Loading...
HomeMy WebLinkAbout2201 WP Ball Blvd 05-260 New Constrction Petcoaao1 wp �� U5-2(.d NOV 17- E',__�� ZU Z W rn w 2 I- Z 0 W J Q W 0 Y }C W Z 0 0 C n 0 f- ry 0 FL fn Z 0 Z W 0 W Ul U W Z C Q 0LU U U 0 Y) Q� Y) } ZZ Q 0 IL o� 0 Iw U i_ z 1= Q W W 2 F- LL >_ wLL I- >0 Z :C ca r V) 0 Le OJ �a z cq 0 Ua • ARCH. DWG. ABBREVIATIONS AND SYMBOLS MED. MEDIUM L ANGLE MEMB. MEMBRANE ® AT MET. METAL CENTERLINE MFR. MANUFACTURER # POUND OR NUMBER MIN. MIMIMUM ACT. ACOUSTICAL CEILING TILE MISC. MISCELLANEOUS ADJ. ADJUSTABLE M.O. MASONRY. OPENING AL ALUMINUM M.R. MOISTURE RESISTANT APPROX. APPROXIMATE MTD. MOUNTED ARCH. ARCHITECTURAL N. NORTH ASPH. ASPHALT N.I.C. NOT IN CONTRACT B.C. BACK OF CURB NO. NUMBER BD. BOARD NOM. NOMINAL BITUM. BITUMINOUS N.T.S. NOT TO SCALE BLDC. BUILDING O.A. OVERALL BILK. BLOCK OBS. OBSCURE BM. BEAM O.C. ON CENTER B.O. BOTTOM OF U.D. OUTSIDE DIMENSION CAB, CABINET O.G. OPAQUE GLAZING CEM. CEMENT O.H. OVERHANG CER. CERAMIC OPNG. OPENING C.I. CAST IRON OPP. OPPOSITE C.F. COLD FORMED PRCST. PRE -CAST C.G. CORNER GUARD PL, PLATE C.J. CONTROL JOINT P. LAM. PLASTIC LAMINATE CLG, CEILING PLAS, PLASTER Mo. CAULKING PLYWD. PLYWOOD CLR. CLEAR P.O.C. POINT OF CONNECTION CMU CONCRETE MASONRY UNIT PR. PAIR C.O. CASED OPENING PR. TR. PRESSURE TREATED COL. COLUMN P.S.F.F. PREFAB. STRUC. STL FABR. CONC. CONCRETE PT, POINT CONN. CONNECTION PTD. PAINTED CONST. CONSTRUCTION Q.T. QUARRY TILE CONT. CONTINUOUS R. RISER CORR. CORRIDOR RAD. RADIUS CTSK. COUNTERSUNK R.D. ROOF DRAIN CNTR. COUNTER REF. REFERENCE C. F. CERAMIC TILE REFR. REFRIGERATOR CTR. CENTER REINF REINFORCED D DEPTH REQD REQUIRED DBL. DOUBLE RESIL RESILIENT DEPT. DEPARTMENT RET. RETAINING D.F. DRINKING FOUNTAIN RM. ROOM DET. DETAIL R.O. ROUGH OPENING DIA. DIAMETER R.T.U. HVAC UNIT DIM. DIMENSION RWC RAINWATER CONDUCTOR DISP. DISPENSER S. SOUTH DN. DOWN S.C. SOLID CORE D.O. DOOR OPENING SCHED. SCHEDULED DR. DOOR SHT. SHEEr DWR. DRAWER S.J. SAWCUT JOINT DS. DOWNSPOUT SIM. SIMILAR DWG. DRAWING SPEC. SPECIFICATION E. EAST SPECD. SPECIFIED (SECTION) EA. EACH S.ST. STAINLESS STEEL E.I.F.S. EXTERIOR INSUL & FINISH SYSTEM STD. STANDARD E.J. EXPANSION JOINT SrL. STEEL EL. ELEVATION STOR. STORAGE ELEC, ELECTRICAL STRUC, STRUCTURAL EMER. EMERGENCY SUSP. SUSPENDED ENCL ENCLOSURE T.C. TOP OF CU•RP EQ. EQUAL TEL TELEPHONE EQPT. EQUIPMENT T&G TONGUE AND GROOVE E.W.C. ELECTRIC WATER COOLER T.G. TEMPERED GLASS EXST. EXISTING T.G./SP. TEMPERED SPANDREL GLASS EXPO. EXPOSED T.I.G. TEMPERED INSULATING GLASS EXP. EXPANSION THK. THICK EXT. EXTERIOR T.O. TOP OF FABR. FABRICATOR/ FABRICATED T.P. TOP OF PAVEMENT F.C. FURRING CHANNEL TS TUBE STEEL F.D. FLOOR DRAIN TV TELEVISION FDN. FOUNDATION T.W. TOP OF WALL F.E. FIRE EXTINGUISHER TYP. TYPICAL F.E.C. FIRE EXTINGUISHER CABINET FIN. FINISH UNF. UNFINISHED FIXr. FIXTURE U.G. UNDERGROUND FL. FLOOR U.O.N. UNLESS OTHERWISE NOTED FLASH, FLASHING UR. URINAL FLUOR. FLUORESCENT VCT VINYL COMPOSITION TILE F.O.C. FACE OF CONCRETE VERT. VERTICAL F.O.F. FACE OF FINISH VEST. VESTIBULE F.O.M. FACE OF MASONRY W. WEST F.03. FACE OF STUDS W/ WITH FRMG. FRAMING WD WOOD FR. TR. FIRE RETARDANT TREATED W/o WITHOUT FT. FOOT OR FEET WP WATERPROOF FTG. FOOTING WSCT. WAINSCOT FURR. FURRING WT. WEIGHT GA. GALVANIZED GL GLASS O COLUMN LINE GR. GRADE GYP. GYPSUM GYP BD. GYPSUM WALLBOARD X DETAIL/DWG. H.B. HOSE BIBB A1.1 H.C. HOLLOW CORE H.D. HEAVY DUTY HDWD HARDWOOD X ELEVATION/DWG. HDWE HARDWARE A4.1 BLDG. SECTION/DWG. H.M. HOLLOW METAL HORIZ. HORIZONTAL HR. HOUR X WALL SECTION/DWG. A5.1 DETAIL/DWG. HOT. HEIGHT HSS HOLLOW STEEL SECTION +U'-U" I.D. INSIDE DIMENSION ELEVATION FIN FL I.G. INSULATED, GLASS INSUL. INSULATION R VB1 FINISH INT. JAN. INTERIOR JANITOR F-X STOREFRONT TYPE JT. JOINT Px PARTITION TYPE KIT. KITCHEN L. LENGTH RETAIL ROOM & NUMBER LAM. LAMINATE XXX LAV. LAVATORY XX NUMBER LT.LIGHT © FE FIRE EXTINGUISHER MAX.DOOR MA MAXIMUM (XXXXX) REFER TO PROJECT MANUAL MECH. MECHANICAL SECTION NOTED PROJECT TEAM LANDLORD: RAMCO. GERSHENSON, INC 27600' NORTHWESTERN HWY, SUITE 200 SOUTHFIELD, MICHIGAN 48034 SOUTH MIAMI, FLORIDA 33143-5161 TENANT (OWNER IN FEE) PETCO Animal Supplies Inc. 9125 Relico Road San Diego, CA 92121 (858) 677-3007 Contact: CYNDI PRUZINSKY, PROJECT MANAGER ARCHITECT (TENANT IMPROVEMENT) SBLM ARCHITECTS 151 WEST 26TH STREET NEW YORK NY 10001 (305) 412-9187 Contact: MAURICIO RODRIGUEZ, Project Manager MECHANICAL f PLUMBING ELECTRICAL ENGINEER (TENANT IMPROVEMENT): HENDERSON ENGINEERS 8325 LENEXA DRIVE, SUITE 400 LENEXA KS 66214 (913) 307-5300 Contact: RANDY NELSON, Project Manager 2001 FLORIDA STATE BUILDING CODE ® Group: * Building Shell Type ;of Construction: IV © Allowable areas (with -Fully Sprinklered System): Allowable Building Area: Actual Building Area: M UA M 12, 828 SF ® Fire Separation Assembly Between Group M Tenants, with exception for Fully Sprinklered System: 1 HOUR ® Occupant Load :[Gross] M (Retail) 13, 614 S.F. 30 S.F./P.P. = 454 PERSONS M (Stock) 674 S,F. 300 S,F./P.P. = 2 PERSONS M (Grooming) 724 S.F. 30 S.F./P.P. = 24 PERSONS 77 r, Occupant Load = 480 PERSONS 95'1Vv43ttts4 3ti3:P iW; k sPRfPXIS ssW PET CODE DATA ® Egress Width: Required Provided M (Retail) 454 X 0.2 in. = 90.8 in. M (Stock) 2 X 0.2 in. = 0.4 in. M (Grooming) 24 X 0.2 in. = 4.8 in. 96 IN. 147" ® Number of Exits: Required Provided Group M (RETAIL) 2 2 Group M (STOCK) 1 1 Group M (GROOMING) 1 1 o ACCESSIBLE MEANS OF EGRESS REQUIRED: 2 PROVIDED: 2 L.JmJ IIIVV ILIYn1V1 VLIYII JIIYV �YnLLJ IV REMAIN SITE: KEY PLAN `3r� t�A i I VICINITY MAP a TENANT IMPROVEMENT F O R A NEW PETCO STORE A RD [ "SANFORD FLORIDA" tgl TOWNE CENTER BLVD & W.P. BALL BLVD SEMINOLE COUNTY u J fy 1 SANFORD, FLORIDA Qq CURRENT ISSUE DRAWINGS \`-� SHEET DRAWING TITLE CURR�T ISSUE DATE ISSUED 2001 FLORIDA STATE PLUMBING CODE: AO.1 Code Data, Project Data ADDENDUM #2 10/21/04 AU,L PETCO Vendor / Contractor Furnished Items PERMI'' 8/13/04 @)MINIMUM PLUMBING FIXTURES : A1.1 SITE DETAILS PERMIT 8113104 MERCANTILE 15, 012 S.F. TOTAL OCCUPANT LOAD = 480 PERSONS A"l,> DFemnolition Plan PERMIT 8/13/04 ® WATER CLOSETS A1.3 Building Shell Verification Plan (Exhibit B) PERMIT 80-3/04 1 EA. SEX PER 500 PERSONS Male Female A2.1 Floor Plan, Floor Finish, and Partition Notes ADDENDUM #2 10/21/04 REQUIRED 1 1 A2,2 Store Fixture Plan ADDENDUM #2 10/21/04 PROVIDED 1 1 A2.3 Reflected Ceiling Plan ADDENDUM #2 10/21/04 ® Lavatories I-N _r Roof Plan PERMIT 8/13/0'r 1 EA, SEX PER 750 PERSONS Male Female A2.5 Floor Finish Layout Plan ADDENDUM #2 10/21/04 REQUIRED 1 1 A3.1 Door Finish Schedules, Door & Storefront Types ADDENDUM #2 10/21/04 PROVIDED 1 1 A4•1 Exterior Elevation PERMIT 8/1:.3/04 o Drinking Fountain A:,,1 Partial Exterior Elevation, Interior. Wall Sections PERMIT 8/13/04 1 PER 1000 PERSONS Fixtures A5,2 Exterior Wall Sections PERMIT 8/1 Jr REQUIRED 1 AU.'1 Exte; for Detaiis PERMIT 8/1 J - PROVIDED 2 A7.1 Large Scale Plans ADDENDUM #2 10/21/04 ® SERVICE SINK REQUIRED A8.1 Interior Details ADDENDUM #2 10/21/04 1 PROVIDED 1 Ao.2 Interior Details PERMH 8/13/04. j A9,1 Interior Elevations PERMIT 8/13/04 A9.2 Interior Elevations PERMIT 8 '13/04 I PPv1i 1.') Plumbing / Mechanical / Electrical General Information ADDENDUM #1 8/19/04 P1.1 Plumbing General Information & Schedules r-%f,, Ufv1 /,�1 8/19/04 GENERAL NOTES REGARDING THIS PROJECT: P2.1 Plumbing Plan ADDENDUM #2 10/21/04 1. Refer to Drawing A2.2 for retail store fixture layout P3.1 Plumbing Large Scale Plans & Details ADDENDUM #2 10/21/04 2, Egress widths shown on "Code Data' diagram are P3.2 Plumbing Large Scale Plans & Details ADDENDUM #2 10/21/04 for automatic sliding entrance doors with breakout ' , 'f PlumbingRiser Diagrams &Detaiis ADDENDUM #1 8/19/04 doors/ panels. / P4.2 Plumbing Riser Diagrams & Details ADDENDUM #2 10/21/04 3. EXISTING MERCANTILE USE BUILDING. j IIA Mechanical General Information & Schedules ADDENDUM #1 8/19/04 M2.1 Mechanical Plan ADDENDUM #2 10/21/04 I 4, All Wood and Plywood Blocking used in Tenant M3.1 Mechanical Large Scale Plans & Details ADDENDUM #2 10/21/04 Space Partitions shall be fire retardant treated. ivi:3,2 Mechanical Details ADDENDUM #1 8/19/U4 - I STORE FIXTURE DATA REGARDING THIS PROJECT: Fire Suppression System General Information & Details PE RMi f 8/13/04 1. The highest store fixture for merchandise E1.1 Electrical General Information & Schedules PERM1 r F3/1;3/f)4 (racking) for this project is no more than 10 feet E1.2A Panel Board Schedules ADDENDUM #2 10/21/04 height to the top of store fixture. E1.213 Panel Board Schedules ADDENDUM #2 10/21 /04 2. The highest that merchandise will be stored in g E"1.3 Elr�ctrical Single Line Diagram and Details nr's rDDENDUM #1 8/19/04 l retail or receiving/stock areas is less than 12 feet height to the top of merchandise. E2.1 Electrical Lighting Plan ADDENDUM #2 10/21/04 I E2.1A Electrical Lighting Plan ADDENDUM #2 10/21/04 E2.2 Electrical Power Plan ADDENDUM #2 10/21/04 E2.3 Sound and Communication System ADDENDUM #2 10/21/04 E2,4 Security System Plan ADDENDUM #2 10/21/04 E2.5 Energy Management System Plan ADDENDUM #2 10/21/04 E3.1 Electrical Large Scale Plans, Details ADDENDUM #,2 10/21/04 E3.2 Electrical Large Scale Plans, Details ADDENDUM #2 10/21/04 i:..M131.it Energy Management System Information & Details PERMIT 8/13/04 _O p w ra -L O N cU q L0 CY m rN- E O 0 CV -0 '- (D W ? m Ln W (ll cv z I �, Architect: James Cohen V License 9: 0015903 m �r )� m V ®LL06 ZU) 0 0 �LIJ ® Cfll-❑ O-� z W 7)o CEO.. QI-O_J U z U L-. W W wW O woOa-U) zz� w 2z W l­_ cn 0 a®mil z o umiwmil � o �0rm'IYU 'Wi ° d =W 0 DISTRIBUTION: DATE: PERMIT 08/13/04 0 ADDENDUM #1 08/19/04 0 ADDENDUM #2 10/21/04 SBLM JOB# PETCO P.M. JOB # 04075 00000 DRAWN: CHECKED: MR/DB MR/SS DRAWING 'fl rLE: CODE DATA PROJECT DATA AO. 1 i i� cify OF SMIIF0 D P1 * 7/8 x 20 GA. Met F.C. framing 16 o.c. secure adj. wall substrate P2A Same as partition Type P2, P with exception of addition of: P / P3C * Some as Partition Type P3, w exception of addition of: / P / A ❑ Same as Partition T e P6, w addition of: / * 3-1/2" Sound Atten. Batt Insul. to 12" abv. highest adj. CIg. Hgt. FP Sarne as Adj. Partition Type P7 w/ Ion of: Z *Partition Framing Hgt. 9'-0" min., brace to ucture on concealed sides) * Partition Framing Hgt. to 1" from underside of roof deck. 6" x 20 GA. Met. Framing 16" o.c. (R-11) * 3-1/2" (R-11) Sound��n. Insul. to underside of roof deck abv. * 5/8" Gyp. Bd. one side (5/8" G d. if sched. on Fin. Sched) * Cyp. Bd. Fin. to 1" from underside of roof deck. * 3-1/2" (R-11) Sound Atten. Batt Insul. to 12" abv. highest adj. CIg. Hgt. ❑ * Gyp. Bd. Fin. to 8'-6" h side g P6B Some as Partition Type P6, w/ addition of: * 6% 20 GA Met. Framing 16" O.C. P9 2 HR. Fire Ra A ly (U.L. Design No. U419) � » W * Total Partition Thk. 1 face of adj. wall surface (non-firerated) P2B Some as partition Type P2, " with exception of: " * 16" g * 3-5/8' 20 GA. Met. Framing 1 o.c. rn * 6 x 20 GA Met. Framing 16 O.C. P4 3-5 8" x 20 GA Met. Framing o.c. / 9 � ,� * 3-1/2" (R-11) Sound Atten. Batt Insul. to 12" abv. highest adj. Gig. Hgt. Partition ming Hgt. to underside oof deck abv. w/ Fire w P1A Same as partition ,with exception of: *Partition Framing Hgt. 13 -0 min., brace to structure on concealed side s () Asse -tested Deflectio nn see 09260) H * bd. fin. to rom underside of roof deck. gyp- P2C ❑ Same as partition Type P2, P � with exception of addition of: P / * 5 8" G Bd. both sides 5 8" M R. G Bd. if sched. on Fin. Sched. / YP• (/ YP• ) P7 ❑ * " 3-5 8 x 20 GA. Met. Framin 16 o.c. / g, " �� * ayers 5/8 Typ d. both sides (5/8 Type-X/M.R. Gyp. Bd. z *concealed blocking where noted * Framingad to wall surface 1• w 1 4" nom. clears ace a / / P (gap) * Gyp. Bd. Fin. to 6" min. abv. CIg. Hgt. (see Fin. Sched) both sides of *Partition Framing Hgt. to 8 -0 g 9 ' if Fin. o Sam s partition Type P1, with addition of: * Exp. Met Security Mesh to 8'-0" nom. hgt. partition * 5/8" Gyp. Bd. both sides (Y2'� Cement Board where sched. on Fin. Sched.) sched. on c * Gyp. Bd. i Hgt. on both sides of partition. P1 B * xp. Met. Security Mesh ( see 05500) to 8'-0" nom. hgt. Total Partition Thk. 4-7/8" (non-firerated) * G Bd. Fin. to 8 -0 YP Firesafing ealant at top and Fire Sealant at base of partition Q * Total Partition Thk. 1-5 8" from face of ad'. wall surface non-firerated / 1 ( ) P3 * 3-5/8 x 20 GA. Met. Framing 16 o.c. P5 * " 3-5/8 x 20 GA. Met. Framing 16 o.c. * L-bead Gyp. Bd. edges adj. to aluminum storefront and dissimilar * " Total .Fire Rated Thk. 6-1/8 (or 8-1/2 ) w ❑ P1C *patch and repair existing wall finish * Partition Framing Hgt. to side(s) 12" abv. highest adj. CIg. Hgt., brace to structure * Partition Framing Hgt. to underside of roof deck abv. w/ Deflection Runner materials „ *Total Partition Thk. 4-7/8 (non-firerated me as Adj. Partition Type P8 w/ addition of: Y on concealed * 5/8 Gyp. Bd, both sides (A Cement Board where sched. on Fin. Sched) * * 5/8" Gyp. Bd. both sides (5/8 M.R. Gyp. Bd. if sched. on Fin. Sched) G Bd Fin to Full H t both sides of artition 1 HR Fire Rated Assembly (U L Desi o U419) P9 * R-11 2 3-1" Sound Atten. Batt. Insul. to underside of roof deck abv. / ( ) 0 P2 * 2-1 /2" x 20 GA. Met. - Framing 16" o.c. adj. to wall substrate w/ 3/8" *Gyp. Bd. Fin. to 6" min. hgt. above adj. CIg. Hgt. both sides of partition * g P P8 * " " nominal clear s a Total Partition Thk. 4-7/8" (non-firerated) 3-5/8 (or 6) x 20 G ®t. ming 16 o.c. ace w p (gap) * L-bead Gyp. Bd. edges adj. to aluminum storefront and dissimilar materials * * Partition Framing erside of roof deck abv. w/ Fire T_ * Partition Framing Hgt. to 12 abv. highest adj. CIg. Hgt., brace to structure * Total Partition Thk. 4-7/8 (non-firerated) 3-5/8" x 20 GA. Met. Framing 16" o.c. on concealed side(s) P6 * Partition Framing Hgt. to underside of roof deck abv. w/ Deflection Runner Assembly-teste fl Runner (see 09260) C * 5/8" Type d. both sides (5/8" Type-X/M.R. Gyp. Bd. if sched. on z * 5/8" Gyp. Bd. one side (5/8" M.R. Gyp. Bd. or 1/2" Cement Board, where Some as Partition Type P3, w/ exception of: * 5/8 Gyp. Bd. both sides (5/8" M.R. Gyp. Bd. if sched. on Fin. Sched.)l o P3A * " * G Bd. Full Hgt. one side, to 6" min. abv. CI Hgt. see Fin. Sched. on Fin. Sched) sched. on Fin. Sched.) 6 x 20 GA Met. Framing 16 O.C. yP• g g- g ( ) *Gyp. in. to Full Hgt. on both sides of partition. � * Gyp. Bd. Fin. to 6" min. hgt. above adj. clg. hgt. other side PARTITION TYPES * Total Partition Thk. 3-1/2" from face of adj. wall surface (non-firerated) P3B Same as Partition Type P3, w/ addition of: * L-bead Gyp. Bd. edges adj. to aluminum storefront and dissimilar materials * F' afing/Fire Sealant at top and Fire Sealant at base of partition G_ ❑ * 3-1/2" R-11 Sound Atten. Batt Insul. to 12" abv, highest ad'. CI Hgt. * Total 1 HR. Fire Rated Thk. 4-7/8" (or 7-1 /4") / ( ) 9 1 9• 9 Total Partition Thk. 4-7/8 (non-firerated) REF.: 0 I- cy IL G T E p C BT Z W z 0 U2 W A4.1 LU ±17'-4" ±41'-1 1/2" ±35'-O" ±35'-O" ±38'4' ±5'-0 3/4' yj 1....... — — — — W_ f-Y Q W / CLOSET P2 I t o I40C Q I 0 I r - P2A I P1 C P1 C P6 P2 z Q I P2B IP6A I 10 P3 CAGE ROOM P2 I LL WOMEN S 108 I 18 I I ''';;:;1 P3A 105 µ 0 F_ I P1CCORRIDOR 2 1 I I I I P6 9 P2B z I i 14 11 g P3 I I SLOPED CONC. TUB RO F FLOOR & FLOOR X w 08 I PTD. AREA B I DRAINS/REF. A7.1 106 P3A w> o I P2 I I P3 E � MEN'S 109 I IP6A '� I ill I 12 Q J --- - - --- "1 �` `- _..- __�'-\ I GROOMING SALON T I- ISO. ROOM I P2 I �'��'�� �� �'� I P6 107 P3 P2 -- — _! - , — o a 117 I i P6 FOR FLOOR FINISH RETAIL \ - Q I I 0 ❑ I I I 102 LAYOUT �,� I GROOMING z I I I P5 P6 RECEPTION I I z o I P3 P3 . 1 F-0 r 104 oQ I I _ — — — — _ _- — — I� — -- -- CN, w co II H 4 49 0 1A] 50 WORK P2 ROOM lFl-81 IP6A P3 I JANITOR'S CLOSET1 20 120 I 15 I I CORRIDOR 1 I P2 P3 111 BREAK RM. I P2 6A �i P6B I. -J CLOSET I P7 I 1 110 21 I J \ TYP. GYP. BD. — — CONTROL JT. 04 A5,1 I A8,2 A6.1 Pic PRE SALES P5 116 1 17 P1C I N Pic PTD. PLYWOOD TO 4'-0" HEIGHT ON GYP. BD. 16 P1C P1C c�fi-..._ 4 P5 9 II 4 I I I P6 P4 ® I— GROOMING . 3 A3.1 ........................... 1 ¢ I LOBBY/WAITI G _0 9'- 8" L¢ I 103 P5 P6 II y FINISH SCHEDULE T ORIENTATION FOR \ N I \ w INTERIOR WALL FINISHES REF A3.1 05 I I U 20 AQUARIUM AREA FALSE AS.1 PROVIDE 42" STAINLESS 82 I COLUMN (2) 1 STEEL COLUMN COVERS 6� REFER TO DETAIL 20/A8.2 01 I 2 �1 w I I I `- \ FOR ADDITIONAL 1= . �� (10300) FOR ALL I INFORMATION ON I A7'1 FREESTANDING COLUMNS AQUARIUM AREA I ... I , VESTIBULE IN RETAIL AREA-TYP. 115I c_n REFER TO DET 12/A8.2 P6 1 11 x LU .............. _._.,.............................. ...........I... \\ � I FLOOR PLAN NOTES GENERAL: J 1 VE�IFY MEASUREMENTS WITH CORRESPONDING -`- FT-1 gONSTRUCTED OR EXISTING CONDITIONS PRIOR TO PROCEEDING WITH THE WORK, AND NOTIFY THE ARCHITECT IMMEDIATELY OF SIGNIFICANT I I JJ DISCREPANCIES USING THE CONTRACTOR REQUEST FOR INFORMATION" FORM (01200) AND SUPPLEMENTA - CONTRA TOR DETAILS AS REQUIRED 2, R5JAf AREAL��ft1V K Y: PTD. AREA B / PTD. A A WALL PTD. COLOR � (09900) W/VINYL BASE 06 O1 A7,1 IRD ROO i16-11 1/2" A5.1 P1C PTD. AREA B WALL PAINTED COLOR GRAY 1 1 J J (09900) PRIMER ONLY BELOW- 6'-0", AND VINYL BASE ON i P5 \I J I WALLS BEHIND STORE I ¢ FIXTURES \ 1 _04 ,' 13 3. SEE A19 / A8.2 FOR FTP C.J. 0 GYP. NOTE: I I' 2'X4 CONCEALED OR = � tr P6B PROVIDE THROUGHOUT AT INTERVAL MAX 30. SURFACE MOUNTED ¢ P2 I BLOCKING V-0" HOT. TO I I 113 OFFICE P1C CENTER AROUND RETAIL T, P1C 1­_I P6A P2 �. ---- ±167'-5 1/2" I — — — — — — II. FLOOR PLAN REF.: SOURCE: `1 N o O N N co 0 o 0 T O N b SOURCE: 16 N.T.S. E 47 48 01 1/8" = 1'-0" 0 0 C) LO LD U U) ? a) Co E V CV Z CV Lf) C) r- a Zl)) W l r2 CV ? U) F---- coCfD Archilecl: Jar nes Cohen License It: 0015903 m J J � � m 0 a. ILL. 06 Z C/) 00 �W 0m�o O� �O�zo i DO- �C [- o J �� U) zuLL. Lii u W O woC a-u) �z- LL z0 OW< 1-- (n (n G 0 II o 'Gal ,� s C1 2 OC = o �W 9L�z �u) DISTRIBUTION. DATE: PERMIT 08/13/04 ADDENDUM #2 10/21/04 SBLM JOBA PETCO P.M. JOB 11 04075 00000 DRAWN: CHECKED: MR/DB MR/SS DRAWING TITLE: FLOOR PLAN AND PARTITION NOTES A2.1 w J W Y 0 w T I— z_ 0 C a 0 I — Ix 0 IY a z 0 z w 0 w vi I— w_ J U W Z fya o W U cl� U ❑ cn W } Z z 0 Fa 0 ❑ �— ZU 0 w U I- 0T z U Q X W w= H RLL � w0 > Z T Ta N0 �r( a UJ T 0 Q • 6 0 0 r (C) G) } 0) N U) v Z CV � o Q i T) CV U) i n CV Ca Lo i - X 2 tq L L ArchilecL- Jarnes Cohen License It: 0015903 J n • J < Z z u) ® ❑ W Q m Q O� zw o (n Z U H W W W OWO� 0- CIS � Z z O W Ow< Cl �— U) Ua '4 N N 0 101FITHI, FOR < tr C)0 r 0� Oj WW �n w w DISTRIBUTION. DATE: PERMIT 08/13/04 0 ADDENDUM #2 10121/04 SBLM JOBY PETCO P.M. JOSS )l 04075 00000 DRAWN: CHECKED: MR1DB MR/SS DRAWING TITLE: STORE FIXTURE PLAN A2.2 } A z 0 w u I- z 0 w J Q w 0 Y If 0 w z 0 z a 0 a 0 0 z (14�0 0 U z w 2 0 W (Q I- W_ U Q Ia lw 0 U ❑ (J) Q � zz 0Q LL z Ow U I- (� T Z U p �Q X w W T a� W Q z Q} J T IL �? o 0G I- J U J Q U) Z 0 OZ< s 148 50 — REFLECTED CEILING PLAN NOTES, GENERAL: 3. SYMBOL KEY: 1. VERIFY MEASUREMENTS WITH CORRESPONDING CONSTRUCTED OR EXISTING CONDITIONS PRIOR TO PROCEEDING WITH THE WORK, AND NOTIFY THE ARCHITECT IMMEDIATELY OF SIGNIFICANT DISCREPANCIES USING THE "CONTRACTOR REQUEST FOR INFORMATION" FORM (01200) AND SUPPLEMENTARY CONTRACTOR DETAILS AS REQUIRED. 2. REFER TO SHEET A0.2 AND PROJECT MANUAL SECTION 10300 FOR DESCRIPTION OF THE DIVISION OF RESPONSIBILITIES BETWEEN PETCO VENDORS AND CONTRACTORS. � A ACT- ---.... _...._............... _._.... B T Z T CG T D _ I I I "P NOTE: ALL EXPOSED CONSTRUCTION AREAS TO BE PAINTED PER SCHEDULE. PREPARE ALL EXIST. SURFACES AS REQUIRED LIGHT FIXTURE IN SUSPENDED ACOUSTIC TILE CEILING / REF. ELEC. SURFACE MOUNTED / UNIISTRUT MOUNTED LT. FIXTURE / REF. ELEC. DIFFUSER / REF. MECH. CONCENTRIC DIFFUSER / REF. MECH. CEILING TILE TYPE/REF. All, 09510 ACT CEILING 40 131 SALON80„ FILING EL 12`-0" 4z CEILING 12'-0" CEILING CONSTRUCTION: 5 8' ). ON 7/8" x 20 GA F.C. 12" O.C., ON _AR 2 1 /2" x 20 GA. MET. FRAMING O.C., SUSP_ FROM BAR JOISTS ABO 4`4 ING %ITING .11 145 46 50 REFLECTED CEILING PLAN 1 01 1 REF.:, SOURCE: 1/8" = 1'-0" CD (, O S N C) CS> co N +? ry CV U 2 c- S N CO CL r N Q CV 10 m n u w v) - z I- U- E 1 Architect: Jarnes Cohere License It: 0015903 DISTRIBUTION: DATE: PERMIT 08/13/04 ADDENDUM #2 10/21/04 SBLM JOEW PETCO P.M. JOB It 04075 00000 DRAWN: CIIECKED: MR/DB MwSS DRAWING TrrLE: REFLECTED CEILING PLAN A2.3 (6 0 L ❑ W U) W T Z W J H W Y 0 W T c� Z 0 0 C n U N� 0 a (L U) Z 0 U) z W 0 I— W � Q 0� ,i OW U IY ❑ ai Uz Z Z 0LL �0 Z U oF- (9_ z� U)Q 5C W WT U- wLL - > 0 Z Q} J T IL w 0 ry a ~ J U Q T 0Z U Q • HOW TO LAYOUT AN ELLIPSE With "A" as the center and half the minor axis AJ as a radius, draw the circle "BJ". With "A" as the center and half the major ~� axis "AC" as a radius, draw the circle -r `"v Cw . u Draw a number of radii at randum, as "Akr" "Ares" "Ant", "Apu" "Aqv" I Drop verticals from "r" to �` ' 1 " �9 J intersect a horizontal from its corresponding point "k" at "D". / In a similar manner find points ..; „E" "F„ »G" and ,>H„ s A, ` ; .....1 F J .. / I Fi<.. y .. :................. ellipse thru the �--- Draw the el points thus found as ;'IE /m ray f ....... .... ..:-::.. k ................ ....... ... y.............. - ....... .......... C I ............................................. ...... .............: ........... HOW TO LAYOUT AN ELLIPSE 20 REF.: A2.1 SOURCE: NO SCALE --!-17'-4" . I 40( ° vsF WOMEN'S 108 CORRIDOR 2 119 VCT-2 0 MEN'S l 109 l o �VSF ICJ ISO. ROOM C.S. 117 WORK ROOM T JANITOR'S CLOSET C.S. �- 11 120 C.S. _ VCT-2 CORRIDOR 1 I i BREAK RM.FL € _ J I 112 VCT-2 CLOSET Di 110 -J C. S. r- D48 0 i 49 - FI EI V' O FI _ O v I PRE SALES 116 C.S. (a r> ±AV-1 1/2" 1 t35'-0" VCT— 2 I 47'-6" :L35'-0` RETAIL 102 � I I VCT-1 / f'-2" 5'-5 1/2" / \ 2'-1 1 1/2 5 -5 1/2' 5 -3" 4 -7 1/2" AQUARIUM 49'-8" -± 167'-5 1 /2" I W-5 1 /2" RO I II` ±5'-0 3/4" CLOSET 114 C.S. 40 CAGE ROOM I J 105 EPDXY ` I � TUB ROOM III N , 106 N v GROOMING SALON ~ EPP 107 VCT-2 I r CO , cV — 42 — o --T — ... -J - GROOMING - RECEPTION 104 ( - GROOMING LOBBY/WAITING - 103 , III13'-10 1/2" I fi I fC — -- Q o VCT-1 MAT � z I N Cv I� j VESTIBULE / 101 � U) � o / \ 0 `r 45, 16'-11/2" , 1 �� i o co CA ! CV o VCT-2 — ....` -- Cl) - - ------------- - cV N I L — J VCT-2 OFFICE I �I 113 FLOOR FINISH LAYOUT PLAN REF.: A2.2 SOURCE: 50 01 CJ (D r �J N c�U LO 0) U r O> N C\, v E L Z C\1 L) v N Q c clC\ 1 N X m if) N cU QJ LL CfD �1 J QU CD 2Z LL Z U) 0- QW 0 ml}--o ®ZFY —J Z W D00 Ua- can z°LL 1 W U WD 0 woo U)�-- z z LL [� O L/r.I.'.�I /<rn i o0 O J U "11uuw,u Ad z W W 41W9N Z: DISTRIBUTION. DATE. PERMIT 08/13/04 ADDENDUM t>t2 10/21/04 SBLM JOBA PETCO P.M. JOB Y 04075 00000 DRAWN: CHECKED: MR/DB MR/SS DRAWING TITLE: FLOOR FINISH LAYOUT PLAN A2.5 ui z 0 W U) W T I- z W _I 4 W ❑ Y fy uw T I- c z 0 0 IL 0 U a W z 0 z W 0 IW- w WQ Cr a 0 W U � Q° z ZQ 0� �0 z U 0 Lu zT r( Q W W LILLL wF >U z T_ n CL U)0 i n 0 J 0 z ROOMS WALL FINISHES ------------- A2.1 ROOM WALL CEILING MATERIAL/ TEXTURED/ WALL MATERIAL/PAINT COLOR: SEE SYMBOL ON A2.1 FOR ORIENTATION MARK NAME FLOOR MATERIAL (REF) BASE PAINT COLOR CLG. HT. UNTEXTURED 1 2 3 4 REMARKS 101 VESTIBULE FLOOR MAT (10300) - SUSP ACT-1 12'-0" - - - - - ................................................................................................................................... __........._..............-------- .._...................._....-.-----...................................----........................... ..............................--------...._............................... ... ............................................................................................ OPEN STRUCTURE/ 102 RETAIL VCT (09650) VB PTD WHITE - SEE NOTE 8 GYP -GRAY GYP -GRAY GYP -GRAY GYP -GRAY REF. A2.1 WALL FINISH KEY GROOMING LOBBY / VCT (09650) VB - SEE NOTE 8 GYP -GRAY GYP -GRAY GYP -GRAY GYP -GRAY REF. A2.1 WALL FINISH KEY 103 PTD WHITE - .............................. __.._ __..__....... WAITING 104 GROOMING RECEPTION VCT (09650) VB SUSP AC r-1 '12'-0" SEE NOTE 8 GYP -GRAY GYP -GRAY GYP -GRAY GYP -GRAY [REF. A2.1 WALL FINISH KEY 105 CAGE ROOM EPDXY (09670) 6" EPDXY SUSP ACT -2 10'-0" - FRP/GYP-GRAY FRP/GYP-GRAY FRP/GYP-GRAY FRP/GYP-GRAY FRP FULL HGT. ._..______..._._-------------------------------------..... _._._.....�...._.............. ..------............................_..._....-.--.---------......................-........................................................................................... _ . 106 TUB ROOM EPDXY (09670) 6" EPDXY M.R. GYP -WHITE 8'-0" SEE NOTE '10 C.T./ CEM. BD. C.T./ CEM. BD. C.T./ CEM. BD. C.T./ CEM. BD. 107 GROOMING ROOM VCT (�9650) CB SUSP ACT-1 8'-01, SEE NOTE 8� M.R. GYP./C.T. M.R. GYP./C.T. M.R. GYP./C.T. M.R. GYP./C.T. C.T. 3'-5 "1/4" HGT., PAINTED GRAY ABV. GRAY .ABV: .GRAY ABV..:.__ GRAY ABV. GRAY ABV. -----............................ _.... __.__---�-------.......... .................. ............ ....__'-----.._.................................................................................................................................................................................................................................................................................. _ ._............1....._ - ....._................... _ -........................._............ ....... ONE WAY GLASS OR REFLECTIVE 108 WOMENS RESTROOM VSF (09660) 6" VSB SUSP ACT-2 8'-0" SEE NOTE 8 FRP WMIITE� (P- FRP WM+ RE YP- FRP WNITE� (P- FRP WMIiRE YP- I FRP 4'-0" HGT.; "WOMEN" SIGN (10300) -j PRIVACY FILM (08800) ON RETAIL SIDE (OFFICE ONLY) 9 FRP/M.R.GYP- FRP/M.R.GYP- FRP/M.R.GYP- FRP/M.R.GYP- ���~�\•�r��� SIM. 109 MENS RESTROOM VSF (09660) 6" VSB SUSP AC r-2 8'-0' SEE NOTE 8 FRP 4'-0" HGT.; ..MEN" SIGN (10300) _ Ag 1 WHI rE WHI fE WHITE WHITE INTERIOR 4 TYP. INTER 0 .....__....._......................._....____....................._.....__...._....................................._..........---.................... STOREFRONT SECTION -----....__..._-----------------•---------------___-----•------------.........._._....................................................-•--•--................................................................................................................. 110 CLOSET COh1C. SEALER (09910) - OPEN STRUCTURE - - GYP-UNPTD. GYP-UNPTD. GYP-UNPTD. GYP-UNPTD. _... .........fey... __..._.. . .............._ ..—..__ ,n 111 CORRIDOR 1 VCT (09650) VB SUSP ACT-1 8 -0 SEE NOTE 8 GYP -WHITE GYP - VVH ITE GYP -WHITE GYP -WHITE FRP 4'-0 HGT. AT EWC i _� T. CO) I T. G. T.G. y _ _ ---......._............................ __._._................................_._ 112 BREAK ROOM VCT (09650) VB SUSP ACT-1 _ 8'-0" SEE NOTE 8 GYP -WHITE GYP -WHITE GYP -WHITE GYP -WHITE ::, ... : - - - -WHIT IT GYP _ rP WHIT G rP -WHITE 113 OFFICE VCT (09650) VB SUSP ACT -'I 8' 0" SEE NOTE 8 G (P WHI rE. �.;. __........................._. _ _ _ __...._......__......-------..._----..............---.........._..-----......_....................................................................................... ....................... ..._........... _ - .._........ ......................._...................................... ......... _ _. ------....................- _----------------- ............................- ------------............. ............................... - - 114 CLOSET CONC. SEALER (099"10) - OPEN STRUCTURE GYP-UNPTD. GYP-UNPTD. GYP-UNPTD. GYP-UNP D. — J / _ SEE NOTE 2, 3, 6, 7, 8 tr)' I r /J' OPEN STRUCTURE 9 n i — 7 � EPDXY 096 0 AQUARIUM AREA E 0 .; 115 AOU U ( ) PTD. WHITE_................................................................................................................... 116 PRE -SALES l CONC. SEALER (099"10) - OPEN STRUCTUO. WHITE RE/ PTD. WHITE PTD. WHITE PTD. WHITE PTD. WHITE PTD. PLYWD. TO 4'-0" HGT. ON GYP. BD. SF05 CLEAR ANODIZED SF06 CLEAR ANODIZED SF04 CLEAR ANODIZED 117 ISOLATION ROOM CONC. SEALER , (09910)1 6" VSB _ SUSP ACT-2 8'-0" SEE NOTE 8 I M.R. GYP./FRP M.R. GYP./FRP M.R. GYP./FRP M.R. GYP./FRP FRP FULL HGT. _ ............................... _ _ _ ___ _.._......__..__ ;_- 118 WORK ROOM CONC. SEALER (099.10) 6" VSB SUSP ACT-2 18'-0" SEE NOTE 8 M.R. GYP./FRP M.R. GYP./FRP M.R. GYP./FRP M.R. GYP./FRP FRP FULL HGT. 119 CORRIDOR 2 VCT (09650) VB SUSP ACT-1 8'-0" SEE NOTE 8 GYP -WHITE GYP -WHITE GYP -WHITE GYP -WHITE FRP 4'-0" HGT. AT EWC ( l _ MPER WALL BUMPER c.•.............................. ................ ...._.._.......................................... ........................ ....._........_.... __._--------_._._._.-._...................... ...... ................... ......... ............................ ........................................................ _................................................ 10300 ON l-3 4"TYP. INTERIOR t;a.1 SIM. � `P ( ) I^5.1. / 120 JANITOR CLOSET CONC. SEALER (099"10) VB M.R. GYP -WHITE II fE 8 -0 - M.R. G ( ./FRP M.R. GYP./FRP M.R. GYP./FRP M.R. GYP. FRP FRP FULL HGT. RETAIL SIDE SIM. Al STOREFRONT SECTION .-r- r- r, r-r-r_rr-r-r�, r r. r rr r r-rr r-e r..r.�, r-r-.--r-r-r•rrl--r-r-r-`-r-r-r-r-rr--rr-rr-r-r-r-i-r-r--l-•r-r-r-.-r-r-r-.--+="l-r�-i-r-•r^l-r-r-r-r-.-.-r�--r-r-r-rv�r-r-r-rr-r-r-.-r-r-i-r-r-r-r-r^r^r-r r,rr -- �� T rr rr- r,r - I - RIPn Rom KIT (1nmn1 - w•._ : (_J ! 1 _1 I - - I - -................................ .. ...r...r...c.r..r..:.c.,�- r..:�,.c...a.r..G:..�..r....^.t.:.r..:.`::..^...n.c r..•:.ns..n.r c...r .a..r...� a:..cs�. r..,.rr...r_.c.c...c...e:..c.r:.r_.c..e:.t. .r....t.-..e:..r...c..r.r ^.r:.c..r:.e...r..,c...c c...c...e.:.c...c....^...^.r..:..^...^.:.�:..r.,.r...r...r..i:.�'..r.:.�:......................... �^..�:. �.�:...r..�.c...e:.c...�:..e.;.c..� c...c...c..c.�:..^..^...c:.r..,.�::r......,r.,.c.,.r...c...n.c c...r_��.�:.r...^..,.^:..^...�:..c..c �.�.....<.:.i:.�:.�:.c..�:.c.:.^..,c.:.r.:.....c..c...c:.....,r...i:......r.c...c....�..nc..c.:.r...c.�.(:.��.r...�.,c..i:.�..�..,r..r..,r:..r..:c.:.r....r c.�• I T, G. T0".\ T. G. T, G. T, G. .._._........ - _ _ --- - - — _._._`.._._ GENERAL FINISH NOTES: 1. EXPOSED STRUCTURAL COLUMNS PAINTED GRAY/ PROVIDE STAINLESS STEEL COLUMN COVERING ('10300) TO 42" HGT./ REF. DET. 12/A8.2. I IAniI I„ Anr A. nnXA,rn nni r CLI AI I DC 'CI A-r DI A(`I/' 1 - •••%.•• ' -- L. /A1.juiir\IUIVI Nr\Em. r VYYCf\ rULL -)IIt\LL UL I Ln i ULn�a\ ONE WAY GLASS OR REFLECTIVE 3. EXPOSED FIRE SUPPRESSION PIPING, PLUMBING, MECHANICAL AND ELEC TRICAL EQUIPMENT SHALL BE PAINTED SUBJECT TO LIMITATIONS (09900). PRIVACY FILM (08800) ON 4. PROVIDE WALL CORNIER GUARDS (10300) AT ALL IN PARTITION OUTSIDE CORNERS, EXCEPT WHERE NOTED OTHERWISE/ REF A7.1. 10 i gc3,1 RETAIL SIDE 5. PROVIDE WALL BUMPERS (10300) AT INTERIOR PAR-rITIONS/ REF. A7.1. _ 6. EPDXY FLOOR FINIS_H_(OVERLAYMENT) & BASE/ REF. DET. 08/A8.2. 4 1 /2" �� 1 7. SEE • FLOOR PLAN (A2.5) FOR EPDXY FLOOR LAYOUT DIMENSIONS. FANODIZED 8. CONTRACTOR'S OP 1Ic�7J0 PROVIDE 'LIGHT ORANGE PEEL' TEXTURE, OR UNTEXTURED (SMOOTH FINISH). ALL WALLS AND SF02 CLEAR ANODIZED S 03 CLEAR ONE WAY GLASS EXPOSED WALL RETURNS (FOR EXAMPLE, AT STOREFRONT) SHALL BE EITHER 'ALL TEXTURED' OR 'ALL UNTEXTURED'. 9. PAINT COLOR GRAY. PROVIDE PAINT COLORS PER SECTION 09900. FINISH SCHEDULE 11 10. INSTALL 6 MIL (MIN.) POLY VAPOR BARRIER BEHIND CEMENT BOARD TILE BACKER AND SECURE TO METAL FRAMING. REF.: A2.1 SOURCE: 1/2"=V-0" LOCATE KEYSWITCH ON 1f} RETAIL SIDE LOCATE KF_YSWITCH ON DOOR FRAME ......... - R \ j RETAIL SIDE _ (INTERIOR D00 c� /R, 1 U UN I f pF.............................................................................................................................................................. UNIT) AN DOOR UNI HDWE FIRE ON V STIBULE............ _ - A2.1 SWING FINISHNSOM BY AUTOMATIC DOOR MFR SIDE (EXTERIOR T) MARK FROM/TO TYPE MATERIAL WIDTH HEIGHT THK. FROM/TO MATERIAL HEAD FINISH SET LABEL REF REMARKS -------------- -........ ---- - **1 101/EXTERIOR AU-2 ALUMINUM/GLASS LITES 14 -0 7'- 6 STD. MFR. PREFIN. AL UNIT STD. MFR. PREFIN. 1 08 r10 AUTO DR. UNIT W/ BREAKOUT w/ TRANSOM UNIT UNIT ----- ...... ....___ _..-_...................................__ .-... __.................................... ................................. .._......_---------... ....................... ............................... ..........._............;................................................__...................................................................................... T. r.G. r.G. T. G. T.G. 14'-0" 7'-6" DOOR SIGNS 2 102/101 AU-2 ALUMINUM/GLASS LITES UNI f UNI f STD, MFR. PREFIN. AL UNIT STD. MFR, PREFIN. 1 08410 AUTO DR. UNIT W/ BREAKOUT w/ TRANSOM 08 ('0300) 3 102/101 AU-1 ALUMINUM/GLASS GLASS LIrES UNIT UNIT STD. MFR. PREFIN. AL UNIT SDMFR. PREA 2 - r10 AUTO DR UN IT W/ BREAKOUT AKOUT w/ TRANSOM OM r T. G. i / T. I II / T. G. II T.\G. \ II \ \ I 4 101 /104 I AL-1 ALUMINUM/GLASS LITE 3'-0" 7'-0" STD. MFR. PREFIN. ALUMINUM "1-3/4 I MFR, HREFIN. T - U6TI u Vf f �)= I rlvv l rnlv�t� \T T. G. 5 104/103 AL-1 ALUMINUM/GLASS LITE 3'-0" 7'-0" STD, MFR. PREFIN. ALUMINUM 1-3/4" MFR. PREFIN. 4 - 08410 OFFSET PIVOT HINGES �: I � I 6 118/117 FL HOLLOW METAL 3'-0" 7'-0" 1-3/4" PTD. GRAY HOLLOW METAL 2" PTD. GRAY 9 - 08100 FIXED MET. LOUVER / I r 1 7 104/103 AL-1 - ALUMINUM/GLASS LITE - S —0 7 —0 STD. MFR. PREFIN. ALUMINUM 1-3/4 MFR. PREFIN. r 1 08 r 0 c F. PIVOT HINGES OFFSET PI 0 T T. G. I .. ........ ...................... ... ............. ............................................ ................ ............. - .. ...................._._.._.._.._........------.........................._..._..................................................................................................... / / I — ... -......... 8 .............. .. __._......... 119/109 .............................. _.._ F ... .____...-------.......... ................................................. HOLLOW METAL 3'-0" 7'-0" 1-3/4"' PTD. CRAY HOLLOW METAL 2" PTD. GRAY 9 - 08100 AU ­1 AU-2 9 119/108 AL-1 DOUBLE ACTING ALUM. 3'-0" 7'-0" 1-3/4" MFR. PREFIN. ALUMINUM 1-3/4" MFR. PREFIN. 7 - 08410 CENTER PIVOT HINGES W/ PUSH BAR BOTH SIDES J „ .....;...�........ ANODIZED CLEAR ANODIZED (INTERIOR INTERIOR UNIT W/ 72 BREAKOUT, CLEAR UNIT) W/ 44 1/4" BREAKOUT EXTERIOR UNIT W/ 72" BREAKOUT, FINISH/ COLOR TO 10 114/105 FL HOLLOW METAL/LOUVER 3'-0" 7'-0" 1-3/4" PTD. CRAY HOLLOW METAL 2 PTD. GRAY 11 - 08100 FIXED MET. LOUVER SEE A2.1, A7.1 FOR 0-SX MATCH EXTERIOR STOREFRONT - -1 UNIT 11 111/112 F HOLLOW METAL 3'-0" 7'-0" 1-3/4" PTD. CRAY HOLLOW METAL 2" PTD. GRAY 9 - 08100 HANDING 0F A U (CRITICAL) H.M. WELDED FRAME '12 104/106 AL -"I ALUMINUM/GLASS LITE 3'-0" 7'-0" STD. MFR. PREFIN. ALUMINUM 1-3/4" MFR. PREFIN. 4 - 08410 OFFSET PIVOT HINGES W/ NO STOPS ------- ---- -- ---- -- -- 13 102/113 F HOLLOW METAL 3'-0" 7'-0" 1-3/4" PTD. CRAY HOLLOW METAL 2" PTD. GRAY 9 - 08100 ..._-----------------....._.........._........-----._----------------------•--.._.................---..._._._.._.._---- ---- ................_......._._ _ � _ _... __... �} S fIC AL. DOOR HD. Ir VISION StON LITITES WE'"14 102/EXT EXISTING EXISTING TO REMAIN PTD. CRAY PTD. GRAY *13 REFIN/REPAINT COLOR TO MATCH NEW SCHEME VARIES / „ „ r r - V R rIX MET. LOUVER _ � » � - - - 15 102/EXT FL HOLLOW METAL 3)-0" 7'-0" 1-3/4 PTD. GRAY HOLLOW METAL 2 PTD. GRAY 9 08100 ED - 1 FIM HEAD \ - - - —_ .. - _._ -- _....._......._._........._...................... _ _..._._.__..._.. _ I WHERE \ / \ /' \ - _ /. I SS��U ITY // TAG 12"H. i 20 W 16 111 120 DA ELIASON DOOR - (2)3'-01, 8'-0" 1" MFR. PREFIN. HOLLOW METAL 21' PTD. GRAY 12 - 08300 HM WELDED FRAME w/ NO STOPS DOOR "" , , MET. LOUVER _ _ I _ _ _ _ _ - - REFINISH AS NECESSARY LIKE NEW \ / \ I / \ **17 116/EXT RD ROLLING DOOR - r-.............._.................................................................................................................................................................... I VIEWER `1 WHERE \ / 18 119/108 r - HOLLOW METAL 3'-0" 7'-0" 1-3/4" , P"rD. GRAY HOLLOW METAL 2" PTD. GRAY 9 - 08100 I SCHED. — �s� **19 116/EXT EXISTING EXISTING TO REMAIN PTD. GRAY PTD. GRAY *14 REFIN/REPAIhIT COLOR TO MATCH NEW SCHEME 1 / 0 \ EXIT ALARM, ......... .......................................................... .._.._._.m.__.................................................................. _ ._.._...._._ ._.------.._...._.._....... _._.......... ................................... _......._----- ............. -.................................................... FIRE/EXIT DEVICE` / \\/ j_ — —\\,/ 20 111/118 F HOLLOW METAL 3'-0" 7'-0" 1-3/4" PTD. GRAY HOLLOW METAL 21' PTD. GRAY 10 - 08100 WHERE SCHED. ``' RD F DA AL-1 FL 21 110/116 FL HOLLOW METAL/LOUVER 3'-0" 7'-0" 1-3/4" PTD. CRAY HOLLOW METAL 2" PTD. GRAY 11 - 08100 FIXED MET. LOUVER - _._._._ - _ ... - - _ ....._..................._.__ _............................_.._.....__............................................... ............... ............ ......_._mm. T.G.= 1 /4" TEMPERED GLASS GENERAL DOOR NOTES REPAIR/REMOVE/REPLACE EXIST HARDWARE AS REO'D TO MATCH SET INDICATED AT EXIST. DOOR 1. EXTERIOR H.M. DOOR & STOREFRONT TYPES 04 2. REFER TO FLOOR PLAN / LARGE SCALE P& FRAME PAINT LANS S FORLOR TO MALLFDOORA"LEFT/RI CENT BUILDING COLOR. DOOR /FRAME SCHEDULE 01 c REF.: SOURCE: 1/4"=1.0.1 3. INTERIOR DOOR FRAMES PAINTED SAME COLOR BOTH SIDES REF.: A2.1 SOURCE: 1/2"=1'-0" 0 T. C. i \ lyB //// n L C Architect: Jame Cohen License It: 0015903 m <C) n ._, Zu) no Qw Q Q�Q ®� Z w�EK C�®- <�°_j 0 v) z 0 IL i W W UJ❑ wD o U z°0 W OwQ 1- c) cn '�WImLU' U) I' Q Qmell�l m � 0 '�p�' [D dLiIllllll!III C QJ W ad w_ E IL R v)U) DISTRIBUTION: DATE: PERMIT 08/ 13104 ADDENDUM #2 10/21/04 SBLM JO811 PETCO P.M. JOB 1,< 00000 DRAWN: CHECKED: DRAWING TITLE: DOOR SCHEDULE FINISH SCHEDULE DOOR TYPES All uS C7 z 5 6 1/2" F.U.M. ❑ w 1n w G � o z w I� - Q \_ w Y Ly - Q w c� z 0 0 f - n U 0 -I1 11� To a. z 0 z w -_ I- W_ 4 U co 0 I o W 0 ❑ �0n z - W} zz oQ F LL 0 ❑ o w CONCEALED' 0 L WOOD O , BLOCKING F- Q � 24" AND w 60" AFF } � I w o >z Q} Imo_. 2 in o rY 6� w 0 J �q Z ❑ U Q FREEZER- o� I �n CONCEALED WOOD BLOCKING 24" AND 60" AFF P'LAM. SHELF W/ BRACKETS 6'-0" A.F.F. c�1 MOP HOLDER CD (10300) 48" HGT. FLOOR - SERVICE SINK LOCKERS N 0 I 10'-0 1/2" 5„ I 1 COUNTER REF. DET. 02/A8.2 & 03/A8.2 4 ..... 16, 3 A9.1a' qIA WOMEN'S 108 2.... r. . , C.G. CORRIDOR 2 WALL BUMPER 119 .30'X.'48.', (10300) 1 2'- 6'-2 1/2)) I,'.',' W.C. 5" 2'-10 1/2" CORNER .:.,.. C.G GUARDS (10500) TYP. ALL INTERIOR 2 CNI PARTITION _ lopp _ - - OUTSIDE CORNERS A9,1 MEN'S w EXCEPT 109 WHERE NOTED ..'.'.'....... COUNTER REF. DET, 02/A8.2 & 03 A8.2 ISOLATION ROOMn I 1 01 1 3 A9.1 2'-5„ 1 o MIN. z 03A 1 A9.1 i WORK ROOM €f" J i 118 \ 60" DIA. . . ✓ 5' - 4 1/2)) C G. ME CORRIDOR 1 w3 I JANITOR CLOSET 111 120 C.G. �tf z�c¢wwY •30 x 36 ELEC. I '•CLR. FLR.' ,AREA I PANEL L... _ .I - REFRIG. 1 06 --- i 3 2 A9.1 I 'f Cio I BREAK ROOM -- 112 CLOSET 110. - W - 5-8 1/2" 4,-91j Ilk 11, LARGE SCALE PLAN 05 REF.: A2.1 SOURCE: 1/4" = V-0" 1. TOP OF FLOOR SINK E��.,,,, , (-1") BELOW FINISH FLOOR ELEVATION 0'-0". 2. FINISH FLOOR ELEVATION AT ROOM PERIMETER IS CONSTANT (LEVEL) 0'-0". 3. SLOPE CONCRETE FLOOR SO THAT EPDXY FINISH ("FINISH FLOOR") IS 1/8" UNIFORM THICKNESS. 4. FLOOR SLOPE VARIES AS TO DISTANCE OF FLOOR SINK OR "SWALE" FROM WALL. SAWCUT AND REMOVE EXISTING CONCRETE FLOOR SLAB IN THIS ROOM IN ITS ENTIRETY, AS REQ'D. 5. FLOOR SINKS W/ REMOVABLE STRAINERS MUST BE INSTALLED FOR PROPER DRAIN ACCESS AND STORE OPERATIONS MAINTENANCE AT TUB ROOM. WALL BUMPER 2'-4" HGT. SIM. (10300) C. 2 -0 „ SF-06 -6 1 o ELEC 2" BLACK CN P NEL C'TOP x GROMMETS 'p FICE TYP. 48" I - I I : . •3s : O.C. MAX.Fiq I :' LR..: I 4 AREA : I 21 08 2 I-6 A- -:� / A9.1 _ rJ Lo 1 1 8.2- _ABV. INSTALL STORE «_ SAFE WHERE SHOWN ON F- PETCO'S "FINAL LAYOUT" STORE FIXTURE PLAN 13'-11" 5„ 11'-1 1/2" OFFICE PLAN REF.: A2.1 SOURCE: 04 1/4" = 1'-0" 2) TUB ROOM /CAGE RM FLR FINISH DETAIL 13 REF.: A2.1 SOURCE: 1/4" = V-0" FLOOR PIVOT FFOR DOOR / 1. CONTRACTOR FURNISHES AND INSTALLS ALL BIRD ROOM COMPONENTS (10300) TYPICAL FLOOR ANCHOR 2. REFER TO "BIRD ROOM LOCATIONS ASSEMBLY INSTRUCTIONS , FURNISHED BY PETCO VENDOR, FOR COMPONENT DIMENSIONS & LOCATIONS ^ Pq, 1 FIRE SUPPRESSION �. V PIPING, HVAC EXHAUST DUCT, ELEC. POWER , CONDUIT MUST BE LOCATED TIGHT, TO FIT INSIDE 12" DIA. (CLEAR INSIDE DIM.) DECORATION PROVIDE BY PETCO ABV, TO BIRD ROOM TO B.O. BAR JOISTS OF WALL BUMPERS SUPPLIED W/ BIRD ROOM KIT 1. CONTRACTOR FURNISHES AND INSTALLS ALL BIRD ROOM COMPONENTS (10300) 2. REFER TO "BIRD ROOM ASSEMBLY INSTRUCTIONS", FURNISHED BY PETCO VENDOR, FOR COMPONENT DIMENSIONS & LOCATIONS BIRD ROOM PLAN & ANCHOR DIA. DET. 06 REF.: A2.1 SOURCE: 1/4" = 1'-0" 4'-2" 4 13 __ 3 06 1 +7.") CLOSET A9 2 19'-10" I - CAGES TYP. cl-1 ------------- rq HWH\ CABINET W/ HAIR ' INTERCEPTOR 14 CAGE ROOM\ DRYER 107 \ AB. WASHER �n I :,.:�0Rx F 6 I 1 / ALIG ELEC. J tr ','AREA PANEL, \ / 4'- DRY R VE`1` w 1� I THRU ROOF, 11 CONCEALED IN 3 1 A9.2 �.. PARTITION/REF. MECH. 10'-9" 2 GROOMING ROOM 106 I EYEWASH STATION(10300) HAING I 3'-O" _I p - HR WALL 0� WALL H.RI G --- WA L. wAtL- Ln o 0 1 4 I TUB ROOM o� ;I L1 A8.1 105 71- - cn Ate" 4 � H.RI� H.RING WALL - - - - - - - - - - - - - - " WALL 01 -�j GROOMING 3 A9.2 1 i COUNTER 2 � I f 1-�3 fL------ � - START OF TILC�� 1:�3.1 O9 U3 WAINSCOT A8.1 GROOMIN i A8.1 RECEPTIC 14 I 5 -8 I 104 CiN 11'-7" I STOREFRONT BUMPE STOREFRONT SF-03 _ _ SECURE TO AL. SEE NOTE #4 MULLION (10300)- N, -UI GROOMING LOBBY/WAITING °O 1031 6'- 0 1/2" 11'-11 1/2" 5' 10" -TOREF ONT SF-C SEE NOTE #4 0 05 03 A.�� ° 8.1 .�; > - 1 1. "H.RING/WALL" = WALL MOUNTED HITCHING RING REFER TO DET. 10/A8.2 2. DIMENSIONS SHOWN ARE TO (F.O.F.) FACE OF FINISH 3. AUTOMATIC SLIDING ENTRANCE DOOR UNITS' PIVOTING "BREAKOUT" DOORS ARE SHOWN DASHED. 4. (2) 8"x 14 GA C-JOIST BOXED HEADER (TYPICAL FOR ALL HEADERS ABV. STOREFRONT) 02 A8.1 FULL LENGTH THRESHOLD BY AUTOMATIC DOOR MFR TYP. Zvi-~ o I I I > Z I O a III- VESTIBULE Lu CD I> 11011 bi i �-_ - - ....- ......... 08 r 8'-6" UNIT 00J A8.'I 8'-6 1/2" R.O. --A8'.I SIM. � 10'-2 1/2" If SEE NOTE #4 LARGE SCALE PLAN REF.: A2.1 SOURCE: i 00 I z Y) L z I �U ........... 0 \A8.1 Lf) 16 07 01 1/4" = V-0" I- --- -;i. - _ 11 1 Architect Jarnes Cohen License It: 00.15903 J C] J Q m _ ZU) ILL- h 06 ❑ ❑ <� O-� ®mf-❑_ ILL u�� z U L! W W LLI D , o IL, u) (O, [-- z z 11 ou¢ t �(1)(0 1 W J Z 0 Q'vl. n °o od =W N IL�< fn DISTRIBUTION. DA'rE: PERMIT 08/13/04 0 ADDENDUM Ik2 10/21/04 SBLM JOB# PE-fcO P.M. JOB µ 04075 00000 DRAWN: GIIEGKCD: MR/DB MR/SS DRAWING TITLE: LARGE SCALE PLANS AT 1 0 w J I- w 0 Y L w T I- z 0 0 a 0 0 a z 0 rn z w p w vi I- w W¢ �a ow U � C] (n Q° z L oa p a 0 o� Z U Ow (� T z� F- Q v) w T r� LL>_ w� >0 z } <IJ_. 