT SYSTEM IS PROVIDED. PLUMBING NOTES: S.P.C. ` 1. CUSTOMER ASSUMES ALL RESPONSIBILITY FOR DRINKING WATER FACILITIES. 2. ALL PLUMBING FIXTURES SHALL HAVE SEPARATE SHUT-OFF" VALVES. 3. STORAGE -TYPE WATER HEATERS SHALL HAVE A SAFETY PAN WITH A 1-INCH DRAIN TO EXTERIOR, T&P RELIEF VALVE WITH A SEPARATE DRAIN TO EXTERIOR, AND A SHUT-OFF VALVE WITHIN 3 FEET ON COLD WATER SUPPLY LINE. 4. WATER SUPPLY LINES SHALL BE POLYBUTYLENE, CPVC, OR COPPER; WHEN POLYBUTYLENE SUPPLY LINES ARE INSTALLED, THE MAXIMUM WATER HEATER TEMPERATURE IS 180 DEGREES F. THE POLYBUTYLENE PIPE INSTALLER SHALL VERIFY THAT IT'S USE WILL BE RESTRICTED TO THE PRODUCT MANUFACTURER'S CONDITITIONS AND LIMITATIONS INCLUDING CHLORINE CONCENTRATION LEVELS. 5. WATER CLOSETS ARE TANK TYPE AND URINALS ARE FLUSH VALVE TYPE UNLESS OTHERWISE SPECIFIED. 6. DWV SYSTEM SHALL BE EITHER ABS OR PVC-DWV. 7. BUILDING DRAIN AND CLEANOUTS ARE DESIGNED AND SITE -INSTALLED BY OTHERS, SUBJECT TO LOCAL JURISDICTION APPROVAL. 8. TOILETS SHALL BE ELONGATED TYPE WITH NON -ABSORBENT OPEN FRONT SEATS. 9. RESTROOM WALLS SHALL BE COVERED WITH NON -ABSORBENT MATERIAL TO A MINIMUM HEIGHT OF 48" A.F.F. 10, HUT WATER SUPPLY TO A FIXTURE REQUIRING HOT WATER, SHALL BE INSTALLED ON LEFT SIDE OF FIXTURE. 11. WATER SERVICE PIPING SHALL BE NOT LESS THAN ONE INCH INSIDE DIAMETER FOR GALVANIZED FERROUS PIPING, OR 3/4" INSIDE NOMINAL DIAMETER FOR COPPER, OR APPROVED NON CORROSIVE PIPE OR TUBE. 12. SHO'WERS(WHEN PROVIDED) SHALL BE CONTROLLED BY AN APPROVED MIXING VALVE WITH A ` MAXIMUM WATER OUTLET TEMPERATURE OF 120 DEG, F. 13. LAVATORIES OF PUBLIC RESTROOMS SHALL BE EQUIPPED WITH OUTLET DEVICES WHICH LIMIT THE FLOW OF HOT WATER -TO A MAXIMUM OF 0.5 GPM„ OR BE EQUIPPED WITH SELF -CLOSING VALVES (NON HANDI-CAPPED ,APPLICATIONS ONLY). MAXIMUM WATER TEMPERATURE IS 110 DEG. HANDICAPPED ACCESSIBILITY: ADA / ANSI A117.1 / FACBC 1. THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SIGN SHALL BE DISPLAYED AT ALI_ ACCESSIBLE RESTROOM FACILITIES AND AT ACCESSIBLE BUILDING ENTRANCES UNLESS ALL ENTRANCES ARE ACCESSIBLE. INACCESSIBLE ENTRANCES SHALL HAVE DIRECTIONAL SIGNS INDICATING THE ROUTE TO THE NEAREST ACCESSIBLE ENTRANCE. 2. ACCESSIBLE DRINKING FOUNTAINS SHALL HAVE A SPOUT HEIGHT NO HIGHER THAN 36 INCHES ABOVE THE FLOOR AND EDGE OF THE BASIN NO HIGHER THAN 34 INCHES ABOVE THE FLOOR FOR INDIVIDUALS IN WHEELCHAIRS. ADDITIONALLY, DRINKING WATER PROVISIONS SHALL BE MADE FOR INDIVIDUALS WHO HAVE DIFFICULTY IN BENDING. 