Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
196 Towne Center Cir 03-2959 (new constr) (plans)
If7e CIA, INTERIOR ALTERATION SHELL PLANS FOR: RECREATIONAL FACTORY WAREHOUSE SPACE AO 1 SEMINOLE TOWNE CENTER SANFORD, FLORIDA v PROJECT DATA AREA OF IMPROVEMENT: PUBLIC TOILET FIXTURE COUNT: WATER CLOS'ETS URINAL LAVATORIES BUILDING CODE MECHANICAL CODE PLUMBING CODE ELECTRICAL CODE UFE SAFETY CODE FIRE CODE FLORIDA ACCESSIBILITY CODE ENERGY EFFICIENCY CODE CONSTRUCTION TYPE: AUTOMATIC FIRE SPRINKLERS OCCUPANCY TYPE: PREVIOUS USE: 5,057 SQ. FT. UNISEX EXIST. NEW I TOTAL 0 1 1 0 0 0 0 1 1 2001 FLORIDA BUILDING CODE 2001 FLORIDA MECHANICAL CODE 2001 FLORIDA PLUMBING CODE 1999 NEC 2000 NFPA 101 2001 FLORIDA FIRE PREVENTION CODE 2001 FLORIDA BUILDING CODE (CHAPTER 11) 2001 FLORIDA BUILDING CODE (CHAPTER 13) IV UNPROTECTED YES GROUP B — BUSINESS UNIMPROVED SHELL VICINITY MAP -- ,; of Lc t i r1, •.(Y Goa �.D Ld m , 0 r 44 €�v(IlsgrrPlacc��j'•_8`�k'jt�agSruff.prin9s ,YEnt[a�Fe�d`�z�f {s ...�K Pma Ct ........... art/ ` �j.._m {(�£ �ry.^^M1M1r � E E �n11'tdl ) w < v 7nrS Si1t�L JA Wllwn_Rd ................lrl ....................... 5A9a1 Enanoe fid '" tl' r•N � , n J ARCHITECTURAL SYMBOLS DETAIL LETTER OR NUMBER DETAIL SHEET WHERE DETAIL IS DRAWN SECTION LETTER OR NUMBER SECTION �# DIRECTION OF SECTION CUT SHEET WHERE SECTION IS DRAWN INTERIOR # ELEVATION LETTER OR NUMBER � ELEVATION ##� SHEET WHERE ELEVATION IS DRAWN QCOLUMN CENTER LINE COLUMN ;,� NUMBER # DOOR Q) p NUMBER ELEVATION * HEIGHT ABOVE FINISHED FLOOR (A.F.F.) By: Sanford Fire Pr Date: Cl INDEX OF DRAWINGS CS COVER SHEET / GEN. NOTES A-t FLOOR PLAN /ENLARGED RESTROOM PLAN / RESTROOM ELEVATIONS SCHEDULES /NOTES A-2 REFLECTED CEILING PLAN A-3 WALL SECTIONS / FIRE RATING DETAILS P-1 PLUMBING PLAN AND SCHEDULES M-1 HVAC NOTES AND SCHEDULES M-2 HVAC PLAN AND DETAILS E-1 ELECTRICAL AREA PLAN AND NOTES E-2 POWER &LIGHTING PLAN /SCHEDULES PROJECT GENERAL NOTES 1. THE CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR TO ANY WORK AND SHALL•BE RESPONSIBLE FOR ALL WORK AND MATERIALS INCLUDING THAT FURNISHED BY SUBCONTRACTORS_ 2. DIMENSIONS TAKE PRECEDENCE OVER DRAWINGS; DO NOT SCALE DRAWINGS TO DETERMINE ANY LOCATION_ THE OWNER SHALL BE NOTIFIED IF ANY DISCREPANCY OCCURS PRIOR TO CONTINUING WITH WORK. 3. DISCREPANCIES BETWEEN PORTIONS OF THE CONTRACT DOCUMENTS ARE NOT INTENDED_ THE CONTRACTOR IS TO. CLARIFY WITH THE ARCHITECT AND OWNER ANY SUCH DISCREPANCIES PRIOR TO COMMENCING WORK. 4, THE CONTRACTOR SHALL REPORT TO THE ARCHITECT ANY ERRORS, INCONSISTENCIES, OR OMISSIONS HE MAY DISCOVER. THE CONTRACTOR IS RESPONSIBLE FOR CORRECTING ANY ERRORS AFTER THE START OF CONSTRUCTION WHICH HAVE NOT BEEN BROUGHT TO THE ATTENTION OF THE ARCHITECT. THE MEANS OF CORRECTING ANY ERROR SHALL FIRST BE APPROVED BY -THE ARCHITECT AND OWNER. 5. ALL PLAN DIMENSIONS ARE FROM FACE OF STUD OR FACE OF FINISH OR FACE OF CMU UNLESS OTHERWISE NOTED. 6. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF ALL FEDERAL, STATE, LOCAL AND OSHA CODES AND LOCAL RESTRICTIONS. 7. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING MECHANICAL AND ELECTRICAL SERVICES AND DISTRIBUTION SYSTEMS WHETHER SHOWN OR NOT, AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL EXPENSE OR REPAIR OR REPLACEMENT OF UTILITIES OR OTHER PROPERTY DAMAGED BY OPERATIONS IN CONJUNCTION WITH THE PERFORMANCE OF THE WORK_ 8. 'FIRE EXTINGUISHERS - SIZE,TYPE,NUMBER AND LOCATION IS TO BE COORDINATED WITH THE BUILDING AND FIRE DEPARTMENTS. 9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPLACEMENT. OR REMEDY OF ANY FAULTY, IMPROPER OR INTERIOR MATERIALS OR WORKMANSHIP WHICH SHALL APPEAR WITHIN ONE (1) YEAR OR -AS OTHERWISE SPECIFIED FOR A SPECIFIC COMPONENT AFTER THE COMPLETION AND ACCEPTANCE OF THE WORK UNDER THIS CONTRACT. 10_ THE CONTRACTOR SHALL PROVIDE BACKING/BLOCKING AS REQUIRED FOR MOUNTING OF WALL MOUNTED SHELVES AND CABINETS. ALL WOOD BLOCKING, PLYWOOD SHEATHING, SUB -FLOORING AND WOOD FRAMING CONCEALED WITHIN WALL, FLOOR OR CEILING SPACES SHALL BE PRESSURE. TREATED WHEN INSTALLED AGAINST CONCRETE BLOCK. 11. SILICONE CAULK SHALL BE USED AT THE FOLLOWING LOCATIONS INCLUDING, BUT NOT LIMITED TO: 1. METAL DOOR AND WALL CONNECTION 2. CONDUIT AND PIPE PENETRATIONS AT WALLS AND CEILING. 3. JUNCTION OF MILLWORK (CABINETS, SHELVES, ETC_). 12. CONTRACTOR IS TO CLEAN WORK AREAS ON A DAILY BASIS SO AS NOT TO ACCUMULATE DEBRIS. 13. UPON PROJECT COMPLETION CONTRACTOR IS TO CLEAN WORK AREAS AND JOB SITE THOROUGHLY SO AS TO REMOVE ALL ONSTRUCTION DUST, RESIDUE, AND DEBRIS. 14_ DO NOT OBSTRUCT STREETS, SIDEWALKS, ALLEYS OR OTHER RIGHT-OF-WAY WITHOUT FIRST OBTAINING PROPER PERMITS. 15. ALL WORK SHALL BE ACCOMPLISHED WITH QUALITY WORKMANSHIP OF THE HIGHEST INDUSTRY STANDARDS. ALL MATERIALS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS AND RECOMMENDATIONS. MATERIALS AND METHODS SHALL CONFORM TO THE APPROPRIATE NATIONAL TRADE BOOK; I.E. TILE COUNCIL OF AMERICA HANDBOOK FOR CERAMIC TILE INSTALLATION, ARCHITECTURAL WOODWORK INSTITUTE, "QUALITY STANDARDS," ETC. 1. 16. THE OWNER MAY PERFORM ADDITIONAL WORK THAT IS NOT PART OF THIS CONTACT WITH HIS OWN FORCES, UNDER SEPARATE CONTRACTS AND/OR WITH OTHER CONTRACTORS. THE CONTRACTOR SHALL COOPERATE WITH THE OWNER AND OTHER CONTRACTORS AND COORDINATE HIS WORK WITH THE OWNER SC THAT THE WORK BY OTHERS CAN BE INCORPORATED IN A TIMELY MANNER. 17. THE CONTRACTOR SHALL BE RESPONSIBLE FOR JOB SAFETY, AND SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE SAFETY OF WORKS AND OCCUPANTS AT ALL TIMES. 18_ ALL ELECTRICAL, MECHANICAL, AND PLUMBING WORK SHALL CONFORM TO STATE AND LOCAL REQUIREMENTS. 19, REMODEL WORK SHALL NOT OBSTRUCT, OR CAUSE TO BE INOPERATIVE, EXISTING FIRE ALARM SYSTEMS. MODIFICATION TO FIRE ALARM SYSTEMS SHALL BE PERFORMED BY A 111RE ALARM CONTRACTOR, WHO SHALL OBTAIN A PERMIT FROM THE BUILDING DEPT. PRIOR T!? WORK. 20. THE CONTRACTOR SHALL MAINTAIN, IN GOOD CONDITION, ONE COMPLETE SET OF CONSTRUCTION DOCUMENTS WITH ALL REVISIONS, ADDENDUMS AND CHANGE ORDERS ON THE PREMISES AT ALL TIMES. THE DOCUMENTS ARE TO BE KEPT UNDER THE CARE OF THE JOB SUPERINTENDENT. 21 _ THE CONTRACTOR SHALL FURNISH AND INSTALL ALL MINOR ITEMS WHICH ARE OBVIOUSLY AND REASONABLE NECESSARY TO COMPLETE ANY INSTALLATION. 22. IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO ISOLATE ALL WORK AREAS IN SUCH A WAY AS TO PROTECT THE ADJACENT BUILDING SPACES AND STRUCTURE. 23. MINIMUM FLAME SPREAD CLASSIFICATION OF INTERIOR FINISH SHALL CONFORM TO THE BUILDING CODE AND LOCAL GOVERNING BUILDING CODES/ORDINANCES. 24. ACCEPT PREMISES AS FOUND. OWNER ASSUMES NO RESPONSIBILITY FOR THE CONDITION OF THE EXISTING BUILDING SITE OR EXISTING STRUCTURES AT THE TIME OF BIDDING OR THERE AFTER. 25. GYPSUM WALLBOARD AND SUSPENDED CEILING SYSTEMS SHALL CONFORM TO REQUIREMENTS OF LOCAL BUILDING CODES AND ORDINANCES. 26. IT IS THE RESPONSIBILITY OF THE GENERAL. CONTRACTOR TO SECURE ALL NECESSARY PERMITS AND APPLICATIONS. 27. ALL NEW DRYWALL AND ABUTTING SURFACES ARE TO BE FINISHED TO A SMOOTH PAINTABLE SURFACE. 28. ALL EXISTING INTERIOR WALLS ARE TO BE PATCHED AND POINTED UP AS REQUIRED TO PROVIDE A SMOOTH UNIFORM PAINTABLE SURFACE, 29. GYPSUM WALL BOARD SHALL BE INSTALLED WITH ALL CORNER BEADS, TRIM, ACCESSORIES, MOULDINGS, ETC., AS REQUIRED FOR COMPLETION, TAPED AND SANDED READY FOR PAINT BY DRYWALL CONTRACTOR. ALL WORK WILL BE PERFORMED IN ACCORDANCE WITH U.S. GYPSUM STANDARDS. 30. UPON COMPLETION OF WORK THE GENERAL CONTRACTOR SHALL CLEAN ALL WINDOWS (INTERIOR AND EXTERIOR), JAMBS, CLEAN, SEAL AND WAX ALL VINYL TILE FLOORS, ALL TOILET ROOMS, SALES FLOOR CAREFULLY REMOVING THOROUGHLY ALL TAPE, LABELS, AND OTHER CONSTRUCTION DIRT AND DEBRIS. I INTERIOR FINISH FIRE CHARACTERISTICS MAXIMUM FLAME SPREAD CLASSIFICATION SHALL COMPLY WITH THE 1997 SBC FLAME SPREAD RATINGS CLASS FLAME SPREAD FUEL CONTRIBUTION SMOKE DENSITY PLASTIC LAMINATES --- 165 --- 135 EPDXY PAINT FINISH A / 1 10 0 0 ACOUSTICAL TILE A 0-25 --- --- J m to I z 0 V) W a 0 z � N TTTT rEt 0 ® O � U t(� w n o CD `/ 1 h�..� to CD CDto • to 0000 �V)LLJ ��bo� o xw c CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECT OF ANY DIMENSIONAL ERRORS, OMISSIONS OR DISCREPANCIES BEFORE BEGINING OR FABRICATING ANY WORK. DO NOT SCALE DRAWINGS. O Li.. F�1 to 0 Ld CL 1-- < Lj 0 �0 �z� U 0 OPT CLWo CL ~ V) —� w E-1 o a W n W S a iQ ''I DRAWN BJ _ CHECKED JR,1J DATE 09/02/03 SCALE AS NOTED PROJECT NO. H32503 FILE NAME 2503CSU SHEET c s i ROOM FINISH SCHEDULE ROOM FLOOR BASE WALLS CEILING HEIGHT SALES AREA BY TENANT WOOD PAINT ALL WALLS NEW ACOUST. 14'-0" RESTROOM VINYL VINYL PAINT ALL WALLS NEW ACOUST, 8'-0" STOCK ROOM CONC. VINYL PAINT ALL WALLS NEW ACOUST, 14'-0" FINISH NOTES VINYL FLOORING SHEET VINYL FLOORING IS TO BE SELECTED AND PROVIDED BY TENANT. GENERAL CONTRACTOR TO INSTALL ALL VINYL FLOORING. NOTE: PROVIDE VINYL TRANSITION STRIP BETWEEN AREAS WITH CARPET AND AREA WITH VINYL. VINYL BASE 4" VINYL BASE SELECTED AND PROVIDED BY TENANT. INSTALLED BY GENERAL CONTRACTOR. WALL PAINT ONE (1) COAT VINYL PRIMER PLUS TWO (2) COATS VINYL PLASTIC PAINT (EGGSHELL FINISH). NEW 1x4 WOOD BASE (FIR) ONE (1) COAT ENAMEL UNDERCOAT PLUS TWO (2) COATS SEMI -GLOSS. NEW WOOD DOORS/FRAMES ONE (1) COAT ENAMEL UNDERCOAT PLUS TWO (2) COATS SEMI -GLOSS. NEW METAL DOOR FRAMES ONE (1) COAT ENAMEL UNDERCOAT PLUS TWO (2) COATS SEMI -GLOSS. DOOR SCHEDULE # SIZE THK. MATERIAL FRAME TYPE REMARKS HARDWARE E1. 3'-0"x6'-8" 1-3/4" METAL EXIST. FLUSH REPLACE EXIST. EXIT DOOR 2 1. 16'-0"x13'-O" - ALUM. ALUM. - OVERHEAD ROLLING GRILLE 2 3'-0"x6'-8" 1-3/4" WOOD METAL FLUSH NEW INTERIOR DOOR 1 DOOR NOTES: (PROVIDE HARDWARE AS SPECIFIED OR EQUAL TO) 1. ALL NEW WOOD DOORS ARE TO BE PAINT GRADE BIRCH. 2. LOCKING DEVICES ON REQUIRED EXIT DOORS SHALL NOT REQUIRE THE USE OF A KEY FOR OPERATION FROM INSIDE THE BUILDING. 3. DOOR LOCKSETS/PASSAGE SETS ARE TO BE SCHLAGE LOCKS WITH LEVER ACTION HANDLES. 4. CONTRACTOR IS TO ADJUST ALL DOORS TO NORMAL WORKING OPERATION WHICH INCLUDES THE REPAIR OR REPLACEMENT OF HARDWARE AND WEATHER STRIPPING AS REQUIRED. 5. UNDER CUT INTERIOR DOORS 1/2." 6. REUSE ALL UNDAMAGED EXISTING DOORS, FRAMES AND DOOR HARDWARE. EXCEPTION: REPLACE ALL DOOR KNOBS WITH NEW SCHLAGE DOOR LEVER HANDLES. GROUP #1 1-1/2 PR. BUTTS SELF CLOSING SPRING HINGES 4-1/2 X 4-1/2 1 LOCKSET SCHLAGE 2-3/4" BSXASA • i WALL MOUNTED DOOR STOP IVEY GROUP REUSE AND REMOUNT EXISTING HARDWARE. EXISTING METAL DOOR FRAME TO REMAIN AS IS. WALL TYPES LEGEND: z, FULL HEIGHT PARTITION TO CEILING GRID. SEE WALL SECTIONS ON SHEET A-2. INTERIOR FINISH REQUIREMENTS: MINIMUM FLAME SPREAD CLASSIFICATIONS: EXITS - CLASS C. - FLAME SPREAD 76-200, SMOKE DEVELOPED 0-450. EXITS ACCESS - CLASS C.- FLAME SPREAD 76-200, SMOKE DEVELOPED 0-450. OTHER SPACES - CLASS C.- FLAME SPREAD 76-200, SMOKE DEVELOPED 0-450. ELECTRICAL LEGEND NEW 110 V. 3 POLE DUPLEX OUTLET. CIRCUIT AS REQUIRED. NEW JUNCTION BOX FOR TELEPHONE. 1" CONDUIT TO ABOVE CEILING W/ PULL STRINGS © NEW JUNCTION BOX FOR COMPUTER CABLING. 1- CONDUIT W/ PULL STRINGS NEW 110V 3 POLE FOURPLEX OUTLET CIRCUIT AS REQUIRED NEW 11OV 3 POLE DUPLEX OUTLET MOUNTED ®C ABOVE THE CEILING ON THE WALL NEW FLOOR MOUNTED TELEPHONE JUNCTION BOX WITH 1" OF CONDUIT OVER WALL AND UP WALL TO ABOVE CEILING W/ PULL STRINGS ® NEW FLOOR MOUNTED DEDICATED DUPLEX COMPUTER OUTLET F (b NEW SPECIAL PURPOSE OUTLET FOR STACK WASHER AND DRYER N = NEW DEVICE R = RELOCATED DEVICE DEVICES WITHOUT DESIGNATION ARE EXISTING © NEW JUNCTION BOX AND SWITCH FOR WATER HEATER 220 V, 3 PH. ® 41" A.F.F. NEW SURFACE PAINTED MOUNTED PAPER GYP. BD . TOWEL DISPENSER - NEW GRAB BARS MIRROR PROVIDE BLOCKING AS REQUIRED FOR SUPPORT NEW SURFACE MOUNTED TOILET TISSUE HOLDER 4" 3'-0" 0) NEW SINK I - N NEW WRAP DRAIN WATER CLOSET 1'-6" 3'-2" PIPE WITH rw CLEAR INSULATION A RESTROOM ELEVATION SCALE 1/2" = 1'-On PLUMBING EQUIPMENT SCHEDULE REF ITEM MFR & CAT. NO. REMARKS WCO WALL CLEANOUT JOSAM 58890-20 WALL CLEANOUT FCO FLOOR CLEANOUT JOSAM 56064-14 W/ CARPET COVER FD-A 3" FLOOR SINK DRAIN W/ NIKALOY TOP JOSAM 30003-7A-50 REMARKS WH WALL HYDRANT JOSAM 71020 - PDI-* SHOCK ABSORBER - '*' SIZE PRECISION PLMB TYPE SC PROVIDE ACCESS PANEL TPV TRAP PRIMER VALVE PRECISION PLMBTYPE P1 PROVIDE ACCESS PANEL PLUMBING FIXTURE SCHEDULE REF ITEM MFR & CAT. NO. WASTE TRAP VENT H.W. C.W. WC-1 WATER CLOSET - HANDICAPPED: AMERICAN STANDARD 3 INT. 2 - 1/2 VITREOUS CHINA, FLUSH TANK, SIPHON JET, ELONGATED 2108.408 BOWL, 12- ROUGHING, FLOOR MOUNTED, WATER SAVER TYPE, OLSONITE SEAT 19" A.F.F., WHITE SOLID PLASTIC SEAT, OPEN FRONT 47SSTL-SSR CHECK HINGE, CHROME PLATED 3/8" SUPPLY W/ANGLE McGUIRE 166 STOP AND WROT. ESCUT. L-1 WALL HUNG LAVATORY - HANDICAPPED: AMERICAN STANDARD 2 1 1/4 1 1/4 1/2 1/2 VITREOUS CHINA, 18" X 15" PERFORATED STRAINER WITH 1 0373.027 1/4" OFFSET TAILPIECE. CHROME PLATED 3/8" SUPPLY McGUIRE 155-WC W/ANGLE STOP & WROT ESCUTCHEON OFFSET, CHROME BRASS P-TRAP, 17 GA. WITH ESCUTCHEON WALL MTD. McGUIRE 158WC CARRIER W/HANGER PLATE, CONCEALED ARMS. FAUCET WITH McGUIRE 8902 AERATOR, 4- WRIST BLADES 0.5 GPM FLOW, ON 4" CENTERS JOSAM OR ZURN CHICAGO 802A-317 MS-1 MOP SINK 1/2 1/2 DF-1 DRINKING FOUNTAIN HALSEY TAYLOR 1-1/4 1-1/4 1-1/4 3/8 STANDARD STAINLESS STEEL FINISH OVL-11 S FLOOR PLAN KEY NOTESED 1- NEW CONCRETE FLOOR SLAB (2500 PSI WITH FIBER MESH) WITH GEOTEXTILE WATERPROOFING LINER. PROVIDE CRACK CONTROL JOINTS ® 15 FT. O.C. EACH WAY. 2. NEW SUITE SERVICE ELECTRICAL PANEL. 3. NEW STEP DOWN TRANSFORMER. 4. NEW DUPLEX RECEPTACLE OUTLET. 5. NEW PARTITION WALL W/ 3-5/8" 25GA. METAL STUDS 16" O.C. AND 5/8" GYP. BD. BOTH SIDES. 6. FURR OUT EXISTING WALL WITH 3-5/8" 25GA. METAL STUDS ® 16" O.C. AND 5/8" GYP. BD. ONE SIDE. 7. INSTALL NEW 5/8" TYPE 'X' GYP. BD. OVER ONE SIDE OF EXISTING MTL. STUDS. 8. BOX OUT EXISTING COLUMN WITH 3 5/8" 25 GA. MTL. STUDS AND 5/8" TYPE 'X' GYP. BD. ONE SIDE. 9. BOX (.i EXISTING RAIN LEADER WITH 3 5/8" 25 GA. MTL. STUDS AND 5/8" TYPE 'X' GYP. BD. ONE SIDE. 10. PROVIDE BLOCKING AND ADDITIONAL METAL STUD SUPPORTS AS REQUIRED FOR WATER HEATER SUPPORT SHELF. 11, INSTALL NEW 2 LAYERS 5/8" TYPE 'X' GYP. BD, ONE SIDE OVER EXISTING METAL STUDS. NEW GRAB BARS PROVIDE BLOCKING AS REQUIRED FOR SUPPORT —1 3'-6" NEW SURFACE MTD. TOILET TISSUE HOLDER I C`l - NEW WATER CLOSET B RESTROOM ELEVATION SCALE 1/2' = 1'-0" MIIV. MHx. EQUIPMENT PERMITTED IN SHADED AREA HANDICAP WATER BUBBLER DETAIL SCALE: 1' = 1'-0" CONTRACTOR IS TO INSTALL NEW PLUMBING PIPING INTO NEW STUD WALL AND NOT INTO EXISTING FIRE -RATED WALL L-1 -" - 1 6 — 3 3 2' 8" I B A II A-1 A-1 'T" SHAPED HANDICAP LACCESSIBLE TURNAROUND------� RESTROOM �# DFTND01 D.DWG 1— O 1�_IX/j, DF-1 MS-1 00, LNEW WATER HEATER MOUNTED ABOVE. - �r , 4 7'_ 5 L r�5)3 41 � ENLARGED RESTROOM PLAN SCALE: 1/2' = 1'-0" SUITE GENERAL NOTES 1. CK. G� U 0 F- to X W ELECTRICAL GENERAL NOTES 1. SEE ELECTRICAL DRAWINGS ('E' SHEETS) IN THIS SET OF PLANS FOR SCOPE AND SPECIFICATIONS FOR THE ELECTRICAL WORK. HVAC GENERAL NOTES 1. SEE MECHANICAL / HVAC DRAWINGS ('M' SHEETS) IN THIS SET OF PLANS FOR SCOPE AND SPECIFICATIONS FOR THE MECHANICAL / HVAC WORK. PLUMBING GENERAL NOTES 1- SEE PLUMBING ('P' SHEET) DRAWINGS IN THIS SET OF PLANS FOR SCOPE AND SPECIFICATIONS FOR THE PLUMBING WORK. SCALE: 1/4" = 1'-0" I m it vI z 0 5) 4:1 W Q 0 ZN O U � 0 A Is- 0 E-+ p CL 0 Cw n co `n Q v� Z o a I N • Lo 00 W� � -H C!1 Z v� o ,� o E o 0 4 Uwe W N r I H a � H ��4 cn o E U 0 ��. y n CL 77 V) V N CONTRACTOR SHALLERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECT CL OF ANY DIMENSIONAL ERRORS, OMISSIONS OR DISCREPANCIES BEFORE BEGINING OR FABRICATING ANY WORK. DO NOT SCALE DRAWINGS. 0 0 0 v B A-3 L U Q ,• V V 4d L O CD (� I o co o ck: CL W CL W z® W J _ULLI oc V cn � 4 W 0o azLL- �I V O 0 � C��-1 H ®� W O LL F--ri V) __.! w Ems; Oz Q -< W W N O c � W�3 L v � Li u) f a> � v N O o V � DRAWN BJ CHECKED JRJJ DATE 09/02/03 SCALE AS NOTED PROJECT NO. H32503 FILE NAME 2503A1U SHEET A. -� 1 CEILING PLAN LEGEND 2x2 FLUORESCENT LIGHT FIXTURE WITH 9 CELL PARABOLIC LENS 2x4 FLUORESCENT LIGHT FIXTURE VALL'MOUNTED 'EXIT ' LIGHVI' (BUrILDING STANDARD) WALL MOUNTED EMERGENCY LIGHT. (BUILDING STANDARD) CEILING MOUNTED EXHAUST FAN. LOREN—COOK GEMINI CEILING FAN MODEL — 720, 650 CFM @ 0.25 STATIC OR EQUAL. PROVIDE EXHAUST FAN WITH WALL CAP, GRAVITY BACK DRAFT DAMPER, BIRD SCREEN EXHAUST GRILLE AND R.A. THERMOSTAT. SUPPLY AIR DIFFUSER RETURN AIR GRILLE NEW 2x2 SUSPENDED ACOUSTICAL CEILING GRID SYSTEM NEW 2x4 SUSPENDED ACOUSTICAL CEILING GRID SYSTEM NO DESIGNATION = EXISTING DEVICE R = RELOCATED DEVICE N = NEW DEVICE o FIRE SPRINKLER HEAD K.3 J RESTROOM 0 H Fire U00 iw�, �-Lo f- �30�� JUNCTION BOX FdR SIGN CIRCUIT. SIGN IS TO BE SUPPLI D AND INSTALLED BY THE TENANT. REFLECTED CEILING_ PLAN SCALE: 1/4" = 1'-O" rI m i Z W Q O to N rn C D F+ CD oo f U a r- Q ``' o v U o �n oo uj V l o W ? L" T N Q �^\ C) [ve�t� IF'---'•1j �/ O C-' O U w r'- �. L E4 �_q �7, U U vi CIO Ix l 'a� J o a> L E U O N to "' sn a 'p V N Q N 0. C ci% L yfni L CONTRACR SHALL� ALL CONDT VERIFY ITIONS AND DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECT a OF' ANY DIMENSIONAL ERRORS, OMISSIONS OR DISCREPANCIES BEFORE BEGINING OR FABRICATING ANY WORK. DO, NOT SCALE DRAWINGS. V L o L 0 e- 0 V C V W t V L Q U7 .. .V O 0 O N 2 Z 0 0 W CL Lj w U� c.� cy- LLJU +rr �Wo o Z fJ LL- U ® ci:� W O H V) Z V Z Q V) LL w w cn cy— rn W F�— Z v 8 N = U O 0 Q DRAWN BJ CHECKED JRJJ DATE 09/02/03 SCALE AS NOTED PROJECT NO. H32503 FILE NAME 2503A2U SHEET A-2 A "'U I ILtVA I IUN SCALE: 1/4" 1'-0" EXIST, 5/8" TYPE "X" CUT IN BOX - 2G GYP. BD. @ BOTH @ 24" A.F_F. SIDES OF STUDS L EXIST. 6" L-4" SQ. BOX METAL STUDS @ 18" A.F.F_ INSERT METACAULK BOX GUARD, BY RECTORSEAL, INTO ALL ELECTRICAL BOXES IN FIRE RATED WALLS, INSERT ONTO THE INSIDE BACK WALL OF THE BOX_ METACAULK BOX GUARD IS A ONE COMPONENT FIRE RATED PAD AND IS A HIGHLY INTUMESCENT FIRESTOP MATERIAL. SEE ATTACHED DATA SHEETS. 11 ELECTRICAL BOX PENETRATION DETAIL SCALE: 1" = 1'-0" ELEC PENETRATION SYSTEM NO. W-L-1006 (FORMERLY SYSTEM NO. 187) FRATING -2HR TRATING -0HR L,B SECTION B-B 1. WALL ASSEMBLY -THE FIRE -RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES WALL AND PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTON FEATURES: A. STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. LUMBER SPACED 16 IN. Q.C. STEEL STUDS TO BE MIN 2-1/2 IN. WIDE AND SPACED MAX 24 IN. O.C_ B. WALLBOARD, GYPSUM* - TWO LAYERS OF NOM 5/8 IN. THICK GYPSUM WALLBOARD, AS SPECIFIED IN HE INDIVIDUAL WALL AND PARTITION DESIGN. MAX. DIAM OF OPENING IS 2 IN. 2. THROUGH PENETRANTS - ONE METLIC PIPE, CONDUIT OR TUBING TO BE CENTERED WITHIN THE FIRESTOP SYSTEM. PIPE, CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF METALLIC PIPE, CONDUIT OR TUBING MAY BE USED: A- STEEL PIPE N6 IN. IS RK"QUIREDWITHIN THEOP SYSTEM. STEEL PIPE. A NOM ANNULARSPACE OF 5/N.IS B. CONDUIT - NOM 1 IN. DIM (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING OR RIGID STEEL CONDUIT. A NOM ANNULAR SPACE OF 5/16 IN. IS REQUIRED WITHIN THE FIRESTOP SYSTEM. C AONOMRTUBING - NOM 1 ANNULAR SPACE OFN. 5/116 DIAM IS REQUIRED WITHIN TYPE L THE FIRESOR TOP SYCPPER TUBING. STEM D. COPPER PIPE - NOM 1 IN. DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE. A NOM ANNULAR SPACE OF 5/16 IN. IS REQUIRED WITHIN THE FIRESTOP SYSTEM. 3. FIRESTOP SYSTEM - THE FIRESTOP SYSTEM SHALL CONSIST OF THE FOLLOWING: A. FILL, VOID OR CAVITY MATERIAL* PUTTY - MIN 1-1/2 IN. THICKNESS OF FILL MATERIAL APPLIED WITHIN THE ANNULUS, ON BOTH SURFACES OF WALL_ ADDITIONAL FILL MATERIAL TO BE INSTALLED SUCH THAT A MIN 1/8 IN. CROWN IS FORMED AROUND THE PENETRATING ITEM. NELSON FIRESTOP PRODUCTS TYPES FSP PUTTY AND FSP FIRESTOP PUTTY PADS *BEARING THE UL CLASSIFICATION MARKING 10 PIPE PENETRATION DETAIL N.T.S. DESIGN NO. U465 NONBEARING WALL RATING -1 HR. 02 4 1. FLOOR AND CEILING RUNNERS - (NOT SHOWN) CHANNEL SHAPED RUNNERS, 3-5/8 IN. WIDE (MIN), 1-1/4 IN. LEGS, FORMED FROM NO. 25 MSG (MIN. NO. 20 MSG WHEN ITEM 4C IS USED) GLAV STEEL, ATTACHED TO FLOOR AND CEILING WITH FASTENERS SPACED 24 IN. OC MAX. 2. STEEL RETURNS,UFORMED FROMLNO. 25DMSG (MIN IN. NOW20 IDE MSG )WHEN1 ITEMIN. 4CLEGS S USED)IN. GALVFOLDED BACK STEEL SPACED 24 IN, OC MAX. 3. BATTS AND BLANKETS*- (OPTIONAL) - MINERAL WOOL OR GLASS FIBER BATTS PARTIALLY OR COMPLETELY FILLING STUD CAVITY. SEE BATTS AND BLANKETS (BZJZ) CATEGORY FOR NAMES OF CLASSIFIED COMPANIES, 4. WALLBOARD, GYPSUM *-5/8 IN. THICK, 4 FT. WIDE, ATTACHED TO STEEL STUDS AND FLOOR AND CEILING TRACK WITH 1 IN. LONG, TYPE S STEEL SCREWS SPACED 8 IN. OC. ALONG EDGES OF BOARD AND 12 IN_ OC. IN THE FIELD OF THE BOARD. JOINTS ORIENTED VERTICALLY AND STAGGERED ON OPPOSITE SIDES OF THE ASSEMBLY. WHEN ATTACHED TO ITEM 6 (FURRING CHANNELS), WALLBOARD IS SCREW ATTACHED TO FURRING CHANNELS WITH 1 IN. LONG, TYPE S STEEL SCREWS SPACED 12 IN. OC. AMERICAN GYPSUM CO. - TYPE AG-C CANADIAN GYPSUM CO. - TYPES AR, C, IP-X2, SCX, SHX, WRC OR WRX. CELOTEX CORP. - TYPE 1. CONTINENTAL GYPSUM COMPANY - TYPES CG-C, CG5-5, CG6-6, CG9-9, CGTC-C. G-P GYPSUM CORP, SUB OF GEORGIA-PACIFIC CORP - TYPES 5, 9, C, GPFS6. JAMES HARDIE GYPSUM - TYPE BG-C. LAFARGE GYPSUM, A DIV. OF LAFARGE CORP_ - TYPES LGFC2, LGFC2A, LGFC6, LGFC6A, LGFC-C. NATIONAL GYPSUM CO - TYPES FSK-G, FSW-G. NATIONAL GYPSUM CO - TYPES FIR OR WR. PABCO GYPSUM, DIV OF PACIFIC COAST BUILDING PRODUCTS INC - TYPE PG-C. REPUBLIC GYPSUM CO. - TYPE RG-C_ STANDARD GYPSUM CORP_ - SG-C TEMPLE -INLAND FOREST PRODUCTS CORP. - TYPE TG-C. UNITED STATES GYPSUM CO. - TYPE AR, C, FRX-G, IP-X2, SCX, SHX, WRC OR WRX. YESO PANAMERICANO SA DE CV - TYPE AR, C, IP-X2, SCX, SHX, WRC OR WRX. WESTROC INC. - TYPE WESTROC FIREBOARD. 