101, 111 and 201 Towne Center Cir 95-2772, 95-2773, 95-2774 Upper Level Mall
• �. 12rX16Y TENANT s, ,. DUCT 6 PD 12 r" ;VAV-6 x14 °x14" _ ; 1600 CFM " 7 PROJ._NO. SCALE r. DATE: DRAWN -BY, CHECKED -BYr _. €E f uR' i,. Y. t 9t 'I m 4 tl w,' . 4 SHEET N0. . n I n 'K A n N ',TYFICALRECEPTACLE Ou M W L L NfED 5TAND RG • R -)N�BOX��#T IN *,E ED.jUNC-TIC MALI-' 61bF -m.Ft' PROVIDE UKIR6 PER TENANT'6 6PECV&AtltiON*6-�-,��I'� W �R�oom- N 7 GPT(CON RACTOR e WALL NOU f TEb EXIT L UBMIT TAL • NG 6TANDAR ECE65 WALL E�U I L r-> I -3: p. 0'T 15W PAR :30 0 'o • L�Ax45 6F cul • E' IFE ENGINr.�Ef� EC) Fl - X T RE=,LAYOUT'-- u 0= COLITE' 6USPENDEDII E.-:T CTOR� TO: 0 EC ION INATE'F FOR 'TRACk 5' CRC#Z -F a. DES"AT IN SAME-A8�VE. WITWTVE� 3 -l'Wr TRACK� O� �BE N C;ONNtc;roR5)'WITHjV 500 1 0 F 1. CONSTRUCTION. WATER RISER 6. REQUIRED INSURANCE SHALL BE ` PROVIDED BY THE CONTRACTOR NO SCAs FOR PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR DURATION OF WORK. 7. ' CONTRACTOR SHALL SECURE AND PAY ALL ', PERMITS, FEES, - BUILDING SANITARY SEWER - ' INSPECTIONS AND TESTS. TENANT CONNECTION - VENT 8. DRAWINGS ARE DIAGRAMMATIC, DO NOT SCALE FOR THE —EXACT LOCATION OF FIXTURES, PIPING, EQUIPMENT, ETC.. 9. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION. ' , yr VENT \ I 10. VERIFY. LOCATION, SIZE, INVERTS .AND ALL EXISTING UTILITIES PRIOR TO BEGINNING CONSTRUCTION. ADVISE'' ENGINEER OF ANY DISCREPANCIES. u .:- 1 1 . WATER PIPING SHALL BE TYPE L" COPPER. Hwc rr ,' °y. 12. INSULATE ALL" HOT WATER LINES WITH — 1" THICK FIBERGLASS, 13. ALL FIXTURES MUST BE PROVIDED WITH READILY ACCESSIBLE SANITARY ISOMETRIC i CONTROL VALVES AND ACCESS PANELS.: NO Solis 14. DIELECTRIC' COUPLINGS ARE REQUIRED BETWEEN ALL .;.'; DISSIMILAR METAL IN PIPING AND EQUIPMENT CONNECTIONS. - ik x }; = 15. ISOLATE COPPER PIPE FROM HANGER OR SUPPORTS ,.WITH ISOLATOR PAD (HAIR FELT LINING) SUPER :STRUT MODEL C/15/1 6. � (� t ^ FIRE PROTECTION SPRINKLER WORK— GENERAL NOTES — FILL VOIDS BETWEEN PIPE & WALL FLOOR SLEEVES WITH FIRE RATED / FIRE, SPRINKLER CONTRACTOR SHALL STUDY ARCHITECTURAL AND OTHER RELATED s. FOAM. — — — — CONSTRUCTION. DRAWINGS AND VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO CONST CT 16. CONTRACTOR SHALL GUARANTEE ALL MATERIAL'S' & WORKMANSHIP CONTRACTOR IS RESPONSIBLE FOR ALL APPLICABLE 'FEES AND PERMITS. FREE FROM DEFECTS FOR A PERIOD OF NOT LESS THAN ONE. (1) YEAR FROM DATE OF ACCEPTANCE. CORRECTION OF ANY DEFECTS SHALL BE TENANT CONNECTION CONTRACTOR SHALL SUBMIT HYDRAULIC CALCULATIONS IF NECESSARY. 4M, I COMPLETED WITHOUT ADDITIONAL CHARGE AND SHALL INCLUDE REPLACEMENT OF REPAIR OF ANY OTHER PHASE OF THE INSTALLATION CONTRACTOR SHALL FURNISH ENGINEERS SEALED DRAWINGS -AND LETTER } WHICH MAY HAVE BEEN DAMAGED. INDICATING I. S. 0. OF FLORIDA'S ACCEPTABLE RATING. 17. PROVIDE ACCESS PANELS FOR ALL CONCEALED :VALVES, ACCESS THE PROTECTOR SYSTEM SHALL MEET ALL STATE AND LOCAL I CODE , C PANELS IN RATED WALLS MUST MAINTAIN THE SAME RATION. ALL ACCESS PANELS MUST MATCH THE FINISH OF THE WALL IN WHICH IT REGULLATIONS AND ORDINANCE IS INSTALLED. THE LATEST EDITION OF NATIONAL FIRE PROTECTION A SSOCIATION — BULLETIN NO 13 SHALL BE THE MINUMUM REQUIREMTNT FOR ALL WORK =. 18. NO WATER, SANITARY OR DRAINAGE PIPING PERMITTED IN . , AND PRESSURE TESTING. ELECTRICAL EQUIPMENT ROOMS. t ALL PIPING SHALL BE INSTALLED TO DRAIN BACK RISER. 