H.V.A.C. SPECIFICATIONS
GENERAL
SCOPE OF WORK
FURNISH AND INSTALL COMPLETE AIR CONDITIONING SYSTEMS AS INDICATED ON THE DESIGN
DRAWINGS AND AS OUTLINED WITHIN THESE SPECIFICATIONS. WORK SHALL INCLUDE BUT NOT BE
LIMITED TO THE FABRICATION AND/OR INSTALLATION OF THE SCHEDULED AIR CONDITIONING UNITS,
EXHAUST FANS, AIR DISTRIBUTION AND DUCTWORK.
RELATED WORK SPECIFIED ELSEWHERE
REFER TO ELECTRICAL SPECIFICATIONS FOR ALL ELECTRICAL WORK PERFORMED IN CONJUNCTION
WITH MECHANICAL WORK. DIVISION 15 CONTRACTOR SHALL BE HELD RESPONSIBLE FOR ALL CONDUIT,
WIRING, JUNCTION BOXES, ETC. REQUIRED FOR COMPLETE, WORKING HVAC CONTROLS AND
EQUIPMENT.
CODES AND STANDARDS
ALL MECHANICAL WORK SHALL BE GOVERNED AND INSTALLED IN ACCORDANCE WITH THE APPLICABLE
PROVISIONS OF THE FLORIDA BUILDING CODE, NATIONAL ELECTRIC CODE, FLORIDA MECHANICAL
CODE, FLORIDA FIRE PREVENTION CODE, FLORIDA LIFE SAFETY CODE, AMERICANS WITH DISABILITIES
ACT, ASHRAE STANDARDS, ANSI, SMACNA, AND FLORIDA ENERGY EFFICIENCY CODE. NO WORK SHALL
BE COVERED OR CONCEALED UNTIL PROPERLY INSPECTED AND TESTED.
PRODUCTS
ALL EQUIPMENT AND APPURTENANCES SHALL BE NEW UNLESS OTHERWISE NOTED.
SUBSTITUTIONS
EQUIPMENT AND DESIGN OF SYSTEMS AS INDICATED ON THE DRAWINGS AND WITHIN THESE
SPECIFICATIONS SHALL BE CONSIDERED AS THE SPECIFIED STANDARD OF QUALITY. NO
SUBSTITUTIONS SHALL BE MADE WITHOUT PRIOR WRITTEN APPROVAL OF THE ENGINEER.
ILL•] T' X"01 <F"powl
ALL MATERIALS SHALL BE FABRICATED AND INSTALLED IN A NEAT, WORKMANLIKE MANNER. THE
CONTRACTOR SHALL COORDINATE WITH ALL TRADES TO AVOID CONFLICTS AND DELAYS. NO
ALLOWANCES WILL BE MADE FOR REWORK DUE TO COORDINATION CONFLICTS WITH OTHER TRADES.
NO WORK SHALL BE COVERED OR CONCEALED UNTIL PROPERLY INSPECTED AND TESTED.
MAINTENANCE MANUALS
THE CONTRACTOR SHALL PROVIDE COMPLETE MAINTENANCE MANUALS AND OPERATING
INSTRUCTIONS PER DIVISION 1 REQUIREMENTS INCLUDING: OPERATING AND MAINTENANCE
INSTRUCTIONS, SPARE PARTS LIST, COPIES OF WARRANTIES, WIRING DIAGRAMS, INSPECTION REPORTS
& APPROVALS, SHOP DRAWINGS AND PRODUCT DATA.
TESTING
ADJUST THE AIR CONDITIONING SYSTEMS, VENTILATING SYSTEMS, FANS, ETC., TO DELIVER NOT LESS
THAN THE REQUIRED AIR QUANTITY WITH QUANTITIES IN EXCESS TO BE SUBJECT TO THE APPROVAL OF
THE ENGINEER IF FOUND TO NOT HAVE OBJECTIONABLE EFFECTS SUCH AS NOISE, DRAFTS, OR MOTOR
OVERLOAD. DIV. 15 CONTRACTOR SHALL PROVIDE THREE (3) COPIES OF A TEST AND BALANCE REPORT
TO THE ENGINEER AT TIME OF SUBSTANTIAL COMPLETION INSPECTION. THE TEST AND BALANCE
REPORT SHALL BE PREPARED BY A CONTRACTOR CERTIFIED BY ASSOCIATED AIR BALANCE COUNCIL
OR NATIONAL ENVIRONMENTAL BALANCING BUREAU.
WARRANTY/GUARANTEE:
THE CONTRACTOR SHALL WARRANTY/GUARANTEE AND MAINTAIN THE STABILITY OF WORK AND
MATERIALS AND KEEP SAME IN PERFECT REPAIR AND CONDITION OF THE PERIOD OF ONE (1) YEAR.
DEFECTS OF ANY KIND DUE TO FAULTY WORK OR MATERIALS APPEARING DURING THE ABOVE
MENTIONED PERIOD MUST BE IMMEDIATELY MADE GOOD BY THE CONTRACTOR AT HIS OWN EXPENSE
TO THE ENTIRE SATISFACTION OF THE OWNER AND ARCHITECT AND ENGINEER. SUCH
RECONSTRUCTION AND REPAIRS SHALL INCLUDE ALL DAMAGE TO THE FINISH OR FURNISHING OF THE
BUILDING RESULTING FROM THE ORIGINAL DEFECT OR REPAIRS THERETO.
EXECUTION
DRAWINGS ARE GENERALLY DIAGRAMMATIC AND DO NOT NECESSARILY SHOW EVERY FITTING AND
DETAIL. INSTALL DUCTS, EQUIPMENT AND CONTROLS IN A NEAT WORKMANLIKE MANNER AND IN
ACCORDANCE WITH GOOD PRACTICE FOR A COMPLETE, WORKABLE INSTALLATION. AVOID CONFLICT
WITH OTHER TRADES; MAKE ADEQUATE PROVISIONS FOR PREVENTING NOISE AND VIBRATION.
ARRANGE EQUIPMENT IN THE AVAILABLE SPACE TO MAKE ALL WORKING PARTS ACCESSIBLE FOR
MAINTENANCE AND SERVICE. CONTRACTOR IS RESPONSIBLE FOR ALL FIELD MEASUREMENTS
REQUIRED TO PROVIDE AN APPROVED, FUNCTIONAL INSTALLATION. IT IS TO BE UNDERSTOOD THAT
UNFORESEEN CONDITIONS MAY EXIST AND WORK MAY NOT BE LOCATED OR INSTALLED EXACTLY AS
INDICATED ON THE DRAWINGS. DEVIATIONS REQUIRED TO COORDINATE WITH OTHER TRADES SHALL BE
CONSIDERED PART OF THIS CONTRACT. NO WORK SHALL BE COVERED OR CONCEALED UNTIL
PROPERLY INSPECTED AND TESTED.
EQUIPMENT:
AIR CONDITIONING UNITS:
UNITS SHALL BE SPLIT SYSTEM, AIR-TO-AIR, ELECTRIC AIR CONDITIONING UNITS AS SCHEDULED ON THE
DESIGN DRAWINGS. UNITS SHALL HAVE SINGLE POINT POWER CONNECTIONS. TOTAL COOLING
CAPACITY OF THE UNITS SHALL BE AS SCHEDULED ON DRAWINGS. UNIT CABINET SHALL BE
CONSTRUCTED OF GALVANIZED STEEL AND COATED WITH BAKED ENAMEL. CABINET INSULATION SHALL
COMPLY WITH FLORIDA ENERGY CODE. REFRIGERATION SYSTEM - THE UNITS SHALL HAVE SERVICE
VALVES AND VIBRATION ISOLATION AS INDICATED ON INSTALLATION DETAILS.
FANS AND MOTORS - THE INDOOR AIR FANS SHALL BE OF THE FORWARD -CURVED CENTRIFUGAL CLASS 1
TYPE. THE OUTDOOR AIR FANS SHALL BE OF THE PROPELLER TYPE, EACH DIRECTLY DRIVEN BY AN
INHERENTLY PROTECTED MOTOR. MOTOR AND DRIVE TO PROVIDE HIGHER FAN OUTPUT WHEN JOB
REQUIREMENTS EXCEED STANDARD FAN CAPACITY SHALL BE PROVIDED.
SAFETY CONTROLS - COOLING SYSTEM SHALL BE PROTECTED BY: LOSS OF CHARGE PROTECTION, HIGH
AND LOW PRESSURE, COMPRESSOR MOTOR OVERLOADS, AND A TIMING DEVICE WHICH WILL PROHIBIT
THE COMPRESSOR MOTOR FROM BEING SUBJECTED TO A STARTING CURRENT MORE THAN ONCE
EVERY FIVE MINUTES. THREE PHASE UNITS SHALL HAVE PHASE -LOSS PROTECTION.
CONTROLS - PROVIDE WALL MOUNTED, HEAT/COOL ON -OFF -AUTO THERMOSTAT FOR EACH UNIT. MOUNT
THERMOSTATS AT 48" ABOVE FINISHED FLOOR.
UNITS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S SPECIFICATION AND
SERVICE REQUIREMENTS. AIR HANDLERS SHALL BE INSTALLED WITH SUFFICIENT CLEARANCE ON ONE
SIDE TO ALLOW SAFE REMOVAL OF ALL FILTERS. ACCESS SHALL BE PROVIDED AT FRONT OR SIDE OF
UNIT FOR REMOVAL OF BLOWER AND HOUSING.