3. WHERE STORAGE FACILITIES SUCH AS CABINETS, SHELVES, CLOSETS AND DRAWERS ARE PROVIDED, AT LEAST ONE OF EACH -TYPE PROVIDED SHALL CONTAIN STORAGE SPACE COMPLYING WITH THE FOLLOWING: DOORS, ETC. TO SUCH SPACES SHALL BE ACCESSIBLE (ie. TOUCH LATCHES, U-SHAPED PULLS); SPACES SHALL BE WITHIN 15 INCHES MINIMUM AND 48 INCHES MAXIMUM OF THE FLOOR FOR FORWARD REACH OR 9 INCHES MINIMUM AND 54 INCHES MAXIMUM, OF THE FLOOR FOR SIDE REACH; CLOTHES RODS SHALL BE A MAXIMUM OF 54 INCHES ABOVE THE FLOOR (48 INCHES MAXIMUM WHEN DISTANCE FROM WHEELCHAIR TO ROD EXCEEDS 10 INCHES) 4. CONTROLS, DISPENSERS, RECEPTACLES, AND OTHER OPERABLE EQUIPMENT SHALL BE NO HIGHER THAN 45 INCHES ABOVE THE FLOOR FOR FRONT APPROACH OR 54 INCHES ABOVE THE FLOOR FOR SIDE APPROACH, RECEPTACLES ON WALLS SHALL BE MOUNTED NO LESS THAN 15 INCHES ABOVE THE FLOOR. EXCEPTION: HEIGHT LIMITATIONS DO NOT APPLY WHERE THE USE OF SPECIAL EQUIPMENT DICTATES OTHERWISE OR WHERE ELECTRICAL RECEPTACLES ARE NOT NORMALLY INTENDED FOR USE BY BUILDING OCCUPANTS. 5. WHERE EMERGENCY WARNING SYSTEMS ARE PROVIDED, THEY SHALL INCLUDE BOTH AUDIBLE AND VISUAL ALARMS. THE VISUAL ALARMS SHALL BE LOCATED THROUGHOUT, INCLUDING RESTROOMS, AND PLACED 80 INCHES ABOVE THE FLOOR OR 6 INCHES BELOW CEILING, WHICHEVER IS LOWER. 6. DOORS TO ALL ACCESSIBLE SPACES SHALL HAVE ACCESSIBLE HARDWARE (ie. LEVER - OPERATED, PUSH -TYPE, U--SHAPED) MOUNTED NO HIGHER THAN 48 INCHES ABOVE THE FLOOR. 7. _ FLOOR SURFACES SHALL BE STABLE, FIRM, AND SLIP -RESISTANT. CHANGES IN LEVEL BETWEEN 0.25 INCH AND 0.5 INCH SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1:2. CHANGES IN LEVEL GREATER THAN 0.5 INCH REQUIRE RAMPS. CARPET PILE THICKNESS SHALL BE 0.5 INCH MAXIMUM. GRATINGS IN FLOOR SHALL HAVE SPACES NO GREATER THAN 0.5 INCH WIDE IN ONE DIRECTION. DOORWAY THRESHOLDS SHALL NOT EXCEED 0.5 INCH IN HEIGHT. 8. AL DOORS SHALL BE OPENABLE BY A SINGLE EFFORT. THE MAXIMUM FORCE REQUIRED TO OPEN A DOOR SHALL NOT EXCEED 8.5 LBS, FOR EXTERIOR SWINGING DOORS AND 5 LBS. FOR ALL SLIDING, FOLDING, AND INTERIOR SWINGING DOORS. 9. ACCESSIBLE WATER CLOSETS SHALL BE 19 INCHES FROM THE FLOOR TO THE TOP OF THE SEAT. GRAB BARS SHALL BE 36 INCHES LONG MINIMUM WHEN LOCATED BEHIND WATER CLOSET AND 42 INCHES LONG MINIMUM WHEN LOCATED ALONG SIDE OF WATER CLOSET, AND SHALL BE MOUNTED AT 33 INCHES FROM THE FLOOR TO THE TOP OF THE RAIL WITH 0.5 INCH MAXIMUM VARIATION. 