HomeMy WebLinkAbout3085 St Johns Pkwy 04-389, 04-674 Sprinklers and New Constructionr f , A SANFORD FIRE DEPARTMENT } FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, FI. 32772 (407302-2520 / FAX (407) 302-2526) Pager (407) 918-0395 Plans Review Sheet Date: December 19, 2003 Business Address: 3085 St. Johns Parkway Oce. Ch. 40 Industrial Business Name: Sanford Auto Auction (Service area) Ph. ( ) Contractor: Wigginton Fire Sprinkler• Inc. Ph. (407) 831-3414 FAX (407) 831-5740 Reviewed f l Reviewed with comment [X ] Rejected l l Reviewed by: Timothy Robles, Fire Protection Inspector/Plans Examiner Ordinary Hazard Group two (2)= MAXIMUM STORAGE 12' FEET HIGH IN WAREHOUSE Per design criteria (see street file) Comment: Instillation of 109 —(Tyco Heads) 12 - Tyco '/2" Tyco Chrome Rec. heads K- factor 5.65 97- Tyco 3/4" 165 degree heads S.R. BR. SSU Heads Application— Per N.F.P.A. #13-1999 ed, 2-1.1 * Service area is designed as "Ordinary Hazard Group #2" • 2 Hour hydro and flush on under ground • 2 hour above hydro • Tamper switches required on all outside and inside fire sprinkler valves, including all outside valves • Backflow Prevention valves • Water flow switch required on riser • Label fire inspectors test valve • No storage in ware house over 12' ft high per design criteria Place signs on inspectors test reading (Inspectors Test Valve) . Oyp", i FLOW TEST EFFECTIVE HERE POINT OF CONNECTION - BEGIN SCOPE OF WORK STATIC: 68 PSI RESIDUAL: 58 PSI WIGINTON FIRE SYSTEMS TO PERFORM FLOW: 1890 GPM WET TAP OF EXISTING 8" CITY WATER DATE: 9/26/03 MAIN WITH 8"x6" M.J. TAPPING SLEEVE BY: CITY OF AND 6" M,J.xFLG. RESILIENT WEDGE, SANFORD N,R.S, GATE VALVE & ROAD BOX, STRAIGHT PATTERN ROUGH BRASS F.D.C. AND WAFER CHECK VALVE (SEE D TAIL).—-6" M.J. C,ATE VA. UG2 ROAD BOX (SEE D BF1 I CD CD I'LUME 1(IYP) NEW 3-WAY FIRE - ---- . �l ) l POINT OF SERVICE , HYDRANT (SEE DETAIL) P NORTH - _...... W/ ETAIL) r IJ - - - —�_ � -- i ? t , 6 } I i � I I o 4" FIRE SPRINKLER RISER. SEE SHEET FP2 FOR DETAIL. SEE THIS SHEET FOR LEAD-IN DETAIL. 00 h-- 49.-5" DL _i AIL L3LDC FIRE PROTECTION SITE PLAN 10 15 Q 15 310 SCALE 1"=30' UNUtKUKUUNU NU I tJ 1) UNDERGROUND PIPING TO BE DR-18 CLASS 150 PVC UPSTREAM OF B,F,P. DOWNSTREAM OF B.F.P. PIPING SHALL BE DR-14 CLASS 200 PVC. 2) PIPE TO BE INSTALLED 36" BELOW GRADE, WITH PIPE LETTERING FACING UP. PROVIDE METALLIC BURY TAPE ABOVE ALL PVC PIPE. 3) UNDERGROUND PIPING INSTALLATION TO MEET THE REQUIREMENTS OF NFPA 24 AND CITY OF SANFORD UTILITIES STANDARDS, 4) SEE PRODUCT SUBMITTAL DATA PACKAGE FOR ALL UNDERGROUND MATERIAL SPECIFICATIONS TO BE USED ON THIS PROJECT. FINISH GRADE OR PAVING ADJUSTABLE SLIDING --- TYPE ROADWAY BOX SERVICE BOX W/ "WATER" CAST IN COVER II � AWWA VALVE � r UNDERGROUND PIPING AWWA VALVE D ETA! L NOT TO SCALE NOTE: 4 1/2 PORT SHALL ALWAYS FACE STREET OR DRIVEWAY _zQ HYDRANTS TO BE INSTALLED AT BETWEEN 4' AND 18' OFF odd CURB UNLESS OTHERWISE -N DIRECTED BY CITY. GRADE OR ROAD 6" AWWA VA. W/ RWB 6" M.J. TEE 6" FIRE MAIN 6" B.B. PVC TO HYDT. PUMPER HYDRANT �\ �� 5-1/4" BARREL FIRE HYDRANT DETAIL NOT TO SCALE 4" FLANGED TEE 4" WAFER CHECK VALVE 4%0-4 THRD.xFL GALV. NIP. A- 4%2-1/2%2-1/2" R.B. CM F.D.C. W/ BREAK CAPS--' 4" FEBCD MODEL 856 DOUBLE CHECK DETECTOR BACKFLOW PREVENTER 4" OS&Y RESILIENT WEDGE / GATE VA, W/ TAMPER SWITCH / (TYPICAL FOR 2) 4" FLANGED ELL 36" MIN. 4" M.,. 90' ELL RESTRAINED WITH MEGA -'LUGS 4" BLUE BRUTE PVC l CLASS 200, DR-14 4"6" RED. M.J, 90' ELL RESTRAINED WITH MEGA LUGS GRADE 4" x 5-0 FLxPL CL. 50 D.I. SPIGOT (TYP. FOR 2) 6 BLUE BRUTE PVC CLASS 150, DR-18 BACKFLOW PREVENTER DETAIL NOT TO SCALE CV 4" DR-14 C-900 //,--4" UNIFLG. FIN. 4" x 5-0 PLxPL CL.50 D.I. PIPE W/ FACE OF UNIFLG. @ 12" AFF 4" M.J. ELL W/ MEGA —LUG RESTRAINT SPIGOT DETAIL NOT TO SCALE NO. DATE REVISION DESCRIPTION BY Ujiginton A" FIRE PROTECTION ENGINEERING, INC. ■ Orlando, Florida Tampa, Florida ❑ West Palm Beach, Florida (407) 831-3414 Office (813) 623-2333 Office (561) 540-4420 Office 407 831-5740 Fax 813 620-0333 Fax 561 540-4490 Fox ❑ Jacksonville, Florida El Miami, Florida El Melbourne, Florida 904 262-6107 Office 305 888-2402 Office 407 722-5585 Office 0 12/5/03 ISSUE FOR AHJ APPROVAL SAS 904 262-6108 Fax 305 888-3804 Fax 407 722-4775 Fax k J , ., . _- REVIEWED By� Sanford re eve tion Div. Date: --___.__La MCI®? RECD nFr. 0 2003 N L N CD 01 N O �� is -"4 co �t Cn a— U W Q W Z 0_ CAS �Q W rn 2 F- Q _M O 10 a00 WIGIATOA Rff INUIS INITIALS DATE STATUS �o71t° 12/5/03 SUBMITTAL FAB & INSTALL AS—BUILTS FIRE PROTECTION SITE PLAN S.A.D.E. DETAILING BLDG. 2851 JEWETT LANE SANFORD, FLORIDA 32711 DRAWN BY: S. SCHRADER DATE: OCTOBER 10, 2003 SPRKS. ON JOB:109 SCALE: 1" = 39 APPROVALS: CITY OF SANFORD CUSTOMER NAME: MCKEE CONSTRUCTION CONTRACT NO. 2010188 1 SHEET NO. FP1 OF 2 LEGEND Q NEW BRASS UPRIGHT HEAD O NEW PENDENT HEAD WITH RECESSED ESC. NEW BRANCH LINE NEW MAIN PIPE HANGER O HYDRAULIC CALCULATION NODE POINT 4"0" RED. GRV. COUP. 3" TO SYSTEM H3 o �. 2„ CL] I / 6 HEAD CAB, W/ TYP. ALL WRENCH .... BRANCHLINES ON 4 0 _ FLOW SWITCH THIS AREA ally (off ALARM BELL 4" RISER CHECK VALVE OVERHEAD DOOR IS CANIISTER ROLL I TAI H11/I i ii (i9^�'� / H4 ' I ' `'1' t1" W/ TRIM. (G-G) UP TYPE. NO HEADS REQUIRED.--,,,,,f / AREA* ! / O,f + I , DETAILING , I OVERHEAD DOOR IS CANIISTER ROLL E c T 3' 4 200 �� ! ��/�•�\� RN 1\'� UP TYPE. NO HEADS REQUIRED. o 1 1 I I c, <0 ! `_ 0-4 �� 3' �`' 3' �`' 3' �� 3' 0 3` �� 3' �� 3" �� 3' �� 3' �� 3' it / 4 a� 3'�� / 3' % i 01 I f s II 1 3. 114'-2 1/2" -I ' 4,Iry 13-2 12-10 12-6 5-11 5-4 11-3 11-3 11-3 11-10 12-6 I 12-10 13—f I �c 1 T RN3 RN2 0— ! I 4yj/ // x 2 DRATCD > 2 ^ v' FIN. FLOOR NORTH RE SPRINKLER PLAN 1/8" = l'-O" �Iy I SCALE 1 /8"=1 '-0" 4" CL. 50 D.I. SPIGOT, SEE SHEET FP1 FOR LEAD-IN DETAIL. RISER DETAIL NOT TO SCALE STRUCTI IDAI FRAMIN( SELF -DRILLING, SELF - TAPPING METAL ANCHOR EQUAL TO "SAMMY' DSTR V W/ RET. NUT ALL -THREAD ROD HANGER RING HANGER #12A BOTTOM STEEL ANCHOR STEEL AND/OR CPVC PIPING UP TO4' DIA. 1-1/2' 1 Z"x 1 1. GRV. ADA-CAP - I r\ 1" GLOBE VA.-\ DESIGN NOTES 1) NEW WET PIPE OVERHEAD SPRINKLER SYSTEM DESIGNED IN ACCORDANCE WITH NFPA 13-1999 FOR THE FOLLOWING: A) DETAILING AREA: ORDINARY HAZARD GROUP II MISC. STORAGE OCCUPANCY, NOT TO EXCEED 12 FEET IN STORAGE HEIGHT. MAX. HEAD SPACING NOT TO EXCEED 130 S.F. B) OFFICES: LIGHT HAZARD OCCUPANCY. MAX. HEAD SPACING NOT TO EXCEED 225 S.F. SEE TITLEBLOCK FOR HYDRAULIC CALCULATION DESIGN INFORMATION, AND HEAD SELECTIONS, 2) ALL WORK SHALL BE DONE IN ACCORDANCE W/ NFPA 13-1999 AND LOCAL CODES, 3) ALL HANGERS AND MATERIALS TO BE IN ACCORDANCE W/ NFPA 13-1999. 4) PIPE LENGTHS NOTED CENTER TO CENTER. 5) HEADS ARE TO BE INSTALLED UNIFORMLY, BUT ARE NOT REQUIRED TO BE CENTER OF TILE IN OFFICE AREA. 6) NO FIRE EXTINGUISHER, PAITING OF PIPE, WIRING, OR MONITORING SERVICES ARE TO BE PROVIDED BY THE FIRE SPRINKLER CONTRACTOR. 7) ALL CEILING HEIGHTS IN OFFICE AREA ARE TO BE 9'-0" UNLESS NOTED OTHERWISE ON PLAN, HANGER LOCATION DETAIL PIPE SIZE A B C 1" 2'-0" MAX. 6'-0" MAX. 3" MIN. 1 %" 2'—D" MAX. C-6" MAX. 3" MIN. 116" 2'-0" MAX. 7'-0" MAX. 3" MIN. A B* C HANGER RING 4 STEEL PIPE PENDENT SPRINKLER HEAD * MAXIMUM HANGER SPACING FOR THREADED LIGHTWALL STEEL PIPE IS 12'-0" FOR ALL PIPE SIZES HANGER LOCATION DETAIL PIPE SIZE A B* C 1 " S-0" MAX. 12'-0" MAX. 3" MIN. 1 %" 4'-0" MAX. 12'-0" MAX. 3" MIN. 1'/h"-8" 5'-0" MAX. 15'-0" MAX. 3" MIN, A B" ILI C I UPRIGHT SPRINKLER HEAD STEEL PIPE L HANGER RING * MAXIMUM HANGER SPACING FOR THREADED LIGHTWALL STEEL PIPE IS 12'-0" FOR ALL PIPE SIZES I N c O V I I v V \ 0 1" x 1-6 T—T GALV, cV d� V u �1 " GALV. ELBOW N ch cD R SMOOTH BORE CORROSION C-- 3 � ci, CD~— RESISTANT OUTLET GIVING FLOW � Z EQUIVALENT TO ONE SPRINKLER CD.? w � Z INSPECTOR'S TEST DETAIL w N NOT TO SCALE 00 / 00 00 REC�IVED mr1 t�Z03 W16111TOA REr1EWt INITIALS DATE STATUS rrit',l 12/5/03 SUBMITTAL FAB & INSTALL AS-BUILTS OVERHEAD PIPING PLAN WATER SUPPLY ABBREVIATIONS MATERIALS DESIGN CRITERIA HYDRAULICALLY DESIGNED SYSTEM TYPES OF SPRINKLERS NO. DATE REVISION DESCRIPTION BY • • S.A.D.E" DETAILING BLDG. FLOW TEST FIRE PUMP = CENTERLINE SIZE LOCATION TYPE SYSTEM NO. 1 1 LOCATION DETAIL OFFICES SYMBOL QUANTITY K-FACTOR THREAD TEMP. MAKE & MODEL TYPE FINISH ESC. wiginton 2851 JEWETT LANE DATE OF TEST: 9/26/03 RATED CAPACITY: = ELEVATION 1" THREADED BRANCH LINES XL HAZARD OH II LIGHT NO. OF SPRINKLERS 12 11 Q 12 5.6k 1/2" 155° TYCO TY-FRB (Q.R.) SSP CHR REC FIRE PROTECTION SANFORD, FLORIDA 32711 TIME OF TEST: RATED PRESSURE: TOS = TOP OF STEEL 1-112"-4' GROOVED BRANCH, MAIN, RISER DYNAFLO SPACING 130 225 DENSITY .20 .10 Q 97 8.Ok 3/4" 185° TYCO TY-L (S.R.) SSU BR NONE ENGINEERING, INC. DRAWN BY: S.SCHRADER DATE: OCTOBER 10, 2003 STATIC PRESSURE: 68 PUMP TYPE: G = GROOVED PIPE END ALL THREADED COUPS. & FITTINGS D.I. K FACTOR 8.Ok 5.6k DESIGN AREA 1500 900 SPRKS. ON JOB:109 SCALE: 1/8" = T-O" ■ Orlando, Florida � Tampa, Florida � West Palm Beach, Florida 407 831-3414 Office 813 623-2333 Office 561) 540-4420 Office RESIDUAL PRESSURE: 58 WELL PUMP T = THREADED PIPE END 1-1/2" GROOVED COUPS. & FITTINGS STANDARDINSIDE HOSE 0 0 GPM DISCHARGE 598.86 304.3 407 831-5740 Fox �813 620-0333 Fax �561 540-4490 Fox APPROVALS: CITYOFSANFORD GALLONS FLOWING: 1890 GPM AVAILABLE: F = FLANGED PIPE END 2" -4" GROOVED COUPS. & FITTINGS FIRELOCK OUTSIDE HOSE 250 100 RESIDUAL PSI AT 57.227 41.597 CUSTOMER NAME: MCKEE CONSTRUCTION El Jacksonville, Florida El Miami, Florida El Melbourne, Florida 904 262-6107 Office 305 888-2402 Office 407 722-5585 Office TESTED BY: SANFORD PSI AVAILABLE: C-C = CENTER TO CENT R RACK GPM 0 0 CITY 109 HEADS THIS SHEET 0 12/5/03 ISSUE FOR AHJ APPROVAL SAS M4) 262-6108 Fax M5� 888-3804 Fax �407� 722-4775 Fax CONTRACT NO, 2010188 SHEET NO. FP2 OF 2 3- Him. EDGC DIST. FOR vc-m ITV.' Taa[o1e. _'. PAIN. EDGE DIST, FOR 3/8•'o PDWER BOLT— - 3l6- SLIP FOR DOOR '■ EXISTING CONC. OR WIDTH LESS THAN OR 3/8" SLIP FOR DOOR ■ GROUTED FtASONRY EOUAL TO I2"-io I/Z'• ECLUA LESS THAN OR WALL STRUCTURE 4-1/Z'• Mtt.•, EQUAL E S TH •• Ex;srING STEEL JAr;6 SLIP FOP. DOOR WIDTH 1/Z-.. 3!3•' SLIP FOR ODOR GREATER THAN 1Z EDGE D(ST. SLIP FOR DOOR WIDTH N.IN. TNl[.✓,KE55 3!B'=— ' 1R" j GR EA TEE' THAK �lID FH LESS THAN OR j AND LESS THAN IW-10- 12'-10" EQUAL 7D TZ'-1D-. 1/Z" / AND LESS THArr i5'-10 SLIP' FOR DOOR WIDT" / EXISTING CONC. OR T!2" / GROUTED MASONRY FOR FASTENER ! GREATER THAN 72'-10- WALL STRUCTURE MAX. SPACING, (; AN'D LESS THAN w-10••EMBED/ v SEE TABLE i , FOR FASTENER - � x _ MAX. SP ACING, Et-16ED 1; OR FASTENER -W W SEE TABLE t I+ I MAX_ SPACING: SEE TABLE I urn `� " �• '- WIND BAR WIND BAR ANGLE FOR CONCRETE ` i •- INS TALLA FION V� 3 U a �.. WINO BAR D� a m W a. QTYFJCAL PANEL 'MIN.� 1 1•. , \\ .. a e , OI TYPICAL PANEL Mlt:. 2 [HA NNEI GUIDE TYPICAL PANEL MIN. THREE 3r16'-c• ZINC 2QCHAMNEL GUIDE THREE 3/i 6`o ZINC O COVETED STEEL BLIND COATED STEEL BLIND ` ThfREE 3/T6"0 ZINC ZD``'HANNEL GUIDE Y RIVETS RIVETS COATED STEEL BLIND _z iD.IIND LOCK P EVERY �, �` RIVETS ?r OTHER CORROGATIDFJ (3 EACH (DWIND LUCK @ EVERY "r71ND LOCK (� CVERY ENO OF SACK PAKELI OTHER CDP.RUGa 71pN (3 EACH THER CORRUGAT;DR (3 EACH >= END OF Er.CH PANELI END OF EACF PAItE11 WINDLOCK GUIDE CONNECTION VIINDLOCC GUfDE CONNECnON TO CANCRM TO S1 ELIAMB DETAIL Nd{NDLOCIC GUIDE CONNECitOT� TO CONCRETE z' E1 /s OR GROUTED MASONRY DETAIL (IffSIDE GUIDE) OR GROUTED MASONRY DETAIL (OUTSIDE GUIDE) Y� o SCALE= 3" z 1'-D" `EZ �/ SCALE: 3" = 4'-6" F3 SCALE: 3" = 1'-D- 4 TABLE- 1 DOOR SCHEDULE FASTENER MAXIMUM SPACING SUPER7tiPOSCD LOADS DETAIL E1 DETAIL Q DETAIL E2 ' MAX. MAX- 3,1B-o -72 r 1- HEX WASHER HEAD TYPE DETAIL E3 DOOR k'IDTJf DESIGN LOAD V. {P_L.F.? VY 1P.L.F_I B THREAD FORMING ZINC PLATED STEEL SCREW PLUS A 3!8"a FLAT WASHER 3/8"6 POWER BOLT ANCHOR WITH MINIMUM 2" En➢FOMENT 1/f.