WARRANTY:
PROVIDE A ONE (1) YEAR WARRANTY ON THE COMPLETE SYSTEM AND AN ADDITIONAL FOUR (4) YEAR
FACTORY WARRANTY ON ALL COMPRESSORS. LOSS OF REFRIGERANT WILL BE REPLACED AT NO COST
TO OWNER FOR A PERIOD OF ONE (1) YEAR.
PIPING:
CONDENSATE DRAINS:
CONDENSATE PIPE TO BE PVC. ROUTE TO BUILDING EXTERIOR AS INDICATED ON PLANS. HVAC
CONTRACTOR TO PROVIDE P-TRAP AT UNIT SIZED FOR 2" GREATER THAN UNIT STATIC PRESSURE.
INSULATE CONDENSATE PIPE WITH 1/2" ARMAFLEX OR EQUAL INSULATION. CONDENSATE DRAIN LINE
SHALL BE NOT LESS THAN THE EQUIPMENT DRAIN LINE SIZE AND, IN NO CASE LESS THAN 3/4" DIAMETER.
REFRIGERANT PIPING:
COVER ALL EXPOSED LIQUID LINES AND ALL SUCTION PIPING (INDOORS AND OUTDOORS), FITTINGS,
VALVES, ETC., CONTINUOUS THROUGH SLEEVES, HANGERS, ETC., WITH 1/2" ARMAFLEX. INSTALLATION
SHALL BE CONDENSATION -FREE, AND INSTALLED ACCORDING TO MANUFACTURER'S
RECOMMENDATIONS.
PIPE HANGERS AND SUPPORTS:
PIPE SUPPORT: ATTACH LINES SECURELY ALONG PAD/FLOOR/EQUIPMENT/STRUCTURE TO PREVENT
MOVEMENT. SUPPORT IN A MANNER THAT LINES DO NOT HANG FROM EVAPORATOR CONNECTIONS OR
BLOCK ACCESS TO FILTERS, CONTROLS, ETC.
HANGERS AND SUPPORTS
PROVIDE ALL NECESSARY DUCTWORK, PIPE SUPPORTS, HANGER, RODS, CLAMPS AND ATTACHMENTS
TO PROPERLY INSTALL AND SUPPORT DUCTWORK, PIPING AND EQUIPMENT FROM THE BUILDING
STRUCTURE.
PROVIDE ANY ANGLE IRON OR UNISTRUT AND SUSPENSION RODS REQUIRED TO INSTALL EQUIPMENT,
PIPING AND DUCTWORK.
ALL SUPPORTS EXPOSED TO OUTDOORS SHALL BE CLEANED, PRIMED AND PAINTED TO PREVENT
RUSTING. FINISH COLOR AS SELECTED BY OWNER.
THE USE OF BALING WIRE OR PERFORATED METAL STRAPPING IS NOT ACCEPTABLE FOR SUPPORTS
EXHAUST FANS:
FURNISH EXHAUST FANS WITH PERFORMANCE AND CAPACITIES AS LISTED ON THE DESIGN DRAWINGS.
ALL EXHAUST FANS SHALL COME WITH INTEGRAL BACKDRAFT DAMPERS.
COORDINATE WITH ARCHITECT TO LOCATE EXHAUST FANS, EXHAUST GRILLES, WALL OR ROOF CAPS A
MINIMUM DISTANCE OF 10'-0" FROM ANY OPERABLE WINDOW, DOOR OR FRESH AIR INTAKE.
AIR DISTRIBUTION EQUIPMENT:
GRILLES, REGISTERS, AND CEILING DIFFUSERS SHALL BE FURNISHED AS SCHEDULED ON THE DESIGN
DRAWINGS AND SHALL BE ALL ALUMINUM CONSTRUCTION. AIR DISTRIBUTION SHALL NOT EXCEED NC-30
NOISE CRITERIA AS DEFINED IN THE LATEST ASHRAE GUIDE.
MATERIALS: GALVANIZED STEEL OF GAUGES CONFORMING TO LATEST EDITION OF SMACNA
STANDARDS BASED ON 2" W.G. PRESSURE UNLESS SPECIFICALLY NOTED OTHERWISE ON THE
DRAWINGS. THE GALVANIZED DUCT COATING IS TO BE G-90. ALL DIMENSIONS ARE INSIDE NET FREE
AREA. SEAL ALL JOINTS AND SEAMS WITH MEDIUM PRESSURE DUCT SEALANT. R-6 FIBERGLASS
DUCTBOARD WITH ANTI -MICROBIAL COATING MAY BE SUBSTITUTED; "SUPERDUCT" OR EQUAL.
ADJUSTABLE SPLITTERS AND DAMPERS SHALL BE INSTALLED IN EVERY SPLIT AND BRANCH DUCT AND
SHALL BE PROVIDED WITH LOCKING QUADRANTS ON EXPOSED OR INACCESSIBLE AREAS OF THE DUCT
FOR EASE OF OPERATION. ACCESS PANELS OR YOUNG REGULATORS SHALL BE PROVIDED WHERE
DAMPERS ARE INSTALLED ABOVE HARD CEILINGS OR IN SOFFITS. EXTRACTORS SHALL BE INSTALLED IN
ALL BRANCH DUCTWORK LEADING FROM TRUNK LINES.
ELBOWS OR CHANGES IN DUCT DIRECTION GREATER THAN 45 DEGREES SHALL BE FITTED WITH AIR
TURNS CONSISTING OF BLADES OR VANES WHICH WILL PERMIT THE AIR TO MAKE ABRUPT TURNS
WITHOUT APPRECIABLE TURBULENCE.
EXTERNALLY INSULATE ALL SHEET METAL DUCTWORK EXCEPT EXHAUST DUCTWORK WITH 2" THICK
MANVILLE R SERIES MICROLITE TYPE 100 OR EQUAL. INSULATION TO HAVE UL FIRE HAZARD
CLASSIFICATION OF FLAME SPREAD 25, SMOKE DEVELOPED 50, FUEL CONTRIBUTED 50. INSTALL PER
SMACNA, FLORIDA MODEL ENERGY EFFICIENCY CODE AND MANUFACTURER'S RECOMMENDATIONS.
SEAL WITH FABRIC TAPE AND MASTIC.
CONTRACTOR SHALL BE RESPONSIBLE FOR FURNISHING AND INSTALLING ADEQUATE AND PROPER
INSULATION AND MOISTURE SEAL IN A MANNER THAT PERMANENTLY PREVENTS THE ACCUMULATION OF
OBJECTIONABLE MOISTURE ON ALL PARTS OF THE SYSTEMS. CONTRACTOR SHALL CORRECT THE
CAUSE OF ANY CONDENSATION AND FULLY REPAIR, WITHOUT COST TO THE OWNER, ANY DAMAGES TO
BUILDING SURFACES, FURNISHINGS, OR EQUIPMENT CAUSED BY CONDENSATION FROM MECHANICAL
SYSTEMS FOR THE FULL WARRANTY PERIOD.
VIBRATION ISOLATION:
ALL BLOWER UNITS AND VIBRATING TYPE EQUIPMENT SHALL BE PROPERLY FITTED WITH MASON
INDUSTRIES VIBRATION ISOLATION EQUIPMENT SIZED IN ACCORDANCE WITH EQUIPMENT WEIGHT AND
DUTY.
PROVIDE FLEXIBLE CONNECTORS AT ALL SUPPLY AND RETURN CONNECTIONS TO AIR HANDLING
EQUIPMENT CONSISTING OF HEAVY CANVAS OR NEOPRENE FABRIC WITH AIRTIGHT SEAMS AND
CONNECTIONS TO THE EQUIPMENT.
FILTERS SHALL BE 1" FIBERGLASS MEDIA THROWAWAY TYPE IN A RIGID FRAME WITH A SUPPORTING
MAZE ACROSS BOTH ENTERING AND LEAVING SURFACES. SUPPLY ONE COMPLETE SET OF FILTERS
PRIOR TO TEST AND BALANCE (FARR 30/30 OR EQUAL).
FIRE DAMPERS
FIRE DAMPERS SHALL BE INSTALLED AT ALL RATED WALL, CEILING AND FLOOR PENETRATIONS. ALL
PENETRATIONS OF RATED WALLS, CEILINGS AND FLOORS SHALL BE INSTALLED IN ACCORDANCE WITH
NFPA 90A AND SHALL BE A U.L. ASSEMBLY.
ACCESS DOORS
CONTRACTOR SHALL PROVIDE ACCESS DOORS FOR DAMPERS, VALVES, ETC. WHERE FLOORS, WALLS,
AND CEILINGS MUST BE PENETRATED TO ACCESS MECHANICAL EQUIPMENT.