10. ACCESSIBLE URINALS SHALL BE STALL -TYPE OR WALL -HUNG WITH ELONGATED RIMS AT A MAXIMUM OF 17 INCHES ABOVE THE FLOOR. 11. ACCESSIBLE LAVATORIES SHALL BE MOUNTED WITH THE RIM NO HIGHER THAN 34 INCHES ABOVE THE FLOOR AND A CLEARANCE OF AT LEAST 29 INCHES ABOVE THE FLOOR TO THE BOTTOM OF THE APRON. 12, ACCESSIBLE SINKS SHALL BE MOUNTED WITH THE RIM NO HIGHER -THAN 34 INCHES ABOVE THE FLOOR AND A CLEARANCE OF AT LEAST 27 INCHES HIGH, 30 INCHES WIDE, AND 19 INCHES DEEP UNDERNEATH SINK. THE SINK DEPTH SHALL BE 6.5 INCHES MAXIMUM. 13. HOT WATER AND DRAIN PIPES UNDER ACCESSIBLE LAVATORIES AND SINKS SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST CONTACT. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER ACCESSIBLE LAVATORIES AND SINKS. 14. ACCESSIBLE LAVATORIES AND SINKS SHALL HAVE ACCESSIBLE FAUCETS OPERABLE WITH ONE HAND AND REQUIRING LESS THAN 5 LBS. OF FORCE TO ACTIVATE (ie LEVER -OPERA -FED, PUSH -TYPE, ELECTRONICALLY CONTROLLED). SEPARATE LAVATORIES FOR PHISICALLY HANDI-CAPPED PERSONS SHALL NOT BE EQUIPPED WITH SELF CLOSING VALVES. 15, WHERE MIRRORS ARE PROVIDED IN RESTROOMS, AT LEAST ONE SHALL BE PROVIDED WITH ITS BOTTOM EDGE NO HIGHER THAN 40 INCHES ABOVE THE FLOOR. 16, WHERE MEDICINE CABINETS ARE PROVIDED, AT LEAST ONE SHALL BE LOCATED WITH A USABLE SHELF NO HIGHER THAN 44 INCHES ABOVE THE FLOOR. 17. GRAB BARS REQUIRED FOR ACCESSIBILITY SHALL BE 1.5 INCHES IN DIAMETER WITH 1.5 INCHES OF CLEAR SPACE BETWEEN -THE BAR AND THE WALL. 18, TOILET STALL_ DOORS SHALL BE THE SELF ---CLOSING -TYPE. 19. A TOWEL DISPENSER SHALL BE LOCATED ADJACENT TO ALL ACCESSIBLE LAVATORIES. SITE -INSTALLED ITEMS: NOTE THAT THIS LIST DOES NOT NECESSARILY LIMIT THE ITEMS OF WORK AND MATERIALS THAT MAY BE REQUIRED FOR A COMPLETE INSTALLATION. ALL SITE RELATED ITEMS ARE SUBJECT TO LOCAL JURISDICTION APPROVAL. 1. THE COMPLETE FOUNDATION SUPPORT AND TIE DOWN SYSTEM. 2. RAMPS, STAIRS, AND GENERAL ACCESS TO THE BUILDING. 3. PORTABLE FIRE EXTINGUISHER(S). 4. DRINKING WATER APPARATUS (WHEN NOT SHOWN ON PLAN), BUILDING DRAINS, CLEANOUTS, AND CONNECTION TO THE PLUMBING SYSTEM, 5. ELECTRICAL SERVICE CONNECTION (INCLUDING FEEDERS) TO THE BUILDING. 6, THE MAIN ELECTRICAL PANEL AND SUB -FEEDERS (MULTI -UNITS ONLY). 7. CONNECTION OF ELECTRICAL_ CIRCUITS CROSSING OVER MODULE PLATING LINE(S) (MULTI -UNITS ONLY). 