HomeMy WebLinkAbout204 Towne Center Cir 95-2749 New build out MallGENERAL NOTE$: I. ALL WORK TO BE PERFORMED IN COMPLIANCE WITH APPLICABLE BUILDING CODES AND SPECIFICATIONS BY SEMINOLE TOWNE CENTER MALL 2. MARK DEMISING PARTITIONS AS REQUIRED ABOVE CEILING TO INDICATE I HOUR FIRE RATED PARTITION 3. CONTRACTOR TO VERIFY EXISTING CONDITIONS AND DIMENSIONS NOTE S: O FIXTURE / SHELVING BY TENANT 2O ENCLOSE COLUMN AT MIN. DIMENSIONS W/ GYP. BOARD TO ABV. W-m" �3 PROVIDE CUT IN FLOOR AND CONDUIT WITH 4-PLEX OUTLET AT COUNTER AND FLOOR LOCATION AT FRONT WINDOW. ALSO (1) BLANK CONDUIT FOR PHONE AND DATA LINE TO STORAGE RM. O METAL CLAD WOOD MOULDING, FLAT FACE 1/2" x 4 I/8" FINISH SCHEDULE AREA DESCRIPTION COLOR COMMENTS CEILING 2'x4' (SCORED 2'x2') OR 2'x2' LAY -IN SUSPENDED CEILING WHITE SIMILAR TO ARMSTRONG "MINIBOARD" FLOOR a STORAGE SEALER ON CONCRETE CLEAR FLOOR e SALES CARPET (MOHAW'K ERRS) 235 TERRACOTTA VINYL BASE BY CONTRACTORS' SUBMITTAL WALLS m STORAGE NO FINISH WALLS tv SALES BENJAMIN MOORE (FLAT) 1213 UNLESS NOTED OTHERWISE ON PLANS DOOR tv STORAGE BENJAMIN MOORE (SATIN) MATCH WALLS ENTRY COLUMNS TO BE SELECTED MATCH EXTERIOR FACADE FACADE - MALL SIDE TO BE SELECTED 4" VINYL BASE INFERIOR ELEVATION SCALE: 1/4 = 1'-011 V UTILITY�•a,i aEcTIQN. FEIL fVo P/ 11BJ - I PAINT COL. III SAME COLOR ;n , 0 AS FACE = CUhaCI & P �t 'r - - - - - - - - - - - - - - - - - - - 1 e,. SECURITY GRILL Architects lac. TRACK II FINISH LIMIT EXTEND D f !' (ONLY THE FACE OF THIS ,,� --.1� III MALL TILE � SOoeF400 binsonl;�t 5 CURITY GRILL iiLl (N.f.CJ ---f.---- Orlando, Florida '.32$01 1955 - WALL SHALL f3E FINISHED) Ph. 407 422 r4:Q7CI PAINT, COLOR TO BE--Fi Fax. 407 839 332 .� SELECTED ' C - I I I I I I I I i 5 0 11 3 3/4 I 2 0 kLu =1 8 1/2" 2 1... 1..1� Q �_` i 11 0 1 I 1 F. - I \ I III = V ® , i U 1 SALES AREA O r- —� \ LINE F SOFFIT ABOVE �\ ( m J ,� - I \ ti� �/ • III � - ® O �;� EXIST. MALL OFFIT Iss— V > i \ \ I I NEW 50FF T L NE W Q W t-11 18MRACkE AREA \ I I ® O i NO FINISH SHALL BE \ - - - - - - - I I Z Z } I APPLIED TO UJALLS INSIDt"/ O \\ I GLASS LINE ' THIS AREA Z�----------� III Z CLEAR SEALER 3 ! C ET LIMIT , I I W Rfi 1 I ON CONCRETE _ _ _� I I U) I 3'0x&'8 '---------- ELECT. I------------- I-- -1 I PANEL I 24" SHELVES I 1 I 1 0 :I A 15'-3 1/4" 2-i'-I" 42' -10 1/4" Ir FLOOR FLAN SCALE: 1/4" = 1'-011 { z LO ' 1� SIGN (N.I.C.)_ qH ---PAINTED GYP. BD. j I----------� GOLD TRIM �/ CLIPS AS REa. PAINT E _ I.. T�..;.....:... �••.� N[ FRONT ELEVATION � �CL.1,11'CI I 1 GRILL r�ll�i � 111� SCALE: 1/4" = P-011 ® O0 U CD GYP.• BD. Victor P. `Rossi f Planning • Design • Creative So ' 407.682 •7540 • ;`s1 yv� LIGHT GAUGE METAL FRAME AS REQ'D. — NO CEILING 3 5/S" MTL. STUDS ,@24" O.C. NO GYP. BD. AT STORAGE LIGHT GAUGE METAL FRAME AS REQ'D. — +II'-0" CLG. LINE RECESSED DOWN LIGHT _ +I'-0" BOTT. OF SOFFIT "—GYP. BD. GYP. BD. DISPLA�'� PEDESTAL SECTION METAL DECK PROVIDE AND INSTALL ONE HOUR FIRE DAMPER FOR RETURN AIR — TO MALL HVAC UNIT. NON -RATED CEILING 5/8 FIRE CODE GYP. BD. r U.L. DESIGN NO.U405 TENANT SPACE 3 5/8" CONCRETE ON MTL. DECK PA2 NOT TO SCALE LIGHT GAUGE METAL FRAME ABOVE STOREFRONT GLASS 1 BRACE AS REQ'D.