HomeMy WebLinkAbout102 Morrison Ave 95-3198, 96-79, 96-71, 96-43 New SFHZONE
CONTRACTOR
DATE S
ADDRESS
jS U LDPHONE #
LOCATION
OWNER ((
ADDRESS
PHONE #
PLUMING CONTRACTOR
ADDRESS
PHONE #
ELECTRICAL CONTRACTOR SZ C.`li(' iC p C .
ADDRESS
PHONE #
K-0/25
S
L-% MECHANICAL CONTRACTOR
ADDRESS
PHONE #
MISCELLANEOUS CONTRACTOR
ADDRESS
SEPTIC TANK PERMIT NO.
SOIL TEST REQUIREMENTS O
FINISHED FLOOR
ELEVATION REQUIREMENTS (__)
ARCHITECTURAL APPROVAL DATE:
SUBDIVISION: /Gc Ae aj':s
JOB Z
COST $
FEE $
STATE NOc C"
FEE $ 6-7
FEE $
FEE
LOT NO.
BLOCK:
SECTION:
SQUARE FEET:
MODEL:
OCCUPANCY CLASS:
INSPECTIONS
TYPE DATE OK JREJECT BY.
FEE $ ENERGY SECT. EPI:
CERTIFICATE OF OCCUPANCY
ISSUED # I DATE:
FINAL DATE
r .
CIRTIPICATE OF OCCUPANCY J COMPLETION
This is to certify that the building lo4ssted at
102 MORRISON All for
which permit 95-0,000sipR has heretofore been issued on iOHO jA5
has been completed according to plans and specifications filed in the
office of the Build' g Off' ial pr' r to the --Issuance of said building
permit, to wit as ,complies with all the
building, plumbing, electri 1, zoning and subdivision regulations
ordinances of the City of Sanford and with the provisions of these
regulations.
STAFF APPROVAL_ Subdivision Re
BUILDING: A A/s-
ZONING:
Finaled
Inspected
UTILITIES:
Water f'
r
Lines I_'i
Meter
Set
Reclaimed
Water _A,
ENGINEERING•
Drainage
Maintenance
Bond _
PUBLIC WORKS:
Street
Name
Signs
Storm
Sewer
Street
Work
WATER -SEWER IMPACT FEES
01-APPLCTN FEE -BUILDING
01-FIRE IMPACT - RESIDENT
01-LIBRARY IMPACT FEE
01-OPEN SPACE
01-POLICE IMPACT - RESID
01-RADON GAS TAX FEE
Ol-ROAD IMPACT FEES
01-RECOVERY FD/CERT. PGM.
FIRE:
Inspected
Sewer
Lines
1 Sewer
Tap
Stree
Paved
DATE
10/02/95
10/02/95
10/02/95
10/02/95
10/02/95
10/02/95
10/02/95
10/02/95
ly: Yes No
M APPROVAL
9%
AMOUNT
7/2y80
10.00
59.27
54.00
279.61
91.93
9.06
473.00
9.06
PAGE: 2
This is to certify that the building located at
102 MORRISON AV for
which permit 95-00003128 has heretofore been issued on 1OZ02/95
has been completed according to plans and specifications filed in the
office of the Building ffi 1 pr r to the.issuance of said building
permit, to wit asoff" / o a_'., G_e - complies with all the building,
plumbing, electrical, zoning and subdivision regulations ordinances
of the City of Sanford and with the provisions of these regulations_
STAFF
APPROVAL Subdivision Regulations „Apply: Yes No 01-
SCHOOL IMPACT FEE 10/02/95 639.00`, V
T µ,_ OWNER
BUI- DIN OFFICIAL / DE/
r DATE STARTED: T
CITY OF SANFORD, FLORIDA
Request for Mimi inspection for
Cerfiflca, of Occupancy
ADDRESS:
The Building Department has prepared a certificate of occupancy fortheabovelocationandisrequestingafinalinspectionbyyourdepartment.
After your inspection, please come to the Building Department to
sign -off on the Certificate of Occupancy, or submit a certificateofoccupancyaddendumifithasbeendenied.
Your prompt attention will be appreciated. Thank you.