4A. WALLBOARD, GYPSUM* - (AS AN ALTERNATE TO ITEM 4) - NOM 3/4 IN. THICK, 4 FT WIDE, INSTALLED AS DESCRIBED IN ITEM 4 WITH SCREW LENGTH INCREASED TO 1-1/4 IN. CANADIN GYPSUM COMPANY - TYPE AR_ UNITED STATES GYPSUM CO. - TYPE AR. YESO PANAMERICANO SA DE C V - TYPE AR. 4C_ WALLBOARD GYPSUM*- (AS AN ALTERNATE TO ITEMS 4, 4A AND 48) - 5/8 IN. THICK GYPSUM PANELS, INSTALLED AS DESCRIBED IN ITEM 4 WITH TYPE S-12 STEEL SCREWS_ THE LENGTH AND SPACING OF THE SCREWS AS SPECIFIED UNDER ITEM 4. CANADIN GYPSUM COMPANY - TYPE FRX. UNITED STATES GYPSUM CO. - TYPE FRX. 5_ JOINT TAPE AND COMPOUND - VINYL, DRY OR PREMIXED JOINT COMPOUND, APPLIED IN TWO COATS TO JOINTS AND SCREW HEADS; PAPER TAPE, 2 IN. WIDE, EMBEDDED IN FIRST LAYER OF COMPOUND OVER ALL JOINTS. AS AN ALTERNATE, NOMINAL 3/32 IN. THICK GYPSUM VENEER PLASTER MAY BE APPLIED TO THE ENTIRE SURFACE OF CLASSIFIED VENEER BASEBOARD. JOINTS REINFORCED. 6. FURRING CHANNEL - (OPTIONAL -NOT SHOWN) - RESILIENT 25 MSG GALV. STEEL FURRING CHANNELS SPACED VERTICALLY MAX 24 IN. OC, FLANGE PORTION ATTACHED TO EACH INTERSECTING STUD WITH 1/2 IN. LONG TYPE S-12 PANHEAD STEEL SCREWS. NOT FOR USE WITH TYPE FRX GYPSUM PANELS. *BEARING THE UL CLASSIFICATION MARKING. 1 " I0� NEW CEILIN NEW ' GYP. OVER GA. P 16" C EXISTI WALL NEW COVE NEW -11 1/2 NEUTRAL. S06 BOTT. 10'-0" )f STORE FRONT TOP OF Q, FRJ. FLR. SYSTEM NO. WL1017 (FORMERLY SYSTEM NO. 328) F RATING - 1,2 HR (SEE ITEM 3) T RATING - 0 HR L RATING AT AMBIENT - LESS THAN 1 CFM/SQ FT L RATING AT 400 F - LESS THAN 1 CFM/SQ FT SECTION A -A 1. WALL ASSEMBLY -THE 1 OR 2 HR FIRE RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY SHALL BE CON- STRUCTED OF THE MATERIALS AND IN THE MANNER DESCRIBED IN THE INDIVIDUAL U300 OR U400 SERIES WALL OR PARTITION DESIGN IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTON FEATURES: A. STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS, WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. LUMBER SPACED 16 IN. O.C. WITH NOM 2 BY 4 IN. LUMBER END PLATES AND CROSS BRACES. STEEL STUDS TO BE MIN. 3-5/8 IN.WIDE BY 1-3/8 IN. DEEP CHANNELS SPACED MAX. 24 IN. O.C. B. WALLBOARD, GYPSUM* - NOM 5/8 IN. THICK, 4 FT. WIDE WITH SQUARE OR TAPERED EDGES. -THE GYPSUM WALLBOARD TYPE, NUMBER OF LAYERS, AND SHEET ORIENTATION SHALL BE AS SPECIFIED IN THE INDIVIDUAL WALL OR PARTITION DESIGN. DIAM OF CIRCULAR CUT THROUGH GYPSUM WALL- BOARD ON EACH SIDE OF WALL ASSEMBLY TO BE MIN. 0 IN. (POINT CONTACT) TO MAX 1 IN. LARGER THAN OUTSIDE DIAM OF FLEXIBLE METAL CONDUIT (ITEM 2) INSTALLED IN THROUGH OPEN- ING. SIDE EDGE OF CIRCULAR OPENING TO BE MIN. 3 IN. FROM NEAREST STUD IN 'NALL CAVITY. C. FASTENERS •- WHEN WOOD STUD FRAMING IS EMPLOYED, GYPSUM WALLBOARD ATTACHED TO STUDS WITH CEMENT COATED; NAILS AS SPECIFIED IN THE INDIVISUAL WALL OR PARTITION DESIGN. WHEN STEEL CHANNEL STUD FRAMING IS EMPLOYED, GYPSUM WALLBOARD ATTI;HED TO STUDS WITH TYPE S SELF -DRILLING, SELF -TAPPING BULGE -HEAD STEEL SCREWS AS SPECIFIED IN THE INDIVISUAL WALL OR PARTITION DESIGN. 2. THROUGH PENETRANTING PRODUCT* - FLEXIBLE METAL CONDUIT - NOM 4 IN. DIM (OR SMALLER) ALUMINUM OR STEEL FLEXIBLE METAL CONDUIT+. MAX ONE FLEXIBLE METAL CONDUIT TO BE INSTALLED NEAR CENTER OF CIRCULAR OPENING IN GYPSUM WALLBOARD. FLEXIBLE METAL CONDUIT TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. AFC CABLE SYSTEMS INC. 3. FILL, VOID OR CAVITY MATERIAL* - CAULK - CAULK FILL MATERIAL FORCED INTO ANNULAR SPACE AROUND ENTIRE CIRCUMFERENCE OF THROUGH PENETRATING PRODUCT TO COMPLETELY FILL OPENING IN GYPSUM WALLBOARD LAYERS ON EACH SIDE OF THE WALL ASSSEMBLY. A MIN 5/8 IN. THICKNESS OF CAULK IS REQUIRED FOR THE 1 HR. F RATING. A MIN. 1-1/4 IN THICKNESS OF CAULK IS REQUIRED FOR 2 F RATING. MINNESOTA MINING & MFG CO - CP 25WB+ *BEARING THE UL CLASSIFICATION MARKING 9 FLEXIBLE CONDUIT PENETRATION DETAIL N.T.S. NEW 2 LAYERS 5/8" TYPE 'X' GYP. BD. OVER EXISTING METAL FRAMING MAM•AMlift, I NEW ACOUSTICAL CEILING EXISTING STUD FRAMING NEW 5/8" TYPE 'X' GYP. BD. ONE SIDE OVER 3-5/8" 25 GA. MTL STUDS @ 16" O.C. NEW 4" VINYL COVE BASE NEW SLAB—� \ 4 WALL SECTION SCALE 1/2" = 1'-0" 2503WSF-2.DWG 1. WALL ASSEMBLY -THE 1 OR 2 HR FIRE RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY SHALL BE CON- STRUCTED OF THE MATERIALS AND IN THE MANNER DESCRIBED IN THE INDIVIDUAL U300 OR U400 SERIES WALL OR PARTITION DESIGN IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES: A. STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. LUMBER SPACED 16 IN. O.C. WITH NOM 2 BY 4 IN. LUMBER END PLATES AND CROSS BRACES. STEEL STUDS TO BE MIN. 3-5/8 IN. WIDE BY 1-3/8 IN. DEEP CHANNELS SPACED MAX. 24 IN. O.C. B_ WALLBOARD, GYPSUM* - NOM 5/8 IN. THICK, 4 FT. WIDE WITH SQUARE OR TAPERED EDGES. THE GYPSUM WALLBOARD TYPE, NUMBER OF LAYERS, AND SHEET ORIENTATION SHALL BE AS SPECIFIED IN THE INDNIDUAL WALL OR PARTITION DESIGN. DIAM OF CIRCULAR CUT THROUGH GYPSUM WALL- BOARD ON EACH SIDE OF WALL ASSEMBLY TO BE MIN. 0 IN. (POINT CONTACT) TO MAX. 1 IN. LARGER THAN OUTSIDE DIAM OF FLEXIBLE METAL CONDUIT (ITEM 2) INSTALLED IN THROUGH OPEN- ING. SIDE EDGE OF CIRCULAR OPENING TO BE MIN. 3 IN. FROM NEAREST STUD IN WALL CAVITY. C. FASTENERS - WHEN WOOD STUD FRAMING IS EMPLOYED, GYPSUM WALLBOARD ATTACHED TO STUDS WITH CEMENT COATED NAILS AS SPECIFIED IN THE INDIVIDUAL WALL OR PARTITION DESIGN. WHEN STEEL CHANNEL STUD FRAMING IS EMPLOYED, GYPSUM WALLBOARD ATTACHED TO STUDS WITH TYPE S SELF -DRILLING, SELF -TAPPING BULGE -HEAD STEEL SCREWS AS SPECIFIED IN THE INDIVIDUAL WALL OR PARTITION DESIGN. 2. THROUGH PENETRATING PRODUCT* - FLEXIBLE METAL CONDUIT - NOM 4 IN. DIM (OR SMALLER) ALUMINUM OR STEEL FLEXIBLE METAL CONDUIT+. MAX. ONE FLEXIBLE METAL CONDUIT TO BE INSTALLED NEAR CENTER OF CIRCULAR OPENING IN GYPSUM WALLBOARD. FLEXIBLE METAL CONDUIT TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY, AFC CABLE SYSTEMS INC. 3. FILL, VOID OR CAVITY MATERIAL* - CAULK - CAULK FILL MATERIAL FORCED INTO ANNULAR SPACE AROUND ENTIRE CIRCUMFERENCE OF THROUGH PENETRATING PRODUCT TO COMPLETELY FILL OPENING IN GYPSUM WALLBOARD LAYERS ON EACH SIDE OF THE WALL ASSEMBLY. A MIN. 5/8 IN. THICKNESS OF CAULK IS REQUIRED FOR THE 1 HR. F RATING. A MIN. 1-1/4 IN THICKNESS OF CAULK IS REQUIRED FOR 2 F RATING. MINNESOTA MINING & MFG. CO - CP 25WB+ *BEARING THE UL CLASSIFICATION MARKING 4. MIN. 26 GA_ METAL STUD SCREWED TO FACE OF FIRE WALL THROUGH THE GYP. BD. FINISH INTO THE METAL STUDS FROM STUD TO STUD AT PENETRATION ONLY. 5. CABLE STRAP ATTACHED TO METAL STUD SUPPORT. g PIPE PENETRATION DETAIL N.T.S. ATTACHED WITH POWER ACTUATED FASTNERS EXISTING ROOF DECK rd 3 5/8" (25 GA_) METAL STUD BRACE ® 4'-0" SALES STOCK ROOM NEW ACOUSTICAL CEILING NEW ACOUSTICAL CEILING NEW 5/8" TYPE 'X' GYP. BD. BOTH SIDES OVER 3-5/8" 25 GA. MTL STUDS @ 16" O.C_ NEW 4" VINYL COVE BASE — NEW SLAB 3 WALSECTION SCALE 1/2"L = 1'-0" 2503WSF-2.DWG SYSTEM NO. W-L-1001 (FORMERLY SYSTEM NO. 147) F RATINGS-1,2,3 AND 4 HR (SEE ITEMS 2 AND 3) T RATINGS-0,1,2,3 AND 4 HR (SEE ITEM 3) L RATING AT AMBIENT -LESS THAN 1 CFM/SQ. FT. L RATING AT 400 F-LESS THAN 1 CFM/SQ. FT. SECTION A -A 1. WALL ASSEMBLY -THE 1,2,3 OR 4 HR FIRE -RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER DESCRIBED IN THE INDIVIDUAL U300 OR U400 SERIES WALL OR PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES: A. STUDS -WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS (MAX 2 H FIRE RATED ASSEMBLIES) OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. LUMBER SPACED 16 IN. O.C. WITH NOM 2 BY 4 IN. LUMBER END PLATES AND CROSS BRACES. STEEL STUDS TO BE MIN. 3-5/8 IN. WIDE BY 1-3/8 IN. DEEP CHANNELS SPACED MAX 24 IN. O.C. B. WALLBOARD, GYPSUM*-NOM 1/2 OR 5/8 IN. THICK, 4 FT. WIDE WITH SQUARE OR TAPERED EDGES. THE GYPSUM WALLBOARD TYPE, THICKNESS, NUMBER OF LAYERS, FASTENER TYPE AND SHEET ORIENTA- ATION SHALL BE: AS SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES DESIGN IN THE UL FIRE RES- ISTANCE DIRECTORY. MAX DIAM OF OPENING IS 13-1/2 IN. 2. PIPE OR CONDUIT-NOM 12 IN. DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE, NOM 12 IN. DIAM (OR SMALLER) SERVICE WEIGHT (OR HEAVIER) CAST IRON SOIL PIPE, NOM 12 IN. DIAM (OR SMALLER) CLASS 50 (OR HEAVIER) DUCTILE IRON PRESSURE PIPE, NOM 6 IN. DIAM (OR SMALLER) STEEL CONDUIT, NOM 4 IN. DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING, NOM 6 IN, DIAM OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING OR NOM 1 IN. DIAM (OR SMALLER) FLEXIBLE STEEL CONDUIT. WHEN COPPER PIPE IS USED, MAX F RATING OF FIRESTOP SYSTEM (ITEM 3) IS 2 H. STEEL PIPES OR CONDUITS LARGER THAN NOM 4 IN. DIAM MAY ONLY BE USED IN WALLS CONSTRUCTED USING STEEL CHANNEL STUDS. A MAX OF ONE PIPE OR CONDUIT IS PERMITTED IN THE FIRESTOP SYSTEM. PIPE OR CONDUIT TO BE INSTALLED NEAR CENTER OF STUD CAVITY WIDTH AND TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. 3. FILL, VOID OR CAVITY MATERIAL* - CAULK- CAULK FILL MATERIAL INSTALLED TO COMPLETELY FILL ANNULAR SPACE BETWEEN PIPE OR CONDUIT AND GYPSUM WALLBOARD AND WITH A MIN 1/4 IN. DIM. BEAD OF CAULK APPLIED TO PERIMETER OF PIPE OR CONDUIT AT ITS EGRESS FROM THE WALL. CAULK INSTALLED SYMMETRICALLY ON, BOTH SIDES OF WALL ASSEMBLY. THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS DEPENDENT UPON THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED. AS SHOWN IN THE F01_LOWING TABLE. THE HOURLY T RATING OF THE FIRESTOP SYSTEM IS '?EPENDENT !UPON THE TYPE OR SIZE OF THE PIPE OR CONDUIT AND THE HOURLY FIRE RATING OF THE WALL ASSEYSLY IN WHICH IT IS INSTALLED, AS TABULATED BELOW: MAX PIPE ANNULAR F T OR CONDUIT SPACE, RATING, RATING, DIAM, IN IN HR HR 1 0 TO 3/16 1 OR 2 0+, 1 OR 2 1 1/4 TO 1/2 3 OR 4 3 OR 4 4 0 TO 1 1 OR 2 0 4 0 TO 1-1 24 1 OR 2 6 1 4 TO 1/2 3 OR 4 0 12 3/16 TO 3/8 1 OR 2 0 +WHEN COPPER PIPE IS USED, T RATING IS 0 H. TTHOETMIN THICKNESS IN. ANNULAR SPACE APPLIES ONLY WHEN IE5B+ CAULK IS USED AND 0nLY N KNESS OF HE GYPSUM WALLBOARD IS5/8TN.FOR 1HRRATED WALLS AND 1- /4IN FOR 2 HR RATED WALLS. MINNESOTA MINING & MFG. CO. - CP 25WB+. *BEARING THE UL CLASSIFICATION MARKING __T EXISTING METAL STUD FRAMING TO REMAIN I ? NEW 5/8" TYPE �, ! 'X' GYP. BD NEW 5/8" TYPE 'X' GYP. BD. BOTH SIDEL25G%. r ' 3-5MTL. 16" O.C. NEW 12" 16GA. DOUBLE STUD HEADER .145 P.A.F. @ I 12" O.C. I I I I I I I REMOVE 1 I I I EXISTING WALL ---- I I I I I I NEW FRAME LESS I I STOREFRONT GLAZING 1 1 SYSTEM LEASE LINE ! I I I I I I I I I I I I I I I 1 I I I I .145 P.A.F. @ 1 1 � I 12" O.C. NEW 3-5/8" 20GA. MTL. STUD BRACE @ 4'-0" O.C. NEW ACOUSTICAL CEILING 2 WALL SECTION SCALE 1 /2" = 1'-0' 2503WSF.DWG PIPE PENETRATION DETAIL N.T.S_ EXISTING STRUCTURE TO REMAIN NEW 5/8" TYPE 'X' GYP. BD NEW ACOUSTICAL CEILING ob 10'-0" EXISTING METAL STUD FRAMING TO REMAIN .145 P.A.F. @ I 1 I I 12" O.C. I I I I 1 I I 1 � I REMOVE EXISTING WALL --1 1 I � I � I I I I I NEW FRAME LESS STOREFRONT GLAZING SYSTEM i 1 LEASE LINE .145 P.A.F. @ 12" O.C. 1 WALL SECTION SCALE 1/2- = l'-0" 2503WSF.DWO m m i I I Z O N Q I j 0 Z N V) P L 0 C O O U r P Y O O U 0 q r v a rQl w Q 0 CD Lo L I L w I� � Z 3v'io n ¢ E�CD wwN CL U W .o o U, E 0 LLJ �' rn V U) CONTRACTOR -SHALL" VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECT a OF ANY DIMENSIONAL ERRORS, OMISSIONS OR DISCREPANCIES a BEFORE BEGINING OR FABRICATING ANY WORK. N DO NOT SCALE DRAWINGS. w �o 0 P Q 0 U U L U 'o v • U 0 Jd ° Q � o r! W V O cry �Q az� cn �C wl <o�� ® Q o � < WO 0--1 (n J �- Z �LA-i E-I Za V) C < W L a w � W CL P FIR W Z �I SI 04 o �; o 0! fl DRAWN BJ CHECKED J RJJ DATE 09/02/03 SCALE AS NOTED PROJECT NO. H32503 FILE NAME 2503A3U SHEET A®3 6 EXISTING FIREWALL DESIGN N.T.S. 5 WALL SECTION SCALE 1/2" = l'-0" 2503WSF-2.DWG 15000 - GENERAL CONDITIONS FOR PLUMBING WORK 1.1 Materials and workmanship A. Products and materials shalt meet or exceed the quality or requirements specified or shown on the drawings. B. Provide products and materials, which the manufacturer has certified as appropriate to the applications shown on the drawings and specifications, C. Provide products and _materials, which are supported by convenient, parts availability and servicing. D. Workmanship shall be in all respects of the highest quality and all construction shalt be done according to the best practice of the trade, All systems shall be made complete and operational In first class working order. Furnish all necessary labor and materials to construct a complete system. 1,2 Obtain all permits and inspections required by law for the completion of the work, Cost of the required permits and inspections shall be paid by the contractor, The Contractor shall obtain and pay for all Certificates of Approval, which must be obtained prior to final acceptance of the job, All materials and labor furnished by the Contractor shalt be in strict accordance with the rules and regulations of the state and municipality, utility companies, Florida Building Code - 2001, National Electric Code (NEC) and the National Fire Protection Association (NFPA). 1.3 Provide the owner with the following prior to final application for payment: A, Parts list for each piece of equipment. B, One bound set of approved shop drawings. C, One bound set of operating instructions and maintenance schedules for each piece of equipment, D. Copies of all warranties for each piece of equipment. 14 Guarantees and warranties A, Guarantee all labor and material furnished for a period of one year extending from the time of final acceptance of the building, The guarantee shall cover the repair or replacement without additional cost to the owner for any defective material or faulty workmanship. B, Provide warranties for each piece of major equipment, Warranties shall be Included with the owner's final documents, 15100 - PLUMBING 1.1 General A. Work shall include but not be limited to the following: Provide all labor, materials, services, equipment and appliances required for the fabrication and installation of the plumbing system, as Indicated on the design drawings and as outlined in these specifications, B. Equipment and design of systems indicated on the design drawings and within these specifications shall be considered as 'specified standard' of quality. Substitutions shall be of equal quality. C. The entire system and all components listed herein shall meet all state, county and local codes and ordinances in every respect, The contractor shall obtain all required permits, inspections and pay all fees, D. All equipment, etc, shall be new unless otherwise noted, and as specified free of defects as shown on the drawings and as Indicated in these specifications. All electrical powered equipment shall be U.L. or E,T,L, Listed, E. All materials shall be fabricated and Installed In a neat and professional manner with the coordination of all involved trades to avoid interferences and delay due to lack of coordination. No allowances will be made for rework due to coordination difficulties or interferences between involved trades, 1.2 Submittals A. Submit for engineer's approval, shop drawings, and manufacturer's data for all new equipment and fixtures prior to purchase and or fabrication. Shop drawings for equipment requiring electric power or control wiring connections shall include complete wiring diagrams, B. The contractor shall provide the engineer two (2) sets of complete plumbing as -built drawings at the time of substantial completion, As-builts shall be provided on reproducible vellum and AutoCAD drawing files (if possible.]. As -built drawings shall consist of an accurate 'as -built' record of the Installed work, Project will not be complete until accurate as -bunts are delivered, C. Provide complete maintenance manuals (3 required) on all new equipment, Organize operating and maintenance data into suitable sets of manageable size, Bind properly indexed data in individual, heavy-duty, 2-Inch, 3-ring vinyl -covered binders with pocket folders for folded sheet Information. Mark appropriate identification on front and spine of each binder, Include the following type of Information, The information will be turned over to the owner at time of substantial completion: 1. Operating and maintenance Instructions 2, Spare parts list 3. Copies of warranties 4. Wiring diagrams 5. Inspection reports and approvals 6. Shop drawings o.nd product data 1.3 Access panel A, Contractor shall provide hinged access doors (min, 12'x12') for valves, etc, where floors, walls and telling must be penetrated to access mechanical systems, Finish shall be coordinated through the architect to match surrounding finishes, 1.4 Cleaning, testing and adjusting A. The contractor, at his expense, shall clean, repair, adjust, check, A. balance, and place In service the various systems herein specified with their respective equipment, accessories and piping, The contractor shall furnish all labor, materials, equipment, and tools required to perform tests required by these specifications and by the governing authorities. B, No work shall be covered or concealed until properly Inspected B. and tested, C. All domestic water piping systems shall be tested for absolute C, tightness by subjecting the system to a hydrostatic pressure of 150 PSI gauge or 50 PSI over working pressure, whichever is greater for a period of not less than eight (8) hours. All leaks shall be repaired and the hydrostatic test reapplied until, for an eight (8) hour period, no leaks can be found while the system is subject to the test pressure, Soil pipe and condensate drains shall be tested by temporarily plugging all outlets and filling the system with water to the level of the highest vent stack, The system must be Inspected and all leaks repaired and the test repeated until the water level does not decrease for a period of 24 hours. 1bL41110I TO SYSTEM REFER TO PLANS FOR SIZES I— C11-1> WATER EXPANSION TANKJ HEATER ET-1 SEE 2" SCHEDULE WATER HEATER DRAIN PAN 24" X 24" X 2" HIGH (24 GA. GALV. STEEL) ALL JOINTS WATERTIGHT - HEAT TRAP IN ACCORDANCE WITH ENERGY CODE DIELECTRIC UNION (TYP.) P & T RELIEF PIPING FULL SIZE 4f TO MOP SINK. TERMINATE 6" ABOVE SINK, MOUNT WATER HEATER ON WALL MOUNTING BRACKET 8'-0" A.F.F. /� ROUTE THE WATER HEATER DRAIN PAN / DRAIN LINE FULL SIZE TO MOP BASIN, `_- 1 " DRAIN CONNECTION TO PAN SHALL BE MADE WATER TIGHT AND FLUSH WITH BOTTOM OF PAN. NOT TO SCALE I #AT�'R ffT4 PAIN I0ETT4IL I PDO12L 1.5 Hangers and supports A. Provide all necessary, pipe supports, hangers, rods, clamps and attachments to properly install and support piping and equipment from the building structure. B. Provide any angle iron or unistrut and suspension rods required to install equipment and piping. 1.6 Water supply system A. Extend water service as indicated on design drawings, Provide shock absorbers and vacuum breakers where required, B. Pipe and fittings above ground - type L hard copper and wrought copper fittings. Pipe and fittings below ground - type K, soft copper, Valves - ball valves - all bronze, rising stem, double wedge taper seat, 125 PSIG pressure, C. Insulation shall be fire rated for use in return air plenum. 1.7 Connections to miscellaneous equipment A. Rough -in and connect water, waste, and vent to complete the installation of equipment listed on the drawings. B. Plumbing fixtures shall be provided complete as shown on the drawings with all required supply, waste, soil, and vent connections, together with all fittings, supports, fastening devices, cocks, valves, and traps, C. All fixtures shalt have stop valves on all water connections, All exposed metal trim on all fixtures shall be polished chromium plated, All exposed pipes extending from wall shall have chromium plated brass escutcheon mounted against wall. Exposed PVC piping and p-traps are unacceptable, D. The plumbing fixtures shall be roughed -in accordance with manufacturer's 'rough -in information', Provisions for mounting wall fixtures shall be made while the wall is being built, 1,8 Drainage system A, Pipe slope: 1. 2-112 inch diameter and less shall be installed with a fall of not less than 1/4 inch per foot. 2. 3 Inch diameter or larger shall be installed with a fall not less 2, Than 1/8 inch per foot, B. Pipe and fittings: 1. Drain, waste and vent piping located in fire rated wall assemblies and return air plenums shall be service -weight cast iron with no/hub or bell and spigot fittings. 2. Provide cleanouts every 75 feet, at changes in direction, at base of down spouts and at base of soil and waste stacks. 