H.V.A.C. LEGEND
DOUBLE LINE SINGLE LINE
DUCT DIMENSION A x B
A x B (A = HORIZONTAL, B = VERTICAL)
DUCT W/ACOUSTICAL LINER
SPIN -IN FITTING W/DAMPER
(SIDE TAPPING)
900 ELBOW WITH TURNING VANES
RADIUS ELBOW
SUPPLY AIR DUCT UP �--�
tSUPPLY AIR DUCT DOWN-�
RETURN AIR DUCT UP
RETURN AIR DUCT DOWN
EXHAUST AIR DUCT UP �--�
EXHAUST AIR DUCT DOWN
RIGID ROUND DUCT UP
(2:::; ; RIGID ROUND DUCT DOWN-?-�
41444444,
EXISTING DUCTWORK TO BE REMOVED 65%661, �
MANUAL VOLUME DAMPER
FIRE DAMPER
F F
FIRE/SMOKE DAMPER 16
FS FS
SMOKE DAMPER
S S
SMOKE DETECTOR
s s
MOTORIZED DAMPER
® SUPPLY AIR CEILING DIFFUSER
LLJ
zRETURN OR TRANSFER AIR REGISTER z
z
EXHAUST GRILLE
SUPPLY, RETURN, EXHAUST OR TRANSFER AIR DEVICE
A f- (REFER TO SCHEDULE)
100 -- _- AIR QUANTITY (CUBIC FT. PER. MIN.)
THERMOSTAT or TEMP. SENSOR W/CONTROL WIRING
DRAWING HEX NOTE
POINT OF REMOVAL FOR EXISTING EQUIPMENT
POINT OF CONNECTION BETWEEN EXISTING AND NEW
REVISION DELTA AND NUMBER
DOOR UNDERCUT (MINIMUM 1")
PIPE ANCHOR
PIPE CAP
PIPING TURNED DOWN (PLAN VIEW)
PIPING TURNED UP (PLAN VIEW)
1-- CD CONDENSATE DRAIN
MECHANICAL DRAWING INDEX
M1.1 H.V.A.C. SPECIFICATIONS AND LEGEND
M2.1 H.V.A.C. FLOOR PLAN & DETAILS
M3.1 H.V.A.C. SCHEDULES & DETAILS
P1.1 PLUMBING FLOOR PLAN,
SCHEDULES & DETAILS
FAX
ENGINEERING & CONSULTING, INC.
820 De La Bosque
Longwood, FL 32779
P: (407) 904-1969 F: (407) 540-9403
mbrooks@mbengineer.com
FL License 57671
po
0
�U
b
�
m�
�
a
0
aI
E"'
�
O
rO
Cd
V
.d
.� (
(d
4
0
E a
DRAWN
MLB
CHECKED
MLB
DATE
JUNE 13 2005
SCALE
AS NOTED
PROJECT NO.
24015.3
1150 & 1160
SPINNER LANE
SHEET
m I A
6
3
r
Y
C
CO1MOLTANT
P.O. INK 5mm
CNLA1D0 !!O=► 32M
N8-7M FAX
•
ENGINEERING & CONSULTING, INC.
820 De La Bosque
Longwood, FL 32779
P: (407) 804-1969 F: (407) 540-9403
mbrooks@mbengineer.com
FL License 57671
e®
V 164
•�
g �
V U
bd
o Cd
td
q 4-1
C x
a Er O Cd
( b
0
r
6
I
t
v
A.
DRAWN
MLB
CHECKED
MLB
DATE
JUNE 13 2005
SCALE
AS NOTED
PROJECT NO.
24015.3
1150 & 1160
SPINNER LANE
SHEET
M2ml
t
6
N
■ (ten e0e-?M FAX
ENGINEERING & CONSULTING, INC.
820 De La Bosque
Longwood, FL 32779
P: (407) 804-1969 F: (407) 540-9403
mbrooks@mbengineer.com
FL License 57671
Cd
b
O
K
DRAWN
MLB
CHECKED
MLB
DATE
JUNE 13 2005
SCALE
AS NOTED
PROJECT NO.
24015.3
1150 & 1160
SPINNER LANE
SHEET
M3ml
PLUMBING
PART GENERAL
1.1 SECTION INCLUDES
A. GENERAL PROVISIONS SPECIFICALLY APPLICABLE TO DIVISION
15 SECTIONS, IN ADDITION TO DIVISION 1 - GENERAL
REQUIREMENTS.
1.2 SCOPE
A. THE WORK SHALL INCLUDE THE PROVISIONS OF SYSTEMS,
EQUIPMENT AND MATERIALS SPECIFIED IN THIS DIVISION AND AS
CALLED FOR ON THE DRAWINGS. WORK SHALL ALSO INCLUDE
SUPERVISION, OPERATION, METHODS AND LABOR FOR THE
FABRICATION, START-UP AND TESTS FOR A COMPLETE OPERATIONAL
PLUMBING INSTALLATION.
B. DRAWINGS FOR THE WORK ARE DIAGRAMMATIC IN NATURE AND
ARE INTENDED TO CONVEY THE SCOPE OF THE INSTALLATION AND TO
INDICATE THE GENERAL ARRANGEMENT AND LOCATIONS OF THE WORK.
BECAUSE OF THE SCALE OF THE DRAWINGS, CERTAIN BASIC ITEMS
SUCH AS PIPE FITTINGS, ACCESS PANELS, AND SLEEVES MAY NOT
BE SHOWN. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR
SELECTING THE EQUIPMENT TO FIT THE SPACE PROVIDED. THE
LOCATION AND SIZES FOR PIPE FITTINGS, SLEEVES, INSERTS,
FIRE AND/OR SMOKE DAMPERS, AND OTHER BASIC ITEMS REQUIRED
BY CODE AND OTHER SECTIONS SHALL BE COORDINATED AND
INCLUDED FOR THE PROPER INSTALLATION OF THE WORK.
C. EQUIPMENT SPECIFICATIONS MAY NOT DEAL INDIVIDUALLY WITH
MINUTE ITEMS REQUIRED SUCH AS COMPONENTS, PARTS, CONTROLS
AND DEVICES WHICH MAY BE REQUIRED TO PRODUCE THE EQUIPMENT
PERFORMANCE SPECIFIED OR AS REQUIRED TO MEET THE EQUIPMENT
WARRANTIES. WHERE SUCH ITEMS ARE REQUIRED, THEY SHALL BE
INCLUDED BY THE INSTALLER OF THE EQUIPMENT, WHETHER OR NOT
SPECIFICALLY INDICATED IN THE CONTRACT DOCUMENTS WITH NO
ADDITIONAL COST INCURRED.
D. WHERE NOTED ON THE DRAWINGS OR INDICATED IN OTHER
SECTIONS OF THE SPECIFICATION, THE CONTRACTOR FOR THIS
DIVISION SHALL INSTALL PLUMBING EQUIPMENT FURNISHED BY
OTHERS, AND SHALL MAKE ALL FINAL CONNECTIONS. CONTRACTOR
SHALL INSTALL EQUIPMENT AND SYSTEMS IN STRICT ACCORDANCE
WITH MANUFACTURERS RECOMMENDATIONS.
E. COORDINATE WITH ALL TRADES IN SUBMITTAL OF SHOP
DRAWINGS. TIGHT SPACE CONDITIONS SHALL BE DETAILED TO THE
SATISFACTION OF ALL TRADES, SUBJECT TO THE REVIEW AND FINAL
ACCEPTANCE OF THE ARCHITECT/ENGINEER. IN THE EVENT THAT
THE CONTRACTOR INSTALLS HIS WORK BEFORE COORDINATING WITH
OTHER TRADES OR SO AS TO CAUSE ANY INTERFERENCE WITH THE
WORK OF THE OTHER TRADES THIS CONTRACTOR SHALL MAKE ALL
REQUIRED CHANGES TO CORRECT THE CONDITION AT NO ADDITIONAL
COST TO THE PROJECT.
F. CONTRACTOR SHALL VERIFY ALL EQUIPMENT CONNECTION SIZES
PRIOR TO INSTALLATION OF ANY SYSTEMS. THIS CONTRACTOR SHALL
ADJUST PIPING SYSTEM SIZES AS REQUIRED TO MATCH EQUIPMENT
CONNECTIONS. UTILIZE REDUCERS WHERE EQUIPMENT CONNECTIONS
ARE SMALLER THAN PIPE SIZES INDICATED ON PLANS, NO PIPING
SHALL BE DECREASED IN SIZE (IN THE DIRECTION OF FLOW).
G. EXAMINATION OF BIDDING DOCUMENTS:
1. EACH BIDDER SHALL EXAMINE THE BIDDING DOCUMENTS
CAREFULLY AND NOT LATER THAN TEN (10) DAYS PRIOR TO THE
DATE FOR RECEIPT OF BIDS, SHALL MAKE WRITTEN REQUEST TO
THE ENGINEER FOR INTERPRETATION OR CORRECTION OF ANY
AMBIGUITY, INCONSISTENCY OR ERROR THEREIN. ANY
INTERPRETATION OR CORRECTION WILL BE ISSUED AS AN
ADDENDUM BY THE ENGINEER. ONLY A WRITTEN
INTERPRETATION OR CORRECTION TO BID DOCUMENTS BY
ADDENDUM SHALL BE BINDING. NO BIDDER SHALL RELY UPON
ANY INTERPRETATION OR CORRECTION GIVEN BY ANY OTHER
METHOD.
H. SUBSTITUTIONS
1. EXCEPT AS PROVIDED BELOW, EACH BIDDER
REPRESENTS THAT HIS BID IS BASED UPON THE MATERIALS AND
EQUIPMENT DESCRIBED IN THE BIDDING DOCUMENTS.
2. NO SUBSTITUTIONS FOR OTHER MATERIALS AND
EQUIPMENT WILL BE CONSIDERED UNLESS WRITTEN REQUEST HAS
BEEN SUBMITTED TO THE ENGINEER FOR APPROVAL AT LEAST
TEN (10) DAYS PRIOR TO THE DATE FOR RECEIPT OF BIDS.