DISTRIBUTION: Engineering Department
Fire
Public Works
Utilities/Cross Connection
Zoning
a 0o 0o R a 3
DATE STARTED: G
l
CITY OF SANFORD. FLORIDA
Mt A x Request for Final inspection for. __
ierfifi a of O.Gcupancy
ADDRESS: C/a
The Building Department has prepared a certificate of occupancy fortheabovelocationandisrequestingafinalinspectionbyyourdepartment. 11
After your inspection, please come to the Building Department tosign -off on the Certificate of Occupancy, or submit a certificateofoccupancyaddendumifithasbeendenied.
Your prompt attention will be appreciated. Thank you.
DISTRIBUTION: Engineering Department
Fire
Public Works
Utilities/Cross Connection
Zoning
I DATE STARTED:
CITY OF SANFORD FLORIDA
t '' ,
teal IS eciion forRequestforF"
Cortlflca of vpaticy
ADDRESS: / U 0,--r/sbn A6a-
The Building Department has prepared a certificate of occupancy fortheabovelocationandisrequestingafinalinspectionbyyourdepartment.
After your inspection, please come to the Building Department to
sign -off on the Certificate of Occupancy, or submit a certificate
of occupancy addendum if it has been denied.
Your prompt attention will be appreciated. Thank you.
DISTRIBUTION: Engineering Department
Fire
Public Works v
Utilities/Cross Connection
Zoning
ENTERED JUN 2 3 1995
CONTRACT FOR SALE AND pURCHASls
1 PARTIES: TUDA,_
Qf-1_08 M3.1R 49-01 SUI'I'1,_,ZU9:L; [ '):'AM0Wl-L S V A INM r'1,oR1_pA 3z701
and Tl: R. FR T N n— FAMED) M, R A-,\1 M F.L (I3UYls'R)
of I-hkF Nr.weck r i-(__5, UIIONE, :Y "
hereby "agree that_ the Seller hal l' sell and the Buyc.r(s) tibal l Puy the
following (Proper(y) upon the following terms and conait ons which
INCLUDE THE STANDARDS FOR REAL ESTATE `i'RANSACTIONS set forth below and
on the reverse side hereof or .at cached heretci (Standards) including aany
Addenaums. i
Z. PUSCRIPTION: (a) Legal description of i'roperty located in Seminole
County Florida, LOT # .l" MONROE MEADOWS, PH 46, PGS 1G & 17 3
b) Street address of 1' •opert.y teeing conveyed:
9"17 Sanford, FL. 32773.
e ) Model o - I'slr,valion_,
3. PURCiiASE I'IticE ANi) METHOD OF i"AYMENT:
Total Purctaa-e Price
Deposit:ZM-.-_Payable to SUDA, INC. ESCROW ACCOUNT**
J $
Approximate principal amount'. of Mcirtt;agcdd to be obtained $ &%5"
Additional Deposit payment schedule: a4. -
Approximate balance of funds to be paiq at closing (cash $
or cashier's check)
l "nds to be released to Suda, l e. upon loan approval and prior to
colts truction.
4. THIS CONTRACT CONTINGENT UPON t It e Boyer(s) qualifying for: F
a
a) ( ) V.A.
b) ( ) CON VENTiONA],
c) ( ) CONSTRUCT
5. IJUYI R TO APPLY FOR MOI ' GA(als WI'1'1ll N F 1 VIs (5) WORKING DAY"S and obtain a
written loan commitment for the loam within days of date of this
Contract. Buyer will use all reasonable diligence to obtain the loam;
commitment.and thereafter, to meet the terms and conditions of the
commitment and to close the loan. if Buyer(s) fails to obta n' he' -roan
commitment, and promptly notifies Seller in writing, or after diligent
effort fails to meet the terms and conditions of the commitment within
the time staled for obtaining the corm i'Werrt, then either party may
cancel the Contract rnI liuyer(s) shnQ be returned the de;posit(s). 3
Loan approval is is not contingent. Refer to Addendum A -a for
contingency details. Iiu,yer(s) agree they will"do nothing to jepoedixe
their ability to obtain written Ioan approval, such as, b'"t. not limited
to, incurring additional debl(s), or voluntarily resigning from their
job,' or changing employers without notification to the lender.