1,9 Execution A. All locations of equipment, piping, etc. indicated on the drawings are diagrammatic and shall be Followed as closely as possible to the plans, subject to building construction and interferences with other trades, All work shall be installed to ensure maximum headroom, balanced operation and suitable aesthetic appearance, Contractor is responsible for any field measurements required to provide an approved and functional Installation, B. Not all components required for a complete installation are shown on these drawings. Refer to equipment installation instructions, schedules and applicable codes for additional information, including required connection locations, types and sizes. C. Provide isolation valves and unions at all equipment and as indicated on drawings. A Contractor shall be responsible for furnishing and Installing adequate and proper insulation and moisture -seal in a manner that will permanently prevent the accumulation of any objectionable moisture on the exterior of condensate drain piping, or other parts of the system, The contractor shall correct the cause of any condensation and fully repair, without cost the owner, any damages to building surfaces, furnishings or equipment caused by condensation from this system, for the Full period of the guarantee, E. Perform all work necessary to prepare the structure for the Installation of the work, F. All holes, openings and damaged materials created during construction shall be repaired and finished by experienced workmen, Provide all roof, wall and floor penetrations required to complete installation or work (maintain fire rating of existing structure), All penetrations shall be patched and finished to match surrounding surfaces and finishes. All equipment or pipe penetrations through watt, roof and floors shall be sleeved and seated so as to be water and air tight, END OF SECTION 15100 PLUMBING FIXTURE SCHEDULE REF ITEM MFR & CAT. NO. WASTE TRAP VENT H.W. C.W. L-1 WALL HUNG LAVATORY - ADA: AMERICAN STANDARD 2 1 1/4 1 1/4 1/2 1/2 VITREOUS CHINA, 18" X 15" 0373.027 PERFORATED STRAINER WiTH 1 1/4" McGUIRE 155-WC OFFSET TAILPIECE, CHROME PLATED 3/8" SUPPLY W/ANGLE McGUIRE 158WC STOP & WROT ESCUTCHEON OFFSET, CHROME BRASS P-TRAP, 17 GA. WITH McGUIRE 8902 ESCUTCHEON WAIL MTD. CARRIER W/HANGER PLATE, JOSAM OR ZURN CONCEALED ARMS. FAUCET WITH AERATOR, 4" WRIST BLADES SYMMONS S-90-FR 0.5 GPM FLOW, ON 4" CENTERS MB-1 SERVICE SINK; FIAT MSB-2424 3 3 2 1/2 1/2 ONE-PIECE CONSTRUCTION, 24" X 24" X 10 I FLOOR MOUNTED TYPE. FAUCET WITH PAIL HOOK AND HOSE END, FIAT 830-AA VACUUM BREAKER, INTEGRAL STOPS HOSE AND HOSE BRACKET FIAT 832-AA MOP HANGAR, 24' X 3", 18 GA. FIAT 889-CC VINYL BUMPER GUARD FIAT E-77-AA SILICONE SEALANT FIAT 833-AA WC-1 WATER CLOSET - ADA; AMERICAN STANDARD 3 INT. 2 - 1/2 VITREOUS CHINA, FLUSH TANK, SIPHON 2108.408 JET, ELONGATED BOWL, 12" ROUGHING, FLOOR MOUNTED, WATER SAVER TYPE, SEAT 19' A.F.F., WHITE SOLID PLASTIC SEAT, OPEN FRONT CHECK HINGE, OLSONITE 95 CHROME PLATED 3/8" SUPPLY W/ANGLE STOP AND WROT. ESCUT. McGUIRE 166 PLUr RlyVG T19UIPffEyVT ,S'CLIL'I'ULE REF. ITEM MANUFACTURER & CAT. NO, REMARKS EWC-1 ELECTRIC WATER COOLER ELKAY EHFA-8 MOUNT W/BUBBLER 36" A.F.F. FCO FLOOR CLEANOUT JOSAM 56064-14 W/CARPET COVER OR APPROPRIATE COVER WH-1 ELECTRIC WATER HEATER LOCHINVAR ESA03OKK 30 GAL, 450OW, 208V, 1 PH K.3 - J.8 - K.3 - J.8 - PAR TIA L SAKI TAR Y PLAN NOTE: THE SPACE ABOVE THE CEILING IS A SCALE; 3/16" = 1'-0" RETURN AIR PLENUM_ ALL PIPING SHALL BE CAST IRON OR COPPER. 0 4 8 10 (FEET) 20 GRAPHIC SCALE ,T, CONNECT TO EXIST. VENT \ `---EXIST. 4" VENT I \ � I � ',$�EXIST. 4' SAN.NEW \\ FCO CONNECT TO \ EXIST. SAN. "4-2' VENT 4 \ FCO \ A r--1-1/4 2 �N,\ 1-1/4� EWG-1 IN � 2� 5� WC-1 SA NI T A 1Y RISER DIAGRAM NOT TO SCALE PARTIAL WATER PLAN )/� 0 4 8 10 (FEET) 20 GRAPHIC SCALE 1/2 i ................ i I /2 MB-1 1 1 _l 1/2 WC-1 WATER RISER DIAGRAM NOT TO SCALE 3/4 NATIONAL ENGINEERING CORP. Consulting .engineers n Cori. or Auth. 1 W3 220 Live Oaks Boulevard, Casselberry, FL 32707 407/539-3400 ia=ev X. fowler, Jr., PS f 4M71 03032 ©2003 No6orwl En4m ing Corp., AN Rights Reserved 9-5-03 m rn 0 VN a' W a Z •- N Q � r E--+ O � w n o rn Lo O V 1 J O n O Lo n In co LLJo V) F= °O n OO Z V) C> o Z CD N V) � x W U 1!� 1.4 CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECT OF' ANY DIMENSIONAL ERRORS, OMISSIONS OR DISCREPANCIES BEFORE BEGINING OR FABRICATING ANY WORK. DO NOT SCALE DRAWINGS. Q v)77, Q Q E-4 � J I .i..l Cl— LiJ o LEI a �® aZLL Z U (DC) o �� QF- cr- Q C) a CD Q J J aW � V) O � f Z V a) .p a DRAWN BAV CHECKED JMF DATE 09/02/03 SCALE AS NOTED PROJECT NO. H32503 FILE NAME 3032—Pl SHEET DIVISION 15000 - MECHANICAL 15000 - GENERAL CONDITIONS FOR MECHANICAL WORK 1.1 Materials and workmanship A. Products and materials shall meet or exceed the quality or requirements specified or shown on the drawings. B. Provide products and materials, which the manufacturer has certified as appropriate to the applications shown on the drawings and specifications. C. Provide products and materials, which are supported by convenient, parts availability and servicing. D. Workmanship shall be in all respects of the highest quality and all construction shall be done according to the best practice of the trade. All systems shall be made complete and operational in first class working order. Furnish all necessary labor and materials to construct a complete system. 1.2 Obtain all permits and inspections required by law for the completion of the work. Cost of the required permits and inspections shall be paid by the contractor. The Contractor shall obtain and pay for all Certificates of Approval, which must be obtained prior to final acceptance of the job. All materials and labor furnished by the Contractor shall be in strict accordance with the rules and regulations of the state and municipality, utility companies, Florida Building Code - 2001, National Electric Code (NEC) and the National Fire Protection Association (NFPA). 1.3 Provide the owner with the following prior to final application for payment: A. Parts list for each piece of equipment. B. One bound set of approved shop drawings. C. One bound set of operating instructions and maintenance schedules for each piece of equipment. D. Copies of all warranties for each piece of equipment. 1.4 Guarantees and warranties A. Guarantee all labor and material furnished for a period of one year extending from the time of final acceptance of the building. The guarantee shall cover the repair or replacement without additional cost to the owner for any defective material or faulty workmanship. B. Provide warranties for each piece of major equipment. Warranties shall be included with the owner's final documents. 15300 - HEATING, VENTILATING AND AIR-CONDITIONING 1.1 General A. Provide all labor, materials, services, equipment, and appliances required for the fabrication and installation of mechanical systems including heating, ventilating, air-conditioning, and various systems as indicated on the design drawings and as outlined in these specifications. B. Equipment and design of systems indicated on the design drawings and within these specifications shall be considered as 'specified standard' of quality. Substitutions shall be of equal quality. C. The entire system and all components listed herein shall meet all state, county, and local codes and ordinances in every respect. The contractor shall obtain all required permits, inspections and pay all fees. D. All equipment, etc. Shall be new unless otherwise specified, free of defects as shown on the drawings, and as indicated in these specifications. E. All materials shall be fabricated and installed in a neat and professional manner with the coordination of all involve trades to avoid interferences and delay due to lack of coordination. No allowances will be made for rework due to coordination difficulties or interferences between involved trades. 1.2 Submittals A. Submit for engineer's approval, shop drawings, and manufacturer's data for all new equipment and Fixtures prior to purchase and/or fabrication. Submittal package for HVAC equipment shall also include Qualifications and certifications of proposed test and balance subcontractor. HVAC submittals will not be reviewed without test and balance documentation. Qualifications of multiple test and balance Contractors is acceptable (to accomplish competitive bidding of work). Shop drawings for equipment requiring electric power or control wiring connections, shall include complete wiring diagrams. B. Contractor shall provide the engineer two (2) sets of complete HVAC as -built drawings at the time of Substantial completion. As-builts shall be provided on reproducible vellum and AutoCAD drawing files (if possible). As -built drawings shall consist of accurate "as -built" records of the installed work The project will not be complete until accurate as-builts are delivered. C. Maintenance manuals Provide complete maintenance manuals (3 required) on all new equipment. Organize operating and Maintenance data into suitable sets of manageable size. Bind properly indexed data in individual, heavy- Duty, 2-inch, 3-ring vinyl -covered binders with pocket folders for folded sheet information. Mark appropriate identification on front and spine of each binder. Include the following types of information. The information will be turned over to the owner at time of substantial completion: 1. Operating and maintenance instructions 2. Spare parts list 3. Copies of warranties 4. Wiring diagrams 5. Inspection reports and approvals 6. Shop drawings and product data 1.3 Training services A. Thoroughly instruct the owner's personnel during normal working hours on start-up and shut -down procedures, Troubleshooting procedures, servicing and preventative maintenance schedules and procedures. Review With the owner's personnel the data contained in the operating and maintenance manuals. Schedule the Training with the owner. Provide at least 7-days prior notice to architect/engineer. 1.4 System identification A. Provide identification labels on or near each piece of major equipment and each operational device and Disconnect. The labels shall be constructed of engraved plastic laminate sign or plastic equipment Marker permanently secured to equipment. The lettering shall be a minimum of 1/2 inch high for equipment Name and 3/8 inch for equipment information. 1.5 Hangers and supports A. Provide all necessary ductwork, pipe supports, hanger rods, clamps and attachments to properly install and support ductwork, piping and equipment from the building structure. Provide any angle iron or unistrut and suspension rods required to install equipment, piping and Ductwork. B. All supports exposed to outdoors shall be cleaned, primed and painted to prevent rusting. Finish color as selected by owner. C. The use of baling wire or perforated metal strapping is not acceptable for supports. 1.7 Air distribution equipment A. Furnish supply air diffusers and return air grilles as schedules on the design drawings. Metal-aire or Price may be substituted as an equal. B. Grilles, registers, and diffusers shall be furnished as scheduled on the design drawings and shall be all B. Steel construction. Air distribution shall not exceed NC-30 noise criteria as defined in the latest ASHRAE guide. 1.8 Ductwork A. Materials: galvanized steel of gauges conforming to latest edition of SMACNA standards based on 1" w.ga. pressure unless specifically noted otherwise on the drawings. The galvanized duct coating is to be G-90. All dimensions are inside net free area. B_ Adjustable splitters and dampers shall be installed in every split and branch duct and shall be provided with locking quadrants on exposed or in accessible areas of the duct for ease or operation. Elbows or changes in duct direction greater than 45 degrees shall be fitted with air turns consisting of Curved airfoil blades or vanes, which will permit the air to make abrupt turns without appreciable Turbulence. C. Flexible ductwork shall be acoustical low-pressure type with interior liner, metal helix, fiberglass Insulation with an R-value of 6.0 or greater, and copolymer seamless outside sleeve. The entire flexible Duct assembly shall be listed in accordance with UL-181 class 1 air duct material. The maximum length of any flex duct shall be 8'-0". Flexible ductwork shall meet the Florida model energy efficiency code. 1.9 Fire safety controls A. Install smoke detector furnished by Division 16 in supply and return air ducts. Detector shall shut unit off when activated. B. Provide fire stat in return air of unit. Fire stat to shut unit off when activated. 2.0 Vibration isolation A. All blower units and vibrating type equipment shall be properly fitted with Mason Industries vibration Isolation equipment sized in accordance with equipment weight and duty. B. Provide flexible connectors at all supply and return connections to air conditioning equipment consisting of Heavy canvas or neoprene fabric with airtight seams and connections to the equipment. 2.2 Access doors A. Furnish in ductwork as indicated and wherever necessary for proper access to all instruments, Controls, fire dampers motorized dampers and equipment and for convenient inspection, maintenance and Replacement of some, Size to be ample for usage. Openings to be reinforced on all sides with material or Ductwork in which doors are installed. B. Hardware - use vent lok hardware throughout. All doors to be hinged with brass pin hinges and with Quick opening latches as follows: 1. Reach -in doors to be 18" high. 2. Two (2) #150 hinges w/one #90 latch. C. Access doors (hard surfaces) Contractor shall provide hinged access doors (min. 12"x12' for dampers, valves, etc. Where floors, walls, and ceilings must be penetrated to access mechanical systems. Finish shall be coordinated through the Architect or owner's representative to match surrounding finishes. Fire rated access doors in fire Rated walls or ceilings shall bear a U.L. Label for fire rating requirement. 2.3 Insulation A. Shall be as manufactured by Owen -Corning, Manville, Pittsburgh Corning, Armstrong, or approved equal. Insulation sundries and adhesives shall be manufactured by Benjamin Foster, Childers, Vimasco, or Approved equal. B. Insulate all sheet metal ductwork except exhaust ductwork externally with 2" thick (R-6 minimum) Manville R series microlite type-100 insulation or approved equal. Insulation to have fsk facing and UL fire hazard Classification of: flames spread 25, smoke developed 50, fuel contributed 50. Install per SMACNA, Florida Model energy efficiency code and manufacturer's recommendations. C. Contractor shall be responsible for furnishing and installing adequate and proper insulation and Moisture -seal in a manner that will permanently prevent the accumulation of any objectionable moisture On the exterior of air-conditioning units, refrigerant piping, condensate drain piping, air ducts or other Parts of the system. Contractor shall correct the cause of any condensation and fully repair, without Cost to the owner, any damages to building surfaces, furnishings or equipment caused by condensation from this system, for the full period of the guarantee. 2.4 Testing A. Adjust the air-conditioning systems, ventilating systems, fans, etc. To deliver not less than the required Air quantity with quantities in excess to be subject to the approval of the engineer if found not have Objectionable effects such as noise, drafts, or motor overloads. B. Prior approval by the engineer of testing and balancing contractor is required. See the shop drawings and submittal section. Test and balance reports by non -approved contractors will be rejected. C. This contractor shall provide three (3) copies of a test and balance report to the engineer at time of Substantial completion inspection. The test and balance report shall be prepared by a contractor Certified by Associated Air Balance Council, National Environmental Balancing Bureau or a Professional Engineer registered in the state of Florida. D. The test and balance report shall be typewritten and contain the following data: 1. Date, time, weather, when test taken. 2. Air capacities at each unit including outside air. (Entering and leaving db/wb) 3. Static pressure through units and unit components. 4. Motor operating voltage and amperage. 5. Drive types, sizes and speed range. 6. Identification of all air terminal devices with design cfm and actual cfm. E. Additionally, systems drawings clearly marked to identify location of equipment and air devices tested shall be provided along with the written test and balance report. 2.5 Execution A. All locations of equipment, ductwork, piping, etc. Indicated on the drawings are diagrammatic and shall be Followed as closely as possible to the plans subject to building construction and interferences with Other trades. All work shall be installed to ensure maximum headroom, balanced operation and suitable Aesthetic appearance. Contractor is responsible for any field measurements required to provide an Approved and functional installation. B. Not all components required for a complete installation are shown on these drawings. Refer to Equipment installation instructions, schedules and applicable codes for additional information, including required connection locations, types and sizes. C_ Contractor shall be responsible for furnishing and installing adequate and proper insulation and Moisture -seal in a manner that will permanently prevent the accumulation of any objectionable moisture On the exterior of air-conditioning units, refrigerant piping, condensate drain piping, air ducts or other Parts of the system. Contractor shall correct the cause of any condensation and fully repair, without cost to the owner, any damages to building surfaces, furnishings or equipment caused by condensation from this System for the full period of the guarantee. D. All penetrations shall be patched and finished to match surrounding surfaces and finishes. All equipment or pipe penetrations through walls, roofs and floors shall be sleeved and sealed so as to be water and airtight. E. Cleaning testing and adjusting: the contractor, at his expense, shall clean, repair, adjust, check, balance, and place in service the various systems herein specified with their respective equipment, accessories and piping_ He shall furnish all labor, materials, equipment, and tools required to perform tests required by these specifications and by the governing authorities. F. No work shall be concealed until properly inspected and tested. END OF SECTION 15300 AIR DISTRIBUTION EQUIPMENT SCHEDULE SYM MANUF. - CAT_ NO. TYPE THROW DIR. NECK FRAME A TITUS - TMS (FULL FACE) CD 4-WAY ON DWGS 24/24 B TITUS - TMS (FULL FACE) CD 4-WAY ON DWGS 12/12 C TITUS - 35ORL RAR N/A 22/22 24/24 LEGEND: CD = CEILING DIFFUSER ER = EXHAUST REGISTER RAR = RETURN AIR REGISTER SWR = SIDEWALL REGISTER OBD = OPPOSED BLADE DAMPER OAL = OUTSIDE AIR LOUVER NOTES: 1. PROVIDE ALL CEILING DEVICES WITH PROPER FRAME STYLE TO MATCH CEILING TYPE AS CALLED FOR BY ARCHITECT. 2. ALL DEVICES SHALL BE PROVIDED WITH FINISH TO MATCH CEILING OR WALL (USUALLY WHITE). MECHANICAL CONTRACTOR SHALL COORDINATE FINISHES AS CALLED OUT ON ARCHITECTURAL DRAWINGS. 3. ALL AIR DIFFUSERS SHALL BE 4-WAY THROW UNLESS NOTED OTHERWISE OR SHOWN ON PLANS WITH DIRECTIONAL ARROWS. 4. PROVIDE OPPOSED BLADE DAMPERS DALY WHERE INDICATED ON SCHEDULE. VA V BOX SCHEDULE REMARKS BASIS OF DESIGN - ENVIRO-TEC MODEL # SDR MARK SIZE MAX CFM MIN CFM VAV-1 12 1680 350 LAY IN LAY IN LAY IN, OBD VAV-2 14 2520 500 VAV-3 10 1040 200 NOTES: 1. ALL VAV BOXES SHALL BE PROVIDED WITH CONTROLLERS WHICH ARE COMPATIBLE WITH JOHNSON CONTROLS 'METASYS' ENERGY MANAGEMENT SYSTEM. 2. TERMINAL UNIT MANUFACTURER SHALL MOUNT, WIRE, AND/OR PIPE ALL TERMINAL UNIT CONTROLS, INCLUDING DAMPER ACTUATOR AND TERMINAL UNIT CONTROLLER FURNISHED BY THE CONTROL CONTRACTOR AND PER THE MANUFACTURER'S INSTRUCTIONS. THE TERMINAL UNIT MANUFACTURER SHALL FURNISH ALL TRANSFORMERS, RELAYS, AIRFLOW RINGS, AND ENCLOSURES. DAMPER ACTUATORS SHALL BE MOUNTED TO DAMPER SHAFTS AND FACTORY TESTED TO ASSURE PROPER ACTUATOR AND DAMPER POSITION IN THE FULL OPEN AND CLOSED POSITIONS. VENTILATION EQUIPMENT SCHEDULE MARK EF-1 AIR FLOW ( CFM) 95 EXTERNAL STATIC PRESS. ( IN.WTR.) 0.15 TYPE CENTRIFUGAL MOUNTING CEILING FAN DRIVE DIRECT RPM 1309 HP OR WATTS 55 WATTS VOLT/O 120/1 MOTOR RPM 1309 CONTROL TIME DELAY SWITCH AREA SERVED TOILET MANUFACTURER COOK MODEL # GC-140 APPLICABLE NOTES ALL NOTES: 1. PROVIDE BACKDRAFT DAMPER_ 2. PROVIDE INTEGRAL DISCONNECT SWITCH. 3. FAN WILL BE CONTROLLED BY TIME DELAY SWITCH FURNISHED AND WIRED BY ELECTRICAL CONTRACTOR. 