Loading...
HomeMy WebLinkAbout121 Anthony Dr 95-304,95-491, 95-537 New SFHC6-- qC(� Q5-J3 -) ZONE (Sp- 1 DATE � ��� C4 41 CONTRACTOR Norw) I nan ADDRESS C O'n `�` ^�- PHONE # LOCATIOf OWNER ADDRESS PHONE # PLUMBING CONTRACTOR - `yl 1 02A 12 ADDRESS _ PHONE # ELECTRICAL CONTRACTOR !!E // t l ll ff L)eC 52 ADDRESS PHONE # MECHANICAL CONTRACTOR ADDRESS PHONE # MISCELLANEOUS CONTRACTOR i ADDRESS ARCHITECTURAL APPROVAL DATE: SUBDIVISION: q,�5-30(q PERMIT # JOB COST $ FEE $ STATE NO. G J,, r FEE $ (0 FEE $ 7� FEE $ LOT NO. ff, BLOCK: SECTION: SQUARE FEET: /&,33 MODEL: �r OCCUPANCY CLASS: / INSPECTIONS TYPE DATE OK REJECT BY FEE $-- ENERGY SECT. EPI: j E �:',:'. 1yy Fr ' i f', `- �' �.. h I� I� I` �• F h I ' t 7 S y r-- — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — -1 { F ' � I i { 21' -2' I I I (I I ; DEPRESS SLAB 3/4' 1 I UNDER GARAGE DOOR I i I 1{ 1' SLOPE I I � TYPICAL SECTION NOTES: O 4' CONC, SLAB W/ FIBERMESH o I I I D UNLESS OTHERWISE NOTED, PLAN DIMENSIONS ARE GIVEN ( OR 6x6 # 10 WIRE MESH OVER EL 0'-0' (ASSUMED)I i TO THE OUTSIDE OF THE STRUCTURAL PORTION OF THE I , I VAPOR BARRIER OVER CLEAN REFERENCE I I i COMPACTED POISONED SOIL I I I WALL. 1A CAST IN PLACE CONCRETE FOOTER, 16" WIDE, 8" HIGH, { G= +/- 12„ t 1 B CAST IN PLACE CONCRETE FOOTER, 20" WIDE, 10" HIGH, ` 1 G= +/- 44". I I { 1 C THICKENED SLAB FOOTER, BOTTOM 12" WIDE. SLAB & FOOT- I ER 8" THICK. 2A STEEL REINFORCING: (2) #5 REBAR: ALL REINFORCING CON-— TINUOUS THROUGH FOOTER.- 2B STEEL REINFORCING: (3) #5 REBAR; ALL REINFORCING CON- 1 _ _ TINUOUS THROUGH FOOTER. , {L. 1 #5 REBAR; ALL REINFORCING CON- { 'v�•� t1Z�.' 2C STEEL REINFORCING:O i I I dJ TINUOUS THROUGH FOOTER. { { STEPPED FOOTER - SEE DETAIL B STEPPED FOOTER - SEE DETAIL B _ _ 3 CONCRETE BLOCK WALLS, 8" WIDE. REINFORCED ( L I _ �r INDICATES 24'x24'x12` DEEP DOWNPOURS AT 6" O.C. MAX. OR WHERE SHOWN ON THE 1 I I CONIC. PAD W/(3) #5 REBAR EACH WAY (TYP.) PLANS. DOWNPOUR REINFORCING IS #5 REBAR UNLESS I OTHERWISE NOTED. BEND REBAR INTO FOOTER AND BOND BEAMS I2"MIN. �- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - J { I 4 STEM WALL BOND BEAM: CAST IN PLACE WITH SLAB; CHAIR BLOCK OPTIONAL AS FORMS; 8 x 8, REINFORCRED WITH (1) L— y #5 REBAR CONTINUOUS THROUGH. -02 7 EXTERIOR FACING: TO BE SELECTED. 41 8 CAST IN PLACE CONCRETE SLAB, 4" THICK. 9A SLAB REINFORCING: 6 x 6 WELDED WIRE FABRIC (WWF). WWF REINFORCING WILL BE DOUBLED BACK 36" AT ALL SLAB 441J8� PERIMETERS BELOW FRAME WALLS. 9B SLAB REINFORCING: FIBERGLASS FILAMENTS PER MFGR'S SPECIFICATIONS. 10 POLYETHYLENE BARRIER. 17 11 POISONED AND COMPACTED EARTH. 27 15 WOOD FRAME WALLS: 2 x 4 STUDS @ 16" MAX. 16" O.C. PRES- FOUNDATION PLAN SURE TREATED SILL PLATES AGAINST CONCRETE, DOUBLE g TOP PLATES; ALL BEARING WALLS #2 SOUTHERN PINE OR # 2 ::s PRoc- e . 