Loading...
HomeMy WebLinkAbout563 N White Cedar 05-790 Fire prevention divisionr I i � - toj� SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 4 301 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772 (407 302-2520 / FAX (407) 302-2526 Plans Review Sheet Date: December 8, 2004 Business Address: 555 N. White Cedar Road Occur. Ch.38 Business Business Name: Sanford Recycling Ph. 0 FAX () Contractor: Mc Kee Construction Ph. (407), 323-1150 FAX (407)323-9304 ., Reviewed [ ] Reviewed with `comment[X� Rejected [ ] ...... Reviewed by: Timothy Robles, Fire Protection Inspector/plans Examiner Comment: Plans reviewed as Business Occupancy. FD reserves right to require applicable code requirements if occupancy use changes. 1,920 sq ft building 1.1 Application —New Building. 1.2 Mixed — N/A 1.3 Special Definitions — Meets F.F.P.C. - 6.1.11.1 (Record keeping/Business transactions). 1.40assification of Occupancy — Business F.F.P. C. 1.5 Classification of Hazard of Contents — Ordinary/6.2.2.2. * 1.6 Minimum Construction — N/R 2.2 Means of Egress Components — O.K. 2.3 Capacity of Egress — One person per 100 sq ft (50 or more occupants shall comply with 44' isle ways 2.4 Number of Exits — O.K. two remote exits (less than 75' ft OK) 2.5 Arrangement of Egress — O.K., will field verify 2.6 Travel Distance — O.K. 1 SANFORD FIRE DEPARTMENT -. . FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772 (407 302-2520 /FAX (407) 302-2526 2.7 Discharge from Exits — O.K., will field verify 2.8 Illumination of Means of Egress — O.K.; will field verify 2.9 Emergency Lighting — O.K.; will field verify 2.10 Marking of Means of Egress — O.K.; will field verify? 2.11 Special Features — 3.1 Protection of Vertical Openings — 3.2 Protection from Hazards — N/N 3.3 Interior Finish — Class "A " 3.4 Detection, Alarm and Communications Systems —Not Required 3.5 Extinguishing Requirements — as per NFPA 10 — Two (2) 3A rated fire extinguishers required in this building mounted at 36 " from floor to bottom see blue prints 3.6 Corridors — 4 Special Provisions - 5 Building Services 5.1 Utilities — 5.2 HVAC — 5.3 Elevators, Escalators, Conveyors: 5.4 Rubbish Chutes, Incinerators, and Laundry Chutes — N/A Sanford City Code — Chapter 9 Fire Sprinklers: Monitoring: N/A Other: NFPA 1 3-5.1 Fire Lanes — Not Required; 3-6.1 Key Box — Not Required; will field verify, see application 3-7.1 Bldg. Address Number Posted and Legible - Required; will field verify, SIX (6 ") in size contrasting in color (see blueprints) ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs EnergyGa uge FlaCom v 1.22 FORM 400A-2001, Whole BuildinS Perforinnnee Method for Commerc i al Ruild' --i!19s Jurisdiction: SANFORD, SEMINOLE COUNTY, FL (691500) Short Desc: SCALE HOUSE Project- SANFORD TRANhEk'- SCALE HOUSE Owner. Address: City- SANFORD, State: FLORIDA PerntitNo: Zip: 0 Type: Office (Business) Class: New Finished building Component Gross Energy Use Other Envelope Requirements - A Storeys: 2 GrossArea: 1923 Net Area: 1923 Max Tonnage: 3 (if different, write in) Compliance Summary Design 71.73 Criteria Result 100-00 PASSES PASSES LIGHTING CONTROLS PASSES EXTERNAL LIGHTING PASSES HVAC SYSTEM PASSE PLANT PASSES WATER HEATING SYSTEMS e;TASSES PIPING SYSTEMS PASSES Met all required compliance from Check List? J'Yei/No/NA NOTE: An input report Print -Out from EnergyGauge'HaComof L,IMPORTANT this design building must be submitted along with this Co ninc'e Report. EnergyGaugeflflCom FLCCSB v1.22 COMIPLIANCE CERTIFICATION: I I hereby certify that the plans and Review of the plans and specifications covered by this specifications covered by this calculation are calculation indicates compliance with the Florida Energy, in compliance ;with he F�Iorni Energy Code. Before construction is completed, this building will be inspected for compliance in accordance with Section Efficiency CodeI .- 553.9W, F.S. PREPARED ScFt ASSOC. ,INC. BUILDING OFFICIAL: 1:1Z1157 DATE: DATE: _Z PLANS -P insiurn— I hereby certify that this building is in waWbance CITY OF SAMFORD with the Florida Energy Eftiency Code. OWNER AGENT - DATE: If required by Florida law, I hereby car* that the system design is in REGISTRATION compliance with the Florida Energy Code. No. ARCHITECT: EARLS & ASSOC,INC. AR;3170--ID;00130 ELECTRICAL. .1 SYSTEM DESIGNER: EARLS & ASSOC INC. —AR: 3170--P.E.44631 . . .11 of 1: .. I 1, II 11 EuergyGauge FI#Com FLCCSBv1-22 Project: SCALE HOUSE Title: SANFORD TRANFER - SCALE HOUSE Type: Office (Business) Location: SANFORD, SEMINOLE COUNTY, FL (691500) _ (WEA File: Orlan Whole Building Compliance wf Design Reference } Total 71.73 100.00 ELECTRICITY 71.73 100.00 AREA LIGHTS 12.58 20.57 MISC EQUIPMT 4.88 4.88 PUMPS & MISC 0.14 0.14 SPACE COOL 16.61 33.85 VENT FANS 37.53 40.57 Credits & Penalties (if any): Modified Points: = 71.74 PASSES Project: SCALE HOUSE Title: SANFORD TRANFER - SCALE HOUSE Type: Office (Business) Location: SANFORD, SEMINOLE COUNTY, FL (691500) (WEA File: Orlan Other Envelope Requirements Item Zone Description Design Limit Meet Req. PrOZo2Rfl PrOZo2 Exterior Roof - Max Uo Limit 0.05 0.09 Yes PrOZo2RD PrOZo2 Exterior Roof - Max Uo Limit 0.05 0.09 Yes Meets Other Envelope Requirements r 11/12/04 