19. SOIL, WASTE, AND VENT PIPING SHALL BE: CAST IRON. PF11-2 ESCUTCHEON PLATES ON SPRINKLER HEADS IN FINISHED CEILINGS SHALL 20. ,ALL HOT WATER PIPES UNDER SINKS SHALL BE WRAPPED AND r CHROME. BE : INSULATED WITH HANDI—SHIELD WRAP OR EQUAL. SPRINKLER SPACING SHALL NOT EXCEED 130SFT PER HEAD IN SUSPENDED CEILING OR 100 SFT PER HEAD IN EXPOSED ROOF AREA. 21. PROVIDE 2 SETS OF OPERATION' AND MAINTENANCE MANUALS TO BUILDING OWNER AT COMPLETION OF JOB. „ VENT ! INSTALL STANDARD CHROME HEADS AND CONCEALED SPINKLER PIPING IN AREAS HAVING FINISHED CEILINGS AND UPRIGHT BRASS HEADS ON FIXTURE SCHEDULE EXPOSED PIPING IN EXPOSED ROOF AREAS. INSTALL TEES AND PLUGS AT CHANGES IN - DIRECTION AND AT THE END WC-1 HANDICAP WATERCLOSET AMERICAN 2216 -143 OF ALL LINES, TO FACILITATE THE REMODELING OF THE SYSTEM. s - SPRINKLER HEADS ARE TO BE FLUSH MOUNTED AND OF THE ON —OFF DESIGN L-1 HANDICAP LAVATORY WALL HUNG WHITE AMERICAN 03560-015 (USE GRINNELL AQUAMATIC OR EQUAL) OVAL AS FOLLOWS DETAIL SHOP DRAWINGS SHALL BE SUBMITTED FOR APPROVAL (A) INSURANCE SERVICES OFFICE OF FLORIDA. DF B. BUILDING AND FIRE DEPARTMENT OF SEMINOLE COUNTY. - (C) ARCHITECTS/ ENGINEERS. ! x , , ^k ,u .r. , f ' ♦.' r r " r � !L' REVISION, �. Al 44 PROJ._NO. SCALE DATE DRAWN -BY r CHI CKCED—BY , , I ! t Fax 407-876-0885 SHEET N0. I ' Iz G ♦ t' .. _..ern R k� ASAP . , t 1 I�� 19 "—. �� .,.:.:.— i -Sri"%—r tirsm. .x•k: •5•,-.. '_ .. -.. -. _.,. ".4p .:. _ — - - .. - .. _... --_ - _ _ _. PANEL SCHEDULE P F -1 1 VO 1 MMLO MB AMOPS S FF 12 208 20 3 4 000 CKT DESCRIPTION WIRE TRIP CKT I DESCRIPTION WIRE TRIP 1 RECEPTICLES 12 20 2 RECETICLES 12 20 3 RECEPTICLES 12 20 4 RECETICLES 12 20 5 WATR HEAT RE 8 30 6 VAV CONTROL 12 20 7 WATR HEATERE 8 30 8 VAV CONTROL 12 20 9 LIGHTING 12 20 10 NIGHT LIGHT 12 20 11 SPARE 12 LIGHTING 12 20 13 14 SPARE 15 16 17 18 1 20 21 22 23 24 u�----------------- VAV PF1 1 -3 PF1 1 —7 s PF1 1-4 o � � TRANSFORMER TF-11 MOUNTED ABOVE PF1 1T517 CEILING. PROVIDE ALL HARDWARE a , a 3 1 i f, I Cuhaci & "Peterson Architects, '-Inc. 200 E. Robinson St. I Suite 400 Orlando, Florida 32801-1955 Ph. 407 422 °-4070 Fax. 407 839 0832 s III ) PROJ._NO. SCALE 1 DATE: I' DRAWN —BY �i CHECKED —BY. � SHEET NO. 4 u HT[N G F1 XTU R'E- S C H E D U L.-E u HT[N G F1 XTU R'E- S C H E D U L.-E -MARK LAMP DATA DESCRIPTION FIXTURE MODEL NUMBER. MOUNT VOLT NOTES QTY. TYPE MANUFACTURER CATALOG NUMBER „ A 3 F32T8 2' CX '4' RECESS PARABOLIC FIXTURE PROVIDE BY TENANT REC. GRID 120 B 1 F32T8 4" FLUORESCENT STRIP FIXTURE PROVIDE BY TENANT REC ' GRID 120 C 3 F32T8 2' X 4' RECESS FLUORESCENT LITHONIA SPG232RW— 1 21-25—ES REC GRID 120 TYPE ``'C" EQUAL DAYBRIGHT 2DG332RA-"12—ES" D 2 F32T8 4' INDUSTRIAL" FLUORESCENT LITHONIA REC GRID 120 TYPE " D" EQUAL DAYBRIGHT 1 F-232—PP—ES E 1 HALOGEN INCANDESCENT DOWNLIGHT LITHONIA LICM-'M.CIA RECPLAST 120 TYPE "E" EQUAL CAPRI R4X=R402 F 1 50W/R20 TRACK LIGHTING FIXTURE PRESCOKITE T112—WH TRACK 120 TYPE 4, Fa, EQUAL HALO L1540—P G — — - - — SINGLE -CIRCUIT LIGHTING TRACK PRESCOLITE 2) TS8-WH & 2) TS2—WH SURF 120 5 TYPE "G" EQUAL HALO 2) L652—P_& 2) L650—P X W UNIT SINGLE FACE- EMERGENCY EXIT LITHONIA QMSW3REL UNIVERISAL 120 2,3 TYPE "X" EQUAL EMERGILITE PL—W—SRX—X32—R BU W/ UNIT EMERGENCY BATTERY UNIT LITHONIA 6ELM2 UNIVERSAL 120 2,3,4 TYPE "BU" EQUAL` EMERGILITE