-F NOTE CONTRACTOR TO VERIFY SPACE REQ'D. FOR GRILLE ASSEMBLY ROLL -UP SECURITY GRILLE ' BEYOND STORE CE I ING — SOFFIT BEYOND GYP. BD. FIRESTOP (EXIST'G. - N.I.C.) EXISTING 3 5/8" MTL. STUDS e24" O.C. BY OTHERS NOTE: STUDS AND FIRESTOP — EXISTING (N.I.C.) APPLY 5/8" F.C. GYP. BD. TO TENANT SIDE ONLY W1 ADD'L. STUDS PER 4/2 TITION DETAIL NOT TO SCALE -U.L. NO. U465 TENANT 5gACE —EXISTING MALL SOFFIT LIGHT GAUGE EXISTING MALL SOFFIT METAL FRAME —DOUBLE LAYER 5/8" DOUBLE LAYER 5/8" GYP. BOARD GYP. BOARD Tt3'—ID" (VERIFY)__ NOTE F (VERIFY) — — CONTRACTOR TO — — VERIFY SPACE REQ'D. FOR I ! GRILLE ASSEMBLY ROLL —UP I SECURITY GRILLE I — 4" "GOLD BRITE" MTL. 4" "GOLD BRITE" MTL. COVERED TRIM ! COVERED TRIM I — PILASTER IN SIGN AREA STORE CEILING PILASTER IN SIGN AREA UJ/ REVEAL 5" FROM € W1 REVEAL 5" FROM TOP AND BOTTOM SOFFIT F TOP AND BOTTOM REVEAL REVEAL GYP. BD. j FACE OF NEUTRAL PIER f— FACE OF NEUTRAL PIER BEYOND j BEYOND FRAMELESS GLASS STOREFRONT W1 POLISHED _ RECESSED SECURITY GRILL EDGE. NO SILICONE. TRACK ON 3"x3" STEEL CONNECT W1 BRITE �, I TUBE FRAME SILVER CLIPS — '•I t MALL SPACE TENANT 5FIACE MALL SPACE 'i � E REVEAL REVEAL BRITE "GOLD" BASE F ! I F-- MALL TILE MALL TILE MALL TILE EXTENDED MALL TILE EXTENDED TO STOREFRONT (N.I.C.) TO STOREFRONT (N.I.C.) SECTION lo-) 5T0�EP5�,)0NT NOT TO SCALE GYP B I DEMISING WALL STUDS ' N.I.C. TENANT SPADE Y OTHERS BRITE LASS GOLD" ACK GR�1I \ll III II II 0311 1, 8 0311 _ LEASE LINE �n LIMITS OF G.F.R.C. TENANT STOREFRONT NEUTRAL PIER SCREW ATTACH TO FIRE TREATED WD. BLOCKING AND OR MTL. STUDS DETAIL AT NUTRAL FIR NOT TO SCALE SECTION � SCREEN PROVIDE NEOPRENE DECK CLOSURE WHEN NON -RATED PARTITION IS PERPENDICULAR TO DECK RIB NOT TO SCALE PROVIDE FIRE STOP CLOSURE WHEN FIRE RATED PARTITION IS PERPENDICULAR Tp DECK RIB RUNNER W1 2" LOi G I — LEGS ATTACHED TO "J" IM (TYP) METAL DECK W1 3/8" FRAMING SCREWS 5/8" GYP. BD. 4 I/ Vll BOTH SIDES± DO NOT STANDARD RUNNER ATTACH TO LONG FREE TO SLIDE IN LEG RUNNER LARGER TRACK SEE PARTITION BRIDGING PER TYPE OR STUD STUD MANUF, SIZ E AND SPACING RECOMMENDATIONS NOTE: I. USE SLIP CONNECTION AS SHOWN AT ALL LOCATIONS WHERE PARTITIONS ARE THRU TO STRUCTURE. PA TITIO� D�TAI� NOTE: NOT TO SCALE STUDS AND FIRESTOP — EXISTING (N.I.C.) APPLY 5/5" F.C. GYP. BD. TO TENANT SIDE ONLY U1/ ADD'L. STUDS PER 4/2 " i f a F: Cuhaci & Peterson 7 ''r Architects, Inc. 200 E. Robinson St. Suite 400 ts, Orlando, Florida 328017:1-955 Ph. 407. 422 4076 Fax. 407 839 0832 JOB, NO. 95-1271 SCALE NOTED DATE 8/11/95 DRAWN SAL CHECKED PADS i LIGHTINGFIXTURE SCHEDULE MARK LAMP DATA DESCRIPTION FIXTURE MODEL NUMBER MOUNT VOLT NOTES # 1 QTY. TYPE MANUFACTURER CATALOG NUMBER A 4 70W R20 TRACK LIGHTING FIXTURE PRESCOLITE T112-WH TRACK 120 B 8 TRACK LIGHT SIGNLE CIRDUIT LIGHTING TRACK PRESCOLITE 4-TS8-WH & TS2-85 SURF 120 C 2 TRACK LIGHT LIGHTING TRACK PRESCOLITE 2-70WR2D SURF 120 5 D 1 2'X2' 2-U FLORESCENT FIXTURE 2-40W PARABOOIC LENSE 120 E 2 F22T8 2'X4' RECESS PARABOLIC LITHONIA PARABOLIC LENSE RECESSED 120 F 1 HALOGEN INCANDESCENT DOWNLIGHT LITHONIA LICM-MCIA REC PLAST 120 X W/ UNIT SINGLE FACE EMERGENCY EXIT LITHONIA QMSW3REL UNIVERISAL 120 2,3 TYPE "X" EQUAL EMERGILITE PL-W-SRX-X32-R BU W/ UNIT EMERGENCY BATTERY UNIT LITHONIA 6ELM2 UNIVERSAL 120 2,3,4 TYPE "BU" EQUAL EMERGILITE JSM18-2 LIGHTING FIXTURE NOTES: 1. GENERAL