4. PROVIDE FAN SPEED CONTROLLER. NATIONAL ENGINEERING CORD, Consulting Engineers A cert of Born. / 6= 220 Live Oaks Boulevard, Casselberry, FL 32707 407 539-3400 A=cs K Porkr, Ar., PS / 4WI 03032©2M National Engineering Corp.. NI Nghts Reserved 9-5-03 rm>- N z 0 �_ �i o; w a 0 0 z LILL) E4 O w o M - O I % it �� J U-) 0 fLn ` �J ¢ o Lo 00 � 7O w�L-LJ ()0 �1 Q N U N _\i CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECT OF ANY DIMENSIONAL ERRORS, OMISSIONS OR DISCREPANCIES BEFORE BEGINING OR FABRICATING ANY WORK. DO NOT SCALE DRAWINGS. O LL. N� P�4 v) LLI (DW C)V) ® Q z LL_ z LEI O UU ry Q® f a_ LA 0 P� ( n L o �°� a Q w C:) I— Z U a> 0 L 0. DRAWN BAV CHECKED JMF DATE 09/02/03 SCALE AS NOTED PROJECT NO. H32503 FILE NAME 3032-M 1 SHEET M fl"VAC PLAN 5"L L77����� 0 4 8 10 (FEET) 20 GRAPHIC SCALE SUPPLY AIR DUCT WITH 2' EXTERNAL INSULATION ROUND STEEL DUCT WVMANUAL VOLUME DAMPER & 2 INSUL 1" WIDE, 22 GA. SEAL FLEX TO DUCT USING GALVANIZED STEEL GLASS FABRIC & MASTIC HANGER STRAP TO STRUCTURE 2" WIDE GALVANIZED STEEL FLEX DUCT SUPPORT STRAP LLLLLU UL 181, CLASS 1 FLEX DUCT STAINLESS STEEL BAND MAXIMUM LENGTH 5 FEET GALVANIZED STEEL OR PANDUIT STRAP SECURE FLEX DUCT TO DUCT 2" BATT INSULATION WITH FOIL DIFFUSER NECK USING VAPOR BARRIER ON OUTSIDE STAINLESS STEEL CLAMP OR PANDUIT STRAP SELF -TAPPING SHEET SEAL INSULATION TO FLEX DUCT AND CEILING METAL SCREWS DIFFUSER USING GLASS FABRIC & MASTIC DIFFUSER- SEE PLAN AND SCHEDULE FOR TYPE D UCT TO SUPPL Y DIFFUSER CONN. DETAIL DUCT SUPPORT DETAIL NOT TO SCALE MD015C NOT TO SCALE MD018J 5/8" THREADED HANGER ROD (MIN. OF 4 PER UNIT) CONNECT TO STRUCTURE VOLUME DAMPER WITH LOCKING QUADRANT BRANCH DUCT CONICAL TEE CONNECTION MEDIUM PRESSURE SUPPLY DUCT TRANSITION TRUNK VAV BOX >0,T DUCT 6" 45' CHANNEL x SUPPLY AIR FLOW SUPPORT FLEXIBLE CONNECTION LOW PRESSURE RECTANGULAR SUPPLY RETURN AIR FLOW DUCT. GALVANIZED STEEL WITH Z° EXTERNAL INSULATION. BRANCH D UCT VA V BOX NOT TO SCALE CONN. DETAIL MD014A NOT TO SCALE INSTALLATION DETAIL MD034C SUPPORT PER SPECIFICATONS (TYP) T/// BACKDRAFT SAME DIMENSION POWER VENTILATOR DAMPER AS NECK SIZE EXHAUST DUCT MATERIAL SIMILAR TO SUPPLY AIR DUCT j� DUCT SEE SPECIFICATIONS 6" MINIMUM z CEILING CAVITY J L_ PAINT INSIDE OF DUCT CONNECT TO EXIST. FLAT BLACK ON ALL 24' MINIMUM EXHAUST CEILING DUCT BY LANDLORD VISIBLE SURFACES GRILLE RETURN AIR GRILLE OR REGISTER AS SCHEDULED ON DRAWINGS RETURN AIR BOOT DETAIL POWER VENTILATOR DETAIL NOT TO SCALE MD036K NOT TO SCALE MD016G NATIONAL E NGINEERING CORP. Consulting Engineers A Cert of Aulh. # WJ 220 Live Oaks Boulevard, Casselberry, FL 32707 407/539-3400 lames M. Fowler, Jr, Y.A: 145071 03032 @2003 NaWmI Fh4rmdrg Cap.. Al Rights Reserved 9-5-03 11 0 0 a .q s �o E c aT V) 0 V) 0 0 U N C O V 7 0 (Z 0 Q' v n. a ti 3 0 0 0 a Q 0 0 0 L 0 V O 0 r 0 0 T a 0 v 0 z 0 0 n 0 V vi V N L V ur a0i Q N 46 a 0 0 0 U C Vi U L a a c c c a s a `c c �3 z a a r N c c Q 0 C C r z a (n LLJ I I L -A z cv c Q o F .�1 O I� q o U c- o�w Q L O 1 a Q L0 00 o=�00� z OO ��o no v z 0 (Dg � U w N � ~� v_ c U CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECT OF ANY DIMENSIONAL ERRORS, OMISSIONS OR DISCREPANCIES BEFORE BEGINING OR FABRICATING ANY WORK. DO NOT SCALE DRAWINGS. � r 1� Y < C _I L.i.J _ ® L.Li V) Qz� LLJ O U O Q F— rz QO�� O c � Li w�1 O Q J z (� Q � W V) O F_ Z V N O L CL DRAWN BAV CHECKED JMF DATE j 09/02/03 SCALE AS NOTED PROJECT NO_ H32503 FILE NAME 3032—M2 SHEET M 2 DIVISION 16000 - ELECTRICAL SPECIFICATIONS 16100 - ELECTRICAL 1.1 GENERAL A. PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, FEES, AND ELECTRICAL PERMITS AND ALL NECESSARY ITEMS TO INSTALL A COMPLETE ELECTRICAL SYSTEM. B. PROVIDE COMPLETE SYSTEMS, REGARDLESS OF WHETHER EACH INDIVIDUAL COMPONENT IS MENTIONED OR NOT. C. THE WORK SHALL COMPLY WITH THE STANDARDS IN THE LATEST APPLICABLE EDITIONS OF THE FOLLOWING LISTED CODES AND ORDINANCES: 1. NFPA NO, 70 "NATIONAL ELECTRIC CODE". 2- NECA "STANDARD OF INSTALLATION." 3. ELECTRIC UTILITY COMPANY SERVICE STANDARDS. 4. TELEPHONE UTILITY COMPANY SERVICE STANDARDS. 5. CABLE TV UTILITY COMPANY SERVICE STANDARDS. 6- UNDERWRITER'S LABORATORY STANDARDS. 7. OTHER LOCAL CODES, ORDINANCES AND LAWS APPLICABLE TO THE PLACE OF WORK- D. RELATED WORK SPECIFIED ELSEWHERE: 1. REFER TO THE ARCHITECTURAL, STRUCTURAL AND TO THE MECHANICAL DIVISIONS OF THE WORK FOR ELECTRICAL WORK TO BE DONE IN CONJUNCTION WITH THESE DIVISIONS. 2. VERIFY LOCATIONS AND ELECTRICAL REQUIREMENTS OF ALL EQUIPMENT FURNISHED BY THE OWNER OR OTHER TRADES PRIOR TO INSTALLATION OF CONDUIT AND WIRE. E. SUBSTITUTIONS: EQUIPMENT AND DESIGN OF SYSTEMS INDICATED ON THE DESIGN DRAWINGS AND WITHIN THE SPECIFICATIONS ARE CONSIDERED AS "SPECIFIED STANDARDS" OF QUALITY AND WITH DIMENSIONS OF THE SPECIFIED MATERIALS FORM THE BASIS OF DESIGN- F, PRODUCTS: ALL MATERIALS SHALL BE NEW AND OF THE BEST QUALITY, FREE OF DEFECTS. WHERE APPLICABLE, ALL MATERIALS SHALL BE U.L. LISTED OR BE LISTED WITH AN APPROVED TESTING AGENCY. G. WORKMANSHIP: ALL MATERIALS SHALL BE FABRICATED AND INSTALLED IN A NEAT AND WORKMANLIKE MANNER WITH THE COORDINATION OF ALL TRADES TO AVOID INTERFERENCE AND DELAY DUE TO LACK OF COORDINATION. H. SHOP DRAWINGS: SUBMIT FOR ARCHITECTS.OWNER/ENGINEER REVIEW SHOP DRAWINGS FOR LIGHTING FIXTURES, PANELBOARDS, WIRING DEVICES AND OTHER MAJOR COMPONENTS AS INDICATED ON THE CONSTRUCTION DOCUMENTS. I. CLEANING, TESTING AND ADJUSTING: CLEAN, REPAIR, ADJUST, CHECK, BALANCE AND PLACE IN SERVICE THE VARIOUS SYSTEMS SHOWN ON THE CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL PROVIDE ALL TOOLS, EQUIPMENT AND MATERIALS REQUIRED TO PERFORM THE REQUIREMENTS OF THE SPECIFICATIONS AND THE REQUIREMENTS OF THE GOVERNING AUTHORITY. NO WORK SHALL BE COVERED OR CONCEALED UNTIL PROPERLY TESTED. J. GUARANTEE AND WARRANTY: PROVIDE WRITTEN GUARANTEE TO THE OWNER STATING THAT ALL WORK HAS BEEN PERFORMED IN ACCORDANCE WITH THE CONSTRUCTION DOCUMENTS AND WARRANTY ALL WORK AGAINST DEFECTS DUE TO FAULTY WORKMANSHIP OR MATERIALS FOR A PERIOD OF ONE YEAR FROM BENEFICIAL OCCUPANCY. K. AS -BUILT DRAWINGS: KEEP TWO SETS OF WHITE PRINTS ON THE JOB SITE, AND NEATLY MARK UP DESIGN DRAWINGS TO REFLECT MODIFICATIONS AND ALTERNATIONS MADE TO THE BASE DESIGN AS A RESULT OF OWNER DIRECTED REVISIONS OR COORDINATION WITH THE OTHER TRADES. L SERVICE INTERRUPTIONS AND UTILITY: COORDINATE WITH THE OWNER THE INTERRUPTION OF UTILITY SERVICES NECESSARY TO ACCOMPLISH THE WORK. M. IDENTIFICATION: PROPERLY LABEL ALL PANELBOARDS, DISTRIBUTION PANELBOARDS, SIGNAL DISTRIBUTION SYSTEMS INCLUDING FEEDER CIRCUITS. PROVIDE TWO COPIES OF TYPED PANELBOARD SCHEDULES. N. PERFORMANCE VERIFICATION: PRIOR TO THE FINAL INSPECTION TEST FEEDER AND BRANCH CIRCUIT CONDUCTORS 16 AWG AND LARGER FOR SHORTS, OPEN, INTENTIONAL AND UNINTENTIONAL GROUNDS BY MEANS OF AN APPROVED TYPE OF CONSTANT "MEGGER". PERFORM A TEST OF THE GROUND SYSTEM. THE RESISTANCE BETWEEN GROUND AND ABSOLUTE EARTH SHALL NOT EXCEED 25 OHMS. 0. LAYOUT OF WORK: CORRELATE FINAL EQUIPMENT LOCATIONS WITH GOVERNING ARCHITECTURAL DRAWINGS, PROVIDE COORDINATION OF ALL TRADES REQUIRED FOR INSTALLATION IN A NEAT AND WORKMANLIKE MANNER. P. SITE INVESTIGATION: CHECK SITE AND EXISTING CONDITIONS THOROUGHLY BEFORE BIDDING. ADVICE ARCHITECT OF DISCREPANCIES. R. SUPERVISION OF WORK: PROVIDE A FIELD SUPERINTENDENT WHO HAS A MINIMUM OF FOUR YEARS EXPERIENCE ON PROJECTS OF A SIMILAR NATURE AND SIZE. THE SUPERINTENDENT SHALL BE PRESENT AT ALL TIMES THAT WORK UNDER THIS DMSION IS BEING INSTALLED OR AFFECTED. S. COORDINATION: PROVIDE ALL COORDINATION AND SUPERVISION WHERE WORK CONNECTS TO OR IS AFFECTED BY OTHER TRADES. LOCATE ALL OPENINGS REQUIRED FOR WORK PERFORMED UNDER THIS SECTION. T. BASIS OF WIRING DESIGN: THE CONSTRUCTION DOCUMENTS DESCRIBE SPECIFIC SIZES OF EQUIPMENT. THESE SIZES ARE BASED UPON SPECIFIC ITEMS OF EQUIPMENT. WHEREVER THE CONTRACTOR PROVIDES EQUIPMENT WHICH DIFFERS FROM THE DOCUMENTS, THE ASSOCIATED WIRING AND CIRCUIT COMPONENTS SHALL BE CHANGED TO THE PROPER SIZE FOR THE EQUIPMENT BEING INSTALLED WITH NO ADDITIONAL COST TO THE OWNER. U. SURFACE MOUNTED EQUIPMENT AND RACEWAYS SHALL BE PAINTED UNDER DMSION 9. COLOR AS SELECTED BY THE ARCHITECT. V. PROTECTION AND CLEAN UP: SUITABLY PROTECT ALL EQUIPMENT AND FINISHES DURING CONSTRUCTION. RESTORE ALL DAMAGED SURFACES TO "LIKE NEW CONDITION". W. PROGRESS OF WORK: KEEP A DAILY JOB LOG OF WORK ACCOMPLISHED, FIELD DIRECTIONS AND EQUIPMENT RECEIVED ON THE JOB SITE. X. PROVIDE OPERATION AND MAINTENANCE MANUALS: FOR ELECTRICAL EQUIPMENT UTILIZED ON THE PROJECT. 1.2 MATERIALS AND WORKMANSHIP A. ASSUME FULL RESPONSIBILITY FOR THE TIMELY PLACEMENT OF ALL CONDUITS, OUTLET BOXES, CABINETS, AND OTHER WIRING DEVICES IN THE WALLS, CEILINGS, ETC., AS THE CONSTRUCTION PROGRESSES. B. RACEWAY AND CONDUIT SYSTEMS: 1. SIZE RACEWAY AS REQUIRED BY THE NATIONAL ELECTRICAL CODE WITH OVERSIZED CONDUITS AS INDICATED. PROVIDE COMPLETE RACEWAY SYSTEMS INCLUDING CONDUIT, SUPPORTS, BOXES AND ENCLOSURES AND ALL CONNECTIONS TO ELECTRICAL EQUIPMENT. CONCEAL RACEWAY IN FINISHED AREAS UNLESS INDICATED OTHERWISE. INSTALL EXPOSED RACEWAY PARALLEL OR PERPENDICULAR TO WALLS, CEILING OR STRUCTURAL MEMBERS. 2, CONDUIT SYSTEMS SHALL BE SUSPENDED FROM OR AFFIXED TO THE BUILDING SUPERSTRUCTURE ONLY. 3. ALL RACEWAYS SHALL BE RUN IN A NEAT AND WORKMANLIKE MANNER AND SHALL BE PROPERLY SUPPORTED IN ACCORDANCE WITH THE NEC WITH APPROVED CONDUIT STRAPS, CLAMPS, HANGER RODS AND STRUCTURAL FASTENERS. NON -BOLTED CONDUIT CLAMPS SUPPORTING OF THE CONDUIT SYSTEM FROM SUSPENDED CEILINGS IS NOT BE PERMITTED. 4. ALL RACEWAYS SHALL BE CAPPED DURING THE COURSE OF CONSTRUCTION. NO CONDUCTORS SHALL BE PULLED UNTIL THE RACEWAY SYSTEM IS COMPLETE. 5. RACEWAYS FOR BRANCH CIRCUITS AND FEEDERS SHALL HAVE AN INSULATED COPPER SYSTEM GROUND CONDUCTOR THROUGHOUT THE ENTIRE LENGTH OF THE CIRCUIT IN ACCORDANCE WITH THE NEC. GROUNDING CONDUCTORS SHALL BE INCLUDED IN THE TOTAL CONDUIT FILL WHEN DETERMINING CONDUIT SIZE. 6. AN APPROVED NYLON PULL -CORD SHALL BE INSTALLED IN ALL EMPTY CONDUITS. PULLCORDS SHALL BE FASTENED TO PREVENT ACCIDENTAL REMOVAL- 7. CIRCUIT NUMBERS AND SYSTEM IDENTIFICATION SHALL BE PRINTED ON JUNCTION BOX COVERS USING INK MARKERS AND BE PLAINLY VISIBLE. 8. CONDUIT SHALL BE EMT FOR BRANCH CIRCUIT WIRING WITH CAST FERROUS COMPRESSION. SET SCREW FITTINGS. METAL CLAD CABLE (MC) MAY BE USED WHERE ALLOWED BY CODE. MC CABLE SHALL NOT BE USED WHERE EXPOSED. MC CABLE SHALL BE USED IN WIRING CHANNELS IN BOTTOM OF WOOD MEMBERS. PVC (SCH 40) SHALL BE USED BELOW GRADE ONLY. PVC CONDUIT SHALL TRANSITION TO RIGID GALVANIZED STEEL BELOW GRADE, PRIOR TO STUB -UP. FLEXIBLE CONDUIT SHALL BE USED TO MAKE FINAL CONNECTION TO ELECTRICAL EQUIPMENT WHERE REQUIRED, 36" MAX. LIQUID TIGHT SHALL BE USED FOR EXTERIOR APPLICATIONS, 36" MAX. C. WIRE AND CABLE: 1. BRANCH CIRCUIT AND FEEDER CONDUCTORS SHALL BE COPPER 600 VOLT TYPE THHN, THWN OR THW. CONDUCTORS # 10 AWG AND SMALLER SHALL BE SOLID, THE MINIMUM WIRE SIZE SHALL BE #12 AWG UNLESS NOTED OTHERWISE. NO ALUMINUM WIRE SHALL BE PERMITTED. 2. ALL COPPER TAPS AND SPLICES NO. 8 AWG OR SMALLER SHALL BE FASTENED WITH WIRENUT CONNECTORS. ALL TAPS AND SPLICES LARGER THAN NO. 8 AWG SHALL BE MADE WITH COLOR KEYED HIGH COMPRESSION TYPE CONNECTORS, AN APPROVED SHRINK SLEEVE TO EQUAL INSULATION RATING OF THE WIRE SHALL BE USED TO INSULATE SPLICES. 3. ALL POWER FEEDERS AND BRANCH CIRCUITS #8 AWC AND SMALLER SHALL BE WIRED WITH COLOR -CODED WIRE AS HEREIN SPECIFIED. POWER FEEDERS #8 AWG AND LARGER SHALL EITHER BE COLOR -CODED WITH TAPE OR PAINT IN ALL JUNCTION BOXES AND PANELS. 120/208 VOLT: BLACK -RED. -BLUE (PHASES A-B-C) NEUTRALS - WHITE GROUND - GREEN, BARE OR GREEN WITH YELLOW STRIPES SWITCH LEGS - OTHER THAN THOSE UTILIZED ABOVE. 277/480 VOLT - ORANGE, BROWN, YELLOW. PHASES A, B & C. D. OUTLET BOXES: 1. OUTLET BOXES SHALL BE AS REQUIRED FOR THE SPECIFIC USE AND LOCATION, TYPE OF DEVICE OR FIXTURES TO BE USED, AND NUMBER AND SIZE OF CONDUCTORS. MINIMUM SINGLE GANG. BOXES SHALL BE OF ONE PIECE CONSTRUCTION. WELDED BOXES WILL NOT BE APPROVED. 2_ SURFACE BOXES CAST FERROUS WITH INTEGRAL HUBS 3, CEILING BOXES 4" SQUARE BY 1-1/2" DEEP OR LARGER AS REQUIRED FOR NUMBER AND SIZE OF CONDUCTORS. 4. FLUSH OUTLET BOXES, ONE PIECE STEEL OUTLET BOXES BY STEEL CITY OR RACO. BOXES SHALL BE MOUNTED SO THAT COVERS AND PLATES WILL FINISH FLUSH WITH FINISHED SURFACES WITHOUT THE USE OF SHIMS, MATS, OR OTHER DEVICES- PLATES SHALL NOT SUPPORT WIRING DEVICES, GANG SWITCHES WITH COMMON COVERPLATES WHERE TWO OR MORE ARE INDICATED IN THE SAME LOCATION. OUTLETS ON EACH SIDE OF THE WALL SHALL HAVE SEPARATE BOXES, THROUGH -WALL TYPE BOXES OR BACK-TO-BACK MOUNTING SHALL NOT BE PERMITTED. TRIM RINGS SHALL BE EXTENDED TO WITHIN 1/4" OF FINISH WALL SURFACE. 5. OUTLET BOXES MOUNTED IN STUD WALLS ARE TO BE SUPPORTED TO STUDS WITH TWO SCREWS INSIDE OF OUTLET BOX TO A HORIZONTAL STUD BRACE BETWEEN VERTICAL STUDS. 6. OUTLET BOXES THAT DO NOT RECEIVE WIRING DEVICES SHALL BE PROVIDED WITH BLANK PLATES TO MATCH INSTALLED WIRING DEVICE PLATES. 7. OUTLET BOXES/CONDUIT BODIES EXPOSED TO THE WEATHER, NOT CONTAINED INSIDE BUILDING WALLS, SHALL BE TYPE FS, FD, LB OR LL MALLEABLE IRON. COVERS SHALL BE OF THE TYPE AND OF THE SAME MANUFACTURER AS THE CONDUIT BODIES AND SHALL BE SUITABLE FOR THE USE IN THE AREA SERVED- CAST ALUMINUM BOXES WILL NOT BE APPROVED. 8. MOUNTING HEIGHTS OF DEVICES (UNLESS OTHERWISE NOTED) SWITCHES 48" TO CENTER RECEPTACLES 18' TO CENTER TELEPHONE/DATA OUTLET 18" TO CENTER LIGHTING PANELS 6'-6" TO TOP OF PANEL TRIM. ALL WIRING DEVICES SHALL BE SPECIFICATION GRADE, ARROW HART OR EQUAL. 9. LOCATE SPECIAL PURPOSE OUTLETS AS INDICATED ON THE DRAWINGS FOR THE EQUIPMENT SERVED. LOCATION AND TYPE OF OUTLETS SHALL BE COORDINATED WITH THE APPROPRIATE TRADES INVOLVED. THE SECURING OF COMPLETE INFORMATION FOR PROPER ELECTRICAL ROUGH -IN SHALL BE INCLUDED AS WORK REQUIRED UNDER THIS DMSION OF THE CONTRACT. F. CONVENIENCE RECEPTACLES SHALL BE 20 AMP, 125 VOLT NEMA 5-20R, UNLESS NOTED OTHERWISE. COVER PLATES SHALL MATCH ADJACENT SURFACE. COVER PLATES IN KITCHEN SHALL BE STAINLESS STEEL G. WALL SWITCHES SHALL BE 20 AMP, 120/277 V AC, SINGLE POLE, UNLESS NOTED OTHERWISE. COVER PLATES SHALL MATCH ADJACENT SURFACE. COVER PLATES IN KITCHEN SHALL BE STAINLESS STEEL H. WIRING DEVICE PLATES SHALL BE PLASTIC, PAINTED TO MATCH WALL, IN DINING ROOMS, STAINLESS STEEL IN KITCHEN ANC BAR AREAS AND IVORY PLASTIC IN OFFICE, LIQUOR STORAGE ROOM AND TOILETS. PROVIDE BLANK COVER PLATES FOR ALL UNUSED OUTLETS (DATA TELEPHONE, ETC.). I. PROVIDE PANELBOARDS AS SCHEDULED ON THE DRAWINGS. CUTLER HAMMER, SQUARE D, OR SIEMENS ALL TERMINALS SHALL BE RATED FOR 75 DEGREES C MINIMUM. ALL PANELBOXRDS SHALL HAVE SOLID COPPER BUSSES. SHORT CIRCUIT RATING SFAL.L BE AS LISTED ON PANEL SCHEDULES. J. GROUND THE ELECTRICAL SYSTEM IN ACCORDANCE WITH ARTICLE 250 OF THE NATIONAL ELECTRICAL CODE AND WITH LOCAL REQUIREMENTS. GROUND SERVICE TO BUILDING STEEL, DRIVEN GROUND ROD, AND COLD WATER PIPE. K. MAKE FINAL CONNECTIONS TO ALI. ELECTRICAL EQUIPMENT SET IN PLACE BY OTHERS. MAKE ELECTRICAL CONNECTIONS O ALL ITEMS SHOWN AS PART OF THE GENERAL CONTRACT WHICH REQUIRE ELECTRICITY. L FURNISH AND INSTALL EQUIPMENT DISCONNECTS AS INDICATED OR REQUIRED. FUSES IN ALL DISCONNECT SWITCHES AND OTHER FUSIBLE DEVICE SHALL BE DUAL ELEMENT CURRENT LIMITING TYPE. FURNISH WITH 3 SPARE FUSES OF EACH TYPE AND SIZE USED ON THE JOB. SWITCHES AND FUSES SM.-L BE SIZE TO SUIT THE ACTUAL EQUIPMENT BEING SERVED- M. CONNECT MOTOR STARTERS, RELN(S, SWITCHES, AND RELATED ITEMS WHICH ARE PROVIDED UNDER THE MECHANICAL WORK. N. DUCTWORK TAKES PRECEDENCE OVER ELECTRICAL CONDUIT. COORDINATE CONDUIT RUNS TO ALLOW DUCTWORK TO BE INSTALLED AS DRAWN. LIGHT FIXTURES TAKE PRECEDENCE OVER DUCTWORK. 0. ALL INTERIOR LIGHTS SHALL BE CONTROLLED FROM WALL SWITCHES. UGHTS SHALL NOT BE SWITCHED FROM PANELS P. ALL ENCLOSURES SHALL BE OF THE NEMA TYPE WHICH IS SUITABLE FOR THE APPLICATION. R, ALL WORK SHALL HAVE PROPER LABEUNG. ALL CIRCUITS SHALL BE LABELED AT PANELS AND BOXES AS INDICATED. ALL PANELS AND DISCONNECTS ARE TO BE PERMANENTLY MARKED WITH NAME OR EQUIPMENT SERVED UTILIZING ENGRAVED NAMEPLATES, LAMINATED PHENOLIC BLACK WITH WHITE LETTERS, 3/8" MIN. ALL PANELS ARE TO BE APPROVED WITH TYPE WRITTEN PANEL SCHEDULES. S. ALL CIRCUIT BREAKERS SERVING AIR CONDITIONING AND REFRIGERATION EQUIPMENT SHALL BE HACR RATED. T. PROVIDE AND INSTALL CONDUIT AND JUNCTION BOXES FOR INTERIOR LIGHTING AS INDICATED AND/OR REQUIRED. U. DISCONNECT SWITCHES SHALL BE RATED HEAVY DUTY, FULLY ENCLOSED WITH DUAL COVER LOCKS, QUICK-MAKE/QUICK-BREAK MECHANISMS AND DUAL HORSEPOWER RATED. PROVIDE NEMA-3R ENCLOSURES IN EXTERIOR OR DAMP LOCATIONS AND NEMA-4 ENCLOSURES IN WET LOCATIONS. PROVIDE FUSED AND NON -FUSED AS INDICATED ON THE DRAWINGS. PROVIDE FUSE CLIPS ON FUSIBLE SWITCHES OF 30A TO 600 AMPS TO PREVENT INSTALLATION OF NON -CURRENT LIMITING FUSES. V_ UGHTING FIXTURES SHALL BE FURNISHED COMPLETE WITH LAMPS AND ALL NECESSARY TRIM AND MOUNTING HARDWARE AND INSTALLED AS SHOWN ON THE DRAWINGS AND PER THE MANUFACTURER'S RECOMMENDED INSTALLATION GUIDES. FIXTURES SHALL BE FIRMLY MOUNTED USING STANDARD SUPPORTS FOR OUTLET AND FIXTURES. LAMPS SHALL HAVE A 30 DAY GUARANTEE AFTER FINAL ACCEPTANCE OF THE SPACE. W. EXTEND EXISTING BUILDING FIRE ALARM SYSTEM AS REQUIRED TO ACCOMODATE NEW RECREATIONAL WAREHOUSE FACILITY. PROVIDE EQUIPMENT TO MATCH EXISTING MALL INSTALLATION. END OF DIVISION 16000 ELECTRICAL SYMBOL LIST FLOURESCENT FIXTURE, RECESSED TROFFER, 2'x4' & 2'x2' RECESSED FLUORESCENT FIXTURE WITH BATTERY PACK. 0-i WALL MOUNTED EXIT LIGHT Y3 WALL MOUNTED EMERGENCY LIGHT, BATTERY UNIT DUPLEX RECEPTACLE, NEMA 5-20R, 15"AFF- DUPLEX RECEPTACLE, NEMA 5-20R, 45"AFF OR AS NOTED IE� DUPLEX RECEPTACLE, NEMA 5-20R, GFI, 15"AFF. ii4 DUPLEX RECEPTACLE, NEMA 5-20R, GFI, 45"AFF OR AS NOTED a SWITCH, SINGLE POLE, 20A 120/277 VOLT. 45" AFF - SUB LETTER DENOTES SWITCHING CIRCUIT 3 SWITCH, 3 WAY, 20A 120/277 VOLT. 45" AFF - SUB a LETTER DENOTES SWITCHING CIRCUIT O JUNCTION BOX OR EQUIPMENT CONNECTION ® EXHAUST FAN OH COMBINATION HEAT DETECTOR 04 FIRE ALARM HORN AND STROBE UNIT, 8'-0" AFF (D CEILING MOUNTED SMOKE DETECTOR WIRING, CONCEAAED ABOVE CEILING OR IN WALL, OR EXPOSED / ARROWHEADS INDICATE HOMERUN CIRCUITS. WIRING, IN SLAB OR BELOW GRADE, ARROWHEADS AS ABOVE. AFF ABOVE FINISH FLOOR NFSS NON FUSIBLE SAFETY SWITCH FLOOR LINE TO REMAIN AS IS 1, TO REMAIN AS IS C1 C2 1 C3 C4 C5 C6 C7 C8 C9 EXISTING 3' CONDUIT TO I RECREATIONAL WAREHOUSE SPACE--_iLj O PROVIDE NEW 200A SWITCH IN EXISTING SPACE C3. FUSE AT 125A. DETAIL - MAIN SWITCHBOARD - ELECTRIC ROOM 2A NOT TO SCALE N OA 4B 0C GND PRIMARY FEEDER MER PAD )V FEEDER TO PANEL 'A' OA N OB 0C 75 KVA TRANSFORMER WIRING DIAGRAM NOT TO SCALE - - - - - - - - - - - - - - a I 3 I I I I I 5 I I I I 0 I I ) 8 I I I I I I I I I RECREATION WAREHOUSE AREA ----------------t n FrTRir Rnnu 9A nm r---------- --- t I I I EXISTING SWITCHBOARD I t---------- ---I EXISTII G ELECTRIC ROOM 26 SINGLE LINE DIAGRAM REFERENCED NOTES: 1. NEW 200A SWITCH IN EXISTING SWITCHBOARD. 2. NEW 4#2 & 1 #4 GND IN EXISTING 2"C. 3. NEW 4#2 & 1#6 GND IN NEW 2"C. 4. NEW 75 KVA - 480A/208Y-120V DRY TYPE TRANSFORMER. 5. NEW 4#4/0 & 1#4 GND IN 2-1/2"C. 6. NEW PANEL W. SEE SCHEDULE. 7. TVSS - 80 KAIC - CUTLER HAMMER OR EQUAL 8. 4#10 & 1#6 GND IN 1"C. PARTIAL SINGLE LINE DIAGRAM NOT TO SCALE NATIONAL ENGINEERING CORP, Consulting Engineers FL Cert. of Autd. j WJ 220 Live Oaks Boulevard, Casselberry, FL 32707 407 539-3400 James M. Fowler, Jr., FS / 4M71 03032 ©2003 national Engineering Cap, All Rights Reserved 9-5-03 0 c G c Q V 0 W E-+ CL U � � O a a {� a Q w n 00 Cp r�r�� U '�o cf) o I s V1 �`n0 of c) W co � 00 O z 0 W N Q U) 0. Z 0 N 0 _ 0 NJ V E �I_ 0 W 1 _ r CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECT OF ANY DIMENSIONAL. ERRORS, OMISSIONS OR DISCREPANCIES BEFORE BEGINING OR FABRICATING ANY WORK. DO NOT SCALE DRAWINGS. N v 0 a K 0 U L 0 O L L_ to O Z � � W a __j U O _ U = V) ® O Q W Z J Li .2 0 FF L.L�J O < ® O O Z o W z a (n Qw o 4 W V) O3. 