Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
3701 S Sanford Ave 20427 Fire record
FIRE PREVENTION DIVISION ef, BUILDING RECORD S NUMBER: TION: DATE: 3 - - E-5 B U it'LLA: i 27; 11 i CCUPANCY: S TYPE OF CONSTRUCTION: Fire Resistance - Type L . Type II Heavy Timber Non -Combustible Ordinary Wo=Frame Other:. - Remarks: SIZE: Total Area: S 7 % Sq. Ft. Number of Floors: Area Per Floor:- Sq. Ft. Basement: Partial'-- Full Size: Sq. Ft. Remarks: EXTERNAL WATER SUPPLY REQUIREbYENTS: G.P.Al. % 5 O No. of Hydrants Required: Public Hydrants: Locations; Private Hydrants: Yes No No. Requtired: i Locations: FIRE DEPT. ACCESS AND EXPOSURES: A.. Vehicle ( Tower or Pumper NORTH SOU TH EAST WEST Remarks: s B. Ground Ladders: NORTH SOUTH EAST WEST C.-'Exposures: i NORTH Ft. SOUTH Ft. EAST Ft. WEST Ft. t 5. MEANS OF EGRESS FACILITIES: Floor Occupant Load: 5 Area: I Types of Exits: No. Width Units Capacity Class A. Doors: B. Interior Stairs: C. Smoke Towers: D. Outside Stairs: E. Horizontal: F. Ramps: G. Others: TOTAL CAPACITY PROVIDED Required Provide Field Verified Number of Exits: Yes No Minimum Corridor Width: Arrangement: Max..Travel Distance: Max. Dead-end Limit: Exit Discharge: Door Closer: Type Locks: Egress.Illumination: Emergency Lighting: Rescue Windows: Exit Marking: i Smoke Proof Towers: 0 i Stair Pressurization: Remarks: Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes Yes Yes Yes Yes Yes Yes Yes No No No No No No No No Yes No Yes No Yes No Yes No Yes No Yes No b Yes No Yes No Yes No Yes No Yes No Yes No Yes No 6. ,VERTICAL FIRE RATED ASSEAIBLY SEPARATIONS: REQUIRED PROVIDED FIELD VERIFIEDYesNoYesNoYesNoBy. Exit Stairs: Basements: Floors: I Remarks: i 7. INTERIOR FINISHES: Class A Class B Class C FIELD VERIFIED Exits: Yes No gy, Corridors: Ceilings: Walls: Floors: Remarks: 8. FIRE DETECTION/ALARAI/CONIhNNICATION SYSTEMS:' REQUIRED PROVIDED FIELD VERIFIEDYesNoYesNoYesNoBy, Interior Fire Alarm: Voice Communication: Fire. Fighters: Remote to Fire Dept: Annunciation: Unit Smoke Detector: Remarks: 3 - FIRE EXTINGUISHING/PROTECTION SYSTEMS: REQUIRED PROVIDED FIELD VERIFIED Yes No Yes. No Yes No By. Date Standpipes: Sprinklers: Special Fixed: I Fire Extinguishers: i i Fire Pump: Remarks: 10. HORIZONTAL FIRE RATED ASSEMBLY SEPARATIONS: REQUIRID PROVIDED FIELD VERIFIED Yes No Yes No Yes No Rv_ nn+o Occupancy: Tenant: Bldg. Area: Hazardous Area: Egress Corridors: Fire Control Center: Attic/Concealed: Remarks: 1. SMOKE CONTROL SYSTEMS: REQUIRID PROVIDED FIELD VERIFIED Yes No Yes No Yes No By. Date Pressurization: Exhaust: Passive (AHU-Cut-) off) Elevator Shaft: Smoke Sections: i Sky Lights/Vents i Remarks: 0 L2. ELECTRICAL SYSTEMS: REQUIRED PROVIDED FIELD