6. MORTGAGi; HOLDER TO HE APPROVED UY SELLER.
7. TIMEAOR ACCEPTANCE: If .this Con, is"not executed aria delivered by
Seller and Buyer(s) on.or"bcC6re" __ the aforesaid deposit
i Shall be returned- to Buy-er(s)'-and" this agreement s'haIJ tie null` and
I void. The date of this Contract, for purposes of -performance shall ;be
regarded ;as; the date when the last: ne of the Seller and lluy,er(s) has
Signed this Con -tract
U. CLOSING DATE: This Contract sha.l I be cl sed end the deed and other
closing papers delivered on or beforf X-/ , unless
extended byother provisions of this Contract. ThiA' sale hall be. closed
in the office DETERMINED BY SELLER. s 0.'
CONVEYANCE: Seller shall convey title to the aforesaid property to the Buyer(
s) by GENERAL" WARRANTY DK D subject to matter;; contained in this ' Contract
and taxes for the year.or closing,. 10.
RES'TRICTIONS AND EASEMENTS: The I3uyer(s), shal l take t i t.le subject to; a
a)
Zoning and/or restrictions and prohibitions imp6sed by governing g Authority, (
h) Restrict ions appearing on the plat or impose& by the Developer, (
c) other to include Covenant Restrictions and lay -haws of j Monroe
Meadows Homeowners Association. II.
SPECILAL CLAUSES: -------- SIDE AbDENDUM, A--1 AND A-Z---------------- --- 12.
FAILURE OF PERFORMANCE: if Buyer(s) fitils to perform this Contract within"
the time specified (including payment of all deposits hereunder),
the deposits paid by the Buyhr(s) may be retained by or for
the account of the Seller is agreed upon liquidated damages, consideration
for the execution of this Contract and in full k settlement
of .any claims; whereupon Buyer(s) and Set ler shall be relieved
of all obligations under this Contract. If;-forany reason p
CITY OF SANFORD, FLORIDA
PERMIT NO. lU _q3 DATE / D f5 -mil 5
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO INSTALL THE
FOLLOWING H.A.R.V. MECHANICAL EQUIPMENT:
OWNER'S NAME
ADDRESS OF JOB xa4
MECHANICAL CONTR. /4 -ew 14
RESIDENTIAL -' + COMMERCIAL
Subject to rules and regulations of Sanford mechanical code.
NATURE OF WORK
COMPETENCY CARD NO./
Fi
sb .-
0" ,SA iyOia.'YRI®A s
i PERMIT No pATE
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO INSTALL THE FOL.
LOWING ELECTRICAL WORK -
OWNER'S NAMF__ 1 t l 00 1 n C-
ADDRESS OF,Jo*I S Monroe Meodov s' I0z Mornsoh ELEC.
CONTR PU- I' - `AdIt f RosidontiaL_LNoo n idontieL__ Subjoct
to rulos and rogu9ations of the, city and national eloctric Coda. N,,
rnbor II AMOUNT Chance
of Service Resi omn
4obile
Home Factory
Built Ilousinft Vew
Residential 0-100 A 101-
200 A 201
Amp a Jew
Commercial ign
biidisy
Offkw S
e r-- e Ser—
vice above
er5
viceTOTAL
Most
ehkias STATE
COMPETENCY NO. Dv
CITY OF SANFORD.
PERMIT NO (0 — -1 S - -
FLORIDA
DATE
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO INSTALL THE FOL.
LOWING PLUMBING WORK:
OWNER'S NAME Silda ,—Te
ADDRESS OF JOB t/n2 Morrison AV --? 9w 8m X-A- ,ree
PLUMBING CONTR. yG ' s. Comm.
Meadows
Subject to rules and regulations of Sanford plumbing code.