2 Q in 0 �a OJ U � 2 U) 0 z s EXISTING EXTERIOR AL. STOREFRONT EXIST. STRUCTURAL COLUMN .............. l�J....._._l INSIDE F.O.F. ABV. - �___--J ALUMINUM COMP TS SEALANT AT CONTACT AGAINST EXT. I ==------ (1) LAYER 3/4" INT PLYWD. SUP IED W/ D ROOM KIT STOREFRONT, FONT, VERT. & HORIZ., TYP. PROVIDED BY CONTRACTOR, OD FLOOR ANCHOR BRAKE METAL AT "11/A8.1 SIM" SECURE TO UNISTRUT W/ #10 D W/ BIRD ROOM KIT BRAKE METAL ON FR. TR. PLYWOOD 0 SEALANT AN I SELF TAPPING SCREWS 12" O.C. (2) 3-5/8 x 1-5/8 x 12 GA. POST BACKER ROD UNISTRUT ROOF BRAKE METAL ON VW_ PLYWD._BLKG.SYSTEM SUPPLIED .FLOOR ANCHOR EPDXY-------- - 1 WITH BIRD ROOM KIT ° a q . PROVIDED BY CONTRACTOR M.D.F. TRANSOM •: v 1/2" X 2-3/4" EXPANSIO BOLT THRU (2) SLOTTED Z z SUPPLIED WITH BIRD GALV. L 3-1/2 x 3-1/2 x c~n ROOM KIT 1. CONTRA FURNISHES AND INSTALLS ALL BIRD ROOM 1/4 x 3 FLOOR ANGLES �/ I �" w O BIRD ROOM KIT P CHASED COMPO S (10300) " " BY CONTRACTO ASSEMBLED L3-1 2 x 3-1 2" x 1 4 x / / / & INSTALLED CONTRACTOR FER TO "BIRD ROOM ASSEMBLY INSTRUCTIONS", FURNISHED 3" FLOOR ANGLES ( BREAK METAL FILLER CONT. (103 PETCO VENDOR, FOR COMPONENT DIMENSIONS & LOCATIONS AUTO SLIDING �l. FINISH TO MATCH STOREFRONT b - - DOOR UNIT ^�1�� p Q BIRD ROAM FLOOR DETAIL 17 ' STOREFRONT PLAN DETAIL/1' 16 F1 REF.: A2.1 SOURCE: N.T.S. REF.: 04/A3.1 SOURCE: 3"=1'-0" - ;.: AL. STOREFRONT 21/4" 21/4° AL. STOREFRONT AL. STOREFRONT SEALANT TYP. r L3-1/2" x 3-1/2" x 1/4" r WD BLKG.TYP. SUSP. ACT. PROVIDED BY CONTRACTOR, SUSPEND FROM +: 3 FLOOR ANGLES �. (2) 8"x 14 GA. C-JOIST L-TRIM & SEALANT UNISTRUT BOXED HEADER _ 3/8" TEMPERED GLASS PROVIDED BY CONTRACTOR 7 r' ;, 5/8" GYP. BD. ON N BRAKE METAL ON LZ PLYWD. BLKG.��4 (08800) SILICONE BULLNOSElic SEALANT TYP, SURROUND AT �' `.,; 3-5/8"x 20 GA. MET. FRAMING © 16" O.C. AL. FRAME & AL. DOOR TUB ROOM SIDE ;;` ;;. L-BEAD AND CAULK (� C- �G SUPPLIED WITH BIRD ROOM KIT BULL NOSE TILE BRAKE METAL I f _ -��j-���� AT TUB ROOM WD. BLKG. _ �— 1/4" TEMPERED GLASS PROVIDED BY CONTRACTOR (2) 3-5/8"x 1-5/8"x 12GA. CONT. SEALANT, TO BOXED HEADER ABOVE L3-1/2" x 3-1/2" x 1/4" / �' BOTH SIDES o - SUSP. ACT. =, (08800 ) 1/4" SHIM 1/2" X 2-3/4" EXPANSION BOLT ¢ 3" FLOOR ANGLES 1. CONTRACTOR FURNISHES AND INSTALLS ALL BIRDCD THRU 2 SLOTTED GALV. L () STIBU VE LE AUTO SLIDING fi ROOM COMPONENTS (10300) CERAMIC TILE �' ,y; CERAMIC TILE 3-11/2 x 3-1/2 x 1/4 x 3 SIDE DOOR UNIT 2. REFER TO "BIRD ROOM ASSEMBLY INSTRUCTIONS", FINISH ON ',;. FINISH ON TUB GROOMING ROOM 1" ROOM SIDE 0 O FL R ANGLES 1/2" X 2- " EXPANSION BOLT T FURNISHED BY PETCO VENDOR, FOR COMPONENT ;, SIDE :�.; I - BRAKE METAL (2) SL D GALV. L 3-1/2 x 3-1/2 x 1/4 3 FLOOR ANGLES DIMENSIONS & LOCATIONS BIRD ROOM SECTION DETAIL 1 15 NT. STOREFRONT HEAD/SILL DETAIL 14 VESTIBULE CORNER PLAN,DETAI 1 13 STIBULE SECTION DETAIL 12 STOREFRONT PLAN DETAIL 11 REF.: SOURCE: N.T.S. EF.: 04/A3.1, 01/A7.1 SOURCE: 3"= 1'-0" REF.: 11/A7.1 SOURCE: 311= 1'-0" R 01/A5.2 SOURCE: 3"= 1'-0., REF.: 01/A7.1, 04/A3.1 SOURCE: 311= 1'-0" INTERIOR SIDE OF EXTERIOR I'... ' (2) 3-5/8% 1-5/8"x 12GA. CONT. STOREFRONT 6 7/8" fi ;;,. ; TO BOXED HEADER ABOVE * MOUNT WALL BUMPER TO HORIZONTAL MULLION IF WITHIN THE PTD. 3/4 MDF CAP AND SIDE TRIM, EASE ALL EXPOSED EDGES .• •�•• z 1/2" X 2-3/4" EXPANSION BOLT THRU (2) � SLOTTED GALV. L 3-1 2 x 3-1/2 x 1/4 x 3 MIN./MAX. HGT_S. SHOWN AL. STOREFRONT T.O. CAP .t•, w FLOOR ANGLES PROVIDE AL. SAFETY RAIL (08410) SEALANT TYP. 3 -4 :/ ul BRAKE METAL FOR WALL BUMPER MOUNTING TO WD BLKG.TYP. v PTD. GYP. BD. '.f __L-TRIM CAULK TYP. & L3-1/2" x 3-1/2" x 1/4" x ¢ 3" FLOOR ANGLES EXTERIOR STOREFRONT IF THERE IS NO HORIZONTAL MULLION WITHIN THE L—TRIM & SEALANT T.O. STEEL POST L-TRIM ALL SIDES CORNER GUARD •. I I 1/4 OF OPENING ALIGN F.O. AL. _ Q - I N 1 MIN./MAX. HOTS. SHOWN N (TYP.) ,- CV a Q L� I I STOREFRONT _ POST AT END/ REF. DET 05/A8.1 w/ 'RETAIL' -SIDE PARTITION Ow ^r _ r " ' I F.O.F. TYP. ALL INTERIOR O> AL. STOREFRONT I I I ALIGN �,• " CAULK TYP. 2 1 /4 WALL BUMPER 10300 ( ) I 7 1 /2' AUTO SLIDING DOOR UNIT PROVIDE ENDCAPS AT SAFETY RAIL ENDS }•,;; • BRAKE METAL FIN. FLR. I 3 1/2" WD. BLKG. TYP. ADOPTION AREA WALL CAP 10 INT. STOREFRONT JAMB DETAIL 09 VESTIBULE CORNER PLAN DETAIL 08 STOREFRONT BUMPER DETAIL 07 STOREFRONT PLAN DETAIL 06 REF.: 01/A7.1 SOURCE: 3"= V-O" REF.: 04/A3.1, 01/A7.1 SOURCE: 3"= 1'4' REF.: 11/A7.1 SOURCE: 3"= 1'-0" REF.: 041A3.1 SOURCE: 3"= 1'-0" REF.: 01/A5.2, 04/A3.1 SOURCE: 3"= V-0" 4 -1/2" r (2) 3 5/8" x 1 5/8" x 12GA. �• INSIDE F.O.F. MET STUDS AT LOW WALL HGT. WITH 5/8" GYP. BD. --� -- --� i BOTH SIDES (NOTCH STUDS AND FLOOR ANGLES •- PTD. GYP. BD. CAULK TYP. EA. SIDE L-TRIM ALL SIDES OF OPENING GYP. BD. L-TRIM __ _ __ _ - � DOOR UNIT (ONLY) �� 1 2 RISER CLOSURE BY DOOR UNIT MFR. / / INTERMEDIATE r HORIZONTAL AL. SECTION " - 4-1 2 AL. BASE ->- ; HSS POST 2 1/2" x 2 1/2" x _-J :,• I / / _ ON 'RETAIL' SIDE, 1 TYP. ALL SIDES _ _ _ __ 3 x 6 x 20 GA GALV. MET. BACKING PL. 24 O.C. VERT., BOTH SIDES TYP. 1 T.O. FIN. FLR. BED IN SEALANT , „ 3 -3 1/2" HGT. ' OF OPENING IIIIII IIIIIIII IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII11111111111 SEALANT __________________________J WOOD PARTITION CAP ABOVE :.,� 1/4 SHIM SIDELITE (VESTIBULE SIDE) r AL. SILL FLASHING i CAULK 1 1/2" 1 3/4" 1 3/4" 1 1/2" (2) STAGGERED FLAT PHILLIPS FRP Ir 20 GA. x 6 GALV. MET. BACKING PL. - - ...... .-`................................... 'l............... �� "" I (2) 3-5 /8x 1-5/8x 12GA. POST (2)GALV. L 3-1/2x 3-1/2x 1 1�x 3" SLOTTED ANGLES / 1/2" THRESHOLD, (1:2 MAX. SLOPE) BY DOOR UNIT MFR. SEALANT BED (EXTERIOR DOOR UNIT) ENTRANCE MAT REINF. CONC. SIDEWALK W/ » 1/2 E.J. SEALANT & COMPR. FILLER — r- ---`: i --- HEAD 3/8" DIA. x 2 3/4" (10300) I - _ - - -1 , SLEEVE ANCHORS TYP. EA. ANGLE - , WALL BUMPER (10300) (1) 1/2" x 2-3/4" EXPANSION BOLT T.O. FIN. FLR. - h...................I .......... .......... I ........ ............. L.... _ + I I I` .; ON RETAIL SIDE w/ THRU (2) OPPOSING, SLOTTED STEEL ' N L--- - I HSS POST 2 1/2" x 2 1/2" x 5'-0" FASTENERS 6" O.C. BASE ;,''; ,;:; MAX. - " - - ANGLES (VESTIBULE SIDE) DOOR OPENING I I HGT. >� (2) GALV. L 3-1/2" x 2-1/2" 1 /4" x 2 1/2" I;", T.O. CONC. DETAIL SHOWN AT INTERIOR AUTOMATIC SLIDING ENTRANCE DOOR / EXTERIOR FLOOR ANGLES CONDITION SIMILAR. ADOPTION AREA WALL DETAIL 05 INTERIOR STOREFRONT SECTION DETAIL 04 VESTIBULE SECTION DETAILS 03 ENTRANCE DOOR SECTION DETAILS 02 STOREFRONT SECTION DETAIL 01 REF.: 01/A7.1 SOURCE: 3"= V-0" REF.: 04/A3.1, A7.1 SOURCE: 310= 1'-0" REF.: 01/A8.2 SOURCE: 311= 1'-0" REF.: 11/A7.1 SOURCE: 3"= V-0" REF.: 04/A3.1 SOURCE: 3"= 1'-0" c 0 c CD m 6_ (D a o r co Y (n a) N U ,� � N N r`--• � r � z 'aN (D x I w w fn z I- LL. CfD Architect: Jarnes Cohen License It: 0015903 J r�r Q 0 ZC ILL 06 > O 0 .� L1 I__ In z o (� a w� Q F_ O -' U) Z U LL O c�0 a_LL U z00 u� �: <<. p w I-- u) to � m VY""j amulllJl �IWllIL'll 3 �I Ad lu i tuW in O DISTRIBUTION. DATE: PERMIT 08/ 13104 ADDENDUM 92 10/21/04 SBLM JOB# PETGO P.M. JOB)1 00000 DRAWN: CIIECKED: DRAWING TI [LE: INTERIOR DETAILS A8.1 MECHANICAL PLAN REF.: NOTES REF.: GENERAL HVAC NOTES: 1. SEE STRUCTURAL DRAWINGS FOR EXACT PLACEMENT OF ROOFTOP HVAC UNITS, EXHAUST FANS, SUPPLY AIR AND RETURN AIR OPENINGS AND LOCATIONS THROUGH ROOF. CAREFULLY LOCATE ROOF TOP UNITS SUCH THAT CONCENTRIC DIFFUSERS FALLS IN A STRUCTURAL BAY. 2. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT PLACEMENT OF CEILING DIFFUSERS AND GRILLES. 3. TEMPERATURE IN THE BIRD ROOM AND SUPPLY ROOM MUST BE MAINTAINED AT A MINIMUM OF 75'F. 4. INSTALL DUCT SMOKE DETECTORS IN ACCORDANCE WITH NOTES ON ROOFTOP UNIT SCHEDULE AND HVAC GENERAL NOTES. 5. EXHAUST FANS IN OPEN RETAIL AREA ARE DIMENSIONED SO THAT THE EQUIPMENT IS LOCATED IN CLOSE PROXIMITY TO THE STORE FIXTURES THEY ARE SERVING. THE PURPOSE IS TO MINIMIZE ANY OFFSETTING OF DUCTWORK FOR COST AND AESTHETIC REASONS. CONTRACTOR MAY LOCATE FANS UP TO 12" FROM LOCATION SHOWN TO AVOID STRUCTURE AND OTHER INTERFERENCES. VERIFY WITH PETCO PROJECT MANAGER DURING THIS PROCESS. 6. UNLESS OTHERWISE NOTED, ALL DUCTWORK SHALL BE RECTANGULAR SHEET METAL AND SHALL BE INSULATED. EXPOSED DUCTWORK SHALL BE INTERNALLY LINED WHILE CONCEALED DUCTWORK SHALL BE WRAPPED. REFER TO PROJECT MANUAL FOR DETAILS. THE CONTRACTOR, AT HIS DISCRETION, MAY USE ROUND DUCTWORK WITH PROPERLY INSTALLED EXTERNAL DUCT WRAP INSULATION IN CONCEALED AREAS, AND MAY USE SPIRAL, INTERNALLY LINED DUCTWORK IN EXPOSED AREAS. 7. IN EXPOSED AREAS, ROOF OPENINGS FOR HVAC EQUIPMENT SHALL BE LIMITED, WHERE POSSIBLE AND PRACTICAL, TO ACCOMMODATE 'THE DUCT OPENINGS AND NO MORE, THE INTENT BEING TO MAINTAIN A NEAT AND AESTHETICALLY PLEASING FINISHED PRODUCT WITH AS MUCH OF THE ROOF ITSELF INTACT AS POSSIBLE. 8. REFER TO SHEET E2.5 FOR LOCATION OF CONTROL DEVICES. HVAC KEY NOTES: Ol NOT USED. NOT USED. NOT USED. U LOCATE THIS ROOFTOP UNIT SUCH -THAT THE SUPPLY AND RETURN DUCTWORK FROM THE UNIT ARE WITHIN THE WALLS SURROUNDING THIS AREA (NO EXPOSED DUCTWORK ON RETAIL SIDE OF WALL). O THE ROOFTOP PACKAGE INCLUDES A PREFABRICATED CONCENTRIC RETURN/SUPPLY DIFFUSER FOR EACH ROOFTOP UNIT AS SHOWN, TYPE CCD 46" X 34" (REFER -TO DIFFUSER AND REGISTER SCHEDULE). CONTRACTOR SHALL FABRICATE SHEET METAL DUCT - EXTENSION TO MEET PROPER OUTLET HEIGHT. OUTLET HEIGHT SHALL RANGE BETWEEN 15'-0" AFF TO BOTTOM OF DIFFUSER (MIN.) AND 8" BELOW STEEL TO TOP OF DIFFUSER (MAX.). ALL DIFFUSERS SHALL BE THE SAME HEIGHT. THE HVAC CONTRACTOR SHALL PROVIDE MISC. STEEL (CHANNELS, ANGLES, ETC.) TO SUPPORT DUCTS, DIFFUSER, PLENUM AS REQUIRED. CONNECT MISCELLANEOUS STEEL TO BUILDING STRUCTURE IN A MANNER ACCEPTABLE TO THE ARCHITECT. THE HVAC CONTRACTOR SHALL ADJUST THE PATTERN OF THE SUPPLY AIR OUTLETS AS REQUIRED (0 PROVIDE APPROXIMATELY EQUAL AIR QUANTITIES AND FULL COVERAGE OF THE RETAIL AREA. IF REQUIRED BY FIELD CONDITIONS, IRREGULAR AIR FLOW PATTERNS OR UNEQUAL AIR FLOWS MAY BE OBTAINED BY CLOSING FRONT VANES AT ENDS OF OUTLETS. O6 14" X 14" WALL TRANSFER GRILLE (WT'G). MOUNT BOTTOM AT 14'-2" AFF O 10" X 10" WALL TRANSFER GRILLE (WTC). MOUNT BOTTOM AT 14'-2" AFF WOMEN MEN'S 109 ISO ROOM 117 \p WORK ROOM CLOSET L - 120 BREAK RM 112 CLOSET-- 110 PRE -SALES 02 KEY PLAN 1/8" = 1'-01' REF.: PROFESSIONAL ENGINEER Duane S. Henderson FL PE# — 46179 CLOSET r 114CAGE R= 105 TUB ROOM 1 66 GROOMING SALON tea 107 GROOMING RECEPTION 104 VESTIBULE 101 AQUARIUM - AREA 115 OFFICE --113 U-Ell HIV I� 01 NO SCALE J CO -I .J Q ■ CO z L- G 06 �w om ❑ z O Unn < (n FW- 0 z0u w W WD 0 WO �0 U J ILL 3::�Ez � O(nU) r 01 Ah a Z 0°_ •Aft Akgo �U OQ 9L�o zW N o Ul UIS"rRIBUrION: DArE: 25% REVIEW 07/19/04 75% REVIEW 07/28/04 98% REVIEW 08/06/04 PERMIT 08/13/04 ADDENDUM #2 10/20/04 HEI JOB # PE"rC0 P.M. JOB # 0450000526 DRAWN: CHECKED: JCC KB DRAWING TITLE: MECHANICAL PLAN M2.1 jo 1/�qL4'1 NOTES PROI DU REF.: GENERAL HVAC NOTES: 1. REFER TO MECHANICAL SCHEDULES FOR APPLICATIONS OF ROOFTOP HVAC UNIT DISCHARGE PACKAGES. - - L____�---�-" 2. MAINTAIN MINIMUM 10'-0" BETWEEN OUTSIDE AIR INTAKES AND ANY EXHAUST OUTLET OR PLUMBING VENT. E01 85 \� \`:> �% 3. REFER TO SHEET E2.5 FOR LOCATION OF CONTROL DEVICES. L._, -- -' - - - - - r 4. ALL DUCTWORK IN AREAS WITH SUSPENDED CEILINGS SHALL BE CONCEALED ABOVE CEILING. CD1 I 5. CONTRACTOR MAY AT HIS DISCRETION, USE ROUND DUCT OF 75 I - - ---- -------- - --- --------------- --- EQUIVALENT SIZE IN LIEU OF RECTANGULAR IN CONCEALED AREAS. DUCT SHALL BE INSULATED AS SPECIFIED. —....a__ .._ L ON ROOF I t 2 T I `�" 18-' CD1 HVAC KEY NOTES: I EF @ i i � � ,- __L ,2 4 i I V . J ` 550 1 14" ROUND DUCT UP TO EF 1 ON ROOF. O I I CD1 O GRILLE WITH HINGED FRAME FOR INTEGRAL, CLEANABLE FILTER. 120 DN 12"0 550 i O3 4" DIAMETER RIGID GALVANIZED DRYER VENT, IN WALL SPACE, _._,_,__--- __,_„_-,____ v______ THROUGH ROOF WITH VENT CAP. LOCATE VENT 8" LEFT OR FRG ( - -- RIGHT AS REQUIRED TO AVOID DUCTWORK ABOVE CEILING OF ,' \ 3 I J CENTERLINE OF DRYER 5" AFF. USE 90', 4" CLOSE ELBOW 1100, 14x14 \� 4' TRANSITION FROM DRYER VENT TO VENT DUCT IN WALL. INSTALL f I \ t-E- --� - -_ /\ PER APPLIANCE MANUFACTURERS INSTRUCTIONS. USE STRAIGHTEST DUCT RUNS POSSIBLE TO OUTSIDE. -IJ I _ I FRO 8„ NOT USED 550 i f. _.. � __- ,•'�-- -� i `..--_-___ I �r 16x16 . ✓ 2 C I E \ I O 8" SPIRAL FROM ROOF EXHAUST FAN TO BELOW 'FOP OF PLASTIC TUBING OF ANIMAL HABITAT FIXTURE. WHERE REQUIRED _ f CD1 I ( I 12x12 (TYP) 15 _— TO AVOID CONFLICT, PROVIDE MINIMAL OFFSET IN DUCT' JUST I i I EG1 " I 3.`l BELOW BAR JOIST. RETURN TO SITE AFTER HABITAT IS I ` G--75 f ,-- • 85 I I i INSTALLED AND PROVIDE 4" FLEXIBLE EXHAUST DUCT DOWN 11 `;� I 4 PREFABRICATED PLASTIC TUBING TO AIR DISTRIBUTION SPH R C _ Q 1 I 400 CD1 AND AIR DISTRIBUTION BOX. TUBING AND SPHERE FURNISHED BY ------------ PETCO VENDOR. AIR DISTRIBUTION BOX BY MECHANICAL O \ CONTRACTOR. MECHANICAL CONTRACTOR TO COORDINATE I � .. 14"x14° INSTALLATION WITH PETCO V WALL I ----` �---------- i VENDOR. SEE DETAIL 02 M3.2. I � II TRANSF R GRILLE I 10'� _ ___._.__{-- ---- � - i (WTG)• MOUNT 1 4" EXHAUST FROM AIR DISTRIBUTION BOX IN PLASTIC AIR *--, r DISTRIBUTION SPHERE TO HABITAT INSIDE PLASTIC TUBING. � ___ • . • _ BOTTOM 13 -2" AFF. , .�� 750 __ ____ _) I 2 TYPICAL FOR ALL FOUR (4) HABITATS. TUBING FURNISHED BY rG1 a I I -`"` O 'ON --ROOF-- PETCO VENDOR. MECHANICAL CONTRACTOR TO COORDINATE 2 300 oD EG1 I 18 EF I INSTALLATION WITH PETCO VENDOR. USE EQUIVALENT LENGTH 250 , EF 3., I CD1 X ; DUCT IN ALL LEGS OF HABITAT FOR INHERENT BALANCE OF AIR 7 ON ROOF � �� -1` .. 1._-- 18'" I SYSTEM. E02 I I 400 ,��-- rb-1 3.? COORDIN TE THE LOCATION OF EXHAUST 50 I I 10"� - -�-_ - � O OWNER'S AFURN FURNISHINGS AND OTHER ETRADES. REFERTO WITH THE I^ l___....i __ I _ J F - - I t I 16 (TYP) ARCHITECTURAL PLANS FOR DESIGNATED, LIMITED AREA FOR _ 7-7 i I 3.7 EXHAUST DUCT AND OTHER TRADES' WORK. I' I 8 10" ROUND DUCT UP TO EF ON ROOF. ` . ' i \ I ( i • ••• ....2 •�\��x18 12"�-'1 ....::.' r u (12x12Dl I I I f FG1 I I RTU 13 [ -- 500 150 I 5 3. \ 15 181 I �\ 3.2 U -EF- 3; I �`,.. (TYP) ON ROOF I Qc_ -- I I � tl CD1 1 180 I t I I I I I I I I a OPEN 07 LARGE SCALE GROOMING PLAN 07 f f I ii j I cot i u= r- n I EG21 i i F : /A /4 0 REF.: 02/M2.1 1/4" = 1'-0" I _- ., II - ill, - I - -- I 2 CD1 _ I ORIENT CUH SUCH 150 I THAT DISCHARGE AIR 2 DOES NOT DISCHARGE ----, TRANSFER GRILLE IN -'-- "-" DIRECTLY ON CAGES. j ' ' _ CEILING. PROVIDE 1 I 10"x10" WALL GRILL IN PLYWOOD `� \ // DECK AND DUCTWORK TRANSF R GRILLE \ AS REQUIRED. - _ (WTG). MOUNT --.—•� I I I- ----- -- _ ----_" - TG1BOrrOM 13-2" AFF. 1 2 71I „ 0WOMENS180 Z 5 05 CLOS ETTG1 108 1�0 EF 0 ROOF 3• MEN ti3• CAGE ROOM18 2 rYP) 105 ISOROOM / 02 V' • , 3 TUB ROOM EF 18 WORK �� \ `\ ROOM GROOMING SALON ON ROOF CLOSET FEG \\ rYP - I -- - - - -- - \ r�t"' -r 107 6 GROOMING _� - -- I O �-� / `` 112 l j ( 104// .;, BREAK RM G;, �; j I` I � RECEPTION CLOSET _.o VESTIBULE m I 101 PRE -SALES AQUARIUM AREA i _. I-/✓r 1 115 ,.� OFFICE • cl c� 04 N 3. U L U N L LARGE SCALE HVAC PLAN 05 LARGE SCALE BIRD ROOM PLAN 04 OPEN 03 LARGE SCALE HABITAT PLAN 02 KEY PLAN 01 O J REF.: 02/M2.1 1/4" = V-0" REF.: 02/M2.1 NO SCALE REF.: N/A NO SCALE REF.: 02/M2.1 NO SCALE REF.: NO SCALE -ESSIONAL ENGINEER ane S. Henderson FL PE# — 461%9 Q j O CC)0 � o r-v U rJ o c� �w-Or7W CwD V) (� �CO�ZO�N 0� �l oo�Q O f7 W haN �rnz��� X �:LUO, LZ W QwL, O a.X w J r Z F) r O J ' w i— J Eo J m e LL G ® 06 vJ 0� J w 0 cot- o -® 0 .� 0� Z E w cmUcnZULL Q O ° �ww U_j0 WD 0 Wo 0. 0 F-- — O d. O w Amw (V s W Y edO0. a� dL s(9 cC p DI:•,rRIBUTION: DArE: 25% REVIEW 07/19/04 75% REVIEW 07/28/04 98% REVIEW 08/06/04 PERMIT 08/13/04 ADDENDUM #1 08/19/04 ADDENDUM #2 10/20/04 HEI JOB N PETCO P.M. JOB t� 0450000526 DRAWN: CHECKED: JCC KB DRAWING T1TU- MECHANICAL LARGE SCALE PLANS AND DETAILS M 3.1 S I I i (z I .. l I I [ I i I I iI � 'r \ 5 MINIMUM REQUIRED IINVERT 96.26' TO CONNECT INTO SANITARY SYSTEM I II I I I I i I ' I I I I 6 "S—FP F ) C` �D1 I(J I I I r -; 5 5 , L -4 W, =�-- _.. I COF', r_ 1/8" PER i FOOT SLOPE .............. - ............ Cr' 1 -0" 4 1 _ 1 /2'-CW - 1/2"HW i 1 3/4"FW - I I iI I I i I I I 1 I NOTES REF.: GENERAL PLUMBING NOTES: 1. INSTALL WATER PIPING AS HIGH AS POSSIBLE TOWARD ROOF STRUCTURE. 2. INSTALL TRAP PRIMERS TO ALL FLOOR DRAINS TO MEET LOCAL CODES. 3. COORDINATE ALL UTILITY CONNECTIONS WITH LANDLORD AND UTILITY COMPANY. 4. INSTALL 4" SOIL AND WASTE PIPING AT 1/8" FALL PER FOOT. INSTALL OTHER SOIL AND WASTE PIPING AT 1/4" FALL PER FOOT. SLOPE TOWARD POINTS OF CONNECTION. FIELD VERIFY FINISHED FLOOR ELEVATION AND INVERT ELEVATION OF EXISTING SOIL/SEWER PIPE FOR POINTS OF CONNECTION. 5. REFER TO MECHANICAL EQUIPMENT SHOP DRAWINGS FOR ORIENTATION OF UNITS FOR ACTUAL ROUGH -IN LOCATIONS. PLUMBING KEY NOTES: _.. ____._._ _ _--_-- __-____.____________ .____ .__._.__-________ _ __• �_- - O COORDINATE AND INSTALL NEW TENANT'S 2" DOMESTIC WATER CCONNECTION INTO THE BUILDING'S 2" WATER SERVICE ENTRANCE. O2 COORDINATE AND INSTALL ROOFTOP UNIT CONDENSATE DRAIN WITH P- ;' I I \ TRAP. EXTEND DRAIN LINE AWAY FROM UNIT WHERE CONDENSATE DRAINAGE FLOWS TO NEAREST ROOF DRAIN AND DOES NOT COLLECT IN WORKING AREA AROUND UNIT. 3 NO PLUMBING PIPING SHALL BE ROUTED OVER ELECTRICAL PANELS i P� I �O AND/OR CLEAR SPACE. i i O4 COORDINATE AND INSTALL A GENERAL PURPOSE HOSE BIBB TO THE BOTTOM SIDE OF THE ROOF DECK NEXT TO THE ROOF HATCH WHERE INDICATED ON DRAWINGS. HOSE BIBB SHALL BE SECURELY ATTACHED TO STRUCTURE TO AVOID HOSE BIBB FROM BEING PULLED FREE FROM THE ROOF STRUCTURE. HOSE BIBB TO BE INSTALLED CLOSE ENOUGH j I TO ROOF HATCH THAT THE SERVICE PERSON CAN CONNECT A HOSE __ e` I WITHOUT HAVING TO REACH OUT AWAY FROM LADDER. HOSE BIBB 1/8 PER I RTU ELECTRIC __ �, , I ( SHALL BE INSTALLED NOT TO INTERFERE WITH PASSAGE THROUGH 6 TONS r - " FOOT SLOPE 5 � � ROOF HATCH OPENING IN ANYWAY. , ---4 W -@- i---4 WF::. i I 5 ONCE OUTSIDE THE BUILDING SPACE, COORDINATE AND CONNECT 'NVERT� COF /j _I __ ; t-=f _ �O TENANT'S SANITARY SERVICE INTO LANDLORD'S SANITARY SERVICE AS 97.33 w At� SOON AS POSSIBLE. CONTRACTOR SHALL FIELD VERIFY THE EXACT o ELECTRIC RTU_ :V�;::::� 10 TONS 2 r� r LOCATION AND INVERT ELEVATION FOR TENANT'S SANITARY SERVICE w� ,` 2 )�-_-_=--=z—� i-.-.__.__.( CONNECTION POINT BEFORE ANY WORK BEGINS. IF FOUND THAT THE CONNECTION POINT CAN NOT BE MADE, CONTRACTOR SHALL NOTIFY 000 r ` `'' 2. I I ARCHITECT AS SOON AS POSSIBLE FOR ISSUE TO BE RESOLVED NOT ELECTRIC i__� �� I TO DELAY CONSTRUCTION SCHEDULE. 10 TONS i - _ I _ ........ \\`'� (TM. _. 6 FIRE PROTECTION AND DOMESTIC WATER SERVICES PROVIDED BY L-__--:IG. �J.I t O 1 /2"HW _ - I ' - - "-_ 1-1/4"CW ° "- ` �_=" -\� -- - —1 =1�4"CW- - -- -� - - -- - - OTHERS. REFERENCE THE BUILDING SHELL DRAWINGS FOR THE -- 3/4"FW - - ' 1/2" Cyy ' DOMESTIC WATER METER AND BACKFLOW DEVICE LOCATION AND /I % INSTALLATION AND THE CONTINUATION OF SERVICE LINES. PIPJNG INSTALLED AS - 1/2 HW \ PIPING INSTALLED AS OIGH IN ROOF - - _ L- 3/4"FW ``_� i HIGH IN ROOF STRUCTURE AS POSSIBLE -___-______ �� STRUCTURE AS POSSIBLE , �`�\ �\\ I IBLE I _ >411 I - I � 1 - ------ - -- - - - —t ' �. `:.�..7 - - - j RTU ELECT[ 2"CW I1II111.1��IIt�1lJI���ILQLL�IILI I PIPING INSTALLED AS HIGH IN, (ROOF `V s,rRUC'[ RE AS POSSIBLE 3/4"CW 2CW 0 r i1tCOsst11 FIRE PROTECTION ENTRANCE \��'-�� �'`�"��'._i`�. "�✓`�1^•✓��1"�_1^_✓w _� ��"ter ._i-••_�" _, �..�-" .��.- I ELECTRIC 10 ,TONS I i / I PLUMBING FLOOR PLAN REF.: WOMEN'S 108 MEN'S 109 ISO ROOM 117 WORK Root, 11a CLOSET 120 BREAK RM 112 CLOSET 110 PRE -SALES 02 KEY PLAN 1/8" = V-0" REF.: 7 PROFESSIONAL ENGINEER Duane S. Henderson FL PE# — 461 %9 CLOSET or FLl_LlL42JI CAGE ROOF 105 TUB ROOM �-106 GROOMING SALON I 107 GROOMING RECEPTION 104 )VESTIBULE 101 AQUARIUM AREA 115 OFFICE 113 01 NO SCALE U p o r. v o w o o co W W LLJLy CO W � rw N�GNLd W (fl W�. ('OF iq ^ Y 'if)W pL�— LW W G � WW `LV - JLrr)� ' p W r7 w w w J J CO LL 06 ZU < o ❑ ®� Quo° wzwm U� U) ZULL ~®- OvW0 wD wo OUWUQ N •p� ®+ z° 0U OCTId (96 W w cl u, zz .r, 4 ur>7 DISMMUrION: DATE: 25% REVIEW 07/19/04 75% REVIEW 07/28/04 98% REVIEW 08/06/04 PERMIT 08/13/04 ADDENDUM #1 08/19/04 ADDENDUM #2 10/20/04 HEI JOB >f PETCO P.M. JOSS H 0450000526 DRAWN: CHECKED: JMM DKS DRAWNG TITLE: PLUMBING PLAN P2. 1 ISTARTING n c^ I--- i -r A rej --4" W LARGE SCALE BACK OF HOUSE PLAN 05 REF.: 02/P2.1 1/4" = 1'-0" NOTES REF.: GENERAL PLUMBING NOTES: 1. VERIFY ALL DIMENSIONS WITH THE PETCO VENDORS. 2. REFER TO ARCHITECTURAL DRAWINGS FOR TUB ROOM FLOOR DRAIN LOCATIONS AND TUB ROOM FLOOR SLOPE INFORMATION. 3. ALL DIMENSIONS ARE FROM THE INSIDE FACE OF UNFINISHED WALL. I LARGE SCALE AQUARIUM AREA PLAN 12 REF.: 02/P2.1 1/4" = 1'-0" STARTING 1/4" PER INVERT 98.50' FOOT SLOPE FD1 16 I 4. I ; r COF INVERT I j 3"W- — � 98.19' 2 V� 6 > &4. 4.N9 Ij+ P12 2"V II 3"V UP TO 3"VTR 4„W��-N.._ �' I 3 V I I FS1 . I 3„W� )4 Ul� I 12 COW- 1 /8" PER t� - --— FOOT SLOPE --- - — - II - ---T ,----4"W 4"W INVERT + 97.98' — - � I I i IF - � u r j II r � r r it _.._ I" -------- _.._.... LARGE SCALE GROOMING AREA PLAN REF.: 02/P2.1 PLUMBING KEY NOTES: Ol SHORE -LINE GROOMING TUB WITH FAUCET, STRAINER, AND BACK - FLOW PREVENTOR FURNISHED BY PETCO VENDOR. CONTRACTOR SHALL PROVIDE SUPPLY AND WASTE CONNECTIONS AS REQUIRED. CONTACT KAY STANDBRIDGE AT SHORE -LINE (877) 455-8190 X.2304 FOR ROUGH -IN INFORMATION. OBTAIN LATEST EQUIPMENT LITERATURE PRIOR TO ROUGH -IN. O2 FOREVER STAINLESS STEEL OVER -SIZE PET BATH WITH WALKING RAMP, FURNISHED BY PETCO, INSTALLED BY CONTRACTOR. RAMP ON RIGHT SIDE. BRASS AND BRONZE WORKS MODEL B-0175 FAUCET PROVIDED WITH TUB BY VENDOR. CONTRACTOR SHALL PROVIDE SUPPLY AND WASTE CONNECTIONS AS REQUIRED. CONTACT MARK ARNDT AT FOREVER STAINLESS STEEL (402) 935- 0771 FOR ROUGH -IN INFORMATION. OBTAIN LATEST EQUIPMENT LITERATURE PRIOR TO ROUGH -IN. OEXTEND COPPER TAILPIECE OF TUB OUTLET ALONG WALL (FASTENED HORIZONTALLY ALONG FRAME OF TUB), TURN TOWARD FLOOR DRAIN, TURN DOWN TO EDGE OF FLOOR DRAIN GRATE WITH AIR GAP (MAINTAINING CLEARANCE FOR HINGING FLOOR DRAIN GRATE FOR REMOVAL AND REPLACEMENT OF SEDIMENT BUCKET). SEE 18/P4.1. OTHE FLOOR IN THE TUB ROOM IS SLOPED. REFER TO ARCHITECTURAL PLANS AND COORDINATE WITH GENERAL CONTRACTOR PRIOR TO INSTALLATION OF FLOOR SINKS IN THIS AREA. O5 MOUNT HAIR INTERCEPTOR IN DRAIN PAN ON FLOOR OF CABINET NEXT TO WASHING MACHINE. INSTALL PIPING ACCORDING TO MANUFACTURER'S INSTRUCTIONS. SEE 06/P4.1. O6 CONTRACTOR SHALL BLANK OFF, CAP OR PLUG PERMANENTLY THE WASTE CONNECTION ON THIS WASTE HOSE BOX. O7 NO PLUMBING PIPING SHALL BE ROUTED OVER ELECTRICAL PANELS AND/OR CLEAR SPACE. O8 COORDINATE AND INSTALL T&P DRAIN LINE OVER TO FLOOR DRAIN. TERMINATE DRAIN OVER FLOOD RIM OF FLOOR DRAIN WITH CODE APPROVED AIR GAP. OCOORDINATE AND INSTALL VENT PIPING DOWN IN CHASE SPACE WITH ALL OTHER TRADES, PETCO AND AQUARIUM REPRESENTATIVES TO AVOID CONFLICTS BEFORE WORK BEGINS. PIPING WITHIN AQUARIUM CHASE SPACE HAS TO BE COORDINATE CLOSELY DUE TO LIMIT CLEARANCES. 10 HOSPITALITY SINK AND FAUCET FURNISHED BY PETCO VENDOR, INSTALLED BY CONTRACTOR. 11 DIMENSIONS SHOWN ARE TO CENTERLINE OF DRAIN OF FLOOR SINK/DRAIN/FUNNEL. VERIFY WITH LATEST ARCHITECTURAL FIXTURE PLAN PRIOR TO INSTALLATION. 12 A WALL CLEAN OUT IS TO BE PROVIDED IN THE TUB ROOM. UNDER NO CIRCUMSTANCES IS IT PERMISSIBLE TO USE A FLOOR CLEAN OUT. WOMEN'S 108 r� 1? 02 CLOSET 1 MEWS �_ -- 109 = _ -=i > - -- _CAGE R001 ISO ROOM t�l`r? I I �/; %,�---�--105 117 �rROOM WORK ROOM -d: 1 '� t 106 118 ,/%I / /, : ,gin ) r� GROOMING CLOSET SALON 107 BREAK RM GROOMING 12 RECEP [ION CLOSET 104 1 VESTIBULE i 11011 - ----- -- PR6-SALES j � - _-05 - -/--- - ---_- i � i 3 AQUARIUM AREA -12- 115 3• OFFICE 113 02 KEY PLAN 01 1/4" = V-0" REF.: NO SCALE PROFESSIONAL ENGINEER Duclne S. Henderson FL PE# — 46179 0 Lo tf) L r. Qo u o wo o 0 � 7 a)z o BUJ,,,<w�,�, CO U- L C) 0� 'a CV ooG� �0V)oW Uw V) s 0x JlyGr Er Ow F� UNjJM=- U � .. �w a)w .. w . 11 J m J J � C m n ZLL J W Om ❑ 0•j z Woo I- W 71 () �E WD OW0O W W❑ �� w zz ?:>LL z oU)U) s G 0 O� 00 oa =W W_ �Q N"L DISTRIBUTION: DATE: 25% REVIEW 07/19/04 75 0 REVIEW 07128/04 98% REVIEW 08/06/04 PERMIT 08/13/04 ADDENDUM #2 10/20/04 HEI JOB tl PE"rCO P.M. JOB It 0450000526 DRAWN: CHECKED: JMM DKS DRAWING TITLE: SANITARY LARGE SCALE PLANS AND DETAILS P3. 1 3/4"H 3/4"C 3/4"CW 3/4"H W 1 /2"CW & HW DOWN IN WALL I 1 2"HW Zt 3/4°CW � FT I tv 11 �+- _ i � HIGH PIPING NINSTAL ROOFLEU AS �� STRUCTURE AS POSSIBLE I , •t" mot' T I PIPING INSTALLED AS HIGH IN ROOF r STRUCTURE AS POSSIBLE _�- -n rr-I \J�--3/4 1/2"CW QWN -- IN WALL I I � . 3/4"CW UT -4 I M I _ I 1 /2"C 1 /2"F 3%4"HW , 1 /2 CW ---__ %! F/ 1 /2"H W P6 U �s -I 1 I s l�l [PING INSTALLED AT3-5 �� N IGH IN ROOF TRUCTURE AS POSSIBLE � ,.CW —1 "HW --3/4"FW— - t--+Aoq�!� �8 I rI I Y a 1 I I� I 1 /2"CW 1 /2"H W P11 - �� i �0/� 1-11 "HW U \ I c1 LARGE SCALE BACK OF HOUSE PLAN REF.: 02/P2.1 1/2"CW & HW DOWN IN `HALL /2" CW- - '2"H W 4"FW 05 1/4' = 1'-0" 20 �t- LARGE SCALE AQUARIUM AREA PLAN REF.: 02/P2.1 LARGE SCALE GROOMING AREA PLAN REF.: 02/P2.1 12 1/4" = V-0" 02 1/4" =1'-0" NOTES REF.: GENERAL PLUMBING NO -TES: 1. INSTALL WATER PIPING AS HIGH AS POSSIBLE AT/TO ROOF STRUCTURE. 2. ALL WATER PIPING UNDER SLAB SHALL BE TYPE 'K' COPPER IN ARMAFLEX. NO FITTINGS ARE PERMITTED UNDER THE SLAB. STUB UP FROM SLAB SHALL BE FITTED WITH 1/4 TURN BALL VALVE AT 12" AFF, WITH 3/4" FEMALE THREADS FOR CONNECTION BY PETCO VENDOR. 3. VERIFY ALL DIMENSIONS WITH THE PETCO VENDORS. 4. ALL DIMENSIONS ARE FROM THE INSIDE FACE OF UNFINISHED WALL. PLUMBING KEY NOTES: O1 SHORE -LINE GROOMING TUB WITH FAUCET, STRAINER, AND BACK - FLOW PREVENTER FURNISHED BY PETCO VENDOR. CONTRACTOR SHALL PROVIDE SUPPLY AND WASTE CONNECTIONS AS REQUIRED. CONTACT KAY STANDBRIDGE AT SHORE -LINE (877) 455-8190 X.2304 FOR ROUGH -IN INFORMATION. OBTAIN LATEST EQUIPMENT LITERATURE PRIOR TO ROUGH -IN. O2 FOREVER STAINLESS STEEL OVER -SIZE PET BATH WITH WALKING RAMP, FURNISHED BY PETCO, INSTALLED BY CONTRACTOR. RAMP ON RIGHT SIDE AND BRASS AND BRONZE WORKS MODEL B-0175 FAUCET BY VENDOR. CONTRACTOR SHALL PROVIDE SUPPLY AND WASTE CONNECTIONS AS REQUIRED. CONTACT MARK ARNDT AT FOREVER STAINLESS STEEL (402) 935-0771 FOR ROUGH -IN INFORMATION. OBTAIN LATEST EQUIPMENT LITERATURE PRIOR TO ROUGH -IN. O3 STUB OUT FACE OF WALL 1/2" CW AND HW ON 8" CENTERS FOR GROOMING TUB FAUCET 40" AFF. O4 STUB OUT FACE OF WALL 1/2" CW AND HW ON 8" CENTERS FOR SHORE -LINE FAUCET, 40" AFF. FAUCET AND BACK -FLOW PREVENTER PROVIDED BY PETCO VENDOR, INSTALLED BY CONTRACTOR. NO DRAIN IS REQUIRED. CONTACT KAY STANDBRIDGE AT SHORE -LINE (877) 455-8190 X.2304 FOR ROUGH -IN INFORMATION. OBTAIN LATEST EQUIPMENT LITERATURE PRIOR TO ROUGH -IN. OWASHER AND DRYER FIXTURES FURNISHED BY PETCO, INSTALLED BY CONTRACTOR. NOT USED. O7 NO PLUMBING PIPING SHALL BE ROUTED OVER ELECTRICAL PANELS AND/OR CLEAR SPACE. O8 RISE 3/4" FILTERED WATER THROUGH 1/4 TURN BALL VALVE TO CEILING SPACE. O 3/4" MIXED WATER TO FILTER. PROVIDE ALL NECESSARY ACCESSORIES. REFERENCE DETAIL 14/P4.1. 10 WATER FILTER FURNISHED AND INSTALLED BY MARINELAND RETAILER SYSTEMS (318) 747-6500. PROVIDE STUB OUTS FOR INLET AND OUTLET. SEE 14/P4.1. 11 ROUGH -IN FOR TOILET WATER SUPPLY SHALL BE AT LEAST 8" AFF TO AVOID CONFLICT WITH COVE BASE. 12 HOSPITALITY SINK FURNISHED BY PETCO VENDOR, INSTALLED BY CONTRACTOR. 13 3/4" FILTERED WATER FOR AQUARIUM MAINTENANCE. DROP TO 18" AFF IN FALSE COLUMN AND RUN ALONG TANK FIXTURE FRAMING ENSURING THAT PIPE IS SECURELY ATTACHED. STUB OUT 6" ABOVE FLOOR SINK AND PROVIDE 1/4 TURN VALVE AND 3/4" FEMALE ADAPTER. SEE DETAIL 20/P4.1 14 DROPS SHALL OCCUR IN FALSE COLUMN. LOCATE VALVES IN ACCESSIBLE LOCATION NOT BEHIND FIXTURES OR AQUARIUMS. COORDINATE AND INSTALL WATER PIPING DOWN IN FALSE COLUMN WITH ALL OTHER TRADES, PETCO AND AQUARIUM REPRESENTATIVES TO AVOID CONFLICTS BEFORE WORK BEGINS. PIPING WITHIN! FALSE COLUMN HAS TO BE COORDINATED CLOSELY DUE TO LIMIT CLEARANCES. 15 1/2" HW AND CW FROM FALSE COLUMN. RUN HORIZONTAL AND RISE TO SINK FAUCET. PROFESSIONAL ENGINEER Duane S. Henderson FL PEA — 46179 vvvmuv D 02 CLOSET 108 6, 3; 114 MEWS �L 4 109 r - (gCAGE ROOF ISO ROOM p ' ` I I ;'� 10� Ad SUB ROOM WORK Roots (' ; I - �� V/y 106 118 �;,, i /;;, ! . !� SALON INS CLOSET S 120 -Ii f — -- / / �t %_ ;,/ jj. L_- .: -.� -c� G� MING J F� RECEPTIO BREAK RM N 112 CLOSET �X' I I, I �- 104 �. %'�';�ii !� 110- � :i• �;;:',/!�:� _� ,_. _ ��_� VESTIBULE PRE SALES - 05 - __ _ 1011 116 AQUARIUM 3.? \ -moo AREA Q ,� � � I i 3• OFFICE - i , - ------�--- - --- u KEY PLAN 01 REF.: NO SCALE 0 r �, , � �owwo Iv� a F�1cn n I F-c°,-w V) E ' w Q rr) W a) wu� I O a ��_ .. C��CY N W {�q w < L'lj 0�(nLi..L00 0�N F. � NOGG V;0 WOwv) n <Zsoau>i bs-1 nTocr¢ w w rr - wxr- O oX wo- i JG�`)r w w UO --, U Z� �m w w i� CO J m LL 06 Z U) � j < W O cm ❑ �J LL - Z C Q (n Ho0 Z C) LL I�1..:D 0 LLl LLI - 0 C)_j LLI o 0 v a i-- - - LL 07 07 lV 0 �U UO C7 ww ao 'n z w� UI:irR!BUTION: DATE: 25% REVIEW 07/19/04 75% REVIEW 07/28/04 98% REVIEW 08/06/04 PERMIT 08/13/04 ADDENDUM #1 08/19/04 ADDENDUM #2 10/20/04 HEI JOB # PETCO P.M. JUB 0450000526 URLAVVN: CHECKED JMM DKS DRAWING 'nTM- WATER LARGE SCALE PLANS AND DETAILS P3.2 'ESSIONAL ENGINEER one S. Henderson FL PE# — 46179 V .101v -11, C) I0 G fi i17 /'\ U (fir/) w Q (n !� W�Mtr )W (A (�CO�W �'r•j _W N W CV to" W no�G a anV)OwC.7W(n < Y G U� .�� X r�Zt CD O F W - W G't() W xr z L'ia-x ( W L r O W r®Z vCl--Ir? .. U Z U . u0 LO L'i .. W J 1 W J ti m d � o m �ZILL C-6 j wILL Om o O� Q woo cup z U Lu w ci W D Ill O o �Co w zzm ��z n OLL,< z 0U 0 ed06 wW �i Wry DISTRIBUTION: DATE: 25% REVIEW 07/19/04 75% REVIEW 07/28/04 98% REVIEW 08/06/04 PERMIT 08/13/04 ADDENDUM #2 10/20/04 HEI JOB tt PE'UGO P.M. JOB tt 0450000526 DRAWN: CHECKED: JMM DKS DRAWING TITLE PLUMBING RISER DIAGRAMS FM LCK LCK LCK LCK LCK LCK LCK ,LCK LCK ,LCK I C I? LCK LclC E E E E E E E E E E E E E E E E E E E PANELBOARD: A FAULT CURRENT: 61,370A EQUIPMENT GROUND BUS BUS AMPS: 225A AIC RATING: 65,000A SERIES RATED MAIN SIZE/TYPE: MLO SERVES: PETCO VOLTS/PHASE: 208Y/12OV, 3PH, 4W MOUNTING: FACTORY INSTALLED SECTIONS : 1 LOCATION: PRE -SALES, ROOM :118 CKT NO. DESCRIPTION VOLTAMPS PHASE WIRE NO, BKR AMP I P I P BKR AMP I WIRE NO. VOLTAMPS PHASE DESCRIPTION CKT N0. A B C A B C 1 3 PANELBOARD CR 1,650 10 30 2 1 20 %/i%//; %j/%ice SPARE 2 j% / 800 /f /j' / 1 20 12 / %f / 500 ;;/ ;/ BIRD RECEPT (EMP) 4 5 7 CHECK COUNTER RECEPT CHECK COUNTER RECEPT j!/ /; / 360 ; ;,�,/ ;;/// 360 %//ij 10 10 20 20 1 1 1 1 20 20 12 10 '// ;; 720 ///; ' //; 250 /; DOCK LIGHT (EMP WINDOW RECEPT 6 8 9 CHECK COUNTER RECEPT // /j/i 360 10 20 1 1 20 10 /� 1,920 / //%i END CAP DISPLAY (CUST) 10 11 CHECK COUNTER RECEPT %1111, /r/ 360 10 20 1 1 20 10 , // /� /,% 1,920 END CAP DISPLAY (CUST) 12 13 _ SPARE ' i / ,,�,,; / ; /,�; 20 1 1 20 10 1,920 //% ,; / ; / END CAP DISPLAY (CUST) 14 15 AVIARY TRANSMITTER RECEPT ;.i -'%; 180 /,!'j;;�j 12 20 1 1 20 10 1,9207,/7/7/7/END CAP DISPLAY (CUST) 16 17 OFFICE RECEPT ,,/,i/,��j /i/ i 360 12 20 1 1 20 10//,/i ;; /;i 1,920 END CAP DISPLAY (CUST) 18 19 OFFICE RECEPT 360 ,// / % / j'; 12 20 1 1 20 / ,% / , SPARE 20 21 PRE -SALES RECEPT ;;, j/; 360 /fj 12 20 1 1 20 / // SPARE 22 23 FIRE ALARM %/ % /; ; ' 300 12 20 1 1 20 12 / ; / , ///' 200 QUICK TAG (EMP) 24 25 SPARE %/��, / / /j/ ,; 20 1 1 20 12 500 ///// , // ,/ SODA COOLER 26 27 SOUND SYSTEM j; %/jj/ 200 %%//,-j/ 12 20 1 1 20 12 _ �, //;/ 100 j'/;' DOOR BUZZER 28 29 EMS-1 j//ij ,' f 200 12 20 1 1 20 12 / ,'/ // • ;� /, / 300 EWC (EMP) 30 31 EMS-2 200 %i/, / /,!, 12 20 1 1 20 12 720 j! /j , i ,SALES / j/j / MISC RECEPT 32 33 TURTLE DISPLAY %/// 360 ~Tf% /'/,/ ; 12 20 1 _ 1 20 12 / ,, 360-%//%l �/ K E E T P E T T E R 34 35 MAIN 'TELCO TERM BOARD ;;//„'/,- ///;,�' ; 500 12 20 1 _ 1 20 / / ; , //, SPARE 36 37 SECURITY SYSTEM 200 / // / %%/�/;�� 12 20 1 1 20 12 1,356 / . ,/ /: // TANK DISPLAY 38 9 41 K I I L Y BURGLAR ALARM PANEL ///, /% i% ////i 6 '%f/� i ////ii'i� 180 1 12 20 1 1 1 0 20 1 12 �/ 'j// /,i 6 '/, / ,� ! /.': 180 T D P A POWER PANEL 4 2 SUBTOTAL 2,770 2,620 2,260 1 216 1 6,156 1 4,770 1 SUBTOTAL TOTAL PHASE A - VA AMPS TOTAL PHASE B - VA _ AMPS TOTAL PHASE C - VA AMPS TOTAL PANEL - VA 7,986 LOAD CONN, VA DF LOAD CONN. VA DF GF-GND FAULT CKT INTERRUPT E - EMS CONTROLLED CIRCUIT LCK - LOCKABLE TAB 67 COOLING 1.00 REFRIGERATION 1.00 8,776 HEATING - 1.00 DISPLAY CASE 1.25 73 _ LIGHTING 250� 1.25 KITCHEN _ 1.00 7,030 _ _ GEN. RECEP_ TS_ �_- 21,092 1.0/.5-� TOTAL DEMAND VA 1 24,584 AMPS-1 68 59 MOTOR_S 1.00_ 23,792 SUPP. HEAT _ 1.00 AMPS 66 _ IMISC EQUIPy _ 0.50 PANELBOARD: B FAULT CURRENT: 61,370A EQUIPMENT GROUND BUS BUS AMPS: 225A AIC RATING: 65,000A SERIES RATED MAIN SIZE/TYPE: MLO SERVES: PETCO VOLTS/PHASE: 208Y/12OV, 3PH, 4W MOUNTING: FACTORY INSTALLED SECTIONS : 1 LOCATION: PRE -SALES AREA, ROOM :118 CKT N0. DESCRIPTION VOLTAMPS PHASE WIRE N0. I BKR AMP JPJ P I BKR AMP I WIRE NO.1 I VOLTAMPS PHASE ::J_DESCRIPTION CKT INO. A B C__l A I B I 1 SHUNT TRIP POWER/ 12 20 1 1 20 12 100 SMOKE DETECTOR 2 3 EF-1 (EMP) 696 12 15 1 3 20 /, /,�// //, /; SPARE 4 5 EF-2 /� !///�/ 696 12 15 1 ; / / / / / // 6 7 _ EF-3 528 �%% // ; �! / 12 15 1 ////.' ifi/f i 8 9 11 EF-4 (EMP) EF-5i , ; ' /i 528 ,/i//% j/i' / / 528 12 12 15 15 1 1 2 15 12 //, /� 750 /j, /f /CUH-2 10 12 % /i�/ i/� 750 13 15 EF-6 EF-7 696 //; /i ,/��// 528 r%// '//, /; ,. 12 12 15 20 1 1 1 1 20 20 10 1,200 , ,//, / �/ /,� / •//,/ / ;/// / / EXTERIOR SIGNS SPARE (SIGN) 14 16 17 SPARE 20 1 1 20 /!i' // %//; SPARE (SIGN) 18 19 RTU RECEPT 720 ;i/,, / j/ 12 20 1 2 _ 1 20 20 12 1,500 , / %%i /// // CUH-1 SPARE 20 22 24 21 23 SPARE SPACE ONLY/�; j. , L' %i,'%/ ii; ii / 20 20 1 1 /; // /j // 1,500 // /i / , 25 SPACE ONLY %' j ;� j;'%/ / 1 1 20 10 1,320 /// // ,/ AQUARIUM LIGHTS 26 27 SPACE ONLY �; jj/ %�i%'' 1 1 20 10 ' j ,/// 1,320 , / // AQUARIUM LIGHTS 28 29 AUTOMATIC DOOR 1,200 12 20 1 1 20 10 / / j// 1,320 AQUARIUM LIGHTS 30 31 AUTOMATIC DOOR 1,200 /,/,f� % %/i; 12 20 1 1 20 10 1,320 '// ; ' / / AQUARIUM LIGHTS 32 33 AUTOMATIC DOOR //' /i 1,200 j' / j 12 20 1 1 /// j/ /, /SPACE ONLY 34 35 SMALL ANIMAL POWER (EMP) 660 12 20 1 1 SPACE ONLY 36 37 SMALL ANIMAL POWER (EMP) 660 / ji; 12 20 1 1 , // / // /SPACE ONLY 38 39 SMALL ANIMAL POWER (EMP) ' i�!,�% 660 i / // ; 12 20 1 1 , / /SPACE ONLY 40 41 SMALL ANIMAL POWER EMP i/,/%;/i ; //i, 660 12 20 1 1 f/// , / //i SPACE ONLY 42 SUBTOTAL 1 3,804 1 3,612 1 3,744 1 1 5,440 1 37570 2,070 TOTAL PHASE A - VA AMPS TOTAL PHASE B - VA 9,244 LOAD CONN. VA DF LOAD CONN. VA DF GF-CND FAULT CKT INTERRUPT 2 E - E S C L D CI C IT LCK - LOCKABLE "TAB 77 COOLING 1.00 REFRIGERATION 1.00 7,182 1.00 CASE _ 1.25 AMPS TOTAL PHASE C - VA 60 _HEATING _LIGHTING _ - 6,_480 1.25 _DISPLAY KITCHEN _ 1.00 - 5,814 GEN. _ 7,060� - TOTAL DEMAND VA 23,860 1 AMPS 66 AMPS TOTAL PANEL - VA 48 _RECEPTS MOTORS _1.0_5 4,200 - 1.00 22,240 __ _ SUPP._HEAT 4,_500 u 1.00_ AMPS 62 ­MISC 0.50 E, GF E E E E E E E E E E E GF,LCK LL CK LCK E E E 2 G ,E GF,E GF, E GF, E PANELBOARD: L FAULT CURRENT: 60,581A EQUIPMENT GROUND BUS BUS AMPS: 225A AIC RATING: 65,000A SERIES RATED MAIN SIZE/TYPE: MLO SERVES: PETCO VOLTS/PHASE: 208Y/120V, 3PH, 4W MOUNTING: FACTORY INSTALLED SECTIONS : 1 LOCATION: PRE -SALES, ROOM :118 CKT NO, DESCRIPTION VOLTAMPS PHASE WIRE N0. BKR AMP P P BKR AMP WIRE N0. VOLTAMPS PHASE DESCRIPTION CKT NO. A B C A B C 1 NITEZEMERG/EXIT LIGHTS 500 %/fj%/ %�/ �:' 12 20 1 1 20 12P780E%/%'%/j %%////'� GROOMING LIGHTS/EMERG (CUST) 2 3 NITE EMERG/EXIT LIGHTS !i; j%/// 500 j; j%j; 12 20 1 1 20 12 360 ' / / BIRD/SUPPLY LIGHTS EMP) 4 5 SALES LIGHTS (STTOCK) %j//%/' /� / / 720 12 20 1 1 20 12 / /;/ 600 PRE -SALES LIGHTS EMERG (EMP) 6 7 SALES LIGHTS (CUST) 660 ' ' //./,�, ' '/' i,; / 12 20 1 1 20 12 / ,/,/ ' , ,/ WALL PACKS 8 9 SALES LIGHTS (STOCK) //' j// 600 12 20 1 _ 1 20 12 / 240 // ; RR/CORR/EMERG LIGHTS (EMP) 10 11 SALES LIGHTS (CUST) ' /; // / „'// 600 12 20 1 1 20 12 /_//i/ / / / ,/ 120 OFFICE LIGHTS (EMP) 12 13 SALES LIGHTS (STOCK) 1,020 % / / j 12 20 1 1 20 12 120 / /i // BREAK ROOM LIGHTS EMP 14 15 SALES LIGHTS CUST 'i//i 1,020 12 20 1 1 20 / / f/ ,; SPARE EMP 16 17 SALES LIGHTS (STOCK) j ; 540 12 20 1 1 20 ; j ; 'j / / SPARE (EMP) 18 19 SALES LIGHTS CUST 660 jj//j , / /// 12 20 1 1 20 SPARE (STOCK) 20 21 SALES LIGHTS STOCK ///, 9UU / ;, // 12 20 1 1 20 12 %/f/, ; 342 %/f /LIGHTS ADOPTION (CUST) 22 23 SALES LIGHTS (CUST) 717 /? /i' /j 780 12 20 1 1 20 i / f/ SPARE STOCK 24 25 SALES LIGHTS (STOCK) 600 !j / 12 20 1 1 / // / //i SPACE ONLY 26 27 29 SALES LIGHTS (OUST) SALES LIGHTS (STOCK) ,/f% / ; % /, / 600 j / / %/'; 960 12 12 20 20 1 1 1 1 20 20 12 / / 7 / ,/ / // j ,/ j 1,179 SPARE HID LIGHTING 28 30 31 SALES LIGHTS (CUST) 840 / j; / /„/ , 12 20 1 1 20 12 1,179 //' / , / / HID LIGHTING 32 33 SALES LIGHTS (STOCK) ;; /// 480 ?% / 12 20 1 1 20 12 ' // // 1,179 // /HID LIGHTING 34 35 SALES LIGHTS (CUST)/%;; /// 540 12 20 1 1 20 12 1,179 HID LIGHTING 36 37 SALES LIGHTS (STOCK) 120 ' / / //" /j / 12 20 1 1 20 , / / ; / / SPARE 38 39 SPARE / / // j/ //„ 20 1 1 20 %� j /; SPARE 40 41 VESTIBULE LIGHTS CUST /%/, /%� 192 12 20 1 1 20 /� / / SPARE 42 SUBTOTAL 1 4,400 1 4,100 1 4,332 1 1 2,459 1 2,121 1 3,078 1 SUBTOTAL TOTAL PHASE A - VA AMPS TOTAL PHASE B - VA AMPS TOTAL PHASE C - VA 6,859 LOAD CONN, VA DF LOAD CONN. VA DF E - EMS CONTROLLED CIRCUIT LCK - LOCKABLE TAB EX - EXISTING CONDUIT AND CONDUCTORS TO REMAIN. EXTEND AS REQUIRED. 57 COOLING 1,00 REFRIGERATION 1.00 6,221 _HEATING 1.00 DISPLAY CASE 1.25 52 LIGHTING _- 20,490 1.25 KITCHEN_ 1.00 7,410 GEN. RECE_PTS MOTORSY SUPP.�HEAT _ 1.0L5 1.00 1.00 -�� TOTAL DEMAND VA 25,613 1 AMPS 71 AMPS TOTAL PANEL - VA AMPS 62 20,490 57 MISC EQUIP -- M 0.50 E E E E E E E E E E E E E 2 E E E E E E E PANELBOARD: MDP FAULT CURRENT: 63,786A EQUIPMENT GROUND BUS BUS AMPS: 800A )� AIC RATING: 65,000A FULLY RATED MAINT `S►ZE/TYPE: '-MLO SERVES: PETCO VOLTS/PHASE: 208Y/12OV, 3PH, 4W MOUNTING: SURFACE SECTIONS : 1 LOCATION: PRE -SALES, ROOM :118 SERVICE ENTRANCE RATED CKT NO. DESCRIPTION VOLTAMPS PHASE WIRE NO. BKR AMP P P BKR AMP WIRE NO, VOL TAMPS/PHASE DESCRIPTION CKT NO. A B C A B C 1 3 5 PANELBOARD A, B & CR 17,230 'j �� %%/j/ MF 225 3 3 150 MF 6,859 ;%" ij�j' ' % �% PANELBOARD L _ 2 j/ /� 15,958 ;'.// , ; / // 6,221 ilT� %. 4 f//_12,844 7,419_ _6 7 PANELBOARD G 4,188 !/ /; 2 125 3 3 110 1 8,820 % /,// %%'%!j RTU-3 1\ ` ` 8 9 j / / 5,628 '' // / L //// 8,820 // //; 10 11 'f /%//i'f/// :/ 5,388 �, '///// 8,820 12 13 15 PANELBOARD AQ 10,957 ;%, /%f ; %,/ 8,560 // / , / /,%/ _ SL .�-,. 125 ,r `.., 3 _ 3 110 1 8,820 RTU-4 14 ;; jj/ 8,820 T!,,!///r 16 -.1.0, 537� ii /// f//,- ; j 8, 820 18 19 RTU-1 �\ �, _ - 8,820 / i / / , 1 110 , _ 3 _ 3 80 3 5,940 '/� i RTU-5 20 21 23 ; ' // 8,820 'J/j j,% % 5 940 ''/�� / 22 ;/iii '. i T f�%%i' 8,820 %/,/iii% f///% / 5,940 24 25 27 RTU-2 8,82U //f% / /i / i"'' �, , iT �r'i 1 11 U - ' 3 '_ _ 1 20 '�-r., ' , %%i , /, i SPA 26 //i/, ;ii 8,82U 7///,!/i 1 20 ; %, /; ; ;i, /,• /SPARE 28 29 1,%'.;' _fT'�! 8,�,20, 1 20 %/T%%% j i/ f SPARE 30 31 33 35 VWT 50/ ; i j / 12 20 3 1 ; % �� /;,! SPACE ONLY 32 '/j ! j ; 50 '/,'j / 1 %/ ;/j/ j SPACE ONLY 34 50 1 --.� .,., , :/7, , /' ' Gj -..' ✓.✓ SPADE ONL - �..r v ,- .;- .i ✓-; 36., 37 WATER HEATER 2,300 ; / ,!/; i /; // 6 45 3 3 60 4 2,880 //;/ WATER HEATER 1 38, 39 ; %�,// 4,000 ' , j! j ;/ j% / 4,992 40, 41 //% iii i'%f,�;/i 2,300 •/ ///; ,//// 2,8,80 42, SUBTOTAL 52,365 1 51,836 1 48,759 33,319 1 34,793 33,870 1 SUBTOTAL TOTAL PHASE A - VA 85,684 LOAD CONN. VA DF LOAD CONN. VA DF SL - REFER TO SINGLE -LINE DIAGRAM MF - BY MANUFACTURER AMPS 714 COOLING 1.00 REFRIGERATION 1.00_ TOTAL PHASE B - VA AMPS 86,629 HEATING _ ___ _ 123,660 _ 1.00 _ DISPLAY CASE 1.25 KITCHEN 1.00 TOTAL DEMAND VA 235,017 AMPS 652 722 LIGHTING _ GEN. RECEPTS___^ MOTORSS-_ SUPP. HEAT MISC EQUIP __ _ 150___1_0�_5 _ 19,352 _ 1.2_5 1.00 .OQ 1.0c).50 101 .50 TOTAL PHASE C - VA 82,629 AMPS TOTAL PANEL - VA 689 254,942 AMPS 708 PANELBOARD SCHEDULES 02 REF.: NO SCALE NOTES FOR THIS DRAWING AND E1.26 1. PAY PARTICULAR ATTENTION TO PANELBOARD CIRCUIT DESIGNATIONS. CIRCUITS ARE TAGGED AS FOLLOWS: GF) = GFCI CIRCUIT BREAKER LCK) = LOCK ON DEVICE (E) = ENERGY MANAGEMENT SYSTEM (EMS) CONTROLLED CIRCUIT (TS) = CIRCUIT CONTROLLED THROUGH CONTACTOR AND TIMER. SEE KEY NOTE #2 E3.2. EXAMPLE "POWER OUTLET/BAGGING" (GF, LCK) REQUIRES A GFCI CIRCUIT BREAKER WITH A LOCK -ON DEVICE. 2. ROOFTOP UNIT CIRCUIT BREAKERS SHALL BE HACR RATED. 3. CIRCUIT BREAKERS FOR FLOOR RECEPTACLES SHALL BE GFCI PROTECTED. 4. WIRE SIZE OF BRANCH CIRCUITS SHALL BE MINIMUM #12 AWG, BUT NO LESS THAN PERMITTED BY THE NATIONAL ELECTRICAL CODE (NEC) FOR SPECIFIED OVERCURRENT PROTECTION, ANY DISCREPANCY MUST BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO BID. 5. USE THE BUILDING INTERIOR AND EXTERIOR LIGHTING TO BALANCE THE LOADS ON THE SYSTEM. RELOCATE LOADS STAYING WITHIN SIMILAR BUILDING FUNCTIONS. SEE INTEGRATED POWER AND CONTROL ASSEMBLY SHOP DRAWINGS FOR BUILDING FUNCTIONS. 6. CONNECT FIRE ALARM SYSTEM AND FIRE SUPPRESSION SYSTEM ALARM DEVICES TO A#23. 7. ALL LOADS CIRCUITED TO PANELBOARD 'CR' SHALL BE ISOLATED GROUND 8. SOME CIRCUITS ARE NEEDED FOR SERVING THE FOLLOWING ENERGY MANAGEMENT SYSTEM FUNCTIONS: EMP) = EMPLOYEE STOCK) = STOCK CUST) = CUSTOMER (GROOM) = GROOMING 9. REFER TO INTEGRATED POWER & CONTROL ASSEMBLY SHOP DRAWINGS FOR DETAILS REGARDING ASSEMBLING, HANDLING, MOUNTING, FASTENING, & SUPPORTING THE ASSEMBLY, AND MAKING LINE VOLTAGE AND LOW VOLTAGE WIRING CONNECTIONS. 10. FAULT CURRENT ASSUMPTIONS: AFC=65,000A AT SERVICE ENTRANCE EQUIPMENT. 7m li --t I J -`t 11 -V I CABINET WEIGHTS FULLY INTEGRATED - - - 1100 LBS NOTE: REFER TO HILL PHOENIX SHOP DRAWINGS FOR INSTALLATION AND MOUNTING DETAILS. INTEGRATED ASSEMBLY ELEVATION REF.: 06 NO SCALE PROFESSIONAL ENGINEER Craig R. Lanham FL PE# - 48650 BUILDING ELECTRICAL SERVICE LOAD SUMMARY BUILDING OCCUPANCY TYPE: M BUILDING SQUARE FOOTAGE: 15,000 SERVICE DESCRIPTION: 208Y/120V, 3PH, 4W LOAD DESCRIPTION Connected KVA Demand I FACTOR Demand KVA HVAC - SUMMER 0.00 100% 0.00 HVAC - WINTER 123.66 100% 123.66 LIGHTING 25.64 125% 32.05 RECEPTACLES 75.65 100%; 50% 42.83 MOTOR LOADS 4.20 100% 4.20 SUPPLEMENTAL ELECTRIC HEAT 23.85 23.85 MISCELLANEOUS EQUIPMENT 0.00 50% 0.00 COMPUTER LOADS 0.00 100% 0.00 EXTERIOR LIGHTING 1.58 125% 1.98 TOTAL LOAD 254.58 KVA 236.06 TOTAL AMPACITY 706.65 AMPS 655.24 SERVICE AMPACITY 800 AMPS 800.00 SPARE CAPACITY 93 AMPS 145 SHOW WINUUW / TRACK LIGHTING DEMAND ADDED LOAD SUMMARY REF.: 01 NO SCALE � ' 3,1IG'c i (D U r� I o (D O V O wCV) u)�c�D 1rw ca Lu w wU-) 5i-L o WNW NON �2,- ®� � �oozo V) O w O w V) ;<1 ") 8 tz Lj w ''n w cr g./ ®w'��s owx j uW O W W W rI O NJrS U 'Zr�) w v)m w W J w m .J J J m 2EZ LL Z0 �� w 0 -Mj ❑ - � Z C� a- Q cn i-- 0 _ j z 0 LL W W❑ W:D 0 W_j 00 Z Z I CI) w LL :E • Z tt O ld OV O O 9L '-OC 0 WW 1r Cl ur N �. DISTRIBUTION: DATE: 25% REVIEW 07/19/04 75 0 REVIEW 07/28/04 98% REVIEW 08/06/04 PERMIT 08/13/04 ADDENDUM #1 08/19/04 ADDENDUM #2 10/20/04 HE[ JOB d PETCO P.M. JOB # 0450000526 DRAWN: CHECKED: ALR BJT DRAWING TITLE i PANELBOARD SCHEDULES E1.2A -ESSIONAL ENGINEER .raig R. Lanham FL PE# — 40650 U 0 -r j' o co o r• U owAl o I-- w I w � �r ►-�+w_ ��w�m� 0,f) V) W W w 0-4 �yl 1 7z- U ¢C2 Fir W tt) W I L>r IL 4 JL' O`er w"),- �W O ( ` _ 41���Jr75 LO U7 CD U f� W W J W F- W J J Q C1l IL UJ LL] O m o ....t... ILL OY Z E r®-j Q boo WD ® WW❑ uio0 �U7 w�>z ZZ tV ed Q Qo 00 ILor LT C7 wW p � Z tV Q O U] DISTRIBUTION: DATE: 25% REVIEW 07/19/04 75% REVIEW 07/28/04 98% REVIEW 08/06/04 PERMIT 08/13/04 ADDENDUM #1 08/19/04 ADDENDUM #2 10/20/04 FIE[ JOB # PETCO P.M. JOB it 0450000526 F2AWN: CHECKED: ALR L BJT DRAWING TITLE PANELBOARD SCHEDULES E1.2B i ! I__ f I I I I IL <J 4� 'Il I I ' I { 1 I I I 1 1 I I V I t I lI I .1 10 -M 3. _ EM1- I---- X1 3� 1 10-- 43 27 C � FM 125 -1 S®10�_ -� ,4` I1- I 27 1 lLlllusyu. C� L 10 1 EM1 � 6 X1 I K I 6 r__ A-4- A _r \µlw.4 27 - I� I II Y I fi i - A II fl Y 6 10 25 _ A 29 31 h. -.._ 27 14 EM Y _ _ I rl 13 27 — t Y EM4� I _— 25 l _J L 1 6 7 21 23 13 29 1 31 29 31 29 31 29 31 RIBA �4II 1 �� K 1 I K 17 � K 1 i K -I 1 K_ _-I 19 _K 17 19 I I,I ��'�� I __ - ---- •---� —I = -- - =-� - --_-= _lam � r='=-��� ------------ 19 MH250 / ��� 19 34 ,' ,. GLO 1 MH23,- MH250 2 I '• `���� 34 \ ® MH250 MH20 AM 3"�X \ 34 ( s, EM I \®X ��� -- _ 3 I M nKBP KB B. E KB �T-� KB �EM� / :\ iM 33 35 F_ 1 ® 34 K 250 it : J w 35- 33 -- -- 35 - — 32 250 E_ I 33 I KB 33 35 KB - 35 _ ® 34 250 0 � o I '.,K ram. I -- 35 1 X 0 KBE K iq� l i 'I �' �i.