SCHEDULE NOTES ' (APPLIES TO ALL FIXTURES). A) CONTRACTOR SHALL COORDINATE FIXTURE MOUNTING WITH ARCHITECTURAL REFLEDC CEILING PLAN(S) AND SHALL PROVIDE FIXTURE MOUNTING AS REQUIRED TO MATCH CEILING TYPE. B) ALL FIXTURES BALLASTS SHALL BE HIGH POWER FACTOR TYPE. C ALL FLUORESCENT BALLASTS SHALL BE ENERGY SAVING TYPE. 2. FIXTURES TO BE PROVIDED WITH INTEGRAL EMERGENCY BACK-UP. 3. FICTURES SHALL BE CONNECTED TO CONSTANT NORMAL ROOM LIGHTING BRANCH CIRCUIT OF AREA SERVED (i,e, LOAD SIDE OF BREAKER, LINE SIDE OF ANY SWITCHING/CONTROLLING DEVICES. 4. FIXTURE SHALL BE WALL MOUNTED +7' -6" AFF TO TOP. 5. PROVIDE ALL NECESSARY ACCESSORIES AND HARDWARE REQUIRED FOR A COMPLETE INSTALLATION INCLUDING, BUT NOT LIMITED TO, DEAD ENDS, POWER FEEDS, ETC. NOTE: FIXTURE MANUF. EQUALS WILL BE ACCEPTABLE GENERAL ELECTRICAL NOTES: 1. CONDUCTOR CABLE TYPES AC AND NMC ARE NOT ACCEPTABLE. 2. ALL WIRING SHALL BE COPPER, ALUMINUM WIRING SHALL NOT BE PERMITTED. 3. CONTRACTOR SHALL GROUND SEPARATELY DERIVED SERVICES) IN ACCORDANCE WITH NEC ARTICLE 250. BOND GROUND TO BUILDING STEEL WHERE AVAILABLE. 4. ALL PANELBOARD CIRCUIT BREAKERS SHALL BE BOLT -ON TYPE. 5. STORE SIGN SHALL BE WIRED VIA CONTRACTOR, SQUARE D #LG-60. (SEE PLANS FOR CIRCUITS). AND CONTROLLED BY A SEVEN-DAY TWENTY-FOUR HOUR TIME CLOCK. TORK #T7200L. KEYED ELECTRICAL NOTES: 1 RECEPTACLE SHALL BE MOUNTED IN SOFFIT AREA OF LUMINOUS CEILING.. CONTRACTOR SHALL VERIFY EXACT LOCATION OF RECEP- TACLE WITH -ARCHITECT AND TENANT IN FIELD PRIOR TO ROUGH IN. 2 CONTRACTOR SHALL PROVIDE AND INSTALL 2' X 2' "EGG -CRATE" LOUVER IN CEILING GRID AT + 10'-2" AFF FOR LUMINOUS CEILING. CONTRACTOR SHALL COORDINATE ALL WORK WITH ARCHITECT IN FIELD CONTRACTOR SHALL VERIFY EXACT COLOR AND FINISH OF "EGG -CRATE CEILING WITH ARCHITECT AND TENANT PRIOR TO ORDERING MATERIAL SYMBOLS FLOURESCENT LIGHTING FIXTURE — CEILING MOUNTED Q FLOURESCENT INCANDLESCENT OR HID DOWNLIGHT FIXTURE — CLG. MOUNTED TRACK LIGHTING FIXTURE — CLG. MOUNTED X EMERGENCY BATTERY EXIT LIGHTING FIXTURE UNIT %mm? EMERGENCY BATTERY UNIT LIGHTING FIXTURE — WALL MOUNTED SINGLE POLE TOGGLE SWITCH — MOUNTED 42" AFF TO CENTERLINE UNLESS OTHERWISE NOTED. (3) =, 3WAY DUPLEX RECEPTACLE — MOUNTED 18" AFF TO CENTERLINE UNLESS NOTED OTHERWISE (GFI) GROUNDED FAULT INTERRUPTING (REF) REFRIGERATOR , (WP) WEATHERPROOF DOUBLE DUPLEX RECEPTACLE — MOUNTED 18" AFF TO CENTERLINE UNLESS NOTED OTHERWISE DUPLEX RECEPTACLE — MOUNTED 6" ABOVE COUNTER BACKSPLASH UNLESS NOTED OTHERWISE DOUBLE DUPLEX RECEPTACLE — MOUNTED 6" ABOVE COUNTER BACKSPLASH UNLESS NOTED OTHERWISE ®DUPLEX RECEPTACLE — MOUNTED FLUSH IN CEILING UNLESS NOTED OTHERWISE D COMMUNACATION OUTLET — MOUNTED 18" AFF UNLESS OTHER NOTED CONTRACTOR SHALL PROVIDE AND INSTALL 2 GANG JUNCTION BOX WITH 1 GANG PLASTER RING AND STUB (1) 1" C. TO CEILING CAVITY SPACE FOR PLENUM RATED COMMUNICATION CABLING TO CONDUIT STUBBED INTO TENANT SPACE FOR TELEPHONE AND COMMUNMICATION SERVICES. VERIFY EXACT LOCATION OF TELEPHONE /COMMUNICATION STUB IN TENANT SPACE. © CONTACTOR IT] TIMECLOCK ® SPECIAL PURPOSE OUTLET MOTOR DISCONNECT SWITCH O JUNCTION BOX = TERMINAL CABINET 7ELECTRICAL PANEL A (INDICATES DESIGNATION) O SEE NOTE SYMBOL SOLID LINE INDICATES EQUIPMENT ON COMMON CIRCUIT AND/OR