8, STRUCTURAL AND AESTHETIC INTERCONNECTIONS BETWEEN MODULES (MULTI -UNITS ONLY). 9. REQUIRED PLUMBING FACILITIES NOT PROVIDED IN THE MODULAR BUILDING ARE TO BE LOCATED IN ADJACENT BUILDING(S). SEE ATTATCHED LETTER. 10, DRAINAGE PIPING BELOW FLOOR JOIST LEVEL 11, FIRE ALARM SYSTEM (IF APPLICABLE) 12. SPRINKLER SYSTEM (INSTALLED BY A LICENCED INSTALLER) INTERIOR FINISH 1997 BCC SEC. 4-09,2.9 &. CHAPTER 8 ALL CORRIDORS AND CEILING FINISH ARE CLASS "A" GYPSUM WITH FLAME SPREAD 0-25, ANDSMOKE DEVELOPED 0-450 ALL INTERIOR WALL FINISH IS CLASS "C" PANELING WITH FLAME SPREAD 76-200, ANDSMOKE DEVELOPED 0-450 CARPET HAS A CRITICAL RADIENT FLUX OF 0.22 WATTS/SCE. CM AS TESTED IN ACCORDANCE WITH NFiPA 253 s i . r i • r i s de' 9 ���.� ��• 4;$� CFIECKED . CC� /0� PLAN NO-�Q _8 25 _- - DATE -- � / T 1 ----- 51100 APPROVED BY F ICHARD BULLOCK SHT. #1 SHT. #2 A'�OU1 MODULAR BUILDING PLANS EXAMINER SHT. #3 FLORIDA CERTIFICATE NUMBER SMP-0000003 LISTING AGENCY APPROVAL THESE PRINTS COMPLY WITH THE FLORIDA. MANUFACTURED BUILDING ACT OF 1979 CONSTRUCTION CODES AND ADHERE TO THE FOLLOWING CRITERIA: CONST. TYPE VI OCCUPANCY B ALLOWABLE ¢r OF FLOORS 1 WIND VELOCITY 110 FIRE RATING OF EXTERIOR WALLS 0 PLAN NO. GS832S ALLOWABLE FLOOR LOAD 50100 _ APPROVAL DATE 05/041/00 _ MANUFACTURER PER DCA LETTER , .D.S. 1 t� T 'Space 1 1 11 N A ® U JJ� Z _111k K 3637 4TH STREET NORTH r , y , SAINT PETERSBURG, FLORIDA 33704 A � Cl ;� �� , � LICENSE #AR-0005065 M . D.`J S. 2730 12TH STREET SOUTH SAINT PETERSRURG, FLORIDA 33705 LISTING AGENCY PHONE #727-898-6004 DATE SCALE QUOTE SER. NO. 05/04/00 1 -NTS- GS832S 1 n SIZE CODE TYPE USE CHECKED BY REV. APPF2dVD # PACE PER PRINT 1997 SBCC VI B MDS GS�3�3//2S '1 OF 4 s - r i , -r _ 28'-0" _ 10'-0" 6' 8" 11'-4" 11'-4" 21'-4 3/�11 3'-4 3/4„ 3 I GFI UNDER I �F� J FLOOR 1 1 TON H`JAC INSTALLED PER �\ A/V __� 42° PANEL ' MFG'R. SPEC, W/3.5 KW HEAT -- 25'-4" 21'-4"`. t , 36x60" PLAN TA LE 2' 8' STRIP 420 CFM @ .5 IWC ESP WITH STORAGE 23'- _ STRIP 4'-8' \\ w z 24x80 r— --i jo I GFI 6'-8" T I ` 8-0., FI E FILE �� o =-� , a xo ror f v 12 - - - j Cr Cy S x / -w—_— `- - - ­ \\ r� \ 2 -6 5/8„ STRIP �� V) I 10'-�J„ - _ afO 24x80 SHELF AT — CKT # 1A & 2A SHELF AT `69" <� PLAN RACK - 69" AFF 12" X 20" R/A GRILLE THRU WALL CC5Y ,18'-8 3/4"6 —8 3/4" 2'-8 3/4" s 22'-8 3/4" PHONE JACK AND RECEPTS ABOVE DESKS TO BE AT 34" 4'-0„ L.E. CAPI tAi- MOUNT DECAL 3" BELOW CAP TRIM F-01 4'-0" G.E. CAPITAL1I MOUNT DECAL 3" BELO TOP OF A/C UNIT UNIT I.D. PLACEMENT HIGH PRESSURE SEAMLESS COUNTERTOP \ MOULDINGS PER SPECS uvCu PRESSURE LAMINATE CGUNTERTG'P s,=e,:;: n_., c' a 'dO❑➢GRAIN PANELING ON IX3 CONTINUOUS FRONT PLATE !!