Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
240 Towne Center Cir 95-2477
., RE�r15fON5: GENERAL. CONTRACTOR, S RESPONSIBILITIES AT TIME OF BID GENERAL NOTES 1, THOROUGHLY. REVIEW DRAWINGS, SPECIFICATIONS, AND LANDLORD TENANT CRITERIA THIS SET OF DRAWINGS SHALL NOT BE COPIED IN WHOLE OR IN PART WITHOUT PRIOR MANUAL AND OR REQUIREMENT$. (IF TENANT CRITERIA MANUAL AND OR LANDLORD WRITTEN CONSENT FROM "PETR0551 ASSOCIATES° REQUIREMENTS ARE NOT INCLUDED IN BID PACKAGE, CONTRACTOR MUST OBTAIN FROM LANDLORD). THIS SET OF DOCUMENTS ARE CONSIDERED AS ONE UNIT AND SHALL NOT BE CONSIDERED COMPLETE OR WHOLE IF DOCUMENTS ARE SEPARATED IN ANY MANNER. 2. VERIFY BIDDING 6U15CONTRACTOR5 HAVE THOROUGHLY REVIEWED DRAWINGS, DOCUMENTS SHALL NOT BE SEPARATED FOR THE PURPOSES OF SUBMITTING A BID SPECIFICATIONS, AND LANDLORD TENANT CRITERIA MANUAL AND OR REQUIREMENTS. PROPOSAL OR FOR THE SEPARATE PHASE OF ANY CONSTRUCTION. • HEALTH AND BUILDING CODES AND 3. VERIFY ALL FIRE, LIFE, SAFETY, HANDICAPPED, THESE DOCUMENTS ARE PREPARED FOR THE USE OF THE GENERAL CONTRACTOR ACCOMMODATE. ITEMS PERTAINING TO THESE CODES SHOULD BE INCLUDED IN BID AND HIS SUBCONTRACTORS AND IN NO WAY, EITHER IN WHOLE OR IN PART PRICE. CONSTITUTE ANY DIRECTION OR INSTRUCTION TO ANY CONTRACTOR WITH REGARD 4. WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DRAWINGS (DO NOT TO CONSTRUCTION MEANS, METHOD5 OR TECHNIQUES. PETRO551 4 ASSOCIATES DOES SCALE DRAWINGS) AND FIELD VERIFICATION SHALL BE MADE BY THE GENERAL NOT INTEND TO EXPRE5-$;ANY OPINION, DIRECTION OR INSTRUCTION OF ANY KIND CONTRACTOR AND OR SUBCONTRACTOR BEFORE BIDDING. ANY DISCREPANCY WHAT5.0EVER A5 TO THE MANNER IN WHICH THE CONSTRUCTION WORK 15 To BE IN DIMENSIONS AND OR DRAWINGS AND OR GRAPHIC REPRESENTATION AND OR ACCOMPLISHED.Q_ ACTUAL FIELD MEASUREMENTS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION UNLESS OTHERWISE NOTED, ALL WORK SHOWN IS TO BE THE RESPONSIBILITY OF OF PETROS51 4 ASSOC. AND RESOLVED PRIOR TO THE SIGNING OF CONSTRUCTION THE GENERAL CONTRACTOR TO PROVIDE TENANT WITH HIGH QUALITY WORKMANSHIP CONTRACT AND OR COMMENCEMENT OF ANY RELATED MATERIAL ORDERING AND OR WORK. AND A COMPLETE TROUBLE FREE STORE OPERATIONAL SYSTEMS. NOTICE OF DUTY OF COOPERATION., ACCEPTANCE OF THESE DRAWINGS AND n E i $ B Y 5. THESE DRAWINGS AND SPECIFICATIONS ARE SUBJECT TO REVIEW AND REVISIONS SPECIFICATIONS CONSTITUTES AN AGREEMENT FOR FUTURE COOPERATION BETWEEN e BY THE LOCAL BUILDING AND HEALTH DEPARTMENTS, LANDLORD, AND ANY OTHER THE GENERAL CONTRACTOR AND PETRO951 4 ASSOCIATES. ALTHOUGH PETROSSI GOVERNING AGENCIES. GENERAL CONTRACTOR IS TO BE AWARE THAT THESE ITEMS 4 ASSOCIATES AND IT'S CONSULTANTS HAVE PERFORMED THEIR SERVICES WITH DUE A x A s c [ T S S MAY AFFECT HIS BID PRICE. CARE AND DILIGENCE, THEY CANNOT GUARANTY PERFECTION. ANY AMBIGUITY OR o. IF STOREFRONT BARRICADE IS REQUIRED BY LANDLORD, THE MATERIALS, DISCREPANCY IN THE USE OF THESE DRAWINGS AND SPECIFICATIONS SHALL BE Architecture, Piarmin& interiors INSTALLATION AND LABOR MUST BE INCLUDED IN BID PRICE. REPORTED TO PETROSSI 4 ASSOCIATES IMMEDIATELY, FAILURE TO COOPERATE SHALL BE SIMPLE NOTICE TO PE'rRo551 4 ASSOC. SHALL RELIEVE PETROS51 4 A550C, 37W CAMM DRM SUrrE 202 1. PETRO651 4 ASSOCIATES WILL BE RESPONSIBILITY OF SECURING THE APPROVAL CONCEPTS FROM RESPONSIBILITY FOR ALL CONSEQUENCES RESULTING THEREFROM. RI RT BEA�CK CA 9�U FROM ALL THE GOVERNMENTAL AGENCIES 4 READY TO OBTAIN THE PERMIT BY G. C. CHANGES MADE FROM THE DRAWINGS AND OR SPECIFICATIONS WITHOUT THE CONSENT � 8— 45 ll OF PETROSSI 4 ASSOC., ARE UNAUTHORIZED AND SHALL RELIEVE PETROS51 4 ASSOC, OF ANY RESPONSIBILITY FOR ALL CONSEQUENCES ARISING OUT OF SUCH RESPONSIBILITIES OF AWARDED GENERAL CONTRACTOR CHANGE($). EACH CONTRACTOR AND SUBCONTRACTOR PARTICIPATING IN THE CONSTRUCTION OF PROJECT 1. THIS TENANT'S SPACE MUST BE BUILT FROM THE CITY APPROVED PRINTS, LANDLORD THIS "TENANT5'5 5PACE" SHALL BE DULY LICENSED AND EACH CONTRACT AND F(EIVNE'i-I L. BUTTS COMMENTS, AND ARE TO REMAIN ON SITE AT ALL TIMES FOR USE BY ALL INVOLVED SUBCONTRACTOR SHALL CONTAIN THE GUARANTEE OF THE CONTRACTOR AND THE TRADES AND INSPECTORS. RESPONSIBILITY TO TRANSFER THE NECESSARY SUBCONTRACTOR THAT THE PORTION OF TENANT'5 WORK COVERED THEREBY WILL ARCHITECT A.I.A.. NOTATIONS MADE BY THE CITY TO THE PRINTS USED BY THEIR EMPLOYEES TO BE FREE FROM ANY AND ALL DEFECTS IN WORKMANSHIP AND MATERIALS FOR THE AVOID ANY PROBLEMS DURING CONSTRUCTION. PERIOD OF TIME WHICH CUSTOMARILY APPLIES IN GOOD CONTRACTING PRACTICES, 2. NO SUBSTITUTIONS OR CHANGES TO APPROVED DRAWINGS CAN BE MADE WITHOUT BUT IN No EVENT LESS THAN ONE() YEAR AFTER THE COMPLETION OF TENANT'S CONCURRENCE OF THE LANDLORD CONSTRUCTION COORDINATOR. WORK. THE AFORESAID GUARANTEE SHALL INCLUDE THE OBLIGATION TO REPAIR OR REPLACE IN A THOROUGHLY FIR5T-CLA55 AND WORKMANLIKE MANNER AND `V 3, GENERAL. CONTRACTOR'S RESPONSIBILITIES SHALL INCLUDE BUT 15 NOT LIMITED WITHOUT ADDITIONAL CHARGES ON ANY AND ALL OF TENANT5'5 WORK DONE OR�' TO PROVIDING A QUALIFIED FULL TIME SUPERVISOR AND OR ERECTOR, FURNISHED BY SAID CONTRACTOR OR SUBCONTRACTOR, OR BY ANY OF HIS SUB- REPRESENTING THE GENERAL CONTRACTOR, WHO WILL BE PRESENT AT ALL TIMES CONTRACTORS, EMPLOYEES OR AGENTS WHICH SHALL BECOME DEFECTIVE BECAUSE WHEN CONSTRUCTION IS BEING PERFORMED IN LANDLORD'5 LEASE SPACE. THIS OF FAULTY MATERIALS AND OR WORKMANSHIP WITHIN THE PERIOD COVERED BY INDIVIDUAL MUST MAKE NI5 PRESENCE KNOWN TO LANDLORD'S ON -SITE FIELD SUCH GUARANTEE (AND OF WHICH NOTICE 15 GIVEN TO SUCH CONTRACTOR OR COORDINATOR BEFORE THE START OF WORK, SUBCONTRACTOR WITHIN SUCH PERIOD) AND THE CORRECTION, AS AFORESAID, \ % OR ANY SUCH MATTER SHALL INCLUDE WITHOUT ANY ADDITIONAL CHARGE \ �. 4, GENERAL CONTRACTOR WILL BE RESPONSIBLE FOR NOTIFYING THE CITY OF THEREFORE ALL EXPENSES AND DAMAGES IN CONNECTION WITH REMOVAL, t SANFORD, FL. FOR ALL NECESSARY PERMITTING COST LICENSING REQUIREMENTS. REPLACEMENT AND OR REPAIR IN A THOROUGHLY FIRST-CLASS MANNER OF `\ ANY OTHER PART OF TENANT'5 WORK WHICH MAY BE DAMAGED OR DISTURBED S PACE V C -1 O 5. ELECTRICAL CONTRACTOR BID PRICE TO INCLUDE ALL REQUIRED CONTROL THEREBY. ALL WARRANTY OR GUARANTEE AS TO MATERIALS AND OR WORKMANSHIP WIRING FOR ALL EQUIPMENT: SUPPLIED AND/OR CURRENTLY EXISTING AT STORE ON OR WITH RESPECT TO TENANT'S WORK 5HALL BE WRITTEN 50 THAT THEY SHALL e,a TOWNE CEN � SPACEE R. INSURE TO THE BENEFIT OF LANDLORD A5 THEIR RESPECTIVE INTERESTS MAYSEMINOLE APPEAR AND CAN BE DIRECTLY ENFORCED BY THE LANDLORD AND FORCES AND CONTACTS SHALL GIVE TO LANDLORD ANY ASSIGNMENT OR OTHER ASSURANCE NECESSARY FLORIDASA%N''FOKr-%D TO EFFECTUATE THE SAME. ! GENERAL CONSTRUCTION SHALL BE COORDINATED WITH ALL CONSTRUCTION BEING FRANCHISE OFFICE MECHANICAL, PLUMBING PERFORMED OR TO BE PERFO'J�Rh1ED BY LANDLORD AND THEIR OCCUPANTS. NO 1 FLAMERS CHAR15URGER5, INC. BUILD.ING MECHANICAL SYSTEMS, INC. CONTRACTOR 05 SUBCONTRACToi�Z-"PARTICIPATING IN CONSTRUCTION. WORK SHALL ��,,� 81ro1 PERIMETER PARK BLVD. 201 (0 MORGAN, SUITE 100 AT ANYTIME DAMAGE, INJURE, INTERFERE WITH, OR DELAY THE CONSTRUCTION OFC9a JACKSONVILLE, FL. 3221ro IRVINE, CA. 92118 LANDLORD OR THEIR OCCUPANTS AND EACH SHALL COMPLY WITH ALL PROCEDURES �,��.� 7 (904) 641-1111 (114) 581-3010 AND REGULATIONS PRESCRIBED BY LANDLORD AND GOVERNING AGENCIES FOR THE INTERGRADTION OF ALL WORK, LANDLORD HEREBY AGREES TO ENGAGE THE LANDLORD OFFICE EQUIPMENT COMPANY SERVICES OF CONTRACTORS WHOSE EMPLOYEES EMPLOYED AT JOB 51TE WILL NOT SEMINOLE TOWNE CENTER T41D DE51GN5, INC. RESULT IN A LABOR DISPUTE, WORK STOPPAGE, OR OTHER DISTURBANCE INCLUDING LIMITED PARTNERSHIP 4949-1& SUNBEAM RD. ANY SUCH DISTURBANCE WHICH WILL INTERFERE WITH THE LANDLORD OR MASTER C/O 51MON PROPERTY GROUP JACKSONVILLE, FL. 32251 LANDLORD OPERATION. LANDLORD MAY TERMINATE ANY EMPLOYEES SUCH DISPUTES, 115 WEST WASHINGTON STREET (904) 443-000o THESE DOCUMENTS ARE THE PROPERTY OF PETRO551 4 ASSOC. AND TENANT. NO IN., IN. 4&204 PART OF THESE DOCUMENTS (DRAWINGS AND SPECIFICATIONS) SHALL BE USED FOR - CONTACT. ROBERT L. NORKEY HOOD SYSTEM ANY OTHER PROJECT EXCEPT FOR THIS PROJECT WITHOUT THE PRIOR WRITTEN (311) 2(03-191ro CAPTIVE-AIRE SYSTEM, INC. CONSENT OF "PETRO551 4 ASSOCIATES", 801 W.STAGE RD. 43/0 PLAN AND SPECIFICATIONS ALTAMONTE 5PARING6, FL 32114 J PETROS51 4 ASSOCIATES (SO�O)825-3143 i1 q 3100 CAMPUS DR. SUITE 202 MENUBOARD NEWPORT BEACH, CA 929,60 / ('I14) 533-3240 POSTERLOID 4301 22 ND, ST• ELECTRICAL LONG ISLAND, NY 11101 UTILITY C,QNN,rT10:N .FEE SPARK ENGINEERING (118)129-1050 _ 3848 GAMPU5 DR. SUITE 218 NEWPORT BEACH, CA 92&(oO DRINK DISPENSER �� (114)833-2210 COKE,U5A. (Sf00>)8�-1-5�40 VICINITY MAP KEY PLAN LEGEND PROJECT DATA ' JURISDICTIONAL AUTHORITIES SHEET INDEX PROJECT ADDRESS FLAMERS BUILDING DEPARTMENT TELEPHONE SERVICE SPACE NO. VC-10 CITY OF SANFORD SOUTHERN BELL TEL. CO. T•1 TITLE SHEET DRAWING: •� = DOOR NO. SEMINOLE TOWNE CENTER 300 NORTH PARK AVE. 500 NORTH ORANGE AVE A-1 FLOOR &EQUIPMENT PLANS p' FORLANDO, FLORIDA PO BOX 1188 ORLANDO, FL. 32801 A-2 STOREFRONT & INTERIOR ELEVATIONS TITLE ' 4 SANFORD FL. 32111 180-2800 A-3 BUILDING SECTIONS & DETAILS ;. A D 00 DOOR L BEL [�-- R DR. GEES ' SE SPADE AREA o00 SQ FT - �Sv (800) 153-0111 DOORS & NO i (4 ) 330 1 A 01 5 A-4 CABINETRY PLAN Ft;AMR3 LEA vc A-5 CABINETRY SECTIONS & DETAILS ' ; s�►u;nole to ROOM NAME SERVICE CODE DATA : FIRE DEPARTMENT A-6 FINISH SCHEDULE A-7 REFLECTED CEILING PLAN & DETAILS Town. , ` e " AND NUMBER 100 TYPE OF GONSTRUGTION IA CITY OF SANFORD FIRE DEPT. aa� ent�. as l'�., as mn fii'�;j%���:" -�+. •�` •1 ".t w �: k'E�1NEY FULLY SPRINKLER 1303 SOUTH FRENCH AVE. ;. r o-r `' w 1 I L:L�, 5A ORD, FL OCCUPANCY GROUP � NF 32 rHEGKED BY: ,'� 0. ` Q g . OVERALL SECTION A "®' MERCANTILE (40-i) 322-4952 PATE, �- 2�- 95 P-1 PLUMBING PLAN & SPEC. FOOD SERVICE PERMITS P-2 PLUMBING ISOMETRICS ISSUED FOR: ,. SECTION T . 