0 3 W Z 0 a N z 2 U a O U DRAWN BAV CHECKED JDW DATE 09/02/03 SCALE AS NOTED PROJECT NO. H32503 FILE NAME 3032-El SHEET E-1 4 VOLTAGE: 208YI 120 3 PHASE 4 WIRE Y PANEL A PANEL TYPE: NQOD MAINS: 225A. MAIN CIRCUIT BREAKER NEUTRAL BUS AMPACITY 100% SQUARE D OR EQUAL MOUNTING: FLUSH AIC RATING 10K GROUND BUS AMPACITY 50% CIRCUIT IDENTIFICATION PHASE A KVA PHASE B KVA PHASE C KVA DEMAND FACTOR DEMAND KVA TRIP AMPS POLES CIRCUIT # CIRCUIT # POLES TRIP AMPS PHASE A KVA PHASE B KVA PHASE C KVA DEMAND FACTOR KVA DEMAND CIRCUIT IDENTIFICATION SALES AREAS LIGHTING 0.90 0.00 0.00 1.25 1.13 20 1 1 2 1 20 1.50 0.00 0.00 1.00 1.50 SALES ROOM RECEPTS. SALES AREAS LIGHTING 0.00 0.90 0.00 1.25 1.13 20 1 3 4 1 20 0.00 1.50 0.00 1.00 1.50 SALES ROOM RECEPTS. SALES AREAS LIGHTING 0.00 0.00 0.90 1.25 1.13 20 1 5 6 1 20 0.00 0.00 1.50 1.00 1.50 SALES ROOM RECEPTS. SALES AREAS LIGHTING 0.90 0.00 0.00 1.25 1.13 20 1 7 8 1 20 1.50 0.00 0.00 1.00 1.50 SALES ROOM RECEPTS. SALES AREAS LIGHTING 0.00 0.90 0.00 1.25 1.13 20 1 9 10 1 20 0.00 1.50 0.00 1.00 1.50 SALES ROOM RECEPTS. SALES AREAS LIGHTING 0.00 0.00 0.90 1.25 1.13 20 1 11 12 1 20 0.00 0.00 1,50 1.00 1.50 STOCK RM RECEPTS. STOCK ROOM LIGHTING 0.72 0.00 0.00 1.25 0.90 20 1 13 14 1 20 1.50 0.00 0.00 1.00 1.50 TOILET GFI RECEPTT. SIGN OUTLET 0.00 1.00 0.00 1.00 1.00 20 1 15 16 1 20 0.00 0.50 0.00 1.00 0.50 TELEPHONJE RECEPT. SPACE ONLY 0.00 0.00 0.00 0.00 0.00 1 17 18 1 1 20 0.00 0.00 0.00 1.00 0.00 VAV UNITS SPACE ONLY 0.00 0.00 0.00 0.00 0.00 1 19 20 1 0.00 0.00 0,00 0.00 0.00 SPACE ONLY SPACE ONLY 0.00 0.00 0.00 0.00 0.00 1 21 22 1 0.00 0.00 0.00 0.00 0.00 SPACE ONLY SPACE ONLY 0.00 0.00 0.00 0.00 0.00 1 23 24 1 0.00 0.00 0.00 0.00 0.00 SPACE CIINLY SPACE ONLY 0.00 0.00 0.00 0.00 0.00 1 25 26 1 0.00 0.00 0.00 0.00 0.00 SPACE ONLY SPACE ONLY 0.00 0.00 0.00 0.00 0.00 1 27 28 1 0.00 0.00 0.00 0.00 0.00 SPACE ONLY SPACE ONLY 0.00 0.00 0.00 0.00 0.00 1 29 30 1 0.00 0.00 0.00 0.00 0.00 SPACE 0,',11Y SPACE ONLY 0.00 0.00 0,00 0.00 0.00 1 31 32 1 0.00 0.00 0.00 0.00 0.00 SPACE <, N Y SPACE ONLY 0.00 0.00 0.00 0.00 0.00 1 33 34 1 0.00 0.00 0.00 0.00 0.00 SPACE ONLY SPACE ONLY 0.00 0.00 0.00 0.00 0.00 1 35 36 1 0.00 0.00 0.00 0.00 0.00 SPACE ONLY SPACE ONLY 0.00 0.00 0.00 0.00 0.00 1 37 38 1 0.00 0.00 0.00 0.00 0.00 SPACE ONLY SPACE ONLY 0.00 0.00 0.00 0.00 0.00 1 39 40 1 0.00 0.00 0.00 0.00 0.00 SPACE ONLY SPACE ONLY 0.00 0.00 0.00 0.00 0.00 1 41 42 1 0.00 0.00 0.00 0.00 0.00 SPACE ONLY TOTAL PHASE KVA 2.52 2.80 1.80 4.50 1 3.50 1 3.00 TOTAL CONN. AMPERES 58.E DEMAND AMPS. 54.58 MAX. PHASE AMPERES 58.50 TOTAL CONN. AMPERES 52.60 TOTAL CONNECTED KVA 18.12 TOTAL CONN. AMPERES 40.00 DEMAND KVA 19.65 SHORT CIRCUIT ANALYSIS SUMMARY PROJECT:RECREATIONAL WHS. SEMINOLE TOWN CTR. DATE: 08/29/03 SYSTEM MVA. 500.00 BASE ( TRANSFORMER) KVA: 1000 TRANS. P.UZ 5.75 CALCULATED Isc AT TRANSFORMER TERMINALS 4045.63 FAULT FAULT LOCATION P.0 Z TO FAULT NOTES Isc AT FAULT 1 UTILIZATION TRANS. PRIMARY 0.5071412 2371.75 2 PANEL A BUS 0.0614577 4045.63 3 0.00 0.0000000 0.00 4 0.00 0.0000000 0.00 5 0.00 0.0000000 0.00 6 0.00 0.0000000 0.00 7 0.00 0.0000000 0.00 8 0.00 0.0000000 0.00 9 0.00 0.0000000 0.00 10 1 0.00 0.0000000 0.00 LIGHTING FIXTURE SCHEDULE SYM, TYPE MTG. MANUFACTURER & CATALOG NUMBER FIXTURE LAMPS VOLTS QUANTITY WATTS A FLUOR RECESS LITHONIA #2FM3N-G-B-2-U31-9-W 120 OR EQUAL 120 2 31 Al FLUOR RECESS SAME AS A VVITH EMERGENCY BATTERY PACK 120 2 31 B FLUOR RECESS LITHONIA # 2GT-232-Al2-120 120 2 32 E INC. WALL EMERGENCY WALL MOUNTED UNIT. LITHONIA ELM-120-ELN ORE U L 120 X EXIT WALL LITHONIA # LQM SB 1 R 120/277 EL N OR EQUAL - r SEMINOLE TOWN CENTSR, RECREATIONAL WAREHOUSE MO.:iIMUM DIV. DER DEMAND FAC. KVA LOAD ITEM AREA K/SF WATTS 15F POWER FACT. CONN. KVA DEM. FAC. INTERIOR LTG, RETAIL AREA 4A 3 0.9 14.67 1.25 18.33 1 18.3 MISC AREAS 0.591 2 0.95 1.24 1.25 1.56 1 1.501 SHOW WINDOW 95 LF 200WILF 19. 1.261 23.75 1 23.7 HVAC MAX. AV BOXES ONLY) 0.50 1.28 0.63 1 0.63 MISC LOADS 4.951 1 0.85 5.02 1 5.82 1 5.8 TOTALS 50.0 SYSTEM KV. 0.208 PHASE$ 3 MAXIMUM DEMAND AMPERES 139.05 SERVICE AMPACITY _ 200A. K.3 - J.8 - R ELECTICAL PLAN SCALE: 3/16" = 1'-0" 0 4 8 10 (FEET) 20 GRAPHIC SCALE REFERENCED NO TES: in 1. APPROXIMATE LOCATION - 2" EMPTY CONDUIT FROM EXISTING SWITCHBOARD IN ELECTRIC ROOM 2A. SEE SINGLE LINE POWER DIAGRAM FOR DETAILS. 2. APPROXIMATE LOCATION OF EXISTING TELEPHONE CABLE. EXTEND TO NEW TERMINAL BOARD ABOVE DROPPED CEILING. 3. NEW 48OA-208Y/120 VOLT, 75 KVA DRY TYPE TRANSFORMER. PROVIDE TRAPEZE HANGER AND SUSPEND FROM STRUCTURE ABOVE. LOCATE TRANSFORMER WITH 1' CLEARANCE FROM TOP OF TRANSFORMER TO DROPPED CEILING ABOVE. 4. NEW PANEL 'A'_ MOUNT SO TOP OF PANEL IS 6'-6" AFF. 5_ NEW TELEPHONE TERMINAL BOARD., 3/44 4'x4' PLYWOOD, PAINT WITH 2 COATS OF BLACK ENAMEL LOCATE TOP OF BOARD 6'-6' AFF. 6. EXACT SIGN OUTLET LOCATION AS DIRECTED BY OWNER. ALL NEUTRAL -R NATIONAL ENGINEERING C ORR Consulting Engineers FL cerL or dat6. { d= 220 Live Oaks Boulevard, Casselberry, FL 32707 407/539-3400 James X. Fowler Jr., Ps / 4W71 03032 ©2003 Na6ml Engineering Corp., AN Rights Rmf'vd9-5-03 0 iE 0 a. V) v� �3 0 -o 0 c a> V) 0 0 c �® 0 C) �4 0 0 U a r. o. �] w � 00 O V1 Q _ �--► Q o t a o CID ft: ► r- w of u� co � C11ZLJc=Q o oLL V) ;4 Q a � a o� C-)W is N I�-1 ►-a 0 v s N E lu 0 0 N /t v V � V � V) N L O� L N t CONTRACTOR SHALL VERIFY ALL; CONDITIONS AND ° DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECT a OF ANY DIMENSIONAL ERRORS, S OMISSIONS OR DISCREPANCIES BEFORE BEGINING OR z FABRICATING ANY WORK. DO NOT SCALE DRAWINGS. 0 0 a. 0 V C N r 0 Q o a Z -o J w 0 a o LZL I (� r� c L! 1 -' w Uo v? < LEI o U l O Cr Q Q a_ 0 V)J Li �, 0 z �_ w a ° _j Z V� Q FTC vCL W 2 a V) v ry s O v o rn LLd�� 31;1� v z v_ v N N t F- �O n: m V) z 0 V) W 0 O Z N I i -J-j DRAWN BAV CHECKED JDW DATE 09/02/03 SCALE AS NOTED PROJECT NO. H32503 FILE NAME 3032-E2 SHEET E-2 TOWEL DISPENSER NEW GRAB BARS PROVIDE BLOCKING AS REQUIRED FOR SUPPORT NEW SURFACE MOUNTED TOILET TISSUE HOLDER ROOM FINISH SCHEDULE ROOM FLOOR BASE WALLS CEILING HEIGHT SALES AREA BY TENANT WOOD PAINT ALL WALLS NEW ACOUST. 14'-0" RESTROOM VINYL VINYL PAINT ALL WALLS NEW ACOUST, 8'-0" STOCK ROOM CONC. VINYL PAINT ALL WALLS NEW ACOUST, 14'-0" FINISH NOTES VINYL FLOORING SHEET VINYL FLOORING IS TO BE SELECTED AND PROVIDED BY TENANT. GENERAL CONTRACTOR TO INSTALL ALL VINYL FLOORING. NOTE: PROVIDE VINYL TRANSITION STRIP BETWEEN AREAS WITH CARPET AND AREA WITH VINYL. VINYL BASE 4" VINYL BASE SELECTED AND PROVIDED BY TENANT. INSTALLED BY GENERAL CONTRACTOR. WALL PAINT ONE (1) COAT VINYL PRIMER PLUS TWO (2) COATS VINYL PLASTIC PAINT (EGGSHELL FINISH). NEW 1x4 WOOD BASE (FIR) ONE (1) COAT ENAMEL UNDERCOAT PLUS TWO (2) COATS SEMI -GLOSS. NEW WOOD DOORS/FRAMES ONE (1) COAT ENAMEL UNDERCOAT PLUS TWO (2) COATS SEMI -GLOSS. NEW METAL DOOR FRAMES ONE (1) COAT ENAMEL UNDERCOAT PLUS TWO (2) COATS SEMI -GLOSS. DOOR SCHEDULE # SIZE THK. MATERIAL FRAME TYPE REMARKS HARDWAR E1. 3'-0"x6'-8" 1-3/4" METAL EXIST. FLUSH REPLACE EXIST_ EXIT DOOR 2 1. 16'-0"x13'-0" - ALUM. ALUM. - OVERHEAD ROLLING GRILLE 2 3'-0"x6'-8" 1-3/4" WOOD METAL FLUSH NEW INTERIOR DOOR 1 DOOR NOTES: (PROVIDE HARDWARE AS SPECIFIED OR EQUAL TO) 1. ALL NEW WOOD DOORS ARE TO BE PAINT GRADE BIRCH. 2. LOCKING DEVICES ON REQUIRED EXIT DOORS SHALL NOT REQUIRE THE USE OF A KEY FOR OPERATION FROM INSIDE THE BUILDING. 3. DOOR LOCKSETS/PASSAGE SETS ARE TO BE SCHLAGE LOCKS WITH LEVER ACTION HANDLES. 4. CONTRACTOR IS TO ADJUST ALL DOORS TO NORMAL WORKING OPERATION WHICH INCLUDES THE REPAIR OR REPLACEMENT OF HARDWARE AND WEATHER STRIPPING AS REQUIRED. 5. UNDER CUT INTERIOR DOORS 1/2." 6. REUSE ALL UNDAMAGED EXISTING DOORS, FRAMES AND DOOR HARDWARE. EXCEPTION: REPLACE ALL DOOR KNOBS WITH NEW SCHLAGE DOOR LEVER HANDLES. GROUP #1 1-1/2 PR, BUTTS SELF CLOSING SPRING HINGES 4-1/2 X 4-1/2 1 LOCKSET SCHLAGE 2-3/4" BSXASA 1 WALL MOUNTED DOOR STOP IVEY GROUP # REUSE AND REMOUNT EXISTING HARDWARE. EXISTING METAL DOOR FRAME TO REMAIN AS IS. WALL TYPES LEGEND: FULL HEIGHT PARTITION TO CEILING GRID. SEE WALL SECTIONS ON SHEEP A-2_ INTERIOR FINISH REQUIREMENTS: MINIMUM FLAME SPREAD CLASSIFICATIONS: EXITS - CLASS C. - FLAME SPREAD 76-200, SMOKE DEVELOPED 0-450. EXITS ACCESS - CLASS C.- FLAME SPREAD 76-200, SMOKE DEVELOPED 0-450. OTHER SPACES - CLASS C.- FLAME SPREAD 76-200, SMOKE DEVELOPED 0-450. ELECTRICAL LEGEND 6 NEW 110 V. 3 POLE DUPLEX OUTLET. CIRCUIT AS REQUIRED. NEW JUNCTION BOX FOR TELEPHONE. -4 1" CONDUIT TO ABOVE CEILING W/ PULL STRINGS © NEW JUNCTION BOX FOR COMPUTER CABLING. 1 CONDUIT W/ PULL STRINGS NEW 110V 3 POLE FOURPLEX OUTLET CIRCUIT AS REQUIRED NEW 11OV 3 POLE DUPLEX OUTLET MOUNTED ®C ABOVE THE CEILING ON THE WALL NEW FLOOR MOUNTED TELEPHONE JUNCTION BOX WITH 1' F CONDUIT OVER WALL AND UP WALL TO ABOVE CEILING W/ PULL STRINGS ® NEW FLOOR MOUNTED DEDICATED DUPLEX COMPUTER OUTLET F NEW SPECIAL PURPOSE OUTLET FOR STACK WASHER AND DRYER N = NEW DEVICE R = RELOCATED DEVICE DEVICES WITHOUT DESIGNATION ARE EXISTING © NEW JUNCTION BOX AND SWITCH FOR WATER HEATER 220 V, 3 PH. ® 41" A.F.F. NEW SURFACE PAINTED MOUNTED PAPER GYP. BD 4" 3'-0" IL NEW N SINK � � I ^I I cv NEW WRAP DRAIN WATER CLOSET- 1'-6" 3'-2" PIPE WITH CLEAR INSULATION R�El ROO�- LEVATION A SCAL/2" = 10 h LOOK FLAN KtT NV I t� u 1. NEW CONCRETE FLOOR SLAB (2500 PSI WITH FIBER MESH) WITH GEOTEXTILE WATERPROOFING LINER. PROVIDE CRACK CONTROL JOINTS @ 15 FT. O.C. EACH WAY. 2. NEW SUITE SERVICE ELECTRICAL PANEL. 3. NEW STEP DOWN TRANSFORMER. 4. NEW DUPLEX RECEPTACLE OUTLET. 5. NEW PART+TION WALL W/ 3-5/8" 250A_ METAL STUDS @ 16" O.C. AND 5/8" GYP. BD. BOTH SIDES. 6. FURR OUT EXISTING WALL WITH 3-5/8" 25GA. METAL STUDS @ 16" O.C. AND 5/8" GYP. BD. ONE SIDE. 7. INSTALL NEW 5/8" TYPE 'X' GYP. BD. OVER ONE SIDE OF EXISTING mTL. STUDS. 8. BOX OUT EXISTING COLUMN WITH 3 5/8" 25 GA_ MTL. STUDS AND 5/8" TYPE 'X' GYP. BD. ONE SIDE. 9. BOX OUT EXISTING RAIN LEADER WITH 3 5/8" 25 GA. MTL. STUDS AND 5/8" TYPE 'X' GYP. BD. ONE SIDE. 10. PROVIDE BLOCKING AND ADDITIONAL METAL STUD SUPPORTS AS REQUIRED FOR WATER HEATER SUPPORT SHELF. 11. INSTALL NLFW 2 LAYERS 5/8" TYPE 'X' GYP. BD. ONE SIDE OVER EXISTING METAL STUDS. 12. CONTRACTOR TO SUPPLY AND INSTALL t 120 L.F. 8'-0"H. SLAT WALL. ATTACH TO WALL WITH SCREWS THROUGH THE GYP. BD. FINISH INTO THE METAL WALL STUDS PER MANUFACTURER'S RECOMMENDATIONS. 13. CONTRACTOR TO SUPPLY AND INSTALL 60 L.F. OF PLUG MOLD TO BE MOUNTED ON THE WALL ABOVE THE SLAT WALL. SEE SHEET E-2. N EW GRAB BARS PROVIDE BLOCKING AS REQUIRED FOR SUPPORT - .3'-6" J NEW SURFACE - MTD. TOILET TISSUE HOLDER I I CIA NEW WATER CLOSET RESTROOM ELEVATION B scALE 1 /2' = 1'-0" m 1114, MMA. EQUIPMENT PERMITTED IN SHADED AREA HANDICAP WATER BUBBLER DETAIL SCALE: 1 " = 1'-0" CONTRACTOR IS TO INSTALL NEW PLUMBING PIPING INTO NEW STUD WALL AND NOT INTO EXISTING FIRE -RATED WALL. r4-t-I r DFTNDO1 D.DWG O i WC-1 o Y, j --,c X" L-1 Ll MS-1 3'-611 " -6•" 3 -3 2 -8 `-NEW WATER HEATER _~ MOUNTED ABOVE_ I I B A II I II 'T" SHAPED HANDICAP ACCESSIBLE TURNAROUND iRESTROOM 71_11Z�LZZZ4��IIZ77 -411 T44 7 -5"5„ ENLARGED RESTROOM PLAN SCALE: 1/2" = V-0" SUITE GENERALNOTES GENERAL CONTRACTOR SHALL REFER TO THE TECHNICAL GUIDELINES FOR THE SEMINOLE TOWNE CENTER BY THE SIMON PROPERTY GROUP, CK3 c� e� ELECTRICAL GENERAL NOTES 1. SEE ELECTRICAL DRAWINGS ('E' SHEETS) IN THIS SET OF PLANS FOR SCOPE AND SPECIFICATIONS FOR THE ELECTRICAL WORK. Q HVAC GENERAL NOTES 1. SEE MECHANICAL / HVAC DRAWINGS ('M' SHEETS) IN THIS SET OF PLANS FOR SCOPE AND SPECIFICATIONS FOR THE MECHANICAL / HVAC WORK- 2 PLUMBING GENERAL NOTES 1- SEE PLUMBING ('P' SHEET) DRAWINGS IN THIS SET OF PLANS FOR SCOPE AND SPECIFICATIONS FOR THE PLUMBING WORK. 2.5 SCALE: 1/4" = V-0" m m z w w Of Z) cy w Z w a cn to 00 0 La CN o 0 Z N A L U C U .� CDCL ri c..> IV L a O C) CD MhCD o � 100 • Lo co 3 U1Z,3v)o O CD Q N w W N � o � a a � 0 U Wa C .o 0 0 V) F N v� N s ti CONTRACTOR -SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECT OF ANY DIMENSIONAL ERRORS, OMISSIONS OR DISCREPANCIES BEFORE BEGINING OR FABRICATING ANY WORK. DO NOT SCALE DRAWINGS. N 0 e- V C 3 T -3 s ti 0 0 O O z o � � W CL c J �1 ; ,iE uj Q U O Q X O W J R in 1-40 LL.. 0 Q z W ., O w Q � � QO� a.Wo �--� to .j ILo �1 OLLj _ Q ca ,Q W cu U .3 2 W V) II_ U) N N O F- 0 o ca DRAWN BJ CHECKED JRJJ DATE 09/02/03 ESCALE ASNOTED OJECT NO. H32503 FILE NAME 2503A1U SHEET A- A I- KUIV tLtVA I IUN SCALE: 1/4" EXIST, 5/8" TYPE "X" GYP. BD. @ BOTH SIDES OF STUDS_,77 CUT IN BOX — 2G @ 24" A.F.F. �— EXIST. 6" I-4" SQ. BOX METAL STUDS ® 18" A.F.F. INSERT METACAULK BOX GUARD, BY RECTORSEAL, INTO ALL ELECTRICAL BOXES IN FIRE RATED WALLS. INSERT ONTO THE INSIDE BACK WALL OF THE BOX. METACAULK BOX GUARD IS A ONE COMPONENT FIRE RATED PAD AND IS A HIGHLY INTUMESCENT FIRESTOP MATERIAL. SEE ATTACHED DATA SHEETS. 11 ELECTRICAL BOX PENETRATION DETAIL SCALE: 1" = 1'-0" ELEC—PENETRATION DESIGN NO. U465 NONBEARING WALL RATING -1 HR. SYSTEM NO. W-L-1006 (FORMERLY SYSTEM NO. 187) FRATING -2HR TRATING -0HR SECTION B-B 1. WALL ASSEMBLY -THE FIRE -RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES WALL AND PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTON FEATURES: A. STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. LUMBER SPACED 16 IN. O.C_ STEEL STUDS TO BE MIN 2-1/2 IN. WIDE AND SPACED MAX 24 IN. O.C. B. WALLBOARD, GYPSUM* - TWO LAYERS OF NOM 5/8 IN. THICK GYPSUM WALLBOARD, AS SPECIFIED IN THE INDIVIDUAL WALL AND PARTITION DESIGN. MAX. DIAM OF OPENING IS 2 IN. 2. THROUGH PENETRANTS - ONE METLIC PIPE, CONDUIT OR TUBING TO BE CENTERED WITHIN THE FIRESTOP SYSTEM. PIPE, CONDUIT OR TUB!s lip TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF METALLIC PIPE, CONDUIT OR TUBING MAY BE USED: A. STEEL PIPE - NOM 1 IN. DIAM (OR SMALLER) SCHEDULE 5 (OR HEAVIER) STEEL PIPE. A NOM ANNULAR SPACE OF 5/16 IN. IS REQUIRED WITHIN THE FIRESTOP SYSTEM. B. CONDUIT - NOM 1 IN. DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING OR RIGID STEEL CONDUIT. A NOM ANNULAR SPACE OF 5/16 IN. IS REQUIRED WITHIN THE FIRESTOP SYSTEM. C. COPPER TUBING - NOM 1 IN. DIAM (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING. A NOM ANNULAR SPACE OF 5/16 IN. IS REQUIRED WITHIN THE FIRESTOP SYSTEM. D. COPPER PIPE - NOM 1 IN. DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE. A NOM ANNULAR SPACE OF 5/16 IN. IS REQUIRED WITHIN THE FIRESTOP SYSTEM. 3. FIRESTOP SYSTEM - THE FIRESTOP SYSTEM SHALL CONSIST OF THE FOLLOWING: A. FILL, VOID OR CAVITY MATERIAL* --PUTTY - MIN 1-1/2 IN. THICKNESS OF FILL MATERIAL APPLIED WITHIN HE ANNULUS, ON BOTH SURFACES OF WALL. ADDITIONAL FILL MATERIAL TO BE INSTALLED SUCH THAT A MIN 1/8 IN- CROWN IS FORMED AROUND THE PENETRATING ITEM. NELSON FIRESTOP PRODUCTS - TYPES FSP PUTTY AND FSP FIRESTOP PUTTY PADS *BEARING THE UL CLASSIFICATION MARKING 10 PIPE PENETRATION DETAIL N.T.S. 2 4 1. FLOOR AND CEILING RUNNERS - (NOT SHOWN) CHANNEL SHAPED RUNNERS, 3-5/8 IN. WIDE (MIN), 1-1 /4 IN. LEGS, FORMED FROM NO- 25 MSG (MIN. NO. 20 MSG WHEN ITEM 4C IS USED) GLAV STEEL, ATTACHED TO FLOOR AND CEILING WITH FASTENERS SPACED 24 IN. OC MAX. 2. STEEL STUDS - CHANNEL SHAPED, 3-5/8 IN. WIDE (MIN), 1-1/4 IN. LEGS 3/8 IN. FOLDED BACK RETURNS, FORMED FROM NO. 25 MSG (MIN NO. 20 MSG WHEN ITEM 4C IS USED) GALV STEEL SPACED 24 IN. OC MAX. 3. BATTS AND BLANKETS *- (OPTIONAL) - MINERAL WOOL OR GLASS FIBER BATTS PARTIALLY OR COMPLETELY FILLING STUD CAVITY. SEE BATTS AND BLANKETS (BZJZ) CATEGORY FOR NAMES OF CLASSIFIED COMPANIES. 4. WALLBOARD, GYPSUM 5/8 IN. THICK, 4 FT. WIDE, ATTACHED TO STEEL STUDS AND FLOOR AND CEILING TRACK WITH 1 IN. LONG, TYPE S STEEL SCREWS SPACED 8 IN. OC, ALONG EDGES OF BOARD AND 12 IN. OC. IN THE FIELD OF THE BOARD. JOINTS ORIENTED VERTICALLY AND STAGGERED ON OPPOSITE SIDES OF THE ASSEMBLY. WHEN ATTACHED TO ITEM 6 (FURRING CHANNELS), WALLBOARD IS SCREW ATTACHED TO FURRING CHANNELS WITH 1 IN. LONG, TYPE S STEEL SCREWS SPACED 12 IN. OC. AMERICAN GYPSUM CO. - TYPE AG-C CANADIAN GYPSUM CO. - TYPES AR, C, IP-X2, SCX, SHX, WRC OR WRX. CELOTEX CORP. - TYPE 1 _ CONTINENTAL GYPSUM COMPANY - TYPES CG-C, CG5-5, CG6-6, CG9-9, CGTC-C. G-P GYPSUM CORP, SUB OF GEORGIA-PACIFIC CORP - TYPES 5, 9, C, GPFS6. JAMES HARDIE GYPSUM - TYPE BG-C. LAFARGE GYPSUM, A DIV. OF LAFARGE CORP. - TYPES LGFC2, LGFC2A, LGFC6, LGFC6A, LGFC-C. NATIONAL GYPSUM CO - TYPES FSK-G, FSW-G. NATIONAL GYPSUM CO -TYPES FR OR WR. PABCO GYPSUM, DIV OF PACIFIC COAST BUILDING PRODUCTS INC - TYPE PG-C_ REPUBLIC GYPSUM CO. - TYPE RG-C. STANDARD GYPSUM CORP. - SG-C TEMPLE -INLAND FOREST PRODUCTS CORP. - TYPE TG-C. UNITED STATES GYPSUM CO. - TYPE AR, C, FRX-G, IP-X2, SCX, SHX, WRC OR WRX. YESO PANAMERICANO SA DE CV - TYPE AR, C, IP-X2, SCX, SHX, WRC OR WRX. WESTROC ING. - TYPE WESTROC FIREBOARD. 4A. WALLBOARD, GYPSUM* - (AS AN ALTERNATE TO ITEM 4) - NOM 3/4 IN- THICK, 4 FT WIDE, INSTALLED AS DESCRIBED IN ITEM 4 WITH SCREW LENGTH INCREASED TO 1-1/4 IN. CANADIAN GYPSUM COMPANY - TYPE AR. UNITED STATES GYPSUM CO. - TYPE AR. YESO PANAMERICANO SA DE C V - TYPE AR. 4C. WALLBOARD GYPSUM*- (AS AN ALTERNATE TO ITEMS 4, 4A AND 46) - 5/8 IN. THICK GYPSUM PANELS, INSTALLED AS DESCRIBED IN ITEM 4 WITH TYPE S-12 STEEL SCREWS. THE LENGTH AND SPACING OF THE SCREWS AS SPECIFIED UNDER ITEM 4. CANADIAN GYPSUM COMPANY - TYPE FRX_ UNITED STATES GYPSUM CO. - TYPE FRX. 5. JOINT TAPE AND COMPOUND - VINYL, DRY OR PREMIXED JOINT COMPOUND, APPLIED IN TWO COATS TO JOINTS AND SCREW HEADS; PAPER TAPE, 2 IN. WIDE, EMBEDDED IN FIRST LAYER OF COMPOUND OVER ALL JOINTS. AS AN ALTERNATE, NOMINAL 3/32 IN. THICK GYPSUM VENEER PLASTER MAY BE APPLIED TO THE ENTIRE SURFACE OF CLASSIFIED VENEER BASEBOARD. JOINTS REINFORCED. 6. FURRING CHANNEL - (OPTIONAL -NOT SHOWN) - RESILIENT 25 MSG GALV. STEEL FURRING CHANNELS SPACED VERTICALLY MAX 24 IN. OC, FLANGE PORTION ATTACHED TO EACH INTERSECTING STUD WITH 1/2 IN. LONG TYPE S-12 PANHEAD STEEL SCREWS. NOT FOR USE WITH TYPE FRX GYPSUM PANELS. *BEARING THE UL CLASSIFICATION MARKING. NEW , CEILIt NEW GYP. OVER GA. N 16" ( EXIST WALL NEW COVE NEW Z'-11 1/2" NEUTRAL SOFFfT BOTf. 10'-0" OF STORE FRONT roP o SYSTEM NO. WL1017 (FORMERLY SYSTEM NO. 328) F RATING - 1,2 HR (SEE ITEM 3) T RATING - 0 HR L RATING AT AMBIENT - LESS THAN 1 CFM/SQ FT L RATING AT 400 F - LESS THAN 1 CFM/SQ FT SECTION A -A 1. WALL ASSEMBLY -THE 1 OR 2 HR FIRE RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY SHALL BE CON- STRUCTED OF THE MATERIALS AND IN THE MANNER DESCRIBED IN THE INDIVIDUAL U300 OR U400 SERIES WALL OR PARTITION DESIGN IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTON FEATURES: A. STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL_ STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. LUMBER SPACED 16 IN. O.C. WITH NOM 2 BY 4 IN. LUMBER END PLATES AND CROSS BRACES. STEEL STUDS TO BE MIN. 3 5/8 IN.WIDE BY 1-3/8 IN. DEEP CHANNELS SPACED MAX. 24 IN. O.C. B. WALLBOARD, GYPSUM* - NOM 5/8 IN. THICK, 4 FT. WIDE WITH SQUARE OR TAPERED EDGES. THE GYPSUM WALLBOARD TYPE, NUMBER OF LAYERS, AND SHEET ORIENTATION SHALL BE' AS SPECIFIED IN THE INDIVIDUAL WALL OR PARTITION DESIGN. DIAM OF CIRCULAR CUT THROUGH GYPSUM WALL- BOARD ON EACH SIDE OF WALL ASSEMBLY TO BE MIN. 0 IN. (POINT CONTACT) TO MAX 1 IN. LARGER THAN OUTSIDE DIAM OF FLEXIBLE METAL CONDUIT (ITEM 2) INSTALLED IN THROUGH OPEN- ING. SIDE EDGE OF CIRCULAR OPENING TO BE MIN. 3 IN. FROM NEAREST STUD IN WALL CAVITY, C. FASTENERS - WHEN WOOD STUD FRAMING IS EMPLOYED, GYPSUM WALLBOARD ATTACHED TO STUDS WITH CEMENT COATED NAILS AS SPECIFIED IN THE INDIVISUAL WALL OR PARTITION DESIGN. WHEN STEEL CHANNEL STUD FRAMING IS EMPLOYED, GYPSUM WALLBOARD ATTCHED TO STUDS WITH TYPE S SELF -DRILLING, SELF -TAPPING BULGE -HEAD STEEL SCREWS AS SPECIFIED IN THE INDIVIDUAL WALL OR PARTITION DESIGN. 2. THROUGH PENETRANTING PRODUCT* - FLEXIBLE METAL CONDUIT - NOM 4 IN. DIAM (OR SMALLER) ALUMINUM OR STEEL FLEXIBLE METAL CONDUIT+. MAX ONE FLEXIBLE METAL CONDUIT TO BE INSTALLED NEAR CENTER OF CIRCULAR OPENING IN GYPSUM WALLBOARD. FLEXIBLE METAL CONDUIT TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. AFC CABLE SYSTEMS INC. 3. FILL, VOID OR CAVITY MATERIAL* - CAULK - CAULK FILL MATERIAL FORCED INTO ANNULAR SPACE AROUND ENTIRE CIRCUMFERENCE OF THROUGH PENETRATING PRODUCT TO COMPLETELY FILL OPENING IN GYPSUM WALLBOARD LAYERS ON EACH SIDE OF THE WALL ASSSEMBLY. A MIN 5/8 IN. THICKNESS OF CAULK IS REQUIRED FOR THE 1 HR. F RATING. A MIN. 1-1/4 IN THICKNESS OF CAULK IS REQUIRED FOR 2 F RATING. MINNESOTA MINING & MFG CO - CP 25WB+ *BEARING THE UL CLASSIFICATION MARKING 9 FLEXI N.T.S. IT PENETRATION DET ATTACHED WITH POWER ACTUATED FASTNERS EXISTING ROOF DECK ri 3 5/8" (25 GA.) NEW 2 LAYERS METAL STUD BRACE 5/8" TYPE 'X' @ 4'-0" O.C. - i GYP. BD. OVER EXISTING METAL 1 '-0" - - - _ - FRAMING sus STOCK Roos NEW ACOUSTICAL CEILING NEW ACOUSTICAL �II � NEWACOUSTICAL CEILING CEILING j NEW 5/8" TYPE 'X' EXISTING STUD FRAMING 1 GYP. BD. BOTH SIDES OVER 3-5/8" 25 GA. MTL STUDS @ 16" NEW 5/8" TYPE 'X' O_C_ GYP_ BD. ONE SIDE OVER 3-5/8" 25 GA. MTL STUDS 16" O.C. NEW 4" VINYL NEW 4" VINYL COVE BASE � COVE BASE\ NEW SLAB ;�� NEW SLAB 1 _ WALL ASSEMBLY —THE 1 OR 2 HR FIRE RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY SHALL BE CON- STRUCTED OF THE MATERIALS AND IN THE MANNER DESCRIBED IN THE INDIVIDUAL U300 OR U400 SERIES WALL OR PARTITION DESIGN IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES: A. STUDS — WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. LUMBER SPACED 16 IN. O.C. WITH NOM 2 BY 4 IN. LUMBER END PLATES AND CROSS BRACES. STEEL STUDS TO BE MIN. 3-5/8 IN. WIDE BY 1-3/8 IN. DEEP CHANNELS SPACED MAX. 24 IN. O.C. B- WALLBOARD, GYPSUM* — NOM 5/8 IN. THICK, 4 FT. WIDE WITH SQUARE OR TAPERED EDGES. THE GYPSUM WALLBOARD TYPE, NUMBER OF LAYERS, AND SHEET ORIENTATION SHALL BE AS SPECIFIED IN THE INDIVIDUAL WALL OR PARTITION DESIGN. DIAM OF CIRCULAR CUT THROUGH GYPSUM WALL— BOARD ON EACH SIDE OF WALL ASSEMBLY TO BE MIN. 0 IN. (POINT CONTACT) TO MAX. 1 IN. LARGER THAN OUTSIDE DIAM OF FLEXIBLE METAL CONDUIT (ITEM 2) INSTALLED IN THROUGH OPEN— ING. SIDE EDGE OF CIRCULAR OPENING TO BE MIN. 3 IN. FROM NEAREST STUD IN WALL CAVITY. C. FASTENERS — WHEN WOOD STUD FRAMING IS EMPLOYED, GYPSUM WALLBOARD ATTACHED TO STUDS WITH CEMENT COATED NAILS AS SPECIFIED IN THE INDIVIDUAL WALL OR PARTITION DESIGN. WHEN STEEL CHANNEL STUD FRAMING IS EMPLOYED, GYPSUM WALLBOARD ATTACHED TO STUDS WITH TYPE S SELF -DRILLING, SELF -TAPPING BULGE -HEAD STEEL SCREWS AS SPECIFIED IN THE INDIVIDUAL WALL OR PARTITION DESIGN. 