� KB KB 33 35 KB /[� -----� r MH250 KB E KB - `, 30 `�.4 ) 3� KB KB KB / M®50 30 21 ''w. MH250 I®I3 )® 30 11 K I I I IH =11K- 71 9] 1 11 1 11 5 21 33 ' 35 33 35 33 36 250 �® X I ® ��36250 L__/9 J 30 250 R F-T-1'— F=dm A fl= IKI I I IN K 1 / 'A --- 7 - 5 9 - M LL _ - (� ; 9 23� 2�123 � 21 _ 23._ 3 NOTES GENERAL ELECTRICAL NOTES: 1. ALL LIGHT FIXTURES TO BE CONNECTED TO PANELBOARD 'L' UNLESS OTHERWISE NOTED. 2. ALL LIGHTING FIXTURES IN SALES AREA CONTROLLED THROUGH EMS LIGHTING CONTROL SYSTEM. 3. EMERGENCY EGRESS LIGHTS SHALL BE CIRCUITED TO THE NEAREST NIGHT LIGHT FIXTURE EXCEPT WHERE OTHERWISE NOTED. 4. CONNECT SWITCHES AND BRANCH CIRCUITS TO OUTLETS, EQUIPMENT AND LIGHTING FIXTURES AS INDICATED ON PLANS AND PANELBOARD r SCHEDULES WITH #12 MINIMUM CONDUCTORS IN CONCEALED RACEWAYS. CONDUCTOR SIZES AND QUANTITIES OTHER THAN #12 'A l � AWG SHALL BE AS NOTED. ALL FINAL CONNECTIONS TO 1= I TRANSFORMERS, MOTORIZED AND VIBRATING EQUIPMENT SHALL BE WITH FLEXIBLE METAL CONDUIT. I 5, SEE SHEET E2.2 FOR LOCATION OF EXHAUST FANS. - - -- - --_-- - II - 6. ALL DIMENSIONS ARE FROM INSIDE FACE OF UNFINISHED WALL. 7. MOUNT ALL EMERGENCY LIGHTING AT 14'-0" AFF EXCEPT WHERE NOTED. 8. CEILING MOUNTED OCCUPANCY SENSOR SHALL CONTROL LIGHTING IN ,'^ I ROOMS IDENTIFIED EXCEPT NIGHT LIGHTING. COORDINATE WITH ALL O'(HER A TRADES BEFORE FINAL PLACEMENT. SET TIME DELAY FOR ALL CEILING 2 lr� .--n I I SENSORS AT 15 MINUTES. ELECTRICAL KEY NOTES: - ---- I I 1 JUNCTION BOX FOR SIGN. VERIFY LOCATION AND CONNECTIONS IN FIELD. A W _- ❑ SIGNS CONTROLLED THROUGH NIC EMS. THE CONTRACTOR SHALL PROVIDE W --- -_-- 2 - --- 2� ' MATERIALS AND FINAL ELECTRICAL CONNECTIONS FROM THE POINT OF I� -''t I ROUGH WIRING AND STUB -OUT AT THE INTERIOR FACE OF THE EXTERIOR _ A S2 -� , ' I ! ❑2 THIS ROOM WILL HAVE BATT INSULATION IN CEILING. MAINTAIN J W - W d ADEQUATE CLEARANCE FOR LIGHT FIXTURE INSTALLATION. 7'-0' 2 _ AFF ___. __ _ _-- -� - 22 6n 3 NOT USED. NOT USED. PROVIDE LIGHT SENSOR FOR VESTIBULE NORMAL LIGHTING. 2 2 _I I © CONNECT THIS EMERGENCY FIXTURE TO THE CIRCUIT BREAKER FEEDING THE LIGHTING ��•._ _ I I , I MOTION SFIXTURES ENSORCONITROLLINGTHE LIGHTING. S ROOM iD OCONTACTOR AND THIS CONTACTOR LOCATED IN THE CONTROL PANEL IS IN ADDITION TO THE MOTION _ SENSOF CONTR L. 1 22 2--2-- A 2 (1 I 7 NOT USED. 131} �- i - 8 OUTLET FOR DOCK LIGHT TO BE GRAY IN COLOR. \ Y Y ❑9 PENDANT MOUNT EMERGENCY FIXTURE AT LOCATION SHOWN. ROUTE 1" A I I CONDUIT FROM METAL TRUSS ABOVE DOWN TO JUNCTION BOX AT 14'-0" AFF. r- - 4 I I I I PROVIDE LATERAL SUPPORT AS REQUIRED PER LOCAL BUILDING CODE. �L-_..j �- ----� I I I 10 CONNECT TO EXTERIOR LIGHTING CIRCUIT SERVING SAME GENERAL EXTERIOR AREA UNLESS OTHERWISE NOTED. CIRCUIT WITH UNSWITCHED HOT AHEAD OF r-- LIGHTING CONTROLS. >0 I - A MH250 X1 SLR q�X1I I I 6 3 B# I i I� I AE 4 EMI 3 I .-1 4 BAR JOIST -\� STRUCTURAL BEAM IN BACKGROUND 1 �3 .I 10 BEAM CLAMP X1 I I i (TYPICAL) UNISTRUT = -_ _ =C. 11 - G 1°11 j I I JUNCTION BOX i i Y Y Y I I HANGER-, WITH EMT ` /A/4"RIGID MC CABLE WITH 1,1, SLACK (WHEN CONDUIT 11 �- ALLOWED) NOT TO g 1J� r 9 - I - — -_-ail EXCEED 6'-0" OF - — UNSUPPORTED E - LENGTH. FLUORESCENT FIXTURE IEEE - --- I MOUNTING HEIGHT AS INDICATED ON THE FIXTURE SCHEDULE ON SHEET E1.1 11 - 9� -- 11 I KEY NOTES (SYMBOL,OO 2, ETC.) 1. FASTEN UNISTRUT #P1000T CHANNEL TO BOTTOM RAIL OF BAR JOIST WITH Y Y Y I 3/8"-16 X 1-1/4" SCREWS, HEX NUTS, WASHERS, AND LOCK WASHERS, _ OR USE 1/2" RIGID CONDUIT FASTENED WITH C-CLAMPS FOR FLUORESCENT S IN K RO M AREAS J•, �•-.�\ �- - �--� VIA I•URE BAC 0 a-- 2 —-�' - - I 2. #12 STEEL CHAIN OR #2 CRIPPLE FASTENER 3. PROVIDE SEISMIC RESTRAINTS WHERE REQUIRED. ---- --? ---- - 2-1 ------23---- �- - I LIGHTING FIXTURE MOUNTING DETAIL 06 -I� L REF.: NO SCALE —_ tl 5 WOMEN'S CLOSE( 108 Q 61 PROFESSIONAL ENGINEER Craig R. Lanham FL PE# — 48650 J _J V- G --� oZS LEI 0 Eno ®� L_.1. or- Z E 0CL < (n F-- 0 -A zc)L QUW0 W� �C� 0 W �°0 :5z OU)W 0 0 a 00 • �U od w W mo Ql z UISTRIBUNON: UAFE: 25% REVIEW 07/19/04 750 REVIEW 07/28/04 98% REVIEW 08/06/04 PERMIT 08/13/04 ADDENDUM #2 10/20/04 MEN S I -.-. �DCAGE ROOV 109 1U5 � ISO ROOM � � _- `---- i----------- I �!-�, ��-C}- 117 }t.> I / \ Nj I (UB ROOM WORK ROOM i�I _ I -- I i A , 106 I GROOMING ! ,L ,_ I ��i 1 l - SALON CLOSET GROOMING 112 I RECEPTION �� 104 HEI JOB tt PETCO P.M. JOB 11 CLOSET -, ! VESTIBULE 110 j _ - -_ -- _- - c 101 0450000526 PRE -SALES DRAWN: CHECKED: 116 II I .� 1 I AQUARIUM ALR BJT OFFICE 113 DRAWING TITLE: FN A ELECTRICAL LIGHTING PLAN ELECTRICAL LIGHTING PLAN 02 KEY PLAN 01 REF.: 1/8" = 1'-0" REF.: NO SCALE E2. 1 Lo r L ... L I f-- r- f II II I II (i1 5'-2 1' jL1I[[1_I{11D.Jj l�.�tl�l�+ ---- 6,-1„ L) I f o 10'-0" o QO I 0 13'-11" CB-], A L f-- - : �/ I 8' 5'k, ao o - `• _-- in q�p� in N. i Y r� 0� r-,—J 1 4--9„ 8'-9" 12'-0"� - I �'-6" 10'-0" L.J 5'-6" �_ i w J-1 I - 2Lp i, ELECTRICAL LIGHTING PLAN REF.: NOTES I REF.: NOTES FOR THIS DRAWING ALL DIMENSIONS ARE FROM FACE OF UNFINISHED WALL. REFER TO ELEVATIONS FOR EXTERIOR LIGHTING PLACEMENT. FIXTURES NOT IN CEILING GRID AND NOT DIMENSIONED SHALL BE FIELD VERIFIED WITH PETCO PM PRIOR TO INSTALLATION. WOMEN'S 108 MEWS 109 ISO ROOM 117 WORK ROOK 11a CLOSET 120 BREAK RM 112 CLOSET 110 PRE -SALES 02 KEY PLAN 1/8" = V-0" REF.: PROFESSIONAL ENGINEER Craig R. Lanham FL PE# - 4.8650 d' o n W G CD u;� �y V)`r ..CJ�wm ® CY V 25 V) p W O W V) J W p r W W .. W w w .-I d J Cp L— •— 06 QW 0m o ®� LL Q�oo �ZR � � U) Z () F—a- I wWD W:D O WUO Z ��^^ �v! z 0 ?:>Z OU)U) tV C1) 3 "L !r O 0U •� ed � OW 9LXo W VQ Ul DISTRIBUTION: WE 25% REVIEW 07/19/04 75% REVIEW 07/28/04 98% REVIEW 08/06/04 PERMIT 08/13/04 ADDENDUM #2 10/20/04 I 1 iI IIU")l TUB ROOM %/ ,._ 106 GROOMING SALON 107 GROOMING / I `----. -- RECEPTION I , j k 1()� HEI JOB It PETCO P.M. JOB It VESTIBULE 101 0450000526 AQUARIUM DRAWN: CHECKED: AREA ALR BJT • / � � ✓ f J ' � OFFICE - 01131 DRAWNG TITLE ELECTRICAL LIGHTING DIMENSIONAL PLAN 01 NO SCALE E2. 10 .� F�� CF - D i I I 1 I r7--_f i I i ` I, AQ 2 /jB#9 EF)11 4 <" 18 i Ir JL 47— I I r CU ` I I _M l I I 11 M6P#14,16,18, � U�I �200 3' J10 I _ / / 19,NEMA 3R /\ 1 I 7—1 Al � ��I� { EFrr __ ram: I I 7 8 I; RTU L.� 2217 f 1 1 I 1 �F 3 ! ---I 1❑3 f I _- -- ---- J/ 05 I -�� I I I " ill t _ � J TYP 2219 I { I I 2217 MDP11 \ 200%3/ 02 FIEMg; 3R[ A#39 L. A'# 32 :.::............... . F4 it .KI1I�-UUS.SIJA1ALu+�+-—. ( A#21 5 LA 6 E3 A#15'\ ' 10'-0" AFF 3 A#35 A#37MDP 10 od II— _F I �pI A# I 32I II I l� NOTES PROFESS I ONAI_ ENG I NEER REF.: Craig R . Lanham FL PE# — GENERAL ELECTRICAL NOTES: 48650 1. SEE LARGE SCALE PLANS FOR DETAILS OF THOSE AREAS. 2. SEE 20/E3.2 FOR ACCUSTAT WIRING DIAGRAM FOR CUH-1. 3. LOCATE SENSOR JUNCTION BOXES AT 6'-0" AFF IN RETAIL, ALL OTHERS AT 5'-0" AFF EXCEPT WHERE SPECIFICALLY NOTED OTHERWISE. 4. ALL DEVICES NOT SPECIFICALLY DIMENSIONED MAY BE LOCATED I /- 8" IN EITHER DIRECTION IN PLAN FROM THEIR APPROPRIATE LOCATION (Z l SHOWN (TO NEAREST STUD OR NEAREST CMU CORE). ALL DIMENSIONS r/ ARE FROM INSIDE FACE OF UNFINISHED WALL. 5. VERIFY LOCATION OF ALL DEVICES, POWER POLES, ETC., WITH LATEST FIXTURE PLAN. 6. INSTALLATION OF ELECTRIC PANELBOARDS SHALL BE IN - -`_ - __ ACCORDANCE WITH LOCAL CODES ---------- - r1 I �I !� 7. WIRE SMOKE DETECTION TO B#2, AND MAKE PROVISION FOR FAN SHUTDOWN AND FIRE ALARM SIGNAL CIRCUIT. �r'` 13 II ELECTRICAL KEY NOTES: / II EF-I ( � I „ RECEPTACLES ABOVE SHOW WINDOWS. l'-0 ABOVE TOP OF STOREFRONT. __ ❑2 SERVICE ENTRANCE DISCONNECT, UTILITY COMPANY CT AND METER ASSEMBLY. `• [ ��- I COORDINATE WITH UTILITY FOR ALL REQUIREMENTS. GYP 16 13 35 B 37 I #1` F I -J a I 1 ❑3 MAIN TELEPHONE BACKBOARD, 4' X 8' X 3/4" PLYWOOD. REFER TO 17/E3.1. �B �. `s 6 -� -��� u I AUTOMATIC DOOR CIRCUIT INDIVIDUALLY AS INDICATED. VERIFY EXACT `"'� /✓ I ( EF B3_ I LOCATION AND CONNECTION. ER EDWARDS 725. MOUNTED IN JOIST SPACE. CIRCUIT TO A 28. 1 , `�� ❑5 BUZZ # # R fU - I 6 PUSH BUTTON FOR DOOR BUZZER MOUNTED AT 54°AFF. PROVIDE ALL WIRING m.� 5 AND CONNECT TO BUZZERS PER MANUFACTURERS INSTALLATION INSTRUCTIONS. CONNECT TO CIRCUIT A 28. h ! i ' - I - --- ❑7 PROVIDE JUNCTION BOX AT BOTTOM CORD OF BAR JOIST FOR "ANIMAL 11 ADP/ 5,27, 9 _ �........ r l� I — 11 i : �___ PETTER" DISPLAY. PROVIDE TYPE ALT ALUMINUM LIQUID TIGHT CONDUIT, 200 3 110 —_. _ ) B 19 ( EMA1 3R(. I 1 J �`- "--'' -� - - - - f BLACK AND CONDUCTORS AS REQUIRED AFTER DISPLAY HAS BEEN SET AT fl # f I ! B 1 11 I I TIME OF STORE FIXTURING WHILE VENDOR IS ON SITE. PROVIDE MC CABLE r,: I r ..-v_ f- 1 INSIDE DISPLAY AND MAKE FINAL CONNECTIONS TO HABITATS AS REQUIRED. ::::...:. I MDP 20,22,24 r _ _ RTU 100 3/80 LL_'�'-� A#8 ! I ® SQUARE D CLASS 2510 #KO3 MANUAL SWITCH OR EQUAL FOR UNII HEATER. `� � : � � 2 `'•• I NEMA 3R g � I ! MOUNT SWITCH ON WALL ABOVE CEILING. ---❑ - - -�� - - Lam-- -- L---� 2 Q 2219 .`�# G 221 ! ! ❑9 PROVIDE RTU DISCONNECT SWITCH AS SHOWN. I --- ---- l I �20 _ I I�f,Tm,I 10 INTEGRATED POWER & CONTROL ASSEMBLY. REFER TO SHEETS E1.2A, E1.2B, E1.3 AND EMS1.1. I 11 GFCI DUPLEX RECEPTACLE WITH WEATHERPROOF, UNATTENDED, WHILE -IN -USE (,3 �) 2 A#8 I I ! I COVERPLATE FURNISHED WITH HVAC UNITS. POWER POLE ON MULLION FOR QUICK TAG AND SODA COOLER, WITH - _ RECEPTACLE TO CIRCUIT A 24 AND A 26 RESPECTIVELY. IF FURRED OUT - #3 �__J I i ! WINDOW BASE EXISTS, PROVIDE DUPLEX RECEPTACLE IN LIEU OF POWER POLE. 1O'-0" r -4- Iq#3 ! I ! RECEPTACLES ARE TO BE GRAY IN COLOR. 1 7 22 2 I ! ! 13 SWITCH FOR EXHAUST FAN. HUBBELL NUMBER CS1221 OR EQUAL. 02 -- 21 B#31 B#33 , -_ 14 PROVIDE 3 -0 HORIZONTAL SECTIONS OF PLUG MOLD ALONG ENTIRE FIXTURE 3 CR#g I` ` .� J �> I ! ❑ BOTH SIDES, 6" ABOVE BASE OF GONDOLA WITH OUTLETS EVERY 2'-0". CIRCUIT _A##4Q 2 1 ! AS SHOWN. 4 , / --- •-- 15 JUNCTION BOX MOUNTED AT BOTTOM CHORD OF BAR JOIST FOR END CAP �j DISPLAY CONNECTED TO EMS CONTROLLED CUSTOMER LIGHT CIRCUIT. c)B#2`1 r ` CONTRACTOR TO DROP CONDUCTORS IN 3 4" CONDUIT DOWN SPINE OF �MDP{�9.21,231 j -`�-� - � - r RACKING TO BASE. VERIFY LOCATION WITH PETCO PROJECT MANAGER PRIOR TO 10 , ! INSTALLATION. SEE DETAIL 13/E3.1. LABEL WITH CIRCUIT NUMBER. CONDUIT 11 (NEMAI,3R�g '� - - - - - - i ! PAINTED PER ARCHITECTURAL PLANS. -- _. r ...........;;�_ -I - -�C` q#g I I ! 16 JUNCTION BOXES MOUNTED AT BOTTOM CHORD OF BAR JOIST FOR LIVE ANIMAL . �• �;::;::::;:;:•::; - __ DISPLAY. DROP POWER TO DISPLAY AFTER DISPLAY HAS BEEN SET AT TIME OF RTU , I __.-_ - _ __. 5 ! ! STORE FIXTURING WHILE VENDOR IS ON SITE. PROVIDE MC CABLE INSIDE I f A DISPLAY AND MAKE FINAL CONNECTIONS TO HABITATS AS REQUIRED. � I � CR B I ®.�-I I ! 1 I 17 PROVIDE TYPE SJ-T, 12 AWG, COILED POWER CORD (SIMILAR TO RAPID CONN ' 17 - -- DWG. NO. RC-207-0046, EXCEPT IN BLACK) FROM THE BAR JOIST MOUNTED JUNCTION BOX TO THE DISPLAY. BUS DROP GRIPS (HUBBELL CAT. NO. - - -� ----�j 073041278) SHALL BE PROVIDED AT EACH TERMINATION POINT AND A SAFETY 2 _ � _ I\ �` '- � (_� SPRING SHALL BE PROVIDED WHERE THE CABLE DROPS DOWN FROM THE 7 t_-_ A#64 , - - -�<� __. _ �l._." (� I CEILING. THE VERTICAL PORTION OF THE CABLE DROP SHALL BE PLUMB. -- -- -- A ,6_. # 18 OUTLET FOR WATER COOLER TO BE GRAY IN COLOR. 7�. �12 ❑ F, J—BOX MOUNTED AT BOTTOM CHORD OF BAR JOIST FOR FIXTURE END CAP ' B I 04-`� -� A �Z =) I DISPLAY. PROVIDE CONDUIT DROP SIMILARLY TO 13/E3.1. 1 �S 20 LOCATE RECEPTACLE WITHIN 3'-0" OF GROOMING ROOM FOR GROOMING SIGN, 12" 2 I ❑ ABOVE TOP OF STOREFRONT. IF NO STOREFRONT EXISTS AT THIS LOCATION, _EF. PROVIDE CEILING RECEPTACLE OVER GROOMING VESTIBULE DOOR. DUPLEX RECEPTACLE ON UNISTRUT IN JOIST SPACE FOR SECURITY MONITOR. CIRCUIT AS SHOWN. WITH PETCO PM r--- 09 � I ; I , I 22 VERIFY EXACT ELECTRICAL REQUIREMENTS AND LOCATIONS PRIOR TO ROUGH IN. _ _. - - -- --- ELECTRICAL POWER PLAN REF.: WOMEN'S 108 MEN'S 109 ISO ROOM 117 WORK ROO 11a CLOSET 120 BREAK RM PRE -SALES 02 KEY PLAN 1/8" =1'-0" REF.: 1_4-,gCAGE ROOF 105 TUB ROOM -105 < GROOMING SALON 107 -`� GROOMING RECEPTION 104 .� VESTIBULE 101 F_ 9 AQUARIUM AREA 115 OFFICE 113 1` 01 NO SCALE 0 oc Q jJ O (D 0 o� W o, P" o wto <r NxZCV PZ D Wc�l Fes/ W�tLW�CD� CCU �-LO 0� LN 1-+•��YUpU�W !n W W Qwx�-L 0 0. �x JWl`J` O U N _j vi Ica U w ,w w_ J w J m .-I • �z CO LL" ® 06 z� J � W 0co d �� 0 wzR U a-Cn Q I—O� z U LL. 1L I LLI LLI - uiD o wo0 z z LL W � z OU)U) � s a z 0 ory oa 0 edWW 9L!r cj N Z V) U1 _j DISTRIBUTION: WE 25% REVIEW 07/19/04 75% REVIEW 07/28/04 98% REVIEW 08/06/04 PERMIT 08/13/04 ADDENDUM #1 08/19/04 ADDENDUM #2 10/20/04 HEI JOB 8 PETCO P.M. JOB 8 0450000526 DRAWN: CHECKED: ALR BJT DRAWNG TITLE: ELECTRICAL POWER PLAN E2.2 c; , C Fl) rF �o_ Q j� A) i Z 1I CALL BOX CONFIGURATION Q DEPARTMENT MESSAGE TEXT AE GROOMING SUPPLIES "CUSTOMER SERVICE TO GROOMING SUPPLIES PLEASE" AA BIRD "CUSTOMER SERVICE TO BIRD PLEASE" AF REPTILES "CUSTOMER SERVICE TO REPTILES PLEASE" AB AQUATICS "CUSTOMER SERVICE TO AQUATICS PLEASE" AG SMALL ANIMALS "CUSTOMER SERVICE TO SMALL ANIMALS PLEASE" AC DOG HOUSES "CUSTOMER SERVICE TO DOG HOUSES PLEASE" AH COLLARS AND LEADS "CUSTOMER SERVICE TO COLLARS AND LEADS PLEASE" AD KENNELS AND CRATES "CUSTOMER SERVICE TO KENNELS AND CRATES PLEASE" AJ CATS "CUSTOMER SERVICE TO CAT DEPARTMENT PLEASE" ELECTRICAL SOUND & COM. PLAN REF.: NOTES REF.: GENERAL ELECTRICAL NOTES: 1. THIS DRAWING DEPICTS RESPONSIBILITIES OF MULTIPLE PARTIES FOR THE SOUND AND COMMUNICATION SYSTEMS. GENERALLY, SYSTEM OUTLETS, DEVICES, EQUIPMENT, AND WIRING IS BY PETCO'S VENDOR. PROVISIONS TO FACILITATE INSTALLATION, SUCH AS JUNCTION BOXES, CONDUIT AND PULL STRINGS, ARE BY THE ELECTRICAL CONTRACTOR (E.C.). 2. ALL WALL MOUNTED JUNCTION BOXES AND PULL BOXES SHALL HAVE CONDUIT AND PULL STRING BY E.C. UP AND OUT WALL AT BOTTOM OF NEAREST BAR JOIST (UNLESS OTHERWISE NOTED). 3. CONDUITS IN PRE -SALES AREA MAY BE RUN EXPOSED. 4. ALL EXPOSED WIRING (FROM JUNCTION BOX TO DEVICE) SHALL BE IN FLEXIBLE ARMOR WHERE SUBJECT TO DAMAGE. 5. ALL EMPTY JUNCTION BOXES SHALL HAVE A COVER PLATE. 6. SOUND SYSTEM EQUIPMENT AND WIRING FURNISHED AND INSTALLED BY PETCO'S VENDOR. 7. ALL DIMENSIONS, IF SHOWN, ARE FROM THE INSIDE FACE OF MASONRY WALL. REFER TO 17/E3.2 FOR EXACT LOCATIONS OF P.O.S. AREA TELEPHONE AND DATA OUTLETS. REFER TO 14/E3.2 FOR EXACT LOCATIONS OF OFFICE AREA TELEPHONE AND DATA OUTLETS. 8. EQUIPMENT IN WET AREAS SHALL BE SUITABLE FOR WET LOCATIONS. 9. VERIFY EXACT LOCATIONS AND MOUNTING HEIGHTS OF ALL DEVICES WITH PETCO PM PRIOR TO INSTALLATION. COMMUNICATION SYSTEM LEGEND (W x H x D) If TELEPHONE OUTLET IN 2"X4"X2" JUNCTION BOX WITH 3/4" CONDUIT TO ABOVE CEILING OR TO BOTTOM CORD OF BAR JOIST IN OPEN AREAS. VKSU KSU LOCATED NEXT TO TELEPHONE COMPANY M.P.O.E. AT MAIN TELEPHONE TERMINAL BOARD ("MTB"). SEE DRAWING E2.2 FOR LOCATION. SCR TELEPHONE OUTLET MOUNTED IN CASHIER COUNTER, WITH WIRING FED THROUGH DATA CHANNEL IN POWER POLE. REFER TO 17/E3.2. FAQ TELEPHONE OUTLET MOUNTED IN POWER POLE WITH WIRING FED THROUGH DATA CHANNEL IN POWER POLE. REFER TO 14/E3.1. 0 DATA OUTLET IN 2"X4"X2" JUNCTION BOX WITH 3/4" CONDUIT TO ABOVE CEILING OR TO BOTTOM CORD OF BAR JOIST IN OPEN AREAS. VCR DATA OUTLET MOUNTED IN CASHIER COUNTER, WITH WIRING FED THROUGH DATA CHANNEL IN POWER POLE. REFER TO 17/E3.2. M TR DATA OUTLET IN 2"X2"X4" JUNCTION BOX MOUNTED AT 10'-0" ON CHASE WALL FOR TRANSMITTER/ RECEIVER FOR HANDHELD CHECKERS. PROVIDE PLASTIC LAMINATE ON 10"X10"X V8" PARTICLE BOARD SHELF ON BRACKETS MOUNTED ON WALL AT 9'-8"AFF. SEE 06200 FOR PLASTIC LAMINATE COLOR, 08710 FOR SHELF BRACKET. OPS DATA OUTLET IN 2"X4"X2" JUNCTION BOX AT 10'-0"AFF, WITH 3/4" CONDUIT UP TO BOTTOM CORD OF BAR JOIST. PROVIDE SHELF AND MOUNT SIMILAR TO DATA OUTLET 'TR' ABOVE. 8AX 2"X4"X2" JUNCTION BOX AT 48"AFF. WITH 3/4" CONDUIT UP TO BOTTOM OF BAR JOIST FOR "AUTO -ATTENDANT CUSTOMER SERVICE BOX". VERIFY LOCATION WITH LATEST FIXTURE PLAN. SEE SCHEDULE, PROFESSIONAL ENGINEER Cra i q R. LanhOFT) FL PE# — 40650 I SOUND SYSTEM LEGEND (W x H x D) I O SOUND SYSTEM SPEAKER MOUNTED FROM BOTTOM OF BAR JOIST. SOUND SYSTEM SPEAKER FLUSH MOUNTED IN CEILING -FILE. COORDINATE LOCATION WITH LIGHT FIXTURES AND DIFFUSERS/ GRILLES. Fo 2"X4"X2" JUNCTION BOX WITH 1 1/2" EXTENSION RING FOR SOUND SYSTEM VOLUME CONTROL. MOUNT AT 42" AFF. WITH 1/2" CONDUIT UP TO JOIST SPACE. VERIFY LOCATION IN FIELD. T'(; 2"X4"X2" JUNCTION BOX WITH 1 1/2" EXTENSION RING FOR EMPLOYEE TIME CLOCK. MOUNT AT 42" AFF. WITH 1/2" CONDUIT UP ABOVE CEILING, VERIFY LOCATION IN FIELD. WOMEN'S 10a MEN'S 109 ISO ROOM 117 WORK ROOK 11a CLOSET 1'LO BREAK RM 112 CLOSET 110 PRE -SALES 02 KEY PLAN 1/8" = V-0" REF.: CLOSET F(D 1C�AE ROOT TUB ROOM 106 GROOMING G VESTIBULE �a 101 AQUARIUM - AREA 115 OFFICE --113 IFE) (D 01 NO SCALE Ln 0 z Ln �0 �a 0 F `O _w w 20 �(o i N L< �� �CUWLOLN Q rrr� V) 0 E-VI U(n z 0 cl� p1U rsOp�rw ww r`) L `t 1�7 W W Q lY (y- < I O2!x^1 �x w0 J Lj j w O � U NJr�r W O> Lp �1 J W w F- 0 m J J Q ■ Ix] Z L .�, 06 J <w Om o OJL1! Q Z Iry cn 1-oo ZULL_ Lu Lu w Lu 0 ry F_U< N Ql z 0 ad�U Q 0 UU dL�U wW �y za �) DISMILMION: DATE: 25% REVIEW 07/19/04 75% REVIEW 07/28/04 98% REVIEW 08/06/04 PERMIT 08/13/04 ADDENDUM #2 10/20/04 FIEI JOB # PErCO P.M. JOB U 0450000526 DRAWN: CHECKED: ALR BJT DRAWING TITLE: SOUND AND COMMUNICATION SYSTEM E2.3 I I `"' - 1 I I I I i I II i I iI II I Ili I� i I I I. li I� I l I 0 L 1-9 A#41 L t- 13 A#2319 ---r.-rNrtd FS .rS -- (F...) E Cc. I ( I I I I I II II 10 10 17F g I _ -- I - - I - - --L--= Ll I L - - I ___J ___ i - __ t=---J - I 1 -1 1 - _L - -1 - L SECURITY SYSTEM PLAN REF.: NOTES PROFESSIONAL ENGINEER REF.: Craig R. Lanham FL PE# — 48650 GENERAL ELECTRICAL NOTES: 1. THIS DRAWING DEPICTS RESPONSIBILITIES OF MULTIPLE PARTIES FOR THE SECURITY AND ALARM SYSTEMS. GENERALLY, SYSTEM COMPONENTS, DEVICES, AND WIRING IS BY PETCO'S VENDOR. PROVISIONS TO FACILITATE INSTALLATION, SUCH AS JUNCTION BOXES, CONDUITS, AND PULL STRINGS ARE BY THE ELECTRICAL CONTRACTOR. 2. ALL CONDUITS WILL BE TERMINATED AT BAR JOIST LEVEL WITH SOME FORM OF BUSHING OR BOX CONNECTOR. 3. ALL CONDUITS LOCATED IN DRYWALL SHALL BE TERMINATED 6" ABOVE CEILING TILE. 4. ALL CONDUITS IN DRYWALL LOCATIONS TO BE RECESSED INSIDE WALL. 5. NO EXPOSED CONDUIT IS ALLOWED IN THE SALES FLOOR. 6. SMOKE DETECTORS FURNISHED AS INDICATED ELSEWHERE ON THE DRAWINGS. 7. JUNCTION BOXES FOR SECURITY SYSTEM DEVICES ARE NOTED AS 4"X4"X2" (QUAD BOX 2" DEEP). JUNCTION BOXES FOR FIRE ALARM DEVICES ARE NOTED AS 4"X4"X3" (QUAD BOX 3" DEEP). ELECTRICAL KEY NOTES: ❑1 DOOR CONTACT - RECESSED 4"X4"X2" JUNCTION BOX 4" ABOVE THE OPENTING AND EVEN WITH THE EDGE OF THE OPENING. STUB 3/4" CONDUIT INSIDE WALL TO BAR JOIST LEVEL. �2 DOOR CONTACT (NON SALES FLOOR) - 4"X4"X2" JUNCTION BOX CENTERED AT 4" ABOVE THE OPENING AND STUB 3/4" CONDUIT TO BAR JOIST LEVEL. �3 VESTIBULE SLIDING DOORS - RECESSED 4"X4"X2" JUNCTION BOX CENTERED AT 4" ABOVE HEADER/OPENING OF SLIDER DOOR. LOCATE BOX AT EDGE OF OPENING. STUB 3/4" CONDUIT INSIDE WALL TO BAR JOIST LEVEL. ® GLASS BREAK SENSOR (DROP CEILING) - 4"X4"X2" JUNCTION BOX AT BAR JOIST. INSTALL 3/4" FLEXIBLE CONDUIT TO SINGLE GANG JUNCTION BOX IN ORDER TO EXTEND BELOW CEILING GRID 2'-0". ❑5 GLASS BREAK SENSOR (OPEN JOIST CEILING) - RECESSED 4"X4"X2" JUNCTION BOX AT 2'-0" ABOVE GLASS AND STUB 3/4" CONDUIT INSIDE WALL TO BAR JOIST LEVEL. © OVERHEAD DOOR CONTACT - 4"X4"X2" JUNCTION BOX ADJACENT TO TOP OF OPENING FOR OVERHEAD DOOR. PLACE BOX WITH BOTTOM 2" ABOVE OPENING AND EDGE OF THE BOX THAT FACES THE OPENING 6" AWAY FROM OPENING. STUB 3/4" CONDUITS TO BAR JOIST LEVEL, ALSO STUB 3/4" CONDUIT DOWN TO A 4"X4"X2" JUNCTION BOX MOUNTED AT 6" AFF. ENSURE THAT BOX DOES NOT INTERFERE WITH THE LOCATION OF THE OVERHEAD DOOR TRACKS/MOUNTING HARDWARE, SOME DOORS MAY NOT ALLOW TOP MOUNTED SWITCHES. (SEE ALARM DEALER IF THAT IS THE CASE) a REMOTE TEST STATION - INSTALL REMOTE TEST STATION FOR EACH SMOKE DETECTOR 1'-O" ABOVE TEMPERATURE SENSOR FOR RESPECTIVE I-IVAC UNIT. WIRE THE SMOKE DETECTORS AND REMOTE TEST STATION TO DE -ENERGIZE THE SUPPLY FAN AND SEND AN ALARM SIGNAL TO THE FIRE ALARM CONTROL PANEL UPON SENSING SMOKE. ONLY WHERE REQUIRED BY AUTHORITIES HAVING JURISDICTION, PROVIDE SMOKE DETECTOR INTERCONNECTION FOR MULTIPLE FAN SHUTDOWN. ® NOT USED. ROOF HATCH - 4"X4"X2" JUNCTION BOX ADJACENT TO ROOF HATCH. 10 FIRE ALARM HORN/STROBE - PROVIDE 4"X4"X3" JUNCTION BOX AT 6'-8" AFF TO BOTTOM OF BOX AND STUB 3/4" CONDUIT TO THE BAR JOIST LEVEL. 11 MANUAL PULL STATION (OPTIONAL HORN/STROBE) - PROVIDE 4"X4"X3" JUNCTION BOX AT 4'-0" AFF TO BOTTOM OF BOX. FINISH WITH A SINGLE TRIM RING AND STUB 3/4" CONDUIT TO A 4"X4"X3" JUNCTION BOX WITH BOTTOM AT 6'-B" AFF, THEN STUB 3/4" CONDUIT TO BAR JOIST LEVEL. (NOTE: IF THERE IS A PULL STATION ONLY, DO NOT PUT BOX AT 12 DUCT SMOKE DETECTOR - PROVIDE 3/4" FLEXIBLE CONDUIT FROM DUCT DETECTOR HOUSING TO SINGLE GANG JUNCTION BOX AT BAR JOIST LEVEL. 13 FIRE SPRINKLER WATER FLOW & TAMPER SWITCH - PROVIDE FLEXIBLE CONDUIT FROM EVERY DEVICE TO INDIVIDUAL 4"X4"X3" JUNCTION BOX MOUNTED AT 4'-0" AFF. AND STUB 3/4" CONDUIT r0 BAR JOIST LEVEL. 14 SAFE - 4"X4"X2" JUNCTION BOX AT 1'-6" AFF, AND STUB 3/4" CONDUIT TO THE BAR JOIST LEVEL. 15 FIRE/BURGLAR ANNUNCIATOR - PROVIDE BACK BOX AND CONDUIT TO STRUCTURE FOR FIRE ALARM AND BURGLAR ANNUNCIATOR PANEL. VERIFY EXACT ELECTRICAL REQUIREMENTS WITH INSTALLER PRIOR TO ROUGH -IN. 16 OFFICE 360' IR - PROVIDE JUNCTION BOX AT BAR JOIST LEVEL AND STUB 3/4" FLEXIBLE CONDUIT TO JUNCTION BOX AT CEILING GRID. VERIFY EXACT ELECTRICAL REQUIREMENTS WITH INSTALLER PRIOR TO ROUGH -IN. 17 PANEL SMOKE - PROVIDE JUNCTION BOX AND CONDUIT FOR SMOKE DETECTOR. VERIFY EXACT ELECTRICAL REQUIREMENTS AND LOCATION WITH INSTALLER PRIOR TO ROUGH -IN. 18 BURGLAR ALARM CONTROL PANEL - COORDINATE LOCATION AND INSTALLATION WITH VENDOR. PROVIDE CIRCUIT AS SHOWN. 19 FIRE ALARM CONTROL PANEL - COORDINATE LOCATION AND INSTALLATION WITH VENDOR. PROVIDE CIRCUIT AS SHOWN. 20 POWER PANEL - COORDINATE LOCATION AND INSTALLATION WITH VENDOR. PROVIDE CIRCUIT AS SHOWN. WOMEN'S CLOSET 114 MEN S C: `-- - - <gCAGE ROOt 109 ISO ROOM I I I — i 105 I l (� �� I TUB ROOM 117 Sx WORK ROOM ` _-- -- _- J 106 118 L ��i GROOM ING SAL CLOSET 120 - I 107 BREAK RM/� GROOMING r RECEPTION 112 ( I I \ 1 104 CLOSET I \ l _ I VESTIBULE 110ol PRE -SALES AQUARIUM AREA OFFICE 113 Ii I I N 02 KEY PLAN 01 118" = V-0" REF.: NO SCALE J m J m • U z �. LL- od z� > w 0 m o ® 0`� LL.. Iz z E U ®— Qw-00 W z U LL. 0- w � w w U_� w o 0_.U) U'Zo w z O�U) in a z O LL �U OCTedwW Lr s L DISTRIBU[ION: DATE: 25% REVIEW 07/19/04 75% REVIEW 07/28/04 98% REVIEW 08/06/04 PERMIT 08/13/04 ADDENDUM /#2 10/20/04 HEI JOB It PErCO P.M. JOB it 0450000526 DRAWN: CHECKED: ALR BJT DRAWNG TITLE: SECURITY SYSTEM PLAN E 2.4 i I ✓� E I I I I F_ 1 I II 11lfll�w I S _RTUr4 I , I I I I I RTU-3 III -� -_ - - _ __ S 9 /N .� uo . ->t � -- �' _ __ . ,� >, _ I I I I I v .y S 4 t� it 11 Lf_._ iiT ENERGY MANAGEMENT SYSTEM PLAN REF.: NOTES REF.: GENERAL ELECTRICAL NOTES: 1. REFER TO SHEET EMS1.1 FOR ADDITIONAL CONTROL SYSTEM INFORMATION. 2. REFER TO SHEET E1.3 FOR CONTACTOR SCHEDULE. 3. NO SENSOR WIRING SHALL BE INSTALLED UNSUPPORTED BY TIE -WRAPS OR CONDUIT. 4. ALL SENSOR WIRING INSTALLED EXPOSED BELOW THE BOTTOM OF THE CHORD OF BAR JOIST SHALL BE INSTALLED IN EMT CONDUIT OR SHALL BE CONCEALED BEHIND WALLS OR CEILINGS OR INSTALLED THROUGH HOLLOW MULLIONS. ELECTRICAL KEY NOTES: ❑1 LOCATE SENSOR JUNCTION BOX IN RETAIL AREA AT 72" AFF. WHERE POSSIBLE DO NOT LOCATE SENSOR DIRECTLY IN AIR— STREAM OF ANY RTU. ❑2 AIR CONDITIONING DUCT SENSOR ON SUPPLY AIR DUCT WITH PROBE IN SUPPLY AIR STREAM. ❑3 TEMPERATURE AND HUMIDITY SENSOR JUNCTION BOX AT 54" AFF. ® LOCATE AIR CONDITIONING DUCT SENSOR ON EXHAUST DUCT WITH PROBE IN EXHAUST AIR STREAM. u LOCATE DRYER VENT DUCT SENSOR ON WALL AT 24" AFF WITH PROBE IN VENT DUCT. PROVIDE ACCESS PANEL IN WALL AT SENSOR LOCATION. © ISOLATION ROOM TEMPERATURE SENSOR AT 54". PRE -SALES AREA TEMPERATURE SENSOR AT 54", MOUNT THERMOSTAT ON INSULATING BLOCK. ® MOUNT THE REMOTE TEMPERATURE SENSOR ON THE REAR WALL OF THE FREEZER COMPARTMENT. DRILL A HOLE THROUGH THE WALL BEING SURE TO MISS THE SHELF STANDARDS AND INSERT THE PROBE THROUGH THE HOLE. TIE -WRAP THE PROBE AND WIRE TO THE FREEZER WALL AND PLUG THE HOLE WITH A SUITABLE COMPOUND. LEAVE A 7'-0" LENGTH OF CONNECTOR CABLE LOOSE BEHIND THE FREEZER TO ALLOW UNIT TO BE PULLED OUT FOR SERVICE. SEE DETAIL 18/E3.1. n9 VESTIBULE 'TEMPERATURE SENSOR AT 54". 10 CAGE ROOM TEMPERATURE SENSOR AT 54". 11 OUTSIDE AIR AND PHOTOCELL SENSOR. LOCATE SENSOR ON 3' LONG, 1/2"0, RIGID CONDUIT ABOVE ROOF FACING NORTH. 12 ROLL -UP DOOR SENSOR. MOUNT AT BOTTOM EDGE OF DOOR ON OPPOSITE SIDE FROM SECURITY SYSTEM DOOR SENSOR. 13 FRONT DOOR CONTACT SENSOR. MOUNT AT TOP OF DOOR JAMB. 14 PROVIDE FISH TANK SENSOR FOR EACH 8' AND 4' AQUARIUM SECTION. 15 OVERRIDE PANEL IN MANAGER'S OFFICE AT 54" AFF. 16 SECURITY ALARM SYSTEM MONITOR IN THE PRE -SALES AREA ADJACENT TO THE HILL PHOENIX EQUIPMENT. 17 REFER TO ARCHITECTURAL PLANS FOR DETAILS ON AQUARIUM TANK CHASE WALL FOR UTILITIES. j8 INSTALL ACCUSTAT ON BIRD ROOM STOREFRONT MULLION OPPOSITE CABINET UNIT HEATER (ON HINGE SIDE OF DOOR), MOUNTED AT 54"AFF TO TOP OF ACCUSTAT. LOW VOLTAGE CONTROL WIRING SHALL BE FISHED DOWN IN DOOR —JAMB, NO EXPOSED WIRING OR CONDUIT PERMITTED. WOMEN'S 108 MEN'S 109 ISO ROOM 11 "/ WORK ROOK 118 CLOSET 120 BREAK RM 112 CLOSET 110 PRE -SALES 02 KEY PLAN 1/8" = V4, REF.: PROFESSIONAL ENGINEER Cra i g R. Lanharn FL PE# — 48550 CLOSET 114 -i CAGE ROOD 1U5 FUB ROOM 106 GROOMING SALON I�-107 GROOMING RECEPTION 1 44 VESTIBULE 101 AQUARIUM c� AREA 115 OFFICE 113 N 01 NO SCALE 1 J CLa J m �.% _I H ® ^06 u/ > W Q 0 m ❑ _o Z OIL (n Z U LL �...� W W❑ wD 0WOO ZZ �cn W��Z 0 U) U) � s N Q o ed�o pU ,r w 9L�y L Q rnm DIurRIBUTION: WE 25% REVIEW 07/19/04 75% REVIEW 07/28/04 98% REVIEW 08/06/04 PERMIT 08/13/04 ADDENDUM #2 10/20/04 HEI JOB iF PETCU P.M. JU[3 it 0450000526 URAWN: CHECKED: JCC BJT DRAWING ME: ENERGY MANAGEMENT SYSTEM PLAN E 2.5 / lot, C Li LL D V a c E T FREEZER SENSOR JUNCTION BOX (SEE 02/E2.5 FOR LOCATION). PROVIDE ONLY AT ISLAND WITH FREEZER. - RECEPTACLE FOR BUBBLE TUBES. SIMPLEX RECEPTACLE (15/20A) OR POWER JUNCTION BOX (SEE 02/E3.1 TO DETERMINE WHICH) AT 16" AFF. IF JUNCTION BOX, PROVIDE 10'-0" LIQUID TIGHT FLEXIBLE CONDUIT WHIP FROM JUNCTION BOX FOR CONNECTION TO REMOTE DEVICE. COORDINATE WITH PLAN 02/E3.1 FOR SPECIFIC REQUIREMENTS. � r oil CIRCUIT AS SHOWN I UNCTION BOX IT SPANNING BOTTOM EMBER TO RESTRAIN AND YET ALLOWING STRESS ON POWER \v CASH REGISTER POWER POLE DETAIL REF.: 17/E3.2 REFER TO ARCHITECTURAL PLANS FOR ENCLOSURE DETAILS. NOTES REF.: SENSOR WIRE DOWN THROUGH CHASE TO I 'I BACK OF FREEZER Unused GENERAL ELECTRICAL NOTES: MOUNT THE REMOTE TEMPERATURE SENSOR - T ^ ^ 1. REFER TO PANELBOARD SCHEDULES FOR AQUARIUM ON THE REAR WALL OF THE FREEZER ------ ELECTRICAL LOADS. COMPARTMENT, DRILL A HOLE THROUGH THE WALL IN THE SHADED AREA BEING SURE TO i FUTURE I I i FUTURE I 2. REFER TO SHEET E2.1 FOR POWER POLES FOR OTHER DISPLAYS. MISS THE SHELF STANDARDS AND INSERT o STENCIL AS: I I I I I STENCIL AS: THE PROBE THROUGH THE HOLE. TIE WRAP RESERVED FOR PETCO I- I III I I I I I RESERVED FOR 3. VERIFY WITH PETCO'S EQUIPMENT PLAN ALL AQUARIUM TYPES THE PROBE AND WIRE TO THE FREEZER WALL TELEPHONE SYSTEM L----J I----� PETCO FIRE & AND LOCATIONS. AND PLUG THE HOLE WITH A SUITABLE I SECURITY SYSTEMS COMPOUND. LEAVE A 7'-0" LENGTH OF �I �� 4. EACH AQUARIUM POWER JUNCTION BOX TO BE CONNECTED TO CONNECTOR CABLE LOOSE BEHIND THE STENCIL AS: STENCIL AS: AN 8' FLEXIBLE WATER TIGHT CONDUIT CONTAINING HOT, FREEZER TO ALLOW UNIT TO BE PULLED OUT RESERVED FOR I I RESERVED FOR NEUTRAL AND GROUND WIRES FOR EACH CIRCUIT. FOR SERVICE. TELCO UTILITY r-1 r- I I i TELCO UTILITY DEMARC I I I FUTURE I I I I I I I I DEMARC 5. AQUARIUM LIGHTS ARE SWITCHED (CONTROLLED) VIA EMS. SINGLE GANG JUNCTION BOX AT 5'0"AFF ON Ii i i I �J `-� I i i 6. ALL DEVICES NOT SPECIFICALLY DIMENSIONED MAY BE LOCATED CHASE WALL SEE 04/E3.1 ;� L____J I +/- 8" IN EITHER DIRECTION IN PLAN FROM 'THEIR APPROPRIATE LOCATION SHOWN (TO NEAREST STUD OR NEAREST' CMU CORE). PROVIDE GROUND BAR SQ-D ELECTRICAL KEY NOTES: o I -----I #PIC270TA OR EQUAL, GROUND N PER NEC. TIE BACK TO SE ❑1 CHASE WALL FOR ISLAND AQUARIUM LOADS. REFER TO GROUNDING ELECTRODE. AQUARIUM AREA FALSE COLUMN DETAIL 04/E3.1 FOR FINISHED FLOOR CONFIGURATION. NOTE: STENCIL BACKBOARD AS SHOWN ON INSTALLATION. ❑2 TELEPHONE OUTLET INSTALLED ABOVE COUNTER. FREEZER SENSOR DETAIL 18 TELCO BACKBOARD 17 ❑3 RECEPTACLE FOR FREEZER/COOLER (NEMA 14-20R). VERIFY REF.: 02/E3.1 NO SCALE REF.: 02/E2.2 NO SCALE TYPE REQUIRED WITH EQUIPMENT PROVIDED. INS -FALL ON BACK OF BAGGING STATION. J-BOX AT BAR ® NOT USED JOIST ABOVE �5 PROVIDE LOW VOLTAGE ALARM SENSOR WIRING IN 3/4" CONDUIT PAINT EXPOSED CONDUIT DOWN FALSE COLUMN TO JUNCTION BOX. REFER TO 18/E3.1. PER ARCHITECTURAL PLANS 6 CIRCUIT POWER JUNCTION BOXES FOR AQUARIUM TANKS TO EXPOSED RIGID METAL AQ#17,19,21,23. CONDUIT AT BACK SIDE OF ENDCAP FIXTURE. PROVIDE SUPPORT AS REQUIRED PER NEC. J-BOX FASTENED TO BASE OF GONDOLA FLUSH WITH END CAP. PROVIDE DUPLEX OUTLET OR 3' OF HORIZONTAL PLUGMOLD WHERE NOTED ON E2.2. FINISHED FLOOR E_f�_ END CAP DISPLAY — "— GONDOLA 14 END CAP CONDUIT DROP NO SCALE REF.: 02/E2.2 DUPLEX OUTLET FOR AQUARIUM LIGHTING AT 72" AFF, TYPICAL FOR FOUR. OUTLETS SHALL BE GREY IN COLOR. RECEPTACLE FOR BUBBLE TUBES. POWER JUNCTION BOX FOR AQUARIUM POWER AT 15" AFF. TYPICAL FOR FOUR. PROVIDE 10'-0" LIQUIDTIGHT FLEXIBLE CONDUIT WHIP FROM EACH AQUARIUM POWER JUNCTION BOX FOR CONNECTION TO AQUARIUM TANKS BY OTHERS. AQUARIUM FALSE COLUMN DETAIL REF.: 02/E2.5; 02/E3.1; 18/E3.1 04 NO SCALE PLUGMOLD. SEE FLOOR PLANS FOR LOCATIONS 13 1 OPEN NO SCALE I REF.: 12 NO SCALE I 5 B#30 fJ _ AQ#29 - AQ# 9_�-------- - r— 2 B#32 10:� I AQ#25 AQ#31 B#26 1fl PROVIDE SIMPLEX RECEPTACLE (15/20A RECEPTACLE) ON FALSE COLUMN FOR FEEDER TANK. ® DUPLEX RECEPTACLE A#15 MOUNTED TO CHASE WALL AT 10'-0" AFF FOR TRANSMITTER/RECEIVER FOR HAND HELD CHECKERS a JUNCTION BOX ON FALSE COLUMN FOR FREEZER POWER. PROVIDE LIQUID TIGHT FLEXIBLE CONDUIT FROM JUNCTION BOX TO FREEZER OUTLET INSTALLED ON THE BACK OF THE BAGGING STATION. 10 CIRCUIT POWER JUNCTION BOXES FOR AQUARIUM TANKS TO AQ#9,11,13,15. 11 RECEPTACLE FOR BUBBLE TUBE. CIRCUIT AS SHOWN. WOMEN'S 1oa MEN'S 109 ISO ROOM 117 WORK ROO& CLOSET 120 BREAK RM 112 CLOSET LLLi� PRE-SALES LARGE SCALE AQUARIUM AREA PLAN 02 KEY PLAN REF.: 02/E2.2 1/4"=1'-0" REF.: PROFESSIONAL ENGINEER Craig R. Lanham FL PE# — 48650 TUB ROOM 1 66 I- SALOON ING . 107 GROOMING RECEPTION 1 44 VESTIBULE __C_ 101 AQUARIUM -a AREA 115 OFFICE 113 N 01 NO SCALE o z W W L'j W � a'y WC, c� O Z® : aGV)OwOWV) G S O LE L0 % r7) 8 Ld , " ' iyl W �W ®L X F (Y U X J W p i G rl)� of W U W N U W W . W H J m J ®LL «s zU J <w Omo 0_j �ZW Q �00 U) z U LLL IL LAND I w w O w o w w �.U) QzzO w��z °- d cwn < ®_yr {� • AN adOc L G U- o orU VLW �G tV rn� DISTRIBUTION: WE 25% REVIEW 07/19/04 75% REVIEW 07/28/04 98% REVIEW 08/06/04 PERMIT 08/13/04 ADDENDUM #2 10/20/04 HEI JOB 4 PE-rco P.M. JOB B 0450000526 UMWN: CHECKED: ALR BJT DRAWING T1TLE: ELECTRICAL LARGE SCALE PLANS AND DETAILS E3.1 13#10,12 NOTES PROFESSIONAL ENGINEER POWER TERMINAL Craig R . Lanham EF-7 FAN MOTOR BLOCK ---,,,REF.: FL PE# - " GENERAL ELECTRICAL NOTES: 40`650 Ni SPEED CONTROL Ll L2 C C C A 1. ALL POWER POLES, OTHER THAN THE CASHIER AREA, ARE BY WHITE C -' NTHE CONTRACTOR. SEE SHEET E2.2 FOR SALES AREA POWER ❑CUH-2 IG POLE LOCATIONS. BLACK I 2. ALL DEVICES NOT SPECIFICALLY DIMENSIONED MAY BE LOCATED G +/- 8" IN EITHER DIRECTION IN PLAN FROM THEIR APPROPRIATE LOCATION SHOWN (TO NEAREST STUD OR NEAREST CMU CORE). RELAY - 24V I I I I 00° TRANSFORMER I I I I TYPICAL IG RECEPTACLE 3. CONTRACTOR SHALL RETURN TO THE SITE TO MAKE FINAL RELAY CONTROL I I I I - FOR PANELCR '' ^-- _I fI I -I - I - `, I - CONNECTIONS TO PETCO'S EQUIPMENT AS NECESSARY. ELECTRICAL KEY NOTES: 1"-0 TO PANEL 'A' JUNCTION 7-- - r NOTES: 1"-C TO TEL. "MTB" ❑1 DEDICATED NEMA 5-20R RECEPTACLE FOR FAN CAGE 0#13, 2'-0' BOX AFF. �I ® 1. TYPICAL CASH WRAP DETAIL. VERIFY NUMBER AND LOCATION WITH o -� ARCHITECTURAL PLANS. PROVIDE ADDITIONAL BRANCH CIRCUITS AS g ❑ TIMER ASSEMBLY BY INTEGRATED POWER AND CONTROL -I NECESSARY 1--- - ~ - ASSEMBLY MANUFACTURER. WIRE (TS) CIRCUITS AS SHOWN ON 2. THIS DETAIL IS SCHEMATIC IN NATURE. REFER TO FURNITURE - _ -- "®'� - - al PANELBOARD 'G' SCHEDULE TO TIMERS. ONE TIMER FOR EACH W 01 21V; � �24V LAYOUT AND ORIENTATION, AND FOR ROOM LOCATION FOR CONDUIT-� '--Ir-A#11 IG - - - CIRCUIT. LABEL EACH TIMER FOR CIRCUIT NUMBER. MOUNT �, w o , w w TRANSFORMER DESTINATION. _ _-_ I R# - i r- -01A#9 SUCH THAT TOP SWITCHES ARE 48" AFF. (n W � j `� v, � w G zC zf @ Y w ELEVATION 1 - A#11=QUA 9 �IG=(��ICR#4 3. THERE WILL BE A FLOOR SURFACE CABLE CHASE PROVIDED BY THE I I _ / / 3 SOUND SYSTEM 7'-0" AFF, VERIFY EXACT LOCATION IN FIELD. M�1 �-+ w L w POWER ACCUSTAT �® DI - - �1 ! ❑ (0 w in t PETCO VENDOR, WHICH CONNECTS THE FRONT AND REAR CASH -- -- -- � CIRCUIT in 0 LMS-AH11 WRAP SECTIONS. ROUTE DATA TELEPHONE AND MC CABLE POWER --- -- �= J�`� - 2 _==� r rr,, o a 8,22 Q ® EQUIPMENT FOR SOUND SYSTEM AT 7'-0' . VERIFY LOCATION IN F�+-4 FOR FAN WIRES THAT FEED THE REAR CASH WRAP SECTION UNDERNEATH, 9 FIELD. c o o B#15 ABOVE FLOOR x< P ACCUSTAT LMS-AH11 WIRING DIAGRAM 20 REF.: M1.1,E1.1,E2.2 NONE / I wa`nw0Of ❑5 DUPLEX RECEPTACLE UNDER THE COUNTER FOR SECURITY Q J w a w EQUIPMENT CIRCUIT AS SHOWN. Ci �,z, n a — p— V! J t7 � ail W L 9 -- - - u © WEATHERPROOF RECEPTACLE WITH IN -USE COVER. GRANGER/RACO #5081-Q4, 3/4" COVER DEPTH. INSTALL AT 4'-0" F�1 1� TYP. FOR EIGHT I AFF. —_ — _ ---- ®� -- -- — —p 10 III A# I IG I 7 SQUARE D CLASS 2510 KO3 MANUAL SWITCH OR EQUAL FOR UNIT �...___..�,,A#5 #I _._. C#2 - HEATER. MOUNT SWITCH ON WALL ABOVE CEILING. q#7IC�A#5 1/0 19 DATA OUTLETS IN THIS AREA SHALL BE MOUNTED 42" AFF. 9 TYP. FOR FOUR III CONDUITS TO TERMINATE IN FREE AIR AT BOTTOM OF ROOF r----- ! STRUCTURAL MEMBERS OF RETAIL SIDE OF MANAGER'S OFFICE WALL. LARGE SCALE P.O.S. AREA PLAN 17 9❑ TWO COMPARTMENT POWER POLE FURNISHED BY PETCO VENDOR, INSTALLED AND WIRED BY E.C. SEGREGATE POWER REF.: 02/E2.2 NO SCALE WIRING FROM DATA AND TELEPHONE. FASTEN SIMILARLY TO _ _ - rc. -- I -- 14/E3.1. -:-r ELEVATION 2 10 JUNCTION BOX WITH DUPLEX OUTLET FOR MODEM, LIGHT f ❑ LAQ#34,361-_AQ#40,44_______ I i FIXTURE, AND OTHER GENERAL OUTLET CIRCUIT. +36",+72" +36",+7 11 _ AQ#�8 AQ#30,3r -- -___-.-----_.__.__----.___.----____-.._._-_-----____...._..____ .1.1--________.--._--_--._..__ ..1.1 _�_.____-__-._._ __.-___ ._1. 11 DEDICATED RECEPTACLE FOR 2-HOSE DRYER (TYPICAL). -4-36" -t-7 NOTES: - -- - - -" �, __ -- __ -. _____ ._. _._ _..._ -.- _ _ 18 I -�(T-" -- -�p Tf�' '--'-`- f 12 COORDINATE THE LOCATION OF CONDUITS WITH THE OWNER'S AQ# 2 ;! _.____.._., �� ..___.`;t� i� FURNISHINGS AND OTHER TRADES. REFER TO ARCHITECTURAL -J I 1. DEVICES DIMENSIONED LATERALLY SHALL BE LOCATED +/- 2" FROM i ( I I 11 i �FI-+42" / I LOCATION INDICATED. p I +84" 84 G#16 G#14 G#12 G#13 PLANS FOR DESIGNATED, LIMITED AREA FOR CONDUITS AND m +84" +84" I I +84" +84" II +84" +24" I OTHER TRADES' WORK. J l Q#22 I 2. DEVICES NOT DIMENSIONED LATERALLY MAY BE FASTENED TO NEAREST ( B.OT.T.OM..B9'f..TOM __..-1 I_ BOTTOM -__BOTTOM __JL._BOTTOM__ - l --� W,ti�-�:�VMMAYAN MDP#38,40,42 _. STUD. I I 60/3/NF/ ❑ 13 RECEPTACLE FOR WASHER. PROVIDE ENGRAVED LABEL `� "�-- ---`-- -- �- "WASHER." COORDINATE LOCATION WITH WASHER WASTE HOSE m L_- \` 18 0#19 ( BOX. �_._ r r , ��-�l AQ#33,3 I OFFICE WALL ELEVATIONS 14 I �`- tl ____ _ ____,_ ___ 14 DRYERS ARE PROVIDED IN ONE OF TWO CONFIGURATIONS: 3-POLE, -I( +36 , I-7 f L_. __...__-_....- PANELBOARD G» G 15 2 G#17 C#4U,4, ��#9 4-WIRE AND 3-POLE, 3-WIRE. THE 3-POLE, 4-WIRE �-- �- 06 REF.:09/E3.2 1/4"=1'-0" I ' # -� I_ _- / +42 +42' G 21 CONFIGURATION (TWO HOT, ONE NEUTRAL, ONE GROUND) COMES +12" +12" # _•: - - �1 12 .®8,, �- _- _ I WITH A NEMA 14-30P PLUG. PROVIDE A NEMA 14-30R z ,r�ry , , _._.___._._. I - -. -� _. __.__ RECEPTACLE. THE 3-POLE, 3-WIRE CONFIGURATION (TWO HOTS, ' ' 1 ®m Q _h CIF,--_..--------___-... ONE GROUND) COMES WITH A NEMA 10-30P PLUG. PROVIDE A uj - -._ - NEMA 10-30P RECEPTACLE. SINCE EITHER MAY BE PROVIDED Li- z AQ#2�h 20 `� WITHOUT ADVANCE WARNING, PROVIDE FIVE #10 AWG WIRES IN z LJ � I 15 14 13 15 --_22 EITHER CASE. '� QLJ Q 0 18 +36",-+-7 " _ _ - G 24,26 � � +42" - �� \ 15 ATTACH PETCO PROVIDED CORD KIT TO APPLIANCE. W z U LL _ _ 16 DISCONNECT FOR DOMESTIC HOT WATER HEATER. PROVIDE #3/0 (� 3 - -- r I ;3 ❑ BONDING JUMPER BETWEEN FIO t AND COLD WATER PIPES. W : W O # _ A#2 PANELBOARD - �,� I +412» \� - U z z O A�Q 14,16 AQ 1j0,12 I --�- (I __1__ CR' ��//�� #/ A l 6 j I 0- V J F- - LL i , t 36 ", I-7 I 4 # 9 �� 2 \ / I� 17 PROVIDE JUNCTION BOXES MOUNTED TO TOP OF BIRD ROOM, WITH �� + +72 I-r� 24 `� ---- "- -�, I CONNECTION TO WHIP FROM BIRD ROOM PLUGMOLD. PLUGMOLD IS W W �71 INTEGRAL •1.0 BIRD ROOM DROP POWER FEED THROUGH DISPLAY "'FREE" �" f- (n (( j AQ 22 =� ` 42" F TO BIRD ROOM CEILING AFTER DISPLAY HAS BEEN SET AT TIME OF STORE FIXTURING. PROVIDE HYPE ALT (ALUMINUM LIQUID TIGHT) CONDUIT, BLACK AND CONDUCTORS AS REQUIRED. CIRCUIT TO A#4. +42 HIS ROOM �� - ! L_._____..__-___ __-__._-__.__.. I - i PROTECTED AT THEPELECTRICALrPANELBOARD E C�FCI a TACLES IN L 21-__.._._.. 18 CONVENIENCE 71 CR#1 --t CR#B -ER#10 r -- 42'' FF r =,�> _- _ .----_._-_.__- i z IG I IG A' l 1( 1I P I �\ 6 -- " 19 DEDICATED CIRCUIT FOR CASH REGISTER AND CARD READER. ®� a11-) ALL CR' CIRCUITS ARE ISOLATED GROUND. < ad G##8,10 THIS RECEPTACLE IS DEDICATED TO THE WORK ROOM W W_ �o FREEZER. CONFIRM LOCATION WITH FINAL FIXTURE PLAN. �a +42 1 18 NOTES: "� 1--- - - - i I , _ 21 DATA JACK FOR FUTURE NETWORK CONNECTION FOR ENERGY I ,I MANAGEMENT SYSTEM (EMS) TIE-IN (AT EMS PANEL). SEE 1. ALL DEVICES IN THIS DETAIL ARE MOUNTED AT __6j 02/E2.3. V-6"AFF EXCEPT WHERE NOTED OTHERWISE. I ...__� - Di8niiuurioN: WE: I I I � _1 0#22 i 22 DEDICATED RECEPTACLE AT 9'-0"AFF. 25% REVIEW 07/19/04 \ - I G�8„ I 23 SINGLE GANG JUNCTION BOX WITH 3/4' CONDUIT TO BAR JOIST 75/o REVIEW 07/28/04 0 -- LARGE SCALE OFFICE PLAN 09 �42"� ❑ +42- { ----- - - - FOR SECURITY SYSTEM INSTALLER'S USE. --T-�_- --- PANELBOA�D I ' - - ___ _ _�L -�^ -w p _.___� F 98% REVIEW 08/06/04 �AQ##1 - REF.: 02/E2.2,02/E2.3 1/4"=1'-0" I �+ _==_-_ 1L---_w- -- f .---�� L_._.__- ❑\ I I ----_ I 24 COORDINATE LOCATION OF THIS ELECTRIC PANELBOARD WITH PERMIT 08/13/04 24 I + 8„ PROVISIONS FOR OTHER TRADES, SUCH AS WOOD BLOCKING G 2 I FOR GENERAL CONTRACTOR'S USE. / ' 1 \ ADDENDUM #1 08/19/04 ACCUSTAT FOR BIRD ROOM. LOW VOLTAGE CONTROL WIRING SHALL BE FISHED - - - I DOWN IN WINDOW, NO EXPOSED WIRING OR CONDUIT PERMITTED. SEE DETAIL 2 ADDENDUM #2 10/20/04 2 -G2L-- WOMEN'S AQ#3 =� I /� __-rrr 11CLOSET �\ "- AQ#27 i I I C `� I MEWS `A-r�CAGE ROOV GFI +44 109 l I , , 1 j 1 \ - - - - - --- - ----- - -_ - - -_- - ___ - - - -- - - - _. _.. - - -- - - ---- --- t - ISO ROOM /' 02 ! 3#20,22I 117 !, \ +TUB ROOM WORK ROOM 118 1%ii�%I �.� i I%j�!% -} c GROOMING _ --- I I 17 I,� _ i�! i ' SALON ❑ I CLOSET �!'' — - - = -- --- i,:, I I �\ 120 -�. % ;I - = .` -\ 1� -t 107 17 12 I %' !�i l - %i GROOMING DP#3,7,39,41! I I I BREAK RM _ _ 112 r I , - RECEPTION - -- - -- - - - - --- - I J�. / OQ, ( �1 104 HEI JOB a PETCO P.m. JUIi t1 _ :� VESTIBULE 110 - - 101 0450000526 PRE -SALES �; - E3.2 ' _ _-_ = - 17' _ -- - _ __ -� DRAWN: CHECKED: \ \► E3.2 1 - ' AQUARIUM G#22 I 116 j ! i AREA ALR BJT /Ax 25 115 04 , !,', OFFICE _ -- i I t E3.2 113 DRAWING ME- ELECTRICAL u LARGE SCALE PLANS E392 AND DETAILS LARGE SCALE BATHROOM AREA PLAN 05 LARGE SCALE BIRD ROOM PLAN 04 LARGE SCALE GROOMING AREA PLAN 02 KEY PLAN 01 REF.: 02/E2.2 1/4"=1'-0" REF.: 02/E2.2 1/4"=1'-0" REF.: 02/E2.2 1/4"=V-0" REF.: NO SCALE E3.2 C C_ AC- A/ I I I I I I I I I I I 21 U-7 1-0 I SfI1VF'ORD FIRE DE PAR 1'MENT FAZE PLtEVENTION DI VISION 300 N. Park Ave., Sauford, Ft. 32771 / P. O. Box 1788, Sanford, Ft. 32772 (407 302-2520 /FAA' (407) 302-2526 Plans Review Sheet Date: October 22, 2004 Business Address: 2201 W.P. .Bell Blvcl. Oce. Ch. 36, 11Nlerecintile Class `B' Business Name: PetCO Store Ph. (770) 394-1G16 FAX (770)39z1-1314 Architect: Phillips Partnership PH (770) 394-1 G 16 Fax. (770) 394-1314 Contractor: T.B.A. (out to bid at time of subrnittat) Reviewed with coinme t Plea Reviewed by: Timothy Robles, Fire Protection Inspector/Plans Examiner Pli. ( ) Comment: Plans reviewed as Mercantile Occupancy. FD reserves right to require applicable code requirements if occupancy use changes. Sprinkler plans to be submitted for review, permitting, and inspections. Sealed letter loom Engineer of Record stating design criteria for sprinkler system needs to be submitted with construction plans. Separate permit required for Fire Alarm. 1.1 Fire Alarm requirecl for monitoring of 'sprinhler system 1.2Application — New Building (.15,359 s. q. ft.) 1.3 Nlised — N/A, all restaurants under 50 occupancy load 1.'1Special Definitions — Class "B" Mercantile Store (Under 30,000 sq ft.) t.50assification of Occupancy— Mercantile Store Class "B" 1.6 Classification of Hazard of Contents — Ordinary in office areas, and storage area classified as "High Hazard" per L.S.C. 101 1.7 I'linimum Construetiotl — Shalt comply with Florida Building Code 2001 mercantile occupancy Type IV, UNPROTECTED SANFORD FIRE DEPARTIYIENT FIRE PREVEN11ON DIVISION 300 N. Park Ave., Sanford, FL 32771 / P. O. Box 1788, Sanford, Ff. 32772 (407302-2520/FAX (407) 302 2526 1.8 2.2 Means of Egress Components — Rear �I1Xf`I SHA[ L I3E DILINI✓� IET�: WITH 44,, el�io�y paint on floor` lading to EXIT cloar 2.3 Capacity of Egress — sales floor area based on one (1)_ person per 30 sq ft., storage area based on one (1) person per 300 sq. ft. 2.4 Number of Exits — (Minimal of three (3) required GXtTS 2.5 Arrangement of Egress: Travel clistance increased up to 200' (fl) do to fire sprinkler system 77 j tE d !F i<<,14i 2.6 Travel Distance — Rear'EXIT SHALL F3E' DILINLA I'LD W111141 fellow p�tmt oii.;Ilooi' leacl`to EXI I door? 2.7 Discharge from Exits — O.K., will field verify 2.8 illumination of Meaus of Egress —additional EXIT SIGNS may be required (bower shut clown test required at night only) 2.9 Emergency Lighting— (1) foot candle (10 lx & a minimum at any point of 0.1 foot-candle (1LX) measured along the path of egress at floor level. Therefore additional emergency lights may be required, (power shut clown test required at night only) Enterl4ency Lighting required inside Main Electrical room and all rest rooms (Y). 2.10 1Ylarking of Means of Egress — O.K.; will field verify? 