Residential: I Number
Alteration, Addition, Repair
Amount
New Residential:
One Water Closet
Additional Water Closet
Commercial:
Fixtures. Floor Drain, Trap --
Sewerr --
Water Piping
Gas Piping
Factory -built housing
Mobile Home
I
Application Fee
I
0
Minimum Commercial Permit: S25. oo Total ti-7 nr'
I
COMPETENCY CARD No. RFnn5nS73
I
CITY OF SANFORD, FLORIDA
APPLICATION FOR BUILDING PERMIT
Q
b
U
O
O
t
a
a
0
M
PERMIT ADDRESS 116Q) rrl / 1V PERMIT NUMBER
Total Contract Price of Job 000 Total Sq. Ft. >Z
Describe Work _LQnStrUc+ SFK
Type of Construction C-C3
Number of Stories 1 Number of Dwellings
Occupancy: Residential V/ Commercial
Flood Prone (YES) (NO)
Zoning r}1R-1 14 CAR 2
Industrial
LEGAL DESCRIPTION (please attach printout from Seminole County)
TAX I.D. NUMBER
OWNER PHONE NUMBER
ADDRESSHA r in in
CITY JaniQnfe S STATE ZIP
TITLE HOLDER (IF OTHER THAN OWNER)
ADDRESS
CITY STATE ZIP
BONDING COMPANY
ADDRESS
CITY STATE ZIP
ARCHI
ADDRE
CITY
MORTGAGE LENDER
ADDRESS
CITY STATE ZIP
CONTRACTOR PHONE NUMBER
ADDRESS VA Min ST. LICENSE NUMBER co 7- S 1013
CITY Al STATE F( ZIP 3 3()j
Application is hereby made to obtain a permit to do the work and installations as
indicated. I certify that no work or installation has commenced prior to the issuance
of a permit and that all work will be performed to meet standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured
for ELECTRICAL, PLUMBING, MECHANICAL, SIGNS, POOLS, ETC.
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that
all work will be done in compliance with all applicable laws regulating construction
and zoning. A COPY OF THE RECORDED COPY OF THENOTICEOF COMMENCEMENT WILL BE POSTED ON
THE JOB SITE WITH PERMITS NO LATER THAN SEVEN (7) DAYS AFTER THE PERMIT HAS BEEN ISSUED.
FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR THE
IMPROVEMENTS TO YOUR PROPERTY. IF,.YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR
LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE:
In addition to the requirements of this permit, there may be additional restrictions
applicable to this property that may be,found in the public records of this
county, and there may be additional permits required from other governmental entities
such as water management districts, state agencies, or federal agencies. is
r
c a
3 O
Z
H
H fA
r-I i - (
0 w r-
O 14
O 1
0 a) a 'Z
a4 P CCEPTANCE
OF PERMIT IS VERIFICATION THAT I WILL NOTIFY THE OWNER OF THE PROPERTY OF HE
REQUIREMENTS OF FI^IDA LIEN LAW, FS713. 5
1<
cD o m
En a o
n Signature
of Owner/A ent & e ' gnat.ure of Contractor & Date o w "< SudU.
Willi I ° er, %v r . Type
or Print Owner/Agent Name Type or Print Contractor's Name 3 (
D i +
O ro
gnature
of N t ry1& Date' S'g ature of Nota & Date's 4Vae
1
OFFICIAL
SEAA21
BONNIE
R SW(E BONNIE
R. LA'' Notary Public - Florida z`
SEMINOIE COUNT rNotaPublic - FMy Comm.
Expires Oct. 28 1996 SEM NOLECOUa;'-'' s MyComm. Expires Ormy Comps ft CC 2391t2114YCorM1. CC Application ApprovedBY:
Date - FEES: Building -" _ Radon
Police ? . 3 Fire -4I, 7 Open Space Road
Impact .D plicattiion ^ PERMIT VALIDATION: CHECK
CASH DATE b BY ORIGINAL (BUILDING) YELLOW (
CUSTOMER) PINK (COUNTY TAX OFFICE) GOLD (CO. ADMIN) THIS APPLICATION USED
FOR WORK VALUED $2500.00 OR MORE
r
Department of Community AffairsI1airs N; 5_^5
FLORIDA ENERGYEFFICIENCY 1Lam1 G CONSTRUCTIONCODEORBUILDING
OR _;=-93 Resid c Component Prescriptive MethodA RALCENTRAL
PROjECT NAME:
AND ADDRESS: WJ Of I Q+ 1 'C..
Sanford FL 3a7 3
P :-RrN! ) r _!'•i.
I "
G'iL p' .'...1__ I fir- T r__
OFFICE: ,0 aj& !ZONE: = - 1 S t
r 5 a LV1G
61
1 . New construction or addition 1. New Construction
family detached or Multifamily attached 2. Single -Family
Multifamily -No.
if Multifamily, is this a worst case (yes/no) 4. floor1.
7 , Porch overhang length (ft.) 7. 0.