VERIFIED Yes No Yes No Yes No By. Date Shunt -Trip: Stand-by Generator: Special Hazard i Areas: Remarks: m AIR CONDITIONING SYSTEMS: REQUIRED PROVIDED FIELD VERIFIID Yes No Yes No Yes No By. Date Supply Ducts: Return Ducts: Fire Dampers: Smoke Dampers: AHU Controls: Remarks: 4. EXHAUST SYSTEMS: REQUIRED PROVIDED FIELD VERIFIED Yes No Yes No Yes No By. Date Cooking Equip. Dust Collection: Flammable Vapors: Remarks: 5. ELEVATORS: NUMBER: REQUIRED PROVIDED FIELD VERIFIED Yes No Yes No Yes No By. Date Lobby Smoke Dectors Shaft Pressurization Fire Service Control 5 -- REQUIRID Yes No PROVIDED FIELD VERIFIEDYesNoYesNoBY. DateEmergencyPowered: Shaft Exhaust Dumb -waiters: Vertical Conveyers: Remarks: 16. HEATING: Yes No Remarks Electric: Fireplace: Hot Air: Hot Water/Steam: Gas: LP: Oil: Portable: Other: 7. HAZARDOUS CONTENTS/OPERATIONS: PERMIT APPLICATION PERMITREQUIRIDSENTISSUED Yes No Yes No Yes. No Yes No Auto Tire Rebuild- ing Plants:6.02 Wrecking Yard and Waste:7.02 — Bowling Est.:8.02 Cellulose Nitrate Motion Picture Film: 9.02 A&B Cellulose Nitrate E Plastics: 10.02 A&B Combustible Fibers: 12.03 c 6— 1 PERMIT REQUIRED Yes No Yes No . Hazardous Chemicals: 22.02 Unstable Chemicals: 24.06 Liquified Petrolem: 25.02 -A&B Lumber Yards and Woodworking Plants: 26.01 Magnesium: 27.02 Oven Industrial Baking&Drying: 2 9.02 -A&B Places of Assembly: 30.101 Open Burning and Incinerators: 32.101-A&B&C Flammable and Combustible materials: 32.203 -A&B&C Matches: 32.206 Tents and Air Supported Structures: 33.01 Mechanical Refri- geration: 34.01 Organic Coats Manufacture: 36.03 High Piled Combust- ible Stock: 37.03 Motion Picture Projection: 38.02 Cryogenic Funds: 39.103 Airports,Ileliports, Helistops: 40102 Ak)PLICATION SENT Yes No PERMIT i ISSUED Yes No CITY OF SANFORO FIRE DEPARTMENT 9 1 303 SOUTH FRENCH AVENUE SANFORO. FL 32771 J. T. "Tom" Hickson Fire Chief Business: (305) 322-4952 Emergency: (305) 322-5332 March 12, 1985 Cardinal Industries 3701 S. Sanford Ave. Sanford, FL 32771 Gentlemen: Re: Office Complex 10 Fire flow required: 1750 GPM from any combination of hydrants within 500'. 2. Fire extinguishers ao.be installed in accordance with NFPA 10, 1982 edition. Sincerely yours, Fire Prevent MCH/ch I. STATE OF FLORIDA 'Department OE 3 CoIPe ional 7 C I tt IC.I3-1yS.T.RUCTI©N., INDUSTRY LIC.iVSI'lb RD I I BATCH NO. DATE: FILE NO. a2/09/84 Cf3 CO27112 0923 THECERTIFIED BUILDING CONTRACTOR NAMED BELOW IS CERTIFIED I UNDER THE PROVISIONS OF CHAPTER 489 FOR THE YEAR EXPIRING JUTE 3C3' 1985 MORGAN. CLI FTON D CARDINAL! INDUSTRIES OF FL INC 3701 S SANFORD AVENUE SANFORD FL 32771 SECRETARYOF SiONILL RE uTION cov INor+ i DISPLAY IN A CONSPICUOUS PLACE r+cunoN Q. ha( Zr d vs f es