EACH SUCH REQUEST SHALL INCLUDE A COMPLETE DESCRIPTION
OF THE PROPOSED SUBSTITUTE, THE NAME OF THE MATERIAL OR
EQUIPMENT FOR WHICH IT IS TO BE SUBSTITUTED, DRAWINGS,
CUTS, PERFORMANCE AND TEST DATA OR INFORMATION
NECESSARY FOR A COMPLETE EVALUATION.
3. IF THE ENGINEER APPROVES ANY PROPOSED
SUBSTITUTION, SUCH APPROVAL WILL BE ISSUED AS AN
ADDENDUM FORWARDED TO ALL PARTICIPATING BIDDERS.
4. IF ANY BIDDER IS UNABLE TO PROCURE WRITTEN
APPROVAL OF ANY SUBSTITUTION FROM THE ENGINEER PRIOR TO
THE OPENING OF BIDS, THEN HE SHALL BASE HIS BID ON
ITEMS AND SYSTEMS AS SPECIFIED IN BID DOCUMENTS.
5. SUBSTITUTIONS REQUESTED ON THE BID PROPOSAL
FORM WHICH ARE PRIOR APPROVED BY THE ENGINEER WILL BE
INCORPORATED INTO THE CONTRACT WITH THE SUCCESSFUL
BIDDER.
6. REQUESTS FOR ANY SUBSTITUTIONS NOT SUBMITTED
AND APPROVED IN ACCORDANCE WITH THE ABOVE INSTRUCTIONS
WILL BE DENIED BY THE ENGINEER.
1.3 REGULATORY REQUIREMENTS
A. ALL INSTALLATIONS AND EQUIPMENT SHALL BE IN STRICT
ACCORDANCE WITH ALL APPLICABLE STATUTES, CODES AND
REGULATIONS OF THE GOVERNMENTAL BODIES HAVING JURISDICTION.
B. CONFORM TO 2001 FLORIDA BUILDING CODE (WITH 2O03 REVISIONS).
C. CONFORM TO 2001 FLORIDA PLUMB ING,MECHANICAL AND FUEL GAS
CODES (WITH 2O03 REVISIONS)
D. CONFORM TO 2001 FLORIDA FIRE PREVENTION CODE.
E. NATIONAL ELECTRIC CODE 2002 EDITION,
F. NFPA 54 (NATIONAL FUEL GAS CODE).
1A CUTTING AND PATCHING
A. Employ skilled and experienced installer to perform cutting and patching.
exposed or moisture - resistant elements.
B. Submit written request in advance of cutting or altering elements which effect:
1. Structural integrity of elelsed elements.
2. Integrity of weather-
3. Efficiency, maintenance, or safety of element.
4. Visual qualities of sight
5. Work of Owner or separate contractor.
PART 2 PRODUCTS
2.1 PIPE HANGERS AND SUPPORTS
A.MANUFACTURERS:
1. B-LINE.
2.OTHER ACCEPTABLE MANUFACTURERS OFFERING
EQUIVALENT PRODUCTS.
A) MICHIGAN HANGER.
B) PHD.
2.2 HOT WATER WATER PIPING INSULATION
A. Manufacturers:
1.Owens-Coming
2. Johns -Manville
3. Knauf
B. ASTM C547, rigid molded non-combustible fiberglass insulation.
'K' value .024 at 75 degrees F.
C. Vapor Barrier Jacket, Kraft paper with glass fiber yarn and bonded to aluminized film
Closure system shall be UL 181.
D. Insulation Thickness: 1-1/2"
2.3 PIPING: SANITARY SEWER PIPING, BELOW AND ABOVE GRADE
A. PVC: ASTM D2665 SCHEDULE 40 PVC PIPING/
1. FITTINGS: SCHEDULE 40 PVC.
2. JOINTS: CASTM D2855 SOLVENT WELD WITH ASTM D2564 SOLVENT CEMENT
2.4 PIPING: WATER PIPING, ABOVE GRADE
A. COPPER PIPING: ASTM B88 TYPE'L' HARD DRAWN.
1. FITTINGS: ASTM B16.8 CAST BRONZE ORASTM B16.22 WROUGHT
COPPER OR BRONZE.
2. JOINTS: ASTM B32 SOLDER, ASTM 95TA MINIMUM.
PART 3 INSTALLATION
A. INSTALL IN STRICT ACCORDANCE WITH MANUFACTURER'S
INSTRUCTIONS.
B. TORQUE ALL HUBLESS CAST IRON COUPLINGS IN STRICT
ACCORDANCE WITH THE MANUFACTURERS RECOMMENDATIONS. UTILIZE
COUPLING MANUFACTURERS PRE-SET TORQUE WRENCH.
C. PROVIDE NON -CONDUCTING DIELECTRIC CONNECTIONS WHEREVER
JOINTING DISSIMILAR METALS.
D. ROUTE PIPING IN ORDERLY MANNER AND MAINTAIN GRADIENT.
E. INSTALL PIPING TO CONSERVE BUILDING SPACE AND NOT
INTERFERE WITH USE OF SPACE.
F. GROUP PIPING WHENEVER PRACTICAL AT COMMON ELEVATIONS.
G. INSTALL PIPING TO ALLOW FOR EXPANSION AND CONTRACTION
WITHOUT STRESSING PIPE, JOINTS, OR CONNECTED EQUIPMENT.
H. PROVIDE CLEARANCE FOR INSTALLATION OF INSULATION AND
ACCESS TO VALVES AND FITTINGS.
I. PROVIDE ACCESS WHERE VALVES AND FITTINGS ARE NOT
EXPOSED. COORDINATE SIZE AND LOCATION OF ACCESS DOORS WITH
APPROPRIATE ARCHITECTURAL SECTION.
J. ESTABLISH ELEVATIONS OF BURIED PIPING OUTSIDE THE
BUILDING TO ENSURE PROPER SLOPE AND COVER.
K. ESTABLISH ELEVATIONS OF EXISTING BURIED PIPING FOR
CONNECTION TO NEW WORK TO ENSURE PROPER SLOPE AND COVER.
L. WHERE PIPE SUPPORT MEMBERS ARE WELDED TO STRUCTURAL
BUILDING FRAMING, SCRAPE, BRUSH CLEAN, AND APPLY ONE COAT
OF ZINC RICH PRIMER TO WELDING.
M. EXTEND CLEANOUTS TO FINISHED FLOOR OR WALL SURFACE.
LUBRICATE THREADED CLEANOUT PLUGS WITH MIXTURE OF GRAPHITE
AND LINSEED OIL. ENSURE CLEARANCE AT CLEANOUT FOR RODDING
OF DRAINAGE SYSTEM.
N. ENCASE EXTERIOR CLEANOUTS IN CONCRETE FLUSH WITH GRADE.
0. INSTALL EACH FIXTURE WITH TRAP, EASILY REMOVABLE FOR
SERVICING AND CLEANING.
P. PROVIDE CHROME PLATED RIGID OR FLEXIBLE SUPPLIES TO
FIXTURES WITH LOOSE KEY STOPS, REDUCERS, AND ESCUTCHEONS.
Q. INSTALL COMPONENTS LEVEL AND PLUMB.
R. INSTALL AND SECURE FIXTURES IN PLACE WITH WALL
SUPPORTS, WALL CARRIERS AND BOLTS.
S. SEAL FIXTURES TO WALL AND FLOOR SURFACES WITH SEALANT
AS SPECIFIED IN SECTION 07900, COLOR TO MATCH FIXTURE.
CONTRACTOR SHALL KEEP AS -BUILT PLANS DURING CONSTRUCTION
INDICATING ALL DEVIATIONS FROM CONTRACT DOCUMENTS INCLUDING
ALTERED PIPE ROUTING.
PLUMBING
SYMBOL LEGEND
-- SAN --
SANITARY PIPING ABOVE GRADE
-- SAN - -
SANITARY PIPING BELOW GRADE
-
DOMESTIC COLD WATER PIPING
VENT PIPING
0
PIPING ELL DOWN
0
GATE VALVE
n' �'
BALL VALVE
0
FLOOR CLEANOUT
BE
EXTERIOR CLEANOUT
Q5
CONNECT TO EXISTING
D4 -
GATE VALVE IN SERVICE BOX
WATER CLOSETS
LAVATORIES
ELM
SHOWER VALVE
1 1 • L:. � ti�
TRAP PRIMER
► 1 M717, i•t 3 57'w
PLUMBING FIXTURE SCHEDULE
I &=1 FIXTURE AMERICANI STAIN m 'CADET" NO. 2898.012, WHITE VITREOUS CHINA, FLOOR MOUNTED,
FLUSH TANK, 12" ROUGH -IN, 1.6 GALLONS PER FLUSH, 2' GLAZED TRAPWAY, CLOSE -
COUPLED TANK AND LID, TRIP LEVER.
SEAT BE MIS TOILET SEAT NO. 1955C, WHITE, HEAVY -DULY PLASTIC, ELONGATED, OPEN FRONT, LESS COVER,
STAINLESS STU POST SELF-SUSTAINING CHECK HINGES.
STOP MICGUIRE NO. H172-M CHROME PLATED ANGLE LOOSE -KEY STOP, 12' LONG COPPER TUBE RISER
AND ESCUTCHEON.