-O ITW TAPCDN ANCHOR w;TH - 3/3-a+ POWERS RAWL LOK/BOLT SLEEVE MIt.IMUM 1-3/eEMBEDMENT ANCHOR Wi7NMINlHUNi 1-Srs` EMSEOFTENT STEEL STRUCTURE CONCRETE STRUCTURE GROUTED MASONRY STRUCTURE CONCRETE GROUTED MASOKP.Y STRUCTURE CONCRETE GROUTEDhSASOxRY [MIN_ 3000 PS.I.1 [SEE NGTE No_ 2 7 STRUCTURE• {MIN. 314S P5.1.1 ISEE NOTE No. 2 1 STRUCTURE {MIN. 3500 P5.1.1 STRUCTURE {SEE NOTE No. 2 1 n 35.0 810 223 Iz, 5- 1`•rA 7•• 5.. <_ iZ"-T0•• 72' g- 26.0 L78 165 7.. 3" 11- g- - IV-10- a 30.3 1165' 255 g- 12'• 16'-iD" _ z.26.0 452 ZT9 g•• t, •• IhlA T�„ T•. SUPERIMPOSED LOAD DIAGRAM SCALE: 3- = T-O- TAKE 1 NOTES: 1. ENTER TABLE I WITJ{ MAX. DOOR WIDTH & MAX. DESIGN LOAD --SUPERIMPOSED LOADS Va & Vy ARE GIVEN FOR EACH ODOR WIDTH S DESIGN LDAD C0115I64ATIDN {SEE GENERAL NOTE 11 ON SHEET 1 FOR Vx 8, VyK Z. OETERP• wE FASTENER MAX. SPACING EASED ON TYP^ OF DETAIL AND WALL STRUCTURE FOR THE SPECIFIC INS T ALLATt DN. 3. EMBEOfIfNT LENGTH DOES HOT INCLUDE STUCCO FINISH. C. FOR HOLLOW MASONRY, FILL ALL CELLS WITHIN 9'• OF THE ANCHOR W! 2500 PSI GROUT. S. AMCHDRS SHALL 13E INSTALLEO IN ACCOROANCE S•// MANUFACTURERS SPECIFICATIONS. RAT IE ED AN 27 D03 SEMiN.oL.E COUNTY pLANS EXAMINER CL CLOD .'�naffS KH t h dr•i 04lOa12ZQ ��N x 02-292 IL ,Aee P Z a f 2 13r16" 3/8" 13IIr—ttle" I C S16"� i I 9' =TYPICAL PANEL DETAIL SCALE: 3- = I'-O" 20" 3 7/1-" `.oz2'• �� � nor. S/s TYPICAL OVERALL PANEL SCALE: 1-1/2" = F-0" ASTM A79Z GR B❑ ALUM. ZINC ALLOY COATED STEEL 1-1/2" x 1-7rZ- x -10- x CONTINUOUS GALVANIZED STEEL ANGLE FULL I•+ -EIGHT FOR USE ON CONCRETE OR 14ASDNRY INSTALLATIONS 2- 1r2" 5/3Z-0 HOLES _ FOR 3/16'•o ZINC COATED BLIND RIVETS N t!2- WINDLOCK CHANNEL GUIDE SCALE: 3" = 1'-0- ALL COMPONENTS SHALL BE ASTH AS2b STEEL W/ MItf. Py=33 KSI GALV ANGZ ED PER ASTM ASZS G-96 L L NOTES: i. THESE PRODUCT EVALUATION DOCUMERTS REPP.ESENT A OBCI ROLL -UP ODOR .SERIES 31" DESIGNED AND TESTED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE 2001. 2. THIS ROLL -UP DOOR HAS BEEN SUCCESSFULLY TESTED IN ACCORDANCE WITH ASTM E338 TO SAFELY RESIST A POSITIVE OR NEGATIVE WIND LOAD.AS NOTED IN THE DOOR SCtFEDULE. A TEST LOAD OF 1.5 x DESIGN LOAD HAS BEEN USED_ 3. NO RaCREASE IN ALLOWABLE STRESS HAS BEEN USED IN THE DESIGN OE THIS PRODUCT. �. DETERMINE THE POSITIVE AND NEGATIVE DESIGN LOADS TO USE WHEtf REFERENCING THESE DOCUMENTS IN ACCORDANCE WITH THE GOVERNING CODE AND GOVERNING WIND VELOCITY. FOR WEND LOAD CALCULATIONS IN ACCORDANCE WITH ASCE T-96. A DIRECTIONALITY FACTOR OF Kd =0.85 MAY BE USED. 5. THESE PRODUCT £VALUATIQN DOCUMENTS ARE PREPARED BY THE PRODUCT ENGINEER AND ARE GENERIC. THEY DO NOT INCLUDE INFORMATION PREPARED FOR A SPECIFIC SITE. 6. THESE PRODUCT EVALUATION DOCUMENTS ARE NOT VALID FOR PERMIT WITHOUT ORIGINAL SIGNATURE, DATE & EMBUSSED SEAL ON EACH PERMIT COPY. THIS ORIGINAL SIGNATURE AND SEAL REQUIREMENT ES APPLICABLE WHETHER OR NOT A MASTER APPROVAL DOCUMENT IS ON FILE WITH A MUNICIPALITY DR OTHER GOVERNMENTAL AGENCY. 7. THESE PRODUCT EVALUATION DOCUMENTS ARE SUITABLE TO 8E APPLIED BY THE CONTRACTOR PROVIDED THE CONTRACTOR DOES NOT DEVIATE FROM THE CONDITIONS DETAILED HEREIN AND THE CONTRACTOR VERIFIES THE EXISTING STRUCTURE IS CAPABLE OF SUPPORTING THE LOADS_ ` S. ALTERATIONS OR ADDITIONS TO THIS DOCUMENT ARE NOT PERMITTED. 9. WHERE THE,LONTRACTOR. OR THE BUILDING OFFICIAL REQUIRES DOCUMENTS FOR ? SIT- SPECIFIC APPLICATEDN. THESE DOCUMENTS SHALL BE PREPARED BY A FLORIDA REGISTERED ENGINEER OR ARCHITECT FOR SAID APPLICATIOR. 10. WHEN THE SITE CONDITION'S DEVIATE FROM THESE PRODUCT EVALUATION DOCUMENTS. r SETE SPECIFIC DOCUMENTS SHALL BE PREPARED BY A FLORIDA REGISTERED ENGINEER 3 OR ARCHITECT. IF THE DEVIATING SITE SPECIFIC DOCUMENTS ARE PREPARED 6Y A DELEGATED FLORIDA REGISTERED ENGINEER OR ARCHITECT SAID DOCUMENTS E SHALL BEAR', THE DATE, SIGNATURE, AND EM13OSSED SEAL OF THE DELEGATED s ENGIRE-R DR. ARCHITECT AND SHALL BE SUBMITTED TO THE PRODUCT ENGINEER FOR REVIEW. it. DESIGN BASED ON CONSTRUCTION TESTFNG CORPORATION iC.T.C_I TEST REPORT No's, 95-028. AND 95-D29_ 12. SUPERIR!R&SED LOADS ON THE JAMBS FROM THIS DOOR ARE DESIGNATED AS Vx E AND V • HEREIN. CONTRACTORS SHALL HAVE BUILDING ENGINEER VERIFY ADEQUACY OF BUILDING STRUCTURE TO RESIST SUPERIMPOSED LOADS Vx, Vy AND BRACKET LOADS SHOWN. 13. ALL WELDING SHALL BE PERFORMED BY QUALIFIED WELDERS IN ACCORDANCE WITH CONSDRM SPECIFICATIONS. TO ON GADE LATEST EDITION. ALL WELDING ELECTRODES SHALL z iL. DOORS SHALL BE PROVIDED WITH SLIDE LOCK HECHANISKS AT EACH SIDE OF BOTTOM T OF DOOR ENGAGING CHANNEL GUIDES IN THE LOCKED POSITION. ASTM A526 STEEL W! MIN. Fy=33 KS[ GALVANIZED PER ASTM AS25 G-90 1/L", THRU BOLT W/ 1-1/&- x 1-1/4" x 1/8" t LOCK WASHER@ 12- O.C_ TUBE ASTM ASSTEEL a[ L W! MINK. Fy_32 KS[ a75' D75' ITUBB EXTENDS BETWEEN CDNT. GALV. STEE:. `° SLIDE LOCK= F ANGLE AS2b W/ MIN. T— 1/L"0 FHRV BOLT wl 120" Fy=33 KSI , �_ FLOCK WASHER (ol 12- O.C. ITS>J Z;: Z < r- \� Too" _bLD1 - .6L0' �� ... CONFIM1IUO US VINYL CONTINUOUS VINYL WEATHER STRIPPING WEATHER STRIPPING uti ` o g �—' STIFFENER SHALL BE STIFFENER SHALL BE 6a63-T5 AL. ALLOY 6U63-Tb AL. ALLOY in •'a ^ W S v W14DLOCK BOTTOM STIFFENER & ANGLE (TYPE A) 8OTTOM STIFFENER & TUSE 0-f,%- Bj WW SCALE- 3' E t'-0" SCALE: 3" o i'-0" SCALE_ 3' = T-0" L? Zq 7 N> ESQ. s v . ` >= F.:-STF71 PLAN' REVIEWED JAN 27 2W w L PANEL £KISTFNG Q STRUCTURE SEMINOL.E COUNTY -ExlsrinG , STRUCTURE ^ PLANS EXAM DOOR WIDTH I [ � w MAX- 0a0P. WIDTH L= %V-10- NOTE: MAX. DESIG14 LOAD = =35.0 P_S.F. FOR Ls12'-10" MAX_ DESIG" LOAD_= =30.3 P.S.F. FOR L- 15'-10" REFERENCE TABLE 1 ON SHEET 2 FOR SUPCRAMPOSE0 LOADS & FASTENER MAXIMUM SPACING. lf,[ iIDR ELEVATION N.T.S_ PLAN VIEW I C SCALE: 7-1l2" = 1'-D" R. ; y ` fl DRUM N, �—r—L 3ZOt< DEAD LOAD •f�c 1 3/lfi t f = -E ^..1—:01 TYPICAL PANEL - r HDUN 7ING SLOTS ` THREE 3r3'o POWERS s 2- PAWL LOT IBOLT SLEEVE. A36 ANGLE W ANCHORS AS SHOWN Q u Wr MEN. 1-S/8" EMBE[ImENT IN Y' x'3-3/L" x 1/6" THK. Q X CONCRETE OR THREE a/8"6 A36.FLAT PLATE O' (� Q STEEL SCREWS AS SHOWN W/ IJCHANNEL GUIDE O PENETRATEON IUTO HIM. 115- STEEL 2" x 2- x 3/16" x 1--Q" o � A36 ANGLE o Q QI � 3/76 � GRADE DOOR MOUKiING BRACKET DETAIL D SCALE: 1-1/2" = I' -a" cc SIDE ELEVATEON C3 " OLIDL 02-292 ADD'L. ADDITIONAL A,F•f. ABOVE FINISH FLOOR A.F.G. ABOVE FINISH GRADE A.C.T. ACOUSTICAL CELING' TILE ALT. ALTERNATE ALUM. ALUMINUM ANCH, ANCHOR APPROX. APPROXIMATE ARCH. ARCHITECT BRG. BEARINC ON. BEAM BTWN. BETWEEN BLK, BLOCK 60. BOARD ,j Ilk I- ll� I-N, I:: t, . � � n ,: >•.. as a., � +� r . «. ..,.r^ .: � xr 'a ... , .... ,,.,..r. .-» �.. 'u . .�.,. <: 'u.. r a .i;..�..:.,. ,ry a.r,'a' ,:. � .(.'... .. 'R..n'. F -. J,,...-k '.-'Y. ^.nn" '.'.' T•n';+'0`r/:.' r yr YA ., . ✓'x.�uvi�': .s. ., y., � r> _, �kL.�t,.... F��. 'd � -� .....x..�<.i ... �, s:a 3x x .x3 ,..�, ..,�.�'u d,..., .., ..,.: :S ��."'.,,,... � `�. **� ,. `bY ':s� u ' d' -�"`, ;�..�.... � �; `� 1• ?HE CONTRACTOR AID SUBCONTRACTORS SHALL COORDINATE THE WORK AND 5. ALL ONMENSIONS ON FLOOR PLANS INVICATE NOMINAL WIDTH KESS OTHERWISE P. ALL FIRE RATED CONSTRUCTION SHALL CONFORM WITH U.L. TESTED STANDARDS 21. SEAL/ CAULK PERIMETER OF RATED WALLS AND PENETRATIONS OF RATED WALLS IN p ru PHASING OF WORK DESCRIBED HEREIN WITH THE CNN.. ENGINEERING AND NOTED ON DRAWINGS. AND/OR LOCAL REQUIREMENTS ACCORDANCE WITH APPI ECABLE UL DESIGNLS, AND REQUIREMENTS OF THE AUTNCA2iTY ql� LANDSCAPE PLANS ISSUED SEPARATELY BY: HAVING JURISDICTION. _� MTC DESIGNS, INC. 6. IT SHALL BE THE RESPON5WTY OF THE CONTRACTOR TO LOCATE ALL EXISTING 13. CONTRACTOR TO PROM & INSTALL 24400C FIRE EXTINGUISHERS AS REQUIRED �" �`` u � � T # 110 RICH AVENUE UTLITIES AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR 50ALL BEAR BY LOCAL FIRE MARSHAL. COORDINATE LOCATIONS/PLACEMENTS WITH FIRE MARSHAL. 22, IT SHALL BE UNDERSTOOD THAT ALL INTENDED WORK IS SUBJECT TO REVIEW AND INTERPRETATION" DeLAND, FL 32720 ALL EXPENSES Of REPAIR OR REPLACEMENT QF UTLITIES OR OTHER PROPERTY INSTALL QUANTITY AS REQUIRED 50 AS NOT TO EXCEED 75 OF TRAVEL TO AN BY THE ADMINISTRATIVE AUTHORITY HAVING JURISDICTM IN NO CASE 514ALL WORK BE PERFORMED PH 386 740 1454 DAMAGED BY OPERATIONS IN CONJUNCTION WITH THE EXECUTION OF THE WORK. EXTINGUISHER. WITHOUT fit REVIEW AND WRITTEN AUTHORITY -0F SAID AUTHORITY. FX 366 736 7781 ALL FINAL' CONINECTIONS FROM THE BUILDING TO EXISTING UTILITIES SHALL BE BY K" 2, THE CONTRACTOR 5HALL FURNISH AND INSTALL A FULLY AUTOMATIC FIRE SPRINKLER THIS CONTRACTOR. N4. DNMEN51ONS ARE FACE TO FACE FOR MASONRY WALLS. 23. THE CONTRACTOR SHALL Be RESPONSIBLE FOR ALL FEES RELATED TO THE ISSUANCE OF PERMITS, r SYSTEM THROUGHOUT THE BULPW� THE SPRINKLER SYSTEM SHALL CONFORM TO ALL 15. METAL STUD GAUGES FOR INTERIOR PARTITIONS SHALL BE AS RECOMMENDED INSPECTIONS AND CERTIFICATES NECESSARY FOR THE EXECUTION AND COMPLETION OF THE WORK, Y LOCAL, STATE, AND NFPA CODES, AND SHALL BE DESIGNED BY A STATE Of FLORIDA 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SECURITY OF THE SITE AS AND/OR REQUIRED BY THE STUD MANUFACTURER ((RAND ALL APPLICABLE CODES) FOR AND THE OCCUPANCY OF THE WORK. REGISTERED ENGINEER. REQUIRED H THE CONTRACT DOCUMENTS. EACH SPECIFIC CONDITION, UU53. NOTED OTHERWISE, SIGNED AND SEALED SHOP DRAWINGS SHALL Be SUBMITTED TO THE FIRE MARSHAL $ ALL DEBRIS SHALL BE REMOVED FROM THE PREMISES BY THE GENERAL 24• DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS WILL GOVERN. LARGE SCALE DRAWINGS SHALL FOR APPLOCATION OF PRIOR TO INSTALLATION. CONTRACTOR. AND ALL AREAS SHALL BeLEFT IN A CLEAN CONDITION AT ALL TI'lE5 16• GENERAL CONTRACTOR SHALL COMPLY WITH ALL REQUIREMENTS OF THE SONS GOVERN OVER SMALLER SCALE DRAWINGS. CONTACT ARCHITECT/DESIGNER TO CONFIRM ALL � LOORDIN OF ALL SPRINKLER HEADS AND ALL IISTRNOCATI OF SHALL BE REPORT. OBTAIN FROM THE OWNER THE CURRENT COPY OF TINE SOILS DISCREPANCIES.R V"EW COORDINATED SO AS NOT TO INTERFERE WITH TINE LOCATION OF ANY LIGHT FIXTURE DURING CONSTRUCTION. INVESTIGATION REPORT. i ED OR H.V.A,C. WORK. ALL SPRINKLER HEAD BIGHTS SHALL BE COORDINATED WITH 25. THE ARCHITECT DESIGNER WILL NOT BE HELD RESPONSIBLE FOR WORK PERfORf1E0 NOT IN INTENDED HEIGHT OF CELING. VERIFY ALL CEILING HEIGHTS PRIOR TO INSTALLATION. q' THE GENERAL CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE / THE SAFETY Of THE OCCUPANTS. AND WORKERS AS REQUIRED BY GENERAL 17. INTERIOR FINISHES SHALL MEET OR EXCEED CLASS C AS REQUIRED BY FBC TABLE ACCORDANCE WITH THESE DOCUMENTS NOR FOR MISINTERPRETATION OF THE DRAWINGS, NOT FOR REFER TO DRAWINGS AND SPECIFICATIONS FOR REQUIREMENTS. CONDITIONS AND ALL APPLICABLE LOCAL, STATE, AND FEDERAL REGULATIONS. 704.3 AND NFPA 101 SEC. 6-5.7.1 & TABLE A-6-5.2 UNSATISFACTORY WORK BY CONTRACTOR. r THE CONNECTION FROM TAP TO RISERS INSIDE THE BUILDING MUST BE INSTALLED Y BY A M1kIIMSTATE M E MA 5 STATE CERTIFIED FIRE PROTECTION CONTRACTOR PER F.S. 633 10 DISCREPANCIES BETWEEN PORTIONS OF THE CONTRACT DOCUMENTS ARE NOT 18, ALL EXTERIOR SIDEWALK CONTROL JOINTS AND EXPANSION JOINTS TO RECEIVE POUR 26• CONFIRM ALL HORIZONTAL DMENSIONS WITH PLANS IN FIELD PRIOR TO FABRICATION/CONSTRUCTION. AND STATE FIRE MARSHAL'S INTERPRETATION SFM� q3-020 Sanford, 1I' C P r �'�n fi o n My' INTENDED. ?HE CONTRACTOR IS TO CLARIFY WITH THE ARCHITECT DESIGNER ANY GRADE SEALANT. SL2 MANUF. BY SONNEBORN OR APPROVED EQUAL. 3. THE GENERAL CONTRACTOR SHALL HELD VERIFY ALL CONDITIONS AND DIMENSIONS, DISCREPANCIES WHICH MAY OCCUR. PRIOR TO COMMENCING ANY CONSTRUCTION. 1q. -- NOTE NOT USED - 27 THE PUPURPOSEAOFC OORDINATIONIA Of THE WORK. S/DESIGN R"S THESE S IS SOLELY FOR Date: PRIOR TO COMMENCING ANY WORK. 4. ALL CONSTRUCTION SHALL COMPLY WITH APP11. 