HomeMy WebLinkAbout2439 Airport Blvd 20909 Fee Worksheet Seminole National Bankwater Meter Size (3/4",
1", 2", etc.):
REMARKS:
2) NON-RESIDENTIAL
Type of Units (commercial,
industrial, etc.):
Total Number of Buildings:
Number of Fixture Units
each building):
Type of Utility Connection
individual connections
or central water meter &
common sewer tap):
Water Meter Size (3/4",
1", V , etc.):
REMARKS:
CONNECTION FEE CALCULATION:
cok d- SE "CA 7,9,
b9Z rC4 14,64ER c a"At EX
r
r--
Sw6,e 6,fe wlH AeE
rOEv,EI . SEE.
d-
EFFECTIVE: November 12, 1085
UTILITY DEVELOPMENT FEES
1) Residential
Fees per dwelling unit:
Water Growth Fee:
Sewer Growth F,ee:
W a t e r T a p ( 3/ 4 )( See table for larger water)
Sewer Tap:
TOTAL
2) Non -Residential
A. Fees per structure bared on number of fixtures
Water Growth Fee: (sve fixture schedule)
Sewer Growth Fee: (ace fixture schedule)
Water Tap (3/4): (see table for larger meter)
Sewer Tap:
3)
TOTAL
700.00
1,800.00.
130.00
260.00
2,890.00
700.00
1,800.00
130.00
260.00
2 , 890 .00
B. The growth portion (water & sewer) of the connection
fee shall be computed by the following schedule:
FIXTURE SCHEDULE
of Fixture Units GrowirFee GrowfirFee Total
1 - 20 $700. $1,800.. $2,500.
21 - 40 $1:400. $3,600. $5,000.
41 - 60 $2,100. $5,400. $7,500.
61 - 80 $2,800. $7,200.- $10,000.
Over 80 - To be computed by adding $2,500. for each 20
fixtures or fraction thereof.
r
Any development requiring a water muter larger than 3/411, shall pay
the water tap portion of the connection fee as follows:
WATER METER SIZES VESS
3/4" $ 130.
1 " 210.
11 400.
2 " 500.
3 " 2,990. or they install
4 " 4,400. or they install
6 " 7,520. or they install
Any water or sewer tap work `that requires any street cut or tunneling
of the pavement shall pay au additional $250.00 for each such tap.
Type of Fixture or Group of Fixtures Fixture Unit Value
Automatic clothes washer (2" standpipe) 3
Bathroom group consisting of a water closet, lavatazy &
bathtub or shower stall: Tank water closet 6
Plush valve water closet 8
Bathtub (with or without overhead shower) 2
Bidet 3
Combination sink -and -tray w/food waste grinder 4
Combination sink -and -tray w/one i}" trap 3
Combination sink -and -tray w/separate i}" trap 3
Dental unit or cuspidor 1
Dental lavatory 1
Drinking fountain i X/ X2.
Dishwasher, domestic 2
Floor drains w/2" waste 3 k2 ;- 6
Kitchen sink, domestic w/one 1}" trap 2 k/_=
Kitchen sink, w/food waste grinder 3
Kitchen sink,w/food waste grinder &dishwasher li"-trap 5
Kitchen: sink, domestic w/dishwasher li" trap 4
4
Lavatory w/11" waste 1
2w/1 } 11--,waste
Laundry tray (1 or 2 compartments) 2
Shower stall, domestic 2
Showers (group) per.head 3
Sinks: Surgeons _ 3
Flushing rim (.with valve) 8
Service (trap,standard) 3
Service (P trap) :. 2k ': 2
Pot, scullery, etc. 4
Urinal, pedestal, syphon jet blowout 8
Urinal, wal lip 4
z yUrinal, stall, washout 4x)
Urinal trough (each 6' section) ;, 2
Wash sink (circular or multiple) each set of faucets 2
Water closet, private (tank operation) 4 k3 ? 2
Water closet, public (valve operation) 8
Fixtures not listed above: Trap size 11" or less 1
Trap size l;" 2
Trap size 2" 3
Trap size 21" 4
Trap size 3" 5
Trap size 4" 6
Reference: Standard Plumbing code, Table 1304.1>page 13-4 and
Table 1304.2 page 13-5. f V• 3 0 2