Loading...
HomeMy WebLinkAbout4100 Paola Rd Load calcsFORM 800A-86 A i FLORIDA MODEL ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION SECTION 8 -- SIMPLIFIED ANNUAL ENERGY METHOD ADMINISTZR=D nY THE DEPARTMENT OF COMMUNITY AFFAIRS C STATISTICS NON - RESIDENTIAL BUILDINGS PROJECT NAME Yi Shqreji PERMITTING OFFICE O Q 6-L l. ICI ADDRESS: 10 )0"A d, JURISDICTION N0. C. -I c,p CITY, ZIP CODE 5 I L 737-7-7/ PERMIT NO.: BUILDER ZONE: CJ O W N E R 1 C5'r IC.G QMTi T C.l[i/2L14 b Kit .Zke I BUILDING CLASSIFICATION(S) zw BUILDING VALUE, S SYSTEMS AIR CONDITIONING UNIT NUMBER{ TYPEI EERSEER COP TONS U = UNITARY. 0 = CENTRIFUGAL P - POSITIVE DISPLACEMENT ENVELOPE Net Area U SWALLN0. 1 Coo NO. 2 ROOF I 6,4 caS RAISED FLR / INT WALL GLASS TOTAL CONED-*cF A AREA= 4gap S.F. LIGHTING TOTAL KW = 2,4. Compliance with Section 8 was demonstrated by a Prescrip- tive Measures methodology or by Dual Calculation. 807.2 Supermarkets 809.2 Basic Features 807.3 Restaurants 809.3 Dual Calculation 807.4 Kitchens Budget — HEATING UNIT NUMBER TYPE COP BTUH Q G 1 2_ I•i P Z, t7oo E - ELECTRICAL RESISTANCE HP - HEAT PUMP G - GAS 0 - OIL COMPLIANCE - SECTION ® BUDGET - -14,o BUILDING MBTU/SF 2.4- SECTION 4 BUILDING MBTU/SF CALCULATION METHOD In accordance with Section 553 907 FS.. I hereby certify that the plans and specifications covered by this calculation are in compliance with Me Florida Energy Code , OWNER AGENT Moe I DATE Review of the plans and specifications covered by Iris caicu!auon indt- cale compliance with the Florida Energy Code Befo,e construction 15 completed, this building will De rnspecled for compl,ance n accordance with Section 553 908 F S BUILDING OFFICIAL 4/ /y` DATE —// 7 — --- 1 F 0 R M 8 0 0 A 86 FLORIDA MODEL ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION SECTION 8 SIMPLIFIED ANNUAL. ENERGY METHOD ABRINISTERED BY THE DEPARTMENT OF COMMUNITIY. AFFAIRS_ BUILDING TYPE CHURCHES ( ZW 1 CLIMATE ZONE : 5 ENERGY CONSUMING WINTER SPRING FALL SUMMER ELEMENTS Ue x AREA MTR = MBTU Ue x AREAx MTR = MBTU Ue x AREAx MTR-= MBTU WALLS Uw x Aw WWM = Uw x Aw xWSFM =, Uw x Aw xWSM. A5tiT SZaac::_ w/' t''g' 0.05:2604 9.5.:-1236.9 0.05:2604 6 :781.2 0.05:2604 11.4 1484.28 ROOF Ur x Ar RWM _ Ur x Ar xRSFM = Ur x Ar xRSM = w/co ' •C 0.05: 6400 2 ; : -640 .0. 05: 6400 36..9, : 11808 0.05:6400 44.5 14240 RAISED FLOOR Uw x Aw WWM = Uw x Aw xWSFM = Uw x Aw xWSM = SOLAR OR Sc x Ag SWM = Sc x Ag xSSFM Sc 'x Ag xSSM D----------------------------------------------------------------------------- 0=0.5L=9G=7 NEO.95:64 13.96:848.77 0.95:64 42.26:2569.41 0.95:64 49.1 :2985:28 0=0.5L=9G=7 SEO.95:64 51.26:3116.61 0.95:64 81.22:4938.18 0.95:64. 