JSM18-2 LIGHTING FIXTURE NOTES: 1. GENERAL 'SCHEDULE NOTES (APPLIES TO ALL FIXTURES). A) CONTRACTOR SHALL COORDINATE .FIXTURE MOUNTING WITH ARCHITECTURAL REFLEDC CEILING PLAN(S) AND SHALL PROVIDE FIXTURE MOUNTING AS REQUIRED TO MATCH CEILING TYPE. B) ALL FIXTURES BALLASTS SHALL BE HIGH POWER FACTOR TYPE. C) ALL FLUORESCENT BALLASTS SHALL BE ENERGY SAVING TYPE. 2. FIXTURES TO BE PROVIDED WITH INTEGRAL EMERGENCY BACK—UP. 3. FICTURES SHALL BE CONNECTED TO CONSTANT NORMAL ROOM LIGHTING BRANCH CIRCUIT OF AREA SERVED (i,e, LOAD SIDE OF BREAKER, LINE SIDE OF ANY SWITCHING/CONTROLLING DEVICES. 4. FIXTURE SHALL BE WALL MOUNTED 47' —6" AFF TO TOP. 5. PROVIDE ALL NECESSARY ACCESSORIES AND HARDWARE REQUIRED FOR A COMPLETE INSTALLATION INCLUDING, BUT NOT LIMITED TO, DEAD ENDS, POWER FEEDS, ETC. , r SYMBOLS J� FLOURESCENT LIGHTING FIXTURE -CEILING ' MOUNTED ;;, FLOURESCENT INCANDLESCENT OR HID DOWNLIGHT FIXTURE CLG: MOUNTED �' -• ' TRACK LIGHTING FIXTURE - CLG. MOUNTED EMERGENCY BATTERY -EXIT LIGHTING FIXTURE UNIT y i� EMERGENCY BATTERY UNIT LIGHTING FIXTURE — WALL MOUNTED b b,` CUhaci & Reerson t [ . fl: Architects; Inc. {{ SINGLE POLE TOGGLE SWITCH - MOUNTED 42 AFF TO E; CENTERLINE UNLESS OTHERWISE NOTED. (3) _, 3WAY 200 E. RobinsonSt.' Suite 400 I Orlando, Florida'.32801-1955 DUPLEX > RECEPTACLE — MOUNTED 18" AFF TO CENTERL Ph. 407 422 4076INE I UNLESS NOTED OTHERWISE r Fax. 407 839 0832 (GFI) GROUNDED FAULT INTERRUPTING , (REF) REFRIGERATOR (WP) WEATHERPROOF - DOUBLE DUPLEX RECEPTACLE - MOUNTED 18" AFF TO CENTERLINE. 1' UNLESS NOTED OTHERWISE DUPLEX RECEPTACLE — MOUNTED 6": ABOVE COUNTER 'BACKSPLASH r ..fi C -® UNLESS 'NOTED OTHERWISE ` Ik _ DOUBLE DUPLEX RECEPTACLE — MOUNTED 6" ABOVE COUNTER BACKSPLASH NOTED —® UNLESS OTHERWISE DUPLEX RECEPTACLE. — MOUNTED FLUSH IN CEILING ® UNLESS NOTED OTHERWISE : D COMMUNACATION OUTLET — MOUNTED 18" AFF UNLESS OTHER :NOTED A ; CONTRACTOR SHALL PROVIDE AND INSTALL" 2 GANG JUNCTION BOX WITH 1 GANG PLASTER RING AND STUB 1". C. TO CEILING (1) CAVITY SPACE FOR PLENUM RATED COMMUNICATION CABLING TO CONDUIT STUBBED INTO 4a TENANT SPACE FOR TELEPHONE AND COMMUNMICATION SERVICES. VERIFY - EXACT LOCATION OF TELEPHONE /COMMUNICATION STUB IN TENANT SPACE.° •�-[] © CONTACTOR Z , TIMECLOCKLij a .• SPECIAL PURPOSE OUTLET m v) V) (� 0 .. MOTOR ENEINEERS ILA ENGINEERING CGMPANY 5105 Pine Top Place ❑rlanclo, FL 32819 Phone 407=876-5900 Fax 407-876-0885 �I t �E. �f SHEET N0. - p" PROJ.—NO.,, SCALE DATE. - DRAWN —BY a CHECKED —BY GALA- , , r _ F r ,r : - .,.- ., t--,.. « k r-.a`'.1 ,. rR : ,. .... ,. ,a- r.t ... :. _. .- .... �. a . :,: ., ., .,.. .�-��..•... SUSPENDED 2x4 FLUOURESCENT FIXTURE ® 10'-0" A.F.F. (TYP). 7 6-6 TINUE POURED CONCRETE SLAB i LOCATION O LLJ S. J I .,.v _ s -ter w � 1 REVISION 1 �. 4 gA PROJ._NO. SCALE DATE: DRAWN -BY CHECKED -BY 'J A 3 RFFi PARTIAL PLAN.. ELECTRIC FC.TFn cRi INC Pi AN r Cuhaci & Peterson Architects, � Inc. 200 E. Robinson St.'