3 P OF BU5 4 REVIEW DEEP INESS PARISIAN ; PROFESSIONAL REGULATION M-1 MECHANICAL PLAN & DETAIL �0DIVISION OF HOTELS 4 RESTAURANT FLAN CHECK 50 DETAIL A 400 WEST ROBIN5ON STREET 31DC�ING NORTH TOWER, SUITE 5U9 E•1 GENERAL NOTES & SPEC. E•2 ELECTRICAL LIGHTING & POWER PLANS PERMIT ORLADO, FL. 32801 w� 1 (401) 423-6985 C� ON5TRUCTION UPPER LEVEL INTERIOR ELEVATION 4�2 52B Wun+ll �- 28 CAPTIVEAIRE HOOD SYSTEM DRAUUN BY I f � `•o� t INDICATES LEASE 3 — GAS SERVICE ;SHE T No.: ��wfs���r.►I �� wpw � LINE FLORIDA PUBLIC UTILITIES CO. , 830 WEST 51XTH STREET E•� la+� SANFORD FL. 321-11 7 _... INDICATE5 NEW WALL (401) 322-5133 T KI INDICATE5 EXI5TING WALL (U.N.O.) 74o Towne C&4e EXIT SIGN EXIT �1n J 1 oi8 .Mal Regulglo" auf ants 0 Res!. ()44eflskylte • cIon of goblnb 0000, orla(Adq, LAN APPROVED FOOD SE ICE Date Reviewer of seats'__L___ projects total number Applicant Plans are in compliance subject to: systems. r wastewater s 'I) Connection to approved water and was local codes. state aElldl with applicablestate Compliance w I with all provisos Of Specification work 0 III-10 )/all SCAL.M; 1/4" -. 1'-011 11%,J) I 1 11 ShpAt attached, & PROFESSIONAL REGULATION 0, BUSINESS FLORIDA DEPT. rants, District 11 Division of Hotels and Restau :.F00I)SERVICE, EQUIPMENT LIST SCHEDULE OF REQUIREMENTS Liz Duncan plan Reviewer: LEASE LINE ITEM PTY DESCRIPTION MANUFACTURER MODEL DIMENSIONS HP WATTS PHASE C W H W DRAIN GAS B.T.U. EXHAUST,, SUPPLY WALK-IN REFRIGERATOR' AMER I CAN PANEL, CUSTOM I I 0/�P_0. I & 3/4 SINGLE N/A' N/A 11 1W N/A N/A N/A N/A .2 1 WALK_IN.FRO,EZER,,, AMER I CAN -.-PANEL CUSTOM 2Q I & 1-1/2 SINGLE N/A N/A I' IW N/A'' N/A N/A 1 1 UNDERCOUNTER FREEZER" ',DELFI.ELD 407 :27'X28-1 /a X3�571/2 H I 10 1/4 SINGLE N/A N/A N/A N/A NA �N/A N/A 10 1, 6 DRA T R DRAWER LOW BOY'.'REFRJ6ERA 0 DELFIELD �5108 Io81X3O_5/8'X25-3/4H Ifo" 1/3 SINGLE N/A N/A N/A -N/A N/A N/A N/A 12 1, DROP -IN REFRIGERATED'cbLD,PAN,. DELFIELD 8159 59 -1/2'�X26'X22-1/2'H 1/4 SINGLE N /;A N/A W N/A N/A N/A N/A I DUNNAGE RACK, METRO DR1836P 18' X 36' X 14' H WA N/A N/A N/A N/A N/A N/A N/A N/A N/A 22 4, 3 TIERS'SHELVING UNIT. METRO S18726Z 181 X 721 X 6 2,1 H N/A: WA N/A N/A N/A -N/A N/A N/A N/A N/A 25 `-:�2'. 5 TIERS SHELVING LJN�IT, �.METRO 1,8' X,60' X 74 " H _N/A N/A N/A N?A N/A N/A N/A • N/A, N/A N/A 32 HAND;SINK-DREIP-IN ' -i , . 'ADVANCE DI -1-5 18'z X 12',X 5' H N/A N/A N/A, 1/2, 1/2, 1-1/2, N/A N/A -N/A 'N/A 33 1 , HAND SINK ADVANCE .,.7-PS-60 17' X� 15' X 13' H N/A N/A N/A 1/2, 1/2, 1-1/2, N/A N/A N/A N/A 35 1 3 COMP SINK UNIT� W/.DBL,-1])BRD ADVANCE. -354-ISRUX 91' X27' X 3 6' H_ NIA N/A I/ 2" -1/2, 1-1/2, N/A NIA N/A WA 39 1 SINK PREP TABLE W/DRAWER 'ADVANCE-TABCO TKSS-308 96' X 30- X 36"H WA' N/A 1/2�1 1/2, 1-1/2, N/A N/A `N/A �N/A 42, FRY STATION W/FJLTER 2 X 14BA, 48' x 31-5/8' X =�4'H: 110, 1/2 HP/1700 SINGLE N/A N/A N/A 260.000 !.,N/A N/A 49. 1 ICE MAKIER 6401,.LbS�-W/17QQ LDS' BIN1HQSHIZAKI KM-630-MAB 44�- X 31 1/2' X 46' H 220, 3/4 SINGLE 1/2' N/A 1' IW N/A N/A N/A WA 55-, 1', CHARBROILER MAGIKITCH'N SMB-60, 60' X 33-1/2i k-'171 H N/A N/A N/A N/A N/A N/A -3/4' 200,000 N/A N/A RIDD CECILWARE O4 B-8 ' ' 24X 21-1/2X N/A \1� 4 N/A N/A N/A N/A 45 3/ '8 4. 0000 N/A N/A. 63 1 PRERINSE-UNIT LANCASTER" WM222-12 N/A N/A N/A N/A N/A N/A N/A N/A N/A 64, _,J SLICER UNIVEX 7510 1/3 S I NGLE N/A N/A N/A N/A N/A -N/A N/A -.65-- ", GAS HOSES W/QUICK DISCONNECTS', "HOSE MASTER, 1/2',:�/4',I' 'N/A N/A N/A N/A N/A -N/A NIA N/A N/A �6 6 I- 'FOOD -WARMER WELLS 2 7 - T 09 1 SMP 14-3/4'XP_3-I-/2'XIR-3/8'H 110 1200 SINGLE N/A N/A N/A N/A N/A -N/A. N/A • 67 1 CONVEYOR TOASTER ''SAVORY RB33VS 15-3/4'X23-1/4'116-1/2'H 220 22-QO S I NGLE N/A N/A N/A N/A NIA 'N/A 68, 1, 4 TIERS -DRAWER m [ T CUSTOM CUSTOM, a4l X 241 X 181 H N/A N/A N/A N/A N/A N/A , N/A N/A N/A N/A 69 1 SNEEZE GUARD -'DISPLAY CASE CUSTOM. CUSTOM X 24, X 14' H N/A, N/A N/A N/A N/A N/A N/A N/A N/A N/A 7.0 6 CUP DISPENSERS EZ-ALL PC-1000 7' 11, D - 5-1/2' 1. D N/A N/A N/A N/A N/A N/A N/A N/A N/A 75• �.I EXHAUST HOOD CAPTIVE AIR E 13 FT X�1' 13 FT X 51' X 30" H f 101/220 ',HP / 1000 3 & I PH N/A N/A N/A N/A N/A 5000 CFM 4000CFM 77 1 'FIRE SUPPRESSION. -SYSTEM• ANSUL' ' R - 102 N/A N/A N/A N/A N/A N/A N/A N/A' N/A N/A' 90: 1 FRONT. �COUNTER CARPENTRY BY�GC N/A N/A N/A N/A' N/A N/A .,N/A N/A N/A 91 1 MOP SINK BY PLUMBEk.. BY PLUMBER. N/A NIA N/A 1/2, 1/2, 3` N/A. N/A N/A! N/A. 92 1 EI-ECTPICAL PANEL 13Y ELEC CONTR BY EL_ CONTR' N/A' N/A N/A N/A� N/A N/A _N/A N/A N/A' N/A 93 -1• COKE, RAQS-SHELVING UNIT BY.VENDOR BY OTHERS 3 0' X 18' X 60' H N/A N/A m/A N/A,, NIA N/A N/A N/A N/A N/A 94.,:� 1 COFFEE MAQHINE �:_BY VENDOR. BY OTHERS Ito 1700 SINGLE N/A N/A N/A N/A N/A NfA N/A 95 2 COKE DISPENSER 24' ..WI:DE BY VENDOR By OTHERS 24' X 24.' X 23' H Ito 1/4 SINGLE. 1/2' N/A 11 1W N/A N/A 2, CASH, REGJ:STER BY OWNER Y 17H B U ERS 11.0 -DEDICATED S I NGLE N/A N/A N/A N/A N /A N/A N/A 97 1 MENU -BOARD __BY, OWNER BY. OTHERS Ito 500 S I NGLE N�A� N/A N/A N/A N/A N/A N/A • t. (19 QQ w _z =V 2 64 10IN GI WORK ZONE �/ TI =-Z Ima DISPLAY ZONE 39) II 1 C58 (�9�6) 1 C25 C7 7j`I iI 0 � -- ,I- 1 - 42 JJ "91 an V_ Lf� it LEA5E LINE °gymg. Yuma I � I ISS,UED FOR: I I REVIEW EQUIPMENT PLAN I �'� I ': SCAL.R. 1/4" - P-011 - RFEV1510NS: r SIGN BAND- BACKGROUND I t e PARTITION BY G,C. a t `; CONTRACTOR SIGN CO. 1 i TO SUPPLY 4 INSTALL -` "FLAMERS CHARBROILED -- - - t--- CHARBROILED - I -,--- HAMBURGERS 8 CHICKEN" r --.--!----- HAMBURGERS s -- �-- � — 51GNAGE. SIGN CO. TO SUPPLY LANDLORD W1 © I COMPLETE SHOP DRAWINGS. - - -- - -- & CHICKEN fi _ L - _ D B I B B Y A N A S C I 8 I A I I ArcWtecture, Plar *u & interiors x, EXIST'G. PAINTED PTD. u ` 3'xIV STL. TUBE i NEWPORT BFA(H, CA 660 - -- _ -- +— — TM MQ 833-3M FAX (7W MU45 r - --� to I - NEUTRAL PIER FR9, JEGT - - — BY LANDLORD --� - �- -- (TYPICAL) K�NNETH L; BUTT_. �- ----- CUSTOM "SNEEZEGUARD I rl1CHITECT A.LA 5UPPLIED BY OTHER _—i - --- 4 INSTALLED BY G.C. -}-- --- -- *- --,- - P17717 \{ �< T' T rt" j 1 T � f < <' - K �: ;� � ► - FIN. FLOOR `X, 1k ale P1 nw W B2 W STOREF R. ONT ELEVATION $CALE: I/z" I'-0" � r VERIFY WITH FLAMERS i 12 3/4" , 4 3/4" SIGN 8 BACKER BY GEN CONTR, � wI w EXIST'G.3"xl2" _ � 6%. TUBE ,r: n r r - -- W (PAINTED)wo OPEN t0 FOOD COURT NEUTRAL PIER �_. _ ��'1�'f `'3 z �:/,� tt tr BY LANDLORD i -- %'" ,. L �fi- ^ -, 0 q (BEYOND) r r r J MENU50ARD PLEXIGLA$5 FACES ARE SUPPLIED - _,F__ _ t _ U. — 4 INSTALLED BY TENANTS SIGN MANUFACTURE. - - �- SNEEZE GUARD -, W 0 q COVER ALL. EDGES 4 SIDES W1 COLOR BLACK, �- — — — _ ---- - +' INSTALLED BY TENANTS SIGN MFG. ,�— _. l - 10 0 .4 O MENUIBOARD ELEVATIONS I � � � I k� I' DF�AUJII�G: sti N ws STgREFiRONT ELEVATION �i ELEVATION P2 A(T�, ELEVATION AID INTERIOR ELEVATIONS SIGN BACKER BY GEN CONTR. ,Nr CHFCKED BY: wt < EXIST'G. ,5"x12" DOTE: II ,,` ; ; f5TL,. TUBE /_ . . i-r" L. �r r.�L .1-r.� .•-> >Lt.Kr r-''-' - �tT- --'�Y =-`'7 /�'= /-'`.`� '.fii ''t.�� .!'• - �pelN7�n� - SIDE ELEVATION if % �r ' ME U B BY FLAM RS ,(. i t . % r f -• _� �.-- 1 REVIEW NEUTRAL PIER PLAN CHECK TENANTS SIGN MANUFACTURER WILL SHIP F-IN15HED MENUBOARD TO JOB SITE CxENERr4L CONTRACTOR WILL BE f2E5E'ON51k3L.E FOP, HANpLINC� INSTALLATION. _ i B. HOOD BY LANDLORD --- - - --r - -- -- -- T--' t - BIQDINCx 0 I i t-- _—� $ FIT r CBEYOND) PENT REPORT ANY DAMAGED SHIPMENT A.S.A.P. TO MANUFACTURER. _— — I _ ; - , I �x, <�, �;.. , r— - _ I `c — �— + CONSTRUCTION h DOOR 5EE �W2 �81 5CNEDULE Am2' 4(i� ELEVATION 4 ELEVATION c.aDFllrE: SEMI-A2 MENUBOARD E Lr E 11 AT IIN .7 SCALE: 3/ 11 „ � �� INTER]OR ELEVATIONS 04�. 1/4".= 1' - �" CA, FIL SEMI 195 ,, d.J 1 �. i 1\. 1 1 1 R.../ R /�1,1 i� REVISIONS: LATEX PORTLAND CEMENT REFER TO FINISHED LEGEND MORTAL BOND COAT — FOR GROUT COLOR REaUIRED — r WATERPROOF MEMBRANE PER LAND LORD SPEC. NEW S"x5"x1/2" QUARRY MEMBRANE BOND GOAT TILE FLOOR VERIFY MFG. 