58.46:3554.37 0=0.5L=7G=6 SWO.95:24 54.53:1243.28 0.95:24 90.52:2063.66 0.95:24 55.18:1258.1: 0=0.5L=7G=6 NWO.95:24 14,21:323.99 0.95:24 47.95:1093.26 0.95:24 53.81:1226.87 GLASS CONDCTN. Ug x Ag CWM = Ug x Ag xCSFM = Ug x Ag xCSM = E i u L-r> 1.1 :176 10.3:-1994.08 1.07:176 2.5 :470.8 1.04:176: 11.5 2104.96 OUTSIDE AIR CFM VWM = CFM xVSFM = CFM xVSM = F---------------------------------------------------- 15 ,T x 400 Cfm 6000 10.4:-62400 6000 8 :48000'' 6000 62.2 373200 PEOPLE HEAT Ar PWM = Ar xPSFM -- Ar xPSM = G------------------------------------------------------ Af= 4900 4900 15.11 :73990 4900 25.2 :123480_ 49210 20.2 98980 LIGHTING HT WATTS LWM = WATTS xLSFM = WATTS xLSM = H------------------------------------------------------------------------ F'1=88 Ic=2340 2428 2.08 :5050 2428 2.21 :5366 2428 2.36 '5730 HVAC MTR HEAT. BHP' MWM = BHP xMSFM = BHP xMSM = I-------------------------------------------------------- Not incl./COP 2 0 :n/a 2 0 :n/a 2 0 n/a PAGE ( 2 L START UP HEAT S. U H " 1.4 2469.6 M WINTER PTS SP/FL PTS SUMMER PTS 18301.67 196309.46 495739.24 N C S M 0.38 C S .M 0.38 C S M 0.38 P, 6954.63 74597.59 188380.91, ENERGY SUMMARY HEATING: 2469.6 COOLING: 269933.13 TOTALS 272402.73 LIGHTING L R E xWATTS MBTU RAW ENERGY 8.16 2428 19812.48 19812.48 WATER H W xA f HWMBTU HEATING 0 4900. 0 0 Q----------------------------------.---- HVAC M R E xH /. P MRMBTU MOTOR AHUS-VAV 6680 2 13360 13360 ENERGY R:TOTAL MBTU 305575.21 R:TOTAL MBTU S:FLOOR AREA T:DESIGN ENERGY U:ALLOWABLE BUDGET (6--1) 305575.21 7------------------------------------------------------------- 4900 62.36 74 4 , r....4 ". -- - ( i - i°.--... i , cm..re-- I. 1. r >j-I 2 f.;:.. . F I r m€ i e..:.3 Z 4 m. ,..mi La®..,1 i 4 ®..,tea, ;:.a L._.-...:a a m e"° C"= a ., ,: ,-. _s c...r'z` Z. '.'...": "9 E.w.. w.. 9 4 t _ T"'" ._.. . "' P 1 G C'.3 b'f "y ".'^ w.P ": c,...! r i"- .'".-... - .ram--....a C Y^` ARCHITECTS PLNNNERS . November 10, 1987 City of Sanford Mr. Gary Winn Chief Building Official 300 N. Park Ave. Sanford, Florida Re: Plans For Building Permit Dear Mr. Winn: Please allow this letter and the attached sketches to become part of the permit package as submitted to you by Pastor Maslin. Exhibit "A"'is a proposed entrance riser diagram. Exhibit "B" is an electrical load calculation. Exhibit "C" is our recommendation from our soils engineer as to the method of capping the existing abandoned water well. Please feel free to contact me if you require additional clarification on the aforementioned. Thank you for your time and cooperation in this matter. Sincerely, H.D.S. CONS S, INC. rI J es E. Zirk 1 sident JEZ:jcb Enclosures 750 MIAMI SPRINGS DRIVE, LONGWOOD, FLORIDA 32779 (305) 862-5444 / 869-5444 E3- 2-00 A I --MW- -O-RVA 0- F- &---- , - - - ELECTRICAL LOAD Lighting & Recept. HVAC Load Misc. EXHIBIT "B" 4900 S/F x 1 Watt/SF = 4900/240 = 21 A 57KW/240 x 40% = 95 A 1000 watts/240 Total Load EXHIBIT "C" Fill existing metal casing (abandoned well) with sand and gravel to a level two feet from the top of casing. Fill remaining two feet of casing with concrete and cap. 4 A 120 AMPS