EnergyGauge FlaCom FLCCSB 0.22 3 Project: SCALE HOUSE Title: SANFORD TRANFER - SCALE HOUSE Type: Office (Business) Location: SANFORD, SEMINOLE COUNTY, FL (691500) (WEA File: Orlan External Lighting Compliance Description Category Allowance Area or Length ELPA CLP (W/Unit) or No. of Units (W) (W) (Sgft or ft) Ext Light 1 Exit (with or without Canopy) 25.00 3.0 75 75 Ext Light 2 Exit (with or without Canopy) 25.00 3.0 75 75 Design: 150 (W) PASSES Allowance: 150 (W) Project: SCALE HOUSE Title: SANFORD TRANFER - SCALE HOUSE Type: Office (Business) Location: SANFORD, SEMINOLE COUNTY, FL (691500) (WEA File: Orlan Lighting Controls Compliance Acronym Ashrae Description Area No. of Design Min Compli- ED (sq.ft) Tasks CP CP ance PrOZoISp1 7 Food Service - Leisure Dining 464 1 2 2 PASSES PrOZo1Sp2 5 Electrical Mechanical Equipment 52 1 1 1 PASSES Room - Control Room PrOZo1Sp3 13 Toilet and Washroom 63 1 2 2 PASSES Pr0Zo1Sp4 25 Locker Room and Shower 115 1 2 2 PASSES PrOZoISp5 2 Corridor 85 1 1 1 PASSES Pr0Zo2Spl 26 Offices (Partitions>4.5 ft below 349 1 2 2 PASSES ceiling) Enclosed offices, all open plan offices without partitions PrOZo2Sp2 26 Offices (Partitions>4.5 ft below 269 1 2 2 PASSES ceiling) Enclosed offices, all open plan offices without partitions PrOZo2Sp3 26 Offices (Partitions>4.5 ft below 301 1 2 2 PASSES ceiling) Enclosed offices, all open plan offices without partitions PrOZo2Sp4 13 Toilet and Washroom 46 1 1 1 PASSES PASSES 11/12/04 EnergyGauge FlaCom FLCCSB v1.22 4 Project: SCALE HOUSE Title: SANFORD TRANFER - SCALE HOUSE Type: Office (Business) Location: SANFORD, SEMINOLE COUNTY, FL (691500) (WEA File: Orlan System Report Compliance PrOSyl System 1 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled < 65000 Btu/h Cooling Capacity 12.50 10.00 8.00 PASSES Air Handling Air Handler (Supply) - System -Supply Constant Volume 0.74 0.80 PASSES PrOSy2 System 2 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr i Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled < 65000 Btu/h Cooling Capacity 12.50 10.00 8.00 PASSES Air Handling Air Handler (Supply) - System -Supply Constant Volume 0.74 0.80 PASSES PASSES Plant Compliance Description Installed Size Design Min No Eff Eff Design Min Category Comp IPLV IPLV liance None 11/12/04 EnergyGauge FlaCom FLCCSB v1.22 5 Project: SCALE HOUSE Title: SANFORD TRANFER - SCALE HOUSE Type: Office (Business) Location: SANFORD, SEMINOLE COUNTY, FL (691500) (WEA File: Orlan Water Heater Compliance Description Type Category Design Eff Min Design Max Comp Eff Loss Loss liance Water Heater 1 Storage Water Heater - > 12 [kW] Electric 0.98 PASSES PASSES Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins Req Ins Complianc [inches] Runout? Temp [Btu-in/hr Thick [in] Thick [in] [F] .SF.F] None —� 11/12/04 EnergyGauge F1aCom FLCCSB v1.22 6 Project: SCALE HOUSE _ Title: SANFORD TRANFER - SCALE HOUSE Type: Office (Business) Location: SANFO - Other Required Compliance Category Section Requirement (write N/A in box if not applicable) Check Infiltration 406.1 Infiltration Criteria have been met ❑ System 407.1 RVAC Load sizing has been performed Ventilation 409.1 Ventilation criteria have been met ADS 410.1 Duct sizing and Design have been performed T & B 410.1 Testing and Balancing will be performed Electrical 413.1 Metering criteria have been met Motors 414.1 Motor efficiency criteria have been met Lighting 415.1 Lighting criteria have been met O & M 102.1 Operation/maintenance manual will be provided to owner Roof/Ceil 404.1 R-19 for Roof Deck with supply plenums beneath it Report 101 Input Report Print -Out from EnergyGauge F1aCom attached? 11/12/04 EnergyGauge FlaCom FLCCSB 0.22 7 ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs EnergyGauge F1aCom v1.22 INPUT DATA REPORT Project Information Project Name: SCALE HOUSE Project Title: - SANFORD TRANFER - SCALE HOUSE-- - Address: State: FLORIDA Zip: 0 Owner: Orientation: South Building Type: Office (Business) Building Classification: New Finished building No.of Storeys: 2 GrossArea: 1923 Zones No Acronym Description Type Load Profile Area Multiplier Total Area [sfl [sfl 1 PrOZol Zone 1 CONDITIONED Uses Building Load 958.4 1 958.4 Profile 2 PrOZo2 Zone 2 CONDITIONED Uses Building Load 965.0 1 965.0 Profile 11/12/04 EnergyGauge FlaCom FLCCSB v1.22 1 Spaces No Acronym Description Type Depth Width Height Multi Total Area Total Volume IN IN [ft] plier [sf] [cf] In Zone: PrOZol 1 PrOZo 1 Sp 1 ZoOSp 1 Food Service - Leisure 29.00 16.00 9.00 1 464.0 4176.0 Dining 2 PrOZolSp2 ZoOSp2 Electrical Mechanical 8.00 6.50 9.00 1 52.0 468.0 Equipment Room - Control Room 3 PrOZo1Sp3 ZoOSp3 Toilet and Washroom 8.00 7.91 9.00 2 126.6 1139.0 4 PrOZol Sp4 ZoOSp4 Locker Room and Shower 8.00 14.41 9.00 2 230.6 2075.0 5 PrOZo1Sp5 ZoOSp5 Corridor 16.00 5.33 9.00 1 85.3 767.5 El In Zone: PrOZo2 1 PrOZo2Spl ZoOSpl Offices (Partitions>4.5 ft 21.83 16.00 10.00 1 349.3 3492.8 El below ceiling) Enclosed offices, all open plan offices without partitions 2 PrOZo2Sp2 ZoOSp2 Offices (Partitions>4.5 ft 16.81 16.00 10.00 1 269.0 2689.6 El below ceiling) Enclosed offices, all open plan offices without partitions 3 PrOZo2Sp3 ZoOSp3 Offices (Partitions>4.5 ft 16.00 18.83 10.00 1 301.3 