CONTROLLED BY COMMON SWITCH. EACH CIRCUIT SHALL CONSIST OF A PHASE CONDUCTOR, NEUTRAL AND GROUND CONDUCTOR. ELECTRICAL CONTRACTOR SHALL PROVIDE NECESSARY SWITCH LEGS IN CONDUIT TO ACHIEVE SWITCHING INDICATED ON PLANS. ELECTRICAL CONTRACTOR MAY COMBINE CIRCUITS INTO A COMMON HOMERUN CONSISTING OF A COMMON NEUTRAL AND GROUND CONDUCTOR AND THREE (3) PHASE CONDUCTORS (A.B. AND C PHASE) /� DOTTED LINE INDICATES EQUIPMENT ON A COMMON CIRCUIT / \BUT NOT CONTROLLED ON SAME SWITCH DEVICE NOT ALL SYMBOLS MAY BE USED ENGINEERS ILA ENGINEERING COMPANY 5105 Pine Top Place Orlando, FL 32819 Phone 407-876-5900 Fax 407-876-0885 �c r r y •k. r Cuhaci & Pefers6li,,� l Architects, Inc. , 200 E. Robinson St. Suite 400 f Orlando, Florida 32801-1955 € Ph. 407 422 4076 t r Fax. 407 839 0832 z O azv z Q Q I- U Li 0 0 O O r F W Q W m V) C V) 0 Y■ 0 Z U W D Ln LLI I- W U F 0 = Q a: 0 _0 __j U) r� r: r� ro PROJ._NO. SCALE 1 4" = 1 DATE: DRAWN —BY CHECKED —BY SHEET N0. K5E If. f m ELECTRICAL PLAN PK-7 /PK-8 SCALE1 1/4' = 1'-0' PK-9 A B B B C II II ►I _ l III CIDD D D D INSIDE BOX S D I II I i � F I II JUNCTION IGN FOR ❑RE II I II A PK-17 '� ► PK-18 C ILI G HEIGHT = 1'-0' I F � � 1� B PK-1 I I I I II "11 PK-16 E � E i PK-15 Pk-`7 NO FINISHED CEILING AT STORAGE AREA II II I I II II II II II II II II II I I II I I PK-14 A D DEBII A D D A PK-13 I REELECTED CEILING PLAN SCALE: 1/4' = 1'-0' PK-10 PK-11 7 -4 ELECTRICAL LEGEND DUPLEX RECEPTACLE 4-PLEX OUTLET IN COUNTER I � � RECESSED DOWN LIGHT r� r� TRACK LIGHTING LJ LJ PH PHONE OUTLET O JUNCTION BOX (FOR SIGN) ELECTRICAL NOTFSi A - 4' 'LITE TRAC' BY PRESCDLITE (W/ 2 FIXTURES - TV 508) B - 8' 'LITE TRAC' BY PRESCDLITE (W/ 3 FIXTURES - TV 508) C - 2' 'LITE TRAC' BY PRESCDLITE (W/ 2 FIXTURES - TV 508) D - 2'x2' RECESSED FLUOR. W/ WARM WHITE LAMP E - 2-TUBE 4' FLUOR. FIXTURE, REFLECTOR 'HOODS' WIRE LAMP GUARDS. MOUNT AT 12' A.F.F. F - RECESSED DOWN LIGHTS ENGINEERS ILA ENGINEERING COMPANY 5105 Pine Top Place Orlando, FL 32819. Phone 407-876-5900 Fax 407-876-0885 L ,_I W i 0 I z w L1 Q L_L_J z Q 0 u 06, U r-1 ' f--i Ld LL r F- FZ I— Ld 0 U u z L-Li Q r a J CL o L1 I r REVISION r IA 4, PROJ._N0. SCALE DATE: DRAWN -BY CHECKED -BY- i SHEET N0. _ y KSE GENERAL' PROJECT NOTES i ... :, :Th. e com le to electrical installationshall comply with NFPA 70 —P E 1993 National Electric Code. . EQUIPMENT /SYSTEM IDENTIFICATION m i .Install engraved plastic laminate sign on each major unit of electrical equipment. Except as otherwise indicated, provide Single line of text, 1 /2 inch lettering on '1-1 /2 inch high sign -(21. inch high where 2..lines are required), white lettering in black field.Provide text matching terminology and numbering of F the contract documents and shop drawings. Provide -signs for each unit of the following categories of 4 electrical work: 4F, l Motor starters Disconnect switches i Ponelboards Transformers I _ Inscriptions shall indicate the device served i.e. "panel LI', " HVAC UNIT # 1, etc. l Update ponelboard directories to accurately indicate new r equipment served and equipment being removed. ELECTRICAL DEMOLITION AND ALTERATIONS The existing building is to remain in operation during construction. Coordinate all work that will interfere with the i present operation