A. Glassareaand type;
Floor typerr - J insulation:
Slabi...4.
on grade _ perimeter)
10,Net Wall type area and insulation:
r r_I .: ::r :_ _ 'i r '.. . ._. . Wood r : - v _..,. .-•! _. . r _ _. -_ '-: _' 1 •_! 0 1 2 •-, 3-+ . Adjacent: frame (insulation 'ram , t s '-'I !
t __ •_-. _.......
1!.Ceiling type area and insulation:
ii. Under i r,._ ,,.., _ '_ y
distribution
I
L_+'!J .L 1l:h b•V s t+='jlI i _ _._ Central A:
SEER: 10
Heating System: Type: Heat Pump
I
i -:- r:V G. _._..._.....
15.Hot water system:
1G.Hot.Water Credits: (HR-Heat Recovery,
Ir, _ - - - - Heati Pump)
I1 i iIt•ra-t•i.Gi`! practice: 1, 2 +t1' _.
H V A j_ Credits I•. t, F -C= i. i i g Fan, C 1V - t_ r O s r_ 1 I t
HF-Whole house fan, RD-Attic radiant
barrier, Itr:_-t' a .t t i .=+_+•i-I(_ .j
Total19.
EPI (must not exceed 100 points)
a. Total As Built points
b. Me points
1 _
16. Type: : Electric
r 0-11
t_ t;-•:r: fi_.t_. 4 -___-
Hr'i-'e1_+ certify thatt• the plans and i Review of - the plans ct; Il _s pt=r t_ i •I 1 c•_t L1o1-1 `-.
specifications covered by this cal u-• 1 co''rTi-cd by t-hi::=: calculation indicates
at.ion are in=s_!ii; 3 Inca +.',,ith .;he 1 compliance with 1.h;= Florida EIiE']"gy
lid` E _e _t' 1 Code, rBeforeconstruction t'„cti_n is completed this
building will be ii`tspeaLr.`_d for compliance
in iaccordance with Section ATE:,
L 9 S:-; F.S. p i
here:,:'
certify that this building isin compliancewiththeFloridaEpergy. r
code. ,
1
NER/
AGENT; ; BUILDING OFFICIAL: A,t_: __ _(i_V E t_
I 1
rir.TE L_
SUMMER CALCULATIONS
BASE === AS -BUILT ===
ALASS----------------
RIEN AREA x BSPM = POINTS TYPE SC ORIEN AREA x SPM x SOF = POINTS
8N540002.2
E 4800 82.2
4438 8
3945.6 1
S8L CLR N 160 51.0
S8L CLR N 38.0 51.0
S8L CLR E 32.0 109.2
91 739
93 1792 7
83 2888.7
S8L CLR E 16.0 109.2 83 1444 4
S 72.00 82.2 5918.4 SGL CLR S 32.0 100.2 90 2882.8
W 39.00 82.2 3205 8
S8L CLR S 0 40 0 l02 S6L
CLR W 32.0 109.2 91
3661 2 83
2888.7 S8L
CLR W 7.0 109.2 77 587 9 l5
x COND FLOOR / TOTAL GLASS ADJ x GLASS = ADJ GLASS GLASS AREA
AREA FACTOR POINTS POINTS POINTS l5
1,358 00 213.00 956 17,508 60 16,744.14 16;886 l4 ON
GLASS ------------ AREA
x BSPM =' POINTS TYPE R-VALUE AREA x SPM = POINTS 4ALLS----------------
Ext
978.0 1.0 978.0 Ext NormWtBlock In 3.0 978.0 1.40 1369.2 Adj
220.0 , .7 164.0 Adj Wood Frame ll 0 220.0 70 154 0 OORS----------------
Ext
20.0 4.8 900 Ext Wood 20.0 7.20 144 {) AN
1.6 28.8 Adj Wood 18.0 2.40 43.2 CEILINGS-------------
A
1358.0 .6 814.8 Under Attic 22.0 1358.0 90 1222.2 i- -
LOORS --------------- Slb
166.0 -31.8 5278.8 Slab -on -Grade .0 l66,0 31,90 -5295 4 INFILTRATION---------
1358.
0 10.9 i ===============================================================================
14802.
