HomeMy WebLinkAbout2501 McCracken Rd 04-173 Fire alarm panelCITY OF SANFORD PERMIT APPLICATION Permit # : ` Date: Job Address: 2 501 MCC XACa 3D. SA-IRZ,P- 3 Description of WorkrNSi 1Ll, 14 Fl/l /4.rM1it,AN(. Ty wwNtfOtC.. TIDE E 5MAJO Historic District: Zoning: Value of Work: $ a335 , SC-1 Permit Type: Building Electrical Mechanical Plumbing Fire Sprinkle la Pool Electrical: New Service - # of AMPS Addition/Alteration Change of Service Temporary Pole Mechanical: Residential Non -Residential - Replacement New (Duct Layout & Energy Calc. Required) Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lines Plumbing/ New Residential: # of Water Closets 4 Plumbing Repair - Residential or Commercial Occupancy Type: Residential Commercial Industrial Total Square Footage: Construction Type: # of Stories: .t # of Dwelling Units: Flood Zone: (FEMA form required for other than X) Parcel #: ( Attach Proof of Ownership & Legal Description) Owners Name & Address: I AV t O Russlw - &3o 0IZl N(a . TNG . 2501. VVNCC, ILAGk.E,J I-Q , SAwlfdit(. 1 1 . 3211 ( _ _ Phone: `b"7-3O2- `404 1 Bonding Address: Mortgage Address: Architect/ Engineer: Phone: S' 7 Address: i --:. vvi U 0 LUUJ Fax: Application is hereby made.to obtain a permit to cIo tfiewdrk a 1 i di On ertifythatfto- work or installation has commenced prior to the issuance of a permit and that all work will be perfpmied to me s da- s all gug constikti(iii:in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK P Uiv1BI S, URNACE$t:BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. _ OWNER' S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work Will 5 done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. y, r•>,c--_ in//off Signature of Owner/Agent Date Sig t f Contractor/Agent 5ate Print Owner/Agent's Name Print Con r for/Agent' a pqSignature of Notary -State of Florida Date Signature of Notary -State of Florida Date Owner/ Agent is _ Produced I Personally Known to Me or APPLICATION APPROVED BY: Bldg. r to ^)-o-03 Zoning: Initial & Date) Special Conditions: ww r-nen L. Harris Contractor/ Agent is _ Personally Known to a or '.ommissim I)D217997 Produced Ii, .' ApuesAugust 1t1, 2007 Utilities: FD:'r _ .. 1016 Initial & Date) (Initial & Date) (Ini ial & Date) AC#0483797 STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION ELECTRICAL CONTRACTORS LICENSING BOARD SEQ#L02107i400O46 CHNSR NBR 97291 QRS The.ALARM SYSTEM CONTRACTOR liamedl,bdlow IS CERTIFIED Under the provisions of Chapt`` Expiration date: AUG 31, 2 0 0 4":'i g k. RINDGE,GUY W FRif SIMPLEXGRINNELL LP 801-G S ORLANDO AVENUE WINTER PARK FL 32789 JEB BUSH .' KIM BINKttY`9E'YERGOVERNORDISPLAYASREQUIREDPYLAWSECRETARY. F X-1 R ORANGE COUNTY OCCUPATIONAL LICENSE ORG I !AL '1-9, 3 0 2 0 0 3 ORANGE COUNTY, FLORWA 9. 3121 CERT ALARM/FIRE CONTR 225.00 100 WORKERS TOTAL TAX 225.00 S14KOLEXiGNINNELL LP TOTAL DUE 225.00 -11001N 'JOHN YOUNG PKWY STE AiLNDO'.FL,32804 3701 N JOHN YOUNG PY #110 A - ORLANDO RINDGE GUY W-QUALIFIER THIS FORM BECOMES A RECEWT 'V.jj4EN VA11WITED Blf THE TAX ;,01L.J.-ECTOR. r-'-- '----- '-' - - - ' - ------'-------------'--- MARSH CERTIFICATE NUMBER PRODUCER THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERSMarshUSAInc. NO RIGHTS UPON THE CERTIFICATE HOLDER OTHER THAN THOSE PROVIDED IN THE1166AvenueoftheAmericasPOLICY. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGENewYork, NY 10036-2774 AFFORDED BY THE POLICIES DESCRIBED HEREIN. Jessica Angiullo 212-345-3419 fax 212-345-5626 COMPANIES AFFORDING COVERAGE COMPANY INSURED COMPANY SIMPLEXGRINNELL LP B INSURANCE CO STATE OF PA SimplexGrinnell COMPANY Orlando, Fl. 32804 COMPANY THIS IS TO CERTIFY THAT POLICIES OF INSURANCE DESCRIBED HEREIN HAVE BEEN ISSUED TO THE INSURED NAMED HEREIN FOR , THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANYCONTRACTOR OTHER DOCUMENTWITH RESPECTTOWHICH THE CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, CONDITIONS AND EXCLUSIONS OF SUCH POLICIES. AGGREGATELIMITSSHOWNMAYHAVEBEENREDUCEDBYPAIDCLAIMS. co