3012.8 below ceiling) Enclosed offices, all open plan offices without partitions 4 PrOZo2Sp4 ZoOSp4 Toilet and Washroom 6.50 7.00 10.00 1 45.5 455.0 Lighting No Type Power Control Type No.of [W] Ctrl pts In Zone: PrOZol In Space: PrOZo1Sp1 11/12/04 , EnergyGauge FlaCom FLCCSB v1.22 r, L 0 4 I Recessed Fluorescent - No vent 770.00 Occupancy sensor without 1 Daylighting In Space: Pr0Zo1Sp2 1 Suspended Fluorescent 74.00 Exception for One fixture or ballast 1 In Space: Pr0Zo1Sp3 1 Recessed Fluorescent - No vent 74.00 Exception for One fixture or ballast 1 ❑ In Space: Pr0Zo1Sp4 1 Recessed Fluorescent - No vent 110.00 Exception for One fixture or ballast 1 EJ In Space: Pr0Zo1Sp5 1 Recessed Fluorescent - No vent 110.00 Exception for One fixture or ballast 1 In Zone: PrOZo2 In Space: Pr0Zo2Sp1 1 Recessed Fluorescent - No vent 440.00 Occupancy sensor without 1 Daylighting In Space: PrOZo2Sp2 1 Recessed Fluorescent - No vent 330.00 Occupancy sensor without 1El Daylighting In Space: PrOZo2Sp3 1 Recessed Fluorescent - No vent 440.00 Occupancy sensor without 1 Daylighting In Space: PrOZo2Sp4 1 Recessed Fluorescent - No vent 74.00 Exception for One fixture or ballast 1 Walls No Description Type Width H (Effec) Multi Area DirectionConductance Heat Dens. R-Value [ft] [ft] plier [sf] [Btulhr. sf. F] Capacity [lb/cf] [h.sf.FBtu] [Btu/sf.F] In Zone: PrOZol 1 PrOZo1Wal Metal 60.00 12.00 1 720.0 North 0.0957 0.7570 16.80 10.45 siding/R1313att/0.5" Gyp 2 PrOZo1Wa2 Metal 16.00 12.00 1 192.0 East 0.0957 0.7570 16.80 10.45 siding/R 13Batt/0.5" Gyp 3 PrOZo 1 Wa3 Metal 60.00 12.00 1 720.0 South 0.0957 0.7570 16.80 10.45 siding/R 13 Batt/0.5" Gyp 11/12/04 EnergyGauge FlaCom FLCCSB v1.22 4 PrOZoIWa4 Metal 16.00 12.00 1 192.0 West 0.0957 0.7570 16.80 10.45 siding/R1313att/0.5" Gyp In Zone: PrOZo2 1 PrOZo2Wal Metal 60.00 12.00 1 720.0 North 0.0957 0.7570 16.80 10.45 siding/R 13 Batt/0.5" Gyp 2 PrOZo2Wa2 Metal 16.00 12.00 1 192.0 East 0.0957 0.7570 16.80 10.45 siding/R13Batt/0.5" Gyp 3 PrOZo2Wa3 Metal 60.00 12.00 1 720.0 South 0.0957 0.7570 16.80 10.45 siding/R 13Batt/0.5" Gyp 4 PrOZo2Wa4 Metal 16.00 12.00 1 192.0 West 0.0957 0.7570 16.80 10.45 siding/R 13Batt/0.5" Gyp Windows No Description Type Shaded UCen SC Vis.Tr W H (Effec) Multi Total Area [Btu/hr sf F] [ft] [ft] plier [S f] In Zone: PrOZol In Wall: PrOZo1Wal 1 PrOZolWalWil DOUBLE REF B No 0.6039 0.18 0.05 7.50 1.33 1 10.0 TINT-L IG In Wall: Pr0Zo1Wa2 1 PrOZol Wa2Wil DOUBLE REF B No 0.6039 0.18 0.05 5.00 4.00 1 20.0 El TINT-L IG In Wall: Pr0Zo1Wa3 1 PrOZoI Wa3WiI DOUBLE REF B Yes 0.6039 0.18 0.05 7.50 1.33 1 10.0 TINT-L IG 2 PrOZo1Wa3Wi2 DOUBLE REF B Yes 0.6039 0.18 0.05 3.00 6.67 1 20.0 TINT-L IG 3 PrOZo1Wa3Wi3 DOUBLE REF B Yes 0.6039 0.18 0.05 5.00 4.00 1 20.0 TINT-L IG 4 PrOZo1Wa3Wi4 DOUBLE REF B Yes 0.6039 0.18 0.05 5.00 4.00 1 20.0 TINT-L IG 11/12/04 EnergyGauge FlaCom FLCCSB v1.22 In Zone: PrOZo2 In Wall: PrOZo2Wa1 1 PrOZo2%l Wil DOUBLE REF B No 0.6039 0.18 0.05 5.00 4.00 5 100.0 ❑ TINT-L IG 2 Pr0Zo2Wa1Wi2 DOUBLE REF B No 0.6039 0.18 0.05 2.16 3.16 1 6.8 ❑ TINT-L IG In Wall: Pr0Zo2Wa2 1 PrOZo2Wa2Wil DOUBLE REF B No 0.6039 0.18 0.05 5.00 4.00 2 40.0 TINT-L IG In Wall: PrOZo2Wa3 1 PrOZo2%3WO DOUBLE REF B Yes 0.6039 0.18 0.05 5.00 4.00 1 20.0 TINT-L IG 2 PrOZo2Wa3Wi2 DOUBLE REF B Yes 0.6039 0.18 0.05 5.00 3.50 1 17.5 TINT-L IG 3 PrOZo2Wa3Wi3 DOUBLE REF B Yes 0.6039 0.18 0.05 5.00 4.00 1 20.0 ❑ TINT-L IG 4 PrOZo2Wa3Wi4 DOUBLE REF B Yes 0.6039 0.18 0.05 3.00 6.67 1 20.0 El TINT-L IG 5 PrOZo2Wa3Wi5 DOUBLE REF B Yes 0.6039 0.18 0.05 5.00 4.00 1 20.0 El TINT-L IG 6 PrOZo2Wa3Wi6 DOUBLE REF B Yes 0.6039 0.18 0.05 5.00 4.00 1 20.0 TINT-L IG In Wall: PrOZo2Wa4 1 Pr0Zo2Wa4Wi1 DOUBLE REF B No 0.6039 0.18 0.05 5.00 4.00 2 40.0 TINT-L IG Doors No Description Type Shaded? Width H (Effec) Multi Area Cond. Dens. Heat Cap. R-Value IN [ft] plier [sf] [Btu/hr. sf. F] [lb/cf] [Btu/sf. F] [h.sf.F/Btu] In Zone: In Wall: Roofs No Description Type Width H (Effec) Multi Area Tilt Cond. Heat Cap Dens. R-Value [ft] [ft] plier [sf] [deg] [Btu/hr. SE F] [Btu/sf. F] [lb/cf] [h.sf.F/Btu] 11/12/04 EnergyGauge FlaCom FLCCSB v1.22 In Zone: PrOZo2 1 PrOZo2Rfl Mtl Bldg Roof/R-19 8.00 60.00 1 480.0 5.00 0.0492 1.34 9.49 20.34 ❑ Batt 2 PrOZo2Rf2 Mtl Bldg Roof/R-19 8.00 60.00 1 480.0 5.00 0.0492 1.34 9.49 20.34 ❑ Batt Skylights No Description Type UCen Shading Vis.Trans W H (Effec) Multiplier Area Total Area [Btu/hr sf F] Coeff IN IN (sf] [Sf] In Zone: In Roof: El Floors No Description Type Width H (Effec) Multi Area Cond. Heat Cap. Dens. R-Value IN [ft] plier [sf] [Btu/hr. sf. F] [Btu/sf. F] [lb/cf] [h.sf.F/Btu] In Zone: PrOZol 1 PrOZo1F11 Concrete floor, 16.00 60.00 1 960.0 0.5987 9.33 140.00 1.67 ❑ carpet and rubber pad Systems PrOSyl System 1 Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System (Air Cooled < 65000 Btu/h Cooling Capacity) 2 Air Handling System -Supply (Air Handler (Supply) - Constant Volume) 36000.00 12.50 8.00 ❑ 1200.00 0.74 ❑ 11/12/04 EnergyGauge FlaCom FLCCSB v1.22 6 PrOSy2 System 2 Constant Volume Air Cooled Split System < 65000 Btu/hr No. Of Units 1 Component Category Capacity Efficiency IPLV I Cooling System (Air Cooled < 65000 Btu/h Cooling Capacity) 2 Air Handling System -Supply (Air Handler (Supply) - Constant