2_ THROUGH PENETRATING PRODUCT* — FLEXIBLE METAL CONDUIT — NOM 4 IN. DIAM (OR SMALLER) ALUMINUM OR STEEL FLEXIBLE METAL CONDUIT+. MAX. ONE FLEXIBLE METAL CONDUIT TO BE INSTALLED NEAR CENTER OF CIRCULAR OPENING IN GYPSUM WALLBOARD. FLEXIBLE METAL CONDUIT TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY, AFC CABLE SYSTEMS INC. 3. FILL, VOID OR CAVITY MATERIAL* — CAULK — CAULK FILL MATERIAL FORCED INTO ANNULAR SPACE AROUND ENTIRE CIRCUMFERENCE OF THROUGH PENETRATING PRODUCT TO COMPLETELY FILL OPENING IN GYPSUM WALLBOARD LAYERS ON EACH SIDE OF THE WALL ASSEMBLY. A MIN. 5/8 IN. THICKNESS OF CAULK IS REQUIRED FOR THE 1 HR. F RATING. A MIN. 1-1/4 IN THICKNESS OF CAULK IS REQUIRED FOR 2 F RATING. MINNESOTA MINING & MFG. CO - CP 25WB+ *BEARING THE UL CLASSIFICATION MARKING 4. MIN. 26 GA. METAL STUD SCREWED TO FACE OF FIRE WALL THROUGH THE GYP. BD. FINISH INTO THE METAL STUDS FROM STUD TO STUD AT PENETRATION ONLY. 5. CABLE STRAP ATTACHED TO METAL STUD SUPPORT. g PIPE PENETRATION DETAIL N.T.S. .145 P.A.F. @ 3-5/8" 20GA, MTL. STUDS @ 16" O.C. ZAT OVERHEAD COILING GRILLE ONLY. � I EXISTING METAL.10 STUD FRAMING TO REMAIN—�, NEW 5/8" TYPE 'X' GYP. BD NEW 5/8" TYPE 'X' GYP. BD. BOTH . SIDES OVER 3-5/8" 25GA. MTL. STUDS @ 16" O.C. NEW 12" 160A. DOUBLE STUD HEADER NEW 5/8" TYPE I I 'X' GYP. BD_ BOTH SIDES OVER j 3-5/8" 25GA. MTL. STUD JOIST @ 16" O.C. I I REMOVE j EXISTING WALL►�I NEW FRAME LESS STOREFRONT GLAZING SYSTEM LEASE LINE EXISTING METAL STUD FRAMING TO NEW 3-5/8"� 20GA. MTL. STUD NEW 5/8" TYPE BRACE @ 4'-0" 'X' GYP. BD. BOTH O.C. SIDES OVER OVERHEAD COILING 3-5/8" 25GA, GRILLE ASSEMBLY MTL STUDS @ 16" W/ CRANK 0_C_ OPERATION NEW 12" 16GA. DOUBLE STUD HEADER '- " 1 NEW .145 P.A.F. @ 1 ACOUSTICAL 12" O.C. CEILING REMOVE EXISTING WALL t I NEW FRAME LESS STOREFRONT GLAZING! 1 SYSTEM LEASE LINE -ry .145 P.A.F. @ 12" O.C. SYSTEM NO. W-L-1001 (FORMERLY SYSTEM NO. 147) F RATINGS-1,2,3 AND 4 HR (SEE ITEMS 2 AND 3) T RATINGS-0,1,2,3 AND 4 HR (SEE ITEM 3) L RATING AT AMBIENT —LESS THAN 1 CFM/SQ. FT_ L RATING AT 400 F—LESS THAN 1 CFM/SQ. FT. SECTION A -A 1. WALL ASSEMBLY -THE 1,2,3 OR 4 HR FIRE -RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER DESCRIBED IN THE INDIVIDUAL U300 OR U400 SERIES WALL OR PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES: A. STUDS -WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS (MAX 2 H FIRE RATED ASSEMBLIES) OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. LUMBER SPACED 16 IN. O.C. WITH NOM 2 BY 4 IN. LUMBER END PLATES AND CROSS BRACES. STEEL STUDS TO BE MIN. 3-5/8 IN. WIDE BY 1-3/8 IN. DEEP CHANNELS SPACED MAX 24 IN. O.C. B. WALLBOARD, GYPSUM*-NOM 1/2 OR 5/8 IN, THICK, 4 FT. WIDE WITH SQUARE OR TAPERED EDGES. THE GYPSUM WALLBOARD TYPE, THICKNESS, NUMBER OF LAYERS, FASTENER TYPE AND SHEET ORIENTA- N L BE AS SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES DESIGN IN THE UL FIRE RES- ISTANCE DIRECTORY. MAX DIAM OF OPENING IS 13-1/2 IN. 2. PIPE OR CONDUIT-NOM 12 IN. DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE, NOM 12 IN. DIAM (OR SMALLER) SERVICE WEIGHT (OR HEAVIER) CAST IRON SOIL PIPE, NOM 12 IN. DIAM (OR SMALLER) CLASS 50 (OR HEAVIER) DUCTILE IRON PRESSURE PIPE, NOM 6 IN. DIAM (OR SMALLER) STEEL CONDUIT, NOM 4 IN. DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING, NOM 6 IN. DIAM OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING OR NOM 1 IN. DIAM (OR SMALLER) FLEXIBLE STEEL CONDUIT. WHEN COPPER PIPE IS USED, MAX F RATING OF FIRESTOP SYSTEM (ITEM 3) IS 2 H. STEEL PIPES OR CONDUITS LARGER THAN NOM 4 IN. DIAM MAY ONLY BE USED IN WALLS CONSTRUCTED USING STEEL CHANNEL STUDS. A MAX OF ONE PIPE OR CONDUIT IS PERMITTED IN THE FIRESTOP SYSTEM. PIPE OR CONDUIT TO BE INSTALLED NEAR CENTER OF STUD CAVITY WIDTH AND TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. 3. FILL, VOID OR CAVITY MATERIAL* -CAULK-CAULK FILL MATERIAL INSTALLED TO COMPLETELY FILL ANNULAR SPACE BETu,'EEN PIPE, OR CONDUIT AND GYPSUM WALLBOARD AND WITH A MIN 1/4 IN. DIAM. BEAD OF CAULK APPLIED TO PERIMETER OF PIPE OR CONDUIT AT ITS EGRESS FROM THE WALL, CAULK INSTALLED SYMMETRICALLY ON BOTH SIDES OF WALL ASSEMBLY, THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS DEPENDENT UPON THE HOURLY FIRE RATING OF HE WALL ASSEMBLY IN WHICH IT IS INSTALLED. AS SHOWN IN 'HE FOLLOWING TABLE. THE HOURLY T RATING OF THE FIRESTOP SYSTEM IS DEPENDENT UPON THE TYPE OR SIZE OF THE PIPE OR CONDUIT AND THE HOURLY FIRE RATING OF THE WALL :ASSEMBLY IN WHICH IT IS INSTALLED, AS TABULATED BELOW: MAX PIPE ANNULAR F T OR CONDUIT SPACE, RATING, RATING, DIAM, IN IN HR HR 1 0 TO 3/ 16 1 OR 2 0+, 1 OR 2 1 1/4 TO 1/2 3 OR 4 3 OR 4 4 0 TO 1/4 1 OR 2 0 4 0 TO 1-1 2# 1 OR 2 6 1 4 TO 1/2 3 OR 4 0 12 3 16 TO 3/8 1 OR 2 0 +WHEN COPPER PIPE IS USED, T RATING IS 0 H. TTHOETMIN THICKNESS�OF HE GYPSUM WALLBOARD ISNULAR SPACE APPLIES ONLY HEN 5/8TIN.EFOR 15HRBRATEDULK IS USED AND WAL S AND 1-1/40rLY N IN. OR 2 HR RATED WALLS. MINNESOTA MINING & MFG. CO. - CP 25WB+. *BEARING THE UL CLASSIFICATION MARKING NEW 5/8" TYPE 'X' GYP. BD NEW 3-5/8" 20GA. MTL. STUD BRACE @ 4'-0" O.C. NEW ACOUSTICAL CEILING PIPE PENETRATION DETAIL N.T.S. -EXISTING STRUCTURE TO REMAIN NEW 5/8" TYPE 'X' GYP. BD NEW ACOUSTICAL CEILING\ OL .145 P.A.F. @ 12" O.C- REMOVE EXISTING WALL�� NEW FRAME LESS STOREFRONT GLAZING SYSTEM LEASE LINE .145 P.A. F. @ 12" O.C. EXISTING METAL STUD FRAMING TO REMAIN m z w w c� w z W d Z Z O O (f) V) O rn N O Q z cV Q � "1 O O rQ o ' n a V1 U .2 Mo J Q I � Q I UJ Q r, 00 1 w = r` O O 4 U W o .� NLL � � W � H _c� �4 v a� CONTRACTOR—S LL VERIFY ALL ,CONDITIONS AND DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECT OF ANY DIMENSIONAL ERRORS, OMISSIONS OR DISCREPANCIES BEFORE BEGINING OR FABRICATING ANY WORK. DO NOT SCALE DRAWINGS. a! �1 Cn ZQ _1 IW —J � W —" W U � N � C) LaO Z Z r�jW®0 0 I T_] a Ck� a O NLdo w_j :z E4 0 J �1� Z(j) aw W w V) _OU � W H Z V N 0 n. DRAWN BJ CHECKED JRJJ DATE 09/02/03 SCALE AS NOTED PROJECT NO. H32503 FILE NAME 2503A3U SHEET A-3 6 EXISTING FIREWALL DESIGN N.T.S. 0�nALSCTIOE 1/2" = 1'-0" 2503WSF-2.DWG @�IASCTIO1/2" = 1'-0" 2503WSF-2.DWG (DIA LL SECTION 1/2" = 1'-0° 2503WSF-2.DWG 2A WALL SECTION SCALE 1/2" = 1'-0' 2503WSF.DWG 2 WALL SECTION SCALE 1/2" = 1'-0" 2503WSF.DWG 0�nA LL SECTION E 1/2" = 1'-0" 2503WSF.DWG 15000 - GENERAL CONDITIONS FOR PLUMBING WORK 1.1 Materials and workmanshlp A. Products and materials shall meet or exceed the quality or requirements specified or shown on the drawings. B. Provide products and materials, which the manufacturer has certified as appropriate to the applications shown on the drawings and specifications, C. Provide products and materials, which are supported by convenient, parts availability and servicing. D. Workmanship shall be in all respects of the highest quality and all construction shall be done according to the best practice of the trade. All systems shall be made complete and operational in first class working order. Furnish all necessary labor and materials to construct a complete system. 1.2 Obtain all permits and inspections required by law for the completion of the work. Cost of the required permits and Inspections shall be paid by the contractor. The Contractor shall obtain and pay For all Certificates of Approval, which must be obtained prior to final acceptance of the Job. All materials and labor furnished by the Contractor shall be in strict accordance with the rules and regulations of the state and municipality, utility companies, Florida Building Code - 2001, National Electric Code (NEC) and the National Fire Protection Association (NFPA), 1.3 Provide the owner with the following prior to final application for payment: A. Parts list for each piece of equipment. B. One bound set of approved shop drawings. C. One bound set of operating instructions and maintenance schedules for each piece of equipment. D. Copies of all warranties for each piece of equipment. 1A Guarantees and warranties A. Guarantee all labor and material furnished For a period of one year extending from the time of final acceptance of the building. The guarantee shall cover the repair or replacement without additional cost to the owner for any defective material or faulty workmanship. B. Provide warranties for each piece of major equipment. Warranties shall be Included with the owner's final documents. 15100 - PLUMBING 1.1 General A. Work shall Include but not be limited to the following: Provide all labor, materials, services, equipment and appliances required for the fabrication and installation of the plumbing system, as Indicated on the design drawings and as outlined in these specifications. B. Equipment and design of systems Indicated on the design drawings and within these specifications shall be considered as 'specified standard' of quality. Substitutions shall be of equal quality. C. The entire system and all components listed herein shall meet all state, county and local codes and ordinances in every respect. The contractor shall obtain all required permits, inspections and pay all f ees. D. All equipment, etc, shall be new unless otherwise noted, and as specified free of defects as shown on the drawings and as indicated in these specifications. All electrical powered equipment shall be U.L. or E.T.L. Listed. E. All materials shall be fabricated and Installed in a neat and professional manner with the coordination of all involved trades to avoid interferences and delay due to lack of coordination. No allowances will be made for rework due to coordination difficulties or interferences between involved trades, 1.2 Submittals A. Submit for engineer's approval, shop drawings, and manufacturer's data for all new equipment and fixtures prior to purchase and or Fabrication, Shop drawings for equipment requiring electric power or control wiring connections shall Include complete wiring diagrams. B. The contractor shall provide the engineer two (2) sets of complete plumbing as -built drawings at the time of substantial completion. As -bunts shall be provided on reproduclble vellum and AutoCAD drawing files [if possible]. As -built drawings shall consist of an accurate 'as -built' record of the Installed work. Project will not be complete until accurate as -bunts are delivered. C. Provide complete maintenance manuals (3 required) on all new equipment. Organize operating and maintenance data into suitable sets of manageable size. Bind property Indexed data in individual, heavy-duty, 2-Inch, 3-ring vinyl -covered binders with pocket folders for folded sheet information. Mark appropriate identification on front and spine of each binder, Include the following type of Information. The Information will be turned over to the owner at time of substantial completion: 1. Operating and maintenance instructions 2. Spare parts list 3. Copies of warranties 4. Wiring diagrams 5. Inspection reports and approvals 6. Shop drawings and product data 1.3 Access panel A. Contractor shall provide hinged access doors (min, 12'x12') for valves, etc. where floors, walls and ceiling must be penetrated to access mechanical systems, Finish shall be coordinated through the architect to match surrounding finishes. 1.4 Cleaning, testing and adjusting A. The contractor, at his expense, shall clean, repair, adjust, check, A. balance, and place in service the various systems herein specified with their respective equipment, accessories and piping. The contractor shall furnish all labor, materials, equipment, and tools required to perform tests required by these specifications and by the governing authorities. B. No work shall be covered or concealed until properly inspected B. and tested. C. All domestic water piping systems shall be tested for absolute C, tightness by subjecting the system to a hydrostatic pressure of 150 PSI gauge or 50 PSI over working pressure, whichever is greater for a period of not less than eight (8) hours. All leaks shall be repaired and the hydrostatic test reapplied until, for an eight (8) hour period, no leaks can be found while the system Is subject to the test pressure. Soil pipe and condensate drains shall be tested by temporarily plugging all outlets and filling the system with water to the level of the highest vent stack, The system must be Inspected and all leaks repaired and the test repeated until the water level does not decrease for a period of 24 hours. VACUUM BREAKER-\ /-'HEAT TRAP IN ACCORDANCE / WiTH ENERGY CODE DIELECTRIC UNION (TYP.) TO SYSTEM REFER P & T REUEF PIPING FULL SIZE TO PLANS FOR SIZES f TO MOP SINK_ TERMINATE 6" ABOVE SINK, MOUNT WATER HEATER ON WALL WATER MOUNTING BRACKET 8'-0" A.F.F. EXPANSION TANK HEATER ET-1 SEE 2" SCHEDULE ROUTE THE WATER HEATER DRAIN PAN DRAIN LINE FULL SIZE TO MOP BASIN. WATER HEATER DRAIN PAN 24' X 24" X 2" HIGH 1" (24 GA. GALV, STEEL) ALL JOINTS WATERTIGHT DRAIN CONNECTION TO PAN SHALL BE MADE WATER TIGHT AND FLUSH WITH BOTTOM OF PAN. NOT TO SCALE X4 TER ffT4 Z 'R d" R41W P-4N DEE4IL P0012L 1.5 Hangers and supports A. Provide all necessary, pipe supports, hangers, rods, clamps and attachments to properly install and support piping and equipment from the building structure, B. Provide any angle iron or unistrut and suspension rods required to install equipment and piping. 1.6 Water supply system A. Extend water service as Indicated on design drawings. Provide shock absorbers and vacuum breakers where required. B. Pipe and fittings above ground - type L hard copper and wrought copper fittings. Pipe and fittings below ground - type K, soft copper. Valves - ball valves - all bronze, rising stem, double wedge taper seat, 125 PSIG pressure. C. Insulation shall be fire rated for use in return air plenum. 1.7 Connections to miscellaneous equipment A. Rough -in and connect water, waste, and vent to complete the installation of equipment listed on the drawings. B. Plumbing fixtures shall be provided complete as shown on the drawings with all required supply, waste, soil, and vent connections, together with all fittings, supports, fastening devices, cocks, valves, and traps. C. All fixtures shall have stop valves on all water connections. All exposed metal trim on all fixtures shall be polished chromium plated. All exposed pipes extending from wall shall have chromium plated brass escutcheon mounted against wall. Exposed PVC piping and p-traps are unacceptable. D. The plumbing fixtures shall be roughed -in accordance with manufacturer's 'rough -in information'. Provisions for mounting wall fixtures shall be made while the wall is being built, 1.8 Drainage system 1. Pipe slope: 1. 2-1/2 inch diameter and less shall be Installed with a fall of not less than 1/4 inch per foot. 2. 3 inch diameter or larger shall be installed with a fall not less 2. Than 1/8 Inch per foot. B. Pipe and fittings: 1. Drain, waste and vent piping located in fire rated wall assemblies and return air plenums shall be service -weight cast iron with no/hub or bell and spigot fittings. 2, Provide cleanouts every 75 feet, at changes in direction, at base of down spouts and at base of soil and waste stacks. 1.9 Execution A. All locations of equipment, piping, etc, indicated on the drawings are diagrammatic and shall be followed as closely as possible to the plans, subject to building construction and interferences with other trades. All work shall be installed to ensure maximum headroom, balanced operation and suitable aesthetic appearance. Contractor is responsible for any Field measurements required to provide an approved and functional Installation, B. Not all components required for a complete Installation are shown on these drawings. Refer to equipment installation instructions, schedules and applicable codes for additional information, including required connection locations, types and sizes, C, Provide Isolation valves and unions at all equipment and as Indicated on drawings. D. Contractor shall be responsible for furnishing and installing adequate and proper insulation and moisture -seal in a manner that will permanently prevent the accumulation of any objectionable moisture on the exterior of condensate drain piping, or other parts of the system. The contractor shall correct the cause of any condensation and fully repair, without cost the owner, any damages to building surfaces, furnishings or equipment caused by condensation from this system, for the full period of the guarantee. E. Perform all work necessary to prepare the structure for the installation of the work. F. All holes, openings and damaged materials created during construction shall be repaired and Finished by experienced workmen. Provide all roof, wall and floor penetrations required to complete Installation or work (maintain fire rating of existing structure). All penetrations shall be patched and finished to match surrounding surfaces and finishes. All equipment or pipe penetrations through wall, roof and floors shall be sleeved and sealed so as to be water and air tight, END OF SECTION 15100 PLUMBING FIXTURE SCHEDULE REF ITEM MFR & CAT. NO. WASTE TRAP VENT H_W. C.W. L-1 WALL HUNG LAVATORY - ADA: AMERICAN STANDARD 2 1 1/4 1 1/4 1/2 1/2 VITREOUS CHINA, 18" X 15" 0373.027 PERFORATED STRAINER WITH 1 1/4" McGUIRE 155-WC OFFSET TAILPIECE, CHROME PLATED 3/8" SUPPLY W/ANGLE McGUIRE 158WC STOP & WROT ESCUTCHEON OFFSET, CHROME BRASS P-TRAP, 17 GA. WITH McGUIRE 8902 ESCUTCHEON WALL MTD_ CARRIER W/HANGER PLATE, JOSAM OR ZURN CONCEALED ARMS. FAUCET WITH AERATOR, 4" WRIST BLADES SYMMONS S-90-FR 0.5 GPM FLOW, ON 4" CENTERS MB-1 SERVICE SINK: FIAT MSB-2424 3 3 2 1/2 1/2 ONE-PIECE CONSTRUCTION, 24" X 24' X 10 FLOOR MOUNTED TYPE. FAUCET WITH PAIL HOOK AND HOSE END, FIAT 830-AA VACUUM BREAKER, INTEGRAL STOPS HOSE AND HOSE BRACKET FIAT 832-AA MOP HANGAR, 24" X 3", 18 GA FIAT 889-CC VINYL BUMPER GUARD FIAT E-77-AA SILICONE SEALANT FIAT 833-AA WC-1 WATER CLOSET - ADA AMERICAN STANDARD 3 INT. 2 - 1/2 VITREOUS CHINA, FLUSH TANK, SIPHON 2108.408 JET, ELONGATED BOWL, 12' ROUGHING, FLOOR MOUNTED, WATER SAVER TYPE, SEAT 19" A.F.F., WHITE SOLID PLASTIC SEAT, OPEN FRONT CHECK HINGE, OLSONITE 95 CHROME PLATED 3/8" SUPPLY W/ANGLE STOP AND WROT. ESCUT. McGUIRE 166 PL UffBING L'QUZP1 .EyV_T ,S'CILE ULL' REF. ITEM MANUFACTURER & CAT. NO, REMARKS EWC-1 ELECTRIC WATER COOLER ELKAY EHFA-8 MOUNT W/BUBBLER 36" A.F.F. FCO FLOOR CLEANOUT JOSAM 56064-14 W/CARPET COVER OR ROPRIATE COVER WH-1 ELECTRIC WATER HEATER LOCHINVAR JRJO12K 12 GAL, 450OW, 208V, 1 PH J08 - K.3 - J.8 - PARTIAL SANITARY PLAN SCALE: 3/16" = V-0" 0 4 8 10 (FEET) 20 GRAPHIC SCALE )e 7 CONNECT TO EXIST. VENT \ �_EXIST_ 4" VENT i i \ ,,,Q1�—EXIST. 4" SAN.NEW \\ q \ FCO l-' CONNECT TO EXIST. SAN. \ '--2' VENT 4 \ FCO \\\ r e_1-1/4 i l 2--� �i 1-1/4��\ EWC 1 i 2--� L=1 ��� MB-1 WC-1 SANTARY RISER DIAGRAM NOT TO SCALE PARTIAL WATER PLAN SCALE: 3/16" = 1'-0" :w7mm7mmmmmm� 0 4 8 10 (FEET) 20 GRAPHIC SCALE i i /2 1 1/2 WC-1 I ' EEWC-1 1 WA TER RISER DIAGRAM NOT TO SCALE 3/4 NOTE: THE SPACE ABOVE THE CEILING IS A RETURN AIR PLENUM. ALL PIPING SHALL BE CAST IRON OR COPPER. NATIONAL ENGINEERING C ORP, Consulting Engineers R CeA of AutL 1 6= 220 Live Oaks Boulevard, Casselberry, n 32707 407/539-3400 Jemee X. Fowler, &., PS, / 4W71 03032 ©2M N'UOW E:9'ftd-9 CO'P� All MOts Re$med 9-5-03 F u7 w 0 z U 0 w V) w :D wr v7 z W 0 `n' w CK � 0 n 0 1-1 00 ``'' a 0 0 C:) N = V T ) Q N W E.. oV E �� 0 O o0 CL C n w n Oo Mho 3 r ri CD C) o a f w o r, °° �NF0n � ZLLJr. Q E-4 c::)�z o n W �� �N a � 0 .Li- 0 o U O r CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE AND j NOTIFY THE ARCHITECT OF ANY DIMENSIONAL ERRORS, OMISSIONS OR DISCREPANCIES BEFORE BEGINING OR W FABRICATING ANY WORK. DO NOT SCALE DRAWINGS. 0 Ca 0 C V t 4V N 0 � W V) C) Z -J W v °- z < _J LLJ w, � O O r G7 W —1 ® aZL� Z p� w a o � �o� U N a O� � o L.i O Q Z a W o I) a O iE W ry o� D�4 v z 0 0 Q r o V DRAWN BAV CHECKED JMF DATE 09/02/03 SCALE AS NOTED PROJECT NO. H32503 FILE NAME 3032-P1 SHEET DIVISION 15000 -- MECHANICAL 15000 - GENERAL CONDITIONS FOR MECHANICAL WORK 1.1 Materials and workmanship A. Products and materials shall meet or exceed the quality or requirements specified or shown on the drawings. B. Provide products and materials, which the manufacturer has certified as appropriate to the applications shown on the drawings and specifications. C. Provide products and materials, which are supported by convenient, parts availability and servicing. D. Workmanship shall be in all respects of the highest quality and all construction shall be done according to the best practice of the trade. All systems shall be made complete and operational in first class working order. Furnish all necessary labor and materials to construct a complete system. 