TYPE OF INSURANCE POLICY NUMBER POLICYEFFECTIVE POLICY EXPIRATION GENERAL LIABILITY GENERAL AGGREGATE 10,000,000 CLAIMS MADE - OCCUR PERSONAL & ADV INJURY 5,000,000II EACH OCCURRENCE 5,000.000OWNER'S & CONTRACTOR'S PROT FIRE DAMAGE (Anyone fire) 1,000,000 AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT 5,000,000 X HIRED AUTOS BODILY INJURY X NON -OWNED AUTOS Per accident) GARAGE LIABILITY AUTO ONLY - EA ACCIDENT OTHER THAN AUTO ONLY: ANY AUTO EACH ACCIDENT AGGREGATE EXCESS LIABILITY EACH OCCURRENCE AGGREGATEHUMBRELLAFORM OTHER THAN UMBRELLA FORM WORKERS COMPENSATION AND WC STATU- H. B THE PROPRIETOR/ INCL SEE PAGE TWO 10/01/02 10/01/03 EL DISEASE -POLICY LIMIT 1,000,000 EL DISEASE -EACH EMPLOYEE 1,000,000OFFICERSARE: EXCL OTHER DESCRIPTION OF OPERATIONSILOCATIONS/VEHICLESISPECIAL ITEMS The Certificate Holder is included as Additional Insured with respect to General Liability but only to the extent of the Named Insured's negligence in performing the contract. Sanford Building Dept. SHOULD ANY OF THE POLICIES DESCRIBED HEREIN BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF. 300 N. Park Ave. THE INSURER AFFORDING COVERAGE WILL ENDEAVOR TO MAIL __M DAYS WRITTEN NOTICE TO THE Sanford, Fl. 32771 CERTIFICATE HOLDER NAMED HEREIN. BUT FAILURE TO MAIL SUCH NOTICE SHALL IMPOSE NO OBLIGATION OR LIABII.ITY OF ANY KIND UPON THE INSURER AFFORDING COVERAGE. ITS AGENTS OR REPRESENTATIVES, OR THE ISSUER OF THIS CERTIFICATE. MARSH USA INC. BY: Katherine S. O'Leary Al",4— ON r PRODUCER Marsh USA Inc. 1166 Avenue of the Americas New York, NY 10036-2774 Jessica Angiullo 212-345-3419 fax 212-345-5626 58880 -TYCO-SIMPL-02/03 INSURED SIMPLEXGRINNELL LP WORKERS COMPENSATION POLICIES 10/01/02- 10-/01/03 STATE A) AMERICAN HOME ASSURANCE CA RMWC 3322419 A) AMERICAN HOME ASSURANCE NV,OR RMWC 3322420 B) INS CO.OF PENNSYLVANIA AR,FL,MA,TN,VA RMWC 3322421 C) ILLINOIS NATIONAL INS.CO. IL,LA RMWC 3322422 C) ILLINOIS NATIONAL INS. CO. NY,WI RM W C3322423 D) At SOUTH INSURANCE CO. GA RM W C3322424 A) AMERICAN HOME ASSURANCE CO. ALL OTHER STATES RMW C3322425 Sanford Building Dept. 300 N. Park Ave. Sanford, F1. 32771 COMPANY E COMPANY F COMPANY G COMPANY H x DATE (MMIDD/YY) hs NYC 001537564 01 09/23/02 COMPANIES AFFORDING COVERAGE r SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772 407 302-2520 / FAX (407) 330-5677 Pager (407) 918-0395 Plans Review Sheet Date: October 15, 2003 Business Address: 2501 Mc Cracken RD. Occ. Ch. 28Industrial Business Name: Russell Aluminum Ph. ( ) Contractor: Simplex Grinnell Ph. (407) 235-1100 Fax.(407) 235-1150 Reviewed [ ] Reviewe dwath Comment f Rejected Reviewed by: Timothy Robles, Fire Protection Inspecto Comment: Fire Department will require (2) two "31 JX" phone lines for fire alarm monitoring. 1.1 Application — Sanford Fire Prevention will require "Knox Box " on building for after hour key access 1.2 Monitoring- Sanford Fire Prevention will field verify (have system off of test (a time of inspection) 1.3 Building owner- Sanford Fire Prevention will require (3) three phone numbers and names for after hour emergencies 1.4 All fire sprinkler vales inside the building and out shall have monitoring to the fire alarm panel as "Trouble" 1 VAo, ZIA? 0 10 The speed, reliability and value of digital communications from the company you can trust As pioneers in digital fire technology, Silent Knight delivers superior systems at an outstanding value. Our 5104 Fire Control Communicator has become the industry standard by proving itself in years of field-tested operation. This six -zone fire control communicator provides fast, reliable digital communication of fire and trouble conditions. It transmits via ordinary phone lines — eliminating the need for expensive leased line arrangements. Use it as a stand-alone, or incorporate it into your existing system.Why spec any other digital communicator? Go with the industry standard — the 5104 Fire Control Communicator from Silent Knight. For more information, please