of the facility with the Owner. t i Provide all coring that is required for electrical work. Obtain I prior approval from the Architect/Engineer if any coring is E required through structural members. r All conduit and wiring required in existing construction shall be concealed except conduit may be run exposed in unfinished rooms such as equipment and mechanical rooms. Provide all cutting and patching required for electrical work. ELECTRICAL METALLIC TUBING (EMT) I _ FS WW—C-563, ANSI C80.3 and UL 797. Minimum conduit size 1 /2 inch. ANSI C80.4, steel fittings. Threaded insulated throat, gland compression or set screw type. Rain and concrete tight. R Diecast fittings are not acceptable. LIQUID —TIGHT FLEXIBLE CONDUIT PROVIDE UL—Listed liquid —tight flexible metal conduit. Minimum i size 1/2 inch. Provide cadmium plated malleable iron fittings with compression type steel ferrule and neoprene gasket sealing v _ rings. Liquid —tight. s' i Y r , S) C . E f f• t_ I t- 11 k FLEXIBLE STEEL CONDUIT UL-1 formed from continuous length of s irolly wound, interlocked hot —dip galvanized steel. Minimum size 1 /2 inch. Provide squeeze type, malleable iron cadmium plated conduit ~ fittings for use with flexible steel conduit of threadless hinge type: Threaded: Grounding type: insulated throat. CONDUIT INSTALLATION Install conduit and tubing products in accordance with NEC, manufacturer's written instructions, and applicable standards. Connections to Motors and Equipment Subject to Vibration: Flexible steel conduit not over 3 feet long where concealed in cabinet, or where exposed in mechanical and utility areas and not subject to moisture, dirt, and fumes. Liquid —tight flexible conduit not over 3 feet long where exposed in finished areas or where subject to moisture, dirt, fumes, oil, corrosive atmosphere, exposed or concealed, with connectors to assure a liquid tight, permanently grounded connection. Locate so it is least subject to physical abuse. WIRE AND CABLE All conductor and conduit sizes are based on the use of copper conductors. All conductors shall be copper. Type THHN/THWN, single conductor, size as indicated on drawings. WIRE AND CABLE IDENTIFICATION Color Code Conductor Insulation as follows: CONDUCTOR Phase A Phase B Phase C Neutral Ground SYSTEM VOLTAGE 208Y/120 Black Red Blue White Green SYSTEM VOLTAGE 480Y/277V Brown Orange Yellow Gray Green w/ tracer If existing building conductor color coding is different than that indicated above, conductor color coding shall match existing. Install label tags on wire and cable in junction boxes, pull boxes, wireways, and wiring gutters of panels. Tags shall identify wire or cable number and/or equipment served as shown on drawings. JUNCTION AND PULL BOXES Fabricate from code gauge galvanized steel, with covers held in place by corrosion resistant machine screws. Size as required by code for number of conduits and conductors entering and leaving box. Provide with welded seams, where applicable, .and equip with corrosion —resistant, nuts, bolts, screws, and washers. PANEL PK PANEL SCHEDULE VOLTAGE MLO MB AMPS F S AIC 208 120 3 0 MLO 100 F 42,000 CKT DESCRIPTION WIRE TRIP CKT DESCRIPTION WIRE TRIP 1 RECEPTICLES 12 20 2 RECEPTICLES- 12 20 3 