` Suite 400 Orlando, Florida 32801-1985 Ph. 407 422 4076 Fax. 407 839 0832 s cy— Q O U �. O 0. ULLJ .O CyO 'J LLB, 0 V) 4 � ����...IV) REVISION Al o 6 8 4 A PROD. —NO. SCALE DATE: DRAWN —BY CHECKED —BY GENERAL PROJECT NOTES The complete electrical installation shall comply with NFPA 70— 1993 National Electric Code. EQUIPMENT /SYSTEM IDENTIFICATION Install engraved plastic laminate sign on each major unit of electrical equipment. Except as otherwise indicated, provide single line of text, 1 /2 inch lettering on 1-1/2 inch 'high sign (2 inch high where 2 lines are required), white lettering in black field. Provide text matching terminology and numbering of the contract documents and shop drawings. ' Provide signs for each unit of the following categories of electrical work: Motor starters Disconnect switches Panelboards Transformers Inscriptions shall indicate the device served i.e. "panel LI', "HVAC UNIT # 1 , etc. Update panelboard directories to accurately indicate new equipment served and equipment being removed. ELECTRICAL DEMOLITION AND ALTERATIONS The existing building is to remain in operation during construction. Coordinate all work that will interfere with the present operation of the facility with the Owner. Provide all coring that is required for electrical work. Obtain prior approval' from the Architect/Engineer if any coring is required through structural members. All conduit and wiring required in existing construction shall be concealed except conduit may be run exposed in unfinished rooms such as equipment and mechanical rooms. Provide all cutting and patching required for electrical work. ELECTRICAL METALLIC TUBING (EMT) FS WW—C-563, ANSI C80.3 and UL 797. Minimum conduit size 1 /2 inch. ANSI C80.4, steel fittings. Threaded insulated throat, gland compression or set screw type. Rain and concrete tight. Diecast fittings are not acceptable. LIQUID —TIGHT FLEXIBLE CONDUIT PROVIDE UL—Listed liquid —tight flexible metal conduit. Minimum size 1 /2 inch. Provide cadmium plated malleable iron fittings with compression type steel ferrule and neoprene gasket sealing rings. Liquid —tight. PANEL SCHEDULE P P 8A VOLTAGE MLO MB AMPS F S AIC 208 120 3 MB 50 F 42,000 CKT DESCRIPTION WIRE TRIP CKT DESCRIPTION WIRE TRIP 1 LIGHTING 12 20 2 LIGHTING 12 20 3 LIGHTING NIGHT 12 20 4 VAV CONTROL 12 20 5 VAV CONTROL 12 20 6 RECEPTICLE 12 20 7 SPARES 8 SPARES g 10 11 t 12 13 14 15 16 17 18 19 20 i FLEXIBLE STEEL CONDUIT UL-1 formed from continuous length of spirally wound, interlocked hot -dip galvanized steel. Minimum size 1 /2 inch. Provide squeeze type, malleable iron cadmium plated conduit fittings for use. with flexible steel conduit of threadless hinge type: Threaded:- Grounding type: insulated throat. CONDUIT INSTALLATION Install conduit and tubing products in accordance with NEC, manufacturer's written instructions, and applicable standards. Connections to Motors and Equipment Subject to Vibratiorf: Flexible steel conduit not over 3 feet long where concealed in "cabinet, or where exposed in mechanical and utility areas and not subject to moisture., dirt, and fumes. Liquid —tight flexible conduit not over 3 feet long where exposed in finished + areas or where subject to moisture, dirt, fumes, oil, corrosive atmosphere, exposed or concealed, with connectors to assure a liquid —tight, permanently grounded connection. Locate so it is least subject to physical abuse. WIRE AND CABLE All conductor and conduit sizes are based on the use of copper conductors. All conductors shall be copper. Type THHN/THWN, single conductor, size as indicated on drawings. WIRE AND CABLE IDENTIFICATION Color. Code Conductor Insulation as follows: SYSTEM VOLTAGE SYSTEM VOLTAGE CONDUCTOR 