_E t➢INET TO ➢ SIDES FlN➢ FRONT, TYP. Sx3 ALONG PERIMETER & AT 2'-D' O.C. ­A-EG dITH PX3 GRADE SPF --✓ PLASTIC MOULDINGS, TYP. COUNTER TOP DETAIL HIGH PRESSURE LAMINATE PER SPECS - - 36' DEEP X LENGTH 36' DEEP HIGH PRESSURE LAMINATE TOP PLASTIC MOULDING 10, TOP EXTENDS 1' PAST OPEN END (TYP.) 33' HIGH FACE TYP 1X3-"` HIGH PRESSURE LAMINATE i I a `.=..-� HIGH PRESSURE LAMINATE 7 UDE WALL COVERMGS S�ONS DO NOT MCt_ DIM NOTE-. EN BUILDING CRITERIA THESE PRINTS COMPLY WITH THE FLORIDA MANUFACTURED BUILDING ACT OF 1979 CONSTRUCTION CODES AND ADHERE TO THE FOLLOWING CRITERIA; CONST, TYPE VI OCCUPANCY B - ALLOWABLE # OF FLOORS 1 WIND VELOCITY 11.0 _ - FIRE RATING OF EXTERIOR `.HALLS 0 _ PLAN NO, GS832S ALLOWABLE FLOOR LOAD 50 10() _ APPROVAL DATE 05/04/00 SYMBOLS: DUPLEX RECEPT @ 16" AFF DUPLEX RECEPT @ 42" AFF RECEPT 220 VOLTAAFF FLOOR RECEPTACLE SWI TCH 33 WAY SWITCH PHONE JACK @ 42"Q PHONE JACK @ 16" FLOOR PHONE JACK O THERMOSTAT INCANDESCENT LIGHT 60W, MAX, W P WATER PROOF PORCH LIGHT 60W. MAX. -6- W/PHOTO CELL � FLUORESCENT FIXTURE 87.6 W. MAX. RECESSED FLUORESCENT 87.6 W. MAX. u JUNCTION BOX — _— V JUNCTION BOX -- 100 CFM EXHAUST FAN Ej EXHAUST FAN WITH LIGHT — EMERGENCY LIGHT J BOX FOR MANUAL PULL STATION & BELL J❑P J BOX FOR MANUAL PULL STATION m 12"x12" SUPPLY AIR REGISTER 12"x12" RETURN AIR GRILLE 1 HOUR FIRE RATED WALL OVER THE WALL RETURN AIR JUMP 8x16 FIBERGLASS DUCT & 12x12 GRILLES PANEL "A" KVA GENERAL LIGHTING .0035 KW SF x 224 SF x 1.25 .98 7 RECEPTS @ 180 VA/1000 1.26 WATER HEATER 1.9 x 1,25 .38 _ 1 FANS @ .3 KW x 1.25 HVAC 4.4 — OTHER _ - OTHER - TOTAL 7.02-_--------- TOTAL/240x1000 29.3 INSTALL 100 AMP PANEL 120/240V 10 — ELECTRIC SCHEDULE CIRCUIT # NOMENCLATURE BREAKER (AMPS) WIRE SIZ CU. NM. `Ai/G 1 & 2 HVAC___ SIZED PER MFR. SPECS. _ 3A WATER HEATER 30A 1P 10--2 4-7 LIGHTS RECEPTS 20A 1P 12-2 ALL PORTABLE APPLIANCES, INCLUDING W/H, TO HAVE DISCONNECT IF NOT WITHIN VIE.