1=1 FIXTURE
AMERICAN STANDIARD 1UCERNE' N0. 0355.012, WHITE VITREOUS CHINA, WALL HUNG, CONCEALED ARM,
ADA COMPLIMIT. 4' CENTER FAUCET DRILLING, FRONT OVERFLOW, BACKSPLASH.
FAUCET
AMERICAN STANM 'REI.WNT +' NO. 2385.406, CHROME PLATED BRASS CONSTRUCTION, 4' (ENTEIM,
ADA COMPLIANT, 0.50 GPM VANDAL RESISTANT AERATOR, LESS POP-UP AND POP-UP HOLE, CERAMIC DISC
VALVE CARTRIDGE. ADJUSTABLE HOT LIMIT SAFETY STOP.
DRAIN
M cGUIRE MANUFACTURING NO. 155-WC, CHROME PLATED BRASS CONSTRUCTION, ADA COMPLAINT,
OFFSET GRID STRAINER, P-TRAP (SEE TPV-A BELOW) WITH CLEANOUT, NIPPLE AND ESCUTCHEON.
STOPS
MICGUIRE NO. H170-M CHROME PLATED ANGLE LOOSE KEY STOPS, 12' LONG COPPER TUBE RISERS
AND ESCUTCHEONS.
1 FIXTUIRE
ELKAY 1LUSTER7ONE' NO. LRAD1716, 118 GAUGE TYPE 304 (18-8) STAINLESS STEEL SINK, 170645,
SINGLE BOWL, ADA COMP", FULLY SOUND DEADENED, SELF -RIMMING, U-CHANNEL, THREE FAUCET HOLES.
FAUCET
AMERICN STAWM 'COLONY' NO. 2475.500.002, CHROME PLATED BRASS CONSTRUCTON, TWO LEVER,
ADA COMPLIANT. HIGH GOOSENECK, CERAMIC DISC OPERATION.
DRAIN
ELKAY NO, UCVR18V, STAINLESS STEEL GRID STRAINER FOR SIN( 3-1/2' DRAIN OUTLET.
STOPS
MCGURE NO. H170-LK, CHROME PLATED ANGLE LOOSE -KEY STOPS, 12" LONG COPPER TUBE RISERS
AND ESCUTCHEONS.
2 1. VALVE
SYMMONS 'TDMPTROL I' NO. BP-56-500-B30-L-V-X, CHROME PLATED BRASS CONSTRUCTION,
PRESSURE BALANCED MIXING VALVE, ADA C011PI.WIT. LEVM HANDLE, ADJUSTABLE STOP SCREW LIMIT,
SHOWER HEAD WITH ARM AND ESCUTCHEON, LEVER DIVEIM WITH INTEGRAL VOLUME CONTROL,
WALL/WAD SHOWER MmFHF1DgBt,E 1ETAI x HOSE, IN-uNE WICUUM BREAKER, WALL CONNECTION
AND FLANGE. 30' SLIDE -BAR FOR HAND SHOWER MOUNTING.
DRAIN
ZURN NO. ZN415S. SQUARE POLISHED NIM BRONZE TOP, CAST IRON BODY, BOTTOM = ET,
COMBINATION INVERTABLE MEMBRANE CLAMP, ADJUSTABLE COLLAR, SEEPAGE SLOTS, HEEL -PROOF
STRAINER. PROVDE WITH DEFT' -SEAL CAST IRON P-TRIP.
BL1
ZURN N0. Z415-S-P, SQUARE POLISHED NICKEL BRONZE, CAST IRON BODY, BOTTOM OUTLET,
COMBINATION INVERTABLE MEMBIRANE CLAMP AND ADJUSTABLE COLLAR WITH SEEPAGE SLATS,
1 /2' TRAP PRIMER CONNECTION.
IBC_]
ZURN NO. Z1021, LAVATORY TRAP WITH WATER SAVER TRAP PRIMER FITTING. PIPE TO DRAIN BELOW SLAB.
1 1 7 1• 'IN 7•
�1 " �' M : 7' • •�7.`t " �II71 M to,
to 971 1 • 1 is 7
1 3. •� 1 '�71 1 �►�
F- PLUMBING FIXTURE CONNECTION SCHEDULE
(TEEM
DESCRIPTION
I WASTE
I TRAP
I VENT
CW
HW
REMARKS
WC-1
WATER CLOSET
4"
INTEG
2"
1 2
-
L-1
LAVATORY
2"
1-1/4*
S-1
SINK
2"
1-1 /2"
SH-1
SHOWER 1
2" 1
2"
1-1 2
1 2
1 2
EXISTING C SANITARY
SEWER BELOW GRADE.
(NEW TOTAL 2001 FPC DRAINAGE
FIXTURE UNITS: 22).
FLOOR PLAN - PLUMBING
SCALE 1/8 =1'-0'
`EXISTING 3' VTR
\ 3'
IN
1-1/2'
EXISTING 4' BUDLNG v
DRAIN 1
2"
3'FD-1
i
SANITARY RISER DIAGRAM
NOT TO SCALE
EXISTING 1-1/4'
3/4'
3/4" I I 1
EXISTING 3/4' l`
SEA (•)
DOMESTIC WATER RISER DIAGRAM
'11A ll
LO
I
UNION
TEMPERATURE
do PRESSURE
RELIEF VALVE
ELECTRIC WATER
HEATER, SEE SPEC. `
AND SCHEDULE-� I
DRAIN VALVE
PIPE FULLSIZE
TO HUB DRAIN
'OACUUM RELIEF
1ALVE
;HECK VALVE
TALL VALVE
ANSION TANK
iAL TO AMTROL
1
IDRAIN PAN GALV. SHEET
/-METAL 3" DEEP MIN.
ELECTRIC WATER HEATER DIAGRAM
NOT TO SCALE
ENGINEERING & CONSULTING, INC,
820 De La Bosque
Longwood, FL 32779
P: (407) 804-1969 F; (407) 540-9403
mbrooks@mbengineer.com
FL License 57671
'o
2
q
0
Fi
of
ECd
DR
ad
g
0
A a
d
M0
T/1
DRAWN
MLB
CHECKED
MLB
DATE
JUNE 13 2005
SCALE
AS NOTED
PROJECT NO.
24015.3
1150 & 1160
SPINNER LANE
SHEET
P I
1
a
=
�
�
�
�
w
m
1\ 'THE GENERAL CONDITIONS AND THE SUPPLEMENTARY CONDITIONS OF THE ARCHITECT
SHALL BE CONSIDERED AS PART OF THIS SPECIFICATION.
2` THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING. BIDS SHALL SERVE AS
EVIDENCE OF KNOWLEDGE OF ALL EXISTING SITE CONDITIONS. FIELD VERIFY THE
'EXISTING ELECTRICAL AND TELEPHONE SITE CONDITIONS AND ROUGH -IN /|F ANY).
3\ CONTRACTOR TO VERIFY TH[ INTERCONNECTION REQUIREMENTS OF EACH ELECTRICAL
SYSTEM BETWEEN THIS SPACE AND ANY OTHER ATTACHED SPACE . THESE
REQUIREMENTS ARE TO BE INCLUDED IN BID.
4\ FURNISH ALL LA80R, MATER|ALS, EQUIPMENT, AND TOOLS TO PERFORM THE
ELECTRICAL WORK AS INDICATED FOR A COMPLETE AND OPERABLE INSTALLATION,
5` THE ELECTRICAL CONTRACTOR SHALL PROVIDE TEMPORARY SERVICE, 9NR|NC, POWER,
AND L|QHTS AS REQUIRED. TEMPORARY SERVICE SHALL MEET ALL NEC AND OSHA
REQUIREMENTS CONCERNING GROUND FAULT PROTECTION. UPON COMPLETION OF
PROJECT, CONTRACTOR SHALL REMOVE ALL COHDU|T, CONDUCTORS, DEVICES, ETC.,
ASSOCIATED WITH TEMPORARY SERVICE AND WIRING.
0\ ELECTRICAL CONTRACTOR SHALL RECORD AIL FIELD CHANGES IN HIS WORK AS THE
JOB PROCRESSES, AND UPON COMPLETION SHALL TURN OVER TO THE GENERAL
CONTRACTOR A RECORD SET OF PRINTS SHOWING THESE CHANCES.
1` COMPLY WITH LOCAL CODES, STATE CODES, AND NATIONAL ELECTRICAL CODE (NEC),
AND ALL APPLICABLE REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION AT THE
5|T[.
2) WHERE THE REQUIREMENTS OF ANY OF THE AUTHORITIES LISTED ABOVE DIFFER
FROM THE PLANS OR SPECIFICATIONS, THE MOST STRINGENT REQUIREMENTS TAKE
PRECEDENCE.