208Y/120 480Y/277V Phase A Black Brown Phase B Red Orange Phase C Blue Yellow Neutral White Gray Ground Green Green w/ tracer If existing building conductor color coding is different than that indicated above, conductor color coding shall match existing. Install label tags on wire and cable in junction boxes, pull boxes, wireways, and wiring gutters of panels. Tags shall identify wire or cable number and/or equipment served as shown on drawings. JUNCTION AND PULL BOXES Fabricate from code gauge galvanized steel, with covers held in place by corrosion resistant machine screws. Size as required by code for number of conduits and conductors entering and leaving box. Provide with welded seams, where applicable, and equip with corrosion — resistant, nuts, bolts, screws, and washers. INSTALLATION Install electrical boxes in compliance with NEC requirements, in accordance with the manufacturer's written instructions and with recognized industry practices to ensure that the boxes serve the intended purposes. Install knockout closures to cap unused knockout holes where blanks have been removed. Locate boxes so as to assure accessibility of electrical wiring. Secure boxes rigidly to - the, substrate upon which they are being mounted. Do not support from conduit. GENERAL DUTY DISCONNECT SWITCHES Provide surface mounted, general duty type sheet steel enclosed safety. switches, that are fusible or non —fusible, with voltage rating for circuit, amperage, and number of poles as indicated on drawings. Switches shall be quick make, quick break type: constructed so that switch blades are visible in "OFF" position with door open. Equip with operating handle which is integral part of enclosure base and whose operating position is easily recognizable, and is capable of being padlocked in 'OFF" position. Switches shall have a cover interlock to prevent unauthorized opening of the switch door when the handle is' in. the "ON" position. Construct . current carrying parts of high conductivity copper, with silver —tungsten 'type.,,switch contracts. Provide positive pressure type reinforced fuse clips for fusible switches. Provide NEMA 1 or 3R enclosure, as required, with stamped knockouts. RMS short circuit rating shall be 200,000 amps with R fuses. INSTALLATION Install in accordance with manufacturer's written instructions applicable requirements of NEC and NEC's "Standard of. Installation and in accordance with recognized industry practices. Locate disconnect switches as shown or called out on drawings and as required by NEC. Ground electrical systems and equipment as required by NEC. Install grounding conductor in nonmetallic or flexible conduit to complete equipment ground continuity. GROUNDING Install a separate equipment grounding conductor sized pere NEC Table 250-95 in all raceways. PANEL SCHEDULE I P C� VOLTAGE MLO MB AMPS F S AIC 208/120/3 MLO 50 F 42,000 CKT DESCRIPTION WIRE TRIP CKT DESCRIPTION WIRE TRIP 1 LIGHTING 12 20 2 LIGHTING 12 20 3 LIGHTING NIGHT 12 20 4 RECEPTICLES - VAV BOX 12 20 5 RECEPTICLES 12 20 6 RECEPTICLES 12 20 7 RECEPTICELS 8 SPARES 9 SPARES 10 11 F 12 13 14 15 16 17 18 19 20 BRANCH CIRCUITS Do not use wire smaller than No. 12 AWG (unless otherwise noted) for branch circuit wiring, including motor circuits. Voltage drop for branch circuits and feeder circuit combined