00 NOT OBSTRUCT STREETS, SIDEWALKS, ALLEYS OR OTHER RIGHT-OF-WAYS 20. ALL PENETRATIONS THRU FIRE RATED CONSTRUCTION SHALL COMPLY WITH U. & ALL ENFORCED BY AUTHORITIES HAVING JURISDICTION. WITHOUT FIRST OBTAINING PROPER PERMITS. APPLICABLE CODES &ORDINANCE. PLANSREVIEWED Ff ly G ir, SJU11FORDa BIM. BOTTOM %PQ 6ULDING B.U.R. BULT UP ROOF CLG. CEIUN6 C.M.U. CONCRETE MASONRY UNIT(S) C.T. CERAMIC TILE C.O. CLEANOUT COL. COLUMN CONC. CONCRETE CONST. CONSTRUCTION C.J. CONTROL JOINT CONT. CONTINUOUS PET. DETAIL VIA. DIAMETER DIM. DIMENSION OR. POOR ON. DOWN DS. DOWNSPOUT DWG. MAWING V.W, DRYWALL D.F. PRINKING FOUNTAIN EA. EACH E.W.C. ELECTRIC WATER COOLER ELEV. ELEVATION E0. EQUAL EQUIP. EQUIPMENT ETC. ET CETERA EXH. EXHAUST EXIST. EXISTING E.J. EXPANSION JOINT EXT. EXTERIOR F.R.P. FIBERGLASS REINFORCED PANEL fIN. FINISH F.E. FIRE EXTINGUISHER. FLUOR. FLUORESCENT F.D. FLOOR DRAIN FLR. FLOOR FT. FOOT, FEET FIG, FOOTING F.Y. FIELD VERIFY GALV. GALVANIZED INT. INTERIOR MAX. MAXIMUM NO. NUMBER PM. PLUMBING S.F SQUARE FEET, FOOTAGE TEL. TELEPHONE GA. GAUGE JT. JOINT MECR MECHANICAL PLYWR PLYWOOD SCHED• SCHEDULE TEMP. TEMPERED G.C. GENERAL CONTRACTOR MTL. METAL O.C. ON CENTER PROP. PROPERTY SLT, SEALANT THRSS. THRESHOLD GR. GRADE K.O. KNOCK OUT MIEZZ. MEZZANINE OR OVERHEAD SEC, SECTION T,P.D, TOILET PAPER DISPENSER GYP, GYPSUM MIN. MINIMUM OPG. OPENING Q.T• QUARRY TILE SUM. SIMILAR T.&C. TONCUE AND GROOVE LAM, LAMINATED MISC. MISCELLANEOUS OPP. OPPOSITE SL. SLOPE T.&B. TOP AND BOTTOM HOW. HARDWARE LAY. LAVATORY MLDG. MOULDING O.U. OUTSIDE DIAMETER R RADIUS SPEC. SPECIFICATION T.O.F. TOP OF FOOTING HGT. HEIGHT LB. POUND M.R. MOBTURE RESISTANT W. REFERENCE 30. SEIIARE T.O. HAS. TOP OF MASONRY H.M. HOLLOW METAL L.H. LEFT HAND MTG, MOUNTING P.T. PRESSURE TREATED REINF, REINFORCED, REINFORCING S.S. STAINLESS STEEL T.O.S. TOP OF STEEL H.P. HIGH POINT L.P. LOW POINT MULL. MULLION PIP. PAINTEV REOD. REQUIRED STD. STANDARD I. TREAD HORIZ, HORIZONTAL PNL. PANEL. OR PANELING REV. REVERSE STL. STEEL TYR TYPICAL MFR. MANUFACTURER NOM. NOMINAL, PART, PARTITION R.H. RIGHT HAND STRUCT. STRUCTURAL INCAN. INCANVESCENT HAS. MASONRY N. NORTH P.H. PHYSICALLY HANDICAPPED RM. ROOM SUSP, SUSPENDED UNFIN. UNFINISHED I.D. INSIDE DIAMETER M.O, MASONRY OPENING N.I.C. NOT IN CONTRACT PLAS. PLASTER R.O. ROUGH OPENING SW. S'MTCH U.O.N. UNLESS OTHERWISE NOTED M. INSULATION MAIL. MATERIAL N.T.S. NOT TO SCALE PLAN. PLASTIC LAMINATE R.T.U. ROOF TOP UNIT SYS, SYSTEM VERT. VERTICAL VEST. VESTIBULE V.C.T. VINYL COMPOSITION TLE W.C. WATER CLOSET W.N. WATER HEATER W.P. WORK POW WP. WATERPROOF W.R. WATER RESISTANT W.W.M. WELDED WIRE MESH W/ WITH W/0 WITHOUT WD. WOOV v rD m i cv u) n.� 0 C3 W CD a Lm -j G CD c_ P0 Q U, Py U 0 0 v� u> n ro n APPLICABLE CODE-S 1. CODE REQUIREMENTS: IT IS THE INTENT THAT ALL WORK SHALL CONFORM TO THE ADOPTED City of Sanford, Florida CODES, STANDARDS AND RULES OF THE ADMINISTRATIVE AUTHORITY HAVING JURISDICTION. 1. THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO THE PREPARATION OF HIS BID AND THOROUGHLY FAMILIARIZE HIMSELF WITH THE CONDITIONS OF THE CONSTRUCTION AREA FIRE SEPARATIONS 2. ALL WORK SHALL CONFORM WITH DRAWINGS AND SPECIFICATIONS IN ACCORDANCE WITH THE AND THE WORK REQUIRED TO PERFORM THE WORK OF THIS CONTRACT. OBTAIN DIMENSIONS FLORIDA BUILDING CODE 2001 EDITION (USED FOR BUILDING, PLUMBING, REQUIREMENTS OF ALL THE FOLLOWING WHERE APPLICABLE: BY CALCULATION; DO NOT SCALE THE DRAWINGS. IF DIMENSIONS ARE IN QUESTION, THE MECHANICAL, FUEL & CAS; FLORIDA ACCESSIBILITY FOR BUILDING CONSTRUCTION, CONTRACTOR SHALL REQUEST CLARIFICATION FROM THE ARCHITECT PRIOR TO CONTINUING STATE: OF FLORIDA MODEL ENERGY EFFICIENCY). WITH 2O03 REVISIONS NONE REQUIRED (A) GOVERNING MUNICIPAL AND REGULATORY AGENCIES CONSTRUCTION OF THE AREA IN QUESTION. FLORIDA FIRE PREVENTION CODE 2001 EDITION (B) LOCAL, STATE AND FEDERAL BODIES 2. UNLESS OTHERWISE NOTED OR DETAILED, PIPE CHASE WALLS WITH A THICKNESS GREATER (C) 2001 FLORIDA BUILDING CODE THAN 4" SHALL BE CONSTRUCTED OF 2-1/2" METAL STUDS WITH ONE LAYER 5/8" GYPSUM BOARD EACH SIDE OF CHASE WALL. PROVIDE METAL OR GYPSUM BOARD CROSS BRACES AS NFPA FORE PREVENTION CODE 2000 EDITION REQUIRED TO ADEQUATELY BRACE THE WALL AND TO MAINTAIN THE RATING OF THE .00CUPANT LOAD: 3. THE GENERAL CONTRACTOR SHALL COMPLY WITH ALL THE REQUIREMENTS OF THE SOILS PARTITION. HOLD CHASE WALLS TO MINIMUM DIMENSIONS. NFPA 1012000 EDITION REPORT, OBTAIN FROM THE OWNER THE CURRENT COPY OF THE SOILS INVESTIGATION OCCUPANCY PER 2001 FLORIDA BUILDING CODE, TABLE 1003.1 REPORT. 3. VERTICAL PIPING LOCATED WITHIN THE STUD SPACE OF PARTITIONS SHALL BE FULLY NATIONAL ELECTRIC CODE 1999 EDITION OCCUPANCY GROUP B: 1 PERSON PER 100 S.F. CROSS = 13,420 SF 1100 w 14 ENCLOSED WITH A FULL THICKNESS OF GYPSUM BOARD ON EACH SIDE OF THE STUD. OCCUPANTS 4. ALL DEBRIS SHALL BE REMOVED FROM THE PREMISES BY THE GENERAL CONTRACTOR AND PROVIDE 6" STUDS WHERE REQUIRED TO CONCEAL PIPING AND OTHER ITEMS OCCURRING ALL AREAS SHALT. BE LEFT IN A CLEAN CONDITION AT ALL TIMES DURING CONSTRUCTION. WITHIN PARTITIONS. CLASSIFICATIONOCCUPANCY ® 5. IT IS UNDERSTOOD THAT ALL INTENDED WORK IS SUBJECT TO REVIEW AND INTERPRETATION 4. RECESSES FOR ITEMS IN EXCESS OF 1.6 SQ. INCHES, SUCH AS ELECTRICAL PANELS, FIRE FLORIDA BUILDING CODE: BUSINESS - GROUP B, SECTION 305 BY THE ADMINISTRATIVE AUTHORITY HAVING JURISDICTION. IN NO CASE SHALL WORK BE EXTINGUISHER CABINETS, ETC., LOCATED IN RATED PARTITIONS SHALL BE FACED WITH I" REQUIREMENTS: PERFORMED WITHOUT THE REVIEW AND WRITTEN APPROVAL OF SAID AUTHORITY. GYPSUM BOARD TO CREATE A FIVE -SIDED ENCLOSURE REQUIRED TO MAINTAIN THE RATING OF THE PARTITION IN WHICH THE ITEM OCCURS. BUILDINGOCCUPANCY GROUP B - BUSINESS: 6. ALL TRADES .SHALL BE RESPONSIBLE FOR ALL FEES RELATED TO THE ISSUE OF TRADE -SPECIFIC PERMITS, INSPECTIONS AND CERTIFICATES NECESSARY FOR THE 5, ELECTRICAL DEVICES WHICH OCCUR IN RATED PARTITIONS SHALL BE LOCATED 80 THAT ALLOWED, PER 2001 FLORIDA BUILDING CODE, TABLE 500 : 2 EXITS REQUIRED PER FLOOR PER 104.2.2 (BASED ON OCCUPANT LOAD FOR 1-500 EXECUTION AND COMPLETION OF THE WORK, AND THE OCCUPANCY OF THE WORK. BACKBOXES WITHIN A SINGLE STUD CAVITY SHALL NOT EXCEED A TOTAL OF 16 SQUARE OCCUPANTS) INCHES IN AREA OR EXCEED A TOTAL OF 100 SQUARE INCHES IN ANY 100 SQUARE FEET OF OCCUPANCY GROUP B: 51,000 S.F., 1-STORY 7. EXISTING CONDITIONS: THE CONTRACTOR SHAD. VERIFY EXISTING CONDITIONS AND WALL AREA. BOXES LOCATED ON OPPOSITE SIDES OF WALLS OR PARTITIONS SHALL BE 300 FEET MAXIMUM TRAVEL DISTANCE TO EXIT (SPRINKLERED) PER FBC FIELD -COORDINATE THE CORRECTIVE ACTION, SEPARATED BY A MIN. HORN, DISTANCE OF 24". WHERE THIS REQUIREMENT CANNOT BE MET, 100% INCREASE ALLOWED WITH 30' HORIZONTAL FROM STREETS or UNLIMITED BACKBOXES IN EXCESS OF THE ALLOWED MAXIMUM SHALL BE BACKED WITH GYPSUM BOARD INCREASE WITH SPRINKLERS AND 60' OF OPEN SPACE ALL SIDES 50 FEET MAXIMUM DEAD END CORRIDOR (SPRINKLERED) 8. AS REQUIRED. THE GENERAL CONTRACTOR SHALL NOTIFY THE ARCHITECT/DESIGNER OF ALL TO CREATE A FIVE -SIDED ENCLOSURE, CONFLICTS AND DISCREPANCIES THAT AFFECT THE WORK PRIOR TO PROCEEDING WITH SAID OFFICE AREA 1,420 S.F. 75 FEET MAXIMUM COMMON PATH OF TRAVEL (SPRINKLERED) WORK. 6. JOINTS WHICH OCCUR IN RATED PARTITIONS SHALL BE STAGGERED A MINIMUM OF ONE STUD DETAILING AREA 12,000 S.F. SPACE OR 24" BOTH HORIZONTALLY & 12" VERTICALLY. WHERE OPENINGS ARE MADE IN MINIMUM EXIT DOOR CLEAR WIDTH ® 32" 9. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS WILL GOVERN, LARGE-SCALE DRAWINGS EXISTING RATED PARTITIONS, OR WHERE OPENINGS IN EXISTING PARTITIONS ARE CLOSERS, SHALL GOVERN OVER SMALLER -SCALED DRAWINGS. CONTACT ARCHITECT/DESIGNER TO THE EXISIT NG GYPSUM BOARD BOARD MAY BE REMOVED ON ONE SIDE OF THE PARTITIONS TOTAL BUILDING AREA 13,420 S.F. MINIMUM AISLE = 44" CONFIRM ALL DISCREPANCIES. BACK TO THE NEXT STUD TO ASSURE THE PROPER STAGGERING OF THE JOINTS. .2" EGRESS WIDTH PER PERSON (HORIZONTAL EGRESS) 10. CONFIRM ALL HORIZONTAL DIMENSIONS WITH PLANS AND IN FIELD PRIOR TO FABRICATION 7. DIMENSIONS ARE FACE TO FACE OF MASONRY WALLS AND TO FINISH FACE OF STUD BUILDING TYPEAND/OR CONSTRUCTION. PARTITIONS. .2" PER 14 PERSONS = 2.8" REQUIRED TOTAL EXIT WIDTH 11. THE ARCHITECT/DESIGNER SHALL NOT BE HELD RESPONSIBLE FOR WORK PERFORMED NOT 8. METAL STUD GUAGES FOR INTERIOR PARTITIONS SHALL BE AS RECOMMENDED BY AND/OR SPRINKLERED D FLORIDA }BUILDING CODE, CHAPTER 6 TYPE FOUR (IV), UNPROTECTED, SEE LIFE SAFETY PLANS FOR ACTUAL EXIT WIDTHS IN ACCORDANCE WITH THESE DOCUMENTS NOR FOR MISINTERPRETATION OF THE DRAWINGS, REQUIRED BY THE STUD MANUFACTURER FOR EACH SPECIFIC CONDITION, SPR NOR FOR UNSATISFACTORY WORK BY CONTRACTOR. MATERIALS: CMU / BRICK EXTERIOR WALLS, STEEL TRUSSES, METAL ROOF, 12. ALL ELECTRICAL AND MECHANICAL INFORMATION CONTAINED IN THESE DRAWINGS IS SOLELY METAL STUD INTERIOR WALLS FINISHESINTERIOR FOR THE PURPOSE OF COORDINATION OF THE ARCHITECT/DESIGNER'S WORK. FIRE RESISTANCE RATINGS FROM TABLE 600 FIRE PROTECTION REQUIREMENTS PER FBC TABLE 600 : INTERIOR WALL FINISHES TO BE CLASS A OR B IN EXITS OR ENCLOSED CORRIDORS, 13, ALL CONSTRUCTION SHALL COMPLY WITH APPLICABLE LAWS RELATING TO ACCESSIBILITY FOR INTERIOR BEARING 609.2.3. (ANY MATERIAL) THE DISABLED. FLORIDA STATUTES, CHAPTER 553, PART V, FLORIDA ACCESSIBILITY CODE. COLUMNS NO (SUPPORTING ROOF ONLY) FLOOR FINISHES SHALL BE CLASS I OR 11 IN EXITS AND CORRIDORS. BEAMS, GIRDERS, TRUSSES NC (SUPPORT1N(3 ROOF ONLY) ROOF/ CEILING; NC VESTIBULE FINISHES SHALL NOT EXCEED CLASS B EXTERIOR BEARING WALLS RATING / % PERMITTED OPENINGS NORTH NC (NL%) WHERE MORE THAN ONE MEANS OF EGRESS IS REQUIRED FROM ANY ACCESSIBLE SPACE SOUTH NC (NL%) THEN AT LEAST TWO ACCESSIBLE MEANS OF EGRESS MUST BE PROVIDED. (SECTION 1004.3.1) EAST NC (NL%) DOORS SHALL SWING IN THE DIRECTION OF EGRESS TRAVEL WHEN SERVING 50 OR MORE WEST NC (NL%) OCCUPANTS (SECTION 1012.1.2) MEANS OF EGRESS SHALL BE ILLUMINATED TO AT LEAST ONE EXTERIOR NON -BEARING WALLS RATING / % PERMITTED OPENINGS FOOT-CANDLE, MEASURED AT THE FLOOR. (SECTIONS 1016.1) NORTH NC (NL%) EAST NC (NL%) EMERGENCY LIGHTING SHALL BE PROVIDED FOR A PERIOD OF 1 1/2 HOURS IN THE EVENT OF WEST NC (NL%) NORMAL LIGHT FAILURE. INITIAL ILLUMINATION MUST BE AN AVERAGE OF AT LEAST ONE -FOOT CANDLE & A MINIMUM AT ANY POINT OF .2 FOOT-CANDLE ALONG THE PATH OF EGRESS AT BUILDING HEIGHT FLOOR LEVEL. (SECTIONS 1016.2,2 & 3) 5 STORY MAXIMUM ALLOWABLE HEIGHT PER FBC: TABLE 500 MEANS OF EGRESS SHALL BE MARKED BY SIGNS, EXCEPT WHERE A MAIN ENTRANCE SERVES AS AN EXIT & IS VISIBLE TO THE OCCUPANTS. (SECTIONS 1016.3.1 & 3.3.3) DETAIL NUMBER ACTUAL HEIGHT` = 22'-0' — — — — - — -- — LINES OF CEILING CHANGES at SOFFITS, OVERHANGS, ETC. 4 THRU-BUILDING SECTION Y-4 DETAL WILL APPEAR PLUMBING FIXTURE REQUIREMENTS. 6N THIS PANE ALI COLUMN GRID REFERENCE NUMBER or LETTER FULL WALL SECTION OCCUPANTS LOAD PER TABLE 403.1 (2001 FBC PLUMBING CODE) GROUP B - BUSINESS OCCUPANCY 11-IOL PARTIAL SECTION DOOR NUMBER WATER LAVATORIES SHOWERS DRINKING OTHER ®4 1 CLOSETS FOUNTAINS DETAIL or ENLARGED PLAN REFERENCE 4 AS 2 INTERIOR ELEVATION TAG REQUIRED FIXTURES: �' S (OCC -1 OCCUPANT FOR 100 S.F.) d 14 1 PER 50 1 PER 80 NONE 1 PER 100 SERVICE OCCUPANTS SINK M— -- PARTITION TYPE ( SEE SCHEDULE THIS SHEET) CEILING HEIf�HT� REVISION CLOUD & REVISION NUMBER � CEILING NOTE ( TYPE, REFERENCE, HEIGHT) � NEW FIXTURES REQUIRED 1 1 NONE 1 '1 SERVICE SINK 2 WCs 1 KITCHEN SINK T�CEIL N MATERIAL 2 URINALS TOTAL PROVIDED 4 NONE 1 1 SERVICE SINK or TYPE NOTE: AT LEAST ONE FIXTURE OF EACH TYPE SHALL BE HANDICAP ACCESSIBLE I DASHED LINE ARROWS INDICATE INDICATES ACTUAL DIRECTION OF TRAVEL TO EGRESS TRAVEL PATH EXIT ALONG EGRESS PATH I - - - - - - - - - - - - - I NORTH I 04 CD CD ZE: w cn ru (D CD U) CD to (n 0) rt c-n CD U1 w PU LO C-) m M AM" ARCHITECTUIRAL DYNAMICS, LLC 2816 PICKFAIR STREET ORLANDO, FIL 32803-6827 PHONE: 407 897 5461 FAX: 407 896 3501 EMAIL: archsolve@aol.com FL LIC NO: M26000600 uk p, CONSTRUC"ON CO. GENERAL CONTRACTORS 790 MONROE RD. SANFORD, FL 32771 PH 407 323 1150 FX 407 323 9304 o Mafling Address- P.O. BOX 471366 LAKE MONROE, FL 32747-1366 �" � =o � ' ; �° !' '� ! °� #I# !! � (( � € t� ! 