call 1-800-446-6444, or in Minnesota, call (763) 493-6435. Model 5104 Fire Control Communicator The Silent Knight Model 5104 is a six -zone fire control communicator providing digital fire reporting over ordinary telephone lines, eliminating the need for costly leased lines. It's UL 864 and NFPA 72 approved for monitoring local evacuation controls. As a stand-alone unit, it can be used to monitor: Sprinkler systems for waterflow, supervisory, and gate valve tamper conditions. Automatic fire detection systems for structures that are not required to have a fire alarm system but want property protection (e.g. to call the fire department after hours). Monitors dry contact alarms, trouble and supervisory outputs, then transmits a separate code for each. The Model 5104 is fully supervised. Its microprocessor constantly runs programs to monitor AC, standby battery, zone inputs and telephone line connections. If a fault condition is detected, it sounds a local trouble audible and reports the condition to the central station. If one of the telephone lines faults for more than 60 seconds, it will automatically switch to the other to report the failure. The communicator will signal activation, restoration and trouble conditions on any of six inputs. If an application requires a different input configuration, the individual input styles may be changed by using a Model 7181 Fire Zone Converter Module. The 7181 also allows use of two -wire type smoke detectors, instead of the normal four -wire contact type, for automatic fire detection applications. Features UL 864 Listed for NFPA 72 Central Station and Remote Supervising Station Fire Alarm System Service. FM approved. Can be used as a stand-alone or as a Slave DACT Six fully supervised inputs: one Class A (Style D) input, and five Class B (Style A) inputs. Downloadable for remote programming. Fuseless overload protection with automatic reset circuitry and fault indicators — eliminates the cause of most field calls. Dual phone line interface Automatic self tests every 24 hours with report sent to central station. Reports in SIA and most major communications formats. 60 hours of standby power. Operates on loop start phone lines ahead of the building PBX system. A single, programmable output is provided for alarm or dialer failed conditions (cannot be used for evacuation purposes). RECEIVED S 1)rT 13 2003 5104 Fire control Communicator Specifications Electrical Slave Applications - Not UL Listed Input: 24VDC from a UL Listed Fire Control Panel Total DC load: 75mA minimum at 24VDC 600mA maximum at 24VDC Current: Standby 50 MA Alarm 135 mA Stand Alone Applications Input: 120VAC 60Hz. 40 watts Standby: 12 volt 7 amp hour rechargeable battery supplied) 5230 Remote Annunciator (three maximum per system) Load: 60mA standby 120mA alarm Indicator Lights (LEDs): Power On (Green) Trouble Silenced (Yellow) Until Trouble is Cleared/Flashing = Supervisory Dialer Failure (Yellow) Telephone Line Fault (2 Red) Inside Cabinet at L1 and L2 Inputs Telephone Requirements: I k—AM x<t. ss.r. --. ANNUNCI4TOR i 6 IL FCC Registration #: AC698R-17462-AL-E RINGER EQUIVALENCE O.OB Type of Jack: RJ31X (2 required) Mechanical: Dimensions: 12.25" W x 14.51 H x 3.0" D 3 1.1 cm W x 36.8 cm H x 7.6cm D) Weight: 15 lbs. (6.75 kg) Color: Red Optional Accessories: 5230 Remote Annunciator/Programmer 5561 Download Package 7181 Fire Zone Converter Module 7860 Telephone Connecting Cord for RJ31X Jack (2 required) Communication Formats: SIA, SK 3/1, Sescoa 3/1, Contact ID, SK 4/2, Radionics BFSK Approvals: UL Listed - UL864/NFPA 72 Central and Remote Supervising Station Fire Alarm System Service. FM Approved CSFM Approved MEA - New York City ULC - Canada Model 5230 Remote Alphanumeric Annunciator The 5104 can be programmed through the use of the optional Model 5230 Remote Alphanumeric Annunciator. Programming options include: telephone numbers, reporting format, account number, loop response times (electronic retard), test