RECEPTICLES 12 20 4 RECEPTICLES 12 20 5 SIGNAGE 12 20 6 VAV CONTROL 12 20 7 TRACK LIGHT 12 20 8 TRACK LIGHT 12 20 9 TRACK LIGHT 12 20 10 TRACK LIGHT 12 20 11 LIGHTING 12 20 12 LIGHTING 12 20 13 TRACK LIGHTING 12 20 14 TRACK LIGHT 12 20 15 LIGHTING 12 20 16 TRACK LIGHT 12 20 17 LIGHTING 12 20 18 NIGHT LIGHT 12 20 19 SPARE 20 SPARE 21 22. L;3:l 24 INSTALLATION Install electrical boxes in compliance with NEC requirements, in accordance with .the manufacturer's written instructions and with recognized industry practices to ensure that the boxes serve the intended purposes. Install knockout closures to cap unused knockout holes where blanks have been removed. Locate boxes so as to assure accessibility of electrical wiring. Secure boxes rigidly to the substrate upon which they are being mounted. Do not support from conduit. GENERAL DUTY DISCONNECT SWITCHES Provide surface mounted, general duty type sheet steel enclosed safety switches, that are fusible or non —fusible, with voltage rating for circuit, amperage, and number of poles as indicated on drawings. Switches shall be quick make, quick break type: constructed so that switch blades are visible in "OFF" position with door open. Equip with operating handle which is integral part of enclosure base and whose operating position is easily recognizable, and is capable of being padlocked in "OFF" position. Switches shall have a cover interlock to prevent unauthorized opening of the switch door when the handle is in the "ON" position. Construct current carrying parts of high conductivity copper, with silver —tungsten type switch contracts. Provide positive pressure type reinforced fuse clips for fusible switches. Provide NEMA 1 or 3R enclosure, as required, with stamped knockouts. RMS short circuit rating shall be 200,000 amps with R fuses. INSTALLATION Install in accordance with manufacturer's written instructions applicable requirements of NEC and NEC's "Standard of Installation" and in accordance with recognized industry practices. Locate disconnect switches as shown or called out on drawings and as required by NEC. Ground electrical systems and equipment as required by NEC. Install grounding conductor in nonmetallic or flexible conduit to complete equipment ground continuity. GROUNDING Install a separate equipment grounding conductor sized Pere NEC Table 250-95 in all raceways. ji" BRANCH CIRCUITS Do not use wire smaller than No. 12 AWG unless otherwise noted u t irin including r h motor circuits. forbranch circuit wiring, Voltage drop for branch circuits and feeder circuit combined shall not exceed requirements of NEC Article 215. > s1 Size conduit, outlet boxes, and other raceway system components in accordance with NEC requirements as minimum. I MOTOR AND EQUIPMENT WIRING 1 Furnish and install motor circuits in accordance with drawings and code requirements, from source of supply to associated motor starter, and from starter to motor terminal box, including I . necessary and required intermediate connections. Cuhaci ` & Peterson`1 , Conductor and conduit size for motor branch circuits, if shown on i i drawings, are sized for motor requirement only, Contractor may at Y y Architects �Inc. 4. . his option, include associated control conductors in