Loading...
HomeMy WebLinkAbout2201 WP Ball Blvd 04-2581 Revisions Petcoaaor w� �Au- e� �� � o�-ass � SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772 (407 302-2520 / FAX (407) 302-2526 Plans Review Sheet Date: June 17, 2004 Business Address: 2201 W.P. Ball Blvd. Occ. Ch. 36, Mercantile Class `B' Business Name: Petco Store Architect: Phillips Partnership Ph. (770) 394-1616 FAX (770)394-1314 P H (770) 394-1616 Fax. (770) 394-1314 Contractor: T.B.A. (out to bid at time of submittal) Ph. ( ) Reviewed by: Timothy Robles, Fire Protection Inspector/Plans Examinerz--X-�� Comment: Plans reviewed as Mercantile Occupancy. FD reserves right to require applicable code requirements if occupancy use changes. Sprinkler plans to be submitted for review, permitting, and inspections. Sealed letter from Engineer of Record stating design criteria for sprinkler system needs to be submitted with construction plans. Separate permit required for Fire Alarm. 1.1 Fire Alarm required for monitoring of sprinkler system 1.2Application — New Building (15,359 s. q. ft.) 1.3 Mixed — N/A, all restaurants under 50 occupancy load 1.4Special Definitions — Class "B" Mercantile Store (Under 30,000 sq ft.) 1. 5 Classification of Occupancy — Mercantile Store Class "B" 1.6 Classification of Hazard of Contents — Ordinary in office areas, and storage area classified as "High Hazard" per L.S.C. 101 1.7 Minimum Construction — Shall comply with Florida Building Code 2001 mercantile occupancy Type IV, UNPROTECTED 1 SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772 (407 302 2520 I FAX (407) 302-2526 1.8 2.2 Means of Egress Components Rear toraize exits, EXIT.: HALL BEDILINEATED WITH 44" yellow paint on floor eadn to EXIT door's 2.3 Capacity of Egress — sales floor area based on one (])_person per 30 sq ft., storage area based on one (1) person per 300 sq. ft. 2.4 Number of Exits — (Minimal of three (3) required EXITS 2.5 Arrangement of Egress: Travel distance increased up to 200' (ft) do to fire sprinkler system XITSHALLBrEDFT�llowfpaofloor2.6 Travel Distance-wReaWI leading to EXIT°door:; 2.7 Discharge from Exits — O.K., will field verify 2.8 Illumination of Means of Egress —additional EXIT SIGNS may be required (power shut down test required at night only) 2.9 Emergency Lighting — (1) foot candle (10 Ix & a minimum at any point of 0.1 foot-candle (1 LX) measured along the path of egress at floor level. Therefore additional emergency lights may be required, (power shut down test required at night only) Emergency Lightinjj required inside Main Electrical room and all rest rooms (*). 2.10 Marking of Means of Egress — O.K.; will field verify? 2.11 Special Features —Reserved 3.1 Protection of Vertical Openings — Class (B) mercantile shall have an automatic fire sprinkler system. design criteria SHALL SHOW storaze maximum heieht in storage area (*). 3.2 Protection from Hazards — (See exception 36-3.2.1 .LSC 10 1) 3.3 Interior Finish — Not required, building has an automatic fire sprinkler system 3.4 Detection, Alarm and Communications System: (as per N.F.PA.72- 3-8.3.1.2 (99) Ed. • 3.5 Extinguishing Requirements —as per NFPA 10, four (4) fire extinguishers required per N.F RA... #10 See blue prints (Minimal 4A 60 B.C. Rated) M. 2 SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, FI. 32772 (407 302-2520 IFAX (407) 302-2526 5.1 Utilities — as per LSC 7-1 5.2 HVAC — as per LSC 7-2 5.3 Elevators, Escalators, Conveyors (4A-47) — N/A Sanford City Code — Chapter9: Required; Fire Sprinklers. Fire Department will field verify sight glass at all inspectors test. Monitoring: Required for fire sprinkler system and all inside and outside fire sprinkler valves. Other: NFPA 1 3-5.1 Fire Lanes — Required if building is more than 150' from street; exception: building has fire sprinkler system. 3-6.1 Key Box — One (D re uired see application attached 3-7.1 Bldg. Address Number Posted and Legible — Post address in 6" six inch numbers contrasting in color (see blueprints). 3 Ir PFIF:TF1 f: hHIF Fix 770-394-13111 Ai:G IS '04 11 :12 A REVISIONS P 4 cid DATE 2J&104 ADDRESS Jae F A X # tT?CN 'm UTILITIE$��������. FIRE -ilTA/0 i I I F 1 SkN� k�'� _. AUG 3 0 Z004R&L _ -t File' File 12 PHILLIPS P A R T N E R S H I P Architecture • Interior Design • Planning Phone 770.394.1616 Fax 770.394.1314 To Brad Smith — Young Contracting Address 1460 Rinehart Sanford, Florida 32771 From Dwight Bailey Date August 25, 2004 Copy Address Project The Seminole Marketplace At Towncenter Project H 0208616 Sent For Your Use via Overnight Priority H Copies Date Description 2 8/25/04 PetCo Permit Drawings to City of Sanford (See Attached Drawing List) 2 8/5/04 Pet Co Energy Efficiency Code for Building Construction Comments: Brad, Please find the above referenced items for your use for permitting to the City of Sanford. Should you have any questions please contact Dwight Bailey. Thank you, Jennifer Jenkins Project Assistant Phillips Partnership, PC Initials Seminole Marketplace Phillips Project No. 0208616 List of Drawings Updated 08/25/04 PETCO ISSUE DATE ARCHITECTURAL JA-0.1 Code Data, Project Data Revision 13 July 26, 2004 JA-1.2 Building Shell Plan Revision 13 July 26, 2004 JA-13 Sidewalk, RCP, & Storefront Plan Revision 13 July 26, 2004 JA-2.4 Roof Plan Revision 14 July 27, 2004 JA-3.1 Door Schedule, Finish Schedule & Door Types May 14, 2004 JA-4.1 Exterior Elevations Revision 13 July 26, 2004 JA-5.2 Exterior Wall Sections Revision 13 July 26, 2004 JA-5.3 Exterior Wall Sections Revision 13 July 26, 2004 JA-5.4 Exterior Wall Sections Revision 13 July 26, 2004 JA-7.1 Large Scale Plans Revision 13 July 26, 2004 STRUCTURAL is-1.0 General Notes Revision 3 May 28, 2004 JS-2.1 Foundation Plan Revision 13 July 26, 2004 JS-3.1 Roof Framing Plan Revision 14 July 27, 2004 JS-4.1 Foundation Details Revision 3 May 28, 2004 JS-4.2 Foundation Details Revision 13 July 26, 2004 JS-5.1 Framing Details Revision 3 May 28, 2004 JS-5.2 Framing Details Revision 3 May 28, 2004 JS-5.3 Framing Details Revision 13 July 26, 2004 JS-6.1 Panel Elevations Revision 13 July 26, 2004 JS-6.2 Panel Elevations Revision 13 July 26, 2004 MECHANICAL JMI.I Shell Floor Plan HVAC Revision 14 August 2, 2004 PLUMBING JPI.I Shell Floor Plan Revision 17 July 26, 2004 ELECTRICAL JEI.I Shell Floor Plan Revision 17 July 26, 2004 L,. REVISIONS • PERMIT # 4 r2 rroa IDA . l^A ADDRESS_? CONTRACTOR ywmk6wmhaw—�— PH #���Z,%O FAX # �TtO�TZZ•9�Lj3 nFSCPRITION OF REVISION: UTILITIES FIRE BLDG a 11