time, output activation, user and installer codes. System programming is stored in a non- volatile EEPROM chip which is reprogrammable hundreds of times. The 5104 accommodates up to three remote annunciators via a four -wire connection. A quick - connect plug allows temporary connection of the annunciator for programming. The Model 5561 Downloading Package Allows for remote programming and status checking of the 5104. Includes a 3 1/2-inch disk and Silent Knight proprietary modem. Allows the installing company to view the default programming, modify it, and if necessary, troubleshoot the system. Designed to be used on an IBM or compatible PC. The downloading software also contains programs for other Silent Knight downloadable products. 5 1/4-inch disks available upon request. 5104 Fire Control Communicator UL-LISTED LOCAL FIRE CONTROL 120VAC 60 Hz Alarm Contact N.O. Typical) Trouble Contact SILENT KNIGHT MODEL 5104 Silent Knight 6 Channel Model 5230 Communicator optional) Remote Annunciator 3 max per system) 0. Tel. Line #1 To RJ31 X Tel Line #2 MODEL 5104 BLOCK DIAGRAM Slave DACT Application SILENT KNIGHT MODEL 5104 120VAC 60 Hz 6 Channel Class A Input Communicatorommunicator Max 5 waterflow devices as per NFPA 72 Class B Inputs supervised) Gate valve tamper or PIV supervisor - must connect rc normally open LC Model 6712 12VDC 7 AH Silent Knight Model 5230 optional) Remote Annunciator 3 max per system) 0 Wheelock MB-G104 2-R I I Tel. Line #2 MODEL 5104 BLOCK DIAGRAM Stand-alone Waterflow Application To RJ31X 5104 Fire Contr®I 120VAC 60 Hz Class A Input supervised) Class B Inputs supervised) Heat detectors, manual Cpullstationsand contact type smoke detectors SILENT KNIGHT MODEL 5104 6 Channel Communicator Model 6712 12VDC 7 AH Tel. Line #1 ' To RJ31X Tel. Line #2 MODEL 5104 BLOCK DIAGRAM Stand-alone Automatic Fire Detection Application For Communication Only) Wheelock MB-G10-12-R optional) ARCHITECT/ENGINEER and send the alarm signal on one or The digital communicator shall provide SPECIFICATIONS both lines without the addition of any a secondary power supply utilizing The contractor shall provide an more equipment. It shall test each rechargeable batteries. The secondary approved digital communicator to telephone line (number) at alternating supply shall be capable of supplying transmit the fire alarm and supervisory 24-hour intervals in accordance with power, under maximum normal load, and trouble signals to a central station. NFPA 72. It shall sound a local trouble for 24 hours for central station or The digital communicator shall be ULshall signal if the telephone service is proprietary applications or 60 hours for or FM listed for fire reporting a interrupted for longer than 60 seconds remote supervising station system central station and shall conform to the . and it shall transmit a signal indicating application in accordance with NFPA requirements of NFPA 72. the loss of phone line service to the 72. The digital communicator shall provide central station over the remaining phone line. A signal shall also be The communicator shall be able to transmit all signals in the Standard SIA power and necessary components for transmitted to indicate the restoral of format (Security Industry Association). six supervised detection circuits. One phone service. The shall be Class A (Style D) and five shall control/communicator shall be able to The alarm signals transmitted to the be Class B (Style A). The detection report the loss of either phone line central station shall indicate which of circuits shall accommodate sprinkler without regard to which phone line the six zones is in alarm and which flow switches, gate valve supervisory failed first. If both lines fail, a local zones are in trouble. Restoral from switches, thermal detectors and signal shall sound. alarm or trouble shall be capable of contact -type smoke detectors intermixed as desired and permitted by The control/communicator shall have communicating to Silent Knight, and