'LM 3��a" MTL. STUDS 16" 3e/a", MTL. 5TUQ5 24" (E) WALL O.C. W/ 5i$" GYP, BRD, O.C. W/ 5/a" Gyp. BRD, 5EC. 3/A-3 TNINSE7 MORTAL �30ND r CEILING JOISTS) BED PER CERAMICTILE HANDBOOK n B I s B Y - -- — 1 UNDER SIDE OF : u= " N A 8 c I T _ � FLOOR TILE DETAIL SCALEvao— EXIST'G. DECK a SIGN @ BACKER Architecture, Plwv interiors BY GEN CONTR. i I I i 3= CAMM DEL SUM 202 EXIST'G. V'AV 2-3 5/ " MTL. CLG. bOWPM IfFACU CA 92W 5TL. TUBE - I -- — -� c'� JOISTS Q 16" O.C. �� — TEL 99) M-IM (PAINTED) �__ �i� COL, W/5� " (1•YPE °x" 5/8 GYP. �3D. Ax (na) s -ltas --- (� r---1 ENCLOSURE 8 NEUTRAL PIER i-- {-- _' __ .__i BEYOND _ _ T _ GYP. RD. EA. SIDE 4"x4"xl/4" Br Y LANDLORD Hd0 (BEYOND) 1- - - - — —�- ---1---� - r B TT. _ I CLG. CERAMIC TILE PROJECT LL { - —- --- --�-� - l --T I REFER TO FIN. _ SCHEDULE KENNETH L. BUTTS c`.A. -—' 0 FOR ALL FINISHES ARCHITECT AI ( - SEE HEFT A-6 MTL. STUD WALL 1 �----� I� FO UJALL DET. 5 EE 5EC. I \ /A-3� , ,-, 1 Iit 3/8" RADIUS COVEDp QUARRY TILE BASE , r FOR FINISHES ALCOVE EXIT SEE INTERIOR DOOR WAY � ELEVATIONS E BEYOND N Hf;Z FINISH SCHEDULE FIRE RATED ASSEMBLY UL. c e U465) GZUARRY TILE FLR, cz= v OVER THIN-5ET ADHESIVE SECTION "A" 1/4" I'm0i If WALL BASE DETAIL r 1012 GA WIRE BRACE EA, 51DE WALL a45° ANGLE ATTACH WIRE TO UNDER51PE SECURE TO STRUCTURE OF DECK WITH "HANGTIGHT" FIRE STOP ABOVE SPACE 48" O.C. FASTENER BY LANDLORD EXISTING ROOF DECK r UNDERSIDE OF - UNDERSIDE OF 3-5/S" MTL, EXISTING DECK EXISTING PECK STUDS 16" O.C. REFER TO SHEET A-1 FOR TRIM DUCT ENCLOSURE REQUIREMENTS uj 8 ROOF PENETRATION DETAIL z NEW 3-5/8" MTL. FRAMING W/5/8" w GYP. BP. 'TO FORM CEILING Z -- r OVER SERVICE AREA. 1 I/2"xi 1/2"x3" LONG INDICATES EXISTING o Q 20 GA ANGLE EVERY 46" MTL. STUD FRAMING r 0 O.C. ATAGH TO TRACK W121a — _ BY LANDLORD. u h SELF TAPING TEK 5CREW `Q .j 0 LUZ2 NEW CLG. SEE FIN. � SCHEDULE rn V) V) . C1 G1 DRAWING: 5/8" TYP. "X11 GYP. BRD, EA. SIDE BLDG. SECTION r SEE ROOM FINISH C2 ANDDETAILS 1 SCHEDULE SEE ROOM FINISH ww SCHEDULE FOR FINISH ORSBY�LANDLORD 5EE SHET. A-2 CH HOOREQUIREMENTS FOR MENU BRD. ---� 3 5/8" MTL. STUDS a 16" O.G. CHECKED BY: Q DATE: (o-2"1-95 cv 5/V' TYPE "X" GYP. BD. TO STRUCTURE ABOVE ISSUED FOR: r AND SEAL TIGHT W/ REVIEW Q FIRE 5AFING MATERIAL BY GEN. CONTR, PLAN CHECK (UL. U465) BIDDING �Q PERMIT S? CONSTRUCTION SILL TRACK W1 1/4" (0 DRAWN BY: (Off HIGH COPED BASE .. SHOT PINS w 24" O.G. 6" HIGH COVED BASE TILE AT WALL TILE AT WALLSHEET NO.: r Am3 FIN. FLR, FIN. FLR, FIN. FLR. �ca�: }/2" }_��SCALE; 1/2" � I'-�'� SCALE- 1/�" w I-�CADFISEMI -A3ECTIO �R�WALL 3 WALLSECTION' JOB NO. 42P-0195 .... „ W/ 032 Lr" N PRE55LIRE L.A" I INATE E50TH I rr f �R agnVF� TWF r 0OR STATINGS "THIS DOORS) TO REMAIN UNLOCKED DURING' BU51NE55 WOURS . -� N FACE OF COUNTERTOP FRONT LINE OF COUNTER 5A5E BELOW 0 I PEEP POLE 5UPPL I ED AND IN5TALLED 5Y r- YERlr-Y W/LANDL 5PEC FIN. COLOF 5EE PARDWARE SCPEDULE FOR REQU I REMENT5 "C" LABEL f3/4- FIRE RATED DOS I i r 0/71�0�1-r..-'--� f / / / i/r3 X \�Q i I i I 3'-513/a" I, 2'-o" cs� 2 7 A-2 3 4 SERVING / DISPLAY ZONE 101 211 I 41 _ 011 211 Q r COMPLETE DOOR5 SUPPLIED AND IN5TALLED 5Y GEN, CON. WORK ZONE 102 SCALE: NONE ;. F?ROYIDE,.COKE MACHINE CUT -OUT1 OF 231/2't43fia" VERIFY UJ/: FLAMERS (TYP.) LEASE LINE f PROVIDE NAND SINK CUT-OUT VERIFY W1 FLAMERS SCALE, I/2" REVISIONS: CUTTING BOARD _ ATTACHED AT BACK GRANITE RESIN COUNTER TOP SUPPLIED 4 INSTALLED I SEE PLAN BY CONTRACTOR _ 5NEEZEGxUARD BY OTHERS SEE DETAIL 4 DRINK DISPENSER r AT COUNTER. 4 INSTALL BY EN. CONTR. BELOW CUT-OUT TO —^ BE 23 3/4 ttx 3 B%" MTL. STUD KNEEWALL - 23 3i4" (VERIFY FRONT SEE 5HT "A-311 UJ/ FLAMERS) COLD PAN DROP -IN PROVIDE PLASTIC UNIT, SEE SHEET "F-1" ' / - LAMINATE OVER I'2 D B 1 B B Y \N . .. DOUBLE 3/411 CAB. �° r Pi - 11-011 GRADE PLYWOOD. A M A SECURE COUNTER WHITE WIRE PULLS 1 1/2" CLEAR ! TOP TO WALL Architecture, Plannkn& Interiors ' WD.- 5ULLN06E —� - - \' _ — -- — — — — - 3700 c ;9 D. SUMB � W4 f -�- _ P2 -' NMFW Box, CA YO TEL (714) M-MO SECURE COUNTER FAX ('i14) s-u45 f TOP TO TOP WALL I N N N ii f � PRoJEcr PROVIDE COLD PAN; I I r ! CUT-OUT OF 51"43-1/2" KENNETH"L. BUTTS VERIFY W/PROJECT r ~ FLUORESCENT —I i L — — — — — -� ARCHITECT A.I.A. ARCHITECT ` STRIP LIGHT i - @ 3/411 CAB. GsR. PLY- k _ (SEE ELEC. DUJG.) I WOOD W1 LAM. FIN. Q MARBLE TILE �N MARBLE TILE I' - Q FRONT (TYP.) R2 FRONT (TYP.) I' C " - ----------T--I MA TILE I MALL # L STANDARDS -- TYPE — I MALL TILE fi SECURE BASE J E TYPE 4 g TO FLR. �'. P2 'I •9 B1 r - 4 -1/8" �T 2'-4 I/8" 3t1 4 -1/8" 2'-4 l/8" �3" SECTION 1 SCALE: 1-1/2" = 1'-011 SECTlk-.)N 2 SCALE: 1-1/2" II-011 SECTION 3 SCALE: 1-1/2" 1'-011 - r SILICONE CAULK CABINETRY GENERAL NOTES Q CONNECTION CABINET CONTRACTOR To FIELD VERIFY ALL NECESSARY DIMENSIONS AND THIS SHHEETEET TEE ENLARGED DTL. A WALL ANGLES BEFORE FABRICATION OF CABINETS. 5HOF DRAWINGS WILL 1-i/2" WIDTH � FRONT ` PLYWOOD BACKER NOT BE REQUIRED FOR TH15 PROJECT. ANY DESIGN LAYOUT QUE5TION6 c 3 5ECURED..TO P1 SHOULD BE ADDRESSED TO TILDIN ENGINEERING FOR CLARIFICATION uj 2x4 PLATES IF NECESSARY. tZ VQ %,, PROVIDE SWING DOORS ON 5ACK LINE CABINETS ONLY. IF HEALTHDEFT. '�'_o 4t1x4" CERAMIC TILE - -- _ REQUIRES ON BACK OF FRONT LINE CABINETS CONTRACTOR TO MAKE ��0 SCORED TO.2"x2" ON � -- >�f-- ^:r T-- C" Nam/- __ FROV1510N5. PROVIDE COMPLETE HARDWARE. � w FACE. SEE FIN. 5CHED. u I"' i CABINET INSTALLER TO MAKE CUT-OUTS FOR FIXTURES R ECE55ED IN * o c W4 COUNTER? TOPS IN FIELD, TO A55URE 5E5T PLACEMENT AND CUT. V z a .�\ I� 2x4 TOP PLATES ALL V151BLE FASTENERS IN CABINET MUST BE CONCEALED COUNTER a z r 1 1/2" OAK 5ULLN05E �.- \ ��$" SILICONE CAULKING �; N PAINTED HIGH GLO55 RED 5UNK AND/OR PLUGGED (TYPICAL) � r+ Ix4 BACKER CABINET CONTRACTOR WILL BE RESPONSIBLE FOR THE NUMBER AND W8 'III PLACEMENT OF ALL NECE55ARY BULKHEADS SUPPORTS FOR ALL CABINETS, DRAWING: 3/4' PLYWD. 5U5-5TRATE � SCREWED TO TOP OF CABINET CONTRACTOR TO 115E MAKE CABINET INTERIORS FROM 3/4" INDUSTRIAL CABINETRY SECTIONS 3/4" FL YUJD. 5ACKER i KNEEWALL GRADE PLYWOOD W/LAMINATE FINISH. USE DOUBLE LAYER OF 3/4" INDU5TRIAL AND DETAILS W/FR NCH CLEAT Ir( E f FLUORESCENT BACK C;R,4DE PLYWOOD W/FINISH A5 5FECIFIED ON TOPS W/DROP-IN EQUIPMENT. Pi x DAY LIGHT SUPPLIED CABINET CONTRACTOR TO DRILL ALL NECE55ARY HOLES IN BACK OF 4 INSTALLED BY COUNTER TOPS FOR RUNNING OF ELECTRICAL, CORDS THRU TO INSIDE ` Wg ELECTRICAN OF CABINET. PLUG HOLE W/WHITE PLASTIC GR'.OMETT. CHECKED BY: N �� cT ^A CABINET CONTRACTOR 15 COMPLETELY RESPONSIBLE FOR COORDINATION DATE: (o-2-1-95 c, / W/ALL TRADES AND EQUIPMENT 5UPPLIER, FOR OBTAINING THE NECE55ARY SECURE BOTTOM BULLNOSE-------------------------- ---- --------------------- PIECE IN FIELD EC�UIFMENT CUT SHEETS FOR EACH PIECE OF EG2UfE'MENT IJJHICH DIRECTLY ISSUED FOR: SC�L �" = I'-O" EFFECTS THE CABINET FABRICATION. REVIEW PLAN CHECK BIDDING PERMIT CLEAR ACRYLIC LENS CON57RUGTION DRAWN SHEET NO.: Aw5 CADFILE: SEMI -A5 OVERHANG DETAIL--, 4 SCALE: 3" I, -o JoB No. 42P-0195 ; 3 . I,N I,SH,:. --j-0M H EID ski ' .,;E RESPONSIBILITY "U L E ... .' - .'�..r. '• - RC74MS . - � _ ' .:- � + : ' , :_:: .., ,. . _WALL _ .. _ TYPE DIVISION OF WORK INCLU LLORD CONTR. OWNS OTHERS DIV15lON OF WORK INCLU R LL R O D CONTR . OWNER OTHERS GONST FIN I H N ORTH.. _' SOUTL-� EASY WEST - S T M ICE , �3U (5 NOT LIMITED •DES BUT 15 NOT LIMITED O TTH~?LLOUINC F� INST. FU� IN T FU7JINST. FU�J INST TO, THE FOLLOUINCINST. FU�INST FU dl INST. FURS 14ST. FURE � DEM151NG- WALLS LIGHTS (ALL, U.N.O.) ® 0 U, s GYPSUM BOARD 0 0 TELEPHONE J ACK$- ALL AND COMPUTER CABLE CONDUITS e PA I NT I NG OUTLET5 iALL� 0 I HR. RATED EXHAUST DUCT ENCLOSURE a HOOP EXH. HOOD E MAKE-UP AIR WIRING A ; x p- EQUIPMENT AND PLACEMENTUNLOADING 0 0 THERMOSTAT WIRING 2 0. Lu CEILING (ALL) 0 0 ALL EQUIPMENT .CONTROL WIRING Q V x ' CAPTIVEAIRE-COMPONETS 0 SIGNAGE ALL ITEMS NOT INDICATED ARE STILL . _ t SUIB CONTRACTORS RE5PON515IL ITY GA81NETRY 0 0 STOREFRONT SIGNAGE 0 0 w z Z lu Q _ m �t m Sl r tp _ cv m m r tlJ FIRE PROTECTION/ CAPTIVEAIRE 0 0 MENU50ARD it QUARRY TILE AND O 2 z 1 L 4) 0 z N N �C � z a a z x z z: z� x X =C _t z 2� z O MISC. DECOR ALL ITEMS_NOT INDICATED ARE STILL U p cn cn cA 0 0 cn 0 0 0 0 0 d 0 N 0 0 0 cn 0 N 0 N 0 0 q) 0 `z � � COVED BASE SUB CONTRACTORS RESPONSIBILITY ROOM ROOM u z z z L z z z z z z z z z z z z z z z z z z z _`z z z z z z z z p No. NAMES a�CIA Eu_ FL E iE a: u iT IL u u. u u: E u- 5. u- a u. � FL' iE u- E E E ALL WALL FINISHES PAINTING 0 0 . 