^! OF ELECtRIC PANEL. LISTED TRUSSES @ 16" Q.C. MAX. ROOF COVERING OVER 3/8" PLYWOOD LISTED ROOF TRUSS DESIGN LOADS: RATEDED SHEATHING, MINIMUM EXP-1 20/0 LIVE LOAD 20 PFS TOP CHORD OR OPTIONAL 7/16" ORIENATED STRAND DEAD LOAD 6 PSF TOP CHORD BOARD, EXP. 1, 24/16. SEE ROOF DEAD LOAD 4 PSF BOTTOM CHORD SHEATHING DETAIL. ZT04 --- 12 1/2" RIM MEMBER 2x4 SPF #3 MIN. 30 GA. x 1-1/2" STEEL STRAP FROM TRUSS TO WALL STUD Q 16" O.C. WITH 7-16 GA. X 1" STAPLES PER STRAP END. (TYPICAL SIDEWALLS) INSTALL DOUBLE STRAPPING AT EACH STUD FOR FIRST 4' IN FROM EACH CORNER, 2x4 SPF #2 WALL STUDS 016" O.C. �S WINDOW HEADER, SEE SPAN CHART FOR SPECS TYP. WINDOW, SEE -� SHEET #2 FOR SPECS WALL INTERIOR FINISH, SEE SHEET #2 FOR SPECS TYP. WINDOW SILL 96" WALL HEIGHT R-11 KRAFTBACK WALL INSULATION -� 2x4SPF #2 BOTTOM PLATE R- 7 UNFACED �p FLOOR INSULATION - 30 GA. x 1--1/2" STEEL STRAP FROM WALL STUD TO FLOOR JOIST AT OPENING STUDS AND 16" O.C. WITH 7- 16 GA. x 1" STAPLES PER STRAP END. (TYPICAL SIDEWALLS & ENDWALLS) INSTALL DOUBLE STRAPPING AT EACH STUD FOR FIRST 4' IN FROM EACH CORNER. INSTALL (2) 3/8"X3" LAG SCREWS FROM TOP FLANGE OF OUTRIGGER INTO FLOOR, AND/OR RIM JOIST ABOVE (TYP. EACH OUTRIGGER) OUTRIGGER AND CROSSMEMBER SPACING 48" O.C. MAX. INERTIOR FINISH MATERIAL SEE SPEC. SHEET # 1 FOR INTERIOR FINISH MATERIAL 6 SQUARE FEET NET FREE AREA OF ATTIC VENTILATION TO BE PROVIDED BY ROOF AND/OR GABLE VENTS. SEE SPEC. SHEET #2 FOR J SEE SHEET #2 FOR DUCT SPECIFICATIONS. ROOF INSULATION SEE SHEET #2 FOR CEILING INT, FINISH 1 C SEE SHEET #2 FOR FLOOR DECKING AND FLOOR COVERING SPECS 48" TYPICAL , 2x SPF #2 FLOOR JOISTS, SEE VT&G SHEET #2 FOR SIZE & SPACING JOINT (TYPICAL) r f GENERAL CROSS SECTION MOTES 1. UNLESS OTHERWISE SPECIFIED, ALL STEEL MUST COMPLY WITH ASTM A36, YIELD STRENGTH = 36 KSi, AND COMPLY WITH RISC 2. ALL LAG SCREWS MUST COMPLY WITH ASTM A307. 3. SEE FOUNDATION PLAN FOR PIER AND TIE DOWN STRAPPING LOCATIONS, ORIENTATIONS, AND SPECIFICATIONS. DESIGN CRITERIA SBCC FLOOR LOAD 50 PSF LL FLOOR LOAD 10 PSF DL WIND LOAD 110 MPH ROOF: 20 PSF LL ROOF 10 PSF DL ZT11 P 2/12" MIN, OPTIONAL TRUSS WITH SHINGLE ROOF EXTERIOR MALL FINISH: .019 ALUM. EXTERIOR WALL STRUCTURAL BRACING SIDEWALLS: BRACING INSTALLATION: STRUCTURAL SHEATHING SHALL CONSIST OF A 4' MINIMUM WIDTH SHEET EXTENDING CONTINUOUSLY FROM TOP TO BOTTOM PLATE WITH ALL SHEATHING EDGES EXTENDING 3/4" MINIMUM OVER 2" NOMINAL LUMBER OF THE SAME SIZE AND GRADE AS EXTERIOR WALL FRAMING. BRACING SHALL BE LOCATED AS CLOSE TO EACH CORNER OF BUILDING AS POSSIBLE. BRACING MATERIAL: 1/8" STRUCTURAL RED THERMO-PLY FASTENED WITH 16 GA. X 