HomeMy WebLinkAbout196 Towne Center Cir 03-2959 Plans review sheet Fire department (2)l 9G %OWNE C�2 G,2 p3 -a9s9 r-- 4— A SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, FI.32771 / P. O. Box 1788, Sanford, FI. 32772 (407 302-2520 / FAX (407) 330-5677 Pager (407) 918-0395 Plans Review Sheet Date: September 23, 2003 Business Address: 196 Towne Center Circle Occ. Ch. #34 New Mercantile Business Name: Recreational Factory Ware House Ph. ( ) Contractor: Unknown Ph. ( ) Fax. () Architect/Engineer: J.R.JJ & Associates Ph. (407) 875-0115 Fax (407) 875-0308 Reviewed [] Rejected [ Reviewed by: Timothy Robles, Fire Protection Inspector/Plans Examiner le -- Comment: Plans reviewed as Mercantile Occupancy. Class "B" per L.S.C. FD reserves right to require applicable code requirements if occupancy use changes. Fire Sprinkler plans to be submitted for review, permitting, and inspections. Fire Sprinkler system shall have design criteria to match mercantile storage/product. Sealed letter from Engineer of Record stating design criteria for sprinkler system needs to be submitted with construction plans. Fire sprinkler system shall be tied into Main Mall fire alarm panel. 1.1 Application — Existing Mall Space Mixed — N/A 1.2 Special Definitions - "Class B Mercantile " more than 4118 Sq ft, 011.3 Classification of Occupancy — New Mercantile 1.4 Classification of Hazard of Contents — 1.5 Minimum Construction — N/R 1 sR SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, FI. 32771 / P. O. Box 1788, Sanford, Fl. 32772 (407 302-2520 / FAX (407) 330-5677 Pager (407) 918-0395 2.2 Means of Egress Components - Shall be in accordance with Chapter #7 of Florida Fire Prevention Code Two (2) separate exits 2.3 Capacity of Egress —Per L.S.C.-2001 2.4 Number of Exits — O.K. Two (2) separate exits 2.5 Arrangement of Egress — O.K., will field verify 2.6 Travel Distance — O.K., Per 36.2.6 2.7 Discharge from Exits — O.K., will field verify, Ok, PER 36.2.6 2.8 Illumination of Means of Egress — O.K.; will field verify 2.9 Emergency Lighting — Fire Department will require test under battery back up 2.10 Marking of Means of Egress — O.K.; will field verify 2.11 Special Features — O.K. 3.1 Protection of Vertical Openings — N/N 3.2 Protection from Hazards — N/N 3.3 Interior Finish — Class "A" "B" 3.4 Detection, Alarm and Communications Systems - as per NFPA 72, Provide monitoring of fire sprinkler system, ( tie into malls main fire alarm panel ) 3.5 Extinguishing Requirements - as per NFPA 10, provide three (3) 4A60BC 3.6 Corridors — N/A - 4 Special Provisions - 5 Building Services 5.1 Utilities — as per provisions of section 9.1 5.2 HVAC — provide duct detectors for all A/C UNITS OVER 2000 C.F.M. 5.3 Elevators, Escalators, Conveyors (4A-47) — N/A 5.4 Rubbish Chutes, Incinerators, and Laundry Chutes — N/A Sanford City Code — Chapter 9 Fire Sprinklers: Required; also see 3.5 above L SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772 (407 302-2520 / FAX (407) 330-5677 Pager (407) 918-0395 Monitoring: Required by a U.L. listed Central Station for all mandated fire sprinklered properties Other: NFPA 1 3-5.1 Fire Lanes — Not Required 3-6.1 Key Box — Not Required; 3-7.1 Bldg. Address Number Posted and Legible _ Required SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772 (407 302-2520 / FAX (407) 330-5677 Pager (407) 918-0395 Plans Review Sheet Date: September 23, 2003 Business Address: 190 Towne Center Circle Occ. Ch. #34 New Mercantile Business Name: Recreational Factory Ware House Ph. Contractor: Unknown Ph. ( ) Fax. () Archi.tect/Engineer: JR.JJ & Associates Ph. (407) 875-0115 Fax (407) 875-0308 3 w Reviewed [ ] RevleWeC� Wltl COlriiriept [ ] Rejected [ ] Reviewed by: Timothy Robles, Fire Protection Inspector/Plans Examiner �. Comment: Plans reviewed as Mercantile Occupancy. Class `B" per L.S.C. FD reserves right to require applicable code requirements if occupancy use changes. Fire Sprinkler plans to be submitted for review, permitting, and inspections. Fire Sprinkler system shall have design criteria to match mercantile storage/product. Sealed letter from Engineer of Record stating design criteria for sprinkler system needs to be submitted with construction plans. Fire sprinkler system shall be tied into Main Mall fire alarm panel. 1.1 Application — Existing Mall Space Mixed — N/A 1.2 Special Definitions — "Class B Mercantile " more than 4118 Sq ft, 1.3 Classification of Occupancy — New Mercantile 1.4 Classification of Hazard of Contents — 1.5 Minimum Construction — N/R 1 SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION r 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772 (407 302-2520 / FAX (407) 330-5677 Pager (407) 918-0395 2.2 Means of Egress Components - Shall be in accordance with Chapter #7 of Florida Fire Prevention Code Two (2) separate exits 2.3 Capacity of Egress — Per L. S.C. -2001 2.4 Number of Exits — O.K. Two (2) separate exits 2.5 Arrangement of Egress — O.K., will field verify 2.6 Travel Distance — O.K., Per 36.2.6 2.7 Discharge from Exits — O.K., will field verify, Ok, PER 36.2.6 2.8 Illumination of Means of Egress — O.K.; will field verify 2.9 Emergency Lighting — Fire Department will require test under battery back up 2.10 Marking of Means of Egress — O.K.; will field verify 2.11 Special Features — O.K. 3.1 Protection of Vertical Openings — N/N 3.2 Protection from Hazards — N/N 3.3 Interior Finish — Class "A" "B" 3.4 Detection, Alarm and Communications Systems - as per NFPA 72, Provide monitoring of fire sprinkler system, ( tie into malls main fire alarm panel ) 3.5 Extinguishing Requirements - as per NFPA 10, provide three (3) 4A60BC 3.6 Corridors — N/A - 4 Special Provisions - 5 Building Services 5.1 Utilities — as per provisions of section 9.1 5.2 HVAC — provide duct detectors for all A/C UNITS OVER 2000 C.F.M. 5.3 Elevators, Escalators, Conveyors (4A-47) — N/A 5.4 Rubbish Chutes, Incinerators, and Laundry Chutes — N/A Sanford City Code — Chapter 9 Fire Sprinklers: Required; also see 3.5 above 2 SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32172 (407 302-2520 / FAX (407) 330-5677 Pager (407) 918-0395 Monitoring: Required by a U.L. listed Central Station for all mandated fire sprinklered properties Other: NFPA 1 3-5.1 Fire Lanes — Not Required 3-6.1 Key Box — Not Required; 3-7.1 Bldg. Address Number Posted and Legible _ Required 3