2.11 Special Features —Reserved 31 Protection of Vertical Openings — Class (B) mercantile shall have cin cultomatic ire sprinkler system, design cr-iterict SHALL SHOW storage rnoximum hei ht in storage area M. 3.2 Protection from Hazards — (See exception 36-3.2.1 .LSC 101) 3.3 Interior Finish — Not requirect, building has an aUtornatic fire sprinkler system 3.4 Detection, Alarm and Communications System: (as per N.F.PA..72- 3-8.3.1.2 (99) Ed. • 3.5 Extinguishing Requiremetits — crs per NFI',,1 10, tour- L4) fine extinguishers rec/itired der N.F.P.11... 910 See blue prints (Minimal 4A 60 B.C. Rated) (*). 2 SANFORU FIRE DEPAR EVIENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Ft. 32771 / P. O. Box 1788, Sanford, Ft. 32772 (407 302-2520 /11AX (407) 302-2526 5.1 Utilities — as per LSC 7-1 5.211VAC — as per LSC 7-2 5.3 Elevators, Escalators, Conveyors (4A-47) — N/A Sanford City Code — Chapter9: Required; Fire Spriilklers. Fire Department will field verify sight glass at all inspectors test. A,lonitoring: Reduir•ecl for• fire sprinkler system and all inside and outside fire sprinkler valves. Other: N.FPA 1 3-5.1 Fire Lanes — Required if building is more than t 50' from street; exception: building leas fire sprinkler system. 3-6.1 ley Box — One (1,) required see application attached 3-7.1 Bldg. Address Number Posted and Legible — Post address in 6" six inch numbers contrasting in color (see blue prink). - _ - i �� yam. ,. J 9Tf:�• i £��Y, ,•Af z ARCH. DWG. ABBREVIATIONS AND SYMBOLS PROJECT TEAM SITE KEY PLAN a L ANGLE MEMB. MEMBRANE LANDLORD: OCT 700 W ® AT MET. METAL RAMCO GERSHENSON,INC w CENTERLINE MFR. MANUFACTURER 27600 NORTHWESTERN HWY, SUITE 200 I # POUND OR NUMBER MIN. MINIMUM SOUTHFIELD, MICHIGAN 48034 F� z ACT. ACOUSTICAL CEILING TILE MISC. MISCELLANEOUS SOUTH MIAMI, FLORIDA 33143-5161 re ,y r"rcr • r+.� •.c,,,,,,u O aw •t ADJ. ADJUSTABLE M.O. MASONRY OPENING e jg(t`Mrc 5 �1Is 5 Jr -= b - +� F.,Y -! y.-,-•-.,,..."".. I:XUYJJY^FY4 fW • S ® ® -" j€ .«y-•. .. _ W AL ALUMINUM M.R. MOISTURE RESISTANT 4 ii f 5 4 APPROX. APPROXIMATE MTD. MOUNTED TENANT OWNER IN FEE) V� �=" - - -� d y -��_ j ARCH, ARCHITECTURAL N. NORTH � I tJ1 j Q ASPH. ASPHALT PETCO Animal Supplies Inc. r YY HG1uuFrc� i .••----.•„� N.I.C. NOT IN CONTRACT 9125 Rehco Road _ s ...._... ,f Fri Ir.ru,.n B.C. BACK OF CURB NUMBER f JT O N0. B R San Diego, CA 92121 II BD. BOARD NOM. NOMINAL F �, !''/ fa BITUM, BITUMINOUS (858) 677-3007 I €� W N.T.S. NOT TO SCALE nl Jam.. $ - , '` �..:........_ a S, e � �'RD T BLDG. BUILDING Contact: CYNDI PRUZINSKY, PROJECT MANAGER � •� -�=f ;° � �, I- BLK. BLOCK O.A. OVERALL OBS. OBSCURE i f Z BM. BEAM " - Q.C. ON CENTER J ��,..••�� .+_•€ f t,,.,r.l!M iu B.Q. BOTTOM OF�fWl�ta i! I R O.D. OUTSIDE DIMENSION r /I I 0 CAB. CABINET ARCHITECT (TENANT IMPROVEMENT) �r°� ��S['pAY 1_ 0 O.G. OPAQUE GLAZING CEM. CEMENT SBLM ARCHITECTS �'•� X'y`•° - p "�r, �'" i ; " ", d CER. CERAMIC O.H. OVERHANG 151 WEST 26TH STREET¢ U OPNG. OPENING ---_----_ ...... I- C.I. CAST IRON NEW YORK NY 10001 OPP. OPPOSITE + f 0 C.F. COLD FORMED PRCST. PRE -CAST (305) 412-9187�._ *, .0 °, •„ . 4 C.G. CORNER GUARD PL PLATE Contact: MAURICIO RODRIGUEZ, Project Manager t � 8 i .•.., � j' ` /u �`-< � C.J. CONTROL JOINT � P. LAM. PLASTIC LAMINATE � �,,•,.•., �" j� ""���'•„ � � � � i O CLG. CEILING PLAS. PLASTER CLxG. CAULKING PLYWD. PLYWOOD VICINITY MAP z CLR. CLEAR P.O.C. POINT OF CONNECTION MECHANICAL/PLUMBING cMu CONCRETE MASONRY UNIT PR. PAIR ELECTRICAL ENGINEER ,TENANT IMPROVEMENTS 4 CASED OPENING PR. TR. PRESSURE TREATED W In COL. COLUMN P.S.F.F. PREFAB. STRUC. STL FABR, HENDERSON ENGINEERS I- w g U CONC. CONCRETE PT. POINT 8325 LENEXA DRIVE, SUITE 400 fit+twfGfWAY �gllY CONN. CONNECTION PTU• PAINTED LENEXA KS 66214 b,bYa W a 913 307- 5300 � 1L CONST, CONSTRUCTION Q.T. QUARRY TILE ( ) 0 w Contact: RANDY NELSON, Project Manager >rl`1TRAtJG r' N vYl:ab;, rr.a U � CONT. CONTINUOUS R. RISER n Wlt yIYYYynIM4NYYYAYYaI fIx yrlyWwti4iiwYY U) CORR. CORRIDOR RAD. RADIUS Q p CTSK. COUNTERSUNK R.D. ROOF DRAIN j / TENANT IMPROVEMENT F O R (,/ C�✓ _ CNTR. COUNTER REF. REFERENCE Z Z �� � Q C.T. CERAMIC TILE REFR. REFRIGERATOR �%� � L- CTR. CENTER REINF REINFORCED > `� if A NEW P�aTCO STORE � 0 READ REQUIRED � � � � °� U D DEPTH %� �YYaYahnlrl 0 W DBL. DOUBLE RESIL. RESILIENT / U 1- DEPT. DEPARTMENT RET. RETAINING 0 �' RM. ROOM 11 S A N F O R® FLORIDA" z U D.F. DRINKING FOUNTAIN I Q DET. DETAIL R.O. ROUGH OPENING - (J x w DIA. DIAMETER R.T.U. HVAC UNIT au�..... TO W N E CENTER B LV D & W.P. BALL B LV D W DIM. DIMENSION RWC RAINWATER CONDUCTORannbowba U DISP. DISPENSER S. SOUTH W SEMINOLE COUNTY � - DN. DOWN S.C. SOLID CORE �' ,f I ] 0 D.O. DOOR OPENING SCHED. SCHEDULED - z DR. DOOR SHT. SHEET "y aowwuwnYYYwYw DWR. DRAWER S.J. SAWCUT JOINT t� SAN F O R D FLORIDA J )' LJ I (0 Il DS. DOWNSPOUT SIM. SIMILAR � to Q DWG. DRAWING SPEC. SPECIFICATION }} a aE. EAST SPECD. SPECIFIED (SECTION) J EA. EACH s.sT. STAINLESS STEEL CURRENT ISSUE D RAW I N G S EJ.F.S. EXTERIOR INSUL & FINISH SYSTEM STD. STANDARD CODE DATA E.J. EXPANSION JOINT STI_ STEEL SHEET DRAWING TITLE CURRENT ISSUE DATE ISSUED z p EL ELEVATION STOR. STORAGE 2001 FLORIDA STATE BUILDING CODE 0 ELEC. ELECTRICAL STRUC. STRUCTURAL 2001 FLORIDA STATE PLUMBING CODE: A0.1 Code Data, Project Data PERMIT 8/13/04 AO.2 PETCO Vendor Contractor Furnished Items PERMIT 8/13/04 * EMER. EMERGENCY SUSP. SUSPENDED ® Group: ® Egress Width: Required Provided * MINIMUM PLUMBING FIXTURES : / ENCL ENCLOSURE T.C. TOP OF CURB _ A1.1 NOT USED EQ, EQUAL TEL. TELEPHONE M (Retail) 454 X 0.2 in. = 90.8 in. MERCANTILE 15, 012 S.F. TOTAL OCCUPANT LOAD = 480 PERSONS A1.2 Demolition Plan PERMIT 8/13/04 EQPL EQUIPMENT 0 Building Shell Type of Construction: M Stock T&G TONGUE AND GROOVE ( 2 X 0.2 In. = 0.4 in. E.W.C. FIECTRIC WATER COOLER T.G. TEMPERED GLASS IV M (Grooming) 24 X 0.2 in. = 4.8 in. 0 WATER CLOSETS A1.3 Building Shell Verification Plan (Exhibit B) PERMIT 8/13/04 EXST. EXISTING T.G./SP. TEMPERED SPANDREL GLASS 96 IN. 147' 1 EA. SEX PER 500 PERSONS Mgg Female A2.1 Floor Plan, Floor Finish, and Partition Notes PERMIT 8/13/04 EXPO. EXPOSED T.I.G. TEMPERED INSULATING GLASS *Allowable areas (with Fully Sprinklered System): ® Number of Exits: REQUIRED 1 1 A2.2 Store Fixture Plan PERMIT 8/13/04 EXP, EXPANSION THK• THICK Required Provided Allowable Building Area: Actual Building Area: PROVIDED 1 1 A2.3 Reflected Ceiling Plan PERMIT 8/13/04 M Uq M 12, 828 SF EXT, EXTERIOR T.O. TOP OF Group M (RETAIL) 2 2 g FABR. FABRICATOR/ FABRICATED Group M (STOCK) 1 1 0 Lavatories A2.4 Roof Plan PERMIT 8/13/04 T.P. TOP of PAVEMENT F.C. FURRING CHANNEL TS TUBE STEEL *Fire Separation Assembly Between Group M Tenants, with Group M (GROOMING) 1 1 1 EA. SEX PER 750 PERSONS Male Female A3.1 Door Finish Schedules, Door & Storefront Types PERMIT 8/13/04 F.D. FLOOR DRAIN TV TELEVISION exception for Fully Sprinklered System: 1 HOUR REQUIRED 1 1 A4.1 Exterior Elevation PERMIT 8/13/04 FDN. FOUNDATION T.W. TOP OF WALL *Occupant Load Gross F.E. FIRE EXTINGUISHER e®ACCESSIBLE MEANS OF EGRESS PROVIDED 1 1 A5.1 Partial Exterior Elevation, Interior Wall Sections PERMIT 8/13/04 TYP. TYPICAL M (Retail) 13 614 S.F. 30 S.F./P.P. = 454 PERSONS F.E.C. FIRE EXTINGUISHER CABINET REQUIRED: 2 10 Drinking Fountain A5.2 Exterior Wall Sections PERMIT 8/13/04 FIN. FINISH UNF. UNFINISHED M Stack) 674 S.F. 300 S.F./P.P. = 2 PERSONS PROVIDED: 2 U.G.UNDERGROUND M Grooming) 724 S.F. 30 S.F./P.P. = 24 PERSONS 1 PER 1000 PERSONS Fixtures A6.1 Exterior Details PERMIT 8/13/04 FIXT. FIXTURE REQUIRED FL. FLOOR U.O.N. UNLESS OTHERWISE NOTED Occupant Load = 480 PERSONS PROVIDED 2 A7.1 Large Scale Plans PERMIT 8/13/04 FLASH. FLASHING UR. URINAL FLUOR. FLUORESCENT VCT VINYL COMPOSITION TILE 0 SERVICE SINK A8.1 Interior Details PERMIT 8/13/04 vERT. VERTICAL 33.5 REQUIRED A8.2 Interior Details PERMIT 8/13/04 F.O.C. FACE OF CONCRETE EGRESS EXISTING TENANT DEMISING WALLS TO 1 F.O.F. FACE OF FINISH VEST. VESTIBULE REMAIN PROVIDED 1 A9.1 Interior Elevations PERMIT 8/13/04 F.O.M. FACE OF MASONRY W. WEST WIDTH A9.2 Interior Elevations PERMIT 8/13/04 F.O.S. FACE OF STUDS W/ WITH © GROUP M a>=. FRMG. FRAMING WD WOOD v PME1.1 Plumbing / Mechanical / Electrical General Information PERMIT 8/13/04 FR. TR. ARE RETARDANT TREATED W/o WITHOUT FAT (GROOMING) P1.1 Plumbing General Information & Schedules PERMIT 8/13/04 FT. FOOT OR FEET WP WATERPROOF FTG. FOOTING WSCT. WAINSCOT ° P2.1 Plumbing Plan PERMIT 8/13/04 FURR. FURRING GENERAL NOTES REGARDING THIS PROJECT: WT. WEIGHT P3.1 Plumbing Large Scale Plans & Details PERMIT 8/13/04 GA. GALVANIZED o 1. Refer to Drawing A2.2 for retail store fixture layout GL GLASS � COLUMN LINE ��.../ P3.2 Plumbing Large Scale Plans &Details PERMIT 8/13/04 GR. GRADE 2. Egress widths shown on "Code Data' diagram are P4.1 Plumbing Riser Diagrams & Details PERMIT 8/13/04 GYP. GYPSUM for automatic sliding entrance doors with breakout GYP BD. GYPSUM WALLBOARD X doors/ panels. M1,1 Mechanical General Information & Schedules PERMIT 8/13/04 OOR H.B. HOSE BIBB DETAIL/DWG. o p o SLIDINGD A1.1 M2.1 Mechanical Plan PERMIT 8/13/04 H.C. HOLLOW CORE WITH BREAK 3. EXISTING MERCANTILE USE BUILDING. M3.1 Mechanical Large Scale Plans & Details PERMIT 8/13/04 N.D. HEAVY DUTY 0.0UT_80,� n HDWD HARDWOOD X ELEVATION/DWG. M3.2 Mechanical Details PERMIT 8/13/04 HDWE HARDWARE A4.1 BLDG. SECTION/DWG, 4, All Wood and Plywood Blocking used in Tenant F1.1 Fire Suppression System General Information & Details PERMIT 8/13/04 Space Partitions shall be fire retardant treated. ppress�em H.M. HOLLOW METAL GROUP M E1.1 Electrical General Information & Schedules PERMIT 8/13/04 HORIZ. HORIZONTAL X WALL SECTION/DWG. (RETAIL) I STORE FIXTURE DATA REGARDING THIS PROJECT: E1.2A Panel Schedules PERMIT 8/13/04 HR. HOUR A5.1 DETAIL/DWG. P HGL HEIGHT --- 0 1. The highest store fixture for merchandise E1.213 Panel Schedules PERMIT 8/13/04 HSS HOLLOW STEEL SECTION +0'-0" o 0 0 (racking) for this project is no more than 10 feet E1.3 Electrical Single Line Diagram and Details PERMIT 8/13/04 I.D. INSIDE DIMENSION ELEVATION height to the top of store fixture. I.G. INSULATED, CLASS FIN FL E2.1 Electrical Lighting Plan PERMIT 8/13/04 R VB1 2. The highest that merchandise will be stored in INSUL INSULATION FINISH E2.2 Electrical Power Plan PERMIT 8/13/04 retail or receiving/stock areas is less than 12 y PERMIT 8/13/04 INT. INTERIOR feet height to the top of merchandise. E2.3 Sound and Communication System JAN. JANITOR F-X STOREFRONT TYPE E2.4 Security System Plan PERMIT 8/13/04 JT. JOINT PX PARTITION TYPE 0 E3.1 Electrical Large Scale Plans, Details PERMIT 8/13/04 KIT. KITCHEN LENGTH RETAIL ROOM &NUMBER GROUP M ° E3.2 Electrical Large Scale Plans, Details PERMIT 8/13/04 L. 0 LAM. LAMINATE XXX �� EMS1.1 Energy Management System Information & Details PERMIT 8/13/04 LT. XX DOOR NUMBER (STOCK) " � LAVATORY ° M LIGHT 6 FE FIRE EXTINGUISHER r _ MAX. MAXIMUM (xxxxx) REFER TO PROJECT MANUAL EXISTING TENANT DEMISING WALLS TO- MECH. MECHANICAL SECTION NOTED REMAIN anforcl +ire'revenf (on IV, )ntQ 0 c l9 Q> +' O 00 J v� wcTv- i9ZL Im i ix c ( E } 0- N , r N X € o a> cu 5 to Z F L %k Architect: 'James Cohen License #: 0015903 a J Lrl J J m 2 J O m�o 0 �w::)o u CL < W OI WW _J LL W Z) 0 LLt O1 O ILL �F_ W.OWQ a F-• (1) (n F 0 m 9 S � Id 0 p N� a GO DISTRIBUTION: DATE: PERMIT 08/13/04 SBLM JOBN PETCO P.M. JOB N DRAWN: CHECKED. DRAWING TITLE: CODE DATA ' PROJECT DATA s— .-- _ -_ ! Z W U) W F- Z 0 W J a F- W 0 Y X 0 3 W F- (9 Z 0 > 0a a 0 0 a I V) Z 0 Z W 2 Q I-- w U w z ft Q (Ya oW UQ� O (UA a ° (1)} ZZ a oLL _o o[- Z () ow T ZU P U)a x W l!! � �� wF- >0 J Z J } a J za U)o a0� a o-j �< zo 0¢ i ITEM DESCRIPTION PETCO VENDOR/ PETCO CONTRACTOR RESPONSIBILITIES i CONTRACTOR RESPONSIBILITIES . �u _ y Ke 1 1National Account or Y Labor Furnished B Contractor Materials Furnished B PETCO Vendor Labor Furnished By PETCO Vendor f Materials Furnished by Contractor I y Item Description Cade Location Reference :INVENTORY Agreement Y --..-..-.•.----.-_--.-_......._.-__...-......._.__..---- ..---------- - — . — .._..__-....__- _-_... - - - i __ ... - _ - - - _ - ..... ---- __....-•--_ - -- -- - - ---------- - --- -. -- _ ._ -- -----------T - . _ �- - -- - - ___..-...._.._ .--_----..--.---•4--- ---- __ -- - - 1 utomatic Slidin Entrance Doors - I Exterior 101 08410 1 - None None Automatic Sliding Entrance Doors, Electrical provisions Installation, Final Elec. Connections 11 A ........................................................................................................................................................................._-...-•-_-._..._._._..._-._....__-................_......._.........................._................................................................................................................................................................... 9 �..................... I 2 Banner Anchors - Exterior 05500 - :None None All Materials All Labor -_______ __ _______......._. I -._z .__...........---.._.........__......_............._._..__.-._.....___._......_...—........................_...._._ -------••-•------.--...._.__...----......-._....._.._._........__....._______-......._._...................._-....._..__...... __.._......._.._ __ _ _ _ __ ................. - _ _ _........ ---- _ .. ._ . - 3 Building Exterior Si na e - Exterior 10400 i National Account : Building Exterior Signage Installation : Structural Substrate, Power Supply Sealant work after signage installation 3 9 9 9................................................................................................................................................................................................._.._._.._..._.......__.._ ... _.._...._._.__.._..__......................................_...................................................._.......................................................................................................................................... _....................................................................._.._.. _..._.._.. _._...... ---........................................................_...........................................__......................................................................................................_...._...................._.......... I 1. 104,107,109,111,112, 4 Cabinets, Countertops, Coat Racks, Shelves - 113115116120 06200, 08710 i - None None Cabinets, Countertops, Shelves, Coat Rack, concealed blkg. Installation - - - i 4 -----------_.____._.._..__..._.._.._.._._-------------------•-----_.---------'---- >_......_.....__.. __._.._._.__..---- ; .-.._-.--...._.........-......._._.-. ......-.-......._._.._......_ ....._.-_ ......._..____._.—.._...__--___._...—._....._._.....� ......------ 3 I II Labor = 5 5 Cart Corral - f Exterior, Interior 10300 - i None None All Materials A_.............._.................................................................................................................................................................... .............;..................................................................-....................................................................................................................................-...-.........._............._.................__...__.._..-----._...............-._..............................................._..........................................................._.........................................................---...........................................................................................................................................................................................................................................................................................................................................................................................___........._.-_...._.......__...._................._..........__............................................ . ,. ; ii 6 Cash Register (POS) System - Per Drawings 16000- i National Account :Cash Register (POS) System Installation - --- _ Conduit, boxes, pullstrings I Electrical Provisions i 6 ec 'c o 'sions `7 7 Computer Equipment - 120 A2.3, 10300 : National Account i Computer Equipment Assembly, Installation, Final elec. connections Conduit, box, power supply EI tri al pr vi Pi _._.........: _..._...__..... ............._._._.._................_.................................................................................................................................................................................................I.............. 8 Employee Time Clock - 120 E2.3 National Account I Employee Time Clock Installation ; Conduit, boxes, pullstrings, power supply I Electrical provisions 8 -� Ener Mana ement S tem EMS ` 9 Energy Management System - 1 118 16600 National Account • Energy g Programming, System Startup Conduit, boxes, wiring, power supply -- Installation of EMS, Final Elec. Connections -�-_- - -- -- 19 ---- _ _ _ .._.................._.... _......_ -- ._._ _.__._ _ -.___ _ _ .........:.- --- _..__ . _ - _.._�.� :Devices Wire -_ -- ------ - .._.._.. --- __ ----- .__ _ _ _ _._............ _ _ -_ _-- - ..._---___ _ __ . _ - ---- ---- - ..I.._ -r- _-- - - E _ Entrance ce Floor Mat I In stallation 110 10 Entrance Floor Mat 1101 A2.1, 10300 :None None 1 I I................_...............................................................................................................................................................................................................................................'.............. ...................................................................................................................................................................................................:...................................................................... r ..............__....................---........................................-..............................................................................................................................................................................................................................................................................................................................................................................--..............._._...._._........ , 11 Fire Alarm & Security System - Per Drawings 16000 i National Account Devices, Wiring Installation P 9 + P supply Final Elec. Connections - - - - : 11 • { 1 Conduit, boxes, ullstrin s ower su __ _...___--__.-_.-.-...__ _ _ _ _-__ _____ ___..._.____ __ _ ___....__..___..-.- __ —_ -„ -- ___ -- _ _ _.......-----_---__ ___._........------------ - _ ._.......-_--- _ : _..__ 12 Fire Extinguishers - € Per Drawings 10300 ! - i None None 3 Fire Extinguishers, brackets, signage Installation 1 12 9 9_................................................................................................................................................................................................................................................................................................................................................................................................___...._...........__....._.._..._............................_....._..............................................................................................................................................................................................................................:............... I..............................................._.............__..........___..__..._.......:_--•.--•--•-----..........._-........................................._._...._....---------.....--•---............................................................................................-...-........................................._... . .................................................................................................................... : 13 Grooming Reception Counter - 104 A2.1, 10300 National Account : Grooming Counter & Swing Door Delivery, Offloading Installation - - _ -- - _ _ None-- None i 13 --- i 14 Hitching Rings _ - 104,105,106,107 05500 - : None None Hitching rings, concealed blocking !Installation 1 14 9 9 ...............•......................................................................................................................................................................................................_..._•--•-__.._.._: _...................................._....................................................................................................................................................................................................................................:.............. ...............................................................................................................................__........._._..._..............................__.;__...................__....._... - _._.._..._._.......... ---.............................................................................................._......................................................................................................................................................................................................... . 15 HVAC Rooftop Units (RTUs) - Rooftop 15500 1 INVENTORY Agreement i None None i Structural provisions, RTUs Installation, Roof Flashings 15 _-.....__..._....— i I I None None E 16 _ Installation Interior Graphics atio al Account Int ri 16 Interior PETCO Store Graphics 102 10300 N n p ....... __..........._........_..............................__.................................................................................................................................................................................................�............... P 17 Light Fixtures & Lamps - Per Drawings 16000 I INVENTORY Agreement i None None General/Night/Emergency/ Light Fixtures &Lamps Installation, Finai Elec. Connections 17 18 LoadingDock Equipment - Per Drawings 10300 INVENTORY Agreement None None -- Loading Dock Equipment Installation _ �- 18 -.------._... ------......_...................- - ___ _ _ - _� _-...__._..._...._....._..._-..........--------... _ - --__-------- - Installation I 9 irrors 1 Mi 19 Mirrors 106, 109, 111 08800 : :None None i : 1.............................................................................................................................................................................................._ .__...._......._....... _....._._........_.._...._....._.............................__................................................................................................................................................................................................:............... ........................................:............................................._---__._..._.._.._-.__-...-..._..__...._..____.---......................................._._..-...-----•---................................................................................_.._. 20 Pylon Signage (if appl.) - : Site 10400 National Account : Pylon Signage Installation Foundation, Bolts, Conduit and power supply Final Elec. Connections - 20 _ ____..___..}.__..._ _._----------___....__ __ ___- _: _ _..... - ___-- ---------_-----_-.--...-_...____-_-__-____-___.------_.--__...-._....-----._-_-__._.,.___..____-_._____-____-_.-_-_-._-_.-._--.._.....____.._.._---__..._--_.. ---_-....-_--�....... ---------.--------------._....._..._.....--- - - _ ..-_ _ _ C is Cart Bum ers - 21 De fiver s all Sho in ur s I In t Carts Cart Bum er i u � Sho in , i National Acco nt D s 10300 P Bumpers Per Drawings Y PP 9 Carts, Cart Bum , PP 9 P 21 Shopping r 9 � ! PP 9 P .............................................................................................................................._................. j...__...............................................................................................................-............................................................................................................................................................................................................................................................... ..................................................................................................................................................................................................................................................................................................................... > i 22 Sound & Communication System - 1 Per Drawings 16000 National Account i Sound & Communication Eqmt., Devices, Wiring Installation - Conduit, boxes, pullstrings, power supply I Final Elec. Connections j 22 23 Store Safe - 120 10300 f National Account :Store Safe Delivery, Installation - - f 23 : - I ___ i ........ ............................................................!............................................................................................................................................................:.............................................._............._............_._.._........_._._---._._._...._...._.__................_......._.._......_......._............_.._......_................................_......... ........................................................................................................................................ . 24 Telephone System - 1 Per Drawings 16000 National Account : Telephone System Telephone System Installation, Final elec. connections Conduit Boxes, Pullstrings, Power Supply, Backboard Final Elec. Conne+,lions 24 __ _ - in 25 Toilet Partitions if a I. - 1 109,111 A2.1, 10150 -i - : None None Toilet Partitions, concealed blkg. Installat...n i 25 ( PP ....................................................................................................................................................................................................................................... ....... 26 Toilet Rm. &Other Rm. Accessories - 109,111,115,116,118 A7.1, A9.1 10300 National Account : Towel Disp., TIt.Tis. Disp•, Tlt. Seat Cov. Disp. Delivery - Balance of Accessories, Fasteners, concealed blkg. Install balance of accessories 26 r I ' 27 Wall Bumpers - 1 Per Drawing A7.1, 10300 INVENTORY Agreement � None None Wall Bumpers Installation -� --- M� i 27 ��._-. .-.___--.-..---_.........._...___-..__.__.-.......__..-__....-_.__._-__.-...-....-.-_._........._.._..._.___...._...._._......_......__ _._.._..___.._............___..__. _ _ _..._..___..__ _._.___ ._ __ _ - -___ _._____...__..---_________ __ - _ _ _..__.___ _. _ - _.__.___ .._._. _.._._....._._-._....__ . _._...._---_-----.-.-.--_ _...._ ___._ ._ - _.._..__.__ T Cor er uards Installation 8 Wall n n 2 one I N 9 28 Wall Cornerguards i Per Drawing A7.1, 1 0300 N one ! I 29 Window Shades - 102,104 A2.1, 10300 - i None None Installation 29 Window Shades __ ...__.._._....__- - _ _... __ ........_..-.__._.....-......_..................._----..._.. --------.... _------._ -.. _ _.._._..--- ... - ---- --_---------•---------•... ----_...__ ...-- ....... --,--..._•-_-- _ _ _.. ;__ ._. ._.__----.._-_-._-____-__...._.._....___••_--••-__.--_-.--- , .. _ _,- 30 Store Fix.: Aquarium Area Supply Room AQ1 I 119 A2.3, 10300 National Account 1 Freezer Delivery, Offloading, Installation i None 1 Node 1 30 PP Y............................................................................................................................................................................I................................................................................................................................................................................................. _...._.._..._ ...... __.._............................._........................._........................................._...................................................................................................................................................................... q_...._............____.........._........._.._.. - - -..............._............._......... -- ._........ --...._......................................................_........................__................_........._....._........._..........._................. . AQ2 119 A2.3, 1030(1 : National Account Plant Tank Delivery, Offloading, Instaliat on I None None I _._ i ovisioInstall Powe Poles Fi a b' & ec 'c Connections ower Pole Electrical Pr i i ns r Final Plumbing Electrical al sse b Installation P , De 'ver Offloadin A m i B in Station li, I Account a �9 AQ3 I 119 A2.3, 10300 1 National A I Bagging g Y 9 Y1 .....------.............................................................................................................................................................................................................................................................................................................................._...................................................................................._......................_._ _.__..._ _._._...........................__...._......................__-................................._..._...........................................................................................................................v.............. ,. AQ4 119 A2.3, 10300 i National Account Aquatic Tanks Delivery, Offloading, Assembly, Installation Plumbing, Elec. Provisions Final Plumbing &Electrical Connections 1 - "-Ai- ' AQ12 119 A2.3, 10300 National Account I Feeder Fish, Koi & Turtle Tanks Delivery, Offloading, Assembly, Installation __ Plumbing, Elec. Provisions Final Plumbing &Electrical Connections : I .........................................................................................................................................................................................................................................................................................................................................................................................................................._.----•---_-_•--._.........-........_-____-•--_..-.......................-----•--..-,-.................................................................-......................................-....................................................................................... •...........................................................................................................................-....................................-._.._._...._......._._.—.._._....._..r.....__..._..__—._..................................................._........._...............__.........................__.........._............................._. 4 i _......................................................................................................................._,...................................._........_......................__.._..... g AQ13 1 117 A2.3, 10300 - I None None -- --1 Sink Fittin Installation i : 31 Bird Habitat - 1 102 A2.3, 10300 - i Bird Habitat Delivery, Offloading, Installation of Habitat -- 1 Flooring, Acoustical Ceiling, Mech & Elec Provisions Flooring, Acoustical Ceiling, Mech & Elec Provisions 31 ._........_... ........._.--.._...-_...._.._-_......_._-_-.-.-...---____..........-._....._...._.._.-__..._._...-----•-____:_.....—•_--- _._. ..._.._.. i ..—__-_—....-•----- ..... .......-........._.._.........._._................-.-..--_-...--_-.. _.__ _........_. ...t...-..._.— None None i 32 oadi s allation ' e o Lockers Deliver Offl n In t ccou Refri rat r I National A nt A .3 10300 � 9 B 112 2 Y 32 ea Room R i 9 Store Fix.: Break St r :..................................................................................................................................................... ._... _............__. : 33 Store Fix.: Retail Area Check Lane CL # 102 A2.3, 10300 National Account Check Lane (Cash Wrap), Power Pole & Signs Delivery, Offloading, Installation 1 Electrical Provisions : Install Power Poles & Final Electrical Connections ---- 133 _ ._..._......_......._._.._ ._ -- _.----.. _..__.-.._._.._..._._ ......_-__.__ ........--.-.--_.-..-._-..-...-----.-._--.......--.__--^•_-' ...-......_.._...._............_..—___....__..-....._..._.._..._._.......—-....y_..._....._.. - - -. _. _.____r___..- __ _ . _ _ - ____ _ __._ _ __. _ . i None 3 i 0 o d' sse bl Installation I None N n 4 Deliver ffl a in A m s C a'rs able Etc. ' e Cabinet De k h i T 'o a Account Fil Nati n l 3 0300 � Y Office F 12 0 A2. 1 Y 9 34 General Furnishings/ s f i # I 9 / I .............. .................................................................}...................................................................................................................................... . i I 35 Store Fix.: Retail Area Gondola G # 102 A2.3, 10300 National Account Gondola Fixtures Delivery, Offloading, Installation Electrical Provisions i Final Electrical Connections 1 35 36 Store Fix.: Grooming Room - GR 104,105,106,107 A2.3, 10300 , National Account I Grooming Fixtures, Equipment Delivery, Offloading, Assembly, Installation : Electrical Provisions :Final Electrical Connections i 36 i 9...................................................................._..........._.._._..................-..._ _............. ...............-----................................_.._....................-----.._............................._.................................................................................................... .. GR 1 : 106 A2.3, 10300 National Account :Grooming Table Delivery, Offloading, Installation I None i None - -µ - GR 4 i 107 _ A2.3, 10300 i National Account i Cages Delivery, Offloading, Installation i Electrical Provisions Final Electrical Connections : ............................................................................................................................................................... . E i ................. _.._... _.._ _ ._............................................................................................................................................................................................_................................................................................................................................................................... ....-.._.-..---_..._.._.._......._...._.._......._...............................................-.......--.._....................................................................................................................................-...... ........ GR 6 i 107 A2.3, 10300 National Account : Washer, Dryer Delivery, Offloading, Installation i Plumb./Mech./Elec. Provisions Plumb./Mech./Elec. Provisions i GR 10 ; 104 A2.3, 10300 I National Account Grooming Reception Counter Delivery, Offloading, Installation : None 1 None - -��-- - ______ _ ____ ___ _- - _ - _ ---_.....-._--__-......-- -- I .. _ ___ _-..-..---..-..-..---_-------.__....-._----_-------..-..-..-...._--_..___.._-....__-_....-......-.._._-__..----..--.-__..--------__-------.-.._-..--_.._ I -. __ _ _ —_ _ _______ _� _ i € I. --..._.--._......__...._.-........_..........__...............-._......... ...---------------• i _ Re the Habitats Offloadin ,Installation I Mechanical & Electrical Provisions I Final Mech & Elec. Connections 37 e abitats Deliver co Re til H National Ac unt I 37 Store Fix.: RTL # i 102 A2.3, 10300 I p Y 9 , pp _...._.._ ....................... ........ ..._. ............ ..............................................................._................................................. ............. ._................................_.._................................................................................................................................................................................................................................................................................................................................................................................................................................._........_................................................_................._.........................................._............................................................................................................................................................................... b.............. _R_et.ail...._Area....................................................................................................................................:.......................................................................................................................{...........................................-.._.._._._.._ .-.....__ ................_4._. Small Animal Habitats I I Final Mech & Elec. Connections 38 38 Store Fix.: SA # i 102 A2.3, 10300 1 National Account i Small Animal Habitats Delivery, Offloading, Installation Mechanical &Electrical Provisions _ _ _.._- _ _..Retail Area---..._...-.. _ _------ __._._ - _ --.--.----- I _. s lat'on I None None E 39 Delve 0 oadin Assembl In tal i 39 Store Fix.: Retail Area SF # 1102 A2.3, 10300 : National Account i Litter Bin, Dog Bar, Cat Bar i ry, ffl g, y, ......--......-..............................._...------...-... _...-- _-_..........................................................__._._...._.....................-.-.._......................._._................._.......__........................... - - _...........--..._........................................................................................................................................................................................................................................................................................................................................................................................................................_............. -.---- ----.._......................._....-----........................................._........................................................................................................................................................................... SF4 : 1102 A2.3, 10300 National Account Store Fixture Delivery, Offloading, Installation Power Pole & Electrical Provisions I Final Electrical Connections SF18_.._._-.._ _- ___ _ _ _ W # : 102 A2.3, 10300 National Account :Wall Fixture Delivery, Offloading, Installation None i None F C O ch c m 0 v o LP o CD T ((J •*U w L- + J -"' }' -Co, U � � (V N, E (0 Z N In O _ a,): a) � }. � r-- rn 3 T N s Lo (D W tq F-- Z IL Architect: Jarhes--ec License #: 0015903 Ci ov J Q■ J Q U m o- _ Z (f) �> QW 0 j�< ®-J z w�0 Q., Q t-- O -j [--- (n , Z U � w w - W:D Ovw-2 O a- (/)0 Lu z z w - 0 Q F- (n a) 00 1 0 0 VN rd a z Er 0 8� U 0 U W W O1 U n:- 4 Z N '- Q DISTRIBUTION: DATE: PERMI ( 08/13/04 SBLLM JOBIt PETCO P.M. JOB N v �0 n DRAWN: CHECKED: MAWINQ ME PETCO VENDOR / CONTRACTOR RESPONSIBILITIES AO.2 rn O z_ ❑ w In w F- z w w Y tY 0 w C� z 0 > 0 01-1 O a 0 a z 0 z w w U cea OW U ry ❑ vUi a° U)} zQ oLL 0 Z 0w U �• z 0 �Q Xw Wz I-- U LL wo >z Q 2n �o oQ Z ❑ OQ • to R N R GENERAL DEMOLITION AND BUILDING PREPARATION NOTES: 1. DEMOLITION PLANS SHOW APPROXIMATE LAYOUT OF EXISTING BUILDING AND ARE NOT INTENDED TO REPRESENT "AS -BUILT" CONDITIONS. FOLLOW PROCEDURES OUTLINED IN SECTION 02060 FOR REQUIREMENTS TO VISIT SITE AND OTHERWISE BECOME FAMILIAR WITH ACTUAL CONDITIONS WHEN BIDDING THE WORK. 2. PRIOR TO ANY DEMOLITION WORK, CONTRACTOR MUST FIELD VERIFY ALL EXISTING MECHANICAL, PLUMBING AND ELECTRICAL WORK LOCATED IN THE TENANT SPACE WHICH AFFECTS THE ADJACENT TENANT SPACES. THE LANDLORD AND THE ADJACENT TENANTS MUST BE NOTIFIED PRIOR TO SHUTDOWN OF ANY SHARED MECHANICAL, PLUMBING AND ELECTRICAL SYSTEMS. 3. WALLS, PARTITIONS, DOORS, FRAMES, AND OTHER ITEMS TO BE REMOVED ARE SHOWN DASHED. SERVICES WITHIN WALLS AND PARTITIONS SHALL ALSO BE REMOVED. EDGES OF WALLS SHOWN TO REMAIN SHALL BE SAW CUT OR CLEANLY TOOTHED TO ACCEPT NEW CONSTRUCTION. REPAIR AND PATCH EXISTING WALLS SHOWN TO REMAIN WHERE INTERSECTING WALLS, DOORS, FRAMES, ETC. ARE SHOWN TO BE REMOVED AND WHERE EXISTING CONSTRUCTION WILL NOW BE EXPOSED IN THE NEW CONSTRUCTION. 4. EXISTING EXTERIOR WALL INSULATION SHALL BE LEFT IN PLACE OR SHALL BE REPLACED WITH NEW MATERIAL OF EQUAL INSULATING VALUE. Q ±17'-4" F :40)-- - — - — - — - ---------------I 1 0 49 r-1 J n VERIFY VERIFY VERIFY 5. EXISTING CONSTRUCTION SHOWN TO REMAIN INCLUDING BUT NOT LIMITED TO WALLS, PARTITIONS, DOORS, FRAMES, ETC. SHALL BE PROTECTED DURING DEMOLITION. DAMAGE TO EXISTING CONSTRUCTION SHOWN TO REMAIN SHALL BE RESTORED TO MATCH PRE -DAMAGED CONDITION AT NO ADDITIONAL COST. ALL SURFACES TO REMAIN ARE TO BE PREPARED AS REQ'D. FOR NEW FINISHES. COORD. WITH FINISH SCHEDULE. 6. PROTECT FROM DAMAGE ALL EXISTING FINISH WORK TO REMAIN IN PLACE AND WHICH BECOMES EXPOSED DURING DEMOLITION OPERATION. 7. PROVIDE ALL NECESSARY SHORING, BRACING, AND SUPPORT TO PREVENT MOVEMENT, SETTLEMENT, OR COLLAPSE OF STRUCTURE OR ELEMENT TO BE DEMOLISHED, AND ADJACENT STRUCTURE OR ELEMENT SHOWN TO REMAIN. SHORING AND BRACING SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER LICENSED IN 111E LOCAL JURISDICTION. 8. PROVIDE TEMPORARY WEATHER PROTECTION AND SECURITY DEVICES DURING INTERVAL BETWEEN DEMOLITION AND REMOVAL OF EXISTING CONSTRUCTION ON EXTERIOR SURFACES AND INSTALLATION OF NEW CONSTRUCTION TO ENSURE THAT NO WATER LEAKAGE OR DAMAGE OCCURS TO STRUCTURE OR TO INTERIOR AREAS OF EXISTING BUILDING. 9. EXISTING CONCRETE FLOOR SLABS, MASONRY WALLS AND EXISTING STRUCTURAL FRAMING SYSTEMS TO BE REMOVED SHALL BE CLEANLY SAWCUT FROM EXISTING CONSTRUCTION. COORDINATE ALL BELOW SLAB MEP WORK AND REQ'D. SLAB REMOVALS 'MTH CONTRACT DRAWINGS. PROVIDE SLAB CONSTRUCTION REPLACEMENT TO ALIGN WITH EXIST. E ±41'-1 1/2" 10. WHERE FINISHES ARE SHOWN TO BE REMOVED FROM EXISTING CONSTRUCTION, 14, REMOVE ALL EXISTING OBSOLETE PLUMBING, MECHANICAL, AND ELECTRICAL REPAIR AND PATCH REMAINING SUBSTRATE AND PREPARE FOR NEW FINISH. EQUIPMENT IN THEIR ENTIRETY THROUGHOUT TENANT SPACE PARTICULARLY CAREFULLY REPAIR AND PATCH ALL REMAINING SUBSTRATES THAT WERE WHERE EXISTING ITEMS WILL INTERFERE WITH THE INSTALLATION OF NEW ORIGINALLY CONCEALED BY EXISTING FINISHES, BUT WILL NOW BE EXPOSED IN CONSTRUCTION, OR WHERE EXISTING ITEMS WILL BE EXPOSED IN THE NEW THE NEW CONSTRUCTION. CONSTRUCTION, UNLESS SPECIFICALLY SHOWN ELSEWHERE IN THE CONTRACT DOCUMENTS TO REMAIN WITH MATERIALS MATCHING EXISTING CONSTRUCTION. 11. SALVAGE MATERIAL AS REQUIRED FOR PATCHING AND INFILL, SALVAGE COORDINATE WITH NEW CONSTRUCTION. MATERIAL SHALL BE CLEANED AND STORED IN AREAS AWAY FROM THE DEMOLITION OR UNTIL NEEDED. 