J\ OBTAIN PERMITS FROM THE AUTHORITIES HAVING JURISDICTION AND TURN OVER TO
THE GENERAL CONTRACTOR,
1\ ALL MATERIALS USED IN THIS PROJECT SHALL BE NEW UNLESS OTHERWISE NOTED
AND SHALL BE LISTED BY THE UNDERWRITER'S LABORATORIES, INC., AS CONFORMING
TO ITS STANDARDS WHERE SUCH STANDARDS HAVE BEEN ESTABLISHED. THESE
MATERIALS SHALL BEAR THE LISTING MARK OF THE UL,
2) SUBMIT MATERIALS LIST AND SHOP DRAWINGS FOR ALL MAJOR EQUIPMENT
PROPOSED FOR THIS WORK TO THE GENERAL CONTRACTOR FOR RENEW. SUBMITTALS
SHALL BE IN ACCORDANCE WITH THE GENERAL CDNO|T|0N3 AND SHALL BEAR THE
APPROVAL OF THE ELECTRICAL CONTRACTOR SHOWING THAT HE HAS RENEWED THEM
AND THAT THE PROPOSED MATERIALS ARE EQUIVALENT TO OR BETTER THAN THE
SPECIFIED MATER|�LS AS INDICATED ON THE DRAWINGS AND AS SPECIFIED HEREIN.
]) CONTRACTOR SHALL PROVIDE AND INSTALL THE SPECIFIED MANUFACTURER AND
MODEL NUMBER OF LIGHT FIXTURES AND LAMPS AS INDICATED ON THE LIGHTING
FIXTURE SCHEDULE. THE CONTRACTOR SHALL PROVIDE ADEQUATE INFORMATION ON
ANY PRDP03[O EXCEPTION TO THE SPECIFIED UST NO LESS THAN THREE (3) DAYS
PRIOR TO BID DAT[. PROVIDE MANUFACTURER AND MODEL NUMBER 0F PROPOSED
EXCEPTIONS AND. IF REQUESTED, PROVIDE CUT SHEET, PHOT0WETR|CS, AND
SAMPLES. FIXTURE SUBMITTALS NOT AS SPECIFIED AND PROVIDED AFTER 8|D
WITHOUT PRIOR APPROVAL WILL NOT BE ACCEPTED FOR REVIEW.
1\ GROUND THE SYSTEM IN ACCORDANCE WITH ARTICLE 250 OF THE LATEST ADOPTED
ISSUE OF THE N.E.C.
2) ALL EQUIPMENT, MOTOR, FIXTURE, RECEPTACLE, OR DEVICE TO WHICH CURRENT
CARRYING N� CONDUCTORS ARE CONNECTED SHALL HkA SEPARATE GREEN
EQUIPMENT GROUNDING CONDUCTOR, SIZED IN ACCO�DANCE WITH N.E.C. TABLE
250-95. AND TO BE INSTALLED IN THE RACEWAY AND CONNECTED TO THE DEVICE.
3\ ALL GROUNDING OR BONDING CONDUCTORS SHALL BE SIZED AS REQUIRED BY THE
NEC AND SHALL BE THWN/THHN INSULATED WITH GREEN COLOR CODING.
4\ ALL ELECTRICAL EQUIPMENT ENCLOSURES AND CONDUCTOR ENCLOSURES SHALL BE
GROUNDED.
1) SAFETY SWITCHES SHALL BE GENERAL DUTY SAFETY SWITCHES WITH 10lOOOA
SHORT CIRCUIT RATING AND SHALL BE LISTED IN ACCORDANCE WITH Ul. 98. THE
COVER SHALL BE INTERLOCKED S0 THAT THE DOOR CANNOT BE OPENED WITH THE
HANDLE IN THE 'ON' POSITION, EXCEPT BY THE INTENTIONAL OPERATION OF A
CONCEALED RELEASE OEFEATER\ MECHANISM. PROVIDE NEWA 1 ENCLOSURES FOR
INTERIOR LOCATIONS 4ND HEMA 3R ENCLOSURES FOR EXTERIOR LOCATIONS.
;\ SAFETY SWITCHES AND DISCONNECTS SHALL BE FUSED (FOR A/C EQUIPMENT AS
PER U1, LISTING AND LOCAL CODE REQU|REME NON -FUSED AS INDICATED
ON DRAWINGS OR AS REQUIRED BY THE NEC. SW|TCH[S SHALL BE W&NUFACTUR[U
BY GENERAL ELECTRIC, SQUARE O. SIEMENS, WECTINaIDUSE, OR EQUIVALENT.
J) PROVIDE ENGRAVED PHENOLIC NAMEPLATES FOR ALL SAFETY SWITCHES INDICATING
EQUIPMENT SERVED.
W FUSES TO BE BUSSWAN TYPE' DUAL -ELEMENT, TIME DELAY, TYPE RK5.
1) PROVIDE A COMPLETE BRANCH CIRCUIT WIRING, STARTER AND DISCONNECT SWITCH
FOR ALL MOTOR DRIVEN EQUIPMENT. WHEN MOTOR DRIVEN EQUIPMENT IS PROVIDED
WITH 'PACKAGE' CONTROL PANEL WHICH INCLUDES STARTER, THIS CONTRACTOR WILL
NOT PROVIDE STARTER. MOTOR CONNECTIONS SHALL BE MADE WITH FLEXIBLE
CONDUIT.
0 FIXTURE SCHEDULE SHOWS REQUIRED TYPE OFFIXTURES ONLY. DETERMINE
MODIFICATIONS REQUIRED TO MAKE FIXTURES SUITABLE FOR CEILINGS AS INSTALLED.,
AND FURNISH FIXTURES ADAPTED TO THE CEILING USED, FIXTURES SHALL BE U.L.
APPROVED. THIS CONTRACTOR SHALL PROTECT THE FIXTURES AND LAMP3, AND
SHALL REPLACE BROKEN PARTS. ALL LENSES AND LOUVERS IN ANY AREAS SHALL
BE CLEANED AFTER ALL TRADES HAVE COMPLETED THEIR WORK IN THAT AREA.
PROVIDE NEW LAMPS FOR ALL LIGHTING FIXTURES.
�ITO-TE-Iffil �3
1\ ALL RACEWAY ROUTED CONCEALED ABOVE CEILING OR IN WALL SHALL BE EMT.
MINIMUM SIZE OF RACEWAY SHALL BE 1/2". UNDERSLA8 OR UNDERGROUND
CONDUIT SHALL BE SCHEDULE 40 PVC CONDUIT. CONDUIT EXPOSED TO THE
OUTSIDE ABOVE THE GROUND TO BE GALVANIZED STEEL.
2) SIZE CONDUIT PER N.[CFOR ENCLOSED WIRING.
3\ FITTINGS SHALL BE APPROVED AND U.L. LISTED FOR THE RACEWAY INSTALLED.
4) PROVIDE PULLSTRINGS IN ALL EMTPY CONDUITS.
5\ ALL CONDUIT -TERMINATING IN OUTLETS JUNCTION DK PULL BOXES, AND CABINETS
MUST TERM|NAT[ WITH A LOCKNUT AND BUSHING, EXCEPT AT EXPOSED CAST BOXES
WHERE THEY MAY BE OMITTED. RIGID CONDUIT SHALL BE INSTALLED WITH DOUBLE
L0CKNUT3 AND BUSHING.
6) COUPLINGS, CONNECTORS, AND FITTINGS FOR EMT SHALL BE STEEL SETSCREW.
7> FLEXIBLE METAL CONDUIT SHALL BE USED FOR CONNECTIONS TO LIGHTING RXTURES,
FIXED APPLIANCES AND MOTORS WHERE FLEXIBILITY |S REQUIRED. F|XTURE WHIPS
WAY BE 1/2^ TO 3/8" TO INDIVIDUAL FIXTURES AND ALL OTHER SHALL BE 1/2"
8 FLEXIBLE CONDUIT EXPOSED TO MOISTURE SHALL BE LIQUID TIGHT FLEXIBLE METAL
CONDUIT, EXCEPT WHERE LIQUID TIGHT FLEXIBLE NONMETALLIC CONDUIT |S PERMITTED
BY LOCAL AUTHORITY.
g\ PVC CONDUIT SHALL BE 'INSTALLED WITH FACTORY ELBOWS AND FITTINGS. USE ONLY
APPROVED SOLVENT CLUE FOR THE CONDUIT AND FITTINGS. FIELD BENDING OF PVC
CONDUIT MAY BE PERFORMED ONLY WITH THE CONDUIT MANUFACTURER'S "HOT 8OX"
APPROVED BENDERS.
10) ALL CONDUCTORS MUST BE IN A RACEWAY. NO BX OR R0W[X ALLOWED.
1\ ALL CONDUCTORS SHALL BE #12COPPER (MINIMUM) WITH THHN/THWN|NSULATION
AND SHALL CONFORM TO THE CURRENT ISSUE OF THE N.E.C. ARTICLES 308 AND
310. AND SHALL MEET ADTW SPECIFICATIONS. ALL CONDUCTORS SHALL BE NEW
FREE OF KINKS AND OTHER DEFECTS WHEN INSTALLED.
2) MINIMUM WIRE SIZE SHALL BE NO. 12 NO. 14 FOR CONTROL WIRING) AND
SHALL BE SOFT DRAWN COPPER, SOLID WITH THWN/THHN INSULATION IN SIZES
THROUGH NO. 10 AND STRANDED WITH THWM/THHN INSULATION FOR NO. D AND
LARGER.
3N INSULATION SHALL BESUITABLE FOR 600 VOLTS AND MUST BEAR THE CONDUCTOR
SIZE, TYPE OF INSULATION, AND THE MANUFACTURER'S NAME STAMPED AT REGULAR
4) COLOR CODE SHALL IDENTIFY THE SAME PHASE THROUGHOUT THE SYSTEM FROM
MAIN SWITCH THROUGH ALL BRANCH CIRCUITRY.