141 SERVICE a DISPLAY 0 -" 0 0 � � POURING 2000 P51 CONC. 3-1/211 MIN. THICKNESS FLOOR SLAB �� (0 COVED aUARRY BASE A ZONE DOORS 4 HARDWARE 0 0 8"x8"xl/2" QUARRY TILE 1D2 STOKE0 0 0 0 0 0 0 0 0 ZONE 0 SEWER LINES ALL CABINETRY FIXTURING WITHIN LEASE SPACE WATER LINES 0 ® TELEPHONE EQUIPMENT ! MAN, ONGTRIC ELE AND MAIN i 0 RECEPTACLE COVERS TO MATCH 'afounwo j SURROUNDING WALL FINISH SERVICE PANELS ® � ALL STOREFRONT TILE TELECOMUNICATION WIRING WORK (CABINETRY) .f - "FRP" WA WALL PANELS ALL INTERIOR WALL ® 0 TILE WOW. SPRINKLER SYSTEM "FRP" WALL PANELS LEGEN-D SYMB. PRODUCT; MANUFACTURER NUMBER SIZE COLOR REMARKS -. A/O CADET GREY GROUT F1 QUARRY FLOOR TILE DAL -TILE DAL QUARRY 31>a 8"x5"xl/2" MAYFLOWER RED W/ 1005"� CLUE BACK �%� MAi23LE WALL T1L AMERICAN GLEAN (904):-131-92`l� M 307 �� �� �� 12 xl2 x3/8 NEGRO MAIG2UlNA VERIFY GROUT COLOR W/LAMERS W2 PORCELAIN WALL TILE (INTERIOR COOKING WALL:) CROSSVILLE CERAMICS. f C��S �� " I► 12 xl2 x,32 STONEHENGE-1 uv/ POL. PORCELAIN -FIN.,- UT - GROUT 34`3 22�9 HYDROMENT CERAMIC TILE W3 MARBLE WALL TILE " (INTERIOR WALLS) AMERICAN CLEAN (904) �131.921-1. M 30& �� �� �J IZ xl2 x3/a BOTTICINO FIORITTO VERIFY' GRQUT 'COLOR . W/FLAMERS 4 CERAMIC WALL TILE (FRONT COUNTER FACE)SCORE DAL-TILEI1 (GLOSS FN5H) D-14o2 4"x4"xl/4" 2x2 TEAL ;U5E_ WHITE 'GROUT Wl 1001% GLUE BACK V V VV MARBLE WALL TILE '(FRONT COUNTER) CASA ITALIANA (9.04) 241-3401 VERIFY 12"x12"x3/S" 5REGCIA PERNICE VERIFY GROUT COLOR W/FLAMER5 HIGH GL0.56 ENAMEL PAINT BENJAMIN MOORE 30S02 N/A SUPER WHITE PROVIDE PAINT FROM (0'_0" ABOVE F,F, TO CLG. W7 CERAMIC TILE DAL -TILE DAL (GLO56 FIN15H), K_101 411x4"x1/4" WHITE USE WHITE GROUT Wl- 100%, GLUED BACK HIGH- GLO55 ENAMEL PAINT OVER 1-1/2" OAK BULLNOSE TRIM BENJAMIN MOORE # 1315 N/A RED FINISH W/ NO BRUSH MARKS B1 QUARRY FLOOR TILE .BASE 5AL-TILE DAL QUARRY 310 TRIM Q3o85 (O"x8"xI/2" MAYFLOWER RED SET ON THIN SET ADHESIVE 4 USE AMERICAN ORLEAN CADET GREY GROUT 132 �" TILE BASE G.C. TO PROVIDE MALL'S TILE BASE Cl 2'x4' VINYL .FACED PANELS ARMSTRONG ARMS14ELtJ 321 2'x4'x5/8" WHITE MFG' $ APPLY A5 •PEA SPECS. SEE ER 2/ 5/S" TYPE "X" PAINTED GYP. BOARD 5OFFIT / CEILING BY GENERAL CONTRACTOR BENJAMIN MOORE PAINT 333 02 SEE REFLECTED CEILING FLAN SUPER: WHITE FINISH W/ NO BRUSH MARKS P1 GRANIT RE51N (COUNTER TOP) AVONITE C1-12.00' VERIFY SIZE FLANNEL GRAY INSTALL A5 PER M . GUIDELINES pZ PLASTIC LAMINATE (PREP DOOR SLAB, CAB., INTE ;IORS,. TOPS `,FAGESjMMM WIL50NAR,T - MATTE FINISH N/A DESIGNER WHITE 100ip GLUED BACK PLUMBING ALL ITEMS NOT INDICATED ARE STILL FINISHING AND PAINTING SUB CONTRACTORS RE5PON515ILITY ID STOREFRONT SOFFIT � ALL GAS PIPING FROM METER METAL ACCESS PANELS TO COOKING EQUIPMENT CEILING (UJHEN APPL.) ALL EQUIPMENT CONDENSATE LINES NOOK -UPS (ALL) CA514 REGISTERS SYSTEM lU;ASTE LINES, FLR DRAINS/SINK LANDLORD APPROVED WATER - HOT 4 COOL WTR. PIPING GAS PROOFING MENBRANE (VERIFY) SEAL FLOOR AND 0 ROOL-UP DOOR GRILL MAKE WATERPROOF � STOREFRONT SAW CUTTING FLR. PENETRATIONS FOR NECESSARY FIX. (WHEN APPL. ELECTRIC WATER NEATER 1 LI ALL ITEMS NOT INDICATED ARE STILL MECHANICAL SUB CONTRACTORS RE$F'ON5I5ILITY NEW EVAC SYSTEM UNIT to/LL. APP.Tr-1ERM05TAT $ CONNECTIONS INSTALLATION OF EXHAUST DUCTS 0 0 # ROOF TOP SUPPLIED EOUIPTMEN EXHAUST HOOD SYSTEM it � NEW DIFFU65ER5, ALL DUCTS ® 0 a RETURN -AIR GRILLS ELECTRICAL ALL ITEMS NOT INDICATED ARE STILL SUB CONTRACTORS RE5PON515ILITY MAIN SERVICE WIRING METER SOCKET 4 PANEL5OARD(5) OUTLET WIRING/"J" BOXES 0 0 SWITCHES e WIRING 8 VAV UNIT CONTROL WIRING GENERAL FINISH NOTES Q PROVIDE NEW S"x8"x1/2" QUARRY TILE FLOOR W/(o" HIGH COVED BASE, ON THIN-5ET BASE W/ AMERICAN OLEAN SANDED GROUT COLOR -CADET GREY, VERIFY W/FLAMERS COLOR AND MANUFACTURER TO BE USED. CONTRACTOR TO SUPPLY *4 INSTALL. GENERAL CONTRACTOR SHOULD THOROUGHLY CLEAN CONCRETE FLOOR SURFACE MENBRANE OVER SLAB- AREA BEFORE APPLICATION OF TILE FLOORING,) t�2 SERVICE AREA COOKING AREA WALL TO BE TILED W/ MARBLE WALL TILE TO MAKE UP MAIN BODY OF WALL TILE PATTERN (SEE INTERIOR ELEVATION), GENERAL CONTRACTOR TO SUPPLY AND INSTALL. WORK 4 STORAGE ZONE WALLS TO RECEIVE 4"x4"xl/4" CERAMIC TILE TO &'-S" HI. FROM FLOOR SEE SECTION "A" CHECKED BY: SHEET A-3 GENERAL CONTRACTOR TO SUPPLY AND INSTALL. a PATE- 4-3- J5 r 0 SERVICE AREA TO HAVE NEW 5/S" TYPE "X" GYP. BR, CEILING OVER METAL STUD FRAMING AND SHALL BE FAINTED 155UED FOR: W/2 COATS MIN. GENERAL CONTRACTOR TO SUPPLY AND INSTALL. [REVIEW PLAN CHECK Q WORK. 4 STORAGE ZONE TO HAVE NEW PRELUDE 2'x4' CEILING GRID (WHITE) W/NEW 2'x4'x!5/a" ARMSTRONG ARMSHEILD I I] r �7 rd ni• •iw O ►iqs-' SmmalalI MR WIN m •.�� ►• -• W/ WITH I VCR I VENT THRU ROOF PIPS SCHMOULAM PIPE MATERIALS (SEE 6PEC5) 4/ �'4 a 442 C 4� v 0 v Q� /tl��� � •/ QA QA ��a � SERVICES , ew V�� �� �� �� REMARKS WATER INSIDE 0 OUTSIDE SANITARY INSIDE DRAINAGE OUTSIDE SANITARY -CONCEALED1� VENT EXPOSED +� INDIRECT INSIDE WASTE OUTSIDE GAS INSIDE 0 PROVIDE DIRT LEGS fD EA. CHANGE IN ELEVATION OUTSIDE mxTuRg ROUGH -IN SERVICES ITEM FIXTURE ClLU z DESCRIPTION C oo O 0 > ciQ J.R. SMITH NO. 3150-12, Fs FLOOR 51N CASTE IRON, ACID -RESISTING ENAMELED INSIDE COMPLETE WITH DOME STRAINER, NICKEL -BRONZE I 3/4 GRATE 4 SEEPAGE FLANGE CONNECTION. TP TRAP PRIMER 1/2" P.P.P. NO. P-2, COPPER BODY, ADJUSTABLE, COMPLETE WITH 1/2' COPPER TYPE "L" PIPE TO RECEPTOR. (INSTALL PER MANUFACTURERS RECOMMENDATIONS BEHIND ACCESS PANEL). LOCHINVAR NO. 1-15-I6-052, GLASS LINED, 52 GALLON STORAGE, 15 KW ELEMENT, 4$0 VOLT, 60 W+a WATER I" IN 3/411 CYCLE, 3 PHASE, RECOVERY m 14 GPH AT 100 I HEATER DEGREES F. RISE, APPROXIMATE OPERATING WEIGHT= 650 LBS., COMPLETE WITH RED BRASS NIPPLES. MUST HAVE ASHRAE WA-&2 STICKER. WILLIAMS NO. HL-1800, TERRAZO, COMPLETE WITH STAINLESS 88 SERVICE STEEL BUMPER CAP, CAST 5RA55 DRAIN WITH STRAINER AND CHICAGO NO. 613-1 FITTING WITH PAIL HOOK, WALL BRACE SINK 3/4" 3/4" 3" 2" AND VACUUM BREAKER. WATER HERSEY NO. MVR-50, WALL MOUNTED, PROVIDE WITH I METER REG15TER INDICATING CUBIC FEET. KITCHMN -III SCHMOULE ITEM DESCRIPTION 10-op-liqRV C REMARKS AC Cl OU 3 ty w 0 3 ul X } 1V 0) %5 GAS INPUT (CFH) 32 HAND SINK 1/2" 1/2" 2" 2" PROVIDE STOP 33 HAND SINK 1/2" 1/2" 2" 2" PROVIDE STOP 35 3 COMP. SINK 1/2" 1/2" 2' 2" PROVIDE STOP 39 1 SINK PREP TABLE 1/2" 1/2" 2" 2" PROVIDE STOP 42 FRY STATION 2" 260 PROVIDE G.C. 49 ICE MAKER 1/2" In INSULATE I.W./ PROVIDE STOP 55 CHARBROILER 1 1/2, 200 PROVIDE G.C. 58 GRIDDLE I" 40 PROVIDE G.C. 91 MOP SINK 1/2" 1/2" V 2" PROVIDE STOP 95 COKE DISPENSER 1/2" 1" PROVIDE HALL VALVES t 1. BEFORE COMMENCEMENT OF HOW., THE CONTRACTOR SHALL VERIFY THE EXACT LOCATIONS, ELEVATIONS, AND CHARACTERISTICS OF ALL UTILITIES AND PIPING AND SHALL IMMEDIATELY NOTIFY THE ARCHITECT OF ANY DISCREPANCIES. 2. EXACT LOCATIONS, MOUNTINCx HEIGHTS AND COLORS OF PLUMBING FIXTURES SHALL BE OBTAINED FROM THE ARCHITECTURAL DRAWINGS. 3. TRAPS FOR ALL LAVATORIES AND SINKS SHALL BE TRAP STRAIGHT BACK TO WALL WITH ALL REQUIRED OFFSETS HAPPENING WITHIN THE WALL. 4. ALL PLUMBING WORK SHALL BE INSTALLED SO AS TO AVOID INTERFERENCE WITH ELECTRICAL AND MECHANICAL EQUIPMENT AND STRUCTURAL FRAMING. 5. THE CONTRACTOR SHALL COORDINATE THE LOCATION OF ALL CEILING ACCESS PANELS WITH THE ARCHITECTURAL REFLECTED CEILING PLAN AND THE ELECTRICAL LIGHTING LAYOUT. rc. ALL CLEANOUTS SHALL BE INSTALLED WHERE READILY ACCESSIBLE. THE CONTRACTOR SHALL COORDINATE ALL CLEANOUT LOCATIONS WITH EQUIPMENT, CABINETS, ETC., AND THE ARCHITECT PRIOR TO ANY INSTALLATION. 1. ALL VALVES, UNIONS, ETC, TO BE SAME SIZE AS LINE SIZE UNLESS OTHERWISE INDICATED ON DRAWINGS. s. UNIONS SHALL BE PROVIDED AND INSTALLED AFTER EACH SCREW -TYPE VALVE AND PRIOR TO EQUIPMENT CONNECTIONS. S. ALL EQUIPMENT SHALL BE LATERALLY SUPPORTED IN ALL DIRECTIONS TO RE515T A MIN. OF 20% OF THE EQUIPMENTS OPERATING WEIGHT. 10. ALL WORK AND MATERIAL SHALL BE PERFORMED AND INSTALLED IN COMPLIANCE WITH THE FOLLOWING CODES AS ADOPTED AND AMENDED BY THE INSPECTING AUTHORITY. NOTHING IN THESE DRAWINGS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES OR OTHERS APPLICABLE TO THIS PROJECT. A. STANDARD BUILDING CODE, 1991 EDITION B. STANDARD MECHANICAL CODE, MSS EDITION C. STANDARD PLUMBING CODE, I991 EDITION D. NATIONAL ELECTRICAL CODE, ISW EDITION E. STATE OF FLORIDA ENERGY EFFICIENCY CODE, 1993 EDITION 11. INSULATE ALL HOT AND COLD WATER PIPING AND ALL PIPING AND CONNECTIONS FOR COLD WATER WASTE, REFRIGERATOR WATER WASTE AND COLD CONDENSATE WASTE WITH MIN. 1/2' THICK PREMOLDED FI5ER3LAS8. 12. ALL WASTE AND VENT PIPING SHALL SLOPE AT 2% UNLESS OTHERWISE INDICATED. 13. ALL VALVES, TRAP PRIMERS, WATER HAMMER ARRESTORS OR OTHER EQUIPMENT SHOWN IN WALLS OR ABOVE NON -ACCESSIBLE CEILINGS SHALL BE INSTALLED BEHIND AN ACCE65 PANEL. 14.0 INDICATES EQUIPMENT NOT UNDER THIS SECTION OF SPECIFICATION. THE CONTRACTOR SHALL Bit RESPONSIBLE FOR ROUGH- IN AND ALL FINAL CONNECTIONS. REFERENCES SHALL BE MADE TO FINAL SHOP DRAWINGS FOR EXACT ROUGH -IN AND FLOOR SINK LOCATIONS, DIMENSIONS, AND ELEVATIONS AND SHALL BE ADHERED TO AS CLOSELY AS POSSIBLE. THE CONTRACTOR SHALL PROVIDE ALL TRAPS (CHROME PLATED CAST BRASS), STOPS, SHUT-OFF VALVES, PRESSURE REGULATORS, FILTERS, STRAINERS, GAS COCKS, INDIRECT WASTE PIPING, AND NECESSARY TRIM WHICH MAY BE REQUIRED TO COMPLETE THE INSTALLATION_ COORDINATE ALL PLUMBING REQUIREMENTS WITH EACH EQUIPMENT MANUFACTURER PRIOR TO ANY INSTALLATION OR FABRICATION. (SEE KITCHEN ROUGH -IN SCHEDULE). 