HomeMy WebLinkAbout2300 W Airport Blvd 99-2810 Fire inspectionCTY"Y OF SANFORD FIRE DEPARTMENT 1303 South French Avenue Sanford, Florida 32771 407) 302-1091 (407) 302-1097 FAX Plans Review Sheet Date: June 1,1999 Business Address: 2300 W. Airport Blv Occ. Chap. 26,28 Business Name: Hertz Ph. Contractor: CES Ph.645-5582 Reviewed [ ] Reviewed with comment F[ ] Rejected [ ] Reviewed by: Bart Wright, Fire Protection Inspector Comment: 1.1 Application — New building 6400 sq. ft. 1.2 Mixed - business/industrial 1.3 Special Definitions- None noted 1.5 Classification of Hazard of Contents - Ordinary 1.6 Minimum Construction — N/R; type W up 1.7 Occupant Load — 1/100 business; limited to necessary number of persons for use - industrial 2. of Egress Components —Access to mezzanine appears to be omitted; door #8 door swing obstructs means of egress (does it swing 180 de2rees?):--- 2.3 Capacity of Egress — O.K. 2.4 Number of Exits — O.K 2.5 Arrangement of Egress — O.K. 2.6 Travel Distance — O.K. 2.7 Discharge from Exits — O.K. 2.8 Illumination of Means of Egress - O.K.; will field verify 2.9 Emergency Lighting - O.K.; will field verify 2.10 Marking of Means of Egress - O.K.; will field verify 2.11 Special Features — N/N 3.1 Protection of Vertical Openings — N/N 3.2 Pro on from Hazards - 2 hour separation noted between business and industnall 3.3 Interior Finish — Class "C" minimum 3.4 Detection, alarm and Communications Systems — N/R 3.5 Extinguishing Requirements — as noted on plans 3.6 Corridors — N/N 4 Special Provisions — N/N 5 Building Services — 5.1 Utilities 5.2 HVAC — Per NFPA 90-A 5.3 Elevators, Escalators, Conveyors (4A-47) 5.4 Rubbish Chutes, Incinerators, and Laundry Chutes Sanford City Code - Chapter 9 Fire Sprinklers: Not Required Monitoring: N/A Other: NFPA 1 3-5.1 Fire Lanes — Required if any portion of bldg. is greater than 150' from roadway 3-6.1 Key Box - Required; will field locate and verify 3-7.1 Bldg. Address Number Posted and Legible - Required; will field locate and verify A CITY OF SANFORD INSPECTIONS DIVISION COMMERCIAL REVIEW COMMENTS NEW CONSTRUCTION PROJECT:A0 0 f,c/i.1 ,ovs pe Y DATE: JwJe, qqp ADDRESS: 23oo W. /,. I j J. SANFORD, FL CONTRACTOR: ekS 0aX*AXeA j IW: LIC# C IBC -,46 7,:2 jv ADDRESS: PHONE #y 3a-7 sq REVIEW COMMENTS: 1. Finish floor elevation 'shall be 16 inches above center line of established street or a min. of 8' above grade when property has no paved street. City Sections 6-7. f-, 2. Strip footers shall be continuous with 245 rebars for 1-story buildings, 2-story buildings shallhave345rebarsinfooters, and #5 dowel at each corner. Size of footers shall be 8" x 16" min. for a 1-story and 10" x 20" for a 2 story. 3• Mono footer/slab combination shall be 20" deep and 16" wide with 45 degree angle into 4" slab. 2-story shall be 20" deep and 20" wide with 45 degree angle into 4" slab. Reinforcementshallbeasinstripfooteralllapsamin. of 25 inches. 4. Masonry construction shall have a min. of 145 rebar in lintel course or tie beams. Vertical down rods shall be #5 rebar with 24" bend tied to lintel rebar and min. of 25" lap at eachdowelandtied. 5. Means of egress shall comply to Chapter 10, 1997 S.B.C. 6. Means of egress and illuminations shall comply to section 1016.1, 1016.2, and 1016.3ExitSigns) 1997 S.B.C. 7. All corridors shall be a minimum of 44", Table 1004, 1997, S.B.C. 8• All restrooms shall comply to 1997, H.C.F.S. 553, Part 5. X 9 Interior finishes shall comply to Chapter 8, Table 803.3, 1997, S.B.C. 10. All electrical wiring service and futures shall comply to 1996 N.E.C. and Notice L amendments. 11. All plumbing shall comply to 1994, S.P.C. and 1997 F.S. 553, Part 5 FloridaAccessibilityCode 12. All mechanical equipment & duct systems shall comply to 1997, S.M.C. and 1997FloridaEnegryCode. 13. Firewalls or tenant separations shall comply to Sec. 413.3 & Table 704.1 & 704.1.4, 1997 S.B.C. All rated wall pentrations shall be sleeved and fire caulked. X 14. Stairs shall comply to Section 1006,1007,1007.1.2,1007.3,1007.4;1007.5,1007.5.3,1007.6, 1007.7,1007.8,1008.6, &1997 S.B.C. 15. Shall comply to 1994 N.F.P.A. -1. 1 16. Shall comply to Life Safety Code 101,1994. 17. Final grading inspection needs to be done after final grade but prior to final landscaping. Reviewed By: N177 owausr(c,l $IdS a300 Ai rPo-r + -,j?M d qq a gi D