12 Obtain all permits and inspections required by law for the completion of the work. Cost of the required permits and inspections shall be paid by the contractor. The Contractor shall obtain and pay for all Certificates of Approval, which must be obtained prior to final acceptance of the job. All materials and labor furnished by the Contractor shall be in strict accordance with the rules and regulations of the state and municipality, utility companies, Florida Building Code - 2001, National Electric Code (NEC) and the National Fire Protection Association (NFPA). 1.3 Provide the owner with the following prior to final application for payment: A. Parts list for each piece of equipment. B. One bound set of approved shop drawings. C. One bound set of operating instructions and maintenance schedules for each piece of equipment. D. Copies of all warranties for each piece of equipment_ 1.4 Guarantees and warranties A. Guarantee all labor and material furnished for a period of one year extending from the time of final acceptance of the building. The guarantee shall cover the repair or replacement without additional cost to the owner for any defective material or faulty workmanship. B. Provide warranties for each piece of major equipment. Warranties shall be included with the owner's final documents. 15300 - HEATING, VENTILATING AND AIR-CONDITIONING 1.1 General A. Provide all labor, materials, services, equipment, and appliances required for the fabrication and installation of mechanical systems including heating, ventilating, air-conditioning, and various systems as indicated on the design drawings and as outlined in these specifications. B. Equipment and design of systems indicated on the design drawings and within these specifications shall be considered as "specified standard" of quality. Substitutions shall be of equal quality. C. The entire system and all components listed herein shall meet all state, county, and local codes and ordinances in every respect. The contractor shall obtain all required permits, inspections and pay all fees. D. All equipment, etc. Shall be new unless otherwise specified, free of defects as shown on the drawings, and as indicated in these specifications. E. All materials shall be fabricated and installed in a neat and professional manner with the coordination of all involve trades to avoid interferences and delay due to lack of coordination. No allowances will be made for rework due to coordination difficulties or interferences between involved trades. 1.2 Submittals A. Submit for engineer's approval, shop drawings, and manufacturer's data for all new equipment and Fixtures prior to purchase and/or fabrication. Submittal package for WAG equipment shall also include Qualifications and certifications of proposed test and balance subcontractor. HVAC submittals will not be reviewed without test and balance documentation. Qualifications of multiple test and balance Contractors is acceptable (to accomplish competitive bidding of work). Shop drawings for equipment requiring electric power or control wiring connections, shall include complete wiring diagrams. B. Contractor shall provide the engineer two (2) sets of complete HVAC as -built drawings at the time of Substantial completion. As-builts shall be provided on reproducible vellum and AutoCAO drawing files (if possible). As -built drawings shall consist of accurate "as -built' records of the installed work The project will not be complete until accurate as-builts are delivered. C. Maintenance manuals Provide complete maintenance manuals (3 required) on all new equipment. Organize operating and Maintenance data into suitable sets of manageable size. Bind properly indexed data in individual, heavy- Duty, 2-inch, 3-ring vinyl -covered binders with pocket folders for folded sheet information. Mark appropriate identification on front and spine of each binder. Include the following types of information. The information will be turned over to the owner at time of substantial completion: 1. Operating and maintenance instructions 2. Spare parts list 3. Copies of warranties 4. Wiring diagrams 5. Inspection reports and approvals 6. Shop drawings and product data 1.3 Training services A. Thoroughly instruct the owner's personnel during normal working hours on start-up and shut -down procedures, Troubleshooting procedures, servicing and preventative maintenance schedules and procedures. Review With the owner's personnel the data contained in the operating and maintenance manuals. Schedule the Training with the owner. Provide at least 7-days prior notice to architect/engineer. 1.4 System identification A. Provide identification labels on or near each piece of major equipment and each operational device and Disconnect. The labels shall be constructed of engraved plastic laminate sign or plastic equipment Marker permanently secured to equipment. The lettering shall be a minimum of 1/2 inch high for equipment Name and 3/8 inch for equipment information. 1.5 Hangers and supports A. Provide all necessary ductwork, pipe supports, hanger rods, clamps and attachments to properly install and support ductwork, piping and equipment from the building structure. Provide any angle iron or unistrut and suspension rods required to install equipment, piping and Ductwork B. All supports exposed to outdoors shall be cleaned, primed and painted to prevent rusting. Finish color as selected by owner. C. The use of baling wire or perforated metal strapping is not acceptable for supports. 1.7 Air distribution equipment A. Furnish supply air diffusers and return air grilles as schedules on the design drawings. Metal-aire or Price may be substituted as an equal. B. Grilles, registers, and diffusers shall be furnished as scheduled on the design drawings and shall be all B_ Steel construction. Air distribution shall not exceed NC-30 noise criteria as defined in the latest ASHRAE guide. 1.8 Ductwork A. Materials: galvanized steel of gauges conforming to latest edition of SMACNA standards based on 1" w.ga. pressure unless specifically noted otherwise on the drawings. The galvanized duct coating is to be G-90. All dimensions are inside net free area. B_ Adjustable splitters and dampers shall be installed in every split and branch duct and shall be provided with locking quadrants on exposed or in accessible areas of the duct for ease or operation. Elbows or changes in duct direction greater than 45 degrees shall be fitted with air turns consisting of Curved airfoil blades or vanes, which will permit the air to make abrupt turns without appreciable Turbulence. C. Flexible ductwork shall be acoustical low-pressure type with interior liner, metal helix, fiberglass Insulation with an R-value of 6.0 or greater, and copolymer seamless outside sleeve. The entire flexible Duct assembly shall be listed in accordance with UL-181 class 1 air duct material. The maximum length of any flex duct shall be 8'-0". Flexible ductwork shall meet the Florida model energy efficiency code. 1.9 Fire safety controls A_ Install smoke detector furnished by Division 16 in supply and return air ducts. Detector shall shut unit off when activated. B. Provide fire stat in return air of unit. Fire stat to shut unit off when activated. 2.0 Vibration isolation A. All blower units and vibrating type equipment shall be properly fitted with Mason Industries vibration Isolation equipment sized in accordance with equipment weight and duty. B. Provide flexible connectors at all supply and return connections to air conditioning equipment consisting of Heavy canvas or neoprene fabric with airtight seams and connections to the equipment. 2.2 Access doors A. Fumish in ductwork as indicated and wherever necessary for proper access to all instruments, Controls, fire dampers motorized dampers and equipment and for convenient inspection, maintenance and Replacement of same. Size to be ample for usage. Openings to be reinforced on all sides with material or Ductwork in which doors are installed. B. Hardware - use vent lok hardware throughout. All doors to be hinged with brass pin hinges and with Quick opening latches as follows: 1. Reach -in doors to be 18' high. 2. Two (2) #150 hinges w/one #90 latch. C. Access doors (hard surfaces) Contractor shall provide hinged access doors (min. 12"x12� for dampers, valves, etc. Where floors, walls, and ceilings must be penetrated to access mechanical systems. Finish shall be coordinated through the Architect or owner's representative to match surrounding finishes. Fire rated access doors in fire Rated walls or ceilings shall bear a U.L Label for fire rating requirement. 2.3 Insulation A. Shall be as manufactured by Owen -Corning, Manville, Pittsburgh Corning, Armstrong, or approved equal. Insulation sundries and adhesives shall be manufactured by Benjamin Foster, Childers, Vimasco, or Approved equal. B. Insulate all sheet metal ductwork except exhaust ductwork externally with 2" thick (R-6 minimum) Manville R series microlite type-100 insulation or approved equal. Insulation to have fsk facing and UL fire hazard Classification of: flames spread 25, smoke developed 50, fuel contributed 50. Install per SMACNA, Florida Model energy efficiency code and manufacturer's recommendations. C. Contractor shall be responsible for furnishing and installing adequate and proper insulation and Moisture -seal in a manner that will permanently prevent the accumulation of any objectionable moisture On the exterior of air-conditioning units, refrigerant piping, condensate drain piping, air ducts or other Parts of the system. Contractor shall correct the cause of any condensation and fully repair, without Cost to the owner, any damages to building surfaces, furnishings or equipment caused by condensation from this system, for the full period of the guarantee. 2.4 Testing A. Adjust the air-conditioning systems, ventilating systems, fans, etc. To deliver not less than the required Air quantity with quantities in excess to be subject to the approval of the engineer if found not have Objectionable effects such as noise, drafts, or motor overloads. B. Prior approval by the engineer of testing and balancing contractor is required. See the shop drawings and submittal section. Test and balance reports by non -approved contractors will be rejected. C. This contractor shall provide three (3) copies of a test and balance report to the engineer at time of Substantial completion inspection. The test and balance report shall be prepared by a contractor Certified by Associated Air Balance Council, National Environmental Balancing Bureau or a Professional Engineer registered in the state of Florida. D. The test and balance report shall be typewritten and contain the following data: 1. Date, time, weather, when test taken. 2. Air capacities at each unit including outside air. (Entering and leaving db/wb) 3. Static pressure through units and unit components. 4. Motor operating voltage and amperage. 5. Drive types, sizes and speed range. 6. Identification of all air terminal devices with design cfm and actual cfm. E. Additionally, systems drawings clearly marked to identify location of equipment and air devices tested shall be provided along with the written test and balance report 2.5 Execution A. All locations of equipment, ductwork, piping, etc. Indicated on the drawings are diagrammatic and shall be Followed as closely as possible to the plans subject to building construction and interferences with Other trades. All work shall be installed to ensure maximum headroom, balanced operation and suitable Aesthetic appearance. Contractor is responsible for any field measurements required to provide an Approved and functional installation. B. Not all components required for a complete installation are shown on these drawings. Refer to Equipment installation instructions, schedules and applicable codes for additional information, including required connection locations, types and sizes. C. Contractor shall be responsible for furnishing and installing adequate and proper insulation and Moisture -seal in a manner that will permanently prevent the accumulation of any objectionable moisture On the exterior of air-conditioning units, refrigerant piping, condensate drain piping, air ducts or other Parts of the system. Contractor shall correct the cause of any condensation and fully repair, without cost to the owner, any damages to building surfaces, furnishings or equipment caused by condensation from this System for the full period of the guarantee. D. All penetrations shall be patched and finished to match surrounding surfaces and finishes. All equipment or pipe penetrations through walls, roofs and floors shall be sleeved and sealed so as to be water and airtight. E. Cleaning testing and adjusting: the contractor, at his expense, shall clean, repair, adjust, check, balance, and place in service the various systems herein specified with their respective equipment, accessories and piping. He shall furnish all labor, materials, equipment, and tools required to perform tests required by these specifications and by the governing authorities. F. No work shall be concealed until properly inspected and tested. END OF SECTION 15300 AIR DISTRIBUTION EQUIPMENT SCHEDULE SYM I MANUF. - CAT. NO. I TYPE TTROW DIR. I NECK I FRAME I REMARKS A TITUS - TMS (FULL FACE) CD I 4-WAY ON DWGS 24/24 B TITUS - TMS (FULL FACE) CD 4-WAY ON DWGS 12/12 C I TITUS - 350RL RAR N/A 22/22 24/24 LEGEND: CD = CEILING DIFFUSER ER = EXHAUST REGISTER RAR = RETURN AIR REGISTER SWR = SIDEWALL REGISTER OBD = OPPOSED BLADE DAMPER CAL - OUTSIDE AIR LOUVER NOTES: 1. PROVIDE ALL CEILING DEVICES WITH PROPER FRAME STYLE TO MATCH CEILING TYPE AS CALLED FOR BY ARCHITECT. 2. ALL DEVICES SHALL BE PROVIDED WITH FINISH TO MATCH CEILING OR WALL (USUALLY WHITE). MECHANICAL CONTRACTOR SHALL COORDINATE FINISHES AS CALLED OUT ON ARCHITECTURAL DRAWINGS. 3. ALL AIR DIFFUSERS SHALL BE 4-WAY THROW UNLESS NOTED OTHERWISE OR SHOWN ON PLANS WITH DIRECTIONAL ARROWS. 4. PROVIDE OPPOSED BLADE DAMPERS D_qLY WHERE INDICATED ON SCHEDULE. LAY IN LAY IN VA V BOX SCHEDULE BASIS OF DESIGN - ENVIRO-TEC MODEL I SDR MARK I SIZE I MAX CFM I MIN CFM LAY IN, OBD VAV-1 12 1680 0 VAV-2 14 2520 1 0 VAV-3 10 985 0 NOTES: 1. ALL VAV BOXES SHALL BE PROVIDED WITH CONTROLLERS WHICH ARE COMPATIBLE WITH JOHNSON CONTROLS 'METASYS' ENERGY MANAGEMENT SYSTEM. 2, TERMINAL UNIT MANUFACTURER SHALL MOUNT, WIRE, AND/OR PIPE ALL TERMINAL UNIT CONTROLS, INCLUDING DAMPER ACTUATOR AND TERMINAL UNIT CONTROLLER FURNISHED BY THE CONTROL CONTRACTOR AND PER THE MANUFACTURER'S INSTRUCTIONS. THE TERMINAL UNIT MANUFACTURER SHALL FURNISH ALL TRANSFORMERS, RELAYS, AIRFLOW RINGS, AND ENCLOSURES. DAMPER ACTUATORS SHALL BE MOUNTED TO DAMPER SHAFTS AND FACTORY TESTED TO ASSURE PROPER ACTUATOR AND DAMPER POSITION IN THE FULL OPEN AND CLOSED POSITIONS. VENTILA TION EQUIPMENT SCHEDULE MARK EF-I AIR FLOW ( CFM) 95 EXTERNAL STATIC PRESS. ( IN.WTR.) 0.15 TYPE CENTRIFUGAL MOUNTING CEILING FAN DRIVE DIRECT RPM 1309 HP OR WATTS 55 WATTS VOLT/O 120/1 MOTOR RPM 1309 CONTROL TIME DELAY SWITCH AREA SERVED TOILET MANUFACTURER COOK MODEL # GC-140 APPLICABLE NOTES ALL NOTES: 1. PROVIDE BACKDRAFT DAMPER. 2. PROVIDE INTEGRAL DISCONNECT SWITCH. 3. FAN WILL BE CONTROLLED BY TIME DELAY SWITCH FURNISHED AND WIRED BY ELECTRICAL CONTRACTOR. 4. PROVIDE FAN SPEED CONTROLLER. NATIONAL ENGINEERING C ORP, Consulting Engineers n Cerk of Aut& / 6W 220 Live Oaks Boulevard, Casselberry, FL 32707 407 539-3400 Ames w. fowler, Jr., PS. / 4W71 03032©2W3 Nwml Engneaing Carp., All Mots Reswmdg_5-03 LO m V) w c� U 0 H w c� zw c>; o 0 C> 00 N a o o 0 Q � O Q � a � �j w n 00 r^ 'N C)`n lr n1 � J CD<� Q � �n V1 ®Q ,n 00 w 0�-�00r. v7w � � U� Z LJ Z::) E-+ o c:) " Z in CONTRACTOR SHALL VERIFY AL( CONDITIONS AND DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECT OF I ANY DIMENSIONAL ERRORS, OMISSIONS OR DISCREPANCIES BEFORE BEGINING OR FABRICATING ANY WORK. DO NOT SCALE DRAWINGS. i f Z Q � � LIJ zo J U� .-- Z O W 0 U o a Q O Cl- a--4 (n wLL_ [ o Q zcn Q � W fO ry LiJ Z V N O o. DRAWN BAV CHECKED j JMF DATE 09/02/03 SCALE AS NOTED I PROJECT NO. H32503 FIE NAME 3032-M 1 SHEET M I SHALL BE FOR 2 INCH SSIFICATION IN ITTH SMACNA. S SHALL NOT EXCEED TH AND BENDS MINIMUM CENTERLINE TIMES THE , 1-f HVA C PLAN SCAu: Vic - 1'-0" r7mm7mm� 0 4 8 10 (FEET) 20 GRAPHIC SCALE SUPPLY AIR DUCT WITH 2' EXTERNAL INSULATION ROUND STEEL DUCT W/MANUAL VOLUME DAMPER & 2 INSUL 1" WIDE, 22 GA, SEAL FLEX TO DUCT USING GALVANIZED STEEL GLASS FABRIC & MASTIC HANGER STRAP TO STRUCTURE 7'-'7 2" WIDE GALVANIZED STEEL FLEX DUCT SUPPORT STRAP UL 181, CLASS 1 FLEX DUCT STAINLESS STEEL BAND MAXIMUM LENGTH 5 FEET GALVANIZED STEEL OR PANDUIT STRAP / SECURE FLEX DUCT TO DUCT 2" BATT INSULATION WITH FOIL DIFFUSER NECK USING VAPOR BARRIER ON OUTSIDE ---- STAINLESS STEEL CLAMP OR PANDUIT STRAP SEAL INSULATION TO FLEX DUCT AND CEILING SELF -TAPPING SHEET DIFFUSER USING GLASS FABRIC & MASTIC DIFFUSER- SEE PLAN AND METAL SCREWS SCHEDULE FOR TYPE D UCT TO SUPPLY N T TO SCALE DUCT SUPPORT DETAIL M0015C NOT TO SCALE DIFFUSER CONN. DETAIL MD018J 0 5/8" THREADED HANGER ROD (MIN. OF 4 PER UNIT) CONNECT TO STRUCTURE VOLUME DAMPER WITH LOCKING QUADRANT BRANCH DUCT CONICAL TEE CONNECTION MEDIUM PRESSURE SUPPLY DUCT TRANSITION VAV BOX TRUNK DUCT 6" 45' ROUND DUCT � CHANNEL � SUPPLY AIR FLOW SUPPORT FLEXIBLE CONNECTION LOW PRESSURE RECTANGULAR SUPPLY RETURN AIR FLOW DUCT. GALVANIZED STEEL WITH 2" EXTERNAL INSULATION. BRANCH D UCT VAV BOX NOT TO SCALE CONN. DETAIL MD014A NOT TO SCALE INSTALLATION DETAIL MD034C SUPPORT PER SPECIFICATONS (TYP) BACKDRAFT DAMPER SAME DIMENSION POWER VENTILATOR AS NECK SIZE EXHAUST DUCT DUCT MATERIAL SIMILAR TO SUPPLY AIR DUCT CEILING SEE SPECIFICATIONS 6" MINIMUM CAVITY 7 CONNECT TO EXIST. PAINT INSIDE OF DUCT EXHAUST CEILING DUCT BY LANDLORD FLAT BLACK ON ALL 24" MINIMUM GRILLE VISIBLE SURFACES RETURN AIR GRILLE OR REGISTER AS SCHEDULED ON DRAWINGS NOT TO SCALE RETURN AIR BOOT DETAIL MD036K NOT TO SCALE POWER VENTILATOR DETAIL MD016G NATIONAL E NGINEEMO C ORP, Consulting Engineers A Cerk or aoch. / eszs 220 Live Oaks Boulevard, Casselberry, FL 32707 407 539-3400 Lames M. Fowler, Ir., AN./ 4w// 03032 ©2003 Natiaal Engnoering C«p., al W*ts Reserved g-5-03 � m I N w cD U 0 w w cy V) Ld Z, 0:� o'I w :z 0 r� 0 00 ¢' a �I r O m 7�) I:� V- H�--I E4 0 � o a I^ � � r �J CO M�Q Z JLno (D � ►-1 � r I r- ,n ao 0 LL U� Z V) Cq" z Q o �. N U) � H CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECT OF ANY DIMENSIONAL ERRORS, OMISSIONS OR DISCREPANCIES BEFORE BEGINING OR FABRICATING ANY WORK. DO NOT SCALE DRAWINGS. III lO i1 . �v• O cl- 4 J Lli V) O < < O w--- Z DRAWN BAV CHECKED JMF DATE 09/02/03 SCALE AS NOTED PROJECT NO. H32503 FILE NAME 3032-M2 SHEET M-2 DIVISION 16000 - ELECTRICAL SPECIFICATIONS 16100 - ELECTRICAL 1.1 GENERAL A. PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, FEES, AND ELECTRICAL PERMITS AND ALL NECESSARY ITEMS TO INSTALL A COMPLETE ELECTRICAL SYSTEM- B. PROVIDE COMPLETE SYSTEMS, REGARDLESS OF WHETHER EACH INDIVIDUAL COMPONENT IS MENTIONED OR NOT. C. THE WORK SHALL COMPLY WITH THE STANDARDS IN THE LATEST APPLICABLE EDITIONS OF THE FOLLOWING LISTED CODES AND ORDINANCES: I. NFPA NO, 70 "NATIONAL ELECTRIC CODE". 2- NECA "STANDARD OF INSTALLATION." 3. ELECTRIC UTILITY COMPANY SERVICE STANDARDS. 4. TELEPHONE UTILITY COMPANY SERVICE STANDARDS. 5. CABLE TV UTILITY COMPANY SERVICE STANDARDS. 6. UNDERWRITER'S LABORATORY STANDARDS. 7. OTHER LOCAL CODES, ORDINANCES AND LAWS APPLICABLE TO THE PLACE OF WORK. D. RELATED WORK SPECIFIED ELSEWHERE: 1. REFER TO THE ARCHITECTURAL, STRUCTURAL AND TO THE MECHANICAL DIVISIONS OF THE WORK FOR ELECTRICAL WORK TO BE DONE IN CONJUNCTION WITH THESE DIVISIONS. 