15. REMOVE ALL EXISTING OBSOLETE BUILDING MOUNTED AND ROOF MOUNTED MECHANICAL, PLUMBING AND ELECTRICAL EQUIPMENT AND DEVICES IN THEIR 12. ALL INFILL OR REPLACEMENT WORK IS TO MATCH EXISTING CONDITIONS IN ENTIRETY FROM THE FRONT ELEVATION OF THE TENANT SPACE PARTICULARLY MATERIALS, CONSTRUCTION AND FINISH, UNLESS SPECIFICALLY NOTED WHERE EXISTING ITEMS WILL INTERFERE WITH THE INSTALLATION OF NEW ELSEWHERE IN THE CONSTRUCTION DOCUMENTS. CONSTRUCTION, UNLESS SPECIFICALLY SHOWN ELSEWHERE IN THE CONTRACT 13. REMOVE ALL EXISTING OBSOLETE MISCELLANEOUS NONLOADBEARING ITEMS IN DOCUMENTS TO REMAIN. REPAIR AND PATCH ALL SURFACES TO REMAIN WITH THEIR ENTIRETY THROUGHOUT TENANT SPACE ABOVE AND BELOW EXISTING MATERIALS MATCHING EXISTING CONSTRUCTION. COORDINATE WITH NEW CEILINGS, INCLUDING (BUT NOT LIMITED TO) PLASTER AND DRYWALL PARTITIONS, CONSTRUCTION. DOORS, FRAMES, SOFFITS, STUDS, FURRING, INSULATION, CEILING SUSPENSION 16. REMOVE ALL EXISTING OBSOLETE ROOF MOUNTED MECHANICAL, PLUMBING AND SYSTEMS, ETC. PARTICULARLY WHERE EXISTING ITEMS WILL INTERFERE WITH THE ELECTRICAL EQUIPMENT AND DEVICES IN THEIR ENTIRETY FROM THE ROOF OF INSTALLATION OF NEW CONSTRUCTION, OR WHERE EXISTING ITEMS WILL BE THE TENANT SPACE PARTICULARLY WHERE EXISTING ITEMS WILL INTERFERE WITH EXPOSED IN THE NEW CONSTRUCTION, UNLESS SPECIFICALLY SHOWN ELSEWHERE THE INSTALLATION OF NEW CONSTRUCTION, UNLESS SPECIFICALLY SHOWN IN THE CONTRACT DOCUMENTS TO REMAIN. REPAIR AND PATCH ALL SURFACES ELSEWHERE IN THE CONTRACT DOCUMENTS TO REMAIN. REPAIR AND PATCH ALL TO REMAIN WITH MATERIALS MATCHING EXISTING CONSTRUCTION. COORDINATE SURFACES TO REMAIN WITH MATERIALS MATCHING EXISTING CONSTRUCTION. WITH NEW CONSTRUCTION. COORDINATE WITH NEW CONSTRUCTION. 17. VERIFY ALL DIMENSIONS WITH FIELD CONDITIONS. 18. COORDINATE ALL DEMOLITION AND REMOVAL ITEMS WITH CONTRACT DRAWINGS. REMOVE ALL ITEMS AS NECESSARY FOR NEW WORK SHOWN WHETHER INDICATED AS ROMVAL OR NOT. D C , 1 ±35'-0" ±35'-O" ±38'-9" I I I I II I I --__....------------------------------------------------------- --- 1 I � ±167'-5 1 /2" 1 i 1 ---------------------------- 1-- — - — - — - — - — - — - I C❑ORDINATE FLOOR ' REMOVALTRENCHING W/ NEW FLOOR PLUMBING (S1-E MEP) 1 I 1 COLUMN LINES TO BE FIELD VERIFIED, 1 1 ----__--_---------------_.----_---__�—_-- _ I I V,I.F. REMOVE ALL EXIST, FLOOR FINISHES QZ PP-01ITPF7n P-nP NF'\./ 1 FINISHES I 1 REMOVE EXIST. VESTIBULE "CONTRACTOR'S VERIFICATION OF EXISTING CONDITIONS" (Refer to Section 02060) I, VERIFIED EXISTING CONDITIONS AND (WNIRACTO" xRFMRETOMO ALL ARCHITECT —REQUESTED OVERALL AND INTERMEDIATE DIMENSIONS ON THIS DRAWING, ON FOLLOWING PARTIAL OR COMPLETED DEMOLITION WORK (SURVEY DATE) AND SENT COPY OF THIS ANNOTATED DRAWING TO THE PETCO PROJECT MANAGER AND THE PROJECT ARCHITECT NO LATER THAN THE FIRST SUBMISSION OF THE APPLICATION FOR PAYMENT. LEGEND _--------__-- DASHED LINES INDICATES CONSTRUCTION TO BE REMOVED, VERIFY EXACT ITEMS IN FIELD, REM❑VALINCLUDES ALL ACCES❑RIES AND ALL ITEMS AS REQUIRED FOR NEW C❑NSTRUCTI❑N, EXIST. CONSTRUCTION TO REMAIN. B A Z I , .,I I II ' /45'-0 3/4" ±3" �t / w U z H z w T z C0 DEMOLITION PLAN_ REF.: N � � r � r co r o 0 p r O N C� O _ � � r o co — N SOURCE: 01 ,r 0 0 c m p r U 0 CU p s QD y LO Y U } rn N U + (D N 0 N Z N U m can " C cn L (D 0 0 N ON L a) U) Z � IL Architect: am License It: 001 J m J m QU ILL 06 Z U) c W L01- m ❑ ILLO� z W=o UnQ- � Z°LL �— I W w WZ Wow Q_U) Q zz0 2 z W �OWQ - I-- 0 (f) O Q• • a Z z o o8 U C7 W °° L W �p �n Z DISTRIBUTION: DATE: PERMI r 08/13/04 S/B°JL(M JOEW PETCO P.M. JOB N DRAWN: CHECKED: DEMOLITION PLAN Al .2 CSC, ui 0 _z 3 Q w w z N z Q w J I- w Q X O w z z a ty IL 0 a O a U) z 0 Z w Q � W g6 ly 4 Ow U(y- Q� Q Io V) Z z oLL �0 Q� Z O Ow z 0 F- Q w T X tL w� )O J z a w0 aQ Oq Q LL = v, 0Q • 0 G T E D C BT "L ±17'-4" ±41'-1 1/2" ±35'-0" ±35'-0" ±38'-9" -±5'-0 3/4' ±3" I VERIFY ALL DIMENSI❑NS INDICATED i 1 40::::{:::::::::::::::r 40 e !! V.I.F. V.I.F. 1 � : L { 1J N LN } r� co t`i r COLUMN LINES TO BE FIELD VERIFIED, - - - .............. < 42 0 ........................................ } REMOVED C❑NC,L_ SLAB IN TUB ROOM I i - i' EM "v �'• / o •rl Ifi IIIf _ r = r Z I O ........................... ,— N FIELD VERIFY (X'-X") YI I 0 r co N N • � W I I' ,f I zll ! Q 45 —� � 48 1 �0 o ti co . N I I I I — � o NVERIFY ............................� VERIFY` VERIFY V.I.F.�`,, H T 48 49 t �1 VERIFY , 4....- .............................. o ® �I O ---------- -------------------- ±167'-5 1 /2" >: VERIFY ALL DIMENSI❑NS INDICATED (TYP.) "CONTRACTOR'S VERIFICATION OF EXISTING CONDITIONS" (Refer to Section 01010) I, VERIFIED EXISTING CONDITIONS AND (CONTRACTOR'S SUPER�(TE?OF71T) ALL ARCHITECT -REQUESTED OVERALL AND INTERMEDIATE DIMENSIONS ON THIS DRAWING, ON (SURVEY DATE) AND SENT A COPY OF THIS ANNOTATED DRAWING TO THE PETCO PROJECT MANAGER AND THE PROJECT ARCHITECT NO LATER THAN THE END OF THE FIRST WEEK OF TENANT IMPROVEMENT CONSTRUCTION. BUILDING SHELL VERIFICATION PLAN 01 REF.: SOURCE: 1/8"=1'-0" c 0 c rn m CD m 0 0 0 L r CO LC) J } pL0j CO .SC U) N U N E C Z N Lo 0 c co E } O — a Nxx to a) c>i U) r Z LL Architect: 46mQ6 Cohen License It: 001'5903 _.I m J m W 06 Z < w Om O ®-, LL z w�O U0 �— U) I z0u- w w wZ) o (o0 zzo 0-0W< H 07 U) N •� z O�U oa WW �o �Z DISTRIBUTION: DATE: PERMIT 08/13104 J. SBLM JOGH PETCO P.M. JOB U ® 1® T5 DRAWN: CHECKED: WAWM TUM BUILDING SHELL VERIFICATION PLAN Al .3 .4� u� Qz a W W 2 F- z 0 W W 0 Y O W z O z 0 0 a 0 0 Q! a z 0 w z w 0 w vi �- W gU_ ryn OW U � O � Z Q Z Z zQ ow PO o� Z U 0 (9z z0 f, ry Q W W ul 2 lL LL W F' >0 �z =EL in 0 r1t!a 0n �a z 0z U Q • E a� P1 * 7/8" x 20 GA. Met F.C. framing 16" o.c. secure adj. wall substrate * Partition Framing Hgt. 9'-0" min., brace tSjKructure on concealed side(s) * 5/8" Gyp. Bd. one side (5/8" G d. if sched. on Fin. Sched.) * Gyp. Bd. Fin. to 8'-6" h side * Total Partition Thk. 1/ face of adj wall surface (non—firerated) P1 A Same as partition ,with exception of: *gyp. bd. fin. to rom underside of roof deck. *concealed blocking where noted P1 B Sam s partition Type P1, with addition of: * xp. Met. Security Mesh ( see 05500) to 8'-0" nom. hgt. * Total Partition Thk. 1-5/8" from face of adj. wall surface (non—firerated) P1 C * patch and repair existing wall finish P2 * 2-1 /2" x 20 GA. Met. Framing 16" o.c. adj. to wall substrate w/ 3/8" nominal clear space (gap) * Partition Framing Hgt. to 12" abv. highest adj. Clg. Hgt., brace to structure on concealed side(s) * 5/8" Gyp. Bd. one side (5/8" M.R. Gyp. Bd. or 1/2" Cement Board, where sched. on Fin. Sched.) * Gyp. Bd. Fin. to 6" min. hgt. above adj. clg. hgt. * Total Partition Thk. 3-1/2" from face of adj. wall surface (non—firerated) Some as partition Type P2, with exception of/addition of: P2A * Partition Framing Hgt. to 1" from underside of roof deck. * Gyp. Bd. Fin. to 1" from underside of roof deck. P2B Same as partition Type P2, with exception of: * 6 x 20 GA Met. Framing 16 O.C. PP2C Same as partition Type P2, with exception of/addition of- 2 Framing adj. to wall surface w/ 1/4" nom. clear space (gap) * Exp. Met Security Mesh to 8'-0" nom, hgt. P3 * 3-5/8" x 20 GA. Met. Framing 16" o.c. * Partition Framing Hgt. to 12" abv. highest adj. CIg. Hgt., brace to structure on concealed side(s) * 5/8" Gyp. Bd. both sides (X" Cement Board where sched. on Fin. Sched.) * Gyp. Bd. Fin. to 6" min. hgt. above ad} Clg. Hgt. both sides of partition * L—bead Gyp. Bd. edges adj. to aluminum storefront and dissimilar materials * Total Partition Thk. 4-7/8" (non—firerated) Some as Partition Type P3, w/ exception of: P3A * 6"x 20 GA Met. Framing 16" O.C. P3B Same as Partition Type P3, w/ addition of: * 3-1/2" (R-11) Sound Atten. Batt Insul. to 12" abv. highest adj. CIg. Hgt. / DI 17 A] \ P3C Same as Partition Type P3, w/ exception of/addition of: * 6 x 20 GA. Met. Framing 16 o.c. * 3-1/2" (R-11) Sound Atten. Batt Insul. to 12" obv. highest adj. CIg. Hgt. P4 * 3-5/8" x 20 GA Met. Framing 16" o.c. * Partition Framing Hgt. 13'-0" min., brace to structure on concealed side(s) * 5/8" Gyp. Bd. both sides (5/8" M.R. Gyp. Bd. if sched. on Fin. Sched.) * Gyp. Bd. Fin. to 6" min. obv. Clg. Hgt. (see Fin. Sched.) both sides of partition * Total Partition Thk. 4-7/8" (non—firerated) P5 * 3-5/8" x 20 GA. Met. Framing 16" o.c. * Partition Framing Hgt. to underside of roof deck abv. w/ Deflection Runner * 5/8" Gyp. Bd. both sides (5/8" M.R. Gyp. Bd. if sched. on Fin. Sched.) * Gyp. Bd. Fin. to Full Hgt, both sides of partition * Total Partition Thk. 4-7/8" (non—firerated) P6 * 3-5/8" x 20 GA. Met. Framing 16" o.c. * Partition Framing Hgt. to underside of roof deck abv. w/ Deflection Runner * 5/8" Gyp. Bd. both sides (5/8" M.R. Gyp. Bd. if sched. on Fin. Sched.) * Gyp. Bd. Full Hgt. one side, to 6" min. abv. CIg. Hgt. (see Fin. Sched.) on other side * L—bead Gyp. Bd. edges adj. to aluminum storefront and dissimilar materials * Total Partition Thk. 4-7/8" (non—firerated) Same as Partition Type P6, w/ addition of: F� * 3-1/2" (R-11) Sound Atten. Batt Insul. to 12" abv, highest adj. CIg. Hgt. P6B Same as Partition Type P6, w/ addition of- * 6"x 20 GA Met. Framing 16" O.C. * 3-1/2" (R-11) Sound Atten. Batt Insul. to 12" abv. highest adj. CIg. Hgt. P7 * 3-5/8" x 20 GA. Met, Framing 16" o.c. * Partition Framing Hgt. to 8'-0" * 5/8" Gyp. Bd. both sides (V Cement Board where sched. on Fin. Sched.) * Gyp. Bd. Fin. to 8'-0" * L—bead Gyp. Bd. edges adj. to aluminum storefront and dissimilar materials * Total Partition Thk. 4-7/8" (non—firerated Pg 1 HR. Fire Rated Assembly (U.L. Desi o. U419) * 3-5/8" (or 6") x 20 G �t. ming 16" o.c. * Partition Framing erside of roof deck abv. w/ Fire Assembly —testa f fl Runner (see 09260) * 5/8" Type d. both sides (5/8" Type—X/M.R. Gyp. Bd. if sched. on Fin. Schad.) * Gyp. in. to Full Hgt. on both sides of partition. * afing/Fire Sealant at top and Fire Sealant at base of partition otal 1 HR. Fire Rated Thk. 4-7/8" (or 7-1/4") P8A Same as AdJ Partition Type P7 w/ on of: * 3-1/2" (R-11) Soundn. . Insul. to underside of roof deck abv. P9 2 HR. Fire Rat&KA y (U.L Design No. U419) * 3-5/8" 20 GA. Met. Framing 1 " O.C. * Partition ming Hgt. to underside oof deck abv. w/ Fire Asse —tested Deflectio nn see 09260) * ayers 5/8" Typ d. both sides (5/8" Type—X/M.R. Gyp. Bd. if sched. on Fin. c * Gyp. Bd. Hgt. on both sides of partition. * Firesafing ealant at top and Fire Sealant at base of partition * Total Fire Rated Thk. 6-1/8" (or 8-1/2") P9 * me as Adj. Partition Type P8 w/ addition of: 3-1/2" (R-11) Sound Atten. Batt. Insul. to underside of roof deck abv. PARTITION TYPES REF.: FLOOR PLAN REF.: SOURCE: SOURCE: 16 N.T.S. 01 1/8" = 1141 C 0 ch c rn c� 0 0 0 0 T (S% } _X LO U 0) Co N U -c- 3: CAI NI E CID Z LO O Ca ) >_ 0 O O N -0 CN x`O (D�, (A ,- Z FCfD - Architect: Jam License #: 001 J m J _j m QC �Z LL� 06 U) � � QW 0 m�a 0 i ZwDo �E, < P0_1 cn z 0 LL W� C�v-o ®_ {) 0 z z 0 wiz o�� V Cr 0 QLL O� U zW� w ao rn� DISTRIBUiION: WE: PERMIT U8/13/(Y1 SBLM JOB# PETCO P.M. JOB # o o�5 DRAWN: CHECKED: DRAWING FLOOR PLAN AND PARTITION NOTES A2.1 w vi w U �n Ow U � U 0 [n zQ aX Zz z Q Ow �= 0 ZU 0W z0 w w� LLX Fy wr- >0 z Q� za U� U) aQ o� oz U Q • R r� N cV r N co co C n G ± 17'-4 t41'-1 1/2" T Y-2" T t35'-0" I o - ®' G15S G158 G15S G1SS G15S G15S G1 G15S G15B G15S G15S G15S G15S G15S G15S G 5S G15S G15S G 5S G� G15S G15S G15S G15S I - I Y�Z Do4 Iftu I sG.2 SM.1 WOMEN'S 4 " - I. 4, 4' 4' 4, 4, L L 4' 4, LAWAu 4' 4' COR. II G3 G3 GPI0 119 II 4'-8 c 33 I �c 0 33 0 is MEN S 109 � (— � °� � ��� G3 G3 1,g 4 GS G3 met 11a1 5' G12 4s 1107 ROOM G8S GOScq 31P3� RETAIL Ges GOs I I 102 RORK OOM I 118 CLOSET IBREAK RM CLOSET 1 00 PRE SALES T !L38'-9" CLOSET t3" G15S G15S GR44 GR.441 CGm ClRO 105 ° 'k TUB ROOM r x 106 i ° 4'-3 w jOMING SAL®, — A -- i GROOMING � �� 1.c. RECEPTION 104 — G8s G88 GAS G88 G88 s G4 G4 G4 G4 G4 I 4' 4' 911 . m G2 G2 G2 4 till G4 G4 G4G4 G4 G2 G2 G2 " 4, b - J W jr G4 G4 G4 G4 G4 G1 G1FL GI 4' GI- -. 4' G11 Gl Gl G4 G4 G4 G4 G4 5 c�h G4 I G4 G4 G4 G4 G4 G4 G4 G12 _G4 3 G3 G3 �'IV G. "It � r" I 4' Gil 4' G4 14' 4 4, 499c c \� F It �� G15S G15S G15S G15S LG15S I G15S I G153 5S I G15S I G15S I G15S I G15S I G15S I G15S I G15S I G15S JIG1591 G15S I G15S I G15S I G15S G15S G158 G15S G15 t167'-5 1 /2" 0 GROOMING LOBBY/WAITING 1n— ELECTRICAL PANEL WITH 36" x 36" CLEAR FLOOR AREA—TYP. THIS STORE FIXTURE PLAN SHALL NOT BE USED FOR LAYOUT PURPOSES. STORE FIXTURE PLAN NOTES, GENERAL: 1. STORE FIXTURES, FURNISHINGS AND EQUIPMENT SHALL BE INSTALLED AND LOCATED IN ACCORDANCE WITH A STORE FIXTURE LAYOUT PLAN PROVIDED TO THE CONTRACTOR BY A PETCO REPRESENTATIVE AT THE TIME OF STORE FIXTURES, FURNISHINGS AND EQUIPMENT DELIVERIES TO THE JOBSITE. FINAL LOCATIONS MAY VARY FROM AS SHOWN ON THIS FLOOR PLAN. 2.REFER TO PROJECT MANUAL SECTION 10300 FOR PETCO STORE FIXTURE/ FURNISHINGS/ EQUIPMENT KEYCODES. 3. FIRE EXTINGUISHERS (10300) SHALL BE PROVIDED AS SPECD. AND IN ACCORDANCE WITH APPLICABLE CODES. FIRE EXTINGUISHERS SHOWN (TOTAL 8) BASED ON 1 PER 2,000 S.F. T 4. SYMBOL KEY: ®FE 3A-40B: C FIRE EXTINGUISHER W/ WALL BRACKET & SIGN (10300) t5'-0 3/4" 11 1 II I LLI I 0 L I� i Z F10-11 VESTIBUL / Ell ism it'llEll / I o W14S 1/14S PI IBM I F I I 1 / s- G15S I G15S I 05S I G158 I GI — OFFICE CV r N r CV o CD O N N 0 0 r 0 v co O co N _ - 0 STORE FIXTURE PLAN REF.: SOURCE: 01 118" = 1'-0" c O U C ca CD a� 0 0 4= 0 0 t r co LO o 0Lc)) CO yC CA } Cn CV U _ N c'\I E N Z N L O m 0 E m } -C N U) CL w N LO w c cn ,-• Z F— u- aRw® CfD It %"1 c, Architect: JamjdsQohen License #: 001 903 c0 J J m < C) o 2z ILL 06 Uj ry � <W 0 m�< ,® 0 0—� zW�o can z0LL �• I W W WD o WOO a.Cn 0 ZZO w Z �0U)U) a VNN m a a O :3 QLL 0 IL W DISTRIBUTION: DATE: PERMI i 00113104 SBLM JOB# PETCO P.M. JOB # togJ75 DRAWN: CHECKED: ow► ING nn.E STORE FIXTURE PLAN A2.2 uj U _z ° w W w z z ° w J I- w ° x a 0 3 w L2L 'r Z 0 a a 0 a 0 a z 0 U) z w 0 w vi Qw U wa 0w U a ° v0i (1)} zz oQ F- V_ 0 Q� Z U 0� z a HQ 57< w w� �u- w H >o z za �0 as OJ z 0z 40 — 48 49 — 50 — WOMEN'S 108 EL 8'-0" CEILING COR. I 119 EL 8'-0" CEILING MEN'S 109 EL 8'-0" CEILING ISO, ROOM 117 — EL 8'-0" CEILING WORK ROOM I 118 rL EL 8'-0" CEILING JANITOR'S CLOSET ( 120 COR. L11 I BREAK RM 112 EL 8'-0" CEILING CLOSET110 PRE SALES 116 0 T T TF ■ ■ /ACT-1 EL 7'-11" EL 7'-11" 1i u 0 R1=TAIL O i02 O REFLECTED CEILING PLAN NOTES, GENERAL: 3. SYMBOL KEY: 1. VERIFY MEASUREMENTS WITH CORRESPONDING CONSTRUCTED OR LIGHT FIXTURE IN SUSPENDED ACOUSTIC EXISTING CONDITIONS PRIOR TO PROCEEDING WITH THE WORK, AND ® TILE CEILING / REF. ELEC. NOTIFY THE ARCHITECT IMMEDIATELY OF SIGNIFICANT DISCREPANCIES SURFACE MOUNTED / UNIISTRUT USING THE "CONTRACTOR REQUEST FOR INFORMATION" FORM (01200) MOUNTED LT. FIXTURE / REF. ELEC. AND SUPPLEMENTARY CONTRACTOR DETAILS AS REQUIRED. © DIFFUSER / 2. REFER TO SHEET AO.2 AND PROJECT MANUAL SECTION 10300 FOR REF. MECH. DESCRIPTION OF THE DIVISION OF RESPONSIBILITIES BETWEEN PETCO CONCENTRIC DIFFUSER / VENDORS AND CONTRACTORS. L.. REF. MECH. ACT— CEILING TILE TYPE/REF. A3.1, 09510 B T A Z ............................... _ ........6....................... ........ ACT CEILING EL 7'-11" SOFFIT EL 8'-0" • � rc 'TTf4. 3 1/2" SOUND ATTENUATION BATT INSUL. ABV./ON SUSP. ACT (OFFICE ONLY). MAINTAIN CLEARANCE FROM LT. FIXTURES. NOTE: ALL EXPOSED CONSTRUCTION AREAS TO BE PAINTED PER SCHEDULE. PREPARE ALL EXIST. SURFACES AS REQUIRED I CAGE ROOM 105 EL. 88'-0" Y CEILING I TUB ROOM 106 EL 10'-0" CEILING GROOMING SALON 107 EL 8'-0" ACT-1 CEILING GROOMING EG PTFO ELT 12'-0" ACT-1 42 CEILING — — 4 GYP. BD. EL. 12'-0" CEILING CONSTRUCTION: 5 W.R. GYP. BD. ON 7/8" x 20 GA F.C. 12" O.C., ON I, PERPENDICULAR 2 1/2" x 20 GA. MET. FRAMING — R+� J()ISTS 24" O.C., SUSP_ FROM BAR JOISTS ABO I �I GROOM— LOBBY/WAITING I I 103 I I EL 12'-0" F1011 VESTIBULE CEILING ACT-1 4 � I I Lj --L1131 OFFICE EL 8'-0" c 0 0 rn so r O m O O O O s r- (D LO --� ( 5 aq '0 SG (n CO N U +� ID N EO Z N Lr) op U) cc� i O O O N QN t LC) (1) a� cn z F- - CfD Architect: JameF/Cphen License #: 0015W3 —j J m J J b m D; Z= Zw 0a w Q O m�o O ---� LL Z w � O U� Z0LL (� WW W:D 0 WpcY I]m Cn F- z z o WS�Z OU)U) 40 V� z z 0 OCT =w w �o N Z DISTRIBUTION: DATE: PERMIT uulu/04 SBLM( JJQB# a� PETCO P.M. JOB # DRAWN: CHECKED: REFLECTED CEILING PLAN A2.3 U` z_ Q a w rn W 2 F_ z w J I¢- W O x a 0 W 2 F- (7 z 0 J O a a 0 a 0 a rn z O z w 2 0 w rn I-- W U a4 O W �a ❑ vi zz OQ 1 u- -0 U F, Z U Ow U F- U= z� h Q XW W LL U- T F_ W z a� =a �o �a QW J U Q U) OQ • 21 40 - 48 e ROOF STRUCTURE. C O N O c rn q T V o 0 o 0 O o a) U Lo N U (D N O ZN� c� Ca ) c o E b D O O N Q } -r- ,- U? (D N Architect: JategX,ohen License #: 0015903 0 J m J �I bLL m 0_ .7� 06 L U)Do 0 ®—j LL z In 1- WDO U ®— < t-W O �ww Z 0 W� owOO 0 a-U) h ZZ W a. 0 Lu �- cn cn [V N S "L O •� Etc) OCT UU ww �o Mz 96 C11 - m� DISTRIBUTION: DATE: PERMI r 08/13/04 SBLM JOBS PETCO P.M. JOB 0 O�d7�� DRAWN: CFIECKED: DRAWING TITLE: ROOF PLAN A2.4 w Q F- w Y a 0 w T I- (.9 z 0 fy I 0 F- a 0 a IL U) z 0 Fn z w C H w w Z � n- o w 0 N U () ❑ U) ¢° W} z zQ O LL PO ❑ [- ZU 0w U I- z 0 HQ �w T x LL w F- >0 z Q J =a V)o 6a 0 J �< I f- N o°zQ r�� 11 l�D ;� _t I ,. SF05 CLEAR ANODIZED WALL BUMPER (10300) ON RETAIL SIDE - ONE WAY GLASS OR REFLECTIVE PRIVACY FILM (08800) ON RETAIL SIDE (OFFICE ONLY) r 1171, T.G. 1. I-, , I <<, 4 :� \ < <. -) I I, SF06 CLEAR ANODIZED T. � _ '� T.G. .\ D - - / �,) / . I T.G. / 101� 1 1.1 '2� '��_ v 1 /2" SF02 CLEAR ANODIZED T.G. LOCATE KEYSWITCH ON RETAIL SIDE 8'-6jUllN2 ANSOM B AUTOMATI T.G. DOOR SIGN (10300) 1-3/4"TYP. INTERIOR STOREFRONT SECTION T.G. I I omek. :... 4 AJI' 1-3/4"IYP. INTERIOR STOREFRONT SECTION c: ol :,Dz -r;s�.� 51M. T.G. T. G. ( 9. SF04 CLEAR ANODIZED T.G. I T.G. T.G. ONE WAY GLASS OR REFLECTIVE PRIVACY FILM (08800) ON RETAIL SIDE CSF0] CLEAR ANODIZED ONE WAY GLASS LOCATE KEYSWITCH ON RETAIL SIDE (INTERIOR DOOR UNIT) AND ON VESTIBULE SIDE (EXTERIOR DOOR UNIT) & 1 AU-2 OD 0 CLEAR ANODIZED (INTERIOR ( Q INTERIOR U 72 BREAKOUT NIT W , CLEA ODIZED RAN UNIT) W/ 44 1 /4" BREAKOUT EXTERIOR UNIT W/ 72" BREAKOUT, FINISH/ COLOR TO SEE A2.1, A7.1 FOR 0-SX MATCH EXTERIOR STOREFRONT HANDING OF AU-1 UNIT (CRITICAL) H.M. WELDED FRAME W/ NO STOPS CLEAR PLASTIC IF DOOR AL. HDWE. L R A � VISION LITES VARIES 4" HM HEAD - - - \ _ -/ WHERE \ / \ r 711 �����ITY \ / \ I / \ 12"H.x 20"W. DOOR \\ / / \ \ I / I �• \\ MET. LOUVER VIEWER // MERE 0 \ \ \ / / I SCHED. p / \\ \ / I LIB / // I \ I \\ / /10" EXIT ALARM, // \ / FIRE/EXIT DEVICE / \ L_ - -\1, / i u I i RD WHERE SCHED. F DA AL-1 FL • I T.G.= 1/4" TEMPERED GLASS DOOR & STOREFRONT TYPES REF.: SOURCE: ROOMS WALL FINISHES : A2.1 ROOM . WALL CEILING MATERIAL/ : TEXTURED/ WALL MATERIAL/PAINT COLOR: SEE SYMBOL ON A2.1 FOR ORIENTATION 1 MARK NAME FLOOR MATERIAL (REF) ! BASE I PAINT COLOR CLG. HT. UNTEXTURED 1 2 3 4 : REMARKS _ .... _........................................................ 101 VESTIBULE _................................. .... ...........................:..................................................3...................................................................................................................................................................................................... = FLOOR MAT (10300) - SUSP ACT-1 12'-0" I - 1 - ........................................................ _. ...... - __._..._.._....._.... - _..._....................... - .._....... _....................................................................................................................................................... i ----------........... 102 ..._.......__........................................................................t. RETAIL ....._....._......................................_......._..._.............�.................................................`•....................................I...... : > i E VCT (09650) : VB Z I 1 ................................................................................................................................................................................................ OPEN STRUCTURE/ PTD WHITE - i i SEE NOTE 8 f GYP -GRAY I GYP -GRAY GYP -GRAY GYP -GRAY t l REF. A2.1 WALL FINISH KEY _ 1 03 ___ GROOMING LOBBY / WAITING --..._-------------------- VCT 09650 .............................-........-.._.....-.......-...._.._._.__... VB j _ _ PTD WHITE _ - ;. _ __ i S EE ----...- 0 N TE - .....-..._.............. 8 - GYP GRAY _.._... - G YP GRAY G GYP -GRAY RAY - -_ _ - G (P GRAY :REF. - A2.1 WALL _._ ___ ---_ FINISH KEY i 104 GROOMING RECEPTION --�__ I VCT (09650) 1 _ _._....,..-_......_. VB ___.____._....!. SUSP ACT-1 12'-0" _ _ SEE NOTE 8 GYP -GRAY : GYP -GRAY GYP -GRAY GYP -GRAY I REF. A2.1 WALL FINISH KEY 105 CAGE ROOM ........... . ........................................................................................................................................................................................................................................................................................................ EPDXY (09670) : 6" EPDXY I i SUSP ACT-2 ... 10'-0" .. . .........................................................................................................................................................................................................................................................._................................................................................... 1 - FRP/GYP-GRAY I FRP/GYP-GRAY FRP/GYP-GRAY FRP/GYP-GRAY : FRP , FULL HOT. - ._.._...-___ 106 TUB ROOM I EPDXY (09670) : ------ -.....---i...__.._...._..__....___. 6" EPDXY ___ : M.R. GYP -WHITE ______ __ _ _ _ _ 8'-O" ._....____.._...._..._i----._.....-.-_-._..._....._.....-...._. ! SEE NOTE 10 C.T./ CEM. BD. : C.T./ CEM. BD. C.T./ CEM. BD. . C.T./ CEM. BD. I 1 07 GROOMING R00 M VCT 09650 ( ) : CB E � ! SUSP ACT - 1 n - 8 0 i S SEE NOTE 8 ........-_...__..._-....._...._.._-_._..___.t___-_...._-..-_...--.___ M.R. GYP. C.T. 1 GRAY A V. I M.R. GYP. C.T. GRAY A V. M.R. GYP./C.T. GRAY ABV. M.R. GYP./C.T. GRAY ABV. I C.T. _ - 3 5 __ _- - n- 1 /4 HOT., PAINTED GRAY ABV. ..... .................. 108 ...................._...._.... _.... -......................... _......... _.... _.._............_...........................................................................;.................................................:..................................................................................- WOMENS RESTROOM : ; VSF (09660) I 6" VSB SUSP ACT-2 ............................... 8'-0" ............................................................................................................................................................................................_.._... SEE NOTE 8 FRP/WM.I YP- FRP/M.R.GYP- ..--••-....---•-----•..._...................._...... FRP/M.R.GYP- .........._.............................................1................................... FRP/M.R.GYP- :FRP 4'-0" HOT.; "WOMEN" SIGN 10300 ( ) _-_ _ __......._._...__.._......_.._ _.__.__......_ .. --r. __ _ WHITE WHITE WHITE 109 MENS RESTROOM i � VSF (09660) I n 6 VSB � SUSP ACT-2 r n 8 -0 ! 1 SEE ._.-._.._...._.....__. NOTE 8 _. _._... _ ....._.....__.._.__..._;_._______...._._.._____.__ _ - FRP M.R.GYP I / WHITE - FRP M.R.GYP /yVl.-II-I-E _ F GYP RP M.R. WHITE _ FRP M.R.GYP WHITE j FRP r n 4 -0 HOT.; - "MEN" MEN SIGN (10300) ......... .............. _ 110 ... ............ -............................... ...... ...... _.........._......._...................__............_....._............................................. CLOSET >...................................................................................................................................................................................................................... i i CONC. SEALER (09910)1 - : : OPEN STRUCTURE - ! - ........................................................................................................................................_--......._...._..._.._.._..._.... GYP-UNPTD. i GYP-UNPTD. __._...._.___......._.............._......................._. GYP-UNPTD. GYP-UNPTD. ---- -__ - ___ _ F......._......_....__._. ,__ ._ _ _ ._._.._ ------.----.:--------------.-------- .................__........._ .___.___-_.______ _.___ __.._..._..._..._.._.__ : ' 111 CORRIDOR i VCT 09650 VB U S SP ACT-1 r n - 8 0 S EE NOTE 8 I - GYP I WH TE - GYP WHITE - GYP WHITE - GYP WHITE i ,FRP r n _ 4 0 HOT. AT EWC 112 BREAK ROOM : VCT (09650) VB SUSP ACT-1 8'-0" I SEE NOTE 8 i GYP -WHITE GYP -WHITE ..... GYP -WHITE ..................................................................o GYP -WHITE ........................... i ............................................. ............................................................................................ 113 OFFICE VCT (09650) VB 1 SUSP ACT-1 r n 8 -0 I SEE NOTE 8 GYP -WHITE : GYP -WHITE GYP -WHITE GYP -WHITE ' ........................................................................................................................_. .................................................................................................................................i...................................................................................................................:.................................................................... . i ..................................................................4........................................................_. ............ .................................................................................................... .......... 114 CLOSET _ _ : CONC. SEALER (09910)1 _ --"'-_"__.t..._._- - ................--_--____f._....................._.._......________.. :OPEN STRUCTURE - ._..... ....---.-----------. - GYP-UNPTD. 1 GYP-UNPTD. GYP-UNPTD. GYP-UNPTD. I i 115 AQUARIUM AREA : EPDXY (09670 : I OPEN STRUCTURE / - : - ------.------------.-...._.._..----------------�'--------"---------------- - 1 - - - SEE NOTE 2, 3, -- 6, 7, 8, 9 ........_.._........................... 116 PRE -SALES .....................................................................................� , CONC. SEALER (09910) : - i .. ....... .................... OPEN STRUCTURE/ WHITE ..........................o-..............................................................................................................................................................................................____. - : - i PTD. WHITE PTD. WHITE _......._...._...._ ................ _-_...._....................._.................................................1................. PTD. WHITE PTD. WHITE : PTD. .............................................................................. PLYWD. TO ..................................................................... 4'-0" HGT. ON GYP. BD. : __.i..__­._.._­ ........_�....._._ __.__ ........__.._PTD. _.__. _ _ _ _ _ ___.__ 117 ....._-__ . .......... ISOLATION ROOM .................................. ........................................... ........... I , CONC. SEALER 09910 : ( ) !.................__.................................................._...............,.................................................:.................................................................................................................:.......................................................................................................................................................................................... 6 VSB i SUSP ACT-2 8 -0 I : SEE NOTE 8 -1 M.R. GYP./FRP M.R. GYP./FRP M.R. GYP./FRP M.R. GYP./FRP :FRP FULL HOT. 118 WORK ROOM : CONC. SEALER (09910) : 6" VSB I SUSP ACT-2 8'-0" 1 SEE NOTE 8 M.R. GYP./FRP I M.R. GYP./FRP M.R. GYP./FRP M.R. GYP./FRP :...................................................................... I FRP FULL HOT. ------ 1 9 1 CORRIDOR ;-------............i........-........_..__.-___........_..........._......_...___._.......____......_.........._._.. , VCT 09650 ( ) 1.........................................................................................:........................................................................................................ VB I SUS PACT-1 ._................_... r n 8 -0 S EE NOTE 8 __..._- ._.._._._,.._.__........._..._......_...__ - I GYP WHITE GYP-WHI - GYP WHITE - GYP WHITE ;FRP r n _ 4 0 _.___.______..___........_. HOT. AT EWC - ............. ......._.........._................................................................. . ; .........................................................i......................................................................................................................................................................................... i _.. _ .._........................__._......._..__......._................._................................................i....................._............................................................................................................................................. 120 JANITOR CLOSET CONC. SEALER (09910) : VB M.R. GYP -WHITE 8'-0" : - M.R. GYP./FRP 1 M.R. GYP./FRP M.R. GYP./FRP M.R. GYP./FRP I FRP FULL HOT. GENERAL FINISH NOTES: 1. EXPOSED STRUCTURAL COLUMNS PAINTED GRAY/ PROVIDE STAINLESS STEEL COLUMN COVERING (10300) TO 42" HOT./ REF. DET. 12/A8.2. 2. AQUARIUM AREA: POWER POLE SHALL BE 'FLAT BLACK'. 3. EXPOSED FIRE SUPPRESSION PIPING, PLUMBING, MECHANICAL AND ELECTRICAL EQUIPMENT SHALL BE PAINTED SUBJECT TO LIMITATIONS (09900). 4. PROVIDE WALL CORNER GUARDS (10300) AT ALL INTERIOR PARTITION OUTSIDE CORNERS, EXCEPT WHERE NOTED OTHERWISE/ REF A7.1. 5. PROVIDE WALL BUMPERS (10300) AT INTERIOR PARTITIONS/ REF. A7.1. 6. EPDXY FLOCK, FINISH (OVERLAYMENT) & BASE/ REF. DET. 08/A8.2. 7. SEE FLOOR PLAN (A2.2) FOR EPDXY FLOOR LAYOUT DIMENSIONS. 8. CONTRACTOR'S OPTION TO PROVIDE 'LIGHT ORANGE PEEL' TEXTURE, OR UNTEXTURED (SMOOTH FINISH). ALL WALLS AND EXPOSED WALL RETURNS (FOR EXAMPLE, AT STOREFRONT) SHALL BE EITHER 'ALL TEXTURED' OR 'ALL UNTEXTURED'. g, PAINT COLOR GRAY. PROVIDE PAINT COLORS PER SECTION 09900. FINISH SC i-'! E D U LE 11 10. INSTALL 6 MIL (MIN.) POLY VAPOR BARRIER BEHIND CEMENT BOARD TILE BACKER AND SECURE TO METAL FRAMING. REF.: A2.1 SOURCE: 1/2"=1'-0" DOOR FRAME A2.1 SWING ; i FINISH I HDWE FIRS I 1 I i MARK FROM TO / TYPE MATERIAL I WIDTH HEIGHT THK. FROM/TO 1 MATERIAL : HEAD FINISH SET LABEL REF REMARKS ...................................................._.................................._._...................... I................................................................................................................................ ' i r n r n................................................................................................................................................i............................................................... ................__----"__........___._.__.............._............................_....._......_........1AUTO .............................. ............. _.......... ....................................................................................................................................... 1 101/EXTERIOR AU-2 ALUMINUM/GLASS LITES : 1UNIT UNIT I STD. MFR. PREFIN. I AL UNIT I STD. MFR. PREFIN. 1 - 08410 DR. UNIT W BREAKOUT w/ TRANSOM __. ! n r n E 14'- 0 7 -6 2 102/101 AU-2 ALUMINUM/GLASS LITES : UNIT UNIT I STD. MFR, PREFIN. AL UNIT : STD. MFR. PREFIN. 1 I - 08410 :AUTO DR. UNIT W/ BREAKOUT w/ TRANSOM --- ... -..........................._.................................................................................................._.................................................................................................................................................................................................................................................................................................................. i ; ................................................................................................................................................................ 3 103/101 AU-1 ALUMINUM GLASS LITES 8°-6" 7'-6" i STD. MFR. PREFIN. AL UNIT STD. MFR. PREFIN. 2 I - 08410 :AUTO DR. UNIT W/ BREAKOUT w/ TRANSOM / : UNIT UNIT I i f i r n r n , I f _ n 4 101 104 -AL 1 ALUMINUM/GLASS GLASS LITELIT 3 / M/ E 0 7 -0 ; STD. MFR. PREFIN. : ALUMINUM / 1 3 4 MFR . PREFIN. 4 08410 IOFFS ET PIVOT HINGES i HIN E , ....................................................................................................... 5 104/103 AL-1 ALUMINUM/GLASS LITE 3'-0" 7'-0" : STD. MFR. PREFIN. I ALUMINUM ! 1-3/4" MFR. PREFIN. 4 - 08410 }OFFSET PIVOT HINGES ! 1 r n r n i n� n 6 118/117 FL HOLLOW METAL 3 -0 7 -0 1-3/4 PTD. GRAY HOLLOW METAL : 2 PTD. GRAY 9 - 08100 FIXED MET. LOUVER _.._....__.............................................................................................:............................................................o.................................................................................................................................................................................;..............................................................................._._.__.._.._.._..............._.._..__ .......... __.......................... _._............._............ _ _...._................................_.............................. ... -............. ..... ................... -................ __.... ............................................ .................................... _...................... : : i i r n , n I n I - i 7 104 103 - S - _ / .AL 1 ALUMINUM/GLASS S LITE 3 0 7 -0 I STD. MFR. PREFIN. ALUMINUM 11 3/4 MFR. PREFIN. 4 i 08410 'OFFSET PIVOT HINGES __ ............_.............._....................................................................................................................:.................................................................... : ............................................................................................................................................................................................._._._.._-____- ___._..._..._ _...__.._._._.._.......__._._..._.._...__.I 8 119/109 F HOLLOW METAL : 3 -0 7 -0 :1-3/4 PTD. GRAY 1 - r n r n: n I I „ HOLLOW METAL : 2 PTD. GRAY 9 08100 __ _--- -_- _ _ -__ _.. __---- i--- ----------- - ......_...- -- _----.--.-.....-.--•--...----..._..__ ..._..._...................._.....-_•--•--..........-......-!.----__._-.__ - ----- __ .._- _.. __ _ - __ _ - 9 119/108 AL-1 DOUBLE ACTING ALUM. 3'-0" 7'-0" 1-3/4" MFR. PREFIN. I ALUMINUM 1 1-3/4" MFR. PREFIN. 7 I - 08410 CENTER PIVOT HINGES W/ PUSH BAR BOTH SIDES .....................................................:............................................................. 4.......................................................................................................•............................... .. , _.._.... _..................._._................................... f..............................................._._...._......._ ............_._.---.................. ..................................................................................................................................................................................................................... 10 114/105 FL HOLLOW METAL/LOUVER 3'-0" 7'-0" 11-3/4" -PTD. GRAY I_ HOLLOW METAL 2" PTD. GRAY 11 08100 FIXED MET. LOUVER i r n r n I n "- i ........ ....._ - __...._... n ._ _ 11 111/112 F HOLLOW METAL 1 3 -0 7 -0 11-3/4 PTD. GRAY HOLLOW METAL 2 PTD. GRAY 9 - 08100 I ......... _........__.................................................................................................................................................................................................................. i y............................................................:........................................................................................................:.......................................................................... i. 12 104/106 AL-1 ALUMINUM/GLASS LITE 13'-0" 7'-0" I STD. MFR. PREFIN. --ALUMINUM 11-3/4" MFR. PREFIN. 4 I - 08410 OFFSET PIVOT HINGES 13 102 113 F HOLLOW METAL 3'-0" 7'-0" I1-3 4" PTD. GRAY I __ - -- / / i HOLLOW METAL 1 2" PTD. GRAY 9 - 08100 - _...._.............................................................................................................................._..............................------------------............................................................................................................I.............................................................................................................................. . I I.........................................................................................................__..................--F_._............................ _........................... .............. ............._.._.......................................................................................................................................................... *14 102/EXT EXISTING EXISTING TO REMAIN : 1 PTD. GRAY I i PTD. GRAY *13 1 REFIN/REPAINT COLOR TO MATCH NEW SCHEME _.-..__._.-....-__-_,.__.....___� _ __._.._._r-____._...__ __._._..__...-._._.-___-_.____i___..__.___.._..__._._...__ ; _ _.._._..__ _ . 15 102/EXT FL HOLLOW METAL 1 3'-O" 7'-0" 11-3/4" PTD. GRAY - HOLLOW METAL : 2" PTD. GRAY 9 I 08100 i FIXED MET. LOUVER .._ ...... _..... ...... ............... _... _... ...... .......................... ..... -........... ..... -........ _......... -......... ..-.--............... .... ............. _............................................................................................................... €........................... I 1................................................................................................................................................................................................................................_._._._........._.__.....__...._.._.-__............___............................................r......................... I_..._................................................................................................ ; r n r n I n......................................................... 16 111 120 DA ELIASON DOOR {{ / ;(2)3 -0 8 -0 : 1 MFR. PREFIN. I HOLLOW METAL 2" PTD. GRAY 12 1 - 08300 IHM WELDED FRAME w/ NO STOPS _ ----�_.._._.._..........__.____ _ , _ .___ . __.......__. _ _...._.......--_.. _. _ _ ____- .. _ *17 116 EXT RD ROLLING DOOR - - _ _ _ _ - -----•_._ _. _._ __._.._.._._____ _ __.. _. _._____._ . / i - ` - REFINISH AS NECESSARY LIKE NEW Z....................................................................................................................................................................... 18 I i.__. _. i ..-- _ I ; __ *19 116/EXT - EXISTING EXISTING TO REMAIN PTD. GRAY - -�--�-YVwWW__ ____ PTD. GRAY *14 I REFIN/REPAINT COLOR TO MATCH NEW SCHEME ........................................................._........................................................................................................i.........................................................................:!...................................................................... ` .........................................................................................................................................................................................................................................:. ­­.­_.I .. ...................................................................................................................................... 20 114/115 F HOLLOW METAL : 3'-0" 7'-0" I1-3/4" PTD. GRAY I HOLLOW METAL : 2" PTD. GRAY 10 I - 08100 : ____..__......_____ _ _______ __ _ ___. .i___ __ _ _____. __ _-________i._...__.._._.-_-------_._._....______..t...__....._...._._ _ ___.__.___ __ = i _ r 21 110/116 FL HOLLOW METAL/LOUVER : 3'-0" 7'-0" 1-3/4" PTD. GRAY I HOLLOW METAL ' 2" PTD. GRAY 11 1 - 08100 I FIXED MET. LOUVER - Y�-� GENERAL DOOR NOTES 1. * EXTERIOR H.M. DOOR & FRAME PAINT COLOR TO MATCH ADJACENT BUILDING COLOR. 04 2. REFER TO FLOOR PLAN / LARGE SCALE PLANS FOR ALL DOOR "LEFT/RIGHT" HANDING. 1/4"=1'-0" 3. INTERIOR DOOR FRAMES PAINTED SAME COLOR BOTH SIDES * REPAIR/REMOVE/REPLACE EXIST HARDWARE AS REQ'D TO MATCH SET INDICATED AT EXIST. DOOR DOOR / FRAME SCHEDULE REF.: A2.1 SOURCE: 01 1/2"=1'-0" 0 0 0 c m M � T (D o o O 0 t t 12 L c }0)CN 0 _r 3: r N E 3 CV Z CV � V Q) H _ �c E " (D O p CV-0 -C = cn w Z i- 3 g N io (D N in r Z !- LL Architect: James License It: 00159 ri m J J ■ m QU Gz � � 06 z (/) ❑ ❑ . QW 0 0�0 0 --� w o UC' < �°j ~� W (� UWLl 0-U) U w�O E- . ,LL �Z LLI = OWU) i'a `Nv ,w Aw Q z Q� 0 Q 08 ldOo wW Eta Z .� DISTRIBUTION: DATE: PERMIT 08/13/04 3BBLM J�OB#. PETCO P.M. JOB # 7V%1,5 DRAWN: CHECKED: __l MAWING mi E: DOOR SCHEDULE FINISH SCHEDULE DOOR TYPES Al 1 ] I _Z q� LC 0 w (j) w T h- z 0 w J H w 0 Y 0 w z 0 z_ 0 0 a 0 F-• 0 IL U) z 0 U) z w 0 w vi t- w gU_ tya Ow U � ow_ Q 0 zz OQ �w -0 0� ZU Ow ZU F- ol! U)Q w T a� w0 �z J } z� �a Uo 0a oa UJ �a z N vi Z0 OQ 1500 1470 1440 1400 23'-441 ' 52'-72 24'-22' PETCO/ LOGO SIGNAGE CONCEALED PLYWD. REF. AO.2 SEPARATE SHEATHING OR OTHER SOLID ( ANCHORAGE BEHIND BUILDING NOTE: BANNER ANCHORS AT COPING AND WALL PERMIT) SIGNAGE (05500) REF. TO 9/A6.1 & 1o/A6.1 COORDINATE ' "RAPET LOCATIONS WITH PETCO PROJECT MANAGER TOTAL ELEV. AREA 2,670 SQ. FT. T.O. PARAPET d421'-10" A.F.F.F D D.B.E. • EXTERIOR • . • . - STOREFRONT 12 .0. STOREFRONT NNW- - -" FIN FLR. FRONT ELEVATION 03 WINDOW WINDOW SHADES 15'-2" SHADES REF.: A2.1 SOURCE: 1/8" =1'-0" 35'-0" A.F.F. -- W. FARARET PETCO ROOFLINE W/ 1 /4" PER FOOT SLOPE MIN. 26 26'-8" A.F.F. :-8A.F.F. " T.O. IJAR7FE T RTU RlU ob 21'-10" A.F.F. .._ — _ 18'-4" A.F.F. 12'-0" A.F.F. ; DUMPSTE LQCATION.. seREEN T ' ".'-.. ADJACENT TENANT .WALL ' FF 0— — — 0'-0" FIN. FLR.r '-0" FIN. FLR., ob DOCK WELL � — — �/ -4'-0" A.F.F* LEFT SIDE ELEVATION 02 REF.: A2.1 SOURCE: 1/8" = 1'-0" 24" x 36" ACCESS HATCH PETCO ROOFLINE ❑ ❑ ❑ 2 '_ „ T.O. PARAP PETCO/LOGO SIGNAGE RTU RTU REF.AO.2 (SEPARATE — PERMIT) 18'-8 1 2" A.F.F. B.O. LT. FIXTURE �' ® — — — 18'-4"+ ALF 11'-0" A.F.F. R.W.L. R.W..L. •R.W.L. (TYP.) DUMPSTER LOCATION NOTE: W/ 6'-0" H. SCREEN a ELEVATIONS PROVIDED WALL FOR REFERANCE ONLY. TO BE REVIEWED UNDER A SEPARATE PERMIT 0'-0" FIN. FLR. 7/0, mi ..-..........................................................................................................................................................................................._............... _....._ . _ ...._......_...:......._._ ...._....................-............................................-................... .........0 -0 FIN. FLR r, REAR ELEVATION 01 REF.: A2.1 SOURCE: w r Archit Licen. ci J ct] J � m Q c :EzLIL 06 zU) �� < W 0 m n 0 .-a Q W o 0 ❑... (n Z U uJ.. �UJ� W� U w�0 a— w C.