SANFORD FIRE DEPARTMENT
FIRE PREVENTION DIVISION
300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772
(407 302-2520 / FAX (407) 302-2526
Plans Review Sheet
Date: June 17, 2004 Business Address: 2201 W.P. Ball Blvd.
Occ. Ch. 36, Mercantile Class `B'
Business Name: Petco Store
Architect: Phillips Partnership
Ph. (770) 394-1616
FAX (770)394-1314
P H (770) 394-1616
Fax. (770) 394-1314
Contractor: T.B.A. (out to bid at time of submittal)
Ph. ( )
Reviewed by: Timothy Robles, Fire Protection Inspector/Plans Examinerz--X-��
Comment: Plans reviewed as Mercantile Occupancy. FD reserves right to require
applicable code requirements if occupancy use changes. Sprinkler plans to be submitted for
review, permitting, and inspections. Sealed letter from Engineer of Record stating design
criteria for sprinkler system needs to be submitted with construction plans.
Separate permit required for Fire Alarm.
1.1 Fire Alarm required for monitoring of sprinkler system
1.2Application — New Building (15,359 s. q. ft.)
1.3 Mixed — N/A, all restaurants under 50 occupancy load
1.4Special Definitions — Class "B" Mercantile Store (Under 30,000 sq ft.)
1. 5 Classification of Occupancy — Mercantile Store Class "B"
1.6 Classification of Hazard of Contents — Ordinary in office areas, and storage area
classified as "High Hazard" per L.S.C. 101
1.7 Minimum Construction — Shall comply with Florida Building Code 2001
mercantile occupancy Type IV, UNPROTECTED
1
SANFORD FIRE DEPARTMENT
FIRE PREVENTION DIVISION
300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772
(407 302 2520 I FAX (407) 302-2526
1.8 2.2 Means of Egress Components Rear toraize exits, EXIT.: HALL BEDILINEATED
WITH 44" yellow paint on floor eadn to EXIT door's
2.3 Capacity of Egress — sales floor area based on one (])_person per 30 sq ft., storage area
based on one (1) person per 300 sq. ft.
2.4 Number of Exits — (Minimal of three (3) required EXITS
2.5 Arrangement of Egress: Travel distance increased up to 200' (ft) do to fire sprinkler system
XITSHALLBrEDFT�llowfpaofloor2.6 Travel Distance-wReaWI
leading to EXIT°door:;
2.7 Discharge from Exits — O.K., will field verify
2.8 Illumination of Means of Egress —additional EXIT SIGNS may be required (power shut
down test required at night only)
2.9 Emergency Lighting — (1) foot candle (10 Ix & a minimum at any point of 0.1
foot-candle (1 LX) measured along the path of egress at floor level. Therefore
additional emergency lights may be required, (power shut down test required at night
only)
Emergency Lightinjj required inside Main Electrical room and all rest rooms (*).
2.10 Marking of Means of Egress — O.K.; will field verify?
2.11 Special Features —Reserved
3.1 Protection of Vertical Openings — Class (B) mercantile shall have an automatic fire
sprinkler system. design criteria SHALL SHOW storaze maximum heieht in
storage area (*).
3.2 Protection from Hazards — (See exception 36-3.2.1 .LSC 10 1)
3.3 Interior Finish — Not required, building has an automatic fire sprinkler system
3.4 Detection, Alarm and Communications System: (as per N.F.PA.72- 3-8.3.1.2 (99)
Ed.
• 3.5 Extinguishing Requirements —as per NFPA 10, four (4) fire extinguishers required
per N.F RA... #10 See blue prints (Minimal 4A 60 B.C. Rated) M.
2
SANFORD FIRE DEPARTMENT
FIRE PREVENTION DIVISION
300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, FI. 32772
(407 302-2520 IFAX (407) 302-2526
5.1 Utilities — as per LSC 7-1
5.2 HVAC — as per LSC 7-2
5.3 Elevators, Escalators, Conveyors (4A-47) — N/A
Sanford City Code — Chapter9:
Required; Fire Sprinklers. Fire Department will field verify sight glass at all inspectors
test.