2 Practice #2 1358,0 16,90 14802.2 TOTAL
SUMMER POINTS 28,
339.14 29,325.54 TOTAL
x SYSTEM = COOLING TOTAL x CAP x DUCT x SYSTEM x CREDIT = COOLING j3UM
PTS ' MULT POINTS C8MPON RATIO MULT MULT MULT POINTS 28,
339 l4 .37 l0,485 48 1 29,325.54 1.00 l .l00 .340 1,000 10,967.75
WINTER CALCULATIONS
BASE === AS -BUILT ===
GLASS ----------------
JRIEN AREA x BWPM = POINTS TYPE SC ORIEN AREA x WPM x WOF POINTS
N 54.00 -3 4 183,6 S8L CLR N l6 0 9 6
S8L CLR N 38.0 9.6
1.05
1.04
161 7
379.4.
E 48.00 -3 4 163.2 S6L CLR E 32.0 -2 2 06 4 2
S8L CLR E 16.0 -2 2 06 2 l
S 72.00 -3 4 244.8 S8L CLR S 32.0 -10 9 94 328 5
S6L CLR S 40.0 -10.9 95 4l5 0
W 39 00 -3 4 132 6 SGL CLR W 32.0 -2 2
S8L CLR W 7.0 -2 2
06
26
4.2
4.0
l5 x COND. FLOOR / TOTAL GLASS ADJ. x GLASS = ADJ GLASS GLASS
AREA AREA FACTOR POINTS POINTS POI04TS
5 1,358 00 213.00 956 -724 20 -692 58 1 209 02
NON GLASS ------------
AREA x BWPM = POINTS TYPE R-VALUE AREA x WPM POINTS
WALLS----------------
Ext 978.0 1.1 1075 8 Ext NormWtBlock In 3.0 978.0 3.80 3716.4
Adj 220.0 j.8 396.0 Adj Wood Frame ll 0 220.0 1.80 396 0
DOORS----------------
Ext 20.0 5.1 102.0 Ext Wood 20.0 7.60 l52 O
Adj 18.0 4.0 72.0 Adj Wood l8 0 5.90 106.2
CEILINGS -------------
UA 1358 0 .6 814.8 Under Attic 22.0 1358 0 90 1222.2
FLOORS---------------
Sib 166.0 -1 9 315 4 Slab -on -Grade .O 166.0 2.50 415.O
INFILTRATION--------- 1
1358 O 4.1 5567,8 Practice #2 l358 0 4.10 5567 8
TOTAL WINTER POINTS
7,020.42 ll,36658
TOTAL x SYSTEM = HEATING TOTAL x QAP x DUCT x SYSTEM x CREDIT = HEATING
WIN PTS MULT POINTS COMPON RATIO MULT MULT MULT POINTS
7'O20 42 1.10 7,722 46 1 11,365.58 1,00 1.100 500 1.000 6,2062
J' .L..y y }4. 1:1...:: •y.:- J J1 1 .1 i J L}, 4 1 y 1.; ..y..•...1: ..1: .._ j.. .. i:-'..:.i..J.., ,..J..y.},
y..,..:k.: k..t.: r..t.. k-.T..J..•} .i. n..L :.-J ....y. .}..,..;'. ,..1-.1..-7:.-}-..,..y-. ?..t.....,..,..t-'{ ..#. a..t f. •..,-'.3 y,.:..: }. .1...-}...-k..,....k::1....C t..1.:1. .L:.y.::F...l...i..y..y..•..;: .y.
t.: k..•r....y..,..•}• k'F-.y.: k-t.: k. a.
WATER HEATING -
y y. 4..y..J: i } 1 J. J I:..1: :'--y--a: ..I...y.:; ..y. ..L...4:.1..a; .y..•..:. y..l..y..y..1.:a t 1 y..y..y .y..y.. ..1. :i: .:. .} L••.L•J:.J:..i:
t.:!..
i-:1-..L.. ;:.- .1..J:..}.. .1' yf..q•.:}..-k..•..'a,•.a.:o-..y..... .•,..•r....4it. y..,..•,..y..,.:,..i..,..y:.l:•^...•.:,.:y..t..t.:;..i'.:;..•}•.: r..•r. ...#:.{.a.:;..t.:;..t..y.. •k.....p..,.: ,.: k.:•,. ..y.: k.., y.. {•.: p.: p.
OF' M _' TOTAL v TANK _LM__ " TANK , M »» i - y_ i
i
v::
90 1.000, , r', v +
J
a: '
a J: ._ •
J-:i:.y-.:: r.....
t... 1. ,
1: -.;: ::: :: -.;: ,:: .:: f....., ..