4� r# ` � � ! 'FF !I !! tF � � ! i� • • ...................... ............ Q 0001� 3 PROVIDE 4" DEEP CONCRETE PAD AIR COMPRESSOR PROVIDED BY OWNER 27'-6" 27'-6" 20'-0" 20'-0" 27'-6' 27'-6" —Oil —of# Oil 0 1 0, 0 —0 6' _0' _0" 6 0"' 6-01' -0 0.,L oil 1;3 0, 0,- --ol -0111 i0l T T T T T T T T iol of T T T y T Of -0 T OT"' f f, T OT"' T T T 0 T"' -------- I -------- -- --- ----- -- ------ 57 T I I. 114 It I I I 111111&111 t 1.111110 H Hil I I I I 10 111111 11-HUILIJ H I FLIJBIJIMIL111K 11111ml it] I III] LLIKI 11111LILI -------- anuuUUML� ill _wj.1 is-MUMILI III III III I I to IjLuj"u= n I I I I I LK Q> EXHAUS rF 'N FAN (71fo\OF 4) \ I i -UA f Q) 1\6 N 1k V A\ /2 Q) Q) 0 \ k F n1l J C= 0 LARD, FE Q) BOLLARD, TYPICAL SEE 6/S,2 NA3.2 UC D LINg AREA ETAI Q) Q) IJ) W Q) ODA 0 0 A2 171 fLOOR STIPING Vj lZo 0 01 Q> A —ul /X/, lZ> WASHER ---UF DR�jfR Q)i 0 r -------- -------- --- T + MiWH T U III Hell] 11 11LIKII411 I 111ILKIIIIIII41i - -------- Ulk M9 4� 0 6-4" 1-0 to i-0 z + 0- '-0`3 —0`3' —Oil —Oil —013 11 ov 6'-4" ��_ 40. —0 1-0-p'-0., —0., 2- 10.1 1 -7, �I 'GH A2 PANEL LIGHT / 01 0* oZ) LM SEE SHEET A2.2 FOR ENLARGED FLOOR PLANS I L 27'-6" 25'-0" 12'-611 10,_011 10,_011 25-0' 27'-6" — — — — — — — — — — — — — -- 5 1'-4" 147-4" 151'-411 3A 4A 4 4B 5A 6 150'-00 Cn FLOOR PLAN SCALE 1/8" 1'-0" NORTH F—o 1 0 '_01 _011 I-0i ------- ------- -- K2TMTMTpffnTTn A Ir 0001� 3 PROVIDE 4" DEEP CONCRETE PAD AIR COMPRESSOR PROVIDED BY OWNER 27'-6" 27'-6" 20'-0" 20'-0" 27'-6' 27'-6" —Oil —of# Oil 0 1 0, 0 —0 6' _0' _0" 6 0"' 6-01' -0 0.,L oil 1;3 0, 0,- --ol -0111 i0l T T T T T T T T iol of T T T y T Of -0 T OT"' f f, T OT"' T T T 0 T"' -------- I -------- -- --- ----- -- ------ 57 T I I. 114 It I I I 111111&111 t 1.111110 H Hil I I I I 10 111111 11-HUILIJ H I FLIJBIJIMIL111K 11111ml it] I III] LLIKI 11111LILI -------- anuuUUML� ill _wj.1 is-MUMILI III III III I I to IjLuj"u= n I I I I I LK Q> EXHAUS rF 'N FAN (71fo\OF 4) \ I i -UA f Q) 1\6 N 1k V A\ /2 Q) Q) 0 \ k F n1l J C= 0 LARD, FE Q) BOLLARD, TYPICAL SEE 6/S,2 NA3.2 UC D LINg AREA ETAI Q) Q) IJ) W Q) ODA 0 0 A2 171 fLOOR STIPING Vj lZo 0 01 Q> A —ul /X/, lZ> WASHER ---UF DR�jfR Q)i 0 r -------- -------- --- T + MiWH T U III Hell] 11 11LIKII411 I 111ILKIIIIIII41i - -------- Ulk M9 4� 0 6-4" 1-0 to i-0 z + 0- '-0`3 —0`3' —Oil —Oil —013 11 ov 6'-4" ��_ 40. —0 1-0-p'-0., —0., 2- 10.1 1 -7, �I 'GH A2 PANEL LIGHT / 01 0* oZ) LM SEE SHEET A2.2 FOR ENLARGED FLOOR PLANS I L 27'-6" 25'-0" 12'-611 10,_011 10,_011 25-0' 27'-6" — — — — — — — — — — — — — -- 5 1'-4" 147-4" 151'-411 3A 4A 4 4B 5A 6 150'-00 Cn FLOOR PLAN SCALE 1/8" 1'-0" NORTH F—o 1 0 '_01 _011 I-0i ------- ------- -- K2TMTMTpffnTTn A Ir W, rn co C-) 0.) O R-) ry rn LO ,Ln ru CD ru O O C7- I r)%Al OnINIT nE' E'A%/C LJC'tr'L-IT PLUMI VENT PLUMBING VENT Ny ROOF PLAN SCALE 1/8" = 1'-0" NORTH I C-) 0 2 0 SCALE 1/4" = l'-O" NORTH 2 2 ON R- l"ns1.11 El"I'll, WALL ASSEMBLY TYPES MARK ASSEMBLY DESCMION THK. HEIGiT REMARKS 3-50 METAL STUDS @ 16® O.C. WITH ONE (1) LAYER 5/8'GYPSUM WALLBOARD ON EACH SIDE WISOUND ATTENUATION BLANKETS 4-7/8 TO UNDERSIDE OF CEILING DECK MARK ASSEMBLY DESCRVrX)N Tw Muff REMARKS IFZ L= 3-518- METAL STUDS @ 16- O.C. WITH ONE (i) LAYER 51W GYPSUM WALLBOARD ON EACH SIDE WISOUND ATTENUATION BLANKETS 4-7/8" O WABOVE FINISHED TCEILING MARK ASSEMBLY DESWMN THK, HOW REMARKS 6'METAL STUDS @ 16'O.C. WITH ONE (1) LAYER 5/8" GYPSUM WALLBOARD ON EACH SIDE WISOUND ATTENUATION BLANKETS 4-718" TO 6ABOVE FINISHED CEILING PLUMBING CHASE 3-518" METAL STUD PARTITIOV--, 6" METAL STUD PARTITION 8'CMU WALL BRICK VENEER O co ..... .... . �Mj WE noe.q�asw MA"TEMAL LEGEND MAMRIAL or M 1 METAL BUILDING 'R' PANELS 2 METAL PANEL BACKSHEETING 3 PLEXIGLASS WALL LIGHTS 4 FOAM CORNICE WITH METAL COPING 5 LOK—SEAM METAL ROOFING 6 ACCENT, BRICK OR PRECAST ELEMENT 7 NOT USED 8 FOUNDATION PROFILE 9 BRICK VENEER, RUNNING BOND 10 BRICK ROWLOCK SILL 11 BRICK SOLDIER COURSE HEADER 12 ALUMINUM STOREFRONT 13 NOT USED 14 8" PAINTED CMU, STRUCK JOINTS 15 STANDARD 'R' PANEL ROOFING, GALVALUME FINISH 16 CUTTER & DOWNSPOUT 17 OVERHEAD METAL DOOR 18 BOLLARD 19 WALL—PAK LIGHTING 20 METAL DOOR, PAINTED 211 16" X 16" OUTDOOR AIR LOUVER 22 16" X 16" EXHAUST LOUVE 23 EXHAUST FAN LOUVER — 36" X 36" 24 INTAKE LOUVER — 4'-8" W X .4'—O" H 13D-6" EAVE HEIGHT o'—o" _ FIN FLOOR llWK 1 R CILC V A I IVN ins /"u " Ail .,,, d-..� _S(lI I i 9:I PV A TInKI ELEVATION TWEST SCALE 1/8" = 1'-0" 22'-0" T.O. PARAPET CMU ~� 6•_0„ 6'-0„ 6'-0„ 12'-0" 20'—OD, T.O. PARAPET CMtJ � CMU EXTENTS 19 � U , CH 7 I C V A I IVN SCALE 1/8" 16'-10" SAVE HEIGHT 13'-0" _ TOP OF WINDOW T.O. MASONRY 00'-0" FIN FLR 22'-0" _ T.O. PARAPET 20'-0" _ T.O. PARAPET 13'-6" _ EAAVE HEIGHT 8,-0" T.O.M. 0'---0" FIN FLR 1,39_6" EAVE HEIGHT O9_O>D FIN FLOOR _ g- RM ARCHITECTURAL DYNAMICS, ORLANDO, 32803-6827 PHONE: f.. i' 897 t. • t FAX: 407 its 3501 archsolve@aol.com FL LIC NO. • i 0060 0011STRUCII'lloff CO. GENERAL j CONTRACTORS 90 MONROE _, PH 41 FX 407 ,, 1, .+fi-. P.O. :1, t1 LAKE ♦ r, • t drodd@mckeeconstruedonco.com r.•` t art rig► r► r. r , bill; EXTERIOR ;Or ELEVATIONS lI li � I �Ir f�'��'Iliiiilll"' ' 1111l: !I• 3" VINYL REINFORCED METAL BUILDING INSULATION VARIES STANDARD "R" WALL PANELS W/ "SIGNATURE 200" FINISH 3" VINYL REINFORCED METAL BUILDING INSULATION 8" GIRTS REFER TO METAL BUILDING DRAWINGS CHANNEL TOP OF MASONRY. 8'-0" (1) #5 CONT. AT LINTEL 8" HOOK AT LINTEL VERTICAL REINFORCING: (1) #5 IN SOLID GROUTED CELL — SEE FLOOR PLAN FOR LOCATIONS HORIZONTAL REINFORCING 0 16" OC 8" CMU FOOTING TO LINTEL REBAR TIE; MINIMUM 25" OVERLAP FINISH FLOOR 0'-0" (REFERENCE) 6—MIL VISQUEEN — COLUMN PAD BEYOND VAPOR BARRIER SEE FOUNDATION PLAN AND DETAILS J t SCALE: 3/4" = 1'-0" STANDARD 'R' PANEL 26 GA' 1nr f At \/RI 1 IA Jr r1All Cl PURLIP BY PE 3" VIN METAL HIGH I 16'-1 CHANN STAND W/ "� 3" VIN METAL 8" GIR REFER CHANN Ah TOP 0 8'-0" (1) #5 8" HO, VERTIC SOLID PLAN 1 8" CN STRUC HORIZC 0 16" FOOTIN MINIMU -0FINISI —0'_0" SEE C COLUMN! PAD BEYOND 6—MIL VISQUEEN SEE FOUNDATION PLAN AND DETAILS VAPOR BARRIER WALL SE%C-h.Tl%0"'N WAREHO"U"S"of (NORTH) SCALE: 3/4" = 1'—O" STANDARD 'R' PANEL 26 GAUGE, GALVALUME FINISH PURLINS, SIZE & SPACING BY PEMB MFR --- ---- 3" VINYL REINFORCED 12 METAL BUILDING INSULATION -1 1/2 LOW POINT OF ROOF 13'-6" ALUM GUTTER & DOWNSPOUTS 1 CHANNEL STANDARD 'T WALL PANELS W/ "SIGNATURE 200" FINISH 3" VINYL REINFORCED METAL BUILDING INSULATION 8" GIRTS REFER TO METAL BUILDING DRAWINGS TOP OF MASONRY 8'— (1) #5 CONT. AT LINTEL I 8" HOOK AT LINTEL I VERTICAL REINFORCING: (1) #5 IN SOLID GROUTED CELL — SEE FLOOR PLAN FOR LOCATIONS I 8" CMU, PAINTED W/ STRUCK JOINTS I RAL COLUMN I HORIZONTAL REINFORCING I 0 16" OC �I 5" CONCRETE SLAB 0 WAREHOUSE _ FOOTING TO LINTEL REBAR TIE; MINIMUM 25" OVERLAP II_ FINISH FLOOR q • a ." A : • ° 4 . a 0'-0" (REFERENCE) I 'C . 4 4 _rl 11=1 I M I-=1 11 I=1 11= I I f ICI 11=1 { I I 167 �� .. � �` � . • � ° .. � ... 1�1=1 I ICI I 1=1 I =-1 f 1- SEE CIVIL 6—MIL VISQUEEN COLUMN PAD BEYOND VAPOR BARRIER SEE FOUNDATION PLAN AND DETAILS r y, SCALE: 3/4" = 1'-0" r ti- s s -o n CD cu ro c j ry CD w CD A w w a CD UD ru 0 0 w n s H a r— n M n cn GALVANIZED COPING �-- -- -,-- 22'-0" -0- TOP OF PARAPET FRAMING PRECAST CONCRETE TRIM #M-53 ULTRALITE BY GLADSTONE 4" PARTITION BLOCK BEHIND TRIM 181_2" + HIGH POINT OF ROOF WEEP HOLES WITH COTTON ROPE @ 16" OC METAL BRICK ANGLE FLASHING LOK-SEAM METAL ROOFING OVER 5/8" PLYWOOD SHEATHING 12 OVER LT GAUGE METAL FRAMING 6 BY PEMB MFR ----N B.O. FRAMING 9' — 4" STUCCO ON RIB LATH OVER ON LT GAUGE METAL STUD FRAMING BY PEMB MFR (HORIZONTAL SURFACES) GIRT - LOCATE PER PEMB MFR — BRICK VENEER RUNNING BOND W/ BRICK TIES ® 16" QC HORIZONTALLY & VERTICALLY OVER METAL PANELS PEMB W/ 3" METAL BUILDING INSULATION 1 " MIN AIR SPACE COTTON ROPE WEEPS AT 16" OC — SEE CIVIL FINISHED FIRST FLOOR 0'-0" (ASSUMED) FLASHING; GROUT SOLID BELOW— (1) #5 FOOTING TO LINTEL REBAR TIE; MINIMUM 25" OVERLAP ----- 5'-0 Il ATTACHMENT BY PEMB MFR SCALE: 3/4" = 1 ' -0" ll 26 GAUGE GALV. BACK -SHEETING FLASHING 'R' PANEL METAL ROOFING SLOPE 1/2" / FOOT PURLINS, SIZE & SPACING BY PEMB MFR 3" VINYL REINFORCED METAL BUILDING INSULATION PLAN/SECTION DETAIL: DOVE -TAIL ANCHOR W/ SELF -TAPPING SCREW! INTO STUDS AT 16" OC HORIZ AND VERTICALLY STEEL COLUMN BEYOND 6" BATT INSULATION LAY -IN ACOUSTICAL TILE 5/8" GYPSUM BOARD ON 1-5/8" METAL STUDS W/ 1" RIGID INSULATION IN BETWEEN (EXTEND GYPSUM BOARD 6" ABOVE FINISH CEILING) --�----- STRUCTURAL COLUMN BEYOND REFER TO METAL BUILDING DRAWINGS BOX OUT COLUMN - SEE PLAN FOR EXTENTS 4" CONCRETE SLAB GALVANIZED COPING 20'-0" TOP OF PARAPET FRAMING PRECAST CONCRETE TRIM #M-53 ULTRALITE BY GLADSTONE 4" PARTITION BLOCK BEHIND TRIM 18'-2" + HIGH POINT OF ROOF CONTRAST BRICK COLOR DOUBLE SOLDIER COURSE -4n GIRT - LOCATE PER PEMB MFR PEMB BRICK VENEER RUNNING BOND W/ BRICK TIES 0 16" OC HORIZONTALLY & VERTICALLY OVER METAL PANELS — 3" VINYL METAL BUILDING INSULATION 1 " MIN AIR COTTON ROPE WEEPS AT 16" OC — SEE CIVIL r' FINISHED FIRST FLOOR IV 0'-0" (ASSUMED) FLASHING; GROUT SOLID BELOW - SCALE: 3/4" = 1'-0" 26 GAUGE GALV. BACK -SHEETING FLASHING PURLINS, SIZE & SPACING BY PEMB MFR 3" VINYL REINFORCED METAL BUILDING INSULATION STEEL COLUMN BEYOND 6" BATT INSULATION LAY -IN ACOUSTICAL TILE 5/8" GYPSUM BOARD ON 1-5/8" METAL STUDS W/ 1" RIGID INSULATION IN BET`A!EEN. (EXTEND GYPSUM BOARD 6" ABOVE FINISH CEILING) STRUCTURAL COLUMN BEYOND REFER TO METAL BUILDING DRAWINGS BOX OUT COLUMN - SEE PLAN I FOR EXTENTS " 4 CONCRETE SLAB IF Rr __j COLUMN PAD BEYOND 6-MIL VISQUEEN SEE FOUNDATION PLAN AND DETAILS VAPOR BARRIER 10,, SCALE: 3/4" = 1'--0" IlrIl 2 � III In In F�. ♦fir :� .i 1 �.,%w.�. c� CD CD j ID U) zr CD n CD O .G .n CD Ul ti 0 Q W Lo ru CD 171 W a� z r 0 n r- r✓ 7-_6e, CUP HOLDER TA4 rA6 60" r ti 90 r 60" DIA I TURNING 1 I RADIUSZNJ I r p TA9 r--F I I TA4 tv 130" 1 ° r I I I TA8 icy I I 48» 60" 1 TAi 1_�W TA2 I 50' ._. m m SCALE: 3/8" = 1'-0" SCALE: 3/8" = 1'-0" DRINKIN(11 i FOUNTAIN TA3 LTA11 TA51 1211 4 211 r T 60'� I 1r- TA21 i \r LTA TURNING -� - - - - - RADIUS o TA8 i 66 �30" CERAMIC -e-si r WAINSCOT TOILET PA DISPENSEI GRAB BAR SANITARY DISPOSAL 3 I SCALE: 3/8" = 1'-0" t S, SCALE. 