some conduit providing the conduit size is adjusted to meet code requirements 200: E. Robinson St. 4" for percentage of fill. E Suite `400 I Orlando, Florida 32801-1955" Ph. 407 422 4076'. Motors shall have proper feeders as per NEC and nameplate I Fax. 407 839 0832, "."I. ,..: r ratings. Verify ratings of motors and Installing proper branch circuits. EQUIPMENT CONNECTIONS r I Obtain manufacturer's wiring diagrams of electrical equipment furnished with equipment and do not proceed to wire equipment without this information. Verify all equipment feeder sized, overcurrent protection sizes, etc. recommended by equipment manufacturer before installing. Make equipment connections with flexible metallic conduit, Properly ground non —current carrying metal parts of equipment. Coordinate work with the other trades such that the operation of mechanical equipment will be as described in mechanical specifications. i Check drawings and specifications of other divisions of work for equipment and work which must be included whether of not shown on electrical drawings, in order to provide a complete electrical installation. i Unless otherwise indicated on drawings or in specifications, equipment shall be furnished, set in place, and connected and proper disconnecting means shall be provided. Motor connections shall be made by split —bolt type connectors using proper tools and fittings to assure good electrical continuity and low resistance joint. EXISTING TENANT DISTRIBUTION BOARD TDB —A IN ELECTRICAL ROOM 30A 3P 25A DE INTEGRATED RATING = 50,000 RMS SYM. 1200 AMP BUS 480Y/277V, 30, 4W. --3# 10, 1 #40 GND 3/4" C. 30 A 3P POWER RISER NOTE DISC. SW. ALL NEW OVERCURRENT CAMPATIBLE WITH RE. 3# 10, 1 #40 GND 3/4" C. 480V. ,3� 15KAV 208Y/120V 3g, 4W • 3# 10, 1 #40 GND 3/4" C. - 60/3P MAIN BRKR NOTES: CONTRACTOR SHALL BE RESPONSIBLE TO MALL REPRESENTATIVE AND COORDINATE ALL NEW WORK WITH MALL UTILITIES AND THE OWNERS' REQUIREMENTS AS NECESSARY FOR A COMPLETE AND OPERABLE SYSTEM. POWER RISER DIAGRAM (TYPICAL FOR F-11, F-16, P8A, & A8 r PROJ.-NO.. SCALE DATE: DRAWN —BY. CHECKED -BY SHEET NO, , K5 E 3 GENERAL NOTES. 1. - THE CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, ACCESS PANELS, CONTROL SYSTEMS, DEVICES, PERMITS AND SERVICES NECESSARY FOR FURNISHING AND INSTALLING OF A COMPLETE SERVICEABLE MECHANICAL SYSTEM, 2, ALL MECHANICAL SYSTEMS ARE TO BE INSTALLED ACCORDANCE WITH ALL APPLICABLE SECTIONS OF THE NFPA STANDARDS, ANSI STANDARDS, THE LOCAL BUILDING CODE, PLANS AND SPECIFICATIONS. 3, ALL MATERIALS SHALL BE NEW (UNLESS OTHERWISE INDICATED) AND ANY DAMAGED EQUIPMENT SHALL BE REPLACED, 4, CONTRACTOR WILL WARRANTY ALL MECHANICAL SYSTEMS, EQUIPMENT, PARTS AND LABOR FOR A PERIOD OF ONE (1) YEAR AFTER C. ❑„ 5, PROVIDE MAINTENANCE AND OPERATION MANUAL ON ALL MECHANICAL EQUIPMENT OR SYSTEMS, PROVIDE 5 SETS OF SUBMITTALS ON ALL HVAC EQUIPMENT, SUBMITTALS SHALL HAVE A SUMMARY SHEET SHOWING ALL SCHEDULED INFORMATION, 6, NO COMBUSTIBLE MATERIALS ARE ALLOWED IN RETURN AIR PLENUMS OR ABOVE CEILINGS USED FOR RETURN AIR, 7. ALL CUTTING, PATCHING, STRUCTURAL STEEL, WEATHER PROOFING, PAINTING, AND WALL OPENINGS SHALL BE BY THE GENERAL CONTRACTOR, 8. ALL LOUVERS, GRILLS, PIPING, ETC. SHALL BE PAINTED TO MATCH