Volume) 36000.00 12.50 8.00 1200.00 0.74 ❑ ❑ Plant Equipment Category Size Inst.No Eff. IPLV Water Heaters W-Heater Description Capacit Cap.Unit UP Rt. Efficienc Loss 1 Storage Water Heater - Electric 40 Gal 4500 [kW] [EF] [%/hr] ❑ Ext-Lighting Description Categories. Area/Len/No. of units [sf/ft/No] Wattage [W] 1 Ext Light 1 2 Ext Light 2 Exit (with or without Canopy) Exit (with or without Canopy) 3.00 3.00 75.00 75.00 ❑ ❑ Piping No Type Operating Insulation Temperature Conductivity [F] ( Btu-in/h.sf.F] Nomonal pipe Diameter [in] Insulation Is Runout? Thickness [in] 11/d2/04 EnergyGauge F1aCom FLCCSB v1.22 Fenestration Used Name Glass Type No. of Glass SC VLT Frame Frame Panes Conductance Conductance Absorptance [Btu/h.sf.F] [Btu/h.sf.F] ApLbWnd9 DOUBLE REF B 2 0.6039 0.1800 0.0450 0.4340 0.7000 ❑ TINT-L IG Materials Used Mat No Acronym Description Only R-Value RValue Thickness Conductivity Density SpecificHeat Used [h.sf.FBtu] IN [Btu/h.ft.F] [lb/cf] [Btu/lb.F] 18 Mat118 2 in. Wood No 2.3857 0.1670 0.0700 37.00 0.3900 ❑ 264 Mat1264 ALUMINUM, 1/16IN No 0.0002 0.0050 26.0000 480.00 0.1000 ❑ 214 Mat1214 POLYSTYRENE, EXP., No 5.2100 0.1042 0.0200 1.80 0.2900 ❑ 1-1/4IN, 187 Matll87 GYP OR PLAS No 0.4533 0.0417 0.0920 50.00 0.2000 ❑ B OARD,1 /2IN 206 Mat1206 CELLULOSE,FILL,5.5IN,R- No 20.8318 0.4583 0.0220 3.00 0.3300 ❑ 20 151 Matll51 CONC HW, DRD, 140LB, No 0.4403 0.3333 0.7570 140.00 0.2000 ❑ 41N 178 Mat1178 CARPET W/RUBBER PAD Yes 1.2300 ❑ 265 Mat1265 Soil, 1 ft No 2.0000 1.0000 0.5000 100.00 0.2000 ❑ 48 Mat148 6 in. Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000 ❑ 123 Mat1123 CONC BLOCK No 1.7227 0.6667 0.3870 53.00 0.2000 ❑ MW,8IN,HOLLOW 159 Mat1159 CONC No 0.3202 0.3333 1.0410 140.00 0.2000 ❑ HW-UNDRD-140LB-41N 57 Mat157 3/4 in. Plaster or gypsum No 0.1488 0.0625 0.4200 100.00 0.2000 ❑ 72 Mat172 AIR LAYER, 3/41N OR Yes 0.9000 ❑ LESS, VERT. WALLS 267 Mat1267 0.75" stucco No 0.1563 0.0625 0.4000 16.00 0.2000 ❑ 11/.12/04 , , A EnergyGauge FlaCom FLCCSB v1.22 8 266 Mat1266 2x4@16" oc + RI 1 Batt No 8.3343 0.2917 0.0350 9.70 0.2000 ❑ 215 Mat1215 POLYSTYRENE, EXP., No 8.3350 0.1667 0.0200 1.80 0.2900 ❑ 21N, 105 Matl105 CONC BLK HW, 8IN, No 1.1002 0.6667 0.6060 69.00 0.2000 ❑ HOLLOW 256 Mat1256 WOOD, SOFT, 1-1/21N No 1.8939 0.1250 0.0660 32.00 0.3300 ❑ 268 Mat1268 0.625" stucco No 0.1302 0.0521 0.4000 16.00 0.2000 ❑ 42 Mat142 8 in. Lightweight concrete No 2.0212 0.6670 0.3300 38.00 0.2000 ❑ block 269 Mat1269 .75" ISO BTWN24" oc No 2.2321 0.0625 0.0280 4.19 0.3000 ❑ 86 Mat186 BRICK, COMMON, 41N No 0.8012 0.3333 0.4160 120.00 0.2000 ❑ 211 Mat1211 POLYSTYRENE,EXP.,1/2I No 2.0850 0.0417 0.0200 1.80 0.2900 ❑ N, 12 Matl12 3 in. Insulation No 10.0000 0.2500 0.0250 2.00 0.2000 ❑ 218 Mat1218 POLYURETHANE,EXP.,1/2 No 3.2077 0.0417 0.0130 1.50 0.3800 ❑ IN, 23 Mat123 6 in. Insulation No 20.0000 0.5000 0.0250 5.70 0.2000 ❑ 4 Mat14 Steel siding No 0.0002 0.0050 26.0000 480.00 0.1000 ❑ 271 Mat1271 2x4@24" oc + RI 1 Batt No 10.4179 0.2917 0.0280 7.11 0.2000 ❑ 272 Mat1272 Panel with 7/16" panels Yes 0.9044 ❑ 273 Mat1273 Hollow core flush (1.375") Yes 1.2777 ❑ 274 Mat1274 Solid core flush (1.375") Yes 1.7141 ❑ 275 Mat1275 Panel with 7/16" panels Yes 1.0019 ❑ (1.375") 276 Mat1276 Hollow core flush (1.75") Yes 1.3239 ❑ 277 Mat1277 Panel with 1-1/8" panels Yes 1.7141 ❑ (1.75") 278 Mat1278 Solid core flush (1.75") Yes 1.6500 ❑ 279 Mat1279 Solid core flush (2.25") Yes 2.8537 ❑ 280 Mat1280 Fiberglass/Mineral wool core Yes 0.8167 ❑ 281 Mat1281 Paper Honeycomb core Yes 0.9357 ❑ 282 Mat1282 Solid Urethane foam core Yes 1.6500 ❑ 283 Mat1283 Solid mineral fiberboard core Yes 1.7816 ❑ 284 Mat1284 Polystyrene core (18 ga steel) Yes 2.0071 ❑ 1 285 Mat1285 Polyurethane core (18 ga Yes 2.5983 ❑ steel) 2 286 Mat1286 Polyurethane core (24 ga Yes 2.5983 ❑ steel) I 11/42/04 EnergyGauge FlaCom FLCCSB v1.22 9 287 Mat1287 Polyurethane core (24 ga Yes 4.1500 ❑ steel) 2 288 Mat1288 Solid Urethane foam core Yes 4.1500 ❑ 81 Mat181 ASPHALT -ROOFING, Yes 0.1500 ❑ ROLL 244 Mat1244 PLYWOOD, 1/21N No 0.6318 0.0417 0.0660 34.00 0.2900 ❑ 185 Matl185 CLAY TILE, PAVER, 3/81N No 0.0301 0.0313 1.0410 120.00 0.2000 ❑ 82 Mat182 ASPHALT -SHINGLE AND Yes 0.4400 ❑ SIDING 11 Mat111 2 in. Insulation No 6.6800 0.1670 0.0250 2.00 0.2000 ❑ 47 Mat147 2 in. Heavyweight concrete No 0.1670 0.1670 1.0000 140.00 0.2000 ❑ 95 Mat195 CONC BLOCK No 0.7107 0.3333 0.4690 101.00 0.2000 ❑ HW-4IN-HOLLOW 248 Mat1248 ROOF GRAVEL OR No 0.0500 0.0417 0.8340 55.00 0.4000 ❑ SLAG 1 /2IN 94 Mat194 BUILT-UP ROOFING, No 0.3366 0.0313 0.0930 70.00 0.3500 ❑ 3/81N Constructs Used No Name Simple Massless Conductance Construct Construct [Btu/h.sf.F] 1004 Concrete floor, carpet and rubber pad No No 0.60 Layer Material Material Thickness No. IN 1 151 CONC HW, DRD, 140LB, 41N 0.3333 2 178 CARPET W/RUBBER PAD e 11/12/04 EnergyGauge F1aCom FLCCSB v1.22 Heat Capacity Density RValue [Btu/sf.F] [lb/cf] [h.sf.FBtu] 9.33 140.00 1.6703 ❑ Framing Factor 0.00 0.00 10 No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [!b/cf] [h.sf.F/Btu] 1020 Metal siding/R13Batt/0.5"Gyp No No 0.10 0.76 16.80 10.4535 ❑ Layer Material Material Thickness Framing No. IN Factor 1 4 Steel siding 0.0050 0.00 ❑ 2 12 - 3 in. Insulation 0.2500 