3/8" = V--0" TOILET ACCESSORIES ® (DESIGN BASIS ONLY: OWNER MAY SELECT FIXTURES) NUMBER: DESCRIPTION: MOUNTING HEIGHT PROVIDED BY: TA1 SURFACE -MOUNTED TOILET PAPER HOLDER, MANF, BOBRICK MODEL #B-66997 19" A.F.F TO CENTER OF HOLDER BY GC TA2 GRAB BAR 36" LENGTH MANF. BOBRICK MODEL #B-6806 SERIES 33" A.F.F. TO TOP OF BAR BY CC TA3 GRAB BAR 42" LENGTH, MANF. BOBRICK MODEL #B-6806 SERIES 33" A.F.F. TO TOP OF BAR BY GC TA4 SURFACE -MOUNTED PAPER TOWEL DISPENSER/WASTE RECEPTACLE MANF, BOBRICK MODEL #13-394 48" A.F.F. MAX. TO TOWEL HGT, BY GC TA5 SURFACE -MOUNTED SANITARY NAPKIN DISPOSAL BOBRICK MODEL #13-270 24" TOP OF UNIT BY GC TA6 MIRROR, 36" HIGH X WIDTH OF COUNTER 40" TO BOTTOM OF MIRROR BY GC TA7 SOAP DISPENSERS 42" BY GC TA8 24" X 36" MIRROR 40" TO BOTTOM OF MIRROR BY GC TA9 URINAL SCREEN BY GC TA10 TOILET PARTITION BY GC 3,-011 TOILET PAPER DISPENSER 0 PAPER TOWEL MIRROR TOWEL HOOK DISPENSER TOILET SEAT SOAP GRAB BAR COVER SANITARY SOAP DISH DISPENSER DISPENSER NAPKIN F DISPOSAL ca _ to FINISH FLOOR Ilk 0Ah ni�nrnncn IsdCITAI i n-ri11.1. SCALE: 3/8" = V---0" OPEN TO LOBBY SCALE: 3/8" = V-0>, JIwj: %M9,11"'m., SCALE: 3/8" = 1'---0" I PAPEP TOWEL DISP WAST RECEPTACLE FAI FILE DRAWER SCALE: 3/8" = 1'-0" WATER COOLER LAVATORY v _ v Jt�QQ C C� DRINKING FOUNTAIN OR ELECTRIC WATER COOLER TO BE INSTALLED IN ACCORDANCE TO SECTION 4.15 OF THE FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION. SEE FLOOR PLAN FOR CLEARANCES III f SCALE: 3/8" = V-0" C-) 7< n ll;z CD m ca L31 UD tv DO FU ru to ru CD C) LL) ED CD m co i U) 3-- rD n a PLASTIC LAM. COUNTER TOP & SPLASH ON 3/4 PLYWOOD CABINET SECTION @ TOILET SCALE: 1" = l'-O" Z-011 PLASTIC LAM. ON TOP & SPLASH ON 3/4" PLYWOOD PLASTIC LAM. ON .1411 3/4" PLYWOOD KEYBOARD DRAWER ZNJ SECTION @ KEYBOARD SCALE: 1 " = l'-O" END PANELS 3/4" PLYWO, PLAM BOTH WIRE PULLS PLAM BASE �Afl"El SCALE: 1 l'-O" 1'-4" NOTE: ALL EXPOSED AND SEMI - EXPOSED SURFACES TO RECEIVE PLASTIC LAMINATE 5/8" GYP BOARD VINYL BASE SECTION @ RECEPTIOl I rv, SCALE: 1" = l'-O" m T-011 PLASTIC LAM. ON SEALANT, TYP TOP & SPLASH ON 3/4- IN PLYWOOD PLASTIC LAM. ON 3/4 PLYWOOD _1`1 DRAWER WIRE PULLS PLASTIC LAM, ON ► 5/8" PLYWOOD BACK P TIC LAM. ON 3k4� PLYWOOD TYPICAL ATT DOORS, SHELVES BOTTOMS P-LAM BASE CABINET SECTION 0 BREAK ROOM PLASTIC LAM, ON f! SINK 3/4" PLYWOOD WIRE PULLS---4[''� PLASTIC LAM, ON 5/8" PLYWOOD BACK- T PLASTIC LAM. ON 3/4- PLYWOOD TYPICAL AT DOORS, SHELVES & I P 14-, -LAM BASE � CABINET SECTION 0 BREAK ROOM, SCALE: 1 " = l'-O" PLASTIC LAM. ON 3/4' PLYWOOD TYPICAL AT DOORS, ADJUSTABLE SHELVES & BOTTOMS WIRE PULLS - SCALE: I " = l'-O" m ri :K ro n 7� C­) rQ C) CD w CD n. CD f__ Lo Lo w ,y CD r,j ru CD . . . . . . ..... LEGEND (NOT ALL FIXTURES USED) 2' X 4' LAY -IN FLUORESCENT SOD CEILING MOUNTED IL-J LIGHT FIXTURE SMOKE DETECTOR 1' X 4' SURFACE MOUNTED EXHAUST FAN LIGHT FIXTURE 0 0 RECESSED DOWNLIGHT FIXTURE 4' 2-BULB, STRIP -TYPE VP FIXED, DIRECTIONAL, VAPORPROOF FLUORESCENT FIXTURE 48" SINGLE -BULB, ENCLOSED FLUOR, GYPSUM BOARD CEILING, ESCENT. WALL -MOUNT 0 84" AFF PAINTED H.V.A.C. DIFFUSER SPRINKLER HEAD RETURN AIR OR ENOTES EXIT LIGHT; SHADED �IT EXHAUST GRILLE DIRECTION OF NEAREST 2' X 4' CEILING GRID HIGH BAY LIGHT 2' X 2' CEILING GRID SURFACE MOUNTED LIGHT HEAT DETECTOR 1 ........ .. i , STUCCO CEILINGPAINTED - COUNG MATE AL / HEIGHT ( 4 W-O" CEILING MATERIAL— CEILING HEIGHT AFF 1 ACOUSTICAL CEILING TILE (24" X 48") 2 PAINTED GYPSUM BOARD 3 STUCCO 4 L_ EXPOSED STRUCTURE - OPEN TO DECK x �o n ry w 0 cx� 0- ZE LO -T, rn CD 7:3 Q 01 ru OD a co w D s M n --4 M CD H C-J Cn CJ Space Hoor CPT Base VB North PTD GYD BD East PTD GYP MRS BD South PTD GYP BD West PTD GYP BD Ce'doing Remarks No. 100 Name OFFICE Material ACT Height 9'-0" 101 BREAKROOM VCT VB PTD GYD BD PTD GYP BD PTD GYP BD PTD GYP BD ACT 9'-0" P-LAM AT MILLWORK 102 MECHANICAL CONC VB PTD GYD BD PTD GYP BD PTD GYP BD PTD GYP BD NONE OTD 103 SHOP MANAGER CPT VB PTD GYD BD PTD GYP BD PTD GYP BD PTD GYP BD ACT 9'-0" 104 UNISEX TOILET CT CTB PTD GYD BD CWT TO 6'-0" PTD GYP BD PTD GYP BD PTD GYP BD 814" EPDXY PAINT/ CERAMIC TILE WAINSCOT TO 5'-0" 105 MENS' TOILET CT CTB PTD GYD BD PTD GYP BD PTD GYP BD CWT TO 6'-0" PTD GYP BD 9'-O" EPDXY PAINT/ CERAMIC TILE WAINSCOT TO 5'-0" 106 STORAGE SEALED CONC VB PTD GYD BD PTD GYP BD PTD GYP 8D PTD GYP BD ACT 9'-0" 107 MANAGER CPT VB PTD GYD BD PTD GYP BD PTD GYP BD PTD GYP 8D ACT 9'-0" 108 HALLWAY CT CTB ^VB PTD GYD BD PTD GYP BD PTD GYP BD PTD GYP BD ACT 9'42 109 RECEPTIONIST CPT PTD GYD BD PTD GYP BD PTD GYP BD PTD GYP BD ACT 9'-0" P-LAM AT MILLWORK 110 LOBBY CT CTB PTD GYD BD PTD GYP BD PTD GYP BD PTD GYP BD ACT 9'-0" 200 DETAILING AREA SEALED CONC NONE PTD GYD BD PTD CMU PTD CMU PTD CMU PTD CMU NONE OTD FLOOR: BROOM FINISH, EPDXY PAINT H�=_ I W, E., CPT CARPET VCT VINYL COMPOSITION TILE VB VINYL BASE P-LAM PLASTIC LAMINATE PTD GYP BD PAINTED GYPSUM BOARD ACT 24" X 48" ACOUSTICAL CEILING TILE SEALED CONC SEALED CONCRETE CT CERAMIC TILE CTB CERAMIC TILE BASE OTD OPEN TO DECK P R 0 V 15QIlkOJIS FOR BARMIER FREE DOORN PUSH SIDE 18" MINIMUM 24" PREFERRED3 z CO if NOTE. x = 12 IN IF THE DOOR (A) FRONT APPROACHES HAS BOTH A CLOSER AND A LATCH, PULL SIDE 54� M_ INIMU " I x PUSH SIDE CHANGES IN LEVELS IN ) UNIG APPROACHES NOTE: y 48 IN MIN. IF DOOR HAS ACCESSIBLE ROUTES NOTE: x = 36 IN MINIMUM IF y = 60 IN BOTH A LATCH AND A CLOSER. x = 42 IN MINIMUM IF y = 54 IN. 1-1 11 PULL 51DF PUSH SIDE � 24" MINIMUM 24" MIIN. NOTE: ALL DOORS IN ALCOVES x SHALL COMPLY WITH THE Co CLEARANCES FOR FRONT APPROACHES. NOTE: y - 54 IN MINIMUM IF THE DOOR HAS A CLOSER. (0 LATCH SDE APPROACKS NOTE: y = 48" IN MINIMUM IF THE DOOR HAS A CLOSER. 5'_0„ V4' TJTD GLASS, TYPICAL PROVIDE MAXMN SHADING COEFFICIENT OF 0.7 AT ALL EXTERIOR WINDOWS NO = 1`1ASONRY OPENING SCALE: Y4" = I'-01' An Wvv�')� M ill :rnai" wvv" wluvri NUMBER a 0100 3'-0" X 6-6, X I%' FRAMES DETAIL n au ear - 7 Ti�M1d68Ho0a9 - nowcTm PAWL FaE RATM KS E.EY F MATEMAL SC WOOD MNM TYPE STAIN 2 MATEMA HOL MU HEAD PAINT 9/A8.2 JAMB q/A8,2 - - - 9101A 3'-0' X 6'-8' X I%i' F HOL f1TL PAINT 2 HOL NTL PAINT q/A8,2 q/A8.2 - 5- 910113 3'-0"X6'-8' CASED OPENG - - 2 HOL NTL PAINT 10/A6.2 IO/A8.2- 9102 (2) 2'-0' X 6'-8' BF Sc W00D STAIN - WOOD PAINT - - - 6 P103A 3'-0" X 6'-0" X IA" F SC WOOD STAIN 2 HOL NTL PAINT q/A8.2 q/A8.2 - 7 D1038 3'--O" X 6'-8' X I%' F HOL MT PAINT 2 NOL NTL PAINT 9/A8.2 q/A8.2 - 7-- 0104 3'-O" X 6-8' X I%' F SC WOOD STAIN 2 Ha NTL PAINT q/A8.2 q/A8.2 4 MARBLE - - - UC 1/2", 180d SWAG D105 3'-0" X 6"-8' X i' F HOL NTL PAINT 2 HOL NTL PAINT 9/A8.2 q/A8.2 - 3 NARBLE - - - UNDERCUT I' DID6 S-0" X 6'-8' X I%' F HOL NTL PAINT 2 H0L NTL PAINT 9/A8.2 9/A8.2 - 8 - _ _ _ DI07 3"-0' X 6'-8' X 1 ' F SG WOOD STAIN 2 HOL NTL PAINT /A8.2 q/A8.2 - 7- DIOq 3"-0' X 6'-8' X l " F SC WOOD STAIN 2 H0L NTL PAINT q/A8.2 q/A8.2 - 7- -- DIIO 3"-O' X 7'-0" X 1%, SF AL/GL ANOO 3 ALUM A" 5/A8.2 5/A8.2 I/A8.2 I METAL - - TEMP 114A 3'-0' X 6-8" X I%' D2OOA l4'-0" X I2'-O' P OH Sc WOOD I TAL STAIN FACTORY - WOOD - PAINT - - 7/A8.2 - 6/A8.2 - 7 - NFR - - 20 MIN. - CLOSER D2006 14'-0' X 12'-0' OH METAL FACTORY - - - 7/A8.2 6/A8,2 - NPR 5200C S-0" X 7'-0' X IY4' F HOL NTL PAINT I HOL NTL PAINT 3/A8.2 2/A8.2 4/A&2 2 METAL D200D 3 -0' X 7'-0' X 1%' F HOL NTL PAINT I HOL NTL PAINT 3/A8.2 2/A8.2 4/A8.2 2 METAL HARDWARE UMTY / ACCESMffy CODE ALL DOORS TO BE PROVIDED WITH HARDWARE (LEVER TYPE) TIGHT PINCHING OR TWISTING OF THE WRIST TO OPERATE; IN HAVING A SHAPE THAT IS EASY TO GRASP WITH ACCORDANCE WITH FLORIDA STATUTES CHAPTER ONE HAND AND DOES NOT REQUIRE TIGHT 553, PART FLORIDA GRASPING, V, ACCESSIBILITY CODE 4,13.9 HARDWARE SPMHCAT�ONS DESO BASIS SET SET _ HINGES, INTERIOR DOORS HAGER BB1191 40 x 40 626 #1 EXTERIOR STOREFRONT EXIT SINGLE #5 EXIT, PASSAGE HINGES, EXTERIOR DOORS HAGER BB'1199 NRP 46 x 40 630 1 EXIT DEVICE (PANIC HARDWARE BALANCE OF HARDWARE 1-1/2 PAIR BUTTS BY D00 MFR 1 EXIT DEVICE CLOSER LCN 1460 SERIES SNB 689 1 OVERHEAD STOP 1 MOP PLATE (DETAIL SIDE) LOCKSET / LATCHSET _ SCHLAGE RHODES SERIES 626 1 KICKPLATE (OFFICE SIDE) #2 EXTERIOR EXIT #6 BIFOLD FLUSH BOLTS _ ROCKWOOD 555 630 1-1/2 PAIR BUTTS 1 RAIN DRIP HARDWARE BY DOOR MANUFACTURER EXIT DEVICE MONARCH F-18-M 630 1 THRESHOLD 1 OVERHEAD STOP 1 WEATHERSTRIPPING PUSH PLATE ROCKWOOD 70 6" x 16" 630 1 EXIT DEVICE PULL PLATE _ ROCKWOOD 110 x 70C 630 #3 RESTROOM, PASSAGE #7 OFFICE, KEYED KICK PLATE ROCKWOOD 8 x 2" LOW 630 1-1/2 PAIR BUTTS 1 PASSAGE LOCKSET 1 MOP PLATE 1 KICKPLATE 1-1/2 PAIR BUTTS 1 KEYED LOCK ET MOP PLATE ROCKWOOD 4 x 2" LOW 630 STOP 1 OVERHECLOSER 1 CLOSER 1 THRESHOLD 1 WALL STOP �AT DOORS D103A & D109) 1 RAIN DRIP 1 WEATHERSTRIPPING 1 OVERHEAD STOP AT DOORS D10O & D107 ( ) WALL STOP ROCKWOOD 406 OR 409 630 OVERHEAD STOP GLYNN-JOHNSON 905 630 #4 RESTROOM, PRIVACY 1-1/2 PAIR BUTTS #8 STORAGE WEATHERSTRIPPING PEMKO 303AV 1 PRIVACY LOCKSET 1 WALL STOP 1-1/2 PAIR BUTTS 1 STORAGE LOCKSET THRESHOLD PEMKO 2005AV_ 1 MOP PLATE 1 OVERHEAD STOP 1 MOP PLATE (DETAIL SIDE} 1 KICKPLATE RAIN DRIP PEMKO 346D 1. ALL DOORS SHALT. HAVE SAME ELEVATION WITH NO MORE THAN 1/4" DIFFERENCE ON EITHER SIDE OF THRESHOLD. 2. ALL DOORS AND WINDOWS SHALL HAVE CAULK ON INTERIOR PERIMETER AND SEALANT ON EXTERIOR PERIMETER. 3. ALL HARDWARE TO BE BORED TYPE. 4. COORDINATE ALL LOCKSETS WITH OWNER " PER " scHEDUL o a o � i TO (� 3 2" FRAMES TYPICAL l ' - ' ❑ TEMPERED GLASS FRAME ELEVATONS SCALE: %° = r-0" 2° PER " SCHEDUL TO TO C-) 1 n "17 n ro ro n cn i N 0 t� 0 Lo Lo CD A C to LD F—> L`. O Q Q H m n c r- O Z A F-) UJ r- r n w� li 1 150'-011 Y a PLAN �q�2p SCALE 1/8" = l'-O" NORTH " ARCHITECTURAL DYNAMICS, LLC 2816 PICKFAIR STREET ORLANDO, FL 32663-6827 i i" fl J— arn� R s.vn W. r CD ro t-3 -3 s ID cn 0 a W 0 Cl Lo w cn ru 0 ID W a CD Ln ro :F- n M r) c-t- c a 5" CONCRETE SLAB WITH 4" CONCRETE SLAB WITH FIBERMESH - SEE PLAN FIBERMESH - SEE PLAN FOR SLAB DEPTH - FOR SLAB DEPTH FINISHED FIRST FLOOR O'—O" REFERENCE DATUM) —�— Q 1135 4 4 (3) #53 CONT. W/#3 CROSS —TIES AS NEEDED - _ I I1 ;I t �. J I I-- TEE-] -__ _ I � TEE-2 SCALE: N' == 1'-0ar SCALE: Y" = 1'-0" DESIGN CRITERIA: 01 ALL WORK SHALL CONFORM TO AT LEAST THE MINIMUM STANDARDS OF THE STANDARD BUILDING CODE LATEST EDITION. GENERAL: G1 THE GENERAL CONTRACTOR SHALL REVIEW AND DETERMINE THAT DIMENSIONS ARE COORDINATED BETWEEN ARCHITECTURAL AND STRUCTURAL DRAWINGS PRIOR TO FABRICATION OR START OF CONSTRUCTION. G2 NO STRUCTURAL. MEMBER SHALL BE CUT, NOTCHED OR OTHERWISE REDUCED IN STRENGTH. G3 THE GENERAL CONTRACTOR SHALL COORDINATE ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS FOR ANCHORED, EMBEDDED OR UNLESS OTHERWISE NOTED OR DETAILED, SUPPORTED ITEMS WHICH AFFECT THE STRUCTURAL DRAWINGS, G4 ALL SECTIONS AND DETAILS SHALL BE CONSTRUED TO BE TYPICAL UNLESS OTHERWISE NOTED OR DETAILED. G5 6 MILLIMETER VAPOR BARRIER FOUNDATIONS: F1 CONTRACTOR SHALL DETERMINE IF ANY UNSUITABLE CONDITIONS ARE DISCOVERED DURING EXCAVATION WHICH WOULD PREVENT ATTAINMENT Of THE DESIGN SOIL PRESSURE REQUIRED BY THE SOILS REPORT. SCALE: 74" = I`-0" PAINT TRAP 6" DIA STE FILLED WITI 1/2" EXPA PAVING OR CONCRETE DEEP AND #5 REBAR r r' SCALE: N' = I'--0` OL FINISHED FIRST FLOOR 0'-0" REFERENCE DATUM) G5 11 I- 1r (3]1 AS NWNEEDED 6,PROVIDE 6" WIDE LEDGE AT VENEER AT OFFICE (SEE S.1 FOR LOCATIONS) CONCRETE & REINFORCING: Cl CONCRETE WORK SHALL CONFORM TO ACI CODE REQUIREMENTS FOR REINFORCED CONCRETE (ACI 318-89). C2 ALL CONCRETE SHALL HAVE A MIN. 28 DAY STRENGTH AS FOLLOWS: FOUNDATIONS, FILLED CELLS, TIE BEAMS, SLABS ON GRADE - 3,000 psi C3 REBARS SHALL CONFORM TO ASTM-615 GRADE 60. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185. C4 SPLICES AND ANCHORAGE OF REINFORCING SHALL BE AS FOLLOWS UNLESS OTHERWISE NOTED: WELDED WIRE FABRIC: 6" ALL OTHERS: SEE DETAILS C5 REINFORCING IN WALLS, FOOTINGS AND BEAMS SHALL BE CONTINUOUS AND LAPPED 36X BAR DIAMETER AT SPLICE UNLESS OTHERWISE NOTED. HOOK AND LAP ALL CORNER AND INTERSECTING BARS. C6 MINIMUM COVER FOR REINFORCING SHALL BE DETAILED, 5" CONCRETE SLAB WITH FIBERMESH — SEE PLAN FOR SLAB DEPTH li I FINISHED FIRST FLOOR — - -a--�- ` 0'-0" REFERENCE DATUM) _ Q p i i 11- I 4. 4 == G5 Q 11= (3) #5s CONT. W/#3 1 �J�I ICI I CROSS —TIES AS NEEDED IS" SCALE: I" = 1'-0" FILLED CELL (TYP.) W/ #5 VERTICAL REINFOprlmn (Tvp 1 CUNT, PVC CONTROL JOINT INSERT #5 VERTICAL REINFORCING (TYP.) CONTROL BLOCK UNIT CONT. BACKER ROD AND SEALANT BOTH SIDES, 3/8" JOINT TYP. 1) '-MCJ.' MASONRY CONTROL JOINT 2) PROVIDE A DUMMY JOINT AT TIE BEAMS IN LINE W/ MCJ. [M-l"W�filiz�:llljlq SCALE: A" = I'--0" MASONRY: Ml MASONRY SHALL CONFORM TO ACI STANDARDS & BUILDING CODE REQUIREMENTS FOR CONCRETE MASONRY (ACI 530-881 ASCE 5-88) AND SPECIFICATIONS FOR MASONRY STRUCTURES (ACI 530.1-881 ASCE 6-88). M2 CONCRETE BLOCKS SHALL CONFORM TO ASTM C-90. M3 MORTAR SHALL COMPLY WITH ASTM C270, TYPE'M' OR'S'. N PLAN VIEW m y MARK LENGTH REMARKS HP1 20'-0" #5 REBAR HAIRPIN BENT TO 90d ANGLE, EACH LEG APPROX. 10'--0" HP2 20'-0" #5 REBAR HAIRPIN BENT TO 45d ANGLE, EACH LEG APPROX. '10'-0" USED AT INSIDE CORNERS -, fliil r MARK REMARKS DETAIL TDE-1 TURNED DOWN EDGES TO BE 18" WIDE X 24" DEEP CONTINUOUS AROUND -/ S.2 PERIMETER OF SLAB W/ (3) #5 REBAR CONTINUOUS/LAPPED 5" DEEP SLAB TDE-2 TURNED DOWN EDGES TO BE 18" WIDE X 24" DEEP CONTINUOUS AROUND -/ S.2 PERIMETER OF SLAB W/ (3) #5 REBAR CONTINUOUS/LAPPED 4" DEEP SLAB 1. 