7 •: •, BASE
J: :!:,;..:
L, :L..,.::..: ..l..y:: ._ .: ...1: -.L• ::., s: ::.-,i: .-s: ,;:.J::;....L.:;:. r ,..
i .I. r
r , r , , r-'i'- , r r r r , , , :!'- i :i'- :(.: ! , AS -
BUILT- y...
i.. ;L-_-•1--!: :i::.:-.i:.l. •1..::--J: -J:-.:::.i:..L• k..
i , , r-t , r r 1...•.....
ri:iG HEATING1 p '.:
fib HE ;..; 1 'WATER TOTAL HOT WATER TOTAL POINTS
r :'
r
1
L • •J: •: J: -.:; v - •.: : is .L• -.i.• .i: :.:.,..i. I
I
9
p
i
p
d
x
1
ENERGY GUIDE
l
For detailed information
of the EPI rating number
or for any ITEM listed,
ask your Builder for
DCA Form 600A-93
or Form 600B-93
EPI= 95 8
0 10 20 30 40 50 60 70 80 90 100
X--|
The maximum allowable EPI is 100 The lower the EPI the more efficient the home
RESIDENTIAL ENERGY PERFORMANCE RATING SHEET
ITEM' HOME VALUE Low Efficiency High Efficiency
SIN8L CLR DBL TINT
WINDOWS Sinole Clear |X--------------------|
HEATIN8 SYSTEM .....
Electric COP/HSPF ..6 8
Gas AFUE............ 0 00
WATER HEATER ..........
Electric EF.............. 0 9O
Gas EF ...........0 00
Solar EF .........
OTHER FEATURES... ....... . .
R-l0 R-30
X--------|
R-0 R-7
X--------|
X--------------------|
10.0 SEER 17.0
X------------- 7------ |
9.7 EER 16 0
5.8 HSPF 12 0
X--------------------|
0,78 AFUE 0 90
0 88 0 96
X----------------|
0 54 0 90
0.40 0.80
I certify that these energy saving features required for the Florida
Energy Code have been installed in this house
Builder
J
Address: 1 lU 0/) Signature Date _
z 1
City/Zip_LK 1Q___//______
Florida Energy Code for Building Construction - lg93
Florida Department of Community Affairs FL-EPL CARD93
t R'='. fl{li Il.,l .i !, [ ) a. S )j_j-i) {.-1 99=4
WHOLE Hiaj._j=;E
HEAT GAIN HEAT LOSS CALCULATIONnLCLnTIO`USING r L ti rE _) DATA Fi LE_ AASED ON A.
C.C.A. MANUALj - SEVENTH EDITION (_ 1986 6 ADDRESS lUm.
orr«cm X . CITY Y: ('' OWNER:
Its: CONT.. E =.
AIR INC. Cond Fir Area;
1368 SF * GLASSAF RATIO 1S.7% * House Faces: Nortl Climatic Conditions & Design
Conditions Geographical Location : Florida
1 Sanford I f = -_. Latitude Elevation
1 29 Deg. / + 4 _ L Sea Level Outdoor Su,•i,;,
te.' Dry Bulb 1 93 Deg. Outdoor Summer Wet
Bulb 1 76 Outdoor ::rritfrf`Fr
Hum. Ratio Gr/LL 1 ( CD_ indoor ooSummer Re
la l i . e Hum. . ; _ indoor Summer pry BulLb
76 Deg. F indoor Summer jret Bull:-'
1 62.3 Deg. F @ r':Rj G; Lb Summer Daily Range 1
17 Deg. F Summer .±_.,: (User j. = i)
T i.1_ r• ' f i _T )
1 20 Deg 4: HEATING S(_'Mi•
1f='RY 1 . 1'__]4A DDT a: COOLING SUMMARY li'1AF;.'Y SUBTOTALOT97 -: - !STRUCTURE
STr,T SENSIBLE 19184.57 OCCUPANT/APPLIANCE 3000.010
DUCT LOSS 1648,60 !
DUCT GAIN 2218.46 TOTAL i_OS _,!BTUH
34620.66 ;T Ti, _-.STB 24403.03 O j HL_ LATENT
3279.92 20% J:'[_RSIi_E
FACTOR 6924, i 120t:• =:ENS.OVR=::_::.E I-IR _i.:= 0 I, ACTUAL 20;OVERSIZE: 41S44.