other industry standard receivers. NFPA 72. the ability to send a test signal to the central station every 24 hours. The test The control/communicator shall have signal shall be able to be transmitted at the capability to supervise two a specific time of day or night by telephone lines, seize the phone line setting a program within the panel. SILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369-4927 800-446-6444 or in Minnesota 763-493-6435 FAX: 763493-6475 World Wide Web: http://www.silentknight.com MADE IN AMERICA FORM# 350349. Rev. 10/02 Copyright © 2002 Silent Knight r- PS-DA and PS -SA Conventional Pull -stations Easy to Install and Operate The PS -DAPS -SA Pull Stations are non -coded manual pull stations which provide a Fire Alarm Control Panel FACP) with a single alarm initiating input signal. The PS -DAPS -SA pull stations includes both single-action and dual -action models equipped with key lock / reset.lt was designed to meet multiple applications with the installer and end -user in mind. Its innovative design, durable construction, and multiple mounting options make the PS- DA and PS -SA simple to install, maintain, and operate. Mweb: PS -SA- Single action with 'pigtail' connections and a key lock reset. Pigtail wires are provided for con- nection to the Fire Alarm Control Panel's (FACP) initiation circuit. PS-DA - Dual action model with screw terminal connections and a key lock reset. PS-DASP - Same as PS-DA except with both English and Spanish operating instructions. TIli Featares: UL Listed CSFM Listed Meets ADA requirements Operating instructions are mold- ed into the handle along with Braille text. Made of durable Lexan Available in Spanish Key resettable Easy to Install and operate Single or dual action Surface mount box available' MDASP Speafication: Dimensions: Height: 5-1/2" (13.97 cm) Width: 4" (10.16 cm) Depth: 1-7116" (3.65 cm) Operating temperature: 32T to 120T 0°C to 49°C) Electrical: Switch Contact Rating: 0.25 A @ 30 VAC or VDC Amnodes: SB-10 Surface Mount Back -box BG-TR Trim Ring PS-DA and PS -SA c--- -- Conventional Pull -Stations Engineering Specification Manual Fire Alarm Stations shall be non -code, with a key -operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated station shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red colored LEXAN@ (or polycarbonate equivalent) with clearly visible operating instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (25.4 mm) or larger.* Stations shall be suitable for surface mounting on matching back -box SB-10; or semi -flush mounting on a standard single -gang, double -gang, or 4" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local require- ments. Manual Stations shall be Underwriters Laboratories listed. NOTE: The words "FIRE/FUEGO" on the PS-DASP shall appear on the front of the station in white letters, approximately 3/4" high. PS -SA Front View PS-DASP Front View r PS -SA- Rear Vim PS.DA Rear Vew SILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369-4927 800-446-64" or in Minnesota 763-493-6435 FAX: 763-493-6475 World Wide Web: http://www.silentknight.com MADE IN AMERICA FORM# 350241, Rev. 9/00 Copyright © 2000 Silent Knight A Honeywell Intemational Company x Features Models Available 2400/2400A Photoelectronic 2400TH Photoelectronic with Thermal 2412B/2412BA Photoelectronic 2412THB Photoelectronic with Thermal 2424 Photoelectronic 2424TH Photoelectronic with Thermal 12 or 24 volt operation Field sensitivity metering of detector to meet NFPA 72 Unique optical sensing chamber requirements Removable cover and insect screen for easy Twist -on mounting bracket with tamper option cleaning SEMS screws for easy wiring Visible LED blinks in standby, latches on in 3-year warranty alarm Optional built-in 135°F (57°C) heat sensor Sealed against dirt, insects, and back pressure Specifications Size: 3.2" (8.1 cm) h, 5.5" (13.9 cm) Sensitivity: 3.0% ± .7 ft. nominal dia. with mounting bracket; Test Features: add .5" (1.27 cm) to