20' LONG #5 REBAR HAIR PIN TYPICAL AT F1 & F2 2, THIS DESIGN WILL MEET THE 120 MPH WIND LOAD AS PER SECTION 1606 OF THE 2001 FBC 3. REFER TO "USA" ANCHOR BOLT LAYOUT FOR EXACT LOCATION OF COLUMNS NOTES 1, ANCHOR BOLTS SHALL BE MANUFACTURED AND PLACED IN CONFORMANCE WITH METAL BUILDING MANUFACTURER'S SPECIFICATIONS. 2. FOUNDATION DESIGN IS FOR PRE—ENGINEERED METAL BUILDING. SHOP DRAWINGS INCLUDING REACTIONS SIGNED AND SEALED BY A FLORIDA REGISTERED ENGINEER SHALL BE SUBMITTED FOR APPROVAL PRIOR TO FABRICATION AND/OR FOUNDATION POUR. 1 PRE—ENGINEERED METAL BUILDING SHALL MEET MINIMUM LOAD REQUIREMENTS OF 2001 FBC, 120 MPH REGION. 4. DESIGN WIND LOADS IN CONFORMANCE WITH 2O01 FBC, 110 MPH REGION. 5. FINAL PRE—ENGINEERED METAL BUILDING FOUNDATION DESIGN MAY BE ADJUSTED PER FINAL LAYOUT BY METAL BUILDING MFR., SIGNED AND SEALED BY A REGISTERED ENGINEER IN THE STATE OF FLORIDA. 5. VERIFY SLAB ELEVATIONS WITH CIVIL. ELEVATION I r C r CD n 7) ZT r 0 0 w M CL en w ti w .ram cb ru 0 0 W a c� z H m 0 I- D H m cn r- r- ® HVAC KEY NOTES: M1: PROVIDE AND INSTALL NEW 24" X 24" STAMPED FACE OFF WHITE STEEL SUPPLY AIR CEILING DIFFUSER EQUAL TO TITUS TMS. BALANCE TO NOTED CFM WITH MANUAL VOLUME DAMPER IN SPIN IN FITTING. NECK SIZE AND CFM ARE NOTED ON THE PLAN. M2: PROVIDE AND INSTALL NEW 12" X 12" STAMPED FACE OFF WHITE STEEL SUPPLY AIR CEILING DIFFUSER EQUAL TO TITUS TMS. BALANCE TO NOTED CFM WITH MANUAL VOLUME DAMPER IN SPIN IN FITTING. NECK SIZE AND CFM ARE NOTED ON THE PLAN. M3: PROVIDE AND INSTALL NEW 24" X 24" LOUVERED FACE OFF WHITE STEEL RETURN AIR FILTER GRILLE EQUAL TO TITUS 35ORLF1 WITH 20" X 20" 1" TA MEDIA. BALANCE TO NOTED CFM WITH MANUAL VOLUME DAMPER IN SPIN IN FITTING. NECK AND CFM ARE NOTED ON THE PLAN. PROVIDE SQUARE TO ROUND ADAPTOR AS REQUIRED, M4: PROVIDE AND INSTALL NEW 24" X 24" LOWERED FACE OFF WHITE STEEL TRANSFER AIR GRILLE EQUAL TO TITUS 35OR WITH NO MANUAL VOLUME DAMPER. NECK SIZE AND CFM (FOR ACCOUNTING PURPOSES) ARE NOTED ON THE PLAN. PROVIDE SQUARE TO ROUND ADAPTOR AS REQUIRED. M5: PROVIDE AND INSTALL NEW LOUVERED FACE STEEL RETURN AIR FILTER REGISTER WITH INTEGRAL VOLUME DAMPER EQUAL AND WITH 1" TA FILTER MEDIA. EQUAL TO TITUS 35ORLF1 IN SIDE OF WALL AS SHOWN. NECK SIZE AND CFM ARE NOTED ON PLAN. IN LIEU OF INTEGRAL DAMPER, A FABRICATED SLEEVE AND DAMPER MAY BE USED. M6: SUGGESTED LOCATION OF 120 VAC CONV. OUTLET PER FMC AND NEC. M7: PROVIDE AND INSTALL NEW 16" X 16" STORM PROOF PRIMED ALUMINUM OUTDOOR AIR LOUVER WITH AN ALUMINUM BIRD SCREEN AND 1" WASHABLE; REMOVABLE ALUMINUM FILTER. ELEVATION AND CFM ARE INDICATED ON THE PLAN. PRIME AND PAINT. SELECTION OF COLOR BY OWNER. M8: PROVIDE AND INSTALL NEW 16" X 8" STORM PROOF PRIMED ALUMINUM EXHAUST AIR LOUVER WITH AN ALUMINUM BIRD SCREEN. ELEVATIONS AND CFM INDICATED ON PLAN. PRIME AND PAINT. SELECTION OF COLOR BY OWNER. M9: PROVIDE AND INSTALL 3/4" SOLVENT WELDED SCHEDULE 40 PVC CONDENSATE PIPE WITH A 3" P TRAP AND CLEANOUT AT AHU. MANIFOLD TO 1.25" PIPE. ROUTE BELOW SLAB TO DRYWELL. M10: PROVIDE AND INSTALL 24" DIAMETER X 24" HIGH DRYWELL WITH PEA GRAVEL FILL. DRYWELL MAY BE COVERED WITH SOD PER FMC. COORDINATE LOCATION WITH INTERCEPTOR (BY PLUMBING CONTRACTOR). MI 1: INSTALL CONDENSING UNIT ON 4" CONCRETE PAD WITH THICKENED EDGE AND EXTENDED 4" AROUND UNIT. STRAP THE COND. UNIT TO THE SLAB WITH 4 (1 PER SIDE WITHOUT ACCESS OBSTRUCTION) 26 GA. GALV: STRAPS, #10 GALV. SELF -TAPPING SCREWS, AND 1/4" TAPCONS WITH 1" EMBED. a� HVACPLAN. SCALE 1/16" _ NORTH M12: ROUTE SUCTION AND LIQUID PIPING FROM EACH AHU IN PVC CONDUIT BELOW THE SLAB TO THE CORRESPONDING CONDENSING UNIT. SEAL PENETRATIONS,. MOISTURE AND VERMIN PROOF, M13: PROVIDE AND INSTALL NEW 4 TON SPLIT SYSTEM DX CONDENSING UNIT (CU) EQUAL TO CARRIER MODEL 38CKC048, 48,000 BTUH TOTAL COOLING CAPACITY, 10.0 SEER. 208 VAC SINGLE PHASE. 31.9 MCA, 50 AMPS MAX NEC DISCONNECT. PROVIDE WALL MOUNTED ADJUSTABLE T'STAT WITH LOCKING COVER SET AT 74d-F. DISCONNECT BY ELECTRICAL CONTRACTOR. M14: PROVIDE AND INSTALL NEW 4 TON SPLIT SYSTEM DX AIR HANDLING UNIT (AHU) WITH ELECTRIC HEAT EQUAL TO CARRIER MODEL FB4ANO48. 1,600 CFM SUPPLY AIR. 160 OUTDOOR AIR CFM. 314 HP FAN MOTOR AND 7.5 KW HEATER (AT RATED VOLTAGE) WITH SINGLE POINT WIRING KIT AT 208 VAC SINGLE PHASE. DISCONNECT BY ELECTRICAL CONTRACTOR. UNIT WEIGHTS 175#. M15: PROVIDE AND INSTALL NEW 2 TON SPLIT SYSTEM DX CONDENSING UNIT (CU) EQUAL TO CARRIER MODEL 38CKCO24. 24,000 BTUH TOTAL COOLING CAPACITY, 10.0 SEER. 208 VAC SINGLE PHASE. 15.5 MCA, 20 AMPS MAX NEC DISCONNECT. PROVIDE WALL MOUNTED ADJUSTABLE. T'$TAT WITH LOCKING COVER SET AT 74d F. DISCONNECT BY ELECTRICAL CONTRACTOR. M16: PROVIDE AND INSTALL NEW 2 TON SPLIT SYSTEM DX AIR HANDLING UNIT (AHU) WITH ELECTRIC HEAT EQUAL TO CARRIER MODEL F84ANO24. 800 CFM SUPPLY AIR. 50 OUTDOOR AIR CFM. 1/4 HP FAN MOTOR AND 6 KW HEATER (AT RATED VOLTAGE) WITH SINGLE POINT WIRING KIT AT 208 VAC SINGLE PHASE. DISCONNECT BY ELECTRICAL CONTRACTOR. UNIT WEIGHS 112#. M17: PROVIDE AND INSTALL NEW CEILING MOUNTED EXHAUST FAN EQUAL TO COOK GEMINI GC-140. 100 CFM AT 0.375" ESP. 70 WATTS AT 120 VAC. PROVIDE UNIT WITH MANUAL STARTER, DISCONNECT, CEILING GRILLE AND INTEGRAL BACKDRAF`r DAMPER. INTERLOCK FAN WITH LIGHT SWITCH IN ROOM. INSTALL UNIT ABOVE CEILING WITH INTEGRAL CEILING MOUNTING CLIPS. UNIT WEIGHS 15#. M18: PROVIDE AND INSTALL NEW CEILING MOUNTED EXHAUST FAN EQUAL TO COOK GEMINI GC-180. 230 CFM AT 0.375" ESP. 192 WATTS AT 120 VAC. PROVIDE UNIT WITH MANUAL STARTER, DISCONNECT, CEILING GRILLE AND INTEGRAL BACKDRAFT DAMPER. INTERLOCK FAN WITH LIGHT SWITCH IN ROOM. INSTALL UNIT ABOVE CEILING M19: PROVIDE AND INSTALL NEW WALL MOUNTED EXHAUST PAN WITH INTEGRAL SLEEVE, SHUTTER, OSHA GUARD AND HEAVY DUTY POWER ASSEMBLY EQUAL TO COOK WALL PAC 30XLPH. 8134 CFM AT 0. 15" WG 120 VAC.1 HP NEC DISC BY ELECTRICAL TRADE. CONTROL WITH WALL SWITCH. ADJACENT TO SWITCH PROVIDE ENGRAVED PLASTIC SIGN TO READ "OPERATE FAN ONLY WHEN DOOR IS OPENED". UNIT WEIGHS APPROX 275#. SUPPORT AT METAL BUILDING WALL BY METAL BUILDING MANUFACTURER OR STRUCTURAL- ENGINEER ONLY. M20: PROVIDE AND INSTALL NEW STORM PROOF PRIMED ALUMINUM OUTDOOR AIR LOUVER WITH AN ALUMINUM BIRD SCREEN. ELEVATION AND CFM ARE INDICATED ON THE PLAN. A PRIME AND PAINT. SELECTION OF COLOR BY OWNER. GENERAL_ MECHANICAL NOTES: 1. THE DRAWING DEPICTS THE REQUIRED HVAC SCOPE OF WORK WHICH IS ASSOCIATED WITH NEW CONSTRUCTION. 2. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE 2001 FLORIDA MECHANICAL CODE (FMC), FPA 90A AND 101, ASHRAE, SMACNA, NEC AND SANFORD, FLORIDA (AHJ). 3. CONTRACTOR SHALL OBTAIN THE NECESSARY PERMITS AND PAY THE ASSOCIATED FEES. 4. COORDINATE ALL WORK WITH THE OWNER AND ALL TRADES. 5. ALL NEW RIGID SUPPLY, RETURN AND MIXED AIR DUCTWORK SHALL, BE 1.5" THICK FIBERGLASS DUCT130ARD WITH A MIN R VALUE OF R-6.0. ALL NEW RIGID. OUTDOOR AND EXHAUST AIR DUCTWORK SHALL BE GALV. STEEL SNAP LOCK. ALL DUCT AND INSULATION JOINTS SHALL BE MADE WITH GLASS FAB AND APPROVED MASTIC. FABRICATE AND SUPPORT ALL DUCTWORK IN ACCORDANCE WITH SMACNA. DUCT DIMENSIONS REFERENCED ARE CLEAR INSIDE DIMENSIONS. ALL NEW FLAXIBLE SUPPLY AIR, TRANSFER AIR AND RETURN AIR DUCTWORK SHALL BE CONSTRUCTED TO SMACNA STANDARDS WITH AN INTEGRAL VAPOR BARRIER AND A MIN R VALUE OF R-6.0. ALL DUCTWORK, MASTICS, ETC. SHALL HAVE MAX. 25 FLAME SPREAD AND MAX. 50 SMOKE DEVELOPED RATINGS. 6. APPLY 2.2" THICK 3/4 POUND DENSITY FIBERGLASS INSULATION WITH AN FSK VAPOR BARRIER AND GLASS FAB AND MASTIC TO THE TOP OF THE NEW CEILING SUPPLY AIR DIFFUSERS. 7. NO INDIVIDUAL AHU HAS A CAPACITY GREATER THAN 2000 CFM. EACH AHV IS ASSOCIATED WITH A SEPARATE PLENUM AND AS SUCH NO DUCT MOUNTED SMOKE DETECTORS ARE REQUIRED PER FMC. 8. AIR DISTRIBUTION TEST AND BALANCE SHALL BE DONE IN ACCORDANCE WTIH NESS OR AABC REQUIREMENTS BY INDIVIDUALS FAMILIAR WITH THE PROCEDURES AND PRACTICES INVOLVED. 9. PROVIDE THE OWNER 3 COPIES OF ALL EQUIPMENT GUARANTEES, WARRANTIES, PART LISTS, ETC. SCHEDULE A MINIMUM OF 2 HOURS AT THE PROJECT SITE TO FAMILIARIZE THE OWNER OR DESIGNATED REPS WITH THE WAYS IN WHICH THE SYSTEMS ARE OPERATED AND MAINTAINED, 10. LOCATIONS OF T'STATS AR SUGGESTED. VERIFY ACCEPTANCE WITH THE OWNER PRIOR TO INSTALLATION. HEIGHTS SHALL CONFORM TO ADA REQUIREMENTS. 11. PROVIDE PROPER ACCESS FOR ALL MECHANICAL EQUIPMENT COMPONENTS REQUIRING SERVICE, ACCESS, INSPECTION AND USE IN ACCORDANCE' WITH THE MANUFACTURER'S RECOMMENDATIONS, FMC AND AHJ. 12. THERE ARE NO DUCT OR PIPING PENETRATIONS OF ANY FIRE RATED ASSEMBLIES AND AS A RESULT, NO FIRE DAMPER DETAILS OR PIPING PENETRATION DETAILS ARE SHOWN. 13. INSULATE ALL SUCTION REFRIGERANT PIPING WITH 1/2" ARMSTRONG ARMAFLEX INSULATION WITH 2 COATS OF ARMSTRONG FINISH APPLIED TO ALL EXPOSED INSULATION AT THE CONDENSING UNITS. 14. ALL CONDENSATE PIPING SHALL BE S-40 PVC WITH SOLVENT WELDED JOINTS. 15. PER THE FMC, THERE ARE A MAX OF 8 PEOPLE IN THE BUILDING EACH REQUIRING 20 CFM OUTDOOR AIR OR A TOTAL OF 160 CFM. 200 CFM HAS BEEN SPECIFIED. TOILET AND UTILITY ROOMS HAVE BEEN EXHAUSTED AT 2 GFM PER SE IN EXCESS OF THAT REQUIRED PER THE FMC, � I i 1 I I 1 _ LARGE CAPACITY RESIDENTIAL ELECTRIC DRYER BY OTHERS '* HWto 4 4" 0 GALV STEEL WITH NO PROTRUDING FASTENERS TO WALL CAP BOTTOM 10' AFF 200 CFM AllRI-4 P ARCHITECTUML DYNAMICS, LLC ORLANDO, FL .F •.. PHONE: FAX 40. `96 3501 archsolve@aol.com FL LIC NO: W.00 f/irii/r 1 CONSTRUCnON CO. GENERAL r '! /j CONTRACTORS ,I MONROE , r SANFORD, PH 407 323 1150 0 igAddress: P.O. BOX 471366 LAKE MONROE, FL 6 drodd@mckeeconsftucfionco.com A. PETER TANKEL, P.E. oommnNG ENGR&M ;' SUM AW14 I K S �t .4 is w A. f fI t ilt"211 1 {' f" vA E, k � C-) n 2ZZ M ti iv c_ CD Lil Ln F\J CD CD CD 71 0) GC FABRICATED PLYWOOD PLATFORM, MANUAL VOLUME DAMPER (TYP.) NOTE: OA, RA BEYOND BUT SHOWN AT SIDE FOR CLARITY ROOF/METAL DECK RA PURLINS (TYP) S/A OA S/A OA RA MIN. #12 GALV, WALLS AHU AHU STEEL WIRE 00 00 2" WIDE GALV. CHANNEL RAFG REGISTER FINISH _FLOOR > 1.5" DUCTBOARD R-6.0 (GLASS FAB/ MASTIC) SEPARATE MIXED AIR 1.5", R-6.0 F.G. PLENUM SECTIONS DUCTBOARD W/ GLASS FAB AND MASTIC (TYP) TRAPEZE DETAIL HVAC SECTION NOT TO SCALE NOT TO SCALE SEAL SPIN -IN FITTING WITH MASTIC. CLEANOUT SPIN -IN FITTING WITH VOLUME DAMPER AIR HANDLING UNIT 311 MIN, 1.5" WIDE GALV. STRAP FLEX DUCT SIZE SAME fit AS NECK SIZE,, _Tl CLEANOUT RIGID DUCT F CEILING DIFFUSER SEE FLOOR PLANS FOR PIPING ROUTING DIFFUSER DETAIL NOT TO SCALE t,.,,vNDENb"ftATE DRAIN NOT TO SCALE lill . . . . . . . . . . . W `O C CD CD U) m cn c CD 0 W m cn 0. x CQ --1 n c cn tv ru W L, ry 0 CD W c� M m m x> r- 0 n m M n T- r ULLBOX TO BE PROVIDED ITH TRAFFIC -RATED COVER IN, 12" X 18" X 12" DEEP 7NDUIT WITH WIRES, [ZE AS INDICATED J THE: DRAWINGS, FOR POLE SLIGHT POLE INSTALLATION DETAIL SCALE: NONE PANEL: SL VOLTAGE: 120/208/3PH MOUNTING: SURFACE A.I.C. SPACES: 30 SECTION: WL0 22 KA SERIES RATED 1 OF 1 CIRCUIT L AMP POLE CIR CIR AMP POLE ! CIRCUIT LABEL A B C. CO NO. NO. CB A B C LABEL SITE LTG 16 20 2 1 2 20 2 16 SITE LTG 16 3 4 16 SITE LTG 16 20 2 5 6 20 2 16 SITE LTG 16 7 8 16 SITE LTG 16 20 2 9 10 20 2 16 SITE LTG 16 If 12 16 SITE LTG 16 20 2 13 14 20 2 16 SITE LTG t6 15 16 16 SITE LTG 11 20 2 17 18 20 2 11 SITE LTG 11 19 20 11 SITE LTG 11 20 2 21 22 20 2 1 t SITE LTG it 23 24 11 SITE LTG 11 20 2 25 26 20 2 9 SITE LTG 11 27 28 9 29 30 NO DEMAND TAKEN CIRCUITS t8,20,9,11,13,15,6,826,28 TO BE ROUTED TO (2) 6 POLE CONTACTORS CONTROLLED BY A PHOTOCELL CIRCUITS 14,16,18,20,22,24,1,3,5,7,17,19,21,23,25,27,2,4 TO BE ROUTED TO (3) 6 POLE CONTACTORS CONTROLLED BY A TIME CLOCK 138 138 108 TOTAL LIGHTING CONTACTORS o 4-# 1-1 5CU,h 4"C 6CU RND o �q�zp SCALE: I" = 40'-O" 1(9 5 00 NI QC)°lo�,— �7,— A Q1 l\A/ Q 0 O 0 NORTH LIGHTING FIXTURE SCHEDULE: TO SITE LIGHTING FIXTURE SLA: (2) LSI #CT2H-3-400-MHR-F-208-BRZ MOUNTED ON 35' CONCRETE POLE. FIXTURE AND POLE TO BE FURNISHED BY OWNER, CONTRACTOR TO CONTACTOR MOUNTING DETAIL OBTAIN FIXTURE FROM OWNER'S ON SITE STORAGE AND INSTALL SCALE: NONE SLA: (2) LSI #CTL-3-1000-MHR-F-208-BRZ MOUNTED ON 35' CONCRETE POLE. 1. PROVIDE CONTACTORS AS INDICATED ON PANEL SCHEDULE. FIXTURE AND POLE TO BE FURNISHED BY OWNER. CONTRACTOR TO CONTACTORS TO BE ELECTRICALLY HELD IN NEMA 1 ENCLOSURE PROVIDE TIMECLOCK OR PHOTOCELL AS INDICATED TO CONTROL CONTACTORS. OBTAIN FIXTURE FROM OWNER'S ON SITE STORAGE AND INSTALL TIMECLOCK TO BE 7 DAY, ASTRO-DIAL, SPRING WOUND WITH BACK-UP 2. PROVIDE 12"X12" 36" WIREWAY BELOW CONTACTORS FOR REDUCTION GENERAL NOTE: a OF WIRE SIZE TO CONNECT TO CONTACTOR, PROVIDE TERMINAL BLOCKS 2 QUANTITY AS REQUIRED TO REDUCE WIRING FROM #4 TO #10. WIRING FROM POLE TO BE SIZED FOR 140 MPH WIND WITH 1.3 GUST FACTOR AT RATED EPA TERMINAL BLOCK THRU CONTACTOR TO PANEL TO BE #10 THHN CU. OF FIXTURE. INSTALL IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, SITE LIGHTING PLAN CD cu W ZT CD ru m -11 to DO CD CD .3 C'D rr- n .ELECTRICAL SYMBOL LEGEND SYMBOL DESCRIPTION CEILING OUTLET BOX AND FLUORESCENT FIXTURE 4c=r EMERGENCY LIGHTS (BATTERY PACKS) 0 CEILING OUTLET BOX AND LIGHT FIXTURE CH WALL OUTLET BOX AND LIGHT FIXTURE CEILING OUTLET BOX AND EXIT LIGHT FIXTURE (SHADING INDICATES FACE) WALL OUTLET BOX AND SINGLE POLE SWITCH 20 AMP, 125V WALL OUTLET BOX AND THREE—WAY SWITCH 20A. WALL OUTLET BOX AND 3/4"C TO CEILING FOR TELEPHONE AND DATA WALL OUTLET BOX AND SPECIAL PURPOSE RECEPTACLE WALL OUTLET BOX AND 20 AMP,125V DUPLEX RECEPTACLE WALL OUTLET BOX AND 20 AMP DUPLEX RECEPTACLE D B-1/ VA !