16A INSULATION: R-11 6 16C INSULATION: R-30 17 WALL & ROOF SHEATHING 1/2" CDX PLYWOOD OR APPRO- VED EQUAL. NAILING IS 8d, 4" Q.C. AT ALL PANEL EDGES, 6" O.C. ELSEWHERE PROVIDE METAL "H" CLIPS BETWEEN CELNG HT, PANELS BETWEEN ALL ROOF TRUSSES -� 18 INTERIOR FINISH' SEE FINISH SCHEDULE 26 DOOR OR WINDOW: SEE PLANS & SPECIFICATIONS 29 31 27 ROOF SYSTEM. MANUFACTURED WOOD TRUSSES. TRUSS MFGR. WILL DESIGN AND CERTIFY THE SYSTEM TO COMPLY EL, 6' A F.F. WITH SBC SSTD 10-93, 100 MPH WIND ZONE, WITHIN THE F-EADER HT. PARAMETERS OF THE ROOF FRAMING PLAN AND THE TRUSS PROFILES PROVIDED. 26 I 28A SELF-SEALING FIBERGLASS SHINGLES ON 15 LB FELT. 29 ROOF PITCH: 6/12. OVERHANG: 2' TYP. TAIL CUTPLUMB. I 3 FASCIA: ALUMINUM. SOFFIT: VENTED ALUMINUM. I 31 LINTELS AND HEADERS. DOUBLE 2 x 12 WITH 1/2" PLYWOOD FLITCH PLATE OR MANUFACTURED BEAM; MIN. 31/2 x 11"1/41. LINTELS OR HEADERS MAY BE SPECIFICALLY DESIGNED; SEE — — — — — — — — — — — — — — — — — — — PLANS AND/OR BEAM SCHEDULES. STRUCTURAL NOTES: 1 CONCRETE TO BE 3000 PSI MIN. 2 STEEL REINFORCING BARS: GRADE 40, MIN. SPLICE LAP 25". 3 STEEL COVERAGE: FOOTINGS AND SLABS AGAINST EARTH (3) INCHES, TIE BEAMS (2) INCHES 4 CONCRETE MASONRY UNITS SHALL CONFORM WITH ASTM C-90 HOLLOW LOAD BEARING CONCRETE MASONRY UNITS, TYPE 1, GRADE N-1, NORMAL WEIGHT, 8 x 8 x 16 5 MORTAR SHALL CONFORM WITH ASTM C-91 FOR MASONRY CEMENT AND ASTM C-150 FOR PORTLAND CEMENT MORTAR SHALL BE TYPE M. 6 HORIZONTAL MASONRY JOINT REINFORCEMENT WHERE INDICATED SHALL BE #8 TRUSS TYPE AT, EVERY OTHER BLOCK COURSE. LAP SPLICES 6" MIN> 7 CONTRACTOR WILL VERIFY ADEQUATE SOIL CONDITIONS BEFORE COMMENCING WORK (2500 PSF MIN. BEARING CA- PACITY REQUIRED). 0 CONNECTOR SCHEDULE: 1 SILL PLATE ANCHORS: 1/2" DIA. x 8" J-BOLT, MIN. EMBEDMENT 6", HOOK UNDER REBAR, 21" MAX. O.C.. SHEAR WALL ANCHORS MAY BE SUBSTITUTED WHERE LOCATED ON THE PLAN, I.E.: SIMPSON HD5A, 3/4"x 8 J-BOLT INTO CONCRETE (HOOK UNDER REBAR); ,(2) 3/4" DIA. BOLTS THROUGH STUDS WITH 2" DIA WASHERS OPPOSITE CONNECTOR) 2 PLATES TO STUDS: SIMPSON SP1, 6-10d TO STUD, 4-!Od TO SILL PLATE: SIMPSON SP2, 6-1Od TO STUD, 6-1 Od TO TOP PLATES 3 TOP PLATES TO TRUSSES: SIMPSON MTS16, 14-10d TOTAL. 4 COLUMN BASE TO CONCRETE: SIMPSON PBS44, 14-16d TO COLUMN 5 COLUMN TO HEADER SIMPSON ACE4, 8-16d TO HEADER, 6- 16d TO COLUMN ALL- 10.1 EA, H EAWC, STuP4i . sl M(2el'3ht L.hTI b ; t d -►�d 16' TYPICAL WALL SECTION 3/4' = 1' -0' e n u ELEVATION - STEPPED FOOTER 3/4' = P-0' O 0 O u C FOOTER SECTION 3/4'=1'-0' j 1C �._ X. . 