0.00 ❑ 3 187 GYP OR PLAS BOARD,1/21N 0.0417 0.00 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.F/Btu] 1047 Mtl Bldg Roof/R-19 Batt No No 0.05 1.34 9.49 20.3366 ❑ Layer Material Material Thickness Framing No. IN Factor 1 94 BUILT-UP ROOFING, 3/81N 0.0313 0.00 ❑ 2 23 6 in. Insulation 0.5000 0.00 ❑ 11/12/04 EnergyGauge FlaCom FLCCSB v1.22 11 SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, FI. 32772 (407 302-2520 I FAX (407) 302-2526 Plans Review Sheet Date: December 8 2004 Business Address: 555 N. White Cedar Road Occur. Ch.38 Business Business Name: Sanford Recycling Contractor: Mc Kee Construction Reviewed [ Ph. () FAX () Ph. (407) 323-1150 FAX (407)323-9304 Rejected [ Reviewed by: Timothy Robles, Fire Protection Inspector/plans Examiner Comment: Plans reviewed as Business Occupancy. FD reserves right to require applicable code requirements if occupancy use changes. 1,920 sq ft building 1.1 Application —New Building. 1.2 Mixed — N/A 1.3 Special Definitions — Meets F.F.P.C. - 6.1.11.1 (Record keeping/Business transactions). 1.4Classification of Occupancy — Business F.F.P. C. 1.5 Classification of Hazard of Contents — Ordinary/6.2.2.2. 1.6 Minimum Construction — N/R 2.2 Means of Egress Components — O.K. 2.3 Capacity of Egress — One person per 100 sq ft (50 or more occupants shall comply with 44' isle ways 2.4 Number of Exits — O.K. two remote exits (less than 75' ft OK) 2.5 Arrangement of Egress — O.K., will field verify 2.6 Travel Distance — O.K. 1 SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, FI. 32772 (407 302-2520 / FAX (407) 302-2526 2.7 Discharge from Exits — O.K., will field verify 2.8 Illumination of Means of Egress — O.K.; will field verify 2.9 Emergency Lighting — O.K.; will field verify 2.10 Marking of Means of Egress — O.K.; will field verify? 2.11 Special Features — 3.1 Protection of Vertical Openings — 3.2 Protection from Hazards — N/N 3.3 Interior Finish - Class "A " 3.4 Detection, Alarm and Communications Systems —Not Required 3.5 Extinguishing Requirements — as per NFPA 10 — Two (2) 3A rated fire extinguishers required in this building mounted at 36" from floor to bottom see blue prints 3.6 Corridors — 4 Special Provisions - 5 Building Services 5.1 Utilities — 5.2 HVAC — 5.3 Elevators, Escalators, Conveyors: 5.4 Rubbish Chutes, Incinerators, and Laundry Chutes — N/A Sanford City Code — Chapter 9 Fire Sprinklers: Monitoring: N/A Other: NFPA 1 3-5.1 Fire Lanes — Not Required; 3-6.1 Key Box — Not Required; will field verify, see application 3-7.1 Bldg. Address Number Posted and Legible - Required; will field verify, SIX (6') in size contrasting in color (see blueprints) 2 r- - i ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs EnergyGauge FlaCom v1.22 FORM 40OA-2001 Whole Building Performance Method for Commercial Buildin s Jurisdiction: SANFORD, SEMINOLE COUNTY, FL (691500) Short Desc: SCALE HOUSE Project: SANFORD TRANFER - SCALE HOUSE Owner: Address: City: SANFORD State: FLORIDA Zip: 0 Type: Office (Business) Class: New Finished building PermitNo: Storeys: 2 GrossArea: 1923 Net Area: 1923 Max Tonnage: 3 (if different, write in) Compliance Summary Component Design Criteria Result Gross Energy Use 71.73 100.00 PASSES Other Envelope Requirements - A PASSES LIGHTING CONTROLS EXTERNAL LIGHTING HVAC SYSTEM PLANT WATER HEATING SYSTEMS PIPING SYSTEMS Met all required compliance from Check List? PASSES PASSES PASSES PASSES PASSES PASSES Yes/No/NA IMPORTANT NOTE: An input report Print -Out from EnergyGauge FlaCom of this design building must be submitted along with this Compliance Report. 11/12/04 EnergyGauge FlaCom FLCCSB v1.22 1 T COMPLIANCE CFRILEICATION: I hereby certify that the plans and specifications covered this cal c4ilation are in compliance w' F Energy - Efficiency Code. PREPARED B ASSOC.,INC. DATE: I hereby certify that this is in oompliartce with the Florida Energy Efficiency Code. OWNER AGENT - DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed, this building will be inspected for compliance in accordance with Section 553.908, F.S. BUILDING OFFICIAL: DATE: .Q, Project: SCALE HOUSE Title: SANFORD TRANFER - SCALE HOUSE Type: Office (Business) Location: SANFORD, SEMINOLE COUNTY, FL (691500) (WEA File: Orlan Total Whole Building Compliance Design 71.73 Reference 100.00 ELECTRICITY 71.73 100.00 AREA LIGHTS 12.58 20.57 MISC EQUIPMT 4.88 4.88 PUMPS & MISC 0.14 0.14 SPACE COOL 16.61 33.85 VENT FANS 37.53 40.57 Credits & Penalties (if any): Modified Points: = 71.74 PASSES Project: SCALE HOUSE Title: SANFORD TRANFER - SCALE HOUSE Type: Office (Business) Location: SANFORD, SEMINOLE COUNTY, FL (691500) (WEA File: Orlan Other Envelope Requirements Item Zone Description Design Limit Meet Req. Pr0Zo2Rfl PrOZo2 Exterior Roof - Max Uo Limit 0.05 0.09 Yes PrOZo2Rf2 PrOZo2 Exterior Roof - Max Uo Limit 0.05 0.09 Yes Meets Other Envelope Requirements 11/12/04 EnergyGauge FlaCom FLCCSB v1.22 3 Sw Project: SCALE HOUSE Title: SANFORD TRANFER - SCALE HOUSE Type: Office (Business) Location: SANFORD, SEMINOLE COUNTY, FL (691500) (WEA File: Orlan External Lighting Compliance Description Category Allowance Area or Length ELPA CLP (W/Unit) or No. of Units (W) (W) (Sgft or ft) Ext Light 1 Exit (with or