��Om RECEPTACLE MOUNTED ABOVE COUNTER. RECEPTACLE TO, BE PHOTOCELL GFI TYPE AT SINKS, RESTROOMS AND FOOD SERVICE AREAS. GFI WALL OUTLET BOX AND 20 AMP GFI RECEPTACLE (WPG=WEATHERPROOF GROUND FAULT. COVER TO BE LISTED AS WEATHERPROOF WITH CORD CAP INSERTED) WALL OUTLET BOX AND (2) 20 AMP DUPLEX RECEPTACLES FLUSH WALL OR CEILING JUNCTION BOX SURFACE MOUNTED JUNCTION BOX DISCONNECT SWITCH, SIZE AS NOTED X E MOTOR CONNECTION, AS NOTED 120/208V BRANCH CIRCUIT PANELBOARD SURFACE MOUNTED TELEPHONE TERMINAL BOARD r BRANCH CIRCUIT CONDUIT CONCEALED ABOVE CEILING OR IN WALL GROUND OR GROUND ROD AS NOTED 0 SCALE: 1/8" = V-0" 1� N 9 3A NORTH GENERAL NOTES: 1. ALL FIXTURES TYPE "A" UNLESS OTHERWISE NOTED, 2. CONNECT EXIT AND EMERGENCY LIGHTS TO LOCAL CIRCUITS AHEAD OF SWITCHING. B­: F F 2-#10,#12G 2-4TO,#12G DETAILING AREA 200 rw I 2 4m, '14-1 B-27 VIA PHOTOCELL D %WW B WASHER s Tcl F DETAIL B-21 IGH DRYER A, 64 TL I—P-EM 11111 HO 11111112-011 'vjLLLLLgjlj_____f 1 3 SERVICE SINK WASHER WT, o E, � � m CD � � � � � CU � o CD CD � Di CD � UL. SYSTEM #WL1001 F RATINGS-1,2'3'AND 4 HR (SEE ITEMS 2 AND 3) T RATINGC-0/1,2,3 AND 4 AR (SEE [TEN 3) A Uhl (r\ A SECTION A --A 1. Wall Assembly — The 1, 2, J or 4 hr fire —rated gypsum wallboard/stud *oU assembly shall be oonohuoind of the materials and in the manner described in the individual U300 or U400 3odms Wall or Partition Designs in the UL Fire Resistance Directory and ehqU include the foUowinq construction features: A. Studs — Wo)| framing mny consist of either wood studs (max 2 hr fire rated assemblies) or uto*| channel studs. Wood studs to consist of nom 2 by 4 in. lumber spuooJ 16 in. UC with nom 2 by 4 in. lumber end plates and cross braces. Steel studs to be min 3-5/8 in. v!do by 1-3/8 in. deep channels vp000d max 24 in. 0C. B. Wallboard Gypsum * — Nonn 1/2 or 5/8 in. thick, 4 fL wide with square or tapered edges. The wallboard type, thiokneua, number of layers, /ooteoor type and sheet orientation ahu|1 be as specified in the individual 1/300 or U400 Series Design in the UL Fire Resistance Dirontory. Max d|orn of opening is 13-1/2 in. 2. Pipe or Conduit — Nom 12 in. dium or smaller) S,hodv|, }U (', smaller)heavier) steel pipe, nom 6 in. -diarn (or steel tubingconduit, nom 4" diam (or smaller) steel electrical metallic or Theavier)_copper tubing or '_m 1 in. —_m (or smaller) flexible steel conduit. 'When Uax8do steel conduit is used, max F Rating of Orook` system (Itmn 3) Is 2 h. Steel pipes of conduits |urg°r than nvm 4 in. dinm may only be used in woUs c01­13t'ooted uSing steel channel studs. A max of one pipe or conduit is permitted in the fireatup system. Pipe o, conduit to be ioatoHod near center of stud cavity width and to be rigidly supported on both sides of wu|| assembly. 3. F0, Void or Cavity Materials* — Caulk — Caulk 0|| material installed to completely h!| annular space between pipe or conduit and gypsum wallboard and with o min 1/4 in. dium bead of caulk applied to perimeter of pipe or conduit at its ngronu from the noU. Caulk hnutoUod symmetrically on both a!dma o/ wall assembly. The hourly F Rating of the 8rostop system is dependent upon the hourly fire rating o/ the wall omnomb|y in which it is installed, ua shown in the following table. The hourly T Rating of the fkoo\op system is dependent upon the type or a|zo of the pipe or conduit and the hourly fire ,nting of the wall assembly in which it is installed, as tabulated below: Max Pipe or Annular F T Conduit Space, Rntinq, R"Unq. D|om` In In H/ ik 1 O to 1 o/ 2 0+' 1 or 2 1 1/4 to 1 3 or 4 3 or 4 4 0 to 1 1 or 2 O S 1 to 1/2 3 or 4 0 12 3/18 to 3/8 1 or 2 O + When copper pipe is used, T rating is 0 h. * Bearing the UL C|ooaiUout|on Marking POWER, A N NORTH W 17- IWI& U]E_ ' _(S) — j jrE.) om —PROPOSED SERVICE LOCATION c-5 m c-) a: c_ CID C DJ f U) C7 m co m i m w zo .p L0 to CD cn m Lo 0 ca a w ry C7 C� L.0 rn ra n r cJ x> c-a cn r r A SECTION 16010 - ELECTRICAL GENERAL PROVISIONS 1, ALL WORK AND EQUIPMENT SHALL BE IN COMPLIANCE WITH THE FOLLOWING CODES AND STANDARDS: A. NFPA-101, LIFE SAFETY CODE, B. NFPA-70 (2002), NATIONAL ELECTRICAL CODE C. FLORIDA MECHANICAL CODE (2002) D. FLORIDA BUILDING CODE (2002). E. AMERICANS WITH DISABILITIES ACT (1992). 2. ALL MATERIALS SHALL BE NEW AND FREE FROM DEFECT, EXCEPT WHERE SPECIFICALLY NOTED ON THE PLANS TO BE RECONNECTED OR REUSED. 3. ALL SYSTEMS SHALL BE TESTED FOR PERFORMANCE VERIFICATION IN THE PRESENCE OF THE OWNER AT COMPLETION OF PROJECT. 4. VISIT THE ,JOBSITE PRIOR TO BID AN EXAMINE THE EXISTING CONDITIONS INCLUDE ALL MATERIAL AND LABOR FOR A COMPLETE INSTALLATION. SECTION 16050 - BASIC MATERIALS AND METHODS 1 ELECTRICAL CONNECTIONS TO EQUIPMENT A PROVIDE POWER CIRCUIT WIRING FOR ALL EQUIPMENT REQUIRING ELECTRICAL POWER AND CONNECT COMPLETE UNLESS OTHERWISE INDICATED IN THE CONTRACT DOCUMENTS. B MOTOR HORSEPOWER AND EQUIPMENT SIZES SHOWN AND/OR SPECIFIED ARE ESTIMATED AND SIZE OF WIRE, CONDUIT AND CIRCUIT PROTECTION DEVICES ARE BASED ON SAID ESTIMATE. ASCERTAIN THE ACTUAL HORSEPOWER AND CURRENT REQUIREMENTS, OF THE MOTORS AND EQUIPMENT TO BE INSTALLED, PRIOR TO BEGINNING INSTALLATIONS OF FEEDERS FOR SAME. IF THE ACTUAL REQUIREMENTS ARE DIFFERENT, NOTIFY THE ENGINEER TO OBTAIN CLARIFICATION. C BALANCING ELECTRICAL LOAD: EXERCISE CARE IN CONNECTING THE VARIOUS ELECTRICAL LOADS TO THE PANELS IN ORDER TO ARRIVE AT A REASONABLE BALANCE BETWEEN LOADS IN EACH PHASE AT EACH PANEL. MAKE TESTS AND ADJUST LOADS AT EACH PANEL TO RESULT IN A REASONABLY BALANCED LOAD CONDITION, SATISFACTORY TO THE UTILITY COMPANY, ENGINEER, OWNER AND INSPECTION AGENCIES, 2 WIRE AND CABLE - 600 VOLT A CONDUCTORS: 98% CONDUCTIVITY, SOFT DRAWN COPPER. B INSULATION: HEAT AND MOISTURE RESISTANT, THHN/THWN 600-VOLT RATING C..USE STRANDED CONDUCTOR ON ALL WIRING #6 AWG AND LARGER. ALL OTHER WIRING MAY BE SOLID, 3 WIRING DEVICES A PROVIDE SWITCHES AND RECEPTACLES AS MANUFACTURED BY HUBBELL, PASS & SEYMOUR, LEVITON, ARROW -HART OR GENERAL ELECTRIC. B DUPLEX RECEPTACLES: 20 AMP, 120 VOLT, HEAVY DUTY, COMMERCIAL GRADE, GROUNDING TYPE MEETING THE REQUIREMENTS OF FED. SPEC. WC-596, NEMA WD-1, AND UL-498. C LIGHT SWITCHES: 20 AMP, 120/277 VOLT, HEAVY DUTY, COMMERCIAL GRADE, QUIET TYPE MEETING THE REQUIREMENTS OF FED. SPEC. WS-896 AND NEMA WD-1. D USE SMOOTH STYLE, 0.10" THICK, PHENOLIC OR UREA PLASTIC PLATES. MATCH COLOR OF PLATE WITH COLOR OF DEVICE. PROVIDE PLATES FOR ALL SWITCHES, RECEPTACLES, TELEPHONES AND ALL UNUSED JUNCTION BOXES. E ALL DEVICES SHALL BE DECOR STYLE, WHITE. 4 GENERAL REQUIREMENTS A USE GOOD WORKMANSHIP IN THE INSTALLATION OF ALL ELECTRICAL MATERIALS AND EQUIPMENT. INSTALL EQUIPMENT LEVEL, PLUMB AND TRUE WITH THE STRUCTURE AND OTHER EQUIPMENT. FIRMLY SECURE ALL MATERIALS IN PLACE AND ADEQUATELY SUPPORTED AND PERMANENT, MATERIALS EMBEDDED IN CONCRETE OR MASONRY OR OTHERWISE PART OF THE STRUCTURE ARE CONSIDERED SUFFIC-IENTLY SUPPORTED. USE HARDWARE AND ACCESSORY FITTINGS OF A TYPE DESIGNED, INTENDED AND APPROPRIATE FOR THE USE AND COMPLEMENT THE ITEMS WITH WHICH THEY ARE USED. 5 MINIMUM SIZES A CONDUIT: 3/4" FOR SWITCH LEGS AND BRANCH CIRCUITS. 3/4"FOR ALL HOMERUNS UNLESS OTHERWISE INDICATED. B WIRE: #12 AWG FOR ALL POWER AND LIGHTING CIRCUITS. SIGNAL AND CONTROL WIRING MAY BE SMALLER, AS INDICATED. #10 AWC FOR ALL HOMERUNS UNLESS OTHERWISE INDICATED 6 WIRING METHODS A INSTALL ALL WIRING IN CONDUIT OR APPROVED RACEWAYS UNLESS OTHERWISE INDICATED. CONCEAL THE CONDUIT AND OUTLET INSTALLATION IN WALLS, ABOVE FINISHED CEILINGS, UNDERGROUND OR UNDER FLOOR AS SHOWN ON DRAWINGS. CONDUITS MAY BE RUN EXPOSED ON WALLS AND CEILINGS OF ELECTRICAL ROOMS, MECHANICAL ROOMS, AND/OR OTHER LOCATIONS AS INDICATED. B UNLESS OTHERWISE INDICATED ON THE DRAWINGS OR IN THE SPECIFICATIONS, PROVIDE CONDUIT IN ACCORDANCE WITH THE FOLLOWING: RIGID METAL CONDUIT (RMC): ANYWHERE EXCEPT CORROSIVE ENVIRONMEN I S INTERMEDIATE METAL (IMC): ANYWHERE EXCEPT CORROSIVE ENVIRONMI ITS THINWALL METAL (EMT): ANYWHERE EXCEPT AS FOLLOWS: UNDERGROUND. IN SLABS ON GRADE. CORROSIVE ENVIRONMENTS. SCHEDULE 40 AND 80 PVC: UNDERGROUND ONLY, C�E'3 SIVE ENVIRONMENTS: USE RMC ORlll�COATEDINACCORDANCE WITH 00-6 C USE FLEXIBLE STEEL CONDUIT WITH GROUND WIRE FOR FINAL CONNECTION TO MOTORS AND LIGHT FIXTURES. USE SEALTITE IN DAMP OR CORROSIVE ATMOSPHERES, D DO NOT PULL CONDUCTORS INTO CONDUITS UNTIL ALL WORK WHICH MAY CAUSE DAMAGE TO THE WIRES IS COMPLETED. INSTALL WIRE AND CABLES SO AS NOT TO DAMAGE THE INSULATION OR CABLE SHEATH. PULL ALL CONDUCTORS TO BE INSTALLED IN A RACEWAY TOGETHER. TRAIN AND GUIDE WIRES INTO THE RACEWAY USING A PULLING COMPOUND OR LUBRICANT WHEN NECESSARY. PROVIDE A MEANS OF COMMUNICATION BETWEEN THE PULLING AND GUIDING POINTS TO FACILITATE INSTALLATION AND TO HELP PREVENT DAMAGE, USE A PULLING MEANS THAT WILL NOT DAMAGE THE RACEWAY. E KEEP CONDUCTOR SPLICES TO A MINIMUM. PROVIDE SPLICES AND TAPS WITH AT LEAST THE EQUIVALENT MECHANICAL STRENGTH AND INSULATION AS THE CONDUCTORS. PROVIDE SPLICE AND TAP DEVICES OF THE PROPER SIZE AND TYPE FOR THE USE AND COMPATIBLE WITH THE CONDUCTOR MATERIAL. ALL SPLICES SHALL BE MADE IN JUNCTION BOXES OR TERMINAL CABINETS. NO SPLICES SHALL BE PERMITTED IN CONDUIT(S). 7. EQUIPMENT MOUNTING A INSTALL EQUIPMENT ON CEILING, WALL OR FLOOR AS INDICATED OR AS APPROPRIATE. PROVIDE FASTENERS OR SUPPORTS SUFFICIENT IN SIZE AND QUANTITY TO SUBSTANTIALLY SECURE THE EQUIPMENT IN PLACE TO THE BUILDING STRUCTURE OR STRUCTURAL ELEMENT. B INSTALL THE EQUIPMENT PLUMB, TRUE AS INTENDED AND SECURE. WHEN SEVERAL ITEMS OF EQUIPMENT ARE WALL MOUNTED IN THE SAME AREA, LINE THEM UP VERTICALLY AND HORIZONTALLY ALONG WITH ANY ASSOCIATED RACEWAYS. 8. SLEEVES A WHERE CONDUITS PASS THROUGH SLEEVES IN EXTERIOR WALLS, CAULK THE ANNULAR SPACE WITH OAKUM AND FILL INSIDE AND OUT WITH A NON - HARDENING, WATERPROOF SEALANT FINISHED OFF FLUSH WITH BOTH FACES OF THE WALL SECTION 16195 - ELECTRICAL IDENTIFICATION 1. PROVIDE EACH BRANCH CIRCUIT PANEL WITH A DIRECTORY INDICATING LOADS SERVED. THE PANEL SCHEDULES SHOWN ON THE PLANS DO NOT CONTAIN ADEQUATE INFORMATION TO BE COPIED AND USED AS PANEL DIRECTORIES, LABEL EACH CIRCUIT WITH ACTUAL ROOM NUMBERS OR ROOM NAMES SERVED, SUCH AS "RECPT 109, 110, 111". 2. USE ENGRAVED PLAQUES FOR LABELING LARGE EQUIPMENT. 