- z w 0w< H(1)U) a z O 9 LtV OD tW uj ct:U u� Z DISTRIBUTION: DATE: PERMIT 08/13/0.4 SBLM JOESiI PE'iC0 P.M. JOB tf DRAWN: CHECKED: MAWlNc ITLE: EXTERIOR ELEVATIONS A4. 1 C� z �q LC. ❑ w U) w 2 I- z w J w ❑ Y 0 w z Q z 0 0 IL 0 H 0 IL U) z 0 U) z w 0 w vi I- w 16 a4 ow V � U ❑ rn < ❑ U } z z OQ �w -0 zU o Fw- c� z z U FQ w z w� tail >0 z T a �o a OJ �a T F- 0z 0) BUILDING SECTION 11 REF.: A2.1 SOURCE: EL. VARIES EL. VARIES EL. VARIES T.O. JOIST / T.O. JOIST T.O. JOIST DEFLECTIO UNN R DEFLECTION NNER CAULK FRAMING PENETRATIONS DEFLECTION RUNNER CAULK FRAMING PENETRATIONS ON RETAIL SIDE ON RETAIL SIDE CROSS RUNNER STUD AT EACH CROSS RUNNER STUD AT EACH \45511�1� BRACING TYP. BETW. JOISTS (TYP. CAULK FRAMING PENETRATIONS BRACING TYP. BETW. JOISTS (TYP. FRAMING FOR ALL FULL HGT. ON RETAIL SIDE FRAMING FOR ALL FULL HGT. PARTITIONS PARALLEL TO JOIST SPAN) 45* CROSS RUNNER STUD AT EACH 45' PARTITIONS PARALLEL TO JOIST 3-5/8" x 20 GA. MET. BRACING BRACING TYP. BETW. JOISTS (TYP. \ SPAN) " FRAMING FOR ALL FULL HGT. 3-5/8 x 20 GA. MET. BRACING - - SECURE TO STRUCTURE 48" PARTITIONS PARALLEL TO JOIST SECURE TO STRUCTURE 48" O.C. W/ O.C. W/ CONT. RUNNER ON SPAN) CONT. RUNNER ON NON —RETAIL SIDE NON —RETAIL SIDE ONLY ONLY 5/8" GYP. BD. EACH SIDE ON " 3-5/8" x 20 GA. MET BRACING — - r 5/8" GYP. BD. ON 3-5/8" x 20 3-5/8 x 20 GA. MET. i SECURE TO STRUCTURE 48 O.C. _ TEK SCREW FASTENERS 12" O.C. FRAMING 16" O.C. w/ CONT RUNNER ON NON —RETAIL GA. MET. FRAMING 16" O.C. MAX AT BOXED HEADER SIDE ONLY TEK SCREW FASTENERS 12" O.C. (2) 8"x 14 GA. C—JOIST BOXED _ (2) 6" x 16 GA. C—JOIST BOXED SUSP. ACT. SUSP. ACT. MAX AT BOXED HEADER HEADER (18' SPAN, 22' TOTAL q HEADER (2) 8"x 14 GA. C—JOIST BOXED PARTITION HGT. LIMIT RETAIL OFFICE}`% HEADER (18' SPAN, 22' TOTAL PRE —SALES 102 5/8" GYP. BD. ON 3-5/8" x 20 113 ��'" 1 PARTITION HGT. LIMIT) HEADER END BEARS ON JAMB STUD PRE —SALES CLOSET 116 HEADER END BEARS ON JAMB GA. MET. FRAMING 16" O.C. _ SIM RETAIL 118 F101-0-1 STUD q 102 RETAIL ADOPTION AREA HM DOOR FRAME W/ NO STOPS, Af3. TEMPERED GLASS IN AL. 102;�j 103 5/8" GYP. BD. ON 3-5/8" x 20 AS SCHED. FOR DBL ACTING BREAK ROOM RETAIL;{. FRAME/OFFSET FRAME IN PARTITION GA. MET. FRAMING 16" O.C. DOOR 116 102 -Ass. i TO BE FLUSH W/FACE OF FINISH ON 5/8" GYP. BD. ON 3-5/8" x 20 1 "ROOM" SIDE. / GA. MET. FRAMING 16" O.C. PTD. 5/8" B—D INT. PLYWD. ON SOUND ATTENUATING BATT INSUL. C / WALL BUMPER GYP. BD. AT PRE —SALES ROOM IPTD. 5/8" B—D INT. PLYWD, ON 07210 WHERE SCHEDULED "PARTITION (10300) RETAIL SIDE } SIDE GYP. BD. AT PRE —SALES ROOM REF. A2.1 TYPES/ o o SIDE 16 GA. TRACK W/ HILT] X—DNI 32 16 GA. TRACK W/ HILT] X—DNI 32 16 GA. TRACK W/ HILTI X—DNI P8 POWDER ACTUATED FASTENERS 16 GA. TRACK W/ HILT] X—DNI 32 P8 POWDER ACTUATED FASTENERS 32 P8 POWDER ACTUATED 32" O.C. (ICBO REPORT NO. 2388) P8 POWDER ACTUATED FASTENERS 32" O.C. (ICBO REPORT NO. 2388) FASTENERS 32" O.C. (ICBO N 32" O.C. (ICBO REPORT NO. 2388) REPORT N0. 2388) EL. 0'-0" OIL EL. 0'-0" EL. 0'-0" EL. 0'-0" Ilk EL. 0'-0" FIN. FL. FIN. FL. FIN. FL. FIN. FL. FIN. FL. ADOPTION FIRST SECTION 05 FILTER ROOM PARTITION SECTION 04 INTERIOR PARTITION SECTION 03 INTERIOR PARTITION SECTION 02 SECTION @ WINDOW 01 REF.: A2.1 SOURCE: 1/2"=l'-O" REF.: A2.1 SOURCE: 1/2"=1'-0" REF.: A2.1 SOURCE: 1/2"=1'-0" REF.: A2.1 SOURCE: 1/2"=l'-O" REF.: A2.1 SOURCE: 1l2"=l'-0" c 0 N e rn ro o 0 CD 0 o 0 QD U j -Y R7 - 0) � U J-_ N E N N O 72 Z m n c co E 1, }}N O O N_ 7 Q N Lo fn ,- Z F- CfD f M� Architect: James License It: 0015`: J m J J J � CLi QU a �z LL� od Z Uj � > Qw J Q om�o 0� �W�o ��. , WW W0 Wp0 a. U) z z o O uj <L I— cn c) LL 0 00 WW [to �z N DISTRIBUTION: DATE: PERMIT 08/13/04 SBLMJ LW PETCO P.M. JOB N O t`MJ� T� DRAWN: CHECKED: MAW; THE BUILDING ELEVATION INT. WALL SECTIONS A5.1 vi 0 z Q w w T I- z Q w J fa- w Q Y 0 w T c� z 0 O fy IL 0 0 ry IL U) z 0 U) z w 2 O wuj g6 �a Ow Ua U Q U Q Q U � z z O< F- LL 0 z U Ow U f-- oz zry �Q u�w T w0 �z J T a U)o a0� oa f UJ T F- U) 0zz Ua • In 35'-0" A.F.F. T.O.PARAPET 27'-8" A.F.F. T.O.STEEL 26'-8" A.F.F. T.O.PARAPET BEYON 21'-11-1 2" A.F.F. D.B.E. 14'-3 1 2" A.F.F. B.O.SOFFIT 12'-0" A.F.F. T.O.STOREFRONT 0'-0" FIN. FLR. IV REF.: A2.1 SOURCE: ECTION RUNNER >S RUNNER STUD 0 EA. ,ING (TYP.) BETWEEN S. GYP. BD. ON 3 5/8" X �A. MET. STUDS 0 16" 0. '8" X 20 GA. MET. "ING- SECURE TO iCTURE 48" O.C. W/ RUNNER ON -RETAIL SIDE ONLY 3"X14 GA. )IST :D )ER SLIDING ZANCE i FRAME, AS _DULED 01 1/2"=1'-0" c 0 0 c vy U T a a) o 0 i, a CD s � � J � 0 CO N U Q" E Z j L O CQ U C CQ 0 O O N t Lo O va CfDv c� Architect: Jamey Co en License #: 00159Q3 7 J ca J J _j m QU d ® Lj od ZU) �> < w o C 1 � < ®__j Z WHO < P 0 _j Cl) Z 0 LL W W WD U w_j 0oC Cis Z Z O LL 0-OWQ F_ U) cn • V� a 0 a o Ou wW �Q DISTRIBUTION: DATE: PERMIT 08113/04 SBLM JOB# PETCO P.M. JOB # O O j�o DRAWN: CHECKED: ow►VMG nna EXTERIOR WALL SECTIONS A5.2 (6 (9 z 0 w U) w T F- z 0 w J i- w Q Y O w z (9 z 0 0 a a 0 F_ a O IL W Z 0 W z w 0 w w wZ �a ow U oU) Q0 W} zz oa �a 0 o� Z U Ow z pQ Xw wz >_F_ aX w F- >o J Z zQ U)0 �0� IL OJ U J �a 2 0z • wj E a) MET. ROOF PANEL, CO MET. RIDGE CAP CO METAL ROOFING PANELS ON BED END IN 6"x18 GA. MET, PURLINS 24" SEALANT ,�12" O.C. MET. GA NEO NE CLOSURE MET. GE CAP 4" 4" FLASH 3' ROOF MEMBRA P NCED MET. ANCHOR STRIP M RANE OFING ADHERE ROOF.0-F MET. CLOSURE MEMBRANE TO FLASHING CO FL NG ON 5/8" YWD. SHEATHING SHEET SEALANT OVER MET. ROOF PANELS y ADHERE MEMBRANE 26 -2 " E.I.F.S., TO 00- - ROOFING SHEET CONT. T OVER CONT. T.O.FRAMING 16 GA. GALV. ( ' 16 GA. GALV. I STL. PL. i STL. PL., OVER T. 0. E.1. F. S. 0 SECURE STARTER I CONT. CHANNEL FASTENED TO ` - CLEAT TO MET. FRAMING DOUBLE PURLIN MET. DECKING DBL. PURLI AT EAVE ® RIDGE TYP.FZ- I ADHERE i ROOF MEMBRANE ON 1 /2" .: MEMBRANE RETRO-FIT BD. ON 5/8" C-D 00 i ROOFING SHEET I EXT. PLYWD. SHEATHING (EXP.1) HE FLASHING OVER i T.O. FRAMING/ LA .1000/ T. 0. E.1. F. S. RIDGE CAP DETAIL 19 ROOF GABLE DETAIL 18 EAVE DETAIL 17 ROOF PARAPET DETAIL 16 REF.: A2.1 SOURCE: NO SCALE REF.: A2.1 SOURCE: 3"=1'-0" REF.: A2.1 SOURCE: 1 1/2"=l'-0" REF.: A5.2 SOURCE: 1 1/2"=V-0" 12" WIDE FELT UNDER JOINT MEMBRANE ROOFING UNDER COPING 6" WIDE JOINT COVER SET IN MET. COPING/REF. DET.12/A6.1 MET. JOINT COVER i TO 6" WIDE SET 811 CONT. MEMBRANE SEALING STRIP OVER COPING SEALANT, TYP. W/ 1 /2" GAP BETWEEN COPING SECTIONS HILT] X-CR54 P8 12" O.C. STAGGERED, C'SUNK WD. KG. TO MET. COPING ELASTOMERI ALANT PREFINISHED MET. v " ENSURE MIN. 1 MAS Y EMBED SEAL TO F FLASHING TH RIC AND MASTIC COPING W 0 STOP / MET. CO W T. HOOK STRIP, / " 1 FL MIN N BAR RANE FASTENERS �, Wp, BLOCKING 10 S LYWD. ON w Q SE " MEMB. BASE/ COUNTER- 20 GA. MET '- TENERS W/ NEOPRENE WD.HIMBON 2x > FING COUNTERFLASHING FLASHING FULLY ADHERED DECK CLOSURE - S 8n O.C. OOD BLOCKING, UNDER TO CMU 811 SEALANT " - COPING : �. WIDE FELT UNDERLAY AT COPING JOINTS MEMB. ROOFING FLASHING FIBER CANT STRIP SET IN BITUMEN UNDER COUNTER- 1 /2" COMPRESSIBLE FILLER 6" 45 MIL. REINF. FLASHING (BUILT-UP ROOF ANGLE & ROOFING AND ANCHORAGE NOTES/REF. DET. 11/A6.1 FASTENERS 6" O.C. ONLY) PREFINISHED MET. EPDXY BOLTS 4,�' BOND CEMENT TYP. GUTTER . • - 1 /8"x 1" PREPUNCHED BOND BEAM & VERTICAL TERM. BAR SECURE 8" O.C./ RWC STRAPS L REINF./ REF. STRUC. O.C. VERT SEALANT AT ALL FINISHED EDGES 4"x REFINISHED - 3' " RWC 3' -0 PARAPET DETAIL @ ENDWALL 14 GUTTER DETAIL 13 COPING DETAIL 12 R0017ING DETAIL 11 REF.: A5.3 SOURCE: 1 1/2"=V-0" REF.: A5.3 SOURCE: 1 1/2"=V-0" REF.: A5.2 SOURCE: 1 1/2"=1'-0" REF.: A5.2 SOURCE: 1 1/2"=1'4' S. ST. EYE NUTBED ' GROUT SOLID CMU CELL HVAC ROOFTOP UNIT PROVIDE SECURITY BARS FOR ALL ROOF OPENINGS LARGER IN SEALANT AT CUP ANCHOR (R. i.U.) (OTHER EQMT. SIM.) [ %` TriAR 11 IN EITHER DIMENSION S. ST. FENDER WASHER LOCATION OR EPDXY IN PLACE ROOFCURB f ;:-;. % �. (rEXCEP T R.T.U.S) ON EPDM RUBBER 3 5/8" MET. FLASHING OVER 1.SIZE AND LOCATION OF FRAME WASHER ALIGN CUP ANCHOR MEMB. COUNTERFLASHING OPENING TO BE FURNISHED TO STE SUBCONTRACTOR BY CONTRACTOR. BED WASHER IN WITH FACE OF FINISH - SEALANT a4o °Q' CUP ANCHOR _ _J 2.FRAME�AN�GLE SIZES 6"x6" EPDM (05500) LOCATE �� 1 TYP. 0 TO 2 -0 L3x3x1/4 L4x3 F- �- '.q WITH HORZ. CROSS �' I I 2'-0" TO 5'-0" 1/2x5/16" o I I o :< 4 BAR a: 5-0" TO 10'-0" L5x3 1 /2x3/8" :. a WD. NAILER AT PERIMETERS OVER 10'-0" CONTACT .• N CORE DRILL MASONRY TO MEMB. ROOFING SYSTEM w ARCH./ENG. 3/16 L4x4x3/8" CLIP TYP. (4) - - - - MEMBRANE ROOFING 4. RECEIVE CUP 18 GA. METAL DECK VERIFY wi EQUIP. SUPPLIER SEALANT e m Y ANCHOR CLOSURE J CID 5/8" DIA. STL. BARS, MAX. S. ST. HEADLESS a• a ¢ ¢ ' : '" • w - J CQ SPACING 8" O.C. EA. WAY, WELD ALL CROSS -LAPS AND HANGER SCREW, SECURE - = AT ANGLE FRAME BUTT JOINT TO PLYWD/WD BLKG. SEALANT ROOF OPENING ANGLE J L REF. TO DETAIL 07/A6.1 FOR 911 FRAME / REF. DET. ROOF SIZES OF ANGLE FRAME 07/A6.1 JOISTS MEMBERS/ REF. MECH. FOR REF. (05500) FOR BANNER ANCHOR ASSEMBLY PRODUCT SOURCE ROOF OPENING SIZES BANNER ANCHOR AT PARAPET COPING 10 BANNER ANCHOR AT EXTERIOR WALL 09 ROOF CURB DETAIL 08 ROOF ANGLE FRAME DETAIL 07 SECURITY BARS PLAN DETAIL 06 REF.: A4.1 SOURCE: 6"=1'-0" REF.: A4.1 SOURCE: 6"=1'-0" REF.: A2.5, A0.2 SOURCE: 1 1/2"=V-0" REF.: A2.5, A0.2 SOURCE: N.T.S. REF.: A2.5, A0.2 SOURCE: 3/4"=1'-0" ,. LOADING DOC BOND BEAM/ REF. STRUC. � :..` SAFETY RAILING T.O. F INTERIOR F.O.M. EDGE OF DOCK LEVELER z ,: ; `' ' ' ` SYSTEM (07720) _ 1 T- 0 4 IN ATION (10300) „:.: INSIDE F.O.M. z 1aM PTD. PLYWD. -�_I I I _-:...t... �•: �� ,� STUDS 4 1 2 0 1" EAD / " „ L6x2 PTD. SAFETY YELLOW" 5„ 1 w/ w :;',:.;.:'::.`'• SEA TEA.10 �:.:. F CH I I a --PROVIDE CAGE NON -SHRINK GROUT LUSH HEAD i ` ::, ,.. H.M. 3"x 6"x 1 /4" BENT PL I IF 20'-0" z DIUS T.O. SIDE RAILS CLIP ANGLE TYP. LAG I LADDER HGT. GALV. L3 x 4 x 1 /4 W/ • .�: ,: o TO SOLID CONCEALED i 1 /2" DIA. x 4" L. OMINOUS COATING INSIDE EXT. H.M. FRAME LAYOUT LADDER SO TOP BLOCKING LADDER PTD. STUDS 8" O.C. - L6x2x 1/4"x 11' 4" W/ `' TO RECEIVE GROUT RUNG ALIGNS W/ T.O. ROOF I �� �� 2 x 3/8 PL. I "SAFETY YELLOW" / '' ROLLING 1/2 DIA. x 6 WELDED " STUDS 12 O.C. O 4" 1/2"x 12 GA. STL. .. � DOOR x5 STRINGERS TYP. ANGLE GUIDES PL 1/4"x 10" x 11'-4" GROUT SOLID / cl�PL./DECK CLOSURE AT ROOF HATCH OPENING 3 4" DIA. / I r � `� �. / FULL WELD TO L6x2 REF. STRUC. - (ALL SIDES) (DEFORMED) RUNGS I ROLLING DOOR FULL LENGTH C12x20.7 o I I / " GALV. 6 x 1 4 CONT. JAMB PL. LEG W LEG REMOVED W/ SEALANT EA. SIDE BENT CLIP ANGLE LAG I I CONCEALED WD. 2" 2" " I I FULL WELD TYP. EA. ANGLE EXIST. CONC. LOADING :r ,.�. �• • ✓/- 3 MASONRY ANCHORS }•�''�Y BLOCKING x x EXPANS BOLT I I 2 - GALV. L3 x 3 x 1 4 W / / DOCK •`` EA. JAMB TYP. ANG TO CONC. FL. I I r � 1/2" DIA. x 4"L. GROUT SOLID H.M. FRAME , DEFLECTION B I � FIN. FL. STUDS 8"O.C. DOCK BUMPER (BEYOND) RUNNER EXT. H.M. DOOR DETAIL 05 ROOF HATCH DETAIL 04 LADDER DETAIL 03 ROLLING DOOR JAMB DETAIL 02 DOCK LEVELER 01 REF.: A2.1, 01/A3.1 SOURCE: 1 1/2"=l'-0" REF.: A2.5. A0.2 SOURCE: 1 1/2"=V-0" REF.: A2.1 SOURCE: 1/4"=1'-0" REF.: A2.1 SOURCE: 3"=1'-0" REF.: A5.2 SOURCE: 1 1/2'=1'-0" C 0 m CD r_ a o }mg C"I N V (D rN EO Z N ti 0 Lu u� cfl E i O O O CNJ Q �� CL J cn zi-LL Architect: James Ien License it: 001590 0 m �U m QZ � :j i>> LL 06 Z (/) ry } QW 0 mho 0LL -� Z W �o U a" f¢ Z C) LL , W W W:D 0 Woa U) QZ - O W Ow< F_ U) (n N Q Z p0 WW =o (V DISTRIBUTION: DATE: PERMIT 08/13/04 SBLM JOB# PE'fC0 P.M. JOB# b �f© 7S DRAWN: CHECKED: EXTERIOR DETAILS A6.1 U) 0 2z_ w W w z w J I- w Y 0 w 2 0 z a 0 a 0 0 a z 0 Fn z w 0 Iw- w a< ow U� ❑ vi Q° zz 0 Q Fw �0 z� 0w U h- z I= Q Xw W = w� >0 Z Q J 2 d fn 0 a0� a o_j Oa EQI.iAI... 'A' EQUAL.. 'A 4y,T 1'% - l o" I Jl 1 .1 E ...-... ^, I. i CLOSET CAGES TYP. COUNTER REF. _ 1 - ----------------------- ::' < DET. 02/A8.2 =Y1 =- & 03/A8.2 F.D. TO BE FLUSH NO FLOOR/ Y; CABINET W/ HAIR SLAB RECESS AT FLOOR DRAIN- I I HWH ; I - - _ _ INTERCEPTOR F.D. TYP. FOR ALL FLOOR DRAINS "f' L- Y DRYER �A�E ROOM �-•: WASHER ui I 16 g PIA./ ..................... 30 x 3810. 2 - - - C. / 3. - „ I CLR. -n. IYXP. R.0 "ic: E A9.1 I WOMEN'S SLOPE DOWN I° ; - I PA E j1 / 2 ,) f I I \ 0 � II 2 �_ - ... I C.G. T.O.FIN.FLR. FLOOR SINK o o y_ DRYER " W/ STRAINER T.O. F.S. CORRIDOR WALL BUMPER THRU ROOF, 0 -0 0 -0'-1 "(TYP. AT 2) CONCEALED IN 3 11 1 !, 120 .36 x. I (10300) A9.2 ,;'...---------- PARTITION/REF. MECH. , 2 1;1 CORNER i 10 .. J . I �.,.. C.G.: C. GUARDS SLOPE DOWN ! I EYEWASH r ' I (10300) TYP. ! I N' STATION(10300) o - I ALL INTERIOR H.RING I SLOPEII DOWN ;,� WALL HR WALL IZ 2 PARTITION J i o I _' GROOMING ROOM wR c ..._ OUTSIDE OPF' 11 - - - CORNERS - ° y- Flo 6 R i ------ � � EXCEPT � 3 A9.1 1 MEWS •�r, 109 WHERE NOTED z :r' ^, 4 , u, ' • TUB ROOM 4 SLOPE DOWN ! - E .. L:... •..:\•\.................... ?:,; L�, ' "r; I :. I N �;'�• ; 105 �1'f I .:............. COUNTER REF. = Y I 3 01 1 I I 0 DET. 02/A8.2 ISI i O.F.S. - f ` � A9.2 / O' 1 " go IA. T.O.FIN.FLR. 2 I I „ 01_p" R H.R G 1. TOP OF FLOOR SINK ELEVATIONS ARE MINUS 1 WALL WALL CONCEALED (-1 ') BELOW FINISH FLOOR ELEVATION 0'-0". . �I GROOMIN - WOOD /� /ice COUNTER .=' BLOCKING ® ISOLATION R00 2. FINISH FLOOR ELEVATION AT ROOM PERIMETER IS (} I - - - - - �ci.1 u,) ' 24„ AND -�-- 01 116 CONSTANT (LEVEL) 0'-0", / / - 60 AFF I I 1 3 3. SLOPE CONCRETE FLOOR SO THAT EPDXY FINISH L' -' - ,Y, A9.1 - ------ _- ("FINISH FLOOR") IS 1/8" UNIFORM THICKNESS. START OF TI < REFRIG. = • o ._ ..,, ,_ .................... p� WAINSCOT 4. FLOOR SLOPE VARIES AS TO DISTANCE OF FLOOR -'8 1 "• - r' ��3.1 GROOMING, SINK OR "SWALE" FROM WALL. SAWCUT AND T10 RECEP R - _ REMOVE EXISTING CONCRETE FLOOR SLAB IN THIS mix I 104 < „. ROOM IN ITS ENTIRETY, AS REQ D. 8. > 9<< 03 5. FLOOR SINKS W/ REMOVABLE STRAINERS MUST BE : 1 A9 1 INSTALLED FOR PROPER DRAIN ACCESS AND STORE TUB ROOM /CAGE RM FLR FINISH DETAIL 13 STOREFRONT BUMPER OPERATIONS MAINTENANCE AT TUB ROOM. - ;'I )h'F:FI`:uI� ! ;r -03 SECURE TO AL < REF.: A2.1 SOURCE: 1/4" = 1'-0" SEE h:0 ; r #4 E 4 MULLION (10300) -Tf , TOWEL DI II WORK ROOM (10300) J 115 FLOOR PIVOT f.. i ,',8 i < �� .0.7...... < !! nFOR DOOR < _._ FREEZER. ;aFS.1 I ,J ; \ i 0.:Z µ v Of REF"ON f JF �J' E� r )r 7) ) CONCEALED SIM ::.f:: i IOTI:: k�{ < s...1... WOOD z µ ,l- I ; r \'. ,80' DIA.. / 5_._ BLOCKING ® .... i A. 5 -1 (��? x = < 24" AND Ad.1 x i < 60" AFF < < «. WALL BUMPER < 2'-4" HGT. SIM. ! 1 < i� J (10300) z 1 P'LAM. SHELF w I. •••S ,'� 5' --- ;" _ 1. CONTRACTOR FURNISHES AND W/ BRACKETS I C.G • < I � INSTALLS ALL BIRD ROOM .................. COMPONENTS 10300 A8. I ' ' j ( TYPICAL FLOOR ANCHOR -•.., 6'-0" A.F.F. N OR I <, ELEC < I "FULL LENGTH LOS - 2. REFER TO BIRD ROOM LOCATIONS i CORRIDOR I I 2" BLACK PANEL MOP HOLDER 20 " S ASSEMBLY INSTRUCTIONS", �; ITHRESHOLD B \- k, (10300) 114 I i c'TOP FURNISHED BY PETCO VENDOR, III E-AUTOMATIC a " i i I GROMMETS�: OFFICE FOR COMPONENT DIMENSIONS &= :a ; ; i MFR TYP. I ! ♦ ` ,I° ,..... C� 48 HGT. I O =- I I TYP. 48" I / x M I LOCATIONS - `r I .1 C.G. O.C. MAX. III I tt j ,� i11 -� 1�_I„ 1)-6,i 12.t,`�fl I P� .\1I. ::� // VESTIBULE I FLOOR I W`30Rx 36 -' `" - / ' - I ELEC. lJ 01 `;' f - 101 I ` C .FLR.:. ....._.._.. _ ). � / ,.... SERVICE AREA ... PANEL _ I'..._,;' I SHE F 1 A SINK I. -AREA.....- .... I LOCKERS L - -` ._. J INSTALL STORE 0J L _ - - - _ FIRE SUPPRESSION REFRIG. 06 SAFE WHERE ►- - - t�, I 3 2 I- .: I PIPING, A9.1 SHOWN ON HVAC / PETCO'S "FINAL ••- v .. EXHAUST DUCT, BREAK ROOM f w,_..._.- LAYOUT" STORE ELEC. POWER `� \ : CONDUIT MUST BE FIXTURE PLAN ' 1 " LOCATED TIGHT, TO t FIT INSIDE 12 DIA. �/� 08 .a ..--t; , NIIT �, , Eli 1 1 /2" (CLEAR INSIDE \/� r A8A --- I v - DIM.) DECORATION /2 PROVIDE BY PETCO SIM. Y BIRD ROOM 1. _ _ CLOSET ABV. TO BIRD ``',; 114 MOUNTED HITCHING RINGREFER r10 >,t i/? ;., 110 ROOM TO B.O. BAR = ` .;FE I�tQTE JOISTS TO DET. 10/A8.2 r� 2. DIMENSIONS SHOWN ARE TO ,. (F.O.F.) FACE OF FINISH WALL BUMPERS SUPPLIED W/ BIRD ROOM KIT 3. AUTOMATIC SLIDING ENTRANCE DOOR UNITS' 1. CONTRACTOR FURNISHES AND INSTALLS ALL BIRD ROOM PIVOTING "BREAKOUT" DOORS ICOMPONENTS (10300) ARE SHOWN DASHED. 2. REFER TO BIRD ROOM ASSEMBLY INSTRUCTIONS , FURNISHED BY 4. (2) 8 x 14 GA C-JOIST PETCO VENDOR, FOR COMPONENT DIMENSIONS & LOCATIONS BOXED HEADER (TYPICAL FOR ALL HEADERS ABV. 3' LARGE SCALE PLAN 05 OFFICE PLAN 04 BIRD ROOM PLAN & ANCHOR DIA. DET. 06 STOREFRONT) LARGE SCALE PLAN 01 E REF.: A2.1 SOURCE: 1/4" REF.: A2.1 SOURCE: 1/4" = 1'-0" REF.: A2.1 SOURCE: 114" = 1'-0" REF.: A2.1 SOURCE: 1/4" = 1'-0" (. Co c 0 �TT VI ca T y-°) 0 0 U X } co N U N C,'rl E 3 U U U N l } � T N .c o � w U) Z F u_ Architect: James Qohl n License It: 00159 3 J J in J .Jr, � Q V CD Ct: 2EzILL 06 ZU) ry Q W o 0-'LL 0 I- O 0_j zW�o Urnn- L..A..) (anzC)LL Lu w Wren OWoo ()-10 zzLL []W = O W Q F_ W W N • g 0 w 00 UU "' W LT (:1 �Z V,u) DISTRIBUTION: DATE: PERMIT 08/13/04 S`//BLLL/�M JOBN PETCO P.M. JOBS DRAWN: CHECKED: DMWING ME LARGE SCALE PLANS A7.1 U) 0 z a w w z w J w x 0 w 0 z a 0 a a 0 0 a (I U) z 0 U) z w 0 I- w �a ow UU °W U} zQ oLL �= 0 z0 0w os z0 Q w w� uu--. LL j 0. J } za -2 U)0 �a oa f U 0zz U Q • E SEALANT AT CONTACT AGAINST E I ' STOREFRONT, VERT. & HORIZ., TYP. BAKE METAL ALL SIDES E�TERIOR AL. STOREFRONT BRAKE METAL AT "11/A8.1 SIM" INSIDE F.O.F. ABV. BRAKE METAL ON FR. TR. PLYWOOD 0 ALUMINUM COMPONENTS (2) 3-5/8" x 1-5/8" x 12 GA. POST (1) LAYER 3/4" INT PLYWD. SUPPLIED W/ BIRD ROOM KIT BRAKE METAL ON PROVIDED BY CONTRACTOR, U THREADED ROD FLOOR ANCHOR PLY_W_D.__BL_K_G_.______ SECURE TO UNISTRUT W/ #10 SUPPLIED W/ BIRD ROOM KIT _ - ----- - SELF TAPPING SCREWS 12" O.C. UNISTRUT ROOF SYSTEM SUPPLIED ' • FLOOR ANCHOR EPDXY WITH BIRD ROOM KIT •' . • • °•: ' IN, A. .. ,, .PROVIDED BY CONTRACTOR M.D.F. TRANSOM ' d. r• .•• f A. ' ...,, IL " ----- x 3-1/2 . --- x 1/4 ^ � L3-1/2 I Z SUPPLIED WITH BIRD 3" FLOOR ANGLES ROOM KIT 1. CONTRACTOR FURNISHES AND INSTALLS ALL BIRD ROOM AUTO SLIDING 4' BIRD ROOM KIT PURCHASED COMPONENTS (10300) DOOR UNIT BY CONTRACTOR, ASSEMBLED SEAL NT TYP. & INSTALLED BY CONTRACTOR " " 2. REFER TO BIRD ROOM ASSEMBLY INSTRUCTIONS", FURNISHED 12" X 2-34" EXPANSION BOLT / / (10300) BY PETCO VENDOR, FOR COMPONENT DIMENSIONS & LOCATIONS (2) SLOTTED GALV. L 3-1/2 x 3-1/2 x AUTOI DOOR I A71 1/4 x 3 FLOOR ANGLES UNIT BIRD ROOM FLOOR ANCHOR DETAIL 17 STOREFRONT PLAN DETAIL 16 REF.: A2.1 SOURCE: N.T.S. REF.: 04/A3.1 SOURCE: 3"=1'-0" AL. STOREFRONT 21/4• 21/4° AL. STOREFRONT AL. STOREFRONT SEALANT TYP. L3-1/2" x 3-1/2" x 1/4" x WD BLKG.TYP. ' SUSP. ACT. PROVIDED BY CONTRACTOR SUSPEND FROM .;: 3 FLOOR ANGLES L-TRIM & SEALANT ' UNISTRUT (2) 8"x 14 GA. C-JOIST BOXED HEADER 3/8" TEMPERED GLASS PROVIDED BY CONTRACTOR 5 " 5/8" GYP. BD. ON o BRAKE METAL ON U.: (08800) SILICONE BULLNOSE _ 3-5 8"x 20 GA. MET. / PLYWD. BLKG. � SEALANT TYP. SURROUND AT FRAMING ®16" O.C. AL. FRAME & AL. DOOR SUPPLIED WITH BIRD ROOM KIT TUB ROOM SIDE L-BEAD AND CAULK BULL NOSE TILE BRAKE METAL WD. BLKG. p Q 1/4" TEMPERED GLASS AT TUB ROOM (2) 3-5/8"x 1-5/8"x 12GA. CONT. PROVIDED BY CONTRACTOR (08800) SEALANT, 0 BOTH SIDES oo TO BOXED HEADER ABOVE SUSP. ACT. =, L3-1/2" x 3-1/2" x 1/4" " 1/4 SHIM n n 1/2 X 2-3/4 EXPANSION BOLT ¢ 3 FLOOR ANGLES 1. CONTRACTOR FURNISHES AND INSTALLS ALL BIRD ' ;;. z 2U THRU () SLOTTED GALV. L VESTIBULE AUTO SLIDING 4 ROOM COMPONENTS (10300) CERAMIC TILL. CERAMIC TILE `�' 3-1/2 x 3--1/2 x 1/4 x 3 SIDE DOOR UNIT 2. REFER TO "BIRD ROOM ASSEMBLY INSTRUCTIONS", FINISH ON FINISH ON TUB GROOMING ROOM ROOM SIDE o Z-• FLOOR ANGLES " EXrANSION BOLT FURNISHED BY PETCO VENDOR, FOR COMPONENT ,. SIDE _ ¢ � BRAKE METAL D GALV. L 3-1/2 x 3-1/2 x /SLOOR ANGLES DIMENSIONS & LOCATIONS BIRD ROOM SECTION DETAIL 15 INT. STOREFRONT HEAD/SILL DETAIL 14 VESTIBULE CORNER PLAN DETAIL 13 VESTIBULE SECTION DETAIL 12 STOREFRONT PLAN DETAIL 11 REF.: SOURCE: N.T.S. REF.: 04/A3.1, 01/A7.1 SOURCE: 3"= 1'-0" REF.: 11/A7.1 SOURCE:: 311= 1'-01, REF.: 01/A5.2 SOURCE: 3` V-0" REF.: 01/A7.1, 04/A3.1 SOURCE: 311= 1'-0" INTERIOR SIDE OF EXTERIOR (2) 3-5/8"x 1-5/8"x 120A. CONT. STOREFRONT 6 7/8" :' TO BOXED HEADER ABOVE * MOUNT WALL BUMPER TO " PTD. 3/4 MDF CAP AND SIDE TRIM, z 1/2" X 2-3/4" EXPANSION BOLT THRU (2) o HORIZONTAL MULLION IF WITHIN THE MIN./MAX. H TS. SHOWN EASE ALL EXPOSED EDGES ,. s SLOTTED GALV. L 3-1/2 x 3-1/2 x 1/4 x 3 -_-_-_ _-._ AL. STOREFRONT T.O. CAP w FLOOR ANGLES o BRAKE" METAL PROVIDE AL. SAFETY RAIL (08410) SEALANT TYP. I 3'-4" `. " " FOR WALL BUMPER MOUNTING TO WD BLKG.TYP. N PTD. GYP, BD, '.i' L-TRIM &CAULK TYP. J L3-1/2 x 3-1/2 x 1/4 x ¢ 3 EXTERIOR STOREFRONT IF THERE IS L-TRllvl &SEALANT T.O. STEEL POST L-TRIM ALL SIDES FLOOR ANGLES NO HORIZONTAL MULLION WITHIN THE OF OPENING o MIN./MAX. HGTS. SHOWN CORNER GUARD : I ' �� 3 -2-1 /2 �_ N o (TYP.) i ALIGN F.O. AL. �- o 1/4" POST AT END/ REF. DIET 05/A8.1 STOREFRONT w/ z w 'RETAIL' -SIDE PART111ON N `� F.O.F. TYP. ALL INTERIOR AL. STOREFRONT "' `v ' ALIGN 21/4' CAULK TYP. WALL BUMPER (10300) 71/2" •t I I AUTO SLIDING DOOR UNIT PROVIDE ENDCAPS AT SAFETY RAIL ENDS BRAKE METAL FIN. FLR. 31/2' WD. BLKG. TYP. ADOPTION AREA WALL CAP 10 INT. STOREFRONT JAMB DETAIL 09 VESTIBULE CORNER PLAN DETAIL 08 STOREFRONT BUMPER DETAIL 07 STOREFRONT PLAN DETAIL 06 REF.: 01/A7.1 SOURCE: 3"= 1'-0" REF.: 04/A3.1, 01/A7.1 SOURCE: 3"= 1'-0" REF.: ll/A7.1 SOURCE: 3"= 1'-01. REF.: 04/A3.1 SOURCE: 311= V-0" REF.: 01/A5.2, 04/A3.1 SOURCE: 31.= 1'4" 4 1/2" ____ __-T---- (2) 3 5/8" x 1 5/8" x 12GA. INSIDE F.O.F. MET STUDS AT LOW WALL I i HGT. WITH 5/8 GYP. BD. PTD. GYP. BD. CAULK TYP. EA. SIDE DOOR UNIT (ONLY) INTERMEDIATE BOTH SIDES (NOTCH STUDS L-TRIM ALL SIDES __ __ __ __ HORIZONTAL AL. SECTION AND FLOOR ANGLES I ) OF OPENING GYP. BD. L-TRIM " 1/2 RISER/CLOSURE BY DOOR UNIT MFR. 4-1/2" AL. BASE " HSS POST 2 1/2 x 2 1/2 x ON RETAIL SIDE, ALL SIDES __ ___ __ 3"x 6"x 20 GA GALV. MET. BACKING BED IN SEALANT TYP. PL. 24" O.C. VERT., BOTH SIDES TYP. T.O. FIN. FLR. w3'-3 1/2" HGT. OF OPENING SEALANT i WOOD PARTITION CAP ABOVE " SIDELITE (VESTIBULE SIDE) AL. SILL FLASHING ---------------------------4 CAULK FRP 1/4 SHIM (2) 3-5/8"x 1-5/8% 12GA. POST 1/2" THRESHOLD, (1:2 MAX. SLOPE) BY REINF. CONC. SIDEWALK W/ „ 20 GA. x 6 GALV. DOOR UNIT MFR. SEALANT BED 1/2" E.J. SEALANT & ' MET. BACKING PL. (2)GALV. L 3-1/2x 3-1/2x (EXTERIOR DOOR UNIT) COMPR. FILER o 1/2" u w 1 1 3/4 1 3/4 1 1/2 (2) STAGGERED FLAT PHILLIPS " 1/4x 3 SLOTTED ANGLES ENTRANCE MAT N r --- --- HEAD 3/8" DIA. x 2 3/4" (10300) Ll 1 i +1 i i SLEEVE ANCHORS TYP. EA. ANGLE --?- - WALL BUMPER (10300) - - - -- " " (1) 1/2 x 2-3/4 EXPANSION BOLT T 0. FIN. FLR. +-- , '.=t ON RETAIL SIDE w/ THRU (2) OPPOSING, SLOTTED STEELh4 Jill _____- N FASTENERS 6" O.C. -- - '- ANGLES (VESTIBULE SIDE) N HSS POST 2 1/2" x 2 1/2" x 5'-0" BASE MAX. DOOR OPENING HGT. 2 GALV. L 3-1/2" x 2-1/2" 1 4"x 2 1/2" ( ) / / / T.O. CONC. i i i DETAIL SHOWN AT INTERIOR AUTOMATIC SLIDING ENTRANCE DOOR / EXTERIOR FLOOR ANGLES L CONDITION SIMILAR. ADOPTION AREA WALL DETAIL 05 INTERIOR STOREFRONT SECTION DETAIL 04 VESTIBULE SECTION DETAILS 03 ENTRANCE DOOR SECTION DETAILS 02 STOREFRONT SECTION DETAIL 01 REF.: 01/A7.1 SOURCE: 311= 1'-0" REF.: 04/A3.1, A7.1 SOURCE: 311= 1'-0" REF.: 01/A8.2 SOURCE: 3"= 1'-0.1 REF.: 11/A7.1 SOURCE: 3"= 1'-0" REF.: 04/A3.1 SOURCE: 3"= 1'-0" c 0 Tn 3 C rn M 2 r N O U 0 QD Lo }MLO DO U N EO CID Z N ti 0 m ) c cfl E } � N n Lo C! vn,-Z[--LL_ Architect: Jam License It: 001 c(] ...J r ; m ILL OZ$ z > Q W 0 In 0 ILL '�J z Woo (� C L Q f-- o 0 z 0 LL w::) 0 U0� CL U) Q z zzz 0 oW. 0 W ZLL _ t__ (n (n Q z oa sd d6 I Wul �a DISTRIBUTION: DATE: PERMIT 08/13/04 SBLM JOBU PETCO P.M. JOB # a qo�5 DRAWN: CHECKED: INTERIOR DETAILS A8.1 0 (9 z 0 w w z 0 w w 0 Y 0 w T I- c� z a 0 a a 0 a 0 a IL U) z 0 Fn z w a N w U ry 0. o w U � o vUi Cl U} zz Oa w 0 Z 0 0w 0_ z0 I= Q Xw w= x �0 z Q J za U)0 as IL 0� U Q �z 0zz U Q • .7 .I := I EXST. CONC, SLAB ON GRADE JOINT FILLER (03300) OR CONCRETE CORNER GUARDS I PATCH (03310) IF REQ'D #48" GROUTED/EPDXY DOWELS 32" `:: ✓— COLUMN PTD. "M—BLUE" O.C. EA. SIDE OF TRENCH/NEW SLAB NOTE: J—BEAD &CAULK VENT STACKS MAX. SPACING BETWEEN GYP. BD. I 4" CONC. REINF. W/ W1.4xW1.4 WWF CONTROL JTS. ON A WALL PLANE ON 6 MIL POLY VAPOR BARRIER ON SHALL BE 30 FT. B.O. MET. COMPACTED FILL `" I I r • CONT. L—TRIM TYP. 5 8" GYP. BD. ON 6"x20 (1) LAYER 5/8" GYP. BD. EA. DECK T.O. GYP. / SIDE ON METAL STUDS ®16" : BD. & MET. o ' GA. MET. STUDS, FRAMING O.C. I STUDS (2) SLIP CLIPS (09260) TO ROOF DECK W TOP INTERIOR PAR11110N GYP. BD. ON EACH MET, STUD, SCREW D 'r..� / pn D p• 00 MET. FRAMING I WHERE PARTITION IS DEFLECTION TRACK, REF. I PARALLEL TO DECK FLUTES I TO DEEP LEG TRACK ONLY DET. 17/A8.2 5/8" GYP. BD. I PROVIDE 20" x 4" x 12 GA. DEEP LEG TRACK SCREWED o (0� SEALANT AT CONTROL JT. '• Z. D D ! ' I STL. PL. 24" O.C. (2 PL.'S TO MET. DECK ONLY 01 WATER LINES OPAQUE GLAZIN INSIDE F.O. BETW. JOIST) 2 TEKS ' PARTITION AS SCHED. DO (� FILM 08800 STOREFRONT SCREWS EA. FLUTE, MUST O�Oo O �"V 0 FILTERED WATER LINE ( �' I I NOT FASTEN TO DEEP LEG Q o I LOCATE TO CONTACT AT COORD. ALL D o 00 TRACK TRENCH SLAB o Q o POWER AND DATA BOXES I LEAST 1 FLUTE ON EACH I I ' BATT UL. NON I SIDE OF PARTITION 'r PARTITION RATED REMOVALS & O 0 THICKENED HAUNCH ' REFER TO PLUMBING AND ( 0) REPLACEMENT W/ O O n O AT MEETING JOINT ELECTRICAL DRAWINGS j MEP DRAWINGS O Q . 0 0 0�oTYP.`�b O —TYP. O VENT STACK COLUMN 20 TYP. GYP. BD. CONTROL JOINT 19 STOREFRONT PLAN DETAIL 18 DEFLECTION RUNNER SECTION DETAIL 17 CONC. SLAB/TRENCHING DETAIL 16 REF.: A2.1 SOURCE: 3"=1'-0" REF.: A2.1 SOURCE: 3/4"=l'-0" REF.: A2.1, A7.1 SOURCE: 3"=1'-0" REF.: A5.1 0 3"=1'-0" REF.: A1.2 SOURCE: 3"= 1'-0" MASONRY FASTENERS 1 HR. R TE ENCLOSURE (UL I I /--PVC 90' OUTSIDE CORNER Ne STAGGERED 12" O.C. 'ECURE COLUMN DESIGN X528) 1 LAYER OF 5/8" I OVER W/ POP —GYP. BD_ ON 1 5/8" MTL. STUDSfl1. 16 GA. 'KITCHEN I 4" DIAGONAL STRIPES PTD. ON CONC. FLOOR, COLOR "SAFETY YELLOW" (09900) TO 3'-0" MIN. FROM FACE OF FURTHEST ELEC. PANEL PROJECTION EXCLUDING PANEL DOOR SWING I& s NO I i L%Xll: X-XI. lLNsNNLNllm_ 6llqm&wllml INTEGRATED POWER & CONTROL MDP TEL. BD. ASSEMBLY KENNEL ROOM SIDE 6" MET. STUD "LADDER"RIVETS 1" FROM Epp ON M.R. GYP. BDNESTED MET . I ENDS, 8" O.C. VERTU . STUD "STRU 2" 0.0 NOSE ANT Z_ — — — — _ — — WD, CONT, BETW. COLS. OPENING E BLKG. FLUSH W/ FACE ,; COL. FINISH SECURE SIDE ON CEMENT BOARD IOISTURE BARRIER ON FRAMING ------ I STALL COLUMN 1 I OVER TIGHT TO FINS V.1.F. FLOOR, PROVIDE I DOLED SILICONE Lj%JL_L_ E I SEALANT BEAD I TUB ROOM SIDE •4' 00, 00, M' 4' 1.• .4. y' '•�' :•'• GRADE ST. STL. I COLUMN COVER (10300) x 48" HGT., W/ FINISHED TOP EDGE (POLISHED / ROUNDED, NOT — — — — — — — — SQUARE CUT L H.M. DOOR FRAME VC RIGID TOP ON (AL. SIM.) SECURE PVC MOUNTING 2 '1 /2" COLUMN COVER ASE SIDES W/CONSTRUCTION ADHESIVE, TYP. AND TEMPORARY PVC END CAP TYP. TYPICAL DOOR OR OUTSIDE CORNER I REMOVABLE �— — — — — — — TIES AS REQ'D PRIOR TO POP f— PVC RIGID TOP ON C LINE OF BACK OF FABRICATE L--------------J MEETING JOINTS AT RIVETS INSTALLATION PV MOUNTING PVC END CAP BASE TYP. TYPICAL OUTSIDE CORNER FACE OF `I' COLUMN FINISH STORE FIXTURES MID —WIDTH OF SQUARE/ RECTANGULAR COLUMN COVER, (OR INSIDE CORNER) WHERE WALL BUMPER ENDS TYPICAL I i ? OOK SIDE FLOOR STRIPING AT PRE -SALES 15 TUB ROOM OPENING PLAN DETAIL 14 WALL FIXTURE FURRING SECTION DET. 13 COLUMN COVERING DETAI 12 WALL BUMPER PLAN DETAIL 11 REF.: A7.1 SOURCE: 1/4"=l'-0" REF.: A7.1 SOURCE: 3"=1'-0" REF.: A2.2 SOURCE: 3"= 1'-0" REF.: SOURCE: 3"=1'-0" REF.: A2.1, A7.1 SOURCE: 311= 1'-0" WALL FINISH AS SCHED. ON 5/8 " FRP TO FLOOR ON M.R. CER. TILE ON CEMENT BOARD ON FRP TO FLOOR ON M.R. GYP. ��—�—CER. II TILE ON CEMENT BOARD GYP BD./ M.R. GYP. BD. GYP. BD. MOISTURE BARRIER BD, MOISTURE BARRI SILICONE SEALANT AT HOLE �— SEALANT ON MET. FRAMING ON MET. FRAMIN 1. FOR' P.LAM COLOR, REF, 06200 , ( ) PRE —DRILL 1 2" DIA. HOLE / AL. CAP TRIM (09660) SEALANT SEALANT I sz El;.:,: O,.', /A7.1 THRU CER TILE OR FRP • FINISH (WHERE APPL.) INTEGRAL FLASH COVE TOP EDGE TRIM BY AL. CAP TRIM SEALANT WALL MOUNTED S. ST. HITCHING WALL BASE EPDXY INSTALLER (09670) ;^ BY EPDXY INSTALLER �: RING (05500) " ViNYL SHEET 1 R (09670) VCT FLOORING 1. FOR P.LAM COLOR, REF. (06200) `'- PROVIDE (4) S. ST. SCREW + FLOORING (09650) FASTENERS AT EA. HITCHING RING (09660) :;_7 2x4 WD. BLKG. HORIZ. AT �� P.LAM. TOP/EDGE I HITCHING RING LOCATIONS WOOD OR PLASTIC — ON 3/4" PLYWD./ `� ,..... TRIM VCT/WALL FINISH w/ 1/2 " FILLET SUPPORT STRIP MELAMINE UNDERSIDE DIA. HOLE AT HITCHING RING, 2x4 COUNTERTOP SHELF BRACKETS 08710 FILL VOID w/ SILICONE SEALANT REST ROOMS, WORK ROOM TUB ROOM DETAIL CAGE ROOM DETAIL GROOMING ROOM DET)3/4" P. LAM. (06200) ON SUBFRAME SECURE TO 32 O.C./ SECURE TO MET. PARTICLE— CONT, CONCEALED FRAMING STUDS OR PROVIDE �\ EPDXY FLOOR MOUNTED HITCHING DETAIL EPDXY SCREED FLOOR 3/4" BOARD BLKG IN ADJ. CONCEALED CONCEALED (2) 6" x 20 GA. I RING IN 3/4" DIA. DRILLED CONC. TRIM (09670) BY VCT FLOORING ENDCAP PARTITION. MET BACKING PLATES PRIOR TO VCT EPDXY INSTALLER �, INSTALLATION (09670) Z 771,(4) 1 x4x3O" PTD. D—SELECT WD. P.LAM ON COUNTERTOP w/ BETWEEN SHELF BRACKETS AQUARIUM AREA DETAIL INTEGRAL 4" BACKSPLASH & RAISED RADIUS NOSING 2' .. 3" HITCHING RING DETAIL 10 VINYL / EPDXY FLOOR FINISH DETAILS 08 Y PTD. 3/4" WD. REF.: 02/A2.1 P.LAM ON BOTH QUARTER ROUND TRIM REF.: A7.1 SOURCE: 311= 114" SOURCE: 3"=1'-0" SIDES 3/4" PLYWD. ._ END BRACE REF. 04/A8.2 (SIM.) „ 1 1 SCALD GUARD I •-j- (15400) �5. P.LAM ON j P.LAM ON 4"W x 3/4" PLYWD. I 3/4" PLYWD. WALL P.LAM (06200) ON PLATE 3/4" PLYWD. 1 I -= I BRACE F �----- — — — t� LINE OF ACCESSIBILTY CLEARANCE (MAXIMUM 2" DIA. HOLE, .Y: THAT FIXED TYP. AT EA. BRACE OBSTRUCTIONS MAY EXTEND IN SINK P.LAM ON SPACE/PER ANSI A117.1) 4"W x 3/4" (3) PLYWD. WALL PLATE BREAK ROOM COUNTER SECTION REF.: l l/A8.2 SOURCE: 02 OFFICE COUNTER & SHELF DETAIL 1 1/2"= 1'-0" REF.: 01/A7.1 SOURCE: 01 1 1/2"= 1'4" C 0 r_ 0 O J 0 0)CO ,Nd U) U) CV CV N E N Z N LO O m V Cc: (1) � >° I--- U) � OL N 3 � � LO a� Cn z F-• LL Architect: James i'Coh" en License #: 001590Y J 00 J J _j m QU Z lJ 06 Z()* Ll❑ <W 0 m�o OLL —I Q Woo U� U)zU� I Ill W� �0 o UWoo 0—U)z— LL. OwQ F-- cn v) m :3 4 0 gU TO iWfro Nz in u) DISTRIBUTION: DATE: PERMIT 08113/04 SBLM JOB# PETCO P.M. JOB # O Yols DRAWN: ChIECKED; DRAWING ME INTERIOR DETAILS A8.2 I uj 0 z w In w Lz r z w J w Y O w 2 z a a 0 H 0 a IL U) z 0 U) z w 0 w I w_ U fy 0- Ow U C� U O (1) z ❑ } zz 04 t= w _0 z0 0w U F- C9 T z0 U) Q x w u}}] T W )0 Jz 2 �a �0 IL o� zU) ❑ 0< • WHEELCHAIR ACCESSIBLE EWC ,� MIRROR WIDTH REF STANDING (STOOPING) ACCESSIBLE EWC I ' "ACCESSORIES SCHEDULE" (10300) I a Q dm a cD I I a COI I I W Q m �- X 0 0 � ❑ a a OO Z — = Co J p •Q QJ e C9 X M _ M low •tom _ I Q : Z 00 Z io • X oQ d- � N o M ¢ �, Q, I ELECTRIC URINAL (IF TOILET SEAT TOILET SANITARY SOAP TOWEL MIRROR BABY WATER SCHED.) COVER TISSUE NAPKIN DISP. DISPENSER* CHANGING COOLER DISPENSER* DISPENSER* DISPOSAL 0 WORK STATION FRP BEHIND &SIDES OF (PETCO VENDOR)(PETCO VENDOR) ROOMS EWC/ REF. A7.1 (PETCO VENDOR) 1. SOME WASHROOM ACCESSORIES FURNISHED BY PETCO VENDOR / INSTALLED BY CONTRACTOR, REF./AO.2, 10300 2. CONTRACTOR TO PROVIDE CONCEALED WOOD BLKG OR 20 GA. MET. ACCESSORIES MOUNTING HGTS. BACKING PLATES AT ALL WALL MOUNTED WASHROOM ACCESSORIES. REF.: AT 1, A2.1 SOURCE: a 0) T BABY CHAP STATION �HANDBAG HOOK (WOMENS RESTROOM ONLY) FRP ACCESSIBLE TOILET FLUSH LEVER ON NON -WALL SIDE TYP. <bTyp. BABY CHANGING, STATION vc:vc ELEVATION 1 ELEVATION 2 ELEVATION 3 1. SOME WASHROOM ACCESSORIES FURNISHED BY PETCO VENDOR / INSTALLED BY CONTRACTOR / REF. AO.2, 10300 2 CONTRACTOR TO PROVIDE CONCEALED WOOD BLKG "' TOILET TISSUE DISPENSER SANITARY NAPKIN DISPOSAL (WOMENS RESTROOM ONLY) TOILET SEAT COVER DISPENSER ELEVATION 4 OR 20 GA. MET. BACKING PLATES AT ALL WALL WOMENS RESTROOM ELEVATIONS MOUNTED WASHROOM ACCESSORIES REF.: AT 1, A2.1 SOURCE: A nn rrnl rfl r Tn 11 rr ELEVATION 1 ELEVATION 2 1. SOME WASHROOM ACCESSORIES FURNISHED BY PETCO VENDOR / INSTALLED BY CONTRACTOR / REF. AO.2, 10300 2, CONTRACTOR TO PROVIDE CONCEALED WOOD BLKG. OR 20 GA. MET. BACKING PLATES AT ALL WALL MOUNTED WASHROOM ACCESSORIES 3/4" P.LAM ON PLYWD. CONCEALED - SHELF BLKG. P.LAM ON 3/4"4"06" SHELF SUPPORT BRACKETS PARTICLEBOARD (08710) 32" O.C. ON (06200) CONCEALED BLKG. W/4 COATHOOKS 6"O.C. PTD. GYP. BD. ELEC. PANEL (08710) PTD. GYP. BD. (4) 1 x430" PTD. T.O. COUNTER OP _ D-SELECT WD. BETWEEN SHELF Eo o / BRACKETS 4'-0" 4'-0° 3'-6" N 3'-6° / CV / L 0 FILE CABINET VB ELEVATION 1 ELEVATION 2 SPACE ELEVATION 1 VB OFFICE ELEVATIONS 08 REF.: A7.1, A2.1 SOURCE: 1/4"=1'-0" CONCEALED 2x4 WD. BLKG. 12"x72" MELAMINE IND. FRP REFER TO ELECTRICAL SHELF AT 6'-0" HGT. DWGS. FOR CRITICAL TOWEL DISP. W/BRACKETS 16" O.C. �� - `' OAP POWER LOCATIONS ............. ................ ................. . ... ... ................ ............ . .... . ..... .... .. A2' DISP. ....... . I ............ ............................... ................................ ...... ............................... ..... ............. .. ........, ............... .. ... 7.7.1.1.1.7..1.1.1.1 .. 7.7 .. .............. . . '.f:......... ...................... ......... ................................ ..... -0°.......... ..... ......... ... ............................. ..... .............................................................................. . ............ ........... . ......... :.:�. 30 30 71.. . R = . . ! SINK. ....... . .—.._.._.._._.—...... 7 / ......... 3 FRP DIVISION MOULD FILLER VSB TYP. AT PANEL JTS. AT CAB. ELEVATION 1 ELEVATION 1 ELEVATION 3 ELEVATION 4 MENS RESTROOM ELEVATIONS REF.: A7.1, A2.1 SOURCE: 12" D. WALL CABINETS W/ ADJ. SHELVES (06200), PROVIDE SURFACE MTD. BLKG. INTEGRAL COUNTERTOP/ 4" BACKSPLASH & RETURN (06200) ,,--PTD. GYP. BD. 4'-0" SOAP DISP.— CONVENIENCE - SINK n 15711 16 1/4"=1'-0" 1 FILLER �B i � SCALD 30" MIN. CLEAR FINISH GUARD 0? SPACE UNDER COUNTER ELEVATION 2 ELEVA11ON 3 (KNEE SPACE) BREAK ROOM ELEVATIONS 06 REF.: A7.1, A2.1 SOURCE: 1/4"=1'-0" 12" D. WALL CABINETS W/ ADJ. SHELVES (06200), PROVIDE SURFACE MTD. BLKG. IAITE•nDAI r%nl IAITE*DTnn / t7G'FrD Tr) CI Cr%TDlr%AI r)UIPQ ELEVATION 2 ELEVATION 3 WORK ROOM ELEVATIONS 03 ISOLATION ROOM ELEVATIONS 01 REF.: A7.1, A2.1 SOURCE: 1/4"=1'-0" REF.: A7.1, A2.1 SOURCE: 1/4"=1'-0" c 0 U) c rn co v _0 0 00 _w T (o U Lo CO V C 3 N E -Nj- Z to O N N w O O N -0 0 N Lo (D (D co r Z LL Architect: Jamek Cohn I License #: 001590 J Co Jr, J J m Q CJ a LL Z u) Cr Qw o mho A O—� Z W D0 c<nz° W� �UWO o woo a. Cn z z U- �:5Z W 0-0U)U) N •'� m a 0 8 ao =w w a:o IL DISTRIBUTION: DATE: PERMIT 08/13/04 SBIM JOBtt PETCO P.M. JOB It D O DRAWN: CHECKED: INTERIOR ELEVATIONS A9.1 0 z �Q 0. ❑ W U) W T F- z w J W Y fy 0 W T F- 0 z a 0 a a 0 a 0 ry I U) z 0 U) z w 0 I-- w U � 0- oW U � ❑w Q° W� zz OQ �w — 0 z U 0w U T z� ►= Q XW W = } LL u- 0�F W 0 �z is �a a� �a U) • CONT. CONCEALED BLOCKING WALL MTD. HITCHING RING REF. DET. 10/A8.2 SURFACE MOUNTED EYEWASH STATION WRAP OPENING W/BULLNOSE 1-2 '-ou o 4T, T.G. SF05 14 CT CONT. CONCEALED BLOCKING WRAP OPENING — W/BULLNOSE WALL MTD, HITCHING RING SURFACE MTD. EMERGENCY REF. DET. 10/A8.2 EYEWASH (10300) CT 7 �ou 101 0 0 o T. G, , r r OS EPDXY 6" EPDXY 6" EPDXY 6" �RoXY :-D� Fi, ELEVATION 2 ELEVATION 1 TYP. ELEVATION 3, ELEVATION 4 ELEVATION 5 ELEVATION 6 TUB ROOM" ELEVATIONS 11 REF.: AT 1. A2.1 SOURCE: 1/4"=1'-0" 21" D. STORAGE CABINET 12" D. WALL CABINETS w/ ADJ. FRP INSIDE CORNER MOULD TYP. W/ADJ. SHELVES (06200) SHELVES (06200) PROVIDE SURFACE MTD. BLKG. FRP DIVISION MOULD TYP. FRP vvBULLNOSE TILE OPENING W/ ELEC. PANEL FRP AT PANEL JTS. TILE 1 FILLER ::': ;:::::` ;:`:: :'::' ::"::? ::'::::.';:':::'.': ..........................................................:......................................................................................................................................... ................................................................................................. .................................................. ........................... / .............. ..................... .............................. ... . 1 W 0 0 N i ............................... ............ .............................................................. ... � T � L ..... .......... :: 5 -0 77}} Y} \ / i FRP 6" OAT CAB. EPDXY " LEPDXY 6 �..... HAIR INTERCEPTOR IN PLASTIC HWH EPDXY 6 ELEVATION 1 PAN IN CABINET W/ OVERFLOW DRAIN ELEVATION 2 ELEVATION 3 TYP. 2 ADJ. SHELVES TO FLOOR/ REF PLUMBING ELEVATION 4 CAGE ROOM ELEVATIONS 06 REF.: A7.1, A2.1 SOURCE: 1/4"=1'-0" RAISED CEILING AT GROOMING RECEPTION, BEYOND PTD. GYP. //VWALL MTD. I PTD. GYP. BD. HITCHING RINGS I BD. REF. DET. 10/A&. I /I all kw L_ ■I'NOVA .■■■■!■■■1.,■■r.■ PH ■■►■■■■■■■■0,11 ■■■■■ OpEN�Du IN�O ,I II III ■■■■■■■■II ■■■■�1 CT WAINSCOT (REPEATING COLOR PATTERN) ELEVATION 2 (y) WAINSCOT (REPEATING COLOR PATTERN) WALL MTD. BULLNOSE C.T. HITCHING RINGS TYP. REF. DET. 10/A8.2 PTD. GYP. BD. CT T:G. , ... ...... .. ....... C :.: _ N CONT. CONCEALED FIELD TILE AT BLKG. BOTTOM/NO COVE ELEVATION 3 TRIM, TYP. ELEVATION 4 GROOMING ROOM ELEVATIONS REF.: A7.1, A2.1 SOURCE: C.T. —1 C.T. —2 01 1/4"=1'-0" c 0 0 c rn M v r-- 0 0 o 0 t, 0 0 QD U y Lo J 0 '.0 moo Y W CD N U w N o N Z N r U LYl C co E � Nxx Lo (D U cu (q r Z F— Li - Architect: James Vohen License #: 001543 / J m Ju m -- w 06 z (n 0- 0 Qw amo O� z wDo fU) ZOU w wZ) o Uw OJ0 w U zz0 Cn w LL 2z O w oar H N N Q $ 0 LL 08 00 W W ao N 4L Ol VJ DISTRIBUTION: DATE: PERMIT 00113/04 SBLM JOB}t PELGO P.M. JOB k o Yo 5 DRAWN: CHECKED: INTERIOR ELEVATIONS A9.2 INTRODUCTION A. PURPOSE THIS SHEET PROVIDES SOME BACKGROUND INFORMATION ON WHAT INFLUENCED THE DESIGN SHOWN ON THESE DOCUMENTS. ALTHOUGH SOME INFORMATION CONTAINED HEREIN APPLIES TO A SPECIFIC TRADE, IT MAY PROVIDE SOME INSIGHT TO OTHER TRADES. B. DISTRIBUTION THE PME SHEET SHOULD BE DUPLICATED AND ISSUED TO THE PLUMBING, HVAC AND ELECTRICAL SUBCONTRACTORS ALONG WITH THEIR RESPECTIVE SPECIFIC TRADE DRAWINGS, SOME PETCO VENDORS MAY ALSO BENEFIT FROM THIS INFORMATION. SPECIAL EMPHASIS, CONCERNS, AND LIMITATIONS A. CONSTRUCTION CIRCUITING - THE BUILDING CIRCUITING AND WIRING INCLUDES SOME SUBTLE YET IMPORTANT FEATURES. DO NOT DEVIATE FROM THE WIRING SHOWN WITHOU"r SPECIFIC PERMISSION FROM THE PETCO PROJECT MANAGER. MOUNTING - NO EQUIPMENT SHALL BE MOUNTED DIRECTLY TO THE UNDERSIDE OF THE ROOF. EQUIPMENT - LONG LEAD ITEMS MUST BE ORDERED PROMPTLY TO ENSURE TIMELY DELIVERIES. B. COMMUNICATION NOTIFICATION - THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY UPON DISCOVERY OF A PROBLEM OR CONFLICT, THE CONTRACTOR SHALL PROMPTLY IDENTIFY ONE OR MORE PROPOSED SOLUTIONS BUT SHALL NOT PROCEED UNTIL SO AUTHORIZED. COORDINATION - COORDINATE THE LOCATIONS AND ORIENTATIONS OF ALL EQUIPMENT WITH OTHER TRADES. C. LIMITATIONS PENETRATIONS - ROOF AND WALL PENETRATIONS SHALL BE LIMITED TO AREAS IDENTIFIED ON THE DRAWINGS. NO DEVIATIONS SHALL BE MADE WITHOUT WRITTEN CONSENT OF THE ARCHITECT. LOCATIONS - EQUIPMENT SHALL BE LOCATED WITHIN A REASONABLE DISTANCE OF THE LOCATIONS SHOWN. INTERRUPTIONS - IF APPLICABLE, COORDINATE ALL DISCONNECTIONS AND INTERRUPTIONS OF PLUMBING, HVAC, FIRE SUPPRESSION, ELECTRIC AND FIRE ALARM SYSTEMS WITH THE BUILDING OWNER. A SCHEDULE OF INTERRUPTIONS AND SHUTDOWNS SHALL BE SUBMITTED TO THE OWNER AND APPROVAL RECEIVED TWO WEEKS PRIOR TO ANY ANTICIPATED INTERRUPTION. PROVIDE BUILDING -WIDE FIRE WATCH DURING ANY FIRE ALARM SERVICE INTERRUPTION. REACTIVATE FIRE ALARM SYSTEM AT THE END OF EACH WORKING DAY. D. CONTRACTORS' RESPONSIBILITIES PERMITS - EACH SUBCONTRACTOR SHALL SECURE AND PAY FOR ALL REQUIRED PERMITS AND SHALL ARRANGE ALL REQUIRED INSPECTIONS FOR WORK UNDER HIS TRADE. EXISTING CONDITIONS - EACH SUBCONTRACTOR SHALL FAMILIARIZE HIMSELF WITH EXISTING CONDITIONS TO ADEQUATELY AND ACCURATELY BID, BUY AND CONSTRUCT THIS PROJECT, SOME EXISTING CONDITIONS ARE HIDDEN CONDITIONS. WHEN ENCOUNTERING SUCH CONDITIONS DURING CONSTRUCTION WHICH REQUIRE DEVIATION FROM THE DOCUMENTS, THE CONTRACTOR SHALL SUBMIT A REQUEST FOR INFORMATION (RFI) FORM, WHICH CAN BE FOUND IN THE PROJECT MANUAL. THIS FORM SHALL BE ACCOMPANIED BY ONE OR MORE PROPOSED SOLUTIONS. THE INTENT IS TO DEFINE A SCOPE OF WORK FOR THE SUCCESSFUL CONTRACTOR TO EVALUATE AND REPORT ON THE EXISTING CONDITIONS SO THAT ANY ADJUSTMENTS TO THE PROPOSED SYSTEM CAN BE REVIEWED, APPROVED AND RESOLVED PREFERABLY PRIOR TO COMMENCEMENT OF WORK AND CERTAINLY BEFORE THE COMPLETION OF THE CONTRACT. COORDINATION - EACH CONTRACTOR/SUBCONTRACTOR SHALL COORDINATE HIS WORK WITH ALL OTHER CONTRACTORS AND FIELD CONDITIONS. COORDINATE ALL ROOF PENETRATIONS WITH ROOFING SUBCONTRACTOR, MAINTAINING ROOF WARRANTY IF APPLICABLE, OWNER -SUPPLIED ITEMS (OSI) - ALL CONTRACTORS/SUBCONTRACTORS SHALL VERIFY REQUIREMENTS BEFORE PROCEEDING WITH THE WORK. SIGNS - FINAL SIGN LOCATIONS AND CONNECTIONS SHALL BE COORDINATED WITH THE SIGN CONTRACTOR, FIXTURE PLAN - VERIFY LATEST FIXTURE PLAN PRIOR TO INSTALLATION OF LIGHTING, DEVICES, ETC., WHICH DEPEND ON EXACT LOCATIONS OF STORE FIXTURES. SUBSTANTIAL COMPLETION - MAKE FINAL CONNECTIONS AND PERFORM STARTUP OF EQUIPMENT FOR COMPLETE AND OPERATIONAL BUILDING UPON COMPLETION. REFER TO ARCHITECTURAL PLANS FOR RESPONSIBILITIES MATRIX. E. STANDARDIZATION PROTOTYPE - THIS PROJECT IS NOT ONE OF A KIND. IT IS APPLYING SOME CHARACTERISTICS OF A PROTOTYPE DESIGN TO THIS SITE IN ORDER TO MAINTAIN STANDARDIZATION. ALSO, SOME DESIGN DECISIONS WERE BASED ON THE OWNER'S PAST EXPERIENCE. THEREFORE IN SOME WAYS THIS PROJECT REQUIRES STRICTER ADHERENCE TO THE DOCUMENTS THAN NORMAL PROJECTS. PRODUCT STANDARDIZATION INCLUDES: SECURITY SYSTEM POINT -OF -SALE (POS) SYSTEM SUPPLY ROOM SINK FIRE ALARM SYSTEM HVAC ROOFTOP UNITS WASHER & DRYER SOUND SYSTEM TELEPHONE SYSTEM LIGHTING FIXTURES & LAMPS INTEGRATED POWER & CONTROL ASSEMBLY PLUMBING FIXTURES FUNCTIONAL STANDARDIZATION INCLUDES: AUTOMATIC INDIVIDUAL CONTROL OF HVAC UNITS AUTOMATIC GROUP CONTROL OF INTERIOR LIGHTING AUTOMATIC GROUP CONTROL OF OUTDOOR LIGHTING AUTOMATIC GROUP CONTROL OF CERTAIN POWER F. SPECIAL PURCHASING OR CONTRACTS GENERAL REFER TO ARCHITECTURAL DRAWINGS FOR ITEMS NOT NECESSARILY FURNISHED BY CONTRACTORS BUT HAVE RELATED RESPONSIBILITIES. THESE ITEMS MUST BE INTEGRATED INTO THE BUILDING CONSTRUCTION SCHEDULE (ORDERING, SHIPPING, INSTALLING) AS IF THEY WERE PROVIDED IN TOTAL BY THE CONTRACTOR, REFER TO PROJECT MANUAL FOR PETCO VENDORS' NAMES, CONTACTS, AND PHONE NUMBERS. CONTRACTOR PROVIDED / CONTRACTOR INSTALLED THE FOLLOWING ITEMS ARE FURNISHED BY THE CONTRACTOR THROUGH A NATIONAL ACCOUNT AGREEMENT BETWEEN PETCO AND THE VENDOR AND INSTALLED BY THE CONTRACTOR: HVAC ROOFTOP UNITS LIGHTING FIXTURES INTEGRATED POWER & CONTROL ASSEMBLY AND LOOSE ELECTRICAL PANELS & CONTROLS. SOME CODE. AGENCY. & REFERENCE STANDARDS INFORMATION A. GENERAL ENTIRE INSTALLATION SHALL COMPLY WITH ALL LOCAL AND STATE CODES AND OTHER AUTHORITIES HAVING JURISDICTION. THE INSTALLATION SHALL BE IN ACCORDANCE WITH ALL SEISMIC REQUIREMENTS. WHERE PERMITTED BY CODE, PLASTIC WASTE & VENT PIPING CONFORMING TO IAPMO AND ASTM MAY BE USED WHEN CONCEALED BELOW FLOOR SLABS OR IN WALLS & PARTITIONS. SUPPORT PIPING IN ACCORDANCE WITH THE PIPE SUPPORT SCHEDULE OR PER LOCAL REQUIREMENTS, WHICHEVER IS MORE STRINGENT. NO PLASTIC PIPE MAY BE INSTALLED IN AREAS CONSIDERED TO BE A PLENUM. PROVIDE PROPER TRANSITION FITTINGS BETWEEN PIPES OF DIFFERING MATERIAL. B. APPLICABLE CODES AND REFERENCES: ALL STATE AND LOCAL CODES AND ORDINANCES, APPLICABLE EDITION NFPA 13 - STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS NFPA 54 - NATIONAL FUEL GAS CODE NFPA 70 - NATIONAL ELECTRICAL CODE NFPA 90A - AIR CONDITIONING AND VENTILATING SYSTEMS ASHRAE HANDBOOKS - AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR CONDITIONING ENGINEERS SMACNA HANDBOOK FOR DUCT CONSTRUCTION C. ACCESSIBILITY APPLICATION - THESE DOCUMENTS REFLECT THE DESIGN PROFESSIONALS' INTERPRETATION OF THE APPLICABLE ADA REQUIREMENTS AND OTHER KNOWN FEDERAL, STATE AND LOCAL LAWS, RULES, CODES, ORDINANCES AND REGULATIONS AS THEY APPLY TO THIS PROJECT. EXISTING CONDITIONS - ALL NEW WORK SHALL BE IN ACCORDANCE WITH THE AMERICANS WITH DISABILITIES ACT OR THE APPLICABLE BARRIER FREE CODE, WHICHEVER IS MORE STRINGENT. D. ANIMAL WELFARE ENVIRONMENT - SOME AREAS OF THE BUILDING HAVE SPECIFIC PROVISIONS FOR TEMPERATURE AND/OR LIGHITNG CONTROL. SCHEDULE - THERE ARE NO OVERNIGHT STAYS FOR ANIMALS OTHER THAN THOSE FOR PURCHASE, SUCH AS FISH SMALL ANIMALS (SUCH AS HAMSTERS AND GERBILS) AND REPTILES. DOCUMENTS A. DRAWING ORGANIZATION AND PRESENTATION: DRAWING LIST - REFER TO ARCHITECTURAL DRAWINGS FOR DRAWING LIST HOW NOTES ARE USED GENERAL NOTES - ONE OR MORE IN LIST FORM WHICH ARE NOT INDICATED SPECIFICALLY ON A PLAN, SECTION, ELEVATION OR DETAIL. NOTES FOR THIS DRAWING - GENERAL NOTES LOCATED ONLY ON THE DRAWING THAT APPLIES. KEY NOTES - USED IN LIEU OF STANDARD NOTES WHERE THEY IMPROVE READABILITY, KEY NOTES ARE GATHERED TOGETHER AND LISTED COLLECTIVELY ON THE DRAWINGS ON WHICH THEY ARE LOCATED. MISCELLANEOUS TERMS - THE TERMS 'SHEET', 'DRAWING' AND 'PLAN' ARE USED INTERCHANGEABLY. THE TERM 'PROVIDE' MEANS 'FURNISH - AND INSTALL'. SCALE - PRINTING OF THE PLANS IS OFTEN REDUCED, SO A GRAPHIC SCALE IS PROVIDED ON EACH SHEET. DO NOT SCALE ANY DRAWINGS. ADDENDA & REVISIONS - SOME ADDENDA AND REVISIONS ARE IDENTIFIED ON THE DRAWINGS USING A NUMBER IN A TRIANGLE. THE NUMBER IN THE TRIANGLE LINKS TO THE REVISION BLOCK IN THE TITLE BLOCK SECTION. SOMETIMES THE MOST RECENT CHANGE IS CLOUDED TO PROVIDE INCREASED CLARITY. B. SPECIFICATIONS TECHNICAL SPECIFICATIONS AND RESPONSIBILITIES ARE INCLUDED IN THE PROJECT MANUAL. C. COORDINATION STORE FIXTURES, FURNISHINGS, AND EQUIPMENT SHALL BE INSTALLED AND LOCATED IN ACCORDANCE WITH A STORE FIXTURE LAYOUT PLAN PROVIDED AT THE TIME OF DELIVERIES TO THE JOB SITE OF STORE FIXTURES AND FURNISHINGS. FINAL LOCATIONS MAY VARY FROM AS SHOWN ON THE FLOOR PLANS IN THIS SET OF DRAWINGS. GENERAL NOTES A. ALL TRADES 1) RESPONSIBILITIES & COORDINATION: REFER TO PROJECT MANUAL FOR RESPONSIBILITIES REGARDING LOCAL PERMITTING AND UTILITY COMPANY REQUIREMENTS, FEES AND INSPECTIONS. SEE ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION & DETAILS REGARDING ROOF CURBS AND PENETRATIONS, INCLUDING INSULATING, FLASHING, COUNTERFLASHING & SEALING, AND COORDINATE WITH THE ROOFING SUBCONTRACTOR. ALL EQUIPMENT SHALL BE FURNISHED WITH SHOP DRAWINGS, INSTALLATION GUIDELINES, MAINTENANCE MANUALS, SCHEDULES, TAGS, AND LETTER OF GUARANTEE IN A BINDER (THREE-RING) WITH TABS. ALL EQUIPMENT SHALL BE INSTALLED IN CONFORMANCE WITH THESE DOCUMENTS AND THE EQUIPMENT MANUFACTURER'S RECOMMENDATIONS EACH CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING AND PATCHING OF ANY WALLS, ROOF, OR FLOOR DURING CONSTRUCTION REQUIRED BY HIS TRADE. OPENINGS WHERE PIPING, DUCTS, CONDUITS, ETC. PASS THROUGH WALLS, FLOORS, OR CEILINGS SHALL BE CLOSED OFF AND SEALED. ALL FIELD CONDITIONS AND DIMENSIONS SHOWN ON THE DRAWINGS SHALL BE VERIFIED PRIOR TO SUBMITTING BIDS & PRIOR TO COMMENCEMENT OF WORK (INCLUDING UNIT ORIENTATION). NO ALLOWANCE WILL BE MADE FOR NOT COMPLYING WITH THIS REQUIREMENT. MAKE FINAL CONNECTIONS TO OWNER'S EQUIPMENT. VERIFY H EXACT LOCATION F DIFFUSERS, LIGHTS, DEVICES ETC. PRIOR TO INSTALLATION. PETCO I THE E A LOCA 10 0 DIFFUSE L LL RESERVES THE RIGHT TO MAKE MINOR ADJUSTMENTS TO THE LOCATIONS AS SHOWN ON THE DRAWINGS PRIOR TO INSTALLATION WITHOUT ADDITIONAL COMPENSATION TO THE CONTRACTOR. 