shall not exceed requirements of NEC Article 215. Size conduit, outlet boxes, and other raceway system components in accordance with NEC requirements as minimum. MOTOR AND EQUIPMENT WIRING Furnish and install motor circuits in accordance with drawings and code requirements, from source of supply to associated motor starter, and from starter to motor terminal box, including necessary and required intermediate connections. Conductor and conduit size for motor branch circuits, if show'n on drawings, are sized for motor requirement only, Contractor may at his option, include associated control conductors in some conduit providing the conduit size is adjusted to meet code requirements for percentage of fill. Motors shall have proper feeders as per NEC and nameplate ratings. Verify ratings of motors and installing proper branch circuits. EQUIPMENT CONNECTIONS Obtain manufacturer's wiring diagrams of electrical equipment furnished with equipment and do not proceed to wire equipment without this information. Verify all equipment feeder sized, overcurrent protection sizes, etc. recommended by equipment manufacturer before installing. Make equipment connections with flexible metallic conduit, Properly ground non —current carrying metal parts of equipment. Coordinate work with the other trades such that the operation of mechanical equipment will be as described in mechanical specifications. Check drawings and specifications of other divisions of work for equipment and work which must be included whether of not shown on electrical drawings, in order to provide a complete electrical installation. Unless otherwise indicated on drawings or in specifications, equipment shall be furnished, set in place, and connected and proper disconnecting means shall be provided. Motor connections shall be made by split —bolt type connectors using proper tools and fittings to assure good electrical continuity and low resistance joint. PANEL SCHEDULE PA8 VOLTAGE MLO MB AMPS F S AIC 208 120 3 MLO 50 F 42,000 DESCRIPTION I WIRE TRIP CKT DESCRIPTION WIRE TRIP -CKT1 1 LIGHTING 12 20 2 VAV CONTROL 12 20 3 NIGHT LIGHT 12 20 4 RECETICLES 12 20 5 SPARE 6 SPARE 7 F 8 g 10 11 12 ENGINEERS Cuhaci & Peterson Architects, � Inc-. 200 E. Robinson St. Suite 400 Orlando, Florida 3280i-')955 Ph. 407 422 4076 Fax. 407 839 0832 Q z � U LL- U 0 y-- U LLJ 0 o zLLJ �. z ' o `� V) � REVISION 0 d PROJ._NO. SCALE DATE: DRAWN —BY CHECKED —BY iown a-, inAn oil 00 I g� 12 X-7 ahplo Ty Z&yg I IWd Mwl 'Wool, I Wow A fee a 0 t�ottlow, IIIVA , g" -X- ?--On yowl "I aAli " ic 7 AOUT lot On mp Arm moms, -y" pow iIIII tug cot" On A"Anz I, WT-W for A, -vat- Rimy. Bill Irush IAi qqw!, IIWMI CA IIIpn§4 Nor MMS too,, downs Way jw".41A toll II A out wagg, _oTrlls =rat nymp WT, VIE IiWP . K ��i I�j ZVI 41 cc, og It t,4 pow �:A f. IIIAAA�—N ORA LAO -M, Ila vat IIIIII" VAL 4 -' If -AP At napoly; V 'WTI IIUi IImp— jg� Ivan, K In "ION nAd aIA Any IAIwt tin IA IIInil Vol low no Q� Tel at R i�f co 7 ; aQ jr IIIinICITY AojW Ali ap !, n �: IIMin. AI'Not, ICIA 14 mot," 7 I3 I 00 g -I lava ITq, -01 Iall Iwon owl A Runoff —Wg" sau too, jif -Q iAp WMIX, IIIiaits, Ww" "Two 41111 IIAll$, 4 w 14 -T- Now W�7 Iaits CIL -ha alogo, ilk IaI�1 -Xho to% inown shot in4 Ana 11y .