without Canopy) 25.00 3.0 75 75 Ext Light 2 Exit (with or without Canopy) 25.00 3.0 75 75 Design: 150 (W) PASSES Allowance: 150 (W) Project: SCALE HOUSE Title: SANFORD TRANFER - SCALE HOUSE Type: Office (Business) Location: SANFORD, SEMINOLE COUNTY, FL (691500) (WEA File: Orlan Lighting Controls Compliance Acronym Ashrae Description Area No. of Design Min Compli- ID (sq.ft) Tasks CP CP ance PrOZo 1 Sp 1 7 Food Service - Leisure Dining 464 1 2 2 PASSES PrOZoISp2 5 Electrical Mechanical Equipment 52 1 1 1 PASSES Room - Control Room PrOZolSp3 13 Toilet and Washroom 63 1 2 2 PASSES PrOZo 1 Sp4 25 Locker Room and Shower 115 1 2 2 PASSES PrOZo1Sp5 2 Corridor 85 1 1 1 PASSES Pr0Zo2Sp1 26 Offices (Partitions>4.5 ft below 349 1 2 2 PASSES ceiling) Enclosed offices, all open plan offices without partitions PrOZo2Sp2 26 Offices (Partitions>4.5 ft below 269 1 2 2 PASSES ceiling) Enclosed offices, all open plan offices without partitions PrOZo2Sp3 26 Offices (Partitions>4.5 ft below 301 1 2 2 PASSES ceiling) Enclosed offices, all open plan offices without partitions PrOZo2Sp4 13 Toilet and Washroom 46 1 1 1 PASSES PASSES 11/12/04 EnergyGauge FlaCom FLCCSB v1.22 Project: SCALE HOUSE Title: SANFORD TRANFER - SCALE HOUSE Type: Office (Business) Location: SANFORD, SEMINOLE COUNTY, FL (691500) (WEA File: Orlan System Report Compliance PrOSyl System 1 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled < 65000 Btu/h Cooling Capacity 12.50 10.00 8.00 PASSES Air Handling Air Handler (Supply) - System -Supply Constant Volume 0.74 0.80 PASSES PrOSy2 System 2 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled < 65000 Btu/h Cooling Capacity 12.50 10.00 8.00 PASSES Air Handling Air Handler (Supply) - System -Supply Constant Volume 0.74 0.80 PASSES PASSES Plant Compliance Description Installed Size Design Min No Eff Eff Design Min Category Comp IPLV IPLV liance None l 1/12/04 EnergyGauge FlaCom FLCCSB v1.22 Project: SCALE HOUSE Title: SANFORD TRANFER - SCALE HOUSE Type: Office (Business) Location: SANFORD, SEMINOLE COUNTY, FL (691500) (WEA File: Orlan Water Beater Compliance Description Type Category Design Eff Min Design Max Comp Eff Loss Loss liance Water Heater 1 Storage Water Heater - > 12 [kW] Electric 0.98 PASSES PASSES Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins Req Ins Complianc [inches] Runout? Temp [Btu-in/hr Thick [in] Thick [in] [F] SF.F] None 11/12/04 EnergyGauge FlaCom FLCCSB v1.22 6 L-_ Project: SCALE HOUSE Title: SANFORD TRANFER - SCALE HOUSE Type: Office (Business) Location: SANFO Other Required Compliance Category Section Requirement (write N/A in box if not applicable) Check Infiltration 406.1 Infiltration Criteria have been met System 407.1 HVAC Load sizing has been performed Ventilation 409.1 Ventilation criteria have been met ADS 410.1 Duct sizing and Design have been performed T & B 410.1 Testing and Balancing will be performed Electrical 413.1 Metering criteria have been met Motors 414.1 Motor efficiency criteria have been met Lighting 415.1 Lighting criteria have been met O & M 102.1 Operation/maintenance manual will be provided to owner Roof/Ceil 404.1 R-19 for Roof Deck with supply plenums beneath it Report 101 Input Report Print -Out from EnergyGauge F1aCom attached? l 1/12/04 EnergyGauge F1aCom FLCCSB v1.22 7 ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs EnergyGauge FlaCom v1.22 INPUT DATA REPORT Proiect Information Project Name: SCALE HOUSE Orientation: South Project Title: SANFORD TRANFER - SCALE HOUSE Building Type: Office (Business) Address: Building Classification: New Finished building State: FLORIDA Zip: 0 Owner: No.of Storeys: 2 GrossArea: 1923 Zones No Acronym Description Type Load Profile Area Multiplier Total Area [sfl [sq 1 PrOZol Zone 1 CONDITIONED Uses Building Load 958.4 1 958.4 ❑ Profile 2 PrOZo2 Zone 2 CONDITIONED Uses Building Load 965.0 1 . 965.0 ❑ Profile 11/12/04 EnergyGauge FlaCom FLCCSB v1.22 1 Spaces No Acronym Description Type Depth Width Height . Multi Total Area Total Volume IN [ft] [ft] plier [sf] [cfJ In Zone: PrOZol 1 PrOZo1Spl ZoOSpl Food Service - Leisure 29.00 16.00 9.00 1 464.0 4176.0 ❑ Dining 2 PrOZo 1 Sp2 ZoOSp2 Electrical Mechanical 8.00 6.50 9.00 1 52.0 468.0 El Equipment Room - Control Room 3 PrOZo1Sp3 ZoOSp3 Toilet and Washroom 8.00 7.91 9.00 2 126.6 1139.0 4 PrOZo1Sp4 ZoOSp4 Locker Room and Shower 8.00 14.41 9.00 2 230.6 2075.0 5 PrOZo1Sp5 ZoOSp5 Corridor 16.00 5.33 9.00 1 85.3 767.5 El In Zone: PrOZo2 1 PrOZo2Sp1 Zo0Sp1 Offices (Partitions>4.5 ft 21.83 16.00 10.00 1 349.3 3492.8 below ceiling) Enclosed offices, all open plan offices without partitions 2 PrOZo2Sp2 ZoOSp2 Offices (Partitions>4.5 ft 16.81 16.00 10.00 1 269.0 2689.6 El below ceiling) Enclosed offices, all open plan offices without partitions 3 PrOZo2Sp3 ZoOSp3 Offices (Partitions>4.5 ft 16.00 18.83 10.00 1 301.3 3012.8 El below ceiling) Enclosed offices, all open plan offices without partitions 4 PrOZo2Sp4 ZoOSp4 Toilet and Washroom 6.50 7.00 10.00 1 45.5 455.0 Lighting No Type Power Control Type No.of [W] Ctrl pts In Zone: PrOZol In Space: PrOZo1Sp1 11/12/04 EnergyGauge FlaCom FLCCSB v1.22 I Recessed Fluorescent - No vent 770.00 Occupancy sensor without 1El Daylighting In Space: Pr0Zo1Sp2 1 