15, THE CONTRACTOR SHALL CAREFULLY COORDINATE ALL PLUMBING REQUIREMENTS WITH THE KITCHEN DRAWIW38 PRIOR TO BID. FLOOR SINK GRATES SHALL BE AS INDICATED ON KITCHEN DRAWINGS. lb. ALL CUTTING OF EXISTING FLOORS SHALL BE BY MACHINE SAW CUTTING. HOLES FOR PIPING IN CONCRETE WALLS OR FLOORS SHALL BE DONE USING CORE DRILLING EQUIPMENT. li. CONNECTION BETWEEN INCOMPATIBLE MATERIAL$ ABOVE GRADE AND INSIDE BUILDING SHALL BE MADE WITH 2 DIELECTRIC UNIONS SEPARATED BY A 12" SECTION OF RED BRASS PIPE. 18, ALL FLOOR PENETRATIONS SHALL BE SLEEVED, SEALED, FIRESTOPPED AND WATERPROOFED. ALL PIPING SLEEVES SHALL EXTEND A MIN. 4' IN HEIGHT IS. WATER HAMMER ARRESTORS SHALL BE PROVIDED AND INSTALLED PRIOR TO EQUIPMENT CONNECTIONS, NOTE : PROVIDE AMTROL MODEL $T EXPANSION TANK SIZE PER MANUFACTURER RECOMMENDATION SEISMICALLY BRACE WATER HEATER SHUT OFF WH VALVE (TYP) i TIPRV VALVE W/ I DRAIN TO SERVICE SINK NOT WATER / 14 GA. STEEL $TRAP, SECURE TO 3/6' THIe OUTLET ---� X 6' W. STEEL PLATE ANCHORED TO MIN. 3 STUDS W/ 3/$' ANCHOR POLT6 OR LAG UNION (TYP) SCREWS (NUTS a BOLT$ FOR STEEL STUDS.) COLD WATER INLET T^ i\ WATER HEATER WALL . 3/4' DRAIN TO SERVICE SINK AS HIGH AS POSSIBLE firPLATFOF41 AS REQUIRED BY CODE AND LOCAL AUTHORITIES PLATFORM PER SLOG DEPT REQUIREMENTS AND 6TRUCTURAL STANDARDS NOTES (SEE ARCH.) I. PIPE SIZES TO BE SHOWN ON PLANS AND EXTENDED FULL SIZE To WATER HEATER CONN. 2. FOR EXACT LOCATION OF DROPS TO WATER HEATER (SEE FLOOR PLAN) 0 ■I■I�I� WATOR AND GA6PLUMBING LAN 1/4" S 1'-0" 21 I '01010-volm SS 91 WASTS AND VENT PLUM51NG PLAN 1/4" = 11-0" COMP i (1 AUTO -GAS SHUT-OFF VALVE E3EL. CLG. VALVE PROVIDED BY KITCHEN CONTR. AND INSTALLED BY PLUMBER ® 1 1/2" G ON, TO 1 1/2" G MANIFOLD Q 1/2" H 4 CH ON. Q P.O.C. CONN. NEW 1 1/2" CW TO EXIST. i 1/2"CW ASV. CLG, SEE GEN, NOTE " 1 �5 EXIST. 11/2 "CW ASV. CLG, ® PROVIDE 1 1/2" G FROM GAS METER BANK AT APPROX. 125 FT.. FIELD VERIFY. 1/2" CW ON, 8 1" H 4 CW ON. ® REMOTE WATER METER READOUT DISPLAYING IN GALLONS X 100 AND CONFORMING TO THE AMERICAN WATER WORKS ASSOC. 4 LOCAL CODE RE&MTS. METER READOUT SHALL BE LOCATED IN THE CORRIDOR BEHIND THE TENANT'S SPACE TO THE, RIGHT OF ITS DOOR Q + `12" A.F.F. APPROX. GAS DEMAND COOKING = 500 CFH TOTAL = 500 CFH T.D.L. = 125 FT. 4" GH —Z 10 P.O.C. CONN. NEW 4" W TO EXIST. 6" GW BEL. FLOOR SEE GEN. NOTE a 1 it EXIST. W GW BEL. FLR. 12 P.O.C. CONN. NEW 3" V TO EXIST, 3" V ASV. CLG. SEE GEN. NOTE 0 1 13 W.C.O. 14 F,C.0. 15 P.O.C. CONN, NEW 3" W TO EXIST. 6" GW BEL. FLOOR SEE GEN. NOTE 0 1 1� PROVIDE 4" P.Y.C. PIPE BETWEEN COKE RACK AND D 15PEN5ER BELOW FLOOR FOR 5YRUP LINES, CAULK 4 SEAL BOTH ENDS NOTE- - ALL PIPING: SHALL BE PER LANDLORD'S STANDARD CRITERIA. P.V.C. PIPING CAN NOT BE USED BELOW THE FLOOR. THE SPACE BELOW THE FLOOR 15 A RETURN AIR PLENUM FOR THE LOWER LEVEL TENANT LEASE AREAS. - A LANDLORD DESIGNATED CONTRACTOR SHALL BE EMPLOYED BY THE TENANT TO INSTALL THE SPRINKLER SYSTEM. - THE SPRINKLER SYSTEM SHALL BE FULLY CHARGED AND OPERATIONAL WHEN THE CONTRACTOR 15 OFF THE SITE. REVISIONS, Architecture, Planning, Interiors 3M CAMPUS IDS. SLM M N11 WFORT BFACK CA 916f,Q TM (714) 83'-n40 FAX (714) MH45 6 MORGAN SUITE 100 IRVINE CA 9271E TEL. 714-587-3070 FAX, 714-380-7446 PROJECT w i L4 03:Q i L4 03:Q U z CLQ (j)C(j) DRAWING PLUMBIIIN43 (PLAID CHECKED BYi DATEi 6-29-95 CADF;LEI JOB NO, 0 fz AIR D I STD? I UT I N SCHEMU1.5 C1aM MAX NECK MAX. BP• 6YM. MF,R. 4 MODEL. EvIZ i TYPE DAMF'i:R RE;MARIGs3 CAPACITY VELOCITY N.C. , DROP -I KRUEGER EGC-5 22' X 22" 135O 350 30 103 EGG -CRATE W/ OBD ' ALUMINUM T-I 22" X 46" 2100 - LEI N SYMBOL AE55. DESCRIPTION 5YM80L ABB. DESCRIPTION >® $AD SUPPLY AIR DUCT PD PREMRE DIFFERENTIA!. SWITCH C!9 RAD RETURN AIR DUCT a 6 WITCH ® 06A OUTSIDE AIR — RL — M_ F6 RMRANT LIQUID cf�g EAD EXHAUST AIR DUCT — R5 — R5 REFRIGERANT 6UCTION ---' 500 BDD BACKDRAFT DAMPER — CD — CD CGNDEN5ATE DRAIN (L) LINED DUCrWORC O.C. O.C. GN CENTER ® CD CEILING DIFFUSER EX16T. EXISTING 5 RAR RETURN AIR REGISTER 9 POC POINT OF C2+eCTICN ® EAR EXHAUST AIR REGISTER TK THROAT [ljK 6WR 610EWALL SUPPLY REGISTER I.D. INSIDE DIMENSION O VTR VENT THIN! ROOF O.D. CUT61DE DMEN6ICN FC FLEXIBLE COtr`NECTICN W/ WITH +--to AFD AUTOMATIC FIRE DAMPER 61M %HEFT METAL -{- _+ MVD MANUAL YOLUME DAMPER 6/6 STAINLE66 STEEL 1 0 1 CBD QUADRANT BALANCING DAMPER GC GENERAL CONTRACTOR DL DOOR LOUVER (i— — —Si EX16T. TO REMAIN ILC UC UNDERCUT DOOR 3/4' EXIST. TO BE DEMOLISHED T $TAT THER'IOSTAT Q COMBINATICN 6MGKE/ FIRE DAMPER H H. 6TAT W11DISTAT 6MOKE DETECTOR BT BT BY-PASS TIMER 1) T6 TEMPERATURE 6EN6OR 4550 CFM FROM MALL 4550 CFI" I EXHAUST AIR AC SYSTEM THROUGH KITCHEN HOOD KITCHEN "�' „- ,�► UPBA\ ST KITCHEN--� EXHAUST _ FAN REPLACEABLE GREASE'; ABSORBING MEDIA ROOF PROTECTION SYSTEM (GREASE GUARD OR APPROVED NEW EXHAUST HOOC GREASE DUCT ENCLOSURE. SEE ARCH, SHT FOR DETAIL (TYP.) CLEAN -OUT W/ ACCESS PANEL (12" X 12" MIN 12" X 11" GREASE DUCT CONNECTION DOWN TO 12" X 11" HOOD CONNECTION BELOW. CONTR. Ti VERIFY DUCT CONN. SIZE d LOCATION W/ HOOt MFR. PRIOR TO INSTALLATION (TYP. OF 2) NOTES - ALL NEW DUCTWORK ROUTING TO BE VERIFIED IN FIELD PRIOR TO - ALL EQUIPMENT TO BE LOCATED AS DESIGNATED BY LANDLORD INSTALLATION ON BUILDING STRUCTURAL PLANS - ALL GREASE DUCTWORK SHALL BE SLOPED A MINIMUM OF 1/4' PER - ROOF -TOP EXHAUST FAN TO BE PROVIDED BY OTHERS FOOT TOWARDS THE HOOD. - ALL GREASE DUCTWORK SHALL BE CONSTRUCTED OF A MINIMUM OF 1(o - FOR CONTROL SCHEMATICS SEE KITCHEN DRAWINGS AND SHT. M-2 GAUGE BLACK STEEL, W/ ALL JOINTS WELDED. - FLEX DUCTWORK SHALL BE 5'-0' MAXIMUM IN LENGTH - CERTIFIED AIR BALANCE CONTRACTOR TO PROVIDE CERTIFIED AIR - FINAL CONNECTIONS TO THE LANDLORD SYSTEM FOR CONTROLS SHALL BALANCE REPORT TO LANDLORD BE PERFORMED BY LANDLORD AUTHORIZED AGENT AT TENANT EXPENSE. - ALL EXHAUST OUTLETS SHALL BE A MINIMUM OF 20-0" AHAY FROM ALL FRESH AIR INTAKES, PLUMBING VENTS, d FLUES I. ENTIRE INSTALLATION SHALL CONFORM TO THE REQUIREMENTS OF THE 1991 STANDARD MECHANICAL CODE, 1991 STANDARD BUILDING CODE, AND ALL OTHER APPLICABLE CODES AND REGULATIONS. 2. COORDINATE ENTIRE INSTALLATION OF THE HVAC SYSTEM WITH THE WORK OF ALL OTHER TRADES PRIOR TO ANY FABRICATION OR INSTALLATION. PROVIDE ALL FITTINGS, OFFSETS, AND TRANSITIONS AS REQUIRED FOR A COMPLETE WORKABLE INSTALLATION. 3. COORDINATE THE LOCATIONS OF ALL CEILING DIFFUSERS, REGISTERS AND GRILLES WITH THE ARCHITECTURAL REFLECTIVE CEILING PLAN, ELECTRICAL LIGHTING LAYOUT AND ARCHITECTURAL ROOM ELEVATIONS. 4. COORDINATE THE LOCATION OF ALL ROOF OPENINGS AND THE LOCATION OF ALL ROOF MOUNTED EQUIPMENT WITH THE STRUCTURAL AND ARCHITECTURAL PLANS PRIOR TO ANY INSTALLATION. PROVIDE THE EQUIPMENT WEIGHTS, AND PLATFORM AND CURB SIZES. 5. ALL EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE EQUIPMENT MANUFACTURER'S RECOMMENDATIONS. PROVIDE ALL FITTINGS, TRANSITIONS, DAMPERS, VALVES, AND OTHER DEVICES REQUIRED FOR A COMPLETE WORKABLE INSTALLATION. 6. MAINTENANCE LABEL SHALL BE AFFIXED TO ALL MECHANICAL EQUIPMENT AND A MAINTENANCE MANUAL SHALL BE PROVIDED FOR THE OWNER'5 USE. 1. CONTROL SCHEMATICS ARE FOR SEQUENCE ONLY, REFER TO ELECTRICAL DRAWINGS AND SPECIFICATIONS FOR ALL ELECTRICAL DEVICES REQUIRED. 8, ALL. LINE AND LOW VOLTAGE WIRING SHALL BE INSTALLED IN CONDUIT. ALL CONDUIT AND LINE VOLTAGE WIRING, INCLUpINCa FINAL CONNECTIONS, SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR AS INDICATED ON THE ELECTRICAL DRAWINGS OR SPECIFIED IN THE ELECTRICAL SECTION OF THE SPECIFICATIONS. ALL ELECTRICAL WORK E-4ALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES AND REGULATIONS OF ALL GOVERNING BODIES HAVING JURISDICTION THEREOF. 9. E INDICATES ITEMS FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR A$ SHOWN ON THE ELECTRICAL DRAWINGS OR SPECIFIED IN THE ELECTRICAL, SECTIONS OF THE SPECIFICATIONS. 10, M INDICATES ITEMS FURNISHED AND INSTALLED BY THE MECHANICAL CONTRACTOR AS SHOWN ON THE MECHANICAL DRAWINCs8 OR SPECIFIED IN THE MECHANICAL SECTION$ OF THE 6PECIFICATION6. 11, ALL DUCTWORK SHALL BE SHEET METAL CONSTRUCTED OR SPIRAL, ERECTED, AND TESTED IN ACCORDANCE WITH THE MOST RESTRICTIVE OF LOCAL REGULATIONS, PROCEDURES DETAILED IN THE ASHRAE HANDBOOK OF FUNDAMENTALS, OR THE APPLICABLE STANDARDS ADOPTED BY THE SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL A550CIATION CONTRACTORS NATIONAL ASSOCIATION. KITCHEN EXHAUST SHALL COMPLY WITH NFPA-Wo. 12. DUCTWORK HANDLING CONDITIONED AIR SHALL BE INSULATED OR LINED. SUPPLY DUCT INSULATION SHALL BE 2" THICK, 3/4 LB./CUBIC FT. DENSITY. RETURN DUCT INSULATION SHALL BE I' THICK 3/4 LB./CU.FT. DENSITY. ALL DUCTWORK EXPOSED ON ROOF SHALL BE INTERNALLY LINED WITH 1.5' THICK, 1.5LB./CU5IC FT. DENSITY DUCT LINER UNLESS OTHERWISE INDICATED OR SPECIFIED. ALL DUCT SIZE$ ARE SHEET METAL SIZES. ALL DUCT JOINTS SHALL BE SEALED PER U.M.C. CHAPTER UD REQUIREMENTS. 