-wool InVol. IIdoll so! I00, OVA". kAIow- 01A My I"O Apo,, goo IIIN IJ1 0, �p Win Wwo I�0? two- 411 AX M Tgnij has aMrs ""a' cot " so OF Q- coots MCI Ipit I -PRO 7-� AAAIN Pill gw. M I-n- spot MUK IQ II"Mal IIIIIIAYR AM, �w "Aug IIQ Vol awa Iowl I -Sr too coo; OQ Ilk lot son "A IIPAWN! 10011 SKinywin 4"N IISoo IITto! 1 Imm, -WNW to! lion , C❑❑RDINATI❑N NOTES GENERAL NOTES: 1, A/C CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE HIS WORK 1, THE CONTRACTOR SHALL PR❑VIDE ALL LABOR, MATERIALS, FOR SIZE, LOCATI❑N, CLEARANCE, ACCESS AND ELECTRICAL CHAR- EQUIPMENT, ACCESS PANELS, CONTROL SYSTEMS; DEVICES, PERMITS CHARACTERISTICS WITH ALL OTHER TRADES AND TO PROVIDE SHOP AND SERVICES NECESSARY FOR FURNISHING AND INSTALLING OF A DRAWINGS TO THE ENGINEER FOR REVIEW BEFORE INSTALLATI❑N OF COMPLETE SERVICEABLE MECHANICAL SYSTEM, DUCTWORK OR EQUIPMENT, SHOP DRAWING WILL INCLUDE BEAM OR STRUCTURE ELEVATI❑N & REQUIRED EQUIPMENT ACCESS AREAS. 2, ALL MECHANICAL SYSTEMS ARE TO BE INSTALLED ACCORDANCE WITH ALL APPLICABLE SECTIONS OF THE NFPA 2. WALL, ROOF, AND CEILING OPENINGS INDICATED ON CONTRACTOR STANDARDS, ANSI STANDARDS, THE LOCAL BUILDING CODE, PLANS 300ICFM DRAWINGS ARE NOMINAL DIMENSIONS ONLY AND ALL DUCT, PIPE ❑R AND SPECIFICATI❑NS, EQUIPMENT PENETRATI❑N SHALL BE SLEEVED AND FIRE RATED AS REQUIRED, ADJUST OPENINGS. 3, ALL MATERIALS SHALL BE NEW (UNLESS ❑THERWISE INDICATED) AND ANY DAMAGED EQUIPMENT SHALL BE REPLACED, 3, C❑❑RDINATE L❑CATION OF CEILING DIFFUSERS, GRILLES AND REG- ISTERS IN THE FIELD WITH LIGHTS, SPRINKLERS AND 4, CONTRACTOR WILL WARRANTY ALL MECHANICAL SYSTEMS, EQUIPMENT, ARCHITECTURAL ELEMENTS, PARTS AND LABOR FOR A PERIOD OF ONE (1) YEAR `AFTER C, ❑„ 4. C❑❑RDINATE L❑CATI❑N OF A/C UNITS, THERMOSTATS, FANS AND 5t PR❑VIDE MAINTENANCE AND OPERATION MANUAL ON ALL MECHANICAL 6' x Is' DUCTWORK WITH BUILDING STRUCTURE AND OTHER TRADES SO EQUIPMENT OR SYSTEMS: PR❑VIDE 5 SETS OF SUBMITTALS ❑N ALL THAT NO INTERFERENCE OCCUR, HVAC EQUIPMENT. SUBMITTALS SHALL HAVE A SUMMARY SHEET 5. IN GENERAL, DUCT OFFSETS HAVE NOT BEEN SHOWN. A/C CONTRACTOR SH❑WING ALL SCHEDULED INF❑RMATI❑Nt TO C❑❑RDINATE THESE AS REQUIRED, 6, NO COMBUSTIBLE MATERIALS ARE ALLOWED IN RETURN AIR PLENUMS PD OR ABOVE CEILINGS USED FOR RETURN AIR, 40c 6, MECHANICAL PLANS IN GENERAL, ATE DIAGRAMMATIC IN NATURE, AND ARE TO BE READ IN C❑NJUNCTION WITH ARCH, PLUMBING, ELECTR- 7, ALL CUTTING, PATCHING, STRUCTURAL STEEL, WEATHER PROOFING, ICAL AND STRUCTURAL PLANS, DUCT AND PIPING OFFSETS, BENDS PAINTING, AND WALL ❑PENINGS SHALL BE BY THE GENERAL AND TRANSITIONS WILL BE REQUIRED TO PR❑VIDE AND INSTALL A CONTRACTOR. COMPLETE FUNCTIONAL SYSTEM AND SHALL BE PROVIDED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER, 8, ALL LOUVERS, GRILLS, PIPING, ETC, SHALL BE PAINTED TO MATCH SURROUNDING COLOR AND Textures AS REQUIRED BY ARCHITECT, 36" x 24" RETURN AIR � ,' X 15' 8' X 15' 7t THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR T❑ VERIFY COLOR AND TEXTURE WITH ARCHITECT, PAINT ALL EXPOSED- WITH FIRE DAMPER � BIDDING, ORDERING, FABRICATI❑N OR INSTALLATION OF MATERIALS MECHANICAL EQUIPMENT WITH BENJAMIN M❑ORE EPDXY ENAMEL 182, OR EQUIPMENT: s EQUIPMENT SCHEDULE; a VAV-4 TRANE VAV BOX, MODEL VCCE-11, 900 CFM MAX, 400 CFM MIN, PR❑VIDE DDC CONTROLS AND WALL SENSOR, El VAV-2 & VAV-3 TRANE VAV BOX MODEL VCCE-32, 3200 CFM MAX. 1000 CFM MECHANICAL EQUIPMENT NOTES 10' x 16' MIN, PR❑VIDE DDC