1) PROVIDE ALL SUPPORTS FOR MATERIAL AND EQUIPMENT.
LTITK!-Ij nk r&
1) A COMPLETE SYSTEM OF CONDUCTORS SHALL BE INSTALLED FOR ALL FEEDERS
BRANCH CIRCUITS, AND CONTROL CIRCUITS AS NOTED ON THE PLANS.
?\ NO WIRE IS TO BE INSTALLED IN RACEWAY UNTIL THE ENTIRE RACEWAY SYSTEM IS
COMPLETE AND THEN ONLY WITH THE USE OF AN APPROVED WIRING LUBRICANT.
3) BRANCH CIRCUIT SIZES ARE NOTED ON THE PLANS AND MUST BE CONTINUOUS
WITHOUT REDUCTION IN SIZE THROUGHOUT THEIR LENGTH BETWEEN FIXTURE, EXCEPT
WHERE CONNECTING TO FIXTURES. BRANCH CIRCUITS EXCEEDING 70 FEET IN TOTAL
'LENGTH SHALL BE A MINIMUM OF NO, 10 AWS TO THE FIRST OUTLET (THIS DOES
NOT APPLY TO CIRCUITS WITH LARGER THAN NO. 12 CONDUCTORS ALREADY
INDICATED ON PLANS).
41 AUJW|NUW CONDUCTORS TO TERMINATE IN COMPRESSION BARRELS USING
AN'11-OXIDATION PASTE AND MANUFACTURER ACCEPTABLE COMPRESSION TOOL.
ALUMINUM CONDUCTORS TO BE USED FOR PANEL FEEDERS AND ON! Y WHERE
APPROVED BY OWNER.
1) PROVIDE ALL NECESSARY WIRING, BOXES AND RELATED ACCESSORIES REQUIRED BY
LOCAL TELEPHONE COMPANY FOR COMPLETE PREY0RED UNIT |NSTALLATON OF
TELEPHONE SERVICE TO TELEPHONE COMPANY INTERFACE.
1\ THE F0LLDWING UIT[O HUBBELL DEVICES WAY BE THE PRODUCT OF EAGLE P & Si
OR ARROW -HART, BUT MUST BE EQUIVALENT TO THE DEVICES LISTED AND MUST BE
IDENTIFIED IN THE SUBMITTALS. ALL DEVICES SHALL BE GANG MOUNTED WHERE
POSSIBLE.
M SWITCHES:
SINGLE POLE, 20 AMPERES, 120/277 VOLT: CS120-W
3) RECEPTACLES:
4) �E�0ROFA��R|NQD�C��A�BE|��UN��O����N0�DR
AS APPR0VED/D|RECTED BY THE ARCHITECT COVER PLATES SHALL BE PLASTIC,
COLOR TO WATCH THE ASSOCIATED DEVICE.
1\ THE ELECTRICAL CONTRACTOR SHALL MAKE ALL POWER CONNECTIONS TO MOTORS,
STARTERS, EXHAUST FANS, WATER HEATERS, ETC., INCLUDING ALL THE ONES
INSTALLED BY THE HVAC AND PLUMBING CONTRACTORS. ALL CONTROL WIRING NOT
INDICATED ON THE PLANS WILL BE THE RESPONSIBILITY OF OTHER TRADES.
?\ THE ELECTRICAL CONTRACTOR MUST OBTAIN ROUGH -IN INFORMATION FROM OTHER
CONTRACTORS AND VERIFY THE ACTUAL PURCHASED EQUIPMENT PRIOR TO
INSTALLATION.
3) VERIFY THE -THERMAL CONDITIONS UFTHE EQUIPMENT BASED ONNAMEPLATE DATA
AND CONNECT AS THE LISTING REQUIREMENTS ARE STATED USING THE SPECIFIED
MATERIALS.
4\ ALL POWER AND CONTROL CIRCUITS FOR ELECTRICAL EQUIPMENT REQUIRING
ELECTRICAL CONNECTIONS ARE BASED ON THE DESIGN AS INDICATED WITHIN THE
CONTRACT DOCUMENTS. THE DIVISION 16 TRADESMAN SHALL VERIFY ALL
PURCHASED EQUIPMENT THAT REQUIRES ELECTRICAL CONNECTION WITH THE
RESPONSIBLE CONTRACTOR OR VENDOR PRIOR TO ELECTRICAL ROUGH -IN, ANY
DEVIATIONS IN EQUIPMENT ROUGH -IN REQUIREMENTS FROM THE CONTRACT
DOCUMENTS SHALL BE CONSIDERED A COORDINATION ITEM THAT THE ELECTRICAL
T RADESMAN SHALL DISCUSS WI TH THE OTHER TRADES INVOLVED.
1\ PANELBOARD3, LOAD CENTERS CIRCUIT BREAKERS DISCONNECT SWITCHES,
STARTERS AND OTHER APPARATUS USED FOR THE OPERATION AND CONTROL OF
CIRCUITS, APPLIANCES AND EQUIPMENT SHALL BE PROPERLY IDENTIFIED BY MEANS
OF ENGRAVED LAMINATED PLASTIC DESCRIPTIVE NAMEPLATES MOUNTED ON THE
APPARATUS USING PERMANENT CONTACT CEMENT.
1\ MATER|ALS, E0U|PWEN[ AND INSTALLATION SHALL BE GUARANTEED FOR A PERIOD
OF ONE YEARFROM THE DATE OFACCEPTANCE.
ALL M0UN|TNG HEIGHTS ARE TO THE CENTER OF DEVICE, UNLESS SHOWN DR NOTED
OTHERWISE:
SWITCH: 48" A.F.F.
RECEPTACLE: 18^ A.F.F. OR AS NOT
TELEPHONE: ON CENTERLINE OF ADJACENT DEVICES (RECEPTACLES).
DISCONNECT SWITCH: NOT LESS THAN 24^ A.F.F. OR A.F.C. AND NOT MORE THAN
6 ..... 5" A.F,F. OR A.F.G. TO 'TOP OF HANDLE, UNLESS SHOWN OR NOiED OTHERWISE.
GENERAL ELECTRICAL
'EC7-[]|CA| hJ OT[-S
1. ALL 120V 20A CIRCUIT HOMERUNS OVER 150FT SHALL BE #8 CU. kWN0MUW. UNLESS
NOTED OTHERWISE.
2. THE USE OF ANY PROCESS INVOLVING ASBESTOS OR PCB, AND THE INSTALLATION
OF ANY PRODUCT, INSULATION, COMPOUND OF MATERIAL CONTAINING OR
INCORPORATING ASBESTOS OR PCB, IS PROHIBITED. THE REQUIREMENTS OF THIS
SPECIFICATION FOR A COMPLETE AND PROPERLY OPERATING ELECTRICAL SYSTEM
SHALL BE MET WITHOUT THE USE OF ASBESTOS OR PCB.
J. THE POWER COMPANY SHALL BE CONTACTED WITHIN 10 DAYS OF THE AWARD OF
THE CONTRACT BY THE CONTRACTOR TO VERIFY THE ACTUAL AVAILABLE SHORT
CIRCUIT FAULT CURRENT \ AT THE- TRANSFORMER SECONDARY BUSHINGS. THE
CONTRACTOR SHALL PROVIDE ELECTRICAL DISTRIBUTION AND UTILIZATION EQUIPMENT
AND PAN[LBOAROS WHICH HAVE A|C/WITHSTAND RATINGS GREATER THAN THE
AVAILABLE SSC AT EACH POINT IN THE ELECTRICAL SYSTEM.
4. VISIT THE SITE AND CAREFULLY EXAMINE THOSE PORTIONS OF' THE SITE AFFECTED
BY THIS WORK BEFORE SUBMITTING PR8POSALS, S0 AS TO BECOME FAMILIAR WIT[-]
THE EXISTING CONDITIONS AND DIFFICULTIES THAT WILL AFFECT EXECUTION OF THE
W0RK, SUBMISSION OF A PROPOSAL WILL BE CONSTRUED AS EVIDENCE THAT SUCH
EXAMINATION HAS BEEN MADE AND LATER CLAIMS FOR LA8OR, EQUIPMENT OR
MATERIALS REQUIRED BECAUSE OF DIFFICULTIES ENCOUNTERED WILL NOT BE
RECOGNIZED.
5. ALL WORK TO BE PERFORMED IN ACCORDANCE WITH NEC 2002 AND ALL OTHER
CODES AND REGULATIONS OF AUTHORITIES HAVING JURISDICTION.
0
mmnurno1
�
�
CHECKED
DATE
SCALE
AS No-rED
1150 & 1160
SPINNER / ANE
SHEET
El ml
-2
-3
-b
_j
-2
-3
-3
ELECTRICAL ABBREVIATIONS
ELECTRICAL SYMBOL LEGEND
A
AMPERE
EXIT FIXTURE — SINGLE OR DOUBLE FACE
DIRECTIONAL ARROWS AS SHOWN ON PLANS
AFF
ABOVE FINISHED FLOOR
WALL MOUNTED LIGHTING FIXTURE, 6" ABOVE THE MIRROR
AFG
ABOVE FINISHED GRADE
2'X4' RECESSED FLUORESCENT TROFFER
C
CONDUIT
BATTERY OPERATED EMERGENCY LIGHT FIXTURE
C. 13.
CIRCUIT BREAKER
$
SWITCH — SINGLE POLE (DOUBLE POLE FOR 208V CIRCUITS)
EF
EXHAUST FAN
qp
DUPLEX RECEPTACLE, NEMA 5-20R, IG — ISOLATED GROUND RECEPTACLE
EWH
ELECTRIC WATER HEATER
FF
FINISHED FLOOR
q)
DOUBLE DUPLEX OR QUAD TYPE RECEPTACLE, NEMA 5-20R
GFI
GROND FAULT INTERRUPTING
14
DUPLEX RECEPTACLE MOUNTED 6" ABOVE THE BACKSPLASH OR AS NOTED
GND
GROUND
COMBINATION VOICE/DATA OUTLET
M.L.O.
