Loading...
HomeMy WebLinkAbout1190 W Lake Mary Blvd 95-1294Component Performance Method for Commercial Buildings I ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs FLAICOM-94 Version 2.1A PROJECT NAME Q#7085 SIN8830-32 ADDRESS: OWNER: G.E. CAPITAL MODULAR SPACE_ AGENT: Form 40OB-94 PERMITTING OFFICE: Sanford CLIMATE ZONE: 5 PERMIT NO: _ JURISDICTION NO: 691500 BUILDING TYPE: _Business (Office) CONSTRUCTION CONDITION: New construction DESIGN COMPLETION: _Finished Building CONDITIONED FLOOR AREA: _3280.01 MAX. TONNAGE OF EQUIPMENT PER SYSTEM: 4 COMPLIANCE CALCULATION: NUMBER OF ZONES: 1 METHOD B DESIGN CRITERIA RESULT ENVELOPE PERFORMANCE 47.79 80.87 PASSES OTHER ENVELOPE REQUIREMENTS PASSES LIGHTING INTERIOR LIGHTING 4104.00 7089.50 G 2$ PASSES EXTERIOR LIGHTING 720.00 1050.0019/(,'fPASSES LIGHTING CONTROL REQUIREMENTS 3,- cr plqn O' K 0PASSES HVAC EQUIPMENT ` d y ETN COOLING EQUIPMENT APp 1. SEER 10.00 ) a PASSES HEATING EQUIPMENT d v"" U 1. Et 1.00fil N/A AIR DISTRIBUTION SYSTEM INSULATION LEVEL yessT3s 1. Ventilated 6.00 F'6.00 PASSES WATER HEATING EQUIPMENT PIPING INSULATION REQUIREMENTS COMPLIANCE CERTIFICATION I hereby certify that,the plans and specifications covered by this calcu- lation are in complianc with the Florida Energ Ef cie ode. PREPARED BY: DATE: 2 I hereby certify that this building is in compliance with the Florida Energy Efficiency Code. OWNER/ AGENT: DATE : . Review of the plans and specifica- tions covered by this calculation indicates compliance with the Florida Energy Efficiency Code. Before construction.is completed, this building will be inspected for compliance in accordance with Section 553.908, Florida Statutes. BUILDING OFFICIAL: DATE: I hereby certify(*) that the system design is in compliance with the Florida Energy Efficiency Code. SYSTEM DESIGNER REGISTRATION/STATE ARCHI ECT MECHANICAL: PLUMBING ELECTRICAL : LIGHTING Signature is required where Florida law requires design to be performed Eby registered design professionals.. Typed names and registration numbers may be used where all relevant information is contained on signed/sealed plans. BUILDING INFORMATION COMPLIANCE CHECK 401.------GLAZING--ZONE 1------------------------------------------------ v- Elevation Type U SC VLT Shading Area(Sgft) West Commercial 1.13 7 1.0 None 43 East Commercial 1.13 7 1.0 None 43 East Commercial 1.13 7 1.0 None 5 West Commercial 1.13 7 1.0 None 5 Total Glass Area in Zone 1 = 96 Total Glass Area = 96 402.------WALLS--ZONE 1 ------------------------------------------------ Elevation Type U Added R Gross(Sgft) East Frame Wall + 3" InS. 0.081 0.0 720 West Frame Wall + 3" InS. 0.081 0.0 720 North Frame Wall + 3" InS. 0.081 0.0 369 South Frame Wall + 3" InS. 0.081 0.0 369 Total Wall Area in Zone 1 = 2178 Total Gross Wall Area = 2178! 403.------DOORS--ZONE 1 ------------------------------------------------ Elevation Type U Area(Sgft) East 1-314 Steel Door -Paper Honeycomb core 0.56 95 West 1-314 Steel Door -Paper Honeycomb core 0.56 95 South 1-314 Steel Door -Paper Honeycomb core 0.56 80 Total Door Area in Zone 1 = 270 Total Door Area = 270 404.------ROOFS--ZONE 1 ------------------------------------------------ Type 't Color U Added R Area(Sgft) STD. TRUSS Light .0526 0.0 3280 Total Roof Area in Zone 1 = 3280 Total Roof Area = 3280 405.------FLOORS-ZONE 1 ------------------------------------------------ Type R Area (Sgft) Floor over Unconditioned Space/Insulated 11 3280 Total Floor Area in Zone 1 = 3280 Total Floor Area = 3280 406.------INFILTRATION -------------------------------------------------- Infiltration Criteria in 406.I.ABC.1 have been met. ICHECKI/ 407.-=----COOLING SYSTEMS ------------------------- No Efficiency IPLV Tons 1. Single Package 3 10.0 0.0 4.00 408.------HEATING SYSTEMS ----------------------------------------------- Type No Efficiency BTU/hr 1. Electric Resistance 3 1.0 35000 409.------VENTILATION --------------------------------------------------- CHECK Ventilation Criteria in 409.1.ABC.1 have been met. 410.-----AIR DISTRIBUTION SYSTEM ---------------------------------------- AHU Type Duct Location R-value Ventilated 611'. packaged Constant Volume 411.-----PUMPS AND PIPING -ZONE 1 --------------------------------------- Type R-value/in Diameter Thickness 1. Non -Circulating w/o Heat 3.63 0.75 1.0 412.--- -WATER HEATING SYSTEMS -ZONE 1---------------------------------- Type Efficiency StandbyLoss InputRate Gallons 413.-----ELECTRICAL POWER DISTRIBUTION---------------------------------- CHECK Metering criteria in 413.1.ABC.1 have been met. Transformer criteria in 413.I.ABC.2 have been met. WA 414.-----MOTORS --------------------------------------------------- Motor efficiencies in 414.1.ABC.1 have been met. t-- 415.-----LIGHTING SYSTEMS -ZONE 1------------------------------------- - Space Type No Control Type 1 No Control Type 2 No Watts Area(Sgft) Reading, T 1 On/Off 2 None 00 350 285 Reading, T 1 On/Off 2 None 00 350 265 Reading, T 1 On/Off 2 None 00 350 278 Reading, T 1 On/Off 2 None 00 350 278 Reading, T 1 On/Off 2, None 00 350 278 Reading, T 1 On/Off 2 None 00 350 278 Reading, T 1 On/Off 2 None 00 350 278 Reading, T 1 On/Off 2 None 00 350 278 Reading, T 1 On/Off 2 None 00 350 278 Reading, T 1 On/Off 2 None 00 350 278 Toilet and 1- On/Off 2 None 00 180 149 Toilet and 1 On/Off 2 None 00 120 77 Toilet and 1 On/Off 2 None 00 120 77 Toilet and 1 On/Off 2 None 00 180 155 Total Watts for Zone 1 4104 Total Area for Zone 1 3251 Total Watts 4104 Total Area 325I CHECK Lighting criteria in 415.1.ABC have been met. 16. HVAC load sizing has been performed. (407.1.ABC.1) 17. Duct sizing and design have been performed. (410.1.ABC.1.2) 18. Testing and balancing will be performed. (410.I.ABC.4) 19. Operation/maintenance manual will be provided to owner.(102.1) i v 1 61A) CG Gi min c C! ass ronrn fold 4 oh V/, LaLe, IA '31 vd /3 -1 q, 5 I a 9 Lf