Suspended Fluorescent 74.00 Exception for One fixture or ballast 1 [] In Space: Pr0Zo1.Sp3 1 Recessed Fluorescent - No vent 74.00 Exception for One fixture or ballast 1 In Space: Pr0Zo1Sp4 1 Recessed Fluorescent - No vent 110.00 Exception for One fixture or ballast 1 In Space: Pr0Zo1Sp5 1 Recessed Fluorescent - No vent 110.00 Exception for One fixture or ballast 1 In Zone: PrOZo2 In Space: Pr0Zo2Sp1 1 Recessed Fluorescent - No vent 440.00 Occupancy sensor without 1 Daylighting In Space: PrOZo2Sp2 1 Recessed Fluorescent - No vent 330.00 Occupancy sensor without 1 Daylighting In Space: PrOZo2Sp3 1 Recessed Fluorescent - No vent 440.00 Occupancy sensor without 1El Daylighting In Space: PrOZo2Sp4 1 Recessed Fluorescent - No vent 74.00 Exception for One fixture or ballast 1 Walls No Description Type Width H (Effec) Multi Area DirectionConductance Heat Dens. R-Value IN [ft] plier [sf] [Btu/hr. sf. F] Capacity [lb/cf] [h.sf.FBtu] [Btu/sf.F] In Zone: PrOZol 1 PrOZo 1 Wal Metal 60.00 12.00 1 720.0 North 0.0957 0.7570 16.80 10.45 siding/R1313att/0.5" Gyp 2 PrOZo1Wa2 Metal 16.00 12.00 1 192.0 East 0.0957 0.7570 16.80 10.45 siding/R13Batt/0.5" Gyp 3 PrOZo1Wa3 Metal 60.00 12.00 1 720.0 South 0.0957 0.7570 16.80 10.45 siding/R1313att/0.5" Gyp 11/12/04 EnergyGauge FlaCom FLCCSB 0.22 0 4 PrOZoIWa4 Metal 16.00 12.00 1 192.0 West 0.0957 0.7570 16.80 10.45 siding/R UBatt/0.5" Gyp In Zone: PrOZo2 1 PrOZo2Wal Metal 60.00 12.00 1 720.0 North 0.0957 0.7570 16.80 10.45 siding/RUBatt/0.5" Gyp 2 PrOZo2Wa2 Metal 16.00 12.00 1 192.0 East 0.0957 0.7570 16.80 10.45 siding/RDBatt/0.5" Gyp 3 PrOZo2Wa3 Metal 60.00 12.00 1 720.0 South 0.0957 0.7570 16.80 10.45 siding/RDBatt/0.5" Gyp 4 PrOZo2Wa4 Metal 16.00 12.00 1 192.0 West 0.0957 0.7570 16.80 10.45 siding/RDBatt/0.5" Gyp Windows No Description Type Shaded UCen SC Vis.Tr W H (Effec) Multi Total Area [Btu/hr sf F] IN [ft] plier [sf] In Zone: PrOZol In Wall: PrOZolWal 1 PrOZolWalWil DOUBLE REF B No 0.6039, 0.18 0.05 7.50 1.33 1 10.0 7 TINT-L IG In Wall: Pr0Zo1Wa2 1 PrOZo1Wa2Wil DOUBLE REF B No 0.6039 0.18 0.05 5.00 4.00 1 20.0 TINT-L IG In Wall: Pr0Zo1Wa3 1 PrOZo1Wa3Wil DOUBLE REF B Yes 0.6039 0.18 0.05 7.50 1.33 1 10.0 TINT-L IG 2 PrOZol Wa3Wi2 DOUBLE REF B Yes 0.6039 0.18 0.05 3.00 6.67 1 20.0 ED TINT-L IG 3 PrOZo1Wa3Wi3 DOUBLE REF B Yes 0.6039 0.18 0.05 5.00 4.00 1 20.0 TINT-L IG 4 PrOZo1Wa3Wi4 DOUBLE REF B Yes 0.6039 0.18 0.05 5.00 4.00 1 20.0 TINT-L IG 11/12/04 EnergyGauge FlaCom FLCCSB v1.22 In Zone: PrOZo2 In Wall: PrOZo2Wa1 1 PrOZo2Wal Wil DOUBLE REF B No 0.6039 0.18 0.05 5.00 4.00 5 100.0 TINT-L IG 2 Pr0Zo2Wa1Wi2 DOUBLE REF B No 0.6039 0.18 0.05 2.16 3.16 1 6.8 TINT-L IG In Wall: PrOZo2Wa2 1 PrOZo2Wa2Wil DOUBLE REF B No 0.6039 0.18 0.05 5.00 4.00 2 40.0 TINT-L IG In Wall: PrOZo2Wa3 1 PrOZo2%3Wil DOUBLE REF B Yes 0.6039 0.18 0.05 5.00 4.00 1 20.0 ❑ TINT-L IG 2 PrOZo2Wa3Wi2 DOUBLE REF B Yes 0.6039 0.18 0.05 5.00 3.50 1 17.5 ❑ TINT-L IG 3 PrOZo2Wa3Wi3 DOUBLE REF B Yes 0.6039 0.18 0.05 5.00 4.00 1 20.0 ❑ TINT-L IG 4 PrOZo2Wa3Wi4 DOUBLE REF B Yes 0.6039 0.18 0.05 3.00 6.67 1 20.0 ❑ TINT-L IG 5 PrOZo2Wa3Wi5 DOUBLE REF B Yes 0.6039 0.18 0.05 5.00 4.00 1 20.0 ❑ TINT-L IG 6 PrOZo2Wa3Wi6 DOUBLE REF B Yes 0.6039 0.18 0.05 5.00 4.00 1 20.0 TINT-L IG In Wall: PrOZo2Wa4 1 Pr0Zo2Wa4Wi1 DOUBLE REF B No 0.6039 0.18 0.05 5.00 4.00 2 40.0 TINT-L IG Doors No Description Type Shaded? Width H (Effec) Multi Area Cond. Dens. Heat Cap. R-Value IN [ft] plier [sf] [Btu/hr. sf. F] [lb/cf] [Btu/sf. F] [h.sf.F/Btu] In Zone: In Wall: Roofs No Description Type Width H (Effec) Multi Area Tilt Cond. Heat Cap Dens. R-Value IN IN plier [sf] [deg] [Btu/hr. Sf. F] [Btu/sf. F] [lb/cf] [h.sf.F/Btu] 11/12/04 EnergyGauge FlaCom FLCCSB v1.22 In Zone: PrOZo2 1 PrOZo2Rfl Mtl Bldg Roof/R-19 8.00 60.00 1 480.0 5.00 0.0492 1.34 9.49 20.34 ❑ Batt 2 PrOZo2Rf2 Mtl Bldg Roof/R-19 8.00 60.00 1 480.0 5.00 0.0492 1.34 9.49 20.34 ❑ Batt Skylights No Description Type UCen Shading Vis.Trans W H (Effec) Multiplier Area Total Area [Btu/hr sf F) Coeff IN IN [Sf) [Sf1 In Zone: In Roof: EJ Floors No Description Type Width H (Effec) Multi Area Cond. Heat Cap. Dens. R-Value [ft] [ft] plier [sf] [Btu/hr. sf. F] [Btu/sL F] [lb/cf] [h.sf.FBtu] In Zone: PrOZol 1 PrOZo 1 Fl1 Concrete floor, 16.00 60.00 1 960.0 0.5987 9.33 140.00 1.67 ❑ carpet and rubber pad Systems PrOSyl System 1 Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System (Air Cooled < 65000 Btu/h Cooling Capacity) 2 Air Handling System -Supply (Air Handler (Supply) - Constant Volume) 36000.00 12.50 8.00 ❑ 1200.00 0.74 ❑ 11/12/04 EnergyGauge FlaCom FLCCSB v1.22 PrOSy2 System 2 Constant Volume Air Cooled Split System < 65000 Btu/hr No. Of Units 1 Component Category Capacity Efficiency IPLV 1 Cooling System (Air Cooled < 65000 Btu/h Cooling Capacity) 2 Air Handling System -Supply (Air Handler (Supply) - Constant Volume) 36000.00 12.50 8.00 1200.00 0.74 ❑ ❑ Plant Equipment Category Size Inst.No Eff. IPLV Water Heaters W-Heater Description Capacit Cap.Unit I/P Rt. Efficienc Loss 1 Storage Water Heater - Electric 40 Gal 4500 [kW] [EF] [%/hr] ❑ Ext-Lighting Description Categories. Area/Len/No. of units [sf/ft/No] Wattage [W] 1 Ext Light 1 2 Ext Light 2 Exit (with or without Canopy) Exit (with or without Canopy) 3.00 3.00 75.00 75.00 ❑ ❑ Piping No Type Operating Insulation Temperature Conductivity [F] [ Btu-in/h.sf.F] Nomonal pipe Diameter [in] Insulation Thickness [in] Is Runout? 