height for 1. Test port - Insert 0.1 inch maximum diameter allen thermal wrench or screwdriver into test port on detector Shipping Weight: 0.5 lb. (227 g) housing. Operating Temperature Range: 2. Test card - After removing detector cover, insert Thermal Models: 32°F to 100°F (0°C to 38°C) calibrated test card into test slot on screen. All Other Models: 32° F to 120° F (0° C to 49° C) 3. Test module - Using a standard voltmeter interface, Operating insert MOD40OR plug into detector's module port. Humidity Range: 10 - 93 % RH noncondensing Fulfills calibrated sensitivity test per NFPA 72. Air Velocity Rating: 3000 fpm Thermal Sensor Rating Wiring Gauge: 12 - 18 AWG, twisted pair thermal models only): 135°F fixed temperature recommended Mounting: 3'/2 " or 4" octagon box, 4" square box with plaster ring, 50, 60, 75 mm boxes Smoke Detector Spacing: On smooth ceilings (as defined in NFPA 72), spacing of 30 feet (900 sq. ft.) may be used as a guide. Other spacing may be used depending on ceiling height, high air movements, and other conditions or response requirements. restorable MFA 4 approved S, APPROVED m System Sensor 2/97 This document is not intended to be used for installation purposes. A05-194-03 General Description System Sensor 400 Series photoelectronic detectors are The 400 Series offer 6 different photoelectronic detectors specifically designed to meet the stringent performance with a variety of voltages, wiring configurations, and requirements of industrial and commercial fire detection/ thermal options. alarm systems. The design of these detectors emphasizes ease of installation and field maintenance. Electrical Specifications Control Operating Auxiliary Remote LED Current Consumption Model Product Panel Voltage Contacts Option Standby (max.) Alarm (maxi 2400 Photo Detector 2-wire 12/24 VDC No Yes 120 µA 2400TH Photo Detector w/Fixed Heat Sensor 2-wire 12/24VDC No Yes 120 µA 2412B Photo Detector 4-wire 12 VDC Yes No 120 µA 77mA 2412THB Photo Detector w/Fixed Heat Sensor 4-wire 12 VDC Yes No 120 µA 77mA 2424 Photo Detector 4-wire 24 VDC Yes No 120 µA 4lmA 2424TH Photo Detector w/Fixed Heat Sensor 4-wire 24 VDC Yes No 120 µA 41mA Must be limited by control panel Relay Contact Ratings: Resistive or inductive 60% power factor) load Alarm Contacts Form A: 2.OA ® 30 VAC/DC Form C: 2.OA ® 30 VAC/DC 0.6A @ 110 VDC, 1.0A @ 125 VAC Reset Time: 3 sec. (max.) Startup Time: 34 sec. (max.) Engineering Specifications Smoke Detector shall be a photoelectronic type (model 2400, 2412, 2424) or a combination photoelectronic/ thermal (model 2400TH, 2412TH, 2424TH) with thermal sensor.rated at 135°F as manufactured by System Sensor. Wiring connections shall be made by means of SEMS screws. The detector will have a visible LED which will blink in standby and latch on in alarm. The detector shall have a nominal sensitivity of 3% per foot as measured in the UL smoke box. The detector screen and cover should be easily removable for cleaning. It shall be possible to perform a sensitivity and functional test without the need of generating smoke. Detector circuitry shall perform a self test on the sensing chamber and internal electronics every 40 seconds. If circuitry fails, the detector LED shall stop blinking. The detector shall have a mounting bracket that allows for mounting to a 3'/2" or 4" octagon box or 4" square electrical box. Page 2 AOS-194-03 400 Series Wiring Guide I I i OPTIONAL CLASS "A" LOOP I 2400/2400TH Wiring Diagram A77-716B 24 VDC EOLRELAY 2412B/THB,2424/TH Wiring Diagram Page 3 A05-194-03 i Ordering Information Part No. Description Accessories Two -Wire Models A77-716B End of line relay for power supervision, 12/24 VDC 2400 Photoelectronic detector, 2-wire, 12/24 VDC RA40OZ Remote annunciator for 2 or 4 wire systems, 3-32V - 2400A Same as above, Canadian model Use with ion and photo detectors. Fits standard U.S. 2400TH Photoelectronic detector, 2-wire, 12/24 VDC with single gang electrical box. (See below.) built-in 