CONTROLS AND WALL SENSOR, 11 ALL MECHANICAL EQUIPMENT SHALL BE ARI & U, L. LISTED VAV-1 &-5 &-6 TRANE VAV BOX. MODEL VCCE-17, 1600 CFM MAX, 500 CFM MIN. WHERE APPLICABLE AND RATED FOR THE REQUIRED SERVICE, PR❑VIDE DDC CONTROLS AND WALL SENSOR, PRESSURES, TEMPERATURES, AND SHALL BE PROVIDED WITH ALL NECESSARY TRANSFORMERS, SEALS, VALVES, CONNECTI❑NS, ETC. TO FUNCTI❑N PROPERLY, 2, ALL INSULATION WILL HAVE FIRE/SMOKE RATING LESS THAN e' x Is' - x Is' 25/50, 3, PROVIDE A MIN, OF 3' CLEARANCE IN FRONT OF ALL 120-240 VOLT RATED AND 4' CLEARANCE IN FRONT OF ANY 480 VOLT RATED 2o' x 16, PANELS AND DISC❑NNECTS. PR❑VIDE ADEQUATE SIDE CLEARANCE PER NEC, IL 4, PR❑VIDE BACKDRAFT DAMPERS ON ALL EXHAUST FANS AND/OR IN LINE FANS, 5. HVAC CONTRACTOR SHALL TEST AND BALANCE ALL MECHANICAL EQUIPMENT AND AIR DEVICES, EXTRACTORS, DAMPERS, ETC, T❑ PR❑VIDE THE DESIGN QUANTITIES AS SHOWN ON THE PLANS OR A/C LEGEND SCHEDULES: PROVIDE T & B REPORT IN ACCORDANCE WITH THE AIR BALANCE COUNCIL STANDARDS. SIGNED AND SEALED BY A REGISTERED �/S WALL SWITCH O FLORIDA ENGINEER, 8• x Is" x Is' SD SMOKE DETECTOR O 6, ALL PIPING AND DUCTWORK SHALL BE SLEEVED THRU WALLS, BEAMS, 24' x 16' 121 SLABS, ETC, AS REQUIRED AND C❑ORDINATED WITH THE STRUCTURAL OHEAT DETECTOR (FIRE STAT) ENGINEER, PROVIDE NECESSARY TRANSITI❑NS AS REQUIRED FOR C DUCTWORK INSTALLATION, ® � OTHERMOSTAT - SUPPLY AIR (DIRECTION OF THROW) vav z -'\/--RETURN AIR -'�,'9- UNDER CUT DOOR (1" MIN UNLESS INDICATED) SUPPLY AIR DUCT OR GRILLE DUCTWORK AND ACCESSORIES NOTES: RETURN AIR DUCT OF GRILLE 1, ALL DUCTWORK SHALL BE AS FOLLOWS, log A) SUPPLY ' - GALV, SHEETMETAL W/ 2" 3/4 LB WRAP, PD 14' PD 14' EXHAUST AIR DUCT OR GRILLE B) RETURN - GALV, SHEETMETAL W/ 2" #/$ LB WRAP, 400 CFM 400 CFh C) GALV SHEETMETAL, --0 FIRE DAMPER WITH ACCESS DOOR. 2, ALL DUCTWORK' SHALL BE BUILT AND INSTALLED IN ACCORDANCE -----Vs SMOKE DAMPER WITH ACCESS DOOR WITH "SMACNA" STANDARDS AND LOCAL BUILDING CODES. DUCTWORK SHALL HAVE A PRESSURE CLASS OF 2" WG, UNLESS ❑THERWISE 8"X16" 5"X16" —�i SPLIT DAMPER STATED, - - - EXISTING DUCTWORK 3. PR❑VIDE TYPE "B" FIRE DAMPERS WITH ACCESS DOORS IN ALL DUCTS OR ❑PENINGS PENETRATING FIRE RATED- WALLS, TENANT . )f- � -X EXISTING DUCTWORK TO BE REMOVED SEPARATION, PARTIT.I❑NS, (SEE ARCHITECTS PLANS FOR RATINGS), o DUCT TRANSITI❑N 4, USE RADIUS RECTANGULAR FITTINGS OR TURNING VANES IN ALL SUPPLY DUCT ELB❑WS, C❑NICAL BRANCH TAKE -OFFS, SPLITTER❑PPOSED BLADE DAMPER (❑BD) DAMPERS WHERE INDICATED ❑N DRAWINGS AND VOLUME CONTROL EXTRACTORS IN ALL BRANCH DUCTS ❑R DIFFUSER CONNECTI❑NS, PD GRILLE MARKER; INDICATES 4100 8' � TYPE "PD" GRILLE WITH 8" ROUND 5, ALL DUCT SIZES ARE CLEAR INSIDE DIMENSIONS. Iso NECK, BALLANCE FOR 150 CFM; 6, PLANS ARE DIAGRAMMATIC, IN GENERAL DICT ❑FFSETS HAVE Io' x I6' NOT BEEN SHOWN. A/C CONTRACTOR SHALL COORDINATE THESE ASREQUIRED WITH BUILDING STRUCTURE AND OTHER TRADES,CFM TOILET EXHAUST 7, SEAL ALL DUCTS, JOINTS AND SEAMS IN AN APPROVED MANNER AND INSURE AGAINST LEAKAGE, 8, TERMINAL AIR DISTRIBUTI❑N DEVICES SHALL BE 'TITUS AS FOLLOWS: A) CD CEILING DIFFUSER MODEL TDC-AA WITH SQUARE OR ROUND NECK, /� / C PLAN LA F 11 B) PERFORATED DIFFUSER PAS AND PAR, f-1 C) RAG RETURN AIR GRILLE MODEL 350FL, SCALE 1/8' _ V -0' PROD. —NO. SCALE lib" DATE: DRAWN —BY CHECKED —BY k: f SHEET N0. _;w k CAI AN -A 1 ; i 45 +;: f 7 73