2) CONSTRUCTION PROPER FIRE PROTECTION MEASURES, SATISFACTORY TO THE LOCAL FIRE DEPARTMENT SHALL BE "TAKEN WHEN WELDING OR CUTTING WITH TORCHES OR ELECTRIC ARC. REMOVE ALL MATERIAL MADE OBSOLETE BY THIS WORK. ALL REMOVED EQUIPMENT, MATERIALS AND DEBRIS SHALL BE LEGALLY DISPOSED OF OFF OF SITE IN ACCORDANCE WITH ALL LOCAL, STATE AND FEDERAL CODES, RULES AND REGULATIONS. THERE SHALL BE NO RIGID CONTACT BETWEEN CONDUIT, PIPES, CEILING WIRES, AND DUCTWORK. STRUCTURAL SUPPORT AND FASTENING FOR ALL MECHANICAL AND ELECTRICAL AMENITIES FOR BIRD ROOM (DUCTWORK, SPRINKLER PIPING, CONDUIT, ETC.) SHALL BE FROM STRUCTURE ABOVE, NOT FROM BIRD ROOM STRUCTURE ITSELF. DOCUMENTATION DUCTWORK AND PIPING LAYOUTS ARE SCHEMATIC DIAGRAMS AND ARE INTENDED TO SHOW GENERAL ARRANGEMENT, SIZE AND CAPACITY AND DO NOT INDICATE WHICH DUCT OR PIPE IS ABOVE OR BELOW THE OTHER. ALL OFFSETS ARE NOT NECESSARILY SHOWN. CONTRACTOR SHALL ARRANGE AND T COORDINATE THE WORK, FURNISH NECESSARY OFFSETS AND FITTINGS TO AVOID CONFLICT WITH OTHER MECHANICAL AND ELECTRICAL SERVICES AND STRUCTURAL AND ARCHITECTURAL ELEMENTS WITHOUT ADDITIONAL COST TO THE OWNER. IF AREAS OF CONFLICT ARE ENCOUNTERED, THE ARCHITECT SHALL BE NOTIFIED AND CONTRACTOR'S RECOMMENDATIONS SHALL BE SUBMITTED TO THE ARCHITECT FOR APPROVAL BEFORE WORK HAS BEGUN. B. ELECTRICAL 1) ELECTRICAL WIRING, EQUIPMENT, GROUNDING & WIRING METHODS - REFER TO ELECTRICAL DRAWINGS AND PROJECT MANUAL. 2) EGRESS AND EXIT LIGHTING EGRESS LIGHTING SHALL BE PROVIDED BY SELF-CONTAINED BATTERY PACKS OR BATTERY BALLASTS INTEGRAL TO THE LIGHTING FIXTURES TO PROVIDE 1 FC (MINIMUM) THROUGHOUT PATHS OF EGRESS, WIRED TO THE NIGHT LIGHT CIRCUIT EXCEPT WHERE NOTED. OUTSIDE WEATHERPROOF EMERGENCY HEADS ARE TO BE LOCATED AT EACH EXIT DOOR. EXIT LIGHTS SHALL HAVE SELF-CONTAINED BATTERY PACKS, THE PLANS INDICATE THE MINIMUM NUMBER OF EMERGENCY LIGHTS AND EXIT SIGNS REQUIRED. THE CONTRACTOR SHALL PROVIDE ANY ADDITIONAL FIXTURES REQUIRED BY LOCAL AUTHORITIES HAVING JURISDICTION TO PROVIDE CODE REQUIRED MINIMUM LIGHT LEVEL AND DIRECTIONAL SIGNS. 3) WIRING DEVICES AND BRANCH CIRCUITS CIRCUITING - ALL CONDUCTORS SHALL BE COPPER UNLESS EXPLICITLY REQUIRED BY A MANUFACTURER'S INSTALLATION INSTRUCTION (IN WHICH CASE THE ENGINEER SHALL BE NOTIFIED) OR OTHERWISE EXPRESSLY PERMITTED OR INDICATED ELSEWHERE ON THE DRAWINGS OR IN THE PROJECT MANUAL. MINIMUM CONDUIT SIZE 3/4" UNLESS NOTED OTHERWISE. NO MORE THAN 3 CIRCUITS PER 3/4" CONDUIT. DERATE CONDUCTORS PER CODE WHEN GROUPING MULTIPLE CIRCUITS IN A SINGLE CONDUIT. MAXIMUM VOLTAGE DROP SHALL NOT EXCEED 2% FOR FEEDERS AND 3% FOR BRANCH CIRCUITS. DO NOT SHARE NEUTRALS FOR SINGLE PHASE CIRCUITS. DO NOT SHARE CONDUITS WITH ISOLATED GROUND CIRCUITS. NO MORE THAN 6 DUPLEX RECEPTACLES PER CIRCUIT. GROUNDING -- CONVENTIONAL EQUIPMENT SHALL BE GROUNDED IN ACCORDANCE WITH THE NEC. ISOLATED GROUNDING SHALL BE PROVIDED FOR CRITICAL LOADS INCLUDING, BUT NOT LIMITED TO, POINT OF SALE SYSTEM, COMPUTER CATALOGUING SYSTEM, AND OTHER SENSITIVE LOADS. REFER TO ELECTRICAL GENERAL NOTES. DEVICES - ALL DEVICES SHALL BE WHITE SPECIFICATION GRADE EXCEPT WHERE NOTED OTHERWISE. DEVICE PLATES SHALL BE AS FOLLOWS: (1) DEVICE PLATES ON WHITE FRP WALLS SHALL BE WHITE. (2) DEVICE PLATES FOR STOREFRONT SHOW CASE RECEPTACLES SHALL BE PAINTED TO MATCH WALL. 3 DEVICE PLATES OTHER THAN NOTED ABOVE SHALL BE BRUSHED STEEL. SOME RECEPTACLES ON CONTROLLED CIRCUITS ARE TO BE GRAY IN COLOR TO DIFFERENTIATE THEM FROM UNCONTROLLED CIRCUITS, DEVICE HEIGHTS -- SHALL BE AS FOLLOWS EXCEPT WHERE NOTED OTHERWISE WALL RECEPTACLES - 18" TO CENTER OF DEVICE COUNTER RECEPTACLES - 6" ABOVE COUNTER OR AS REQUIRED SWITCHES - 42" TO CENTER OF DEVICE 4) MISCELLANEOUS CONDUIT SYSTEMS FOR DATA SYSTEM SHALL BE 3/4" CONDUIT FOR UP TO SIX CAT5 CABLES AND/OR FOR THE EQUIVALENT OF A SINGLE GANG OUTLET BOX, PROVIDE CONDUIT BUSHINGS FOR ALL CONDUIT NIPPLES, SLEEVES AND RUNS FROM WALL BOXES TO ABOVE CEILING. THE ELECTRICAL SUBCONTRACTOR SHALL VERIFY ALL LOW VOLTAGE REQUIREMENTS WITH PETCO VENDORS. THE ELECTRICAL SUBCONTRACTOR SHALL PROVIDE CONDUIT WITH PULL STRINGS AS REQUIRED. NOTES FOR PROJECT: PETCO: SANFORD, FL 1. DEVIATIONS FROM PROTOTYPE A. GENERAL: 1. NO MAJOR ISSUES. B. PLUMBING: &Cl- �EXrEN�SIVEIRE PROTECTION CHANGES�MAIN�SAND SPRIN�KL66,�NO SPACE. 2. EXTENSIVE WATER, SANITARY AND VENT PIPING ROUTINGS PER NEW STORE LAYOUT. C. H VAC: 1. NO MAJOR ISSUES. RTU'S WILL HAVE ELECTRIC HEAT. "TRICAL:&ci 0A, 208/1= 2. UTILITIES A. NATURAL GAS: GAS IS NOT AVAILABLE AT SPACE. B. SEWER: NEW SANITARY PIPING DISTRIBUTION SYSTEM THROUGHOUT TENANT SPACE FOR ALL FIXTURES TO CONNNECT INTO BUILDING'S SANITARY SEWER SYSTEM WHERE INDICATED ON PLANS. C. WATER: NEW 2" TENANT DOMESTIC WATER SYSTEM THOUGHOUT TENANT SPACE FOR ALL FIXTURES TO CONNECT INTO LANDLORD PROVIDED 2" DOMESTIC WATER SYSTEM WHERE INDICATED ON DRAWINGS. D. FIRE SUPPRESSION: NEW TENANT SPRINKLER SERVICE DESIGN AND LAYOUT TO CONNECT INTO BUILDING'S SPRINKLER SYSTEM LOCATED WITHIN BUILDING, E. ELECTRIC SERVICE: MDP AND ALL POWER DISTRIBUTION EQUIPMENT, CONTRACTOR SHALL COORDINATE ACTIVITIES WITH THE LOCAL ELECTRIC UTILITY COMPANY AND LANDLORD REGARDING CONTRACTOR'S RESPONSIBILITIES FOR: A) CONDUIT AND WIRE FROM EXISTING PAD MOUNT TRANSFORMER TO MDP, B) TRENCHING AND BACKFILL FOR CONDUIT AND CONDUCTORS FROM UTILITY TRANSFORMER. C) CT, METER AND SERVICE ENTRANCE DISCONNECT SWITCH D) TELEPHONE CONDUIT AND WIRE FROM TELEPHONE PEDESTAL TO TELEPHONE TERMINAL BOARD. E) OTHER UTILITY AND SITE SPECIFIC REQUIREMENTS (SUCH AS TEMPORARY SERVICE) GENERAL SYMBOLS & ABBREVIATIONS IDENTIFIER C DESCRIPTION KEYNOTE SYMBOL KEYNOTE WITH LEADER O2 O3 MULTIPLE KEYNOTES APPLYING TO THE SAME ITEM w01 DETAIL IDENTIFIER P2.1 DETAIL # 01 DRAWING # P2.1 (DWG DETAIL IS LOCATED ON) 2 P2.1 SECTION IDENTIFIER SECTION # 01 DRAWING # P2.1 (DWG DETAIL IS LOCATED ON) 01 P2.1 ELEVATION IDENTIFIER ELEVATION # 01 DRAWING # P2.1 (DWG DETAIL IS LOCATED ON) A AMPS AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE BFG BELOW FINISHED GRADE BLDG BUILDING CLG CEILING CONTR CONTRACTOR DN DOWN DWG(S) DRAWING(S) EC ELECTRICAL CONTRACTOR EM EMERGENCY EMS ENERGY MANAGEMENT SYSTEM EQUIP EQUIPMENT ETR EXISTING TO REMAIN EWC ELECTRIC WATER COOLER EX EXISTING FLA FULL LOAD AMPS FS FLOW SWITCH GC GENERAL CONTRACTOR GWB GYPSUM WALL BOARD HP HORSEPOWER KVA KILO -VOLT AMPS MC MECHANICAL CONTRACTOR MCA MINIMUM CIRCUIT AMPS MFR MANUFACTURER MH MOUNTING HEIGHT MOD MOTOR OPERATED DAMPER NIC NOT IN CONTRACT NTS NOT TO SCALE OC ON CENTER PC PLUMBING CONTRACTOR PNLBD PANELBOARD PSI POUNDS PER SQUARE INCH PVC POLYVINYL CHLORIDE RPM REVOLUTIONS PER MINUTE SDD DUCT SMOKE DETECTOR SQ. FT. SQUARE FEET TYP TYPICAL S CLOSET MEN'S 109 ISO ROOM 117 WORK ROOK 118 CLOSET 120 BREAK RM 112 CLOSET 110 PRE -SALES KEY PLAN REF.: _ 1 1 1 l \ I - I PROFESSIONAL ENGINEER Duane S. Henderson FL PE# 46179 CAGE ROOF 105 TUB ROOM 106 GROOMING SALON 007 GROOMING RECEPTION 104 VESTIBULE 101 AQUARIUM AREA 115 OFFICE J m J J • m ILL 06 W > <w ®mz❑ - 0_j z W D 0 r� �✓ ®-- <F0J (n Z 0 LL W W U_jq WD Uz0O W Z O�U) CV -0 lip g z 0 0 a OU 00 Ww �u) DISTRIBUTION: DATE: 25% REVIEW 07/19/04 75% REVIEW 07/28/04 98% REVIEW 08/06/04 PERMIT 08/13/04 ADDENDUM #1 08/19/04 HEI JOB U PETCO P.M. JOB # 0450000526 DRAWN: CHECKED: ALR BJT DRAWING TITLE: PLUMBING, MECHANICAL & ELECTRICAL GENERAL INFORMATION PME1®1 ,ujy� I ESSIONAL ENGINEER :ane S. Henderson FL PE# — 46179 G U 'Vi1) O Q j� �\ U f U n U l\r/) w G U W • "4 LLJF- W rLLJ .- W W OUzU 1� now LOWrGWW "rnwoX — W r �% W ELX Z r7� U W W J r7 } Zrl) p CO U J ~ .. W W W I- ri W J J ■ m w m ®°LY_ OJ ILL Z � UCL Q (n �p0 ZULL WD ' 0 W W U_� w0 Uzzo w z oU)U) � o 0 Q a OC) ILU�o wW V L Q O� N DISTRIBUTION: DATE: 25% REVIEW 07/19/04 75% REVIEW 07/28/04 98% REVIEW 08/06/04 PERMIT 08/13/04 ADDENDUM #1 08/19/04 EIEI JOB ft PETCO P.M. JOB ft 0450000526 DRAWN: CHECKED: JMM DKS DRAWING 'ME - PLUMBING GENERAL INFORMATION AND SCHEDULES Pi .1 R I I I I I I I I I I I --- I C~ �� II!` 1 �M1.i Q2 e, 3. 3. •',. , t 1 /8" PER I RTU ELECTRIC ' FOOT SLOPE I 5TONS Cam_ ✓ -4„W ZOF L W -4 - - II / -4 „W !! COF T 1/8 PER \- INVERT �. FOOT SLOPE �` I �.. \ 2 j % I 97.38 o RTU I :.�........... r /r ELECTRIC `\ a- V) 10 TONS 2 I 0 �:1 2 .111 RTUELECT IC _.._ \ —�4 O TONS 1=1-/2„CW --T) =1/4"CW- 4"FW - 3/4"FW . 5-05 J 'S ! 4 � I I ! / PIPING INSTALLED AS I _ _ _ _ 1— _ _ _ _ � I PIPING INSTALLED AS MINIMUM REQUIRED I ;� - � r 1 � HIGH IN, �-�`------�--`--- �� HIGH IN ROOF INVERT 96.26' TO STRUCTURE AS POSSIBLE ,�" ., STRUC TUBE AS POSSIBLE (CONNECT INTO (SANITARY SYSTEM -- ! 12 12 I I 1 - 1 1 _ -- _ _ 1 - -- - - ---- - --- - - - - - --- -- - - __ -. - _ --_- - --- - ( �t- _ r 1 `� RTU ELECTRIC -- :.?G.1_j j �I 1 1 U TONS ELECTRIC L IJ 2"CW 3 10 TONS I � I `..�> PIPING INSTALLED AS FINISH FLOOR o ! ! I DELETED ENTIRE GAS PIPING HIGH II\ ROOF N ELEVATION 100.00' SYSTEM PER BUILDING THIS STRUCT RE. AS POSSIBLE =-»--- ALL STARTING INVERTS IS TOTALLY ELECTRIC � SHALL BEGIN AT 98.50' I PROJECT. I - NOTES REF.: GENERAL PLUMBING NOTES: 1. INSTALL WATER PIPING AS HIGH AS POSSIBLE TOWARD ROOF STRUCTURE. 2. INSTALL TRAP PRIMERS TO ALL FLOOR DRAINS TO MEET LOCAL CODES. 3. COORDINATE ALL UTILITY CONNECTIONS WITH LANDLORD AND UTILITY COMPANY. 4. INSTALL 4" SOIL AND WASTE PIPING AT I'll" FALL PER FOOT. INSTALL OTHER SOIL AND WASTE PIPING AT 1/4" FALL PER FOOT. SLOPE TOWARD POINTS OF CONNECTION. FIELD VERIFY FINISHED ' FLOOR ELEVATION AND INVERT ELEVATION OF EXISTING SOIL/SEWER PIPE FOR POINTS OF CONNECTION. 5. REFER TO MECHANICAL EQUIPMENT SHOP DRAWINGS FOR ! ORIENTATION OF UNITS FOR ACTUAL ROUGH -IN LOCATIONS. I I 1 II PLUMBING KEY NOTES: COORDINATE AND INSTALL NEW TENANTS 2 DOMESTIC WATER - O C NN CTION INTO TH 0 I DING'S 2 WATER SERVICE ENTRANCE. E E BU L OCOORDINATE AND INSTALL ROOFTOP UNIT CONDENSATE DRAIN WITH P- I j ( TRAP. EXTEND DRAIN LINE AWAY FROM UNIT WHERE CONDENSATE (I DRAINAGE FLOWS TO NEAREST ROOF DRAIN AND DOES NOT COLLECT IN WORKING AREA AROUND UNIT. -1i-- __ - I I I o3 NO PLUMBING PIPING SHALL BE ROUTED OVER ELECTRICAL PANELS AND/OR CLEAR SPACE. COORDINATE AND INSTALL A GENERAL PURPOSE HOSE BIBB TO THE o BOTTOM SIDE OF THE ROOF DECK NEXT TO THE ROOF HATCH WHERE _ I INDICATED ON DRAWINGS. HOSE BIBB SHALL BE SECURELY ATTACHED TO STRUCTURE TO AVOID HOSE BIBB FROM BEING PULLED FREE FROM THE ROOF STRUCTURE. HOSE BIBB TO BE INSTALLED CLOSE ENOUGH WII I TO ROOF HATCH THAT THE SERVICE PERSON CAN CONNECT A HOSE e I WITHOUT HAVING TO REACH OUT AWAY FROM LADDER. HOSE BIBB SHALL BE INSTALLED NOT TO INTERFERE WITH PASSAGE THROUGH ROOF HATCH OPENING IN ANYWAY. I O ONCE OUTSIDE THE BUILDING SPACE, COORDINATE AND CONNECT 1_----- - TENANT'S SANITARY SERVICE INTO LANDLORD'S SANITARY SERVICE AS SOON AS POSSIBLE. CONTRACTOR SHALL FIELD VERIFY THE EXACT LOCATION AND INVERT ELEVATION FOR TENANT'S SANITARY SERVICE CONNECTION POINT BEFORE ANY WORK BEGINS. IF FOUND THAT THE CONNECTION POINT CAN NOT BE MADE CONTRACTOR SHALL NO rIFY ARCHITECT AS SOON AS POSSIBLE FOR ISSUE TO BE RESOLVED NOT TO DELAY CONSTRUCTION SCHEDULE. ! 6O FIRE PROTECTION AND DOMESTIC WATER SERVICES PROVIDED BY - - — OTHERS. REFERENCE THE BUILDING SHELL DRAWINGS FOR THE j j I DOMESTIC WATER METER AND BACKFLOW DEVICE LOCATION AND INSTALLATION AND THE CONTINUATION OF SERVICE LINES. L i I �I I ! ! ) r , L_ - 1 I i I i I \ I I UNLESS NOTED. 1 3/4"CW r '' REVISED KEYNOTE NUMBERING I �t __- 2"CW � \ I PER DELETING GAS PIPING I � f J � SYSTEM ! HB2 4 gg FIRE _ 01 PROTECTION ENTRANCE I i PLUMBING FLOOR PLAN REF.: WOMEN'S 1oa MEN'S 109 ISO ROOM 117 WORK ROOK 11a CLOSET 120 BREAK RM 112 CLOSET 110 PRE -SALES 02 KEY PLAN 1 /8" = 1'-0" REF.: PROFESSIONAL ENGINEER DUCne S. Henderson FL PE# — 461%9 k(gCAGE ROOF 105 TUB ROOM 106 - GROOMING - SALON �-107 GROOMING RECEPTION 1 44 ! o VESTIBULE Ill 07 AQUARIUM AREA l_'-115 OFFICE 113 II-r� I� 01 NO SCALE J LY] J ❑¢p ILL ® ) Qw Om ❑ 0 e. -j LL cj� z LLJ 0 0 Q o z c) Li- �®— C�vw 0 W wo CL U) �- o = �� o 0 e 0 0a ad(KU Oci w(, W ILQ:o N Z DISTRIBUTION: DATE: 25% REVIEW 07/19/04 75% REVIEW 07/28/04 98% REVIEW 08/06/04 PERMIT 08/13/04 ADDENDUM #1 08/19/04 HEI JOB it PETCO P.M. JOB tt 0450000526 DRAWN: CHECKED: JMM DKS DRAWING MU: PLUMBING PLAN P2.1 U cu N IL 0 N 0 0 0 0 o_ 8 m a lu 3/4"H 3/4" C P4 3/4"CW 3/4"H W " 3/4CW r I f i _ I / V3: 1 "l-K PIPING INSTALLED AS HIGH IN ROOF STRUCTURE AS POSSIBLE U 1 /2°'CW GOWN IN I WALL 1� / N 1 \ 1 �- �- I 3/4"CW ` P 1 A• I :: 3 I V= ro I \ I — I 1/2" 1 /2' —1 /2"CW —1 /2"H W P6 3/, q"HW 1 I 11 U I I IPING INSTALLED Apl ri N IGH IN ROOF TRUCTURE AS POSSIBLE/ I _r'-)—TI T �. 1 "CW 1 "HW 3/4"FW— - �Fr1 0 z I sf / �'_ 9 I vl I� I 1 /2"CW 1 /2"H W 1l -r N\ k/ !L 1 1/ C W 1-11 2"HW +T - U I LARGE SCALE BACK OF HOUSE PLAN REF.: 02/P2.1 1/2"CW & HW DOWN IN WALL 1/2"CW & HW DOWN IN WALL /2"CW '2"H W — 4"FW — 05 1 /4" = 1'-0" ram`` -1=1- 2.•C W __..._. _ ._ 1 T 1 74" C W1`_--.__ 2 HW PIPING INSTALLED AS HIGH IN ROOF STRUCTURE AS POSSIBLE i I LARGE SCALE AQUARIUM AREA PLAN REF.: 02/P2.1 LARGE SCALE GROOMING AREA PLAN REF.: 02/P2.1 12 1/4" = V-0" 02 1/4" = 1'-0" NOTES REF.: GENERAL PLUMBING NOTES: 1. INSTALL WATER PIPING AS HIGH AS POSSIBLE AT/TO ROOF STRUCTURE. 2. ALL WATER PIPING UNDER SLAB SHALL BE TYPE 'K' COPPER IN ARMAFLEX. NO FITTINGS ARE PERMITTED UNDER THE SLAB. STUB UP FROM SLAB SHALL BE FITTED WITH 1/4 TURN BALL VALVE AT 12" AFF, WITH 3/4" FEMALE THREADS FOR CONNECTION BY PETCO VENDOR. 3. VERIFY ALL DIMENSIONS WITH THE PETCO VENDORS. 4. ALL DIMENSIONS ARE FROM THE INSIDE FACE OF UNFINISHED WALL. PLUMBING KEY NOTES: OSHORE -LINE GROOMING TUB WITH FAUCET, STRAINER, AND BACK - FLOW PREVENTER FURNISHED BY PETCO VENDOR. CONTRACTOR SHALL PROVIDE SUPPLY AND WASTE CONNECTIONS AS REQUIRED. CONTACT KAY STANDBRIDGE AT SHORE -LINE (877) 455-8190 X.2304 FOR ROUGH -IN INFORMATION. OBTAIN LATEST EQUIPMENT LITERATURE PRIOR TO ROUGH -IN. O2 FOREVER STAINLESS STEEL OVER -SIZE PET BATH WITH WALKING RAMP, FURNISHED BY PETCO, INSTALLED BY CONTRACTOR. RAMP ON RIGHT SIDE AND BRASS AND BRONZE WORKS MODEL B-0175 FAUCET BY VENDOR. CONTRACTOR SHALL PROVIDE SUPPLY AND WASTE CONNECTIONS AS REQUIRED. CONTACT MARK ARNDT AT FOREVER STAINLESS STEEL (402) 935-0771 FOR ROUGH -IN INFORMATION. OBTAIN LATEST EQUIPMENT LITERATURE PRIOR TO ROUGH -IN. O3 STUB OUT FACE OF WALL 1/2" CW AND HW ON 8" CENTERS FOR GROOMING TUB FAUCET 40" AFF. O4 STUB OUT FACE OF WALL 1/2" CW AND HW ON 8" CENTERS FOR SHORE -LINE FAUCET, 40" AFF. FAUCET AND BACK -FLOW PREVENTER PROVIDED BY PETco VENDOR, INSTALLED BY CONTRACTOR. NO DRAIN IS REQUIRED. CONTACT KAY STANDBRIDGE AT SHORE -LINE (877) 455-8190 X.2304 FOR ROUGH -IN INFORMATION. OBTAIN LATEST EQUIPMENT LITERATURE PRIOR TO ROUGH -IN. O5 WASHER AND DRYER FIXTURES FURNISHED BY PETCO, INSTALLED BY CONTRACTOR. q76 ;NOTUSED. O PLUMBING PIPING SHALL BE ROUTED OVER ELECTRICAL PANELS AND/OR CLEAR SPACE. O8 RISE 3/4" FILTERED WATER THROUGH 1/4 TURN BALL VALVE TO CEILING SPACE. O9 3/4" MIXED WATER TO FILTER. PROVIDE ALL NECESSARY ACCESSORIES. REFERENCE DETAIL 14/P4.1. 10 WATER FILTER FURNISHED AND INSTALLED BY MARINELAND RETAILER SYSTEMS (318) 747-6500. PROVIDE STUB OUTS FOR INLET AND OUTLET. SEE 14/P4.1. 11 ROUGH —IN FOR TOILET WATER SUPPLY SHALL BE AT LEAST 8" AFF TO AVOID CONFLICT WITH COVE BASE. 12 HOSPITALITY SINK FURNISHED BY PETCO VENDOR, INSTALLED BY CONTRACTOR. 13 3/4" FILTERED WATER FOR AQUARIUM MAINTENANCE. DROP TO 18" AFF IN FALSE COLUMN AND RUN ALONG TANK FIXTURE FRAMING ENSURING THAT PIPE IS SECURELY ATTACHED. STUB OUT 6" ABOVE FLOOR SINK AND PROVIDE 1/4 TURN VALVE AND 3/4" FEMALE ADAPTER. SEE DETAIL 20/P4.1 14 DROPS SHALL OCCUR IN FALSE COLUMN. LOCATE VALVES IN ACCESSIBLE LOCATION NOT BEHIND FIXTURES OR AQUARIUMS. COORDINATE AND INSTALL WATER PIPING DOWN IN FALSE COLUMN WITH ALL OTHER TRADES, PETCO AND AQUARIUM REPRESENTATIVES TO AVOID CONFLICTS BEFORE WORK BEGINS. PIPING WITHIN FALSE COLUMN HAS TO BE COORDINATED CLOSELY DUE TO LIMIT CLEARANCES. 15 1/2" HW AND CW FROM FALSE COLUMN. RUN HORIZONTAL AND RISE TO SINK FAUCET. WOMEN"S 02 108 c- MEWS e 3. 109 ISO ROOM 117 WORK ROOM 118 CLOSET 120 i BREAK RM 112 CLOSET 110 PRE -SALES 3 3. KEY PLAN REF.: CLOSET 114 Y - (qCAGE R001 -j--105 rr; I TUB ROOM k'I I GROOMING SALON --I�-107 GROOMING RECEPTION 104 VESTIBULE _ 101 AQUARIUM AREA 115 _.- OFFICE PROFESSIONAL ENGINEER Duane S. Henderson FL PE# — 46179 zw 0 t ow 0 O V w O O co r � d Lo E,Ld n w N Q G N W N i�ZO �oz" OV)UWOLJ V) fYO2��w P®1 F� iq/I W W O (Y 0 L< w � J_ Oa• w ') O zc �m �r W ❑ J t7] J p �U <� PYI J LL >v 06 Z 00 J W 0m ❑ ®_j U ®- QwDo (n z U u_ W:D WU EL W ~ - -O Ocncn N N 0 U oa IL!r wW q �z UISIRIBUTION: DATE: 25% REVIEW 07/19/04 76% REVIEW 07/28/04 98% REVIEW 08/06/04 PERMIT 08/13/04 ADDENDUM #1 08/19/04 HE[ JOB # PE'rC0 P.M. JOB # 0450000526 DRAWN: CHECKED: JMM DKS DRAWING nTLE WATER LARGE SCALE PLANS AND DETAILS TYPICAL FOR EACH ISLAND SINK FILTERED WATER HOT AND COLD WATER FAUCET BY FURNITURE VENDOR -�� (� SINK AND FAUCET BY -- -------FURNITURE FURNITURE VENDOR 1 /2" CW AND HW FROM CHASE 3/4" FILTERED WATER FROM CHASE " GAP L- 1 /4" TURN BALL VALVE VACUUM RELIEF VALVE, WILKINS #VR10 W ROOF rTHERMOMETER (TYPICAL) 1 1 /2" — 0 ? HW. TO FIXTURES CHECK VALVE r-- - 1/2" CW. INLET 1 GATE VALVE (TYPICAL) EXPANSION! TANK, WILKINS #WXTP II THIS c I HIGH EFFICIENCY GAS TUB AND FAUCET FURNISHED BY PETCO NSTALLED BY CONTRACTOR EXPOSED COPPER PIPING PROVIDED BY G.C. RUN ALONG WALL. TURN DOWN TO DISCHARGE INTO MESH BASKET. MAINTAIN CLEARANCE FOR BASKET REMOVAL. COOPER B-LINE MOUNTING BRACKET WITH CEILING FLANGE AND HINGED EXTENSION SPLIT PIPE CLAMP. MOUNT TO HORIZONTAL FRAME OF TUB. CONTRACTOR FABRICATED BASKET. STAINLESS STEEL WIRE MESH ON STAINLESS STEEL 5" DIAMETER X 5" DEEP, 20 GAUGE WIRE FRAME, TO BE HUNG FROM TUB TAIL PIECE. ALL SIDES SHALL BE 1/32" MESH. FABRICATE 20 GAUGE HANDLE TO ATTACH "f0 BASKET. SEE DETAIL 17/P4.1. Wall SWEAT A HOOK ONTO HORIZONTAL FRAME OF TUB. COPPER PIPE TO STABILIZE, AND ALLOW QUICK AND COOPER B-LINE MOUNTING BRACKET EASY REMOVAL O7v.,-1-1/2" WITH CEILING FLANGE AND HINGED EXTENSION SPLIT PIPE CLAMP. MOUNT HANDLE TO HORIZONTAL FRAME OF TUB. COPPER PIPING FROM GROOMING TUB. SEE 18/P4.1 LOOR 6" MIN LTYCONTRACTOR FABRICATED BASKET. 8 MAX2., STAINLESS STEEL WIRE MESH ON STAINLESS STEEL 5"DIAMETER X 5"DEEP 20 GAUGE WIRE FRAME TO I FIRED HOT WATER HEATER i I -'V—FLOOR SINK (FS1) WITH HINGED GRATE. FLOOR SINK FS1 BE HUNG FROM TUB TAIL PIECE. ALL INSTALL FLOOR SINK SUCH THAT HINGE I SIDES SHALL BE 1 /32 MESH. DRAIN TO FLOOR DRAIN/SINK FACES FAUCET END OF TUB. REMOVE SCREWS FABRICATE 20 GAUGE HANDLE TO FROM FLOOR SINK PRIOR TO INSTALLATION. ATTACH TO BASKET. UNION (TYPICAL) FLOOR NOTES: 1. TUB MAY BE MIRRORED FROM POSITION SHOWN. ;OLD WATER SUPPLY WITH SHUT-OFF /ALVE AND AUTOMATIC TRAP PRIMER, MADE #W-2400 OR JAY R.SMITH #2699 KITH VACUUM BREAKER. INSULATED TRAP AND WATER SUPPLY LINES, USE TRUEBRO HANDI LAV-GUARD ACCESS PANEL FOR 'TRAP PTIMER VALVE WITH AIR GAP FITTING WITH 1" AIR GAP. "LOOR DRAIN WITH TRAP PRIMER FITTING 2. FLOOR SINKS MUST BE SET TO FLOOR SLOPE. REFER "TO ARCHITECTURAL DRAWINGS. `- 1/2" 'K' (SOFT COPPER, NO JOINTS UNDER FLOOR SINK FS3 3. NO PENETRATIONS SHALL BE MADE THROUGH IMPERMEABLE SURFACES. FLOOR), SEE PIPE SPEC. COVER WITH ARMAFLEX. ISLAND PLUMBING DETAIL 20 WATER HEATER DETAIL 19 GROOMING TUB INTERCEPTOR DETAIL 18 GROOMING TUB PRE -STRAINER 17 TRAP PRIMER DETAIL 16 REF.: 12/P3.1, 12/P3.2, 02/P4.1 NO SCALE REF.: 02/P3.1, 02/P3.2 NO SCALE REF.: 12/P3.1, 12/P3.2, 02/P4.1 NO SCALE REF.: 18/P4.1 NO SCALE REF.: 02/P3.1 NO SCALE 3/4" CW 3/4" HW .3/4" FILTERED WATER PROVIDE ONLY WHEN PIPE MOUNTING BRACKET B-LINE #B3199-8 FROM WATER PRESSURE EXCEEDS PSI 8" ALL THREAD HEATER (P10) 1/4 TURN BALL VALVE WATER METER (CONFIRM SHUT-OFF VALV YP) B-LINE #B3199H 2" HINDGED CHECK VALVE (TYP.) (IN SUPPLY ROOM) EXACT LOCATION) EXTENSION SPLIT PIPE CLAMP. PRESSURE EF VALVE SET (TYPICAL) PRESSURE REGULATOR AT 85 P a a' REDUCED -PRESSURE ZONE THERMOMETER. I METER BACKFLOW PREVENTER COMBI riON PRESSURE 2" COPPER STANDPIPE INDUSTRIAL GLASS WEISS � 1-1/2" TO SYSTEM RE OAPSOIR(WATTS #223S)i P12 HAIR INTERCEPTOR EXPOSED WITH ONE (1) 90' INSTRUMENTS 2" WASTE AND VENT IN WASTE HOSE BOX. MODEL #9VS35. 3/4" MALE PRESSURE GAUGE WALL BEHIND CABINET. WASTE r- - - - - - I ADAPTER 0 - 200 PSI (TYP) SEE PLANS FOR ROUGH PERMANENTLY CAP WASTE 3/4" REDUCED PRESSUREI I T IN LOCATIONS. CONNECTION. ZONE BACK FLOW PREVENTER WATTS MODEL N1 3/4' FEMALE ADAPTER. 12" MIN. 1" PIPE, INSTALL TIGHT #909Q i-S I I / FROM WALL I I TO CABINET, DISCHARGE AIR GAP, WATTS MODEL ON FLOOR ON OPPOSITE 909AG-F, BENEATH BACK FLOW I I AIR GAP FITTING HEIGHT PER LOCAL # REQUIREMENTS SIDE OF CABINET FROM \� PREVENTER. ROUTE 2' DRAIN TO I WASHER STANDPIPE. FLOOR DRAIN/ SINK. I I NOTES: BYPASS L i jIt I DRYER 1�24 X60" CLEAR SPACE 1. PRESSURE REGULATOR AND METER BYPASS VALVE (NO Y CLOSED) WASHER FURNISHED BY PETCO'S VENDOR, 1-1/2" MAIN SHUT-OFF VALVE INSTALLED BY CONTRACTOR. FLOOR 40 ;4 60" AFF I I WATER FILTER, METER AND NOTE: ( I 2. MOUNT ALL EQUIPMENT ON SUPPLY ROOM (Typ•) I }/- PRESSURE REGULATOR BY WALL. MOUNTING HEIGHTS SHALL ALLOW VERIFY EXACT RE EMENTS FOR DOMESTIC WATER METER, BACKFLOW PETCO VENDOR PREVENTER AN RESSURE REGULATOR WITH WATER UTILITY COMPANY AND/OR REMOVE PORTION OF PAN TO ACCESSIBILITY ALL EQUIPMENT, AND MUNICIPAL A ORITY. PLASTIC 'HATER HEATER ACCOMMODATE PIPING. CAULK FURNISHED BY PETCO VENDOR ALLOW CONNECTION OF VENDOR PROVIDED PAN (2j"HIGH X 22" DIA.) AROUND PIPE TO SEAL. I EQUIPMENT. SEE 02/P3.1 WITH 1" PVC ADAPTER. ELEVATION VIEW WATER FILTER DETAIL 14 BAFLOW PREVENTER DETAIL 13 NOT USED 12 I L — — — — — — — J REF.: 02/P3.2 NO SCALE F.: 02/P2.1 NO SCALE REF.: NO SCALE NOT USED REF.: WASTE HOSE BOX DRYER VENT 8" LEFT OR WASHER STANDPIPE\n. RIGHT OF CENTERLINE 2" WASTE AND VENT IN 4" 8" aE 8„ WALL BEHIND CABINET. SEE PLANS IN LOCATIONSOR_R H11 II N P12 N ONLY ONE (1) 90' ELBOW ALLOWED 24" WIDE CABINET 24" 6„ I 27" 29.. Ij 1" PLAN VIEW NOTE: ARRANGEMENT MAY BE MIRRORED FROM POSITION SHOWN WASHER / DRYER UTILITY CONNECTIONS 06 REF.: 02/P3.1, 02/P3.1, 02/P4.1 I NO SCALE WOMEN'S 1oa MEN'S 109 ISO ROOM CLOSET 120 BREAK RM -SALES 02 KEY PLAN NO SCALE REF.: PROFESSIONAL ENGINEER Duane S. Henderson FL PE# — 46179 CLOSET r-gn ROOD TUB ROOM 106 GROOMING SALON a-107 ° GROOMING RECEPTION 104 VESTIBULE ° 101 AQUARIUM - AREA 115 OFFICE 113 N 01 NO SCALE 0 Z o r Ln L Qo rev o O L0 U V) f� W CT] <��CTiG \ NON O W. V) O W W V)pwOwV) Y � XMz � W I 0,wXl\ S o LL X J W p x t� w O UW { �1Jrq ZIp Q) CO J w w J m J s 0 2Ez ®LL 06 VJ J <W o m❑ Q� LL 27 � Z ®— <F-00 (n Z U LL. CL W:D I O W LL, wo 0zz0 L LL Z 0 OU)U) . ld a o CILL O J (-) ,)O 9L UO ww (ro mz mCA Ua) DIsrRIBUHON: DATE: 25% REVIEW 07/19/04 75% REVIEW 07/28/04 98% REVIEW 08/06/04 PERMIT 08/13/04 ADDENDUM #1 08/19/04 HEI JOB it PETCO P.M. J06 R 0450000526 DRAWN: CHECKED: JMM DKS DRAWING TITLE: PLUMBING RISER DIAGRAMS AND DETAILS P4. 1 i�j HVAC SCHEDULES DIFFUSER NECK SIZE_ SCHEDULE _ AIR VOLUME NECK SIZE UP 'TO 175 CFM 6% - -- 176 TO 275 CFM 8110 276 TO 380 CFM 10"o _ 381 TO 500 CFM 12"0 501 TO 700 CFM 14"0 701 TO 900 CFM 16"0 HVAC SCHEDULE _ SPACE SERVED _TREATMENT SEASON INDOOR DESIGN ('F DB) TEMP OUTDOOR AIR REQUIREMENTS RETAIL SUMMER 75 (OR AS REQUIRED BY CODE) 0.30 CFM/SQ FT WINTER 70 (OR AS REQUIRED BY CODE) 0.30 CFM/SQ FT PET AREAS SUMMER 75 (OR AS REQUIRED BY CODE) 1.00 CFM/SQ FT WINTER 70 OR AS REQUIRED BY CODE 1.00 CFM/SQ FT OFFICES SUMMER 75 (OR AS REQUIRED BY CODE) 20 CFM/PERSON _ WINTER 70 (OR AS REQUIRED BY CODE) 20 CFM/PERSON PRE -SALES SUMMER 75 OR AS REQUIRED BY CODE 0.15 CFM/SQ FT WINTER 70 OR AS REQUIRED BY CODE 0.15 CFM SQ FT REGISTER AND DIFFUSER SCHEDULE UNIT ID. MODEL DESCRIPTION NOTES CEILING DIFFUSER PERFORATED FACE SUPPLY AIR DIFFUSER WITH ADJUSTABLE CD1 1234 CURVED BLADES. LAY -IN. SIZE AS SCHEDULED ON PLAN 1 _ _NECK CEILING DIFFUSER PERFORATED FACE SUPPLY AIR DIFFUSER WITH ADJUSTABLE CD2 AL290 CURVED BLADES. SURFACE MOUNT. NECK SIZE AS SCHEDULED ON PLAN 1 CEILING RETURN AIR GRILLE PERFORATED FACE RETURN AIR GRILLE. NECK SIZE RG 1230 AS SCHEDULED ON PLAN. 1 CEILING RETURN AIR GRILLE PERFORATED FACE RETURN AIR GRILLE. NECK SIZE RG2 1276 AS SCHEDULED ON PLAN. 1 CEILING TRANSFER AIR GRILLE PERFORATED FACE EXHAUST AIR GRILLE. LAY -IN. T01 1230 NECK SIZE AS SCHEDULED ON PLAN. 1 CEILING TRANSFER AIR GRILLE PERFORATED FACE EXHAUST AIR GRILLE. SURFACE MOUNT. TG2_ 12_-P NECK SIZE AS SCHEDULED ON PLAN. 1 _ CEILING TRANSFER AIR GRILLE PERFORATED FACE EXHAUST AIR GRILLE. LAY -IN. T_G3 12.76 NECK SIZE AS SCHEDULED ON PLAN. 1- CEILING EXHAUST AIR GRILLE PERFORATED FACE EXHAUST AIR GRILLE. LAY -IN. EG1 1230 NECK SIZE AS SCHEDULED ON PLAN. 1 CEILING EXHAUST AIR GRILLE PERFORATED FACE EXHAUST AIR GRILLE. SURFACE MOUNT. E02 12-P NECK SIZE AS SCHEDULED ON PLAN. 1 CEILING FILTERED RELIEF AIR GRILLE, PERFORATED FACE FILTERED RETURN GRILLE FRG 12P-FF WITH 1" THICK FILTER. NECK SIZE AS SCHEDULED ON PLAN. 1 CEILING FILTERED EXHAUST" AIR GRILLE, PERFORATED FACE FILTERED EXHAUST GRILLE FEG 12P-F_F WITH 1" THICK FILTER_. NECK SIZE AS SCHEDULED ON PLAN. 1 _ _ 530 SERIES CONCENTRIC CEILING DIFFUSER. SIDE SUPPLY AIR DISCHARGE CENTER RETURN CCD 01-530-22 AIR DRAW. COMBINATION SUPPLY AND RETURN AIR DEVICE. 2 WALL TRANSFER AIR GRILLE HORIZONTAL BAR TYPE TRANSFER AIR GRILLE. WTG S90H NECK SIZE AS SCHEDULED ON PLAN. 1 NOTES: 1. SELECTIONS ARE BASED ON J&J REGISTER, ACCEPTABLE ALTERNATES TITUS, ANEMOSTAT, OR METALAIRE. 2. SELECTIONS ARE BASED ON ROOFTOP SYSTEMS INC. RSI , FURNISHED AS PART OF THE LENNOX RTU PACKAGE. ELECTRIC UNIT AND CEILING HEATER SCHEDULE UNIT ID. MANUFACTURER MODEL I BTUH MOUNTING CONTROL ELECTRIC DATA NOTES KW VOLTS I o AMPS CUH-1 BEF2K0 FFCH-T-548 10,200 RECESSED IN CEILING - ACCUSTAT 3.0 208 1 14.4 CUH-2 BERKO SRC-2024 5,12U RECESSED IN CEILING ACCUSTAT 1.5 1 208 1 1 1 7.2 1,3,5 NOTES: 1. ACCEPTABLE ALTERNATE INDEECO (CCI SERIES), OR Q-MARK (CDF SERIES) 2. PROVIDE FACTORY -INSTALLED 24 VOLT TRANSFORMER AND 24 VOLT HOLDING COIL CONTROL RELAY. ACCUSTAT MODEL #LH-1, LOW VOLTAGE, SINGLE STAGE, SET AT 757. REFER TO DETAIL 20/E1.3. PROVIDE PSG INDUSTRIES 3. COLOR SHALL BE WHITE. 4. PROVIDE FACTORY -INSTALLED ACCUSTAT MODEL #LMS-AH11. 24 VOLT TRANSFORMER AND 24 VOLT HOLDING COIL CONTROL RELAY. LOW VOLTAGE, SINGLE STAGE, SET AT 78-F COOLING, 74-F HEATING, PROVIDE REFER TO PSG INDUSTRIES DETAIL 20/E3.2 EXHAUST FAN SCHEDULE UNIT ID. MANUFACTURER MODEL TYPE DRIVE CFM EXT. S.P._ ACCESSORIES INTERLOCKED WITH SONES FAN RPM MOTOR WEIGHT LBS. IN WG HP VOLTS I EF-1 EF-2 EF-3 EF-4_ EF-5 EF-6 EF-7 GREENHECK GREENHECK GREENHECK GREENHECK GREENHECK GREENHECK GREENHECK GB-090-4 GB-070-4 GB-070-4 GB-080-4 G-60-D GB-070-4 GB-070-4 ROOF ROOF ROOF ROOF ROOF ROOF ROOF EXHAUST EXHAUST EXHAUST_ EXHAUST EXHAUST EXHAUST EXHAUSTBELT BELT BELT BELT BELT DIRECT BELT 715 180 250 170 100fO.25 14050 25050 0.625 0.50 0.50 0.50 1,3 1,3 1,3 1,3 1 2.3 1,3 1,3 EMS -- -- EMS -- -- -- 9.2 6.6 8.5 6.2 3.3 5.4 8.5 1429 1350 1556 1300 1473 1197 1556 1 1 1 1 1 1 1 4 4 4 6 6 4 4 120 120 120 120 120 120 120 1 1 1 1 1 1 1 1 1 1 30 1 30 30 30 14 30 30 ACCESSORIES: 1. FAN SHALL HAVE MANUFACTURER SUPPLIED ROOF CURB, BACKDRAFT DAMPER, AND ELECTRICAL DISCONNECT. 2. SOLID STATE SPEED CONTROLLER, SHIPPED LOOSE. 3. ACCEPTABLE ALTERNATE MANUFACTURERS ARE PENN, COOK OR BREIDERT. ROOFTOP UNIT SCHEDULE NOMINAL SUPPLY FAN DX COOLING COIL DATA HEAT ELECTRIC NOTES UNIT ID. MANUFACTURER MODEL CAP. CFM - E.S.P. _ CAPACITY (MBH OUTPUT COMP FLA FAN-- VOLT Hz MCA MOCP ��EER RTU-1 LENNOX LCA120H 10.0 4000 1010 0.8 128.0 90.8 22.5 17.3 3 208V/3/60 107 110 11.0 1,2,3,4,5 6 7,8 RTU-2 LENNOX LCA120H 10.0 4000/1010 0.8 128.0/90.8 22.5 17.3 3 208V 3 60 107 110 11.0 1 2 3,4,5,6,7,8 _ RTU-3 LENNOX LCA120H 10.0 4000 1010 0.8 128.090.8 22.5 17.3 3 208V 3 60 107 110 11.0 1 2 3 4 5 6 7 8 RTU-4 LENNOX LCA120f I 10.0 1010 0.8 128,0 90.8 22.5 17.3 3 208V/3/60 1208v73/6o 107 110 11.0 1 2,3,4,5,6,7 8 RTU-5 OX LENN LCA072H 6.0 ±ffl4O0Z715 0.8 74 59.2 15 19.9 2 75 80 10.5 1 2 3 4,5,6,7,9 NOTES: 1. INSTALL MANUFACTURER SUPPLIED ROOF CURB AND BURGLAR BARS. 2. UNIT SHALL BE PROVIDED WITH BAROMETRIC RELIEF DAMPERS, FILTER RACK, HAIL GUARD, AND FILTERS. 3. SMOKE DETECTORS AND SAMPLING TUBE TO BE FURNISHED BY LENNOX AND FIELD INSTALLED IN THE RETURN AIR STREAM BY THE HVAC CONTRACTOR. SMOKE DETECTOR REMOTE TEST/RESET STATION TO BE FURNISHED BY LENNOX AND FIELD INSTALLED IN THE LOCATION SHOWN ON THE DRAWINGS BY THE E.C. ALL SMOKE DETECTOR WIRING BY THE E.C. 4. UNIT SHALL BE VERTICAL DISCHARGE AND BELT DRIVE. 5. MODULATING ECONOMIZER WITH OUTDOOR AIR HOOD, ALL NECESSARY WIRING, DIFFERENTIAL ENTHALPY CONTROL, AND SENSORS SHALL BE FACTORY INSTALLED BY LENNOX. PACKAGED L SERIES UNITS SHALL HAVE FACTORY INSTALLED CONTROLS. INSTALLING CONTRACTOR SHALL INSTALL ALL NECESSARY WIRING AND CONTROLS TO INTERFACE WITH EMS SYSTEM. SEE HVAC AND ELECTRICAL GENERAL NOTES AS WELL AS NOTES ON PME1.1 AND SPECIFICATIONS IN THE PROJECT MANUAL. 6. UNIT SHALL HAVE FACTORY INSTALLED, FIELD WIRED WEATHER PROOF CONVENIENCE ELECTRICAL OUTLET WITH UNATTENDED WHILE -IN -USE COVER PLATE. 7. HVAC UNITS SHALL BE PURCHASED FROM LENNOX NATIONAL ACCOUNTS EXECUTIVE STEVE FRICKE. TELEPHONE: 972-497-6788 EXPECT 4-6 WEEKS DELIVERY TIME. 8. LENNOX SHALL FURNISH AND CONTRACTOR TO INSTALL DIFFUSER PACKAGE CONSISTING OF RETURN GRILLE AND FOUR WAY SUPPLY STEP DOWN DIFFUSER WITH PRIME COAT. CONTRACTOR TO FIELD PAINT PER SPECIFICATIONS, DIFFUSER PACKAGE TO BE LENNOX/RSI PRODUCT, 9. PROVIDE WITH LENNOX HUMIDITROL OPTION FOR L SERIES UNITS. blk HVAC GENERAL NOTES 1. PROVIDE FLEXIBLE CONNECTION ON ALL DUCT CONNECTIONS TO FANS AND OTHER EQUIPMENT. 2. BALANCE ALL AIR SYSTEMS AS PER SPECIFICATIONS. 3. DUCT SIZES SHOWN ARE CLEAR INSIDE DIMENSIONS. 4. PROVIDE TURNING VANES IN ALL SQUARE ELBOWS, UNLESS OTHERWISE NOTED, 5. PROVIDE VOLUME DAMPER ON EACH BRANCH TAKE OFF FROM DUCT MAIN AND ON EACH DIFFUSER TAKE OFF FROM BRANCH DUCT OR MAIN. 6. FLEXIBLE DUCT CONNECTIONS TO REGISTERS, DIFFUSERS, ETC. SHALL NOT EXCEED 6'-0" IN LENGTH. 7. ALL AIR MOVING DEVICES, INCLUDING BUT NOT LIMITED TO, AIR HANDLING UNITS, AIR CONDITIONING UNITS, AND UNIT VENTILATORS MUST COMPLY WITH AMCA STANDARD 210 AND ASHRAE STANDARD 62-1989. 8. CONTRACTOR SHALL COVER OPEN ENDED DUCTWORK WITH 1/2" X 1 /2" WOVEN WIRE MESH. 9. UNLESS OTHERWISE NOTED ON THE DRAWINGS, ALL MECHANICAL EQUIPMENT WITHIN THE CONTRACT LIMITS SHALL BE MOUNTED ON VIBRATION ISOLATORS TO PREVENT THE TRANSMISSION OF SOUND TO THE BUILDING STRUCTURE. VIBRATION ISOLATORS SHALL BE IN ACCORDANCE WITH THE SPECIFICATIONS AND ON ACTUAL WEIGHT DISTRIBUTION OF THE EQUIPMENT FURNISHED. DEFLECTIONS SHALL BE NOTED ON THE EQUIPMENT SHOP DRAWING SUBMITTALS. CONTRACTOR SHALL PROVIDE ALL SEISMIC AND HURRICANE RESISTANCE PROVISIONS REQUIRED BY LOCAL CODE, WHERE REQUIRED, PROVIDE DETAILS WITH CALCULATIONS SIGNED & SEALED BY A STRUCTURAL ENGINEER LICENSED IN THE STATE. 10. HVAC UNITS SHALL BE FURNISHED WITH A SMOKE DETECTOR WITH SAMPLING TUBE TO BE INSTALLED IN THE SUPPLY OR RETURN AIR STREAM AS REQUIRED BY LOCAL CODE. SMOKE DETECTOR INDICATOR LIGHTS SHALL BE VISIBLE FROM INSIDE THE BUILDING. HVAC CONTRACTOR SHALL INSTALL AND ELECTRICAL CONTRACTOR SHALL WIRE SMOKE DETECTORS. 11. HVAC CONTRACTOR SHALL BE RESPONSIBLE TO SUBMIT ONE SIGNED AND SEALED TESTING AND BALANCING REPORT TO THE REVIEWING AGENCY AND ONE SIGNED AND SEALED TESTING AND BALANCING REPORT TO THE LOCAL BUILDING OFFICIAL PRIOR TO PROJECT COMPLETION. 12. IPMENT SELECTIONS AREBA�SED:LTITU:DES ET L. LECTIONS FOROVER HALL BE CHECKE REQUIRED. 13. CONTRACTOR SHALL PROVIDE DECAL FOR EACH ROOFTOP HVAC UNIT, WITH MINIMUM 4" HIGH REFLECTIVE LETTERS, TO IDENTIFY EACH UNIT FOR MAINTENANCE PURPOSES. DECAL SHALL BE PLACED ON EACH UNIT ADJACENT TO THE UNIT POWER DISCONNECT SWITCH. 14. ROOFTOP HVAC UNITS SHALL BE SUPPLIED WITH COASTAL PACKAGE (COIL COATING, PAINTED RAILS, ETC.) WHEN SITE IS LOCATED WITHIN FIVE (5) MILES OF THE COAST. 15. INSTALLING CONTRACTOR SHALL PROVIDE ONE (1) SET OF FARR 30/30 2" DISPOSABLE PLEATED FILTERS IN EACH UNIT FOLLOWING SYSTEM STARTUP AND AFTER PROJECT COMPLETION. 16. CONTRACTOR SHALL STARTUP EQUIPMENT AND TEST FOR ALL FUNCTIONALITY (HEATING, COOLING, VENTILATION, ETC.) AND ALL STAGES AS A CONDITION OF FINAL ACCEPTANCE OF THE SYSTEMS. 17, FOR PROJECTS WHERE EITHER UNITS OTHER THAN LENNOX ARE FURNISHED (BY LANDLORD, FOR EXAMPLE) OR WHERE EXISTING UNITS ARE TO BE REUSED, HVAC CONTRACTOR SHALL FURNISH SMOKE DETECTOR SYSTEM SENSOR #DH100ACDCP WITH SAMPLING 'TUBE AND REMOTE TEST/RESET STATION RTS451KEY AND ELECTRICAL CONTRACTOR SHALL WIRE SAME. 18. AT THE CONTRACTOR'S DISCRETION, DIRECT DRIVE EXHAUST FANS MAY BE USED WHERE BELT DRIVE FANS ARE INDICATED, PROVIDED THAT 1) PERFORMANCE AND CHARACTERISTICS ARE SIMILAR, 2) DIRECT DRIVE FANS ARE PROVIDED WITH A SOLID STATE FAN SPEED CONTROLLER FOR FIELD ADJUSTMENT, AND 3) CHANGES AFFECTING OTHER CONTRACTORS ARE DONE SO AT NO ADDITIONAL COST TO PETCO. HVAC SYMBOLS IDENTIFIER L-� 1 C�T1T1T/ WOMEN'S 108 MEN'S 109 ISO ROOM 117 WORK ROOfv 118 CLOSET 120 BREAK RM 112 CLOSET 110 PRE -SALES DESCRIPTION NEW DUCTWORK EXISTING DUCTWORK TO REMAIN EXISTING DUCTWORK TO BE REMOVED INSULATED FLEXIBLE DUCT VOLUME DAMPER - - FD FIRE DAMPER AND ACCESS D007 - - FSD SMOKE DAMPER AND ACCESS DOOR - -- MD MOTOR OPERATED DAMPER XXX EQUIPMENT TYPE X EQUIPMENT NUMBER CFM, s CUBIC FEET PER MINUTE A ACCUSTAT OT THERMOSTAT H HUMIDISTAT 0 SENSOR FOR EMS SYSTEM ® CONNECT NEW TO EXISTING -� SUPPLY AIR FLOW EXHAUST AIR --•- UNDERCUT DOOR suu DUCT SMOKE DETECTOR 4 WAY CEILING DIFFUSER TYPE DIFFUSER TAG CFM CLOSET CAGE RO I TUB ROOM GROOMING SALON 107 GROOMING RECEPTION 10h VESTIBULE 101 AQUARIUM AREA OFFICE KEY PLAN 01 REF.: NO SCALE m J J m �. `�. LL 06 J <w O m �❑ .,� ®_j LL CL Z E WO Q (n OJ Z U u_ JCL � W W Ups W� O 0w Z Z O w 1L �: 2 Z • a 0 •� 06 ad00 ww �Z IL DISTRIBUTION: DATE: 25% REVIEW 07/19/04 75% REVIEW 07/28/04 98% REVIEW 08/06/04 PERMIT 08/13/04 ADDENDUM #1 08/19/04 HEI JOB # PErco P.M. JOB # 0450000526 JCC I KB DRAWING ME: MECHANICAL GENERAL INFORMATION AND SCHEDULES mi .1 NOTES PROFESSIONAL ENGINEER ` Duane S. Herlderson REF.: FL PE# — 46179 GENERAL HVAC NOTES: 1. REFER TO MECHANICAL SCHEDULES FOR APPLICATIONS OF ROOFTOP HVAC UNIT DISCHARGE PACKAGES. -- -- -- -- - - - - - 2. MAINTAIN MINIMUM 10 -0 BETWEEN OUTSIDE AIR INTAKES AND . .fj ANY EXHAUST OUTLET OR PLUMBING VENT. L / EG1 \ ((C 3. REFER TO SHEET E2.5 FOR LOCATION OF CONTROL DEVICES. 4. ALL DUCTWORK IN AREAS WITH SUSPENDED CEILINGS SHALL BE CONCEALED ABOVE CEILING. f 5. CONTRACTOR MAY AT HIS DISCRETION, USE ROUND DUCT OF CD1 -.-•_- 75 AREAS.LDUCT ISHALL LBElr*UI �SU LA fETD AS SPECIFIED. NCEALED MI(IROOF CD1 HVAC KEY NOTES: © I 1 ( ; 550 _ - I 1 I I Ol 14" ROUND DUCT UP TO EF#1 ON ROOF. I I 16-7 9I�J 1CD1 GRILLE WITH HINGED FRAME FOR INTEGRAL, CLEANABLE FILTER. 12" DN 12"0EXHAUST GRILLE ( i�` 5503 4" DIAMETER RIGID GALVANIZED DRYER VENT, IN WALL SPACE, IN CEILING (OPEN O2 THROUGH ROOF WITH VENT CAP. LOCATE VENT 8" LEFT OR TO PLENUM) FRO I 100 i ( 6 CENTERLINE OF DRYER 5" AFF USE 90' 4" CLOSE ELBOW ---- RIGHT AS REQUIRED TO AVOID DUCTWORK ABOVE CEILING OF E01 1 �.0--75- CD1 6 ---- ---- � 85 J 14"x14" WALL TRANSFER GRILLE - (WTG). MOUNT - 14x14 BOTTOM 13'-2" AFF. PLENUM SPACE CABINET UNIT HEATER � J. \/ 18x18�I , 12"� (....'.'.'.'.'....'. /\ ' '.'.'.'.'..... , ` O9 10" ROUND DUCT DOWN FROM EF ON ROOF, THROUGH ROOF 7.i' 1611- 50--------- OF BIRD ROOM AND TERMINATE IN PLENUM SPACE ABOVE BIRD ROOM CEILING. ...'................ i RTU 13 5 3. 15 I A3. \ (TYP) 180 % SECTION 2 _ II I I \ II BIRD ROOM SECTION VEIW 07 LARGE SCALE GROOMING PLAN 07 f0 i i REF.: 04/M3.1 1/4" REF.: 02/M2.1 1/4" = 1'-0" EG2. I i I I I I 07 CD1 I 1_ A3. 150 I TRANSFER GRILLE IN \` / \ CEILING. PROVIDES GRILL IN PLYWOOD �/ 2 \\ 5 10x10 DECK AND DUCTWORK / ( 10"x10" WALL TG1> AS REQUIRED. \' 3. 3. TRANSFER GRILLE/ \180 , 'TM-- (TYP) WOMEN'S (WTG). MOUNT i \\ (TYP) I '� 108 3 � 3BOTTOM 41145ET 5 13'-2" AFF. - MEWS CU- i.� � CAGE ROOM TG1 % �- \ 6 EF 18 109 '105EF \�6 3. ISO ROOM''�/_wti ii , /j TUB ROOM 02 i ii , / f 2 7 - \ `. _� ON ROOF WORK ROOM !x; I _ I .I _ %�' �; I I 106 or1 ROOF 9 18 �/ 5 /` 118 I, I �, I �,� % I 1 �/% -� GROOMING �O V -- 3. 120CLOSET 107 - ` C /0� i� / ❑ \FEG i \ �\ �%- \ I,� \_-� GROOMING ORIENT CUH SUCH BREAK RM RECEPTION 2 2 \` O � ��` // CLOSET � > l l � > 112 THAT DISCHARGE AIR \, \ DOES NOT DISCHARGE / O 07 \ \ \, '' 110 /' \ _ - �� I VESTIBULE DIRECTLY ON CAGES. 101 PRE -SALES 116 j I I AQUARIUM 115 ,� Ly OFFICE I i� 04 u 3. NtJy LARGE SCALE HVAC PLAN 05 LARGE SCALE BIRD ROOM PLAN 04 OPEN 03 LARGE SCALE HABITAT PLAN 02 KEY PLAN 01 REF.: 02/M2.1 1/4" = 1'4' REF.: 02/M2.1 NO SCALE REF.: N/A NO SCALE REF.: 02/M2.1 NO SCALE REF.: NO SCALE I i 4. 31 TRANSITION FROM DRYER VENT TO VENT DUCT IN WALL. INSTALL PER APPLIANCE MANUFACTURERS INSTRUCTIONS. USE fK\ E - C. - - __ -.__ 1 STRAIGHTEST DUCT RUNS POSSIBLE TO OUTSIDE. \ FRG 8. / % 4 NOT USED �� / 550 — — I �! 16x16 O CL O5 8" SPIRAL FROM ROOF EXHAUST FAN TO BELOW TOP OF PLASTIC TUBING OF ANIMAL HABITAT FIXTURE. WHERE REQUIRED (TYP) 15 __ TO AVOID CONFLICT, PROVIDE MINIMAL OFFSET IN DUCT JUST 12x12 BELOW BAR JOIST. RETURN TO SITE AFTER HABITAT IS INSTALLED AND PROVIDE 4" FLEXIBLE EXHAUST DUCT DOWN CD1 hup I PREFABRICATED PLASTIC TUBING TO AIR DISTRIBUTION SPHERE AND AIR DISTRIBUTION BOX. TUBING AND SPHERE FURNISHED BY 400 �� j PETCO VENDOR. AIR DISTRIBUTION BOX BY MECHANICAL CONTRACTOR. MECHANICAL CONTRACTOR TO COORDINATE INSTALLATION WITH PETCO VENDOR. SEE DETAIL 02/M3.2. 10 "-______ ------ - I--- O6 4" EXHAUST FROM AIR DISTRIBUTION BOX IN PLASTIC AIR \ I I FEG DISTRIBUTION SPHERE TO HABITAT INSIDE PLASTIC TUBING. — — I 750 I TYPICAL FOR ALL FOUR (4) HABITATS. TUBING FURNISHED BY �- C TGl n ,O 'ON -ROOF--s ( PETCO VENDOR. MECHANICAL CONTRACTOR TO COORDINATE 300 ip EG1 I 18 SECTION 1 I \, EF INSTALLATION WITH PETCO VENDOR. USE EQUIVALENT LENGTH I I DUCT IN ALL LEGS OF HABITAT FOR INHERENT BALANCE OF AIR - 250 I EF 3. CD1 � _ � 1 1 18 SYSTEM. 7 ON ROOF I 400 3 — EG2 I I �` ----- O7 COORDINATE THE LOCATION OF THE EXHAUST DUCT WITH THE PI iO50 10"0 y- OWNER'S FURNISHINGS AND OTHER TRADES. REFER TO � J_J I TRANSFER DUCT FROM REFER TO ARCHITECTURAL I I I 16(TYP)ARCHITECTURAL PLANS FOR DESIGNATED, LIMITED AREA FOR I PLYWOOD DECK TO I II ------,-•---- ---I �------� I CEILING GRILLE PLANS FOR FRAMING AND I � � � _ ®� I I 3. �� EXHAUST DUCT AND OTHER TRADES' WORK. � MATERIAL SPECIFICATIONS ...... I I I I \ ..... O8 10" ROUND DUCT UP TO EF ON ROOF. _ I CI i I I 12xl2 I I EG1 150 ( EF 3. 1 3 ON ROOF o I I CD1 PLENUM SPACE LIGHT FIXTURE J Ia J e U ca z J ® LL 06 zu � W 0 mho 0 ®a LL. Q 0� z E o 0 U �- U) W Z U LL O U W 0 W� 0zz0w wo CJ') ?