13. MANUAL VOLUME DAMPERS SHALL BE PROVIDED IN ALL DUCT BRANCHES TO INDIVIDUAL DIFFUSERS, GRILLES AND REGISTERS. 14, ALL EQUIPMENT, DUCTS, PIPING, AND OTHER DEVICES AND MATERIALS INSTALLED OUTSIDE OF THE BUILDING OR OTHERWISE EXPOSED TO THE WEATHER SHALL BE COMPLETELY WEATHER -PROOFED. 15. BEFORE BIDDING ON THIS NOW, THE CONTRACTOR SHALL MAKE A CAREFUL EXAMINATION OF THE PREMISES, EXISTING EQUIPMENT AND SERVICES. HE SHALL DEFINITELY DETERMINE IN ADVANCE, THE METHODS OF INSTALLING AND CONNECTING THE NEW EQUIPMENT WITH ITS ASSOCIATED DUCTWORK, THE MEANS TO BE PROVIDED FOR GETTING THE EQUIPMENT AND MATERIALS INTO PLACE AND SHALL MAKE HIMSELF THOROUGHLY FAMILIAR WITH ALL OF THE REQUIREMENTS OF THE PROJECT. 1(o. BEFORE COMMENCEMENT OF WORK, THE MECHANICAL CONTRACTOR SHALL VERIFY THE EXACT LOCATIONS AND DIMENSIONS OF ALL EXISTING EQUIPMENT AND ELECTRICAL SERVICES IN THE AREA OF NEW CONSTRUCTION AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES. 11, ALL DIMENSIONS SHOWN. ON THESE PLANS ARE APPROXIMATE AND MUST BE CONFIRMED ON SITE. REVISI❑NS, Architecture, PLuming, Interiors 3100 CAMPUS DR. SUITE 202 NEWPORT BEACH, CA 92(oro0 TEL. (114) 833-3240 FAX (114) 833-1145 NwAm B U= L_ ID 2 N G 9 MIN Ak HM Ul Ak I I MiNnAoffibmcp SYSTEMS INC. CONSULTING ENGINEERS 6 MORGAN SUITE 100 IRVINE CA 92718 TEL, 714-587-3070 FAX, 714-380-7446 PROJECT UQ Z� 0O U cr 0 W Z IL (j) W Q 0) (1) DRAWING, MECHANICAL PLAN CHECKED BY, DATE, 6 -28-95 ISSUED FOR, DATE, REVIEW PLAN CHECK BIDDING PERMIT C❑NSTRUCTI❑N SHEET N❑,, I r r r CADFILE, � J❑B N❑, A. ELE. �N'R A L� T CONTRACTOR SHALL APPLY FOR ALL PERMITS. AND INSPECTION --REQUIRED BY LEGAL AUTHORITIES 2. ALL WORK AND`' MATERIALS SHALL BE IN FULL COMPLIANCE WITH -THE LATEST AND MOST STRINGENT APPLICABLE CODE CODE OR REGULATION, 3. CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR ANY ADDITIONAL COSTS FOR MATERIAL OR LABOR TO COMPLY WITH THESE CODES OR REGULATIONS. CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR THE CONDITION OF THE PREMISES ON WHICH THE WORK IS PERFORMED AND FOR THE SAFETY OF ALL PERSONS AND -,PROPERTY DURING PERFORMANCE OF THE CONTRACT. 5. ALL EQUIPMENT AND MATERIALS SHALL BE LISTED, LABELED AND INSTALLED PER RECOGNIZED ELECTRICAL TESTING `LABORATORY.' 6. 'ALL WORK SHALL: BE GUARANTEED FOR A PERIOD OF ONE YEAR ,FROM DATE OF'ACCEPTANCE BY OWNER. 7, . DESIGN DRAWINGS ARE DIAGRAMMATIC ONLY AND SHALL BE FOLLOWED AS CLOSELY AS ACTUAL CONSTRUCTION CONDITIONS WILL PERMIT. 8 NOTHING ON THE DESIGN DRAWINGS SHALL BE DEEMED AS TO VIOLATE THE LATEST AND MOST STRINGENT APPLICABLE CODES OR REGULATIONS. 9. •.ANY ERROR, OMISSION OR DESIGN DISCREPANCY ON THE SHALL BE BROUGHT TO THE ATTENTION OF THE ELECTRICAL DESIGNER FOR CLARIFICATION OR CORRECTION BEFORE CONSTRUCTION. 10. ALL OPENINGS AROUND ELECTRICAL PENETRATIONS THRU FIRE RESISTANCE RATED WALLS, PARTITIONS, FLOORS OR CEILINGS SHALL BE FIRE STOPPED USING APPROVED METHODS AS DETERMINED BY CODE OR REGULATION. 11.. ,'-,PROVIDE INDICATES ITEM TO BE FURNISHED, INSTALLED AND CONNECTED. 12,. ALL GROUNDING SHALL BE IN FULL COMPLIANCE WITH NATIONAL ELECTRICAL CODE. INCOMING SERVICE SHALL BE PER UTILITY 'GROUNDING COMPANY REQUIREMENTS, 13. UNDERGROUND CONDUITS SHALL BE SCHEDULE 40 PVC WITH SCHEDULE 8Q PVC. -SENDS AND STEEL'RISERS.. ALL UNDER- GROUND PVC CONDUITS SHALL CONTAIN A .GROUND CONDUCTOR, :.,AND SHALL BE SIZED PER CODE REQUIREMENT. 14. ALL PANELS SHALL BE PANELBOARD WITH BOLT -ON TYPE CIRCUIT BREAKERS, UNLESS NOTED AS LOAD CENTERS, WHICH ARE PLUG-IN TYPE BREAKERS. 15 : 'ALL FUSED DISCONNECTS SHALL BE FUSED PER NAMEPLATE UNLESS NOTED. CONTRACTOR SHALL SUBMIT CATALOG CUTS OF MAIN SWITCH - 5OARDS BEFORE PLACING ORDERS AND PURCHASE. 17. ALL CONDUCTORS SHALL BE COPPER TYPE THW, THWN, XHHW, ='600V INSULATION UNLESS OTHERWISE NOTED. 18. ALL WIRING DEVICES SHALL BE SPECIFICATION GRADE. 19,:• ALL CONDUITSHALL COMPLY WITH THE REQUIREMENTS OF UNDERWRITER'S LABORATORIES. CONDUIT SHALL BE RIGID GALVANIZED STEEL BELOW OR IN CONCRETE SLAB, OR IN WET LOCATION. CONDUIT SHALL BE SUPPORTED. ACCORDING TO CODE. ALL EMPTY CONDUITS SHALL.INCLUDE PULL WIRE. 2Q..': FL,EXIBLE CONDUIT SHALL BE USED FOR FINAL .CONNECTION TO MOTORS AND OTHER VIBRATING EQUIPMENT.' EXPANSION COUPLINGS SHALL BE USED AT BUILDING EXPANSION JOINTS. 21. NON METALLIC BUSHINGS OR INSULATED METALLIC BUSHINGS SHALL BE PROVIDED FOR ALL CONDUIT TERMINATIONS 22. CONTRACTOR SHALL COORDINATE AND. VERIFY MECHANICAL EQUIPMENT CONTROL AND WIRING REQUIREMENTS WITH MECHANICAL CONTRACTOR BEFORE CONSTRUCTION. 23. ALL LIGHTING FIXTURES AS SPECIFIED ARE OR APPROVED EQUAL CATALOG CUTS OF SUBSTITUTIONS SHALL BE SUBMITTED TO ARCHITECT FOR APPROVAL BEFORE CONSTRUCTION. 24� PROVIDE ILLUMINATED EXIT SIGNS AS REQUIRED„ WITH SELF _SELF CONTAINED EMERGENCY BATTERY PACK AS ACCEPTED BY FIRE MARSHAL. 26. ALL OUTSIDE BUILDING SECURITY AND PARKING LOT LIGHTING SHALL BE CONTROLLED BY TIMESWITCH, OR TIME SWITCH CONTROLLED CONTACTOR. TIME SWITCH SHALL BE TORK #7000 SERIES OR EQUAL 24-HOUR, 7-DAY ASTROL DIAL, DAY OMITTING DEVICE. 26, 'IT IS THE INTENTION OF THE PLANS AND SPECIFICATIONS TO TO COVER ALL THINGS REQUIRED TO MAKE A COMPLETE AND OPERATIVE SYSTEM. CONTRACTOR SHALL FURNISH ALL LABOR MATERIALS, EQUIPMENT, OR MISCELLANEOUS SERVICE REQUIRED TO ACCOMPLISH THIS RESULT. 27. CONTRACTOR SHALL BID THE PROJECT AS INDICATED AND 'SPECIFIED ON THE DRAWINGS. WHEN SUBSTITUTING MATERIALS OR EQUIPMENT OTHER THAN AS. SPECIFIED ON THE DRAWINGS CONTRACTOR SHALL SUBMIT CATALOG CUTS AND AMOUNT OF CREDIT FOR SUBSTITUTION TO BID, FOR APPROVAL. 28. CONTRACTOR SHALL CONTACT SERVING' UTILITY COMPANIES FOR APPROVED ENGINEERING DRAWINGS BEFORE CONSTRUCTION. 29, ' ALL NOTES AND SCHEDULES LISTED. ON DRAWINGS OF OTHER SECTIONS OF THIS PROJECTWITH REFERENCE TO ELECTRICAL CONTRACTOR OR ELECTRICIAN APPLY TO THIS SECTION OF CONTRACT. 30. ALL ELECTRICAL WORK NOTED ON AC AND PLUMBING DRAWINGS TO BE DONE UNDER THIS SECTION. 31, SUBMIT 6 COPIES OF SHOP DRAWINGS FOR APPROVAL WITHIN 35 DAYS OF AWARD OF CONTRACT. CONTRACTOR SHALL VERIFY DIMENSIONS, OF EQUIPMENT AND MAKE SURE THEY COMPLY WITH ALL APPLICABLE CODE REQUIREMENTS RELATING TO CLEAR WORKING SPACE AROUND EQUIPMENT PRICE TO SUBMITTING SHOP DRAWINGS. 32., SUBMIT 6 COPIES OF MATERIAL LIST FOR APPROVAL WITHIN 35 DAYS OF AWARD OF THE CONTRACT. THE.'RIGHT IS RESERVED TO SUBMITTAL OF ANY SAMPLES OF FURNISHED MATERIAL IF DEEMED NECESSARY BY THE OWNER. 33. SUBSTITUTION OF' ANY MATERIAL OR EQUIPMENT SHALL BE ,,APPROVED BY ARCHITECT BEFORE INSTALLATION. 34.' BEFORE FINAL ACCEPTANCE OF, WORK CONTRACTOR IS TO INSURE , ;ALL EQUIPMENT, SYSTEMS ARE INSTALLED AND FUNCTIONING PROPERLY BY PERFORMING REQUIRED FIELD -TESTS. r: - fflft SYMBOLS ::- DESCRIPTION ' FLUORESCENT FIXTURE RECESSED OR SURFACE MOUNT I10 Q - INCANDESCENT FIXTURE WALL OR CEILING MOUNTED EXIT LIGHT - MOUNTING AND DIRECTIONAL ARROWS AS INDICATED ON PLANS AND FIXTURE SCHEDULE.' - NIGHT LIGHT FIXTURE DUAL LITE # DL-2 MOUNTED AT 7'-6" --- - - FLUORESCENT FIXTURE STRIP OR PENDANT INDUSTRIAL TYPE. 0 - LIGHTING FIXTURE TYPE DESIGNATION. _ - --- DUPLEX RECEPTACLE: 20A-125V-2P. 2W GROUNDING TYPE. GFI DUPLEX RECEPTACLE: 20A-125V-2P, 2W GROUND FAULT INTERVPTION TYPE. -Q QC TELEPHONE OUTLET, MODEM, COMPUTER DATA WITH 3/4" CONDUIT TO ABOVE CEILING. - -- -- ----- --- -__--- TOGGLE SWITCH, 20A-125V. FLUSH MOUNT AT +48" OR AS NOTED SUBSCRIPT AT SYMBOL INDICATES THE FOLLOWING: 2- DOUBLE POLE K- KEY t- MANUAL TIME SWITCH 3- THREE WAY P- PILOT LIGHT 4- FOUR WAY A , B, C, D, FIXTURES CONTROLLED & QUANTITY OF SWITCHES. DISCONNECT SWITCH FUSED AS NOTED DISCONNECT SWITCH, NON -FUSED -_ _- - - ---__- - MOTOR OUTLET ---- ----- -- --- ----- --- ----- ---- MD: MAIN DISTRIBUTION PANEL ---- ---- -_ - �] -_ o - -- _- -`-----_- _- LIGHTING AND APPLIANCE PANEL PLYWOOD BACKBOARD FOR MAIN TELEPHONE TERMINATION CONDUIT RUN CONCEALED BELOW FLOOR OR GRADE C�] --- -- CONDUIT RUN CONCEALED .ABOVE CEILING OR WALLS `v CONDUIT ONLY CONCEALED IN EQUIPMENT BY EQUIPMENT CONTRACTOR. WIRING TO BE DONE BY ELECTRICAL CONTRACTOR. -- -- - _-- - CONDUIT RUN EXPOSED-_ --- --_ ---- - ' TELEPHONE CONDUIT 3/4" MINIMUM CONDUIT STUB -UP CONDUIT STUB -DOWN T -------Q D i_zzzl" HOMERUN TO PANEL, HATCH MARKS INDICATE NUMBER OF #12 WIRES IN CODE SIZE CONDUITS. -----(� HOME RUN TO PANEL WITH 2#12 WIRES IN CODE SIZE CONDUITS. C.O. T CONDUIT ONLY WEATHER PROOF .