Loading...
HomeMy WebLinkAbout400 Lexington Green Ln 04-2558 Fire prevention Brunswick propertieSANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Ff. 32772 407 302-2520 / FAX (407) 302-2526 Plans Review Sheet Date: June 17, 2004 Business Address: 400SLexington Green Lane Occur. Ch.38 Business Business Name: Brunswick Properties. Contractor: Cyr Building & Development FAX () FAX () Ph. (407) 832-9375 Ph. () Reviewed [ ] Keviewed with comment X]Rejected [ ] Reviewed by: Timothy Robles, Fire Protection Inspector/plans Examiner . Comment: Plans reviewed as Business Occupancy. FD reserves right to require applicable code requirements if occupancy use changes. 3,600 sq ft building 1.1 Application —New 1.2 Mixed — N/A Building. Shell Only 1.3 Special Definitions — Meets F.F.P.C. - 6.1.11.1 (Record keeping/Business transactions). 1.40assification of Occupancy — Business F.F.P. C. 1.5 Classification of Hazard of Contents — Ordinary/6.2.2.2. * 1.6 Minimum Construction — N/R 2.2 Means of Egress Components — O.K. 2.3 Capacity of Egress — One person per 100 sq ft (50 or more occupants shall comply with 44' isle ways 2.4 Number of Exits — O.K. two remote exits 2.5 Arrangement of Egress — O.K., will field verify 2.6 Travel Distance — O.K. 2.7 Discharge from Exits — O.K., will field verify 1 SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772 407 302-2520 I FAX (407) 302-2526 2.8 Illumination of Means of Egress — O.K.; will field verify 2.9 Emergency Lighting — O.K.; will field verify 2.10 Marking of Means of Egress — O.K.; will field verify? 2.11 Special Features 3.1 Protection of Vertical Openings — 3.2 Protection from Hazards — N/N 3.3 Interior Finish — Class "A " 3.4 Detection, Alarm and Communications Systems Not Required 3.5 Extinguishing Requirements — as per NFPA 10 — Two (2) 3A rated fire extinguishers required in this building mounted at 36 " from floor to bottom see blue prints 3.6 Corridors — 4 Special Provisions 5 Building Services 5.1 Utilities — 5.2 HVAC — 5.3 Elevators, Escalators, Conveyors: 5.4 Rubbish Chutes, Incinerators, and Laundry Chutes — N/A Sanford City Code — Chapter 9 Fire Sprinklers: Monitoring: N/A Other: NFPA 1 3-5.1 Fire Lanes — Not Required; 3-6.1 Key Box — Not Required; will field verify, see application 3-7.1 Bldg. Address Number Posted and Legible - Required; will field verify, SIX 6") in size contrasting in color (see blueprints) 2 t 00 pfvLe, ntod' 6 re-4 o clf-r - LOfl PeC(YV-4f 04- assg