135OF fixed heat sensor MOD40OR Detector sensitivity test module - Use with most Four -Wire Models analog or digital multimeters. Satisfies requirement 2412B Photoelectronic detector, 4-wire, 12 VDC, with of NFPA 72 for sensitivity testing. (See below.) auxiliary contacts RS24 Replacement insect screen for 2400, 2412B, 2424 2412BA Same as above, Canadian model RS24T Replacement insect screen for 2400TH, 2412THB and 2412THB Photoelectronic detector, 4-wire, 12 VDC, with 2424TH auxiliary contacts and integral 135°F fixed heat DUST45 Replacement protective dust cover for 400 Series sensor 2424 Photoelectronic detector, 4-wire, 24 VDC, with auxiliary contacts 2424TH Photoelectronic detector, 4-wire, 24 VDC, with auxiliary contacts and integral 135°F fixed heat sensor The MOD40OR Field Sensitivity Test Module can be used with any standard DC voltmeter or multimeter to check the sensitivity range of System Sensor's detectors (satin fees NFPA 72 requirement for sensitivity testing). RA40OZ Remote Annunciator, 3 - 32V Use with ion and photo detectors that have remote annunciator output System Sensor Worldwide Manufacturing & Distribution In Canada: In the Far East: In Italy: Telephone:905-812-0767 Telephone:852-2191-9003 Telephone:39-40-949011 Fax: 905-812-0771 Fax: 852-2736-6580 Fax: 39-40-382137 In China: Telephone: 86-29-524-6253 Fax: 86-29-524-6259 In India: In the United Kingdom: Telefax:91-11-5676815 Telephone:44-1403-276500 Fax:44-1403-276501 N Page 4 A05-194-03 Installation 3.5.2 Current ®rave Worksheet Use this worksheet to determine current requirements during alarm battery standby operation. Table 3-6: Current Draw Calculations A B C D E F G H I Device Number of Devices Current per Device Standby Current Alarm Current For each device use t is ormu a: 77zis Column x This Column Current per number of devices' 5104 1 Standby: 75 mA 75 mA Alarm: 135 mA 135 mA 5230 3 max Standby: 60 mA mA Alarm: 125 mA mA 7181 (2max.) by configuration 4-wire to 2-wire Standby: 38 mA mA Alarm: 61 mA mA Class A Style D to Class B Style B Standby: 38 mA mA Alarm: 176 mA mA Class B Style B to Class A Style D Standby: 52 mA mA Alarm: 90 mA mA Current Subtotals: 75 mA 1 35 mA Smoke Detectors b1 5 GN 5o 0, 4 o o Standby: O / 1 mA 01 A- mA Alarm: 7 7 mA 7 mA S t u T. ka tc, l-+T PS - SA I Standby: mA mA Alarm: mA 0 mA IT Ex— 5LA — Standby: mA mA Alarm: mA 0 mA v-a F it— VS— S$ WATeeLot J Standby: mA 0 mA Alarm: mA o mA Standby: mA mA Alarm: mA mA Standby: mA mA Alarm: mA mA Current Subtotals: O 1 mA 71 mA Notification Appliances mA mA mA mA mA Current Subtotals: 7S .01, mA Total current rating of all devices in system (add totals of A-C) x .001:, 0%,5 A 3'{ A Number of standby hours. (24 or 60 for NFPA 72, chapter 1, 1-5.2.5): 00 H Multiply lines D (standby current) and E. Total standby AH L4. 5 AH Alarm sounding period in hours. (For example, 5 minutes = .0833 hours) Cr653 H Multiply lines D (alarm Current) and G totals Total alarm AH i Add lines F and H. AH = Ampere Hours Total AH required I, y a*9 AH 151053 3-9 r CITY OF SANFORD FIRE DEPARTMENT FEES FOR SERVICES HONE # 407-302-1091 * FAX #: 407-330-5677 DATE: O PERMIT #: V BUSINESS NAME /PROJECT: P. ".`1 t J- I ADDRESS: PHONE NO(L/Ot— FAX NO(1/4,7 CONST. INSP. [ ] C / O INSP.:[ ] REINSPECTION [ ] PLANS REVIEW [ ] F. A. [ ] F.S. [ ] HOOD [ ] PAINT BOOTH [ ] BURN PERMIT [ ] TENT PERMIT ] TANK PERMIT [ ] OTHER [ ] TOTAL FEES: S (PER UNIT SEE BELOW) COMMENTS: Address / Bldiz. # / Unit # Square Footage Fees per Bldg. / Unit 1. 2. 3. 4. 5. 6. 7. 8. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. Fees must be paid to Sanford Building Department, 300 N. Park Ave., Sanford, FI. 32771 Phone # -407- 330-5656. Proof of Payment must be made to Fire Prevention division before any further services can take place. I certify that the above is true and correct and that I will comply with all applicable codes and ordinances of the City of Sanford, Florida. 1 Sanford Fire Prevention Division Applicant's Signature