- HORSEPOWER- WP HP - - M — 5 0---� MANUAL 70 A WITH AL OVERLOAD PROTECTION. L MO R STARTER WI THERMAL VERL D - E- _- JUNCTION BOX O --------------------- -------- THERMOSTAT � M . S. B - ------ ._--- --- -- - MAIN SERVICE SWITCHBOARD METER. FIXTUR-E S MOUNTING LAMPS a FIX - TUBE WA/TT MANUFACTURER CATALOG NUMBER / ¢ Q � NO / x 3 a w a TYPE VOLT D A a 4D,p 112 /120 METALUX/2GP-440, 2'x4' RECESS FLUORESCENT WITH ENERGY SAVING LAMP AND ELECTRONIC BALLAST. 11 , / 20 / EMERGENCY EXIT LIGHT WITH SELF CONT, BATTERY PACK. ® 2 j 120 PAINT EXPOSED SURFACE TO MATCH ADJACENT FINISH. 20 0 -'/ 20 i 20 EMERGENCY LIGHT FIXTURE WITH BATTERY BACK-UP AND TWO HEAD LAMPS. 2Q -D 0 / 1; 30 ' LITHOLIER #8056-CLIF-7226, COMPACT FLUORESCENT ! DOWN LIGHT CLEAR REFLECTOR. 30 e��6 0 HALO #L2740 LOW VOLTAGE, HI-TECK TRACK SYSTEM WITH TRACK AND STEM ACCESSORIES. E 1 75 / 11;/120 75 QP� / J, e ALL FIXTURES TO BE APPROVEP BY OY`NER/ARCHITECT BEFORE FURGHA5E, fair r VOLTAGE 120/208 VOLTS /a •r�E L �• L," LOCA f1ON SEE PLAN 3-PHASE, 4-WIRE 1 f•I MQUNTirJG FLUSH BUS 225 AMPS. MA14,ML 0 DING NO €-2 . I VOLTS • 'AIdFS. CKT BUS CKT I I VOLTS AMPS i DESCRIPTION _ REC L'G A B _� C AMP P NO CONN NO (AMP I A B --C LTG ((REC I DE`7CRIPPON REFRIGERATOR 1 10001 20 1 1 4__ 2 3 2U 2000 --�- I I EXHAUST FAN WARMER - 1 1200 20 1 3 - -1- 4 13 20 ! I - - 2000 COLD PAN 1 1 1000 20 1 5 - -�- 6 13 20 ' 2000 -- - ------ CORE MACHINE 1 10001 20 1 7 Z i ' 20 300 i HOOD _ICI -ITS CASH REGISTER 1 - i 200 20 1 9 t-4 '0 1 ! ; 20 j 20� I L'G,7D CON T COFFEE MAKER r I- I 1200 20 1 11 --12 1- 0 �--- —�---; —�- - - ! 200 I I ; TEL. RECPT_ t t ICE MACHINE i 100C �20 2 13 14 i 1.2; !%60 �— - GEn; RECEPTS. -- -- ✓ -- -� —i - + - -t —r ----� ---------- -- -� I 1000 120 2 15 -�- 16 1 20 1 i000j I I bAv EJx -- - - ;-! --j --L --T----- FREEZER ! I t i 500 20 11 17 t8 '' 26 j 50CI MENU BOAPD TOASTER -�� 12g0� 20 2 19 - 20 1 20 50: j — CAB_ L1(H rl, I - 1200 20 2 21 -} i 2- ; ' 20 1961 1' ' GE" L'Gi i i5 SLICERI i 1G00 20 1 23 f- -�-} �24 1 20 i 150, ' I TRACH L"_,Hr FRYER 1 2400 30 1; 25� r 26 ? 2029i l I - ' I E�1 -✓-i' S `,'WALK-Ir1 FREEZER � ! 2000 ( 30 � 2 27 4-i 28 2000 130 2" 9 30 ; I vV11 i<-I(tJ �v0Lt_R 2000 . 30 21 51 I 32 I- -j -- - j 2000 30 33 - - { 34 j WALK--1`, „-JLER I O�i� 500 20 1 35 ff « I I I GA,F'j r'E�:S ER 1 20020 1 37 :�8 --- �— - - 001<MAC-;'NE I �- ; '`?OU 20 11 39 SIGN I 1400 30 1 11 - -I - 1 42 ! TOT L 88001 2600; 8500 2t0 3696f .3-7 0I VOLTS + AMPS: DUS A 13,65C DEMAND FAC'CR `", x '_CL (VA) 2„i46 x 2 1 PUS B 12,296 DE11,14NL FACr0R ii,J% X NO^,'_C_ ('-'A' ':6,'S0 - 36,15C SUS C 12,250 TOTAL 38,703 VA TOTAL 38,196 3--P-IA`;E, 108 AMPS. * LOCKABLE BREAKER # *TIMER GONTROLLER I VOLTAGE 277/480 VOL IS 1� L ®� LOCA"IGN SEE PLAN'-- 3-PHASE, 't 4-'HIRE 4a� , MOUNTING FLi!SH s BUS 125 AMPS. MAIN MLO DNG � 0 E-: DESCRIPTION XF?,1R T-1 /OLTS AMPS. C1 RF__.LTG A B 15000� AMP 1100 P C!, r NO 1 1 BU5 I CKT I 1 I C7NN ! 110 jP -'�--r ; 13, AMP V�JLTS AMOS. B I i I I LT REC `lAi'.- C i 1E000 I 100 3 3- I 2 I - ^ 13 30ii 30 I� 6000 6000j :-EA'ER - - - I 15000 �00 31 I 5 6 ! 3 t-- 30 ! SPACE 4 tt I - --1 8 -j4"I 1- i-I 12 I I j F ACE i 1 I I TOTAL 1500 01 15000 I 15000 ` 6000 6000-`- 1 VOLTS + AMPS: BUS A 2..000 DEMAND ACTOR 125 :*: LC_ ('✓A' x t._'S =- VOLT"' + AMP>: BUS A 21,000 DEMAND FACTOR 100% x NUNLC( (VA). VOLTS * AMPS: BUS A 2!,000 TOTAL �;3,I 0U vA . 1OTAL F>3,000 3-RHA'SE, 76 AMPS. GONNEGTED LOAD NO. DEMAND ON KITCHEN LOAD 1 XFMR LOAD CALCULATION ITEM DESCRIPTION CONN. LOADS (W) DEMAND LOAD (W) REMARKS 1 LIGHTING LOAD 2,046 2,557 125% 2 KITCHEN LOADS 36,150 23,497 65% NEC 3 25% LGST. MTR.. 1,500 1,500 — TOTAL 39,696 27,554 45KVA XFMR SIZE TENANT LOAD CALCULATION ITEM DESCRIPTION ' CONN. LOADS (W) DEMAND LOAD (W) REMARKS 1 XFMR T-1 39,696 27,554 SEE ABOVE CALC. 2 WATER HEATER .18,000 18,000 100% DEM. 3 A/C `UNIT ;5,200 5,200 100% DEM. TOTAL 45,554 55A & 480V EXISTING MAIN SERVICE SWED. IN ELECTRICAL ..�. ....,.. , �.1.6 , .v... , . , .....� , +..,.... , .,f.o.... , ........ , ...,� , III — EXISTING 2�1`1/450 VOLT, 3d>, 4—WIRE BUS ---------------- ROOM i 100AS, 3P I (BY LANDLORD) • I10OAF,31P (BY LANDLORD) . I • EXISTING 1 1/4"C-ADD 311 CU.+ L. , 1 #6 GND. (BY CONTRACT( R). . . r-l"— EXISTING CONDUIT STUB -UP ABOVE 100AS CEILING EXTEND TO MAIN DISCONNECT. 100AF 3P PANEL-H 70A 1 (22,000AIC) 3P J 1-1 /2-C-3#1 45KVA XFMR T-1 El'_�y 480-120/208 V., 30, 4-WIRE p— Y CO 1 3POA J NCrj r- 2"C-4#3/0 TC TRACK L LIGHTS. J SIGN PANEL-L I� THE ELEGTRIGAL EG2UIPMENT SHALL WITH STAND THE MAXIMUM AVAILABLE FAULT CURRENT AT THE MAIN 5WITGHBOARD. SINGLE LINE DIAGRAM N.T.S. NOTE: IF WALL AMOUNT PREWIRE, OR FIELD INSTALLED FIRE SYSTEA,,I AdICROS'WITC14 TER&IINALS SHOVING FACTORY WIRING M1UST BE FIELD WIRED NPUT PC�lc'R I --r------ � 3 11IRE, 3 P:+ASE ,a00C MAX IhF^JT P LLjrR 'L vaC � 1 1 c�u::13' PsY, CtJ n., :IK= .:Ct4DIT ;fir C:RCGSJIITC T �:GW. S I:SW WATT51 _IGuT CCN'ROL I �s�-_--, (, t '=IRE Sy JTEr'' Ard"Gr W : 7 I T �r I L -.�-+ 3Ju CN �..� -_ T ; IT O C RQ. ;:�RLU I -- . BREAKER P ..2:+iCER BF�..f`F R•— �= 4L, u.awtEFd9.n '-S i r9'CRO1 FOR F 5_^ FGR 5 UTDCWI Id_1 i-I r - �I- I ?nrILDI G -RE T Lr-.-__ �t�Ll I-N-il _:�---- --- aAraE_ ---1-=--------� FOR 3Gr\AL - I __ e r r-- --- -r i I ' t ` � I N`_i + wr TIOL'7L- FwJ ♦I�, ij-. - I��3 A-'i9ATcr' I LISTED I 131 3 �+FMIp0R00oiIJIT�gNr: 11 _$JRHSt `N9 A ON rJr? *' I I �t �, _ TO t�F ETD FOB F11E._�_EL1$fl94 I I ( I ( _ _ lSN;ANT RIP DE %iGc --��RCL NCTE DRY CONTACT RE,_Av _ _ _ C- RED I _. f: 3 ' E AU3- I� T'7 Tr^—(--c't.-•� NO - DK F-4- LG3 T Fa%N Sv�TC1. O RJ-_� -_.� NC - LT. BLU r,XN- r tocinoN "nere _;i i uw s ITc�s�f' 1 WIRIN F R_11__X 1 _ X 6' HINGED Dp� or R _ c.>ru �r �� I Rt'Y SCdll' N'I z COVERED ELECFRICAL L _ —_ m 11 1/2"G0-3#10 TO PANEL—L, 0IRGUIT5 2, 4, 6 21 1/2"GO-3#12 TO PANEL—L, GIRGUIT5 5, 10 3� 1/2"G0-3#12 TO HOOD EXHAUST FAN WITH 30A5, 15 AMP5. FRN-R FU5E AT FAN. NOTE: FOR OTHER ELEGTRIGAL REG2UIREMENT5 AND FIRE ALARM AND SMOKE CONTROL SYSTEM REFER TO, FOOD GOURT DESIGN CRITERIA. -41 SPARK ENGINEERING PROFESSIONAL ELECTRICAL ENGINEERS 3848 Cornpus Ur , Su;te 218 Piewport 8aoch, CA 92660 lei:' 114) 833-2,IC Fox.(714) 8`.2-1913 REVISIONS: ArcNtectwe, PWw in& Interiors 3M CAMS DR SUrr E 202 PI ffOgP BE" CA 91M TEL (Ili M-U40 FAX CM) 0-IM PROJECT KENNETH L BUTTS ARCHITECT ALA. , z w UCie uj J �O0 F Lu J w0 U =2 a: DRAWING: ELECTRICAL ht� SCHEDULES/ NOTES/LEGEND/ SPECIFICATIONS CHECKED BY: DATE: 6/27/95 s 155UED FOR: r REVIEW PLAN CHECK BIDDING PERMIT CONSTRUCTION DRAWN SHEET NO.: Eml CADFILE: "FL — I2 - JOB NO. 52P-0295 3 j _!V is REVISIONS: L-39 L-12,14 VERIFY LOCATION -OF PANELS BEFORE - ROUGH -IN FOR ANY INTERFERENCES RECEPT. -1 10/1, 18"AFF RECEPT. 110 11 1200W COKE MACf�lN.E_______, 8'-AFF, COF EE MAKER LI N -L PN H 14 u I IFT�F�L 4 1 L-19,21 I_XtMR za _j DEDICATED RECEPT.110/1. WORK ZONE A A CASH REGISTER, 18"AFF L_ I u!"'jil -2,4,6 L-11 ,d_PHONE102 B r_c= 60" A SERVING I JB, 20811, 78-AFF D E DISPLAY ZONE F It : — I E B y 1 1 (4 WIRES), ICE MAKE I — 0 AND HEATER REGISTER L-23 JB. 110/1, FN CLG, DOOR LIGHTS GA!5H CA5H 01 TER L- 13.15 L RECEPT. 110Z1, 1/3 HP 18"AFF, DROP -IN COLD PAN L-31,33 ArcNtecttse, Pknrin& Interim p RECEPT. 110/1, 113HP /2" CO-3#10 OINDICATES 4x4 JUNCTION BOX L-8.10 18w-A-FF, REFRIQERATOR UNDER COUNTER. TM CAMPUS DF. SUrM 2M L-37 JB, 208/1. FM CLO, WALK -IN COMPRESSOR llox & EVAPO NEWPM EIPACK CA 9M L-16 RATOR. ALL CONTROL WRING D 11 1 BY ELEC. cm. O INDICATES 3/4" EMPTY CONDUIT TEL (71,0 833-3240 L-3 L-1 TO RUN COAXIAL V41RE. L-17 RECEPT. 110/1, 1/3 HP FAX (714) MR45 48- AFF, SLICER 11 1 JB. 110/1, FN CLO, DOOR LIGHTS i AND HEATER COUNTER. DEDICATED RECEPT.110/1 INDICATES PHONE JACK UNDER VAV BOX T CASH REGISTER, 18-AFF Ili L-27,29 f- FLLC� RECEPT. 110/1, 1200 W I CO-3#10 @ INDIGATE5 5/4" GONI?UIT WITH FROJECT I FOOD WARMER 2 PAIR PHONE WIRE. KENNETH L BUTTS RECEPT. 110/1, 18"AFF RECEPT. 1104, 120OW ARCHI71ECr Abk -AFF, FRYER COKE MACHINE & 1/2 HP, 18 IN COMPRESSOR INDICATES LOCATION OF PHONE JB, 208Z1, FM CLG, WALK- TERMINAL ®THE BACK OF THE HOUSE. 30AS & EVAPORATOR. ALL CONTROL-W—RING 141 30AF 14 ! (By ELEC. CTR. 3P L TYPICAL INSTALLATION OF PHONE JAGK5 AND L-9 CASH REC-215TER5 REOUIREMENT5. COAXIAL WIRE TO BE PULLED BY THE GASH REGISTER RETAILER. ki L-25 H-2,4,6 ALL OTHER WORK BY ELECTRICAL CONTRACTOR, RECEPT. 