2. VERIFY LOCATIONS AND ELECTRICAL REQUIREMENTS OF ALL EQUIPMENT FURNISHED BY THE OWNER OR OTHER TRADES PRIOR TO INSTALLATION OF CONDUIT AND WIRE. E. SUBSTITUTIONS: EQUIPMENT AND DESIGN OF SYSTEMS INDICATED ON THE DESIGN DRAWINGS AND WITHIN THE SPECIFICATIONS ARE CONSIDERED AS "SPECIFIED STANDARDS" OF QUALITY AND WITH DIMENSIONS OF THE SPECIFIED MATERIALS FORM THE BASIS OF DESIGN. F. PRODUCTS: ALL MATERIALS SHALL BE NEW AND OF THE BEST QUALITY, FREE OF DEFECTS. WHERE APPLICABLE, ALL MATERIALS SHALL BE U.L. LISTED OR BE LISTED WITH AN APPROVED TESTING AGENCY. G. WORKMANSHIP: ALL MATERIALS SHALL BE FABRICATED AND INSTALLED IN A NEAT AND WORKMANLIKE MANNER WITH THE COORDINATION OF ALL TRADES TO AVOID INTERFERENCE AND DELAY DUE TO LACK OF COORDINATION. H. SHOP DRAWINGS: SUBMIT FOR ARCHITECTS.OWNER/ENGINEER REVIEW SHOP DRAWINGS FOR LIGHTING FIXTURES, PANELBOARDS, WIRING DEVICES AND OTHER MAJOR COMPONENTS AS INDICATED ON THE CONSTRUCTION DOCUMENTS. I. CLEANING, TESTING AND ADJUSTING: CLEAN, REPAIR, ADJUST, CHECK, BALANCE AND PLACE IN SERVICE THE VARIOUS SYSTEMS SHOWN ON THE CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL PROVIDE ALL TOOLS, EQUIPMENT AND MATERIALS REQUIRED TO PERFORM THE REQUIREMENTS OF THE SPECIFICATIONS AND THE REQUIREMENTS OF THE GOVERNING AUTHORITY. NO WORK SHALL BE COVERED OR CONCEALED UNTIL PROPERLY TESTED. J. GUARANTEE AND WARRANTY: PROVIDE WRITTEN GUARANTEE TO THE OWNER STATING THAT ALL WORK HAS BEEN PERFORMED IN ACCORDANCE WITH THE CONSTRUCTION DOCUMENTS AND WARRANTY ALL WORK AGAINST DEFECTS DUE TO FAULTY WORKMANSHIP OR MATERIALS FOR A PERIOD OF ONE YEAR FROM BENEFICIAL OCCUPANCY. K. AS -BUILT DRAWINGS: KEEP TWO SETS OF WHITE PRINTS ON THE JOB SITE, AND NEATLY MARK UP DESIGN DRAWINGS TO REFLECT MODIFICATIONS AND ALTERNATIONS MADE TO THE BASE DESIGN AS A RESULT OF OWNER DIRECTED REVISIONS OR COORDINATION WITH THE OTHER TRADES. L. SERVICE INTERRUPTIONS AND UTILITY: COORDINATE WITH THE OWNER THE INTERRUPTION OF UTILITY SERVICES NECESSARY TO ACCOMPLISH THE WORK. M. IDENTIFICATION: PROPERLY LABEL ALL PANELBOARDS, DISTRIBUTION PANELBOARDS, SIGNAL DISTRIBUTION SYSTEMS INCLUDING FEEDER CIRCUITS. PROVIDE TWO COPIES OF TYPED PANELBOARD SCHEDULES. N. PERFORMANCE VERIFICATION: PRIOR TO THE FINAL INSPECTION TEST FEEDER AND BRANCH CIRCUIT CONDUCTORS #6 AWG AND LARGER FOR SHORTS, OPEN, INTENTIONAL AND UNINTENTIONAL GROUNDS BY MEANS OF AN APPROVED TYPE OF CONSTANT "MEGGER". PERFORM A TEST OF THE GROUND SYSTEM. THE RESISTANCE BETWEEN GROUND AND ABSOLUTE EARTH SHALL NOT EXCEED 25 OHMS. 0_ LAYOUT OF WORK: CORRELATE FINAL EQUIPMENT LOCATIONS WITH GOVERNING ARCHITECTURAL DRAWINGS. PROVIDE COORDINATION OF ALL TRADES REQUIRED FOR INSTALLATION IN A NEAT AND WORKMANLIKE MANNER. P. SITE INVESTIGATION: CHECK SITE AND EXISTING CONDITIONS THOROUGHLY BEFORE BIDDING. ADVICE ARCHITECT OF DISCREPANCIES. R. SUPERVISION OF WORK: PROVIDE A FIELD SUPERINTENDENT WHO HAS A MINIMUM OF FOUR YEARS EXPERIENCE ON PROJECTS OF A SIMILAR NATURE AND SIZE. THE SUPERINTENDENT SHALL BE PRESENT AT ALL TIMES THAT WORK UNDER THIS DIVISION IS BEING INSTALLED OR AFFECTED. S. COORD'HATION: PROVIDE ALL COORDINATION AND SUPERVISION WHERE WORK CONNECTS TO OR IS AFFECTED BY OTHER TRADES. LOCATE ALL OPENINGS REQUIRED FOR WORK PERFORMED UNDER THIS SECTION. T. BASIS OF WIRING DESIGN: THE CONSTRUCTION DOCUMENTS DESCRIBE SPECIFIC SIZES OF EQUIPMENT. THESE SIZES ARE BASED UPON SPECIFIC ITEMS OF EQUIPMENT. WHEREVER THE CONTRACTOR PROVIDES EQUIPMENT WHICH DIFFERS FROM THE DOCUMENTS, THE ASSOCIATED WIRING AND CIRCUIT COMPONENTS SHALL BE CHANGED TO THE PROPER SIZE FOR THE EQUIPMENT BEING INSTALLED WITH NO ADDITIONAL COST TO THE OWNER. U. SURFACE MOUNTED EQUIPMENT AND RACEWAYS SHALL BE PAINTED UNDER DMSION 9. COLOR AS SELECTED BY THE ARCHITECT. V. PROTECTION AND CLEAN UP: SUITABLY PROTECT ALL EQUIPMENT AND FINISHES DURING CONSTRUCTION. RESTORE ALL DAMAGED SURFACES TO "LIKE NEW CONDITION". W. PROGRESS OF WORK: KEEP A DAILY JOB LOG OF WORK ACCOMPLISHED, FIELD DIRECTIONS AND EQUIPMENT RECEIVED ON THE JOB SITE. X. PROVIDE OPERATION AND MAINTENANCE MANUALS: FOR ELECTRICAL EQUIPMENT UTILIZED ON THE PROJECT. 1.2 MATERIALS AND WORKMANSHIP A. ASSUME FULL RESPONSIBILITY FOR THE TIMELY PLACEMENT OF ALL CONDUITS, OUTLET BOXES, CABINETS, AND OTHER WIRING DEVICES IN THE WALLS, CEILINGS, ETC., AS THE CONSTRUCTION PROGRESSES. B_ RACEWAY AND CONDUIT SYSTEMS: 1. SIZE RACEWAY AS REQUIRED BY THE NATIONAL ELECTRICAL CODE WITH OVERSIZED CONDUITS AS INDICATED. PROVIDE COMPLETE RACEWAY SYSTEMS INCLUDING CONDUIT, SUPPORTS, BOXES AND ENCLOSURES AND ALL CONNECTIONS TO ELECTRICAL EQUIPMENT. CONCEAL RACEWAY IN FINISHED AREAS UNLESS INDICATED OTHERWISE. INSTALL EXPOSED RACEWAY PARALLEL OR PERPENDICULAR TO WALLS, CEILING OR STRUCTURAL MEMBERS. 2, CONDUIT SYSTEMS SHALL BE SUSPENDED FROM OR AFFIXED TO THE BUILDING SUPERSTRUCTURE ONLY. 3. ALL RACEWAYS SHALL BE RUN IN A NEAT AND WORKMANLIKE MANNER AND SHALL BE PROPERLY SUPPORTED IN ACCORDANCE WITH THE NEC WITH APPROVED CONDUIT STRAPS, CLAMPS, HANGER RODS AND STRUCTURAL FASTENERS. NON -BOLTED CONDUIT CLAMPS SUPPORTING OF THE CONDUIT SYSTEM FROM SUSPENDED CEILINGS IS NOT BE PERMITTED. 4. ALL RACEWAYS SHALL BE CAPPED DURING THE COURSE OF CONSTRUCTION. NO CONDUCTORS SHALL BE PULLED UNTIL THE RACEWAY SYSTEM IS COMPLETE. 5. RACEWAYS FOR BRANCH CIRCUITS AND FEEDERS SHALL HAVE AN INSULATED COPPER SYSTEM GROUND CONDUCTOR THROUGHOUT THE ENTIRE LENGTH OF THE CIRCUIT IN ACCORDANCE WITH THE NEC. GROUNDING CONDUCTORS SHALL BE INCLUDED IN THE TOTAL CONDUIT FILL WHEN DETERMINING CONDUIT SIZE. 6. AN APPROVED NYLON PULL -CORD SHALL BE INSTALLED IN ALL EMPTY CONDUITS. PULLCORDS SHALL BE FASTENED TO PREVENT ACCIDENTAL REMOVAL, 7. CIRCUIT NUMBERS AND SYSTEM IDENTIFICATION SHALL BE PRINTED ON JUNCTION BOX COVERS USING INK MARKERS AND BE PLAINLY VISIBLE. 8. CONDUIT SHALL BE EMT FOR BRANCH CIRCUIT WIRING WITH CAST FERROUS COMPRESSION. SET SCREW FITTINGS. METAL CLAD CABLE (MC) MAY BE USED WHERE ALLOWED BY CODE. MC CABLE SHALL NOT BE USED WHERE EXPOSED. MC CABLE SHALL BE USED IN WIRING CHANNELS IN BOTTOM OF WOOD MEMBERS. PVC (SCH 40) SHALL BE USED BELOW GRADE ONLY. PVC CONDUIT SHALL TRANSITION TO RIGID GALVANIZED STEEL BELOW GRADE, PRIOR TO STUB -UP. FLEXIBLE CONDUIT SHALL BE USED TO MAKE FINAL CONNECTION TO ELECTRICAL EQUIPMENT WHERE REQUIRED, 36" MAX. LIQUID TIGHT SHALL BE USED FOR EXTERIOR APPLICATIONS, 36" MAX. C. WIRE AND CABLE: 1. BRANCH CIRCUIT AND FEEDER CONDUCTORS SHALL BE COPPER 600 VOLT TYPE THHN, THWN OR THW. CONDUCTORS # 10 AWG AND SMALLER SHALL BE SOLID. THE MINIMUM WIRE SIZE SHALL BE #12 AWG UNLESS NOTED OTHERWISE. NO ALUMINUM WIRE SHALL BE PERMITTED. 2. ALL COPPER TAPS AND SPLICES NO. 8 AWG OR SMALLER SHALL BE FASTENED WITH WIRENUT CONNECTORS. ALL TAPS AND SPLICES LARGER THAN NO. 8 AWG SHALL BE MADE WITH COLOR KEYED HIGH COMPRESSION TYPE CONNECTORS, AN APPROVED SHRINK SLEEVE TO EQUAL INSULATION RATING OF THE WIRE SHALL BE USED TO INSULATE SPLICES. 3. ALL POWER FEEDERS AND BRANCH CIRCUITS #8 AWG AND SMALLER SHALL BE WIRED WITH COLOR -CODED WIRE AS HEREIN SPECIFIED. POWER FEEDERS #8 AWG AND LARGER SHALL EITHER BE COLOR -CODED WITH TAPE OR PAINT IN ALL JUNCTION BOXES AND PANELS. 120/208 VOLT. BLACK -RED -BLUE (PHASES A-B-C) NEUTRALS - WHITE GROUND - GREEN, BARE OR GREEN WITH YELLOW STRIPES SWITCH LEGS - OTHER THAN THOSE UTILIZED ABOVE. 277/480 VOLT - ORANGE, BROWN, YELLOW. PHASES A, B & C. D. OUTLET BOXES: 1. OUTLET BOXES SHALL BE AS REQUIRED FOR THE SPECIFIC USE AND LOCATION, TYPE OF DEVICE OR FIXTURES TO BE USED, AND NUMBER AND SIZE OF CONDUCTORS. MINIMUM SINGLE GANG. BOXES SHALL BE OF ONE PIECE CONSTRUCTION. WELDED BOXES WILL NOT BE APPROVED. 2. SURFACE BOXES CAST FERROUS WITH INTEGRAL HUBS 3. CEILING BOXES 4" SQUARE BY 1-1/2" DEEP OR LARGER AS REQUIRED FOR NUMBER AND SIZE OF CONDUCTORS. 4. FLUSH OUTLET BOXES, ONE PIECE STEEL OUTLET BOXES BY STEEL CITY OR RACO. BOXES SHALL BE MOUNTED SO THAT COVERS AND PLATES WILL FINISH FLUSH WITH FINISHED SURFACES WITHOUT THE USE OF SHIMS, MATS, OR OTHER DEVICES. PLATES SHALL NOT SUPPORT WIRING DEVICES. GANG SWITCHES WITH COMMON COVERPLATES WHERE TWO OR MORE ARE INDICATED IN THE SAME LOCATION. OUTLETS ON EACH SIDE OF THE WALL SHALL HAVE SEPARATE BOXES, THROUGH -WALL TYPE BOXES OR BACK-TO-BACK MOUNTING SHALL NOT BE PERMITTED. TRIM RINGS SHALL BE EXTENDED TO WITHIN 1/4" OF FINISH WALL SURFACE. 5. OUTLET BOXES MOUNTED IN STUD WALLS ARE TO BE SUPPORTED TO STUDS WITH TWO SCREWS INSIDE OF OUTLET BOX TO A HORIZONTAL STUD BRACE BETWEEN VERTICAL STUDS. 6. OUTLET BOXES THAT DO NOT RECEIVE WIRING DEVICES SHALL BE PROVIDED WITH BLANK PLATES TO MATCH INSTALLED WIRING DEVICE PLATES. 7. OUTLET BOXES/CONDUIT BODIES EXPOSED TO THE WEATHER, NOT CONTAINED INSIDE BUILDING WALLS, SHALL BE TYPE FS, FD, LB OR LL MALLEABLE IRON. COVERS SHALL BE OF THE TYPE AND OF THE SAME MANUFACTURER AS THE CONDUIT BODIES AND SHALL BE SUITABLE FOR THE USE IN THE AREA SERVED. CAST ALUMINUM BOXES WILL NOT BE APPROVED. 8. MOUNTING HEIGHTS OF DEVICES (UNLESS OTHERWISE NOTED) SWITCHES 48" TO CENTER RECEPTACLES 18" TO CENTER TELEPHONE/DATA OUTLET 18" TO CENTER LIGHTING PANELS 6'-6" TO TOP OF PANEL TRIM. ALL WIRING DEVICES SHALL BE S9ECIFICATION GRADE, ARROW HART OR EQUAL. 9. LOCATE SPECIAL PURPOSE OUTLETS AS INDICATED ON THE DRAWINGS FOR THE EQUIPMENT SERVED. LOCATION AND TYPE OF OUTLETS SHALL BE COORDINATED WITH THE APPROPRIATE TRADES INVOLVED. THE SECURING OF COMPLETE INFORMATION FOR PROPER ELECTRICAL ROUGH -IN SHALL BE INCLUDED AS WORK REQUIRED UNDER THIS DIVISION OF THE CONTRACT. F. CONVENIENCE RECEPTACLES SHALL BE 20 AMP, 125 VOLT NEMA 5-20R, UNLESS NOTED OTHERWISE. COVER PLATES SHALL MATCH ADJACENT SURFACE COVER PLATES IN KITCHEN SHALL BE STAINLESS STEEL. G. WALL SWITCHES SHALL BE 20 AMP, 120/277 V AC, SINGLE POLE, UNLESS NOTED OTHERWISE. COVER PLATES SHALL MATCH ADJACENT SURFACE. COVER PLATES IN KITCHEN SHALL BE STAINLESS STEEL. H. WIRING DEVICE PLATES SHALL BE PLASTIC, PAINTED TO MATCH WALL, IN DINING ROOMS, STAINLESS STEEL IN KITCHEN AND BAR AREAS AND IVORY PLASTIC IN OFFICE, LIQUOR STORAGE ROOM AND TOILETS. PROVIDE BLANK COVER PLATES FOR ALL UNUSED OUTLETS (DATA, TELEPHONE, ETC.). 1. PROVIDE PANELBOARDS AS SCHEDULED ON THE DRAWINGS. CUTLER HAMMER, SQUARE D, OR SIEMENS ALL TERMINALS SHALL 13E RATED FOR 75 DEGREES C MINIMUM. ALL PANELBOARDS SHALL HAVE SOLID COPPER BUSSES. SHORT CIRCUiT RATING SHALL BE AS LISTED ON PANEL SCHEDULES. J. GROUND THE ELECTRICAL SYSTEM IN ACCORDANCE WITH ARTICLE 250 OF THE NATIONAL ELECTRICAL CODE AND WITH LOCAL REQUIREMENTS. GROUND SERVICE TO BUILDING STEEL, DRIVEN GROUND ROD, AND COLD WATER PIPE. K. MAKE FINAL CONNECTIONS TO ALL ELECTRICAL EQUIPMENT SET IN PLACE BY OTHERS. MAKE ELECTRICAL CONNECTIONS TO ALL ITEMS SHOWN AS PART OF THE GENERAL CONTRACT WHICH REQUIRE ELECTRICITY. L.. FURNISH AND INSTALL EQUIPMENT DISCONNECTS AS INDICATED OR REQUIRED. FUSES IN ALL DISCONNECT SWITCHES AND OTHER FUSIBLE DEVICE SHALL BE DUAL ELEMENT CURRENT LIMITING TYPE. FURNISH WITH 3 SPARE FUSES OF EACH TYPE AND SIZE USED ON THE JOB. SWITCHES AND FUSES SHALL BE SIZE TO SUIT THE ACTUAL EQUIPMENT BEING SERVED. M. CONNECT MOTOR STARTERS, RELAYS, SWITCHES, AND RELATED ITEMS WHICH ARE PROVIDED UNDER THE MECHANICAL WORK. N. DUCTWORK TAKES PRECEDENCE OVER ELECTRICAL CONDUIT. COORDINATE CONDUIT RUNS TO ALLOW DUCTWORK TO BE INSTALLED AS DRAWN. LIGHT FIXTURES TAKE PRECEDENCE OVER DUCTWORK. 0. ALL INTERIOR LIGHTS SHALL BE CONTROLLED FROM WALL SWITCHES. LIGHTS SHALL NOT BE SWITCHED FROM PANELS P. ALL ENCLOSURES SHALL BE OF THE NEMA TYPE WHICH IS SUITABLE FOR THE APPLICATION. R, ALL WORK SHALL HAVE PROPER LABELING. ALL CIRCUITS SHALL BE LABELED AT PANELS AND BOXES AS INDICATED. ALL PANELS AND DISCONNECTS ARE TO BE PERMANENTLY MARKED WITH NAME OR EQUIPMENT SERVED UTILIZING ENGRAVED NAMEPLATES, LAMINATED PHENOLIC BLACK WITH WHITE LETTERS, 3/8" MIN. ALL PANELS ARE TO BE APPROVED WITH TYPE WRITTEN PANEL SCHEDULES. S. ALL CIRCUIT BREAKERS SERVING AIR CONDITIONING AND REFRIGERATION EQUIPMENT SHALL BE HACR RATED. T. PROVIDE AND INSTALL CONDUIT AND JUNCTION BOXES FOR INTERIOR LIGHTING AS INDICATED AND/OR REQUIRED. U. DISCONNECT SWITCHES SHALL BE RATED HEAVY DUTY, FULLY ENCLOSED WITH DUAL COVER LOCKS, QUICK-MAKE/QUICK-BREAK MECHANISMS AND DUAL HORSEPOWER RATED. PROVIDE NEMA-3R ENCLOSURES IN EXTERIOR OR DAMP LOCATIONS AND NEMA-4 ENCLOSURES IN WET LOCATIONS. PROVIDE FUSED AND NON -FUSED AS INDICATED ON THE DRAWINGS. PROVIDE FUSE CLIPS ON FUSIBLE SWITCHES OF 30A TO 600 AMPS TO PREVENT INSTALLATION OF NON -CURRENT LIMITING FUSES. V. LIGHTING FIXTURES SHALL BE FURNISHED COMPLETE WITH LAMPS AND ALL NECESSARY TRIM AND MOUNTING HARDWARE AND INSTALLED AS SHOWN ON THE DRAWINGS AND PER THE MANUFACTURER'S RECOMMENDED INSTALLATION GUIDES. FIXTURES SHALL BE FIRMLY MOUNTED USING STANDARD SUPPORTS FOR OUTLET AND FIXTURES. LAMPS SHALL HAVE A 30 DAY GUARANTEE AFTER FINAL ACCEPTANCE OF THE SPACE. W. EXTEND EXISTING BUILDING FIRE ALARM SYSTEM AS REQUIRED TO ACCOMODATE NEW RECREATIONAL WAREHOUSE FACILITY. PROVIDE EQUIPMENT TO MATCH EXISTING MALL INSTALLATION. END OF DIVISION 16000 ELECTRICAL SYMBOL LIST E�Rp FLOURESCENT FIXTURE, RECESSED TROFFER, 2'x4' & 2'x2' RECESSED FLUORESCENT FIXTURE WITH BATTERY PACK. WALL MOUNTED EXIT LIGHT WALL MOUNTED EMERGENCY LIGHT, BATTERY UNIT DUPLEX RECEPTACLE, NEMA 5-20R, 15"AFF. @-- DUPLEX RECEPTACLE, NEMA 5-20R, 457AFF OR AS NOTED 42� DUPLEX RECEPTACLE, NEMA 5-20R, GFI, 15"AFF. # DUPLEX RECEPTACLE, NEMA 5-20R, GFI, 45"AFF OR AS NOTED a SWITCH, SINGLE POLE, 20A 120/277 VOLT. 45" AFF - SUB LETTER DENOTES SWITCHING CIRCUIT 3 SWITCH, 3 WAY, 20A 120/277 VOLT. 45" AFF - SUB a LETTER DENOTES SWITCHING CIRCUIT JO JUNCTION BOX OR EQUIPMENT CONNECTION ® EXHAUST FAN OH COMBINATION HEAT DETECTOR DD4 FIRE ALARM HORN AND STROBE UNIT, 8'-0" AFF OS CEILING MOUNTED SMOKE DETECTOR WIRING, CONCEAAED ABOVE CEILING OR IN WALL, OR EXPOSED / ARROWHEADS INDICATE HOMERUN CIRCUITS. -� WIRING, IN SLAB OR BELOW GRADE, ARROWHEADS AS ABOVE. AFF ABOVE FINISH FLOOR NFSS NON FUSIBLE SAFETY SWITCH © 6"x6"x4" SCREW COVER JUNCTION BOX, 18" AFF. LEAVE 24" OF CONDUCTORS FOR USE OF TENANT. INSULATE ENDS OF CONDUCTORS, COIL UP IN BOX. © SURFACE METAL RACEWAY WITH 20A DUPLEX RECEPTACLES ON 4 FT. CENTERS. WIREMOLD 3000 SERIES OR EQUAL. MOUNT ON WALL 8'-6" AFF. FLOOR LINE TO REMAIN AS IS TO REMAIN AS IS C1 C2 I C3 C4 C5 C6 C7 C8 C9 EXISTING 3" CONDUIT TO RECREATIONAL WAREHOUSE SPACE--"e� O PROVIDE NEW 200A SWITCH IN EXISTING SPACE C3. FUSE AT 125A. DETAIL - MAIN SWITCHBOARD - ELECTRIC ROOM 2A NOT TO SCALE N OA 08 0C GND PRIMARY FEEDER MER SAD IV FEEDER TO PANEL 0A N 06 0C TYPICAL TRANSFORMER WIRING DIAGRAM NOT TO SCALE FI FCTRIC ROOM 2A ON NATIONAL ENGINEERING CORP. Consulting Engineers n cert. of AuA / UM 220 Live Oaks Boulevard, Casselberry, FL 32707 407 539-3400 fanws M. Foirim Zr., PS. / 4M71 03032 ©2W3 National Engineering Cap., All flights Rv ved9-5-03 C T� i V) W (.9 ,U 0 V) w 1:::) Cy V) w °[ o oC w 0 0 cV a o o r- 0 Z N V I 0 c Q V N E- _o v Q CD v U C a r- a w 00 Z o ' ^ a M - M I ,/ � J V o `� o Q I > V 1 ►--� J Ln o ER I r- 1 to 00 LLJ�1 �' 4 00 n CD LLI :D o z F-. V a W rr� N a `'a � V1 ::E 1.4 0 �o v s o U v - 0 o v � a p N s CONTRACTOR SHALL VERIFY ALLI CONDITIONS AND DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECT q OF ANY DIMENSIONAL ERRORS, OMISSIONS OR DISCREPANCIES BEFORE BEGINING OR FABRICATING ANY WORK. DO NOT SCALE DRAWINGS. V i 0 0 Ca- .2 o � U L O a .o a J U Ld Wp u Lil 0 v) QLL_ o '`+ LJ O ®� CL 0 46 LLJ � �..q J Li L� C o < z () a L,J o � a v � L ij # F- Z o - v L I- 0 0 N I a 2 o Q, U I DRAWN BAV CHECKED JDW DATE 09/02/03 SCALE AS NOTED PROJECT NO. H32503 FILE NAME j 3032-El SHEET E VOLTAGE: 208Y1 120 3 PHASE 4 WIRE Y PANEL (EXISTING) PANEL TYPE: NQOD MAINS: 150A. MAIN CIRCUIT BREAKER RAL BUS AMPACITY 100% SQUARE D OR EQUAL MOUNTING: FLUSH AIC RATING 10K GROUND BUS AMPACITY 50% CIRCUIT IDENTIFICATION PHASE A KVA PHASE B KVA PHASE C KVA DEMAND FACTOR DEMAND KVA TRIP AMPS POLES CIRCUIT # CIRCUIT # POLES TRIP AMPS PHASE A KVA PHASE B KVA PHASE C KVA DEMAND FACTOR KVA DEMAND CIRCUIT IDENTIFICATION SALES AREAS LIGHTING 0.90 0.00 0.00 1.25 1.13 20 1 1 2 1 20 1.50 0.00 0.00 1.00 1.50 SALES ROOM RECEPTS. SALES AREAS LIGHTING 0.00 0.90 0.00 1.25 1.13 20 1 3 4 1 20 0.00 1.50 0.00 1.00 1.50 SALES ROOM RECEPTS. SALES AREAS LIGHTING 0.00 0.00 0.90 1.25 1.13 20 1 5 6 1 20 0.00 0.00 1.50 1.00 1.50 SALES ROOM RECEPTS. SALES AREAS LIGHTING 0.90 0.00 0.00 1.25 1.13 20 1 7 8 1 20 1.50 0.00 0.00 1.00 1.50 SALES ROOM RECEPTS. SALES AREAS LIGHTING 0.00 0.90 0.00 1.25 1.13 20 1 9 10 1 20 0.00 1.50 0.00 1.00 1.50 SALES ROOM RECEPTS. SALES AREAS LIGHTING 0.00 0.00 0.90 1.25 1.13 20 1 11 12 1 20 0.00 0.00 1.50 1.00 1.60 STOCK RM RECEPTS. STOCK ROOM LIGHTING 0.72 0.00 0.00 1.25 0.90 20 1 13 14 1 20 1 1.50 0.00 0.00 1.00 1.50 TOILET GFI RECEPTT, SIGN OUTLET 0.00 0. 1. 1.00 20 1 15 16 1 20 0.00 0,50 0.00 1.00 0.50 TELEPHONE RECEPT. WIREMOULD STRIP 0.00 0.00 1.00 1.25 1.25 20 1 17 18 1VG-GQV --R,M 0.00 VAV UNITS WIREMOULD STRIP 1.00 0.00 0.00 1.25 1.25 20 19 20 2 30 2.25 0.00 0.00 1.00 2.25 WATER HEATER WIREMOULD STRIP 0.00 1.00 0.00 1.25 1.25 20 1 21 22 1 0.00 2.25 0.00 1.00 2.25 CASH REGISTER 0.00 0.00 0.3 1.00 0.3 1 23 24 0 NL SFACEIONLY 0. 1 25 26 1 0,00 0.00ro, 00 0.00 0.00 SPACE ONLY SPACE ONLY 0.00 0.00 0.00 0.00 0.00 1 27 28 1 0.00 0,00 0.00 0.00 0.00 SPACE ONLY SPACE ONLY 0.00 0.00 0.00 0.00 0.00 1 29 30 1 0.00 0.00 0,00 0.00 0.00 SPACE ONLY SPACE ONLY 0.00 0.00 0.00 0.00 0.00 1 31 32 1 0.00 0.00 0.00 0.00 0.00 SPACE ONLY SPACE ONLY 0.00 0.00 0.00 0.00 0.00 1 33 34 1 0.00 0.00 0.00 0.00 0.00 SPACE ONLY SPACE ONLY 0.00 0.00 0.00 0.00 0.00 1 35 36 1 0.00 0.00 0.00 0.00 0.00 SPACE ONLY SPACE ONLY 0,00 0.00 0.00 0.00 0.00 1 37 38 1 0.00 0.00 0.00 0.00 0.00 SPACE ONLY SPACE ONLY 0.00 0.00 0.00 0.00 0.00 1 39 40 1 0.00 0.00 0.00 0.00 0.00 SPACE ONLY SPAC 0.00 0.00 0.00 2 0.00 0.00 0.00 0 SPACE ONLY TOTAL PHASE KVA 3.52 1 3.80 1 3.10 1 6.75 5.76 3.00 TOTAL CONN. AMPERES 85.58 DEMAND AMPS. 65.83 MAX. PHASE AMPERES 85.58 TOTAL CONN. AMPERES 79.58 TOTAL CONNECTED KVA 25.92 TOTAL CONN. AMPERES 60.83 DEMAND kVA 23.70 bl, ��♦ice � �.�`r��► � �►�i� �� �► ...� �... �� .�. ��r► NEUTRAL BUS AMPACITY 100% GROUND BUS AMPACITY 50% RCUIT # CIRCUIT # POLES TRIP AMPS PHASE A KVA PHASE B KVA PHASE C KVA DEMAND FACTOR KVA DEMAND CIRCUIT IDENTIFICATION 1 2 2 50 4,20 0.00 0.00 1.00 4.20 SPA J.13 3 4 30 0.00 4.20 0.00 1.00 4.20 5 6 2 50 0.00 0.00 4.20 1.00 4.20 SPA JB 7 8 4.20 0.00 0.00 1,00 4.20 9 10 1 20 0.00 0.00 0.00 0.00 0.00 SPARE 11 12 1 20 0.00 0.00 1.92 1.00 1.92 SPA RECEPTACLE 13 14 3 30 0.00 1.92 0,00 1.00 1.92 SPA F.EaPTACLE 15 16 0,00 0.00 0.00 0,00 0.00 SPACE ONLY 17 18 0.00 0.00 0,00 0.00 0.00 SPACE ONLY 19 20 3 30 0.00 0.00 0.00 0.00 0.00 SPACE ONLY 8.40 6.12 6.12 104.00 MAX. PHASE AMPERES 121. TOTAL CONNECTED KVA 39.3 TOTAL DEMAND KVA 37.44 RECREATIONAL FACTORY WAREHOUSE CODE COMPLIANCE LOAD ANALYSIS AREA KISF WATTS ISF POWER FACT. CONN. KVA DEM. FAC. MAXIMUM DEMAND DIV. FAC. DEM. KVA INTERIOR LTG. RETAIL AREA 4.4 3 0.9 14.67 1.25 18.33 1 18.33 SHOW WINDOW 96 LF @ 2 rANW.A 1EE 1 19.00 1.25 2175 1 23.75 MISC AREAS 0,591 2 0.9 1.31 1.25 1.64 1 2 192-G2 SPAS 4 SPAS WITH 50A 208 V.CIRCUITS @ 80% DEMAND 50A. X .8 = 40A X .208KV = 8.32 KVA X 4 = 1 33.28 1 33.28 1 33.28 3 SPAS WITH 20A.120 V. CIRCUITS @ 80% DEMAND 1 0.00 1 0.00 20 A. X .8 m 16A X .12KV -1.92 KVA X 3 5.76 1 5.76 1 5.76 LARGEST MOTOR . 5 HP = 6.44 KVA 25% 5 HP MOTOR FULL LOAD KVA = 1.72 1 1.72 1 1.72 60 FT. OF OUTLET STRIP 0180 VA PER L.F. 10.80 1 10.80 1 10.80 VAV BOXES LS 0.63 1 0.63 1 0.63 WATER HEATER 4.50 1 4.50 1 4.50 MISC LOADS 2.6 1 0.85 3.06 1 3.06 11 3.06 TOTALS 103.47 SYSTEM KV. 0.208 PHASES 3 MAXIMUM DEMAND AMPERES (M 208 VOLTS 287.21 EXISTING 480 - 208Y1120- V TRANSFORMER KVA 75.00 REQUIRED ADDITIONAL TRANSFORMER KVA 33.07 DESIGN ADDITIONAL TRANSFORMER KVA 45.0 TOTAL 4801277 - 2081120 VOLT TRANSFORMER KVA = 120.0 REQUIRED 4801277 VOLT FEEDER AMPACITY -a 144.6 A. REQUIRED 2081120 VOLT FEEDER AMPACITY FOR 75 KVA. TRANS. ■ - 208A. REQUIRED 2081120 VOLT FEEDER AMPACITY FOR 75 KVA. TRANI& w ■ 125A. SHORT CIRCUIT ANALYSIS SUMMARY PROJECT:RECREATIONAL WHS. SEMINOLE TOWN CTR. DATE: 08/29103 SYSTEM MVA: 500.00 BASE ( TRANSFORMER) KVA: 1000 TRANS. P.U.Z 5.75 CALCULATED lac AT TRANSFORMER TERMINALS 4045.63 FAULT FAULT LOCATION P.0 Z TO FAULT NOTES A lac AT FAULT 1 75 KVA TRANS. PRIMARY 0.5071412 WORST CASE 2371.75 2 PANEL B BUS 0.0514577 WORST CASE 4045.63 3 0.90 0.0000000 0.00 4 0.00 0.0000000 0.00 5 0.00 0.0000000 0.00 6 0.00 0.0000000 0.00 7 0.00 0.0000000 0.00 8 0.00 0.0000000 0.00 9 0.00 0.0000000 0.00 10 0.00 0.0000000 0.00 ELECTRICAL SCALE: 3/16" = 1'-0" 0 4 8 10 (FEET) 20 GWHIC SCALE REFERENCED NOTES: 1. APPROXIMATE LOCATION - EXISTING TRANSFORMER FEEDER FROM SWITCHBOARD IN ELECTRIC ROOM 2A. SEE SINGLE LINE POWER DIAGRAM FOR DETAILS. 2. APPROXIMATE LOCATION OF EXISTING TELEPHONE CABLE. EXTEND TO NEW TERMINAL BOARD ABOVE DROPPED CEILING. 3. EXISTING 48OA-208Y/120 VOLT, 75 KVA DRY TYPE TRANSFORMER. PROVIDE TRAPEZE HANGER AND SUSPEND FROM STRUCTURE ABOVE. LOCATE TRANSFORMER WITH V CLEARANCE FROM TOP OF TRANSFORMER TO DROPPED CEILING ABOVE_ 4, NEW PANEL W. MOUNT SO TOP OF PANEL IS 6'-6" AFF. 5. NEW TELEPHONE TERMINAL BOARD., 3/4" 4'x4' PLYWOOD, PAINT WITH 2 COATS OF BLACK ENAMEL_ LOCATE TOP OF BOARD 6'-6" AFF. 7. TRANSFORMER PRIMARY OVER CURRENT PROTECTION t EQUIPMENT. SEE DETAIL THIS SHEET. 8. PANEL B. 9. 45 KVA 480A-208Y/120V TRANSFORMER. MOUNT SAME AS 75 KVA TRANSFORMER (REFERENCE NOTE #3). 10. DEDICATED CIRCUIT FOR CASH REGISTER. COORDINATE WITH OWNER FOR EXACT LOCATION AND FI FVATION 220 Live Oaks Boulevard, Casselberry, FL 32707 407ZG39-3400 James b Fowler, It., PA / 4se71 03032 ©2003 NoWW Engineering Corp.• All {rights Reserved 9-5-03 I w z z 0 w V) w O v) O UJ 0!� � z O M O W 00 N \ Q CD a NLLL) o O O w n co Lo M O Z oQ l ~ J `- Q - O (� Ln CO O E -J 00 V1 F-1 N C n E� O z o CD UWN Z � H I 0 CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECT OF ANY DIMENSIONAL ERRORS, OMISSIONS OR DISCREPANCIES BEFORE BEGINING OR FABRICATING ANY WORK. DO NOT SCALE DRAWINGS. L � Q Z W Z OJ _ CDLd �® a Z LEI U U O o � ck- Q Q ® W 0 J U Q Q V) O Z Iw 0 a. DRAWN BAV CHECKED JDW DATE F- 09/02/03 SCALE AS NOTED PROJECT NO. H32503 FILE NAME 3032-E2 SHEET 0 196 Towne Center Ci Permit NO: 03-29591