SURROUNDING COLOR AND Textures AS REQUIRED BY ARCHITECT, VERIFY COLOR AND TEXTURE WITH ARCHITECT, PAINT ALL EXPOSED MECHANICAL EQUIPMENT WITH BENJAMIN MORE EPDXY ENAMEL 182, MECHANICAL EQUIPMENT NOTES 1, ALL MECHANICAL EQUIPMENT SHALL BE ARI & U, L, LISTED WHERE APPLICABLE AND RATED FOR THE REQUIRED SERVICE, PRESSURES, TEMPERATURES, .AND SHALL BE PROVIDED WITH ALL NECESSARY TRANSFORMERS, SEALS, VALVES, CONNECTIONS, ETC, TO FUNCTION PROPERLY, 2, ALL INSULATION WILL HAVE FIRE/SMOKE RATING LESS THAN 25/50, 3, PROVIDE A MIN, OF 3' CLEARANCE IN FRONT OF ALL 120-240 VOLT RATED AND 4' CLEARANCE IN FRONT OF ANY 480 VOLT RATED PANELS AND DISCONNECTS, PROVIDE ADEQUATE SIDE CLEARANCE PER NEC. 4, PROVIDE- BACKDRAFT DAMPERS ON ALL EXHAUST FANS AND/OR IN LINE FANS, 5, HVAC CONTRACTOR SHALL TEST AND BALANCE ALL MECHANICAL EQUIPMENT AND AIR DEVICES, EXTRACTORS, DAMPERS, ETC, TO PROVIDE THE DESIGN QUANTITIES AS SHOWN ON THE PLANS OR SCHEDULES, PROVIDE T & B REPORT IN ACCORDANCE WITH THE AIR BALANCE COUNCIL STANDARDS, SIGNED AND SEALED BY A REGISTERED FLORIDA ENGINEER, 6. ALL PIPING AND DUCTWORK SHALL BE SLEEVED THRU WALLS, BEAMS, SLABS, ETC, AS REQUIRED AND COORDINATED WITH THE STRUCTURAL ENGINEER, PROVIDE NECESSARY TRANSITIONS AS REQUIRED FOR DUCTWORK INSTALLATION, DUCTWORK AND ACCESSORIES NOTESi 1, ALL DUCTWORK SHALL BE AS FOLLOWS, A) SUPPLY — GALVF SHEETMETAL W/ 2' 3/4 LB WRAP, B) RETURN — GALVF SHEETMETAL W/ 2' #/$ LB WRAP, C) GALV, SHEETMETAL. 2. ALL DUCTWORK SHALL BE BUILT AND INSTALLED IN ACCORDANCE WITH 'SMACNA' STANDARDS AND LOCAL BUILDING CODES, DUCTWORK SHALL HAVE A PRESSURE CLASS OF 2' WGF UNLESS OTHERWISE STATED, 3. PROVIDE TYPE 'B' FIRE DAMPERS WITH ACCESS DOORS IN ALL DUCTS OR OPENINGS PENETRATING FIRE RATED WALLS, TENANT SEPARATION, PARTITIONS, (SEE ARCHITECTS PLANS FOR RATINGS), 4. USE RADIUS RECTANGULAR FITTINGS OR TURNING VANES IN ALL SUPPLY DUCT ELBOWS, CONICAL BRANCH TAKE —OFFS, SPLITTER DAMPERS WHERE INDICATED ON DRAWINGS AND VOLUME CONTROL EXTRACTORS IN ALL BRANCH DUCTS OR DIFFUSER CONNECTIONS, . 5, ALL DUCT SIZES ARE CLEAR INSIDE DIMENSIONS. 6. PLANS ARE DIAGRAMMATIC, IN GENERAL DICT OFFSETS HAVE NOT BEEN SHOWN, 'A/C CONTRACTOR SHALL COORDINATE THESE AS REQUIRED WITH BUILDING STRUCTURE AND OTHER TRADES, 7. SEAL ALL DUCTS, JOINTS AND SEAMS IN AN APPROVED MANNER AND INSURE AGAINST LEAKAGE, 8. TERMINAL AIR DISTRIBUTION DEVICES SHALL BE TITUS AS F❑LL❑WSi A) CD CEILING DIFFUSER MODEL TDC—AA WITH SQUARE OR ROUND NECK, B) PERFORATED DIFFUSER PAS AND PAR, C) RAG RETURN AIR GRILLE MODEL 350FLF A/C PLAN E L E C T R I C A L L E G E N DUPLEX RECEPTACLE 4-PLEX OUTLET IN COUNTER RECESSED DOWN LIGHT TRACK LIGHTING ® PH PHONE OUTLET O JUNCTION BOX (FOR SIGN) ELECTRICAL NOTES, A - 4' 'LITE TRAC' BY PRESCOLITE <W/ 2 FIXTURES - TV 508) B - 8' 'LITE TRAC' BY PRESCOLITE (W/ 3 FIXTURES - TV 508) C - 2' 'LITE TRAC' BY PRESCOLITE (W/ 2 FIXTURES - TV 508) D - 2'x2' RECESSED FLUOR. W/ WARM WHITE LAMP E - 2-TUBE 4' FLUOR, FIXTURE, REFLECTOR 'HOODS' WIRE LAMP GUARDS, MOUNT AT 12' A.F.F. F - RECESSED DOWN LIGHTS 36"X24' TRANSFER AIR I i ts�# t Cuhaci & Petersen Q L1_ ry O U LL z O � f-- U W 0 W O O Z O Z w o (n (n (n Z Ln Q J a- L Li F U.. 0 U Q CL a Q 0 6 0�0�� dZts�/�-E'er �� ��P �c� � 9s�7�9 �f����s - _ . ,�.,,