11/12/04 EnergyGauge FlaCom FLCCSB v1.22 Fenestration Used Name Glass Type No. of Glass SC VI.T Frame Frame Panes Conductance Conductance. Absorptance [Btu/h.sf.F] [Btu/h.sf.F] ApLbWnd9 DOUBLE REF B 2 0.6039 0.1800 0.0450 0.4340 0.7000 ❑ TINT-L IG Materials Used Mat No Acronym Description Only R-Value RValue Thickness Conductivity Density SpecificHeat Used [h.sf.FBtu] IN [Btu/h.ft.F] [lb/cf] [Btu/1b.F] 18 Mad18 2 in. Wood No 2.3857 0.1670 0.0700. 37.00 0.3900 ❑ 264 Mat1264 ALUMINUM, 1/16IN No 0.0002 0.0050 26.0000 480.00 0.1000 ❑' 214 Mat1214 POLYSTYRENE, EXP., No 5.2100 0.1042 0.0200 1.80 0.2900 ❑ 1-1 /4IN, 187 Mat1187 GYP OR PLAS No 0.4533 0.0417 0.0920 50.00 0.2000 ❑ B OARD,1 /2IN 206 Mat1206 CELLULOSE,FILL,5.5IN,R- No 20.8318 0.4583 0.0220 3.00 0.3300 ❑ 20 151 Matll51 CONC HW, DRD, 140LB, No 0.4403 0.3333 0.7570 140.00 0.2000 ❑ 41N 178 Mat1178 CARPET W/RUBBER PAD Yes 1.2300 ❑ 265 Mat1265 Soil, 1 ft No 2.0000 1.0000 0.5000 100.00 0.2000 ❑ 48 Mat148 6 in. Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000 ❑ 123 Mat1123 CONC BLOCK No 1.7227 0.6667 0.3870 53.00 0.2000 ❑ MW,8IN,HOLLOW 159 Mat1159 CONC No 0.3202 0.3333 1.0410 140.00 0.2000 ❑ HW-UNDRD-140LB-41N 57 Mat157 3/4 in. Plaster or gypsum No 0.1488 0.0625 0.4200 100.00 0.2000 ❑ 72 Mat172 AIR LAYER, 3/41N OR Yes 0.9000 ❑ LESS, VERT. WALLS 267 Mat1267 0.75" stucco No 0.1563 0.0625 0.4000 16.00 0.2000 ❑ 11/12/04 EnergyGauge F1aCom FLCCSB v1.22 8 4" 266 Mat1266 2x4@ 16" oc + RI Batt No 8.3343 0.2917 0.0350 9.70 0.2000 ❑ 215 Mat1215 POLYSTYRENE, EXP., No 8.3350 0.1667 0.0200 1.80 0.2900 ❑ 2IN, 105 Matl105 CONC BLK HW, 8IN, No 1.1002 0.6667 0.6060 69.00 0.2000 ❑ HOLLOW ' 256 Mat1256 WOOD, SOFT, 1-1/21N No 1.8939 0.1250 0.0660 32.00 0.3300 ❑ 268 Mat1268 0.625" stucco No 0.1302 0.0521 0.4000 16.00 0.2000 ❑ 42 Mat142 8 in. Lightweight concrete No 2.0212 0.6670 0.3300 38.00 0.2000 ❑ block 269 Mat1269 .75" ISO BTWN24" oc No 2.2321 0.0625 0.0280 4.19 0.3000 ❑ 86 Mat186 BRICK, COMMON, 41N No 0.8012 0.3333 0.4160 120.00 0.2000 ❑ 211 Matl211 POLYSTYRENE,EXP.,1/2I No 2.0850 0.0417 0.0200 1.80 0.2900 ❑ N, 12 Mat112 3 in. Insulation No 10.0000 0.2500 0.0250 2.00 0.2000 ❑ 218 Mat1218 POLYURETHANE,EXP.,1/2 No 3.2077 0.0417 0.0130 1.50 0.3800 ❑ IN, 23 Mat123 6 in. Insulation No 20.0000 0.5000 0.0250 5.70 0.2000 ❑ 4 Mat14 Steel siding No 0.0002 0.0050 26.0000 480.00 0.1000 ❑ 271 Mat1271 2x4@24" oc + Rl 1 Batt No 10.4179 0.2917 0.0280 7.11 0.2000 ❑ 272 Mat1272 Panel with 7/16" panels Yes 0.9044 ❑ 273 Mat1273 Hollow core flush (1.375") Yes 1.2777 ❑ 274 Mat1274 Solid core flush (1.375") Yes 1.7141 ❑ 275 Mat1275 Panel with 7/16" panels Yes 1.0019 ❑ (1.375") 276 Mat1276 Hollow core flush (1.75") Yes 1.3239 ❑ 277 Mat1277 Panel with 1-1/8" panels Yes 1.7141 ❑ (1.75" ) 278 Mat1278 Solid core flush (1.75") Yes 1.6500 ❑ 279 Mat1279 Solid core flush (2.25") Yes 2.8537 ❑ 280 Mat1280 Fiberglass/Mineral wool core Yes 0.8.167 ❑ 281 Mat1281 Paper Honeycomb core Yes 0.9357 ❑ 282 Mat1282 Solid Urethane foam core Yes 1.6500 ❑ 283 Mat1283 Solid mineral fiberboard core Yes 1.7816 ❑ 284 Mat1284 Polystyrene core (18 ga steel) Yes 2.0071 ❑ 1 285 Mat1285 Polyurethane core (18 ga Yes 2.5983 ❑ steel) 2 286 Mat1286 Polyurethane core (24 ga Yes 2.5983 ❑ steel) 1 11/12/04 EnergyGauge FlaCom FLCCSB v1.22 9 ca. 287 Mat1287 Polyurethane core (24 ga Yes 4.1500 ❑ steel) 2 288 Mat1288 Solid Urethane foam core Yes 4.1500 ❑ 81 Matl81 ASPHALT -ROOFING, Yes 0.1500 ❑ ROLL 244 Mat1244 PLYWOOD, 1/21N No 0.6318 0.0417 0.0660 34.00 0.2900 ❑ 185 Mat1185 CLAY TILE, PAVER, 3/81N No 0.0301 0.0313 1.0410 120.00 0.2000 ❑ 82 Mat182 ASPHALT -SHINGLE AND Yes 0.4400 ❑ SIDING 11 Mad11 2 in. Insulation No 6.6800 0.1670 0.0250 2.00 0.2000 ❑ 47 Mat147 2 in. Heavyweight concrete No 0.1670 0.1670 1.0000 140.00 0.2000 ❑ 95 Mat195 CONC BLOCK No 0.7107 0.3333 0.4690 101.00 0.2000 ❑ HW-4IN-HOLLOW 248 Mat1248 ROOF GRAVEL OR No 0.0500 0.0417 0.8340 55.00 0.4000 ❑ SLAG 1/2IN 94 Mat194 BUILT-UP ROOFING, No 0.3366 0.0313 0.0930 70.00 0.3500 ❑ 3/8IN Constructs Used No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.F/Btu] 1004 Concrete floor, carpet and rubber pad No No 0.60 9.33 140.00 1.6703 ❑ Layer Material Material Thickness Framing No. IN Factor 1 151 CONC HW, DRD, 140LB, 41N 0.3333 0.00 ❑ 2 178 CARPET W/RUBBER PAD 0.00 ❑ 11/12/04 EnergyGauge FlaCom FLCCSB v1.22 10 No Name Simple Construct Massless Conductance Construct [Btu/h.sf.F] 1020 Metal siding/R I 3Batt/0.5 "Gyp No No 0.10 Layer Material Material Thickness No. IN 1 4 Steel siding 0.0050 2 12 ` 3 in. Insulation 0.2500 3 187 GYP OR PLAS BOARD,1/21N 0.0417 No Name Simple Construct Massless Conductance Construct [Btu/h.sf.F] 1047 Mtl Bldg Roof/R-19 Batt No No 0.05 Layer Material Material Thickness No. IN 1 94 BUILT-UP ROOFING, 3/81N 0.0313 2 23 6 in. Insulation 0.5000 Heat Capacity Density RValue [Btu/sf.F] [lb/cf] [h.sf.F/Btu] 0.76 16.80 10.4535 ❑ Framing Factor 0.00 ❑ 0.00 El 0.00 ❑ Heat Capacity Density RValue [Btu/sf.F] [lb/cf] [h.sf.FBtu] 1.34 9.49 20.3366 ❑ Framing Factor 0.00 0.00 11/12/04 EnergyGauge FlaCom FLCCSB v1.22 11