110/1, 1/4 HP 1/2"C-3#10 18" AFF, U'CTR FREEZER JBI 20813, FM CLG TO EXHAUST HOOD'S CONTROL BOX. RUN CONTROL WIRES TOROOF MOUNTED EXHAUST &.SUPPLY FANS ( 3 & 2 HP) RESPECTIVELY. ALSO INTERCONNECT TO MALLS F.A.P. PER REQUIREMENTS AND ALL LOCAL & STATE CODES. ALSO CONNECT TO GAS SHUT-OFF VALVE AND SHUNT TRIP TO CUT ALL POVVER/UTILITIES IN CASE OF FIRE. ALL WRING, CONTROL ETC BY ELECTRICAL CONTRACTOR, WHO M U S T ALSO REVIEW DETAILED DRAWING OF MANUFACTURER CAPTIVE-AIRE FOR A FULL SPEC OF SCOPE OF WORK. c) ELECTRICAL POWER PLAN SCALE: 1/4"=lp-O)p JUNCTION BOX LOCATIONS DETAIL N.T.S. 21 aG L-24 L-18 WORK ZONE z L-26 Lu 102 I u < Lu z LEASE LINE 0 0 26 PNL-L PNL-H > J 22c, 2 d 6 0 UJZ2 LLI 22c z 5 22c j 22ab L-22 v)(A V) 215 NL FF DRAWING, L-41 J-BOX FOR SIGN 22c I I ( (( i i I I ELECTRICAL (VERIFY LOCATION) z ► POWER AND LIGHTING 22ab 22c I PLANS SYSTEM SERVING 22c ' it lIf - -- DISPLAY ZONE —71 7) L DASHED LINE CHECKED BY; Y,5, 26 INDICATES BOX NL 22ab — - -------------- COOLER BELOW-, DATE: 4/2a/e5, MENU BOARD, Illo-I I 22c 155UED FOR: II I1> z / —A\ REVIEW \lj_w il D 1 26 PLAN CHECK 0 22c 5IDDINC-s LEASE LINE PERMIT CONSTRUCTION L-20 DRAWN J-BOX FOR CABINET LIGHTS (VERIFY EXACT 5HEET NO,, LOCATION IN FIELD) SPARK ENGINEERING PROFESSIONAL ELECTRICAL ENGINEERS Em2 3848 b, S,j 2 18 Ne&poft be:)O Fa, -14') _952-1 -118 CADFILE: ELECT" RLCAL -,,'LIGHTING PLAN SCALE: 1/4"=V-0 JOB NO. F>2 F 02'B5 now I HOOD INFORMATION TABLE MAX, AIR REQUIREMENTS , HOOD CONFIGURATION EXHAUST RISER SUPgLY RISER HOOD C❑❑KING HOOD N0. MODEL ❑D LENGTH E G TEMP. C❑NST• END T❑ BACK TO SIZE CFM/ TOTAL SIZE I CFM/ TOTAL QTY. RISER S.P. EXH. CFM QTY. I RISER S.P. SUP. CFM END BACK W L W L TYPE 1 4524 13' 0' 600 2 12 17 2275 1.000 4550 - - - - - - STAINLESS N ❑� DEG. i STEEL HOOD INFORMATION TABLE HOOD FIRE FILTERS LIGHTS FIRE SYSTEM ELECTRICAL INFORMATION HOOD NO, CABINET QTY. HT LEN TYPE QTY. TYPE WIRE TYPE SIZE LOCATION PRE -WIRE LOCATION # OF LOCATION WEIGHT GUARD (GALLON); PACKAGE # SWITCHES 1 LIGHT SW. 1 LEFT 1 20 t 16 SS BAFFLE 4 INCAN - PYR❑CHEM 2.4/2.4 FC Left 31111002 FC Left I FAN SW, FC Left 822 0 S/W SW, LBS, 7 20 :` 20 0 OTHER SW, Hnnn ArrFS.�nRIFS TART F BACK -RETURN ' STAND-OFF WRAPPER BACKSP�ASH END PANELS FINISHED HOOD BACK LEFT RIGHT i TOP BOTTOM FINISHED BACK NO, WIDTH LENGTH HEIGHT TYPE LOCATION HEIGHT LENGTH INS SIDE HEIGHT WIDTH WIDTH INS BACK LENGTH WIDTH INS WIDTH INS WIDTH INS LEFT �; LEFT - - - - FRONT 1 - - 3 - - - 3 - 6.0 SHOP RIGHT - - - - ELECTRICAL_ INFORMATION t CI COTDIr'Ai IKICr1D►AATIOKI TARI L' I NO. TAG DIAGRAM # PREWIRE SWITCH QUANTIT STARTER HOODS FIRE FAN STARTERS SUPPLIED START. CTRL. VOLT, PHASE H.P. HEATER BACK DRAFT L❑CATION L❑CATION SWITCHE LOCATI❑ SYSTEM jYPE i BY VOLT, DIAGRAM # DAMPER FC Left 1 Lights 1 ES-1 - 31011002 Hood #1 FC Left 1 Fans 0 S/W Etec Box 1/ PYR❑CHEM bhoust CAS 120 208 3 3.00 - - Hood #1 p Other EF-1 l SPECIFICATIONS: THREE PHASE ELECTRICAL PACKAGE (SEE TABLE FOR, DETAILS) HOODS SHALL HAVE A PRE -WIRED ELECTRICAL CONTROL PACKAGE LOCATED IN THE UTILITY CABINET TO OPERATE THE FAN PACKAGE. WIRING OPTION SHALL INCLUDE A STAINLESS STEEL SWITCH PANEL CONSISTINy OF ONE LIGHT SWITCH AND ONE RED -LIGHTED FAN SWITCH FOR EACH SET OF INTERLOCKED FANS, A HINGED COVERED JUNCTION BOX WITH RELAY FOR SUPPLY SHUTDOWN, A NUMBERED INPUT/OUTPUT TERMINAL STRIP, AND A WIRING DIAGRAM. ADDITIONALLY, THE MICR❑SWITCH FOR ANSUL SHUTDOWN SHALL BE PRE -WIRED TO J-BOX. A STARTER/OVERLOAD ASSEMBLY FOR EACH FAN WILL BE LOCATED IN THE UTILITY CABINET, ONE ELECTRICAL IC❑NDUIT DROP FROM THE FAN PACKAGE SHALL BE CONNECTED TO THE NUMBERED TERMINAL STRIP. CONDUIT BETWEEN HOOD AND FAN PACKAGE SHALL BE SUPPLIED BY THE ELECTRICAL CONTRACTOR, EXHAUST FAN CEF--D j FAN INFORMATION TABLE FAN UNIT NO. FAN UNIT MODEL # EXHAUST FAN = SUPPLY FAN TAG CFM S.P. RPM H.P. PHS VOL� BLOWER MODEL/ ' TAG CFM S.P. RPM H,P. PHS VOLT M❑DEL HOUSING MODEL 1 NCA24BFT FX24BFT EF-1 4550 1,50 904 3.00 3 f 208 ,- - EF-1 1 I FIRE Q SYSTEM 1-4 Hood #1 ELECTRICAL C❑NTROL. BOX FAN & LIGHT 12,00 SWITCHES 1 FEATURES: - ROOF MOUNTED FANS A - RESTAURANT MODEL EXHAUST FAN - UL 762 & UL 705 , D - WEATHERPROOF DISCONNEgT - THERMAL OVERLOAD PROTECTION VENTED CURB - HIGH HEAT OPERATION (4Q0°F) I<> - GREASE CLASSIFICATION TESTING. E - CSA APPROVED (NCA MODELS ONLY) GREASE GARD (BY OTHERS) (AROUND BASE OF CURB) NORMAL TEMPERATURE TE4T R <DIA) GREASE DRAIN ❑N FAN EXHAUST FAN MUST OPERATE CONTINUOUSLY 20 GAUGE WHILE EXHAUSTING AIR Aj 400°F (204°C) ALUMINIZED STEEL UNTIL ALL FAN PARTS HAVE REACHED CONSTRUCTION THERMAL EQUILIBRIUM, AND WITHOUT ANY 3' CONTINUOUS FLASHING AIR INLET OPENING DETERIORATING EFFECTS TO THE FAN WHICH ROOF OPENING DIMENSIONS C WOULD CAUSE UNSAFE OP�RATI❑N. < �%� ^ ��� (D-2) X (D-2) DUCTWORK BETWEEN <� ``\ /��� ABNORMAL FLARE-UP TES F EXHAUST RISER'ON HOOD EXHAUST FAN MUST OPERATE CONTINUOUSLY D D AND FAN (BY OTHERS) WHILE EXHAUSTING BURNM GREASE VAPORS AT 600°F (315°C) FOR A f ERIOD OF EXHAUST FAN DIMENSIONAL DATA 15 MINUTES WITHOUT THE FAN BECOMING CURB DIMENSIONAL DATA DAMAGED TO ANY EXTENT;THAT COULD CAUSE MODEL A B C R (DIA) WEIGHT < LBS > NCA24B 46 26.5 33.5 25.5 190 AN UNSAFE CONDITION. i MODEL D E NCA24B 32.5 20 9 I 8.00 112.00 - - I I I EXHAUST 171.00 O I STEEL HANGING F8.00 ANGLE (TYP.) 12,00 - - I II EXHAUST 17.00 J-BOXES & CONDUIT n PRE -WIRED TO LIGHTS �- 78.00 ' 13' 39.00 3' STANDOFF HANGING ANGLE w i 3' STANDOFF tj Z c 48.00 0 45.001 I , PLAN VIEW 13' MODEL 4504-ND EXHAUST HOOD + i i I SPECIFICATIONS: ND MODEL CAPTIVE-AIRE HPODS ARE BUILT IN CDMPLIANCE WITH THE MODEL ND IS A CANOPY HOOD WITH OPTIONAL REAR DISCHARGE MAKE-UP AIR THROUGH A REAR PLENUM (NDBR), NFPA #9� THE HOOD COMPONENTS SHALL BE FABRICATED OF AND ONE DR NDRE OF STAINLESS STEEL, #3 OR #4 POLISH, ON ALL EXPOSED SURFACES. CONSTRUCTION SHALL BE IN ACCORDANCE WITH NFPA 96. I THE FOLLOWING: ' THE HOOD SHALL BE PROVIDED WITH HANGING ANGLES ON EACH NSF #136p END OF THE HOOD. AN ADDITIONAL SET OF HANGING ANGLES B.D.C.A. #86-48 WILL BE PROVIDED FOR HODS GREATER THAN 12' IN LENGTH. + I.C.B.O. #4a16 THE HOOD SHALL BE FITTED WITH U.L. CLASSIFIED BAFFLE E' TYPE FILTERS OR S/STEEL HIGH VELOCITY CARTRIDGE FILTERS. S.B.C.C.I. #675 EACH FILTER SHALL BE EASILY REMOVABLE FOR CLEANING. THE j FILTERS WILL DRAIN THE GREASE INTO A SLOPED GREASE DRAIN U.L. CLASSIFICATION #91G6 SYSTEM WITH REMOVABLE 1/2 PINT CUP FOR EASY CLEANING. U.L. LISTING I#41E3 HOOD LIGHTS SHALL BE U.L. LISTED SUITABLE FOR GREASE HOODS AND SHALL BE SUPPLIED WITH PLASTIC COATED GLOBES. EACH LIGHT WILL ACCOMMODATE UP TO A STANDARD 100 WATT ; I BULB. ALL LIGHTS WILL BE PRE -WIRED TO JUNCTION BOXES ON TOP OF THE HOOD, HOOD DIMENSIONS SHALL BE AS SHOWN ON DRAWINGS. SIRE SUPPRESSION SYSTEM I I I I II ,1 I I '• I I I I I 15' I 1 11' I I I 11' I I II II L------------------I-------- J- - - -- -----j 16,00 - --+ 20.00 20.00 ----j 10.00 I 66.00 I 16.00 8.00 39.00 I 78.00 �0OD # 1 i ' NL-D2 NL-D2 i OO L------ 3p ---. ---�L--------0 O�5 0 2�8 28 @ 8 8 33 7 9 NL-Fl NL- 10 16.00 20.06 20.00 10.00 66.00 16.00 8.00 eLS-R NLS-R NLS-R NLS-R NL-F2 NL-F2 i FRYER 4' L x 21' Gas Radiant Char -Broiler WARMER h Proximl 60,00' L x 24.00' D GRIDDLE 18'L x 24'D 24'L x 24'D FILTER High Proximity 16'L x 24'D FRYER 4'L x 21' h Proximi y EXHAUST RISER 10OW VAPORPROOF INCANDESCENT LIGHT 4 8' 45' 9' CEILING 4' 6' HIGH WRAPPER r 2V 16 U.L. CLASSIFIED BAFFLE -TYPE :F GREASE FILTERS SLOPED GREASE DRAIN WITH REMOVABLE CUP 11.5' MIN 48' MAX 78' EQUIPMENT BY OTHERS TYP. I SECTION VIEW MODEL 4524 - ND EXHAUST HOOD SPECIFICATIONS i THE RESTAURANT FIRE SUPPRESSION SYSTEM SHALL BE THE PRE-ENGINEERED TYPE WITH A FIXED NOZZLE AGENT DISTRIBUTION NETWORK. IT SHALL BE LISTED WITH UNDERWRITERS LABORATORIES, INC. (UL) THE SYSTEM SHALL BE CAPABLE OF AUTOMATIC DETECTION AND ACTUATION WITH LOCAL OR REMOTE MANUAL ACTUATION. ACCESSORIES SHALL BE AVAILABLE FOR MECHANICAL OR ELECTRICAL GAS LINE SHUT-OFF APPLICATIONS• r THE EXTINGUISHING AGENT SHALL BE A POTASSIUM CARBONATE, POTASSIUM ACETATE -BASED FORMULATION DESIGNED FOR FLAME KNOCKDOWN AND SECUREMENT OF GREASE RELATED FIRES, IT SHALL BE AVAILABLE IN PLASTIC CONTAINERS WITH INSTRUCTIONS FOR LIQUID AGENT HANDLING AND USAGE. THE REGULATED RELEASE MECHANISM SHALL BE COMPATIBLE WITH A FUSIBLE LINK DETECTION SYSTEM. THE FUSIBLE LINK SHALL BE SELECTED AND INSTALLED ACCORDING TO THE OPERATING TEMPERATURE IN THE VENTILATING SYSTEM, THE FUSIBLE LINK SHALL BE SUPPORTED BY A DETECTOR BRACKET/ LINKAGE ASSEMBLY. i Job Name! FLAMERS - SEMINOLE TOWN CTR System Size: PCL-240/240 Tank System - Total System FP = 14,00 Hood # 1 13' ON Long x 45" Wide x 24" High Duct # 1 Size: 12' x 17' Duct # 2 Size: 12` x 17" NOTES - FIELD PIPE DROPS AS SHOWN SLEEVING, ELBOWS, TEES, AND NOZZLES SUPPLIED BY CAS - RELOCATE NOZZLES IF FLOW PATTERN IS BLOCKED BY SHELVING, SALAMANDERS, ETC. - MAXIMUM 9 ELBOWS IN SUPPLY LINE, b - MINIMUM 72 INCHES OF AGENT LINE FROM TANK TO FIRST NOZZLE. - IF APPLICABLE, PRE -PIPED CHARBR❑ILER DROPS ARE SHIPPED LOOSE, - FACTORY PIPING EXTENDS A MAXIMUM OF 6" ABOVE THE TOP OF THE HOOD. - APPLIANCE DIMENSIONS LISTED REPRESENT THE CO❑KING SURFACE SIZE, NOT THE OVERALL APPLIANCE SIZE. - THIS FIRE SYSTEM COMPLIES WITH U.L. 300 REQUIREMENTS I�I JOB FLAMERS - SEMINO E TOWN CENTER I i LOCATION SANFORD, FL AN®■gin ,era®► ®' DA TE 2 / 15 / 9 5 JOB ®AUNIM � "" DWG. # 509FST2S DWX. BY EJF I V --, REV. 5/9/95 SCALE NOT TO SCALE i i; 1 f i