3. LABEL EACH POWER JUNCTION BOX WITH AN INDELIBLE MARKER INDICATING THE CIRCUIT NUMBERS CONTAINED WITHIN, SECTION 16CO - SERVICE AND DISTRIBUTION 1. PANEL BOARDS SHALL HAVE LOCKING COVERS AND USE BOLT -ON CIRCUIT BREAKERS. DESIGN BASIS IS SQUARE-D QOB OR EQUAL. PROVIDE SHORT CIRCUIT RATINGS AS INDICATED ON THE PLANS, 2. DISCONNECTS FOR U.L. LISTED EQUIPMENT SHALL BE MATCHED TO THE NAMEPLATE REQUIREMENTS OF THE EQUIPMENT AS SUBMITTED BY THE MECHANICAL CONTRACTOR. IT IS UNDERSTOOD THAT MANY KINDS OF DESIGN CHANGES, VALUE ENGINEERING CHANGES, AND BRAND NAME SHOPPING OCCUR BETWEEN THE TIME THESE PLANS ARE MADE AND THE TIME OF FINAL EQUIPMENT PURCHASE. VERIFY FINAL EQUIPMENT RATINGS WITH SUBMITTALS, 3. IN FUSED SWITCHES, PROVIDE DUAL -ELEMENT FUSES SIZED PER EQUIPMENT NAMEPLATES, 4. TOGGLE TYPE SWITCHES MAY BE USED AS DISCONNECTS WHERE SHOWN ON THE PLANS. PROVIDE PROVISIONS FOR LOCK -OUT. SECTION 16450 - GROUNDING 1. PROVIDE GROUND CONDUTORS IN ALL CONDUITS. 2. PROVIDE GROUNDING BUSHINGS FOR FEEDER CONDUITS. 3. SERVICE GROUND RESISTANCE SHALL BE MEASURED WITHOUT DEPENDING ON WATER PIPING SYSTEM AND SHALL BE 25 OHMS OR LESS, IF GREATER THAN 25 OHMS, DRIVE ADDITIONAL GROUND RODS TO OBTAIN REQUIRED RESISTANCE. SECTION 16500 - LIGHTING 1. U.L. LABELS MUST APPEAR ON ALL LIGHTING FIXTURES. FLEXIBLE CONDUIT TAILS, UP TO SIX FEET IN LENGTH, MAY BE USED BETWEEN JUNCTION BOXES AND RECESSED LIGHTING FIXTURES. OUTLET BOXES MAY SERVE UP TO FOUR SEPARATELY RECESSED FIXTURES. BALLASTS SHALL BE ELECTRONIC HIGH -POWER FACTOR CBM LABELED. 2. PROVIDE PROPER TRIM PER REFLECTED CEILING PLAN OR ACTUAL CEILING INSTALLED. 3. PROVIDE LAMPS IN ALL FIXTURES, 4, EXIT SIGNS, EMERGENCY BATTERY PACKS AND EMERGENCY INVERTERS SHALL BE CONNECTED TO LOCAL CIRCUITS AHEAD OF SWITCHING, SECTION 16740 - COMMUNICATIONS SYSTEM 1. PROVIDE 3/4"CONDUIT FROM EACH OUTLET TO ACCESSIBLE CEILING SPACE,U.N.O. 2. COORDINATE OUTLET AND STUB -UP LOCATIONS WITH OWNER .3. PROVIDE 3/4"X2'X2' HIGH PLYWOOD BACKBOARD ADJACENT TO ELECTRICAL PANELS PAINT WITH FIREPROOF GREY PAINT. PROVIDE #6 INSULATED COPPER GROUND WIRE FROM BACKBOARD TO SERVICE GROUND. 4 PROVIDE (1) 2"CONDUIT FROM TTB TO PROPERTY LINE, APPROXIMATELY 250. PANEL: VOLTAGE: 120/208/3PH/42 MAIN: 200A MLO MOUNTING: SURFACE A.I.C. 10 KA SERIES RATED SPACES: 42 CIRCUff L AD(AM AMP POLE CIR CIR AMP POLE LAD AM CIRCUIT LABEL A B C CB NO. NO. CB A 6 I C LABEL WfR HTR 38 50 2 1 2 20 2 12 CU 38 3 4 12 FUTURE 44 60 2 5 6 50 2 26 CU COMP 44 7 8 26 SITE LTG 9 20 2 9 10 40 2 1 32 AHU 9 11 12 32 SITE LTG 7 20 3 13 14 60 2 44 AHU 7 1 15 16 44 17 1 18 20 1 12 WASHER 19 20 20 1 16 COMP, 21 22 30 2 24 DRYER 23 24 24 25 26 27 28 29 30 31 32 33 34 35 36 37 138 39 40 41 42 DEMAND LOAD THIS PANEL IS 154 AMPS 187 166 147 TOTAL AHU/CU ARE NON -COINCIDENTAL PANEL: B VOLTAGE: 120/208/3PH/42 MAIN: 200A M.L.O. MOUNTING: SURFACE A.I.C. 10 KA SERIES RATED SPACES: 42 SECTION: 1 OF i CIRCUIT OAD AMP) AMP POLE CIR CIR AMP POLE AD(AMP) CIRCUIT LABEL A B C CB NO, NO. CB A B C LABEL RECPT 10 20 1 1 2 20 1 6 RECPT RECPT 10 20 1 3 4 20 1 6 RECPT RECPT 10 20 1 5 6 20 1 1 6 1 RECPT RECPT 3 20 1 7 8 20 1 6 RECPT RECPT 10 20 1 9 10 20 1 9 RECPT RECPT 10 20 1 11 12 20 1 9 RECPT RECPT 10 20 1 13 14 20 1 8 RECPT LIGHTING 15 20 1 15 16 20 1 5 RECPT LIGHTING 15� 20 1 17 18 20 1 3 RECPT LIGHTING 15 20 1 19 20 20 1 10 RECPT LIGHTING 15 20 1 21 22 20 1 10 RECPT LIGHTING 11 20 1 23 24 20 1 10 RECPT LIGHTING 9 20 1 25 26 20 1 10 RECPT E LT 6 20 1 27 28 20 1 10 RECPT XT. L Gol�A, 20 1 29 30 20 1 -10-1 RECPT SPKRS 2 2 1 32 20 1 10 RECPT SPARE 20 1 33 V434 20 1 10 RECPT FAN 17 25 1 35 36 20 1 10 IRECPT FAN 17 1 25 1 37 38 20 1 10 RECPT FAN 17 25 1 39 40 20 1 10 RECPT FAN 17 25 1 41 42 20 1 10 RECPT DEMAND LOAD THIS PANEL IS 102 AMPS 126 133 142 TOTAL A v 600 AMP K-RATE PWR C METER n :NEW(/ N T24CED UNDERGROUND (D TO POWER CO. �w TRANSFORMER PANEL A I f � I PANEL B I ) (PANEL SL 4nAMP NEW UGHTNINO ARRESTOR 6 TYP. OF 3. TSO. OPANEL B DISC. PROVIDE LABELING 200 AMP NEW 10"X10'X4' N3R WIREWAY SERVICE RISER DIAGRAM SCALE: NONE REFERENCED ELECTRICAL NOTES: Q 1 NEW UNDERGROUND SECONDARIES TO POWER CO. PAD MTD TRANSFORMER. COORDINATE WITH POWER CO. 2 SETS OF 4-250 CU IN 3"C. EXTEND CONDUCTORS ENTIRE LENGTH OF WIREWAY. INCLUDE 220 LINEAR FEET OF SECONDARIES IN BID. INCLUDE TRENCHING AND BACKFILL. 2 2 SETS OF 4-3/0 CU AND 2/0 CU GRND IN 3"C. A23 NEW 3/0 GROUNDING ELECTRODE SYSTEM. TIE TO 2 (2) 20' GROUND RODS, BUILDING FOUNDATION STEEL N LD T I C54 4-1/0 CU AND #16 CU GRND IN 1-1/2"0. 200/3/F/N3R/240V DISC. FUSE AT 150 AMPS. 4- 0 R IN C. 7 200/3/F/N3R/240V DISC. FUSE AT 200 AMPS 8 NEW RAINTITE WIREWAY. SEAL ALL PENETRATIONS. WIREWAY TO HAVE SCREW COVER. GENERAL NOTES: 1. ALL WIRE TO BE THHN/THWN COPPER UNLESS OTHERWISE NOTED CONTRACTOR MAY PROVIDE AN ALTERNATE FOR ALUMINUM, SIZES ALLOWED BY LOCAL CODE. 2. PROVIDE LUGS AND ALL EQUIPMENT TO PROPERLY CONNECT ALL WIRES. 3. SERVICE VOLTAGE IS 120/208V, 3 PHASE, 4 WIRE, DEMAND SERVICE LOAD IS 381 AMPS, DESIGNED SERVICE SIZE IS 500 AMPS. 4. METER WITHSTAND RATINGS SHALL BE 10,000 AMPS MIN. IF METER IS PROVIDED BY CONTRACTOR. TYPE LAMPS DESCRIPTION MANUFACTURER / CATALOG NUMBER SEE NO TYPE NOTE A 3 132T8 214 ACRYLIC LENSED LAY -IN LIGHTOLIER XT2GVA332120-SO-03 1,2 B 1 250WMH HIGH -BAY WITH ACRYLIC REFRACTOR EXCELINE BYC16--250MA 1 AND CONICAL LENSE BE SAME AS "B" EXCEPT WITH QUARTZ EXCELINE BYC16-25OMA-Q16 1 RESTRIKE C 2 42WTIT RECESSED FLUORESCENT LIGHTOLIER 8O89CLW/8242HG120 1,2 8" OPEN, CLEAR ALZAK D 1 70MH EXTERIOR WALL MOUNT EXCELINE PCS-7-3-MA-4-120 1,3 COATED F 2 F32T8 1X4 FLANGED FLUORESCENT LIGHTOLIER XTIFVA240SO 1,2 ACRYLIC LENSE EM 2 9 WATT EMERGENCY BATTERY LIGHTOLIER E5-W 1 TUNGSTEN UNIT -HIGH INTENSITY EMA 2 12 WATT EMERGENCY BATTERY LIGHTOLIER E2172LH12W 1 HALOGEN UNIT -HIGH INTENSITY X LED EXIT SIGN WITH LIGHTOLIER LLNURW 1 BATTERY PACK NOTES: 1. FIXTURES BY LITHONIA, GENLYTE ANDTHOMAS ONLY ARE PRIOR APPROVED. 2. ALL FLUORESCENTS TO HAVE ELECTRONIC BALLASTS ZN O PLUMBING KEY NOTES & SCHEDULE: Pl: 2" GATE VALVE IN BROOKS BOX LA13ELED YfkTW_ P2: FOR CONTINUATION SEE CIVIL UTILITIES PLAN. P3: 2000 GALLON PRECAST, CONCRETE ,IN -GROUND SAND/OIL INTERCEPTOR. SEE DETAIL. P4: 1/2" CW DOWN TO BALL VALVE. HOSE, HOSE REEL AND APPURTENANCES BY OWNER. SEE ARCHITECTURAL PLANS FOR MOUNTING HEIGHT. L-1: WHITE COUNTERTOP 19"VITREOU5 CHINA LAVATORY. AMERICAN STANDARD 0491.019 OR EQUAL. PROVIDE AMERICAN STANDARD 2385.404 CP SINGLE LEV. FAUCET. MCGUIRE GRID DRAIN AND P TRAP. 0.5" CW. 0.5" HW. 1.5" TRAP. L-2: WHITE HANDICAPPED ACCESSIBLE WALL HUNG VITREOUS CHINA LAVATORY. AMERICAN STANDARD 0355.012 OR EQUAL, PROVIDE WALL CARRIER. PROVIDE AMERICAN STANDARD 2385.404 CP SINGLE LEV. FAUCET. MCGUIRE OFFSET GRID DRAIN AND P TRAP. ADA TRAP WRAP MITE INSULATION KIT. 0.5" CW. 0.5" HW. 1.5"TRAP. WC-1: HANDICAPPED ACCESSIBLE WHITE FLOOR MOUNTED ELONGATED TANK TYPE WATER CLOSET. AMERICAN STANDARD CADET OR EQUAL. (1.6 GALLONS PER FLUSH). PROVIDE WHITE OPEN FRONT ADA SEAT OLSONITE 95 OR EQUAL. 0.5" CW. INTEGRAL TRAP. 4" SAN. UR-1 ' WHITE WALL HUNG URINAL EQUAL TO AMERICAN STANDARD 6501 .010. PROVIDE WALL CARRIER. PROVIDE FLUSH VALVE EQUAL TO SLOAN 186YB. 3/4" CW. INTEGRAL TRAP. 3" SAN. UR-2: SAME AS UR-1 WITH ADA MOUNTING HEIGHT. FDA: 4" OUTLET PARKING DECK / VEHICALE RATED FLOOR DRAIN WITH SUPPORT FLANGE, DEEP SEAL P TRAP, 9- DIAMETER STRAINER AND CAST IRON BODY. ZURN Z533 OR EQUAL. 4" TRAP. T!SCALE L NORTH fi Af/ ly FD, TYP OF TARP X/ P AND SuppogfiNG hl JCTURE BY OWNER) 1INT �E h/ 0 i ul TYPICAL DETAIL BAY PACKAGE: BALL VALVE AT 36" AFF ELECTRICAL AT 42" AFF SCALE 1/4" = V-0" 0 A C-) 11 0 PLUMBING KEY NOTES & SCHEDULE: Pl: 2" GATE VALVE IN BROOKS BOX LABELED WATE] P2: FOR CONTINUATION SEE CIVIL UTILITIES PLAN. P3: 2000 GALLON PRECAST, CONCRETE, IN -GROUND SAND/OIL INTERCEPTOR. SEE DETAIL. P4: 112'CW DOWN TO SALL VALVE. HOSE, HOSE PEEL AND APPURTENANCES BY OWNER. SEE ARCHITECTURAL PLANS FOR MOUNTING HEIGHT. L-1: WHITE COUNTERTOP ig" VITREOUS CHINA LAVATORY. AMERICAN STANDARD 0491.019 OR EQUAL. PROVIDE AMERICAN STANDARD 2385.404 CP SINGLE LEV. FAUCET. MCGUIRE GRID DRAIN AND P TRAP. 0.6" CW. 0.5" HW. 1.5" TRAP. ........... UR-1: WHITE WALL HUNG URINAL EQUAL TO AMERICAN STANDARD 6501.010. PROVIDE WALL CARRIER. PROVIDE FLUSH VALVE EQUAL TO SLOAN 186YB. 3/4" CW. INTEGRAL TRAP. UR-2: SAME AS UR-1 WITH ADA MOUNTING HEIGHT. FDA: 4" OUTLET PARKING DECK / VEHICALE RATED FLOOR DRAIN W14W FD-2: 3"OUTLET FLOOR DRAIN WITH TRAP PRIMER CONNECTION, 5" DIA. STRAINER AND CAST IRON BODY. ZURN Z415PNL OR EQUAL. 3" TRAP. THERMOPLASTIC 24"X 24"X 10" HIGH MOP SINK EQUAL TO FIAT MSI3242,. PROVIDE WITH SPEAKMAN SC-581 I -RCP SERVICE FAUCET AND WALL BRACE AND VACUUM BREAKER. 0.5" CW. 0.5" HW. 3" TRAP. S-1: TWO COMPARTMENT COUNTERTOP STAINLESS STEEL SINK EQUAL TO DAYTON D3322-3. PROVIDE FAUCET EQUAL TO MOEN T7124. PROVIDE STRAINER, P TRAP AND ANGLE STOPS. 0.5" CW. 1.5" HW. 1.5"TRAP. ICE-1: RECESSED THERMOPLASTIC WALL BOX WITH VALVE FOR IC MAKER IN REFRIGERATOR. OATEY, GUY GREY OR EQUAL. WMB-1: RESIDENTIAL WASHING MACHINE BOX WITH INTEGRAL CW AND HW ISOLATION VALVES AND DRAINAGE PORT. PROVIDE WITH ALL HOSES AND VACUUM BREAKERS. WHA: 50 GALLON ELECTRIC WATER HEATER WITH HEAT TRAPS. VAC. SINGLE PHASE, DUAL 4.0 KW SIMULTANEOUS ELEMENTS (8KW AT RATED VOLTAGE). RUUD PE-52-2 OR EQUAL, EXTERNAL JUNCTION BOX REQUIRED AND FURNISHED BY ELECTRICAL TRADE. PROVIDE 18" HIGH CAST IRON STAND, APPROVED PAN, T/P RELIEF VALVE, WATTS EXPANSION VALVE AND TANK DRAIN VALVE, 0.75" CW. 0.75" HW. 4" co 3 )? VTR 1161031011111111 omo 4" CO AIR COMPRESSOR PAD 211 IN, A rlqtzi DEET a ILI" do" ARE A ur"'Lumts G PLAN SCALE 1/8 NORTH 4" CO HB-1 W/ BALL VALVE HB-1 W/ BALL VALVE 3" VTR 4" CO EWH-1 MS-1 2" VTR 3" COTG 2" COTG yy GQTG r�r A,1 �f ny 1: VERIFY ALL EXISTING CONDITIONS AND EXACT LOCATIONS OF ALL EQUIPMENT TO BE PLUMBED PRIOR TO COMMENCEMENT OF WORK. ' P 2. COMPLETE AND WORKING PLUMBING SYSTEMS SHALL BE IN ACCORDANCE WITH THE 2001 FLORIDA PLUMBING CODE AND }�L AUTHORITY HAVING JURISDICTION. (AHJ) P 3. PRESSURE AND HYDROSTATICALLY TEST THE NON COMPRESSED I + Go, AIR PIPING, AS APPLICABLE, TO INSURE THE ABSCENCE OF LEAKS IN ACCORDANCE WITH THE 2001 FLORIDA BUILDINGIPLUMBING CODE. DISINFECT ALL DOMESTIC WATER PIPING IN ACCORDANCE WITH THE 2001 FLORIDA BUILDING/PLUMBINGCODE. 4. NEW WASTE DRAIN AND VENT PIPING SHALL BE PVC DWV. TRENCHES SHALL BE BACKFILLED ARID COMPACTED. NEW CW, HW AND TIP RELIEF PIPING SHALL BE TYPE L COPPER WITH WROT FITTINGS AND SILVER SOLDER OR 05/5 TIN ANTIMONY. WRAP NEW HOT WATER PIPING WITH 1" R-4 PER. INCH (PER THE 2001 FLORIDA MODEL ENERGY CODE) CELLULAR RUBBER INSULATION EQUAL TO ARM STRONG ARMAFLEX, NOTE: BRANCH PIPING LESS THAN 12' MAY BE INSULATED WITH 112" INSULATION PER SAME CODE. FIBERGLASS INSULATION MAY BE SUBSTITUTED WITH EQUAL R VALUE. ALL DOMESTIC WATER BALL VALVES SHALL BE 2 PIECE BRONZE 150 PSI WOG DATED. 5. SECURE ALL REQUIRED PERMITS ARID PAY ALL ASSOICATED FEES. 6. SEE CIVIL / SITE PLANS FOR LOCATION OF SITE LOCATED DOMESTIC WATER BACKFLOW PREVENTER. e P. 7. PROVIDE WATER HAMMER ARRESTORS IN ACCORDANCE WITH THE 2001 FLORIDA BUILDINGIPLUMBING CODE AND PDL HIGHWAY RATED MANWAYS RISER SEGMENTS TO GRADE 6" RUBBER BOOT TYP., UNLESS NOTED OTHERWISE — --- Q> d- PLAN VIEW VAC RELIEF VALVE. MIN. 6" F ABOVE TAT. THERMOMETER /AY RATED AYS Y 1IflLE THRU BAFFLE USF 117 OR USF 170 R/C C� I OLDS CASTLE PRECAST CONCRETE OR EQUAL v � � <, T/P RELIEF VALVE, a STORAGE AT 1110 $ F DETAILING AREA WASTE VENIP RISERr PAN � NOT TO SCALE DRAIN VALVE FULL SIZE TO MOP SINK 4 WATER HEA91PER DETAIL 6 NOT TO SCALE L> W, I 6 rj �)4 TYR rV- —al- %x TYR fo DETAILING AREA DOMESTIC WATER RISER SCALE: N.T.S. Nl' 7z m VD c-� oz SCALE: N.T.S. I I� ,o 0 �9 1p I 1 � OFFICE AREA DOMESTIC WATER RISER 1 I 1%2 SCALE: N.T.S. ljL 1.5" VTR ILJA S-1 OFFICE AREA - WASTE & VENT RISER ,s SCALE: 4 15 4" 2-WAY COTE 4 49 VTR s�� G 1.5�9 9 /AY COTG r � 4 ,�: ,��t? �ill�, �• I�i;tMlllHi�J�^, ____�_____� ____._._--.__.__�_.�__,�.ar,_�� �o �. 4