� � z O�U) • • 3 z no o= �a U ad o0 =w w �o cL m� DISTRIBUNON: DATE: 25% REVIEW 07/19/04 75% REVIEW 07/28/04 98% REVIEW 08/06/04 PERMIT 08/13/04 ADDENDUM #1 08/19/04 FIE[ JOB # PETCO P.M. JOB it 0450000526 DRAWN: CFIECKED: JCC KB DRAWNG TITLE: MECHANICAL LARGE SCALE PLANS AND DETAILS M3.1 N TJ a 0 A a ca U 6" SPIRAL STRAIGHT UP TO EXHAUST FAN - \ EXHAUST BOX. SEE DETAIL \ HABITAT INTAKE PORT (TYP.) AT LEAST ONE PORT PER UNIT REMAINS EXPOSED O�: ENDCAP (NO EXHAU CONNECTION) TYPICAL BAC 0-BACK UNITS OF PTILE HABITATS (PROVID BY PETCO) IONAL THIRD UNIT. SEE FIXTURE PLAN 4" WIDE SHEET METAL STRAP - SECURE WIRE TO STRUCTURE ABOVE - 45' RIGID ROUND ELBOW---_� a ROUND NECK DIFFUSER OR GRILLE -� +/-47" I I 8 -\NN` ` �` I ►'--'- — OFFSET JUST BELOW BAR JOIST (ONLY 6"� COLLAF IF NECESSARY TO AVOID STRUCTUREghting) OPEN A `.�_� or li (TY CENTERED 4"0 METALLIC FLEX, NO KINKS 8 (IF REQUIRED) �_ I 8" GASKET AROUND BOTTOM OF ' OPENINGS AND FASTEN BOX T 4"0 COLLAR IF �`\ THE TOP OF THE HABITAT. �`\ REQUIRED FOR `\� p`� �N\ �`\ HABITAT UNIT 'I `\`\\ \�`', �y'� I 52" ' ' I SOLID BOTTOM I LOCATION OF 0 COLLAR ON I I TOP OF H AT (TYP. FOR 2) EXHAUST BOX DETAIL I i USE 22 GAUGE SHEET METAL I I R IL E HABITAT DETAIL F.: 03/M3.1 ACOUSTICAL FLEX DUCT 6'-0" MAXIMUM LENGTH VOLUME DAMPER PRE-FAB SPIRAL CEILING ROUND DUCT — DIFFUSER CONNECTION DETAIL REF.: 3/8" SQUARE ROD GASKET LA_ VENTLOCK NO. 641 REGULATOR LOCKNUT PLAN SPUN ALUMINUM ROOF EXHAUSTER PREFABRICATED ROOF CURB — MANUAL VOLUME SECURE TO STRUCTURE ABOVE F\ DAMPER AS RECOMMENDED BY SMACNA. CURB MOUNTED EXHAUS"f FAN R"X W.(4"MIN.) BRANCH DUCT -SEE ROOFING FLOOR PLANS FOR I I GALVANIZED IRON STRAP TAPERED SIZE AND ROUTING ALUMINUM S"iRAP, "TURN UNDER TAP -IN CONICAL SHAPED j I \N DUCT MINIMUM 1". RIVET OR FITTING SPIN -IN TYPE FITTING. I I BOLT TO UNDERSIDE OF DUCT. USE THIS FITTING PLENUM OR DUCT MODULAR METAL FLEX SM-22 WHERE SPIN -IN SHEET METAL SCREW, RIVET OR FITTING IS LARGER BOLT TO BO"rH SIDES OF DUCT. THAN DUCT OR LID PLENUM WHERE APPLICABLE, A) SUPPORT FROM UNISTRUT SPANNING TOP CHORD OF BAR JOISTS. B) USE DUCT STRAPS WITH BOLT CLAMP TO SUPPORT ROUND �-TRANSITION II \ STEEL FRAME (BY PLENUM OR DUCTS `\ DUCTWORK. STRUCTURAL STEEL (AS REQUIRED) HEIGHT MINUS 2" `N CONTRACTOR) RECTANGULAR TO ROUND \\` LOW -LOSS FITTING ATTACH WITH SHEETMETAL BRANCH DUCT -SEE FOR BRACING ANGLES SEE NOTES. NOTES: SCREWS AND SEAL WITH MEDIUM FLOOR PLANS FOR 1. SECURE EXHAUST FAN UNIT TO CURB PRESSURE DUCT SEALER SIZE AND ROUTING NUT AND WASHER AT END OF ROD. 19 ROOF -TOP EXHAUST FAN DETAIL 18 BRANCH DUCT TAKEOFF DETAIL 17 DUCT HANGER DETAILS 16 NO SCALE REF.: NO SCALE REF.: 02/M2.1 NO SCALE REF.: NO SCALE 1 � � DISCONNECT DISCONNECT- ROOF TOP UNIT ROOF TOP UNIT (TYPICAL) (TYP.) OOF CURB, SEE ROOF CURB, SEE H.V. A.C. H.V.A.C. RCH'L DRAWINGS 11 AFZCH L DRAWINGS 11 Unit 3 2 Unit M3.2 EXTEND MIN. 3'-0" PAST 14" HIGH CURB 0 1 F 14" HIGH CURB R OF PT DOWNHILL SIDE OF UNIT CONDENSATE 4" MINIMUM 4" MINIMUM _ VENT DRAIN PAN \Z FLEXIBLE DUCT RIGID DUCT WITH 1" THICK 4"MIN. CONNECTIONS (TYP.) ROOF JOIST - VERIFY SIZE DUCT LINER INSULATION 4AI AND LOCATION CANVAS FLEXIBLE F---2" MIN. CONNECTOR (TYP.) I UNION STRUCTURAL SHI D CANVAS FLEXIBLE PLENUM CONNECTOR (TYP.) 1 COPPER TYPE 'B' GAS RECTANGULAR DUCT WITH 1" 71WHERE INDICATED ON 5 (PVC WHERE PERMITTED) FLOOR PLAN FO I S THICK DUCT LINER INSULATION DUCT (TYP.) SEE BRANCH PLANS, DUCT RUNOUT WITH TRANSITION TO DUCT DUCT TAKE -OFF DETAIL VOLUME EXTRACTOR ON OPENING ON DIFFUSER 7 NOTES FOR DETAILS 12 Ec 13: SUPPLY CONNECTION CLEAN OUT AS SHOWN ON FLO PLAN 1. SECURE HVAC UNITS TO CURB, REF DETAIL 6/M3.2. CONCENTRIC DIFFUSER 2. SEE ARCHITECTURAL PLANS FOR SECURING CURB TO ROOF AND ROOFING AT SEE M2.1 FOR MOUNTING NOTES: CURB DETAIL. HEIGHT INFORMATION 1. EXTERIOR FLUE AND ACCESSORIES, ABOVE THE ROOF, SHALL BE PAINTE S SPECIFIED. COLOR AS SELECTED BY ARCHITECT. 3. WHERE REQUIRED BY LOCAL CODE, PROVIDE PIPED CONDENSATE TO 2. ALL IMUM METAL GAUGES TO MEET MODEL CODE REQUIREMENTS. APPROVED RECEPTOR, USING COPPER OR UV RESISTANT PVC, OR PAINT PER SPECIFICATIONS. 15 F1 HROUGH ROOF DETAIL 14 RTU PACKAGE HVAC UNIT DETAIL 13 RTU PACKAGE HVAC UNIT DETAIL NO SCALE F.: 02/M2.1 NO SCALE REF.: 02/M2.1 NO SCALE REF.: 02/M2.1 VENTLOCK NO. 609 END BEARING AJ GASKET INDICATING HANDLE 1/4" DIAMETER SET SCREW SPOTWELD �1"X1/8" GALVANIZED BLADE �✓ �- 16 GAUGE GALVANIZED BLADE 3/8" SQUARE ROD 1/4" LESS THAN DUCT 0 SECTION A -A CLOSURE COLLAR STORM COLLAR CONTINUOUSLY WELDED TO STAC INSULATED AND VENTILATED THIMBLE " TYP: 6" SUPPORT THE AIR DISTRIBUTION BOX WITH APPROPRIATE GAUGE CABLE/WIRE TO SUSPEND THE BOX WITHIN THE SPHERE. 8"0 X 2" HIGH COLLAR -� 4"0 X 2" HIGH COLLAR, TYP. 135' 3'-0" i � I co MINIMIZE STATIC PRESSURE LOSS IN DUCT BY LIMITING THE AMOUNT OF TURNS Al\ KINKS INSIDE THE SPHERE. 4" EXHAUST DUCT FURNISHED AND INSTALLED BY CONTRACTOR, INSIDE PLASTIC TUBE FURNISHED BY I VENDOR, TO ANIMAL HABITATS. PROVIDE VOLUME DAMPER. SEE DETAIL 05/M3.2. TYPICAL FOR ALL FC HABITATS. EXHAUST 35 CFM FROM EACH HABITAT. A< APPROXIMATELY 8'AFF 12 ! CONDENSATE TRAP DETAIL NO SCALE SPIRAL EXHAUST DUCT FURNISHED AND TALLIED BY CONTRACTOR, INSIDE PLASTIC IE PROVIDED BY PETCO VENDOR, CONNECTED DUCT ABOVE IN JOIST SPACE TO ROOF iAUST FAN. PROVIDE SQUARE -TO -ROUND ;T TRANSITION. �STIC AIR DISTRIBUTION SPHERE, 2 HALVES, )VIDED BY PETCO VENDOR. FABRICATED AIR DISTRIBUTION BOX. 3RICATED AND INSTALLED BY MECHANICAL (TRACTOR. BOX SHALL BE EXHAUSTED TO 8" �T ON THE TOP FROM HABITATS ON ALL FOUR ES. SEE DETAIL 04/M3.2. PLASTIC AIR DISTRIBUTION SPHERE, 2 HALVES, PROVIDED BY PETCO VENDOR. NOTE: 1. USE 20 GAUGE SHEET METAL. FINISHED FLOOR ROUND VOLUME DAMPER DETAIL 05 AIR DISTRIBUTION BOX DETAIL 04 AIR DISTRIBUTION SPHERE DETAIL REF.:02/M3.2 NONE REF.:02/M3.2 NONE REF.:02/M3.1 11 NO SCALE "-FOREAT O STRUCT N f URAL SHEET REQUIREMENTS ATTACHMENT BRACKET FURNISHED BY HVAC UNIT MANUFACTURER, INSTALLED BY CONTRACTOR. INSTALL ONE BRACKET PER SIDE OF UNIT OR AS RECOMMENDED BY MANUFACTURER. RTU HOLD DOWN BRACKET 06 REF.: 02/M2.1 NO SCALE WOMEN'S CLOSET MEWS------ --- 109----_.u_- - ---- ���- --- i CAGE ROOt ISO ROOM -f I I I 105 -~\ 117 T TUB ROOM WORK ROOM - _ l 106 118 I L"i I r' --4 GROOMING SALONCLOSET 120 BREAK RM - - fi' r.. 0 GROOMING RECEPTION 112 1/ If \ 104 CLOSET -� Il ' - -I r� VESTIBULE 101 PRE -SALES -1 - 02 KEY PLAN NONE REF.: AQUARIUM AREA 115 • 1 � J � ( 1 OFFICE 113 l � - -�- - -- - - ---r-s r=,l- N 01 NO SCALE 1 I m J rr ��. m LL 06 Z Uj �W O mho 0_j U QUJ00 U)zc)LL a, r W W - W:D ' 0 z z O ki. �/� ) I—' = O W Q 1— (1) W •S Va Ir oU_ • 7 O< �U 00 =w W it Cl �Z �a DISTRIBUTION: DATE: 25% REVIEW 07/19/04 75% REVIEW 07/28/04 98% REVIEW 08/06/04 PERMIT 08/13/04 ADDENDUM #1 08/19/04 HEI JOB 11 PETCO P.M. JOB 11 0450000526 DRAWN: CHECKED: JCC KB DRAWING TITLE: MECHANICAL DETAILS M3.2 LCk LCk LCk LCk LCk LCk LCf ,LCk LCK , LCk E LCt LCf E E E E E E E E E E E E E E E E E E E PANELBOARD: A FAULT CURRENT: 61,370A EQUIPMENT GROUND BUS BUS AMPS: 225A AIC RATING: 65,000A SERIES RATED MAIN SIZE/TYPE: MLO SERVES: PETCO VOLTS/PHASE: 208Y/12OV, 3PH, 4W MOUNTING: FACTORY INSTALLED SECTIONS : 1 LOCATION: PRE -SALES, ROOM :118 CK-T NO. DESCRIPTION VOLTAMPS PHASE WIRE NO. BKR AMP P P BKR AMP WIRE NO. VOLTAMPS PHASE DESCRIPTION CKT N0. A B C A B C__] 1 3 PANELBOARD CR 1,650 !,/% _ 800 %I; j;'!- %/;;/j ; 10 30 2 _ 1 20 %% /' //// / ////i SPARE 2 _ 1 20 12 j, /,•;% 500 /; BIRD RECEPT (EMP) 4 5 CHECK COUNTER RECEPT 360 10 20 1 1 20 12 /;; // //; 250 DOCK LIGHT (EMP 6 7 CHECK COUNTER RECEPT 360 //; /;'/%%i,'; 10 20 1 1 20 10 720 ', //, / 7/7/ WINDOW RECEPT 8 9 _ 11 CHECK COUNTER RECEPT CHECK COUNTER RECEPT j;'/,/,T j/% ;% / 360 10 10 20 20 1 1 1 _ 1 20 20 10 10 ;/�� //,/ 1 920 , / / ; 1,920 END CAP DISPLAY (CUST) END CAP DISPLAY (CUST) 10 12 13 SPARE '; /; ;;'/',;;% 20 1 1 20 10 1,920 ///,/; / / j; END CAP DISPLAY (CUST) 14 15 AVIARY TRANSMITTER RECEP"f ///'/; 180 '%f,/j �; 12 20 1 1 20 10 ,//j;j� 1,920 ,/; END CAP DISPLAY (CUST) 16 17 OFFICE RECEPT i /%; /% /; 360 12 20 1 1 20 10 /;%//; //% / 1,920 END CAP DISPLAY (CUST) 18 19 OFFICE RECEPT 360 //''/j //i:;% 12 20 1 1 20 /, , ; /; ,, ,SPARE 20 21 PRE -SALES RECEPT r �;% //; - 360 % /% /; 12 20 1 1 20 //%% ; / //,- SPARE 22 23 25 FIRE ALARM SPARE ; j%, ji '/ ;!%,; ; , / / 300 % j ! , 12 20 20 1 1 1 1 20 20 12 12 500 /, /i ; 200 ;; QUICK TAG (EMP) SODA COOLER 24 26 27 SOUND SYSTEM / �? 200 12 20 1 1 20 12�'; / /; 100 // / ; DOOR BUZZER 28 29 31 EMS-1'%/i; EMS-2 200 ' j j/ 200 12 12 20 20 1 1 1 1 20 20 12 12 l/,i 720 / ,/,% ; %/; 300 //////, EWC (EMP) SALES/MISC RECEPT 30 32 33 TURTLE DISPLAY ;-;;!!// 360 ;;/j j,; 12 20 1 1 20 12 '/,ji%,I 360 /,; KEET PETTER 34 35 MAIN TELCO TERM BOARD ; / //, ; ;- , /; 500 12 20 1 1 20 /; SPARE 36 37 SECURITY SYSTEM 200 / //;; ;%j ';!; 12 20 1 1 20 12 1,356 ', ,/ TANK DISPLAY 38 39 K01 DISPLAY 36012 20 1 1 20 12 1,356 /% //,; TANK DISPLAY 40 41 SPACE ONLY , //%%I / /i SPACE ONLY 42 SUBTOTAL 1 2,770 1 2,620 1 2,080 5,216 1 6,156 1 4,590 SUBTOTAL TOTAL PHASE A - VA AMPS 7,986 LOAD CONN. VA DF LOAD CONN. VA DF GF-GND FAULT CKT INTERRUPT E - EMS CONTROLLED CIRCUIT LCK - LOCKABLE TAB 67 COOLING HEATING -- J- - 1. 00 1.00 REFRIGERATION 1.00 TOTAL�PHASE B - VA AMPS TOTAL PHASE C - VA AMPS 8,776 DISPLAY CASE 1.25 73 LIGHTING _ GEN. R_ECEPTS_ _ 250 -_ _ 1.25 KITCHEN v--�_ 1.00 6,670 _ ITOTAL DEMAND VA 1 24,404 AMPS 68 56 MOTORS SUPP. HEAT _20,732-�1.01.5 - _ 1.00_ 1.00 TOTAL PANEL - VA 2,3 432 AMPS 65 _ MISC EQUIP _ _- _ 0.50 PANELBOARD: B FAULT CURRENT: 61,370A EQUIPMENT GROUND BUS BUS AMPS: 225A AIC RATING: 65,000A SERIES RATED MAIN SIZE/TYPE: MLO SERVES: PETCO VOLTS/PHASE: 208Y/12OV, 3PH, 4W MOUNTING: FACTORY INSTALLED SECTIONS : 1 LOCATION: PRE -SALES AREA, ROOM :118 CKT NO, DESCRIPTION VOLTAMPS PHASE WIRE NO. BKR AMP P P BKR AMP WIRE N0. VOLTAMPS PHASE DESCRIPTION CKT N0. A B C A B C 1 SHUNT TRIP POWER j/i 12 20 1 1 20 12 100 ;%;!'jjj'%!//,j SMOKE DETECTOR 2 3 EF-1 (EMP) fi ; 696 ; ;;, j;!� 12 15 1 3 20 ;%; /,// SPARE 4 5 EF-2 // j/; :/� ; 696 12 15 1 , ////; //; !/- 6 7 EF-3 528 77, / '12 15 1 / 8 9 EF-4 (EMP) 528 ' , / // 12 15 1 _ 2 _ 15 12 ' / /, ; 750 /; /; C U H - 2 10 11 EF-5 528 12 15 1 ; , /,.'j ///,� /; 750 12 13 EF-6 696 ///;; i; - ! ; 12 15 1 1 20 10 1,200 EXTERIOR SIGNS 14 15 EF-7/%/, 528 j' ,/ i 12 20 1 1 20 /' /; ///; SPARE SIGN 16 17 SPARE j% /'; 'i ; ;/; 20 1 1 20 % % //; %; jj' ; SPARE (SIGN) 18 19 RTU RECEPT 720 /,ij;; // // 12 20 1 2 20 12 1,500 CUH-1 20 22 21 SPARE 20 1 /%/%i 1,500 23 SPACE ONLY !i, j;j; .// /; _ 1 _ 1 20 SPARE 24 25 SPACE ONLY /� j;/ ,/; 1 1 20 10 1,320 //, jj %//; AQUARIUM LIGHTS 26 27 SPACE ONLY :; 'j'" j/%/,/; 1 1 20 10 / /// 1,320 / //; AQUARIUM LIGHTS 28 29 AUTOMATIC DOOR 1,200 12 20 1 1 20 10 1,320 AQUARIUM LIGHTS 30 31 AUTOMATIC DOOR 1,200 ,/,//%/j / 12 20 1 1 20 10 1,320 / / ' //// / AQUARIUM LIGHTS 32 33 AUTOMATIC DOOR !// ` / , /j,/ 1,200 '^ ; j/;/�/ 12 20 1 1 ; ;' /jj; SPACE ONLY 34 _ 35 SMALL ANIMAL POWER (EMP) j // /. ,%//%; 660 '12 20 1 1 j%%; 'f ; ; SPACE ONLY 36 37 SMALL ANIMAL POWER (EMP) 12 20 1 1 ; //j/; , / ; SPACE ONLY 38 39 SMALL ANIMAL POWER (EMP) 660 ;j,i; 12 20 1 1 ,,i // ; /; SPACE ONLY 40 41 SMALL ANIMAL POWER EMP '/,//%%/ _ /; / %; 660 12 20 1 1 //i'/// 77 /i SPACE ONLY 42 SUBTOTAL 1 3,804 1 3,612 1 3,744 1 5,440 1 3,570 1 2,070 SUBTOTAL TOTAL PHASE A - VA AMPS TOTAL PHASE B - VA 9,244 LOAD CONN. VA DF LOAD CONN. VA DF E - EMS CONTROLLED CIRCUIT LCK - LOCKABLE TAB 77 COOLING 1.00 1.00 REFRIGERATION 1.00 7,182 HEATING__._______ - _ CASE - _ 1.25 AMPS TOTAL PHASE C - VA AMPS TOTAL PANEL - VA AMPS 60 LIGHTING_ _ -6,480 � 1.25 1.0/.5 _DISPLAY KITCHEN _ 1.00 5,814 GEN. REC_ EPTS 7,060 �_ -� TOTAL DEMAND VA 23,860 1 AMPSI 66 48 MOTORS 4,200 W 1.0_0_ 22,240 SUPP. HEAT - 4,500 1.00 62 _ MISC EQUIP -- 0.50 E, GF E E E E E E E E E 3F, L 'F,L LCK PANELBOARD: L FAULT CURRENT: 60,581A EQUIPMENT GROUND BUS BUS AMPS: 225A AIC RATING: 65,000A SERIES RATED MAIN SIZE/TYPE: MLO SERVES: PETCO VOLTS/PHASE: 208Y/'120V, 3PH, 4W MOUNTING: FACTORY INSTALLED SECTIONS : 1 LOCATION: PRE -SALES, ROOM :118 CKT NO. DESCRIPTION VOLTAMPS PHASE IWIRE NO. BKR AMP P P BKR AMP WIRE NO. VOLTAMPS PHASE DESCRIPTION CKT NO. A B C A B C 1 NITE/EMERG/EXIT LIGHTS 500 %' "'///,;% 12 20 1 1 20 12 780 %////,% %////, GROOMING LIGHTS/EMERG (CUST) 2 3 NITE/EMERG/EXIT LIGHTS %/i'/; 500 %/ji j; 12 20 1 1 20 12 %i ,/ii; 360 BIRD/SUPPLY LIGHTS (EMP) 4 5 SALES LIGHTS (STOCK) jj' j; //% j; 720 12 20 1 1 20 12 ; ; / // ; 600 PRE -SALES LIGHTS/EMERG (EMP) 6 7 SALES LIGHTS (CUST) 660 ' // 7/7777 12 20 1 1 20 12 380 WALL PACKS 8 9 SALES LIGHTS (STOCK) /j /;; 600 /// ; 12 20 1 1 20 12 / ; 240 , / ; RR CORR/EMERG LIGHTS (EMP) 10 11 SALES LIGHTS (CUST) 600 12 20 1 1 20 12 // ,; / // ; 120 OFFICE LIGHTS (EMP) 12 13 SALES LIGHTS (STOCK) 1,020 i/ ,%; j%;/' 12 20 1 1 20 12 120 //; /i / ; BREAK ROOM LIGHTS (EMP) 14 15 SALES LIGHTS (CUST) j'///%/i 1,020 '/ '/�; 12 20 1 1 20 /; i ;, ' i i; j SPARE (EMP) 16 17 19 SALES LIGHTS (STOCK) SALES LIGHTS CUST ; j";,/; 660 , ' �j%; 540 12 12 20 20 1 1 1 1 20 20 /// ; j, ;/; / ; ;; ' ;/ /; SPARE (EMP) SPARE (STOCK) 18 20 21 SALES LIGIIfS (STOCK) ;; j;/jj/; 900 ,i, / 12 20 1 1 20 12 ',. ,� ; 342 �/;/�� LIGHTS/ADOPTION (CUST) 22 23 25 27 SALES LIGHTS CUST SALES LIGHTS (STOCK) SALES LIGHTS (CUST) % 600 /,/ ! ;' ; 600 780 /„ 12 12 12 20 20 20 1 1 1 1 1 20 ;i ///;' 11h, ; '/ % /; j // //; SPARE (STOCK) SPACE ONLY 24 26 1;SPACE ONLY 28 29 SALES LIGHTS (STOCK) '�/ /ice ' / ; 960 12 20 1 1 20 12 ,� // /; 1,179 HID LIGHTING 30 31 SALES LIGHTS (CUST) 840 12 20 1 1 20 12 1,179 / ;; / / ,� HID LIGHTING 32 33 SALES LIGHTS (STOCK) _ /%/// 480 %//i/�i 12 20 1 1 20 12 j ;" ; 1,179 j / HID LIGHTING 34 35 SALES LIGHTS (CUST) �' / �/ ;%, 540 12 20 1 1 20 12 ; //� , /, , 1,179 HID LIGHTING 36 37 SALES LIGHTS (STOCK) 120 '/% //;; ;',/ 12 20 1 1 20 ;;/ /, ; �;/ ; SPARE 38 39 SPARE j/ ; / ; ;/ /// 20 1 1 20 / /j ;SPARE 40 41 VESTIBULE LIGHTS CUST j!/%,; ' /, / /; 192 12 20 1 1 20 % / ; ; SPARE 42 SUBTOTAL 1 4,400 1 4,100 1 4,332 1 2,459 1 2,121 1 3,078 1 SUBTOTAL TOTAL PHASE A - VA AMPS 6,859 LOAD CONN. VA DF LOAD CONN. VAI DF E - EMS CONTROLLED CIRCUIT LCK - LOCKABLE TAB EX - EXISTING CONDUIT AND CONDUCTORS TO REMAIN. EXTEND AS REQUIRED. 57 COOLING HEATING 1,00 REFRIGERATION 1.00 TOTAL PHASE B - VA AMPS TOTAL PHASE C - VA AMPS TOTAL PANEL - VA AMPS 6,221 1.00 DISPLAY CASE_ 1.25 52 LIGHTING _ 20,490 - 1.25 KITCHEN T- 1.00 7,410 _ GEN. RECEP_ TS_y TOTAL DEMAND VA 25,613 1 AMPS 71 62 MOTORS _ _ SUPP. HEAT _ -�_^j _-_ _ _ _ _1.00 1.00 20,490 57 MISC EQUIP_ _ 0.50 E E VPAjNjEL130ARD. DP FAULT CURRENT: 63,786A EQUIPMENT GROUND BUS S: 800A AIC RATING: 65,000A FULLY RATED SERVES: PETCO VOLTS/PHASE: 208Y/12OV, 3PH, 4W MOUNTING: SURFACE SECTIONS : 1 LOCATION: PRE -SALES, ROOM :118 SERVICE ENTRANCE RATED CKT DESCRIPTION VOLTAMPS PHASE WIRE NO. BKR AMP P P BKR AMP WIRE NO. VOLTAMPS PHASE DESCRIPTION !CKT O. A B C A B C 1 PANELBOARD A, B & CR PANELBOARD G 17,230/;;%j/-j%j/ MF MF 225 125 3 3 3 _ 3 150 110 MF 6,859//;/ j;!///; PANELBOARD L RTU-3 2 3 %% / 15,958 jj j ; 6,221 // % i 4 5 7 9 11 ;i'%/i//'% 4,188 ��%'/;�i % i i//./ 12,484 //�' • / // /i 8,820 / %,/ ,' 74 i j//� 6 8, 820 ; j%j 10 i�%///i i % ; . �i 5,388 / / /,. �i /i 8,820 12 13 PANELBOARD AQ 9,240 ';/;; %/i; ;;i%/;! MF 125 3 _ 3 110 1 g g2p i i ' / ' /i�//i RTU-4 14 15 ii/; 7,300 ' ///�/i /i% �/ 8,820 16 // /i / 8,820 18 19 RTU-1 1 8,820 /i j ; %j ; 1 110 3 3 80 3 5,940 /, / 5,940 ' /;'' f ///%/' RTU-5 20 21 23 / !/ ii 8,820 '// 22 ' /%7ii '%%'� 8,820 5,940 24 25 27 9 31 RTU-2 VWT WATER HEATER 8,820 1 12 6 110 20 45 3 3 3 /// / ; 8,820 ; ;%% ; 1 20 / ; ;i //, ; ; SPARE 28 % / 50j/ / ; /i.� 8, 820 1 20 / / ; ;'% /, SPARE SPACE ONLY 30 32 33 35 1<37 K39 ;i%/7 50 �;%/ j 1 / ;,/ ; SPACE ONLY 34 2,300 '/� %% , � . i / 50 % /. /, , %% 3 60 4 2, 880 / „ , /; ;WATER HEATER � 38 40 ; �„ i;; 4,000 ; / /; / /; 4.992 _ ' ;/ /; 41 /i'// ii 2,300 / 0 2 SUBTOTAL 1 50,648 1 50,576 1 46-,-5-0-2-1 1 33,319 1 34,793 1 33,870 SUBTOTAL TOTAL PHASE A - VA AMPS 83,967 LOAD CONN. VA DF LOAD CONN. VA DF SL - REFER TO SINGLE -LINE DIAGRAM 700 COOLING REFRIGERATION 1.00_ TOTAL PHASE B - VA AMPS 85,369 _ HEATING _ 123,660 _1.00 1.00 DISPLAY_CA_ SE _ _ _ - 1._25_ 711 LIGHTING_ M 1._2_5 KITCHEN -- -- 1.00 TOTAL PHASE C - VA 80,372 GEN. RECEPTS _ TOTAL 40 DEMAND VA 232,U AMPS 645 AMPS 670 MOTORS_ ___-150 -_-_- 1.00 TOTAL PANEL - VA 249,708 SUPP. HEAT--- _ 1.0O AMPS 693 MIEQUIP _ __I5,352 __- - _ 0.50 A/ PANELBOARD SCHEDULES 02 REF.: NO SCALE NOTES FOR THIS DRAWING AND E1.2B 1. PAY PARTICULAR ATTENTION TO PANELBOARD CIRCUIT DESIGNATIONS, CIRCUITS ARE TAGGED AS FOLLOWS: GF) = GFCI CIRCUIT BREAKER LCK) = LOCK ON DEVICE E) = ENERGY MANAGEMENT SYSTEM (EMS) CONTROLLED CIRCUIT TS) = CIRCUIT CONTROLLED THROUGH CONTACTOR AND TIMER, SEE KEY NOTE #2 E3.2. EXAMPLE "POWER OUTLET/BAGGING" (OF, LCK) REQUIRES A GFCI CIRCUIT BREAKER WITH A LOCK -ON DEVICE. 2. ROOFTOP UNIT CIRCUIT BREAKERS SHALL BE HACR RATED. 3. CIRCUIT BREAKERS FOR FLOOR RECEPTACLES SHALL BE GFCI PROTECTED. 4. WIRE SIZE OF BRANCH CIRCUITS SHALL BE MINIMUM #12 AWG, BUT NO LESS THAN PERMITTED BY THE NATIONAL ELECTRICAL CODE (NEC) FOR SPECIFIED OVERCURRENT PROTECTION. ANY DISCREPANCY MUST BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO BID. 5. USE THE BUILDING INTERIOR AND EXTERIOR LIGHTING TO BALANCE THE LOADS ON THE SYSTEM. RELOCATE LOADS STAYING WITHIN SIMILAR BUILDING FUNCTIONS. SEE INTEGRATED POWER AND CONTROL ASSEMBLY SHOP DRAWINGS FOR BUILDING FUNCTIONS. 6. CONNECT FIRE ALARM SYSTEM AND FIRE SUPPRESSION SYSTEM ALARM DEVICES TO A#23. 7. ALL LOADS CIRCUITED TO PANELBOARD 'OR' SHALL BE ISOLATED GROUND. 8. SOME CIRCUITS ARE NEEDED FOR SERVING THE FOLLOWING ENERGY MANAGEMENT SYSTEM FUNCTIONS: (EMP) = EMPLOYEE (STOCK) = STOCK (CUST) = CUSTOMER (GROOM) = GROOMING 9. REFER TO INTEGRATED POWER & CONTROL ASSEMBLY SHOP DRAWINGS FOR DETAILS REGARDING ASSEMBLING, HANDLING, MOUNTING, FASTENING, & SUPPORTING THE ASSEMBLY, AND MAKING LINE VOLTAGE AND LOW VOLTAGE WIRING CONNECTIONS. 10. FAULT CURRENT ASSUMPTIONS: AFC=65,000A AT SERVICE ENTRANCE EQUIPMENT. EVWT I -r 1 -,r I I - V I , r I CABINET WEIGHTS FULLY INTEGRATED - - - 1100 LBS NOTE: REFER TO HILL PHOENIX SHOP DRAWINGS FOR INSTALLATION AND MOUNTING DETAILS. INTEGRATED ASSEMBLY ELEVATION 06 REF.: NO SCALE BUILDING ELECTRICAL SERVICE LOAD SUMMARY BUILDING OCCUPANCY TYPE: M BUILDING SQUARE FOOTAGE: 15,000 SERVICE DESCRIPTION: 20BY/12OV, 3PH, 4W LOAD DESCRIPTION Connected KVA I Demand FACTOR Demand KVA HVAC - SUMMER 0.00 100% 0.00 FIVAC - WINTER 123.66 100% 123.66 LIGHTING 25.64 125% 32.05 RECEPTACLES 70.78 100%; 50% 40.39 MOTOR LOADS 4.20 100% 4.20 SUPPLEMENTAL ELECTRIC HEAT 23.85 100% 23.85 MISCELLANEOUS EQUIPMENT 0.00 50% 0.00 COMPUTER LOADS 0.00 100% 0.00 EXTERIOR LIGHTING 1.58 125% 1.98 TOTAL LOAD 249.71 KVA 233.63 TOTAL AMPACITY 693.12 AMPS 648.48 SERVICE AMPACITY 800 AMPS 800.00 SPARE CAPACITY 107 AMPS 152 Jt1UYY YYINUUYY / IKAUK LIU IINU ULMANU AUDtU LOAD SUMMARY REF.: 01 NO SCALE PROFESSIONAL ENGINEER Craig R. Lanham FL PE# - 43650 )I ___I CO J Q ■ 00 VJ > < W ® ED I- 0 ®ILL 0 -j 0L Z O� O <C H 0 z U LL �■�„ ww0 W:D ® woo �v� W z LL. 55;Z O�U) M 00 N a wa ad 0� �V O6 46 zU WW or CJ �Z DISTRIBUTION: DATE: 25% REVIEW 07/19/04 75% REVIEW 07/28/04 98% REVIEW 08/06/04 PERMIT 08/13/04 ADDENDUM #1 08/19/04 HEI JOB # PETCO P.M. JOB # 0450000526 DRAWN: CHECKED: ALR BJT DRAWING TITLE: PANELBOARD SCHEDULES E1.2A J! FESSIONAL ENGINEER �raig R. Lanham FL PE# — 48650 zr �s O 0 ® F+ O U CD _ 7 C71 Z O ,pPT�I; x Z W N N Q U N � N a � WX^s JwOr z O .W W Z c(-,Az /�i r� w a) m -I J J ci 00 J Q ■ m �. 06 vJ O coo ®ILL ®-i Z c�Zfy cn IW—OOO z U u_ W:D ® ww Woa zz° W'S5�z OU)(n (V W Q 0 LL �� Id OU 06 t W W X ❑ [V DISTRIBUTION: DATE: 25% REVIEW 07/19/04 75% REVIEW 07/28/04 98% REVIEW 08/06/04 PERMIT 08/13/04 ADDENDUM #1 08/19/04 HEI JOB 8 PETCO P.M. JOB # 0450000526 DRAWN: CHECKED: LALR BJT DRAWING TITLE: PANELBOARD SCHEDULES WOOD OR THROUGH BOLT NOTES PROFESSIONAL ENGINEER TYPICAL OVERHEAD CONDUITS INTEGRATED ASSEMBLY CABINET INTERIOR STUBUP DETAIL CONCRETE BEAM Craig R . Lanham STEEL BEAM STEEL TRUSS REF.: FL PE# - TOP VIEW OF CABINET ". UNISTRUT CHANNEL (TYPIC 1. REFER TO SHEET EMS1.1 FOR AN OVERVIEW OF THE 48650 F]WqWIRING PROVIDE FIELD SIDE VIEW TO REMOTE PROVIDE FIELD 0000000c000000000 0000c�oo SUPPORT UNISTRUT TO ILDING INTEGRATED POWER & CONTROL ASSEMBLY AND THE ENERGY MANAGEMENT SYSTEM (EMS). CUH WITH INTEGRAL 24V OVERRIDE �:-,�', "'' WIRING TO RTU'S OF CABINET "~ 0000000000000000� o000000 STRUCTURE USING A OPRIATE BEAM CONTROI TRANSFORMFR peni�i c i SFQTIQN #E1 ---- --- -- -- -- CLAMP j*%,REQUI UNISTRUT _ urnnn PrAAA HcQr ........ _. 2. CONTROL WIRING, SENSORS AND OVERRIDE SWITCHES ARE _ _. _....._.. --- - �� - �",.. KHAN 5 L FAN A MINIMUM Uf J AND RELAY UNDERGROUND UNDERGROUND LAG BOLTS. SHIPPED LOOSE DIRECTLY FROM EMS VENDOR TO THE SITE FOR e .e; 'e, BRANCH BRANCH CONCRETE BEAM BE ETC. (TYPICAL). INSTALLATION. CIRCUITS CIRCUITS USE EPDXY GENERAL ANCHORS. 3. WIRING OF HVAC UNIT POWER, CONTROL AND SENSOR WIRING IS 18/2 THERMOSTAT WIRE STUBUP BY THE EC. TEMPERATURE SENSOR WIRING MUST NOT BE RUN / TOP SIDE OF LOCATIONS CONDUIT STUBBED UP NDARY DISCONNECT SWITCH IN THE SAME CONDUIT AS LINE VOLTAGE CIRCUITS. TERMINAL STRIP MAY VARY MINIMUM DISTANCE HERE REQUIRED) ACCUSTAT 24V PRESET ; FOR CONNECTION 0 DEPENDING ABOVE FLOOR INTO 4. EMS OVERRIDE SWITCHES ARE FACTORY MOUNTED IN THE FACE LH-1 THERMOSTAT OF FIELD ON CABINET 1 /2 THREADED ROD WITH VIBRATION OF THE INTEGRATED POWER & CONTROL ASSEMBLY. ONE INSTALLED ISOLATOR (TYPICAL 4 PLACES) REMOTE OVERRIDE PANEL FOR THE OFFICE IS PROVIDED BY on EQUIPMENT 0 CABINET TRANSFORM 0 50 kVA EMS VENDOR. ' ARRAINGMENT. ` (NOT TO 5. THE REMOTE PANELBOARDS 'AQ', 'G' AND 'CR' ARE PART OF THE NOTES: SCALE) (MAX) 1/2" NUT WITH LOCK WASHER. (TYPICAL INTEGRATED POWER &CONTROL ASSEMBLY PACKAGE. ALLEc D ;I Li I'l uFuu a FINISHED ° 8 PLACES) REMOTE PANELS ARE FLUSH MOUNT. THE TRANSFORMERS (IF Qo 1. THE CONTROL OF THE CABINET UNIT HEATERS (CUH) IS INDEPENDENT OF THE :.� �; "`� �': 7R' .;. ,� UNISTRUT CHANNEL (TYPICAL) SHOWN) ARE ALSO PART OF THE PACKAGE. THE MAIN o 11 FLOOR DISTRIBUTION PANEL MDP MAY OR MAY NOT BE PART OF THE W i�� 19, � � ENERGY MANAGEMENT SYSTEM (EMS). _ (MDP) o NOTES: PACKAGE REFER TO THE SINGLE LINE DIAGRAM FOR DETAILS. E-' w U l) w 2. HVAC CONTRACTOR TO FURNISH THE ACCUSTAT AND THE ELECTRICAL o _ ��-1/2" NUT 1/2" LOCK NUT AND �� w� 1 -THE UNDERGROUND CONDUITS SHOWN ARE GENERAL W - - CONTRACTOR TO INSTALL AND WIRE IT. IMUM WASHER FLAT PLATE FITTING (TYPICAL V) .. STUB -UP LOCATIONS. ' 6. PROVIDE A JUNCTION BOX AT FIVE TO SIX FEET ABOVE FINISHED r. � "' - x � co w W 8 PLACES) FLOOR (5'-6' AFF) FOR EACH SPACE TEMPERATURE SENSOR AND W ``' (0 a W � XISTRUT ANNELS AND 3. THE ACCUSTAT, WHILE NOT A CUSTOM DEVICE, IS A RELATIVELY LONG LEAD WIRE DUCT 2 - ALL CONDUITS, CONNECTORS, FIELD WIRING OVERRIDE PANEL IN OFFICE). PROVIDE 1 2" CONDUIT WITH PULL Zr��.0 t�waozo TIME ITEM. PLACE ORDER PROMPTLY TO ENSURE TIMELY DELIVERY. (INCLUDING REMOTE PANELBOARD FEEDERS BRANCH MPONENTS ARE BASED ( ) / ot� ovio�o w 1000 CHANNELS. STRING FROM JUNCTION BOX TOEITHER A) 12'-0" AFF IF NO s 11w CIRCUIT, NEUTRAL, AND GROUND WIRING) IS FURNISHED �--� XzORMER TO UNISTRUT CEILING OR B) JUST ABOVE CEILING WHERE CEILING EXISTS.pCti n wAND INSTALLED BY THE ELECTRICAL CONTRACTOR. INSTALL SENSOR AND WIRING AS FURNISHED BY EMS VENDOR. �► ® bi X � X "j trw ACCUSTAT LH-1 WIRING DIAGRAM 20 CONDUIT ENTRY DETAIL 18 TRANSFORMER MOUNTING DETAIL 17 7. ALL WIRING MUST BE RUN IN DESIGNATED PANDUITS. THE rr'' U�_j BOTTOM OF THE CABINET IS INTENTIONALLY LEFT OPEN FOR kit `o REF.: MIA, E1.1, E2.2 NOSCALE Z � � m REF.: None REF.: 12/E3.2 None LATERAL RUNS OF LARGE CONDUCTORS THROUGH THE CABINET w wr TO THE SUBPANELS, IF REQUIRED. 8. THE CAGE ROOM CONTACTOR/TIMER ASSEMBLY IS PART OF THE CONTACTOR SCHEDULE CONTACTOR EMS FUNCTION CIRCUIT CONTROLLED (VIA CONTACTOR POLE INDICATED) LOAD DESCRIPTION A B C 1 2 3 4 5 6 7 8 9 10 11 12 D 1 1 EMPLOYEE LIGHTS L#4 L#6 A#6 L#10 L#12 L#14 L#16 L#18 - LIGHTING IN WORK & ISO ROOMS, BIRD ROOM, PRESALES, TOILET ROOMS, MANAGER'S OFFICE, BREAK ROOM 2 1 EMPLOYEE LIGHTS A#4 A#24 A#30 B#3 B#9 B#35 B#37 B#39 B#41 - - DOCK LIGHT, EXHAUST FANS, BIRD CAGES, SMALL ANIMAL HABITAT, QUICK TAG, EWC 3 4 2 STOCK LIGHTS L#5 L#9 L#13 L#17 L#21 L#25 L#29 L#33 L#37 L#22 L#24 L#20 - SELECTED LIGHTING IN RETAIL AREA 3 CUSTOMER LIGHTS L#7 L#11 L#15 A#12 L#19 L#23 L#27 L#31 L#35 L#39 L#41 - REMAINING LIGHTING IN RETAIL AREA EXCEPT HID LIGHTING 5 3 4 CUSTOMER LIGHTS GROOMING LIGHTS A#2 A#10 A#14 A#16 A#18 A#20 A#22 A#25 END CAP DISPLAYS, VALANCE LIGHTING, MISCELLANEOUS 120V LOADS 6 L#2 - - - GROOMING LIGHTING 7 8 5 6 AQUARIUM TANK LIGHTS HID LIGHTS B#26 B#28 B#30 B#32 AQUARIUM TANK LIGHTS & POLES L#30 L#32 L#34 L#36 HID LIGHTING 9 10 11 7 a 9 EXTERIOR SIGNS PARKIN6 LOT LIGI ITS SECURITY LIGHTS A#8 8#14 8#16 B#18 EXTERIOR SIGNS, DISPLAY WINDOW RECEPTACLES L#38 L#40 L#42 L#28 -P­ARKfNNG-Iz&T-b PERIMETER WALL PACKS L#8 - INTEGRATED POWER & CONTROL ASSEMBLY PACKAGE AND MUST BE FIELD INSTALLED BY THE EC. SEE SHEET E3.2 FOR LOCATION. 9. UNLESS OTHERWISE NOTED, WIRING SHOWN SOLID IS FIELD INSTALLED, AND WIRING SHOWN DASHED IS FACTORY INSTALLED BY PETCO'S VENDOR. IE 10. FIELD VERIFY EXISTING GROUNDING AT LANDLORD'S SERVICE ENTRANCE EQUIPMENT. IF REQUIRED, METHOD(S) SHALL BE IN ACCORDANCE WITH LOCAL REQUIREMENTS. PERFORM A FALL OF POTENTIAL TEST TO ENSURE MAXIMUM EARTH GROUND RESISTANCE OF 25 OHMS AS REQUIRED BY NEC. IF THE TEST REVEALS MORE THAN 25 OHMS, CONTACT THE ENGINEER OF RECORD. IF LESS THAN 25 OHMS ARE DISCOVERED, EC IS REQUIRED TO INSTALL AT MINIMUM THE COLD WATER SERVICE GROUND, BUILDING STEEL GROUND, GAS AND FIRE SUPPRESSION SYSTEM PIPING GROUND, UFER (NEW CONSTRUCTION ONLY), AND GROUND RODS. ALL INTERIOR METAL PIPING SHALL BE BONDED TO THE SERVICE EQUIPMENT ENCLOSURE PER NEC. -i CO 11. NOT USED J 12. WHERE A REMOTE MAIN DISCONNECTING MEANS IS REQUIRED (SUCH AS FOR OUTSIDE DISCONNECT FOR FIRE PROTECTION IN ca � A MULTI -TENANT USE), PROVIDE THE FOLLOWING: U CL Z J CIRCUIT BREAKER IN MDP: ,®, LL 06 FOR 208/120V SERVICE: CUTLER -HAMMER # SN4RP11K - 120V ❑ ❑ COIL (FOR LD MAIN BREAKERS) ADD ON SHUNT TRIP MECHANISM U, FOR 600A MCB IN MDP [� 1 1 1 O m ISOLATED GROUNDING (IG) IS MISSION CRITICAL AND MUST BE IN FEEDER SCHEDULE: 120V-1PH POWER FROM SPARE CIRCUIT B#1 0J. z W D o STRICT ACCORDANCE WITH THESE DRAWINGS, THE INTEGRATED TO EXISTING 208/12OV, 33 30A (3)#8, (1)#80, (1)#8 IG 3/4" C BREAK GLASS STATION FOR SHUNT TRIP, MODEL AND LOCATION Q F- 0 -j POWER & CONTROL ASSEMBLY MANUFACTURER'S SHOP DRAWINGS 1 UTILITY TRANSFORMER. PER THE DIRECTION OF THE LOCAL AUTHORITY HAVING 0 Cn z U LL AND PETCO MIS DEPARTMENT RECOMMENDATIONS. DO NOT t24 125A, (4)#1, (1)#60, 1-1/2" C JURISDICTION. �, i U LLI L7 PROVIDE OOA CT CABINET METER AND FUSED DEVIATE WITHOUT WRITTEN AUTHORIZATION. ALL CIRCUITS SERVED C/T M 8U4 800A, (3) 3" C, EACI I W/ (4)#300kcmil, 13. PROVIDE THE TELEPHONE WIRE FROM MAIN TELEPHONE BOARD w D 0 W 0 NEMA 3R ICE ENTRANCE DISCONNECT AS RTU TO THE INTEGRATED POWER & CONTROL ASSEMBLY FOR EMS U 0 BY PANELBOARD 'CR' ARE TO BE ISOLATED GROUND. AN Z Z SHOWN FROM UTILITY TRANSFORMER. (�, (� I-- LL SYSTEM COMMUNICATION BUSS. ROUTE TELEPHONE WIRE ISOLA-FED GROUND WIRE IS TO BE RUN FROM THE SOURCE (I.E. COORDINATE CONNECTIONS WITH UTILITY - TYPICAL ROOF -TOP HVAC UNIT L1J : Z - SE RATED THROUGH GROMMETTED KNOCKOUT AND SHALL CONNECT THE EITHER THE SERVICE ENTRANCE OR SEPARATELY DERIVED SYSTEM COMPANY PRIOR TO ROUGH -IN. 1800A REFER TO MDP FOR QUANTITY AND WIRE TO THE MODEM INSIDE THE CABINET. THE WIRE IS 0. 0 � - WHICHEVER IS ELECTRICALLY CLOSER TO PANELBOARD 'CR') TO 3P CONDUCTOR / CONDUIT SIZES SEPARATE AND INDEPENDENT OF THE TELEPHONE SYSTEM THE ISOLA-FED GROUND BAR IN PANELBOARD 'CR'. FOR FURTHER i800A EQUIPMENT AND WIRING THAT IS PROVIDED BY PETCO'S • KRP-C INSTALLATION INFORMATION SEE IEEE STANDARD 1100 ("POWERING I NEMA 3R R-FU DISCONNECT. AND GROUNDING SENSITIVE ELECTRONIC EQUIPMENT"), CHAPTER 9, - I REFER TO E2.2 FOR 14. REFER TO SHEE'r E2.3 FOR PROVISIONS FOR NETWORK SECTION 9.10,12. ANY DEVIATION FROM THIS WILL REQUIRE MORE INFORMATION. CONNECTIONS TO EMS. ° a IMMEDIATE RECTIFICATION BY THE CONTRACTOR AND POSSIBLE CD CD 0 REIMBURSEMENT FOR DAMAGES CAUSED BY FAILURE TO COMPLY. _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ •�} p ROUTE ISOLATED GROUND CONDUCTOR (GREEN WITH YELLOW 00OCT STRIPE), INDEPENDENT AND UNCONNECTED TO OTHER GROUND I I a WIRES, IN PARALLEL WITH PANELBOARD FEEDERS ALL THE WAY �Q TO THE GROUND SOURCE (I.E. EITHER THE SERVICE ENTRANCE OR I F8oOA MLO I wu) SEPARATELY DERIVED SYSTEM - WHICHEVER IS ELECTRICALLY I MAIN DISTRIBUTION PNLBD (MDP) --- VWT CLOSER TO PANELBOARD 'CR'). TO TEST, LIFT THE ISOLATED GROUND WIRE FROM THE LUG AT THE GROUND SOURCE AND TEST © 25rrsiREVI: VarE: 25% REVIEW 07/19/04 AT PANELBOARD 'CR' THAT THERE IS NO CONTINUITY BETWEEN IG I I AND EQUIPMENT GROUND BUSES. AT COMPLETION OF TEST, I I 75% REVIEW 07/28/04 REATTACH IG TO GROUND SOURCE LUG AND VERIFY THAT NOW - - - - I ( - - - 98% REVIEW 08/06/04 THERE IS CONTINUITY BETWEEN IG GROUND BUS AND EQUIPMENT METAL PIPING WITHIN BUILDING PERMIT 08/13104 GROUND BUS AT PANELBOARD 'CR'. #12 I I ADDENDUM #1 08/19/04 #2/0 UFER I I I I N H WOMEN'S N-41 EMS I i 108 i�osEr IG- ❑IG BARE COPPER TO BUILDING STEEL & SIDING I I I I N N M0N S ���L_ CAGE ROOM ISO ROOM ! `� i PNLBD 'G L 105 117 t� f /; 106 TUB ROOM G I I I WORK ROOM / TYPICAL IG RECEPTACLE #2/0 BARE FOR PNLBD 'CR' 05 F - - � I I 11a I L �\ �. , ' � � � _ -� _ � � - -$ GROOMING E1.3 I \ I ( CLOSET - I SALON 10 120 BREAK RM I PNLBD �/AQ' / -� -\ ��� ° GROOMING RECEPTION TRANSFORMER SCHEDULE112 CLOSET I I� ( 104 riEiJOB tt PETCUP.M.JUl3tJ #2/0 BARE PNLBD PNLBD PNLBD PNLBD I PNLBD PNLBD CONTACTOR 110 _ �� _ .o VESTIBULE < # KVA PRIMARY SECONDA EET REF, COLD WATER MAIN 33 /TIMER !- _� _ _. _�_ �__� _ ___0101104�0000�26 ,CR, , ♦ , 'B1 )LI 'AQ' 'G' CABINET PRE -SALES I i > -_i ._ _� AQUARIUM UIinWN: CHECKED: H �C �-,,• • `c% AREA ALR BJT T1 75 480V V ES E2.2 tts J_ \- Ir / PtJLBD 'CR' 11� r T2 30 480 2 V REAKROOM E3.2 Y T3 30 4 GROOMING E3.2 _ __ �• R_ OFFICE t 13 DRAWNG TITLE: (4) 5/8"X10' GND RODS 10' O/C L - - - - - - - c3 -I �- - �- -� -� ELECTRICAL 1. S eGH ROTECTED BY MOB WITHIN 10' CABLE LENGTH II `� - --- s ��- ECO SINGLE LINE DIAGRAM PNLBD MDP' 2. EFFICIENCY (EE) TRANSFORMERS COMPLYING WITH NEMA INTEGRATED POWER & CONTROL ASSEMBLY INTEGRATED POWER AND AND -1 IN CA MA MN RI VT NY AND THE CITY OF SEATTLE CONTROL ASSEMBLY DETAILS SINGLE LINE DIAGRAM DETAILS 05 SINGLE LINE DIAGRAM 02 KEY PLAN 01 REF.: 02/E1.3 NO SCALE REF.: None REF.: NO SCALE E 1 1 .3 x I I ' I I i I I I I 1 —:—__T_=- =ter_ — c I �..� AQ#2 kB#9 EF1- `� ao r= ---- - i I� �B III I I / I #21 A#21 5 B A#15'` 10'-0" AFF \ L_ 11 MDP#14;16,18 1 1 200/3/110. / - -, t�)EMA 3R fl ' . y'f 1 I ..� RTU -/ ��A33 i AQ#6 AQ#8 �. MDP#8,10,12 2219 200/3/110 NEMA 3R2217 )IR 1 ❑g ���, :.:..::•:.::i RTU > f _ f NOTES REF.: GENERAL ELECTRICAL NOTES: 1. SEE LARGE SCALE PLANS FOR DETAILS OF THOSE AREAS. (g A) r �� 2. SEE 20/E3.2 FOR ACCUSTAT WIRING DIAGRAM FOR CUH-1. 3. LOCATE SENSOR JUNCTION BOXES AT 6'-0" AFF IN RETAIL, ALL OTHERS AT 5'-0" AFF EXCEPT WHERE SPECIFICALLY NOTED OTHERWISE. l I ; ( I 4. ALL DEVICES NOT SPECIFICALLY DIMENSIONED MAY BE LOCATED -+-/- 8" IN EITHER DIRECTION IN PLAN FROM THEIR APPROPRIATE LOCATION SHOWN (TO NEAREST STUD OR NEAREST CMU CORE). ALL DIMENSIONS ARE FROM INSIDE FACE OF UNFINISHED WALL. I I ' 5. VERIFY LOCATION OF ALL DEVICES, POWER POLES, ETC., WITH LATEST FIXTURE PLAN. 1 6. INSTALLATION OF ELECTRIC PANELBOARDS SHALL BE IN ACCORDANCE WITH LOCAL CODES 7. WIRE SMOKE DETECTION TO B#2, AND MAKE PROVISION FOR FAN SHUTDOWN _._ _._.. _r .__.___ _______ _____✓) _. _ _ —JL— _ __JL _ _ _.. __J ! 1 AND FIRE ALARM SIGNAL CIRCUIT. J 13 ____ ____ I ELECTRICAL KEY NOTES: EF-I U I 1 - ,' \!� �- I I ❑ RECEPTACLES ABOVE SHOW WINDOWS. l'-O" ABOVE TOP OF STOREFRONT. ❑2 SERVICE ENTRANCE DISCONNECT, UTILITY COMPANY CT AND METER ASSEMBLY. 1 COORDINATE WITH UTILITY FOR ALL REQUIREMENTS. TYP 16 -_(�B 41/ �1 DIFI- (_� I I ❑3 MAIN TELEPHONE BACKBOARD, 4' X 8' X 3/4" PLYWOOD. REFER TO 17/E3.1. [J _ AUTOMATIC DOOR, CIRCUIT INDIVIDUALLY AS INDICATED. VERIFY EXACT EF- - LOCATION AND CONNECTION. B3-� -�.____._ ��-_- ,`°`; '`�., ` N� I 1 �1 - -- I ❑5 BUZZER, EDWARDS #725. MOUNTED IN JOIST SPACE. CIRCUIT TO A#28. -- `� - 6 PUSH BUTTON FOR DOOR BUZZER MOUNTED AT 54°AFF. PROVIDE ALL WIRING �5 AND CONNECT TO BUZZERS PER MANUFACTURER'S INSTALLATION "'.••FM .' -, ) - INSTRUCTIONS. CONNECT O CIRCUIT A#28. — II I I J- - 11 DP#�,5,27,29 I.......�" _ 7PROVIDE JUNCTION BOX AT BOTTOM CORD OF BAR JOIST FOR "ANIMAL 900/ "/110 � �-I PETTER' DISPLAY. PROVIDE TYPE ALT (ALUMINUM LIQUID TIGHT) CONDUIT, BLACK, AND CONDUCTORS AS REQUIRED AFTER DISPLAY HAS BEEN SET AT 3FZ❑gII TIME OF STORE FIXTURING WHILE VENDOR IS ON SITE. PROVIDE MC CABLE ::2.::....:` �• JIINSIDE DISPLAY AND MAKE FINAL CONNECTIONS TO HABITATS AS REQUIRED. 22 24 R0 SQUARE D CLASS 2510 #KO3 MANUAL SWITCH OR EQUAL FOR UNIT HEATER. :_ _ _ ❑❑; 9 1 MOUNT SWITCH ON WALL ABOVE CEILING. 22 17 - IL `JI A#32 , y022 I - G#221 I I i ❑ PROVIDE RTU DISCONNECT SWITCH AS SHOWN. - - �/ I I 20 � ` _I ^ .�??�_ _ 10 INTEGRATED POWER & CONTROL ASSEMBLY. REFER TO SHEETS E1.2A, E1.213, /ter- ------ _ - A#387,\ E1.3 AND EMS1.1. 7 I A # 8 I I I 11 GFCI DUPLEX RECEPTACLE WITH WEATHERPROOF, UNATTENDED, WHILE -IN -USE n \ 2219 1 I I I f I COVERPLATE FURNISHED WITH HVAC UNITS. __.__ ___.❑_________� I - ---- 12• POWER POLE ON MULLION FOR QUICK TAG AND SODA COOLER, WITH RECEPTACLE TO CIRCUIT A#24 AND A#26, RESPECTIVELY, IF FURRED OUT (�-I---;�� - I A/�SZ ! I I WINDOW BASE EXISTS, PROVIDE DUPLEX RECEPTACLE IN LIEU OF POWER POLE. 10! RECEPTACLES ARE TO BE GRAY IN COLOR. II .02 '-0" I 4 I I � - 3. 2219 1 i ! ' (I 1 J SWITCH FOR EXHAUST FAN. HUBBELL NUMBER CS1221 OR EQUAL. #31 PROVIDE 3'-0" HORIZONTAL SECTIONS OF PLUG MOLD ALONG ENTIRE FIXTURE - _A#16 �Ls � CR #9 BOTH SIDES, 6" ABOVE BASE OF GONDOLA WITH OUTLETS EVERY 2'-0". CIRCUIT -_- - 4� 0 - -= _= 12 ! ! AS SHOWN. it I (� 4 ! I 17 22 / !� '- _❑ !, /3 ti B#2� ! ! 15 JUNCTION BOX MOUNTED DISPLAY CONNECTED TO AT BOTTOM EMS CONTROLLED CHORD OF BAR JOIST FOR END CUSTOMER LIGHT CIRCUIT. CAP `. V P� 1� ,2 3 --� _ i"- -"'" � ���; �#2,4 4 -_� !_� - CONTRACTOR TO DROP CONDUCTORS RACKING TO BASE. VERIFY LOCATION IN 3/4" CONDUIT DOWN SPINE WITH PE NCO PROJECT MANAGER OF PRIOR T0 q#40. B 1 200% /110 i INSTALLATION. SEE DETAIL 13/E3.1. LABEL WITH CIRUM NUMBER. CONDUIT �� 11 EMA 3R - - - - - - — ! PAINTED PER ARCHITECTURAL PLANS. ;� q g 10 JUNCTION BOXES MOUNTED AT BOTTOM CHORD OF BAR JOIST FOR LIVE ANIMAL .: `'...........'......... �/ _. ! DISPLAY. DROP POWER T DISPLAY AFT DISPLAY R iU / 7 r E 0 ER I PLAY HAS BEEN SET AT TIME OF _C i- 5 I ff STORE FIXTURING WHILE VENDOR I N ITPROVIDE � I II S O SITE. MC CABLE INSIDE _.......,❑.Q / _ / I I ,� ( I DISPLAY AND MAKE FINAL CONNECTIONS TO HABITATS AS REQUIRED. �_ 17 PROVIDE TYPE SJ-T, 12 AWG, COILED POWER CORD (SIMILAR TO RAPID CONN A#34 <{�� I - - I - DWG. NO. RC-207-0046, EXCEPT IN BLACK) FROM THE BAR JOIST MOUNTED _I JUNCTION BOX TO THE DISPLAY. BUS DROP GRIPS (HUBBELL CAT. NO. 073041278) SHALL BE PROVIDED AT EACH TERMINATION POINT AND A SAFETY \ �❑ —J I ; J SPRING SHALL BE PROVIDED WHERE THE CABLE DROPS DOWN FROM THE - - �I---' -- CEILING. THE VERTICAL PORTION OF THE CABLE DROP SHALL BE PLUMB. \ f 18 OUTLET FOR WATER COOLER TO BE GRAY IN COLOR. I ✓� \ I ___ ;� 19 J-BOX MOUNTED AT BOTTOM CHORD OF BAR JOIST FOR FIXTURE END CAP B 5 V \ � I 04 _ ' �1 DISPLAY. PROVIDE CONDUIT DROP SIMILARLY TO 13/E3.1. 1 \ J. r I 'i I `�� � �� � � 20 LOCATE RECEPTACLE WITHIN 3'-0" OF GROOMING ROOM FOR GROOMING SIGN, 12" \ ! . \ ABOVE TOP OF STOREFRONTIF NO STOREFRONT EXISTS AT THIS LOCATION, _ ___ i \ `�' I EF PROVIDE CEILING RECEPTACLE OVER GROOMING VESTIBULE DOOR. DUPLEX RECEPTACLE ON UNISTRUT IN JOIST SPACE FOR SECURITY MONITOR. CIRCUIT AS SHOWN. i' •_ I 22 VERIFY EXACT ELECTRICAL REQUIREMENTS AND LOCATIONS WITH PETCO PM 3. i PRIOR TO ROUGH IN. 1 , I I ELECTRICAL POWER PLAN REF.: WOMEN'S 108 MEN'S 109 ISO ROOM 117 WORK ROOK 118 CLOSET 120 BREAK RM 112 CLOSET 110 PRE -SALES 02 KEY PLAN 1 /8" = V-0" REF.: PROFESSIONAL ENGINEER Craig R. Lanham FL PEA — 48650 -- _ CAGE ROOM 105 TUB ROOM 106 - -:4 GROOMING 17 SALON -_f 107 -_3 GROOMING RECEPTION Ill 04 o VES rIBULE 101 AREARIUM 115 OFFICE Ill 1-3 IV 01 NO SCALE 0 0 I� o w ® p C - �„j„� 01 r� cn (0 r_ n W `i (/) m d) ..���w ®Cr F UV 0 GO WV) �vi0wo Wvr �Yp�IC)�W �� ryl y r0 L t 'rCl O U — W W (' 0 Ul W � f� .. w_ J W LL H In m • 0 LL .... 06 z U) j <w Om ❑ O -' 0�Z� D ¢ IW F— ®- ° 0Lu0 U W 0 W () Z Z 0 r� 0-U) L� ��Z OLIJ U)U) �^ � 0 s Z o O J ()U oO 9 = W w rr o N L DISTRIBUf10N: DAFE: 25% REVIEW 07/19/04 75% REVIEW 07/28/04 98% REVIEW 08/06/04 PERMIT 08/13/04 ADDENDUM #1 08/19/04 HEI JOB it PEfCO P.M. JOB tl 0450000526 U[MVVN: CHECKED: ALR BJT DRAWING ME - ELECTRICAL POWER PLAN E 2.2 V I �� EF-7 FAN MOTOR rY SPEED CONTROL r W JUNCTION BOX POWER TERMINAL BLOCK B#10,12 L1 I E CUH-2 24V TRANSFORMER & CONTROL RELAY �-24V TRANSFORMER z tl @ Y W POWER ACCUSTAT CIRCUIT LMS-AH11 FOR FAN B#15 ACCUSTAT LMS-AH11 WIRING DIAGRAM 20 REF.: M1.1,E1.1,E2.2 NONE im I -AQ#34;36` AQ#40,42 --�- - l +36",+72" +36",+7� " �QW 01=- 18' AQ#30,32 18 +36",+72' � I Q#?2 \--- I F,:I-+42 C-fL Q#22 =© -I i- � _I 18 -- -- _ AQ#22 QQ#14,16 +t 6", +72" � I AQ#18,20 \ 16", +72" ( I E PAN ELB "AQ„ 24 AQ#1 AQ/� 7 GFI I,I 44" I I V I 1111 I �6DP#37,39 0/3//NF I I AQ#3 I LARGE SCALE BATHROOM AREA PLAN REF.: 02/E2.2 ELEVATION 1 C C C u ELEVATION 2 NOTES: I. DEVICES DIMENSIONED LATERALLY SHALL BE LOCATED +/- 2" FROM LOCATION INDICATED. 2. DEVICES NOT DIMENSIONED LATERALLY MAY BE FASTENED TO NEAREST STUD. OFFICE WALL ELEVATIONS 14 REF.: 09/E3.2 1/4"=1'-011 NOTES: 1. ALL DEVICES IN THIS DETAIL ARE MOUNTED AT 1'-6"AFF EXCEPT WHERE NOTED OTHERWISE. LARGE SCALE OFFICE PLAN 09 REF.: 02/E2.2, 02/E2.3 1/4"=1'-011 05 LARGE SCALE BIRD ROOM PLAN 1/411=l'-0" REF.: 02/E2.2 04 1/411=11-011 H N H N IG IG G TYPICAL IC RECEPTACLE FOR PANEL 'CR' NOTES: 1. TYPICAL CASH WRAP DETAIL. VERIFY NUMBER AND LOCATION WITH ARCHITECTURAL PLANS. PROVIDE ADDITIONAL BRANCH CIRCUITS AS NECESSARY 2. THIS DETAIL IS SCHEMATIC IN NATURE. REFER TO FURNITURE LAYOUT AND ORIENTATION, AND FOR ROOM LOCATION FOR CONDUIT DESTINATION. 3. THERE WILL BE A FLOOR SURFACE CABLE CHASE PROVIDED BY THE PETCO VENDOR, WHICH CONNECTS THE FRONT AND REAR CASH WRAP SECTIONS. ROUTE DATA, TELEPHONE AND MC CABLE POWER WIRES THAT FEED THE REAR CASH WRAP SECTION UNDERNEATH, ABOVE FLOOR. N LARGE SCALE P.O.S. AREA PLAN REF.: 02/E2.2 LARGE SCALE GROOMING AREA PLAN REF.: 02/E2.2 17 NO SCALE NOTES REF.:' GENERAL ELECTRICAL NOTES: 1. ALL POWER POLES, OTHER THAN THE CASHIER AREA, ARE BY THE CONTRACTOR. SEE SHEET E2.2 FOR SALES AREA POWER POLE LOCATIONS. 2. ALL DEVICES NOT SPECIFICALLY DIMENSIONED MAY BE LOCATED +/- 8" IN EITHER DIRECTION IN PLAN FROM THEIR APPROPRIATE LOCATION SHOWN (TO NEAREST STUD OR NEAREST CMU CORE). 3. CONTRACTOR SHALL RETURN TO THE SITE TO MAKE FINAL CONNECTIONS TO PETCO'S EQUIPMENT AS NECESSARY. ELECTRICAL KEY NOTES: ❑1 DEDICATED NEMA 5-20R RECEPTACLE FOR FAN CAGE 0#13, 2-0 AFF. ❑2 TIMER ASSEMBLY BY INTEGRATED POWER AND CONTROL ASSEMBLY MANUFACTURER. WIRE (TS) CIRCUITS AS SHOWN ON PANELBOARD 'G' SCHEDULE TO TIMERS. ONE TIMER FOR EACH CIRCUIT. LABEL EACH TIMER FOR CIRCUIT NUMBER. MOUNT SUCH THAT TOP SWITCHES ARE 48" AFF. SOUND SYSTEM 7'-0" AFF, VERIFY EXACT LOCATION IN FIELD. ® EQUIPMENT FOR SOUND SYSTEM AT 7'-0". VERIFY LOCATION IN FIELD. �5 DUPLEX RECEPTACLE UNDER THE COUNTER FOR SECURITY EQUIPMENT CIRCUIT AS SHOWN. © WEATHERPROOF RECEPTACLE WITH IN -USE COVER. GRANGER/RACO #5081-Q4, 3/4" COVER DEPTH. INSTALL AT 4'-0" AFF. �7 SQUARE D CLASS 2510 #KO3 MANUAL SWITCH OR EQUAL FOR UNIT HEATER. MOUNT SWITCH ON WALL ABOVE CEILING. ® DATA OUTLETS IN THIS AREA SHALL BE MOUNTED 42" AFF. CONDUITS TO TERMINATE IN FREE AIR AT BOTTOM OF ROOF STRUCTURAL MEMBERS OF RETAIL SIDE OF MANAGER'S OFFICE WALL. 0 TWO COMPARTMENT POWER POLE FURNISHED BY PETCO VENDOR, INSTALLED AND WIRED BY E.C. SEGREGATE POWER WIRING FROM DATA AND TELEPHONE. FASTEN SIMILARLY TO 14/E3.1. 10 JUNCTION BOX WITH DUPLEX OUTLET FOR MODEM, LIGHT FIXTURE, AND OTHER GENERAL OUTLET CIRCUIT. 11 DEDICATED RECEPTACLE FOR 2-HOSE DRYER (TYPICAL). 12 COORDINATE THE LOCATION OF CONDUITS WITH THE OWNER'S FURNISHINGS AND OTHER TRADES. REFER TO ARCHITECTURAL PLANS FOR DESIGNATED, LIMITED AREA FOR CONDUITS AND OTHER TRADES' WORK. 13 RECEPTACLE FOR WASHER. PROVIDE ENGRAVED LABEL "WASHER." COORDINATE LOCATION WITH WASHER WASTE HOSE BOX. 14 DRYERS ARE PROVIDED IN ONE OF TWO CONFIGURATIONS: 3-POLE, 4-WIRE AND 3-POLE, 3-WIRE. THE 3-POLE, 4-WIRE CONFIGURATION (TWO HOT, ONE NEUTRAL, ONE GROUND) COMES WITH A NEMA 14-30P PLUG. PROVIDE A NEMA 14-30R RECEPTACLE. THE 3-POLE, 3-WIRE CONFIGURATION (TWO HOTS, ONE GROUND) COMES WITH A NEMA 10-30P PLUG. PROVIDE A NEMA 10-30P RECEPTACLE. SINCE EITHER MAY BE PROVIDED WITHOUT ADVANCE WARNING, PROVIDE FIVE #10 AWG WIRES IN EITHER CASE. 15 ATTACH PETCO PROVIDED CORD KIT TO APPLIANCE. 16 DISCONNECT FOR DOMESTIC HOT WATER HEATER. PROVIDE #3/0 BONDING JUMPER BETWEEN HOT AND COLD WATER PIPES. 17 PROVIDE JUNCTION BOXES MOUNTED TO TOP OF BIRD ROOM, WITH CONNECTION TO WHIP FROM BIRD ROOM PLUGMOLD. PLUGMOLD IS INTEGRAL TO BIRD ROOM. DROP POWER FEED THROUGH DISPLAY "TREE" TO BIRD ROOM CEILING AFTER DISPLAY HAS BEEN SET AT TIME OF STORE FIXTURING. PROVIDE TYPE ALT (ALUMINUM LIQUID TIGHT) CONDUIT, BLACK AND CONDUCTORS AS REQUIRED. CIRCUIT TO A#4. 18 CONVENIENCE RECEPTACLES IN THIS ROOM ARE GFCI PROTECTED AT THE ELECTRICAL PANELBOARD. 19 DEDICATED CIRCUIT FOR CASH REGISTER AND CARD READER. ALL 'CR' CIRCUITS ARE ISOLATED GROUND. 20 THIS RECEPTACLE IS DEDICATED TO THE WORK ROOM FREEZER. CONFIRM LOCATION WITH FINAL FIXTURE PLAN. 21 DATA JACK FOR FUTURE NETWORK CONNECTION FOR ENERGY MANAGEMENT SYSTEM (EMS) TIE-IN (AT EMS PANEL). SEE 02/E2.3. 22 DEDICATED RECEPTACLE AT 9'-0"AFF. 23 SINGLE GANG JUNCTION BOX WITH 3/4" CONDUIT TO BAR JOIST FOR SECURITY SYSTEM INSTALLER'S USE. 24 COORDINATE LOCATION OF THIS ELECTRIC PANELBOARD W. �TH PROVISIONS FOR OTHER TRADES, SUCH AS WOOD BLOCKI,ri. FOR GENERAL CONTRACTOR'S USE. 25 ACCUSTAT FOR BIRD ROOM. LOW VOLTAGE CONTROL WIRING SHALL BE FISHED DOWN IN WINDOW, NO EXPOSED WIRING OR CONDUIT PERMITTED. SEE DETAIL 20/E1.3. WOMEN'S CLOSET 108 6114 MEN'S 109 � r r -- �_-------- � � I- t�CAGE ROOM ISO ROOM '\ 'ja 105 / TUB ROOM 117 ; ` "� E3.2 106 WORK ROOM\ /( 118 �;, ,'i%f i •a i y" i , : - GROOMING CLOSE SALON % �\ ,� -�' j -' �\\ ; / 120 GROOMING BREAK RM RECEPTION 104 CLOSET r / p , _ , • _ c3 VEST !TRUCE El PRE -SALES _t �, — - -E3 2 PROFESSIONAL ENGINEER Craig R. Lanham P E ## — 02 KEY PLAN 11411=1'-011 REF.: AREARIUM J - \ 115 04 E3 217 //� 013 CE 09wm E3.2 01 NO SCALE J co J J r ,, V CO [l. Z J ILL 06 Z U) CK>}- �W 0 -M1_0 0. U Q IW-O�O U) Z C) ILL n�n I.L. W W 0 z0 0- U) � � z U) U) N Q 0 •� 0 LL �v ed °o UU zW w �o lV WYn DISrRIBUTION: DATE: 25% REVIEW 07/19/04 75% REVIEW 07/28/04 98% REVIEW 08/06/04 PERMIT 08/13/04 ADDENDUM t/1 08/19/04 HEI JOB H PETCo P.M. JOB # 0450000526 DRAWN: CHECKED: ALR BJT DRAWING TITLE: ELECTRICAL LARGE SCALE PLANS AND DETAILS E 3.2 i I 2fIJ a .