79 t_E _. T 2 rOVERSIZE: 29283.64 EQUIPMENT QELECTION EQT r• Ar••
OF %'f%
Zf ----- H____-_- -_E/y__---- HT=INPUT
HTG OUTPUT TSF" SF — SENSIBLE LATENT CLG T C
T AL L. . TC.1rVAGE• EEC'-----CLGCFt'' J4 -__
TYPE - --- NOTES: t
LOAD CALCULATION *
3LASE
Type Shdg Sc OvHg Botm Hgt Area Loss/Btuh Gain/Btuh
N No Shd Fctr S.C.N S l 1.5 8 n/a 16.00 739.20 496.00
PA No Shd Fctr S.C. N S l 1.5 10 n/a 38.00 1755 6O 1178 00
S Shaded Area S.C.N.S.l Ks ll 7.2 31.64 980.84
S Solar Area S.C.N S l 36' 17.28
S T Area Loss S.C. N S l 32.00 1478.40
S Shaded Area S.C. N S, l 1.6 13 6.2 26.58 823 98
S Solar Area S.C.N S l 13 42 644 l6
S T Area Loss S C. N.S. l 40.00 1848.00
E Shaded Area S.C.N.S. l 15 5 4 4 60 142.60
E Solar Area S.C. N.S.l 27 40 2438 60
E T Area Loss S.C. N S, l 32.00 1478 4O
E Shaded Area S.C. N S l Ps 5 4 2 30 71 30
R Solar Area S.C. N S l 13 70 1219 30
E T Area Loss S.C. N S l 16.00 709,20
W Shaded Area S.C. N S l V5 5 4 4 60 142 GO
W Solar Area S.C. N S l 27 40 2438 60
W T Area Loss S.C. N.S.l 32.00 1478.0)
W Shaded Area S'C N S l 1.6 4 3 1.34 41.54
W Solar Area S.C.N.S. l 5.66 503 74
W T Area Loss S.C. N.S. l 7.00 323 40
Infiltration Winter Htm 22.26 ) x 213.00 4741.38
Infiltration Summer Htm 5.57 ) x 213 O0 1186.41
R-Value Area Loss/Btuh 8ain/Btuh
WA L L S----------------------------------------------------------------------
N/W C.B. - Int Insul Ext. 3 978.00 7824.00 3227.40
Wood Stud - Adj. ll 210.00 792.00 286.00
SUBTOTALS: 1198.00 8616.00 303.4O
DO O R S----------------------------------------------------------------------
SoIid Core/Wood Ext. 0 20.00 570.00 218.00
Solid Core/Wood Adj 0 18.00 399.60 64.80
Infiltration Minter Htm( 22.26 ) x 38.00 845 88
Infiltration ;Summer Htm( 5.57 ) x 38 00 211.66
SUBTOTALS; 38.00 1815.48 494.46
CE I L I N G S
Under Attic 22 1358 00 2580.20 2851.80
FL O O R S--------------
Slab on Grade 0 166.00 Lin.Ft. 6378.40 000.00
TOTAL STRUCTURE SENSIBLE
32972 06 19184.57
PLAT OF BOUNDARY SUP K for:
DESCRIPTION: L=r -' e->e2 t"10NR0 M DOWS
RECORDED INPL.4TBOOK 4-=; PAGE(S) 16 &L 17 PUBLIC RECORDS OF `_ minofe COUNTY FLORIDA J
Y
1
t
r
N.Cn 27' 23"W. 50.17
O UT lt_ITY E o sEM2=hiT
Z c.
0
n
N
I -
a
N
p N,ClJ° 27' " W, sc:D)• 17' p
J 'u Q
V
Q t iOQFZ 1s0.1 A\/ E N U oo z 23 vv
rL000 Cn -11c FcdcrN3SOCdonc;u i'cdc r::l Emcc ,cncy
v
l/
Jjiar,ayc:nc"L A cncy Flood nsurance
race :nap, the propn_VCy :, cc
snul+n acrcon DOGS 240Y L:IS
ictlin chc 100 year food ,J
na za rd area. - 7L:e^i in Lone 'c"
ommunicy Panel No. 120289 o,0438
t ec live Dote: 5 -S• gf .