Monitoring: Required for fire sprinkler system and all inside and outside fire sprinkler valves.
Other: NFPA 1
3-5.1 Fire Lanes — Required if building is more than 150' from street; exception:
building has fire sprinkler system.
3-6.1 Key Box — One (D re uired see application attached
3-7.1 Bldg. Address Number Posted and Legible — Post address in 6" six inch numbers
contrasting in color (see blueprints).
3
Ir PFIF:TF1 f: hHIF Fix 770-394-13111 Ai:G IS '04 11 :12
A
REVISIONS
P 4 cid DATE
2J&104
ADDRESS
Jae
F A X # tT?CN 'm
UTILITIE$��������.
FIRE
-ilTA/0
i
I I F 1 SkN� k�'� _.
AUG 3 0 Z004R&L
_
-t
File' File 12
PHILLIPS
P A R T N E R S H I P
Architecture • Interior Design • Planning
Phone 770.394.1616
Fax 770.394.1314
To Brad Smith — Young Contracting
Address 1460 Rinehart
Sanford, Florida 32771
From Dwight Bailey
Date August 25, 2004
Copy
Address
Project The Seminole Marketplace At Towncenter
Project H 0208616
Sent For Your Use via Overnight Priority
H Copies Date Description
2 8/25/04 PetCo Permit Drawings to City of Sanford (See Attached Drawing List)
2 8/5/04 Pet Co Energy Efficiency Code for Building Construction
Comments:
Brad,
Please find the above referenced items for your use for permitting to the City of Sanford. Should you
have any questions please contact Dwight Bailey.
Thank you,
Jennifer Jenkins
Project Assistant
Phillips Partnership, PC
Initials
Seminole Marketplace
Phillips Project No. 0208616
List of Drawings
Updated 08/25/04
PETCO
ISSUE
DATE
ARCHITECTURAL
JA-0.1 Code Data, Project Data
Revision 13
July 26, 2004
JA-1.2 Building Shell Plan
Revision 13
July 26, 2004
JA-13 Sidewalk, RCP, & Storefront Plan
Revision 13
July 26, 2004
JA-2.4 Roof Plan
Revision 14
July 27, 2004
JA-3.1 Door Schedule, Finish Schedule & Door Types
May 14, 2004
JA-4.1 Exterior Elevations
Revision 13
July 26, 2004
JA-5.2 Exterior Wall Sections
Revision 13
July 26, 2004
JA-5.3 Exterior Wall Sections
Revision 13
July 26, 2004
JA-5.4 Exterior Wall Sections
Revision 13
July 26, 2004
JA-7.1 Large Scale Plans
Revision 13
July 26, 2004
STRUCTURAL
is-1.0
General Notes
Revision 3
May 28, 2004
JS-2.1
Foundation Plan
Revision 13
July 26, 2004
JS-3.1
Roof Framing Plan
Revision 14
July 27, 2004
JS-4.1
Foundation Details
Revision 3
May 28, 2004
JS-4.2
Foundation Details
Revision 13
July 26, 2004
JS-5.1
Framing Details
Revision 3
May 28, 2004
JS-5.2
Framing Details
Revision 3
May 28, 2004
JS-5.3
Framing Details
Revision 13
July 26, 2004
JS-6.1
Panel Elevations
Revision 13
July 26, 2004
JS-6.2
Panel Elevations
Revision 13
July 26, 2004
MECHANICAL
JMI.I
Shell Floor Plan HVAC
Revision 14
August 2, 2004
PLUMBING
JPI.I
Shell Floor Plan
Revision 17
July 26, 2004
ELECTRICAL
JEI.I
Shell Floor Plan
Revision 17
July 26, 2004
L,.
REVISIONS
•
PERMIT # 4 r2 rroa IDA . l^A
ADDRESS_?
CONTRACTOR ywmk6wmhaw—�—
PH #���Z,%O FAX # �TtO�TZZ•9�Lj3
nFSCPRITION OF REVISION:
UTILITIES
FIRE
BLDG
a
11