1" X 1-1/4" STAPLES 3" O.C. ON EDGES AND 6" O.C. IN THE FIELD, ENDWALLS: BRACING INSTALLATION: STRUCTURAL SHEATHING SHALL EXTEND CONTINUOUS FROM TOP OF TRUSS TOP CHORD TO 3/4" MINIMUM BELOW TOP OF RIM JOIST WITH ALL SHEATHING EDGES SUPPORTED BY 2" NOMINAL LUMBER OF THE GRADE AS EXTERIOR WALL FRAMING. BRACING MATERIAL: 3/8" CDX PLYWOOD EXP-1 24/0 FASTENED WITH 7/16" X 1 1/2" X 16 GA. STAPLES 3" O.C. EDGES, 6" O.C. FIELD. HEADER 2-2x4 SPF #2 (IF HEADER IS WITHIN 3' OF ENDWALL USE 2-2x6 SPF #2) 36x80 DOOR FRAMING WINDOW FRAMING D �- 2„ I -� �-1 1 /4" CROSSMEMBER SECTION FIRST 13'-4" IN FROM EACH ENDWALL SHALL HAVE ROOF SHEATHING BLOCKED BY 2x SPF #2 LUMBER & FASTENED TO TRUSSES 2 1/2" O.C. ALONG PERIMETER OF UNIT, 4" O.C. ALL OTHER PANEL EDGES, 6" O.C. FIELD. HEADERS 2-2x4 SPF ,#2 (IF HEADER IS WITHIN 3' OF ENDWALL USE 2-2x6 SPF #2) PLATE SPF #2 'LE STUDS >PF #2 3" O.C. LISTING AGENCY APPROVAL THESE PRINTS COMPLY WITH THE FLORIDA MANUFACTURED BUILDING ACT OF 1979 CONSTRUCTION CODES AND ADHERE TO THE FOLLOWING CRITERIA: CONST. TYPE VI OCCUPANCY ^o---- _ ALLOWABLE # - OF FLOORS 1 WIND VELOCITY 110 FIRE RATING OF EXTERIOR WAI LS 0 PLAN NO. GS832S ALLOWABLE FLOOR LOAD 50/100_^ APPROVAL DATE 05/04/60 MANUFACTURER PER DCA LETTER FULL LENGTH 3/16" FILLET WELDS ONE SIDE OF ALL FLANGES AND WEBS AT ALL OUTRIGGERS AND CROSSMEMBERS. 1-1 /2" 12 GA. OUTTRIGGER `- 12 GA. CROSSMEMBER. (TO BE LOCATED OPPOSITE 1-1/2" OUTRIGGER AS SHOWN) OUTRIGGER SECTION FRAME DETAIL_ J �C �J 0 V) STAGGER JOINTS 48" O.C. ENDWALL 1/2" RATED SHEATHING, PLYWOOD TO BE FASTENED TO TRUSSES WITH N--17 STAPLES OR EQUIV. (7/16" CROWN X 1 1/2" LEG X 16 GAUGE) ROOF SHEATHING DETAIL h� xlk ' Y d _ t �J 6uipool. -lua",Gjd o uolslnl suol.Jonala pgns �o •1dop 6uraaau+6ua Aq paAo,add-' suol}r✓nala aplAoad jo suol��nala Cl ' aool� pagslul� ao� sdpoo �t.ro oaw .jsnyV INIJ, ACC'-, SlEAfFY _._ S' _.�_�._ _._...._. f �l Iryr;�tj. ✓ { 1997 e oi. Ff '1 r SANFORD BUILDING DEPT. THESE PLANS ARE REVIEWED AND CONDITIONALLY ACCEPTED FOR PERMIT. A PERMIT ISSUED SHALL BE CONSTRUED TO BE A LICENSE TO PROCEED WITH THE WORK AND NOT AS AUTHORITY TO VIOLATE, CANCEL. ALTER, OR SET ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT Tr}E BUILDING DEPT FROM THEREAFTER REQUIRING A CORREC- TION OF ERRORS ON THE FLANS, CONSTRUCTION OR OTHER VIOLATICNS OF THE CODES PLANISS w`S .e,f -. 1 CITY OF SAN'r'ORD NA,L IMProyin REQUIRED