2 12't D FOOTER SECTION 3/4'=1'-0' J L SMITH & ASSOCIATES PROFESSIONAL ENGINEERS 1299 "' FAIRBANKS AVE., STE. B. WINTER PARK. FL 32789 ORLANDO (407) 740-7111 TAVARES (904) 343-7711 / (� l t�� DRAWN CHECKED DATE THIS DRAWING AND ITS REPRODUCTIONS ARE THE PROPERTY OF J L SMITH d ASSOCIATES AND MAY NOT BE REPRODUCED WITHOUT THE WRITTEN CONSENT OF J L SMITH d ASSOCIATES O 9 TRUSS PROFILE "A" 1/4'slt-0' 6� I2 1-0' TRUSS PROFILE 11B" 1/4'a1'-0' TRUSS PROFILE 11 C11 1/4'-l'-0' 20t- Opt ROOF FRAMING -------,, DOUBLE TOP PLATE 21 _01 -�- HEADER TYP, CONNECTORS REQUIRED FULL LENGTH WALL STUDS A A HEADER STUDS II II II II 11 I I I I I NO CONNECTOR REQUIRED — I I II II II II II II A II II 11 II II II A II II II II II II mill TYR FRAMING & CONNECTIONS FOR OPENINGS 1/2'-P-0' Co I f?'v r R -5 E E Go N N49-G1'o r2' Nc)lm 'r . Uplift connection requirement at points "A" - top and bottom of header studs, sec Covioe- - -7, Uplift connection is required at each end of header and at bot of header studs in addition to connectors at wall studs. ROOF FRAMING PLAN na'-r-o• tom Maximum Header Span (ft,) 3' 6' 9' 12' 15' 18, Number of Header Studs Supporting End of Header 11 1 2 2 2 2 Unsupported Stud Number of Header Studs Supporting Wall Height Spacing End of Header 10, 12' 2 2 3 3 3 3 or less 16' 2 2 3 3 3 3 24' 1 2 2 2 2 2 greater 12' 2 2 3 4 5 5 than 10' 16' 2 2 3 3 4 4 24' 1 2 2 2 3 3 1. The header stud shall not be recoured if the header is supported by a suitable framing anchor, MINIMUM WALL AND HEADER STUD REQUIREMENTS 0 THE STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE WITH, AND MEETS THE REQUIREMENTS OF SECTION 1205 STANDARD BUILDING CODE FOR ONE HUNDRED (100) MILE PER HOUR WIND ZONE. CERTIFICATION BY ENGINEER APPLIES TO ABOVE STATEMENT ONLY. J L SMITH & ASSOCIATES PROFESSIONAL ENGINEERS 1299 W. FAIRBANKS AVE. STE B. WINTER PARK. FL 32789 ORLANDO (4()7) 740-7111 TAVARES (904) 343-7711 �- DRAWN CHECKED DATE THIS DRAWING AND ITS REPRODUCTIONS ARE THE PROPERTY OF J L SMITH 6 ASSOCIATES AND MAY NOT BE REPRODUCED WITHOUT THE WRITTEN CONSENT Of J L SMITH & ASSOCIATES 0 i r p w m _ O O W F- n O o - V / >LLJ ' -.. - - Z oco ' OUP � .r a-Wv) -ZJ j o a 1 Z O <0 wW0 U Z > t= O Z W Q O O U UW(r NWIrO W J= ccna V)0 �COWO f, fit->Q' a E—VQ� ��C-W ' LLI E- o a: o cr , ozi =o 4 .. G -. GENERAL NOTES 1. DO NOT SCALE DRAWINGS, DIMENSIONS SHOWN SHALL: BE USED IN PREFERENCE TO MEASUREMENTS BY SCALE 2. CONTRACTOR SHALL VERIFY ALL. DIMENSIONS AND EXISTING CONDITIONS AT SITE BEFORE PROCEEDING WITH ANY WORK '3. NOTES INDICATING TYPICAL -CONDITIONS SHALL APPLY TO ALL LIKE AREAS UNLESS NOTED 'OTHERWISE. r i_0 4" CONC. SLAB W/ FIBERMESH OR 6X6 #10 WIRE MESH OVER VAPOR BARRIER OVER CLEAN COMPACTED POISONED SOIL 44' —8" FOUNDATION PLAN SCALE 1/4-=1 ELECTRICAL PLAN DEPRESS F R GARAGE DOC R 11 SLOPE -INDICATES (1) 24" X24" X 12" DEEP CONC PAD W/ (3) 4#5 RFRAR