MAIN LUGS ONLY
PROVIDE VOICE/DATA CABLE PER OWNER REQUIREMENTS
TTB
TELEPHONE TERMINAL BOARD
JUNCTION BOX
TYP
-TYPICAL
PANELBOARD, 240/120V
�—
XFMR
TRANSFORM[R
1, 3,5
HOMERUN TO PANEL (ONE ARROW PER CIRCUIT)
v
VOLT
3/4"D x 4'H x 4' PLYWOOD TELEPHONE/DATA TERMINAL BACKBOARD
WID
WEATHERPROOF OR NEMA 3R
N 0 TIE:
ALL INDICATED MOUNTING HEIGHTS ARE TO THE CENTER OF DEVICE UNLESS OTHERWISE
SHOWN OR NOTED.
LIGHT FIXTURE SCHEDULE
- --- - ----- - --- - ---
LIGHT FIXTURE DATA
------------ - -- - ------- -
------
LAMP DATA
BALLAST DATA
DESCRIPTION
ID MANUFACTURER MODEL NUMBER
---------- --------
TYPE WATTS QTY.
TYPE
VOLTS
A DAYBRITE 2SPF432—FS1 2— 120-1/4—EB
F32T8 32 3 4
ELECTRONIC
1 Zu RECESSED FLUORESCENT PRISMATIC TROFFER. 2'X4'
.................... ... ........................................................................ ............................................. ............................................. ...........
FLUORESCENT
........................... ...........................
B2 DAYBRITE CD220W— 120
.......... .................. ................ ................ ....... ...............
Q OT 12 20 1 2
...................................... ...................................
ELECTRONIC
.................................................................................................................................. .................................... ....................
120 2' FLUORESCENT WALL BRACKET
- - ------ -- - - ------_---------- ----------- ............... ... . . --- ------- -
FLUORESCENT
6" ABOVE THE MIRROR ON CENTER
-- — - ------
C DAYBRITE 2SP'F231 U6—FS1 2-120-1/2—EB
T8 I 32 2
ELECT-RONIC
— -----
120 RECESSED FLUORESCENT PRISMATIC TROFFER, 2'X2'
FLUORESCENT
EM MCPHILBEN CAX6
MR1 6 5 2
i
120 EMERGENCY BATTERY FIXTURE, 2—HEAD
........... ...... ...... I .......................................................................
HALOGEN i
.............. ............................................................................ .............
X MCPHILEIEN CCAXL— 1 —G—W—H
........................ I ............ ................. . ....... ......... .......... ........ .................................. ..... .................................................
LED
.................
.......... ....... .... ...................... .. ....... ....................................................... ......... ............ ............ .......... .......... ....................
120 SINGLE FACE GREEN STENCIL FACE WALL MOUNTED LED EXIT
HALOGEN
LIGHT WITH WHITE HOUSING, DIRECTIONAL ARROWS
AS INDICATED ON PLANS, EMERGENCY NI —CAD BATTERY
-N.O.TIS:
1, PROVIDE ENERGY SAVING LAMPS AND ELECTRONIC BALLASTS,
2. ALL EXIT AND BATTERY PACK LIGHT FIXTURES SHALL BE CONNECTED AHEAD OF ROOM LIGHT SWITCHING.
-5. EQUAL MANUFACTURERS TO BE LITHONA LIGHTOLIER AND COOPER.
1/4" = 1'-0'
IQEW
BUS AMPS: 225
MAIN AMPS: 225 M.C.B.
SERVICE: ZLO 120 V
KVA
PHASE: 1
WIRE:
OPTIONS:
OTHER _LTG REC '
--XIS TING LOAD SERVED
_L 0A D
2.25 WATER HEATER EWH-11
2.25
...................................... I ....... ......................... .................. ...........................................................
I I SIPACE'
GENERAL ELECTIRICA-L N.OTES:
1. ALL CONDUIT THROUGH WALL, FLOOR OR CEILING PENETRATIONS TO BE
SEALED WITH A FIRE RESISTIVE COMPOUND OF SAME FIRE RATING AS THE
WALLS, FLOORS OR CEILINGS THEY PENETRATE (TYP.).
2, ALL HOMERUNS TO BE #10 THHN/THWN CU. IN 3/4" EMT C. MINIMUM,
UNLESS SHOWN, NOTED OR SPECIFIED OTHERWISE.
3. ALL EXIT AND EMERGENCY BATTERY BALLASTS OF LIGHT FIXTURES TO BE
CONNECTED AHEAD OF LOCAL SWITCHING,
4. ALL ELECTRICAL EQUIPMENT SHOWN DASHED IS EXISTING TO REMAIN,
UNLESS SHOWN OR NOTED OTHERWISE (TYP.).
5. ALL NEW LIGHT FIXTURES SHOWN ON THIS PLAN ARE TYPE W, UNLESS
INDICATED OTHERWISE, REFER TO LIGHT FIXTURE SCHEDULE, THIS
DRAWING.
6, FOR THE TELEPHONE SERVICE WITHIN THIS AREA, UTILIZE EXISTING
TELEPHONE TERMINAL BOARD LOCATED IN THE CLOSET OF EXISTING
OFFICE SPACE.
KEY NOTES:
1:1:::� EXISTING PANELBOARD AND POWER CO.'S METER WITH BASE.
LUG LOCATION: TOP
MOUNTING: SURFACE
TYPE: SQUARE D, HOMELINE
CB
CKT,
BUS
CKT.
CB
:'OLE
TRIP
NO.
A 8
NO.
TRIP POLE
LOAD SERVED
40
1
2
30 2
'_XISTING Lf-"AD
..................
....... ... .
..................
4
20
.............
1
............ .....
..... 5 ......
.... ....................
.... ..........
.. ........... .......
6
.... ..
.... .... .................
....... . ......... ........ ............... ..................
...... .... .......
8
...................... .....................
.... .... .... .... .... ....
......... ....................................................................
9
10
2012
20 1
RECEPT., OFFICE
25
2
13
lo
14
20 1 1
RE C E P T. KITCHEN
---
...................
---
15
......................................
16
20 1
RECEPT.KITCHEN
........ ..................
.......................
18
.............
..................................................................
21
.,
............
...... ..........17
I LTG., OFFICES
19
.... ......
....................................
20
. .. .........RECEPT,
20 1
. ....... ...... ........... .....................................
*--***..............
OFFICE
r —ICE
21
22
— — ----- ------------- —
23
0
24
.................
.............. ....
25
..................
40
....
26
.
....................
27
.................... ..
40
..................
28
. .................. ...........
...... ...... ........ . ................
.................
29
... ......... ........ ..
.. ...........
30
................. . ... ...............
. ...... .......... ...................................
31
32
33
34
35
36
................
37
4o
38
..................
39
.... ................... ...
........
..... .......... .........
............................ .........
41
t
42
....................
......... ................... ................................
i
PROVIDE:
HACK TYPE CIRCUIT BREAKERS SERVING HVAC EQUIPMENT
UPDATED TYPEWRITTEN DIRECTORY
NORTH ELECTRICAL PLAN - LIGHTING
------r--
1/4" = 1'—o"
CIRCUITS: 42
AIC RATING: 10 K
CONNECTED KVA
DEMAND FACTOR
DEMAND KVA
TOTAL, DEMAND KVA
DEMAND AMPS
REC
0.90
1.80
1,80
0.90
KVA
---- — -----
LTG I OTHER
1.20
1.0 11.25 1; 1.0
z
.�2
N
.2
0
ca
CD
�7—
E
Yi
.2
E
0
.2
fx
co
r_
cn
_u
0
0
C.
0
21
CD
CD
0
0
L A
Ld
ID
CL
0
Q
KD
r!
0
0
C
0
0
sz
CD
E
:3
.0
Ld
tJ
Ld
(D
CONSTRUCTION —A—
DD
MSTRATION .... IN
:CONSULTANT ---------------------- — --
P.O. 13OX 561227
ORLANDO, FLORIDA 32856
(401) 898-7992 FAX
r tems
Elactric.6 Engineering & ConSLJ]t;ng
/`!. license 460953
11655 Swift Water Circle
Orlando, Ft 52a17
PhonulTax: 407.24,3.6020
czpowersystemsgbellsouth. net
Q)
0
>
C)
�7-
(D bJ
4--)
C
111110 ml,
AEZ
CHECKED
AEZ
64-11-TE
J1JNE 13, 2005
SCALE
AS NOTED
------ — ------ — --------------
PROJECT NO.
2 40 1 .5.3
1150 & 1160
SPINNER I ANE
SHEET
Im
E2ml
-2
� � }
.: Spinner Lane
: < �\ , 1140 Spi y»� » «, n
Hangar
Permit NO2